CPS6000-MIB

MIB Reference — IPNetwork Monitor · Updated September 09, 2026

All MIBsCPS6000-MIB

Organization: Lineage Power

Last Updated: 2009-06-18

Category: Hardware and Environment

Description: Manages CyberPower 6000-series UPS units providing power quality metrics, battery health, and alarm notifications.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is CPS6000-MIB?

CPS6000-MIB is a CyberPower Systems MIB for the CPS6000-series UPS/power protection product line, sitting under CyberPower's private enterprise "controllermibs" branch. It exposes DC power-subsystem objects for one or more DC/battery circuits (cps6000Dc1Ide, cps6000Dc1Des, cps6000Dc1Typ, cps6000Dc1Stt, cps6000Dc1Vdc, cps6000Dc1Adc, cps6000Dc1Cap, cps6000Dc1Olcap, cps6000Dc1Scap, cps6000Dc1Bty), covering identifiers, descriptions, hardware type, operational status, DC voltage/current, and capacity metrics. Its principal monitoring use is hardware health of the UPS's power system - battery status, DC voltage/current, and available/online/spare capacity - which together reveal battery aging, load conditions, and impending power problems before an outage causes a shutdown. As a self-contained vendor MIB it does not explicitly reference other IETF MIBs, though it parallels the general intent of the standard UPS-MIB. It is deployed wherever CyberPower CPS6000-series UPS units protect data-center or server-room equipment and are monitored over SNMP. Engineers can download the CPS6000-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in CPS6000-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • CyberPower CPS6000-series UPS

Monitoring Examples

An admin would poll cps6000Dc1Stt (DC circuit status) together with cps6000Dc1Vdc and cps6000Dc1Adc (DC voltage/current) to confirm a battery string is online and delivering expected power under load. A drop in cps6000Dc1Cap or cps6000Dc1Scap (capacity/spare capacity) alongside a degraded cps6000Dc1Stt would indicate an aging or failing battery needing replacement before it can no longer ride through a utility outage. cps6000Dc1Ide and cps6000Dc1Des provide the identifying label and description for the specific DC circuit being reported.

What Can Be Monitored

  • DC circuit status
  • DC voltage
  • DC current
  • battery capacity
  • online/spare capacity
  • battery health
Imported Objects

From SNMPv2-SMI

Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
enterprises

From SNMPv2-TC

DisplayString

How to Use in IPNetwork Monitor

Example using cps6000Dc1Vdc OID:

Select a CyberPower CPS6000-series UPS as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cps6000Dc1Vdc into the Find box to locate it in the OID tree, then select it and click OK. It reports the voltage (mV). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the reading drifts outside the range expected for healthy operation (in mV), since an unexpected voltage swing often points to a power-supply or wiring issue. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Manages Lineage Power CPS6000 distributed DC power system components and status.

Start monitoring CyberPower CPS6000-series UPS with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download CPS6000-MIB