| OID symbolic | OID numeric | Type | Access | Description |
| hh3cTransceiver | 1.3.6.1.4.1.25506.2.70 | | | The objects in this MIB module are used to display the
information of transceiver on interface. |
| hh3cTransceiverInfoAdm | 1.3.6.1.4.1.25506.2.70.1 | | | |
| hh3cTransceiverInfoTable | 1.3.6.1.4.1.25506.2.70.1.1 | | not-accessible | This table shows transceiver information on an interface. |
| hh3cTransceiverInfoEntry | 1.3.6.1.4.1.25506.2.70.1.1.1 | | not-accessible | The entry of the hh3cTransceiverInfoTable. |
| OCT hh3cTransceiverHardwareType | 1.3.6.1.4.1.25506.2.70.1.1.1.1 | OCTET STRING | read-only | Hardware type of the interface, such as SM(single mode). |
| OCT hh3cTransceiverType | 1.3.6.1.4.1.25506.2.70.1.1.1.2 | OCTET STRING | read-only | Type of the interface, such as SFP/XFP/GBIC. |
| I32 hh3cTransceiverWaveLength | 1.3.6.1.4.1.25506.2.70.1.1.1.3 | Integer32 | read-only | Wave length of the interface, measured in nanometer. |
| OCT hh3cTransceiverVendorName | 1.3.6.1.4.1.25506.2.70.1.1.1.4 | OCTET STRING | read-only | Vendor name of the interface. |
| OCT hh3cTransceiverSerialNumber | 1.3.6.1.4.1.25506.2.70.1.1.1.5 | OCTET STRING | read-only | Serial number of the interface. |
| INT hh3cTransceiverFiberDiameterType | 1.3.6.1.4.1.25506.2.70.1.1.1.6 | INTEGER | read-only | The diameter of the fiber, measured in micron.
fiber9 - 9 micron multi-mode fiber
fiber50 - 50 micron multi-mode fiber
fiber625 - 62.5 micron multi-mode fiber
copper - copper cable. |
| I32 hh3cTransceiverTransferDistance | 1.3.6.1.4.1.25506.2.70.1.1.1.7 | Integer32 | read-only | The maximum distance which the interface can transmit,
measured in meter. |
| T/F hh3cTransceiverDiagnostic | 1.3.6.1.4.1.25506.2.70.1.1.1.8 | TruthValue | read-only | Indicating the digital diagnostic monitoring function. |
| I32 hh3cTransceiverCurTXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.9 | Integer32 | read-only | Indicating the current transmitted power.
The unit is in hundredths of dBM. |
| I32 hh3cTransceiverMaxTXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.10 | Integer32 | read-only | Indicating the maximum transmitted power.
The unit is in hundredths of dBM. |
| I32 hh3cTransceiverMinTXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.11 | Integer32 | read-only | Indicating the minimum transmitted power.
The unit is in hundredths of dBM. |
| I32 hh3cTransceiverCurRXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.12 | Integer32 | read-only | Indicating the current received power.
The unit is in hundredths of dBM. |
| I32 hh3cTransceiverMaxRXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.13 | Integer32 | read-only | Indicating the maximum received power.
The unit is in hundredths of dBM. |
| I32 hh3cTransceiverMinRXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.14 | Integer32 | read-only | Indicating the minimum received power.
The unit is in hundredths of dBM. |
| I32 hh3cTransceiverTemperature | 1.3.6.1.4.1.25506.2.70.1.1.1.15 | Integer32 | read-only | Indicating the current temperature.
The unit is Celsius centigrade. |
| I32 hh3cTransceiverVoltage | 1.3.6.1.4.1.25506.2.70.1.1.1.16 | Integer32 | read-only | Indicating the current voltage.
The unit is in hundredths of V |
| I32 hh3cTransceiverBiasCurrent | 1.3.6.1.4.1.25506.2.70.1.1.1.17 | Integer32 | read-only | Indicating the current bias electric current.
