| OID symbolic | OID numeric | Type | Access | Description |
| ciscoEntityPfeMib | 1.3.6.1.4.1.9.9.265 | | | The Packet Forwarding Engine technology are Cisco developed
Network Processors, which accelerates certain features in
order to provide better network performance.
An agent uses this MIB to monitor the performance history
on any active PFE pipeline listed in the ENTITY-MIB (RFC 2737)
entPhysicalTable. This monitoring is via measurement periods
of actual, 1-minute, 5-minutes and 15-minutes.
For the 1-minute and 5-minute measurement periods, perfor-
mance statistics are calculated and displayed based on pre-
vious 1 minute and 5 minute respectively.
For the 15-minute period, the performance statistics are
accumulated in fifteen minute intervals. At any one time,
an agent maintains one current (incomplete) interval and up
to 96 completed intervals (24 hours worth). Fewer than 96
intervals of data will be available if the agent has been
restarted within the last 24 hours. In addition, there is a
rolling 24-hour total of each performance statistic.
There is no requirement for an agent to ensure fixed rela-
tionship between the start of a fifteen minute interval and
any wall clock; however some agents may align the fifteen
minute intervals with quarter hours. |
| cePfeMIBNotifications | 1.3.6.1.4.1.9.9.265.0 | | | |
| NTF cePfeHistThldEvent | 1.3.6.1.4.1.9.9.265.0.1 | | | This notification is generated when a threshold event has
occurred and the cePfeHistNotifiesEnable is set to
'notify (3)' or 'logAndNotify(4)'.
After generating this notification, another such notifica-
tion will not be sent out until the sample value has fallen
below the threshold value. |
| NTF cePfeHistRestartEvent | 1.3.6.1.4.1.9.9.265.0.2 | | | This notification is generated when a restart event has
occurred and the cePfeHistNotifiesEnable is set to
'notifyp (3)' or 'logAndNotify(4)'. |
| cePfeMIBObjects | 1.3.6.1.4.1.9.9.265.1 | | | |
| cePfePerformance | 1.3.6.1.4.1.9.9.265.1.1 | | | |
| cePfePerfConfigTable | 1.3.6.1.4.1.9.9.265.1.1.1 | | not-accessible | This table contains configuration information on a PFE
pipeline. |
| cePfePerfConfigEntry | 1.3.6.1.4.1.9.9.265.1.1.1.1 | | not-accessible | An entry will exist for each entry in the entPhysicalTable
that correspond to an active PFE pipeline. |
| U32 cePfePerfConfigTimeElapsed | 1.3.6.1.4.1.9.9.265.1.1.1.1.1 | Unsigned32 | read-only | The number of seconds that have elapsed since the beginning
of the current 15 min interval. If for some reason, such as
an adjustment in the system's time-of-day clock, the current
interval exceeds the maximum value, the agent will return the
maximum value. |
| U32 cePfePerfConfigValidIntervals | 1.3.6.1.4.1.9.9.265.1.1.1.1.2 | Unsigned32 | read-only | The number of completed 15 min intervals for which valid
PFE performance data has been collected. The value
will be 96 unless the interface was brought online within the
last 24 hours, in which case the value will be the number of
completed 15 minute intervals since the PFE pipeline has
been online. |
| PER cePfePerfConfigThldUtilization | 1.3.6.1.4.1.9.9.265.1.1.1.1.3 | Percentage | read-write | This object contains the threshold value for the
cePfePerfCurrentUtilization object. If during the last 5
second measurement period the cePfePerfCurrentUtilization
object becomes greater than or equal to this threshold value,
an event of type 'thldUtilizationEvent' will be genera-
ted.
Value of zero indicates that no comparison is being made
between the cePfePerfCurrentUtilization object value and
the threshold value, therefore no event action will be gene-
rated. |
| PER cePfePerfConfigThldEfficiency | 1.3.6.1.4.1.9.9.265.1.1.1.1.4 | Percentage | read-write | This object contains the threshold value for the
cePfePerfCurrentEffciency object. If during the last 5
second measurement period the cePfePerfCurrentEfficiency
object becomes less than or equal to this threshold value,
an event of type 'thldEfficiencyEvent' will be genera-
ted.
