All MIBs › CADANT-CMTS-EQUIPMENT-MIB
Organization: ARRIS Group, Inc.
Last Updated: 2015-10-06
Category: DOCSIS and Cable, Hardware and Environment, Vendor: ARRIS
Description:
Tracks hardware components such as cards, fans, and power supplies within ARRIS/Cadant CMTS chassis equipment.
Imported Objects
From CADANT-PRODUCTS-MIB
| cadEquipment | OBJECT-IDENTITY |
From CADANT-TC
| AdminState | |
| CardId | |
| CerCardSubType | |
| CerCardType | |
| CerPicType | |
| CerPortType | |
| DiskVolumeUsageLevel | |
| DuplexStatus | |
| EqActionType | |
| FirmwareSource | |
| FlowControlMode | |
| PicType | |
| PortDetectedMode | |
| PortId | |
| PortMode | |
| PortType | |
| PrimaryState | |
| SecondaryState |
From DOCS-IF-MIB
| TenthdBmV |
From IF-MIB
| InterfaceIndexOrZero | |
| ifIndex | OBJECT-TYPE |
From SNMP-FRAMEWORK-MIB
| SnmpAdminString |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| TimeTicks | |
| Unsigned32 |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| MacAddress | |
| RowStatus | |
| TEXTUAL-CONVENTION | |
| TimeStamp | |
| TruthValue |
What Is CADANT-CMTS-EQUIPMENT-MIB?
CADANT-CMTS-EQUIPMENT-MIB is a vendor-specific MIB from Cadant (acquired by ARRIS) used to manage and monitor the hardware equipment of the Arris/Cadant E6 Cable Modem Termination System (CMTS) chassis used in cable broadband networks. It exposes hardware inventory and status data covering cards, ports, disk drives, disk volumes, and shelf-level objects, along with system clock, diagnostic test, and auditing configuration, plus a dedicated equipment trap group. In monitoring terms it directly supports hardware health monitoring -- tracking card and port presence/status, disk drive and volume health, and equipment-related fault traps with configurable severity (trapSeverity) -- making it central to detecting failed cards, degraded disks, or chassis-level faults on the CMTS, which is why CADANT-CMTS-EQUIPMENT-MIB SNMP monitoring is typically scheduled at short polling intervals on production chassis where hardware faults directly affect subscriber-facing service. It is a self-contained equipment MIB that works alongside other CADANT MIBs (such as CADANT-SHOWCM-FORMAT-MIB) covering cable-modem-specific functionality on the same platform. It would typically be deployed on Arris/Cadant E6 CMTS chassis at a cable operator's headend or hub site.
IPNetwork Monitor allows you to monitor SNMP objects defined in CADANT-CMTS-EQUIPMENT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
What Can Be Monitored
- card and port operational status
- disk drive/volume health
- equipment trap count and severity
- system clock synchronization
- shelf-level status
Supported Devices
- Arris/Cadant E6 CMTS chassis
Monitoring Examples
An administrator would poll cardNumber and portNumber alongside the equipmentTraps group to detect when a line card or port has failed or been removed, and would check diskDriveNumber/diskVolumeNumber objects to confirm local storage health on the CMTS. The trapCounter and trapSeverity objects let an operator gauge how many equipment faults have fired and at what urgency, useful for prioritizing response to a chassis showing repeated high-severity equipment traps. systemClock would be checked to confirm the CMTS's internal clock is synchronized, since a drifted clock can skew trap timestamps during incident investigation.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| cadEquipmentMib | 1.3.6.1.4.1.4998.1.1.10.1 | This MIB is intended to describe all objects which are used to control and report on the state of an Arris E6 CMTS. These objects are used to perform the following functions on an Arris E6 CMTS: a) provision the cards, ports, and the CMTS itself b) run dianostic tests c) configure auditing parameters d) receive equipment-related traps | ||
| equipmentTraps | 1.3.6.1.4.1.4998.1.1.10.1.0 | |||
| NTF cmResetClearNotification | 1.3.6.1.4.1.4998.1.1.10.1.0.15 | This trap is sent when a CM is on-line from previous flap. | ||
| NTF cmResetNotification | 1.3.6.1.4.1.4998.1.1.10.1.0.16 | This trap is sent when a CM is reset. | ||
| NTF cardTempOutOfRangeNotification | 1.3.6.1.4.1.4998.1.1.10.1.0.19 | This trap is sent when the card temperature is out of range. | ||
| NTF cardTempNoReportNotification | 1.3.6.1.4.1.4998.1.1.10.1.0.20 | This trap is sent when there is no reporting on card temperature. | ||
| NTF cardTempOverHeatNotification | 1.3.6.1.4.1.4998.1.1.10.1.0.21 | This trap is sent when the card is overheat, card is being shut down. | ||
| NTF downstreamPowerLoss | 1.3.6.1.4.1.4998.1.1.10.1.0.22 | This trap is sent when c4 detects the loss of downstream power. | ||
| NTF cmRegistrationNotification | 1.3.6.1.4.1.4998.1.1.10.1.0.23 | This trap is sent when a CM is registered. | ||
| NTF noLicenseNotification | 1.3.6.1.4.1.4998.1.1.10.1.0.24 | This trap is sent when a channel cannot be activated due to insufficient license level. | ||
| NTF cerCardPrStateChange | 1.3.6.1.4.1.4998.1.1.10.1.0.25 | This trap is sent whenever the card's Primary state changes. | ||
| NTF cerCardSecStateChange | 1.3.6.1.4.1.4998.1.1.10.1.0.26 | This trap is sent whenever the card's Secondary state changes. | ||
| NTF cerCardDetectedChange | 1.3.6.1.4.1.4998.1.1.10.1.0.27 | This trap is sent whenever a new card is detected. | ||
| NTF cerCardDplxStatusChange | 1.3.6.1.4.1.4998.1.1.10.1.0.28 | This trap is sent whenever the card's Duplex status changes. | ||
| NTF cerPortPrStateChange | 1.3.6.1.4.1.4998.1.1.10.1.0.29 | This trap is sent whenever the port's Primary state changes. | ||
| NTF cerPortSecStateChange | 1.3.6.1.4.1.4998.1.1.10.1.0.30 | This trap is sent whenever the port's Secondary state changes. | ||
| NTF cerPortDplxStatusChange | 1.3.6.1.4.1.4998.1.1.10.1.0.31 | This trap is sent whenever the port's Duplex status changes. | ||
