| OID symbolic | OID numeric | Type | Access | Description |
| accessEntry | 1.3.6.1.4.1.17420.1.1.999.1.1.1 | | not-accessible | |
| INT accessNo | 1.3.6.1.4.1.17420.1.1.999.1.1.1.1 | INTEGER | read-only | |
| accessTable | 1.3.6.1.4.1.17420.1.1.999.1.1 | | not-accessible | |
| ats | 1.3.6.1.4.1.17420.1.1.5 | | | |
| INT atsAutomaticTransferSwitch | 1.3.6.1.4.1.17420.1.1.5.4 | INTEGER | read-write | |
| STR atsIdentification | 1.3.6.1.4.1.17420.1.1.5.1 | DisplayString | read-write | |
| STR atsInputPowerSourceA | 1.3.6.1.4.1.17420.1.1.5.2 | DisplayString | read-write | |
| STR atsInputPowerSourceB | 1.3.6.1.4.1.17420.1.1.5.3 | DisplayString | read-write | |
| INT atsStatus | 1.3.6.1.4.1.17420.1.1.5.5 | INTEGER | read-only | |
| cps | 1.3.6.1.4.1.17420.1.1.4 | | | |
| NTF cpsCommunicationLost | 1.3.6.1.4.1.17420.0.107 | | | CRITICAL: CPS Communication lost. |
| cpsEntry | 1.3.6.1.4.1.17420.1.1.4.2.1 | | not-accessible | An entry containing information of an cps. |
| INT cpsID | 1.3.6.1.4.1.17420.1.1.4.2.1.1 | INTEGER | read-only | The ID number of cps. |
| INT cpsIDIndex | 1.3.6.1.4.1.17420.1.1.4.3.1.1 | INTEGER | read-only | The ID number of cps. |
| INT cpsNumber | 1.3.6.1.4.1.17420.1.1.4.1 | INTEGER | read-only | Indicate how many cps attached to this system. |
| NTF cpsOutOfThreshold1 | 1.3.6.1.4.1.17420.0.105 | | | WARNING: CPS current out of threshold 1. |
| NTF cpsOutOfThreshold2 | 1.3.6.1.4.1.17420.0.106 | | | CRITICAL: CPS current out of threshold 2. |
| cpsSetEntry | 1.3.6.1.4.1.17420.1.1.4.3.1 | | not-accessible | An entry containing information of an cps. |
| cpsSetTable | 1.3.6.1.4.1.17420.1.1.4.3 | | not-accessible | The number of entries is contained in the cpsNumber OID. |
| INT cpsSetThreshold1 | 1.3.6.1.4.1.17420.1.1.4.3.1.2 | INTEGER | read-write | Set current threshold 1. |
| INT cpsSetThreshold2 | 1.3.6.1.4.1.17420.1.1.4.3.1.3 | INTEGER | read-write | Set current threshold 2. |
| cpsTable | 1.3.6.1.4.1.17420.1.1.4.2 | | not-accessible | The number of entries is contained in the cpsNumber OID. |
| INT cpsThreshold1 | 1.3.6.1.4.1.17420.1.1.4.2.1.3 | INTEGER | read-only | Indicate current threshold 1. |
| INT cpsThreshold2 | 1.3.6.1.4.1.17420.1.1.4.2.1.4 | INTEGER | read-only | Indicate current threshold 2. |
| INT cpsValue | 1.3.6.1.4.1.17420.1.1.4.2.1.2 | INTEGER | read-only | Indicate the current of cps detect. |
| dgp | 1.3.6.1.4.1.17420 | | | |
| hardware | 1.3.6.1.4.1.17420.1.1 | | | |
| mgmt | 1.3.6.1.4.1.17420.1.1.999 | | | |
| INT permission | 1.3.6.1.4.1.17420.1.1.999.1.1.1.3 | INTEGER | read-write | |
| products | 1.3.6.1.4.1.17420.1 | | | |
| INT protocol | 1.3.6.1.4.1.17420.1.1.1 | INTEGER | read-write | select protocol |
| rpm | 1.3.6.1.4.1.17420.1.1.3 | | | |
| INT rpmAllOnOff | 1.3.6.1.4.1.17420.1.1.3.3.4 | INTEGER | read-write | The all outlets on/off for the rpm.
