All MIBs › FH800u-MIB
Category: Device Management, Hardware and Environment
Description: Vendor-specific MIB for FH800u series network equipment providing device management and interface status monitoring.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is FH800u-MIB?
FH800u-MIB is a legacy Allied Telesis (enterprise OID 207, Dual-Speed Hub) proprietary MIB reporting stack IP addressing and hub-group hardware inventory. Its objects cover in-use/temporal IP address/netmask/gateway/server-SLIP/host-SLIP/boot-up-IP pairs, an IP-information-reset action, a stack health-monitor flag, and a group table (ID, type, counter-reset action, position, repeater hardware version, serial number, system major/minor version, POST-code major version). As a status/configuration MIB it lets an administrator confirm stack IP addressing and hub-group hardware inventory on a legacy Allied Telesis Dual-Speed Hub stack. It is deployed on legacy Allied Telesis Dual-Speed Hub (FH800u) equipment. Engineers can download the FH800u-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in FH800u-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Legacy Allied Telesis Dual-Speed Hub (FH800u) equipment
Monitoring Examples
An administrator checks stackInusedIP and groupRptrHwVer to confirm stack IP addressing and hub hardware revision on a legacy Allied Telesis Dual-Speed Hub.
What Can Be Monitored
- stack IP addressing and hub-group hardware inventory
This MIB depends on
Related MIBs
Imported Objects
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| OBJECT-TYPE | |
| TimeTicks | |
| enterprises |
From RFC1213-MIB
| DisplayString | |
| PhysAddress |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| acctonHubMIB | 1.3.6.1.4.1.207.8.1.20.3 | |||
| alliedTelesyn | 1.3.6.1.4.1.207 | |||
| atactDualHubMgt | 1.3.6.1.4.1.207.8.1.20.3.11 | |||
| dualHub | 1.3.6.1.4.1.207.1.10 | |||
| fh800uBasicCapability | 1.3.6.1.4.1.207.8.1.20.3.11.1.1 | |||
| fh800uGroupInfo | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2 | |||
| NTF fh800uIntrusionHappen | 1.3.6.1.4.1.207.8.1.20.3.11.0.1 | There were some intruders on some port in this system | ||
| fh800uMgt | 1.3.6.1.4.1.207.8.1.20.3.11.1 | |||
| fh800uPerfMonCapability | 1.3.6.1.4.1.207.8.1.20.3.11.1.2 | |||
| fh800uPerfMonSegmentInfo | 1.3.6.1.4.1.207.8.1.20.3.11.1.2.3 | |||
| fh800uPortInfo | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.3 | |||
| fh800uRmonConfig | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.5 | |||
| fh800uSecurityCapability | 1.3.6.1.4.1.207.8.1.20.3.11.1.5 | |||
| fh800uSecurityInfo | 1.3.6.1.4.1.207.8.1.20.3.11.1.5.3 | |||
| fh800uSegmentInfo | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.4 | |||
| fh800uStackInfo | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1 | |||
| fh800uSwitchCapability | 1.3.6.1.4.1.207.8.1.20.3.11.1.3 | |||
| fh800uSwitchStatsInfo | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1 | |||
| fh812u | 1.3.6.1.4.1.207.1.10.1 | |||
| fh824u | 1.3.6.1.4.1.207.1.10.2 | |||
| INT fullRmonSegment | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.5.2 | INTEGER | read-write | The value shows if the segment supports all rmon or only 4 rmon groups. |
| INT groupAgentBaudrate | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.16 | INTEGER | read-write | Baud rate of the console port |
| INT groupAgentBootupOption | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.15 | INTEGER | read-write | This variable defines how to start the microcode in the segment. normal(1): Use NVRAM information and flash ROM microcode to start up the system. tftp-download(2): Always download the new version of microcode into RAM and start it. bootp-get-ip(3): Get the IP information from the BootP server, and then start up the microcode in flash ROM. bootp-download(4): Get the IP information from the BootP server, and then download the microcode from the TFTP server. bootp-upgrade(5): Get the IP information from the BootP server, and then download the microcode from the TFTP server. After the download has been completed, upgrade the microcode in system flash ROM. |
