| OID symbolic | OID numeric | Type | Access | Description |
| C32 aISS15MinBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.26 | Counter32 | read-only | This counter counts the number of
AIS Severely Errored Seconds in the last 15 minutes
encountered by the interface. |
| I32 aISS15MinThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.25 | Integer32 | read-write | Alarm Indication Signal Second - is a count of one-second
intervals containing one or more incoming AIS.
The value set in this object determines the value
which when exceeded in a 15 minute window causes
a statistical alarm to be declared. |
| C32 aISS24HrBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.27 | Counter32 | read-only | This counter counts the number of
AIS Severely Errored Seconds in the last 24 hours
encountered by the interface. |
| I32 aISS24HrThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.26 | Integer32 | read-write | Alarm Indication Signal Second - is a count of one-second
intervals containing one or more incoming AIS.
The value set in this object determines the value
which when exceeded in a sliding 24 hour window causes
a statistical alarm to be declared. The threshold is
checked every 15 minutes for the preceding 24 hour interval |
| C32 aISSCurrent | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.25 | Counter32 | read-only | This counter counts the number of
AIS Severely Errored Seconds
encountered by the interface. |
| INT alarmClrButton | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.32 | INTEGER | read-write | This variable is used to clear all the alarms
for the line.
1 = No action
2 = Clear alarm |
| I32 almCnfLineNum | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.1 | Integer32 | read-only | This object identifies the DS1/E1 interface.
The value for this object must be same as the
value of lineNum from dsx1CnfGrpTable. |
| I32 almLineNum | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.1 | Integer32 | read-only | This object identifies the DS1/E1 interface.
The value for this object must be same as the
value of lineNum from dsx1CnfGrpTable. |
| INT bERTResultClrButton | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.15 | INTEGER | read-write | This clears the result of the BERT. |
| ciscoMgx82xxDsx1MIB | 1.3.6.1.4.1.351.150.58 | | | The MIB module to configure DS1/E1 interface
objects. This mib also contains the alarm
configuration of DS1/E1 interfaces. This mib
is supported in T1/E1 service modules. |
| cmDsx1AlarmConfGroup | 1.3.6.1.4.1.351.150.58.2.1.4 | | | The collection of objects used for
DS1/E1 Alarm threshold configuration. |
| cmDsx1AlarmGroup | 1.3.6.1.4.1.351.150.58.2.1.5 | | | The collection of objects used for
DS1/E1 Alarm configuration. |
| cmDsx1Compliance | 1.3.6.1.4.1.351.150.58.2.2.1 | | | The compliance statement for objects related
to DS1/E1 mib. |
| cmDsx1ConfGroup | 1.3.6.1.4.1.351.150.58.2.1.2 | | | The collection of objects used for
DS1/E1 interface configuration. |
| cmDsx1CountGroup | 1.3.6.1.4.1.351.150.58.2.1.3 | | | The collection of objects related to
DS1/E1 statistics. |
| cmDsx1GeneralGroup | 1.3.6.1.4.1.351.150.58.2.1.1 | | | The collection of objects used for
DS1/E1 interfaces. |
| cmDsx1MIBCompliances | 1.3.6.1.4.1.351.150.58.2.2 | | | |
| cmDsx1MIBConformance | 1.3.6.1.4.1.351.150.58.2 | | | |
| cmDsx1MIBGroups | 1.3.6.1.4.1.351.150.58.2.1 | | | |
| I32 cntLineNum | 1.3.6.1.4.1.351.110.4.3.1.4.1.1.1 | Integer32 | read-only | This object identifies the DS1/E1 interface.