| NTF cardTestResultNotification | 1.3.6.1.4.1.4998.1.1.10.1.0.33 | This trap is sent when a test or diagnostic completed on a card. | ||
| NTF cerDiskVolumeUsageNotification | 1.3.6.1.4.1.4998.1.1.10.1.0.35 | This trap is sent when a disk volume usage level exceed a disk usage threshold. | ||
| NTF cerDiskVolumeAutoDeleteFileNotification | 1.3.6.1.4.1.4998.1.1.10.1.0.36 | This trap is sent when a file is automatically deleted by the system in respond to disk volume usage exceed critical thresholh. | ||
| cerCamFaultInfo | 1.3.6.1.4.1.4998.1.1.10.1.0.40 | |||
| CER cerCamFaultId | 1.3.6.1.4.1.4998.1.1.10.1.0.40.1 | CerCamFaultTrapType | accessible-for-notify | Type of CAM fault trigging the trap. |
| T/F cerCamFaultRecovery | 1.3.6.1.4.1.4998.1.1.10.1.0.40.2 | TruthValue | accessible-for-notify | True if recovery for this event is enabled. |
| T/F cerCamFaultAutoFailback | 1.3.6.1.4.1.4998.1.1.10.1.0.40.3 | TruthValue | accessible-for-notify | True if autofailback is enabled and the maximum failbacks have not occurred. |
| STR cerCamFaultErrorStr | 1.3.6.1.4.1.4998.1.1.10.1.0.40.4 | DisplayString | accessible-for-notify | Extra information about this error. Null string if no extra info. |
| NTF cerCamFaultNotification | 1.3.6.1.4.1.4998.1.1.10.1.0.41 | This trap is sent when a CAM has a fault of the specified type, even if fault recovery is inhibited for that fault type. | ||
| systemGeneral | 1.3.6.1.4.1.4998.1.1.10.1.1 | |||
| DAT systemClock | 1.3.6.1.4.1.4998.1.1.10.1.1.1 | DateAndTime | accessible-for-notify | CMTS local date and time displayed as yyyy-mm-dd,hh:mm:ss.d,+/-hh:mm, where the date is yyyy-mmmm-dd and time in deci-seconds is hh:mm:ss.d, adn teh current offset from GMT is +/-hh:mm. This object is adjusted by teh TZ and DST rules. E.g. 2002-5-26,13;30:15.0,-4:0 |
| C32 trapCounter | 1.3.6.1.4.1.4998.1.1.10.1.1.2 | Counter32 | read-only | This is the trap sequence number that increments each time a trap is sent. It is persistent across resets. |
| INT trapSeverity | 1.3.6.1.4.1.4998.1.1.10.1.1.3 | INTEGER | read-only | Severity level of a Cadant trap. |
| STR systemKey | 1.3.6.1.4.1.4998.1.1.10.1.1.4 | DisplayString | read-only | The systemKey is a unique string used for Candant's CMTS identification. The EMS uses this key string as well as the sysOid in the MIB-II system group MIB to identify Candant's CMTS's. |
| CAR cardNumber | 1.3.6.1.4.1.4998.1.1.10.1.1.98 | CardId | accessible-for-notify | Card Id used in traps. A value 99 indicates an invalid cardNumber. |
| POR portNumber | 1.3.6.1.4.1.4998.1.1.10.1.1.99 | PortId | accessible-for-notify | Port Id used in traps. A value of 99 indicates an invalid portNumber. |
| I32 diskDriveNumber | 1.3.6.1.4.1.4998.1.1.10.1.1.100 | Integer32 | accessible-for-notify | Disk drive ID use in a Cadant trap. A value of 99 indicates an invalid diskDriveNumber |
| I32 diskVolumeNumber | 1.3.6.1.4.1.4998.1.1.10.1.1.101 | Integer32 | accessible-for-notify | Disk volume ID use in a Cadant trap. A value of 99 indicates an invalid diskVolumeNumber |
| CAR cerCardNumber | 1.3.6.1.4.1.4998.1.1.10.1.1.200 | CardId | accessible-for-notify | Card Id used in traps. A value 0 indicates an invalid cardNumber. |
| POR cerPortNumber | 1.3.6.1.4.1.4998.1.1.10.1.1.201 | PortId | accessible-for-notify | Port Id used in traps. A value of 0 indicates an invalid portNumber. |
| I32 cerDiskDriveNumber | 1.3.6.1.4.1.4998.1.1.10.1.1.202 | Integer32 | accessible-for-notify | Disk drive ID use in a Cadant trap. A value of 0 indicates an invalid diskDriveNumber |
| I32 cerDiskVolumeNumber | 1.3.6.1.4.1.4998.1.1.10.1.1.203 | Integer32 | accessible-for-notify | Disk volume ID use in a Cadant trap. A value of 0 indicates an invalid diskVolumeNumber |
| shelfObjects | 1.3.6.1.4.1.4998.1.1.10.1.2 | |||
| STR shelfName | 1.3.6.1.4.1.4998.1.1.10.1.2.2 | DisplayString | read-write | A string that represents the name of this machine and may uniquely identify it from other network devices. |
| STR shelfSwVersion | 1.3.6.1.4.1.4998.1.1.10.1.2.3 | DisplayString | read-only | The software version currently executing. |
| equipmentState | 1.3.6.1.4.1.4998.1.1.10.1.3 | |||
| TIM cardLastChangeTime | 1.3.6.1.4.1.4998.1.1.10.1.3.2 | TimeStamp | read-only | The value of sysUpTime at the time any of the objects in cardTable last changed. |
| TIM portLastChangeTime | 1.3.6.1.4.1.4998.1.1.10.1.3.3 | TimeStamp | read-only | The value of sysUpTime at the time any of the objects in portTable last changed. |
| equipmentTbl | 1.3.6.1.4.1.4998.1.1.10.1.4 | |||
| cerCardTable | 1.3.6.1.4.1.4998.1.1.10.1.4.12 | not-accessible | A table of card or circuit pack information. | |
| cerCardEntry | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1 | not-accessible | A conceptual row containing pertinent information about a card or a circuit pack. | |
| CAR cerCardId | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.2 | CardId | accessible-for-notify | The unique id of this card within the shelf. The convention of cardId is as follows: - Indices from 1 to 50 [1 - 50] are reserved for Circuit Packs. In this case, the cardId is 1 plus the 0-based slot number. - Indices from 51 to 98 [51 - 98] are reserved for Auxilliary Devices in within a shelf. Auxilliary Devices or Modules could be Fan Module, Power Module. In this case, the cerCardName and cerCardType indentify the Auxilliary Devices. Not all of row attributes are applicable for Auxilliary Devices. |
| STR cerCardName | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.3 | DisplayString | read-write | This is the name of the card, if it has one. |
| CER cerCardType | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.4 | CerCardType | read-only | The type of card, if any. For example Ecard, Fcard, Dcard or Ucard If the slot is empty, the value would be 'empty'. |
