All MIBs › HUAWEI-ENTITY-EXTENT-MIB
Organization: Huawei Technologies Co.,Ltd.
Last Updated: 2014-09-17
Category: Hardware and Environment, Optical and WDM, Vendor: Huawei
Description: Extends the standard Entity MIB for Huawei devices, providing CPU utilization, memory usage, entity operational/admin status, optical module parameters, and hardware production information.
IPNetwork Monitor uses several OIDs from this MIB in network discovery and polling the applicable devices. Start monitoring HUAWEI-ENTITY-EXTENT-MIB with a free 30-day trial of IPNetwork Monitor.
What Is HUAWEI-ENTITY-EXTENT-MIB?
HUAWEI-ENTITY-EXTENT-MIB extends the standard IETF ENTITY-MIB with Huawei-specific hardware management objects for Huawei routers and switches. It exposes data covering CPU utilization, memory usage, entity administrative and operational status, optical transceiver module parameters, and hardware production/manufacturing information. This MIB is squarely a hardware health-monitoring module: it tracks CPU load, memory consumption, whether physical entities (cards, modules, ports) are administratively enabled and operationally up, plus optical module diagnostics and production/serial data useful for asset tracking. It explicitly depends on and extends the standard ENTITY-MIB, reusing its physical entity indexing while adding Huawei-private columns. It is deployed in Huawei carrier and enterprise network devices as a core building block for NMS dashboards that show chassis health and hardware inventory. Engineers can download the HUAWEI-ENTITY-EXTENT-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in HUAWEI-ENTITY-EXTENT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Huawei routers
- Huawei switches
- Huawei network devices with entity-based hardware inventory
Monitoring Examples
An NMS would poll the extended entity table to read CPU and memory utilization per entity index and correlate it with the standard entPhysicalTable to identify which card or module is under load, while also checking optical module parameters for transceivers plugged into that entity. If entity operational status flips to down for a linecard while admin status remains up, that signals an unexpected hardware fault. Sustained elevated CPU or memory readings can indicate a control-plane process consuming excessive resources.
What Can Be Monitored
- CPU utilization
- memory usage
- entity admin/operational status
- optical module Tx/Rx parameters
- hardware production/serial information
This MIB depends on
Related MIBs
Imported Objects
From ENTITY-MIB
| PhysicalClass | |
| PhysicalIndex | |
| entPhysicalIndex | OBJECT-TYPE |
| entPhysicalName | OBJECT-TYPE |
| entPhysicalVendorType | OBJECT-TYPE |
From HUAWEI-MIB
| hwDatacomm | OBJECT-IDENTITY |
From IF-MIB
| InterfaceIndex |
From P-BRIDGE-MIB
| EnabledStatus |
From SNMP-FRAMEWORK-MIB
| SnmpAdminString |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter64 | |
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| AutonomousType | |
| DateAndTime | |
| DisplayString | |
| RowStatus | |
| TEXTUAL-CONVENTION |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| hwEntityExtentMIB | 1.3.6.1.4.1.2011.5.25.31 | The private mib file includes the general extent information of the device. | ||
| hwEntityExtObjects | 1.3.6.1.4.1.2011.5.25.31.1 | |||
| hwEntityState | 1.3.6.1.4.1.2011.5.25.31.1.1 | |||
| hwEntityStateTable | 1.3.6.1.4.1.2011.5.25.31.1.1.1 | not-accessible | This table contains one row per physical entity, There is always at least one row for an 'overall' physical entity. The information in each row may be not include all the object in this table, because of the entity need not some of the information here. | |
| hwEntityStateEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1 | not-accessible | Information about a particular physical entity. Each entry provides objects (entPhysicalDescr, entPhysicalVendorType, and entPhysicalClass) to help an NMS identify and characterize the entry, and objects (entPhysicalContainedIn and entPhysicalParentRelPos) to help an NMS relate the particular entry to other entries in this table. | |
| HWA hwEntityAdminStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.1 | HwAdminState | read-write | The administrative state for this object, and it is possible to set the state when needed. |
| HWO hwEntityOperStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 | HwOperState | read-only | The operational state for this object. |
| HWS hwEntityStandbyStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.3 | HwStandbyStatus | read-only | Some entity in a device can support standby mode, This object is used for monitoring standby status. |
| HWA hwEntityAlarmLight | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.4 | HwAlarmStatus | read-only | The alarm status for this entity. It does not include the severity of alarms raised on child components. On the condition, there are a alarm light on the entity, the object should have the same status with it. |
| I32 hwEntityCpuUsage | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.5 | Integer32 | read-only | The CPU usage for this entity. Generally, the CPU usage will calculate the overall CPU usage on the entity, and it is not sensible with the number of CPU on the entity. |
| I32 hwEntityCpuUsageThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.6 | Integer32 | read-write | The threshold for the CPU usage. When the CPU usage exceed the threshold, a notification will be sent. |
| I32 hwEntityMemUsage | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.7 | Integer32 | read-only | The memory usage for the entity. This object point out how many percent of memory has been used. |
| I32 hwEntityMemUsageThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.8 | Integer32 | read-write | The threshold for the Memory usage, When the memory usage exceed the threshold, a notification will be sent. |
| I32 hwEntityMemSize | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.9 | Integer32 | read-only | The size of memory for the entity. |
| I32 hwEntityUpTime | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.10 | Integer32 | read-only | The up time for the entity. The mean of up time is when the entity is up, and the value of the object will add one per seconds while the entity running. |
| I32 hwEntityTemperature | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.11 | Integer32 | read-only | The temperature for the entity. The value 0X7FFFFFF indicates invalid temperature. |
| I32 hwEntityTemperatureThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.12 | Integer32 | read-write | The threshold for the temperature. When the temperature exceeds the threshold, a notification will be sent. |
| I32 hwEntityVoltage | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.13 | Integer32 | read-only | The voltage for the entity. |
| I32 hwEntityVoltageLowThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.14 | Integer32 | read-write | The low-threshold for the voltage. Generally, we have two threshold for the voltage, one is low-threshold, and the other is high-threshold. the normal status of voltage should be greater than the low-threshold, and lower than the high-threshold. When the voltage low than the low-threshold, a notification will be sent. |
| I32 hwEntityVoltageHighThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.15 | Integer32 | read-write | The high-threshold for the voltage. Generally, we have two threshold for the voltage, one is low-threshold, and the other is high-threshold. the normal status of voltage should be greater than the low-threshold, and lower than the high-threshold. When the voltage greater than the high-threshold, a notification will be sent. |
| I32 hwEntityTemperatureLowThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.16 | Integer32 | read-write | The low-threshold of temperature. If the device temperature is lower than the threshold, an alarm is raised. |
| I32 hwEntityOpticalPower | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.17 | Integer32 | read-only | The optical power of the optical module. Unit: uW |
| I32 hwEntityCurrent | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.18 | Integer32 | read-only | The current for the entity. |
| I32 hwEntityMemSizeMega | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.19 | Integer32 | read-only | The size of SDRAM(Synchronous Dynamic Random Access Memory) memory for the entity. Unit: M bytes |
| INT hwEntityPortType | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.20 | INTEGER | read-only | Indicates the type of the Ethernet interface: an optical interface or an electrical interface. |
| INT hwEntityDuplex | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.21 | INTEGER | read-only | Indicates the duplex mode of the Ethernet interface. An electrical Ethernet interface can work in half-duplex mode or full-duplex mode. An optical Ethernet can work only in full-duplex mode. |
| I32 hwEntityOpticalPowerRx | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.22 | Integer32 | read-only | The optical power(Rx) of the optical module. Unit: uW |
| I32 hwEntityCpuUsageLowThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.23 | Integer32 | read-write | The threshold for the CPU usage. When the CPU usage exceed the threshold, a notification will be sent. |
| I32 hwEntityBoardPower | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.24 | Integer32 | read-only | The board power for the entity. Unit: W |
| I32 hwEntityCpuFrequency | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.25 | Integer32 | read-only | The frequency of the entity. Unit: Hz |
| INT hwEntitySupportFlexCard | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.26 | INTEGER | read-only | It describes whether the whole board supports flexible cards. When the board doesn't support flexible cards, the cards may be dummy ones whose ports will not be seen by the customer. |
| INT hwEntityBoardClass | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.27 | INTEGER | read-only | It describes the board type of the whole board. |
| I32 hwNseOpmStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.28 | Integer32 | read-only | OPM status. 0: pass, 1: bypass, 2: invalid |
| I32 hwEntityCpuMaxUsage | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.29 | Integer32 | read-only | The Max CPU usage for this entity. Generally, the Max CPU usage will calculate the overall CPU usage on the entity, and it is not sensible with the number of CPU on the entity. |
| STR hwEntityCPUType | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.30 | SnmpAdminString | read-only | CPU type. |
| STR hwEntityMemoryType | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.31 | SnmpAdminString | read-only | Memory type. |
| I32 hwEntityFlashSize | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.32 | Integer32 | read-only | Flash size, in KB. |
| I32 hwEntityIfUpTimes | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.33 | Integer32 | read-only | Times that the interface goes Up. |
| I32 hwEntityIfDownTimes | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.34 | Integer32 | read-only | Times that the interface goes Down. |
| I32 hwEntityCPUAvgUsage | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.35 | Integer32 | read-only | Average CPU usage within a specified statistical interval. |
| I32 hwEntityMemoryAvgUsage | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.36 | Integer32 | read-only | Average memory usage within a specified statistical interval. |
| U32 hwEntityMemUsed | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.37 | Unsigned32 | read-only | The memory information for the entity. This object indicates how many bytes in the memory have been used. |
| I32 hwEntityTotalFanNum | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.38 | Integer32 | read-only | The total numbers of the fans in the chassis . |
| I32 hwEntityNomalFanNum | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.39 | Integer32 | read-only | The Nomal numbers of the fans in the chassis . |
| I32 hwEntityTotalPwrNum | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.40 | Integer32 | read-only | The total numbers of the powers in the chassis . |
| I32 hwEntityNomalPwrNum | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.41 | Integer32 | read-only | The nomal numbers of the powers in the chassis . |
| INT hwEntityFaultLight | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.42 | INTEGER | read-write | The repair status for this entity. On the underrepair condition, there is a blue light on the entity. |
| OCT hwEntityBoardName | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.43 | OCTET STRING | read-only | The board name for this entity. |
| OCT hwEntityBoardDescription | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.44 | OCTET STRING | read-only | The board description for this entity. |
| I32 hwEntity5MinCpuUsage | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.45 | Integer32 | read-only | Average CPU usage of the last five minutes for this entity. |
| INT hwEntityStartMode | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.46 | INTEGER | read-only | The start mode of board. |
| OCT hwEntitySplitAttribute | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.47 | OCTET STRING | read-only | The attribute for the split port. |
| I32 hwEntityFaultLightKeepTime | 1.3.6.1.4.1.2011.5.25.31.1.1.1.1.48 | Integer32 | read-write | Fault light twinkle keep time,the default is 45 seconds. |
| hwRUModuleInfoTable | 1.3.6.1.4.1.2011.5.25.31.1.1.2 | not-accessible | This table contains one row per replaceable unit physical entity. The row with the field 'entPhysicalIsFRU' sets to 'true' in table 'entPhysicalTable' will be mapped to one row in this table. | |
| hwRUModuleInfoEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.2.1 | not-accessible | Information about a replaceable unit physical entity. Each entry provides objects of a replaceable unit to help an NMS identify and characterize the entry in this table. | |
| STR hwEntityBomId | 1.3.6.1.4.1.2011.5.25.31.1.1.2.1.1 | SnmpAdminString | read-only | The identity of the Bill of Material about this replaceable unit which coded by vendor. This node is mapping to 'ITEM' in the information file. |
| STR hwEntityBomEnDesc | 1.3.6.1.4.1.2011.5.25.31.1.1.2.1.2 | SnmpAdminString | read-only | The English description of the Bill of Material about this replaceable unit. |
| STR hwEntityBomLocalDesc | 1.3.6.1.4.1.2011.5.25.31.1.1.2.1.3 | SnmpAdminString | read-only | The local description of the Bill of Material about this replaceable unit. |
| DAT hwEntityManufacturedDate | 1.3.6.1.4.1.2011.5.25.31.1.1.2.1.4 | DateAndTime | read-only | The date when this physical entity is Manufactured. |
| I32 hwEntityManufactureCode | 1.3.6.1.4.1.2011.5.25.31.1.1.2.1.5 | Integer32 | read-only | The code of the place where this physical entity is Manufactured. |
| STR hwEntityCLEICode | 1.3.6.1.4.1.2011.5.25.31.1.1.2.1.6 | SnmpAdminString | read-only | The string code of CLEI which was granted by America. |
| STR hwEntityUpdateLog | 1.3.6.1.4.1.2011.5.25.31.1.1.2.1.7 | SnmpAdminString | read-only | The maintenance log of this replaceable unit. |
| STR hwEntityArchivesInfoVersion | 1.3.6.1.4.1.2011.5.25.31.1.1.2.1.8 | SnmpAdminString | read-only | The Version of Archives Information. |
| STR hwEntityOpenBomId | 1.3.6.1.4.1.2011.5.25.31.1.1.2.1.9 | SnmpAdminString | read-only | The BomId for distribution. It is different from hwEntityBomId. |
