533 modules in Hardware and Environment
| Module | Description |
|---|---|
| A10-AX-MIB IPNM ✓ | MIB for managing A10 Networks AX/Thunder application delivery controllers, covering server load balancing statistics, SSL proxy metrics, DDoS counters, along with CPU and power supply status. |
| A3COM-HUAWEI-CFCARD-MIB | Handles management of CompactFlash storage cards on H3C devices, including capacity, status, and I/O error reporting. |
| A3COM-HUAWEI-ENTITY-EXT-MIB | Extends the standard ENTITY-MIB with H3C-specific hardware component attributes and operational states. |
| A3COM-HUAWEI-ENTRELATION-MIB | Describes relationships between physical and logical entities in H3C device hardware topology. |
| A3COM-HUAWEI-POWER-ETH-EXT-MIB | Extends standard Power over Ethernet (PoE) management on H3C/3Com switches with vendor-specific per-port power configuration and extended status objects. |
| A3COM-HUAWEI-TRANSCEIVER-INFO-MIB | Provides optical transceiver (SFP/XFP) monitoring on H3C/3Com devices, exposing transmit/receive power, temperature, voltage, and vendor identification data. |
| A3COM-HUWAEI-LswPERFORMANCE-MIB | Monitors LAN switch performance counters on H3C/3Com switches, including per-port throughput, buffer utilization, and switching fabric statistics. |
| AC-BOARD-MIB | Manages board-level hardware inventory and operational status on AudioCodes modular media gateways, including module type, firmware, and slot information. |
| AC-MODULAR-GATEWAY-MIB | Manages modular chassis-based AudioCodes media gateways, providing slot, blade inventory, and inter-module connectivity management. |
| AC-ModularGW-MIB | Provides management objects for AudioCodes modular gateway chassis, covering hardware module configuration, status, and inter-blade communication. |
| AcBoard | Defines board and module management object types shared across AudioCodes modular gateway product lines for hardware inventory and status reporting. |
| ACC-HUB | Manages hub port configuration on ACC/Ericsson integrated router/hub products, providing per-port enable/disable and traffic counters. |
| ACMEPACKET-ENVMON-MIB | Monitors environmental conditions including temperature, fan, and power supply status on Oracle/ACME Packet Session Border Controller appliances. |
| ACMEPACKET2-ENVMON-MIB | Supplies an updated set of environmental monitoring objects for second-generation Oracle/ACME Packet Session Border Controller appliances. |
| ADTRAN-AOS-FAN-MIB | Monitors fan status and speed on ADTRAN AOS devices for hardware environmental health management. |
| ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB | Manages over-temperature protection thresholds and shutdown actions on ADTRAN AOS devices. |
| ADTRAN-AOS-POWER | Monitors power supply status and input voltage on ADTRAN AOS devices for hardware health management. |
| ADTRAN-AOSCPU | Monitors CPU utilization and process load statistics on ADTRAN AOS platform devices. |
| ADTRAN-ATLAS-MODULE-MIB | Manages plug-in module inventory and status on ADTRAN ATLAS chassis-based multiservice access devices. |
| ADVANTECH-COMMON-MIB | Establishes common management objects and enterprise OID registration for Advantech industrial networking equipment. |
| ADVANTECH-EKI-PRONEER-MIB | Manages Advantech EKI ProNeer industrial Ethernet switch configuration, port status, and diagnostics. |
| AH-SYSTEM-MIB | Manages system-level configuration and status on Aerohive Networks wireless access points including CPU, memory, and uptime. |
| AI193TX-MIB | Manages the AI193TX network device, providing interface configuration and status monitoring objects. |
| AI194HUB-MIB | Manages the AI194 Ethernet hub, providing port status, collision statistics, and repeater management objects. |
| AI198CLC-MIB | Manages the AI198 CLC network concentrator providing port configuration and traffic statistics. |
| AISLCDISCRETE-MIB | Manages discrete I/O signal configuration and state monitoring on AI-series Serial Line Card modules. |
| AISYSCFGFAN-MIB | Monitors fan status and rotational speed on AI-series network access devices for hardware health management. |
| AISYSCFGPOWER-MIB | Monitors power supply status and input parameters on AI-series network access devices. |
| AISYSCFGTEMP-MIB | Monitors temperature sensors and thermal thresholds on AI-series network access devices. |
| ALCATEL-IND1-CHASSIS-MIB | Alcatel OmniSwitch chassis management MIB covering hardware modules, fan trays, power supplies, and physical inventory. |
| ALCATEL-IND1-HEALTH-MIB | Alcatel OmniSwitch health monitoring MIB for CPU, memory, and temperature threshold alerts and statistics. |
| ALGPOWER-v2-MIB | AGL Power Systems MIB v2 for monitoring UPS, rectifier, and power plant equipment status and alarm conditions. |
| ALPHA-CONVERTER-SYS-MIB | Alpha Technologies DC/DC converter system MIB for monitoring output voltage, current, and converter fault status. |
| ALPHA-INVERTER-SYS-MIB | Alpha Technologies inverter system MIB for monitoring DC-to-AC inverter status, output power, and fault conditions. |
| ALPHA-NOTIFICATION-MIB | Alpha Technologies notification MIB defining trap OIDs for power system alarms, events, and status changes. |
| ALPHA-RECTIFIER-SYS-MIB | Alpha Technologies rectifier system MIB for monitoring AC-to-DC rectifier module status, output, and fault alarms. |
| ALPHA-RESOURCE-MIB | Alpha Technologies resource MIB providing common textual conventions and base objects for Alpha power system MIBs. |
| AlphaPowerSystem-MIB | Alpha Technologies enterprise power system MIB providing high-level status and identity for complete power plant systems. |
| ALTIGA-HARDWARE-STATS-MIB IPNM ✓ | Cisco (formerly Altiga Networks) MIB providing hardware statistics for VPN concentrator appliances, including board-level sensor data such as voltage, temperature, and fan status. |
| ANDREW-MIB | CommScope/Andrew RF transmission equipment management for antenna and signal infrastructure. |
| APCUPS-MIB | APC/Schneider UPS management including battery status, output load, and estimated runtime. |
| APNL-MODULAR-PDU-MIB | APC/Schneider modular power distribution unit outlet control, metering, and environmental status. |
| APPN-DLUR-MIB IPNM ✓ | Defines managed objects for monitoring and controlling APPN Dependent LU Requester (DLUR) capabilities in Advanced Peer-to-Peer Networking environments. |
| Argus-MIB | Argus Technologies DC power system management including rectifier and battery status. |
| Argus-Power-System-MIB | Provides detailed monitoring of Argus Technologies power system plant equipment, alarms, and load distribution. |
| ARUBAWIRED-POWERSUPPLY-MIB | Monitors power supply unit status, input voltage, and redundancy on Aruba CX switches. |
| ARUBAWIRED-TEMPSENSOR-MIB | Reports temperature sensor readings and threshold alarms on Aruba CX switch hardware. |
| ASCEND-CHASSIS-MIB | Manages chassis hardware inventory, slot occupancy, and card status on Ascend modular platforms. |
| ASCEND-MIBREDHM-MIB | Manages redundant hardware module failover configuration on Ascend modular access equipment. |
| ASCEND-MIBREDUNDANCY-MIB | Manages system redundancy configuration and failover policies on Ascend access equipment. |
| ASCEND-MIBREDUNDANCYSTATS-MIB | Tracks redundancy-related switchover events and statistics on Ascend access equipment. |
| ASCEND-MIBSLOT-MIB | Manages physical slot and line card configuration in Ascend modular chassis equipment. |
| ASCEND-MIBSPARING-MIB | Manages spare card inventory and hot-spare replacement on Ascend modular chassis equipment. |
| ASCEND-MIBSTACK-MIB | Manages chassis stack configuration and inter-shelf connectivity on Ascend modular equipment. |
| ASCEND-MIBSTATICCONTROLLER-MIB | Manages static controller card configuration in Ascend modular chassis equipment. |
| ASCEND-MIBSTATICHSSLOT-MIB | Manages static high-speed slot card assignments in Ascend modular chassis equipment. |
| ASCEND-MIBSTATICSLOT-MIB | Manages static slot card configuration and assignment in Ascend modular chassis equipment. |
| ASCEND-MIBTHERMAL-MIB | Monitors chassis temperature sensors and configures thermal shutdown thresholds on Ascend equipment. |
| ASCEND-MULTI-SHELF-MIB | Manages multi-shelf chassis interconnection and expansion for Ascend modular access equipment. |
| ASCEND-POWER-SUPPLY-MIB | Monitors power supply status and redundancy for Ascend modular access equipment. |
| ASCEND-SPARING-MIB | Manages hot-spare card configuration and automatic replacement in Ascend modular chassis. |
| ASENTRIA-ROOT-MIB | Defines root OID and base structure for Asentria remote site monitoring and alerting equipment. |
| ASETEK-RACKCDU-SMI-V1-MIB-V16 | Manages Asetek RackCDU liquid cooling distribution unit flow, temperature, and pump status. |
| ASKEY-HARDWARE-INFORMATION-MIB | Provides hardware inventory, board version, and component status for Askey DSLAM equipment. |
| AT-BOARDS-MIB | Reports installed line-card and expansion board inventory, status, and configuration on Allied Telesis modular chassis devices. |
| AT-CHASSIS-MIB | Monitors Allied Telesis modular chassis hardware, including slot occupancy, backplane status, and power budget. |
| AT-ENVMON-MIB | Monitors environmental sensors including temperature, fan speed, and power supply status on Allied Telesis switches. |
| AT-ENVMONv2-MIB | Provides enhanced environmental monitoring with threshold alerts for temperature, fans, and PSU health on Allied Telesis platforms. |
| AT-FIBER-MONITORING-MIB | Monitors fiber optic transceiver signal levels, Tx/Rx power, and DOM thresholds on Allied Telesis SFP/SFP+ ports. |
| AT-FLASH-MIB | Monitors flash memory usage, available space, and firmware image information on Allied Telesis switches and routers. |
