All MIBs › CPQCMC-MIB
Category: Hardware and Environment, Vendor: HP/HPE
Description: Manages Compaq/HP Consolidated Management Console (CMC) blade server chassis and module objects.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CPQCMC-MIB?
CPQCMC-MIB is a legacy Compaq (later HP, enterprise OID 232, built on CPQHOST-MIB) proprietary MIB for the Compaq Cluster/Console Management Card (CMC), reporting environmental and relay status. Its objects cover MIB revision/condition, OS common poll frequency, device condition, language/temperature-unit/audible-alarm settings, a password and password-option, relay quit/logic controls (two relays), and per-temperature-probe availability with relay and audible-alarm warning/max/min thresholds (for two probes shown, extensible). As a hardware-status MIB it lets an administrator confirm temperature-threshold configuration and relay behavior on a Compaq CMC-managed environment. It is deployed on legacy Compaq (HP) systems with a Cluster/Console Management Card. Engineers can download the CPQCMC-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in CPQCMC-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Legacy Compaq (HP) systems (Cluster/Console Management Card)
Monitoring Examples
An administrator checks cpqCmcSetupTemp1RelaysMax to confirm the temperature threshold that triggers a relay action is set appropriately on a Compaq CMC-managed system.
What Can Be Monitored
- temperature thresholds and relay configuration
This MIB depends on
Related MIBs
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| cpqCmc | 1.3.6.1.4.1.232.153 | |||
| NTF cpqCmcalarm1 | 1.3.6.1.4.1.232.153.0.153017 | Alarm 1, set from Network management | ||
| NTF cpqCmcalarm2 | 1.3.6.1.4.1.232.153.0.153018 | Alarm 2, set from Network management | ||
| NTF cpqCmcalarmAux1 | 1.3.6.1.4.1.232.153.0.153015 | The rack auxiliary alarm input #1 has been triggered. | ||
| NTF cpqCmcalarmAux2 | 1.3.6.1.4.1.232.153.0.153016 | The rack auxiliary alarm input #2 has been triggered. | ||
| NTF cpqCmcalarmFan1 | 1.3.6.1.4.1.232.153.0.153003 | The status of Fan 1 has changed. Action: Refer to Trap Details for more information. | ||
| NTF cpqCmcalarmFan2 | 1.3.6.1.4.1.232.153.0.153004 | The status of Fan 2 has changed. Action: Refer to Trap Details for more information. | ||
| NTF cpqCmcalarmHumidity | 1.3.6.1.4.1.232.153.0.153006 | The humidity of the rack is outside the specified threshold. Action: Check the air handling system for the rack and refer to Trap Details for more information. | ||
| NTF cpqCmcalarmInput1 | 1.3.6.1.4.1.232.153.0.153007 | The door or sidepanel of the rack has been opened (access point #1). Action: Check for unauthorized intrusion and refer to Trap Details for more information. | ||
| NTF cpqCmcalarmInput2 | 1.3.6.1.4.1.232.153.0.153008 | The door or sidepanel of the rack has been opened (access point #2). Action: Check for unauthorized intrusion and refer to Trap Details for more information. | ||
| NTF cpqCmcalarmInput3 | 1.3.6.1.4.1.232.153.0.153009 | The door or sidepanel of the rack has been opened (access point #3). Action: Check for unauthorized intrusion and refer to Trap Details for more information. | ||
| NTF cpqCmcalarmInput4 | 1.3.6.1.4.1.232.153.0.153010 | The door or sidepanel of the rack has been opened (access point #4). Action: Check for unauthorized intrusion and refer to Trap Details for more information. | ||
| NTF cpqCmcalarmLock1 | 1.3.6.1.4.1.232.153.0.153011 | Rack door lock #1 alarm. Action: Ensure the door is completely closed and check for unauthorized intrusion and refer to Trap Details for more information. | ||
| NTF cpqCmcalarmLock1Dev | 1.3.6.1.4.1.232.153.0.153019 | The rack door locking device #1 has failed. Action: Check the device lock cable or failed battery and refer to Trap Details for more information. | ||
| NTF cpqCmcalarmLock2 | 1.3.6.1.4.1.232.153.0.153012 | Rack door lock #2 alarm. Action: Ensure the door is completely closed and check for unauthorized intrusion and refer to Trap Details for more information. | ||
| NTF cpqCmcalarmLock2Dev | 1.3.6.1.4.1.232.153.0.153020 | The rack door locking device #2 has failed. Action: Check the device lock cable or failed battery and refer to Trap Details for more information. | ||
| NTF cpqCmcalarmShock | 1.3.6.1.4.1.232.153.0.153014 | The rack shock detector has detected a vibration to the rack. Action: Investigate rack. | ||
| NTF cpqCmcalarmSmoke | 1.3.6.1.4.1.232.153.0.153013 | The rack smoke detector has detected smoke. Action: Investigate rack for an over temperature condition and refer to Trap Details for more information. | ||
| NTF cpqCmcalarmTemp1 | 1.3.6.1.4.1.232.153.0.153001 | The temperature at rack sensor 1 is outside the specified threshold. Action: Check the air handling system for the rack and refer to Trap Details for more information. | ||
| NTF cpqCmcalarmTemp2 | 1.3.6.1.4.1.232.153.0.153002 | The temperature at rack sensor 2 is outside the specified threshold. Action: Check the air handling system for the rack and refer to Trap Details for more information. | ||
| NTF cpqCmcalarmVoltage | 1.3.6.1.4.1.232.153.0.153005 | The AC voltage of the rack is outside the specified threshold. Action: Check the incoming power source and ensure all cables are inserted correctly. | ||
| cpqCmcComponent | 1.3.6.1.4.1.232.153.2 | |||
| cpqCmcControl | 1.3.6.1.4.1.232.153.2.2.5 | |||
| cpqCmcDevice | 1.3.6.1.4.1.232.153.2.2 | |||
| INT cpqCmcDeviceCondition | 1.3.6.1.4.1.232.153.2.2.1 | INTEGER | read-only | Condition of CMC device, (3) an overload of the 24V DC supply to the connected accessories occurred (4) the overload-protection (fuse) has released |
| cpqCmcInterface | 1.3.6.1.4.1.232.153.2.1 | |||
| cpqCmcLog | 1.3.6.1.4.1.232.153.2.2.6 | |||
| STR cpqCmcLogClass | 1.3.6.1.4.1.232.153.2.2.6.2.1.5 | DisplayString | read-only | Status of log information. |
