| OID symbolic | OID numeric | Type | Access | Description |
| ciscoC8500RedundancyMIB | 1.3.6.1.4.1.9.9.105 | | | This MIB allows management of redundancy of CPU and
switch cards for the Catalyst 8540 switch, and other
products with similar implementations.
The Catalyst 8540 is an ATM switch. It has 13 (or, in
some models, 14) slots, of which 2 slots can hold CPU
cards, and 3 (or, in some models, 4) slots can hold
switch cards. A switch card is one that contains the
ATM switching fabric. Two switch cards are combined
to operate in 20Gbps switching mode.
For CPU cards, 1+1 redundancy is supported.
For switch cards, 2+1 redundancy is supported. |
| ciscoC8500RedundancyMIBObjects | 1.3.6.1.4.1.9.9.105.1 | | | |
| ccrCpu | 1.3.6.1.4.1.9.9.105.1.1 | | | |
| ccrCpuTable | 1.3.6.1.4.1.9.9.105.1.1.1 | | not-accessible | There is an entry in this table for each slot that
can hold a CPU card. |
| ccrCpuEntry | 1.3.6.1.4.1.9.9.105.1.1.1.1 | | not-accessible | Redundancy information for a CPU card. |
| RED ccrCpuSlotIndex | 1.3.6.1.4.1.9.9.105.1.1.1.1.1 | RedundancySlotIndex | not-accessible | Identifies a chassis slot. |
| RED ccrCpuMode | 1.3.6.1.4.1.9.9.105.1.1.1.1.2 | RedundancyMode | read-write | The redundancy mode of this CPU card. |
| RED ccrCpuStatus | 1.3.6.1.4.1.9.9.105.1.1.1.1.3 | RedundancyStatus | read-only | The operational status of this CPU card. |
| BIT ccrSyncConfigOnSet | 1.3.6.1.4.1.9.9.105.1.1.2 | Bits | read-write | The device's running-configuration and
startup-configuration both reside on the active CPU
card. This object indicates whether these
configurations should be copied from the active CPU
to the standby CPU whenever they change. It is
acceptable to copy either, both, or neither. |
| T/F ccrCpuStandbyEnableMode | 1.3.6.1.4.1.9.9.105.1.1.3 | TruthValue | read-write | This object is used to allow or disallow the
execution of the enable exec command on the
secondary CPU.
When set to 'true', the enable exec command can be
executed on secondary CPU, and the user may enter
enable mode after keying in the password configured.
When set to 'false', the enable exec command cannot
be executed; thus, no user may enter enabled mode. |
| INT ccrCpuSwitchoverTime | 1.3.6.1.4.1.9.9.105.1.1.4 | INTEGER | read-only | The time taken for the most recent CPU switchover. |
| INT ccrForceCounterSync | 1.3.6.1.4.1.9.9.105.1.1.5 | INTEGER | read-write | This object is used to force the synchronization of
counters from primary CPU to secondary CPU. It should
generally be set just before a controlled Route
Processor Switchover.
When this object is retrieved, the value 'noop' is
returned. When this object is set to 'noop' no
operation is performed. |
| INT ccrIfCounterSyncFreq | 1.3.6.1.4.1.9.9.105.1.1.6 | INTEGER | read-write | This object configures the periodicity of interface
counter synchronization from primary CPU to
secondary CPU. Setting this object to 0 will disable
counter synchronization. |
| INT ccrVcCounterSyncFreq | 1.3.6.1.4.1.9.9.105.1.1.7 | INTEGER | read-write | This object configures the periodicity of Virtual
Circuit (VC) counter synchronization from primary CPU
to secondary CPU. Setting this object to 0 will
disable counter synchronization. |
| T/F ccrSigCounterSyncEnable | 1.3.6.1.4.1.9.9.105.1.1.8 | TruthValue | read-write | This object configures the synchronization of ATM
Signalling Statistics from primary CPU to
secondary CPU.
