| OID symbolic | OID numeric | Type | Access | Description |
| equipmentCommonObjects | 1.3.6.1.4.1.7262.20.1 | | | |
| equipmentConfigLog | 1.3.6.1.4.1.7262.20.1.1 | | | |
| U32 equipmentEventLogEntryLimit | 1.3.6.1.4.1.7262.20.1.1.1 | Unsigned32 | read-only | The maximum number of notification entries that may be held
in EventLogTable. |
| equipmentLog | 1.3.6.1.4.1.7262.20.1.2 | | | |
| U32 equipmentEventLogLastEntry | 1.3.6.1.4.1.7262.20.1.2.1 | Unsigned32 | read-only | The value of equipmentEventLogIndex at the time of the last
creation of an entry in the equipmentEventLogTable. |
| equipmentEventLogTable | 1.3.6.1.4.1.7262.20.1.2.2 | | not-accessible | A table of Notification log entries. |
| equipmentEventLogEntry | 1.3.6.1.4.1.7262.20.1.2.2.1 | | not-accessible | A Notification log entry. Entries appear in this table
when Notifications occur. They are removed to make way
for new entries due to lack of resources or the values of
equipmentEventLogEntryLimit.If adding an entry would exceed
equipmentEventLogEntryLimit the oldest entry in that log SHOULD
be removed to make room for the new one. |
| U32 equipmentEventLogIndex | 1.3.6.1.4.1.7262.20.1.2.2.1.1 | Unsigned32 | not-accessible | A monotonically increasing integer for the sole purpose of
indexing entries within the log. When it reaches the
maximum value,the agent wraps the value back to 1.
This number should correspond to the number of notifications
sent by the agent. |
| TIM equipmentEventLogTime | 1.3.6.1.4.1.7262.20.1.2.2.1.2 | TimeStamp | read-only | The value of sysUpTime when the entry was placed in the log. |
| DAT equipmentEventLogDateAndTime | 1.3.6.1.4.1.7262.20.1.2.2.1.3 | DateAndTime | read-only | The local date and time when the entry was logged, useful when browsing the MIB. |
| OID equipmentEventLogNotificationID | 1.3.6.1.4.1.7262.20.1.2.2.1.4 | OBJECT IDENTIFIER | read-only | The NOTIFICATION-TYPE object identifier of the Notification that
occurred. |
| U32 equipmentEventLogVariables | 1.3.6.1.4.1.7262.20.1.2.2.1.5 | Unsigned32 | read-only | The number of variables in equipmentEventLogVariableTable for this
logged notification. |
| equipmentEventLogVariableTable | 1.3.6.1.4.1.7262.20.1.2.3 | | not-accessible | A table of variables to go with Notification log entries. |
| equipmentEventLogVariableEntry | 1.3.6.1.4.1.7262.20.1.2.3.1 | | not-accessible | A Notification log entry variable.
Entries appear in this table when there are variables in
the varbind list of a Notification in equipmentEventLogTable. |
| U32 equipmentEventLogVariableIndex | 1.3.6.1.4.1.7262.20.1.2.3.1.1 | Unsigned32 | not-accessible | A monotonically increasing integer, starting at 1 for a given
equipmentEventLogIndex, for indexing variables within the logged
Event Notification. |
| OID equipmentEventLogVariableID | 1.3.6.1.4.1.7262.20.1.2.3.1.2 | OBJECT IDENTIFIER | read-only | The variable's object identifier. |
| INT equipmentEventLogVariableValueType | 1.3.6.1.4.1.7262.20.1.2.3.1.3 | INTEGER | read-only | The type of the value. One and only one of the value
objects that follow must be instantiated, based on this type. |
| C32 equipmentEventLogVariableCounter32Val | 1.3.6.1.4.1.7262.20.1.2.3.1.4 | Counter32 | read-only | The value when equipmentEventLogVariableValueType is 'counter32'. |
| U32 equipmentEventLogVariableUnsigned32Val | 1.3.6.1.4.1.7262.20.1.2.3.1.5 | Unsigned32 | read-only | The value when equipmentEventLogVariableValueType is 'unsigned32'. |
| TIK equipmentEventLogVariableTimeTicksVal | 1.3.6.1.4.1.7262.20.1.2.3.1.6 | TimeTicks | read-only | The value when equipmentEventLogVariableValueType is 'timeTicks'. |
| I32 equipmentEventLogVariableInteger32Val | 1.3.6.1.4.1.7262.20.1.2.3.1.7 | Integer32 | read-only | The value when equipmentEventLogVariableValueType is 'integer32'. |
| OCT equipmentEventLogVariableOctetStringVal | 1.3.6.1.4.1.7262.20.1.2.3.1.8 | OCTET STRING | read-only | The value when equipmentEventLogVariableValueType is 'octetString'. |
| IP equipmentEventLogVariableIpAddressVal | 1.3.6.1.4.1.7262.20.1.2.3.1.9 | IpAddress | read-only | The value when equipmentEventLogVariableValueType is 'ipAddress'.
Although this seems to be unfriendly for IPv6, we
have to recognize that there are a number of older
MIBs that do contain an IPv4 format address, known
as IpAddress.