| STR cpqCmcLogDate | 1.3.6.1.4.1.232.153.2.2.6.2.1.2 | DisplayString | read-only | Date of log information. |
| cpqCmcLogEntry | 1.3.6.1.4.1.232.153.2.2.6.2.1 | not-accessible | Log-table entries | |
| INT cpqCmclogicRelay1 | 1.3.6.1.4.1.232.153.2.2.2.1.1.8 | INTEGER | read-write | Logic of Relay 1: (2) Relay will pick up in case of an alarm (3) Relay will release in case of an alarm (4) not used |
| INT cpqCmclogicRelay2 | 1.3.6.1.4.1.232.153.2.2.2.1.1.9 | INTEGER | read-write | Logic of Relay 2: (2) Relay will pick up in case of an alarm (3) Relay will release in case of an alarm (4) not used |
| INT cpqCmcLogIndex | 1.3.6.1.4.1.232.153.2.2.6.2.1.1 | INTEGER | read-only | Index for the Log-table. Its value ranges between 1 and the value of cpqCmcLogsNumber |
| INT cpqCmcLogsNumber | 1.3.6.1.4.1.232.153.2.2.6.1 | INTEGER | read-only | Number of Log-entries |
| cpqCmcLogTable | 1.3.6.1.4.1.232.153.2.2.6.2 | not-accessible | Log-table | |
| STR cpqCmcLogText | 1.3.6.1.4.1.232.153.2.2.6.2.1.4 | DisplayString | read-only | Log information. |
| STR cpqCmcLogTime | 1.3.6.1.4.1.232.153.2.2.6.2.1.3 | DisplayString | read-only | Time of log information. |
| INT cpqCmcMibCondition | 1.3.6.1.4.1.232.153.1.3 | INTEGER | read-only | The overall condition (status) of the system (rack(s)) represented by this MIB. (2) OK (3) a minor problem, warning condition (yellow LED on CMC) (4) a major problem (red LED on CMC) |
| cpqCmcMibRev | 1.3.6.1.4.1.232.153.1 | |||
| INT cpqCmcMibRevMajor | 1.3.6.1.4.1.232.153.1.1 | INTEGER | read-only | The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information, correct interpretation of data may require a MIB document with the same major revision level. |
| INT cpqCmcMibRevMinor | 1.3.6.1.4.1.232.153.1.2 | INTEGER | read-only | The Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred. |
| cpqCmcOsCommon | 1.3.6.1.4.1.232.153.2.1.1 | |||
| INT cpqCmcOsCommonPollFreq | 1.3.6.1.4.1.232.153.2.1.1.1 | INTEGER | read-write | The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management station, it does not poll the device driver at a specific interval. |
| STR cpqCmcPassword | 1.3.6.1.4.1.232.153.2.2.2.1.1.4 | DisplayString | read-write | Password to get access to terminal or LCD |
| INT cpqCmcPasswordOption | 1.3.6.1.4.1.232.153.2.2.2.1.1.5 | INTEGER | read-write | Enable or disable password entry to get access to terminal or LCD |
| INT cpqCmcquitRelay1 | 1.3.6.1.4.1.232.153.2.2.2.1.1.6 | INTEGER | read-write | Enable or disable acknowledging currently active alarm relay 1 (with 'ENTER' on CMC). |
| INT cpqCmcquitRelay2 | 1.3.6.1.4.1.232.153.2.2.2.1.1.7 | INTEGER | read-write | Enable or disable acknowledging currently active alarm relay 2 (with 'ENTER' on CMC). |
| INT cpqCmcSetAlarm1 | 1.3.6.1.4.1.232.153.2.2.5.7 | INTEGER | read-write | Is used to set an alarm in the CMC from the management-station. With this command the management-station can i.e. switch on an alarm-relay or the AudibleAlarm of the CMC. Can be used for alert-handling |
| INT cpqCmcSetAlarm2 | 1.3.6.1.4.1.232.153.2.2.5.8 | INTEGER | read-write | Is used to set an alarm in the CMC from the management-station. With this command the management-station can i.e. switch on an alarm-relay or the AudibleAlarm of the CMC. Can be used for alert-handling |
| INT cpqCmcsetAudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.1.3 | INTEGER | read-write | Audible alarm in CMC unit: (2): silencing with button on CMC is enabled (3): silencing with button on CMC is disabled (4): audible alarm is off (general). On/off of audible alarm for each event is possible in cpqCmcsetupEvents-group |
| INT cpqCmcSetFan1 | 1.3.6.1.4.1.232.153.2.2.5.9 | INTEGER | read-write | Is used for run and stop control of fan1. (2) fan will run and stop according to temperature of sensor 1 and threshold of fan1 (3) fan will run independent of temperature and threshold (4) fan will stop independent of temperature and threshold (3) and (4) can be used for alert handling. |
| INT cpqCmcSetFan2 | 1.3.6.1.4.1.232.153.2.2.5.10 | INTEGER | read-write | Is used for run and stop control of fan2. (2) fan will run and stop according to temperature of sensor 2 and threshold of fan2 (3) fan will run independent of temperature and threshold (4) fan will stop independent of temperature and threshold (3) and (4) can be used for alert handling |
| INT cpqCmcsetLanguage | 1.3.6.1.4.1.232.153.2.2.2.1.1.1 | INTEGER | read-write | Language of LCD |
| INT cpqCmcSetLock1Key | 1.3.6.1.4.1.232.153.2.2.5.3 | INTEGER | read-write | Enable or disable unlocking of the rack-door with external components like keypad or remote input. With this command the management station can set the conditions for unlocking the door: (2) unlocking is disabled, no unlocking with keypad or remote input (3) unlocking with keypad or remote signal (both) is enabled (4) unlocking with keypad (only) is enabled (5) unlocking with remote input (only) is enabled Unlocking door with the cpqCmcSetLock1Lock-command does not depend on this variable |
| INT cpqCmcSetLock1Lock | 1.3.6.1.4.1.232.153.2.2.5.2 | INTEGER | read-write | Set door locking device 1, see table With this command the management-station can set the conditions for the door locking device (2) Door will be locked (3) Door will be unlocked for a defined time, time can be changed, see cpqCmcSetupLock1Time (4) Door is generally unlocked Locking and unlocking with this command can not be enabled or disabled with cpqCmcSetLock1Key-command |
| INT cpqCmcSetLock2Key | 1.3.6.1.4.1.232.153.2.2.5.5 | INTEGER | read-write | Enable or disable unlocking of the rack-door with external components like keypad or remote input. With this command the management-station can set the conditions for unlocking the door: (2) unlocking is disabled, no unlocking with keypad or remote input (3) unlocking with keypad or remote signal (both) is enabled (4) unlocking with keypad (only) is enabled (5) unlocking with remote input (only) is enabled Unlocking door with the cpqCmcSetDoor2-command does not depend on this variable |