When this object is set to 'true', sychronization
is enabled. When this object is set to 'false',
synchronization is disabled. |
| ccrSwitch | 1.3.6.1.4.1.9.9.105.1.2 | | | |
| ccrSwitchTable | 1.3.6.1.4.1.9.9.105.1.2.1 | | not-accessible | There is an entry in this table for each slot that
can hold a switch card. A 'switch card' is a card that
contains the ATM switch fabric. |
| ccrSwitchEntry | 1.3.6.1.4.1.9.9.105.1.2.1.1 | | not-accessible | Redundancy information for a switch card. |
| RED ccrSwitchSlotIndex | 1.3.6.1.4.1.9.9.105.1.2.1.1.1 | RedundancySlotIndex | not-accessible | Identifies a chassis slot. |
| RED ccrSwitchMode | 1.3.6.1.4.1.9.9.105.1.2.1.1.2 | RedundancyMode | read-write | The redundancy mode of this switch card. |
| RED ccrSwitchStatus | 1.3.6.1.4.1.9.9.105.1.2.1.1.3 | RedundancyStatus | read-only | The operational status of this switch card. |
| TIM ccrSwitchLastSwitchoverTime | 1.3.6.1.4.1.9.9.105.1.2.2 | TimeStamp | read-only | The value of sysUpTime at the last switchover of the
switch cards.
The value is zero if there was no switchover since
agent initialization. |
| INT ccrSwitchLastSwitchoverReason | 1.3.6.1.4.1.9.9.105.1.2.3 | INTEGER | read-only | The reason for the last switch card switchover.
The value is none(1) if there was no switchover since
agent initialization. |
| INT ccrSwitchBw | 1.3.6.1.4.1.9.9.105.1.2.4 | INTEGER | read-only | The switching capacity (i.e., bandwidth) of the
switch fabric.
tenGbps(1) - 10 Gigabits/sec
twentyGbps(2) - 20 Gigabits/sec. |
| INT ccrDesiredSwitchBw | 1.3.6.1.4.1.9.9.105.1.2.5 | INTEGER | read-write | The desired switching capacity (i.e., bandwidth) of
the switch fabric.
tenGbps(1) - 10 Gigabits/sec
twentyGbps(2) - 20 Gigabits/sec
If the value configured by writing to this object is
supported by the device, it will be applied at the
next reboot. The speed at which the switch fabric is
currently operating is reflected by the value of
ccrSwitchBw. |
| ciscoC8500RedundancyMIBNotificationPrefix | 1.3.6.1.4.1.9.9.105.2 | | | |
| ccrMIBNotifications | 1.3.6.1.4.1.9.9.105.2.0 | | | |
| NTF ccrCpuStatusChange | 1.3.6.1.4.1.9.9.105.2.0.1 | | | This notification is generated when the value of
ccrCpuStatus changes for a CPU card.
The varbind indicates the current status of the
affected card. |
| NTF ccrSwitchStatusChange | 1.3.6.1.4.1.9.9.105.2.0.2 | | | This notification is generated when the value of
ccrSwitchStatus changes for a switch card.
The varbind indicates the current status of the
affected card. |
| NTF ccrSwitchModeChange | 1.3.6.1.4.1.9.9.105.2.0.3 | | | This notification is generated when the value of
ccrSwitchMode changes from active(1) to either
standby(2) or unused(3) or notPresent(4).
The varbind indicates the current mode of the
affected card. |
| ciscoC8500RedundancyMIBConformance | 1.3.6.1.4.1.9.9.105.3 | | | |
| ciscoC8500RedundancyMIBCompliances | 1.3.6.1.4.1.9.9.105.3.1 | | | |
| ciscoC8500RedundancyMIBCompliance | 1.3.6.1.4.1.9.9.105.3.1.1 | | | The compliance statement for Cisco agents which
implement the CISCO-C8500-REDUNDANCY-MIB. |
| ciscoC8500RedundancyMIBComplianceRev1 | 1.3.6.1.4.1.9.9.105.3.1.2 | | | The compliance statement to include objects
related to the redundancy features like
enable password on secondary, switchover
duration and counter. |
| ciscoC8500RedundancyMIBGroups | 1.3.6.1.4.1.9.9.105.3.2 | | | |
| ccrCpuMibGroup | 1.3.6.1.4.1.9.9.105.3.2.1 | | | A collection of objects providing the ability to
manage CPU card redundancy. |
| ccrSwitchMibGroup | 1.3.6.1.4.1.9.9.105.3.2.2 | | | A collection of objects providing the ability to
manage Switch Fabric card redundancy. |
| ccrNotificationsGroup | 1.3.6.1.4.1.9.9.105.3.2.3 | | | A collection of notifications related to redundancy. |
| ccrCpuMibGroup1 | 1.3.6.1.4.1.9.9.105.3.2.4 | | | A collection of objects providing the ability to
manage CPU card redundancy and redundancy feature
for counter, enable password on secondary and
switchover duration. |