| CER cerCardSubType | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.5 | CerCardSubType | read-write | The cardType alone may not be specific enough to fully describe the type of card that is in this slot. For example, a card type of Dcard might have a more specific type of 1D8U with integrated upconverter. If the card needs no further specificication that the cardType, then the value of cardSubType is 'none'. Not yet implemented. |
| ADM cerCardAdminState | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.12 | AdminState | read-write | This is the administrative state of this card. |
| PRI cerCardPrState | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.13 | PrimaryState | read-only | This is the primary state of this card. |
| SEC cerCardSecState | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.14 | SecondaryState | read-only | This is the secondary state of this card. |
| DUP cerCardDplxStatus | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.15 | DuplexStatus | read-only | This is the duplexing status of this card. |
| EQA cerCardAction | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.17 | EqActionType | read-write | Write-only action performed on this card. |
| BIT cerCardTrapInh | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.18 | Bits | read-write | If a bit is set, the corresponding state change trap will not be sent. |
| I32 cerCardNumPorts | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.19 | Integer32 | read-only | Number of ports this card contains. |
| CER cerCardDetected | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.20 | CerCardType | read-only | CardType dectected automatically by the CMTS. |
| CER cerCardSubDetected | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.21 | CerCardSubType | read-only | CardSubType dectected automatically by the CMTS. |
| T/F cerCardFwUpdateStatus | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.23 | TruthValue | read-only | Set to TRUE if a firmware update is in progress or has been done, else set to FALSE. |
| CAR cerCardSpareGroupId | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.24 | CardId | read-write | The cardId of the spare group leader for this sparing group. This value will be set to the invalid card id for all cards not associated with a sparing group. |
| INT cerCardSpareGroupMode | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.25 | INTEGER | read-write | The admin mode of the spare group leader for this sparing group. This value will be set to the invalid card id for all cards not associated with a sparing group. |
| TIK cerCardUpTime | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.26 | TimeTicks | read-only | The value of sysUpTime when the primary state for this card made a transition from OOS to IS. |
| I32 cerCardTemperature | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.29 | Integer32 | read-only | The current relative temperature of the card. (1=coolest, 10=hottest) |
| CER cerCardPicDetected | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.40 | CerPicType | read-only | The type of PIC detected in this slot. |
| STR cerCardLastResetReason | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.43 | DisplayString | read-only | The reason for the latest card recovery. |
| I32 cerCardTemperatureHighWarn | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.44 | Integer32 | read-write | The relative temperature of the card at which warnings are generated. |
| I32 cerCardTemperatureHighError | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.45 | Integer32 | read-write | The relative temperature of the card at which recoveries are initiated. |
| INT cerCardAnnex | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.46 | INTEGER | read-only | The annex of the downstream channels associated with the card. |
| I32 cerCardNumRfConnectors | 1.3.6.1.4.1.4998.1.1.10.1.4.12.1.47 | Integer32 | read-only | Number of RF ports this card contains. |
| cerPortTable | 1.3.6.1.4.1.4998.1.1.10.1.4.13 | not-accessible | A table of Port information. | |
| cerPortEntry | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1 | not-accessible | A conceptual row containing pertinent information about a cerPort owned by a card. | |
| CAR cerPortCardId | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.2 | CardId | not-accessible | The unique id of the card this cerPort belongs to. |
| POR cerPortId | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.3 | PortId | not-accessible | The unique id of this cerPort within a card. the the cardId and cerPortId uniquely identify a port |
| CER cerPortType | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.4 | CerPortType | read-write | Type of this cerPort. |
| ADM cerPortAdminState | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.6 | AdminState | read-write | The Admin state of this cerPort |
| PRI cerPortPrState | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.7 | PrimaryState | read-only | The primary state of this cerPort |
| SEC cerPortSecState | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.8 | SecondaryState | read-only | The secondary state of this cerPort |
| DUP cerPortDplxStatus | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.9 | DuplexStatus | read-only | The port Duplexing status. |
| EQA cerPortAction | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.11 | EqActionType | read-write | Write-only action performed on a Port. |
| BIT cerPortTrapInh | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.12 | Bits | read-write | If a bit is set, the corresponding state change trap will not be sent. |
