All MIBs › ALPHA-RESOURCE-MIB
Organization: Alpha Technologies Ltd.
Last Updated: 2015-07-28
Category: Hardware and Environment, Textual Conventions and Registries
Description:
Alpha Technologies resource MIB providing common textual conventions and base objects for Alpha power system MIBs.
Imported Objects
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| OBJECT-TYPE | |
| Unsigned32 | |
| enterprises |
From SNMPv2-TC
| TEXTUAL-CONVENTION |
What Is ALPHA-RESOURCE-MIB?
ALPHA-RESOURCE-MIB is Alpha Technologies' enterprise MIB defining common textual conventions and shared base objects used across Alpha's power system management MIB modules, for products such as DC power plants, inverters, and UPS/standby power systems used in telecom and cable environments. Rather than exposing specific runtime metrics itself, it provides the reusable data types and resource information blocks that other Alpha power-system MIBs build upon to describe controller and power resource status. Given Alpha's product focus, the underlying purpose supported by this MIB is monitoring of power system hardware health, such as battery status, rectifier/inverter state, and system controller conditions, even though the concrete objects live in companion Alpha MIBs that import these conventions. The ALPHA-RESOURCE-MIB MIB file itself defines no pollable objects, serving only as the shared type library that other Alpha power-system MIBs import. Nearly all other Alpha Technologies product MIBs depend on this resource/TC module for consistent typing of status and alarm values. It is deployed in telecom central offices, cable headends, and other facilities using Alpha Technologies DC power and backup power system controllers.
IPNetwork Monitor allows you to monitor SNMP objects defined in ALPHA-RESOURCE-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Alpha Technologies Cordex CXC HP — current digital power system controller, backward compatible with Cordex rectifiers/inverters
- Alpha Technologies CXPS-E3 — current modular DC power system
Monitoring Examples
No sample objects were provided for this module, consistent with its role as a shared textual-conventions/base-resource definition file rather than a data-object MIB. In practice, administrators would not poll ALPHA-RESOURCE-MIB directly but would see its defined types used as the syntax for status and alarm objects in other Alpha Technologies power-system MIBs, for example an enumerated controller-status type applied to a specific power plant's monitoring table. As a foundational conventions module, it has no standalone monitoring scenario.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| alpha | 1.3.6.1.4.1.7309 | This MIB defines the information block(s) available in system controllers. | ||
| controller | 1.3.6.1.4.1.7309.5 | |||
| controllerInfo | 1.3.6.1.4.1.7309.5.1 | |||
| OCT controllerInfoName | 1.3.6.1.4.1.7309.5.1.1 | OCTET STRING | read-only | User configurable text name of the Controller. |
| OCT controllerInfoDescription | 1.3.6.1.4.1.7309.5.1.2 | OCTET STRING | read-only | User configurable description of the Controller. |
| OCT controllerInfoSoftwareVersion | 1.3.6.1.4.1.7309.5.1.3 | OCTET STRING | read-only | Software version of the Controller application. |
| OCT controllerInfoOperatingSystemVersion | 1.3.6.1.4.1.7309.5.1.4 | OCTET STRING | read-only | Operating system version number. |
| OCT controllerInfoHardwareVersion | 1.3.6.1.4.1.7309.5.1.5 | OCTET STRING | read-only | Hardware version number. |
| controllerExtInfoTable | 1.3.6.1.4.1.7309.5.1.100 | not-accessible | Controller specific information table. | |
| controllerExtInfoEntry | 1.3.6.1.4.1.7309.5.1.100.1 | not-accessible | Entries appear in this table for each possible alarm state. This table MUST be persistent across system reboots. | |