| STR hwEntityIssueNum | 1.3.6.1.4.1.2011.5.25.31.1.1.2.1.10 | SnmpAdminString | read-only | The issue number for hardware change. |
| STR hwEntityBoardType | 1.3.6.1.4.1.2011.5.25.31.1.1.2.1.11 | SnmpAdminString | read-only | The type code for entity. |
| hwOpticalModuleInfoTable | 1.3.6.1.4.1.2011.5.25.31.1.1.3 | not-accessible | Table of optical module properties. | |
| hwOpticalModuleInfoEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1 | not-accessible | An entry in the table of optical module properties for each optical module. | |
| INT hwEntityOpticalMode | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.1 | INTEGER | read-only | The mode of the optical module. |
| I32 hwEntityOpticalWaveLength | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.2 | Integer32 | read-only | The wave length of the optical module. Unit: nm. |
| I32 hwEntityOpticalTransDistance | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.3 | Integer32 | read-only | The max transmission distance of the optical module. Unit: m. |
| STR hwEntityOpticalVendorSn | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.4 | SnmpAdminString | read-only | The vendor serial number (vendor SN) of the optical module. Length: 16 bytes. |
| I32 hwEntityOpticalTemperature | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.5 | Integer32 | read-only | The current temperature of the optical module. Unit: C |
| I32 hwEntityOpticalVoltage | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.6 | Integer32 | read-only | The current voltage of the optical module. Unit: mV. |
| I32 hwEntityOpticalBiasCurrent | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.7 | Integer32 | read-only | The bias current of the optical module. Unit: mA. |
| I32 hwEntityOpticalRxPower | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.8 | Integer32 | read-only | The receive power of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times |
| I32 hwEntityOpticalTxPower | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.9 | Integer32 | read-only | The transmit power of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times |
| INT hwEntityOpticalType | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.10 | INTEGER | read-only | The type of the optical module. |
| I32 hwEntityOpticalTransBW | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.11 | Integer32 | read-only | The Transceiver max BW of the optical module.Unit:M |
| INT hwEntityOpticalFiberType | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.12 | INTEGER | read-only | The Fiber type of the optical module. |
| I32 hwEntityOpticalRxLowThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.13 | Integer32 | read-only | The receive power low threshold of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times |
| I32 hwEntityOpticalRxHighThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.14 | Integer32 | read-only | The receive power high threshold of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times |
| I32 hwEntityOpticalTxLowThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.15 | Integer32 | read-only | The transmit power low threshold of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times |
| I32 hwEntityOpticalTxHighThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.16 | Integer32 | read-only | The transmit power high threshold of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times |
| INT hwEntityOpticalPlug | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.17 | INTEGER | read-only | The optical module is plug-supported or not. |
| INT hwEntityOpticalDirectionType | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.18 | INTEGER | read-only | The direction type of the optical module. |
| STR hwEntityOpticalUserEeprom | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.19 | DisplayString | read-only | The user writable EEPROM of the optical module. |
| I32 hwEntityOpticalRxLowWarnThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.20 | Integer32 | read-only | The receive power low warning threshold of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times |
| I32 hwEntityOpticalRxHighWarnThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.21 | Integer32 | read-only | The receive power high warning threshold of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times |
| I32 hwEntityOpticalTxLowWarnThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.22 | Integer32 | read-only | The transmit power low warning threshold of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times |
| I32 hwEntityOpticalTxHighWarnThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.23 | Integer32 | read-only | The transmit power high warning threshold of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times |
| STR hwEntityOpticalVenderName | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.24 | DisplayString | read-only | The Vender Name of the optical module. |
| STR hwEntityOpticalVenderPn | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.25 | DisplayString | read-only | The Vender PN of the optical module. |
| INT hwEntityOpticalAuthenticationStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.26 | INTEGER | read-only | The authentication status of optical module. |
| INT hwEntityOpticalTunableType | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.27 | INTEGER | read-only | The tunable type of the optical module. |
| I32 hwEntityOpticalWaveLengthDecimal | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.28 | Integer32 | read-only | The Decimal wavelength of the optical module. Unit: nm. The value is expanded 1000 times,so the real value should be reduced 1000 times. |
| I32 hwEntityOpticalTunableModuleChannel | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.29 | Integer32 | read-only | The current channel of tunable optical module. |
| INT hwEntityOpticalWaveBand | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.30 | INTEGER | read-only | The wave band of the optical module. |
| STR hwEntityOpticalLaneBiasCurrent | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.31 | SnmpAdminString | read-only | The bias current of the QSFP or CFP optical module. Unit: mA.(e.g., 37.88,39.15,39.84,37.82) |
| STR hwEntityOpticalLaneRxPower | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.32 | SnmpAdminString | read-only | The receive power of the QSFP or CFP optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times (e.g., 114,32,-90,-228) |
| STR hwEntityOpticalLaneTxPower | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.33 | SnmpAdminString | read-only | The transmit power of the QSFP or CFP optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times (e.g., 94,-39,33,-58) |
| STR hwEntityOpticalVendorOUI | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.34 | DisplayString | read-only | Vendor ID of the optical module assigned by IEEE. |
| STR hwEntityOpticalVendorRev | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.35 | DisplayString | read-only | The Vender Version of the optical module. |
| STR hwEntityOpticalGponSN | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.36 | DisplayString | read-only | The SN of the optical module provided by the vendor. |
| hwMonitorInputTable | 1.3.6.1.4.1.2011.5.25.31.1.1.4 | not-accessible | This table contains one row per replaceable unit physical entity. This table is used to set the status of monitor port. | |
| hwMonitorInputEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.4.1 | not-accessible | This is a replaceable unit physical entity. | |
| I32 hwMonitorInputIndex | 1.3.6.1.4.1.2011.5.25.31.1.1.4.1.1 | Integer32 | not-accessible | Monitor port index. This is a number of input line,ranging from 1 to 4. |
| STR hwMonitorInputName | 1.3.6.1.4.1.2011.5.25.31.1.1.4.1.2 | DisplayString | read-create | Monitor line name. |