The unit is in hundredths of mA |
| I32 hh3cTransceiverTempHiAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.18 | Integer32 | read-only | Transceiver temperature high alarm threshold
limit in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius. |
| I32 hh3cTransceiverTempLoAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.19 | Integer32 | read-only | Transceiver temperature low alarm threshold
limit in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius. |
| I32 hh3cTransceiverTempHiWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.20 | Integer32 | read-only | Transceiver temperature high warning threshold
limit in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius. |
| I32 hh3cTransceiverTempLoWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.21 | Integer32 | read-only | Transceiver temperature low warning threshold
limit in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius. |
| I32 hh3cTransceiverVccHiAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.22 | Integer32 | read-only | Transceiver VCC high alarm threshold
limit in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver. |
| I32 hh3cTransceiverVccLoAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.23 | Integer32 | read-only | Transceiver VCC low alarm threshold
limit in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver. |
| I32 hh3cTransceiverVccHiWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.24 | Integer32 | read-only | Transceiver VCC high warning threshold
limit in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver. |
| I32 hh3cTransceiverVccLoWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.25 | Integer32 | read-only | Transceiver VCC low warning threshold
limit in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver. |
| I32 hh3cTransceiverBiasHiAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.26 | Integer32 | read-only | Transceiver bias high alarm threshold limit in microamps. |
| I32 hh3cTransceiverBiasLoAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.27 | Integer32 | read-only | Transceiver bias low alarm threshold limit in microamps. |
| I32 hh3cTransceiverBiasHiWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.28 | Integer32 | read-only | Transceiver bias high warning threshold limit in microamps. |
| I32 hh3cTransceiverBiasLoWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.29 | Integer32 | read-only | Transceiver bias low warning threshold limit in microamps. |
| I32 hh3cTransceiverPwrOutHiAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.30 | Integer32 | read-only | Transceiver transmit power high alarm
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| I32 hh3cTransceiverPwrOutLoAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.31 | Integer32 | read-only | Transceiver transmit power low alarm
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| I32 hh3cTransceiverPwrOutHiWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.32 | Integer32 | read-only | Transceiver transmit power high warning
threshold limit in tenths of microwatts
As an example: 10000 is 1 milliwatt. |
| I32 hh3cTransceiverPwrOutLoWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.33 | Integer32 | read-only | Transceiver transmit power low warning
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| I32 hh3cTransceiverRcvPwrHiAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.34 | Integer32 | read-only | Transceiver receive power high alarm
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| I32 hh3cTransceiverRcvPwrLoAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.35 | Integer32 | read-only | Transceiver receive power low alarm
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| I32 hh3cTransceiverRcvPwrHiWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.36 | Integer32 | read-only | Transceiver receive power high warning
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| I32 hh3cTransceiverRcvPwrLoWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.37 | Integer32 | read-only | Transceiver receive power low warning
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| BIT hh3cTransceiverErrors | 1.3.6.1.4.1.25506.2.70.1.1.1.38 | Bits | read-only | Bitmask indicating transceiver errors.
Transceiver information I/O error(0)
Transceiver information checksum error(1)
Transceiver type and port configuration mismatch(2)
Transceiver type not supported by port hardware(3)
WIS local fault(4)
Receive optical power fault(5)
PMA/PMD receiver local fault(6)
PCS receive local fault(7)
PHY XS receive local fault(8)
Laser bias current fault(9)
Laser temperature fault(10)
Laser output power fault(11)
TX fault(12)
PMA/PMD transmitter local fault(13)
PCS transmit local fault(14)
PHY XS Transmit Local Fault(15)
RX loss of signal(16)
Unused(17-31) |
| OCT hh3cTransceiverVendorOUI | 1.3.6.1.4.1.25506.2.70.1.1.1.39 | OCTET STRING | read-only | Vendor OUI of the interface. |
| OCT hh3cTransceiverRevisionNumber | 1.3.6.1.4.1.25506.2.70.1.1.1.40 | OCTET STRING | read-only | Revision number of the interface. |
| hh3cTransceiverChannelTable | 1.3.6.1.4.1.25506.2.70.1.2 | | not-accessible | This table provides statistics about transceiver with multi-channel. |
| hh3cTransceiverChannelEntry | 1.3.6.1.4.1.25506.2.70.1.2.1 | | not-accessible | The entry of the hh3cTransceiverChannelTable. |
| I32 hh3cTransceiverChannelIndex | 1.3.6.1.4.1.25506.2.70.1.2.1.1 | Integer32 | not-accessible | The channel index of transceiver.
Indicating one channel of the interface. |
| I32 hh3cTransceiverChannelCurTXPower | 1.3.6.1.4.1.25506.2.70.1.2.1.2 | Integer32 | read-only | Indicating the current transmission power.
The unit is in hundredths of dBM. |
| I32 hh3cTransceiverChannelCurRXPower | 1.3.6.1.4.1.25506.2.70.1.2.1.3 | Integer32 | read-only | Indicating the current received power.
The unit is in hundredths of dBM. |
| I32 hh3cTransceiverChannelTemperature | 1.3.6.1.4.1.25506.2.70.1.2.1.4 | Integer32 | read-only | Indicating the current temperature.
The unit is Celsius centigrade. |
| I32 hh3cTransceiverChannelBiasCurrent | 1.3.6.1.4.1.25506.2.70.1.2.1.5 | Integer32 | read-only | Indicating the current bias electric current.
The unit is in hundredths of mA. |