All MIBs › CPS6000-MIB
Organization: Lineage Power
Last Updated: 2009-06-18
Category: Hardware and Environment
Description: Manages CyberPower 6000-series UPS units providing power quality metrics, battery health, and alarm notifications.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CPS6000-MIB?
CPS6000-MIB is a CyberPower Systems MIB for the CPS6000-series UPS/power protection product line, sitting under CyberPower's private enterprise "controllermibs" branch. It exposes DC power-subsystem objects for one or more DC/battery circuits (cps6000Dc1Ide, cps6000Dc1Des, cps6000Dc1Typ, cps6000Dc1Stt, cps6000Dc1Vdc, cps6000Dc1Adc, cps6000Dc1Cap, cps6000Dc1Olcap, cps6000Dc1Scap, cps6000Dc1Bty), covering identifiers, descriptions, hardware type, operational status, DC voltage/current, and capacity metrics. Its principal monitoring use is hardware health of the UPS's power system - battery status, DC voltage/current, and available/online/spare capacity - which together reveal battery aging, load conditions, and impending power problems before an outage causes a shutdown. As a self-contained vendor MIB it does not explicitly reference other IETF MIBs, though it parallels the general intent of the standard UPS-MIB. It is deployed wherever CyberPower CPS6000-series UPS units protect data-center or server-room equipment and are monitored over SNMP. Engineers can download the CPS6000-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in CPS6000-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- CyberPower CPS6000-series UPS
Monitoring Examples
An admin would poll cps6000Dc1Stt (DC circuit status) together with cps6000Dc1Vdc and cps6000Dc1Adc (DC voltage/current) to confirm a battery string is online and delivering expected power under load. A drop in cps6000Dc1Cap or cps6000Dc1Scap (capacity/spare capacity) alongside a degraded cps6000Dc1Stt would indicate an aging or failing battery needing replacement before it can no longer ride through a utility outage. cps6000Dc1Ide and cps6000Dc1Des provide the identifying label and description for the specific DC circuit being reported.
What Can Be Monitored
- DC circuit status
- DC voltage
- DC current
- battery capacity
- online/spare capacity
- battery health
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| enterprises |
From SNMPv2-TC
| DisplayString |
How to Use in IPNetwork Monitor
Example using cps6000Dc1Vdc OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| controllermibs | 1.3.6.1.4.1.10520.2 | |||
| cps6000 | 1.3.6.1.4.1.10520.2.1.1 | MIB for CPS6000 Power System. | ||
| cps6000AlarmEntry | 1.3.6.1.4.1.10520.2.1.1.32.1 | not-accessible | Entry of information for one Alarm | |
| STR cps6000AlarmEntryAcc | 1.3.6.1.4.1.10520.2.1.1.32.1.5 | DisplayString | read-write | Contact Closure Values: R1, R2, R3, R4 |
| INT cps6000AlarmEntryAst | 1.3.6.1.4.1.10520.2.1.1.32.1.3 | INTEGER | read-only | State Values: inactive(0), active(1) |
| STR cps6000AlarmEntryBth | 1.3.6.1.4.1.10520.2.1.1.32.1.8 | DisplayString | read-write | Boost Threshold |
| STR cps6000AlarmEntryDes | 1.3.6.1.4.1.10520.2.1.1.32.1.2 | DisplayString | read-write | Description |
| I32 cps6000AlarmEntryDly | 1.3.6.1.4.1.10520.2.1.1.32.1.9 | Integer32 | read-write | Notify Delay |
| STR cps6000AlarmEntryDst | 1.3.6.1.4.1.10520.2.1.1.32.1.13 | DisplayString | read-write | Notify Destination |
| STR cps6000AlarmEntryFds | 1.3.6.1.4.1.10520.2.1.1.32.1.14 | DisplayString | read-write | Front Panel Description |
| STR cps6000AlarmEntryFth | 1.3.6.1.4.1.10520.2.1.1.32.1.7 | DisplayString | read-write | Float Threshold |
| INT cps6000AlarmEntryIndex | 1.3.6.1.4.1.10520.2.1.1.32.1.1 | INTEGER | read-only | Table Index |
| INT cps6000AlarmEntryNag | 1.3.6.1.4.1.10520.2.1.1.32.1.12 | INTEGER | read-write | Nag on Occur Values: no(0), yes(1) |
| INT cps6000AlarmEntryNoo | 1.3.6.1.4.1.10520.2.1.1.32.1.10 | INTEGER | read-write | Notify On Occur Values: no(0), yes(1) |
| INT cps6000AlarmEntryNor | 1.3.6.1.4.1.10520.2.1.1.32.1.11 | INTEGER | read-write | Notify On Retire Values: no(0), yes(1) |
| STR cps6000AlarmEntrySev | 1.3.6.1.4.1.10520.2.1.1.32.1.4 | DisplayString | read-write | Severity |
| STR cps6000AlarmEntryThr | 1.3.6.1.4.1.10520.2.1.1.32.1.6 | DisplayString | read-write | Threshold |
| cps6000AlarmTable | 1.3.6.1.4.1.10520.2.1.1.32 | not-accessible | Table of all Alarm data | |
| cps6000At1 | 1.3.6.1.4.1.10520.2.1.1.3 | |||
| STR cps6000At1Ata | 1.3.6.1.4.1.10520.2.1.1.3.13 | DisplayString | read-only | Alarm Test Active Value: Alarm report from ATA1 |
| STR cps6000At1Atb | 1.3.6.1.4.1.10520.2.1.1.3.14 | DisplayString | read-only | Alarm Test Aborted Value: Alarm report from ATB1 |
| STR cps6000At1Des | 1.3.6.1.4.1.10520.2.1.1.3.2 | DisplayString | read-write | Description |
| I32 cps6000At1Dur | 1.3.6.1.4.1.10520.2.1.1.3.6 | Integer32 | read-write | Alarm Contact Duration (Seconds) |
| STR cps6000At1Ems | 1.3.6.1.4.1.10520.2.1.1.3.16 | DisplayString | read-only | Email Test Results |
| INT cps6000At1Ets | 1.3.6.1.4.1.10520.2.1.1.3.15 | INTEGER | read-write | Do Email Test Values: start(1) |
| STR cps6000At1Ide | 1.3.6.1.4.1.10520.2.1.1.3.1 | DisplayString | read-only | Identifier |
| STR cps6000At1Irt | 1.3.6.1.4.1.10520.2.1.1.3.17 | DisplayString | read-write | Individual Relay Test State Values: , PMJ, PMN, R1, R2, R3, R4 |
| INT cps6000At1Lte | 1.3.6.1.4.1.10520.2.1.1.3.5 | INTEGER | read-write | Alarm Test Enable Values: disable(0), enable(1) |
| INT cps6000At1Pmj | 1.3.6.1.4.1.10520.2.1.1.3.7 | INTEGER | read-write | Power Major Values: no(0), yes(1) |
| INT cps6000At1Pmn | 1.3.6.1.4.1.10520.2.1.1.3.8 | INTEGER | read-write | Power Minor Values: no(0), yes(1) |
| INT cps6000At1R1 | 1.3.6.1.4.1.10520.2.1.1.3.9 | INTEGER | read-write | Test Relay 1 Values: no(0), yes(1) |
| INT cps6000At1R2 | 1.3.6.1.4.1.10520.2.1.1.3.10 | INTEGER | read-write | Test Relay 2 Values: no(0), yes(1) |
| INT cps6000At1R3 | 1.3.6.1.4.1.10520.2.1.1.3.11 | INTEGER | read-write | Test Relay 3 Values: no(0), yes(1) |
| INT cps6000At1R4 | 1.3.6.1.4.1.10520.2.1.1.3.12 | INTEGER | read-write | Test Relay 4 Values: no(0), yes(1) |
| STR cps6000At1Stg | 1.3.6.1.4.1.10520.2.1.1.3.4 | DisplayString | read-only | Stage |
| INT cps6000At1Stt | 1.3.6.1.4.1.10520.2.1.1.3.3 | INTEGER | read-write | Alarm Test Active Values: inactive(0), active(1) |
| cps6000Br1 | 1.3.6.1.4.1.10520.2.1.1.12 | |||
| STR cps6000Br1Adc | 1.3.6.1.4.1.10520.2.1.1.12.4 | DisplayString | read-only | Total Battery Current (Amps) |
| STR cps6000Br1Atd | 1.3.6.1.4.1.10520.2.1.1.12.16 | DisplayString | read-write | Auto Test Date |
| I32 cps6000Br1Ath | 1.3.6.1.4.1.10520.2.1.1.12.17 | Integer32 | read-write | Auto Test Hour |
| I32 cps6000Br1Atw | 1.3.6.1.4.1.10520.2.1.1.12.18 | Integer32 | read-write | Auto Test Minimum Hours after BD |
| STR cps6000Br1Bfa | 1.3.6.1.4.1.10520.2.1.1.12.27 | DisplayString | read-only | Battery Test Failed Value: Alarm report from BFA1 |
| STR cps6000Br1Bta | 1.3.6.1.4.1.10520.2.1.1.12.26 | DisplayString | read-only | Battery Test Active Value: Alarm report from BTA1 |
| STR cps6000Br1Bte | 1.3.6.1.4.1.10520.2.1.1.12.15 | DisplayString | read-write | Automatic Test Type Values: DISABLE, 20%, TIMED |
| STR cps6000Br1Btha | 1.3.6.1.4.1.10520.2.1.1.12.28 | DisplayString | read-only | High Battery Temperature Value: Alarm report from BTHA1 |
| STR cps6000Br1Btr | 1.3.6.1.4.1.10520.2.1.1.12.25 | DisplayString | read-only | Battery Test Results |
| INT cps6000Br1Bts | 1.3.6.1.4.1.10520.2.1.1.12.7 | INTEGER | read-write | Battery Test State Values: inactive(0), active(1) |
| I32 cps6000Br1Btv | 1.3.6.1.4.1.10520.2.1.1.12.22 | Integer32 | read-write | Battery Test Rectifier Voltage (mV) |
| STR cps6000Br1Cap | 1.3.6.1.4.1.10520.2.1.1.12.5 | DisplayString | read-only | Installed Battery Capacity (Amps) |
| I32 cps6000Br1Cev | 1.3.6.1.4.1.10520.2.1.1.12.24 | Integer32 | read-write | End Volts per Cell (mV) |
| INT cps6000Br1Cle | 1.3.6.1.4.1.10520.2.1.1.12.12 | INTEGER | read-write | Current Limit Enable Values: disable(0), enable(1) |
| I32 cps6000Br1Clt | 1.3.6.1.4.1.10520.2.1.1.12.13 | Integer32 | read-write | Current Limit Threshold (Amps) |
| STR cps6000Br1Des | 1.3.6.1.4.1.10520.2.1.1.12.2 | DisplayString | read-write | Description |
| STR cps6000Br1Hbt | 1.3.6.1.4.1.10520.2.1.1.12.3 | DisplayString | read-only | Highest Battery Temperature (C) |
| STR cps6000Br1Ide | 1.3.6.1.4.1.10520.2.1.1.12.1 | DisplayString | read-only | Identifier |
| STR cps6000Br1Isda | 1.3.6.1.4.1.10520.2.1.1.12.29 | DisplayString | read-only | Imminent Shutdown Value: Alarm report from ISD1 |
| STR cps6000Br1Mdp | 1.3.6.1.4.1.10520.2.1.1.12.30 | DisplayString | read-only | Voltage Duplicate ID Value: Alarm report from MDP1 |
| STR cps6000Br1Mtt | 1.3.6.1.4.1.10520.2.1.1.12.14 | DisplayString | read-write | Manual Test Type Values: DISABLE, 20%, TIMED |
| STR cps6000Br1Mzd | 1.3.6.1.4.1.10520.2.1.1.12.31 | DisplayString | read-only | Voltage ID Not Configured Value: Alarm report from MZD1 |
| I32 cps6000Br1Ntm | 1.3.6.1.4.1.10520.2.1.1.12.10 | Integer32 | read-only | Number of Temperature Probes Present |
| I32 cps6000Br1Nvm | 1.3.6.1.4.1.10520.2.1.1.12.11 | Integer32 | read-only | Number of Mid-cell V PresentTemperature |
| STR cps6000Br1Olcap | 1.3.6.1.4.1.10520.2.1.1.12.6 | DisplayString | read-only | On-line Battery Capacity (Amps) |
| INT cps6000Br1Scd | 1.3.6.1.4.1.10520.2.1.1.12.8 | INTEGER | read-write | Battery Voltage Imbalance Detection Values: disable(0), enable(1) |
| STR cps6000Br1Scda | 1.3.6.1.4.1.10520.2.1.1.12.32 | DisplayString | read-only | Shorted Cell Detected Value: Alarm report from SCD1 |
| I32 cps6000Br1Scv | 1.3.6.1.4.1.10520.2.1.1.12.9 | Integer32 | read-write | Battery Imbalance Threshold (mV) |
| I32 cps6000Br1Tev | 1.3.6.1.4.1.10520.2.1.1.12.21 | Integer32 | read-write | Manual Test Alarm Voltage (mV) |
| I32 cps6000Br1Tin | 1.3.6.1.4.1.10520.2.1.1.12.19 | Integer32 | read-write | Auto Test Interval (Months) |
| STR cps6000Br1Tmd | 1.3.6.1.4.1.10520.2.1.1.12.20 | DisplayString | read-write | Manual Test Duration |
| I32 cps6000Br1Tth | 1.3.6.1.4.1.10520.2.1.1.12.23 | Integer32 | read-write | High Temperature Threshold (C) |
| cps6000Bs1 | 1.3.6.1.4.1.10520.2.1.1.9 | |||
| I32 cps6000Bs1Amf | 1.3.6.1.4.1.10520.2.1.1.9.6 | Integer32 | read-write | Auto Multiplication Factor |
| STR cps6000Bs1Atm | 1.3.6.1.4.1.10520.2.1.1.9.4 | DisplayString | read-write | Auto Mode Values: OFF, QRCT, TIMED |
| STR cps6000Bs1Bsa | 1.3.6.1.4.1.10520.2.1.1.9.8 | DisplayString | read-only | Boost State Alarm Value: Alarm report from linked object |
| I32 cps6000Bs1Cta | 1.3.6.1.4.1.10520.2.1.1.9.7 | Integer32 | read-write | Current Terminated Current Threshold (Amps) |
| STR cps6000Bs1Des | 1.3.6.1.4.1.10520.2.1.1.9.2 | DisplayString | read-write | Description |