| AT-HHM-MIB | Manages Allied Telesis Hardware Health Monitoring, tracking component failures and proactive fault notifications. |
| AT-PLUGGABLE-DIAGNOSTICS-MIB | Reports diagnostic data for pluggable transceivers (SFP/QSFP) including temperature, voltage, and optical power on Allied Telesis devices. |
| ATS-MIB | Manages Automatic Transfer Switch (ATS) systems, reporting source availability, transfer events, and output status. |
| AVAYA-APPL-MEM-MANAGER | Monitors Avaya application memory manager, tracking heap allocation, garbage collection events, and memory pool usage. |
| AVAYA-ENTITY-MIB | Provides physical and logical entity inventory for Avaya communication equipment using RFC 2737 entity table extensions. |
| AVAYA-LOAD-MIB | Monitors CPU, memory, and system load metrics on Avaya communication servers and network equipment. |
| AVICI-BAY-MIB | Monitors Avici Systems router chassis bay occupancy, card insertion events, and per-bay power status. |
| AVICI-MEMORY-MIB | Monitors memory pool allocation, utilization, and fragmentation statistics on Avici Systems backbone router modules. |
| BAS-CARD-INFO-MIB | Reports line card inventory, firmware versions, and hardware status for the BAS CMTS chassis. |
| BAS-CHASSIS-MIB | Manages BAS CMTS chassis hardware, including slot assignments, power supplies, and chassis-level alarms. |
| BASIS-ONLINE-DIAG-MIB | Manages online diagnostic tests and results for the Cisco MGX/BASIS switch shelf hardware. |
| BASIS-RAS-DISK-MIB | Tracks disk storage status for shelf components of the Cisco MGX/BASIS RAS (Remote Access Server). |
| BASIS-SHELF-MIB | Manages shelf-level hardware inventory, slot occupancy, and power status for the Cisco MGX/BASIS voice platform. |
| BATM-MIB | Manages BATM Advanced Communications LAN switch hardware, covering port configuration, VLAN, and chassis status. |
| BAY-STACK-PETH-EXT-MIB | Extends Power over Ethernet (PoE) port power allocation and priority configuration on Avaya/Nortel ERS. |
| BAY-STACK-SFF-MIB | Reports Small Form Factor (SFP/SFP+) transceiver inventory and optical power readings on Avaya/Nortel ERS. |
| BCS-IDENT-MIB | Provides device identification and inventory objects for Belden/Hirschmann industrial Ethernet switches. |
| BCS-STATE-MIB | Monitors operational state and health status of Belden/Hirschmann BCS industrial switch components. |
| BCSI-MIB | Provides management objects for BCSI/Bel Fuse industrial Ethernet switch configuration and port status. |
| BD-MIB | Manages Extreme Networks BlackDiamond modular chassis hardware, including line cards, fabric modules, and power supplies. |
| BDCOM-MEMORY-POOL-MIB | Monitors memory pool utilization, allocation statistics, and free memory on BDCOM networking devices. |
| BDCOM-PROCESS-MIB | Monitors CPU process utilization and task scheduling statistics on BDCOM network switch/router platforms. |
| BDCOM-SYS | Provides system-level management objects including hardware inventory and software version for BDCOM devices. |
| BDFB-MIB | Manages battery distribution fuse bay (BDFB) DC power distribution, monitoring breaker states and current draw. |
| BEGEMOT-HOSTRES-MIB | Provides host resource management objects including storage, process, and device tables for FreeBSD bsnmpd. |
| BENU-CHASSIS-MIB | Covers chassis hardware management for Benu Networks broadband gateways, including card inventory and power module status. |
| BENU-HOST-MIB | Monitors host system resources including CPU, memory, and process utilization on Benu Networks platforms. |
| BENU-PLATFORM-MIB | Manages hardware platform inventory, fan, and power supply status on Benu Networks broadband gateways. |
| BESTPOWER-MIB | Manages Best Power UPS units, monitoring battery status, input/output voltage, load percentage, and fault conditions. |
| BLADETYPE2-PHYSICAL-MIB | Reports physical hardware inventory and status for HP BladeSystem Type 2 blade modules. |
| BLDG-HVAC-MIB | Monitors and manages building HVAC (heating, ventilation, and air conditioning) system parameters via SNMP. |
| BLUECOAT-HOST-RESOURCES-MIB | Reports host resource utilization (CPU, memory, storage) on Blue Coat SG proxy appliances. |
| BLUECOAT-SG-SENSOR-MIB | Reports hardware environmental sensor readings (temperature, fans, power) on Blue Coat SG proxy appliances. |
| BTI7800-EQUIPMENT-MIB | Manages hardware equipment inventory and slot configuration on BTI Systems BTI7800 optical transport nodes. |
| BTI7800-INVENTORY-MIB | Reports hardware module inventory and serial number information for BTI Systems BTI7800 network elements. |
| BTI8xx-SYSTEM-MIB | Monitors system-level hardware status and operational parameters of BTI Systems BTI8xx optical devices. |
| BUFFALO-NAS-MIB | Monitors Buffalo Technology NAS storage device volume status, disk health, and RAID array information. |
| Bull-MIB | Monitors Bull SA server hardware components including CPU, memory, storage, and environmental sensors. |
| CADANT-CMTS-EQUIPMENT-MIB | Tracks hardware components such as cards, fans, and power supplies within ARRIS/Cadant CMTS chassis equipment. |
| CADANT-HW-MEAS-MIB | Monitors hardware performance measurements including CPU, memory, and card utilization on ARRIS/Cadant CMTS platforms. |
| CARD-MIB | Manages generic hardware card (line card/module) insertion, removal, and operational state within a chassis-based network device. |
| CAREL-RITTAL-LCP-3311-MIB | Manages Carel industrial controller used in Rittal LCP 3311 data center in-row cooling units for temperature and cooling status. |
| CAREL-ug40cdz-MIB | Manages Carel UG40CDZ industrial controller for data center precision cooling including temperature, humidity, and alarm status. |
| CBS-HARDWARE-MIB | Monitors hardware inventory including chassis, power supplies, and fan status for Cisco CBS series small business switches. |
| CBS-MODULE-RESOURCES-MIB | Monitors CPU and memory resource utilization per module on Cisco CBS series small business managed switches. |
| CERENT-ENVMON-MIB | Monitors environmental conditions including temperature, voltage, and fan status on Cisco/Cerent ONS optical networking equipment. |
| CHARACTER-MIB IPNM ✓ | Defines managed objects for character stream devices and their sessions, covering terminal servers and similar character-oriented port hardware. |
| CHASSIS-MIB | Manages generic network device chassis hardware including slots, modules, power supplies, and fan assemblies. |
| CHS-MIB | Manages chassis slot and module inventory providing physical hardware configuration for chassis-based network devices. |
| CIE1000-SYSUTIL-MIB | Manages system utilities for Cisco IE1000 industrial Ethernet switches, including CPU, memory, and system health. |
| CIENA-CES-CHASSIS-MIB | Monitors chassis hardware components including slots, fans, and power supplies on Ciena CES switches. |
| CIENA-CES-MODULE-MIB | Monitors line card modules and their operational status in Ciena CES chassis-based switches. |
| CIENA-WS-BLADE-MIB | Monitors blade/line-card hardware and operational status in Ciena WaveServer chassis. |
| CIENA-WS-CHASSIS-MIB | Monitors overall chassis hardware, slots, and environmental sensors on Ciena WaveServer platforms. |
| CISCO-5800-HEALTH-MON-MIB | Monitors hardware health metrics on Cisco 5800 series access platforms. |
| CISCO-6200-MIB | Manages platform-specific hardware and operational parameters on Cisco 6200 series devices. |
| CISCO-6400-CHASSIS-MIB | Monitors chassis, card slots, and environmental status on Cisco 6400 DSL aggregation platforms. |
| CISCO-ACCESS-ENVMON-MIB | Monitors environmental conditions including temperature and voltage on Cisco access routers. |
| CISCO-ADAPTER-MIB | Manages network adapter cards and their operational parameters on Cisco server platforms. |
| CISCO-AON-STATUS-MIB | Monitors Cisco AON (Application-Oriented Networking) blade module operational status. |
| CISCO-APPLIANCE-REDUNDANCY-MIB | Manages high-availability redundancy state and failover on Cisco appliance platforms. |
| CISCO-BERT-MIB | Manages Bit Error Rate Testing (BERT) on Cisco digital interfaces for line quality verification. |
| CISCO-BITS-CLOCK-MIB | Manages BITS (Building Integrated Timing Supply) clock source selection on Cisco TDM platforms. |
| CISCO-BOOT-HWDIAGS-MIB | Monitors results of hardware diagnostics executed at boot time on Cisco platforms. |
| CISCO-C2900-MIB | Manages platform-specific hardware and software parameters on Cisco Catalyst 2900 switches. |
| CISCO-C8500-REDUNDANCY-MIB | Manages supervisor redundancy and failover on Cisco 8500 series router platforms. |
| CISCO-CAT6K-CROSSBAR-MIB | Monitors crossbar switching fabric utilization and error statistics on Cisco Catalyst 6000/6500 switches. |
| CISCO-CIDS-MIB IPNM ✓ | Provides trap definitions for Cisco Intrusion Detection System (IDS) alert and error events, and read access to sensor health information such as memory-critical status. |
| CISCO-ENERGYWISE-MIB | Manages Cisco EnergyWise power management, monitoring device power consumption, applying power budgets, and controlling endpoint power states. |
| CISCO-ENHANCED-MEMPOOL-CAPABILITY | Defines SNMP agent capability statements for Cisco Enhanced Memory Pool MIB on IOS and NX-OS platforms. |
| CISCO-ENTITY-ALARM-MIB IPNM ✓ | Supports monitoring of alarms generated by physical entities (chassis, modules, ports, power supplies) identified in the Entity-MIB entPhysicalTable. |
| CISCO-ENTITY-ASSET-CAPABILITY | Defines SNMP agent capability statements for Cisco Entity Asset MIB tracking hardware inventory and asset attributes. |