Value of zero indicates that no comparison is being made
between the cePfePerfCurrentEfficiency object value and
the threshold value, therefore no event action will be gene-
rated. |
| PER cePfePerfConfigThld1MinUtilization | 1.3.6.1.4.1.9.9.265.1.1.1.1.5 | Percentage | read-write | This object contains the threshold value for the
cePfePerfCurrent1MinUtilization object. If during the last 1
minute measurement period the cePfePerfCurrent1MinUtilization
object becomes greater than or equal to this threshold value,
an event of type 'thld1MinUtilizationEvent' will be genera-
ted.
Value of zero indicates that no comparison is being made
between the cePfePerfCurrent1MinUtilization object value and
the threshold value, therefore no event action will be gene-
rated. |
| PER cePfePerfConfigThld1MinEfficiency | 1.3.6.1.4.1.9.9.265.1.1.1.1.6 | Percentage | read-write | This object contains the threshold value for the
cePfePerfCurrent1MinEfficiency object. If during the last 1
minute measurement period the cePfePerfCurrent1MinEfficiency
object becomes less than or equal to this threshold value,
an event of type 'thld1MinEfficiencyEvent' will be genera-
ted.
Value of zero indicates that no comparison is being made
between the cePfePerfCurrent1MinEfficiency object value and
the threshold value, therefore no event action will be gene-
rated. |
| PER cePfePerfConfigThld5MinUtilization | 1.3.6.1.4.1.9.9.265.1.1.1.1.7 | Percentage | read-write | This object contains the threshold value for the
cePfePerfCurrent5MinUtilization object. If during the last 5
minute measurement period the cePfePerfCurrent5MinUtilization
object becomes greater than or equal to this threshold value,
an event of type 'thld5MinUtilizationEvent' will be genera-
ted.
Value of zero indicates that no comparison is being made
between the cePfePerfCurrent5MinUtilization object value and
the threshold value, therefore no event action will be gene-
rated. |
| PER cePfePerfConfigThld5MinEfficiency | 1.3.6.1.4.1.9.9.265.1.1.1.1.8 | Percentage | read-write | This object contains the threshold value for the
cePfePerfCurrent5MinEfficiency object. If during the last 5
minute measurement period the cePfePerfCurrent5MinEfficiency
object becomes less than or equal to this threshold value,
an event of type 'thld5MinEfficiencyEvent' will be genera-
ted.
Value of zero indicates that no comparison is being made
between the cePfePerfCurrent5MinEfficiency object value and
the threshold value, therefore no event action will be gene-
rated. |
| cePfePerfCurrentTable | 1.3.6.1.4.1.9.9.265.1.1.2 | | not-accessible | This table maintains PFE current running performance, which
are collected at various measurement periods. |
| cePfePerfCurrentEntry | 1.3.6.1.4.1.9.9.265.1.1.2.1 | | not-accessible | An entry containing performance information applicable to
a particular PFE pipeline. |
| CUR cePfePerfCurrentUtilization | 1.3.6.1.4.1.9.9.265.1.1.2.1.1 | CurrentUtilization | read-only | This object provides the actual PFE percentage utilization.
It is determined by the number of new work contexts + feedback
contexts divided by total number of contexts that can be
supported by the PFE pipeline. |
| CUR cePfePerfCurrentEfficiency | 1.3.6.1.4.1.9.9.265.1.1.2.1.2 | CurrentEfficiency | read-only | This object provides the actual PFE percentage efficiency.