| STR cps6000Bs1Ide | 1.3.6.1.4.1.10520.2.1.1.9.1 | DisplayString | read-only | Identifier |
| STR cps6000Bs1Stt | 1.3.6.1.4.1.10520.2.1.1.9.3 | DisplayString | read-only | State Values: QRCT, MANUAL, BTP, TIMED AUTO, OFF |
| I32 cps6000Bs1Tmd | 1.3.6.1.4.1.10520.2.1.1.9.5 | Integer32 | read-write | Timed Manual Duration (Hours) |
| cps6000BtdEntry | 1.3.6.1.4.1.10520.2.1.1.11.1 | not-accessible | Entry of information for one Battery Type Definition | |
| STR cps6000BtdEntryBtc | 1.3.6.1.4.1.10520.2.1.1.11.1.5 | DisplayString | read-write | Battery Class Values: FLOODED, SEALED |
| STR cps6000BtdEntryBty | 1.3.6.1.4.1.10520.2.1.1.11.1.4 | DisplayString | read-write | Battery Type |
| STR cps6000BtdEntryCap | 1.3.6.1.4.1.10520.2.1.1.11.1.6 | DisplayString | read-write | Capacity (Amps) |
| STR cps6000BtdEntryDes | 1.3.6.1.4.1.10520.2.1.1.11.1.3 | DisplayString | read-write | Description |
| STR cps6000BtdEntryIde | 1.3.6.1.4.1.10520.2.1.1.11.1.2 | DisplayString | read-only | Identifier |
| INT cps6000BtdEntryIndex | 1.3.6.1.4.1.10520.2.1.1.11.1.1 | INTEGER | read-only | Table Index |
| cps6000BtdTable | 1.3.6.1.4.1.10520.2.1.1.11 | not-accessible | Table of all Battery Type Definition data | |
| cps6000Cb1 | 1.3.6.1.4.1.10520.2.1.1.22 | |||
| INT cps6000Cb1Br1 | 1.3.6.1.4.1.10520.2.1.1.22.5 | INTEGER | read-write | Connect Baudrate 1 Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) |
| INT cps6000Cb1Br2 | 1.3.6.1.4.1.10520.2.1.1.22.7 | INTEGER | read-write | Connect Baudrate 2 Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) |
| INT cps6000Cb1Br3 | 1.3.6.1.4.1.10520.2.1.1.22.9 | INTEGER | read-write | Connect Baudrate 3 Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) |
| INT cps6000Cb1Br4 | 1.3.6.1.4.1.10520.2.1.1.22.11 | INTEGER | read-write | Connect Baudrate 4 Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) |
| INT cps6000Cb1Br5 | 1.3.6.1.4.1.10520.2.1.1.22.13 | INTEGER | read-write | Connect Baudrate 5 Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) |
| STR cps6000Cb1Des | 1.3.6.1.4.1.10520.2.1.1.22.2 | DisplayString | read-write | Description |
| STR cps6000Cb1Ide | 1.3.6.1.4.1.10520.2.1.1.22.1 | DisplayString | read-only | Identifier |
| STR cps6000Cb1Ph1 | 1.3.6.1.4.1.10520.2.1.1.22.4 | DisplayString | read-write | Call-Back Phone Number 1 |
| STR cps6000Cb1Ph2 | 1.3.6.1.4.1.10520.2.1.1.22.6 | DisplayString | read-write | Call-Back Phone Number 2 |
| STR cps6000Cb1Ph3 | 1.3.6.1.4.1.10520.2.1.1.22.8 | DisplayString | read-write | Call-Back Phone Number 3 |
| STR cps6000Cb1Ph4 | 1.3.6.1.4.1.10520.2.1.1.22.10 | DisplayString | read-write | Call-Back Phone Number 4 |
| STR cps6000Cb1Ph5 | 1.3.6.1.4.1.10520.2.1.1.22.12 | DisplayString | read-write | Call-Back Phone Number 5 |
| INT cps6000Cb1Stt | 1.3.6.1.4.1.10520.2.1.1.22.3 | INTEGER | read-write | State Values: off(0), on(1) |
| cps6000CctEntry | 1.3.6.1.4.1.10520.2.1.1.40.1 | not-accessible | Entry of information for one Circuit | |
| STR cps6000CctEntryAdc | 1.3.6.1.4.1.10520.2.1.1.40.1.5 | DisplayString | read-only | Current (mA) |
| STR cps6000CctEntryAlr | 1.3.6.1.4.1.10520.2.1.1.40.1.23 | DisplayString | read-only | Actual Line Resistance (Ohms) |
| STR cps6000CctEntryCap | 1.3.6.1.4.1.10520.2.1.1.40.1.8 | DisplayString | read-only | Capacity (mA) |
| STR cps6000CctEntryCcd | 1.3.6.1.4.1.10520.2.1.1.40.1.12 | DisplayString | read-only | Comcode |
| INT cps6000CctEntryCfl | 1.3.6.1.4.1.10520.2.1.1.40.1.13 | INTEGER | read-only | Fail Values: inactive(0), active(1) |
| INT cps6000CctEntryCl | 1.3.6.1.4.1.10520.2.1.1.40.1.15 | INTEGER | read-only | Current Limit Values: inactive(0), active(1) |
| STR cps6000CctEntryCli | 1.3.6.1.4.1.10520.2.1.1.40.1.9 | DisplayString | read-only | CLEI Code |
| STR cps6000CctEntryDes | 1.3.6.1.4.1.10520.2.1.1.40.1.3 | DisplayString | read-write | Description |
| INT cps6000CctEntryGf | 1.3.6.1.4.1.10520.2.1.1.40.1.16 | INTEGER | read-only | Ground Fault Values: inactive(0), active(1) |
| STR cps6000CctEntryIde | 1.3.6.1.4.1.10520.2.1.1.40.1.2 | DisplayString | read-only | Identifier |
| STR cps6000CctEntryIlr | 1.3.6.1.4.1.10520.2.1.1.40.1.22 | DisplayString | read-only | Initial Line Resistance (Ohms) |
| INT cps6000CctEntryIndex | 1.3.6.1.4.1.10520.2.1.1.40.1.1 | INTEGER | read-only | Table Index |
| INT cps6000CctEntryLds | 1.3.6.1.4.1.10520.2.1.1.40.1.19 | INTEGER | read-only | Load Drop Status Values: inactive(0), active(1) |
| INT cps6000CctEntryLss | 1.3.6.1.4.1.10520.2.1.1.40.1.20 | INTEGER | read-only | Load Share Status Values: inactive(0), active(1) |
| INT cps6000CctEntryLts | 1.3.6.1.4.1.10520.2.1.1.40.1.21 | INTEGER | read-only | Line Test Status Values: inactive(0), active(1) |
| STR cps6000CctEntryMdl | 1.3.6.1.4.1.10520.2.1.1.40.1.11 | DisplayString | read-only | Model |
| INT cps6000CctEntryOt | 1.3.6.1.4.1.10520.2.1.1.40.1.18 | INTEGER | read-only | Over Temperature Values: inactive(0), active(1) |
| INT cps6000CctEntryOv | 1.3.6.1.4.1.10520.2.1.1.40.1.14 | INTEGER | read-only | Over Voltage Values: inactive(0), active(1) |
| STR cps6000CctEntrySnm | 1.3.6.1.4.1.10520.2.1.1.40.1.10 | DisplayString | read-only | Serial Number |
| STR cps6000CctEntryStt | 1.3.6.1.4.1.10520.2.1.1.40.1.6 | DisplayString | read-write | State Values: ON, STANDBY, MISSING, VACANT |
| STR cps6000CctEntryTmp | 1.3.6.1.4.1.10520.2.1.1.40.1.7 | DisplayString | read-only | Temperature (C) |
| INT cps6000CctEntryUv | 1.3.6.1.4.1.10520.2.1.1.40.1.17 | INTEGER | read-only | Under Voltage Values: inactive(0), active(1) |
| STR cps6000CctEntryVdc | 1.3.6.1.4.1.10520.2.1.1.40.1.4 | DisplayString | read-only | Voltage (Volts) |
| cps6000CctTable | 1.3.6.1.4.1.10520.2.1.1.40 | not-accessible | Table of all Circuit data | |
| cps6000Cm1 | 1.3.6.1.4.1.10520.2.1.1.17 | |||
| STR cps6000Cm1Cof | 1.3.6.1.4.1.10520.2.1.1.17.4 | DisplayString | read-only | Queue Overflow Value: Alarm report from COF1 |
| STR cps6000Cm1Cor | 1.3.6.1.4.1.10520.2.1.1.17.5 | DisplayString | read-only | Number Did Not Respond Value: Alarm report from COR1 |
| STR cps6000Cm1Des | 1.3.6.1.4.1.10520.2.1.1.17.2 | DisplayString | read-write | Description |
| STR cps6000Cm1Ide | 1.3.6.1.4.1.10520.2.1.1.17.1 | DisplayString | read-only | Identifier |
| I32 cps6000Cm1Ngi | 1.3.6.1.4.1.10520.2.1.1.17.3 | Integer32 | read-write | Nag Interval (Minutes) |
| STR cps6000Cm1Nnc | 1.3.6.1.4.1.10520.2.1.1.17.6 | DisplayString | read-only | Number Not Configured Value: Alarm report from NNC1 |
| cps6000CntEntry | 1.3.6.1.4.1.10520.2.1.1.13.1 | not-accessible | Entry of information for one Contactor | |
| STR cps6000CntEntryCnf | 1.3.6.1.4.1.10520.2.1.1.13.1.15 | DisplayString | read-only | Contactor Failed |
| STR cps6000CntEntryCno | 1.3.6.1.4.1.10520.2.1.1.13.1.14 | DisplayString | read-only | Contactor Open |
| INT cps6000CntEntryDam | 1.3.6.1.4.1.10520.2.1.1.13.1.8 | INTEGER | read-write | Disconnect Automode Values: none(0), voltage(1), voltageAndTime(2) |
| I32 cps6000CntEntryDdy | 1.3.6.1.4.1.10520.2.1.1.13.1.7 | Integer32 | read-write | Disconnect Delay (Minutes) |
| STR cps6000CntEntryDes | 1.3.6.1.4.1.10520.2.1.1.13.1.3 | DisplayString | read-write | Description |
| I32 cps6000CntEntryDth | 1.3.6.1.4.1.10520.2.1.1.13.1.6 | Integer32 | read-write | Disconnect Threshold (mV) |
| I32 cps6000CntEntryDtm | 1.3.6.1.4.1.10520.2.1.1.13.1.9 | Integer32 | read-only | Disconnect Time Remaining (Minutes) |
| INT cps6000CntEntryEna | 1.3.6.1.4.1.10520.2.1.1.13.1.5 | INTEGER | read-write | Control Values: disable(0), enable(1) |
| STR cps6000CntEntryIde | 1.3.6.1.4.1.10520.2.1.1.13.1.2 | DisplayString | read-only | Identifier |
| INT cps6000CntEntryIndex | 1.3.6.1.4.1.10520.2.1.1.13.1.1 | INTEGER | read-only | Table Index |
| INT cps6000CntEntryRam | 1.3.6.1.4.1.10520.2.1.1.13.1.12 | INTEGER | read-write | Reconnect Automode Values: none(0), voltage(1), voltageAndTime(2) |
| I32 cps6000CntEntryRdy | 1.3.6.1.4.1.10520.2.1.1.13.1.11 | Integer32 | read-write | Reconnect Delay (Seconds) |
| I32 cps6000CntEntryRth | 1.3.6.1.4.1.10520.2.1.1.13.1.10 | Integer32 | read-write | Reconnect Threshold (mV) |
| I32 cps6000CntEntryRtm | 1.3.6.1.4.1.10520.2.1.1.13.1.13 | Integer32 | read-only | Reconnect Time Remaining (Seconds) |
| STR cps6000CntEntryStt | 1.3.6.1.4.1.10520.2.1.1.13.1.4 | DisplayString | read-write | Status Values: NONE, DISCON, CONNECT, FAILED |
| cps6000CntTable | 1.3.6.1.4.1.10520.2.1.1.13 | not-accessible | Table of all Contactor data | |
| cps6000CoeEntry | 1.3.6.1.4.1.10520.2.1.1.19.1 | not-accessible | Entry of information for one Email Address | |
| STR cps6000CoeEntryAdr | 1.3.6.1.4.1.10520.2.1.1.19.1.4 | DisplayString | read-write | Email Address |
| STR cps6000CoeEntryDes | 1.3.6.1.4.1.10520.2.1.1.19.1.3 | DisplayString | read-write | Description |
| STR cps6000CoeEntryIde | 1.3.6.1.4.1.10520.2.1.1.19.1.2 | DisplayString | read-only | Identifier |
| INT cps6000CoeEntryIndex | 1.3.6.1.4.1.10520.2.1.1.19.1.1 | INTEGER | read-only | Table Index |
| STR cps6000CoeEntryTyp | 1.3.6.1.4.1.10520.2.1.1.19.1.5 | DisplayString | read-write | Address Type |
| cps6000CoeTable | 1.3.6.1.4.1.10520.2.1.1.19 | not-accessible | Table of all Email Address data | |
| cps6000CopEntry | 1.3.6.1.4.1.10520.2.1.1.18.1 | not-accessible | Entry of information for one Call Out Phone Number | |
| INT cps6000CopEntryBdr | 1.3.6.1.4.1.10520.2.1.1.18.1.6 | INTEGER | read-write | Connect Baudrate Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) |
| INT cps6000CopEntryDbt | 1.3.6.1.4.1.10520.2.1.1.18.1.7 | INTEGER | read-write | Data Bits Values: d7(7), d8(8) |
| STR cps6000CopEntryDes | 1.3.6.1.4.1.10520.2.1.1.18.1.3 | DisplayString | read-write | Description |
| I32 cps6000CopEntryDly | 1.3.6.1.4.1.10520.2.1.1.18.1.10 | Integer32 | read-write | Pager ID Delay |
| STR cps6000CopEntryIde | 1.3.6.1.4.1.10520.2.1.1.18.1.2 | DisplayString | read-only | Identifier |
| INT cps6000CopEntryIndex | 1.3.6.1.4.1.10520.2.1.1.18.1.1 | INTEGER | read-only | Table Index |
| STR cps6000CopEntryMsg | 1.3.6.1.4.1.10520.2.1.1.18.1.12 | DisplayString | read-write | Pager Message |
| STR cps6000CopEntryPgr | 1.3.6.1.4.1.10520.2.1.1.18.1.11 | DisplayString | read-write | Pager ID |
| STR cps6000CopEntryPhn | 1.3.6.1.4.1.10520.2.1.1.18.1.5 | DisplayString | read-write | Phone Number |
| STR cps6000CopEntryPry | 1.3.6.1.4.1.10520.2.1.1.18.1.8 | DisplayString | read-write | Parity Values: O, E, N |
| INT cps6000CopEntrySbt | 1.3.6.1.4.1.10520.2.1.1.18.1.9 | INTEGER | read-write | Stop Bits Values: s1(1), s2(2) |
| STR cps6000CopEntryTyp | 1.3.6.1.4.1.10520.2.1.1.18.1.4 | DisplayString | read-write | Type Values: DATA, PAGER |
| cps6000CopTable | 1.3.6.1.4.1.10520.2.1.1.18 | not-accessible | Table of all Call Out Phone Number data | |
| cps6000Cp1 | 1.3.6.1.4.1.10520.2.1.1.7 | |||
| STR cps6000Cp1Adc | 1.3.6.1.4.1.10520.2.1.1.7.4 | DisplayString | read-only | DC Current (Amps) |
