All MIBs › CISCO-MGX82XX-SONET-MIB
Category: Cisco Devices, Hardware and Environment, Network Interfaces, Optical and WDM
Description: Manages SONET interface configuration and performance monitoring on Cisco MGX 8200 WAN switch line cards.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CISCO-MGX82XX-SONET-MIB?
CISCO-MGX82XX-SONET-MIB manages SONET interface configuration and Automatic Protection Switching (APS) on line cards within Cisco MGX 8200 series WAN switches. It belongs to the legacy carrier-grade WAN transport technology area, exposing objects for configuring working/protection line pairs, APS architecture mode, and switchover behavior between redundant SONET lines. Its data is centered on transmission-line fault and performance monitoring: apsSFBER and apsSDBER expose signal-fail and signal-degrade bit-error-rate thresholds, apsActiveLine reports which line is currently carrying traffic, and apsWtr tracks the wait-to-restore timer after a protection switch—together giving visibility into the physical health of the SONET transport and automatic failover behavior. This complements DS3/E3-focused sibling MIBs on the same MGX platform and depends on the general SONET/APS standards framework. It is deployed on Cisco MGX 8200 series switches providing carrier-grade SONET transport with 1+1 or similar protection schemes in service-provider backbone networks. Engineers can download the CISCO-MGX82XX-SONET-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in CISCO-MGX82XX-SONET-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Cisco MGX 8200 series WAN switch (SONET line cards)
Monitoring Examples
An operator monitors sonetApsConfigTable/sonetApsConfigEntry for apsActiveLine to confirm traffic is riding the expected working line, and watches apsSFBER/apsSDBER thresholds to catch early bit-error-rate degradation before a hard failure. If apsActiveLine unexpectedly switches to the protection line (apsProtectionSlot/apsProtectionLine) and apsWtr shows an active wait-to-restore timer, that signals a recent working-line fault that triggered automatic APS protection switching.
What Can Be Monitored
- active vs. protection line status
- signal-fail/signal-degrade BER thresholds
- APS architecture mode and enable state
- wait-to-restore timer
- working/protection slot and line assignment
This MIB depends on
Related MIBs
Imported Objects
From BASIS-MIB
| cwsonetObjects | OBJECT-IDENTITY |
From RFC-1212
| OBJECT-TYPE |
From RFC1155-SMI
| Counter | |
| Gauge |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| INT apsActiveLine | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.7 | INTEGER | read-only | This object indicates which line is currently active ob the trunk line. |
| INT apsArchMode | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.6 | INTEGER | read-write | This object is used to configure APS architecture mode on the working/protection line pairs. The architecture modes currently supported are 'dualCardonePlusOne' (for GR-253) and 'anexAOnePlusOne (for G.783 Annex A). |
| INT apsCardFailureCode | 1.3.6.1.4.1.351.110.4.6.1.6.2 | INTEGER | read-only | The Sonet APS card failure code apsProtectBCMissing = protection Back card missing apsProtectDCMissing = protection Daughter card missing apsWorkingBCMissing = Working Back card missing apsWorkingDCMissing = Working Daughter card missing apsWorkingCdMismatch = Working Card in mismatch/fail state apsProtectCdMismatch = protection card in mismatch/fail state |
| INT apsdirection | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.11 | INTEGER | read-write | This object is used to configure the switching direction which this APS line support. Unidirectional switch only one direction. Bidirectional switch in both ends of the line. |
| INT apsEnable | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.5 | INTEGER | read-write | This object is used to enable or disable APS feature on the working/protection line pairs. |
| INT apsK1K2Disable | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.13 | INTEGER | read-write | This object is used to enable or disable the K1/K2 inband interface on the protection line. |
| INT apsLineFailureCode | 1.3.6.1.4.1.351.110.4.6.1.6.3 | INTEGER | read-only | The Sonet APS line failure code |
| INT apsLineSwFailureCode | 1.3.6.1.4.1.351.110.4.6.1.6.5 | INTEGER | read-only | The Sonet APS line switch failure code |
| INT apsLineSwReason | 1.3.6.1.4.1.351.110.4.6.1.6.4 | INTEGER | read-only | The Sonet APS line switch reason code |
| INT apsProtectionLine | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.4 | INTEGER | read-write | This object is the line number of the working line OC-3 : sonetLineNum in a range 1..4 OC-12: sonetLineNum = 1 is the ONLY valid number |
| INT apsProtectionSlot | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.3 | INTEGER | read-write | This object is the chassis slot number of the protection line MGX 8x50 PXM: can only be slot 7 or 8. MGX 8x30 PXM: can only be slot 1 or 2. MGX 8x50 SRME: can only be slot 15,16,31 or 32 MGX 8x30 SRME: can only be slot 7 or 14 |
| INT apsRevertive | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.12 | INTEGER | read-write | This object is used to configure the APS revertive or nonrevertive option. Revertive allows the line to be switch back to working line after the Wait-To-restore interval has expired and the working line SF/SD has been cleared. |
| INT apsSDBER | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.9 | INTEGER | read-write | This object contains the Bit Error Rate threshold for Signal Degrade detection on the working line. If set to 5, it means SDBER rate = 10 ^^ -5. |
| INT apsSFBER | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.8 | INTEGER | read-write | This object contains the Bit Error Rate threshold for Signal Fault detection on the working line. |
