Organization: Sinetica Corporation
Last Updated: 2006-06-27
Category: Hardware and Environment
Description: Monitors environmental and power parameters for Sinetica Hawk-I2 intelligent monitoring units in data centers.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is HAWK-I2-MIB?
HAWK-I2-MIB is a Sinetica Corporation (enterprise OID 3711) proprietary MIB for the Sinetica Hawk-i2 environmental-monitoring unit. Its objects cover IP-select/insert settings, temperature-scale flag, a THA (Temperature/Humidity/Analog) channel table (channel, reading-set, name, location, auto-detect flag, type, value, scaling, offset, hysteresis), and a threshold table (channel, reading-set, upper/lower control/warning limits) with a trap-enable table. As a status/performance MIB it lets an administrator watch environmental sensor readings against configured control/warning limits on a Sinetica Hawk-i2 unit. It is deployed on the Sinetica Corporation Hawk-i2 environmental-monitoring unit. Engineers can download the HAWK-I2-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in HAWK-I2-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Sinetica Corporation Hawk-i2 environmental-monitoring unit
Monitoring Examples
An administrator monitors ipTHAValue against ipTHAThreshUCL/ipTHAThreshLCL to catch an environmental sensor reading outside its control limits on a Sinetica Hawk-i2 unit.
What Can Be Monitored
- environmental sensor readings vs. control/warning thresholds
This MIB depends on
Related MIBs
Imported Objects
From INET-ADDRESS-MIB
| InetAddress | |
| InetAddressType |
From SNMPv2-SMI
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 | |
| enterprises |
From SNMPv2-TC
| MacAddress | |
| RowStatus | |
| TEXTUAL-CONVENTION | |
| TruthValue |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| sinetica | 1.3.6.1.4.1.3711 | |||
| hawki2MIB | 1.3.6.1.4.1.3711.24 | The MIB module for the Sinetica Hawk-i2. | ||
| traps | 1.3.6.1.4.1.3711.24.0 | |||
| NTF alarmCritical | 1.3.6.1.4.1.3711.24.0.1 | Critical alarm. | ||
| NTF alarmWarning | 1.3.6.1.4.1.3711.24.0.2 | Warning alarm. | ||
| NTF alarmInformation | 1.3.6.1.4.1.3711.24.0.3 | Information alarm. | ||
| NTF alarmCleared | 1.3.6.1.4.1.3711.24.0.4 | Alarm cleared. | ||
| v1 | 1.3.6.1.4.1.3711.24.1 | |||
| objects | 1.3.6.1.4.1.3711.24.1.1 | |||
| inputs | 1.3.6.1.4.1.3711.24.1.1.1 | |||
| ipCommon | 1.3.6.1.4.1.3711.24.1.1.1.1 | |||
| ipEnable | 1.3.6.1.4.1.3711.24.1.1.1.1.1 | |||
| INT ipSelect | 1.3.6.1.4.1.3711.24.1.1.1.1.1.1 | INTEGER | read-write | Selects the channel to be enabled or disabled by ipInsert. A value of 0 selects no channel. |
| INP ipInsert | 1.3.6.1.4.1.3711.24.1.1.1.1.1.2 | InputDataType | read-write | Inserts or removes the channel selected by ipSelect - causes an entry for that channel to be created or deleted in the relevant tables. - Read behaviour is undefined. |
| ipTHA | 1.3.6.1.4.1.3711.24.1.1.1.2 | |||
| INT ipTempScaleFlag | 1.3.6.1.4.1.3711.24.1.1.1.2.1 | INTEGER | read-write | Temperature scale (Celsius/Fahrenheit) for temperature monitoring. |
| ipTHATable | 1.3.6.1.4.1.3711.24.1.1.1.2.2 | not-accessible | A table giving data for all enabled inputs with analogue-type monitoring. | |
| ipTHAEntry | 1.3.6.1.4.1.3711.24.1.1.1.2.2.1 | not-accessible | A conceptual row containing information about one analogue-type input. | |
| INT ipTHAChan | 1.3.6.1.4.1.3711.24.1.1.1.2.2.1.1 | INTEGER | read-only | The input number. |
| ROW ipTHARS | 1.3.6.1.4.1.3711.24.1.1.1.2.2.1.2 | RowStatus | read-only | The analogue-type input table row status. |
| STR ipTHAName | 1.3.6.1.4.1.3711.24.1.1.1.2.2.1.3 | DisplayString | read-write | The name of this input |
| STR ipTHALocn | 1.3.6.1.4.1.3711.24.1.1.1.2.2.1.4 | DisplayString | read-only | A system-defined name for the physical location of this input, e.g. MCU. |
| T/F ipTHAAutoDetect | 1.3.6.1.4.1.3711.24.1.1.1.2.2.1.5 | TruthValue | read-write | Indicates that the type of data this input is monitoring is selected automatically. |
| INP ipTHAType | 1.3.6.1.4.1.3711.24.1.1.1.2.2.1.6 | InputDataType | read-write | Indicates the type of data this input is monitoring. |
| INT ipTHAValue | 1.3.6.1.4.1.3711.24.1.1.1.2.2.1.7 | INTEGER | read-only | The current reading in the relevant measurement units. |
| INT ipTHAScaling | 1.3.6.1.4.1.3711.24.1.1.1.2.2.1.8 | INTEGER | read-write | Scaling factor for ipTHAValue when ipTHAType=analogue. |
| INT ipTHAOffset | 1.3.6.1.4.1.3711.24.1.1.1.2.2.1.9 | INTEGER | read-write | Calibration offset in the same units as for ipTHAValue. |
| INT ipTHAHysteresis | 1.3.6.1.4.1.3711.24.1.1.1.2.2.1.10 | INTEGER | read-write | Hysteresis on threshold levels in the same units as for ipTHAValue. |
| ipTHATrapsCfg | 1.3.6.1.4.1.3711.24.1.1.1.2.3 | |||
| ipTHAThreshTable | 1.3.6.1.4.1.3711.24.1.1.1.2.3.1 | not-accessible | A table listing the trap threshold levels for all enabled inputs with analogue-type monitoring. | |