The value for this object must be same as the
value of lineNum from dsx1CnfGrpTable. |
| INT counterClearButton | 1.3.6.1.4.1.351.110.4.3.1.4.1.1.6 | INTEGER | read-write | This variable is used to clear all the counters. |
| C32 cRC15MinBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.14 | Counter32 | read-only | This counter counts the number of
P Bit code violations in the last 15 minutes
encountered by the interface. |
| I32 cRC15MinThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.17 | Integer32 | read-write | The value set in this object determines the value
which when exceeded in a 15 minute window causes
a statistical alarm to be declared. |
| C32 cRC24HrBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.15 | Counter32 | read-only | This counter counts the number of
P Bit code violations in the last 24 hours
encountered by the interface. |
| I32 cRC24HrThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.18 | Integer32 | read-write | The value set in this object determines the value
which when exceeded in a sliding 24 hour window causes
a statistical alarm to be declared. The threshold is
checked every 15 minutes for the preceding 24 hour interval |
| C32 cRCCurrent | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.13 | Counter32 | read-only | This counter counts the number of
P Bit code violations
encountered by the interface. |
| C32 cRCES15MinBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.17 | Counter32 | read-only | This counter counts the number of
PCV Errored Seconds in the last 15 minutes
encountered by the interface. |
| I32 cRCES15MinThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.19 | Integer32 | read-write | The value set in this object determines the value
which when exceeded in a 15 minute window causes
a statistical alarm to be declared. |
| C32 cRCES24HrBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.18 | Counter32 | read-only | This counter counts the number of
PCV Errored Seconds in the last 24 hours
encountered by the interface. |
| I32 cRCES24HrThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.20 | Integer32 | read-write | The value set in this object determines the value
which when exceeded in a sliding 24 hour window causes
a statistical alarm to be declared. The threshold is
checked every 15 minutes for the preceding 24 hour interval |
| C32 cRCESCurrent | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.16 | Counter32 | read-only | This counter counts the number of
PCV Errored Seconds
encountered by the interface. |
| C32 cRCSES15MinBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.20 | Counter32 | read-only | This counter counts the number of
PCV Severely Errored Seconds in the last 15 minutes
encountered by the interface. |
| I32 cRCSES15MinThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.21 | Integer32 | read-write | The value set in this object determines the value
which when exceeded in a 15 minute window causes
a statistical alarm to be declared. |
| C32 cRCSES24HrBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.21 | Counter32 | read-only | This counter counts the number of
PCV Severely Errored Seconds in the last 24 hours
encountered by the interface. |
| I32 cRCSES24HrThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.22 | Integer32 | read-write | The value set in this object determines the value
when exceeded in a sliding 24 hour window causes
a statistical alarm to be declared. The threshold is
checked every 15 minutes for the preceding 24 hour interval |
| C32 cRCSESCurrent | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.19 | Counter32 | read-only | This counter counts the number of
P Bit code violations Severely Errored Seconds
encountered by the interface. |
| dsx1AlmCnfGrp | 1.3.6.1.4.1.351.110.4.3.1.2 | | | |
| dsx1AlmCnfGrpEntry | 1.3.6.1.4.1.351.110.4.3.1.2.1.1 | | not-accessible | An entry in the DS1 Alarm Configuration table. |
| dsx1AlmCnfGrpTable | 1.3.6.1.4.1.351.110.4.3.1.2.1 | | not-accessible | The DS1 interface alarm configuration table. |
| dsx1AlmGrp | 1.3.6.1.4.1.351.110.4.3.1.3 | | | |
| dsx1AlmGrpEntry | 1.3.6.1.4.1.351.110.4.3.1.3.1.1 | | not-accessible | An entry in the DS1 Alarm table. Each entry
represents the current, 15 minute and 24 Hour bucket
intervals for different performance parameters. |
| dsx1AlmGrpTable | 1.3.6.1.4.1.351.110.4.3.1.3.1 | | not-accessible | The DS1 interface alarm configuration table. |
| dsx1CnfGrp | 1.3.6.1.4.1.351.110.4.3.1.1 | | | |
| dsx1CnfGrpEntry | 1.3.6.1.4.1.351.110.4.3.1.1.1.1 | | not-accessible | An entry in the DS1 Configuration table. |
| dsx1CnfGrpTable | 1.3.6.1.4.1.351.110.4.3.1.1.1 | | not-accessible | The DS1/E1 Configuration table. The table size is
given by the value of lineNumofValidEntries |
| dsx1CntGrp | 1.3.6.1.4.1.351.110.4.3.1.4 | | | |
| dsx1CntGrpEntry | 1.3.6.1.4.1.351.110.4.3.1.4.1.1 | | not-accessible | An entry in the DS1 counter table. |
| dsx1CntGrpTable | 1.3.6.1.4.1.351.110.4.3.1.4.1 | | not-accessible | The DS1 Counter table. This table contains
statistics since the system was up or last
re-initialization. |
| I32 fEAlarmDownCount | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.8 | Integer32 | read-write | This parameter specifies the integration counter,
the Far-End alarms are AIS and YEL. Default value
is 1 and update counter every 10 ms to reach 0.
