| OID symbolic | OID numeric | Type | Access | Description |
| hpnicfTransceiver | 1.3.6.1.4.1.11.2.14.11.15.2.70 | | | The objects in this MIB module are used to display the
information of transceiver on interface. |
| hpnicfTransceiverInfoAdm | 1.3.6.1.4.1.11.2.14.11.15.2.70.1 | | | |
| hpnicfTransceiverInfoTable | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1 | | not-accessible | This table show the information of transceiver on interface. |
| hpnicfTransceiverInfoEntry | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1 | | not-accessible | The entry of the hpnicfTransceiverInfoTable. |
| OCT hpnicfTransceiverHardwareType | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.1 | OCTET STRING | read-only | Hardware type of the interface, such as SM(single mode). |
| OCT hpnicfTransceiverType | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.2 | OCTET STRING | read-only | Type of the interface, such as SFP/XFP/GBIC. |
| I32 hpnicfTransceiverWaveLength | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.3 | Integer32 | read-only | Wave length of the interface, measured in nanometer. |
| OCT hpnicfTransceiverVendorName | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.4 | OCTET STRING | read-only | Vendor name of the interface. |
| OCT hpnicfTransceiverSerialNumber | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.5 | OCTET STRING | read-only | Serial number of the interface. |
| INT hpnicfTransceiverFiberDiameterType | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.6 | INTEGER | read-only | The diameter of the fiber, measured in micron.
fiber9 - 9 micron multi-mode fiber
fiber50 - 50 micron multi-mode fiber
fiber625 - 62.5 micron multi-mode fiber
copper - copper cable. |
| I32 hpnicfTransceiverTransferDistance | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.7 | Integer32 | read-only | The maximal distance which the interface could transmit,
measured in meter. |
| T/F hpnicfTransceiverDiagnostic | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.8 | TruthValue | read-only | Indicating the digital diagnostic monitoring function . |
| I32 hpnicfTransceiverCurTXPower | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.9 | Integer32 | read-only | Indicating the current transmitted power .
The unit is in hundredths of dBM. |
| I32 hpnicfTransceiverMaxTXPower | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.10 | Integer32 | read-only | Indicating the maximal transmitted power .
The unit is in hundredths of dBM. |
| I32 hpnicfTransceiverMinTXPower | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.11 | Integer32 | read-only | Indicating the minimal transmitted power .
The unit is in hundredths of dBM. |
| I32 hpnicfTransceiverCurRXPower | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.12 | Integer32 | read-only | Indicating the current received power .
The unit is in hundredths of dBM. |
| I32 hpnicfTransceiverMaxRXPower | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.13 | Integer32 | read-only | Indicating the maximal received power .
The unit is in hundredths of dBM. |
| I32 hpnicfTransceiverMinRXPower | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.14 | Integer32 | read-only | Indicating the minimal received power .
The unit is in hundredths of dBM. |
| I32 hpnicfTransceiverTemperature | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.15 | Integer32 | read-only | Indicating the current temperature.
The unit is Celsius centigrade. |
| I32 hpnicfTransceiverVoltage | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.16 | Integer32 | read-only | Indicating the current voltage .
The unit is in hundredths of V |
| I32 hpnicfTransceiverBiasCurrent | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.17 | Integer32 | read-only | Indicating the current bias electric current .