| STR cps6000Cp1Cap | 1.3.6.1.4.1.10520.2.1.1.7.5 | DisplayString | read-only | Capacity (Amps) |
| STR cps6000Cp1Cfa | 1.3.6.1.4.1.10520.2.1.1.7.10 | DisplayString | read-only | Converter Fail Value: Alarm report from CFA1 |
| STR cps6000Cp1Cfj | 1.3.6.1.4.1.10520.2.1.1.7.15 | DisplayString | read-only | Converter Fan Major Value: Alarm report from CFJ1 |
| STR cps6000Cp1Cfn | 1.3.6.1.4.1.10520.2.1.1.7.14 | DisplayString | read-only | Converter Fan Minor Value: Alarm report from CFN1 |
| I32 cps6000Cp1Clm | 1.3.6.1.4.1.10520.2.1.1.7.24 | Integer32 | read-write | Current Limit (%) |
| STR cps6000Cp1Des | 1.3.6.1.4.1.10520.2.1.1.7.2 | DisplayString | read-write | Description |
| STR cps6000Cp1Dfa | 1.3.6.1.4.1.10520.2.1.1.7.11 | DisplayString | read-only | Distribution Fail Value: Alarm report from CDFA1 |
| STR cps6000Cp1Did | 1.3.6.1.4.1.10520.2.1.1.7.12 | DisplayString | read-only | ID Conflict Value: Alarm report from CDID1 |
| I32 cps6000Cp1Dth | 1.3.6.1.4.1.10520.2.1.1.7.7 | Integer32 | read-write | Low Voltage Disconnect (mV) |
| STR cps6000Cp1Hfv | 1.3.6.1.4.1.10520.2.1.1.7.18 | DisplayString | read-only | Converter High Voltage Minor Value: Alarm report from CHFV1 |
| STR cps6000Cp1Hva | 1.3.6.1.4.1.10520.2.1.1.7.17 | DisplayString | read-only | Converter High Voltage Major Value: Alarm report from CHVA1 |
| STR cps6000Cp1Icc | 1.3.6.1.4.1.10520.2.1.1.7.16 | DisplayString | read-only | Incompatible Converter Alarm Value: Alarm report from ICC1 |
| STR cps6000Cp1Ide | 1.3.6.1.4.1.10520.2.1.1.7.1 | DisplayString | read-only | Identifier |
| INT cps6000Cp1Lvd | 1.3.6.1.4.1.10520.2.1.1.7.9 | INTEGER | read-write | Low Voltage Disconnect Enable Values: disable(0), enable(1) |
| STR cps6000Cp1Mfa | 1.3.6.1.4.1.10520.2.1.1.7.13 | DisplayString | read-only | Multiple Converter Fail Value: Alarm report from CMFA1 |
| I32 cps6000Cp1Olcap | 1.3.6.1.4.1.10520.2.1.1.7.22 | Integer32 | read-only | Total On-line Converter Capacity (Amps) |
| STR cps6000Cp1Rl | 1.3.6.1.4.1.10520.2.1.1.7.20 | DisplayString | read-only | Converter Redundancy Loss Value: Alarm report from CRL1 |
| INT cps6000Cp1Rme | 1.3.6.1.4.1.10520.2.1.1.7.26 | INTEGER | read-write | Redundancy Monitor Values: disable(0), enable(1) |
| INT cps6000Cp1Rof | 1.3.6.1.4.1.10520.2.1.1.7.25 | INTEGER | read-write | Remote Turn Off Enable Values: disable(0), enable(1) |
| INT cps6000Cp1Rss | 1.3.6.1.4.1.10520.2.1.1.7.27 | INTEGER | read-write | Restart Values: restart(1) |
| I32 cps6000Cp1Rth | 1.3.6.1.4.1.10520.2.1.1.7.8 | Integer32 | read-write | Low Voltage Reconnect (mV) |
| STR cps6000Cp1Typ | 1.3.6.1.4.1.10520.2.1.1.7.21 | DisplayString | read-only | Type |
| STR cps6000Cp1Vdc | 1.3.6.1.4.1.10520.2.1.1.7.3 | DisplayString | read-only | DC Voltage (Volts) |
| STR cps6000Cp1Vla | 1.3.6.1.4.1.10520.2.1.1.7.19 | DisplayString | read-only | Converter Very Low Voltage Value: Alarm report from CVLA |
| I32 cps6000Cp1Vsd | 1.3.6.1.4.1.10520.2.1.1.7.23 | Integer32 | read-write | Voltage Shutdown (mV) |
| I32 cps6000Cp1Vsp | 1.3.6.1.4.1.10520.2.1.1.7.6 | Integer32 | read-write | Voltage Set Point (mV) |
| cps6000Dc1 | 1.3.6.1.4.1.10520.2.1.1.1 | |||
| STR cps6000Dc1Acf | 1.3.6.1.4.1.10520.2.1.1.1.35 | DisplayString | read-only | AC Fail Value: Alarm report from ACF1 |
| I32 cps6000Dc1Adc | 1.3.6.1.4.1.10520.2.1.1.1.6 | Integer32 | read-only | Current (Amps) |
| STR cps6000Dc1Amj | 1.3.6.1.4.1.10520.2.1.1.1.19 | DisplayString | read-only | Auxiliary Fuse Major Value: Alarm report from AMJ1 |
| STR cps6000Dc1Bda | 1.3.6.1.4.1.10520.2.1.1.1.42 | DisplayString | read-only | Battery On Discharge Value: Alarm report from BDA1 |
| STR cps6000Dc1Bdt | 1.3.6.1.4.1.10520.2.1.1.1.52 | DisplayString | read-only | BD Duration |
| STR cps6000Dc1Bod | 1.3.6.1.4.1.10520.2.1.1.1.15 | DisplayString | read-only | Battery On Discharge |
| STR cps6000Dc1Bst | 1.3.6.1.4.1.10520.2.1.1.1.18 | DisplayString | read-only | Boost |
| STR cps6000Dc1Bty | 1.3.6.1.4.1.10520.2.1.1.1.12 | DisplayString | read-only | Battery Type |
| I32 cps6000Dc1Cap | 1.3.6.1.4.1.10520.2.1.1.1.7 | Integer32 | read-only | Total Installed Rectifier Capacity (Amps) |
| STR cps6000Dc1Clm | 1.3.6.1.4.1.10520.2.1.1.1.33 | DisplayString | read-only | Rectifier Current Limit Value: Alarm report from CLM1 |
| STR cps6000Dc1Cma | 1.3.6.1.4.1.10520.2.1.1.1.28 | DisplayString | read-only | Minor Communication Failure Value: Alarm report from CMA1 |
| I32 cps6000Dc1Cps | 1.3.6.1.4.1.10520.2.1.1.1.11 | Integer32 | read-only | Cells per String |
| STR cps6000Dc1Des | 1.3.6.1.4.1.10520.2.1.1.1.2 | DisplayString | read-write | Description |
| STR cps6000Dc1Did | 1.3.6.1.4.1.10520.2.1.1.1.32 | DisplayString | read-only | ID Conflict Value: Alarm report from DID1 |
| STR cps6000Dc1Emd | 1.3.6.1.4.1.10520.2.1.1.1.50 | DisplayString | read-only | Energy Management Disabled Value: Alarm report from EMD1 |
| INT cps6000Dc1Eme | 1.3.6.1.4.1.10520.2.1.1.1.54 | INTEGER | read-write | Energy Management Enable Values: disable(0), enable(1) |
| I32 cps6000Dc1Emo | 1.3.6.1.4.1.10520.2.1.1.1.56 | Integer32 | read-write | Efficiency Rectifier Turn On Threshold (%) |
| STR cps6000Dc1Ems | 1.3.6.1.4.1.10520.2.1.1.1.53 | DisplayString | read-only | Energy Management State |
| I32 cps6000Dc1Emt | 1.3.6.1.4.1.10520.2.1.1.1.55 | Integer32 | read-write | Efficiency Target (%) |
| STR cps6000Dc1Epo | 1.3.6.1.4.1.10520.2.1.1.1.20 | DisplayString | read-only | Emergency Power Off Value: Alarm report from EPO1 |
| STR cps6000Dc1Faj | 1.3.6.1.4.1.10520.2.1.1.1.21 | DisplayString | read-only | External Fuse Major Value: Alarm report from FAJ1 |
| STR cps6000Dc1Fan | 1.3.6.1.4.1.10520.2.1.1.1.22 | DisplayString | read-only | External Fuse Minor Value: Alarm report from FAN1 |
| STR cps6000Dc1Hfv | 1.3.6.1.4.1.10520.2.1.1.1.44 | DisplayString | read-only | High Float Voltage Value: Alarm report from HFV1 |
| STR cps6000Dc1Hva | 1.3.6.1.4.1.10520.2.1.1.1.43 | DisplayString | read-only | High Voltage Value: Alarm report from HVA1 |
| STR cps6000Dc1Icr | 1.3.6.1.4.1.10520.2.1.1.1.48 | DisplayString | read-only | Incompatible Rectifier Value: Alarm report from ICR1 |
| STR cps6000Dc1Ide | 1.3.6.1.4.1.10520.2.1.1.1.1 | DisplayString | read-only | Identifier |
| INT cps6000Dc1Isd | 1.3.6.1.4.1.10520.2.1.1.1.14 | INTEGER | read-write | Imminent Shutdown Values: disable(0), enable(1) |
| STR cps6000Dc1Lsf | 1.3.6.1.4.1.10520.2.1.1.1.58 | DisplayString | read-only | Loadshare Fail Value: Alarm report from LSF1 |
| STR cps6000Dc1Macf | 1.3.6.1.4.1.10520.2.1.1.1.29 | DisplayString | read-only | Multiple AC Failure Value: Alarm report from MACF1 |
| STR cps6000Dc1Man | 1.3.6.1.4.1.10520.2.1.1.1.36 | DisplayString | read-only | Manual Off Value: Alarm report from MAN1 |
| STR cps6000Dc1Mcm | 1.3.6.1.4.1.10520.2.1.1.1.30 | DisplayString | read-only | Major Communication Failure Value: Alarm report from MCM1 |
| STR cps6000Dc1Mfa | 1.3.6.1.4.1.10520.2.1.1.1.38 | DisplayString | read-only | Multiple Rectifier Fail Value: Alarm report from MFA1 |
| INT cps6000Dc1Mls | 1.3.6.1.4.1.10520.2.1.1.1.51 | INTEGER | read-write | All Shunts Monitored Values: disable(0), enable(1) |
| STR cps6000Dc1Mman | 1.3.6.1.4.1.10520.2.1.1.1.37 | DisplayString | read-only | Multiple Manual Off Value: Alarm report from MMAN1 |
| I32 cps6000Dc1Nst | 1.3.6.1.4.1.10520.2.1.1.1.10 | Integer32 | read-only | Number of Strings |
| I32 cps6000Dc1Olcap | 1.3.6.1.4.1.10520.2.1.1.1.8 | Integer32 | read-only | Total On-line Rectifier Capacity (Amps) |
| STR cps6000Dc1Osa | 1.3.6.1.4.1.10520.2.1.1.1.24 | DisplayString | read-only | Open String Value: Alarm report from OSA1 |
| STR cps6000Dc1Poc | 1.3.6.1.4.1.10520.2.1.1.1.57 | DisplayString | read-only | Percent of Charge (%) |
| STR cps6000Dc1Rfa | 1.3.6.1.4.1.10520.2.1.1.1.31 | DisplayString | read-only | Rectifier Fail Value: Alarm report from RFA1 |
| STR cps6000Dc1Rfn | 1.3.6.1.4.1.10520.2.1.1.1.49 | DisplayString | read-only | Rectifier Fan Fail Value: Alarm report from RFN1 |
| STR cps6000Dc1Rls | 1.3.6.1.4.1.10520.2.1.1.1.41 | DisplayString | read-only | Redundancy Loss Value: Alarm report from RLS1 |
| I32 cps6000Dc1Ron | 1.3.6.1.4.1.10520.2.1.1.1.45 | Integer32 | read-write | External Standby |
| I32 cps6000Dc1Rot | 1.3.6.1.4.1.10520.2.1.1.1.17 | Integer32 | read-write | All Rectifier On Threshold |
| STR cps6000Dc1Rrtl | 1.3.6.1.4.1.10520.2.1.1.1.40 | DisplayString | read-only | Real-time Reserve Time Low Value: Alarm report from RRTL1 |
| INT cps6000Dc1Rsq | 1.3.6.1.4.1.10520.2.1.1.1.46 | INTEGER | read-write | Rectifier Sequencing Values: disable(0), enable(1) |
| INT cps6000Dc1Rss | 1.3.6.1.4.1.10520.2.1.1.1.16 | INTEGER | read-write | Rectifier Restart Values: off(0), on(1) |
| STR cps6000Dc1Rtl | 1.3.6.1.4.1.10520.2.1.1.1.39 | DisplayString | read-only | Reserve Time Low Value: Alarm report from RTL1 |
| STR cps6000Dc1Rtm | 1.3.6.1.4.1.10520.2.1.1.1.47 | DisplayString | read-only | Reserve Time |
| I32 cps6000Dc1Scap | 1.3.6.1.4.1.10520.2.1.1.1.9 | Integer32 | read-write | String Capacity (Amps) |
| STR cps6000Dc1Stt | 1.3.6.1.4.1.10520.2.1.1.1.4 | DisplayString | read-write | State Values: FLOAT, BOOST |
| STR cps6000Dc1Tpa | 1.3.6.1.4.1.10520.2.1.1.1.26 | DisplayString | read-only | Thermal Probe Alarm Value: Alarm report from TPA1 |
| I32 cps6000Dc1Trd | 1.3.6.1.4.1.10520.2.1.1.1.13 | Integer32 | read-only | Total Rectifier Drain (Amps) |
| STR cps6000Dc1Typ | 1.3.6.1.4.1.10520.2.1.1.1.3 | DisplayString | read-only | Type |
| I32 cps6000Dc1VdcEx | 1.3.6.1.4.1.10520.2.1.1.1.5 | Integer32 | read-only | Voltage (mV) |
| STR cps6000Dc1Vla | 1.3.6.1.4.1.10520.2.1.1.1.34 | DisplayString | read-only | Very Low Voltage Value: Alarm report from VLA1 |
| STR cps6000Dc1Vmf | 1.3.6.1.4.1.10520.2.1.1.1.27 | DisplayString | read-only | Voltage Module Fail Value: Alarm report from VMF1 |
| STR cps6000Dc1Vsf | 1.3.6.1.4.1.10520.2.1.1.1.23 | DisplayString | read-only | Sense/Control Fuse Value: Alarm report from VSF1 |
| STR cps6000Dc1Zid | 1.3.6.1.4.1.10520.2.1.1.1.25 | DisplayString | read-only | ID Not Configured Value: Alarm report from ZID1 |
| cps6000DccEntry | 1.3.6.1.4.1.10520.2.1.1.8.1 | not-accessible | Entry of information for one Converter | |
| STR cps6000DccEntryAdc | 1.3.6.1.4.1.10520.2.1.1.8.1.5 | DisplayString | read-only | DC Current (Amps) |
| STR cps6000DccEntryCap | 1.3.6.1.4.1.10520.2.1.1.8.1.6 | DisplayString | read-only | Capacity (Amps) |
| STR cps6000DccEntryCcf | 1.3.6.1.4.1.10520.2.1.1.8.1.11 | DisplayString | read-only | Communication Failure |
| STR cps6000DccEntryCfa | 1.3.6.1.4.1.10520.2.1.1.8.1.8 | DisplayString | read-only | Converter Fail |
| STR cps6000DccEntryCfn | 1.3.6.1.4.1.10520.2.1.1.8.1.12 | DisplayString | read-only | Fan Failure |
| STR cps6000DccEntryDes | 1.3.6.1.4.1.10520.2.1.1.8.1.3 | DisplayString | read-write | Description |