| INT apsStandbyLineFailureCode | 1.3.6.1.4.1.351.110.4.6.1.6.6 | INTEGER | read-only | The Sonet APS standby line failure code |
| INT apsWorkingLine | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.2 | INTEGER | read-write | This object is the line number of the working line OC-3 : sonetLineNum in a range 1..4 OC-12: sonetLineNum = 1 is the ONLY valid number |
| INT apsWorkingSlot | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.1 | INTEGER | read-write | This object is the chassis slot number of the working line MGX 8x50 PXM: can only be slot 7 or 8. MGX 8x30 PXM: can only be slot 1 or 2. MGX 8x50 SRME: can only be slot 15,16,31 or 32 MGX 8x30 SRME: can only be slot 7 or 14 |
| INT apsWtr | 1.3.6.1.4.1.351.110.4.6.1.6.1.1.10 | INTEGER | read-write | This object contains interval (in minute) to wait before attempting to switch back to working line. Not applicable if the line configure in non-revertive mode. |
| INT cwSonetFarEndLineCurrentClrButton | 1.3.6.1.4.1.351.110.4.6.1.4.4.1.9 | INTEGER | read-write | Clears all the SONET Far End Line's Current 15min counters. |
| GAU cwSonetFarEndLineCurrentCVs | 1.3.6.1.4.1.351.110.4.6.1.4.4.1.6 | Gauge | read-only | The counter associated with the number of Far End Coding Violations reported via the far end block error (FEBE) count encountered by a SONET/SDH Medium/Section/Line interface in the current 15 minute interval. |
| cwSonetFarEndLineCurrentEntry | 1.3.6.1.4.1.351.110.4.6.1.4.4.1 | not-accessible | An entry in the SONET/SDH Far End Line Current table. | |
| GAU cwSonetFarEndLineCurrentESs | 1.3.6.1.4.1.351.110.4.6.1.4.4.1.4 | Gauge | read-only | The counter associated with the number of Far Far End Errored Seconds encountered by a SONET/SDH interface in the current 15 minute interval. |
| GAU cwSonetFarEndLineCurrentFCs | 1.3.6.1.4.1.351.110.4.6.1.4.4.1.7 | Gauge | read-only | The counter associated with the number of RFI failures occurred in the current 15 min. |
| GAU cwSonetFarEndLineCurrentSESs | 1.3.6.1.4.1.351.110.4.6.1.4.4.1.5 | Gauge | read-only | The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Medium/Section/Line interface in the current 15 minute interval. |
| cwSonetFarEndLineCurrentTable | 1.3.6.1.4.1.351.110.4.6.1.4.4 | not-accessible | The SONET/SDH Far End Line Current table. | |
| INT cwSonetFarEndLineCurrentTimeElapsed | 1.3.6.1.4.1.351.110.4.6.1.4.4.1.3 | INTEGER | read-only | The number of seconds, including partial seconds, that have elapsed since the beginning of the 15min error-measurement period. |
| GAU cwSonetFarEndLineCurrentUASs | 1.3.6.1.4.1.351.110.4.6.1.4.4.1.8 | Gauge | read-only | The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Medium/Section/Line interface in the current 15 minute interval. |
| INT cwSonetFarEndLineCurrentValidFlag | 1.3.6.1.4.1.351.110.4.6.1.4.4.1.2 | INTEGER | read-only | Indicates if the Far End current 15min bucket is valid or not. |
| GAU cwSonetFarEndLineIntervalCVs | 1.3.6.1.4.1.351.110.4.6.1.4.6.1.6 | Gauge | read-only | The counter associated with the number of Far End Coding Violations reported via the far end block error count encountered by a SONET/SDH Line interface in a particular 15-minute interval in the past 24 hours. |
| cwSonetFarEndLineIntervalEntry | 1.3.6.1.4.1.351.110.4.6.1.4.6.1 | not-accessible | An entry in the SONET/SDH Far End Line Interval table. | |
| GAU cwSonetFarEndLineIntervalESs | 1.3.6.1.4.1.351.110.4.6.1.4.6.1.4 | Gauge | read-only | The counter associated with the number of Far End Errored Seconds encountered by a SONET/SDH Line interface in a particular 15-minute interval in the past 24 hours. |
| GAU cwSonetFarEndLineIntervalFCs | 1.3.6.1.4.1.351.110.4.6.1.4.6.1.7 | Gauge | read-only | The counter associated with the number of RFI failures in a particular 15-minute interval in the past 24 hours. |
| INT cwSonetFarEndLineIntervalNumber | 1.3.6.1.4.1.351.110.4.6.1.4.6.1.2 | INTEGER | read-only | A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1. |
| GAU cwSonetFarEndLineIntervalSESs | 1.3.6.1.4.1.351.110.4.6.1.4.6.1.5 | Gauge | read-only | The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Line interface in a particular 15-minute interval in the past 24 hours. |
| cwSonetFarEndLineIntervalTable | 1.3.6.1.4.1.351.110.4.6.1.4.6 | not-accessible | The SONET/SDH Far End Line Interval table. | |
| GAU cwSonetFarEndLineIntervalUASs | 1.3.6.1.4.1.351.110.4.6.1.4.6.1.8 | Gauge | read-only | The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Line interface in a particular 15-minute interval in the past 24 hours. |
| INT cwSonetFarEndLineIntervalValidFlag | 1.3.6.1.4.1.351.110.4.6.1.4.6.1.3 | INTEGER | read-only | Indicates if the bucket specified by the interval is valid or not. |
| INT cwSonetFarEndPathCurrentClrButton | 1.3.6.1.4.1.351.110.4.6.1.5.4.1.9 | INTEGER | read-write | Clears all the Far End Path Current counters. |
| GAU cwSonetFarEndPathCurrentCVs | 1.3.6.1.4.1.351.110.4.6.1.5.4.1.6 | Gauge | read-only | The counter associated with the number of Far End Coding Violations reported via the far end block error (FEBE) count encountered by a SONET/SDH Path interface in the current 15 minute interval. |
| cwSonetFarEndPathCurrentEntry | 1.3.6.1.4.1.351.110.4.6.1.5.4.1 | not-accessible | An entry in the SONET/SDH Far End Path Current table. | |
| GAU cwSonetFarEndPathCurrentESs | 1.3.6.1.4.1.351.110.4.6.1.5.4.1.4 | Gauge | read-only | The counter associated with the number of Far Far End Errored Seconds encountered by a SONET/SDH interface in the current 15 minute interval. |
| GAU cwSonetFarEndPathCurrentFCs | 1.3.6.1.4.1.351.110.4.6.1.5.4.1.7 | Gauge | read-only | The counter associated with the number of RFIs in the current 15 minute interval. |