| CISCO-ENTITY-ASSET-MIB IPNM ✓ | Extends the ENTITY-MIB with asset-tracking information including part numbers, serial numbers, hardware revisions, and firmware/software identifiers for physical entities. |
| CISCO-ENTITY-CAPABILITY | Defines SNMP agent capability statements for the Cisco physical entity MIB on supported hardware platforms. |
| CISCO-ENTITY-DIAG-CAPABILITY | Defines SNMP agent capability statements for Cisco Entity Diagnostics MIB on supported hardware platforms. |
| CISCO-ENTITY-DIAG-MIB | Manages hardware diagnostics for Cisco entity components, tracking test results, diagnostic schedules, and hardware health checks. |
| CISCO-ENTITY-DISPLAY-CAPABILITY | Defines SNMP agent capability statements for Cisco Entity Display MIB managing front panel and LCD display components. |
| CISCO-ENTITY-DISPLAY-MIB | Manages front panel display and LED indicators on Cisco devices, monitoring display text, backlight status, and visual alerts. |
| CISCO-ENTITY-EXT-CAPABILITY | Defines SNMP agent capability statements for Cisco Entity Extension MIB providing additional physical component attributes. |
| CISCO-ENTITY-EXT-MIB IPNM ✓ | Extends the ENTITY-MIB entPhysicalTable with Cisco-specific information for modules that have a CPU, RAM/NVRAM, and configuration register. |
| CISCO-ENTITY-FRU-CONTROL-CAPABILITY | Defines SNMP agent capability statements for Cisco Entity FRU Control MIB managing field-replaceable unit power and reset. |
| CISCO-ENTITY-FRU-CONTROL-MIB IPNM ✓ | Monitors and configures the administrative and operational status of field-replaceable units (FRUs) such as power supplies and line cards listed in the ENTITY-MIB. |
| CISCO-ENTITY-PERFORMANCE-MIB | Monitors utilization and throughput performance metrics for Cisco physical entity components such as line cards and processors. |
| CISCO-ENTITY-PFE-MIB | Manages Cisco Packet Forwarding Engine (PFE) hardware entities, monitoring forwarding plane performance and resource utilization. |
| CISCO-ENTITY-PROVISIONING-MIB | Manages provisioning operations for Cisco hardware entities, tracking module insertion, activation, and configuration deployment. |
| CISCO-ENTITY-QFP-MIB | Monitors Cisco Quantum Flow Processor (QFP) ASIC utilization, packet processing statistics, and forwarding engine performance. |
| CISCO-ENTITY-REDUNDANCY-MIB | Manages hardware redundancy on Cisco chassis platforms, monitoring supervisor/line card switchover state and redundancy group status. |
| CISCO-ENTITY-REDUNDANCY-TC-MIB | Defines textual conventions for Cisco entity redundancy MIBs, providing data types for redundancy roles and switchover reasons. |
| CISCO-ENTITY-SENSOR-CAPABILITY | Defines SNMP agent capability statements for Cisco Entity Sensor MIB managing environmental sensors on hardware platforms. |
| CISCO-ENTITY-SENSOR-EXT-MIB | Extends standard entity sensor management with Cisco-specific threshold alarms and sensor calibration objects. |
| CISCO-ENTITY-SENSOR-HISTORY-MIB | Records historical sensor readings for Cisco physical entity sensors, enabling trend analysis of temperature, voltage, and current. |
| CISCO-ENTITY-SENSOR-MIB IPNM ✓ | Monitors sensor values and thresholds for physical entities (temperature, voltage, current, power sensors) listed in the ENTITY-MIB entPhysicalTable. |
| CISCO-ENTITY-SENSOR-RFC-CAPABILITY | Declares SNMP agent capability statements for the ENTITY-SENSOR-MIB (RFC 3433) as implemented on Cisco platforms. |
| CISCO-ENTITY-VENDORTYPE-OID-MIB | Defines Cisco-specific vendor type OIDs used to identify physical entities in the ENTITY-MIB entPhysicalVendorType field. |
| CISCO-ENVMON-CAPABILITY | Declares SNMP agent capability statements for the CISCO-ENVMON-MIB environmental monitoring implementation on various Cisco platforms. |
| CISCO-ENVMON-MIB IPNM ✓ | Monitors environmental conditions on Cisco devices including temperature, voltage, fan, and power supply status. |
| CISCO-ERM-CAPABILITY | Declares SNMP agent capability statements for the CISCO-ERM-MIB Embedded Resource Manager implementation on Cisco platforms. |
| CISCO-ERM-MIB | Provides management objects for the Cisco Embedded Resource Manager (ERM), monitoring CPU, memory, and resource thresholds on routers and switches. |
| CISCO-FABRIC-C12K-MIB | Provides management objects for monitoring the switch fabric components of the Cisco 12000 (GSR) series router chassis. |
| CISCO-FABRIC-HFR-MIB | Provides management objects for monitoring the high-speed fabric (HFR) interconnects on Cisco CRS-1 carrier routing system platforms. |
| CISCO-FABRIC-HFR-MIB-CAPABILITY | Declares SNMP agent capability statements for the CISCO-FABRIC-HFR-MIB implementation on Cisco CRS platforms. |
| CISCO-FIREPOWER-AAA-MIB | Provides management objects for authentication, authorization, and accounting (AAA) configuration and statistics on Cisco Firepower/UCS platforms. |
| CISCO-FIREPOWER-ADAPTOR-MIB | Provides management objects for monitoring Cisco UCS adapter cards including their ports, firmware, and operational state on Firepower platforms. |
| CISCO-FIREPOWER-BIOS-MIB | Provides management objects for monitoring and configuring BIOS settings and firmware versions on Cisco UCS/Firepower compute nodes. |
| CISCO-FIREPOWER-BMC-MIB | Provides management objects for the Baseboard Management Controller (BMC) on Cisco UCS/Firepower servers, including IPMI-level status. |
| CISCO-FIREPOWER-CALLHOME-MIB | Provides management objects for configuring and monitoring the Call Home feature on Cisco UCS/Firepower platforms for automated event notification. |
| CISCO-FIREPOWER-CAPABILITY-MIB | Defines capability and feature-set objects for Cisco UCS/Firepower platform components including supported hardware configurations. |
| CISCO-FIREPOWER-CHANGE-MIB | Provides management objects for tracking configuration change events and audit log entries on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-CIMCVMEDIA-MIB | Provides management objects for CIMC virtual media (KVM-mounted ISO/disk images) on Cisco UCS/Firepower compute nodes. |
| CISCO-FIREPOWER-COMM-MIB | Provides management objects for communication service settings such as SSH, Telnet, and web access on Cisco UCS/Firepower management platforms. |
| CISCO-FIREPOWER-COMPUTE-MIB | Provides management objects for monitoring compute blade and rack-server hardware resources on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-CONFIG-MIB | Provides management objects for configuration export, import, and backup operations on Cisco UCS/Firepower management platforms. |
| CISCO-FIREPOWER-DCX-MIB | Provides management objects for the Cisco UCS fabric interconnect DCX backplane switching infrastructure on Firepower platforms. |
| CISCO-FIREPOWER-DHCP-MIB | Provides management objects for DHCP client and server configuration on Cisco UCS/Firepower management plane network interfaces. |
| CISCO-FIREPOWER-DIAG-MIB | Provides management objects for diagnostic test status, health checks, and self-test results on Cisco UCS/Firepower hardware components. |
| CISCO-FIREPOWER-DOMAIN-MIB | Provides management objects for UCS domain configuration including naming, time zone settings, and fabric interconnect domain membership. |
| CISCO-FIREPOWER-DPSEC-MIB | Provides management objects for data path security policies and enforcement on Cisco UCS/Firepower platform components. |
| CISCO-FIREPOWER-EPQOS-MIB | Provides management objects for endpoint quality-of-service policy configuration on Cisco UCS/Firepower platform vNICs and adapters. |
| CISCO-FIREPOWER-ETHER-MIB | Provides management objects for Ethernet interface configuration and statistics on Cisco UCS/Firepower fabric interconnect ports. |
| CISCO-FIREPOWER-EVENT-MIB | Provides management objects for monitoring system events, event channels, and event subscriptions on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-EXTMGMT-MIB | Provides management objects for external management interface configuration on Cisco UCS/Firepower fabric interconnects. |
| CISCO-FIREPOWER-EXTPOL-MIB | Provides management objects for external policy resolution and integration settings on Cisco UCS/Firepower management platforms. |
| CISCO-FIREPOWER-EXTVMM-MIB | Provides management objects for external virtual machine manager (VMM) integration with Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-FABRIC-MIB | Provides management objects for fabric interconnect switching infrastructure, port channels, and uplinks on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-FAULT-MIB | Provides management objects for fault management including active faults, fault severity, and fault lifecycle on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-FEATURE-MIB | Provides management objects for licensed feature activation and feature package management on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-FIRMWARE-MIB | Provides management objects for firmware image management, upgrades, and version tracking on Cisco UCS/Firepower hardware components. |
| CISCO-FIREPOWER-FLOWCTRL-MIB | Provides management objects for Ethernet flow control (IEEE 802.3x pause) configuration on Cisco UCS/Firepower fabric interconnect ports. |
| CISCO-FIREPOWER-FSM-MIB | Provides management objects for the Finite State Machine (FSM) task status and progress tracking in Cisco UCS/Firepower operations. |
| CISCO-FIREPOWER-GMETA-MIB | Provides general metadata management objects for Cisco UCS/Firepower platform object model and managed object classification. |
| CISCO-FIREPOWER-HOSTIMG-MIB | Provides management objects for host OS image management and provisioning on Cisco UCS/Firepower compute nodes. |