| I32 cerPortNumChans | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.13 | Integer32 | read-only | Number of channels this cerPort contains. |
| NUM cerPortDocsIfIndex | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.14 | InterfaceIndexOrZero | read-only | This object indicates the location of an interface in the cerPort table that represents this port. A value of 0 indicates that this cerPort does not have an association in the Iftable. |
| MAC cerPortMacAddress | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.15 | MacAddress | read-only | The physical address value for this card. This value is used to populate the ifPhysAddress field in the IfTable and other Tables in docsis RFC MIBs. |
| POR cerPortMode | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.16 | PortMode | read-write | The desired operating mode of an ethernet cerPort. Not yet implemented. |
| POR cerPortDetectedMode | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.17 | PortDetectedMode | read-only | The current operating mode of an ethernet cerPort. |
| I32 cerPortBgpId | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.19 | Integer32 | read-only | The bridge group cerPort id for this port. |
| POR cerPortConnectorId | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.20 | PortId | read-write | For a DOCSIS or EQAM type port, this is the rear PIC connector. Otherwise, the value of this object is invalid. |
| CER cerPortCardSubType | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.21 | CerCardSubType | read-only | The CardSubType of the card this cerPort belongs to. |
| STR cerPortDescription | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.27 | DisplayString | read-write | A persistent copy of ifAlias for this interface. |
| TEN cerPortCurrDsPower | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.28 | TenthdBmV | read-only | The latest downstream power level reported by the port. This is valid on for ports of type dport. |
| TEN cerPortMinDsPower | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.29 | TenthdBmV | read-only | The latest downstream power level recerPorted by the port. This is valid only for downstream ports. |
| TEN cerPortMaxDsPower | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.30 | TenthdBmV | read-only | The latest downstream power level recerPorted by the port. This is valid only for downstream ports. |
| FLO cerPortTxFlowControlMode | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.31 | FlowControlMode | read-write | The transmit flow control settings for this port (network ports only). |
| FLO cerPortRxFlowControlMode | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.32 | FlowControlMode | read-write | The receive flow control settings for this port (network ports only). |
| FLO cerPortTxFlowControlDetected | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.33 | FlowControlMode | read-only | The recerPorted transmit flow control settings for this port (network ports only). |
| FLO cerPortRxFlowControlDetected | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.34 | FlowControlMode | read-only | The recerPorted receive flow control settings for this port (network ports only). |
| NUM cerPortMacIfIndex | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.35 | InterfaceIndexOrZero | read-only | The MAC IfIndex currently associcated with the upstream or downstream port. |
| POR cerPortGroupId | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.36 | PortId | read-only | The unique id of port group associated with this port. |
| POR cerPortGroupPortId | 1.3.6.1.4.1.4998.1.1.10.1.4.13.1.37 | PortId | read-only | The unique id of this port in the port group. |
| cerDiskVolumeTable | 1.3.6.1.4.1.4998.1.1.10.1.4.14 | not-accessible | A table of disk volume information. | |
| cerDiskVolumeEntry | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1 | not-accessible | A conceptual row containing pertinent information about a disk volume | |
| CAR cerDiskVolumeCardId | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.2 | CardId | not-accessible | The unique id of the card this disk volume belongs to. |
| I32 cerDiskVolumeDriveId | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.3 | Integer32 | not-accessible | The unique id of the disk drive this disk volume belongs to. A value of 99 indicates an invalid disk drive |
| I32 cerDiskVolumeId | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.4 | Integer32 | not-accessible | The unique id of this disk volume. the cerDiskVolumeCardId, the diskVolumeDiskId, and the. A value of 99 indicate an invalid volume |
| STR cerDiskVolumeName | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.5 | DisplayString | read-only | The name of the disk volume. |
| I32 cerDiskVolumeSize | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.6 | Integer32 | read-only | The disk volume size in units of 2048 bytes. |
| DIS cerDiskVolumeUsageLevel | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.7 | DiskVolumeUsageLevel | read-only | The disk volume usage level. |
| I32 cerDiskVolumeUsagePercentage | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.8 | Integer32 | read-only | The disk volume usage percentage. |
| I32 cerDiskVolumeUsageCriticalThreshold | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.9 | Integer32 | read-write | Usage percentage level when exceed will cause a cerDiskVolumeUsageNotification trap to be sent with cerDiskVolumeUsageLevel of diskVolumeUsageCritical. |
| I32 cerDiskVolumeUsageMajorThreshold | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.10 | Integer32 | read-write | Usage percentage level when exceed will cause a cerDiskVolumeUsageNotification trap to be sent with cerDiskVolumeUsageLevel of diskVolumeUsageMajor. |