| GAU cwSonetFarEndPathCurrentSESs | 1.3.6.1.4.1.351.110.4.6.1.5.4.1.5 | Gauge | read-only | The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Path interface in the current 15 minute interval. |
| cwSonetFarEndPathCurrentTable | 1.3.6.1.4.1.351.110.4.6.1.5.4 | not-accessible | The SONET/SDH Far End Path Current table. | |
| INT cwSonetFarEndPathCurrentTimeElapsed | 1.3.6.1.4.1.351.110.4.6.1.5.4.1.3 | INTEGER | read-only | The number of seconds, including partial seconds, that have elapsed since the beginning of the 15min error-measurement period. |
| GAU cwSonetFarEndPathCurrentUASs | 1.3.6.1.4.1.351.110.4.6.1.5.4.1.8 | Gauge | read-only | The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Path interface in the current 15 minute interval. |
| INT cwSonetFarEndPathCurrentValidFlag | 1.3.6.1.4.1.351.110.4.6.1.5.4.1.2 | INTEGER | read-only | Indicates if the Far End current 15min bucket is valid or not. |
| GAU cwSonetFarEndPathIntervalCVs | 1.3.6.1.4.1.351.110.4.6.1.5.6.1.6 | Gauge | read-only | The counter associated with the number of Far End Coding Violations reported via the far end block error count encountered by a SONET/SDH Path interface in a particular 15-minute interval in the past 24 hours. |
| cwSonetFarEndPathIntervalEntry | 1.3.6.1.4.1.351.110.4.6.1.5.6.1 | not-accessible | An entry in the SONET/SDH Far End Path Interval table. | |
| GAU cwSonetFarEndPathIntervalESs | 1.3.6.1.4.1.351.110.4.6.1.5.6.1.4 | Gauge | read-only | The counter associated with the number of Far End Errored Seconds encountered by a SONET/SDH Path interface in a particular 15-minute interval in the past 24 hours. |
| GAU cwSonetFarEndPathIntervalFCs | 1.3.6.1.4.1.351.110.4.6.1.5.6.1.7 | Gauge | read-only | The counter associated with the number of RFIs in in a particular 15-minute interval in the past 24 hours. |
| INT cwSonetFarEndPathIntervalNumber | 1.3.6.1.4.1.351.110.4.6.1.5.6.1.2 | INTEGER | read-only | A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1. |
| GAU cwSonetFarEndPathIntervalSESs | 1.3.6.1.4.1.351.110.4.6.1.5.6.1.5 | Gauge | read-only | The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Path interface in a particular 15-minute interval in the past 24 hours. |
| cwSonetFarEndPathIntervalTable | 1.3.6.1.4.1.351.110.4.6.1.5.6 | not-accessible | The SONET/SDH Far End Path Interval table. | |
| GAU cwSonetFarEndPathIntervalUASs | 1.3.6.1.4.1.351.110.4.6.1.5.6.1.8 | Gauge | read-only | The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Path interface in a particular 15-minute interval in the past 24 hours. |
| INT cwSonetFarEndPathIntervalValidFlag | 1.3.6.1.4.1.351.110.4.6.1.5.6.1.3 | INTEGER | read-only | Indicates if the bucket specified by the interval is valid or not. |
| INT cwSonetFELineCurrentLineNum | 1.3.6.1.4.1.351.110.4.6.1.4.4.1.1 | INTEGER | read-only | line number. BNM has one line |
| INT cwSonetFELineIntervalLineNum | 1.3.6.1.4.1.351.110.4.6.1.4.6.1.1 | INTEGER | read-only | line number. BNM has one line |
| INT cwSonetFEPathCurrentLineNum | 1.3.6.1.4.1.351.110.4.6.1.5.4.1.1 | INTEGER | read-only | line number. BNM has one line |
| INT cwSonetFEPathIntervalLineNum | 1.3.6.1.4.1.351.110.4.6.1.5.6.1.1 | INTEGER | read-only | line number. BNM has one line |
| cwsonetLine | 1.3.6.1.4.1.351.110.4.6.1.4 | |||
| INT cwSonetLineCurrent15minTimeElapsed | 1.3.6.1.4.1.351.110.4.6.1.4.1.1.4 | INTEGER | read-only | The number of seconds, including partial seconds, that have elapsed since the beginning of the 15min error-measurement period. |
| INT cwSonetLineCurrentClrButton | 1.3.6.1.4.1.351.110.4.6.1.4.1.1.9 | INTEGER | read-write | Clears all the SONET Line's Current15min counters. |
| GAU cwSonetLineCurrentCVs | 1.3.6.1.4.1.351.110.4.6.1.4.1.1.7 | Gauge | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH Line in the current 15 minute interval. |
| cwSonetLineCurrentEntry | 1.3.6.1.4.1.351.110.4.6.1.4.1.1 | not-accessible | An entry in the SONET/SDH Line Current table. | |
| GAU cwSonetLineCurrentESs | 1.3.6.1.4.1.351.110.4.6.1.4.1.1.5 | Gauge | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Line in the current 15 minute interval. |
| INT cwSonetLineCurrentLineNum | 1.3.6.1.4.1.351.110.4.6.1.4.1.1.1 | INTEGER | read-only | line number. BNM has one line |
| GAU cwSonetLineCurrentSESs | 1.3.6.1.4.1.351.110.4.6.1.4.1.1.6 | Gauge | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute interval. |
| INT cwSonetLineCurrentStatus | 1.3.6.1.4.1.351.110.4.6.1.4.1.1.2 | INTEGER | read-only | This variable indicates the status of the sonet line layer. The cwSonetLineCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetLineNoDefect should be set if and only if no other flag is set. The various bit positions are: bit 1 = sonetLineNoDefect bit 2 = sonetLineRcvAIS bit 3 = sonetLineRcvRDI bit 4 = sonetLineXmtAis bit 5 = sonetLineXmtRdi |
| cwSonetLineCurrentTable | 1.3.6.1.4.1.351.110.4.6.1.4.1 | not-accessible | The SONET/SDH Line Current table. | |
| GAU cwSonetLineCurrentUASs | 1.3.6.1.4.1.351.110.4.6.1.4.1.1.8 | Gauge | read-only | The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH Line in the current 15 minute interval. |
| INT cwSonetLineCurrentValidFlag | 1.3.6.1.4.1.351.110.4.6.1.4.1.1.3 | INTEGER | read-only | Indicates if the current 15min bucket is valid or not. |
| GAU cwSonetLineIntervalCVs | 1.3.6.1.4.1.351.110.4.6.1.4.3.1.6 | Gauge | read-only | The counter associated with the number of Coding Violations (BIP-8*N) encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours. |
| cwSonetLineIntervalEntry | 1.3.6.1.4.1.351.110.4.6.1.4.3.1 | not-accessible | An entry in the SONET/SDH Line Interval table. | |
| GAU cwSonetLineIntervalESs | 1.3.6.1.4.1.351.110.4.6.1.4.3.1.4 | Gauge | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours. |
| GAU cwSonetLineIntervalFCs | 1.3.6.1.4.1.351.110.4.6.1.4.3.1.7 | Gauge | read-only | Number of times that line was in AIS alarm in the particular 15-minute interval in the past 24 hours. |