0 for all outlets off, 1 for all outlets on |
| NTF rpmCommunicationLost | 1.3.6.1.4.1.17420.0.104 | | | SEVERE: Communication to the UPS has been lost. Steps to reestablish communication are in progress. |
| STR rpmControlType | 1.3.6.1.4.1.17420.1.1.3.2.1.4 | DisplayString | read-write | Getting this OID will cause the status of all outlets to be
returned.
The format of the data returned is a character string consisting of a character from '0' to '2'.
'0' if the outlet is instant shutdown.
'1' if the outlet is safe shutdown.
'2' if the outlet is safe reboot.
A comma character will delimit each outlet entry in the string.
For exampe:
If the returned string is '1,2,0,1', it means the iSwith has 4 outlets and
the outlets status are the following:
outlet 1 is safe shutdown,
outlet 2 is safe reboot,
outlet 3 is instant shutdown,
outlet 4 is safe shutdown. |
| STR rpmDate | 1.3.6.1.4.1.17420.1.1.3.4.1.6 | DisplayString | read-write | The shutdown date. |
| INT rpmDelayA | 1.3.6.1.4.1.17420.1.1.3.2.1.15 | INTEGER | read-write | |
| INT rpmDelayB | 1.3.6.1.4.1.17420.1.1.3.2.1.16 | INTEGER | read-write | |
| INT rpmDelayC | 1.3.6.1.4.1.17420.1.1.3.2.1.17 | INTEGER | read-write | |
| INT rpmDelayD | 1.3.6.1.4.1.17420.1.1.3.2.1.18 | INTEGER | read-write | |
| INT rpmDelayE | 1.3.6.1.4.1.17420.1.1.3.2.1.19 | INTEGER | read-write | |
| INT rpmDelayF | 1.3.6.1.4.1.17420.1.1.3.2.1.20 | INTEGER | read-write | |
| INT rpmDelayG | 1.3.6.1.4.1.17420.1.1.3.2.1.21 | INTEGER | read-write | |
| INT rpmDelayH | 1.3.6.1.4.1.17420.1.1.3.2.1.22 | INTEGER | read-write | |
| rpmEntry | 1.3.6.1.4.1.17420.1.1.3.2.1 | | not-accessible | An entry containing information of an rpm. |
| INT rpmID | 1.3.6.1.4.1.17420.1.1.3.2.1.1 | INTEGER | read-only | The ID number of rpm. |
| STR rpmInternetLocal | 1.3.6.1.4.1.17420.1.1.3.2.1.5 | DisplayString | read-write | Getting this OID will cause the status of all outlets to be
returned.
The format of the data returned is a character string consisting of a character from '0' to '1'.
'0' if the outlet is Internet.
'1' if the outlet is Local.
A comma character will delimit each outlet entry in the string.
For exampe:
If the returned string is '1,1,0,1', it means the iSwith has 4 outlets and
the outlets status are the following:
outlet 1 is Local,
outlet 2 is Local,
outlet 3 is Internet,
outlet 4 is Local. |
| STR rpmName | 1.3.6.1.4.1.17420.1.1.3.2.1.6 | DisplayString | read-write | |
| INT rpmNumber | 1.3.6.1.4.1.17420.1.1.3.1 | INTEGER | read-only | Indicate how many rpm attached to this system. |
| INT rpmOffNumber | 1.3.6.1.4.1.17420.1.1.3.3.3 | INTEGER | read-write | The off number of outlets for the rpm. |
| INT rpmOnNumber | 1.3.6.1.4.1.17420.1.1.3.3.2 | INTEGER | read-write | The on number of outlets for the rpm. |
| INT rpmOutlet | 1.3.6.1.4.1.17420.1.1.3.4.1.3 | INTEGER | read-write | The specified outlet in rpm. |
| STR rpmOutletA | 1.3.6.1.4.1.17420.1.1.3.2.1.7 | DisplayString | read-write | |
| INT rpmOutletAction | 1.3.6.1.4.1.17420.1.1.3.4.1.4 | INTEGER | read-write | On/Off schedule entry. |
| STR rpmOutletB | 1.3.6.1.4.1.17420.1.1.3.2.1.8 | DisplayString | read-write | |
| STR rpmOutletC | 1.3.6.1.4.1.17420.1.1.3.2.1.9 | DisplayString | read-write | |
| STR rpmOutletD | 1.3.6.1.4.1.17420.1.1.3.2.1.10 | DisplayString | read-write | |
| STR rpmOutletE | 1.3.6.1.4.1.17420.1.1.3.2.1.11 | DisplayString | read-write | |
| STR rpmOutletF | 1.3.6.1.4.1.17420.1.1.3.2.1.12 | DisplayString | read-write | |
| NTF rpmOutletfault | 1.3.6.1.4.1.17420.0.103 | | | SEVERE: The specified rpm outlet has fault. |
| STR rpmOutletG | 1.3.6.1.4.1.17420.1.1.3.2.1.13 | DisplayString | read-write | |
| STR rpmOutletH | 1.3.6.1.4.1.17420.1.1.3.2.1.14 | DisplayString | read-write | |
| INT rpmOutletNumber | 1.3.6.1.4.1.17420.1.1.3.2.1.2 | INTEGER | read-only | The number of outlets for the rpm. |
| NTF rpmOutletOff | 1.3.6.1.4.1.17420.0.101 | | | WARNING: The specified RPM outlet has turned off. |
| NTF rpmOutletOn | 1.3.6.1.4.1.17420.0.100 | | | WARNING: The specified RPM outlet has turned on. |
| NTF rpmOutletReboot | 1.3.6.1.4.1.17420.0.102 | | | WARNING: The specified RPM outlet has rebooted. |
| STR rpmOutletState | 1.3.6.1.4.1.17420.1.1.3.2.1.3 | DisplayString | read-only | Getting this OID will cause the status of all outlets to be
returned. This OID is provided for informational purposes only.