It is determined by the total number of contexts per second
divided by maximum theoretical contexts per second supported
by the PFE pipeline. Under normal conditions, this number will
be 100 and when efficiency starts degrading, it will start
going down until it reaches zero. |
| CUR cePfePerfCurrent1MinUtilization | 1.3.6.1.4.1.9.9.265.1.1.2.1.3 | CurrentUtilization | read-only | This object provides the PFE percentage utilization over the
previous 1 minute period. It is determined by the number of new
work contexts + feedback contexts divided by total number of
contexts that can be supported by the PFE pipeline. |
| CUR cePfePerfCurrent1MinEfficiency | 1.3.6.1.4.1.9.9.265.1.1.2.1.4 | CurrentEfficiency | read-only | This object provides the PFE percentage efficiency over the
previous 1 minute period. It is determined by the totalnumber
of contexts per second divided by maximum theoretical contexts
per second supported by the PFE pipeline. Under normal
conditions, this number will be 100 and when efficiency starts
degrading, it will start going down until it reaches zero. |
| CUR cePfePerfCurrent5MinUtilization | 1.3.6.1.4.1.9.9.265.1.1.2.1.5 | CurrentUtilization | read-only | This object provides the PFE percentage utilization over the
previous 5 minutes period. It is determined by the number of
new work contexts + feedback contexts divided by total number
of contexts that can be supported by the PFE pipeline. |
| CUR cePfePerfCurrent5MinEfficiency | 1.3.6.1.4.1.9.9.265.1.1.2.1.6 | CurrentEfficiency | read-only | This object provides the PFE percentage efficiency over the
previous 5 minutes period. It is determined by the total number
of contexts per second divided by maximum theoretical contexts
per second supported by the PFE pipeline. Under normal
conditions, this number will be 100 and when efficiency starts
degrading, it will start going down until it reaches zero. |
| cePfePerfIntervalTable | 1.3.6.1.4.1.9.9.265.1.1.3 | | not-accessible | This table contains performance statistics for completed
15 minutes intervals, specifically up to 96 such intervals
over a 24 hours of operation. |
| cePfePerfIntervalEntry | 1.3.6.1.4.1.9.9.265.1.1.3.1 | | not-accessible | An entry containing performance information applicable to
a particular PFE pipeline at a specific interval. |
| U32 cePfePerfIntervalNumber | 1.3.6.1.4.1.9.9.265.1.1.3.1.1 | Unsigned32 | not-accessible | An interval number between 1 and 96, where 1 is the most
recently completed 15 min interval and 96 is the 15 min
interval completed 23 hours and 45 minutes prior to interval
1. |
| NUM cePfePerfIntervalUtilization | 1.3.6.1.4.1.9.9.265.1.1.3.1.2 | IntervalUtilization | read-only | The percentage of processor utilization by the PFE pipeline
during this completed 15 min interval. |
| NUM cePfePerfIntervalEfficiency | 1.3.6.1.4.1.9.9.265.1.1.3.1.3 | IntervalEfficiency | read-only | The percentage of processor efficiency by the PFE pipeline
during this completed 15 min interval. Under normal conditions,
this number will be 100 and when efficiency starts degrading,
it will start going down until it reaches zero. |
| cePfePerfTotalTable | 1.3.6.1.4.1.9.9.265.1.1.4 | | not-accessible | This table contains the running utilization and efficiency
of the PFE pipeline for the 24 hour period preceding the
current interval. If the agent was restarted less than 24
hours ago, i.e., when there are less than 96 intervals in the
cePfePerfIntervalTable, it will contain the running utiliza-
tion and efficiency up to the last collected 15 minute inter-
val. |
| cePfePerfTotalEntry | 1.3.6.1.4.1.9.9.265.1.1.4.1 | | not-accessible | An entry containing performance information applicable to
a particular PFE pipeline at the end of each interval in the
cePfePerfIntervalTable. |
| TOT cePfePerfTotalUtilization | 1.3.6.1.4.1.9.9.265.1.1.4.1.1 | TotalUtilization | read-only | The running utilization by the PFE pipeline for the prece-
ding 24 hrs. |
| TOT cePfePerfTotalEfficiency | 1.3.6.1.4.1.9.9.265.1.1.4.1.2 | TotalEfficiency | read-only | The running efficiency by the PFE pipeline for the preceding
24 hrs. Under normal conditions, this number will be 100 and
when efficiency starts degrading, it will start going down
until it reaches zero. |
| cePfeHistory | 1.3.6.1.4.1.9.9.265.1.2 | | | |
| EVE cePfeHistNotifiesEnable | 1.3.6.1.4.1.9.9.265.1.2.1 | EventType | read-write | This object indicates what type of action should be taken by
the agent when a event is generated. |
| U32 cePfeHistTableSize | 1.3.6.1.4.1.9.9.265.1.2.2 | Unsigned32 | read-write | This object specifies the number of entries that the
cePfeHistTable can contain. When a event is generated, and
the capacity of the cePfeHistTable has reached the value
specified by this object, then the agent deletes the oldest
entity in order to accommodate the new entry. A value of '0'
prevents any history from being retained. |
| U32 cePfeHistTableLastIndex | 1.3.6.1.4.1.9.9.265.1.2.3 | Unsigned32 | read-only | This object specifies the value of the cePfeHistIndex object
corresponding to the last entry added to the table by the
agent. It will return zero if there are no entries in the
table.