| INT cwSonetLineIntervalLineNum | 1.3.6.1.4.1.351.110.4.6.1.4.3.1.1 | INTEGER | read-only | line number. BNM has one line |
| INT cwSonetLineIntervalNumber | 1.3.6.1.4.1.351.110.4.6.1.4.3.1.2 | INTEGER | read-only | A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1. |
| GAU cwSonetLineIntervalSESs | 1.3.6.1.4.1.351.110.4.6.1.4.3.1.5 | Gauge | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours. |
| cwSonetLineIntervalTable | 1.3.6.1.4.1.351.110.4.6.1.4.3 | not-accessible | The SONET/SDH Line Interval table. | |
| GAU cwSonetLineIntervalUASs | 1.3.6.1.4.1.351.110.4.6.1.4.3.1.8 | Gauge | read-only | The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours. |
| INT cwSonetLineIntervalValidFlag | 1.3.6.1.4.1.351.110.4.6.1.4.3.1.3 | INTEGER | read-only | Indicates if the bucket specified by the interval is valid or not. |
| cwsonetMedium | 1.3.6.1.4.1.351.110.4.6.1.2 | |||
| STR cwSonetMediumCircuitIdentifier | 1.3.6.1.4.1.351.110.4.6.1.2.1.1.6 | DisplayString | read-only | This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting. |
| cwSonetMediumEntry | 1.3.6.1.4.1.351.110.4.6.1.2.1.1 | not-accessible | An entry in the SONET/SDH Medium table. | |
| INT cwSonetMediumLineCoding | 1.3.6.1.4.1.351.110.4.6.1.2.1.1.4 | INTEGER | read-only | This variable describes the line coding for this interface. The B3ZS and CMI are used for electrical SONET/SDH signals (STS-1 and STS-3). The Non-Return to Zero (NRZ) and the Return to Zero are used for optical SONET/SDH signals. |
| INT cwSonetMediumLineType | 1.3.6.1.4.1.351.110.4.6.1.2.1.1.5 | INTEGER | read-only | This variable describes the line type for this interface. The line types are Short and Long Range Single Mode fiber or Multi-Mode fiber interfaces, and coax and UTP for electrical interfaces. The value sonetOther should be used when the Line Type is not one of the listed values. |
| cwSonetMediumTable | 1.3.6.1.4.1.351.110.4.6.1.2.1 | not-accessible | Sonet medium table parameters | |
| INT cwSonetMediumTimeElapsed | 1.3.6.1.4.1.351.110.4.6.1.2.1.1.2 | INTEGER | read-only | The number of seconds, including partial seconds, that have elapsed since the beginning of the mandatory error-measurement period. |
| INT cwSonetMediumType | 1.3.6.1.4.1.351.110.4.6.1.2.1.1.1 | INTEGER | read-only | This variable identifies whether a SONET or a SDH signal is used across this interface. |
| INT cwSonetMediumValidIntervals | 1.3.6.1.4.1.351.110.4.6.1.2.1.1.3 | INTEGER | read-only | The number of previous intervals for which valid data has been stored. A SONET device must support at least n intervals. The minimum value of n is 4. The default of n is 32. The maximum value of n is 96. The value of this object will be n unless the device was brought online within the last (nx15) minutes, in which case the value will be the number of complete 15 minute intervals the device has been online. |
| cwsonetPath | 1.3.6.1.4.1.351.110.4.6.1.5 | |||
| INT cwSonetPathCurrentClrButton | 1.3.6.1.4.1.351.110.4.6.1.5.1.1.10 | INTEGER | read-write | Clears all the SONET Path's Current counters. |
| GAU cwSonetPathCurrentCVs | 1.3.6.1.4.1.351.110.4.6.1.5.1.1.7 | Gauge | read-only | The counter associated with the number of Coding Violations (BIP-8) encountered by a SONET/SDH Path in the current 15 minute interval. |
| cwSonetPathCurrentEntry | 1.3.6.1.4.1.351.110.4.6.1.5.1.1 | not-accessible | An entry in the SONET/SDH Path Current table. | |
| GAU cwSonetPathCurrentESs | 1.3.6.1.4.1.351.110.4.6.1.5.1.1.5 | Gauge | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Path in the current 15 minute interval. |
| GAU cwSonetPathCurrentFCs | 1.3.6.1.4.1.351.110.4.6.1.5.1.1.8 | Gauge | read-only | Number of times that Path was in AIS or LOP alarm in the current 15 minute interval. |
| INT cwSonetPathCurrentLineNum | 1.3.6.1.4.1.351.110.4.6.1.5.1.1.1 | INTEGER | read-only | line number. BNM has 1 line |
| GAU cwSonetPathCurrentSESs | 1.3.6.1.4.1.351.110.4.6.1.5.1.1.6 | Gauge | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Path in the current 15 minute interval. |
| INT cwSonetPathCurrentStatus | 1.3.6.1.4.1.351.110.4.6.1.5.1.1.2 | INTEGER | read-only | This variable indicates the status of the sonet path layer. The cwSonetPathCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetPathNoDefect should be set if and only if no other flag is set. The various bit positions are: bit 1 = sonetPathNoDefect bit 2 = sonetPathRcvLOP bit 3 = sonetPathRcvAIS bit 4 = sonetPathRcvRDI bit 5 = sonetPathUnequipted bit 6 = sonetPathSignalLabelMismatch bit 7 = sonetPathTraceFailure bit 8 = sonetPathXmtAis bit 9 = sonetPathXmtRdi bit 10 = sonetPathRcvLOCD |
| cwSonetPathCurrentTable | 1.3.6.1.4.1.351.110.4.6.1.5.1 | not-accessible | The SONET/SDH Path Current table. | |
| INT cwSonetPathCurrentTimeElapsed | 1.3.6.1.4.1.351.110.4.6.1.5.1.1.4 | INTEGER | read-only | The number of seconds, including partial seconds, that have elapsed since the beginning of the 15min error-measurement period. |
| GAU cwSonetPathCurrentUASs | 1.3.6.1.4.1.351.110.4.6.1.5.1.1.9 | Gauge | read-only | The counter associated with the number of Unavailable Seconds encountered by a Path in the current 15 minute, interval. |
| INT cwSonetPathCurrentValidFlag | 1.3.6.1.4.1.351.110.4.6.1.5.1.1.3 | INTEGER | read-only | Indicates if the current 15min bucket is valid or not. |
| GAU cwSonetPathIntervalCVs | 1.3.6.1.4.1.351.110.4.6.1.5.3.1.6 | Gauge | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH Path in a particular 15-minute interval in the past 24 hours. |
| cwSonetPathIntervalEntry | 1.3.6.1.4.1.351.110.4.6.1.5.3.1 | not-accessible | An entry in the SONET/SDH Path Interval table. | |