This is the down counter. |
| I32 fEAlarmThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.9 | Integer32 | read-write | The value set in this object determines the value
to declare Far-End alarm. A count of 1500 gives 2.5
secs to declare LOS with an up count value of 6. |
| I32 fEAlarmUpCount | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.7 | Integer32 | read-write | This parameter specifies the integration counter,
the Far-End alarms are AIS and YEL. Default value
is 6 and update counter 10 ms to reach the
threshold set in threshold object.
This is the up counter. |
| C32 lCV15MinBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.5 | Counter32 | read-only | The counter associated with the number of
Line code violations in the last 15 minute period
encountered by the interface. |
| I32 lCV15MinThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.11 | Integer32 | read-write | Code Violation - is the occurrence of a received CRC-6
code that is not identical to the corresponding locally.
calculated code. The value set in this object determines
the value which when exceeded in a 15 minute window causes
a statistical alarm to be declared. |
| C32 lCV24HrBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.6 | Counter32 | read-only | The counter associated with the number of
Line code violations in the last 24 hour period
encountered by the interface. |
| I32 lCV24HrThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.12 | Integer32 | read-write | Code Violation - is the occurence of a received CRC-6
code that is not identical to the corresponding locally.
The value set in this object determines the value
which when exceeded in a sliding 24 hour window causes
a statistical alarm to be declared. The threshold is
checked every 15 minutes for the preceding 24 hour interval |
| C32 lCVCurrent | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.4 | Counter32 | read-only | This counter counts the number of
Line code violations encountered by the interface. |
| C32 lES15MinBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.8 | Counter32 | read-only | This counter counts the number of
Line code violations Errored Seconds in the last 15 minutes
encountered by the interface. |
| I32 lES15MinThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.13 | Integer32 | read-write | Errored Second - is any second with at least one
code violation. The value set in this object determines
the value which when exceeded in a 15 minute window causes
a statistical alarm to be declared. |
| C32 lES24HrBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.9 | Counter32 | read-only | This counter counts the number of
Line code violations Errored Seconds in the last 24 hours
encountered by the interface. |
| I32 lES24HrThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.14 | Integer32 | read-write | Errored Second - is any second with at least one
code violation. The value set in this object determines
the value which when exceeded in a sliding 24 hour window
causes a statistical alarm to be declared. The threshold is
checked every 15 minutes for the preceding 24 hour interval |
| C32 lESCurrent | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.7 | Counter32 | read-only | This counter counts the number of
Line code violations Errored Seconds
encountered by the interface. |
| I32 lineAlarmState | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.2 | Integer32 | read-only | This variable is a bitmap of the DSX1 Line Alarms.
A value of zero indicates no alarms.
Itemized below are the individual bits:
BitPosition Alarm
----------- -----
0 Receiving RAI
1 Transmitting RAI
2 Receiving AIS
3 Transmitting AIS
4 Receiving OOF
5 Receiving LOS
6 Near End Local Loopback in effect
7 Near End Remote Loopback in effect
8 Near End Remote Payload Loopback
9 Receiving CRC MF OOF (E1)
10 Receiving Sig MF OOF (E1)
11 Receiving MF RAI (E1)
12 Receiving MF AIS (E1)
13 BERT in effect
14 Far End Remote Loopback in effect
15 Detected Near End Remote Loopback in
effect |
| INT lineBERTEnable | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.12 | INTEGER | read-write | This variable enables Bit Error Rate Testing(BERT). |
| INT lineBERTPattern | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.13 | INTEGER | read-write | This variable determines BERT pattern to transmit |
| INT lineBERTResult | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.14 | INTEGER | read-write | This shows the result of the BERT. |
| INT lineCoding | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.5 | INTEGER | read-write | This variable describes the variety of Zero
Code Suppression used on the link, which in
turn affects a number of its characteristics.
dsx1JBZS(1): refers the Jammed Bit Zero suppression
in which the AT&T specification of at
least one pulse every 8 bit periods is
literally implemented by forcing a pulse
in bit 8 of each channel. Thus, only seven
bits per chan- nel, or 1.344 Mbps, is available
for data.
dsx1B8ZS(2): refers to the use of a specified pattern
of normal bits and bipolar violations
which are used to replace a sequence of eight
zero bits.