| ipTHAThreshEntry | 1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1 | not-accessible | A conceptual row containing threshold information for one analogue-type input. | |
| INT ipTHAThreshChan | 1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.1 | INTEGER | read-only | The input number. |
| ROW ipTHAThreshRS | 1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.2 | RowStatus | read-only | The analogue-type input table row status. |
| INT ipTHAUCL | 1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.3 | INTEGER | read-write | The Upper Critical Limit for this input in the same units as for ipTHAValue. |
| INT ipTHAUWL | 1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.4 | INTEGER | read-write | The Upper Warning Limit for this input in the same units as for ipTHAValue. |
| INT ipTHALWL | 1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.5 | INTEGER | read-write | The Lower Warning Limit for this input in the same units as for ipTHAValue. |
| INT ipTHALCL | 1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.6 | INTEGER | read-write | The Lower Critical Limit for this input in the same units as for ipTHAValue. |
| ipTHATrapEnTable | 1.3.6.1.4.1.3711.24.1.1.1.2.3.2 | not-accessible | The table that controls trap enabling for all enabled inputs with analogue-type monitoring. | |
| ipTHATrapEnEntry | 1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1 | not-accessible | A conceptual row containing trap enabling information for one analogue-type input. | |
| INT ipTHATrapEnChan | 1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.1 | INTEGER | read-only | The input number. |
| ROW ipTHATrapEnRS | 1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.2 | RowStatus | read-only | The analogue-type input table row status. |
| T/F ipTHAUCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.3 | TruthValue | read-write | Enables and disables input UCL alarm traps. |
| T/F ipTHAUWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.4 | TruthValue | read-write | Enables and disables input UWL alarm traps. |
| T/F ipTHALWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.5 | TruthValue | read-write | Enables and disables input LWL alarm traps. |
| T/F ipTHALCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.6 | TruthValue | read-write | Enables and disables input LCL alarm traps. |
| ipTHATrapPerTable | 1.3.6.1.4.1.3711.24.1.1.1.2.3.3 | not-accessible | The table that controls trap repetition for all enabled inputs with analogue-type monitoring. | |
| ipTHATrapPerEntry | 1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1 | not-accessible | A conceptual row containing trap repetition information for one analogue-type input. | |
| INT ipTHATrapPerChan | 1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.1 | INTEGER | read-only | The input number. |
| ROW ipTHATrapPerRS | 1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.2 | RowStatus | read-only | The table row status. |
| INT ipTHATrapUCLPer | 1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.3 | INTEGER | read-write | Set to 0 disables trap repetition, a value of 30 or higher sets the interval between traps in seconds |
| INT ipTHATrapUWLPer | 1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.4 | INTEGER | read-write | Set to 0 disables trap repetition, a value of 30 or higher sets the interval between traps in seconds |
| INT ipTHATrapLWLPer | 1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.5 | INTEGER | read-write | Set to 0 disables trap repetition, a value of 30 or higher sets the interval between traps in seconds |
| INT ipTHATrapLCLPer | 1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.6 | INTEGER | read-write | Set to 0 disables trap repetition, a value of 30 or higher sets the interval between traps in seconds |
| ipContact | 1.3.6.1.4.1.3711.24.1.1.1.3 | |||
| ipContTable | 1.3.6.1.4.1.3711.24.1.1.1.3.1 | not-accessible | A table listing the parameters and data for all enabled inputs with contact-type monitoring. | |
| ipContEntry | 1.3.6.1.4.1.3711.24.1.1.1.3.1.1 | not-accessible | A conceptual row containing information about one contact input. | |
| INT ipContChan | 1.3.6.1.4.1.3711.24.1.1.1.3.1.1.1 | INTEGER | read-only | The input number. |
| ROW ipContRS | 1.3.6.1.4.1.3711.24.1.1.1.3.1.1.2 | RowStatus | read-only | The contact input table row status. |
| STR ipContName | 1.3.6.1.4.1.3711.24.1.1.1.3.1.1.3 | DisplayString | read-write | The name of this input |
| STR ipContLocn | 1.3.6.1.4.1.3711.24.1.1.1.3.1.1.4 | DisplayString | read-only | A system-defined name for the physical location of this input, e.g. MCU. |
| T/F ipContAutoDetect | 1.3.6.1.4.1.3711.24.1.1.1.3.1.1.5 | TruthValue | read-write | Indicates that the type of data this input is monitoring is selected automatically. |
| CON ipContNormState | 1.3.6.1.4.1.3711.24.1.1.1.3.1.1.6 | ContactState | read-write | The normal state for this contact. |
| INP ipContCurrState | 1.3.6.1.4.1.3711.24.1.1.1.3.1.1.7 | InputContactState | read-only | The current state of this contact. |