| INT groupAgentHwVer | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.12 | INTEGER | read-only | Hardware version of the agent board. |
| PHY groupAgentPhysAddr | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.14 | PhysAddress | read-only | MAC address of this hub agent |
| PHY groupAgentSerialNo | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.13 | PhysAddress | read-only | Serial number of the agent board. |
| INT groupAgentStatus | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.11 | INTEGER | read-only | Status of this hub agent. Each stack allows an SNMP primary agent. primary(2): The agent in this stack is a primary agent. backup(3): The agent in this stack is a backup agent. |
| INT groupCounterReset | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.3 | INTEGER | read-write | Write any value to this variable to reset the counters of the hub unit. 2 is a value commonly used to reset things |
| groupEntry | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1 | not-accessible | ||
| INT groupID | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.1 | INTEGER | read-only | The ID number of a hub unit, used to select it |
| INT groupPosition | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.4 | INTEGER | read-only | Physical position of a hub unit in top-down order, only supported if hardware permits such as Dual-Speed Hub systems |
| INT groupPostCodeMajorVer | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.9 | INTEGER | read-only | POST microcode major version of this hub. |
| INT groupPostCodeMinorVer | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.10 | INTEGER | read-only | POST microcode minor version of this hub. |
| INT groupRptrHwVer | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.5 | INTEGER | read-only | Hardware version of the repeater board. |
| PHY groupRptrSerialNo | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.6 | PhysAddress | read-only | Serial number of the repeater board. |
| INT groupSysMajorVer | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.7 | INTEGER | read-only | Microcode major version of this hub. |
| INT groupSysMinorVer | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.8 | INTEGER | read-only | Microcode minor version of this hub. |
| groupTable | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1 | not-accessible | A group means a hub unit | |
| INT groupType | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.2.1.1.2 | INTEGER | read-only | Type of hub unit |
| INT ipInformationReset | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.13 | INTEGER | read-write | Setting the stackIP, stackNetMask,stackGateway, stackSlipAddr, and stackBootUpIP will not immediately enable parameters take effect . They will take effect when ipInformationReset is set to reset(2). |
| mibObject | 1.3.6.1.4.1.207.8 | |||
| newRepeaterMib | 1.3.6.1.4.1.207.8.1.20 | |||
| INT nicAttachSegment | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.5.1 | INTEGER | read-write | The value represents the segment that the NIC is attached to. |
| perfMonSegmentEntry | 1.3.6.1.4.1.207.8.1.20.3.11.1.2.3.1.1 | not-accessible | ||
| perfMonSegmentTable | 1.3.6.1.4.1.207.8.1.20.3.11.1.2.3.1 | not-accessible | ||
| portEntry | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.3.1.1 | not-accessible | ||
| INT portGroupID | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.3.1.1.1 | INTEGER | read-only | ID of the hub unit |
| INT portID | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.3.1.1.2 | INTEGER | read-only | ID of the port unit |
| INT portSegmtID | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.3.1.1.5 | INTEGER | read-only | ID of the Segment unit |