| STR cps6000DccEntryDfa | 1.3.6.1.4.1.10520.2.1.1.8.1.9 | DisplayString | read-only | Distribution Fuse Fail |
| STR cps6000DccEntryDid | 1.3.6.1.4.1.10520.2.1.1.8.1.10 | DisplayString | read-only | ID Conflict |
| STR cps6000DccEntryIde | 1.3.6.1.4.1.10520.2.1.1.8.1.2 | DisplayString | read-only | Identifier |
| INT cps6000DccEntryIndex | 1.3.6.1.4.1.10520.2.1.1.8.1.1 | INTEGER | read-only | Table Index |
| STR cps6000DccEntrySn | 1.3.6.1.4.1.10520.2.1.1.8.1.13 | DisplayString | read-only | Serial Number |
| STR cps6000DccEntryStt | 1.3.6.1.4.1.10520.2.1.1.8.1.7 | DisplayString | read-write | State Values: ON, OFF, STANDBY, VACANT |
| STR cps6000DccEntryTyp | 1.3.6.1.4.1.10520.2.1.1.8.1.4 | DisplayString | read-only | Type |
| cps6000DccTable | 1.3.6.1.4.1.10520.2.1.1.8 | not-accessible | Table of all Converter data | |
| cps6000DcmEntry | 1.3.6.1.4.1.10520.2.1.1.15.1 | not-accessible | Entry of information for one Distribution Current Monitor | |
| STR cps6000DcmEntryBrc | 1.3.6.1.4.1.10520.2.1.1.15.1.9 | DisplayString | read-only | Board Code |
| STR cps6000DcmEntryDes | 1.3.6.1.4.1.10520.2.1.1.15.1.3 | DisplayString | read-write | Description |
| STR cps6000DcmEntryIde | 1.3.6.1.4.1.10520.2.1.1.15.1.2 | DisplayString | read-only | Identifier |
| INT cps6000DcmEntryIndex | 1.3.6.1.4.1.10520.2.1.1.15.1.1 | INTEGER | read-only | Table Index |
| I32 cps6000DcmEntrySha | 1.3.6.1.4.1.10520.2.1.1.15.1.7 | Integer32 | read-write | Shunt Rating (Amps) |
| STR cps6000DcmEntrySn | 1.3.6.1.4.1.10520.2.1.1.15.1.8 | DisplayString | read-only | Serial Number |
| STR cps6000DcmEntryStt | 1.3.6.1.4.1.10520.2.1.1.15.1.4 | DisplayString | read-only | State Values: NONE, MISSING, PRESENT |
| STR cps6000DcmEntryTyp | 1.3.6.1.4.1.10520.2.1.1.15.1.5 | DisplayString | read-write | Shunt Type Values: NONE, LOAD, BATTERY |
| I32 cps6000DcmEntryVal | 1.3.6.1.4.1.10520.2.1.1.15.1.6 | Integer32 | read-only | Reading (Amps x 1000) |
| cps6000DcmTable | 1.3.6.1.4.1.10520.2.1.1.15 | not-accessible | Table of all Distribution Current Monitor data | |
| cps6000DcnEntry | 1.3.6.1.4.1.10520.2.1.1.14.1 | not-accessible | Entry of information for one Distribution Contactor Interface | |
| STR cps6000DcnEntryBrc | 1.3.6.1.4.1.10520.2.1.1.14.1.7 | DisplayString | read-only | Board Code |
| STR cps6000DcnEntryDes | 1.3.6.1.4.1.10520.2.1.1.14.1.3 | DisplayString | read-write | Description |
| STR cps6000DcnEntryIde | 1.3.6.1.4.1.10520.2.1.1.14.1.2 | DisplayString | read-only | Identifier |
| INT cps6000DcnEntryIndex | 1.3.6.1.4.1.10520.2.1.1.14.1.1 | INTEGER | read-only | Table Index |
| STR cps6000DcnEntrySn | 1.3.6.1.4.1.10520.2.1.1.14.1.6 | DisplayString | read-only | Serial Number |
| STR cps6000DcnEntryStt | 1.3.6.1.4.1.10520.2.1.1.14.1.4 | DisplayString | read-only | State Values: NONE, MISSING, PRESENT |
| STR cps6000DcnEntryTyp | 1.3.6.1.4.1.10520.2.1.1.14.1.5 | DisplayString | read-write | Contactor Interface Type Values: NONE, CN1, CN2, CN3, CN4 |
| cps6000DcnTable | 1.3.6.1.4.1.10520.2.1.1.14 | not-accessible | Table of all Distribution Contactor Interface data | |
| cps6000Dct1 | 1.3.6.1.4.1.10520.2.1.1.4 | |||
| STR cps6000Dct1Des | 1.3.6.1.4.1.10520.2.1.1.4.2 | DisplayString | read-write | Description |
| STR cps6000Dct1Ide | 1.3.6.1.4.1.10520.2.1.1.4.1 | DisplayString | read-only | Identifier |
| STR cps6000Dct1Src | 1.3.6.1.4.1.10520.2.1.1.4.3 | DisplayString | read-write | Source |
| cps6000DrcEntry | 1.3.6.1.4.1.10520.2.1.1.28.1 | not-accessible | Entry of information for one Derived Channel | |
| STR cps6000DrcEntryDes | 1.3.6.1.4.1.10520.2.1.1.28.1.3 | DisplayString | read-write | Description |
| STR cps6000DrcEntryIde | 1.3.6.1.4.1.10520.2.1.1.28.1.2 | DisplayString | read-only | Identifier |
| INT cps6000DrcEntryIndex | 1.3.6.1.4.1.10520.2.1.1.28.1.1 | INTEGER | read-only | Table Index |
| STR cps6000DrcEntryPrg | 1.3.6.1.4.1.10520.2.1.1.28.1.5 | DisplayString | read-write | Program Line |
| STR cps6000DrcEntryUni | 1.3.6.1.4.1.10520.2.1.1.28.1.6 | DisplayString | read-write | Unit |
| STR cps6000DrcEntryVal | 1.3.6.1.4.1.10520.2.1.1.28.1.4 | DisplayString | read-only | Value |
| cps6000DrcTable | 1.3.6.1.4.1.10520.2.1.1.28 | not-accessible | Table of all Derived Channel data | |
| cps6000Ft1 | 1.3.6.1.4.1.10520.2.1.1.37 | |||
| STR cps6000Ft1Cbt | 1.3.6.1.4.1.10520.2.1.1.37.11 | DisplayString | read-only | Circuit Breaker Trip |
| STR cps6000Ft1Ctf | 1.3.6.1.4.1.10520.2.1.1.37.12 | DisplayString | read-only | Circuit Fail |
| STR cps6000Ft1Des | 1.3.6.1.4.1.10520.2.1.1.37.2 | DisplayString | read-only | Description |
| STR cps6000Ft1Fmi | 1.3.6.1.4.1.10520.2.1.1.37.7 | DisplayString | read-only | Fan Fail Minor |
| STR cps6000Ft1Fmj | 1.3.6.1.4.1.10520.2.1.1.37.8 | DisplayString | read-only | Fan Fail Major |
| STR cps6000Ft1Iadc | 1.3.6.1.4.1.10520.2.1.1.37.4 | DisplayString | read-only | Input Current (Amps) |
| STR cps6000Ft1Ide | 1.3.6.1.4.1.10520.2.1.1.37.1 | DisplayString | read-only | Identifier |
| STR cps6000Ft1Ipi | 1.3.6.1.4.1.10520.2.1.1.37.9 | DisplayString | read-only | Input Power Minor |
| STR cps6000Ft1Ipj | 1.3.6.1.4.1.10520.2.1.1.37.10 | DisplayString | read-only | Input Power Major |
| STR cps6000Ft1Lda | 1.3.6.1.4.1.10520.2.1.1.37.15 | DisplayString | read-only | Load Drop Alarm |
| STR cps6000Ft1Lor | 1.3.6.1.4.1.10520.2.1.1.37.14 | DisplayString | read-only | Loss of Redundancy |
| STR cps6000Ft1Lsa | 1.3.6.1.4.1.10520.2.1.1.37.16 | DisplayString | read-only | Load Share Alarm |
| STR cps6000Ft1Lta | 1.3.6.1.4.1.10520.2.1.1.37.17 | DisplayString | read-only | Line Test Failed Alarm |
| INT cps6000Ft1Lte | 1.3.6.1.4.1.10520.2.1.1.37.5 | INTEGER | read-only | Line Test Enable Values: disable(0), enable(1) |
| STR cps6000Ft1Ltf | 1.3.6.1.4.1.10520.2.1.1.37.6 | DisplayString | read-only | Line Test Frequency (Days) |
| STR cps6000Ft1Mctf | 1.3.6.1.4.1.10520.2.1.1.37.13 | DisplayString | read-only | Multiple Circuit Fail |
| INT cps6000Ft1Rem | 1.3.6.1.4.1.10520.2.1.1.37.18 | INTEGER | read-write | Restart Faulted Circuits Values: disable(0), enable(1) |
| STR cps6000Ft1Stt | 1.3.6.1.4.1.10520.2.1.1.37.3 | DisplayString | read-only | State Values: PRESENT, NONE |
| INT cps6000Ft1Tof | 1.3.6.1.4.1.10520.2.1.1.37.19 | INTEGER | read-write | Turn Off Circuits Values: disabled(0), faulted(1), faultedAndNoLoad(2) |
| cps6000Gm1 | 1.3.6.1.4.1.10520.2.1.1.5 | |||
| I32 cps6000Gm1Bcl | 1.3.6.1.4.1.10520.2.1.1.5.9 | Integer32 | read-write | Boost Current Limit (%) |
| I32 cps6000Gm1Bsd | 1.3.6.1.4.1.10520.2.1.1.5.5 | Integer32 | read-write | Boost High Voltage Shutdown (mV) |
| I32 cps6000Gm1Bsp | 1.3.6.1.4.1.10520.2.1.1.5.7 | Integer32 | read-write | Boost Set Point (mV) |
| STR cps6000Gm1Des | 1.3.6.1.4.1.10520.2.1.1.5.2 | DisplayString | read-write | Description |
| I32 cps6000Gm1Fcl | 1.3.6.1.4.1.10520.2.1.1.5.8 | Integer32 | read-write | Float Current Limit (%) |
| I32 cps6000Gm1Fsd | 1.3.6.1.4.1.10520.2.1.1.5.4 | Integer32 | read-write | Float High Voltage Shutdown (mV) |
| I32 cps6000Gm1Fsp | 1.3.6.1.4.1.10520.2.1.1.5.6 | Integer32 | read-write | Float Set Point (mV) |
| STR cps6000Gm1Ide | 1.3.6.1.4.1.10520.2.1.1.5.1 | DisplayString | read-only | Identifier |
| INT cps6000Gm1Lse | 1.3.6.1.4.1.10520.2.1.1.5.3 | INTEGER | read-write | Load Share Enable Values: disable(0), enable(1) |
| INT cps6000Gm1Rme | 1.3.6.1.4.1.10520.2.1.1.5.10 | INTEGER | read-write | Redundancy Monitor Values: disable(0), enable(1) |
| cps6000GrpEntry | 1.3.6.1.4.1.10520.2.1.1.38.1 | not-accessible | Entry of information for one Circuit Group | |
| STR cps6000GrpEntryAadc | 1.3.6.1.4.1.10520.2.1.1.38.1.6 | DisplayString | read-only | Average Current (mA) |
| STR cps6000GrpEntryCap | 1.3.6.1.4.1.10520.2.1.1.38.1.7 | DisplayString | read-only | Capacity (mA) |
| STR cps6000GrpEntryCct | 1.3.6.1.4.1.10520.2.1.1.38.1.4 | DisplayString | read-only | Circuits |
| STR cps6000GrpEntryDes | 1.3.6.1.4.1.10520.2.1.1.38.1.3 | DisplayString | read-write | Description |
| STR cps6000GrpEntryIde | 1.3.6.1.4.1.10520.2.1.1.38.1.2 | DisplayString | read-only | Identifier |
| INT cps6000GrpEntryIndex | 1.3.6.1.4.1.10520.2.1.1.38.1.1 | INTEGER | read-only | Table Index |
| STR cps6000GrpEntryLrs | 1.3.6.1.4.1.10520.2.1.1.38.1.8 | DisplayString | read-only | Loss of Redundancy Status |
| STR cps6000GrpEntryOlcap | 1.3.6.1.4.1.10520.2.1.1.38.1.9 | DisplayString | read-only | Online Capacity (mA) |
| STR cps6000GrpEntryTadc | 1.3.6.1.4.1.10520.2.1.1.38.1.5 | DisplayString | read-only | Total Current (mA) |
| cps6000GrpTable | 1.3.6.1.4.1.10520.2.1.1.38 | not-accessible | Table of all Circuit Group data | |
| cps6000InpEntry | 1.3.6.1.4.1.10520.2.1.1.29.1 | not-accessible | Entry of information for one Input Management | |
| STR cps6000InpEntryBrc | 1.3.6.1.4.1.10520.2.1.1.29.1.8 | DisplayString | read-only | Board Code |
| STR cps6000InpEntryDes | 1.3.6.1.4.1.10520.2.1.1.29.1.3 | DisplayString | read-write | Description |
| STR cps6000InpEntryIde | 1.3.6.1.4.1.10520.2.1.1.29.1.2 | DisplayString | read-only | Identifier |
| INT cps6000InpEntryIndex | 1.3.6.1.4.1.10520.2.1.1.29.1.1 | INTEGER | read-only | Table Index |
| STR cps6000InpEntryPol | 1.3.6.1.4.1.10520.2.1.1.29.1.6 | DisplayString | read-write | Input Alarming Polarity Values: OPEN, CLOSED |
| STR cps6000InpEntrySn | 1.3.6.1.4.1.10520.2.1.1.29.1.7 | DisplayString | read-only | Serial Number |
| INT cps6000InpEntryStt | 1.3.6.1.4.1.10520.2.1.1.29.1.4 | INTEGER | read-only | Input State Values: alarming(1), nonAlarming(0) |
| STR cps6000InpEntryTyp | 1.3.6.1.4.1.10520.2.1.1.29.1.5 | DisplayString | read-write | Type Alarm Object ID or, REMLVD for Remote LVD |
| cps6000InpTable | 1.3.6.1.4.1.10520.2.1.1.29 | not-accessible | Table of all Input Management data | |
| cps6000Lp1 | 1.3.6.1.4.1.10520.2.1.1.24 | |||
| STR cps6000Lp1App | 1.3.6.1.4.1.10520.2.1.1.24.10 | DisplayString | read-write | Application Values: TERMINAL, TL1, EVENT LOG |
| STR cps6000Lp1Bdr | 1.3.6.1.4.1.10520.2.1.1.24.4 | DisplayString | read-write | Baudrate Values: 300, 1200, 2400, 4800, 9600, 19200, AUTO |
| INT cps6000Lp1Dbt | 1.3.6.1.4.1.10520.2.1.1.24.5 | INTEGER | read-write | Data Bits Values: d7(7), d8(8) |
| STR cps6000Lp1Des | 1.3.6.1.4.1.10520.2.1.1.24.2 | DisplayString | read-write | Description |
| STR cps6000Lp1Hsh | 1.3.6.1.4.1.10520.2.1.1.24.9 | DisplayString | read-write | Handshaking Values: NO, HW, SW |
| STR cps6000Lp1Ide | 1.3.6.1.4.1.10520.2.1.1.24.1 | DisplayString | read-only | Identifier |
| STR cps6000Lp1Pry | 1.3.6.1.4.1.10520.2.1.1.24.6 | DisplayString | read-write | Parity Values: O, E, N |
| INT cps6000Lp1Sbt | 1.3.6.1.4.1.10520.2.1.1.24.7 | INTEGER | read-write | Stop Bits Values: s1(1), s2(2) |
| STR cps6000Lp1Stt | 1.3.6.1.4.1.10520.2.1.1.24.3 | DisplayString | read-only | State |
| I32 cps6000Lp1Tmo | 1.3.6.1.4.1.10520.2.1.1.24.8 | Integer32 | read-write | Time-Out (Minutes) |