| U32 controllerExtInfoIndex | 1.3.6.1.4.1.7309.5.1.100.1.1 | Unsigned32 | not-accessible | Incremental integer value for each instance of the . |
| OCT controllerExtInfoName | 1.3.6.1.4.1.7309.5.1.100.1.2 | OCTET STRING | read-only | Name of the data value presented in the instance of the entry. |
| OCT controllerExtInfoStringValue | 1.3.6.1.4.1.7309.5.1.100.1.3 | OCTET STRING | read-only | String value of the data field presented by the controller info entry. |
| OCT controllerExtInfoUnit | 1.3.6.1.4.1.7309.5.1.100.1.4 | OCTET STRING | read-only | Unit name of the numeric value of the controller info entry. |
| SCA controllerExtInfoNumberValue | 1.3.6.1.4.1.7309.5.1.100.1.5 | ScaledNumber | read-only | Number value of the data field presented by the controller info entry. |
| resource | 1.3.6.1.4.1.7309.5.2 | |||
| componentList | 1.3.6.1.4.1.7309.5.2.1 | |||
| I32 componentListCount | 1.3.6.1.4.1.7309.5.2.1.1 | Integer32 | read-only | The number of available objects in componentList. |
| componentListTable | 1.3.6.1.4.1.7309.5.2.1.2 | not-accessible | Object componentList describes the following: Systems ( DC System, AC System, Converter System, etc. ) Devices ( ADIO, Rectifier, Converter, Inverter, etc. ) | |
| componentListEntry | 1.3.6.1.4.1.7309.5.2.1.2.1 | not-accessible | Entry to the component list describing the available systems and devices within the Cordex controller. Indexing: 1. Component type - please refer to componentListType 2. Snmp ID - please refer to componentListReference Configurable ID allow for component monitoring on a specific index if the method of monitoring is locked on the index value. | |
| U32 componentListReference | 1.3.6.1.4.1.7309.5.2.1.2.1.1 | Unsigned32 | not-accessible | Indentification number assigned to the component. |
| OCT componentListStaticName | 1.3.6.1.4.1.7309.5.2.1.2.1.2 | OCTET STRING | read-only | Non-configurable name permanently assigned to the component. Filtering on this data value is possible and recommended due to its static nature. |
| OCT componentListConfiguredName | 1.3.6.1.4.1.7309.5.2.1.2.1.3 | OCTET STRING | read-write | User configurable name of the component. Filtering on this data value is not recommended. |
| U32 componentListType | 1.3.6.1.4.1.7309.5.2.1.2.1.4 | Unsigned32 | not-accessible | The type of the component based on power system terminology. 1 - Controller 2 - DC System 3 - ADIO 4 - Rectifier 5 - Converter 6 - Inverter 7 - BCMC 8 - T2S 9 - AC Input Bus 10 - Battery String 11 - Disconnect 12 - Load 13 - Shunt 14 - SNMP Destinations 15 - CAN Bus |
| OCT componentListModelNumber | 1.3.6.1.4.1.7309.5.2.1.2.1.5 | OCTET STRING | read-only | Component model number where applicable. This is available on component entries which describes hardware modules. |
| OCT componentListSerialNumber | 1.3.6.1.4.1.7309.5.2.1.2.1.6 | OCTET STRING | read-only | Serial number of the device only if the component is of physical device type. |
| OID componentListSystemPointer | 1.3.6.1.4.1.7309.5.2.1.2.1.7 | OBJECT IDENTIFIER | read-only | Table entry reference to the component table of the system component that the described item belongs to. Example: A rectifier component will have a reference to the Rectifier System that it belongs to. |
| dataList | 1.3.6.1.4.1.7309.5.2.2 | |||
| I32 dataListCount | 1.3.6.1.4.1.7309.5.2.2.1 | Integer32 | read-only | The number of defined data fields available for query. |
| dataListTable | 1.3.6.1.4.1.7309.5.2.2.2 | not-accessible | Table of data fields available for query. | |
| dataListEntry | 1.3.6.1.4.1.7309.5.2.2.2.1 | not-accessible | Data field entry of available fields. Indexes: 1. componentListType - indicates which component can provide the field of interest. 2. dataListReference - the ID permanently assigned to the field. | |