| INT portSpeed | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.3.1.1.3 | INTEGER | read-only | Ethernet connector type of a port |
| INT portSpeedConfig | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.3.1.1.4 | INTEGER | read-write | Select the Ethernet connector type of a port |
| portTable | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.3.1 | not-accessible | information about ports in a system. Each port belongs to a group. | |
| products | 1.3.6.1.4.1.207.1 | |||
| repeaterMib | 1.3.6.1.4.1.207.8.1 | |||
| rmonConfigEntry | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.5.3.1 | not-accessible | ||
| INT rmonConfigSegmtID | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.5.3.1.1 | INTEGER | read-only | ID of the Segment rmon is montioring. |
| INT rmonConfigStatus | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.5.3.1.2 | INTEGER | read-write | Status of this RMON segment. |
| rmonConfigTable | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.5.3 | not-accessible | RMON configuration table information; the index is the ID of of the segment the rmon montioring . | |
| INT securityAutoLearnAction | 1.3.6.1.4.1.207.8.1.20.3.11.1.5.3.3.1.5 | INTEGER | read-write | Setting this object to inactive(1) disables the auto-learn function for the physical address authorized access to this port. Once this object is set to active(2), the agent will set the authorized address to 0 first and then start the auto-learn process, and the hub will begin to read the source address of the first incoming error-free frame. The source address obtained will become the authorized address and the object securityAuthorizedAddr will be changed accordingly. When the authorized address has been learned successfully, the status of this port will be reflected as learned(3). Otherwise the status will remain as active(2). Setting to the last value, learned(3), is not acceptable; 'snmpBadValue' will be returned. |
| PHY securityPortAddr | 1.3.6.1.4.1.207.8.1.20.3.11.1.5.3.3.1.3 | PhysAddress | read-write | MAC address |
| securityPortEntry | 1.3.6.1.4.1.207.8.1.20.3.11.1.5.3.3.1 | not-accessible | ||
| INT securityPortGroupID | 1.3.6.1.4.1.207.8.1.20.3.11.1.5.3.3.1.1 | INTEGER | read-only | ID of a hub unit |
| INT securityPortID | 1.3.6.1.4.1.207.8.1.20.3.11.1.5.3.3.1.2 | INTEGER | read-only | Port ID in a hub unit |
| INT securityPortIntrusion | 1.3.6.1.4.1.207.8.1.20.3.11.1.5.3.3.1.6 | INTEGER | read-write | Set this variable to set function active or inactive |
| securityPortTable | 1.3.6.1.4.1.207.8.1.20.3.11.1.5.3.3 | not-accessible | ||
| CTR segmentAlignmentErrors | 1.3.6.1.4.1.207.8.1.20.3.11.1.2.3.1.1.3 | Counter | read-only | Total frame alignment errors received by a segment |
| CTR segmentCollisions | 1.3.6.1.4.1.207.8.1.20.3.11.1.2.3.1.1.4 | Counter | read-only | Total collisions received in a segment |
| CTR segmentCRCErrors | 1.3.6.1.4.1.207.8.1.20.3.11.1.2.3.1.1.2 | Counter | read-only | Total CRC errors received by a segment. |
| INT segmentPerfID | 1.3.6.1.4.1.207.8.1.20.3.11.1.2.3.1.1.1 | INTEGER | read-only | ID used to select a segment |
| CTR segmentSymbolErrors | 1.3.6.1.4.1.207.8.1.20.3.11.1.2.3.1.1.6 | Counter | read-only | Total frame symbol errors received by a segment |
| CTR segmentTotalPortIsolates | 1.3.6.1.4.1.207.8.1.20.3.11.1.2.3.1.1.5 | Counter | read-only | Total isolated ports in a segment. |