E1 links, with or without CRC, use dsx1HDB3 or
dsx1AMI.
dsx1AMI(4): refers to a mode wherein no zero code
suppression is present and the line encoding
does not solve the problem directly. In this
application, the higher layer must provide data
which meets or exceeds the pulse density
requirements, such as inverting HDLC data.
The default value for T1 is 'dsx1JBZS' and for E1
is 'dsx1HDB3'.
This field is not applicable for FRSM-VHS cards
and is set to notUsed(5). |
| INT lineConnectorType | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.2 | INTEGER | read-write | This variable indicates the connector as well
as the backcard type. 1 = T1; 2 = E1.
This field is set to unused(4) for FRSM-VHS cards. |
| INT lineEnable | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.3 | INTEGER | read-write | This variable disables, enables or modifies a line
1 - disable
2 - enable
3 - modify
In FRSM-2CT3, if the DS3 line is enabled, then the DS1
channels for that line will all be automatically enabled.
No independent enable/disable is allowed for each of the
28 DS1 lines in FRSM-2CT3. |
| INT lineLength | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.6 | INTEGER | read-write | This is not a standard RFC 1407 DS1 variable, it is
specific to BASIS implementation. It specifies the line length:
1 - 0 to 110 ft (T1 line only)
2 - 110 to 220 ft (T1 line only)
3 - 220 to 330 ft (T1 line only)
4 - 330 to 440 ft (T1 line only)
5 - 440 to 550 ft (T1 line only)
6 - 550 to 660 ft (T1 line only)
7 - greater than 660 ft (T1 line only)
8 - 75 ohms (E1 line only (BNC))
9 - 120 ohms (E1 line only (DB-15))
The default value for T1 is 1, for E1, if the connector
type is DB15 then the default is 9, if BNC, it's 8.
For FRSM-2CT3, the line length of DS1 has no meaning
as there are no physical DS1 lines. So, for this
card, the value is set to notRequired (16). |
| INT lineLoopbackCodeDetection | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.11 | INTEGER | read-write | Enable detection of line Loopback Codes |
| INT lineLoopbackCommand | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.8 | INTEGER | read-write | This variable represents the loopback confi-
guration of the DS1 interface. Agents support-
ing read/write access should return badValue in
response to a requested loopback state that the
interface does not support. The values mean:
dsx1NoLoop
Not in the loopback state. A device that
is not capable of performing a loopback on
the interface shall always return this as
it's value.
dsx1RemoteLoop
The received signal at this interface is
looped through the device. Typically the
received signal is looped back for
retransmission after it has passed through
the device's framing function.
dsx1LocalLoop
The local data is looped back
dsx1PayloadLoop
This will loop only the payload and not
framing/sync bit. |
| I32 lineNum | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.1 | Integer32 | read-only | This object is the identifier of a DS1/E1
Interface on a managed device. If there is an
ifEntry that is directly associated with this
and only this DS1/E1 interface, it should have
the same value as ifIndex. Otherwise, number
the ds1LineIndices with an unique identifier
following the rules of choosing a number that
is greater than ifNumber and numbering the
inside interfaces (e.g., equipment side) with
even numbers and outside interfaces (e.g,
network side) with odd numbers.
The supported ranges depend upon the type of
the card(4 port/8 port etc):
For 4 port card : 1 - 4
For 8 port card : 1 - 8
For 2 Port Channelized card : 56 (28*2). |
| I32 lineNumofValidEntries | 1.3.6.1.4.1.351.110.4.3.1.1.2 | Integer32 | read-only | The number of DS1 configuration entries (regardless
of their current configuration) in the dsx1CnfGrpTable. |
| INT lineSendCode | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.9 | INTEGER | read-write | This variable indicates what type of code is
being sent across the DS1 interface by the dev-
ice. The values mean:
dsx1SendNoCode
sending looped or normal data
dsx1SendLineCode
sending a request for a line loopback
dsx1SendPayloadCode
sending a request for a payload loopback
dsx1SendResetCode
sending a loopback termination request |
| I32 lineStatisticalAlarmState | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.3 | Integer32 | read-only | This variable is a bitmap of the DSX1 Line Statistical
Alarms. A value of zero indicates no alarms.