If the management client uses the notifications defined by
this module, then it can poll this object to determine
whether it has missed a notification sent by the agent. |
| cePfeHistTable | 1.3.6.1.4.1.9.9.265.1.2.4 | | not-accessible | This table contains a history of events generated by the
agent. |
| cePfeHistEntry | 1.3.6.1.4.1.9.9.265.1.2.4.1 | | not-accessible | An entry will exist for each event that has occured while
cePfeHistNotifiesEnable object is set to 'log(2)' or
'logAndNotify(4)'. |
| U32 cePfeHistIndex | 1.3.6.1.4.1.9.9.265.1.2.4.1.1 | Unsigned32 | not-accessible | An integer value uniquely identifying the entry in the table.
The value of this object starts at '1' and monotonically
increases for each event condition transition monitored by the
agent. If the value of this object is '4294967295', the agent
will reset the index to '1' upon monitoring the next event
condition transition. |
| PHY cePfeHistEntPhysIndex | 1.3.6.1.4.1.9.9.265.1.2.4.1.2 | PhysicalIndex | read-only | The value in this object is equal to the value of the
entPhysicalIndex, from the Physical Entity Table (RFC 2037),
that is associated with the PFE pipeline that has caused
this event. |
| HIS cePfeHistType | 1.3.6.1.4.1.9.9.265.1.2.4.1.3 | HistEventType | read-only | This object describes the type of event that has occurred. |
| PER cePfeHistThld | 1.3.6.1.4.1.9.9.265.1.2.4.1.4 | Percentage | read-only | The configured value of the specific threshold. |
| PER cePfeHistValue | 1.3.6.1.4.1.9.9.265.1.2.4.1.5 | Percentage | read-only | The actual value of the specific performance objects, at the
time of the sample, which is related to the threshold event. |
| STR cePfeHistRestartReason | 1.3.6.1.4.1.9.9.265.1.2.4.1.6 | DisplayString | read-only | The reason for which the PFE pipeline has restarted. |
| TIM cePfeHistTimeStamp | 1.3.6.1.4.1.9.9.265.1.2.4.1.7 | TimeStamp | read-only | This object specifies the value of the sysUpTime object at
the time the event was generated. |
| cePfeMIBConformance | 1.3.6.1.4.1.9.9.265.2 | | | |
| cePfeMIBCompliances | 1.3.6.1.4.1.9.9.265.2.1 | | | |
| cePfeMIBPerformanceCompliance | 1.3.6.1.4.1.9.9.265.2.1.1 | | | An Entity-MIB implementation can implement this module to
provide PFE pipeline performance history. |
| cePfeMIBGroups | 1.3.6.1.4.1.9.9.265.2.2 | | | |
| cePfeMIBPerformanceGroup | 1.3.6.1.4.1.9.9.265.2.2.1 | | | The collection of objects which are used to manage the per-
formance history of the PFE pipeline. |
| cePfeMIBCurrentGroup | 1.3.6.1.4.1.9.9.265.2.2.2 | | | The collection of objects which are used to maintain the PFE
processor's performance history over a 24 hour of operation. |
| cePfeMIBIntervalGroup | 1.3.6.1.4.1.9.9.265.2.2.3 | | | The collection of objects which are used to maintain the PFE
processor's performance history over a 24 hour of operation. |
| cePfeMIBTotalGroup | 1.3.6.1.4.1.9.9.265.2.2.4 | | | The collection of objects which are used to manage the
threshold configuration for the PFE pipeline performance. |
| cePfeMIBHistGroup | 1.3.6.1.4.1.9.9.265.2.2.5 | | | The collection of objects which are used to manage the
threshold configuration for the PFE pipeline performance. |
| cePfeMIBHistEventGroup | 1.3.6.1.4.1.9.9.265.2.2.6 | | | The collection of objects which are used to generate a
threshold event for the PFE pipeline performance. |