| HWL hwMonitorInputState | 1.3.6.1.4.1.2011.5.25.31.1.1.4.1.3 | HWLevelState | read-create | Monitor line status. The value is high or low. |
| ENA hwMonitorInputStateEnable | 1.3.6.1.4.1.2011.5.25.31.1.1.4.1.4 | EnabledStatus | read-create | Enable monitor line. |
| ROW hwMonitorInputRowStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.4.1.5 | RowStatus | read-create | Status of monitor input row. |
| hwMonitorOutputTable | 1.3.6.1.4.1.2011.5.25.31.1.1.5 | not-accessible | This table contains one row per replaceable unit physical entity. This table is used to create a output view. | |
| hwMonitorOutputEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.5.1 | not-accessible | This is a replaceable unit physical entity. | |
| I32 hwMonitorOutputIndex | 1.3.6.1.4.1.2011.5.25.31.1.1.5.1.1 | Integer32 | not-accessible | Monitor output view index. Through this index ,you can turn into the output view. |
| I32 hwMonitorOutputRuleIndex | 1.3.6.1.4.1.2011.5.25.31.1.1.5.1.2 | Integer32 | not-accessible | Monitor output rule index. This is used to set the rules about all of the input line. |
| STR hwMonitorOutputMask | 1.3.6.1.4.1.2011.5.25.31.1.1.5.1.3 | DisplayString | read-create | Monitor output mask . This is used to matching the level of monitor input line. |
| STR hwMonitorOutputKey | 1.3.6.1.4.1.2011.5.25.31.1.1.5.1.4 | DisplayString | read-create | Normal level value of this output line. |
| ROW hwMonitorOutputRowStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.5.1.5 | RowStatus | read-create | Status of monitor input row |
| hwEntPowerUsedInfoTable | 1.3.6.1.4.1.2011.5.25.31.1.1.6 | not-accessible | A table of information that displays the power use of entity . | |
| hwEntPowerUsedInfoEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.6.1 | not-accessible | Entry of the table of information that displays the power use of entity. | |
| OCT hwEntPowerUsedInfoBoardName | 1.3.6.1.4.1.2011.5.25.31.1.1.6.1.1 | OCTET STRING | read-only | Board name. |
| OCT hwEntPowerUsedInfoBoardType | 1.3.6.1.4.1.2011.5.25.31.1.1.6.1.2 | OCTET STRING | read-only | Board type. |
| I32 hwEntPowerUsedInfoBoardSlot | 1.3.6.1.4.1.2011.5.25.31.1.1.6.1.3 | Integer32 | read-only | Board's slot number. |
| I32 hwEntPowerUsedInfoPower | 1.3.6.1.4.1.2011.5.25.31.1.1.6.1.4 | Integer32 | read-only | Used power of board. |
| hwVirtualCableTestTable | 1.3.6.1.4.1.2011.5.25.31.1.1.7 | not-accessible | This table contains one row per replaceable unit physical entity. This table is used to display VCT result. | |
| hwVirtualCableTestEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1 | not-accessible | This is a replaceable unit physical entity. | |
| NUM hwVirtualCableTestIfIndex | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.1 | InterfaceIndex | not-accessible | IfIndex of port that you want to test cable. |
| INT hwVirtualCableTestPairStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.2 | INTEGER | read-only | Pair status. This indicate the status of cable. |
| I32 hwVirtualCableTestPairLength | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.3 | Integer32 | read-only | Pair Length. This indicate the length of cable. |
| INT hwVirtualCableTestOperation | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.4 | INTEGER | read-write | VirtualCableTestOperation. This Operation of VirtualCableTest. |
| I32 hwVirtualCableTestLastTime | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.5 | Integer32 | read-only | The last test time for the entity. The mean of last time is when the entity is tested, and the value of the object will add one per seconds until now. |
| INT hwVirtualCableTestPairAStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.6 | INTEGER | read-only | Pair A status. This indicate the status of cable. |
| INT hwVirtualCableTestPairBStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.7 | INTEGER | read-only | Pair B status. This indicate the status of cable. |
| INT hwVirtualCableTestPairCStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.8 | INTEGER | read-only | Pair C status. This indicate the status of cable. |
| INT hwVirtualCableTestPairDStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.9 | INTEGER | read-only | Pair D status. This indicate the status of cable. |
| I32 hwVirtualCableTestPairALength | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.10 | Integer32 | read-only | Pair A Length. This indicate the length of cable. |
| I32 hwVirtualCableTestPairBLength | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.11 | Integer32 | read-only | Pair B Length. This indicate the length of cable. |
| I32 hwVirtualCableTestPairCLength | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.12 | Integer32 | read-only | Pair C Length. This indicate the length of cable. |
| I32 hwVirtualCableTestPairDLength | 1.3.6.1.4.1.2011.5.25.31.1.1.7.1.13 | Integer32 | read-only | Pair D Length. This indicate the length of cable. |
| hwTemperatureThresholdTable | 1.3.6.1.4.1.2011.5.25.31.1.1.8 | not-accessible | This table lists the alarm thresholds of temperature sensors. You can read information about all the temperature sensors of the device. You can set the alarm threshold of a specified temperature sensor. | |
| hwTemperatureThresholdEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.8.1 | not-accessible | Defines an entry in the hwTemperatureThresholdTable. | |
| I32 hwEntityTempSlotId | 1.3.6.1.4.1.2011.5.25.31.1.1.8.1.1 | Integer32 | read-only | This object indicates the slot ID of a temperature sensor. |
| I32 hwEntityTempI2CId | 1.3.6.1.4.1.2011.5.25.31.1.1.8.1.2 | Integer32 | read-only | This object indicates the I2CID of a temperature sensor. |
| I32 hwEntityTempAddr | 1.3.6.1.4.1.2011.5.25.31.1.1.8.1.3 | Integer32 | read-only | This object indicates the address of a temperature sensor. |
| I32 hwEntityTempChannel | 1.3.6.1.4.1.2011.5.25.31.1.1.8.1.4 | Integer32 | read-only | This object indicates the channel of a temperature sensor. |
| INT hwEntityTempStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.8.1.5 | INTEGER | read-only | This object indicates the current status of a temperature sensor. |
| I32 hwEntityTempValue | 1.3.6.1.4.1.2011.5.25.31.1.1.8.1.6 | Integer32 | read-only | This object indicates the current value in Celsius of a temperature sensor. |
| I32 hwEntityTempMinorAlmThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.8.1.7 | Integer32 | read-write | This object indicates the threshold for a minor alarm. The value can be set and ranges from 80% to 120% of the default value. The value is in Celsius. |
| I32 hwEntityTempMajorAlmThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.8.1.8 | Integer32 | read-write | This object indicates the threshold for a major alarm. The value can be set and ranges from 80% to 120% of the default value. The value is in Celsius. |
| I32 hwEntityTempFatalAlmThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.8.1.9 | Integer32 | read-write | This object indicates the threshold for a fatal alarm. The value can be set and ranges from 80% to 120% of the default value. The value is in Celsius. |
| hwVoltageInfoTable | 1.3.6.1.4.1.2011.5.25.31.1.1.9 | not-accessible | This table lists information about voltage sensors. You can read information about all the voltage sensors of the device. You can set the alarm threshold of a specified voltage sensor. | |
| hwVoltageInfoEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1 | not-accessible | Defines an entry in the hwVoltageInfoTable. | |
| I32 hwEntityVolSlot | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.1 | Integer32 | read-only | This object indicates the slot ID of a voltage sensor. |
| I32 hwEntityVolI2CId | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.2 | Integer32 | read-only | This object indicates the I2CID of a voltage sensor. |