| GAU cwSonetPathIntervalESs | 1.3.6.1.4.1.351.110.4.6.1.5.3.1.4 | Gauge | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Path in a particular 15-minute interval in the past 24 hours. |
| GAU cwSonetPathIntervalFCs | 1.3.6.1.4.1.351.110.4.6.1.5.3.1.7 | Gauge | read-only | Number of times that Path was in AIS or LOP alarm in a particular 15-minute interval in the past 24 hours. |
| INT cwSonetPathIntervalLineNum | 1.3.6.1.4.1.351.110.4.6.1.5.3.1.1 | INTEGER | read-only | line number. BNM has one line |
| INT cwSonetPathIntervalNumber | 1.3.6.1.4.1.351.110.4.6.1.5.3.1.2 | INTEGER | read-only | A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1. |
| GAU cwSonetPathIntervalSESs | 1.3.6.1.4.1.351.110.4.6.1.5.3.1.5 | Gauge | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Path in a particular 15-minute interval in the past 24 hours. |
| cwSonetPathIntervalTable | 1.3.6.1.4.1.351.110.4.6.1.5.3 | not-accessible | The SONET/SDH Path Interval table. | |
| GAU cwSonetPathIntervalUASs | 1.3.6.1.4.1.351.110.4.6.1.5.3.1.8 | Gauge | read-only | The counter associated with the number of Unavailable Seconds encountered by a Path in a particular 15-minute interval in the past 24 hours. |
| INT cwSonetPathIntervalValidFlag | 1.3.6.1.4.1.351.110.4.6.1.5.3.1.3 | INTEGER | read-only | Indicates if the bucket specified by the interval is valid or not. |
| cwsonetSection | 1.3.6.1.4.1.351.110.4.6.1.3 | |||
| INT cwSonetSectionCurrent15minTimeElapsed | 1.3.6.1.4.1.351.110.4.6.1.3.1.1.4 | INTEGER | read-only | The number of seconds, including partial seconds, that have elapsed since the beginning of the 15min error-measurement period. |
| INT cwSonetSectionCurrentClrButton | 1.3.6.1.4.1.351.110.4.6.1.3.1.1.9 | INTEGER | read-write | Clears all the Section's Current15min counters. |
| CTR cwSonetSectionCurrentCVs | 1.3.6.1.4.1.351.110.4.6.1.3.1.1.8 | Counter | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH Section in the current 15 minute interval. |
| cwSonetSectionCurrentEntry | 1.3.6.1.4.1.351.110.4.6.1.3.1.1 | not-accessible | An entry in the SONET/SDH Section Current table. | |
| CTR cwSonetSectionCurrentESs | 1.3.6.1.4.1.351.110.4.6.1.3.1.1.5 | Counter | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Section in the current 15 minute interval. |
| INT cwSonetSectionCurrentLineNum | 1.3.6.1.4.1.351.110.4.6.1.3.1.1.1 | INTEGER | read-only | line number. There are Max 1 line Num |
| CTR cwSonetSectionCurrentSEFSs | 1.3.6.1.4.1.351.110.4.6.1.3.1.1.7 | Counter | read-only | The counter associated with the number of Severely Errored Framing Seconds encountered by a SONET/SDH Section in the current 15 minute interval. |
| CTR cwSonetSectionCurrentSESs | 1.3.6.1.4.1.351.110.4.6.1.3.1.1.6 | Counter | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Section in the current 15 minute interval. |
| INT cwSonetSectionCurrentStatus | 1.3.6.1.4.1.351.110.4.6.1.3.1.1.2 | INTEGER | read-only | This variable indicates the status of the sonet section layer. The cwSonetSectionCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetSectionNoDefect should be set if and only if no other flag is set. The various bit positions are: bit 1 = sonetSectionNoDefect bit 2 = sonetSectionLOS bit 3 = sonetSectionLOF |
| cwSonetSectionCurrentTable | 1.3.6.1.4.1.351.110.4.6.1.3.1 | not-accessible | The SONET/SDH Section Current table. | |
| INT cwSonetSectionCurrentValidFlag | 1.3.6.1.4.1.351.110.4.6.1.3.1.1.3 | INTEGER | read-only | Indicates if the current 15min bucket is valid or not. |
| CTR cwSonetSectionIntervalCVs | 1.3.6.1.4.1.351.110.4.6.1.3.3.1.7 | Counter | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours. |
| cwSonetSectionIntervalEntry | 1.3.6.1.4.1.351.110.4.6.1.3.3.1 | not-accessible | An entry in the SONET/SDH Section Interval table. | |
| CTR cwSonetSectionIntervalESs | 1.3.6.1.4.1.351.110.4.6.1.3.3.1.4 | Counter | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours. |
| INT cwSonetSectionIntervalLineNum | 1.3.6.1.4.1.351.110.4.6.1.3.3.1.1 | INTEGER | read-only | line number. BNM has one line |
| INT cwSonetSectionIntervalNumber | 1.3.6.1.4.1.351.110.4.6.1.3.3.1.2 | INTEGER | read-only | A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1. |
| CTR cwSonetSectionIntervalSEFss | 1.3.6.1.4.1.351.110.4.6.1.3.3.1.6 | Counter | read-only | The counter associated with the number of Severely Errored Framing Seconds encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours. |
| CTR cwSonetSectionIntervalSESs | 1.3.6.1.4.1.351.110.4.6.1.3.3.1.5 | Counter | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours. |
| cwSonetSectionIntervalTable | 1.3.6.1.4.1.351.110.4.6.1.3.3 | not-accessible | The SONET/SDH Section Interval table. | |
| INT cwSonetSectionIntervalValidFlag | 1.3.6.1.4.1.351.110.4.6.1.3.3.1.3 | INTEGER | read-only | Indicates if the bucket specified by the interval is valid or not. |
| INT lineCurrentDayLineNum | 1.3.6.1.4.1.351.110.4.6.1.4.2.1.1 | INTEGER | read-only | line number. BNM has 1 line |
| INT sectionAlarmLineNum | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.1 | INTEGER | read-only | line number. BNM has 1 line |
| INT sectionCounterLineNum | 1.3.6.1.4.1.351.110.4.6.1.3.5.1.1 | INTEGER | read-only | line number. There are Max 1 line on the BNM |
| sonetApsConfig | 1.3.6.1.4.1.351.110.4.6.1.6 | |||
| sonetApsConfigEntry | 1.3.6.1.4.1.351.110.4.6.1.6.1.1 | not-accessible | An entry in the Sonet APS table. Each Entry is index by the working Line number. | |
| sonetApsConfigTable | 1.3.6.1.4.1.351.110.4.6.1.6.1 | not-accessible | The Sonet APS config table | |
| sonetConfig | 1.3.6.1.4.1.351.110.4.6.1.1 | |||
| sonetConfigEntry | 1.3.6.1.4.1.351.110.4.6.1.1.1.1 | not-accessible | An entry in the SONET Configuration table. | |
| INT sonetConfigNumOfValidEntries | 1.3.6.1.4.1.351.110.4.6.1.1.2 | INTEGER | read-only | The number of SONET configuration entries (regardless of their current configuration) in the sonetConfigTable. |