| INT cps6000Lp1Wre | 1.3.6.1.4.1.10520.2.1.1.24.11 | INTEGER | read-write | Write Enable Values: disable(0), enable(1) |
| cps6000Mp1 | 1.3.6.1.4.1.10520.2.1.1.23 | |||
| INT cps6000Mp1Bdr | 1.3.6.1.4.1.10520.2.1.1.23.5 | INTEGER | read-write | Baudrate Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) |
| INT cps6000Mp1Dbt | 1.3.6.1.4.1.10520.2.1.1.23.4 | INTEGER | read-write | Data Bits Values: d7(7), d8(8) |
| STR cps6000Mp1Des | 1.3.6.1.4.1.10520.2.1.1.23.2 | DisplayString | read-write | Description |
| STR cps6000Mp1Hsh | 1.3.6.1.4.1.10520.2.1.1.23.9 | DisplayString | read-write | Handshaking Values: NO, SW |
| STR cps6000Mp1Ide | 1.3.6.1.4.1.10520.2.1.1.23.1 | DisplayString | read-only | Identifier |
| STR cps6000Mp1Ins | 1.3.6.1.4.1.10520.2.1.1.23.12 | DisplayString | read-write | Modem Init String |
| I32 cps6000Mp1Nrg | 1.3.6.1.4.1.10520.2.1.1.23.10 | Integer32 | read-write | Number of Rings Before Answer |
| STR cps6000Mp1Pry | 1.3.6.1.4.1.10520.2.1.1.23.6 | DisplayString | read-write | Parity Values: O, E, N |
| INT cps6000Mp1Sbt | 1.3.6.1.4.1.10520.2.1.1.23.7 | INTEGER | read-write | Stop Bits Values: s1(1), s2(2) |
| STR cps6000Mp1Stt | 1.3.6.1.4.1.10520.2.1.1.23.3 | DisplayString | read-only | State |
| I32 cps6000Mp1Tmo | 1.3.6.1.4.1.10520.2.1.1.23.8 | Integer32 | read-write | Time-Out (Minutes) |
| INT cps6000Mp1Wre | 1.3.6.1.4.1.10520.2.1.1.23.11 | INTEGER | read-write | Write Enable Values: disable(0), enable(1) |
| cps6000MsvEntry | 1.3.6.1.4.1.10520.2.1.1.36.1 | not-accessible | Entry of information for one Midstring Voltage Monitor | |
| STR cps6000MsvEntryDes | 1.3.6.1.4.1.10520.2.1.1.36.1.3 | DisplayString | read-write | Description |
| STR cps6000MsvEntryDid | 1.3.6.1.4.1.10520.2.1.1.36.1.6 | DisplayString | read-only | ID Conflict |
| STR cps6000MsvEntryIde | 1.3.6.1.4.1.10520.2.1.1.36.1.2 | DisplayString | read-only | Identifier |
| INT cps6000MsvEntryIndex | 1.3.6.1.4.1.10520.2.1.1.36.1.1 | INTEGER | read-only | Table Index |
| STR cps6000MsvEntryStt | 1.3.6.1.4.1.10520.2.1.1.36.1.4 | DisplayString | read-only | State |
| STR cps6000MsvEntryVal | 1.3.6.1.4.1.10520.2.1.1.36.1.5 | DisplayString | read-only | Value (Volts) |
| cps6000MsvTable | 1.3.6.1.4.1.10520.2.1.1.36 | not-accessible | Table of all Midstring Voltage Monitor data | |
| cps6000Net1 | 1.3.6.1.4.1.10520.2.1.1.27 | |||
| STR cps6000Net1Des | 1.3.6.1.4.1.10520.2.1.1.27.2 | DisplayString | read-write | Description |
| INT cps6000Net1Dhcp | 1.3.6.1.4.1.10520.2.1.1.27.4 | INTEGER | read-write | DHCP Values: disable(0), enable(1) |
| STR cps6000Net1Dns | 1.3.6.1.4.1.10520.2.1.1.27.11 | DisplayString | read-write | DNS Server Address |
| STR cps6000Net1Dom | 1.3.6.1.4.1.10520.2.1.1.27.10 | DisplayString | read-write | Domain Name |
| STR cps6000Net1Ead | 1.3.6.1.4.1.10520.2.1.1.27.3 | DisplayString | read-only | Ethernet Address |
| STR cps6000Net1Gtwy | 1.3.6.1.4.1.10520.2.1.1.27.8 | DisplayString | read-write | Default Gateway |
| STR cps6000Net1Host | 1.3.6.1.4.1.10520.2.1.1.27.9 | DisplayString | read-write | Host Name |
| STR cps6000Net1Ide | 1.3.6.1.4.1.10520.2.1.1.27.1 | DisplayString | read-only | Identifier |
| STR cps6000Net1Ip | 1.3.6.1.4.1.10520.2.1.1.27.5 | DisplayString | read-write | Static IP Address |
| STR cps6000Net1Msrv | 1.3.6.1.4.1.10520.2.1.1.27.14 | DisplayString | read-write | Mail Server Address |
| STR cps6000Net1Sub | 1.3.6.1.4.1.10520.2.1.1.27.7 | DisplayString | read-write | Subnet Mask |
| I32 cps6000Net1Tmo | 1.3.6.1.4.1.10520.2.1.1.27.13 | Integer32 | read-write | Timeout (Minutes) |
| STR cps6000Net1Wip | 1.3.6.1.4.1.10520.2.1.1.27.6 | DisplayString | read-only | Working IP Address |
| INT cps6000Net1Wre | 1.3.6.1.4.1.10520.2.1.1.27.12 | INTEGER | read-write | Write Enable Values: disable(0), enable(1) |
| cps6000Po1 | 1.3.6.1.4.1.10520.2.1.1.21 | |||
| INT cps6000Po1Bdr | 1.3.6.1.4.1.10520.2.1.1.21.4 | INTEGER | read-write | Connect Baudrate Values: b300(300), b1200(1200), b2400(2400), b4800(4800), b9600(9600), b19200(19200) |
| STR cps6000Po1Cl01 | 1.3.6.1.4.1.10520.2.1.1.21.10 | DisplayString | read-write | Command Line 1 |
| STR cps6000Po1Cl02 | 1.3.6.1.4.1.10520.2.1.1.21.11 | DisplayString | read-write | Command Line 2 |
| STR cps6000Po1Cl03 | 1.3.6.1.4.1.10520.2.1.1.21.12 | DisplayString | read-write | Command Line 3 |
| STR cps6000Po1Cl04 | 1.3.6.1.4.1.10520.2.1.1.21.13 | DisplayString | read-write | Command Line 4 |
| STR cps6000Po1Cl05 | 1.3.6.1.4.1.10520.2.1.1.21.14 | DisplayString | read-write | Command Line 5 |
| STR cps6000Po1Cl06 | 1.3.6.1.4.1.10520.2.1.1.21.15 | DisplayString | read-write | Command Line 6 |
| STR cps6000Po1Cl07 | 1.3.6.1.4.1.10520.2.1.1.21.16 | DisplayString | read-write | Command Line 7 |
| STR cps6000Po1Cl08 | 1.3.6.1.4.1.10520.2.1.1.21.17 | DisplayString | read-write | Command Line 8 |
| STR cps6000Po1Cl09 | 1.3.6.1.4.1.10520.2.1.1.21.18 | DisplayString | read-write | Command Line 9 |
| STR cps6000Po1Cl10 | 1.3.6.1.4.1.10520.2.1.1.21.19 | DisplayString | read-write | Command Line 10 |
| INT cps6000Po1Dbt | 1.3.6.1.4.1.10520.2.1.1.21.5 | INTEGER | read-write | Data Bits Values: d7(7), d8(8) |
| STR cps6000Po1Des | 1.3.6.1.4.1.10520.2.1.1.21.2 | DisplayString | read-write | Description |
| STR cps6000Po1Ide | 1.3.6.1.4.1.10520.2.1.1.21.1 | DisplayString | read-only | Identifier |
| STR cps6000Po1Int | 1.3.6.1.4.1.10520.2.1.1.21.8 | DisplayString | read-write | Interval Values: Sunday, Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Daily, Monthly, Quarterly, Never |
| STR cps6000Po1Phn | 1.3.6.1.4.1.10520.2.1.1.21.3 | DisplayString | read-write | Phone Number |
| STR cps6000Po1Por | 1.3.6.1.4.1.10520.2.1.1.21.20 | DisplayString | read-only | Number Did Not Respond Value: Alarm report from POR1 |
| STR cps6000Po1Pry | 1.3.6.1.4.1.10520.2.1.1.21.6 | DisplayString | read-write | Parity Values: O, E, N |
| INT cps6000Po1Sbt | 1.3.6.1.4.1.10520.2.1.1.21.7 | INTEGER | read-write | Stop Bits Values: s1(1), s2(2) |
| STR cps6000Po1Tim | 1.3.6.1.4.1.10520.2.1.1.21.9 | DisplayString | read-write | Time |
| cps6000Ps1 | 1.3.6.1.4.1.10520.2.1.1.2 | |||
| STR cps6000Ps1Amt | 1.3.6.1.4.1.10520.2.1.1.2.20 | DisplayString | read-only | Ambient Temperature (C) |
| STR cps6000Ps1Amth | 1.3.6.1.4.1.10520.2.1.1.2.26 | DisplayString | read-only | High Ambient Temperature Value: Alarm report from AMTH1 |
| STR cps6000Ps1Amtl | 1.3.6.1.4.1.10520.2.1.1.2.27 | DisplayString | read-only | Low Ambient Temperature Value: Alarm report from AMTL1 |
| STR cps6000Ps1Ast | 1.3.6.1.4.1.10520.2.1.1.2.51 | DisplayString | read-only | System Alarm State |
| STR cps6000Ps1Ax1 | 1.3.6.1.4.1.10520.2.1.1.2.38 | DisplayString | read-only | Auxilliary Event 1 Value: Alarm report from AUX1 |
| STR cps6000Ps1Ax2 | 1.3.6.1.4.1.10520.2.1.1.2.39 | DisplayString | read-only | Auxilliary Event 1 Value: Alarm report from AUX2 |
| STR cps6000Ps1Ax3 | 1.3.6.1.4.1.10520.2.1.1.2.40 | DisplayString | read-only | Auxilliary Event 1 Value: Alarm report from AUX3 |
| STR cps6000Ps1Ax4 | 1.3.6.1.4.1.10520.2.1.1.2.41 | DisplayString | read-only | Auxilliary Event 1 Value: Alarm report from AUX4 |
| STR cps6000Ps1Ax5 | 1.3.6.1.4.1.10520.2.1.1.2.42 | DisplayString | read-only | Auxilliary Event 1 Value: Alarm report from AUX5 |
| STR cps6000Ps1Ax6 | 1.3.6.1.4.1.10520.2.1.1.2.43 | DisplayString | read-only | Auxilliary Event 1 Value: Alarm report from AUX6 |
| STR cps6000Ps1Bbl | 1.3.6.1.4.1.10520.2.1.1.2.28 | DisplayString | read-only | Memory Backup Battery Low Value: Alarm report from BBL1 |
| STR cps6000Ps1Brc | 1.3.6.1.4.1.10520.2.1.1.2.10 | DisplayString | read-only | Board Code |
| STR cps6000Ps1Cch | 1.3.6.1.4.1.10520.2.1.1.2.29 | DisplayString | read-only | Configuration Changed Value: Alarm report from CCH1 |
| STR cps6000Ps1Clc | 1.3.6.1.4.1.10520.2.1.1.2.30 | DisplayString | read-only | Clock Changed Value: Alarm report from CLC1 |
| STR cps6000Ps1Dat | 1.3.6.1.4.1.10520.2.1.1.2.13 | DisplayString | read-write | System Date |
| STR cps6000Ps1Des | 1.3.6.1.4.1.10520.2.1.1.2.2 | DisplayString | read-write | Description |
| STR cps6000Ps1Dflt | 1.3.6.1.4.1.10520.2.1.1.2.9 | DisplayString | read-only | Defaults Version |
| INT cps6000Ps1Dls | 1.3.6.1.4.1.10520.2.1.1.2.17 | INTEGER | read-write | Daylight Savings Values: off(0), on(1) |
| STR cps6000Ps1Dse | 1.3.6.1.4.1.10520.2.1.1.2.53 | DisplayString | read-write | Daylight Saving End mon:wk:dow:min or, mon:-1:dom:min |
| STR cps6000Ps1Dss | 1.3.6.1.4.1.10520.2.1.1.2.52 | DisplayString | read-write | Daylight Saving Start mon:wk:dow:min or, mon:-1:dom:min |
| STR cps6000Ps1Dtf | 1.3.6.1.4.1.10520.2.1.1.2.14 | DisplayString | read-write | Date Format Values: mm/dd/yyyy, dd/mm/yyyy, yyyy/mm/dd |
| STR cps6000Ps1Epr | 1.3.6.1.4.1.10520.2.1.1.2.31 | DisplayString | read-only | External Password Reset Value: Alarm report from EPR1 |
| STR cps6000Ps1Exl | 1.3.6.1.4.1.10520.2.1.1.2.32 | DisplayString | read-only | Excessive Login Attempts Value: Alarm report from EXL1 |
| INT cps6000Ps1Fpc | 1.3.6.1.4.1.10520.2.1.1.2.24 | INTEGER | read-write | Front Panel Configuration Values: disable(0), enable(1) |
| INT cps6000Ps1Fpe | 1.3.6.1.4.1.10520.2.1.1.2.49 | INTEGER | read-write | Front Panel Pin Enable Values: disable(0), enable(1) |
| I32 cps6000Ps1Fpt | 1.3.6.1.4.1.10520.2.1.1.2.50 | Integer32 | read-write | Front Panel Pin Timeout |
| STR cps6000Ps1Fst | 1.3.6.1.4.1.10520.2.1.1.2.47 | DisplayString | read-write | Factory Defaults |
| STR cps6000Ps1Fstl | 1.3.6.1.4.1.10520.2.1.1.2.48 | DisplayString | read-only | Factory Defaults List |
| STR cps6000Ps1Hcl | 1.3.6.1.4.1.10520.2.1.1.2.33 | DisplayString | read-only | History Cleared Value: Alarm report from HCL1 |
| STR cps6000Ps1Ide | 1.3.6.1.4.1.10520.2.1.1.2.1 | DisplayString | read-only | Identifier |
| STR cps6000Ps1Lng | 1.3.6.1.4.1.10520.2.1.1.2.18 | DisplayString | read-write | Front Panel Language |
| STR cps6000Ps1Lngl | 1.3.6.1.4.1.10520.2.1.1.2.46 | DisplayString | read-only | Available Languages |
| STR cps6000Ps1Pfd | 1.3.6.1.4.1.10520.2.1.1.2.34 | DisplayString | read-only | Passwords At Default Value: Alarm report from PFD1 |
| STR cps6000Ps1Pgi | 1.3.6.1.4.1.10520.2.1.1.2.37 | DisplayString | read-only | Program Line Invalid Value: Alarm report from PGI1 |
| STR cps6000Ps1Pht | 1.3.6.1.4.1.10520.2.1.1.2.35 | DisplayString | read-only | Processor Halt Value: Alarm report from PHT1 |
| INT cps6000Ps1Poe | 1.3.6.1.4.1.10520.2.1.1.2.23 | INTEGER | read-write | Power Off Enable Values: disable(0), enable(1) |
| STR cps6000Ps1Ptt | 1.3.6.1.4.1.10520.2.1.1.2.19 | DisplayString | read-write | Communication Port Type Values: LOCAL, MODEM |
| INT cps6000Ps1Rrf | 1.3.6.1.4.1.10520.2.1.1.2.25 | INTEGER | read-write | Remote Rectifier Off Values: disable(0), enable(1) |
| INT cps6000Ps1Rss | 1.3.6.1.4.1.10520.2.1.1.2.44 | INTEGER | read-write | Restart Devices Values: restart(1) |