The unit is in hundredths of mA |
| I32 hpnicfTransceiverTempHiAlarm | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.18 | Integer32 | read-only | Transceiver temperature high alarm threshold
limit in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius. |
| I32 hpnicfTransceiverTempLoAlarm | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.19 | Integer32 | read-only | Transceiver temperature low alarm threshold
limit in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius. |
| I32 hpnicfTransceiverTempHiWarn | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.20 | Integer32 | read-only | Transceiver temperature high warning threshold
limit in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius. |
| I32 hpnicfTransceiverTempLoWarn | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.21 | Integer32 | read-only | Transceiver temperature low warning threshold
limit in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius. |
| I32 hpnicfTransceiverVccHiAlarm | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.22 | Integer32 | read-only | Transceiver VCC high alarm threshold
limit in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver. |
| I32 hpnicfTransceiverVccLoAlarm | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.23 | Integer32 | read-only | Transceiver VCC low alarm threshold
limit in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver. |
| I32 hpnicfTransceiverVccHiWarn | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.24 | Integer32 | read-only | Transceiver VCC high warning threshold
limit in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver. |
| I32 hpnicfTransceiverVccLoWarn | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.25 | Integer32 | read-only | Transceiver VCC low warning threshold
limit in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver. |
| I32 hpnicfTransceiverBiasHiAlarm | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.26 | Integer32 | read-only | Transceiver bias high alarm threshold limit in microamps. |
| I32 hpnicfTransceiverBiasLoAlarm | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.27 | Integer32 | read-only | Transceiver bias low alarm threshold limit in microamps. |
| I32 hpnicfTransceiverBiasHiWarn | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.28 | Integer32 | read-only | Transceiver bias high warning threshold limit in microamps. |
| I32 hpnicfTransceiverBiasLoWarn | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.29 | Integer32 | read-only | Transceiver bias low warning threshold limit in microamps. |
| I32 hpnicfTransceiverPwrOutHiAlarm | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.30 | Integer32 | read-only | Transceiver transmit power high alarm
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| I32 hpnicfTransceiverPwrOutLoAlarm | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.31 | Integer32 | read-only | Transceiver transmit power low alarm
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| I32 hpnicfTransceiverPwrOutHiWarn | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.32 | Integer32 | read-only | Transceiver transmit power high warning
threshold limit in tenths of microwatts
As an example: 10000 is 1 milliwatt. |
| I32 hpnicfTransceiverPwrOutLoWarn | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.33 | Integer32 | read-only | Transceiver transmit power low warning
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| I32 hpnicfTransceiverRcvPwrHiAlarm | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.34 | Integer32 | read-only | Transceiver receive power high alarm
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| I32 hpnicfTransceiverRcvPwrLoAlarm | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.35 | Integer32 | read-only | Transceiver receive power low alarm
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| I32 hpnicfTransceiverRcvPwrHiWarn | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.36 | Integer32 | read-only | Transceiver receive power high warning
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| I32 hpnicfTransceiverRcvPwrLoWarn | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.37 | Integer32 | read-only | Transceiver receive power low warning
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt. |
| BIT hpnicfTransceiverErrors | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.38 | Bits | read-only | Bitmask indicating transceiver errors.
Transceiver information I/O error(0)
Transceiver information checksum error(1)
Transceiver type and port configuration mismatch(2)
Transceiver type not supported by port hardware(3)
WIS local fault(4)
Receive optical power fault(5)
PMA/PMD receiver local fault(6)
PCS receive local fault(7)
PHY XS receive local fault(8)
Laser bias current fault(9)
Laser temperature fault(10)
Laser output power fault(11)
TX fault(12)
PMA/PMD transmitter local fault(13)
PCS transmit local fault(14)
PHY XS Transmit Local Fault(15)
RX loss of signal(16)
Unused(17-31) |
| hpnicfTransceiverChannelTable | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2 | | not-accessible | This table provides statistics about transceiver with multi-channel. |
| hpnicfTransceiverChannelEntry | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1 | | not-accessible | The entry of the hpnicfTransceiverChannelTable. |
| I32 hpnicfTransceiverChannelIndex | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.1 | Integer32 | not-accessible | The channel index of transceiver.
Indicating one channel of the interface. |
| I32 hpnicfTransceiverChannelCurTXPower | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.2 | Integer32 | read-only | Indicating the current transmission power.
The unit is in hundredths of dBM. |
| I32 hpnicfTransceiverChannelCurRXPower | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.3 | Integer32 | read-only | Indicating the current received power.
The unit is in hundredths of dBM. |
| I32 hpnicfTransceiverChannelTemperature | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.4 | Integer32 | read-only | Indicating the current temperature.
The unit is Celsius centigrade. |
| I32 hpnicfTransceiverChannelBiasCurrent | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.5 | Integer32 | read-only | Indicating the current bias electric current.
The unit is in hundredths of mA. |