| I32 cerDiskVolumeUsageMinorThreshold | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.11 | Integer32 | read-write | Usage percentage level when exceed will cause a cerDiskVolumeUsageNotification trap to be sent with cerDiskVolumeUsageLevel of diskVolumeUsageMinor. |
| T/F cerDiskVolumeAutoDeleteUnusedFile | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.12 | TruthValue | read-write | When set to TRUE to the system will automatically delete unused files when cerDiskVolumeUsage exceed the cerDiskVolumeUsageCriticalThreshold value. |
| BIT cerDiskVolumeTrapInh | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.13 | Bits | read-write | If a bit is set, the corresponding trap will not be sent. |
| I32 cerDiskVolumeDiskSize | 1.3.6.1.4.1.4998.1.1.10.1.4.14.1.14 | Integer32 | read-only | Total physical disk capacity in bytes. |
| STR cerDiskVolumeFileName | 1.3.6.1.4.1.4998.1.1.10.1.4.15 | DisplayString | accessible-for-notify | The name of a file on the disk volume use for trap notification. |
| cerCardDataTable | 1.3.6.1.4.1.4998.1.1.10.1.4.16 | not-accessible | This table shows the contains version information for the modules installed. | |
| cerCardDataEntry | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1 | not-accessible | A conceptual row containing pertinent information about a card or a circuit pack. | |
| STR cerCardDataSerialNum | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.1 | SnmpAdminString | read-only | This is the serial number of the card. |
| STR cerCardDataFwVersion | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.2 | SnmpAdminString | read-only | This is the firmware or FPGA version number of the card. |
| STR cerCardDataHwVersion | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.3 | SnmpAdminString | read-only | This is the hardware version of the card. |
| STR cerCardDataHwDeviations | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.4 | SnmpAdminString | read-only | This is the set of hardware deviations for the card. |
| STR cerCardDataSwVersion | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.5 | SnmpAdminString | read-only | This is the software version of the card. |
| STR cerCardDataCpuType | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.6 | SnmpAdminString | read-only | The current CPU type of the card. |
| U32 cerCardDataCpuSpeed | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.7 | Unsigned32 | read-only | The current CPU speed of the card. |
| U32 cerCardDataBusSpeed | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.8 | Unsigned32 | read-only | The current bus speed of the card. |
| U32 cerCardDataRamSize | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.9 | Unsigned32 | read-only | The current size of installed RAM of the card. |
| U32 cerCardDataNorFlashSize | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.10 | Unsigned32 | read-only | The current size of installed FLASH of the card. |
| U32 cerCardDataNandFlashSize | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.11 | Unsigned32 | read-only | The current size of installed FLASH of the card. |
| FIR cerCardDataFpgaSource | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.12 | FirmwareSource | read-only | The source of the running version of the FPGAs on the card. |
| STR cerCardDataBootVersion | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.13 | SnmpAdminString | read-only | The current versions of the boot loaders installed on the card. |
| STR cerCardDataLastBootVersion | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.14 | SnmpAdminString | read-only | The last version of the boot loader used on the card. |
| FIR cerCardDataLastBootSource | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.15 | FirmwareSource | read-only | The source of the version of the bootloader last used on the card. |
| STR cerCardDataPicSerialNum | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.16 | SnmpAdminString | read-only | This is the serial number of the PIC. |
| STR cerCardDataPicHwVersion | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.17 | SnmpAdminString | read-only | This is the hardware version of the PIC. |
| STR cerCardDataPicHwDeviations | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.18 | SnmpAdminString | read-only | This is the set of hardware deviations for the PIC. |
| STR cerCardDataPicModelNum | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.19 | SnmpAdminString | read-only | This is the model number of the PIC. |
| DAT cerCardDataMfgDateTime | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.20 | DateAndTime | read-only | Date of the module's manufacture (FRU). |
| STR cerCardDataMfg | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.21 | SnmpAdminString | read-only | Name of the manufacturer (FRU). |
| STR cerCardDataProductName | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.22 | SnmpAdminString | read-only | Name of the product (FRU). |
| STR cerCardDataPartModelNum | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.23 | SnmpAdminString | read-only | Name of the model of this product (FRU). |
| STR cerCardDataProductVersion | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.24 | SnmpAdminString | read-only | Version of the model of this product (FRU). |
| STR cerCardDataAssetTag | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.25 | SnmpAdminString | read-only | Asset tag of this part (FRU). |
| STR cerCardDataCommittedSwVersion | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.26 | SnmpAdminString | read-only | This is the software version of the card. |
| T/F cerCardDataFeedAPresent | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.27 | TruthValue | read-only | This object indicates whether power feed A is present or not. |
| T/F cerCardDataFeedBPresent | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.28 | TruthValue | read-only | This object indicates whether power feed B is present or not. |