| INT cpqCmcSetLock2Lock | 1.3.6.1.4.1.232.153.2.2.5.4 | INTEGER | read-write | Set door locking device 2, see table With this command the management-station can set the conditions for the door locking device (2) Door will be locked (3) Door will be unlocked for a defined time, time can be changed, see cpqCmcSetupLock2Time (4) Door is generally unlocked Locking and unlocking with this command can not be enabled or disabled with cpqCmcSetLock2Key-command |
| STR cpqCmcSetMessage | 1.3.6.1.4.1.232.153.2.2.5.6 | DisplayString | read-write | Set message to CMC, for future use |
| INT cpqCmcSetQuitRelay1 | 1.3.6.1.4.1.232.153.2.2.5.11 | INTEGER | read-write | Status and quit of alarm relay 1. (2) relay is switched because of an alarm (3) relay is not switched, no alarm (4) (set) will quit relay 1 in case of alarm |
| INT cpqCmcSetQuitRelay2 | 1.3.6.1.4.1.232.153.2.2.5.12 | INTEGER | read-write | Status and quit of alarm relay 2. (2) relay is switched because of an alarm (3) relay is not switched, no alarm (4) (set) will quit relay 2 in case of alarm |
| INT cpqCmcsetTempUnit | 1.3.6.1.4.1.232.153.2.2.2.1.1.2 | INTEGER | read-write | Unit of all temperature values and thresholds, Celsius or Fahrenheit |
| cpqCmcSetup | 1.3.6.1.4.1.232.153.2.2.2 | |||
| cpqCmcSetupAlarm1 | 1.3.6.1.4.1.232.153.2.2.2.1.2.17 | |||
| INT cpqCmcSetupAlarm1AudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.17.2 | INTEGER | read-write | Alert handling of Audible Alarm of in case of an alarm condition of Alarm 1: (2) Start Audible Alarm (3) No Audible Alarm |
| STR cpqCmcSetupAlarm1Description | 1.3.6.1.4.1.232.153.2.2.2.1.2.17.3 | DisplayString | read-write | Descriptional text of alarm 1 |
| INT cpqCmcSetupAlarm1Relays | 1.3.6.1.4.1.232.153.2.2.2.1.2.17.1 | INTEGER | read-write | Alert handling of Alarm Relays in case of an alarm condition of Alarm 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| cpqCmcSetupAlarm2 | 1.3.6.1.4.1.232.153.2.2.2.1.2.18 | |||
| INT cpqCmcSetupAlarm2AudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.18.2 | INTEGER | read-write | Alert handling of Audible Alarm of in case of an alarm condition of Alarm 2: (2) Start Audible Alarm (3) No Audible Alarm |
| STR cpqCmcSetupAlarm2Description | 1.3.6.1.4.1.232.153.2.2.2.1.2.18.3 | DisplayString | read-write | Descriptional text of alarm 2 |
| INT cpqCmcSetupAlarm2Relays | 1.3.6.1.4.1.232.153.2.2.2.1.2.18.1 | INTEGER | read-write | Alert handling of Alarm Relays in case of an alarm condition of Alarm 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| cpqCmcSetupAux1 | 1.3.6.1.4.1.232.153.2.2.2.1.2.15 | |||
| INT cpqCmcSetupAux1AudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.15.3 | INTEGER | read-write | Alert handling of Audible Alarm of in case of an alarm condition of Aux 1: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupAux1Avail | 1.3.6.1.4.1.232.153.2.2.2.1.2.15.1 | INTEGER | read-write | Aux 1 sensor: (2) available (3) not available |
| STR cpqCmcSetupAux1Description | 1.3.6.1.4.1.232.153.2.2.2.1.2.15.5 | DisplayString | read-write | Descriptional text of the digital input (Aux1) |
| INT cpqCmcSetupAux1InputType | 1.3.6.1.4.1.232.153.2.2.2.1.2.15.4 | INTEGER | read-write | Type of other digital input (used for any digital signal): (2) contact is normally open, no alarm if contact is open, alarm if contact is closed (3) contact is normally closed, no alarm if contact is closed, alarm if contact is open |
| INT cpqCmcSetupAux1Relays | 1.3.6.1.4.1.232.153.2.2.2.1.2.15.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of an alarm condition of Aux 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupAux1Unlock | 1.3.6.1.4.1.232.153.2.2.2.1.2.15.6 | INTEGER | read-write | Lock will be unlocked with Aux-Input 1: (2) no lock will be unlocked (3) only lock1 will be unlocked (4) only lock2 will be unlocked (5) both locks will be unlocked |
| cpqCmcSetupAux2 | 1.3.6.1.4.1.232.153.2.2.2.1.2.16 | |||
| INT cpqCmcSetupAux2AudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.16.3 | INTEGER | read-write | Alert handling of Audible Alarm of in case of an alarm condition of Aux 2: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupAux2Avail | 1.3.6.1.4.1.232.153.2.2.2.1.2.16.1 | INTEGER | read-write | Aux 2 sensor: (2) available (3) not available |
| STR cpqCmcSetupAux2Description | 1.3.6.1.4.1.232.153.2.2.2.1.2.16.5 | DisplayString | read-write | Descriptional text of the digital input (Aux2) |
| INT cpqCmcSetupAux2InputType | 1.3.6.1.4.1.232.153.2.2.2.1.2.16.4 | INTEGER | read-write | Type of other digital input (used for any digital signal): (2) contact is normally open, no alarm if contact is open, alarm if contact is closed (3) contact is normally closed, no alarm if contact is closed, alarm if contact is open |
| INT cpqCmcSetupAux2Relays | 1.3.6.1.4.1.232.153.2.2.2.1.2.16.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of an alarm condition of Aux 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupAux2Unlock | 1.3.6.1.4.1.232.153.2.2.2.1.2.16.6 | INTEGER | read-write | Lock will be unlocked with Aux-Input 2: (2) no lock will be unlocked (3) only lock1 will be unlocked (4) only lock2 will be unlocked (5) both locks will be unlocked |
| NTF cpqCmcSetupChanged | 1.3.6.1.4.1.232.153.0.153100 | Setup of CMC has changed. | ||
| cpqCmcSetupClock | 1.3.6.1.4.1.232.153.2.2.2.1.3 | |||
| cpqCmcSetupConfig | 1.3.6.1.4.1.232.153.2.2.2.1 | |||
| STR cpqCmcSetupDate | 1.3.6.1.4.1.232.153.2.2.2.1.3.1 | DisplayString | read-write | actual Date in format DD.MM.YYYY |
| cpqCmcSetupEvents | 1.3.6.1.4.1.232.153.2.2.2.1.2 | |||
| cpqCmcSetupFan1 | 1.3.6.1.4.1.232.153.2.2.2.1.2.3 | |||