| INT ipContTrigMode | 1.3.6.1.4.1.3711.24.1.1.1.3.1.1.8 | INTEGER | read-write | The contact trigger mode, level, +ve edge, -ve edge. |
| U32 ipContReset | 1.3.6.1.4.1.3711.24.1.1.1.3.1.1.9 | Unsigned32 | read-write | Resets the contact after triggering in edge mode. |
| INT ipContTrapEn | 1.3.6.1.4.1.3711.24.1.1.1.3.1.1.10 | INTEGER | read-write | Configure contact input traps. |
| INT ipContTrapPeriod | 1.3.6.1.4.1.3711.24.1.1.1.3.1.1.11 | INTEGER | read-write | Set to 0 disables trap repetition, a value of 30 or higher sets the interval between traps in seconds |
| outputs | 1.3.6.1.4.1.3711.24.1.1.2 | |||
| opEnable | 1.3.6.1.4.1.3711.24.1.1.2.1 | |||
| INT opSelect | 1.3.6.1.4.1.3711.24.1.1.2.1.1 | INTEGER | read-write | Selects the channel to be enabled or disabled by opEnable. A value of 0 selects no channel. |
| ENA opInsert | 1.3.6.1.4.1.3711.24.1.1.2.1.2 | EnableState | read-write | Enables or disables the channel selected by opSelect - causes an entry for that channel to be created or deleted in the relevant tables. - Read behaviour is undefined. |
| opTable | 1.3.6.1.4.1.3711.24.1.1.2.2 | not-accessible | A table listing the parameters and data for all outputs that are enabled and available (i.e. its extension unit is connected). | |
| opEntry | 1.3.6.1.4.1.3711.24.1.1.2.2.1 | not-accessible | A conceptual row containing information about one output. | |
| INT opChan | 1.3.6.1.4.1.3711.24.1.1.2.2.1.1 | INTEGER | read-only | The output number. |
| ROW opRS | 1.3.6.1.4.1.3711.24.1.1.2.2.1.2 | RowStatus | read-only | The contact input table row status. |
| STR opName | 1.3.6.1.4.1.3711.24.1.1.2.2.1.3 | DisplayString | read-write | A user-defined name for this output. |
| STR opLocn | 1.3.6.1.4.1.3711.24.1.1.2.2.1.4 | DisplayString | read-only | A system-defined name for the physical location of this output, e.g. MCU. |
| REL opNormState | 1.3.6.1.4.1.3711.24.1.1.2.2.1.5 | RelayState | read-write | Sets or reads the required normal state of this output. |
| REL opCurrState | 1.3.6.1.4.1.3711.24.1.1.2.2.1.6 | RelayState | read-only | Reads the current state of this output. |
| U32 opOnDelTime | 1.3.6.1.4.1.3711.24.1.1.2.2.1.7 | Unsigned32 | read-write | Sets the 'on' delay time for this output. |
| U32 opOffDelTime | 1.3.6.1.4.1.3711.24.1.1.2.2.1.8 | Unsigned32 | read-write | Sets the 'off' delay time for this output. |
| STR opBooleanEqn | 1.3.6.1.4.1.3711.24.1.1.2.2.1.9 | DisplayString | read-write | Boolean equation string |
| INT opTrapEn | 1.3.6.1.4.1.3711.24.1.1.2.2.1.10 | INTEGER | read-write | Configure output traps. |
| INT opTrapPeriod | 1.3.6.1.4.1.3711.24.1.1.2.2.1.11 | INTEGER | read-write | Set to 0 disables trap repetition, a value of 30 or higher sets the interval between traps in seconds |
| OUT opControlState | 1.3.6.1.4.1.3711.24.1.1.2.2.1.12 | OutputControlState | read-write | Reads the current control state of an output. |
| keypads | 1.3.6.1.4.1.3711.24.1.1.4 | |||
| kpEnable | 1.3.6.1.4.1.3711.24.1.1.4.1 | |||
| INT kpSelect | 1.3.6.1.4.1.3711.24.1.1.4.1.1 | INTEGER | read-write | Selects the keypad to be enabled or disabled by kpEnable. A value of 0 selects no keypad. |
| ENA kpInsert | 1.3.6.1.4.1.3711.24.1.1.4.1.2 | EnableState | read-write | Enables or disables the keypad selected by kpSelect - causes an entry for that keypad to be created or deleted in the relevant tables. - Read behaviour is undefined. |
| kpCtlTable | 1.3.6.1.4.1.3711.24.1.1.4.2 | not-accessible | A table listing the parameters and data for the keypads. | |
| kpCtlEntry | 1.3.6.1.4.1.3711.24.1.1.4.2.1 | not-accessible | A conceptual row containing information about one keypad. | |
| INT kpNumber | 1.3.6.1.4.1.3711.24.1.1.4.2.1.1 | INTEGER | read-only | The keypad number. |
| ROW kpRS | 1.3.6.1.4.1.3711.24.1.1.4.2.1.2 | RowStatus | read-only | The keypad table row status. |
| STR kpManufacturer | 1.3.6.1.4.1.3711.24.1.1.4.2.1.3 | DisplayString | read-write | The name of the manufacturer of the keypad. |
| STR kpName | 1.3.6.1.4.1.3711.24.1.1.4.2.1.4 | DisplayString | read-write | A name identifying the keypad. |
| U32 kpDoorLatchTimeOut | 1.3.6.1.4.1.3711.24.1.1.4.2.1.5 | Unsigned32 | read-write | Time-out value in seconds for which the door latch is held open. |
| INT kpRtnToStndbyTimeOut | 1.3.6.1.4.1.3711.24.1.1.4.2.1.6 | INTEGER | read-write | Time-out value in seconds for Return to Standby Mode |
| T/F kpEntryCodeValid | 1.3.6.1.4.1.3711.24.1.1.4.2.1.7 | TruthValue | read-only | Set if previous keypad entry was valid. |
| INT kpDoorOpenTimeOut | 1.3.6.1.4.1.3711.24.1.1.4.2.1.8 | INTEGER | read-write | Time-out value in seconds for Door Open. |
| T/F kpRemoteDoorOpen | 1.3.6.1.4.1.3711.24.1.1.4.2.1.9 | TruthValue | read-write | Set to open the door. |
| INT kpInUseTrapEn | 1.3.6.1.4.1.3711.24.1.1.4.2.1.10 | INTEGER | read-write | 'keypad in use' trap enable |
| acus | 1.3.6.1.4.1.3711.24.1.1.5 | |||
| acuEnable | 1.3.6.1.4.1.3711.24.1.1.5.1 | |||
| INT acuSelect | 1.3.6.1.4.1.3711.24.1.1.5.1.1 | INTEGER | read-write | Selects the ACU to be enabled or disabled by acuEnable. A value of 0 selects no ACU. |