| U32 cerCardDataAllowedPorts | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.29 | Unsigned32 | read-only | This object indicates the allowed number of licensed ports. |
| INT cerCardDataLicenseAnnex | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.30 | INTEGER | read-only | This object shows the annex associated with the license. |
| U32 cerCardDataLicensePorts | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.31 | Unsigned32 | read-only | This object indicates the number of ports associated with the license. |
| DAT cerCardDataLicenseDate | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.32 | DateAndTime | read-only | This object indicates the date associated with the license. |
| STR cerCardDataPatchVersions | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.33 | SnmpAdminString | read-only | This is the patch version(s) running on the card. |
| STR cerCardDataPicModelName | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.34 | SnmpAdminString | read-only | This is the model name of the PIC. |
| STR cerCardDataPicMfgRevision | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.35 | SnmpAdminString | read-only | This is the manufacture revision of the PIC. |
| STR cerCardDataPicMfg | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.36 | SnmpAdminString | read-only | This is the manufacturer of the PIC. |
| DAT cerCardDataPicMfgDateTime | 1.3.6.1.4.1.4998.1.1.10.1.4.16.1.37 | DateAndTime | read-only | This object indicates the date associated with the PIC. |
| cerFanStatusTable | 1.3.6.1.4.1.4998.1.1.10.1.4.17 | not-accessible | Status information for the E6 fans. | |
| cerFanStatusEntry | 1.3.6.1.4.1.4998.1.1.10.1.4.17.1 | not-accessible | A conceptual row containing information about one of the fans. | |
| I32 cerFan1Speed | 1.3.6.1.4.1.4998.1.1.10.1.4.17.1.1 | Integer32 | read-only | The last measured speed of fan1. |
| I32 cerFan2Speed | 1.3.6.1.4.1.4998.1.1.10.1.4.17.1.2 | Integer32 | read-only | The last measured speed of fan2. |
| I32 cerFan3Speed | 1.3.6.1.4.1.4998.1.1.10.1.4.17.1.3 | Integer32 | read-only | The last measured speed of fan3. |
| I32 cerFanLevel | 1.3.6.1.4.1.4998.1.1.10.1.4.17.1.4 | Integer32 | read-only | The last measured speed level of fans. |
| I32 cerFanAmbientTemperature | 1.3.6.1.4.1.4998.1.1.10.1.4.17.1.5 | Integer32 | read-only | The last measured ambient temperature of fans. |
| cerPemStatusTable | 1.3.6.1.4.1.4998.1.1.10.1.4.18 | not-accessible | PEM Status information for the E6 power modules. | |
| cerPemStatusEntry | 1.3.6.1.4.1.4998.1.1.10.1.4.18.1 | not-accessible | A conceptual row containing information about one of the power modules. | |
| INT cerPemLedStatus | 1.3.6.1.4.1.4998.1.1.10.1.4.18.1.1 | INTEGER | read-only | LED status of the PEM |
| I32 cerPemFeed1Voltage | 1.3.6.1.4.1.4998.1.1.10.1.4.18.1.2 | Integer32 | read-only | Feed 1 voltage |
| I32 cerPemFeed1Current | 1.3.6.1.4.1.4998.1.1.10.1.4.18.1.3 | Integer32 | read-only | Feed 1 current |
| I32 cerPemFeed2Voltage | 1.3.6.1.4.1.4998.1.1.10.1.4.18.1.4 | Integer32 | read-only | Feed 2 voltage |
| I32 cerPemFeed2Current | 1.3.6.1.4.1.4998.1.1.10.1.4.18.1.5 | Integer32 | read-only | Feed 2 current |
| T/F cerPemFeed1Present | 1.3.6.1.4.1.4998.1.1.10.1.4.18.1.6 | TruthValue | read-only | Feed 1 presence |
| T/F cerPemFeed2Present | 1.3.6.1.4.1.4998.1.1.10.1.4.18.1.7 | TruthValue | read-only | Feed 2 presence |
| T/F cerPemCircuitBreaker1Enable | 1.3.6.1.4.1.4998.1.1.10.1.4.18.1.8 | TruthValue | read-only | circuit breaker 1 presence |
| T/F cerPemCircuitBreaker2Enable | 1.3.6.1.4.1.4998.1.1.10.1.4.18.1.9 | TruthValue | read-only | circuit breaker 2 presence |
| BIT cerPemBranchPresent | 1.3.6.1.4.1.4998.1.1.10.1.4.18.1.10 | Bits | read-only | brach A through I presence |
| equipmentDiag | 1.3.6.1.4.1.4998.1.1.10.1.5 | |||
| eqDiagConfig | 1.3.6.1.4.1.4998.1.1.10.1.5.1 | |||
| T/F remainInDiagMode | 1.3.6.1.4.1.4998.1.1.10.1.5.1.1 | TruthValue | read-write | When set to TRUE, the device being diagnosed will remain in diagnostic state when the diagnostic test is completed. When set to FALSE, the device will revert to its original state when the diagnostic test is completed. |
| T/F consoleOutput | 1.3.6.1.4.1.4998.1.1.10.1.5.1.2 | TruthValue | not-accessible | If true then the diagnostic result will be displayed on the system console. |
| I32 verboseLevel | 1.3.6.1.4.1.4998.1.1.10.1.5.1.3 | Integer32 | read-write | Verbose output level for diagnostic console output display. Higher number indicate more detailed output. |
| TES diagTestId | 1.3.6.1.4.1.4998.1.1.10.1.5.2 | TestId | accessible-for-notify | Test Identification Number. Used in cardTestResultNotification variable-binding |
| cardTestTable | 1.3.6.1.4.1.4998.1.1.10.1.5.3 | not-accessible | A table of test available for a card. | |
| cardTestEntry | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1 | not-accessible | A conceptual row containing information about tests or dignostics available for a card. | |
| CAR cardTestIndex | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1.2 | CardId | not-accessible | Card Identification Number taken from the CardTable. Used as index. |
| TES cardTestId | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1.3 | TestId | not-accessible | Test Identification Number. Used as index to test table |
| STR cardTestName | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1.4 | DisplayString | read-only | A unique name for this test. |
| TES cardTestType | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1.5 | TestType | read-only | Test Type. |
| STR cardTestDescription | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1.6 | DisplayString | read-only | A short description of the test. |