| I32 hwEntityVolAddr | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.3 | Integer32 | read-only | This object indicates the address of a voltage sensor. |
| I32 hwEntityVolChannel | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.4 | Integer32 | read-only | This object indicates the channel of a voltage sensor. |
| INT hwEntityVolStatus | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.5 | INTEGER | read-only | This object indicates the current status of a voltage sensor. |
| I32 hwEntityVolRequired | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.6 | Integer32 | read-only | This object indicates the nominal value in millivolt of a voltage sensor. |
| I32 hwEntityVolCurValue | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.7 | Integer32 | read-only | This object indicates the current value in millivolt of a voltage sensor. |
| I32 hwEntityVolRatio | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.8 | Integer32 | read-only | This object indicates the voltage ratio of a voltage sensor. |
| I32 hwEntityVolLowAlmMajor | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.9 | Integer32 | read-write | This object indicates the threshold for a major alarm of low voltage. The value can be set and ranges from 80% to 120% of the default value. The value is in millivolt. |
| I32 hwEntityVolLowAlmFatal | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.10 | Integer32 | read-write | This object indicates the threshold for a fatal alarm of low voltage. The value can be set and ranges from 80% to 120% of the default value. The value is in millivolt. |
| I32 hwEntityVolHighAlmMajor | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.11 | Integer32 | read-write | This object indicates the threshold for a major alarm of high voltage. The value can be set and ranges from 80% to 120% of the default value. The value is in millivolt. |
| I32 hwEntityVolHighAlmFatal | 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.12 | Integer32 | read-write | This object indicates the threshold for a fatal alarm of high voltage. The value can be set and ranges from 80% to 120% of the default value. The value is in millivolt. |
| hwFanStatusTable | 1.3.6.1.4.1.2011.5.25.31.1.1.10 | not-accessible | This table lists the status of fans. You can read the status of the fans on the device. | |
| hwFanStatusEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.10.1 | not-accessible | Defines an entry in the hwFanStatusTable. | |
| I32 hwEntityFanSlot | 1.3.6.1.4.1.2011.5.25.31.1.1.10.1.1 | Integer32 | read-only | This object indicates the slot ID of a fan. |
| I32 hwEntityFanSn | 1.3.6.1.4.1.2011.5.25.31.1.1.10.1.2 | Integer32 | read-only | This object indicates the serial number of the fan in a certain slot. |
| INT hwEntityFanReg | 1.3.6.1.4.1.2011.5.25.31.1.1.10.1.3 | INTEGER | read-only | This object indicates whether the fan is registered. |
| INT hwEntityFanSpdAdjMode | 1.3.6.1.4.1.2011.5.25.31.1.1.10.1.4 | INTEGER | read-only | This object indicates the speed adjustment mode of the fan. |
| I32 hwEntityFanSpeed | 1.3.6.1.4.1.2011.5.25.31.1.1.10.1.5 | Integer32 | read-only | This object indicates the rotation speed (in percentage of the full speed) of the fan. |
| INT hwEntityFanPresent | 1.3.6.1.4.1.2011.5.25.31.1.1.10.1.6 | INTEGER | read-only | This object indicates the present information of the fan. |
| INT hwEntityFanState | 1.3.6.1.4.1.2011.5.25.31.1.1.10.1.7 | INTEGER | read-only | This object indicates the state of the fan. |
| OCT hwEntityFanDesc | 1.3.6.1.4.1.2011.5.25.31.1.1.10.1.8 | OCTET STRING | read-only | This object indicates the description of the fan. |
| hwEntityGlobalPara | 1.3.6.1.4.1.2011.5.25.31.1.1.11 | |||
| INT hwEntityServiceType | 1.3.6.1.4.1.2011.5.25.31.1.1.11.1 | INTEGER | read-only | It describes the service-type of spu board . |
| I32 hwDeviceServiceType | 1.3.6.1.4.1.2011.5.25.31.1.1.11.2 | Integer32 | read-only | It describes the service-type of the device. bit0 is WLAN, bit1 is SSLVPN, bit2 is ipsec,other bits temporarily without easy back extension. Each bit 0 is disable, 1 is enable. |
| I32 hwEntityManufacturerOUI | 1.3.6.1.4.1.2011.5.25.31.1.1.11.3 | Integer32 | read-only | It describes the Manufacturer of the device. |
| hwPortBip8StatisticsTable | 1.3.6.1.4.1.2011.5.25.31.1.1.12 | not-accessible | Indicates the BIP8 statistics. This table lists the various BIP8 statistics. | |
| hwPortBip8StatisticsEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.12.1 | not-accessible | Indicates the BIP8 statistics. This table lists the various BIP8 statistics. | |
| C64 hwPhysicalPortBip8StatisticsEB | 1.3.6.1.4.1.2011.5.25.31.1.1.12.1.1 | Counter64 | read-only | BIP8 Statistics: EB(Errored Block). |
| C64 hwPhysicalPortBip8StatisticsES | 1.3.6.1.4.1.2011.5.25.31.1.1.12.1.2 | Counter64 | read-only | BIP8 Statistics: ES(Errored Second). |
| C64 hwPhysicalPortBip8StatisticsSES | 1.3.6.1.4.1.2011.5.25.31.1.1.12.1.3 | Counter64 | read-only | BIP8 Statistics: SES(Severely Errored Second). |
| C64 hwPhysicalPortBip8StatisticsUAS | 1.3.6.1.4.1.2011.5.25.31.1.1.12.1.4 | Counter64 | read-only | BIP8 Statistics: UAS(Unavailable Errored Second). |
| C64 hwPhysicalPortBip8StatisticsBBE | 1.3.6.1.4.1.2011.5.25.31.1.1.12.1.5 | Counter64 | read-only | BIP8 Statistics: BBE(Background Block Error). |
| U32 hwPhysicalPortSpeed | 1.3.6.1.4.1.2011.5.25.31.1.1.12.1.6 | Unsigned32 | read-only | An estimate of the interface's current bandwidth in 1000000 bits per second. |
| hwStorageEntTable | 1.3.6.1.4.1.2011.5.25.31.1.1.13 | not-accessible | Indicates the Storage statistics | |
| hwStorageEntEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.13.1 | not-accessible | Indicates the Storage statistics. This table lists the Entity Storage statistics. | |
| I32 hwStorageEntIndex | 1.3.6.1.4.1.2011.5.25.31.1.1.13.1.1 | Integer32 | read-only | The Index of Storage statistics. |
| I32 hwStorageEntType | 1.3.6.1.4.1.2011.5.25.31.1.1.13.1.2 | Integer32 | read-only | The Type of Storage. |
| I32 hwStorageEntSpace | 1.3.6.1.4.1.2011.5.25.31.1.1.13.1.3 | Integer32 | read-only | The Size of Storage. |
| I32 hwStorageEntSpaceFree | 1.3.6.1.4.1.2011.5.25.31.1.1.13.1.4 | Integer32 | read-only | The Free Size of Storage. |
| STR hwStorageEntName | 1.3.6.1.4.1.2011.5.25.31.1.1.13.1.5 | SnmpAdminString | read-only | The Name of Storage. |
| STR hwStorageEntDescr | 1.3.6.1.4.1.2011.5.25.31.1.1.13.1.6 | SnmpAdminString | read-only | The Description of Storage. |
| hwSystemPowerTable | 1.3.6.1.4.1.2011.5.25.31.1.1.14 | not-accessible | System power infomation table. | |
| hwSystemPowerEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.14.1 | not-accessible | System power infomation entry. | |
| I32 hwSystemPowerDeviceID | 1.3.6.1.4.1.2011.5.25.31.1.1.14.1.1 | Integer32 | read-only | System power infomation device ID. |
| I32 hwSystemPowerTotalPower | 1.3.6.1.4.1.2011.5.25.31.1.1.14.1.2 | Integer32 | read-only | System power infomation total power. |
| I32 hwSystemPowerUsedPower | 1.3.6.1.4.1.2011.5.25.31.1.1.14.1.3 | Integer32 | read-only | System power infomation used power. |
| I32 hwSystemPowerRemainPower | 1.3.6.1.4.1.2011.5.25.31.1.1.14.1.4 | Integer32 | read-only | System power infomation remain power. |
| I32 hwSystemPowerReservedPower | 1.3.6.1.4.1.2011.5.25.31.1.1.14.1.5 | Integer32 | read-only | System power infomation reserved power. |
| hwBatteryInfoTable | 1.3.6.1.4.1.2011.5.25.31.1.1.15 | not-accessible | Description.Battery information table | |
| hwBatteryInfoEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.15.1 | not-accessible | Description.Battery information entry | |
| INT hwBatteryState | 1.3.6.1.4.1.2011.5.25.31.1.1.15.1.1 | INTEGER | read-only | Description.The state of lithium battery. |