| ENA acuInsert | 1.3.6.1.4.1.3711.24.1.1.5.1.2 | EnableState | read-write | Enables or disables the ACU selected by acuSelect - causes an entry for that ACU to be created or deleted in the relevant tables. - Read behaviour is undefined. |
| acuCtlTable | 1.3.6.1.4.1.3711.24.1.1.5.2 | not-accessible | A table listing the parameters and data for the ACUs. | |
| acuCtlEntry | 1.3.6.1.4.1.3711.24.1.1.5.2.1 | not-accessible | A conceptual row containing information about one ACU. | |
| INT acuNumber | 1.3.6.1.4.1.3711.24.1.1.5.2.1.1 | INTEGER | read-only | The ACU number. |
| ROW acuCtlRS | 1.3.6.1.4.1.3711.24.1.1.5.2.1.2 | RowStatus | read-only | The ACU table row status. |
| STR acuManufacturer | 1.3.6.1.4.1.3711.24.1.1.5.2.1.3 | DisplayString | read-write | The name of the manufacturer of the ACU. |
| STR acuName | 1.3.6.1.4.1.3711.24.1.1.5.2.1.4 | DisplayString | read-write | A name identifying the ACU. |
| U32 acuDoorLatchTimeOut | 1.3.6.1.4.1.3711.24.1.1.5.2.1.5 | Unsigned32 | read-write | Time-out value in seconds for which the door latch is held open. |
| INT acuRtnToStndbyTimeOut | 1.3.6.1.4.1.3711.24.1.1.5.2.1.6 | INTEGER | read-write | Time-out value in seconds for Return to Standby Mode |
| T/F acuEntryCodeValid | 1.3.6.1.4.1.3711.24.1.1.5.2.1.7 | TruthValue | read-only | Set if previous ACU entry was valid. |
| INT acuDoorOpenTimeOut | 1.3.6.1.4.1.3711.24.1.1.5.2.1.8 | INTEGER | read-write | Time-out value in seconds for Door Open. |
| T/F acuRemoteDoorOpen | 1.3.6.1.4.1.3711.24.1.1.5.2.1.9 | TruthValue | read-write | Set to open the door. |
| INT acuInUseTrapEn | 1.3.6.1.4.1.3711.24.1.1.5.2.1.10 | INTEGER | read-write | 'ACU in use' trap enable |
| access | 1.3.6.1.4.1.3711.24.1.1.6 | |||
| accUserCtl | 1.3.6.1.4.1.3711.24.1.1.6.1 | |||
| U32 accUserInstance | 1.3.6.1.4.1.3711.24.1.1.6.1.1 | Unsigned32 | read-write | A value of 0 causes an access user to be created in the relevant tables. A non-zero value causes the nominated access user table entries to be deleted. |
| accUserTable | 1.3.6.1.4.1.3711.24.1.1.6.1.2 | not-accessible | A table controlling the access users. | |
| accUserEntry | 1.3.6.1.4.1.3711.24.1.1.6.1.2.1 | not-accessible | A conceptual row containing information about one ACU user. | |
| INT accUserNumber | 1.3.6.1.4.1.3711.24.1.1.6.1.2.1.1 | INTEGER | read-only | The the access user-table entry number. |
| ROW accUserRS | 1.3.6.1.4.1.3711.24.1.1.6.1.2.1.2 | RowStatus | read-only | The access user table row status. |
| STR accUserName | 1.3.6.1.4.1.3711.24.1.1.6.1.2.1.3 | DisplayString | read-write | A name identifying the access user. |
| OCT accUserCode | 1.3.6.1.4.1.3711.24.1.1.6.1.2.1.4 | OCTET STRING | read-write | The user's access code. |
| STR accUserPrivileges | 1.3.6.1.4.1.3711.24.1.1.6.1.2.1.5 | DisplayString | read-write | The ACUs and keypads that the user is allowed to gain access through - comma-separated numerical strings. |
| STR accUserExpires | 1.3.6.1.4.1.3711.24.1.1.6.1.2.1.6 | DisplayString | read-write | A text string which specifies when the access code in the row expires. The format is defined by the application. |
| OCT accUserSetup | 1.3.6.1.4.1.3711.24.1.1.6.1.3 | OCTET STRING | read-write | A free form octet string for programming accUserTable. The format is defined by the application. |
| pdus | 1.3.6.1.4.1.3711.24.1.1.7 | |||
| pduCommon | 1.3.6.1.4.1.3711.24.1.1.7.1 | |||
| pdusEnable | 1.3.6.1.4.1.3711.24.1.1.7.1.1 | |||
| INT pduSelect | 1.3.6.1.4.1.3711.24.1.1.7.1.1.1 | INTEGER | read-write | Selects the PDU to be enabled or disabled by pduEnable. A value of 0 selects no PDU. |
| ENA pduInsert | 1.3.6.1.4.1.3711.24.1.1.7.1.1.2 | EnableState | read-write | Enables or disables the PDU selected by pduSelect - causes an entry for that PDU to be created or deleted in the relevant tables. - Read behaviour is undefined. |
| pduTable | 1.3.6.1.4.1.3711.24.1.1.7.1.2 | not-accessible | A table containing information about each enabled PDU. | |
| pduEntry | 1.3.6.1.4.1.3711.24.1.1.7.1.2.1 | not-accessible | A conceptual row containing information about one PDU. | |
| INT pduNumber | 1.3.6.1.4.1.3711.24.1.1.7.1.2.1.1 | INTEGER | read-only | The PDU number. |
| ROW pduRS | 1.3.6.1.4.1.3711.24.1.1.7.1.2.1.2 | RowStatus | read-only | The PDU table row status. |
| STR pduName | 1.3.6.1.4.1.3711.24.1.1.7.1.2.1.3 | DisplayString | read-write | A string identifying the PDU. |
| T/F pduOutEn | 1.3.6.1.4.1.3711.24.1.1.7.1.2.1.4 | TruthValue | read-write | Enables/disables PDU power outlet control - causes an entry for outlets to be created in each relevant PDU table. |
| T/F pduMonEn | 1.3.6.1.4.1.3711.24.1.1.7.1.2.1.5 | TruthValue | read-write | Enables/disables PDU power monitoring - causes an entry for monitoring to be created in each relevant PDU table. |
| INT pduCommsFail | 1.3.6.1.4.1.3711.24.1.1.7.1.2.1.6 | INTEGER | read-only | Indicates comms. status for the PDU. |
| pduOutlets | 1.3.6.1.4.1.3711.24.1.1.7.2 | |||