| CISCO-FIREPOWER-IDENT-MIB | Provides management objects for system and component identity, including UUID assignment and serial number tracking on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-IMGPROV-MIB | Provides management objects for image provisioning workflows and firmware staging on Cisco UCS/Firepower hardware components. |
| CISCO-FIREPOWER-IMGSEC-MIB | Provides management objects for image security verification, signing, and integrity checking on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-IP-MIB | Provides management objects for IP address configuration and routing on management interfaces of Cisco UCS/Firepower fabric interconnects. |
| CISCO-FIREPOWER-IPPOOL-MIB | Provides management objects for IP address pool management used in Cisco UCS/Firepower service profile networking configuration. |
| CISCO-FIREPOWER-IPSEC-MIB | Provides management objects for IPsec tunnel configuration and statistics on Cisco UCS/Firepower security platforms. |
| CISCO-FIREPOWER-IQNPOOL-MIB | Provides management objects for iSCSI Qualified Name (IQN) pool configuration on Cisco UCS/Firepower platforms for iSCSI boot. |
| CISCO-FIREPOWER-LLDP-MIB | Provides management objects for Link Layer Discovery Protocol (LLDP) neighbor information and configuration on Cisco UCS/Firepower fabric interconnects. |
| CISCO-FIREPOWER-LS-MIB | Provides management objects for Logical Server (service profile) configuration and instantiation on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-LSBOOT-MIB | Provides management objects for logical server (service profile) boot order and boot policy configuration on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-LSMAINT-MIB | Provides management objects for logical server maintenance policies including firmware and BIOS update scheduling on Cisco UCS/Firepower. |
| CISCO-FIREPOWER-MACPOOL-MIB | Provides management objects for MAC address pool management used in vNIC configuration on Cisco UCS/Firepower service profiles. |
| CISCO-FIREPOWER-MAPPINGS-MIB | Provides management objects for device-to-profile mapping and logical-to-physical resource associations on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-MEMORY-MIB | Provides management objects for monitoring memory DIMM inventory, speed, capacity, and error statistics on Cisco UCS/Firepower compute nodes. |
| CISCO-FIREPOWER-MGMT-MIB | Provides management objects for UCS Manager management plane configuration including roles, users, and admin settings on Cisco UCS/Firepower. |
| CISCO-FIREPOWER-MIB | Top-level Cisco UCS/Firepower MIB providing root OID registration and overview objects for the entire Firepower/UCS SNMP management framework. |
| CISCO-FIREPOWER-NETWORK-MIB | Provides management objects for network connectivity configuration including VLANs, uplinks, and LAN connectivity on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-NFS-MIB | Provides management objects for NFS mount configuration and storage access on Cisco UCS/Firepower management and compute nodes. |
| CISCO-FIREPOWER-NOTIFS-MIB | Defines SNMP notification (trap) objects for alerting on faults, events, and state changes on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-NWCTRL-MIB | Provides management objects for network control policy configuration governing adapter behavior on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-OBSERVE-MIB | Provides management objects for monitoring observations, threshold events, and trending data on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-ORG-MIB | Provides management objects for hierarchical organization (tenant) management and resource delegation on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-OS-MIB | Provides management objects for monitoring operating system configuration and status on Cisco UCS/Firepower managed compute nodes. |
| CISCO-FIREPOWER-PCI-MIB | Provides management objects for monitoring PCI bus device inventory and PCIe adapter status on Cisco UCS/Firepower compute nodes. |
| CISCO-FIREPOWER-PKI-MIB | Provides management objects for PKI certificate and key pair management on Cisco UCS/Firepower management platforms. |
| CISCO-FIREPOWER-POLICY-MIB | Provides management objects for policy definition, inheritance, and enforcement across Cisco UCS/Firepower service profiles and pools. |
| CISCO-FIREPOWER-PORT-MIB | Provides management objects for physical port configuration, state monitoring, and statistics on Cisco UCS/Firepower fabric interconnect hardware. |
| CISCO-FIREPOWER-POWER-MIB | Provides management objects for power supply inventory, power budget, and redundancy management on Cisco UCS/Firepower chassis and fabric interconnects. |
| CISCO-FIREPOWER-PROC-MIB | Provides management objects for monitoring running processes, CPU utilization, and process health on Cisco UCS/Firepower management nodes. |
| CISCO-FIREPOWER-PROCESSOR-MIB | Supplies management objects to track CPU processor inventory, speed, core count, and status across Cisco UCS/Firepower compute blades. |
| CISCO-FIREPOWER-QOSCLASS-MIB | Provides management objects for QoS class map definition and priority configuration on Cisco UCS/Firepower fabric interconnect platforms. |
| CISCO-FIREPOWER-QUERYRESULT-MIB | Provides management objects for query result set management used by Cisco UCS/Firepower SNMP data retrieval operations. |
| CISCO-FIREPOWER-SM-MIB | Provides management objects for service module configuration and status on Cisco UCS/Firepower chassis service module slots. |
| CISCO-FIREPOWER-SOL-MIB | Provides management objects for Serial over LAN (SoL) console configuration and access on Cisco UCS/Firepower compute nodes. |
| CISCO-FIREPOWER-STATS-MIB | Provides management objects for statistical data collection policies and counters across Cisco UCS/Firepower platform components. |
| CISCO-FIREPOWER-STORAGE-MIB | Provides management objects for local storage controller, disk inventory, RAID configuration, and storage health on Cisco UCS/Firepower compute nodes. |
| CISCO-FIREPOWER-SYSDEBUG-MIB | Provides management objects for system debug, core dump configuration, and troubleshooting settings on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-SYSFILE-MIB | Provides management objects for system file management, log rotation, and file system monitoring on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-TC-MIB | Defines textual conventions used across the Cisco UCS/Firepower SNMP MIB suite for standardized data type definitions. |
| CISCO-FIREPOWER-TOP-MIB | Provides the top-level managed object class hierarchy and root object registration for the Cisco UCS/Firepower SNMP MIB framework. |
| CISCO-FIREPOWER-TRIG-MIB | Provides management objects for trigger-based monitoring and threshold alerting on Cisco UCS/Firepower platform statistics. |
| CISCO-FIREPOWER-UUIDPOOL-MIB | Provides management objects for UUID pool management used in server identity assignment on Cisco UCS/Firepower service profiles. |
| CISCO-FIREPOWER-VERSION-MIB | Provides management objects for system version tracking, software version strings, and release metadata on Cisco UCS/Firepower platforms. |
| CISCO-FIREPOWER-VM-MIB | Provides management objects for virtual machine integration and VM inventory visibility on Cisco UCS/Firepower hypervisor-connected platforms. |
| CISCO-FIREPOWER-VNIC-MIB | Provides management objects for virtual NIC (vNIC) template, instantiation, and statistics on Cisco UCS/Firepower service profiles. |
| CISCO-FLASH-CAPABILITY | Declares SNMP agent capability statements for the CISCO-FLASH-MIB flash storage management implementation on Cisco platforms. |
| CISCO-HW-MODULE-CONTROL-CAPABILITY | Declares SNMP agent capability statements for the CISCO-HW-MODULE-CONTROL-MIB hardware module power management on Cisco platforms. |
| CISCO-HW-MODULE-CONTROL-MIB | Provides management objects for controlling power-on, power-off, and reset operations for hardware modules in Cisco router and switch chassis. |
| CISCO-INTERFACE-XCVR-MONITOR-MIB | Monitors SFP, XFP, and QSFP optical transceiver digital optical monitoring (DOM) parameters. |
| CISCO-L4L7MODULE-REDUNDANCY-CAPABILITY | Declares agent capability for Cisco Layer 4-7 service module redundancy MIB. |
| CISCO-L4L7MODULE-REDUNDANCY-MIB | Manages redundancy and failover configuration for Cisco Layer 4-7 service modules. |
| CISCO-L4L7MODULE-RESOURCE-LIMIT-CAPABILITY | Declares agent capability for Cisco Layer 4-7 module resource limit MIB. |
| CISCO-L4L7MODULE-RESOURCE-LIMIT-MIB | Manages resource limits (connections, bandwidth, memory) for Cisco Layer 4-7 service modules. |
| CISCO-LWAPP-HA-MIB | Manages LWAPP/CAPWAP wireless LAN controller high availability, SSO, and redundancy state. |
| CISCO-MEMORY-POOL-CAPABILITY | Declares SNMP agent capabilities for memory pool utilization monitoring on Cisco routing and switching platforms. |
| CISCO-MGX82XX-CARD-FEATURE-MIB | Manages feature configuration and capabilities for line cards in Cisco MGX 8200 series WAN switches. |
| CISCO-MGX82XX-DSX1-MIB | Manages DS1/T1 interface configuration and performance statistics on Cisco MGX 8200 WAN switch line cards. |
| CISCO-MGX82XX-DSX3-BERT-MIB | Manages DS3 Bit Error Rate Testing (BERT) operations on Cisco MGX 8200 series WAN switching platforms. |
| CISCO-MGX82XX-DSX3-MIB | Manages DS3/T3 interface configuration and performance statistics on Cisco MGX 8200 WAN switch line cards. |
| CISCO-MGX82XX-ENVMON-MIB | Monitors environmental conditions including temperature, voltage, and fan status on Cisco MGX 8200 chassis. |
| CISCO-MGX82XX-MODULE-RSRC-PART-MIB | Manages module resource partitioning for bandwidth and connection allocation on Cisco MGX 8200 platforms. |