| STR cps6000Ps1Sde | 1.3.6.1.4.1.10520.2.1.1.2.4 | DisplayString | read-write | Site Description |
| STR cps6000Ps1Sid | 1.3.6.1.4.1.10520.2.1.1.2.3 | DisplayString | read-write | Site ID |
| STR cps6000Ps1Sn | 1.3.6.1.4.1.10520.2.1.1.2.11 | DisplayString | read-only | Serial Number |
| STR cps6000Ps1Stf | 1.3.6.1.4.1.10520.2.1.1.2.36 | DisplayString | read-only | Self Test Failed Value: Alarm report from STF1 |
| STR cps6000Ps1Swv | 1.3.6.1.4.1.10520.2.1.1.2.5 | DisplayString | read-only | Software Version |
| STR cps6000Ps1Sys | 1.3.6.1.4.1.10520.2.1.1.2.45 | DisplayString | read-write | System Description |
| STR cps6000Ps1Tim | 1.3.6.1.4.1.10520.2.1.1.2.15 | DisplayString | read-write | System Time |
| INT cps6000Ps1Tmf | 1.3.6.1.4.1.10520.2.1.1.2.16 | INTEGER | read-write | System Time Format Values: h12(12), h24(24) |
| STR cps6000Ps1Tun | 1.3.6.1.4.1.10520.2.1.1.2.21 | DisplayString | read-write | Temperature Units Values: C, F |
| INT cps6000Ps1Usl | 1.3.6.1.4.1.10520.2.1.1.2.12 | INTEGER | read-write | Uninstall Missing Equipment Values: uninstall(1) |
| INT cps6000Ps1Usr | 1.3.6.1.4.1.10520.2.1.1.2.22 | INTEGER | read-write | Enable User Accounts Values: disable(0), enable(1) |
| STR cps6000Ps1Verb | 1.3.6.1.4.1.10520.2.1.1.2.6 | DisplayString | read-only | Boot Block Version |
| STR cps6000Ps1Verd | 1.3.6.1.4.1.10520.2.1.1.2.8 | DisplayString | read-only | Display Version |
| STR cps6000Ps1Verw | 1.3.6.1.4.1.10520.2.1.1.2.7 | DisplayString | read-only | Web Page Version |
| cps6000RchEntry | 1.3.6.1.4.1.10520.2.1.1.31.1 | not-accessible | Entry of information for one Ringer Chassis | |
| STR cps6000RchEntryDes | 1.3.6.1.4.1.10520.2.1.1.31.1.3 | DisplayString | read-write | Description |
| STR cps6000RchEntryIde | 1.3.6.1.4.1.10520.2.1.1.31.1.2 | DisplayString | read-only | Identifier |
| INT cps6000RchEntryIndex | 1.3.6.1.4.1.10520.2.1.1.31.1.1 | INTEGER | read-only | Table Index |
| STR cps6000RchEntryPri | 1.3.6.1.4.1.10520.2.1.1.31.1.6 | DisplayString | read-only | Primary Ringer |
| INT cps6000RchEntryRcdp | 1.3.6.1.4.1.10520.2.1.1.31.1.14 | INTEGER | read-only | Ringer ID Conflict Values: inactive(0), active(1) |
| INT cps6000RchEntryRf | 1.3.6.1.4.1.10520.2.1.1.31.1.8 | INTEGER | read-only | Ringer Minor Fail Values: inactive(0), active(1) |
| INT cps6000RchEntryRpff | 1.3.6.1.4.1.10520.2.1.1.31.1.9 | INTEGER | read-only | Ringer Fan Fail Values: inactive(0), active(1) |
| INT cps6000RchEntryRpfj | 1.3.6.1.4.1.10520.2.1.1.31.1.13 | INTEGER | read-only | Ringer Major Fail Values: inactive(0), active(1) |
| INT cps6000RchEntryRprl | 1.3.6.1.4.1.10520.2.1.1.31.1.12 | INTEGER | read-only | Ringer Redundency Loss Values: inactive(0), active(1) |
| INT cps6000RchEntryRpxj | 1.3.6.1.4.1.10520.2.1.1.31.1.10 | INTEGER | read-only | Ringer Major External Fault Values: inactive(0), active(1) |
| INT cps6000RchEntryRpxn | 1.3.6.1.4.1.10520.2.1.1.31.1.11 | INTEGER | read-only | Ringer Minor External Fault Values: inactive(0), active(1) |
| STR cps6000RchEntrySec | 1.3.6.1.4.1.10520.2.1.1.31.1.7 | DisplayString | read-only | Secondary Ringer |
| STR cps6000RchEntryStt | 1.3.6.1.4.1.10520.2.1.1.31.1.4 | DisplayString | read-write | Ringer Group State |
| I32 cps6000RchEntryVa | 1.3.6.1.4.1.10520.2.1.1.31.1.5 | Integer32 | read-only | Ringer Output VA |
| cps6000RchTable | 1.3.6.1.4.1.10520.2.1.1.31 | not-accessible | Table of all Ringer Chassis data | |
| cps6000RecEntry | 1.3.6.1.4.1.10520.2.1.1.6.1 | not-accessible | Entry of information for one Rectifier | |
| I32 cps6000RecEntryAac | 1.3.6.1.4.1.10520.2.1.1.6.1.20 | Integer32 | read-only | AC Current (mA) |
| STR cps6000RecEntryAcf | 1.3.6.1.4.1.10520.2.1.1.6.1.12 | DisplayString | read-only | AC Fail |
| STR cps6000RecEntryAdc | 1.3.6.1.4.1.10520.2.1.1.6.1.5 | DisplayString | read-only | DC Current (Amps) |
| STR cps6000RecEntryCap | 1.3.6.1.4.1.10520.2.1.1.6.1.8 | DisplayString | read-only | Capacity (Amps) |
| STR cps6000RecEntryClm | 1.3.6.1.4.1.10520.2.1.1.6.1.15 | DisplayString | read-only | Current Limit |
| STR cps6000RecEntryDes | 1.3.6.1.4.1.10520.2.1.1.6.1.3 | DisplayString | read-write | Description |
| STR cps6000RecEntryDid | 1.3.6.1.4.1.10520.2.1.1.6.1.14 | DisplayString | read-only | ID Conflict |
| STR cps6000RecEntryIde | 1.3.6.1.4.1.10520.2.1.1.6.1.2 | DisplayString | read-only | Identifier |
| INT cps6000RecEntryIndex | 1.3.6.1.4.1.10520.2.1.1.6.1.1 | INTEGER | read-only | Table Index |
| STR cps6000RecEntryMan | 1.3.6.1.4.1.10520.2.1.1.6.1.13 | DisplayString | read-only | Standby or Manual Off |
| STR cps6000RecEntryRcf | 1.3.6.1.4.1.10520.2.1.1.6.1.16 | DisplayString | read-only | Communication Failure |
| STR cps6000RecEntryRfa | 1.3.6.1.4.1.10520.2.1.1.6.1.11 | DisplayString | read-only | Rectifier Fail |
| STR cps6000RecEntryRfn | 1.3.6.1.4.1.10520.2.1.1.6.1.17 | DisplayString | read-only | Fan Failure |
| INT cps6000RecEntrySeq | 1.3.6.1.4.1.10520.2.1.1.6.1.10 | INTEGER | read-write | Use in Sequence Enable Values: no(0), yes(1) |
| STR cps6000RecEntrySn | 1.3.6.1.4.1.10520.2.1.1.6.1.18 | DisplayString | read-only | Serial Number |
| STR cps6000RecEntryStt | 1.3.6.1.4.1.10520.2.1.1.6.1.7 | DisplayString | read-write | State Values: ON, OFF, STANDBY, VACANT |
| STR cps6000RecEntryTmp | 1.3.6.1.4.1.10520.2.1.1.6.1.9 | DisplayString | read-only | Temperature (C) |
| STR cps6000RecEntryTyp | 1.3.6.1.4.1.10520.2.1.1.6.1.4 | DisplayString | read-write | Type |
| I32 cps6000RecEntryVac | 1.3.6.1.4.1.10520.2.1.1.6.1.19 | Integer32 | read-only | AC Voltage (Volts) |
| STR cps6000RecEntryVdc | 1.3.6.1.4.1.10520.2.1.1.6.1.6 | DisplayString | read-only | DC Voltage (Volts) |
| cps6000RecTable | 1.3.6.1.4.1.10520.2.1.1.6 | not-accessible | Table of all Rectifier data | |
| cps6000Retire | 1.3.6.1.4.1.10520.2.1.1.35 | |||
| NTF cps6000RetireAt1Ata | 1.3.6.1.4.1.10520.2.1.1.35.45 | Alarm Test Active | ||
| NTF cps6000RetireAt1Atb | 1.3.6.1.4.1.10520.2.1.1.35.46 | Alarm Test Aborted | ||
| NTF cps6000RetireBr1Bfa | 1.3.6.1.4.1.10520.2.1.1.35.53 | Battery Test Failed | ||
| NTF cps6000RetireBr1Bta | 1.3.6.1.4.1.10520.2.1.1.35.52 | Battery Test Active | ||
| NTF cps6000RetireBr1Btha | 1.3.6.1.4.1.10520.2.1.1.35.54 | High Battery Temperature | ||
| NTF cps6000RetireBr1Isda | 1.3.6.1.4.1.10520.2.1.1.35.55 | Imminent Shutdown | ||
| NTF cps6000RetireBr1Mdp | 1.3.6.1.4.1.10520.2.1.1.35.85 | Voltage Duplicate ID | ||
| NTF cps6000RetireBr1Mzd | 1.3.6.1.4.1.10520.2.1.1.35.86 | Voltage ID Not Configured | ||
| NTF cps6000RetireBr1Scda | 1.3.6.1.4.1.10520.2.1.1.35.87 | Shorted Cell Detected | ||
| NTF cps6000RetireBs1Bsa | 1.3.6.1.4.1.10520.2.1.1.35.51 | Boost State Alarm | ||
| NTF cps6000RetireCm1Cof | 1.3.6.1.4.1.10520.2.1.1.35.64 | Queue Overflow | ||
| NTF cps6000RetireCm1Cor | 1.3.6.1.4.1.10520.2.1.1.35.65 | Number Did Not Respond | ||
| NTF cps6000RetireCm1Nnc | 1.3.6.1.4.1.10520.2.1.1.35.66 | Number Not Configured | ||
| NTF cps6000RetireCn1Cnf | 1.3.6.1.4.1.10520.2.1.1.35.57 | Contactor Failed | ||
| NTF cps6000RetireCn1Cno | 1.3.6.1.4.1.10520.2.1.1.35.56 | Contactor Open | ||
| NTF cps6000RetireCn2Cnf | 1.3.6.1.4.1.10520.2.1.1.35.59 | Contactor Failed | ||
| NTF cps6000RetireCn2Cno | 1.3.6.1.4.1.10520.2.1.1.35.58 | Contactor Open | ||
| NTF cps6000RetireCn3Cnf | 1.3.6.1.4.1.10520.2.1.1.35.61 | Contactor Failed | ||
| NTF cps6000RetireCn3Cno | 1.3.6.1.4.1.10520.2.1.1.35.60 | Contactor Open | ||
| NTF cps6000RetireCn4Cnf | 1.3.6.1.4.1.10520.2.1.1.35.63 | Contactor Failed | ||
| NTF cps6000RetireCn4Cno | 1.3.6.1.4.1.10520.2.1.1.35.62 | Contactor Open | ||
| NTF cps6000RetireCp1Cfa | 1.3.6.1.4.1.10520.2.1.1.35.47 | Converter Fail | ||
| NTF cps6000RetireCp1Cfj | 1.3.6.1.4.1.10520.2.1.1.35.79 | Converter Fan Major | ||
| NTF cps6000RetireCp1Cfn | 1.3.6.1.4.1.10520.2.1.1.35.78 | Converter Fan Minor | ||
| NTF cps6000RetireCp1Dfa | 1.3.6.1.4.1.10520.2.1.1.35.48 | Distribution Fail | ||
| NTF cps6000RetireCp1Did | 1.3.6.1.4.1.10520.2.1.1.35.49 | ID Conflict | ||
| NTF cps6000RetireCp1Hfv | 1.3.6.1.4.1.10520.2.1.1.35.82 | Converter High Voltage Minor | ||
| NTF cps6000RetireCp1Hva | 1.3.6.1.4.1.10520.2.1.1.35.81 | Converter High Voltage Major | ||
| NTF cps6000RetireCp1Icc | 1.3.6.1.4.1.10520.2.1.1.35.80 | Incompatible Converter Alarm | ||
| NTF cps6000RetireCp1Mfa | 1.3.6.1.4.1.10520.2.1.1.35.50 | Multiple Converter Fail | ||
| NTF cps6000RetireCp1Rl | 1.3.6.1.4.1.10520.2.1.1.35.84 | Converter Redundancy Loss | ||
| NTF cps6000RetireCp1Vla | 1.3.6.1.4.1.10520.2.1.1.35.83 | Converter Very Low Voltage | ||
| NTF cps6000RetireDc1Acf | 1.3.6.1.4.1.10520.2.1.1.35.17 | AC Fail | ||
| NTF cps6000RetireDc1Amj | 1.3.6.1.4.1.10520.2.1.1.35.1 | Auxiliary Fuse Major | ||
| NTF cps6000RetireDc1Bda | 1.3.6.1.4.1.10520.2.1.1.35.24 | Battery On Discharge | ||
| NTF cps6000RetireDc1Clm | 1.3.6.1.4.1.10520.2.1.1.35.15 | Rectifier Current Limit | ||
| NTF cps6000RetireDc1Cma | 1.3.6.1.4.1.10520.2.1.1.35.10 | Minor Communication Failure | ||
| NTF cps6000RetireDc1Did | 1.3.6.1.4.1.10520.2.1.1.35.14 | ID Conflict | ||
| NTF cps6000RetireDc1Emd | 1.3.6.1.4.1.10520.2.1.1.35.77 | Energy Management Disabled | ||
| NTF cps6000RetireDc1Epo | 1.3.6.1.4.1.10520.2.1.1.35.2 | Emergency Power Off | ||
| NTF cps6000RetireDc1Faj | 1.3.6.1.4.1.10520.2.1.1.35.3 | External Fuse Major | ||
| NTF cps6000RetireDc1Fan | 1.3.6.1.4.1.10520.2.1.1.35.4 | External Fuse Minor | ||
| NTF cps6000RetireDc1Hfv | 1.3.6.1.4.1.10520.2.1.1.35.26 | High Float Voltage | ||
| NTF cps6000RetireDc1Hva | 1.3.6.1.4.1.10520.2.1.1.35.25 | High Voltage | ||
| NTF cps6000RetireDc1Icr | 1.3.6.1.4.1.10520.2.1.1.35.75 | Incompatible Rectifier | ||
| NTF cps6000RetireDc1Lsf | 1.3.6.1.4.1.10520.2.1.1.35.100 | Loadshare Fail | ||
| NTF cps6000RetireDc1Macf | 1.3.6.1.4.1.10520.2.1.1.35.11 | Multiple AC Failure | ||
| NTF cps6000RetireDc1Man | 1.3.6.1.4.1.10520.2.1.1.35.18 | Manual Off | ||
| NTF cps6000RetireDc1Mcm | 1.3.6.1.4.1.10520.2.1.1.35.12 | Major Communication Failure | ||
| NTF cps6000RetireDc1Mfa | 1.3.6.1.4.1.10520.2.1.1.35.20 | Multiple Rectifier Fail | ||
| NTF cps6000RetireDc1Mman | 1.3.6.1.4.1.10520.2.1.1.35.19 | Multiple Manual Off | ||
| NTF cps6000RetireDc1Osa | 1.3.6.1.4.1.10520.2.1.1.35.6 | Open String | ||
| NTF cps6000RetireDc1Rfa | 1.3.6.1.4.1.10520.2.1.1.35.13 | Rectifier Fail | ||
| NTF cps6000RetireDc1Rfn | 1.3.6.1.4.1.10520.2.1.1.35.76 | Rectifier Fan Fail | ||
| NTF cps6000RetireDc1Rls | 1.3.6.1.4.1.10520.2.1.1.35.23 | Redundancy Loss | ||
| NTF cps6000RetireDc1Rrtl | 1.3.6.1.4.1.10520.2.1.1.35.22 | Real-time Reserve Time Low | ||
| NTF cps6000RetireDc1Rtl | 1.3.6.1.4.1.10520.2.1.1.35.21 | Reserve Time Low | ||
| NTF cps6000RetireDc1Tpa | 1.3.6.1.4.1.10520.2.1.1.35.8 | Thermal Probe Alarm | ||
| NTF cps6000RetireDc1Vla | 1.3.6.1.4.1.10520.2.1.1.35.16 | Very Low Voltage | ||
| NTF cps6000RetireDc1Vmf | 1.3.6.1.4.1.10520.2.1.1.35.9 | Voltage Module Fail | ||