| I32 hwBatteryTemperatureLow | 1.3.6.1.4.1.2011.5.25.31.1.1.15.1.2 | Integer32 | read-only | Description.The lowest temperature of lithium battery. |
| I32 hwBatteryTemperatureHigh | 1.3.6.1.4.1.2011.5.25.31.1.1.15.1.3 | Integer32 | read-only | Description.The highest temperature of lithium battery. |
| I32 hwBatteryRemainPercent | 1.3.6.1.4.1.2011.5.25.31.1.1.15.1.4 | Integer32 | read-only | Description. The remained electricity quantity percent of lithium battery,unit in minute. |
| I32 hwBatteryRemainTime | 1.3.6.1.4.1.2011.5.25.31.1.1.15.1.5 | Integer32 | read-only | Description. The remained time of lithium battery. |
| I32 hwBatteryElecTimes | 1.3.6.1.4.1.2011.5.25.31.1.1.15.1.6 | Integer32 | read-only | Description.The charge and discharge times of lithium battery. |
| I32 hwBatteryLifeThreshold | 1.3.6.1.4.1.2011.5.25.31.1.1.15.1.7 | Integer32 | read-write | Description.The warning threshold of lithium battery's lifetime.(unit in minute,the default value is 20) |
| hwGPSLocationInfo | 1.3.6.1.4.1.2011.5.25.31.1.1.16 | |||
| OCT hwGPSLongitude | 1.3.6.1.4.1.2011.5.25.31.1.1.16.1 | OCTET STRING | read-only | Description.The longitude of the device location. |
| OCT hwGPSLatitude | 1.3.6.1.4.1.2011.5.25.31.1.1.16.2 | OCTET STRING | read-only | Description.The latidude of the device location. |
| OCT hwGPSVelocity | 1.3.6.1.4.1.2011.5.25.31.1.1.16.3 | OCTET STRING | read-only | Description.The velocity of the device. |
| hwAdmPortTable | 1.3.6.1.4.1.2011.5.25.31.1.1.17 | not-accessible | The table of ADM(Add/Drop Multiplexer) port properties. | |
| hwAdmPortEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.17.1 | not-accessible | The entry of ADM(Add/Drop Multiplexer) port properties table. | |
| OCT hwAdmPortDescription | 1.3.6.1.4.1.2011.5.25.31.1.1.17.1.1 | OCTET STRING | read-write | The description of ADM(Add/Drop Multiplexer) port. |
| hwPwrStatusTable | 1.3.6.1.4.1.2011.5.25.31.1.1.18 | not-accessible | This table lists the status of powers. You can read the status of the powers on the device. | |
| hwPwrStatusEntry | 1.3.6.1.4.1.2011.5.25.31.1.1.18.1 | not-accessible | Defines an entry in the hwPwrStatusTable. | |
| I32 hwEntityPwrSlot | 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.1 | Integer32 | read-only | This object indicates the slot ID of a power. |
| I32 hwEntityPwrSn | 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.2 | Integer32 | read-only | This object indicates the serial number of the power in a certain slot. |
| INT hwEntityPwrReg | 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.3 | INTEGER | read-only | This object indicates whether the power is registered. |
| INT hwEntityPwrMode | 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.4 | INTEGER | read-only | This object indicates the mode of the power. |
| INT hwEntityPwrPresent | 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.5 | INTEGER | read-only | This object indicates the present information of the power. |
| INT hwEntityPwrState | 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.6 | INTEGER | read-only | This object indicates the state of the power. |
| I32 hwEntityPwrCurrent | 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.7 | Integer32 | read-only | This object indicates the current of the power. Unit: mA |
| I32 hwEntityPwrVoltage | 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.8 | Integer32 | read-only | This object indicates the voltage of the power. Unit: mV |
| OCT hwEntityPwrDesc | 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.9 | OCTET STRING | read-only | This object indicates the description of the power. |
| hwEntityPhysicalSpecTable | 1.3.6.1.4.1.2011.5.25.31.1.2 | |||
| I32 hwEntityPhysicalSpecRack | 1.3.6.1.4.1.2011.5.25.31.1.2.1 | Integer32 | read-only | The rack coefficient used for calculating the index of the physical entity. |
| I32 hwEntityPhysicalSpecFrame | 1.3.6.1.4.1.2011.5.25.31.1.2.2 | Integer32 | read-only | The frame coefficient used for calculating the index of the physical entity. |
| I32 hwEntityPhysicalSpecSlot | 1.3.6.1.4.1.2011.5.25.31.1.2.3 | Integer32 | read-only | The slot coefficient used for calculating the index of the physical entity. |
| I32 hwEntityPhysicalSpecBoard | 1.3.6.1.4.1.2011.5.25.31.1.2.4 | Integer32 | read-only | The board coefficient used for calculating the index of the physical entity. |
| I32 hwEntityPhysicalSpecSubSlot | 1.3.6.1.4.1.2011.5.25.31.1.2.5 | Integer32 | read-only | The sub slot coefficient used for calculating the index of the physical entity. |
| I32 hwEntityPhysicalSpecSubBoard | 1.3.6.1.4.1.2011.5.25.31.1.2.6 | Integer32 | read-only | The sub board coefficient used for calculating the index of the physical entity. |
| I32 hwEntityPhysicalSpecPort | 1.3.6.1.4.1.2011.5.25.31.1.2.7 | Integer32 | read-only | The port coefficient used for calculating the index of the physical entity. |
| I32 hwEntityPhysicalSpecEmu | 1.3.6.1.4.1.2011.5.25.31.1.2.8 | Integer32 | read-only | The EMU(Environment monitoring unit) coefficient used for calculating the index of the physical entity. |
| I32 hwEntityPhysicalSpecPowerframe | 1.3.6.1.4.1.2011.5.25.31.1.2.9 | Integer32 | read-only | The power frame coefficient used for calculating the index of the physical entity. |
| I32 hwEntityPhysicalSpecPowermodule | 1.3.6.1.4.1.2011.5.25.31.1.2.10 | Integer32 | read-only | The power module coefficient used for calculating the index of the physical entity. |
| I32 hwEntityPhysicalSpecBattery | 1.3.6.1.4.1.2011.5.25.31.1.2.11 | Integer32 | read-only | The battery coefficient used for calculating the index of the physical entity. |
| hwEntityExtTraps | 1.3.6.1.4.1.2011.5.25.31.2 | |||
| hwEntityExtTrapsPrefix | 1.3.6.1.4.1.2011.5.25.31.2.0 | |||
| NTF hwEntityExtTemperatureThresholdNotification | 1.3.6.1.4.1.2011.5.25.31.2.0.1 | The hwEntityEnvTemperatureThresholdNotification indicates the temperature have been exceed the threshold. In the condition, user should check the hardware and the environment of the entity, sometimes it happened because of the failture of air-condition. Anyway, the threshold should lower than the value that most service work fine. | ||
| NTF hwEntityExtVoltageLowThresholdNotification | 1.3.6.1.4.1.2011.5.25.31.2.0.2 | The hwEntityExtVoltageLowThresholdNotification indicates the voltage is lower than the threshold. This may decrease the usability of the entity. If the voltage is lower too much than the hardware needed, the entity will stop working. Anyway, the threshold should higher than the value that most service work fine. | ||
| NTF hwEntityExtVoltageHighThresholdNotification | 1.3.6.1.4.1.2011.5.25.31.2.0.3 | The hwEntityExtVoltageHighThresholdNotification indicates the voltage is higher than the threshold. This may decrease the usability of the entity. If the voltage is higher too much than the hardware needed, the entity may be destroyed by the high voltage. Anyway, the threshold should lower than the value that most service work fine. | ||
| NTF hwEntityExtCpuUsageThresholdNotfication | 1.3.6.1.4.1.2011.5.25.31.2.0.4 | The hwEntityExtCpuUsageThresholdNotfication indicates the entity is overload, and the service running in the entity will not get the performance it should because of CPU's performance. Anyway, the threshold should lower than the value that most service work fine. | ||
| NTF hwEntityExtMemUsageThresholdNotification | 1.3.6.1.4.1.2011.5.25.31.2.0.5 | The hwEntityExtMemUsageThresholdNotification indicates the entity is overload, and the service running in the entity will not get the performance it should because of lower memory. Anyway, the threshold should lower than the value that most service work fine. | ||
