| OID symbolic | OID numeric | Type | Access | Description |
| argus | 1.3.6.1.4.1.7309 | | | This MIB defines the information block(s) available in CXC RMU
as defined by the following list:
- upsDevice: the CXC-series of controllers |
| upsPower | 1.3.6.1.4.1.7309.6 | | | |
| upsDevice | 1.3.6.1.4.1.7309.6.1 | | | |
| upsIdent | 1.3.6.1.4.1.7309.6.1.1 | | | |
| STR upsIdentManufacturer | 1.3.6.1.4.1.7309.6.1.1.1 | DisplayString | read-only | The name of the UPS manufacturer. |
| STR upsIdentProductCode | 1.3.6.1.4.1.7309.6.1.1.2 | DisplayString | read-only | The UPS Model designation. |
| STR upsIdentModel | 1.3.6.1.4.1.7309.6.1.1.3 | DisplayString | read-only | The UPS Product code designation. |
| STR upsIdentUPSSoftwareVersion | 1.3.6.1.4.1.7309.6.1.1.4 | DisplayString | read-only | The UPS firmware/software version(s). This variable
may or may not have the same value as
upsIdentAgentSoftwareVersion in some implementations. |
| STR upsIdentAgentSoftwareVersion | 1.3.6.1.4.1.7309.6.1.1.5 | DisplayString | read-only | The UPS agent software version. This variable may or
may not have the same value as
upsIdentUPSSoftwareVersion in some implementations. |
| STR upsIdentName | 1.3.6.1.4.1.7309.6.1.1.6 | DisplayString | read-only | A string identifying the UPS. This object should be
set by the administrator. |
| STR upsIdentAttachedDevices | 1.3.6.1.4.1.7309.6.1.1.7 | DisplayString | read-only | A string identifying the devices attached to the
output(s) of the UPS. This object should be set by
the administrator. |
| STR upsIdentSiteName | 1.3.6.1.4.1.7309.6.1.1.8 | DisplayString | read-write | Site Name |
| STR upsIdentSiteCity | 1.3.6.1.4.1.7309.6.1.1.9 | DisplayString | read-write | Site City |
| STR upsIdentSiteRegion | 1.3.6.1.4.1.7309.6.1.1.10 | DisplayString | read-write | Site Region |
| STR upsIdentSiteCountry | 1.3.6.1.4.1.7309.6.1.1.11 | DisplayString | read-write | Site Country |
| STR upsIdentContactName | 1.3.6.1.4.1.7309.6.1.1.12 | DisplayString | read-write | Contact Name |
| STR upsIdentPhoneNumber | 1.3.6.1.4.1.7309.6.1.1.13 | DisplayString | read-write | Phone Number |
| STR upsIdentDate | 1.3.6.1.4.1.7309.6.1.1.14 | DisplayString | read-write | Date of the RMU-Novus |
| STR upsIdentTime | 1.3.6.1.4.1.7309.6.1.1.15 | DisplayString | read-write | Time of the RMU-Novus |
| upsBattery | 1.3.6.1.4.1.7309.6.1.2 | | | |
| INT upsBatteryStatus | 1.3.6.1.4.1.7309.6.1.2.1 | INTEGER | read-only | The indication of the capacity remaining in the UPS
system's batteries. A value of batteryNormal
indicates that the remaining run-time is greater than
upsConfigLowBattTime. A value of batteryLow indicates
that the remaining battery run-time is less than or
equal to upsConfigLowBattTime. A value of
batteryDepleted indicates that the UPS will be unable
to sustain the present load when and if the utility
power is lost (including the possibility that the
utility power is currently absent and the UPS is
unable to sustain the output). |
| INT upsMinutesOnBattery | 1.3.6.1.4.1.7309.6.1.2.2 | INTEGER | read-only | The accumulated elapsed time that the UPS system have been on battery. |
| INT upsBatteryVoltage | 1.3.6.1.4.1.7309.6.1.2.3 | INTEGER | read-only | The magnitude of the present battery voltage. |
| INT upsBatteryChargingCurrent | 1.3.6.1.4.1.7309.6.1.2.4 | INTEGER | read-only | The present battery charging current. |
| INT upsBatteryCapacity | 1.3.6.1.4.1.7309.6.1.2.5 | INTEGER | read-only | The present battery capacity. |
| INT upsBatteryTemperature | 1.3.6.1.4.1.7309.6.1.2.6 | INTEGER | read-only | The ambient temperature at or near the UPS Battery
casing. |
| INT upsBatteryLowWarning | 1.3.6.1.4.1.7309.6.1.2.7 | INTEGER | read-write | The set battery capacity percentage at which the unit will raise an alarm. |
| upsInput | 1.3.6.1.4.1.7309.6.1.3 | | | |
| INT upsInputNumLines | 1.3.6.1.4.1.7309.6.1.3.1 | INTEGER | read-only | The number of input lines utilized in this device.