| CISCO-MGX82XX-PXM-CLOCK-MIB | Manages PXM clock source configuration and synchronization timing on Cisco MGX 8200 WAN switch chassis. |
| CISCO-MGX82XX-RPM-CONN-MIB | Manages RPM (Route Processor Module) connection configuration on Cisco MGX 8200 WAN switching platforms. |
| CISCO-MGX82XX-RPM-RSRC-PART-MIB | Manages RPM resource partitioning for ATM and Frame Relay connections on Cisco MGX 8200 platforms. |
| CISCO-MGX82XX-RPM-SUBIF-MIB | Configures RPM subinterfaces and reports their statistics on Cisco MGX 8200 series WAN switching platforms. |
| CISCO-MGX82XX-SONET-MIB | Manages SONET interface configuration and performance monitoring on Cisco MGX 8200 WAN switch line cards. |
| CISCO-MGX82XX-VIRTUAL-PORT-MIB | Manages virtual port configuration for ATM and Frame Relay connections on Cisco MGX 8200 WAN switches. |
| CISCO-MGX8800-IF-MAPPING-CAPABILITY | Declares SNMP agent capabilities for interface mapping management on Cisco MGX 8800 WAN switching platforms. |
| CISCO-MGX8800-IF-MAPPING-MIB | Manages interface-to-slot/port mapping configuration on Cisco MGX 8800 series WAN switching platforms. |
| CISCO-MODULE-AUTO-SHUTDOWN-CAPABILITY | Declares SNMP agent capabilities for automatic module shutdown on Cisco modular routing and switching platforms. |
| CISCO-MODULE-AUTO-SHUTDOWN-MIB | Manages automatic shutdown of faulty line card modules to protect chassis integrity on Cisco modular platforms. |
| CISCO-MODULE-VIRTUALIZATION-CAPABILITY | Declares SNMP agent capabilities for module virtualization on Cisco modular routing and switching platforms. |
| CISCO-MODULE-VIRTUALIZATION-MIB | Manages virtual partitioning of physical line card modules into logical instances on Cisco modular platforms. |
| CISCO-MSATA-MIB | Manages mSATA solid-state drive storage modules installed in Cisco routers for logging and data storage. |
| CISCO-POE-PD-MIB | Manages Power over Ethernet powered device (PD) power negotiation and consumption on Cisco PoE endpoints. |
| CISCO-POWER-ETHERNET-CAPABILITY | Declares agent capabilities for Power over Ethernet (PoE) management including port power delivery and budget control. |
| CISCO-POWER-ETHERNET-EXT-CAPABILITY | Declares SNMP agent capabilities for Power over Ethernet extensions on Cisco PoE switching platforms. |
| CISCO-POWER-ETHERNET-EXT-MIB | Extends PoE management with Cisco-specific power budget, class, and per-port allocation statistics. |
| CISCO-PROCESS-CAPABILITY | Declares agent capabilities for process and CPU utilization monitoring on Cisco IOS and NX-OS platforms. |
| CISCO-PROCESS-MIB IPNM ✓ | Monitors CPU process utilization, memory consumption, and runtime statistics on Cisco routing platforms. |
| CISCO-PRODUCTS-MIB IPNM ✓ | Defines sysObjectID values assigned to Cisco hardware platforms, serving as the central registry for SNMP-based product identification. |
| CISCO-PSA-MICROCODE-MIB | Handles microcode version tracking and loading for Parallel Side-A processors on Cisco modular platforms. |
| CISCO-SEU-MITIGATION-MIB | Monitors Single Event Upset (SEU) hardware error detection and mitigation due to cosmic ray radiation on Cisco platforms. |
| CISCO-SIBU-FLASH-MIB | Manages flash memory storage and firmware image inventory on Cisco SIBU SMB switches such as Catalyst 1900. |
| CISCO-STACK-CAPABILITY | Declares agent capabilities for switch stacking management on Cisco Catalyst and similar stackable switch platforms. |
| CISCO-STACKMAKER-MIB | Manages Cisco StackMaker proprietary stacking protocol providing configuration and status for stacked switch clusters. |
| CISCO-STACKWISE-MIB | Manages Cisco StackWise switch stacking technology including stack topology, port roles, and member switch status. |
| CISCO-SWITCH-ENGINE-CAPABILITY | Declares agent capabilities for switch engine ASIC management on Cisco Catalyst hardware platforms. |
| CISCO-SWITCH-ENGINE-MIB | Monitors Cisco switch engine fabric utilization, forwarding rates, and switching ASIC statistics. |
| CISCO-SWITCH-FABRIC-CAPABILITY | Declares agent capabilities for switch fabric management including crossbar and backplane configuration. |
| CISCO-SWITCH-FABRIC-MIB | Manages switch fabric components including crossbar switching, backplane utilization, and fabric health monitoring. |
| CISCO-SWITCH-HARDWARE-CAPACITY-CAPABILITY | Declares agent capabilities for monitoring switch hardware resource capacity including TCAM and table utilization. |
| CISCO-SWITCH-HARDWARE-CAPACITY-MIB | Monitors switch hardware resource capacity including TCAM entries, MAC tables, and ASIC resource utilization. |
| CISCO-SWITCH-STATS-CAPABILITY | Declares agent capabilities for switch port and ASIC statistics collection on Cisco Catalyst platforms. |
| CISCO-SWITCH-STATS-MIB | Supplies detailed port- and ASIC-level traffic statistics, including error and throughput counters, for Cisco Catalyst switches. |
| CISCO-SYSTEM-EXT-CAPABILITY | Declares agent capabilities for Cisco system extension features including chassis, memory, and boot information. |
| CISCO-TEMPERATURE-MIB | Monitors device temperature sensors providing current readings, thresholds, and thermal alarm status on Cisco hardware. |
| CISCO-UNIFIED-COMPUTING-CONTROLLER-MIB | Manages Cisco UCS Manager controller providing fabric interconnect configuration, policy, and operational state monitoring. |
| CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB | Monitors Cisco UCS equipment inventory including chassis, blade servers, fabric interconnects, and FEX modules. |
| CISCO-UNIFIED-COMPUTING-MIB | Provides top-level management for Cisco Unified Computing System (UCS) including blade servers, fabric, and service profiles. |
| CISCO-UNIFIED-COMPUTING-PROC-MIB | Monitors Cisco UCS server processor inventory, core counts, speed, and operational status within UCS domains. |
| CISCO-UNIFIED-COMPUTING-VERSION-MIB | Provides version information for Cisco UCS Manager software components and firmware across UCS infrastructure. |
| CISCO-VOICE-CARD-MIB | Manages Cisco voice hardware cards installed in routers, including DSP resources and card status. |
| CISCO-WAN-MODULE-MIB | Manages Cisco WAN service module cards including configuration, status, and reset operations on MGX. |
| CISCO-WAN-SRM-BERT-MIB | Manages Cisco WAN SRM (Service Resource Module) BERT (Bit Error Rate Test) for T1/E1 testing. |
| CISCO-WAN-SRM-MIB | Manages Cisco WAN Service Resource Module (SRM) configuration for T1/E1 port provisioning on MGX. |
| CISCOSB-EEE-MIB | Manages Cisco Small Business Energy Efficient Ethernet (EEE/IEEE 802.3az) power saving on switch ports. |
| CISCOSB-GREEN-MIB | Manages Cisco Small Business green (energy saving) features including port power-down and LED control. |
| CISCOSB-HWENVIROMENT | Monitors hardware environmental conditions (temperature sensors, fans, power supplies) on Cisco Small Business switches, defining environmental state objects. |
| CISCOSB-Physicaldescription-MIB IPNM ✓ | Defines managed objects for physical description and environmental parameters of Cisco Small Business devices, including unit parameters and fan monitoring. |
| CISCOSB-POE-MIB | Manages Cisco Small Business Power over Ethernet (PoE) port configuration, budgets, and power statistics. |
| CISCOSB-RLINVENTORYENT-MIB | Manages Cisco Small Business hardware inventory including chassis, modules, and component entity data. |
| CISCOSB-SENSORENTMIB | Manages Cisco Small Business physical sensor entity data including temperature and voltage readings. |
| CLAB-UPS-MIB | Monitors Uninterruptible Power Supply (UPS) status and battery health for CableLabs-defined DOCSIS equipment. |
| CM-SYSTEM-MIB | Monitors system-level hardware identity, software versions, and alarms for Ceragon microwave equipment. |
| CMC-MIB | Manages Rittal Cabinet Management Controller (CMC) environmental sensors including temperature and humidity. |
| COLUBRIS-SENSOR-MIB | Monitors environmental sensor readings such as temperature from Colubris/HP wireless access points. |
| CONEL-IO-MIB | Manages digital and analog I/O port states and values on Conel industrial IoT routers. |
| CONTROLBOX-TH332-MIB | Monitors temperature and humidity sensor readings from the ControlBox TH332 environmental monitor. |
| CPQ-TRAPS-MIB | Defines SNMP trap notifications for Compaq/HP ProLiant server hardware faults and alerts. |
| CPQAPPLIANCE-MIB | Manages Compaq/HP server appliance system status, firmware, and subsystem health objects. |
| CPQCMC-MIB | Manages Compaq/HP Consolidated Management Console (CMC) blade server chassis and module objects. |
| CPQDCEO-MIB | Manages Compaq/HP data center energy optimization settings and power consumption reporting. |
| CPQDSCCS-MIB | Manages Compaq/HP storage controller cache and battery status for ProLiant servers. |
| CPQEXTERNAL-MIB | Provides management objects for Compaq/HP external storage enclosures and attached peripherals. |
| CPQGEN-MIB | Provides generic management objects for Compaq/HP ProLiant server general system information. |
| CPQHLTH-MIB IPNM ✓ | Compaq/HPE Server Health MIB monitoring thermal sensors, fans, power supplies, ASR status, POST error logging, and overall server health condition on ProLiant servers. |
| CPQHOST-MIB | MIB from Compaq (now HPE) covering host operating system monitoring on ProLiant servers, including system parameter management, client identification, and trap delivery. |
| CPQIDA-MIB IPNM ✓ | Compaq/HPE Intelligent Drive Array MIB for monitoring RAID controllers, logical drives, physical drives, and array accelerator (cache) status on ProLiant storage subsystems. |
| CPQIDE-MIB | Monitors Compaq/HP IDE/ATA disk drive status and failure prediction on ProLiant servers. |