| pduOutAll | 1.3.6.1.4.1.3711.24.1.1.7.2.1 | |||
| INT pduOutCycleAll | 1.3.6.1.4.1.3711.24.1.1.7.2.1.1 | INTEGER | read-write | Sets the required state of all power outlets on all connected PDUs. |
| STR pduOutCycleAllPwd | 1.3.6.1.4.1.3711.24.1.1.7.2.1.2 | DisplayString | read-write | Controls access to setting the required state of all power outlets on all connected PDUs. |
| U32 pduOutCycleAllAbort | 1.3.6.1.4.1.3711.24.1.1.7.2.1.3 | Unsigned32 | read-write | Abort command for pduOutCycleAll. |
| U32 pduOutGlobalCycleDelay | 1.3.6.1.4.1.3711.24.1.1.7.2.1.4 | Unsigned32 | read-write | Sets the delay period for pduOutCycleAll and pduOutCycle commands before they start to execute. |
| U32 pduOutGlobalRebootTime | 1.3.6.1.4.1.3711.24.1.1.7.2.1.5 | Unsigned32 | read-write | Sets the off to on delay period for a pdu outlet reboot. |
| U32 pduOutGlobalCycleAbortTime | 1.3.6.1.4.1.3711.24.1.1.7.2.1.6 | Unsigned32 | read-write | Time delay to abort power outlet setting task. |
| pduOutCmnTable | 1.3.6.1.4.1.3711.24.1.1.7.2.2 | not-accessible | A table containing information about the power outlets of all PDUs enabled for outlet control. | |
| pduOutCmnEntry | 1.3.6.1.4.1.3711.24.1.1.7.2.2.1 | not-accessible | A conceptual row containing information about the power outlets of one PDU. | |
| INT pduOutCmnPduNumber | 1.3.6.1.4.1.3711.24.1.1.7.2.2.1.1 | INTEGER | read-only | The PDU number. |
| ROW pduOutCmnRS | 1.3.6.1.4.1.3711.24.1.1.7.2.2.1.2 | RowStatus | read-only | The PDU table row status. |
| INT pduNumOfOutlets | 1.3.6.1.4.1.3711.24.1.1.7.2.2.1.3 | INTEGER | read-write | The number of switchable outlets on the PDU - determines the number of entries to be created in the outlet table for the relevant PDU. |
| INT pduOutCycle | 1.3.6.1.4.1.3711.24.1.1.7.2.2.1.4 | INTEGER | read-write | Sets the required state of all power outlets on the PDU. |
| STR pduOutCyclePwd | 1.3.6.1.4.1.3711.24.1.1.7.2.2.1.5 | DisplayString | read-write | Password controling access to setting the required state of all power outlets on the PDU. |
| U32 pduOutCycleAbortTask | 1.3.6.1.4.1.3711.24.1.1.7.2.2.1.6 | Unsigned32 | read-write | Abort power outlet setting task. |
| U32 pduOutCycleAbortTime | 1.3.6.1.4.1.3711.24.1.1.7.2.2.1.7 | Unsigned32 | read-write | Time delay to abort power outlet setting task. |
| pduOutTable | 1.3.6.1.4.1.3711.24.1.1.7.2.3 | not-accessible | A table listing the states and descriptions for each outlet on the PDU. | |
| pduOutEntry | 1.3.6.1.4.1.3711.24.1.1.7.2.3.1 | not-accessible | A row containing information about one PDU outlet. | |
| INT pduOutPduNumber | 1.3.6.1.4.1.3711.24.1.1.7.2.3.1.1 | INTEGER | read-only | The PDU number on which the outlet resides. |
| INT pduOutNumber | 1.3.6.1.4.1.3711.24.1.1.7.2.3.1.2 | INTEGER | read-only | The outlet number. |
| ROW pduOutRS | 1.3.6.1.4.1.3711.24.1.1.7.2.3.1.3 | RowStatus | read-only | The PDU table row status. |
| STR pduOutName | 1.3.6.1.4.1.3711.24.1.1.7.2.3.1.4 | DisplayString | read-write | A name identifying the outlet. |
| INT pduOutOn | 1.3.6.1.4.1.3711.24.1.1.7.2.3.1.5 | INTEGER | read-write | The current state for this outlet. |
| STR pduOutPwd | 1.3.6.1.4.1.3711.24.1.1.7.2.3.1.6 | DisplayString | read-write | The password for this outlet. |
| U32 pduOutCycleDelay | 1.3.6.1.4.1.3711.24.1.1.7.2.3.1.7 | Unsigned32 | read-only | The on/off delay for this outlet in seconds. |
| U32 pduOutRebootPeriod | 1.3.6.1.4.1.3711.24.1.1.7.2.3.1.8 | Unsigned32 | read-only | The pduOutOn reboot off period for this outlet in seconds. |
| pduMonitor | 1.3.6.1.4.1.3711.24.1.1.7.3 | |||
| pduMonTable | 1.3.6.1.4.1.3711.24.1.1.7.3.1 | not-accessible | A table containing monitor information for all PDUs enabled for monitoring. | |
| pduMonEntry | 1.3.6.1.4.1.3711.24.1.1.7.3.1.1 | not-accessible | A conceptual row containing monitor information for one PDU. | |
| INT pduMonPduNumber | 1.3.6.1.4.1.3711.24.1.1.7.3.1.1.1 | INTEGER | read-only | The PDU number. |
| ROW pduMonRS | 1.3.6.1.4.1.3711.24.1.1.7.3.1.1.2 | RowStatus | read-only | The PDU table row status. |
| INT pduRMSVoltsValue | 1.3.6.1.4.1.3711.24.1.1.7.3.1.1.3 | INTEGER | read-only | RMS Volts value in volts |
| INT pduRMSAmpsValue | 1.3.6.1.4.1.3711.24.1.1.7.3.1.1.4 | INTEGER | read-only | RMS current value in 0.1 Amps |
| INT pduTotalEnergyValue | 1.3.6.1.4.1.3711.24.1.1.7.3.1.1.5 | INTEGER | read-only | Total energy value in 0.1 kWh |
| INT pduMeanKVAValue | 1.3.6.1.4.1.3711.24.1.1.7.3.1.1.6 | INTEGER | read-only | Kilo Volt-Amperes value in 0.1 kVA |
| INT pduMeanKWattsValue | 1.3.6.1.4.1.3711.24.1.1.7.3.1.1.7 | INTEGER | read-only | Kilo Watts value in 0.1 kW |
| INT pduPwrFactorValue | 1.3.6.1.4.1.3711.24.1.1.7.3.1.1.8 | INTEGER | read-only | Power factor value in 0.01 |
| pduTrapThreshTable | 1.3.6.1.4.1.3711.24.1.1.7.3.2 | not-accessible | A table containing information about the trap threshold values for all PDUs enabled for monitoring. | |