| OCT stackHealthMonitor | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.14 | OCTET STRING | read-only | There are two kinds of hubs : 12 ports need (1+ 12 + 1 + 1 + 1 + 1 +1 +1 +1) 20 bytes and 24 ports need (1+ 24 + 1 + 1 + 1 + 1 +1 +1 +1) 32 bytes The maximun size : 256 bytes (total for 8 hubs)=8 hub * (1+ 24 + 1 + 1 + 1 +1 +1 +1 +1) bytes | byte256 byte255......................byte2 byte1 | bit7 bit6 ... bit1 bit0 Use the first byte of each hub to indicate whether 20 or 32 bytes is used. BYTE 1: total number of ports on a hub 00001100 : 12 ports | | bit7... bit0 00011000 : 24 ports | | bit7... bit0 For 12-port hub BYTE 2 - 13 : port status for port 1 - 12 *BYTE 2 : port status for port 1 bit 0-4 : LED status bit 0 : link status 0 - no link; 1 - link bit 1 : partition status 0 - no part.; 1 - part. bit 2 : port operation status 0 - disabled; 1 - enabled bit 3-4 : port type status 00 - not present 01 - tenMb 10 - onehundredMb 11 - reserved bit 5-7 : reserved BYTE 14-25 :reserved BYTE 26 : Expansion Port (EP) status1 bit 0-2: EP Type 000 - not present 100 - 100BASE-TX(ST) FEM 010 - 100BASE-TX(SC) FEM 1001 to 1111 - reserved bit 3-4 : FEM forwarding mode status Applicable only to FEM module 00 - adaptive cut through 01 - reserved 10 - reserved 11 - store and forward bit 5: FEM back pressure status 0 - disabled; 1 - enabled bit 6-7 : reserved BYTE 27 : Expansion Port (EP) status2 bit 0-1 : LED status bit 0 : FEM link status 0 - no link; 1 - link bit 1 : FEM half/full duplex status 0 - full duplex; 1 - half duplex bit 2 : EP collision led status 0 - off; 1 - on bit 3-4 : bit 3 : tx LED status 0 - off; 1 - tx on bit 4 : rx LED status 0 - off; 1 - rx on bit 5-7 : reserved BYTE 28 : tenMb segment traffic/collision bit 0-1 : tenMb traffic LED status 00 - no traffic 01 - low traffic 10 - middle traffic 11 - high traffic bit 2-5 : tenMb collision LED status 0000 - none 0001 - 1 % 0010 - 3 % 0011 - 5 % 0100 - 10 % 0101 - >= 15 % bit 6-7 : reserved BYTE 29 : onehundredMb segment traffic/collision /Power/Switch LED status bit 0-1 : onehundredMb traffic LED status 00 - no traffic 01 - low traffic 10 - middle traffic 11 - high traffic bit 2-5 : onehundredMb collision LED status 0000 - none 0001 - 1 % 0010 - 3 % 0011 - 5 % 0100 - 10 % 0101 - >= 15 % bit 6 : Power LED 0 - OFF; 1 - ON bit 7 : Switch LED 0 - OFF; 1 - ON BYTE 30 :SNMP agent & switch status bit 0: internal switch bit 0 - not exist; 1 - exist bit 1: internal switch status 0 - inactive; 1 - active bit 2: expension switch bit 0 - bad; 1 - good bit 3: expension switch status 0 - inactive; 1 - active bit 4: agent bit 0 - not exist; 1 - exist bit 5 : master status 0 - Slave; 1 - Master bit 6 - 7 : reserved BYTE 31 : Rmon status bit 0 : rmon bit 0 - not exist; 1 - exist bit 1 - 2 :rmon segment 00 - all stack 01 - segment tenMb 10 - segment onehundredMb 11 - reserved bit 3 - 5 : RMON group Status 000 - not-present 001 - disabled 010 - Rmon-4Group 011 - Rmon-7Group 100 - Rmon-all 101 to 111 - reserved bit 6 -7 : reserved BYTE 32 : Hub Position(Hub ID)/Bus Termination bit 0 - 3 : hub position 0000 - invalid 0001 - 1 0010 - 2 0011 - 3 0100 - 4 0101 - 5 0110 - 6 0111 - 7 1000 - 8 1001 to 1111 - reserved bit 4 : termination status 0 - not end hub 1 - end hub in the stack bit 5 - 7 : reserved For 24-port hub BYTE 2 - 25 : port status for port 1 - 24 *BYTE 2 : port status for port 1 bit 0-4 : LED status bit 0 : link status 0 - no link; 1 - link bit 1 : partition status 0 - no part.; 1 - part. bit 2 : port operation status 0 - disabled; 1 - enabled bit 3-4 : port type status 00 - not present 01 - tenMb 10 - onehundredMb 11 - reserved bit 5-7 : reserved BYTE 26 : Expansion Port (EP) status1 bit 0-2: EP Type 000 - not present 100 - 100BASE-TX(ST) FEM 010 - 100BASE-TX(SC) FEM 1001 to 1111 - reserved bit 3-4 : FEM forwarding mode status Applicable only to FEM module 00 - adaptive cut through 01 - reserved 10 - reserved 11 - store and forward bit 5: FEM back pressure status 0 - disabled; 1 - enabled bit 6-7 : reserved BYTE 27 : Expansion Port (EP) status2 bit 0-1 : LED status bit 0 : FEM link status 0 - no link; 1 - link bit 1 : FEM half/full duplex status 0 - full duplex; 1 - half duplex bit 2 : EP collision led status 0 - off; 1 - on bit 3-4 : bit 3 : tx LED status 0 - off; 1 - tx on bit 4 : rx LED status 0 - off; 1 - rx on bit 5-7 : reserved BYTE 28 : tenMb segment traffic/collision bit 0-1 : tenMb traffic LED status 00 - no traffic 01 - low traffic 10 - middle traffic 11 - high traffic bit 2-5 : tenMb collision LED status 0000 - none 0001 - 1 % 0010 - 3 % 0011 - 5 % 0100 - 10 % 0101 - >= 15 % bit 6-7 : reserved BYTE 29 : onehundredMb segment traffic/collision /Power/Switch LED status bit 0-1 : onehundredMb traffic LED status 00 - no traffic 01 - low traffic 10 - middle traffic 11 - high traffic bit 2-5 : onehundredMb collision LED status 0000 - none 0001 - 1 % 0010 - 3 % 0011 - 5 % 0100 - 10 % 0101 - >= 15 % bit 6 : Power LED 0 - OFF; 1 - ON bit 7 : Switch LED 0 - OFF; 1 - ON BYTE 30 :SNMP agent & switch status bit 0: internal switch bit 0 - not exist; 1 - exist bit 1: internal switch status 0 - inactive; 1 - active bit 2: expension switch bit 0 - bad; 1 - good bit 3: expension switch status 0 - inactive; 1 - active bit 4: agent bit 0 - not exist; 1 - exist bit 5 : master status 0 - Slave; 1 - Master bit 6 - 7 : reserved BYTE 31 : Rmon status bit 0 : rmon bit 0 - not exist; 1 - exist bit 1 - 2 :rmon segment 00 - all stack 01 - segment tenMb 10 - segment onehundredMb 11 - reserved bit 3 - 5 : RMON group Status 000 - not-present 001 - disabled 010 - Rmon-4Group 011 - Rmon-7Group 100 - Rmon-all 101 to 111 - reserved bit 6 -7 : reserved BYTE 32 : Hub Position(Hub ID)/Bus Termination bit 0 - 3 : hub position 0000 - invalid 0001 - 1 0010 - 2 0011 - 3 0100 - 4 0101 - 5 0110 - 6 0111 - 7 1000 - 8 1001 to 1111 - reserved bit 4 : termination status 0 - not end hub 1 - end hub in the stack bit 5 - 7 : reserved |
| IP stackInusedBootUpIP | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.6 | IpAddress | read-only | The Bootup IP address currently used by the Dual-Speed Hub system. The Bootup IP must reside in the same subnet as the stackIP. |
| IP stackInusedGateway | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.3 | IpAddress | read-only | The prefered gateway used to send traps. |
| IP stackInusedHostSlipAddr | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.5 | IpAddress | read-only | The Host SLIP address currently used by the Dual-Speed Hub system. |
| IP stackInusedIP | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.1 | IpAddress | read-only | The IP address currently used by the Dual-Speed Hub system. |
| IP stackInusedNetMask | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.2 | IpAddress | read-only | The subnet maskcurrently used by the Dual-Speed Hub system. |
| IP stackInusedServerSlipAddr | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.4 | IpAddress | read-only | The Server SLIP addresscurrently used by the Dual-Speed Hub system. |
| IP stackTemporalBootUpIP | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.12 | IpAddress | read-write | Used to change the Bootup IP address of the Dual-Speed Hub system. The Bootup IP must reside in the same subnet as the stackIP. |
| IP stackTemporalGateway | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.9 | IpAddress | read-write | Used to change the prefered gateway to send traps. |
| IP stackTemporalHostSlipAddr | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.11 | IpAddress | read-write | Used to change the Host SLIP address of the Dual-Speed Hub system. |
| IP stackTemporalIP | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.7 | IpAddress | read-write | Used to change the IP address of the Dual-Speed Hub system. |
| IP stackTemporalNetMask | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.8 | IpAddress | read-write | Used to change the subnet mask of the Dual-Speed Hub system. |
| IP stackTemporalServerSlipAddr | 1.3.6.1.4.1.207.8.1.20.3.11.1.1.1.10 | IpAddress | read-write | Used to change the Server SLIP address of the Dual-Speed Hub system. The SLIP address must reside in the same subnet as the stackIP. |
| CTR switchPortAlignmentErrors | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.6 | Counter | read-only | The number of valid-length frames received by the port that had alignment errors. |