The format of the data returned is a character string consisting of a character from '0' to '3'.
'0' if the outlet is off.
'1' if the outlet is on.
'2' if the outlet is in shutdown pending state.
'3' if the outlet is fault.
A comma character will delimit each outlet entry in the string.
For exampe:
If the returned string is '1,2,0,3', it means the iSwith has 4 outlets and
the outlets status are the following:
outlet 1 is on,
outlet 2 is in shutdown pending state,
outlet 3 is off,
outlet 4 is fault. |
| INT rpmPeriod | 1.3.6.1.4.1.17420.1.1.3.4.1.5 | INTEGER | read-write | The period of shutdown. |
| INT rpmResumeDelayA | 1.3.6.1.4.1.17420.1.1.3.2.1.23 | INTEGER | read-write | |
| INT rpmResumeDelayB | 1.3.6.1.4.1.17420.1.1.3.2.1.24 | INTEGER | read-write | |
| INT rpmResumeDelayC | 1.3.6.1.4.1.17420.1.1.3.2.1.25 | INTEGER | read-write | |
| INT rpmResumeDelayD | 1.3.6.1.4.1.17420.1.1.3.2.1.26 | INTEGER | read-write | |
| INT rpmResumeDelayE | 1.3.6.1.4.1.17420.1.1.3.2.1.27 | INTEGER | read-write | |
| INT rpmResumeDelayF | 1.3.6.1.4.1.17420.1.1.3.2.1.28 | INTEGER | read-write | |
| INT rpmResumeDelayG | 1.3.6.1.4.1.17420.1.1.3.2.1.29 | INTEGER | read-write | |
| INT rpmResumeDelayH | 1.3.6.1.4.1.17420.1.1.3.2.1.30 | INTEGER | read-write | |
| rpmScheduleEntry | 1.3.6.1.4.1.17420.1.1.3.4.1 | | not-accessible | An entry containing information of an rpm. |
| INT rpmScheduleID | 1.3.6.1.4.1.17420.1.1.3.4.1.2 | INTEGER | read-write | The Schedule shutdown ID number of rpm. |
| INT rpmScheduleIndex | 1.3.6.1.4.1.17420.1.1.3.4.1.1 | INTEGER | read-only | |
| rpmScheduleTable | 1.3.6.1.4.1.17420.1.1.3.4 | | not-accessible | |
| rpmSetEntry | 1.3.6.1.4.1.17420.1.1.3.3 | | | |
| INT rpmSetID | 1.3.6.1.4.1.17420.1.1.3.3.1 | INTEGER | read-write | The ID number of rpm. |
| INT rpmStatus | 1.3.6.1.4.1.17420.1.1.3.4.1.8 | INTEGER | read-write | Accept/Clear schedule entry. |
| rpmTable | 1.3.6.1.4.1.17420.1.1.3.2 | | not-accessible | The number of entries is contained in the rpmNumber OID. |
| STR rpmTime | 1.3.6.1.4.1.17420.1.1.3.4.1.7 | DisplayString | read-write | The shutdown time. |
| snmp | 1.3.6.1.4.1.17420.1.1.999.1 | | | |