| INT cpqCmcSetupFan1AudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.3.3 | INTEGER | read-write | Alert handling of Audible Alarm of in case of alarm condition of Fan 1: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupFan1Avail | 1.3.6.1.4.1.232.153.2.2.2.1.2.3.1 | INTEGER | read-write | Fan 1: (2) Fan 1 available (3) Fan 1 not available |
| INT cpqCmcSetupFan1Relays | 1.3.6.1.4.1.232.153.2.2.2.1.2.3.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of alarm condition of Fan 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| cpqCmcSetupFan2 | 1.3.6.1.4.1.232.153.2.2.2.1.2.4 | |||
| INT cpqCmcSetupFan2AudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.4.3 | INTEGER | read-write | Alert handling of Audible Alarm of in case of alarm condition of Fan 2: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupFan2Avail | 1.3.6.1.4.1.232.153.2.2.2.1.2.4.1 | INTEGER | read-write | Fan 2: (2) Fan 2 available (3) Fan 2 not available |
| INT cpqCmcSetupFan2Relays | 1.3.6.1.4.1.232.153.2.2.2.1.2.4.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of alarm condition of Fan 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| cpqCmcSetupGeneral | 1.3.6.1.4.1.232.153.2.2.2.1.1 | |||
| cpqCmcSetupHumidity | 1.3.6.1.4.1.232.153.2.2.2.1.2.6 | |||
| INT cpqCmcSetupHumidityAudibleAlarmMax | 1.3.6.1.4.1.232.153.2.2.2.1.2.6.4 | INTEGER | read-write | Alert handling of Audible Alarm of in case of max. alarm condition of humidity monitoring: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupHumidityAudibleAlarmMin | 1.3.6.1.4.1.232.153.2.2.2.1.2.6.5 | INTEGER | read-write | Alert handling of Audible Alarm of in case of min. alarm condition of humidity monitoring: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupHumidityAvail | 1.3.6.1.4.1.232.153.2.2.2.1.2.6.1 | INTEGER | read-write | Humidity sensor: (2) available (3) not available |
| INT cpqCmcSetupHumidityRelaysMax | 1.3.6.1.4.1.232.153.2.2.2.1.2.6.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of max. alarm condition of humidity monitoring: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupHumidityRelaysMin | 1.3.6.1.4.1.232.153.2.2.2.1.2.6.3 | INTEGER | read-write | Alert handling of Alarm Relays in case of min. alarm condition of humidity monitoring: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| cpqCmcSetupInput1 | 1.3.6.1.4.1.232.153.2.2.2.1.2.7 | |||
| INT cpqCmcSetupInput1AudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.7.3 | INTEGER | read-write | Alert handling of Audible Alarm of in case of a warning condition of Input 1 (Door/Sidewall open): (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupInput1Avail | 1.3.6.1.4.1.232.153.2.2.2.1.2.7.1 | INTEGER | read-write | Input 1 sensor: (2) available (3) not available |
| STR cpqCmcSetupInput1Description | 1.3.6.1.4.1.232.153.2.2.2.1.2.7.6 | DisplayString | read-write | Descriptional text of Input1 |
| INT cpqCmcSetupInput1FansOff | 1.3.6.1.4.1.232.153.2.2.2.1.2.7.4 | INTEGER | read-write | Fan switching off if Door/Sidewall 1 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off |
| INT cpqCmcSetupInput1Lock | 1.3.6.1.4.1.232.153.2.2.2.1.2.7.7 | INTEGER | read-write | Door/Sidewall 1 is locked by: (2) no locking device (3) locking device 1 (4) locking device 2 (5) both locking devices |
| INT cpqCmcSetupInput1Relays | 1.3.6.1.4.1.232.153.2.2.2.1.2.7.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of a warning condition of Input 1 (Door/Sidewall open): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupInput1ShockSensor | 1.3.6.1.4.1.232.153.2.2.2.1.2.7.5 | INTEGER | read-write | Shock sensor function if Door/Sidewall 1 is opened: (2) Shock Sensor is off (disabled) (3) Shock Sensor is on (enabled) |
| cpqCmcSetupInput2 | 1.3.6.1.4.1.232.153.2.2.2.1.2.8 | |||
| INT cpqCmcSetupInput2AudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.8.3 | INTEGER | read-write | Alert handling of Audible Alarm of in case of a warning condition of Input 2 (Door/Sidewall open): (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupInput2Avail | 1.3.6.1.4.1.232.153.2.2.2.1.2.8.1 | INTEGER | read-write | Input 2 sensor: (2) available (3) not available |
| STR cpqCmcSetupInput2Description | 1.3.6.1.4.1.232.153.2.2.2.1.2.8.6 | DisplayString | read-write | Descriptional text of Input2 |
| INT cpqCmcSetupInput2FansOff | 1.3.6.1.4.1.232.153.2.2.2.1.2.8.4 | INTEGER | read-write | Fan switching off if Door/Sidewall 2 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off |
| INT cpqCmcSetupInput2Lock | 1.3.6.1.4.1.232.153.2.2.2.1.2.8.7 | INTEGER | read-write | Door/Sidewall 2 is locked by: (2) no locking device (3) locking device 1 (4) locking device 2 (5) both locking devices |
| INT cpqCmcSetupInput2Relays | 1.3.6.1.4.1.232.153.2.2.2.1.2.8.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of a warning condition of Input 2 (Door/Sidewall open): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupInput2ShockSensor | 1.3.6.1.4.1.232.153.2.2.2.1.2.8.5 | INTEGER | read-write | Shock sensor function if Door/Sidewall 2 is opened: (2) Shock Sensor is off (disabled) (3) Shock Sensor is on (enabled) |
| cpqCmcSetupInput3 | 1.3.6.1.4.1.232.153.2.2.2.1.2.9 | |||
| INT cpqCmcSetupInput3AudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.9.3 | INTEGER | read-write | Alert handling of Audible Alarm of in case of a warning condition of Input 3 (Door/Sidewall open): (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupInput3Avail | 1.3.6.1.4.1.232.153.2.2.2.1.2.9.1 | INTEGER | read-write | Input 3 sensor: (2) available (3) not available |
| STR cpqCmcSetupInput3Description | 1.3.6.1.4.1.232.153.2.2.2.1.2.9.6 | DisplayString | read-write | Descriptional text of Input3 |
| INT cpqCmcSetupInput3FansOff | 1.3.6.1.4.1.232.153.2.2.2.1.2.9.4 | INTEGER | read-write | Fan switching off if Door/Sidewall 3 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off |
| INT cpqCmcSetupInput3Lock | 1.3.6.1.4.1.232.153.2.2.2.1.2.9.7 | INTEGER | read-write | Door/Sidewall 3 is locked by: (2) no locking device (3) locking device 1 (4) locking device 2 (5) both locking devices |