| CTR switchPortBroadcastPackets | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.14 | Counter | read-only | The number of good broadcast frames received by the port. |
| CTR switchPortCollisions | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.10 | Counter | read-only | The number of collisions detected on the port. |
| CTR switchPortDataRateMismatches | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.13 | Counter | read-only | The number of times the incoming data rate mismatched the local clock source enough to cause a FIFO overflow or underflow. |
| CTR switchPortFCSErrors | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.5 | Counter | read-only | The number of valid-length frames received by the port that had FCS (frame check sequence) errors. |
| CTR switchPortFramesTooLong | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.7 | Counter | read-only | The number of frames received by the port that were longer than 1518 bytes. |
| CTR switchPortLateEvents | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.11 | Counter | read-only | The number of collisions detected on the port that occurred later than 512 bit-times into the transmission of a packet. |
| CTR switchPortMulticastPackets | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.15 | Counter | read-only | The number of good multicast (not broadcast) frames received by the port. |
| CTR switchPortReadableFrames | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.3 | Counter | read-only | The number of valid frames received by the port. |
| CTR switchPortReadableOctets | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.4 | Counter | read-only | The number of octets (bytes) in all valid frames received by the port. |
| CTR switchPortRunts | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.9 | Counter | read-only | The number of frames received by the port that were longer than 82 bits but shorter than 512 bits (64 bytes). |
| CTR switchPortShortEvents | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.8 | Counter | read-only | The number of frames received by the port that were shorter than 82 bits. |
| switchPortStatsEntry | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1 | not-accessible | ||
| INT switchPortStatsGroupID | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.1 | INTEGER | read-only | The group ID of the switch module port being referenced. If the group is not present, or if there is no switch module installed in the group, GetRequests and SetRequests are rejected with an error-status of noSuchName(2). GetNextRequests skip entries for nonexistent modules. |
| INT switchPortStatsID | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.2 | INTEGER | read-only | The port ID of the switch module port being referenced. Port 1 is always the internal 100Mbps port. Port 2 is always the internal 10Mbps port. Port 3 is always the external port. Note that port 2 is inactive on media modules and port 3 is inactive on internal switch modules. Note: Statistics for the external port are unavailable to the agent and are reported as 0. |
| switchPortStatsTable | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1 | not-accessible | This table provides statistics on each port on each switch module in the stack. Note that statistics for the external port on media and switch/media modules are unavailable to the agent and are reported as 0. Statistics for port 2 (the internal 10Mbps port) on media modules are also reported as 0. | |
| CTR switchPortVeryLongEvents | 1.3.6.1.4.1.207.8.1.20.3.11.1.3.1.1.1.12 | Counter | read-only | The number of times any activity continued for more than 4 to 7.5 milliseconds. |
RFC description
Manages configuration and monitoring of Allied Telesis FH800u dual-speed network hub stacks.
Start monitoring Allied Telesis Dual-Speed Hub (FH800u, legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.