ASETEK-RACKCDU-SMI-V1-MIB-V16

MIB Reference — IPNetwork Monitor · Updated September 09, 2026

All MIBsASETEK-RACKCDU-SMI-V1-MIB-V16

Category: Hardware and Environment

Description: Manages Asetek RackCDU liquid cooling distribution unit flow, temperature, and pump status.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is ASETEK-RACKCDU-SMI-V1-MIB-V16?

ASETEK-RACKCDU-SMI-V1-MIB-V16 is a vendor-specific SNMP MIB for Asetek's RackCDU rack-mounted coolant distribution units, used in direct-to-chip liquid cooling systems for high-density data center racks. It exposes data on the cooling loop such as coolant flow rate, supply/return temperature, pump operating state, and alarm conditions, alongside basic unit configuration. The MIB's central purpose is hardware status monitoring: tracking pump health, temperature readings, flow rate, and unit uptime so operators can detect a stalled pump or falling flow before it triggers a thermal shutdown of attached compute hardware. As a self-contained enterprise MIB under Asetek's private SMI branch, it has no apparent dependency on other standard MIBs. It is deployed in data centers using rack-level or row-based liquid cooling architectures serving high-density server racks, where CDU failure directly threatens compute uptime.

IPNetwork Monitor allows you to monitor SNMP objects defined in ASETEK-RACKCDU-SMI-V1-MIB-V16. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Asetek RackCDU liquid cooling distribution unit
  • data center high-density rack cooling hardware

Monitoring Examples

No object or table names were supplied for this module in the input data, so specific identifiers cannot be confirmed. Based on its description, a RackCDU MIB of this kind would typically expose objects for coolant flow rate, supply/return temperature, and pump/fault status. An administrator would poll these periodically to detect a deviation such as a drop in flow rate or a stalled pump, which precedes a thermal event in the racks it cools, and administrators can download the ASETEK-RACKCDU-SMI-V1-MIB-V16 file directly to load it into their MIB browser.

What Can Be Monitored

  • coolant flow rate
  • supply/return temperature
  • pump operating status
  • cooling loop alarm/fault state
  • unit uptime
Imported Objects

From RFC-1212

OBJECT-TYPE

From RFC-1215

TRAP-TYPE

From RFC1155-SMI

Gauge
IpAddress
enterprises

From RFC1213-MIB

DisplayString
sysContact
sysDescr
sysLocation
sysName
sysObjectID
sysServices
sysUpTime
OIDs

RFC description

Manages Asetek RackCDU cooling distribution units including temperature, pressure, and flow monitoring.

Start monitoring Asetek RackCDU liquid cooling distribution units with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download ASETEK-RACKCDU-SMI-V1-MIB-V16