| pduTrapThreshEntry | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1 | not-accessible | A conceptual row containing information about the trap threshold values for one PDU. | |
| INT pduTrapThreshPduNumber | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.1 | INTEGER | read-only | The PDU number. |
| ROW pduTrapThreshRS | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.2 | RowStatus | read-only | The PDU table row status. |
| INT pduRMSVoltsUCL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.3 | INTEGER | read-write | rms UCL value in volts |
| INT pduRMSVoltsUWL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.4 | INTEGER | read-write | rms UWL value in volts |
| INT pduRMSVoltsLWL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.5 | INTEGER | read-write | rms LWL value in volts |
| INT pduRMSVoltsLCL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.6 | INTEGER | read-write | rms LCL value in volts |
| INT pduRMSAmpsUCL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.7 | INTEGER | read-write | rms UCL value in 0.1 amps |
| INT pduRMSAmpsUWL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.8 | INTEGER | read-write | rms UWL value in 0.1 amps |
| INT pduRMSAmpsLWL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.9 | INTEGER | read-write | rms LWL value in 0.1 amps |
| INT pduRMSAmpsLCL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.10 | INTEGER | read-write | rms LCL value in 0.1 amps |
| INT pduEnergyUCL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.11 | INTEGER | read-write | Total energy UCL value in 0.1 kWh |
| INT pduEnergyUWL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.12 | INTEGER | read-write | Total energy UWL value in 0.1 kWh |
| INT pduMeanKVAUCL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.13 | INTEGER | read-write | Mean kVA UCL value in 0.1 kVA |
| INT pduMeanKVAUWL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.14 | INTEGER | read-write | Mean kVA UWL value in 0.1 kVA |
| INT pduMeanKVALWL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.15 | INTEGER | read-write | Mean kVA LWL value in 0.1 kVA |
| INT pduMeanKVALCL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.16 | INTEGER | read-write | Mean kVA LCL value in 0.1 kVA |
| INT pduMeanKWattsUCL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.17 | INTEGER | read-write | Mean power UCL value in 0.1 kW |
| INT pduMeanKWattsUWL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.18 | INTEGER | read-write | Mean power UWL value in 0.1 kW |
| INT pduMeanKWattsLWL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.19 | INTEGER | read-write | Mean power LWL value in 0.1 kW |
| INT pduMeanKWattsLCL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.20 | INTEGER | read-write | Mean power LCL value in 0.1 kW |
| INT pduPwrFactorUCL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.21 | INTEGER | read-write | Power factor UCL value in 0.01 |
| INT pduPwrFactorUWL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.22 | INTEGER | read-write | Power factor UWL value in 0.01 |
| INT pduPwrFactorLWL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.23 | INTEGER | read-write | Power factor LWL value in 0.01 |
| INT pduPwrFactorLCL | 1.3.6.1.4.1.3711.24.1.1.7.3.2.1.24 | INTEGER | read-write | Power factor LCL value in 0.01 |
| pduTrapEnTable | 1.3.6.1.4.1.3711.24.1.1.7.3.3 | not-accessible | The table which controls threshold value trap enabling for all PDUs enabled for monitoring. | |
| pduTrapEnEntry | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1 | not-accessible | A conceptual row containing information about one PDU. | |
| INT pduTrapEnPduNumber | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.1 | INTEGER | read-only | The PDU number. |
| ROW pduTrapEnRS | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.2 | RowStatus | read-only | The PDU table row status. |
| T/F pduRMSVoltsUCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.3 | TruthValue | read-write | Enables Volts UCL trap. |
| T/F pduRMSVoltsUWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.4 | TruthValue | read-write | Enables UWL Volts trap. |
| T/F pduRMSVoltsLWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.5 | TruthValue | read-write | Enables LWL Volts trap. |
| T/F pduRMSVoltsLCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.6 | TruthValue | read-write | Enables LCL Volts trap. |
| T/F pduRMSAmpsUCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.7 | TruthValue | read-write | Enables UCL current trap. |
| T/F pduRMSAmpsUWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.8 | TruthValue | read-write | Enables UWL current trap. |
| T/F pduRMSAmpsLWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.9 | TruthValue | read-write | Enables LWL current trap. |
| T/F pduRMSAmpsLCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.10 | TruthValue | read-write | Enables LCL current trap. |
| T/F pduEnergyUCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.11 | TruthValue | read-write | Enables UCL total energy trap. |