This variable indicates the number of rows in the
input table. |
| upsInputTable | 1.3.6.1.4.1.7309.6.1.3.2 | | not-accessible | A list of input table entries. The number of entries
is given by the value of upsInputNumLines. |
| upsInputEntry | 1.3.6.1.4.1.7309.6.1.3.2.1 | | not-accessible | An entry containing information applicable to a
particular input line. |
| INT upsInputLineIndex | 1.3.6.1.4.1.7309.6.1.3.2.1.1 | INTEGER | not-accessible | The input line identifier. |
| INT upsInputFrequency | 1.3.6.1.4.1.7309.6.1.3.2.1.2 | INTEGER | read-only | The present input frequency. |
| INT upsInputVoltage | 1.3.6.1.4.1.7309.6.1.3.2.1.3 | INTEGER | read-only | The magnitude of the present input voltage. |
| upsOutput | 1.3.6.1.4.1.7309.6.1.4 | | | |
| INT upsOutputSource | 1.3.6.1.4.1.7309.6.1.4.1 | INTEGER | read-only | The present source of output power. The enumeration
line(2) indicates that the Novus is in line mode. |
| INT upsOutputFrequency | 1.3.6.1.4.1.7309.6.1.4.2 | INTEGER | read-only | The present output frequency. |
| INT upsOutputNumLines | 1.3.6.1.4.1.7309.6.1.4.3 | INTEGER | read-only | The number of output lines utilized in this device.
This variable indicates the number of rows in the
output table. |
| upsOutputTable | 1.3.6.1.4.1.7309.6.1.4.4 | | not-accessible | A list of output table entries. The number of
entries is given by the value of upsOutputNumLines. |
| upsOutputEntry | 1.3.6.1.4.1.7309.6.1.4.4.1 | | not-accessible | An entry containing information applicable to a
particular output line. |
| INT upsOutputLineIndex | 1.3.6.1.4.1.7309.6.1.4.4.1.1 | INTEGER | not-accessible | The output line identifier. |
| INT upsOutputVoltage | 1.3.6.1.4.1.7309.6.1.4.4.1.2 | INTEGER | read-only | The present output voltage. |
| INT upsOutputCurrent | 1.3.6.1.4.1.7309.6.1.4.4.1.3 | INTEGER | read-only | The present output current. |
| INT upsOutputPowerVA | 1.3.6.1.4.1.7309.6.1.4.4.1.4 | INTEGER | read-only | The present output VA. |
| INT upsOutputPowerWatt | 1.3.6.1.4.1.7309.6.1.4.4.1.5 | INTEGER | read-only | The present output true power. |
| INT upsPowerFactor | 1.3.6.1.4.1.7309.6.1.4.4.1.6 | INTEGER | read-only | The present power factor. |
| INT upsOutputPercentLoad | 1.3.6.1.4.1.7309.6.1.4.4.1.7 | INTEGER | read-only | The percentage of the UPS power capacity presently
being used on this output line, i.e., the greater of
the percent load of true power capacity and the
percent load of VA. |
| upsAlarm | 1.3.6.1.4.1.7309.6.1.5 | | | |
| INT upsAlarmsPresent | 1.3.6.1.4.1.7309.6.1.5.1 | INTEGER | read-only | The present number of active alarm conditions. |
| upsAlarmTable | 1.3.6.1.4.1.7309.6.1.5.2 | | not-accessible | A list of alarm table entries. |