| INT cpqCmcSetupInput3Relays | 1.3.6.1.4.1.232.153.2.2.2.1.2.9.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of a warning condition of Input 3 (Door/Sidewall open): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupInput3ShockSensor | 1.3.6.1.4.1.232.153.2.2.2.1.2.9.5 | INTEGER | read-write | Shock sensor function if Door/Sidewall 3 is opened: (2) Shock Sensor is off (disabled) (3) Shock Sensor is on (enabled) |
| cpqCmcSetupInput4 | 1.3.6.1.4.1.232.153.2.2.2.1.2.10 | |||
| INT cpqCmcSetupInput4AudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.10.3 | INTEGER | read-write | Alert handling of Audible Alarm of in case of a warning condition of Input 4 (Door/Sidewall open): (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupInput4Avail | 1.3.6.1.4.1.232.153.2.2.2.1.2.10.1 | INTEGER | read-write | Input 4 sensor: (2) available (3) not available |
| STR cpqCmcSetupInput4Description | 1.3.6.1.4.1.232.153.2.2.2.1.2.10.6 | DisplayString | read-write | Descriptional text of Input4 |
| INT cpqCmcSetupInput4FansOff | 1.3.6.1.4.1.232.153.2.2.2.1.2.10.4 | INTEGER | read-write | Fan switching off if Door/Sidewall 4 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off |
| INT cpqCmcSetupInput4Lock | 1.3.6.1.4.1.232.153.2.2.2.1.2.10.7 | INTEGER | read-write | Door/Sidewall 4 is locked by: (2) no locking device (3) locking device 1 (4) locking device 2 (5) both locking devices |
| INT cpqCmcSetupInput4Relays | 1.3.6.1.4.1.232.153.2.2.2.1.2.10.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of a warning condition of Input 4 (Door/Sidewall open): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupInput4ShockSensor | 1.3.6.1.4.1.232.153.2.2.2.1.2.10.5 | INTEGER | read-write | Shock sensor function if Door/Sidewall 4 is opened: (2) Shock Sensor is off (disabled) (3) Shock Sensor is on (enabled) |
| cpqCmcSetupLock1 | 1.3.6.1.4.1.232.153.2.2.2.1.2.11 | |||
| INT cpqCmcSetupLock1AudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.11.4 | INTEGER | read-write | Alert handling of Audible Alarm of in case of an alarm condition of Lock 1: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupLock1AudibleAlarmDevice | 1.3.6.1.4.1.232.153.2.2.2.1.2.11.5 | INTEGER | read-write | Alert handling of Audible Alarm of in case of an alarm condition of Locking device 1 (power fail, low battery..): (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupLock1Avail | 1.3.6.1.4.1.232.153.2.2.2.1.2.11.1 | INTEGER | read-write | Door locking device 1: (2) device available (3) device not available, no alarm, if door is not locked |
| INT cpqCmcSetupLock1BattLowUnlock | 1.3.6.1.4.1.232.153.2.2.2.1.2.11.8 | INTEGER | read-write | Unlock door in case of low battery of locking device: (2) disabled (3) auto unlock the door (4) unlock door with remote signal |
| INT cpqCmcSetupLock1LifeFailUnlock | 1.3.6.1.4.1.232.153.2.2.2.1.2.11.10 | INTEGER | read-write | Unlock door in case of lifecheck failure (connection CMClocking device): (2) disabled (3) auto unlock the door (4) unlock door with remote signal |
| INT cpqCmcSetupLock1NetFailUnlock | 1.3.6.1.4.1.232.153.2.2.2.1.2.11.9 | INTEGER | read-write | Unlock door in case of network failure: (2) disabled (3) auto unlock the door (4) unlock door with remote signal |
| INT cpqCmcSetupLock1PwrFailUnlock | 1.3.6.1.4.1.232.153.2.2.2.1.2.11.7 | INTEGER | read-write | Unlock door in case of power fail of locking device: (2) disabled (3) auto unlock the door (4) unlock door with remote signal |
| INT cpqCmcSetupLock1Relays | 1.3.6.1.4.1.232.153.2.2.2.1.2.11.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of an alarm condition of Lock 1 (door not locked..): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupLock1RelaysDevice | 1.3.6.1.4.1.232.153.2.2.2.1.2.11.3 | INTEGER | read-write | Alert handling of Alarm Relays in case of an alarm condition of Locking device 1 (power fail, low battery...): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupLock1Time | 1.3.6.1.4.1.232.153.2.2.2.1.2.11.6 | INTEGER | read-write | Time in seconds while the lock 1 is unlocked after getting an unlock-command |
| cpqCmcSetupLock2 | 1.3.6.1.4.1.232.153.2.2.2.1.2.12 | |||
| INT cpqCmcSetupLock2AudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.12.4 | INTEGER | read-write | Alert handling of Audible Alarm of in case of an alarm condition of Lock 2: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupLock2AudibleAlarmDevice | 1.3.6.1.4.1.232.153.2.2.2.1.2.12.5 | INTEGER | read-write | Alert handling of Audible Alarm of in case of an alarm condition of Locking device 2 (power fail, low battery..): (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupLock2Avail | 1.3.6.1.4.1.232.153.2.2.2.1.2.12.1 | INTEGER | read-write | Door locking device 2: (2) device available (3) device not available, no alarm, if door is not locked |
| INT cpqCmcSetupLock2BattLowUnlock | 1.3.6.1.4.1.232.153.2.2.2.1.2.12.8 | INTEGER | read-write | Unlock door in case of low battery of locking device: (2) disabled (3) auto unlock the door (4) unlock door with remote signal |
| INT cpqCmcSetupLock2LifeFailUnlock | 1.3.6.1.4.1.232.153.2.2.2.1.2.12.10 | INTEGER | read-write | Unlock door in case of lifecheck failure (connection CMClocking device): (2) disabled (3) auto unlock the door (4) unlock door with remote signal |
| INT cpqCmcSetupLock2NetFailUnlock | 1.3.6.1.4.1.232.153.2.2.2.1.2.12.9 | INTEGER | read-write | Unlock door in case of network failure: (2) disabled (3) auto unlock the door (4) unlock door with remote signal |
| INT cpqCmcSetupLock2PwrFailUnlock | 1.3.6.1.4.1.232.153.2.2.2.1.2.12.7 | INTEGER | read-write | Unlock door in case of power fail of locking device: (2) disabled (3) auto unlock the door (4) unlock door with remote signal |