| T/F pduEnergyUWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.12 | TruthValue | read-write | Enables UWL total energy trap. |
| T/F pduMeanKVAUCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.13 | TruthValue | read-write | Enables mean kVA UCL trap. |
| T/F pduMeanKVAUWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.14 | TruthValue | read-write | Enables mean kVA UWL trap. |
| T/F pduMeanKVALWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.15 | TruthValue | read-write | Enables mean kVA LWL trap. |
| T/F pduMeanKVALCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.16 | TruthValue | read-write | Enables mean kVA LCL trap. |
| T/F pduMeanKWattsUCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.17 | TruthValue | read-write | Enables mean power UCL trap. |
| T/F pduMeanKWattsUWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.18 | TruthValue | read-write | Enables mean power UWL trap. |
| T/F pduMeanKWattsLWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.19 | TruthValue | read-write | Enables mean power LWL trap. |
| T/F pduMeanKWattsLCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.20 | TruthValue | read-write | Enables mean power LCL trap. |
| T/F pduPwrFactorUCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.21 | TruthValue | read-write | Enables power factor UCL trap. |
| T/F pduPwrFactorUWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.22 | TruthValue | read-write | Enables power factor UWL trap. |
| T/F pduPwrFactorLWLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.23 | TruthValue | read-write | Enables power factor LWL trap. |
| T/F pduPwrFactorLCLTrapEn | 1.3.6.1.4.1.3711.24.1.1.7.3.3.1.24 | TruthValue | read-write | Enables power factor LCL trap. |
| pduTrapPerTable | 1.3.6.1.4.1.3711.24.1.1.7.3.4 | not-accessible | The table which controls threshold value trap repetition for all PDUs enabled for monitoring. | |
| pduTrapPerEntry | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1 | not-accessible | A conceptual row containing information about one PDU. | |
| INT pduTrapPduNumber | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.1 | INTEGER | read-only | The PDU number. |
| ROW pduTrapPerRS | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.2 | RowStatus | read-only | The PDU table row status. |
| INT pduRMSVoltsUCLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.3 | INTEGER | read-write | Sets UCL Volts trap repeat rate in seconds |
| INT pduRMSVoltsUWLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.4 | INTEGER | read-write | Sets UWL Volts trap repeat rate in seconds |
| INT pduRMSVoltsLWLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.5 | INTEGER | read-write | Sets LWL Volts trap repeat rate in seconds |
| INT pduRMSVoltsLCLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.6 | INTEGER | read-write | Sets LCL Volts trap repeat rate in seconds |
| INT pduRMSAmpsUCLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.7 | INTEGER | read-write | Sets UCL current trap repeat rate in seconds |
| INT pduRMSAmpsUWLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.8 | INTEGER | read-write | Sets UWL current trap repeat rate in seconds |
| INT pduRMSAmpsLWLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.9 | INTEGER | read-write | Sets LWL current trap repeat rate in seconds |
| INT pduRMSAmpsLCLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.10 | INTEGER | read-write | Sets LCL current trap repeat rate in seconds |
| INT pduEnergyUCLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.11 | INTEGER | read-write | Sets UCL total energy trap repeat rate in seconds |
| INT pduEnergyUWLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.12 | INTEGER | read-write | Sets UWL total energy trap repeat rate in seconds |
| INT pduMeanKVAUCLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.13 | INTEGER | read-write | Sets mean kVA UCL trap repeat rate in seconds |
| INT pduMeanKVAUWLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.14 | INTEGER | read-write | Sets mean kVA UWL trap repeat rate in seconds |
| INT pduMeanKVALWLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.15 | INTEGER | read-write | Sets mean kVA LWL trap repeat rate in seconds |
| INT pduMeanKVALCLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.16 | INTEGER | read-write | Sets mean kVA LCL trap repeat rate in seconds |
| INT pduMeanKWattsUCLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.17 | INTEGER | read-write | Sets mean power UCL trap repeat rate in seconds |
| INT pduMeanKWattsUWLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.18 | INTEGER | read-write | Sets mean power UWL trap repeat rate in seconds |
| INT pduMeanKWattsLWLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.19 | INTEGER | read-write | Sets mean power LWL trap repeat rate in seconds |
| INT pduMeanKWattsLCLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.20 | INTEGER | read-write | Sets mean power LCL trap repeat rate in seconds |