| NTF cps6000RetireDc1Vsf | 1.3.6.1.4.1.10520.2.1.1.35.5 | Sense/Control Fuse | ||
| NTF cps6000RetireDc1Zid | 1.3.6.1.4.1.10520.2.1.1.35.7 | ID Not Configured | ||
| NTF cps6000RetireFt1Cbt | 1.3.6.1.4.1.10520.2.1.1.35.93 | Circuit Breaker Trip | ||
| NTF cps6000RetireFt1Ctf | 1.3.6.1.4.1.10520.2.1.1.35.94 | Circuit Fail | ||
| NTF cps6000RetireFt1Fmi | 1.3.6.1.4.1.10520.2.1.1.35.89 | Fan Fail Minor | ||
| NTF cps6000RetireFt1Fmj | 1.3.6.1.4.1.10520.2.1.1.35.90 | Fan Fail Major | ||
| NTF cps6000RetireFt1Ipi | 1.3.6.1.4.1.10520.2.1.1.35.91 | Input Power Minor | ||
| NTF cps6000RetireFt1Ipj | 1.3.6.1.4.1.10520.2.1.1.35.92 | Input Power Major | ||
| NTF cps6000RetireFt1Lda | 1.3.6.1.4.1.10520.2.1.1.35.97 | Load Drop Alarm | ||
| NTF cps6000RetireFt1Lor | 1.3.6.1.4.1.10520.2.1.1.35.96 | Loss of Redundancy | ||
| NTF cps6000RetireFt1Lsa | 1.3.6.1.4.1.10520.2.1.1.35.98 | Load Share Alarm | ||
| NTF cps6000RetireFt1Lta | 1.3.6.1.4.1.10520.2.1.1.35.99 | Line Test Failed Alarm | ||
| NTF cps6000RetireFt1Mctf | 1.3.6.1.4.1.10520.2.1.1.35.95 | Multiple Circuit Fail | ||
| NTF cps6000RetirePo1Por | 1.3.6.1.4.1.10520.2.1.1.35.67 | Number Did Not Respond | ||
| NTF cps6000RetirePs1Amth | 1.3.6.1.4.1.10520.2.1.1.35.27 | High Ambient Temperature | ||
| NTF cps6000RetirePs1Amtl | 1.3.6.1.4.1.10520.2.1.1.35.28 | Low Ambient Temperature | ||
| NTF cps6000RetirePs1Ax1 | 1.3.6.1.4.1.10520.2.1.1.35.39 | Auxilliary Event 1 | ||
| NTF cps6000RetirePs1Ax2 | 1.3.6.1.4.1.10520.2.1.1.35.40 | Auxilliary Event 1 | ||
| NTF cps6000RetirePs1Ax3 | 1.3.6.1.4.1.10520.2.1.1.35.41 | Auxilliary Event 1 | ||
| NTF cps6000RetirePs1Ax4 | 1.3.6.1.4.1.10520.2.1.1.35.42 | Auxilliary Event 1 | ||
| NTF cps6000RetirePs1Ax5 | 1.3.6.1.4.1.10520.2.1.1.35.43 | Auxilliary Event 1 | ||
| NTF cps6000RetirePs1Ax6 | 1.3.6.1.4.1.10520.2.1.1.35.44 | Auxilliary Event 1 | ||
| NTF cps6000RetirePs1Bbl | 1.3.6.1.4.1.10520.2.1.1.35.29 | Memory Backup Battery Low | ||
| NTF cps6000RetirePs1Cch | 1.3.6.1.4.1.10520.2.1.1.35.30 | Configuration Changed | ||
| NTF cps6000RetirePs1Clc | 1.3.6.1.4.1.10520.2.1.1.35.31 | Clock Changed | ||
| NTF cps6000RetirePs1Epr | 1.3.6.1.4.1.10520.2.1.1.35.32 | External Password Reset | ||
| NTF cps6000RetirePs1Exl | 1.3.6.1.4.1.10520.2.1.1.35.33 | Excessive Login Attempts | ||
| NTF cps6000RetirePs1Hcl | 1.3.6.1.4.1.10520.2.1.1.35.34 | History Cleared | ||
| NTF cps6000RetirePs1Pfd | 1.3.6.1.4.1.10520.2.1.1.35.35 | Passwords At Default | ||
| NTF cps6000RetirePs1Pgi | 1.3.6.1.4.1.10520.2.1.1.35.38 | Program Line Invalid | ||
| NTF cps6000RetirePs1Pht | 1.3.6.1.4.1.10520.2.1.1.35.36 | Processor Halt | ||
| NTF cps6000RetirePs1Stf | 1.3.6.1.4.1.10520.2.1.1.35.37 | Self Test Failed | ||
| NTF cps6000RetireRp1Rcdp | 1.3.6.1.4.1.10520.2.1.1.35.88 | Ringer ID Conflict | ||
| NTF cps6000RetireRp1Rf | 1.3.6.1.4.1.10520.2.1.1.35.68 | Ringer Minor Fail | ||
| NTF cps6000RetireRp1Rpff | 1.3.6.1.4.1.10520.2.1.1.35.69 | Ringer Fan Fail | ||
| NTF cps6000RetireRp1Rpfj | 1.3.6.1.4.1.10520.2.1.1.35.73 | Ringer Major Fail | ||
| NTF cps6000RetireRp1Rprl | 1.3.6.1.4.1.10520.2.1.1.35.72 | Ringer Redundency Loss | ||
| NTF cps6000RetireRp1Rpxj | 1.3.6.1.4.1.10520.2.1.1.35.70 | Ringer Major External Fault | ||
| NTF cps6000RetireRp1Rpxn | 1.3.6.1.4.1.10520.2.1.1.35.71 | Ringer Minor External Fault | ||
| NTF cps6000RetireUserDefined | 1.3.6.1.4.1.10520.2.1.1.35.74 | This may be a user defined event, or a new controller event. | ||
| cps6000Rp1 | 1.3.6.1.4.1.10520.2.1.1.30 | |||
| STR cps6000Rp1Des | 1.3.6.1.4.1.10520.2.1.1.30.2 | DisplayString | read-write | Description |
| I32 cps6000Rp1Frq | 1.3.6.1.4.1.10520.2.1.1.30.3 | Integer32 | read-write | Frequency (Hz) |
| STR cps6000Rp1Ide | 1.3.6.1.4.1.10520.2.1.1.30.1 | DisplayString | read-only | Identifier |
| INT cps6000Rp1Ofe | 1.3.6.1.4.1.10520.2.1.1.30.5 | INTEGER | read-write | Offset Values: disable(0), enable(1) |
| STR cps6000Rp1Rcdp | 1.3.6.1.4.1.10520.2.1.1.30.14 | DisplayString | read-only | Ringer ID Conflict Value: Alarm report from RCDP1 |
| STR cps6000Rp1Rf | 1.3.6.1.4.1.10520.2.1.1.30.8 | DisplayString | read-only | Ringer Minor Fail |
| INT cps6000Rp1Rme | 1.3.6.1.4.1.10520.2.1.1.30.6 | INTEGER | read-write | Redundancy Monitor Values: disable(0), enable(1) |
| STR cps6000Rp1Rpff | 1.3.6.1.4.1.10520.2.1.1.30.9 | DisplayString | read-only | Ringer Fan Fail |
| STR cps6000Rp1Rpfj | 1.3.6.1.4.1.10520.2.1.1.30.13 | DisplayString | read-only | Ringer Major Fail |
| STR cps6000Rp1Rprl | 1.3.6.1.4.1.10520.2.1.1.30.12 | DisplayString | read-only | Ringer Redundency Loss |
| STR cps6000Rp1Rpxj | 1.3.6.1.4.1.10520.2.1.1.30.10 | DisplayString | read-only | Ringer Major External Fault |
| STR cps6000Rp1Rpxn | 1.3.6.1.4.1.10520.2.1.1.30.11 | DisplayString | read-only | Ringer Minor External Fault |
| INT cps6000Rp1Rss | 1.3.6.1.4.1.10520.2.1.1.30.7 | INTEGER | read-write | Restart Values: restart(1) |
| I32 cps6000Rp1Vsp | 1.3.6.1.4.1.10520.2.1.1.30.4 | Integer32 | read-write | Voltage Set-point (Volts) |
| cps6000Sc1 | 1.3.6.1.4.1.10520.2.1.1.10 | |||
| STR cps6000Sc1Des | 1.3.6.1.4.1.10520.2.1.1.10.2 | DisplayString | read-write | Description |
| STR cps6000Sc1Ide | 1.3.6.1.4.1.10520.2.1.1.10.1 | DisplayString | read-only | Identifier |
| I32 cps6000Sc1Lsp | 1.3.6.1.4.1.10520.2.1.1.10.9 | Integer32 | read-write | Lower Temperature Slope/Cell (mV/C/Cell) |
| I32 cps6000Sc1Ltt | 1.3.6.1.4.1.10520.2.1.1.10.5 | Integer32 | read-write | Lower Temperature Threshold (C) |
| I32 cps6000Sc1Ntt | 1.3.6.1.4.1.10520.2.1.1.10.6 | Integer32 | read-write | Nominal Temperature Threshold (C) |
| INT cps6000Sc1Rve | 1.3.6.1.4.1.10520.2.1.1.10.4 | INTEGER | read-write | Raise Voltage Enable Values: disable(0), enable(1) |
| I32 cps6000Sc1Spt | 1.3.6.1.4.1.10520.2.1.1.10.8 | Integer32 | read-write | Step Temperature (C) |
| INT cps6000Sc1Stt | 1.3.6.1.4.1.10520.2.1.1.10.3 | INTEGER | read-write | State Values: disable(0), enable(1) |
| I32 cps6000Sc1Usp | 1.3.6.1.4.1.10520.2.1.1.10.10 | Integer32 | read-write | Upper Temperature Slope/Cell (mV/C/Cell) |
| I32 cps6000Sc1Utt | 1.3.6.1.4.1.10520.2.1.1.10.7 | Integer32 | read-write | Upper Temperature Threshold (C) |
| cps6000ShfEntry | 1.3.6.1.4.1.10520.2.1.1.39.1 | not-accessible | Entry of information for one Converter Shelf | |
| INT cps6000ShfEntryCba | 1.3.6.1.4.1.10520.2.1.1.39.1.12 | INTEGER | read-only | Circuit Breaker A Trip Values: inactive(0), active(1) |
| INT cps6000ShfEntryCbb | 1.3.6.1.4.1.10520.2.1.1.39.1.13 | INTEGER | read-only | Circuit Breaker B Trip Values: inactive(0), active(1) |
| INT cps6000ShfEntryCvi | 1.3.6.1.4.1.10520.2.1.1.39.1.15 | INTEGER | read-only | Converter Minor Values: inactive(0), active(1) |
| INT cps6000ShfEntryCvj | 1.3.6.1.4.1.10520.2.1.1.39.1.14 | INTEGER | read-only | Converter Major Values: inactive(0), active(1) |
| STR cps6000ShfEntryDes | 1.3.6.1.4.1.10520.2.1.1.39.1.3 | DisplayString | read-only | Description |
| INT cps6000ShfEntryIa1 | 1.3.6.1.4.1.10520.2.1.1.39.1.6 | INTEGER | read-only | Input Voltage A1 Fail Values: inactive(0), active(1) |
| INT cps6000ShfEntryIa2 | 1.3.6.1.4.1.10520.2.1.1.39.1.7 | INTEGER | read-only | Input Voltage A2 Fail Values: inactive(0), active(1) |
| STR cps6000ShfEntryIadc | 1.3.6.1.4.1.10520.2.1.1.39.1.5 | DisplayString | read-only | Input Current (Amps) |
| INT cps6000ShfEntryIb1 | 1.3.6.1.4.1.10520.2.1.1.39.1.8 | INTEGER | read-only | Input Voltage B1 Fail Values: inactive(0), active(1) |
| INT cps6000ShfEntryIb2 | 1.3.6.1.4.1.10520.2.1.1.39.1.9 | INTEGER | read-only | Input Voltage B2 Fail Values: inactive(0), active(1) |
| STR cps6000ShfEntryIde | 1.3.6.1.4.1.10520.2.1.1.39.1.2 | DisplayString | read-only | Identifier |
| INT cps6000ShfEntryIndex | 1.3.6.1.4.1.10520.2.1.1.39.1.1 | INTEGER | read-only | Table Index |
| INT cps6000ShfEntryLfn | 1.3.6.1.4.1.10520.2.1.1.39.1.11 | INTEGER | read-only | Lower Fan Fail Values: inactive(0), active(1) |
| I32 cps6000ShfEntryNoc | 1.3.6.1.4.1.10520.2.1.1.39.1.16 | Integer32 | read-only | Number of Converters in Shelf |
| STR cps6000ShfEntryStt | 1.3.6.1.4.1.10520.2.1.1.39.1.4 | DisplayString | read-only | State Values: PRESENT, MISSING |
| INT cps6000ShfEntryUfn | 1.3.6.1.4.1.10520.2.1.1.39.1.10 | INTEGER | read-only | Upper Fan Fail Values: inactive(0), active(1) |
| cps6000ShfTable | 1.3.6.1.4.1.10520.2.1.1.39 | not-accessible | Table of all Converter Shelf data | |
| cps6000SndEntry | 1.3.6.1.4.1.10520.2.1.1.20.1 | not-accessible | Entry of information for one SNMP Trap Destination | |
| STR cps6000SndEntryCs | 1.3.6.1.4.1.10520.2.1.1.20.1.5 | DisplayString | read-write | Community String |
| STR cps6000SndEntryDes | 1.3.6.1.4.1.10520.2.1.1.20.1.3 | DisplayString | read-write | Description |
| STR cps6000SndEntryIde | 1.3.6.1.4.1.10520.2.1.1.20.1.2 | DisplayString | read-only | Identifier |
| INT cps6000SndEntryIndex | 1.3.6.1.4.1.10520.2.1.1.20.1.1 | INTEGER | read-only | Table Index |
| STR cps6000SndEntryIp | 1.3.6.1.4.1.10520.2.1.1.20.1.4 | DisplayString | read-write | IP Address |
| cps6000SndTable | 1.3.6.1.4.1.10520.2.1.1.20 | not-accessible | Table of all SNMP Trap Destination data | |
| cps6000Tl1Entry | 1.3.6.1.4.1.10520.2.1.1.26.1 | not-accessible | Entry of information for one TL1 Object | |
| STR cps6000Tl1EntryAid | 1.3.6.1.4.1.10520.2.1.1.26.1.5 | DisplayString | read-write | Aid |
| STR cps6000Tl1EntryCds | 1.3.6.1.4.1.10520.2.1.1.26.1.4 | DisplayString | read-write | Condition Description |
| STR cps6000Tl1EntryCnd | 1.3.6.1.4.1.10520.2.1.1.26.1.6 | DisplayString | read-write | Condition Type |
| STR cps6000Tl1EntryDes | 1.3.6.1.4.1.10520.2.1.1.26.1.3 | DisplayString | read-write | Description |
| STR cps6000Tl1EntryIde | 1.3.6.1.4.1.10520.2.1.1.26.1.2 | DisplayString | read-only | Identifier |
| INT cps6000Tl1EntryIndex | 1.3.6.1.4.1.10520.2.1.1.26.1.1 | INTEGER | read-only | Table Index |
| STR cps6000Tl1EntryRpt | 1.3.6.1.4.1.10520.2.1.1.26.1.8 | DisplayString | read-write | Reporting Values: EQUIPMENT, ENVIRONMENT, PRESENCE |
| INT cps6000Tl1EntrySaf | 1.3.6.1.4.1.10520.2.1.1.26.1.7 | INTEGER | read-write | Service Affecting Values: no(0), yes(1) |
| cps6000Tl1Table | 1.3.6.1.4.1.10520.2.1.1.26 | not-accessible | Table of all TL1 Object data | |
| cps6000Tlm1 | 1.3.6.1.4.1.10520.2.1.1.25 | |||
| INT cps6000Tlm1Aue | 1.3.6.1.4.1.10520.2.1.1.25.3 | INTEGER | read-write | Activate-User Enable Values: disable(0), enable(1) |
| INT cps6000Tlm1Cts | 1.3.6.1.4.1.10520.2.1.1.25.4 | INTEGER | read-write | CTS Connect Detection Values: disable(0), enable(1) |
| STR cps6000Tlm1Des | 1.3.6.1.4.1.10520.2.1.1.25.2 | DisplayString | read-write | Description |
| INT cps6000Tlm1Dsr | 1.3.6.1.4.1.10520.2.1.1.25.5 | INTEGER | read-write | DSR Connect Detection Values: disable(0), enable(1) |
| STR cps6000Tlm1Ide | 1.3.6.1.4.1.10520.2.1.1.25.1 | DisplayString | read-only | Identifier |