| INT cpqCmcSetupLock2Relays | 1.3.6.1.4.1.232.153.2.2.2.1.2.12.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of an alarm condition of Lock 2 (door not locked..): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupLock2RelaysDevice | 1.3.6.1.4.1.232.153.2.2.2.1.2.12.3 | INTEGER | read-write | Alert handling of Alarm Relays in case of an alarm condition of Locking device 2 (power fail, low battery...): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupLock2Time | 1.3.6.1.4.1.232.153.2.2.2.1.2.12.6 | INTEGER | read-write | Time in seconds while the lock 2 is unlocked after getting an unlock-command |
| cpqCmcSetupShock | 1.3.6.1.4.1.232.153.2.2.2.1.2.14 | |||
| INT cpqCmcSetupShockAudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.14.3 | INTEGER | read-write | Alert handling of Audible Alarm of in case of an alarm condition of Shock Sensor: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupShockAvail | 1.3.6.1.4.1.232.153.2.2.2.1.2.14.1 | INTEGER | read-write | Shock sensor: (2) available (3) not available |
| INT cpqCmcSetupShockRelays | 1.3.6.1.4.1.232.153.2.2.2.1.2.14.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of an alarm condition of Shock Sensor: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupShockSensitivity | 1.3.6.1.4.1.232.153.2.2.2.1.2.14.4 | INTEGER | read-write | Sensitivity of shock-sensor. 1 = low sensitivity, 10 = high sensitivity |
| cpqCmcSetupSmoke | 1.3.6.1.4.1.232.153.2.2.2.1.2.13 | |||
| INT cpqCmcSetupSmokeAudibleAlarm | 1.3.6.1.4.1.232.153.2.2.2.1.2.13.3 | INTEGER | read-write | Alert handling of Audible Alarm of in case of an alarm condition of Smoke Sensor: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupSmokeAvail | 1.3.6.1.4.1.232.153.2.2.2.1.2.13.1 | INTEGER | read-write | Smoke sensor: (2) available (3) not available |
| INT cpqCmcSetupSmokeFansOff | 1.3.6.1.4.1.232.153.2.2.2.1.2.13.4 | INTEGER | read-write | Fan switching off if in case of smoke-alarm: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off |
| INT cpqCmcSetupSmokeRelays | 1.3.6.1.4.1.232.153.2.2.2.1.2.13.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of an alarm condition of Smoke Sensor: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupSmokeUnlock | 1.3.6.1.4.1.232.153.2.2.2.1.2.13.5 | INTEGER | read-write | Lock is unlocked in case of smoke-alarm: (2) both locks will be unlocked (3) only lock1 will be unlocked (4) only lock2 will be unlocked (5) no lock will be unlocked |
| cpqCmcSetupTemp1 | 1.3.6.1.4.1.232.153.2.2.2.1.2.1 | |||
| INT cpqCmcSetupTemp1AudibleAlarmMax | 1.3.6.1.4.1.232.153.2.2.2.1.2.1.6 | INTEGER | read-write | Alert handling of Audible Alarm of in case of max. alarm condition of temperature sensor 1: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupTemp1AudibleAlarmMin | 1.3.6.1.4.1.232.153.2.2.2.1.2.1.7 | INTEGER | read-write | Alert handling of Audible Alarm of in case of min. alarm condition of temperature sensor 1: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupTemp1AudibleAlarmWarn | 1.3.6.1.4.1.232.153.2.2.2.1.2.1.5 | INTEGER | read-write | Alert handling of Audible Alarm of in case of warning condition of temperature sensor 1: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupTemp1Avail | 1.3.6.1.4.1.232.153.2.2.2.1.2.1.1 | INTEGER | read-write | Temperature sensor: (2) sensor available (3) sensor not available |
| INT cpqCmcSetupTemp1RelaysMax | 1.3.6.1.4.1.232.153.2.2.2.1.2.1.3 | INTEGER | read-write | Alert handling of Alarm Relays in case of max. alarm condition of temperature sensor 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupTemp1RelaysMin | 1.3.6.1.4.1.232.153.2.2.2.1.2.1.4 | INTEGER | read-write | Alert handling of Alarm Relays in case of min. alarm condition of temperature sensor 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupTemp1RelaysWarn | 1.3.6.1.4.1.232.153.2.2.2.1.2.1.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of warning condition of temperature sensor 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| cpqCmcSetupTemp2 | 1.3.6.1.4.1.232.153.2.2.2.1.2.2 | |||
| INT cpqCmcSetupTemp2AudibleAlarmMax | 1.3.6.1.4.1.232.153.2.2.2.1.2.2.6 | INTEGER | read-write | Alert handling of Audible Alarm of in case of max. alarm condition of temperature sensor 2: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupTemp2AudibleAlarmMin | 1.3.6.1.4.1.232.153.2.2.2.1.2.2.7 | INTEGER | read-write | Alert handling of Audible Alarm of in case of min. alarm condition of temperature sensor 2: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupTemp2AudibleAlarmWarn | 1.3.6.1.4.1.232.153.2.2.2.1.2.2.5 | INTEGER | read-write | Alert handling of Audible Alarm of in case of warning condition of temperature sensor 2: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupTemp2Avail | 1.3.6.1.4.1.232.153.2.2.2.1.2.2.1 | INTEGER | read-write | Temperature sensor: (2) sensor available (3) sensor not available |
| INT cpqCmcSetupTemp2RelaysMax | 1.3.6.1.4.1.232.153.2.2.2.1.2.2.3 | INTEGER | read-write | Alert handling of Alarm Relays in case of max. alarm condition of temperature sensor 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupTemp2RelaysMin | 1.3.6.1.4.1.232.153.2.2.2.1.2.2.4 | INTEGER | read-write | Alert handling of Alarm Relays in case of min. alarm condition of temperature sensor 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupTemp2RelaysWarn | 1.3.6.1.4.1.232.153.2.2.2.1.2.2.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of warning condition of temperature sensor 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| cpqCmcSetupThreshold | 1.3.6.1.4.1.232.153.2.2.2.2 | |||
| STR cpqCmcSetupTime | 1.3.6.1.4.1.232.153.2.2.2.1.3.2 | DisplayString | read-write | actual Time in format HH:MM:SS, HH (0-23), MM (0-59), SS (0-59) |
| cpqCmcSetupVoltage | 1.3.6.1.4.1.232.153.2.2.2.1.2.5 | |||