| INT pduPwrFactorUCLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.21 | INTEGER | read-write | Sets power factor UCL trap repeat rate in seconds |
| INT pduPwrFactorUWLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.22 | INTEGER | read-write | Sets power factor UWL trap repeat rate in seconds |
| INT pduPwrFactorLWLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.23 | INTEGER | read-write | Sets power factor LWL trap repeat rate in seconds |
| INT pduPwrFactorLCLTrapPer | 1.3.6.1.4.1.3711.24.1.1.7.3.4.1.24 | INTEGER | read-write | Sets power factor LCL trap repeat rate in seconds |
| inventory | 1.3.6.1.4.1.3711.24.1.1.99 | |||
| STR invProdSignature | 1.3.6.1.4.1.3711.24.1.1.99.1 | DisplayString | read-only | Product data signature. |
| STR invProdFormatVer | 1.3.6.1.4.1.3711.24.1.1.99.2 | DisplayString | read-only | Product data format version. |
| STR invManufCode | 1.3.6.1.4.1.3711.24.1.1.99.3 | DisplayString | read-only | Manufacturer code. |
| STR invOrderNum | 1.3.6.1.4.1.3711.24.1.1.99.4 | DisplayString | read-only | Order number. |
| STR invBatchNum | 1.3.6.1.4.1.3711.24.1.1.99.5 | DisplayString | read-only | Batch number. |
| STR invProdTestTime | 1.3.6.1.4.1.3711.24.1.1.99.6 | DisplayString | read-only | Data and time of production test. |
| STR invUnitName | 1.3.6.1.4.1.3711.24.1.1.99.7 | DisplayString | read-only | Unit name. |
| STR invUnitPartNum | 1.3.6.1.4.1.3711.24.1.1.99.8 | DisplayString | read-only | Unit part number. |
| STR invHwRevision | 1.3.6.1.4.1.3711.24.1.1.99.9 | DisplayString | read-only | Hardware revision number. |
| STR invFwRevision | 1.3.6.1.4.1.3711.24.1.1.99.10 | DisplayString | read-only | Firmware revision number. |
| STR invSerialNum | 1.3.6.1.4.1.3711.24.1.1.99.11 | DisplayString | read-only | Serial number. |
| IPt invDefaultIPAddrType | 1.3.6.1.4.1.3711.24.1.1.99.12 | InetAddressType | read-only | The type of the IP addresses. |
| IP invDefaultIPAddr | 1.3.6.1.4.1.3711.24.1.1.99.13 | InetAddress | read-only | Default unit IP address. |
| IP invDefaultSubNetMask | 1.3.6.1.4.1.3711.24.1.1.99.14 | InetAddress | read-only | Default unit sub-network mask. |
| IP invDefaultGWAddr | 1.3.6.1.4.1.3711.24.1.1.99.15 | InetAddress | read-only | Default unit default gateway address. |
| MAC invMacAddr | 1.3.6.1.4.1.3711.24.1.1.99.16 | MacAddress | read-only | Unit medium access control (MAC) address. |
| T/F invOk | 1.3.6.1.4.1.3711.24.1.1.99.20 | TruthValue | read-only | Confirms that the inventory record isn't corrupted. |
| INT invInputCount | 1.3.6.1.4.1.3711.24.1.1.99.50 | INTEGER | read-only | The maximum number of inputs that can be connected to the unit |
| INT invOutputCount | 1.3.6.1.4.1.3711.24.1.1.99.51 | INTEGER | read-only | The maximum number of outputs that can be connected to the unit |
| INT invKeypadCount | 1.3.6.1.4.1.3711.24.1.1.99.52 | INTEGER | read-only | The maximum number of keypads that can be connected to the unit |
| INT invAcuCount | 1.3.6.1.4.1.3711.24.1.1.99.53 | INTEGER | read-only | The maximum number of ACU's that can be connected to the unit |
| INT invAccessUserCount | 1.3.6.1.4.1.3711.24.1.1.99.54 | INTEGER | read-only | The maximum number of user entries on the unit |
| INT invPduCount | 1.3.6.1.4.1.3711.24.1.1.99.55 | INTEGER | read-only | The maximum number of PDU's that can be connected to the unit |
| trapInfo | 1.3.6.1.4.1.3711.24.1.1.100 | |||
| U32 trapCode | 1.3.6.1.4.1.3711.24.1.1.100.1 | Unsigned32 | read-only | A decimal number to be carried on notifications of types 1 to 4 identifying the event which caused it. The format of this number is BBEEffCCT where BB is the number of the relevant MIB branch. EE indicates what type of event caused the notification. This value is dependent upon branch number and implementation. CC is the channel number which was the source of the notification. T discriminates the type of data, e.g. temperature. This value is dependent upon branch number and implementation. ff future use. Fields are packed with leading zeros and are set to zero if not relevant to a particular notification. |
| STR trapDescription | 1.3.6.1.4.1.3711.24.1.1.100.2 | DisplayString | read-only | A string to be carried on notifications of types 1 to 4 identifying the event which caused it. The format of this string is as follows. Field 1 - type of notification, e.g. warning, critical, etc. Field 2 - data source, e.g. inputs. Generally this relates to a particular MIB branch. Field 3 - channel number, e.g. input 1. Field 4 - event, i.e. what caused the trap. Field 5 - value at which the event occured, e.g. 900, indicating 90% humidity. Field 6 - type of data, e.g. relative humidity Fields are omitted if not relevant to a particular notification. |
RFC description
Sinetica Hawk-i2 monitoring unit SNMP MIB. Provides management objects for the Hawk-i2 monitoring platform available in various device library systems.
Start monitoring Sinetica Corporation Hawk-i2 environmental-monitoring unit with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.