| NTF hwEntityExtOperEnabled | 1.3.6.1.4.1.2011.5.25.31.2.0.6 | The entity is operational. The entity this notification refers can be identified by extracting the entPhysicalIndex from one of the variable bindings. | ||
| NTF hwEntityExtOperDisabled | 1.3.6.1.4.1.2011.5.25.31.2.0.7 | The entity is operational. The entity this notification refers can be identified by extracting the entPhysicalIndex from one of the variable bindings. | ||
| NTF hwEntityExtMonitorBoardAbnormalNotification | 1.3.6.1.4.1.2011.5.25.31.2.0.8 | The monitor board turns normal to abnormal. | ||
| NTF hwEntityExtMonitorBoardNormalNotification | 1.3.6.1.4.1.2011.5.25.31.2.0.9 | The monitor board turns abnormal to normal. | ||
| NTF hwEntityExtMonitorPortAbnormalNotification | 1.3.6.1.4.1.2011.5.25.31.2.0.10 | The monitor port turns normal to abnormal. | ||
| NTF hwEntityExtMonitorPortNormalNotification | 1.3.6.1.4.1.2011.5.25.31.2.0.11 | The monitor port turns abnormal to normal. | ||
| NTF hwEntityExtCpuUsageLowThresholdNotfication | 1.3.6.1.4.1.2011.5.25.31.2.0.12 | The hwEntityExtCpuUsageThresholdNotfication indicates the entity is overload, and the service running in the entity will not get the performance it should because of CPU's performance. Anyway, the threshold should lower than the value that most service work fine. | ||
| hwEntityExtTrapObject | 1.3.6.1.4.1.2011.5.25.31.2.1 | |||
| OCT hwEntityExtTrapBaseSoftwareVersion | 1.3.6.1.4.1.2011.5.25.31.2.1.1 | OCTET STRING | accessible-for-notify | System bassic software version. |
| OCT hwEntityExtTrapBoardSoftwareVersion | 1.3.6.1.4.1.2011.5.25.31.2.1.2 | OCTET STRING | accessible-for-notify | Board software version compare to basic software version. |
| OCT hwPhysicalName | 1.3.6.1.4.1.2011.5.25.31.2.1.3 | OCTET STRING | read-only | The textual name of the physical entity. The value of this object should be the name of the component as assigned by the local device and should be suitable for use in commands entered at the device's `console'. This might be a text name, such as `console' or a simple component number (e.g., port or module number), such as `1', depending on the physical component naming syntax of the device. If there is no local name, or this object is otherwise not applicable, then this object contains a zero-length string. Note that the value of entPhysicalName for two physical entities will be the same in the event that the console interface does not distinguish between them, e.g., slot-1 and the card in slot-1. |
| hwEntityExtTrap | 1.3.6.1.4.1.2011.5.25.31.2.2 | |||
| NTF hwBoardSoftwareVersionIncompatible | 1.3.6.1.4.1.2011.5.25.31.2.2.1 | Board software version incompatible with basic software version. | ||
| NTF hwBoardSplitPorts | 1.3.6.1.4.1.2011.5.25.31.2.2.2 | When the split ports exist on the board, send a SNMP trap to network manager. | ||
| hwDevicePowerInfoObjects | 1.3.6.1.4.1.2011.5.25.31.3 | |||
| I32 hwDevicePowerInfoTotalPower | 1.3.6.1.4.1.2011.5.25.31.3.1 | Integer32 | read-only | Device total power. |
| I32 hwDevicePowerInfoUsedPower | 1.3.6.1.4.1.2011.5.25.31.3.2 | Integer32 | read-only | Device used power. |
| hwEntityExtConformance | 1.3.6.1.4.1.2011.5.25.31.4 | |||
| hwEntityExtCompliances | 1.3.6.1.4.1.2011.5.25.31.4.1 | |||
| hwEntityExtCompliance | 1.3.6.1.4.1.2011.5.25.31.4.1.1 | The compliance statement for systems supporting the HUAWEI Entity extent MIB. | ||
| hwEntityExtGroups | 1.3.6.1.4.1.2011.5.25.31.4.2 | |||
| hwEntityExtGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.1 | Standard HUAWEI Entity Extent group. | ||
| hwEntityExtNotificationGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.2 | Standard HUAWEI Entity Extent Notification group. | ||
| hwRUModuleInfoGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.3 | Standard HUAWEI Entity Extent group. | ||
| hwEntityExtOldObjectsGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.4 | Group for old objects that may be obsoleted. | ||
| hwOpticalModuleInfoGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.5 | Collection of objects that display the fiber module working information. | ||
| hwMonitorInputGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.6 | Standard HUAWEI Entity Extent group. | ||
| hwMonitorOutputGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.7 | Standard HUAWEI Entity Extent group. | ||
| hwEntPowerUsedInfoGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.8 | Collection of objects that display the power informations of entity. | ||
| hwDevicePowerInfoGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.9 | Collection of objects that display the power informations of device. | ||
| hwVirtualCableTestGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.10 | Collection of objects that display the status of cable. | ||
| hwTemperatureThresholdGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.11 | Temperature threshold group. | ||
| hwVoltageInfoGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.12 | Voltage info group. | ||
| hwFanStatusGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.13 | fan state group. | ||
| hwPnpGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.14 | Pnp group. | ||
| hwSystemGlobalGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.15 | System global group. | ||
| hwHeartbeatGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.16 | Heart beat group. | ||
| hwPortBip8StatisticsObjectGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.17 | The BIP8 statistics group. | ||
| hwPredisposeGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.18 | Pnp group. | ||
| hwSystemPowerGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.19 | Description. | ||
| hwX86BoardGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.20 | X86 group. | ||
| hwPwrStatusGroup | 1.3.6.1.4.1.2011.5.25.31.4.2.21 | pwr state group. | ||
| hwPnpObjects | 1.3.6.1.4.1.2011.5.25.31.5 | |||
| hwPnpInfo | 1.3.6.1.4.1.2011.5.25.31.5.1 | |||
| STR hwHardwareCapaSequenceNo | 1.3.6.1.4.1.2011.5.25.31.5.1.1 | SnmpAdminString | read-only | This object indicates the sequence number of the 'hardware capability file'.The value consists of the file version number and CRC code. |
| STR hwAlarmPnPSequenceNo | 1.3.6.1.4.1.2011.5.25.31.5.1.2 | SnmpAdminString | read-only | This object indicates the sequence number of the 'alarm capability file'.The value consists of the file version number and CRC code. |
| hwPnpTraps | 1.3.6.1.4.1.2011.5.25.31.5.2 | |||
| NTF hwHardwareCapaChangeNotification | 1.3.6.1.4.1.2011.5.25.31.5.2.1 | This object indicates the change of the 'hardware capability file'. An alarm is generated if the sequence number of the 'hardware capability file' in the current startup file is different from that in the last startup file. | ||
| NTF hwAlarmPnPChangeNotification | 1.3.6.1.4.1.2011.5.25.31.5.2.2 | This object indicates the change of the 'alarm capability file'. An alarm is generated if the sequence number of the 'alarm capability file' in the current startup file is different from that in the last startup file. | ||
| hwPnpOperateTable | 1.3.6.1.4.1.2011.5.25.31.5.3 | not-accessible | This table describes the hardware functions. Using this table, you can obtain the specified 'hardware description file' or 'hardware capability file'. | |
| hwPnpOperateEntry | 1.3.6.1.4.1.2011.5.25.31.5.3.1 | not-accessible | ||
| I32 hwFileGeneIndex | 1.3.6.1.4.1.2011.5.25.31.5.3.1.1 | Integer32 | not-accessible | The value of this object identifies the operation index, which can be specified by the user. The value ranges from 1 to 2147483647. |
| INT hwFileGeneOperState | 1.3.6.1.4.1.2011.5.25.31.5.3.1.2 | INTEGER | read-only | The value of this object identifies the operation status. opInProgress(1): The operation is ongoing. opSuccess(2): The operation succeeds. opGetFileError(3): Obtaining the file fails. opInvalidDestName(4): The specified storage path is invalid. opNoFlashSpace(5): The space in the flash memory is insufficient. opWriteFileError(6): Writing the file fails. opDestoryError(7): Deleting the file fails. |