Itemized below are the individual alarm bits:
BitPosition Alarm
----------- -----
0 LCV 15 minute threshold exceeded
1 LCV 24 hour threshold exceeded
2 LES 15 minute threshold exceeded
3 LES 24 hour threshold exceeded
4 LSES 15 minute threshold exceeded
5 LSES 24 hour threshold exceeded
6 CRC 15 minute threshold exceeded
7 CRC 24 hour threshold exceeded
8 CRCES 15 minute threshold exceeded
9 CRCES 24 hour threshold exceeded
10 CRCSES 15 minute threshold exceeded
11 CRCSES 24 hour threshold exceeded
12 SEFS 15 minute threshold exceeded
13 SEFS 24 hour threshold exceeded
14 AISS 15 minute threshold exceeded
15 AISS 24 hour threshold exceeded
16 UAS 15 minute threshold exceeded
17 UAS 24 hour threshold exceeded. |
| INT lineType | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.4 | INTEGER | read-write | This variable indicates the variety of DS1
Line implementing this circuit. The type of
circuit affects the number of bits per second
that the circuit can reasonably carry, as well
as the interpretation of the usage and error statistics.
The values, in sequence, describe:
TITLE: SPECIFICATION:
dsx1ESF Extended SuperFrame DS1
dsx1D4 AT&T D4 format DS1
dsx1E1 CCITT Recommendation G.704
(Table 4a)
dsx1E1-CRC CCITT Recommendation G.704
(Table 4b)
dsxE1-MF G.704 (Table 4a) with TS16
multiframing enabled
dsx1E1-CRC-MF G.704 (Table 4b) with TS16
multiframing enabled
dsx1E1clearchannel E1 clear channel, all DS0s can be used
dsx1E1Q50 G.704 (table 14) In TS16 bits 5,7,8 will be
set to 100 for all other cases bits 5,7,8 will
have a value of 111.
dsx1E1Q50CRC same as dsx1E1Q50 but with CRC.
NOTE: All E1, E1-CRC, E1-MF or E1-CRC-MF are using DS0
on slot 1 for signaling and E1-MF or E1-CRC-MF use DS0
on slot 17 for synchronization.
(Slot 1 and 16 is based on index 1 to 32 DS0)
All DS0s can be used for any port when lineType is
dsx1E1clearchannel.
On a CESM card, only 'dsx1E1clearchannel' option is supported.
When the lineType is dsx1E1Q50 the bits 5,7,8 of TS16
of frame zero will be forced to 100 else it will be 111.
The default value for T1 is 'dsx1ESF' and for E1
is 'dsx1E1CCS'. |
| I32 lineUsedTimeslotsBitMap | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.10 | Integer32 | read-only | Bit map of used DS0 for this line. |
| INT lineXmtClockSource | 1.3.6.1.4.1.351.110.4.3.1.1.1.1.7 | INTEGER | read-write | The source of Transmit Clock.
loopTiming(1): indicates that the recovered
receive clock is used as the
transmit clock.
localTiming(2): indicates that a local clock
source is used. |
| C32 lSES15MinBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.11 | Counter32 | read-only | This counter counts the number of
LCV Severely Errored Seconds in the last 15 minutes
encountered by the interface. |
| I32 lSES15MinThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.15 | Integer32 | read-write | Severely Errored Second - is any second with 15 or more
code violations. The value set in this object determines
the value which when exceeded in a 15 minute window causes
a statistical alarm to be declared. |
| C32 lSES24HrBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.12 | Counter32 | read-only | This counter counts the number of
LCV Severely Errored Seconds in the last 24 hours
encountered by the interface. |
| I32 lSES24HrThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.16 | Integer32 | read-write | Severely Errored Second - is any second with 15 or more
code violations. The value set in this object determines
the value which when exceeded in a sliding 24 hour window causes
a statistical alarm to be declared. The threshold is
checked every 15 minutes for the preceding 24 hour interval |
| C32 lSESCurrent | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.10 | Counter32 | read-only | This counter counts the number of
Line code violations Severely Errored Seconds
encountered by the interface. |
| I32 nEAlarmDownCount | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.5 | Integer32 | read-write | This parameter specifies the integration counter,
the Near-End alarms are LOS and LOF. Default value
is 1 and update counter every 10 ms to reach 0.