| TES cardTestCommand | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1.7 | TestCommand | read-write | Command to be execute this test on this shelf |
| TES cardTestScheduleCommand | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1.8 | TestScheduleCommand | read-write | Schedule Command to be execute this test on this shelf |
| TES cardTestSchedule | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1.9 | TestSchedule | read-write | Test Scheduling. |
| DAT cardTestTime | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1.10 | DateAndTime | read-write | Test start time. |
| TES cardTestResult | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1.11 | TestResult | read-only | Result of the test. |
| STR cardTestResultDesc | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1.12 | DisplayString | read-only | Additional information of the test result. |
| TES cardTestTransId | 1.3.6.1.4.1.4998.1.1.10.1.5.3.1.13 | TestTransactionId | read-write | Test transaction Id. |
| equipmentAudit | 1.3.6.1.4.1.4998.1.1.10.1.6 | |||
| T/F auditAutoScheduling | 1.3.6.1.4.1.4998.1.1.10.1.6.1 | TruthValue | read-write | Enable or disable automatic audit execution. |
| T/F auditLogOutput | 1.3.6.1.4.1.4998.1.1.10.1.6.2 | TruthValue | read-write | Enable or disable logging of error entries to system log. |
| T/F auditLogThrottle | 1.3.6.1.4.1.4998.1.1.10.1.6.3 | TruthValue | read-write | Enable or disable audit log output throttling to prevent audit errors from flooding the log. |
| auditTable | 1.3.6.1.4.1.4998.1.1.10.1.6.4 | not-accessible | A table of test available for a card. | |
| auditEntry | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1 | not-accessible | A conceptual row contains information about Audits. | |
| CAR auditCardId | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.2 | CardId | not-accessible | Card Identification Number taken from the CardTable. Used as index. |
| U32 auditId | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.3 | Unsigned32 | not-accessible | Unique ID of the internal Audit |
| STR auditName | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.4 | DisplayString | read-only | Name of the internal Audit |
| STR auditDescription | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.5 | DisplayString | read-only | Description of the Audit |
| DAT auditTime | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.6 | DateAndTime | read-only | Start time of the audit. |
| INT auditCommand | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.7 | INTEGER | read-write | Audit Commands. The runnow command will stop the currently running audit sequence and start executing requested audit immediated. If enabled, automatic audit schedule will be restarted. |
| INT auditStatus | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.8 | INTEGER | read-only | Audit status. |
| INT auditResult | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.9 | INTEGER | read-only | Audit Result. |
| U32 auditPassedCount | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.10 | Unsigned32 | read-only | Number of passed entry during previous audit run. |
| U32 auditFailedCount | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.11 | Unsigned32 | read-only | Number of failed entry during previous audit run. |
| U32 auditCycleCount | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.12 | Unsigned32 | read-only | Number of audit run completed. |
| U32 auditTotalPassedCount | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.13 | Unsigned32 | read-only | Number of cumulative passed entry of all audit runs. |
| U32 auditTotalFailedCount | 1.3.6.1.4.1.4998.1.1.10.1.6.4.1.14 | Unsigned32 | read-only | Number of cumulative failed entry of all audit runs. |
| cmDevice | 1.3.6.1.4.1.4998.1.1.10.1.8 | |||
| MAC cmMacAddress | 1.3.6.1.4.1.4998.1.1.10.1.8.1 | MacAddress | accessible-for-notify | The MAC address for the cable modem |
| STR cmVendor | 1.3.6.1.4.1.4998.1.1.10.1.8.2 | DisplayString | accessible-for-notify | The vendor name of the cable modem |
| STR cmResetReason | 1.3.6.1.4.1.4998.1.1.10.1.8.3 | DisplayString | accessible-for-notify | The reason for the cable modem to reset |
| I32 cmUChannelID | 1.3.6.1.4.1.4998.1.1.10.1.8.4 | Integer32 | accessible-for-notify | The CMTS upstream channel ID which is connected to the cable modem |
| U32 cmPrimarySID | 1.3.6.1.4.1.4998.1.1.10.1.8.5 | Unsigned32 | accessible-for-notify | The primary Service Identifier (SID) assigned by the CMTS associated with the cable modem |
| STR cmResetStatus | 1.3.6.1.4.1.4998.1.1.10.1.8.6 | DisplayString | accessible-for-notify | The cable modem status before it resets |
| TIK cmResetUpTime | 1.3.6.1.4.1.4998.1.1.10.1.8.7 | TimeTicks | accessible-for-notify | This value indicates how long in hundreds of seconds the cable modem is up since it is initial ranged |
| STR cmResetInfo | 1.3.6.1.4.1.4998.1.1.10.1.8.8 | DisplayString | accessible-for-notify | The additional information for the cable modem to reset |
| OCT cmIpAddress | 1.3.6.1.4.1.4998.1.1.10.1.8.9 | OCTET STRING | accessible-for-notify | The IP Address of the cable modem |
| equipmentError | 1.3.6.1.4.1.4998.1.1.10.1.9 | |||
| fpgaErrorEventTable | 1.3.6.1.4.1.4998.1.1.10.1.9.1 | not-accessible | Overrides default handling of FPGA error events. | |
| fpgaErrorEventEntry | 1.3.6.1.4.1.4998.1.1.10.1.9.1.1 | not-accessible | A conceptual row containing information about FPGA error event handling. | |
| U32 errEventId | 1.3.6.1.4.1.4998.1.1.10.1.9.1.1.1 | Unsigned32 | not-accessible | Event ID associated with the FPGA error. A row in this table defines behavior for a specific FPGA error that overrides the default behavior of the system. |