IPv6 addresses are represented using TAddress or
InetAddress, and so the underlying datatype is
OCTET STRING, and their value would be stored in
the equipmentEventLogVariableOctetStringVal column. |
| OID equipmentEventLogVariableOidVal | 1.3.6.1.4.1.7262.20.1.2.3.1.10 | OBJECT IDENTIFIER | read-only | The value when equipmentEventLogVariableValueType is 'objectId'. |
| C64 equipmentEventLogVariableCounter64Val | 1.3.6.1.4.1.7262.20.1.2.3.1.11 | Counter64 | read-only | The value when equipmentEventLogVariableValueType is 'counter64'. |
| equipmentAlarmList | 1.3.6.1.4.1.7262.20.1.3 | | | |
| TIK equipmentAlarmActiveLastChanged | 1.3.6.1.4.1.7262.20.1.3.1 | TimeTicks | read-only | The value of sysUpTime at the time of the last
creation or deletion of an entry in the equipmentAlarmActiveTable.
Useful in case of polling (no traps mechanism used).
If the number of entries has been unchanged since the
last re-initialization, then this object contains a zero value. |
| C32 equipmentAlarmActiveRowCounterEx | 1.3.6.1.4.1.7262.20.1.3.2 | Counter32 | read-only | The number of active alarms row in the table. |
| equipmentAlarmActiveTable | 1.3.6.1.4.1.7262.20.1.3.3 | | not-accessible | A table of Active Alarms entries. |
| equipmentAlarmActiveEntry | 1.3.6.1.4.1.7262.20.1.3.3.1 | | not-accessible | Entries appear in this table when alarms are raised. They
are removed when the alarm is cleared. |
| U32 equipmentAlarmActiveIndex | 1.3.6.1.4.1.7262.20.1.3.3.1.1 | Unsigned32 | not-accessible | A strictly monotonically increasing integer which
acts as the index of entries within the named alarm
list. It wraps back to 1 after it reaches its
maximum value. |
| TIM equipmentAlarmActiveTime | 1.3.6.1.4.1.7262.20.1.3.3.1.2 | TimeStamp | not-accessible | The value of sysUpTime when the entry was placed in the list.
This object facilitates retrieving all instances of
alarms that have been raised or have changed state
since a given point in time. |
| DAT equipmentAlarmActiveDateAndTime | 1.3.6.1.4.1.7262.20.1.3.3.1.3 | DateAndTime | read-only | The local date and time when the error occurred.
This object facilitates retrieving all instances of
alarms that have been raised or have changed state
since a given point in time.
Implementations MUST include the offset from UTC,
if available. Implementation in environments in which
the UTC offset is not available is NOT RECOMMENDED. |
| STR equipmentAlarmActiveName | 1.3.6.1.4.1.7262.20.1.3.3.1.4 | DisplayString | read-only | This object indicates the active alarm name. |
| I32 equipmentAlarmActiveID | 1.3.6.1.4.1.7262.20.1.3.3.1.5 | Integer32 | read-only | This object indicates the active alarm ID which is the index to the alarm configuration table defined in product specific MIB. |
| U32 equipmentAlarmActiveInstance | 1.3.6.1.4.1.7262.20.1.3.3.1.6 | Unsigned32 | read-only | |
| OID equipmentAlarmActiveTrapOID | 1.3.6.1.4.1.7262.20.1.3.3.1.7 | OBJECT IDENTIFIER | read-only | The MIB object identifier of the alarm (contained in an Alarm Notification
type object) that is occurring. |
| INT equipmentAlarmActiveSeverity | 1.3.6.1.4.1.7262.20.1.3.3.1.8 | INTEGER | read-only | This object indicates the active alarm severity. |
| STR equipmentAlarmActiveConditionId | 1.3.6.1.4.1.7262.20.1.3.3.1.9 | DisplayString | read-only | |
| equipmentSnmpTrap | 1.3.6.1.4.1.7262.20.1.4 | | | |
| C32 equipmentOutTrapsCounter | 1.3.6.1.4.1.7262.20.1.4.1 | Counter32 | read-only | The counter of the output traps.
It increases by one every time a new trap is sent to all the managers configured
in the relevant table. In this way its value is the number of notification events
occurred since the last agent reset and every manager that reads this value can understand
whether some event has been lost or not.
(Note that in general this counter differs from the RFC1213 snmpOutTraps, that counts the
number of Trap PDUs sent). When the logging mechanism is enabled, it corresponds to the index in the eventlog table |
| TIM equipmentLastOutTrapTimeStamp | 1.3.6.1.4.1.7262.20.1.4.2 | TimeStamp | read-only | The value of sysUpTime when the last trap was sent. |
| STR equipmentTrapInfo | 1.3.6.1.4.1.7262.20.1.4.3 | DisplayString | read-only | A string representing additional info that can be used as the varbind in trap. |
| equipmentPseudoEventsObjects | 1.3.6.1.4.1.7262.20.2 | | | |
| OID equipmentConfChangeOid | 1.3.6.1.4.1.7262.20.2.1 | OBJECT IDENTIFIER | read-only | The OID of the last node changed. It is sent to the managers in order to
notify a configuration change. |
| ENA equipmentConfChangeMode | 1.3.6.1.4.1.7262.20.2.2 | EnableType | read-write | Enable/Disable of sending ConfChange Trap.
STORAGE: permanent. |
| NTF equipmentConfChangeNotification | 1.3.6.1.4.1.7262.20.2.3 | | | Notification of configuration change. |
| equipmentMirrorObjects | 1.3.6.1.4.1.7262.20.3 | | | |
| I32 equipmentMirrorFlag | 1.3.6.1.4.1.7262.20.3.1 | Integer32 | read-only | Fixed to 1=mirror trap |
| NTF equipmentMirrorColdStart | 1.3.6.1.4.1.7262.20.3.2 | | | A coldStart trap signifies that the SNMP entity,
supporting a notification originator application, is
reinitializing itself and that its configuration may
have been altered. |
| equipmentCommonMib | 1.3.6.1.4.1.7262.20.100 | | | This MIB Module defines a notification log mechanism and a current alarm list. |