| U32 dataListReference | 1.3.6.1.4.1.7309.5.2.2.2.1.1 | Unsigned32 | not-accessible | Non-configurable ID permanently assigned to the field entry. |
| OCT dataListName | 1.3.6.1.4.1.7309.5.2.2.2.1.2 | OCTET STRING | read-write | Non-configurable string name of the field represented in the entry. |
| U32 dataListType | 1.3.6.1.4.1.7309.5.2.2.2.1.3 | Unsigned32 | not-accessible | Canonical data type of the field entry. 0 - None 1 - Numeric 2 - Boolean 3 - Time 4 - String 5 - Choice / Selected options |
| OCT dataListUnit | 1.3.6.1.4.1.7309.5.2.2.2.1.4 | OCTET STRING | read-write | Unit type of the value represented by the entry. |
| data | 1.3.6.1.4.1.7309.5.2.3 | |||
| I32 dataCount | 1.3.6.1.4.1.7309.5.2.3.1 | Integer32 | read-only | The number of defined data points available for query. |
| dataTable | 1.3.6.1.4.1.7309.5.2.3.2 | not-accessible | Table of data values associated to live data availabe from the Cordex HP controller. | |
| dataEntry | 1.3.6.1.4.1.7309.5.2.3.2.1 | not-accessible | Conceptual row of data value for the referencing data field type and component that it belongs to. | |
| U32 dataReference | 1.3.6.1.4.1.7309.5.2.3.2.1.1 | Unsigned32 | not-accessible | Non-configurable ID permanently assigned to the field entry. |
| SCA dataNumberValue | 1.3.6.1.4.1.7309.5.2.3.2.1.2 | ScaledNumber | read-only | Numeric value of the data field. |
| OCT dataStringValue | 1.3.6.1.4.1.7309.5.2.3.2.1.3 | OCTET STRING | read-only | String value of the data field. |
| configurationList | 1.3.6.1.4.1.7309.5.2.4 | |||
| I32 configurationListCount | 1.3.6.1.4.1.7309.5.2.4.1 | Integer32 | read-only | The number of defined configuration fields available for query. |
| configurationListTable | 1.3.6.1.4.1.7309.5.2.4.2 | not-accessible | Table of configuration entries. | |
| configurationListEntry | 1.3.6.1.4.1.7309.5.2.4.2.1 | not-accessible | Configuration field entries available for GET and SET. | |
| U32 configurationListReference | 1.3.6.1.4.1.7309.5.2.4.2.1.1 | Unsigned32 | not-accessible | A numerical ID value permanently assigned to the configuration field. |
| OCT configurationListName | 1.3.6.1.4.1.7309.5.2.4.2.1.2 | OCTET STRING | read-only | A non-configurable string name of the configuration field. |
| I32 configurationListType | 1.3.6.1.4.1.7309.5.2.4.2.1.3 | Integer32 | read-only | Conanical data type of the configuration field. 0 - Unknown 1 - Numeric 2 - Boolean 3 - Time 4 - String 5 - Choice / Selected Options |
| OCT configurationListUnit | 1.3.6.1.4.1.7309.5.2.4.2.1.4 | OCTET STRING | read-only | Unit of the numeric value of the configuration field. |
| configuration | 1.3.6.1.4.1.7309.5.2.5 | |||
| I32 configurationCount | 1.3.6.1.4.1.7309.5.2.5.1 | Integer32 | read-only | The number of defined configuration points available for query. |
| configurationTable | 1.3.6.1.4.1.7309.5.2.5.2 | not-accessible | Table of configuration entries. | |
| configurationEntry | 1.3.6.1.4.1.7309.5.2.5.2.1 | not-accessible | Configuration field entry. | |
| U32 configurationReference | 1.3.6.1.4.1.7309.5.2.5.2.1.1 | Unsigned32 | not-accessible | Non-configurable ID permanently assigned to the field entry. |
| SCA configurationNumberValue | 1.3.6.1.4.1.7309.5.2.5.2.1.2 | ScaledNumber | read-write | Numbered value of the configuration referenced by the Configuration Type and the Component Reference. |
| OCT configurationStringValue | 1.3.6.1.4.1.7309.5.2.5.2.1.3 | OCTET STRING | read-write | String value of the configuration referenced by the Configuration Type and the Component Reference. |
| commandList | 1.3.6.1.4.1.7309.5.2.6 | |||
| I32 commandListCount | 1.3.6.1.4.1.7309.5.2.6.1 | Integer32 | read-only | The number of defined data points available for query. |