| upsAlarmEntry | 1.3.6.1.4.1.7309.6.1.5.2.1 | | not-accessible | An entry containing information applicable to a
particular alarm. |
| INT upsAlarmId | 1.3.6.1.4.1.7309.6.1.5.2.1.1 | INTEGER | not-accessible | A unique identifier for an alarm condition. This
value must remain constant. |
| STR upsAlarmDescr | 1.3.6.1.4.1.7309.6.1.5.2.1.2 | DisplayString | read-only | A unique description of the alarm. |
| INT upsAlarmStatus | 1.3.6.1.4.1.7309.6.1.5.2.1.3 | INTEGER | read-only | 1 - ON or 0 - OFF. |
| upsConfig | 1.3.6.1.4.1.7309.6.1.6 | | | |
| INT upsConfigLineQualifyTime | 1.3.6.1.4.1.7309.6.1.6.1 | INTEGER | read-only | This objects displays the line qualify time. |
| INT upsConfigLineOutputVoltageHighLimit | 1.3.6.1.4.1.7309.6.1.6.2 | INTEGER | read-only | This object represents the Line output High Voltage Limit. |
| INT upsConfigLineOutputVoltageLowLimit | 1.3.6.1.4.1.7309.6.1.6.3 | INTEGER | read-only | This object represents the Line output Low Voltage Limit. |
| INT upsConfigFanOnTemperature | 1.3.6.1.4.1.7309.6.1.6.4 | INTEGER | read-only | This object represents the Fan on temperature. |
| INT upsShutdownStatus | 1.3.6.1.4.1.7309.6.1.6.5 | INTEGER | read-write | This object tells us if output is disabled or enabled. |
| INT upsInverterOffDelayTime | 1.3.6.1.4.1.7309.6.1.6.6 | INTEGER | read-write | This object represents the inverter off delay time. |
| STR upsConfigIPAddress | 1.3.6.1.4.1.7309.6.1.6.7 | DisplayString | read-write | This objects displays the IP address of the RMU. |
| STR upsConfigNetMask | 1.3.6.1.4.1.7309.6.1.6.8 | DisplayString | read-write | This object displays the Net Mask of the RMU. |
| STR upsConfigGateway | 1.3.6.1.4.1.7309.6.1.6.9 | DisplayString | read-write | This object displays the Gateway of the RMU. |
| STR upsConfigSnmpTrapIPDestination | 1.3.6.1.4.1.7309.6.1.6.11 | DisplayString | read-write | This object displays the SNMP Trap IP destination. |
| upsTraps | 1.3.6.1.4.1.7309.6.1.7 | | | |
| upsTrap | 1.3.6.1.4.1.7309.6.1.7.0 | | | |
| NTF upsAlarmTrap | 1.3.6.1.4.1.7309.6.1.7.0.1 | | | A trap issued from a change in state in one of the Alarms on the Novus controller |
| NTF upsAgentStartupTrap | 1.3.6.1.4.1.7309.6.1.7.0.2 | | | A trap to indicate that the agent software has started up. |
| NTF upsAgentShutdownTrap | 1.3.6.1.4.1.7309.6.1.7.0.3 | | | A trap to indicate that the agent software has shutdown. |
| NTF upsAgentFaultTrap | 1.3.6.1.4.1.7309.6.1.7.0.4 | | | A trap issued from a change in state in one of the Faults on the Novus controller |
| NTF upsAgentEventTrap | 1.3.6.1.4.1.7309.6.1.7.0.5 | | | A trap issued from a change in state in one of the Events on the Novus controller |