| INT cpqCmcSetupVoltageAudibleAlarmMax | 1.3.6.1.4.1.232.153.2.2.2.1.2.5.4 | INTEGER | read-write | Alert handling of Audible Alarm of in case of max. alarm condition of voltage monitoring: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupVoltageAudibleAlarmMin | 1.3.6.1.4.1.232.153.2.2.2.1.2.5.5 | INTEGER | read-write | Alert handling of Audible Alarm of in case of min. alarm condition of voltage monitoring: (2) Start Audible Alarm (3) No Audible Alarm |
| INT cpqCmcSetupVoltageAvail | 1.3.6.1.4.1.232.153.2.2.2.1.2.5.1 | INTEGER | read-write | Voltage monitoring: (2) available (3) not available |
| INT cpqCmcSetupVoltageRelaysMax | 1.3.6.1.4.1.232.153.2.2.2.1.2.5.2 | INTEGER | read-write | Alert handling of Alarm Relays in case of max. alarm condition of voltage monitoring: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| INT cpqCmcSetupVoltageRelaysMin | 1.3.6.1.4.1.232.153.2.2.2.1.2.5.3 | INTEGER | read-write | Alert handling of Alarm Relays in case of min. alarm condition of voltage monitoring: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch |
| cpqCmcStatus | 1.3.6.1.4.1.232.153.2.2.4 | |||
| STR cpqCmcStatusAccess | 1.3.6.1.4.1.232.153.2.2.5.1 | DisplayString | read-write | Status access, for future use |
| INT cpqCmcStatusAlarm1 | 1.3.6.1.4.1.232.153.2.2.4.17 | INTEGER | read-only | Status of alarm 1, see cmpCmcsetAlarm1. This alarm can be set from the Network management system. A descriptional text for this alarm can be set in cpqCmcSetupAlarm1Description. |
| INT cpqCmcStatusAlarm2 | 1.3.6.1.4.1.232.153.2.2.4.18 | INTEGER | read-only | Status of alarm 2, see cmpCmcsetAlarm2. This alarm can be set from the Network management system. A descriptional text for this alarm can be set in cpqCmcSetupAlarm2Description. |
| INT cpqCmcStatusAux1 | 1.3.6.1.4.1.232.153.2.2.4.15 | INTEGER | read-only | Status aux. digital input |
| INT cpqCmcStatusAux2 | 1.3.6.1.4.1.232.153.2.2.4.16 | INTEGER | read-only | Status aux. digital input |
| INT cpqCmcStatusFan1 | 1.3.6.1.4.1.232.153.2.2.4.3 | INTEGER | read-only | The status of fan 1: (2) fan is switched off by temperature sensor 1 (3) fan is switched on by temperature sensor 1 (4) fan is switched off by Manual Control (cpqCmcSetFan1) (5) fan is switched on by Manual Control (cpqCmcSetFan1) (6) fan is switched off because of smoke alarm (7) fan is switched off because door is open (8) no fan (9) fan error, current monitoring |
| INT cpqCmcStatusFan2 | 1.3.6.1.4.1.232.153.2.2.4.4 | INTEGER | read-only | The status of fan 2: (2) fan is switched off by temperature sensor 2 (3) fan is switched on by temperature sensor 2 (4) fan is switched off by Manual Control (cpqCmcSetFan2) (5) fan is switched on by Manual Control (cpqCmcSetFan2) (6) fan is switched off because of smoke alarm (7) fan is switched off because door is open (8) no fan (9) fan error, current monitoring |
| INT cpqCmcStatusHumidity | 1.3.6.1.4.1.232.153.2.2.4.6 | INTEGER | read-only | The humidity-status, see thresholds of humidity: (2) humidity normal (3) humidity exceeds max. threshold (4) humidity drops under min. threshold (5) no sensor connected, not available (6) error, sensor disconnected |
| INT cpqCmcStatusInput1 | 1.3.6.1.4.1.232.153.2.2.4.7 | INTEGER | read-only | The status of door/sidepanel 1, closed (2), open (3) or no sensor connected (4) |
| INT cpqCmcStatusInput2 | 1.3.6.1.4.1.232.153.2.2.4.8 | INTEGER | read-only | The status of door/sidepanel 2, closed (2), open (3) or no sensor connected (4) |
| INT cpqCmcStatusInput3 | 1.3.6.1.4.1.232.153.2.2.4.9 | INTEGER | read-only | The status of door/sidepanel 3, closed (2), open (3) or no sensor connected (4) |
| INT cpqCmcStatusInput4 | 1.3.6.1.4.1.232.153.2.2.4.10 | INTEGER | read-only | The status of door/sidepanel 4, closed (2), open (3) or no sensor connected (4) |
| INT cpqCmcStatusLock1Dev | 1.3.6.1.4.1.232.153.2.2.4.19 | INTEGER | read-only | The status of door-locking device 1 (2) OK (3) Power fail of door locking-device (4) Low Battery of door locking-device (5) Battery of door locking device needs to be replaced (6) Battery missing, insert all batteries (7) Connection CMC->door locking device lost (8) Lock not installed |
| INT cpqCmcStatusLock1Lock | 1.3.6.1.4.1.232.153.2.2.4.11 | INTEGER | read-only | The status of door locking 1 (2) Door locking-device is activated, door is locked (3) Door locking-device is not activated, door is unlocked by Network Management (4) Door locking-device is not activated for x sec, time see cpqCmcSetupLock1Time, door is unlocked by Network Management (5) Door locking-device is not activated, door is unlocked because of Smoke alarm (6) Door is unlocked from remote-signal (7) Door locking-device is not activated, door is unlocked because of Power Fail of locking device (8) Door locking-device is not activated, door is unlocked because of low Battery of locking device (9) Door locking-device is not activated, door is unlocked because of Network Fail (10)Door locking-device is not activated, door is unlocked because of connection fail, no connection locking device CMC (11)Door locking-device is ready to lock, lock will be activated after doors are closed (12)Door locking-device is activated but door is not locked, alarm (13)Configuration error, association door to locking-device missing (14)Lock not installed |
| INT cpqCmcStatusLock2Dev | 1.3.6.1.4.1.232.153.2.2.4.20 | INTEGER | read-only | The status of door-locking device 2 (2) OK (3) Power fail of door locking-device (4) Low Battery of door locking-device (5) Battery of door locking device needs to be replaced (6) Battery missing, insert all batteries (6) Connection CMC->door locking device lost (7) Lock not installed |