| I32 cps6000Tlm1Prt | 1.3.6.1.4.1.10520.2.1.1.25.6 | Integer32 | read-write | TCP/IP Port |
| cps6000Trap | 1.3.6.1.4.1.10520.2.1.1.33 | |||
| NTF cps6000TrapAt1Ata | 1.3.6.1.4.1.10520.2.1.1.33.45 | Alarm Test Active | ||
| NTF cps6000TrapAt1Atb | 1.3.6.1.4.1.10520.2.1.1.33.46 | Alarm Test Aborted | ||
| NTF cps6000TrapBr1Bfa | 1.3.6.1.4.1.10520.2.1.1.33.53 | Battery Test Failed | ||
| NTF cps6000TrapBr1Bta | 1.3.6.1.4.1.10520.2.1.1.33.52 | Battery Test Active | ||
| NTF cps6000TrapBr1Btha | 1.3.6.1.4.1.10520.2.1.1.33.54 | High Battery Temperature | ||
| NTF cps6000TrapBr1Isda | 1.3.6.1.4.1.10520.2.1.1.33.55 | Imminent Shutdown | ||
| NTF cps6000TrapBr1Mdp | 1.3.6.1.4.1.10520.2.1.1.33.85 | Voltage Duplicate ID | ||
| NTF cps6000TrapBr1Mzd | 1.3.6.1.4.1.10520.2.1.1.33.86 | Voltage ID Not Configured | ||
| NTF cps6000TrapBr1Scda | 1.3.6.1.4.1.10520.2.1.1.33.87 | Shorted Cell Detected | ||
| NTF cps6000TrapBs1Bsa | 1.3.6.1.4.1.10520.2.1.1.33.51 | Boost State Alarm | ||
| NTF cps6000TrapCm1Cof | 1.3.6.1.4.1.10520.2.1.1.33.64 | Queue Overflow | ||
| NTF cps6000TrapCm1Cor | 1.3.6.1.4.1.10520.2.1.1.33.65 | Number Did Not Respond | ||
| NTF cps6000TrapCm1Nnc | 1.3.6.1.4.1.10520.2.1.1.33.66 | Number Not Configured | ||
| NTF cps6000TrapCn1Cnf | 1.3.6.1.4.1.10520.2.1.1.33.57 | Contactor Failed | ||
| NTF cps6000TrapCn1Cno | 1.3.6.1.4.1.10520.2.1.1.33.56 | Contactor Open | ||
| NTF cps6000TrapCn2Cnf | 1.3.6.1.4.1.10520.2.1.1.33.59 | Contactor Failed | ||
| NTF cps6000TrapCn2Cno | 1.3.6.1.4.1.10520.2.1.1.33.58 | Contactor Open | ||
| NTF cps6000TrapCn3Cnf | 1.3.6.1.4.1.10520.2.1.1.33.61 | Contactor Failed | ||
| NTF cps6000TrapCn3Cno | 1.3.6.1.4.1.10520.2.1.1.33.60 | Contactor Open | ||
| NTF cps6000TrapCn4Cnf | 1.3.6.1.4.1.10520.2.1.1.33.63 | Contactor Failed | ||
| NTF cps6000TrapCn4Cno | 1.3.6.1.4.1.10520.2.1.1.33.62 | Contactor Open | ||
| NTF cps6000TrapCp1Cfa | 1.3.6.1.4.1.10520.2.1.1.33.47 | Converter Fail | ||
| NTF cps6000TrapCp1Cfj | 1.3.6.1.4.1.10520.2.1.1.33.79 | Converter Fan Major | ||
| NTF cps6000TrapCp1Cfn | 1.3.6.1.4.1.10520.2.1.1.33.78 | Converter Fan Minor | ||
| NTF cps6000TrapCp1Dfa | 1.3.6.1.4.1.10520.2.1.1.33.48 | Distribution Fail | ||
| NTF cps6000TrapCp1Did | 1.3.6.1.4.1.10520.2.1.1.33.49 | ID Conflict | ||
| NTF cps6000TrapCp1Hfv | 1.3.6.1.4.1.10520.2.1.1.33.82 | Converter High Voltage Minor | ||
| NTF cps6000TrapCp1Hva | 1.3.6.1.4.1.10520.2.1.1.33.81 | Converter High Voltage Major | ||
| NTF cps6000TrapCp1Icc | 1.3.6.1.4.1.10520.2.1.1.33.80 | Incompatible Converter Alarm | ||
| NTF cps6000TrapCp1Mfa | 1.3.6.1.4.1.10520.2.1.1.33.50 | Multiple Converter Fail | ||
| NTF cps6000TrapCp1Rl | 1.3.6.1.4.1.10520.2.1.1.33.84 | Converter Redundancy Loss | ||
| NTF cps6000TrapCp1Vla | 1.3.6.1.4.1.10520.2.1.1.33.83 | Converter Very Low Voltage | ||
| NTF cps6000TrapDc1Acf | 1.3.6.1.4.1.10520.2.1.1.33.17 | AC Fail | ||
| NTF cps6000TrapDc1Amj | 1.3.6.1.4.1.10520.2.1.1.33.1 | Auxiliary Fuse Major | ||
| NTF cps6000TrapDc1Bda | 1.3.6.1.4.1.10520.2.1.1.33.24 | Battery On Discharge | ||
| NTF cps6000TrapDc1Clm | 1.3.6.1.4.1.10520.2.1.1.33.15 | Rectifier Current Limit | ||
| NTF cps6000TrapDc1Cma | 1.3.6.1.4.1.10520.2.1.1.33.10 | Minor Communication Failure | ||
| NTF cps6000TrapDc1Did | 1.3.6.1.4.1.10520.2.1.1.33.14 | ID Conflict | ||
| NTF cps6000TrapDc1Emd | 1.3.6.1.4.1.10520.2.1.1.33.77 | Energy Management Disabled | ||
| NTF cps6000TrapDc1Epo | 1.3.6.1.4.1.10520.2.1.1.33.2 | Emergency Power Off | ||
| NTF cps6000TrapDc1Faj | 1.3.6.1.4.1.10520.2.1.1.33.3 | External Fuse Major | ||
| NTF cps6000TrapDc1Fan | 1.3.6.1.4.1.10520.2.1.1.33.4 | External Fuse Minor | ||
| NTF cps6000TrapDc1Hfv | 1.3.6.1.4.1.10520.2.1.1.33.26 | High Float Voltage | ||
| NTF cps6000TrapDc1Hva | 1.3.6.1.4.1.10520.2.1.1.33.25 | High Voltage | ||
| NTF cps6000TrapDc1Icr | 1.3.6.1.4.1.10520.2.1.1.33.75 | Incompatible Rectifier | ||
| NTF cps6000TrapDc1Lsf | 1.3.6.1.4.1.10520.2.1.1.33.100 | Loadshare Fail | ||
| NTF cps6000TrapDc1Macf | 1.3.6.1.4.1.10520.2.1.1.33.11 | Multiple AC Failure | ||
| NTF cps6000TrapDc1Man | 1.3.6.1.4.1.10520.2.1.1.33.18 | Manual Off | ||
| NTF cps6000TrapDc1Mcm | 1.3.6.1.4.1.10520.2.1.1.33.12 | Major Communication Failure | ||
| NTF cps6000TrapDc1Mfa | 1.3.6.1.4.1.10520.2.1.1.33.20 | Multiple Rectifier Fail | ||
| NTF cps6000TrapDc1Mman | 1.3.6.1.4.1.10520.2.1.1.33.19 | Multiple Manual Off | ||
| NTF cps6000TrapDc1Osa | 1.3.6.1.4.1.10520.2.1.1.33.6 | Open String | ||
| NTF cps6000TrapDc1Rfa | 1.3.6.1.4.1.10520.2.1.1.33.13 | Rectifier Fail | ||
| NTF cps6000TrapDc1Rfn | 1.3.6.1.4.1.10520.2.1.1.33.76 | Rectifier Fan Fail | ||
| NTF cps6000TrapDc1Rls | 1.3.6.1.4.1.10520.2.1.1.33.23 | Redundancy Loss | ||
| NTF cps6000TrapDc1Rrtl | 1.3.6.1.4.1.10520.2.1.1.33.22 | Real-time Reserve Time Low | ||
| NTF cps6000TrapDc1Rtl | 1.3.6.1.4.1.10520.2.1.1.33.21 | Reserve Time Low | ||
| NTF cps6000TrapDc1Tpa | 1.3.6.1.4.1.10520.2.1.1.33.8 | Thermal Probe Alarm | ||
| NTF cps6000TrapDc1Vla | 1.3.6.1.4.1.10520.2.1.1.33.16 | Very Low Voltage | ||
| NTF cps6000TrapDc1Vmf | 1.3.6.1.4.1.10520.2.1.1.33.9 | Voltage Module Fail | ||
| NTF cps6000TrapDc1Vsf | 1.3.6.1.4.1.10520.2.1.1.33.5 | Sense/Control Fuse | ||
| NTF cps6000TrapDc1Zid | 1.3.6.1.4.1.10520.2.1.1.33.7 | ID Not Configured | ||
| NTF cps6000TrapFt1Cbt | 1.3.6.1.4.1.10520.2.1.1.33.93 | Circuit Breaker Trip | ||
| NTF cps6000TrapFt1Ctf | 1.3.6.1.4.1.10520.2.1.1.33.94 | Circuit Fail | ||
| NTF cps6000TrapFt1Fmi | 1.3.6.1.4.1.10520.2.1.1.33.89 | Fan Fail Minor | ||
| NTF cps6000TrapFt1Fmj | 1.3.6.1.4.1.10520.2.1.1.33.90 | Fan Fail Major | ||
| NTF cps6000TrapFt1Ipi | 1.3.6.1.4.1.10520.2.1.1.33.91 | Input Power Minor | ||
| NTF cps6000TrapFt1Ipj | 1.3.6.1.4.1.10520.2.1.1.33.92 | Input Power Major | ||
| NTF cps6000TrapFt1Lda | 1.3.6.1.4.1.10520.2.1.1.33.97 | Load Drop Alarm | ||
| NTF cps6000TrapFt1Lor | 1.3.6.1.4.1.10520.2.1.1.33.96 | Loss of Redundancy | ||
| NTF cps6000TrapFt1Lsa | 1.3.6.1.4.1.10520.2.1.1.33.98 | Load Share Alarm | ||
| NTF cps6000TrapFt1Lta | 1.3.6.1.4.1.10520.2.1.1.33.99 | Line Test Failed Alarm | ||
| NTF cps6000TrapFt1Mctf | 1.3.6.1.4.1.10520.2.1.1.33.95 | Multiple Circuit Fail | ||
| NTF cps6000TrapPo1Por | 1.3.6.1.4.1.10520.2.1.1.33.67 | Number Did Not Respond | ||
| NTF cps6000TrapPs1Amth | 1.3.6.1.4.1.10520.2.1.1.33.27 | High Ambient Temperature | ||
| NTF cps6000TrapPs1Amtl | 1.3.6.1.4.1.10520.2.1.1.33.28 | Low Ambient Temperature | ||
| NTF cps6000TrapPs1Ax1 | 1.3.6.1.4.1.10520.2.1.1.33.39 | Auxilliary Event 1 | ||
| NTF cps6000TrapPs1Ax2 | 1.3.6.1.4.1.10520.2.1.1.33.40 | Auxilliary Event 1 | ||
| NTF cps6000TrapPs1Ax3 | 1.3.6.1.4.1.10520.2.1.1.33.41 | Auxilliary Event 1 | ||
| NTF cps6000TrapPs1Ax4 | 1.3.6.1.4.1.10520.2.1.1.33.42 | Auxilliary Event 1 | ||
| NTF cps6000TrapPs1Ax5 | 1.3.6.1.4.1.10520.2.1.1.33.43 | Auxilliary Event 1 | ||
| NTF cps6000TrapPs1Ax6 | 1.3.6.1.4.1.10520.2.1.1.33.44 | Auxilliary Event 1 | ||
| NTF cps6000TrapPs1Bbl | 1.3.6.1.4.1.10520.2.1.1.33.29 | Memory Backup Battery Low | ||
| NTF cps6000TrapPs1Cch | 1.3.6.1.4.1.10520.2.1.1.33.30 | Configuration Changed | ||
| NTF cps6000TrapPs1Clc | 1.3.6.1.4.1.10520.2.1.1.33.31 | Clock Changed | ||
| NTF cps6000TrapPs1Epr | 1.3.6.1.4.1.10520.2.1.1.33.32 | External Password Reset | ||
| NTF cps6000TrapPs1Exl | 1.3.6.1.4.1.10520.2.1.1.33.33 | Excessive Login Attempts | ||
| NTF cps6000TrapPs1Hcl | 1.3.6.1.4.1.10520.2.1.1.33.34 | History Cleared | ||
| NTF cps6000TrapPs1Pfd | 1.3.6.1.4.1.10520.2.1.1.33.35 | Passwords At Default | ||
| NTF cps6000TrapPs1Pgi | 1.3.6.1.4.1.10520.2.1.1.33.38 | Program Line Invalid | ||
| NTF cps6000TrapPs1Pht | 1.3.6.1.4.1.10520.2.1.1.33.36 | Processor Halt | ||
| NTF cps6000TrapPs1Stf | 1.3.6.1.4.1.10520.2.1.1.33.37 | Self Test Failed | ||
| NTF cps6000TrapRp1Rcdp | 1.3.6.1.4.1.10520.2.1.1.33.88 | Ringer ID Conflict | ||
| NTF cps6000TrapRp1Rf | 1.3.6.1.4.1.10520.2.1.1.33.68 | Ringer Minor Fail | ||
| NTF cps6000TrapRp1Rpff | 1.3.6.1.4.1.10520.2.1.1.33.69 | Ringer Fan Fail | ||
| NTF cps6000TrapRp1Rpfj | 1.3.6.1.4.1.10520.2.1.1.33.73 | Ringer Major Fail | ||
| NTF cps6000TrapRp1Rprl | 1.3.6.1.4.1.10520.2.1.1.33.72 | Ringer Redundency Loss | ||
| NTF cps6000TrapRp1Rpxj | 1.3.6.1.4.1.10520.2.1.1.33.70 | Ringer Major External Fault | ||
| NTF cps6000TrapRp1Rpxn | 1.3.6.1.4.1.10520.2.1.1.33.71 | Ringer Minor External Fault | ||
| NTF cps6000TrapUserDefined | 1.3.6.1.4.1.10520.2.1.1.33.74 | This may be a user defined event, or a new controller event. | ||
| cps6000UdeEntry | 1.3.6.1.4.1.10520.2.1.1.16.1 | not-accessible | Entry of information for one User Defined Event | |
| STR cps6000UdeEntryAcc | 1.3.6.1.4.1.10520.2.1.1.16.1.9 | DisplayString | read-write | Contact Closure Values: R1, R2, R3, R4 |
| STR cps6000UdeEntryAst | 1.3.6.1.4.1.10520.2.1.1.16.1.4 | DisplayString | read-only | Alarm State |
| STR cps6000UdeEntryDes | 1.3.6.1.4.1.10520.2.1.1.16.1.3 | DisplayString | read-write | Description |
| I32 cps6000UdeEntryDly | 1.3.6.1.4.1.10520.2.1.1.16.1.10 | Integer32 | read-write | Notify Delay (Seconds) |
| STR cps6000UdeEntryDst | 1.3.6.1.4.1.10520.2.1.1.16.1.14 | DisplayString | read-write | Notify Destination Values: P1, P2, P3, P4 |
| STR cps6000UdeEntryDur | 1.3.6.1.4.1.10520.2.1.1.16.1.7 | DisplayString | read-write | Minimum Duration (Seconds) |
| STR cps6000UdeEntryFds | 1.3.6.1.4.1.10520.2.1.1.16.1.15 | DisplayString | read-write | Front Panel Description |
| STR cps6000UdeEntryIde | 1.3.6.1.4.1.10520.2.1.1.16.1.2 | DisplayString | read-only | Identifier |
| INT cps6000UdeEntryIndex | 1.3.6.1.4.1.10520.2.1.1.16.1.1 | INTEGER | read-only | Table Index |
| INT cps6000UdeEntryLat | 1.3.6.1.4.1.10520.2.1.1.16.1.8 | INTEGER | read-write | Latched Values: no(0), yes(1) |
| INT cps6000UdeEntryNag | 1.3.6.1.4.1.10520.2.1.1.16.1.13 | INTEGER | read-write | NAG on Occur Values: no(0), yes(1) |
| INT cps6000UdeEntryNoo | 1.3.6.1.4.1.10520.2.1.1.16.1.11 | INTEGER | read-write | Notify on Occur Values: no(0), yes(1) |
| INT cps6000UdeEntryNor | 1.3.6.1.4.1.10520.2.1.1.16.1.12 | INTEGER | read-write | Notify on Retire Values: no(0), yes(1) |
| STR cps6000UdeEntryPrg | 1.3.6.1.4.1.10520.2.1.1.16.1.6 | DisplayString | read-write | Program Line |
| STR cps6000UdeEntrySev | 1.3.6.1.4.1.10520.2.1.1.16.1.5 | DisplayString | read-write | Severity Values: CRIT, MAJ, MIN, WRN, RO |
| cps6000UdeTable | 1.3.6.1.4.1.10520.2.1.1.16 | not-accessible | Table of all User Defined Event data | |
| prototypes | 1.3.6.1.4.1.10520.2.2 | |||
| release | 1.3.6.1.4.1.10520.2.1 | |||
| teps | 1.3.6.1.4.1.10520 | |||
| STR trapInfo | 1.3.6.1.4.1.10520.2.1.1.34 | DisplayString | accessible-for-notify | Supplemental alarm information |
RFC description
Manages Lineage Power CPS6000 distributed DC power system components and status.
Start monitoring CyberPower CPS6000-series UPS with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.