| CPQKVM-MIB | Manages Compaq/HP KVM switch port mapping and connected server console access objects. |
| CPQPOWER-MIB | Monitors Compaq/HP ProLiant server power subsystem including power supplies, redundancy status, and power consumption. |
| CPQRACK-MIB | Manages HP ProLiant rack and enclosure components including rack topology, enclosure slots, and blade interconnects. |
| CPQRECOV-MIB | Monitors HP ProLiant Automatic Server Recovery (ASR) agent status, recovery actions, and fault detection thresholds. |
| CPQRPM-MIB | Manages HP ProLiant Remote Power Management including remote power switching and outlet configuration. |
| CPQSANAPP-MIB | Monitors HP StorageWorks SAN application status, storage array connections, and management agent health. |
| CPQSANEVENT-MIB | Provides HP StorageWorks SAN event notifications for storage array faults, path failures, and configuration changes. |
| CPQSASSWITCH-MIB | Manages HP SAS (Serial Attached SCSI) switch interconnects, port status, and fabric configuration for ProLiant servers. |
| CPQSCSI-MIB | Monitors HP ProLiant SCSI and Smart Array controller status, logical drives, physical drives, and controller errors. |
| CPQSERVICE-MIB | Tracks the status of HP ProLiant service and management agents, including Insight Manager agent health and overall service availability. |
| CPQSINFO-MIB | Compaq/HP Insight Management MIB for server system information, exposing hardware asset details, serial numbers, system board data, and overall server status. |
| CPQSM2-MIB | Manages HP iLO (Integrated Lights-Out) remote management board for out-of-band server control and monitoring. |
| CPQSRVMN-MIB | Provides HP ProLiant server management data including system inventory, software versions, and overall server health. |
| CPQSTDEQ-MIB | Monitors standard HP ProLiant server equipment including processors, memory DIMMs, and system board components. |
| CPQSTSYS-MIB | Manages HP StorageWorks storage system arrays including RAID configuration, logical volumes, and physical disk status. |
| CPQSWCC-MIB | Manages HP StorageWorks Command Console providing storage resource configuration and monitoring capabilities. |
| CPQTHRSH-MIB | Configures HP ProLiant performance monitoring thresholds for CPU, memory, disk, and network utilization alerting. |
| CPQUPS-MIB | Monitors HP ProLiant uninterruptible power supply status including battery level, input voltage, and UPS fault conditions. |
| CPQWCRM-MIB | Manages HP ProLiant Wide-Connect Resource Manager for cluster resource monitoring and failover management. |
| CPS-MIB | Monitors CyberPower Systems UPS devices including input/output power, battery status, and load percentage. |
| CPS6000-MIB | Manages CyberPower 6000-series UPS units providing power quality metrics, battery health, and alarm notifications. |
| CRI-SERVER-MIB | Monitors CRI server platform hardware status, system resources, and operational health indicators. |
| CROSSBEAM-SYSTEMS-MIB | Manages Crossbeam Systems network security platform providing chassis, module, and application blade monitoring. |
| CT-CHASSIS-MIB | Monitors Cabletron/Enterasys chassis hardware components including modules, power supplies, and fan status. |
| CT-CMMPHYS-MIB | Manages Cabletron CMM (Connectivity Management Module) physical layer parameters and port statistics. |
| CT-CONTAINER-MIB | Manages Cabletron/Enterasys container and slot configuration for modular chassis physical inventory. |
| CT-FLASH-MIB | Manages Cabletron/Enterasys flash memory storage including file system status, available space, and firmware images. |
| CT-HSIMPHYS-MIB | Monitors Cabletron HSIM (High Speed Interface Module) physical layer parameters, signal levels, and port state. |
| CT-PIC-MIB | Manages Cabletron PIC (Port Interface Card) hardware configuration, port assignments, and physical inventory. |
| CTRON-CHASSIS-MIB | Manages Cabletron chassis hardware inventory, slot assignments, module types, and overall chassis health. |
| CTRON-ENVIRONMENT-MIB | Monitors Cabletron environmental sensors including temperature, voltage, fan speed, and power supply status. |
| CTRON-FRONTPANEL-MIB | Monitors Cabletron front panel LED indicators, button states, and visual alarm status for chassis management. |
| CTRON-POWER-SUPPLY-MIB | Monitors Cabletron power supply units including operational state, redundancy status, and fault conditions. |
| CTRON-SSR-HARDWARE-MIB | Monitors Cabletron SSR hardware components including line cards, power supplies, and fan tray status. |
| CTRON-UPS-MIB | Monitors Cabletron-attached UPS devices including battery status, input power, and power failure notifications. |
| CTSMTMIB-MIB | Manages Cabletron SMT (Station Management) for FDDI ring management, neighbor notification, and ring monitoring. |
| CUMULUS-RESOURCES-MIB | Monitors Cumulus Linux ASIC resource utilization including ACL, route, MAC, and forwarding table usage. |
| CXGIM-MIB | Manages Aastra GIM (Generic Interface Module) hardware configuration, port assignments, and module status. |
| CYAN-FAN-MIB | Manages fan tray status and environmental monitoring for Cyan optical networking equipment. |
| DCS3FRU-MIB | Manages field-replaceable unit (FRU) inventory and status for DCS3 chassis systems. |
| DCS3RMT-MIB | Manages remote management access and control for DCS3 chassis platforms. |
| DECHUB90-MIB | Manages the DEC HUB 90 series modular hub chassis, modules, and ports. |
| DECHUB900-CHASSIS-MIB-V3-0 | Manages DEC HUB 900 chassis hardware components, power supplies, and backplane configuration. |
| DELL-ASF-MIB | Manages Alert Standards Format (ASF) platform events and alerts for Dell server hardware. |
| DELL-MM-MIB | Manages Dell Modular Management chassis components, blades, and enclosure resources. |
| DELL-NETWORKING-CHASSIS-MIB | Manages chassis hardware components, line cards, and system inventory for Dell Networking equipment. |
| DELL-NETWORKING-SYSTEM-COMPONENT-MIB | Manages system-level hardware components including fans, power supplies, and temperature for Dell Networking. |
| DELLBASEBOARDMIF-MIB | Manages Dell server baseboard hardware inventory and component status via MIF data. |
| DELLEMC-OS10-CHASSIS-MIB | Manages chassis components, inventory, and hardware status for Dell EMC OS10 networking equipment. |
| DELLLOCALRESPONSEAGENTMIF-MIB | Manages Dell Local Response Agent alerts, thresholds, and automated response actions for servers. |
| DELLRCSG2-TRAP-MIB | Defines trap notifications and alert events for Dell RCSG2 chassis management. |
| DEVHW-MIB | Manages hardware component inventory, status, and environmental monitoring for network devices. |
| DGPPDU-MIB | Manages power distribution unit (PDU) configuration and outlet monitoring for DGP equipment. |
| DGPRPM-MIB | Manages remote power management and outlet control for DGP power management equipment. |
| DGPUPS-MIB | Manages DGP UPS system battery status, power metrics, and alarm notifications. |
| EdgeSwitch-BOXSERVICES-PRIVATE-MIB IPNM ✓ | A Ubiquiti private MIB covering EdgeSwitch box services, used to track chassis environmental data such as temperature readings, fan status, and power supply state. |
| EdgeSwitch-INVENTORY-MIB | Ubiquiti's EdgeSwitch inventory MIB, tracking hardware components, firmware versions, and physical device details. |
| ENTERASYS-ENTITY-SENSOR-MIB-EXT-MIB | Extreme/Enterasys Networks extension to the Entity Sensor MIB providing SFP optical sensor monitoring objects. |
| ENTITY-MIB IPNM ✓ | Provides management information about the physical and logical components of a system, including hardware inventory such as fans, sensors, modules, serial numbers, and model information. |
| ENTITY-SENSOR-MIB IPNM ✓ | An extension of ENTITY-MIB adding support for physical sensors on networking equipment, so environmental parameters like temperature, voltage, and fan speed can be monitored. |
| ENTITY-STATE-MIB IPNM ✓ | Defines managed objects extending the Entity MIB to provide administrative, operational, and standby state information for physical entities. |
| ENTITY-STATE-TC-MIB IPNM ✓ | Defines textual conventions for representing entity states including administrative, operational, usage, alarm, and standby states of physical entities. |
| EQUIPMENT-COMMON-MIB | DragonWave Inc. equipment common MIB providing alarm notification log and active alarm list management objects. |
| EQUIPMENT-MIB | D-Link/proprietary equipment management MIB providing chassis, fan, power supply, stacking, and port hardware status objects. |
| ETHER-CHIPSET-MIB IPNM ✓ | Defines registered OBJECT IDENTIFIER values for identifying Ethernet chipsets, used by the EtherLike-MIB to identify MAC hardware. |
| EXTREME-ENTITY-MIB | Extreme Networks MIB providing physical and logical entity inventory for ExtremeXOS-based switches, extending RFC 2737 entity concepts. |
| EXTREME-HARDWARE-MIB | Extreme Networks MIB providing hardware inventory, environmental sensor, and chassis component status for Extreme switches and routers. |
| F10-C-SERIES-CHASSIS-MIB | Dell Force10 MIB for the C-Series chassis hardware inventory including line cards, fans, and power supplies. |
| F10-CHASSIS-MIB | Dell Force10 MIB providing chassis-level hardware inventory and environmental monitoring for Force10 switching platforms. |
| F10-M-SERIES-CHASSIS-MIB | Dell Force10 MIB for the M-Series blade chassis hardware components including fabric modules and blade inventory. |
| F10-S-SERIES-CHASSIS-MIB | Dell Force10 MIB for S-Series fixed-configuration switch chassis inventory including power, fan, and module components. |
| F10-Z-SERIES-CHASSIS-MIB | Dell Force10 MIB for the Z-Series high-density 10GbE/40GbE chassis hardware inventory and environmental sensors. |