| sonetConfigTable | 1.3.6.1.4.1.351.110.4.6.1.1.1 | not-accessible | The SONET Configuration table. There is one row for each SONET port in the BASIS system. The table size (number of rows) is given by the value of sonetLineNumOfValidEntries. | |
| INT sonetFarEndLineCurrentDayClrButton | 1.3.6.1.4.1.351.110.4.6.1.4.5.1.8 | INTEGER | read-write | Clears all the SONET Far End Line's Current Day counters. |
| GAU sonetFarEndLineCurrentDayCVs | 1.3.6.1.4.1.351.110.4.6.1.4.5.1.5 | Gauge | read-only | The counter associated with the number of Far End Coding Violations reported via the far end block error (FEBE) count encountered by a SONET/SDH Medium/Section/Line interface in the current day interval. |
| sonetFarEndLineCurrentDayEntry | 1.3.6.1.4.1.351.110.4.6.1.4.5.1 | not-accessible | An entry in the SONET/SDH Far End Line CurrentDay table. | |
| GAU sonetFarEndLineCurrentDayESs | 1.3.6.1.4.1.351.110.4.6.1.4.5.1.3 | Gauge | read-only | The counter associated with the number of Far Far End Errored Seconds encountered by a SONET/SDH interface in the current day interval. |
| GAU sonetFarEndLineCurrentDayFCs | 1.3.6.1.4.1.351.110.4.6.1.4.5.1.6 | Gauge | read-only | The counter associated with the number of RFI failures occurred in the current day interval. |
| GAU sonetFarEndLineCurrentDaySESs | 1.3.6.1.4.1.351.110.4.6.1.4.5.1.4 | Gauge | read-only | The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Medium/Section/Line interface in the current day interval. |
| sonetFarEndLineCurrentDayTable | 1.3.6.1.4.1.351.110.4.6.1.4.5 | not-accessible | The SONET/SDH Far End Line CurrentDay table. | |
| GAU sonetFarEndLineCurrentDayUASs | 1.3.6.1.4.1.351.110.4.6.1.4.5.1.7 | Gauge | read-only | The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Medium/Section/Line interface in the current day interval. |
| INT sonetFarEndLineCurrentDayValidFlag | 1.3.6.1.4.1.351.110.4.6.1.4.5.1.2 | INTEGER | read-only | Indicates if the Far End current day bucket is valid or not. |
| INT sonetFarEndPathCurrentDayClrButton | 1.3.6.1.4.1.351.110.4.6.1.5.5.1.8 | INTEGER | read-write | Clears all the Far End Path CurrentDay counters. |
| GAU sonetFarEndPathCurrentDayCVs | 1.3.6.1.4.1.351.110.4.6.1.5.5.1.5 | Gauge | read-only | The counter associated with the number of Far End Coding Violations reported via the far end block error (FEBE) count encountered by a SONET/SDH Path interface in the Current day interval. |
| sonetFarEndPathCurrentDayEntry | 1.3.6.1.4.1.351.110.4.6.1.5.5.1 | not-accessible | An entry in the SONET/SDH Far End Path CurrentDay table. | |
| GAU sonetFarEndPathCurrentDayESs | 1.3.6.1.4.1.351.110.4.6.1.5.5.1.3 | Gauge | read-only | The counter associated with the number of Far Far End Errored Seconds encountered by a SONET/SDH interface in the Current day interval. |
| GAU sonetFarEndPathCurrentDayFCs | 1.3.6.1.4.1.351.110.4.6.1.5.5.1.6 | Gauge | read-only | The counter associated with the number of RFIs in the Current day interval. |
| GAU sonetFarEndPathCurrentDaySESs | 1.3.6.1.4.1.351.110.4.6.1.5.5.1.4 | Gauge | read-only | The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Path interface in the Current day interval. |
| sonetFarEndPathCurrentDayTable | 1.3.6.1.4.1.351.110.4.6.1.5.5 | not-accessible | The SONET/SDH Far End Path CurrentDay table. | |
| GAU sonetFarEndPathCurrentDayUASs | 1.3.6.1.4.1.351.110.4.6.1.5.5.1.7 | Gauge | read-only | The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Path interface in the Current day interval. |
| INT sonetFarEndPathCurrentDayValidFlag | 1.3.6.1.4.1.351.110.4.6.1.5.5.1.2 | INTEGER | read-only | Indicates if the Far End current day bucket is valid or not. |
| INT sonetFELineCurrentDayLineNum | 1.3.6.1.4.1.351.110.4.6.1.4.5.1.1 | INTEGER | read-only | line number. BNM has one line |
| INT sonetFEPathCurrentDayLineNum | 1.3.6.1.4.1.351.110.4.6.1.5.5.1.1 | INTEGER | read-only | line number. BNM has one line |
| INT sonetFrameScrambling | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.6 | INTEGER | read-write | STS3c or STM-1 frame scrambling. Defaults to enable. |
| INT sonetHCSmasking | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.4 | INTEGER | read-write | HCS masking. Defaults to enable. |
| sonetLineAlarmEntry | 1.3.6.1.4.1.351.110.4.6.1.4.7.1 | not-accessible | An entry in the SONET/SDH Line Alarm table. | |
| INT sonetLineAlarmLineNum | 1.3.6.1.4.1.351.110.4.6.1.4.7.1.1 | INTEGER | read-only | line number. BNM has one line |
| sonetLineAlarmTable | 1.3.6.1.4.1.351.110.4.6.1.4.7 | not-accessible | The SONET/SDH Line Alarm table. | |
| GAU sonetLineCounterAISs | 1.3.6.1.4.1.351.110.4.6.1.4.8.1.2 | Gauge | read-only | The counter associated with the number of AISs encountered by a SONET/SDH. |
| INT sonetLineCounterClrButton | 1.3.6.1.4.1.351.110.4.6.1.4.8.1.4 | INTEGER | read-write | Clears all the Line's counters. |
| sonetLineCounterEntry | 1.3.6.1.4.1.351.110.4.6.1.4.8.1 | not-accessible | An entry in the SONET/SDH Line table. | |
| INT sonetLineCounterLineNum | 1.3.6.1.4.1.351.110.4.6.1.4.8.1.1 | INTEGER | read-only | line number. BNM has one line |
| GAU sonetLineCounterRFIs | 1.3.6.1.4.1.351.110.4.6.1.4.8.1.3 | Gauge | read-only | The counter associated with the number of RFIs encountered by a SONET/SDH Line. |
| sonetLineCounterTable | 1.3.6.1.4.1.351.110.4.6.1.4.8 | not-accessible | The SONET/SDH Line Counter table. | |
| INT sonetLineCurrent15minCVsThreshold | 1.3.6.1.4.1.351.110.4.6.1.4.7.1.7 | INTEGER | read-write | The default is set to 25. This threshold is the same for Far End and Near End. |
| INT sonetLineCurrent15minESsThreshold | 1.3.6.1.4.1.351.110.4.6.1.4.7.1.3 | INTEGER | read-write | The default is set to 20. This threshold is the same for Far End and Near End. |