| T/F errEvRecoveryEnabled | 1.3.6.1.4.1.4998.1.1.10.1.9.1.1.2 | TruthValue | read-create | If true, the card can be recovered when this FPGA error is detected. When the card is recovered depends on the setting of errEvRecoveryThreshold. If this value is false, the card will not be recovered when this error is detected. |
| T/F errEvLoggingEnabled | 1.3.6.1.4.1.4998.1.1.10.1.9.1.1.3 | TruthValue | read-create | If true, the card will provide notification of the occurance of the this error. When the notification occurs is dependent on the setting of errEvLogThrottleThreshold. The severity of the notification is determined by the setting of errEvLogLevel. |
| I32 errEvLogLevel | 1.3.6.1.4.1.4998.1.1.10.1.9.1.1.4 | Integer32 | read-create | If errEvLoggingEnabled is true, this setting sets the severity level of the generated notification. In general, higher values indicate lower severity. |
| ROW errEvRowStatus | 1.3.6.1.4.1.4998.1.1.10.1.9.1.1.5 | RowStatus | read-create | The only set actions supported on this table are createAndGo(4) and destroy(6). |
| CAR errEvCardId | 1.3.6.1.4.1.4998.1.1.10.1.9.1.1.6 | CardId | not-accessible | The unique id of this card within the shelf. |
| cadEquipmentMibConformance | 1.3.6.1.4.1.4998.1.1.10.1.10 | |||
| cadEquipmentMibCompliances | 1.3.6.1.4.1.4998.1.1.10.1.10.1 | |||
| cadEquipmentMibCompliance | 1.3.6.1.4.1.4998.1.1.10.1.10.1.1 | The compliance statement for entities which implement the Equipment MIB. | ||
| cadEquipmentMibGroup | 1.3.6.1.4.1.4998.1.1.10.1.10.2 | |||
| systemGeneralGroup | 1.3.6.1.4.1.4998.1.1.10.1.10.2.1 | This group contains a collection of objects general to the overall system. | ||
| equipmentStateGroup | 1.3.6.1.4.1.4998.1.1.10.1.10.2.2 | This group contains a collection of objects general to the state of the equipments. | ||
| equipmentShelfGroup | 1.3.6.1.4.1.4998.1.1.10.1.10.2.3 | This group contains a collection of objects general specific to shelf objects. | ||
| equipmentDiagGroup | 1.3.6.1.4.1.4998.1.1.10.1.10.2.6 | This group contains a collection of objects specific to equipment diagnostics. | ||
| equipmentCardTestGroup | 1.3.6.1.4.1.4998.1.1.10.1.10.2.8 | This group contains a collection of objects specific to card Test group | ||
| equipmentAuditGroup | 1.3.6.1.4.1.4998.1.1.10.1.10.2.10 | This group contains a collection of objects specific audit group. | ||
| fpgaErrorEventGroup | 1.3.6.1.4.1.4998.1.1.10.1.10.2.12 | This group contains a collection of objects dealing with FPGA errors. | ||
| equipmentCerCardGroup | 1.3.6.1.4.1.4998.1.1.10.1.10.2.14 | This group contains a collection of objects general specific to Card tables. | ||
| equipmentCerPortGroup | 1.3.6.1.4.1.4998.1.1.10.1.10.2.15 | This group contains a collection of objects specific to Port table. | ||
| cerDiskVolumeGroup | 1.3.6.1.4.1.4998.1.1.10.1.10.2.21 | This group contains a collection of objects specific to disk volume objects. | ||
| cerSpareModeExt | 1.3.6.1.4.1.4998.1.1.10.1.11 | |||
| cerSpareModeExtTable | 1.3.6.1.4.1.4998.1.1.10.1.11.1 | not-accessible | Allows overriding the configured sparing mode for a spare group based on the fault type that caused the sparing event. | |
| cerSpareModeExtEntry | 1.3.6.1.4.1.4998.1.1.10.1.11.1.1 | not-accessible | A conceptual row containing information about sparing overrides for a spare group. | |
| CAR cerSpareModeCardId | 1.3.6.1.4.1.4998.1.1.10.1.11.1.1.1 | CardId | not-accessible | The cardId of the spare group leader for this override. |
| INT cerSpareModeFaultId | 1.3.6.1.4.1.4998.1.1.10.1.11.1.1.2 | INTEGER | not-accessible | The fault group associated with the override behavior. When an event occurs that would normally trigger a card reset and a sparing event and that event is in the configured fault group, the mode configured in the cerCard table is overriden. pingFault - Communications failure with active controller initTimeout - Timeout during card initialization ersmFault - Card ERSM failure swException - Software exception failure bcm3142Err - Upstream CAM PHY device fatal fault condition dulFailure - Upstream CAM periodic packet loop detected uncorrectable fault dataplaneFailrue - Fatal errors originating in dataplane processor dsUnderPower - Downstream CAM detected power on a connector is below operational threshold dsOverPower - Downstream CAM detected power on a connector is above operational threshold sbecOverflow - Excessive number of single bit ECC errors deviceFatal - General device fatal error. For example in internal datapaths or pci controller. fpgaFatalError - Fatal CRC errors detected in FPGA device clockLost - Loss of clock or loss of clock lock pwrSensorHighFault - Detected voltage is above operational threshold pwrSensorLowFault - Detected voltage is below operational threshold fpgaBufferPoolFault - Number of available buffers in MAC fpga is below threshold dataplaneLinkFault - Card has lost dataplane connectivity monitoredTaskFailure - Monitored software task has failed |
| INT cerSpareModeMode | 1.3.6.1.4.1.4998.1.1.10.1.11.1.1.3 | INTEGER | read-create | The sparing mode that should be enforced when an error in the configured catagory occurs that results in a sparing event. |
| ROW cerSpareModeRowStatus | 1.3.6.1.4.1.4998.1.1.10.1.11.1.1.4 | RowStatus | read-create | The only set actions supported on this table are createAndGo(4) and destroy(6). |
| licenseError | 1.3.6.1.4.1.4998.1.1.10.1.12 | |||
| STR cerLicenseTypeStr | 1.3.6.1.4.1.4998.1.1.10.1.12.1 | DisplayString | accessible-for-notify | The license type that caused the notification. |
RFC description
Monitors hardware components including cards, fans, and power supplies in ARRIS/Cadant CMTS chassis equipment.
Start monitoring ARRIS/Cadant C4/E6000 CMTS (cable modem termination system) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.