| INT cpqCmcStatusLock2Lock | 1.3.6.1.4.1.232.153.2.2.4.12 | INTEGER | read-only | The status of door locking 2 (2) Door locking-device is activated, door is locked (3) Door locking-device is not activated, door is unlocked by Network Management (4) Door locking-device is not activated for x sec, time see cpqCmcSetupLock1Time, door is unlocked by Network Management (5) Door locking-device is not activated, door is unlocked because of Smoke alarm (6) Door is unlocked from remote-signal (7) Door locking-device is not activated, door is unlocked because of Power Fail of locking device (8) Door locking-device is not activated, door is unlocked because of low Battery of locking device (9) Door locking-device is not activated, door is unlocked because of Network Fail (10)Door locking-device is not activated, door is unlocked because of connection fail, no connection locking device CMC (11)Door locking-device is ready to lock, lock will be activated after doors are closed (12)Door locking-device is activated but door is not locked, alarm (13)Configuration error, association door to locking-device missing (14)Lock not installed |
| INT cpqCmcStatusShock | 1.3.6.1.4.1.232.153.2.2.4.14 | INTEGER | read-only | Status Shock sensor, OK (2), shock detected (3) or no sensor connected (4) |
| INT cpqCmcStatusSmoke | 1.3.6.1.4.1.232.153.2.2.4.13 | INTEGER | read-only | Status smoke-sensor, OK (2), smoke detected (3) or no sensor connected (4) |
| INT cpqCmcStatusTemp1 | 1.3.6.1.4.1.232.153.2.2.4.1 | INTEGER | read-only | The status of temperature 1, see thresholds of temperature 1: (2) temperature normal (3) temperature exceeds warning threshold (4) temperature exceeds max. threshold (5) temperature drops under min. threshold (6) no sensor connected, not available (7) error, sensor disconnected |
| INT cpqCmcStatusTemp2 | 1.3.6.1.4.1.232.153.2.2.4.2 | INTEGER | read-only | The status of temperature 2, see thresholds of temperature 2: (2) temperature normal (3) temperature exceeds warning threshold (4) temperature exceeds max. threshold (5) temperature drops under min. threshold (6) no sensor connected, not available (7) error, sensor disconnected |
| INT cpqCmcStatusVoltage | 1.3.6.1.4.1.232.153.2.2.4.5 | INTEGER | read-only | The voltage-status, see thresholds of power supply: (2) voltage normal (3) voltage exceeds max. threshold (4) voltage drops under min. threshold (5) no power connected |
| INT cpqCmcThresholdFan1 | 1.3.6.1.4.1.232.153.2.2.2.2.7 | INTEGER | read-write | Threshold Fan 1 in deg F or deg C, Fan 1 will start if temperature 1 exceeds this value |
| INT cpqCmcThresholdFan1Hysteresis | 1.3.6.1.4.1.232.153.2.2.2.2.8 | INTEGER | read-write | Hystersis of Fan 1, Fan 1 will stop if temperature 1 falls below value of cpqCmcThresholdFan1 minus cpqCmcThresholdFan1Hysteresis |
| INT cpqCmcThresholdFan2 | 1.3.6.1.4.1.232.153.2.2.2.2.9 | INTEGER | read-write | Threshold Fan 2 in deg F or deg C, Fan 2 will start if temperature 2 exceeds this value |
| INT cpqCmcThresholdFan2Hysteresis | 1.3.6.1.4.1.232.153.2.2.2.2.10 | INTEGER | read-write | Hystersis of Fan 2, Fan 2 will stop if temperature 2 falls below value of cpqCmcThresholdFan2 minus cpqCmcThresholdFan2Hysteresis |
| INT cpqCmcThresholdMaxHumidity | 1.3.6.1.4.1.232.153.2.2.2.2.13 | INTEGER | read-write | Threshold high value Humidity alarm |
| INT cpqCmcThresholdMaxTemp1 | 1.3.6.1.4.1.232.153.2.2.2.2.1 | INTEGER | read-write | Threshold value maximum temperature 1 |
| INT cpqCmcThresholdMaxTemp2 | 1.3.6.1.4.1.232.153.2.2.2.2.4 | INTEGER | read-write | Threshold value maximum temperature 2 |
| INT cpqCmcThresholdMaxVoltage | 1.3.6.1.4.1.232.153.2.2.2.2.11 | INTEGER | read-write | Threshold high value Voltage alarm |
| INT cpqCmcThresholdMinHumidity | 1.3.6.1.4.1.232.153.2.2.2.2.14 | INTEGER | read-write | Threshold low value Humidity alarm |
| INT cpqCmcThresholdMinTemp1 | 1.3.6.1.4.1.232.153.2.2.2.2.3 | INTEGER | read-write | Threshold value minimum temperature 1 |
| INT cpqCmcThresholdMinTemp2 | 1.3.6.1.4.1.232.153.2.2.2.2.6 | INTEGER | read-write | Threshold value minimum temperature 2 |
| INT cpqCmcThresholdMinVoltage | 1.3.6.1.4.1.232.153.2.2.2.2.12 | INTEGER | read-write | Threshold low value Voltage alarm |
| INT cpqCmcThresholdWarningTemp1 | 1.3.6.1.4.1.232.153.2.2.2.2.2 | INTEGER | read-write | Threshold value warning temperature 1 |
| INT cpqCmcThresholdWarningTemp2 | 1.3.6.1.4.1.232.153.2.2.2.2.5 | INTEGER | read-write | Threshold value warning temperature 2 |
| cpqCmcTrapEntry | 1.3.6.1.4.1.232.153.2.2.2.3.2.1 | not-accessible | Entries of trapTable | |
| INT cpqCmcTrapIndex | 1.3.6.1.4.1.232.153.2.2.2.3.2.1.1 | INTEGER | read-only | Index for the trap-receiver-table. Its value ranges between 1 and the value of cpqCmcTrapTableNumber |
| STR cpqCmcTrapIPaddress | 1.3.6.1.4.1.232.153.2.2.2.3.2.1.3 | DisplayString | read-write | IP-address of trap-receiver |
| cpqCmcTraps | 1.3.6.1.4.1.232.153.2.2.2.3 | |||
| INT cpqCmcTrapStatus | 1.3.6.1.4.1.232.153.2.2.2.3.2.1.2 | INTEGER | read-write | Enable or disable trap receiver |
| cpqCmcTrapTable | 1.3.6.1.4.1.232.153.2.2.2.3.2 | not-accessible | A list of trap-receiver entries | |
| INT cpqCmcTrapTableNumber | 1.3.6.1.4.1.232.153.2.2.2.3.1 | INTEGER | read-only | Number of trapTable entries. The number of trap-receivers |
| INT cpqCmcValueHumidity | 1.3.6.1.4.1.232.153.2.2.3.4 | INTEGER | read-only | Actual value of humidity 0..100% |
| STR cpqCmcValueOperatingTime | 1.3.6.1.4.1.232.153.2.2.3.5 | DisplayString | read-only | Operating time CMC-unit |
| cpqCmcValues | 1.3.6.1.4.1.232.153.2.2.3 | |||
| INT cpqCmcValueTemp1 | 1.3.6.1.4.1.232.153.2.2.3.1 | INTEGER | read-only | Actual temperature value of temperature sensor 1 in deg C or deg F |
| INT cpqCmcValueTemp2 | 1.3.6.1.4.1.232.153.2.2.3.2 | INTEGER | read-only | Actual temperature value of temperature sensor 2 in deg C or deg F |
| INT cpqCmcValueVoltage | 1.3.6.1.4.1.232.153.2.2.3.3 | INTEGER | read-only | Actual value of power supply (voltage monitoring and fans) in V |
RFC description
Compaq/HPE vendor-private MIB for management module and chassis monitoring on ProLiant servers.
Start monitoring Legacy Compaq (HP) Cluster/Console Management Card with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.