All MIBs › LIEBERT-GP-CONTROLLER-MIB
Organization: Liebert Corporation
Last Updated: 2008-07-02
Category: Domain: Power Management, Domain: Power/UPS, Hardware and Environment
Description: Liebert Corporation MIB for managing Liebert data center infrastructure controller parameters and operational settings.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is LIEBERT-GP-CONTROLLER-MIB?
LIEBERT-GP-CONTROLLER-MIB is a Liebert Corporation (now Vertiv) enterprise MIB for a general-purpose data center infrastructure controller, used to manage precision cooling, power, or environmental control units. It exposes hardware status counts for control modules, such as how many are installed, failed, redundant, or reporting warnings, along with lower-level hardware telemetry like control board battery voltage. Its monitoring focus is squarely hardware health: an operator can track lgpCtrlNumberFailedControlModules to detect module failures, lgpCtrlNumberRedundantControlModules to confirm redundancy coverage is intact, lgpCtrlNumberControlModuleWarnings for early-warning conditions, and lgpCtrlBoardBatteryVoltage to catch a degrading backup battery before it causes a loss of control-board memory or settings during a power event. It is a self-contained Liebert enterprise MIB without a stated dependency on other standard MIBs. It is typically deployed on Liebert/Vertiv precision cooling and power infrastructure controllers in data centers and telecom equipment rooms where continuous environmental control is critical. Network engineers evaluating or troubleshooting this functionality can download the LIEBERT-GP-CONTROLLER-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in LIEBERT-GP-CONTROLLER-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Liebert/Vertiv data center precision cooling and power infrastructure controllers
Monitoring Examples
An operator would poll lgpCtrlNumberInstalledControlModules alongside lgpCtrlNumberFailedControlModules to compute how many control modules are currently down, and check lgpCtrlNumberRedundantControlModules to confirm N+1 redundancy is still available if a module fails. lgpCtrlBoardBatteryVoltage would be trended over time to catch a battery that is discharging or degrading, which could cause the controller to lose configuration during a power interruption, and a rise in lgpCtrlNumberControlModuleWarnings would flag modules trending toward failure before they actually fail.
What Can Be Monitored
- installed control module count
- failed control module count
- redundant control module count
- control module warning count
- control board battery voltage
Imported Objects
From LIEBERT-GP-REGISTRATION-MIB
| lgpController | OBJECT-IDENTITY |
| liebertControllerModuleReg | OBJECT-IDENTITY |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| OBJECT-TYPE | |
| Unsigned32 |
OIDs
RFC description
Specifies OIDs and manages control modules in Liebert power management and monitoring equipment.
Start monitoring Liebert/Vertiv precision cooling and power infrastructure controller with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.