| INT hwFileGeneResourceType | 1.3.6.1.4.1.2011.5.25.31.5.3.1.3 | INTEGER | read-write | This object indicates the type of the file to be obtained. pnpcard(1): board description file pnpcard(2): subcard description file pnphardcapability(3): hardware capability file pnpPreDisposeCapability(4): predispose capability file pnpframe(5):frame description file pnpdevtype(6):device description file pnpalarm(7):alarm description file |
| STR hwFileGeneResourceID | 1.3.6.1.4.1.2011.5.25.31.5.3.1.4 | SnmpAdminString | read-write | This object indicates the ID of the 'hardware capability file' to be obtained. |
| STR hwFileGeneDestinationFile | 1.3.6.1.4.1.2011.5.25.31.5.3.1.5 | SnmpAdminString | read-write | This object indicates the target path storing the file, which does not need to be specified. |
| ROW hwFileGeneRowStatus | 1.3.6.1.4.1.2011.5.25.31.5.3.1.6 | RowStatus | read-create | This object indicates the row status. active(1) notInService(2) notReady(3) createAndGo(4) createAndWait(5) destroy(6) |
| hwSystemGlobalObjects | 1.3.6.1.4.1.2011.5.25.31.6 | |||
| OCT hwEntitySystemNetID | 1.3.6.1.4.1.2011.5.25.31.6.1 | OCTET STRING | read-write | Network element ID. |
| STR hwEntitySoftwareName | 1.3.6.1.4.1.2011.5.25.31.6.2 | SnmpAdminString | read-only | System software name. |
| STR hwEntitySoftwareVersion | 1.3.6.1.4.1.2011.5.25.31.6.3 | SnmpAdminString | read-only | Software version number. |
| STR hwEntitySoftwareVendor | 1.3.6.1.4.1.2011.5.25.31.6.4 | SnmpAdminString | read-only | Software vendor. |
| STR hwEntitySystemModel | 1.3.6.1.4.1.2011.5.25.31.6.5 | SnmpAdminString | read-only | Device model. |
| STR hwEntitySystemTime | 1.3.6.1.4.1.2011.5.25.31.6.6 | SnmpAdminString | read-write | System time displayed on the device. |
| STR hwEntitySystemMacAddress | 1.3.6.1.4.1.2011.5.25.31.6.7 | SnmpAdminString | read-only | MAC address of the device. |
| INT hwEntitySystemReset | 1.3.6.1.4.1.2011.5.25.31.6.8 | INTEGER | read-write | System reset. |
| I32 hwEntitySystemHealthInterval | 1.3.6.1.4.1.2011.5.25.31.6.9 | Integer32 | read-write | Statistical interval for average CPU and memory usage, in seconds (By default, the value is 300) . |
| I32 hwEntitySystemNEId | 1.3.6.1.4.1.2011.5.25.31.6.10 | Integer32 | read-write | Systme NEId. |
| STR hwEntitySystemServiceType | 1.3.6.1.4.1.2011.5.25.31.6.11 | SnmpAdminString | read-only | System service type. |
| hwHeartbeatObjects | 1.3.6.1.4.1.2011.5.25.31.7 | |||
| hwHeartbeatConfig | 1.3.6.1.4.1.2011.5.25.31.7.1 | |||
| INT hwEntityHeartbeatOnOff | 1.3.6.1.4.1.2011.5.25.31.7.1.1 | INTEGER | read-write | Whether Heartbeat sending periodically enabled. |
| I32 hwEntityHeartbeatPeriod | 1.3.6.1.4.1.2011.5.25.31.7.1.2 | Integer32 | read-write | Heartbeat sending period detected in the trap reporting channel, with the minimum value of 60 seconds. |
| hwHeartbeatTrapPrefix | 1.3.6.1.4.1.2011.5.25.31.7.2 | |||
| NTF hwEntityHeartbeatTrap | 1.3.6.1.4.1.2011.5.25.31.7.2.1 | Heartbeat trap. | ||
| hwPreDisposeObjects | 1.3.6.1.4.1.2011.5.25.31.8 | |||
| hwPreDisposeInfo | 1.3.6.1.4.1.2011.5.25.31.8.1 | |||
| STR hwPreDisposeSequenceNo | 1.3.6.1.4.1.2011.5.25.31.8.1.1 | SnmpAdminString | read-only | This object indicates the sequence number of the 'predispose capability file'.The value consists of the file version number and CRC code. |
| hwPreDisposedTraps | 1.3.6.1.4.1.2011.5.25.31.8.2 | |||
| NTF hwInsertDiffFromPreDisposed | 1.3.6.1.4.1.2011.5.25.31.8.2.1 | This object indicates the type of the inserted entity is different from that of pre-disposed entity on the slot. | ||
| NTF hwPreDisposedChangeNotification | 1.3.6.1.4.1.2011.5.25.31.8.2.2 | This object indicates the change of the 'predispose capability file'. An alarm is generated if the sequence number of the 'predispose capability file' in the current startup file is different from that in the last startup file. | ||
| hwPreDisposeConfigTable | 1.3.6.1.4.1.2011.5.25.31.8.3 | not-accessible | Table of predisposing boards or flexible subcards. | |
| hwPreDisposeConfigEntry | 1.3.6.1.4.1.2011.5.25.31.8.3.1 | not-accessible | Entry of the table to predispose boards or flexible subcards. | |
| I32 hwDisposeSlot | 1.3.6.1.4.1.2011.5.25.31.8.3.1.1 | Integer32 | read-write | This object indicates the slot ID of predisposed board. |
| I32 hwDisposeCardId | 1.3.6.1.4.1.2011.5.25.31.8.3.1.2 | Integer32 | read-write | This object indicates the card ID of predisposed subcard. |
| OCT hwDisposeSbom | 1.3.6.1.4.1.2011.5.25.31.8.3.1.3 | OCTET STRING | read-write | This object indicates the sbom information of predisposed board or subcard. |
| ROW hwDisposeRowStatus | 1.3.6.1.4.1.2011.5.25.31.8.3.1.4 | RowStatus | read-create | This object indicates the row status when config predispose. active(1) notInService(2) notReady(3) createAndGo(4) createAndWait(5) destroy(6) |
| INT hwDisposeOperState | 1.3.6.1.4.1.2011.5.25.31.8.3.1.5 | INTEGER | read-only | The value of this object identifies the operation status. opSuccess(1): The operation succeeds. opInProgress(2): The operation is ongoing. opDevNotSupportPredispose(3): The device does not support predispose. opCardNotSupportPredispose(4): The type of card or subcard is not supported to be predisposed on this device. opAlreadyPredispose(5): The slot or subslot has already been predisposed. opCardConflict(6): The slot or subslot to be predisposed conflict with others. opDevOperationError(7): Other error occurs on the device. |
| hwPreDisposeEntInfoTable | 1.3.6.1.4.1.2011.5.25.31.8.4 | not-accessible | This table is used to get the information of predisposed entitys. | |
| hwPreDisposeEntInfoEntry | 1.3.6.1.4.1.2011.5.25.31.8.4.1 | not-accessible | Entry of the table to get the information of predisposed entitys. | |
| PHY hwDisposeEntPhysicalIndex | 1.3.6.1.4.1.2011.5.25.31.8.4.1.1 | PhysicalIndex | accessible-for-notify | The index for this entry. |
| STR hwDisposeEntPhysicalDescr | 1.3.6.1.4.1.2011.5.25.31.8.4.1.2 | SnmpAdminString | read-only | A textual description of predisposed physical entity.This object should contain a string which identifies the manufacturer's name for the physical entity. |
| OID hwDisposeEntPhysicalVendorType | 1.3.6.1.4.1.2011.5.25.31.8.4.1.3 | AutonomousType | read-only | An indication of the vendor-specific hardware type of the predisposed physical entity. |
| I32 hwDisposeEntPhysicalContainedIn | 1.3.6.1.4.1.2011.5.25.31.8.4.1.4 | Integer32 | read-only | The value of 'entPhysicalContainedIn' for the predisposed physical entity. |
| PHY hwDisposeEntPhysicalClass | 1.3.6.1.4.1.2011.5.25.31.8.4.1.5 | PhysicalClass | read-only | An indication of the general hardware type of the predisposed physical entity. |
| I32 hwDisposeEntPhysicalParentRelPos | 1.3.6.1.4.1.2011.5.25.31.8.4.1.6 | Integer32 | read-only | An indication of the relative position of this 'child' component among all its 'sibling' components. |
| STR hwDisposeEntPhysicalName | 1.3.6.1.4.1.2011.5.25.31.8.4.1.7 | SnmpAdminString | read-only | The textual name of the predisposed physical entity. |
| hwOSPUnifyManageObjects | 1.3.6.1.4.1.2011.5.25.31.9 | |||
| hwEntityExtOSPTrapsPrefix | 1.3.6.1.4.1.2011.5.25.31.9.1 | |||
| NTF hwEntityExtUnconnected | 1.3.6.1.4.1.2011.5.25.31.9.1.1 | Board become unconnected for some reason. | ||
| NTF hwEntityExtUnconnectedResume | 1.3.6.1.4.1.2011.5.25.31.9.1.2 | Board resume from unconnected |
RFC description
Huawei extended entity MIB for device management including hardware, optical modules, and entity status.
Start monitoring Huawei router or switch (extended CPU/memory/entity/optics inventory) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.