BLDG-HVAC-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › BLDG-HVAC-MIB

Organization: SNMPCONF working group E-mail: snmpconf@snmp.com

Last Updated: 2003-03-27

Category: Hardware and Environment

Description: Monitors and manages building HVAC (heating, ventilation, and air conditioning) system parameters via SNMP.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is BLDG-HVAC-MIB?

BLDG-HVAC-MIB is an IETF example/standards-track MIB (RFC 3512) illustrating how to model building HVAC (heating, ventilation, and air conditioning) systems and room-level climate policies over SNMP. It exposes a table of HVAC zones keyed by floor and office, including configuration templates, fan speed, current temperature readings, and cumulative cooling/heating run-time minutes. As an environmental-monitoring MIB it is explicitly used to track physical facility conditions rather than network hardware, letting an operator monitor current room temperature, fan operation, and how long heating or cooling has been running, which flags HVAC faults or comfort-policy violations (e.g., a room stuck too hot with the fan off). It depends on standard SNMPv2 SMI conventions including StorageType and RowStatus for row lifecycle management, per general IETF conventions rather than any device-specific MIB. It is deployed in building management systems monitoring facility climate control equipment, sometimes co-located with a data center's environmental monitoring alongside network gear. Engineers implementing or auditing this functionality typically reference the BLDG-HVAC-MIB RFC/standard documentation for the authoritative specification.

IPNetwork Monitor allows you to monitor SNMP objects defined in BLDG-HVAC-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • vendor-neutral, standards-based MIB, not tied to a specific manufacturer
  • building HVAC control unit / building management system

Monitoring Examples

An admin would poll bldgHVACTable/bldgHVACEntry indexed by bldgHVACFloor and bldgHVACOffice to read bldgHVACCurrentTemp and bldgHVACFanSpeed for a given room, comparing against the bldgHVACCfgTemplate policy. If bldgHVACCurrentTemp is far outside the template's target range while bldgHVACCoolOrHeatMins keeps climbing, that indicates the HVAC unit is running continuously without reaching setpoint, signaling a mechanical fault. bldgHVACStatus and bldgHVACStorageType would be checked to confirm the row is active and its configuration is persistent versus volatile.

What Can Be Monitored

  • current room temperature
  • fan speed
  • cooling/heating run-time minutes
  • HVAC configuration template
  • zone row status
Imported Objects

From SNMP-FRAMEWORK-MIB

SnmpAdminString

From SNMPv2-CONF

MODULE-COMPLIANCE
OBJECT-GROUP

From SNMPv2-SMI

Counter32
Gauge32
MODULE-IDENTITY
OBJECT-TYPE
Unsigned32
experimental

From SNMPv2-TC

RowStatus
StorageType
TEXTUAL-CONVENTION
TimeStamp

How to Use in IPNetwork Monitor

Example using bldgHVACCoolOrHeatMins OID:

Select a Building HVAC control units/BM as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type bldgHVACCoolOrHeatMins into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of heating or cooling minutes that have been consumed since the row was activated. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline (in minutes), since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

SNMP management for building heating, ventilation, and air conditioning systems with policy-based room configuration.