| FAN-MIB | Generic MIB for monitoring fan unit status, speed, and failure conditions in network equipment and server hardware. |
| FANS-POWER-MIB | MIB for monitoring fan and power supply unit status including operational state and failure alarms in chassis-based equipment. |
| FASTPATH-BOXSERVICES-PRIVATE-MIB | Broadcom FastPath (DNOS/FASTPATH) MIB for box-level services including temperature, fans, and power supply monitoring. |
| FASTPATH-INVENTORY-MIB | Broadcom FastPath MIB for hardware inventory including modules, power supplies, and fans on FastPath-based network equipment. |
| FD-SYSTEM-MIB | C-Data FD-series system-level MIB for device identity, firmware version, and system configuration on FD-platform OLTs. |
| FH800u-MIB | Vendor-specific MIB for FH800u series network equipment providing device management and interface status monitoring. |
| FORCE10-MONITORING-MIB | Dell Force10 Networks system monitoring MIB providing environmental sensor, fan, power supply, and temperature objects for chassis health. |
| FORCE10-SYSTEM-COMPONENT-MIB | Dell Force10 Networks system component MIB providing inventory and status objects for chassis modules, line cards, and FPGAs. |
| FOUNDRY-SN-AGENT-MIB IPNM ✓ | Brocade/Foundry Networks agent MIB for managing and monitoring ServerIron and NetIron chassis devices, including hardware inventory, CPU/memory utilization, temperature, and system configuration. |
| G6-HARDWARE-MIB | MICROSENS G6 switch MIB for hardware inventory, sensor status, fan speed, and temperature monitoring. |
| GEIST-IMD-MIB | Geist Intelligent Module Device MIB for monitoring data center environmental sensors including temperature and humidity. |
| GEIST-V4-MIB | Geist V4 platform MIB for monitoring rack PDU power consumption, environmental sensors, and outlet control. |
| GEPARALLELUPS-MIB | GE Digital Energy MIB for parallel-configured UPS systems monitoring combined power output and redundancy status. |
| GESINGLEUPS-MIB | GE Digital Energy MIB for single UPS system monitoring covering battery, input/output power, and alarm status. |
| H3C-CATV-TRANSCEIVER-MIB | H3C MIB for monitoring CATV optical transceiver parameters including optical power levels and signal quality. |
| H3C-CFCARD-MIB | H3C MIB for managing CompactFlash (CF) card storage devices in network equipment including status and capacity. |
| H3C-ENTITY-EXT-MIB | H3C MIB extending the standard entity MIB with additional physical component attributes and operational states. |
| H3C-ENTITY-VENDORTYPE-OID-MIB | H3C MIB defining OID assignments for vendor-specific entity physical types in H3C network equipment. |
| H3C-ENTRELATION-MIB | H3C MIB describing containment and connectivity relationships between physical and logical entities in the device. |
| H3C-FLASH-MAN-MIB | H3C MIB for flash storage management on network devices including file operations and storage capacity. |
| H3C-PU-MAN-MIB | H3C MIB for processing unit management monitoring CPU modules, their status, and resource utilization. |
| H3C-TRANSCEIVER-INFO-MIB | H3C MIB for optical transceiver diagnostics reporting SFP/XFP module parameters such as temperature and optical power. |
| HAWK-I2-MIB | Monitors environmental and power parameters for Sinetica Hawk-I2 intelligent monitoring units in data centers. |
| HEALTH-MONITOR-SUNMANAGEMENTCENTER-MIB | Provides health monitoring objects for Sun Management Center, tracking component status and resource utilization on Sun servers. |
| HH3C-CFCARD-MIB | Manages CompactFlash card storage devices on H3C routers and switches, including capacity and access status. |
| HH3C-DISK-MIB | Manages disk storage devices on H3C platforms, providing capacity, health status, and I/O performance objects. |
| HH3C-DSP-MIB | Manages Digital Signal Processor (DSP) resources and voice channel capacity on H3C voice gateway modules. |
| HH3C-ENTITY-EXT-MIB IPNM ✓ | Extends entity management on H3C/HH3C network devices with tables for CPU usage, memory usage, power information, and voltage sensor readings. |
| HH3C-ENTITY-VENDORTYPE-OID-MIB | Defines H3C vendor-specific entity type OIDs for hardware components reported in the ENTITY-MIB. |
| HH3C-ENTRELATION-MIB | Tracks relationships between physical and logical entities within H3C device hardware inventory. |
| HH3C-FLASH-MAN-MIB | Manages flash storage devices on H3C platforms, providing file system operations and capacity monitoring. |
| HH3C-LOGIC-VOLUME-MIB | Manages logical storage volumes on H3C platforms including RAID groups and volume health status. |
| HH3C-LswDEVM-MIB | Manages device module inventory, slot states, and hardware component events on H3C Layer 2 switch platforms. |
| HH3C-REDUNDANCY-POWER-MIB | HH3C MIB for redundant power supply management monitoring dual PSU status and failover on H3C chassis. |
| HH3C-RS485-MIB | HH3C MIB for RS-485 serial interface management on H3C devices with RS-485 console or sensor ports. |
| HH3C-TRANSCEIVER-INFO-MIB | HH3C MIB for optical transceiver information providing DOM/SFP module diagnostics on H3C switch ports. |
| HIMOINSAv14-MIB | HIMOINS industrial monitoring SNMP MIB version 14 for environmental and equipment sensor monitoring in industrial facilities. |
| HM2-DIAGNOSTIC-MIB | Hirschmann HiOS (HM2) diagnostics MIB for cable testing, port diagnostics, and hardware fault detection. |
| HM2-IOMODULE-MIB | Hirschmann HiOS (HM2) I/O module MIB for managing plug-in I/O expansion modules on Hirschmann industrial switches. |
| HM2-PWRMGMT-MIB | Hirschmann HiOS (HM2) power management MIB for monitoring power supply units and consumption on Hirschmann switches. |
| HMIOMODULE-SNMP-MIB | Hirschmann I/O module SNMP MIB for monitoring and controlling plug-in I/O expansion modules in Hirschmann industrial switches. |
| HOST-RESOURCES-MIB IPNM ✓ | Covers managed objects describing host computer systems, including storage, installed software, running processes, and device information. |
| HOST-RESOURCES-TYPES IPNM ✓ | Registers type definitions for storage types, device types, and file system types used as values in the Host Resources MIB. |
| HP-ENTITY-MIB | HP ProCurve extension of the standard ENTITY-MIB providing enhanced physical component inventory for HP chassis-based devices. |
| HP-ENTITY-POWER-MIB | HP SNMP MIB for monitoring and managing power consumption and state of physical entities in HP networking hardware. |
| HP-ICF-CHASSIS IPNM ✓ | Describes chassis-level hardware for HP ProCurve/Aruba switches, including sensor readings (temperature, fans, power), slot mapping, and entity configuration. |
| HP-ICF-DEVICE-MONITOR-MIB | HP ICF SNMP MIB for device health monitoring including CPU, memory, and environment threshold alerts on HP ProCurve switches. |
| HP-ICF-SLOT-STATS-MIB | HP ICF SNMP MIB for per-slot traffic statistics and performance counters on modular HP ProCurve chassis switches. |
| HP-ICF-TRANSCEIVER-MIB | HP ICF SNMP MIB for optical transceiver diagnostics including DOM data such as temperature, voltage, and optical power on HP ProCurve switches. |
| HP-LASERJET-COMMON-MIB IPNM ✓ | Monitors HP LaserJet printer hardware status and performance counters via SNMP, covering consumable levels, print engine state, and device health across LaserJet models. |
| HP-MEMPROC-MIB | HP SNMP MIB for memory and processor utilization monitoring on HP networking devices including CPU load and memory pool statistics. |
| HP-SYSTEM-MIB | HP SNMP MIB for system-level management including CPU, memory, temperature, and fan status on HP networking products. |
| HP700RX-MIB | SNMP MIB for the HP 700/RX X terminal providing management objects for monitor, memory, serial port, and network configuration. |
| HPHOTSWAP2SUBSYSTEM-MIB | HP SNMP MIB for hot-swap subsystem management monitoring hot-pluggable component state and status in HP server systems. |
| HPIPF02TRAP-MIB | HP IPF (Itanium Processor Family) SNMP MIB version 2 defining trap notifications for HP Integrity server system events. |
| HPIPFTRAP-MIB | HP IPF (Itanium Processor Family) SNMP MIB defining trap notifications for hardware and software events on HP Integrity servers. |
| HPN-ICF-CATV-TRANSCEIVER-MIB | SNMP MIB from HP Networking's ICF line for diagnosing CATV optical transceivers and monitoring signal levels on HP cable networking equipment. |
| HPN-ICF-CFCARD-MIB | HP Networking ICF SNMP MIB for CompactFlash card management including storage capacity and file system status on HP devices. |
| HPN-ICF-ENTITY-EXT-MIB | Extends the standard ENTITY-MIB with HP/Comware-specific physical entity attributes such as CPU and memory utilization. |
| HPN-ICF-ENTITY-VENDORTYPE-OID-MIB | Defines vendor-specific OID values for physical entity types used in HP/Comware device inventory MIBs. |
| HPN-ICF-ENTRELATION-MIB | Describes relationships between physical and logical entities in HP/Comware chassis-based systems. |
| HPN-ICF-FLASH-MAN-MIB | Manages flash memory partitions, files, and operations such as read/write/erase on HP/Comware networking devices. |
| HPN-ICF-RS485-MIB | Manages RS-485 serial interface configuration for console and out-of-band management on HP/Comware devices. |
| HPN-ICF-TRANSCEIVER-INFO-MIB | Monitors optical transceiver (SFP/XFP) Tx/Rx power, temperature, and vendor information on HP/Comware switches. |
| HPN-ICF-UPS-MIB | Monitors uninterruptible power supply (UPS) status, battery level, and alarm events on HP/Comware chassis. |
| HUAWEI-DAD-MIB | Huawei DAD (Dual Active Detection) MIB providing objects to configure and monitor dual-active detection in stacked or clustered Huawei switch systems. |