This is the down counter. |
| I32 nEAlarmThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.6 | Integer32 | read-write | The value set in this object determines the value
to declare Near-End alarm. A count of 1500 gives
2.5 sec to declare LOS with an up count value of
6. |
| I32 nEAlarmUpCount | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.4 | Integer32 | read-write | This parameter specifies the integration counter,
the local alarms are LOS and LOF. Default value
is 6 and update counter every 10 ms to reach the
threshold set in threshold object.
This is the up counter. |
| I32 percentEFS | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.31 | Integer32 | read-only | This counter counts the %LCV
Error Free Seconds. |
| INT rAISeverity | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.3 | INTEGER | read-write | This variable is used to setup the severity of RAI
alarm. So when LOS alarm is detected the card, an
alarm with appropriate severity status will be sent. |
| C32 rcvFECount | 1.3.6.1.4.1.351.110.4.3.1.4.1.1.5 | Counter32 | read-only | The number of Framing Pattern Errors encountered by
a DS1 interface. |
| C32 rcvLOSCountEx | 1.3.6.1.4.1.351.110.4.3.1.4.1.1.2 | Counter32 | read-only | The number of times the Loss of Signal was detected
with or without integrating to LOS alarm. |
| C32 rcvOOFCount | 1.3.6.1.4.1.351.110.4.3.1.4.1.1.3 | Counter32 | read-only | The number of times the Out of Frame was detected
with or without integrating to OOF alarm. |
| C32 rcvRAICount | 1.3.6.1.4.1.351.110.4.3.1.4.1.1.4 | Counter32 | read-only | The number of times Yellow Alarms was detected with
or without integrating to RAI alarm. |
| INT redSeverity | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.2 | INTEGER | read-write | This variable is used to setup the severity of RED
alarm. So when RED alarm is detected by the card, an
alarm with appropriate severity status will be sent. |
| C32 sEFS15MinBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.23 | Counter32 | read-only | This counter counts the number of
Severely Errored Framing Seconds in the last 15 minutes
encountered by the interface. |
| I32 sEFS15MinThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.23 | Integer32 | read-write | Severely Errored Framing Second - is a count of one-second
intervals containing one or more SEF events.
The value set in this object determines the value
which when exceeded in a 15 minute window causes
a statistical alarm to be declared. |
| C32 sEFS24HrBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.24 | Counter32 | read-only | This counter counts the number of
Severely Errored Framing Seconds in the last 24 hours
encountered by the interface. |
| I32 sEFS24HrThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.24 | Integer32 | read-write | Severely Errored Framing Second - is a count of one-second
intervals containing one or more SEF events.
The value set in this object determines the value
which when exceeded in a sliding 24 hour window causes
a statistical alarm to be declared. The threshold is
checked every 15 minutes for the preceding 24 hour interval |
| C32 sEFSCurrent | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.22 | Counter32 | read-only | This counter counts the number of
Severely Errored Framing Seconds
encountered by the interface. |
| INT statisticalAlarmSeverity | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.10 | INTEGER | read-write | This variable is used to setup the severity of Statistical
alarm. So when any statistical alarm is detected by the card,
an alarm with appropriate severity status will be sent. |
| C32 uAS15MinBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.29 | Counter32 | read-only | This counter counts the number of
Unavailable Seconds in the last 15 minutes
encountered by the interface. |
| I32 uAS15MinThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.27 | Integer32 | read-write | Unavailable Second - is a count of seconds during
which the DS1 Layer service is unavailable.
The value set in this object determines the value
which when exceeded in a 15 minute window causes
a statistical alarm to be declared. |
| C32 uAS24HrBucket | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.30 | Counter32 | read-only | This counter counts the number of
Unavailable Seconds in the last 24 hours
encountered by the interface. |
| I32 uAS24HrThreshold | 1.3.6.1.4.1.351.110.4.3.1.2.1.1.28 | Integer32 | read-write | Unavailable Second - is a count of seconds during
which the DS1 Layer service is unavailable.
The value set in this object determines the value
which when exceeded in a sliding 24 hour window causes
a statistical alarm to be declared. The threshold is
checked every 15 minutes for the preceding 24 hour interval |
| C32 uASCurrent | 1.3.6.1.4.1.351.110.4.3.1.3.1.1.28 | Counter32 | read-only | This counter counts the number of
Unavailable Seconds
encountered by the interface. |