| INT sonetLineCurrent15minSESsThreshold | 1.3.6.1.4.1.351.110.4.6.1.4.7.1.5 | INTEGER | read-write | The default is set to 3. This threshold is the same for Far End and Near End. |
| INT sonetLineCurrent15minUASsThreshold | 1.3.6.1.4.1.351.110.4.6.1.4.7.1.9 | INTEGER | read-write | The default is set to 10. This threshold is the same for Far End and Near End. |
| INT sonetLineCurrentDayClrButton | 1.3.6.1.4.1.351.110.4.6.1.4.2.1.8 | INTEGER | read-write | Clears all the SONET Line's CurrentDay counters. |
| GAU sonetLineCurrentDayCVs | 1.3.6.1.4.1.351.110.4.6.1.4.2.1.5 | Gauge | read-only | The counter associated with the number of Coding Violations (BIP-8*N for STS-N) encountered by a SONET/SDH Line in the current day interval. |
| INT sonetLineCurrentDayCVsThreshold | 1.3.6.1.4.1.351.110.4.6.1.4.7.1.8 | INTEGER | read-write | The default is set to 250. This threshold is the same for Far End and Near End. |
| sonetLineCurrentDayEntry | 1.3.6.1.4.1.351.110.4.6.1.4.2.1 | not-accessible | An entry in the SONET/SDH Line Current Day table. | |
| GAU sonetLineCurrentDayESs | 1.3.6.1.4.1.351.110.4.6.1.4.2.1.3 | Gauge | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Line in the current day interval. |
| INT sonetLineCurrentDayESsThreshold | 1.3.6.1.4.1.351.110.4.6.1.4.7.1.4 | INTEGER | read-write | The default is set to 200. This threshold is the same for Far End and Near End. |
| GAU sonetLineCurrentDayFCs | 1.3.6.1.4.1.351.110.4.6.1.4.2.1.6 | Gauge | read-only | Number of times that line was in AIS alarm in the current day interval. |
| GAU sonetLineCurrentDaySESs | 1.3.6.1.4.1.351.110.4.6.1.4.2.1.4 | Gauge | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current day interval. |
| INT sonetLineCurrentDaySESsThreshold | 1.3.6.1.4.1.351.110.4.6.1.4.7.1.6 | INTEGER | read-write | The default is set to 7. This threshold is the same for Far End and Near End. |
| sonetLineCurrentDayTable | 1.3.6.1.4.1.351.110.4.6.1.4.2 | not-accessible | The SONET/SDH Line Current Day table. | |
| GAU sonetLineCurrentDayUASs | 1.3.6.1.4.1.351.110.4.6.1.4.2.1.7 | Gauge | read-only | The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH Line in the current day interval. |
| INT sonetLineCurrentDayUASsThreshold | 1.3.6.1.4.1.351.110.4.6.1.4.7.1.10 | INTEGER | read-write | The default is set to 10. This threshold is the same for Far End and Near End. |
| INT sonetLineCurrentDayValidFlag | 1.3.6.1.4.1.351.110.4.6.1.4.2.1.2 | INTEGER | read-only | Indicates if the current day bucket is valid or not. |
| INT sonetLineEnable | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.7 | INTEGER | read-write | This variable indicates if the line is enabled or not defaults to disable |
| INT sonetLineLoopbackCommand | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.3 | INTEGER | read-write | This variable represents the loopback configuration of the SONET interface. The values mean: sonetNoLoop Not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as it's value. sonetRemoteLineLoop Near End loops back Remote data sonetLocalLineLoop Near End loops back Local data. |
| INT sonetLineNum | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.1 | INTEGER | read-only | This object is the identifier of a SONET Interface on a managed device. For MGX8850(For example PXM1 Module): OC-3 : sonetLineNum in a range 1..4 OC-12: sonetLineNum = 1 is the ONLY valid number For Other: sonetLineNum = 1 is the ONLY valid number |
| INT sonetLineStatAlarmStatus | 1.3.6.1.4.1.351.110.4.6.1.4.7.1.11 | INTEGER | read-only | This variable indicates the status of the interface. The sonetLineStatAlarmStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetLineStatAlarmNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sonetLineStatAlarmNoDefect 2 sonetLineCurrent15minESs 3 sonetLineCurrent15minSESs 4 sonetLineCurrent15minCVs 5 sonetLineCurrent15minUASs 6 sonetFarEndLineCurrent15minESs 7 sonetFarEndLineCurrent15minSESs 8 sonetFarEndLineCurrent15minCVs 9 sonetFarEndLineCurrent15minUASs 10 sonetLineCurrentDayESs 11 sonetLineCurrentDaySESs 12 sonetLineCurrentDayCVs 13 sonetLineCurrentDayUASs 14 sonetFarEndLineCurrentDayESs 15 sonetFarEndLineCurrentDaySESs 16 sonetFarEndLineCurrentDayCVs 17 sonetFarEndLineCurrentDayUASs |
| INT sonetLineStatisticalAlarmSeverity | 1.3.6.1.4.1.351.110.4.6.1.4.7.1.2 | INTEGER | read-write | When any statistical threshold is exceeded. |
| INT sonetLineType | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.2 | INTEGER | read-write | This variable indicates the cell framing. Defaults to Sts-3c |
| INT sonetLineXmtClkSrc | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.8 | INTEGER | read-write | This represents the type of transmit clock source. backplaneClk: clock source is from the controller card, transmitted via the backplane to the service module. recoverClk: clock is recovered from the received signal. localClk: clock is from a local oscillator on the card. Default is backplaneClk. |
| sonetPathAlarmEntry | 1.3.6.1.4.1.351.110.4.6.1.5.7.1 | not-accessible | An entry in the SONET/SDH Path Alarm table. | |
| INT sonetPathAlarmLineNum | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.1 | INTEGER | read-only | line number. BNM has one line |
| sonetPathAlarmTable | 1.3.6.1.4.1.351.110.4.6.1.5.7 | not-accessible | The SONET/SDH Path Alarm table. | |
| GAU sonetPathCounterAISs | 1.3.6.1.4.1.351.110.4.6.1.5.8.1.2 | Gauge | read-only | The counter associated with the number of AISs encountered by a SONET/SDH. |
| INT sonetPathCounterClrButton | 1.3.6.1.4.1.351.110.4.6.1.5.8.1.4 | INTEGER | read-write | Clears all the Path's counters. |
| sonetPathCounterEntry | 1.3.6.1.4.1.351.110.4.6.1.5.8.1 | not-accessible | An entry in the SONET/SDH Path table. | |
| INT sonetPathCounterLineNum | 1.3.6.1.4.1.351.110.4.6.1.5.8.1.1 | INTEGER | read-only | line number. BNM has one line |