| commandListTable | 1.3.6.1.4.1.7309.5.2.6.2 | not-accessible | Table of commands available from the Cordex HP Controller. | |
| commandListEntry | 1.3.6.1.4.1.7309.5.2.6.2.1 | not-accessible | Conceptual row of a command item in the Command List Table. | |
| U32 commandListReference | 1.3.6.1.4.1.7309.5.2.6.2.1.1 | Unsigned32 | not-accessible | Reference value to identify available commands published by the Cordex HP Controller. |
| OCT commandListName | 1.3.6.1.4.1.7309.5.2.6.2.1.2 | OCTET STRING | read-write | Name of the command. |
| command | 1.3.6.1.4.1.7309.5.2.7 | |||
| I32 commandCount | 1.3.6.1.4.1.7309.5.2.7.1 | Integer32 | read-only | The number of defined command points available for query. |
| commandTable | 1.3.6.1.4.1.7309.5.2.7.2 | not-accessible | Table of command fields that are available in the Cordex HP Controller. | |
| commandEntry | 1.3.6.1.4.1.7309.5.2.7.2.1 | not-accessible | Conceptual row of the Command Table. | |
| U32 commandReference | 1.3.6.1.4.1.7309.5.2.7.2.1.1 | Unsigned32 | not-accessible | Non-configurable ID permanently assigned to the field entry. |
| I32 commandTrigger | 1.3.6.1.4.1.7309.5.2.7.2.1.2 | Integer32 | read-write | Command field that is the trigger to send command referenced by the Command Type and the Component that it belongs to. |
| alarmType | 1.3.6.1.4.1.7309.5.2.8 | |||
| I32 alarmTypeCount | 1.3.6.1.4.1.7309.5.2.8.1 | Integer32 | read-only | The number of defined alarm points available for query. |
| alarmTypeTable | 1.3.6.1.4.1.7309.5.2.8.2 | not-accessible | Table of alarms available from the Cordex HP Controller. | |
| alarmTypeEntry | 1.3.6.1.4.1.7309.5.2.8.2.1 | not-accessible | Conceptual row of a alarm item in the Alarm List Table. | |
| U32 alarmTypeReference | 1.3.6.1.4.1.7309.5.2.8.2.1.1 | Unsigned32 | not-accessible | Reference value to identify available alarms published by the Cordex HP Controller. |
| OCT alarmTypeName | 1.3.6.1.4.1.7309.5.2.8.2.1.2 | OCTET STRING | read-only | Name of the alarm. |
| alarm | 1.3.6.1.4.1.7309.5.2.9 | |||
| I32 alarmCount | 1.3.6.1.4.1.7309.5.2.9.1 | Integer32 | read-only | The number of defined alarm points available for query. |
| alarmTable | 1.3.6.1.4.1.7309.5.2.9.2 | not-accessible | Table of alarm fields that are available in the Cordex HP Controller. | |
| alarmEntry | 1.3.6.1.4.1.7309.5.2.9.2.1 | not-accessible | Conceptual row of the Alarm Table. | |
| U32 alarmState | 1.3.6.1.4.1.7309.5.2.9.2.1.1 | Unsigned32 | read-only | Interger representation of the state of the alarm and its priority level. 0 - Normal 1 - Warning 2 - Minor 3 - Major 4 - Critical |
| resourceConformance | 1.3.6.1.4.1.7309.5.2.100 | |||
| resourceCompliances | 1.3.6.1.4.1.7309.5.2.100.1 | |||
| resourceCompliance | 1.3.6.1.4.1.7309.5.2.100.1.1 | The compliance statement for systems supporting the Alpha Resource MIB. | ||
| resourceGroups | 1.3.6.1.4.1.7309.5.2.100.1.2 | |||
| alphaControllerGroup | 1.3.6.1.4.1.7309.5.2.100.1.2.1 | Alpha controller data list group. | ||
| alphaComponentGroup | 1.3.6.1.4.1.7309.5.2.100.1.2.2 | Component data list group. | ||
| alphaDataTypeGroup | 1.3.6.1.4.1.7309.5.2.100.1.2.3 | Data type list group. | ||
| alphaDataGroup | 1.3.6.1.4.1.7309.5.2.100.1.2.4 | Data type list group. | ||
| alphaConfigurationTypeGroup | 1.3.6.1.4.1.7309.5.2.100.1.2.5 | Data type list group. | ||
| alphaConfigurationGroup | 1.3.6.1.4.1.7309.5.2.100.1.2.6 | Data type list group. | ||
| alphaCommandTypeGroup | 1.3.6.1.4.1.7309.5.2.100.1.2.7 | Data type list group. | ||
| alphaCommandGroup | 1.3.6.1.4.1.7309.5.2.100.1.2.8 | Data type list group. | ||
| simple | 1.3.6.1.4.1.7309.5.3 |
RFC description
Alpha vendor resource management MIB for system resource monitoring.
Start monitoring Alpha Technologies Cordex CXC HP / CXPS-E3 power system controllers with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.