| HUAWEI-DEHA-MIB | Huawei DEHA (Device Enhanced High Availability) MIB for managing enhanced high availability features including non-stop routing and stateful failover. |
| HUAWEI-ENTITY-EXTENT-MIB IPNM ✓ | Extends the standard Entity MIB for Huawei devices, providing CPU utilization, memory usage, entity operational/admin status, optical module parameters, and hardware production information. |
| HUAWEI-ENVIRONMENT-MIB | Huawei environment monitoring MIB for tracking temperature, humidity, fan status, and power supply health on Huawei chassis-based equipment. |
| HUAWEI-ESAP-HOT-STANDBY-MIB | Huawei ESAP hot standby MIB for managing hot-standby redundancy for embedded service application processor modules. |
| HUAWEI-FRC-MA5100-MIB | Huawei MIB providing management objects specific to the MA5100 multi-service access platform in the FRC MA5100 series. |
| HUAWEI-HSL-MIB | Huawei HSL (High Speed Link) MIB providing management objects for high-speed inter-board and inter-chassis links on modular Huawei platforms. |
| HUAWEI-INNER-LINK-MIB | Huawei inner link MIB providing management objects for internal high-speed links between line cards and switch fabric within Huawei chassis. |
| HUAWEI-MEMORY-MIB | Huawei memory MIB providing memory utilization, pool allocation statistics, and threshold alerts for device memory resources. |
| HUAWEI-MODULE-INFO-MIB | Huawei module information MIB for reporting installed hardware module details, versions, and operational status. |
| HUAWEI-PERFORMANCE-MIB | Huawei performance MIB providing CPU, memory, and interface utilization counters for device-level performance monitoring. |
| HUAWEI-POWER-MIB | Huawei power supply MIB for monitoring power module status, input voltage, output load, and power redundancy state. |
| HUAWEI-REDUNDANCY-POWER-MIB | Huawei redundancy power MIB for monitoring dual power supply modules, failover events, and redundant power system state. |
| HUAWEI-RM-EXT-MIB | Huawei resource management extensions MIB for managing system resource allocation, process CPU usage, and memory partitioning. |
| HUAWEI-STORAGE-HARDWARE-MIB | Huawei storage hardware MIB for monitoring disk enclosures, controllers, disk drives, and hardware health on Huawei OceanStor. |
| HUAWEI-UNIVERSAL-POWER-MIB | Huawei universal power MIB for monitoring AC/DC power supply input, load distribution, and fan cooling in modular chassis. |
| HWG-PWR-MIB | HW group MIB for monitoring power-related environmental sensors including voltage, current, and power consumption measurements. |
| HWG-STE-MIB | HW group MIB for the STE (Sensor to Ethernet) device providing temperature and humidity monitoring via SNMP. |
| HWg-WLD-MIB | HW group MIB for the Water Leak Detector (WLD) device providing sensor status and alarm notifications for water detection. |
| IANA-ENTITY-MIB IPNM ✓ | Defines the IANAPhysicalClass textual convention that provides an indication of the general hardware type of a particular physical entity. |
| IBM-SYSTEM-HEALTH-MIB | IBM MIB for monitoring overall system health status including component fault states and environmental conditions on IBM servers. |
| IBM-SYSTEM-LMSENSOR-MIB | IBM MIB for hardware sensor monitoring providing temperature, voltage, and fan speed readings on IBM server hardware. |
| IBM-SYSTEM-POWER-MIB | IBM MIB for monitoring power supply status, voltage rails, and power consumption on IBM server hardware. |
| ICT-DIGITAL-SERIES-MIB | ICT (International Computer Technology) MIB for digital series power equipment providing output voltage, current, and alarm status. |
| ICT-DISTRIBUTION-PANEL-MIB | ICT MIB for power distribution panel management providing circuit breaker status, load measurements, and alarm notifications. |
| ICT-MIB | ICT root MIB defining the OID tree and common objects for ICT power and environmental monitoring equipment. |
| ICT-MODULAR-POWER-SYSTEM-MIB | ICT MIB for modular power system management providing rectifier, battery, and load status for telecommunications power plants. |
| ICT-SINE-WAVE-INVERTER-MIB | ICT MIB for sine-wave inverter management providing AC output parameters, battery status, and fault notifications. |
| IJ8060-MIB | MIB for the IJ8060 device providing hardware status and management objects for this network equipment. |
| INFORMANT-MBM | Informant Systems MIB for Motherboard Monitor (MBM) hardware sensor readings including temperature, voltage, and fan speed via SNMP. |
| INTEL-COMMON-BMC-MIB | Intel common baseboard management controller (BMC) MIB providing SNMP objects for server hardware health via IPMI. |
| INTEL-DIAG-MIB | Intel diagnostics MIB providing SNMP objects for initiating and reporting hardware self-test and diagnostic results on Intel devices. |
| INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB | Intel Multi-Flex Server fan MIB providing SNMP objects for cooling fan speed monitoring and fault detection in blade chassis. |
| INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB | Intel Multi-Flex Server power MIB providing SNMP objects for power supply unit status and power consumption monitoring in blade chassis. |
| INTELCORPORATIONSERVERHEALTH-MIB | Intel Corporation server health MIB providing SNMP objects for aggregated hardware health status across Intel server platforms. |
| Inverter-MIB | Argus Technologies inverter/UPS MIB providing SNMP objects for DC power plant and battery inverter status monitoring. |
| IOMMIB | I/O module MIB providing SNMP objects for managing I/O module cards including port status and traffic counters. |
| IPS-AUTH-MIB IPNM ✓ | Defines managed objects for managing user identity authorization in IP storage environments. |
| ISKRATEL-IPMI-MIB | Iskratel IPMI MIB providing SNMP objects for server and chassis hardware health monitoring via Intelligent Platform Management Interface. |
| IT-WATCHDOGS-V4-MIB | IT Watchdogs version 4 environmental monitoring MIB providing SNMP objects for temperature, humidity, and power sensor readings. |
| JUNIPER-CHASSIS-FWDD-MIB | Defines managed objects for Forwarding Daemon (fwdd) chassis components on Juniper Networks devices, monitoring forwarding plane health. |
| Juniper-Entity-CONF | Provides conformance statements for entity (hardware component) management on Juniper Networks E-series platforms. |
| JUNIPER-FABRIC-CHASSIS | Defines managed objects for fabric chassis monitoring in Juniper Networks QFabric and multi-chassis systems. |
| JUNIPER-FRU-MIB | Defines managed objects for Field Replaceable Unit (FRU) monitoring on Juniper Networks devices, including status, type, and operational state. |
| JUNIPER-MIB IPNM ✓ | Juniper Networks enterprise MIB providing hardware chassis information, system inventory, and device identification for Junos OS-based routers and switches. |
| JUNIPER-PFE-MIB | Juniper Networks MIB for monitoring Packet Forwarding Engine (PFE) statistics, errors, and utilization on Juniper routing platforms. |
| JUNIPER-POWER-SUPPLY-UNIT-MIB | Juniper Networks MIB for monitoring power supply unit (PSU) status, redundancy, and fault conditions on Juniper chassis. |
| JUNIPER-V1-TRAPS-CHAS | Juniper Networks MIB providing SNMPv1 chassis alarm trap translations for Juniper router hardware fault notifications. |
| KELVIN-pCOWeb-Chiller-MIB | KELVIN/Rittal MIB for monitoring chiller and HVAC unit parameters via pCOWeb SNMP interface for data center cooling. |
| KENTIX-ROOT-MIB | Kentix GmbH root MIB defining OID namespace for Kentix environmental and physical security monitoring sensor products. |
| KENYA-COMPONENT-MIB | MIB for managing hardware component inventory and status for equipment produced by a network device manufacturer using the KENYA platform. |
| KENYA-COMPONENT-TRAPS | MIB defining SNMP trap notifications for hardware component failures and state changes in KENYA platform network devices. |
| LENOVO-ENV-MIB | Lenovo MIB for monitoring environmental sensors including temperature, fan, and voltage on Lenovo server hardware. |
| LHX-MIB | Raritan MIB for managing Raritan LHX/SHX server rack heat exchanger and cooling unit status and temperature control. |
| LIEBERT-GP-AGENT-MIB | Liebert Corporation MIB for monitoring the Liebert Global Products (GP) SNMP agent status and communication on UPS and power systems. |
| LIEBERT-GP-CONDITIONS-MIB | Liebert Corporation MIB defining alarm conditions and event status monitoring for Liebert power and cooling infrastructure. |
| LIEBERT-GP-CONTROLLER-MIB | Liebert Corporation MIB for managing Liebert data center infrastructure controller parameters and operational settings. |
| LM-SENSORS-MIB IPNM ✓ | Exposes Linux lm_sensors hardware monitoring data via SNMP, providing temperature, fan speed, and voltage readings from motherboard and CPU sensors. |
| PARALLEL-MIB IPNM ✓ | Defines managed objects for parallel printer-like hardware ports. |
| RBN-CARDMON-CAP | Declares AGENT-CAPABILITIES for line card monitoring on Ericsson SmartEdge platforms. |
| RBN-CARDMON-MIB | Monitors line and service card operational state, resets, and hardware faults on SmartEdge. |
| RS-232-MIB IPNM ✓ | Defines managed objects for RS-232-like hardware character port interfaces, including asynchronous and synchronous serial ports. |
| UPS-MIB IPNM ✓ | Defines managed objects for managing Uninterruptible Power Supply (UPS) systems, including battery status, input/output power measurements, alarms, and test controls. |
| VMWARE-ENV-MIB | Defines variables and trap types for reporting the state of physical hardware components on ESXi hosts, using CIM indications or IPMI sensors for environmental monitoring. |
| VMWARE-RESOURCES-MIB | Provides instrumentation for ESXi hypervisor resource usage including CPU, memory, and disk utilization. |