| GAU sonetPathCounterRFIs | 1.3.6.1.4.1.351.110.4.6.1.5.8.1.3 | Gauge | read-only | The counter associated with the number of RFIs encountered by a SONET/SDH Path. |
| sonetPathCounterTable | 1.3.6.1.4.1.351.110.4.6.1.5.8 | not-accessible | The SONET/SDH Path Counter table. | |
| INT sonetPathCurrent15minCVsThreshold | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.7 | INTEGER | read-write | The default is set to 25. This threshold is the same for Far End and Near End. |
| INT sonetPathCurrent15minESsThreshold | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.3 | INTEGER | read-write | The default is set to 20. This threshold is the same for Far End and Near End. |
| INT sonetPathCurrent15minSESsThreshold | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.5 | INTEGER | read-write | The default is set to 3. This threshold is the same for Far End and Near End. |
| INT sonetPathCurrent15minUASsThreshold | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.9 | INTEGER | read-write | The default is set to 10. This threshold is the same for Far End and Near End. |
| INT sonetPathCurrentDayClrButton | 1.3.6.1.4.1.351.110.4.6.1.5.2.1.8 | INTEGER | read-write | Clears all the SONET Path's CurrentDay counters. |
| GAU sonetPathCurrentDayCVs | 1.3.6.1.4.1.351.110.4.6.1.5.2.1.5 | Gauge | read-only | The counter associated with the number of Coding Violations (BIP-8) encountered by a SONET/SDH Path in the Current day interval. |
| INT sonetPathCurrentDayCVsThreshold | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.8 | INTEGER | read-write | The default is set to 250. This threshold is the same for Far End and Near End. |
| sonetPathCurrentDayEntry | 1.3.6.1.4.1.351.110.4.6.1.5.2.1 | not-accessible | An entry in the SONET/SDH Path CurrentDay table. | |
| GAU sonetPathCurrentDayESs | 1.3.6.1.4.1.351.110.4.6.1.5.2.1.3 | Gauge | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Path in the Current day interval. |
| INT sonetPathCurrentDayESsThreshold | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.4 | INTEGER | read-write | The default is set to 200. This threshold is the same for Far End and Near End. |
| GAU sonetPathCurrentDayFCs | 1.3.6.1.4.1.351.110.4.6.1.5.2.1.6 | Gauge | read-only | Number of times that Path was in AIS or LOP alarm in the Current interval. |
| INT sonetPathCurrentDayLineNum | 1.3.6.1.4.1.351.110.4.6.1.5.2.1.1 | INTEGER | read-only | line number. BNM has one line |
| GAU sonetPathCurrentDaySESs | 1.3.6.1.4.1.351.110.4.6.1.5.2.1.4 | Gauge | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Path in the Current day interval. |
| INT sonetPathCurrentDaySESsThreshold | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.6 | INTEGER | read-write | The default is set to 7. This threshold is the same for Far End and Near End. |
| sonetPathCurrentDayTable | 1.3.6.1.4.1.351.110.4.6.1.5.2 | not-accessible | The SONET/SDH Path CurrentDay table. | |
| GAU sonetPathCurrentDayUASs | 1.3.6.1.4.1.351.110.4.6.1.5.2.1.7 | Gauge | read-only | The counter associated with the number of Unavailable Seconds encountered by a Path in the Current day, interval. |
| INT sonetPathCurrentDayUASsThreshold | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.10 | INTEGER | read-write | The default is set to 10. This threshold is the same for Far End and Near End. |
| INT sonetPathCurrentDayValidFlag | 1.3.6.1.4.1.351.110.4.6.1.5.2.1.2 | INTEGER | read-only | Indicates if the current day bucket is valid or not. |
| INT sonetPathStatAlarmStatus | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.15 | INTEGER | read-only | This variable indicates the status of the interface. The sonetPathStatAlarmStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetPathStatAlarmNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sonetPathStatAlarmNoDefect 2 sonetPathCurrent15minESs 3 sonetPathCurrent15minSESs 4 sonetPathCurrent15minCVs 5 sonetPathCurrent15minUASs 6 sonetFarEndPathCurrent15minESs 7 sonetFarEndPathCurrent15minSESs 8 sonetFarEndPathCurrent15minCVs 9 sonetFarEndPathCurrent15minUASs 10 sonetPathCurrentDayESs 11 sonetPathCurrentDaySESs 12 sonetPathCurrentDayCVs 13 sonetPathCurrentDayUASs 14 sonetFarEndPathCurrentDayESs 15 sonetFarEndPathCurrentDaySESs 16 sonetFarEndPathCurrentDayCVs 17 sonetFarEndPathCurrentDayUASs |
| INT sonetPathStatisticalAlarmSeverity | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.2 | INTEGER | read-write | When any statistical threshold is exceeded. |
| OCT sonetPathTraceReceived | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.14 | OCTET STRING | read-write | Sonet Path Trace Received. 64-bytes String. The write option is for debugging only. |
| INT sonetPathTraceSelection | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.11 | INTEGER | read-write | Sonet Path Trace Selection. |
| OCT sonetPathTraceToExpect | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.13 | OCTET STRING | read-write | Sonet Path Trace To Expect. 64-bytes String. If 16 byte trace is selected, FW will only use bytes 0-15 of the string. |
| OCT sonetPathTraceToTransmit | 1.3.6.1.4.1.351.110.4.6.1.5.7.1.12 | OCTET STRING | read-write | Sonet Path Trace To Transmit. 64-bytes String. If 16 byte trace is selected, FW will only use bytes 0-15 of the string. |
| INT sonetPayloadScrambling | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.5 | INTEGER | read-write | STS3c or STM-1 payload scrambling. Defaults to enable. |
| INT sonetRDIPType | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.10 | INTEGER | read-write | This variable represents the type of RDI-P sent by this NE to remote NE. onebit: use 1 bit RDI-P. Compatible with older equipment. threebit: use 3 bit, enhanced RDI-P. Defaults to onebit. |
| INT sonetRDIVType | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.9 | INTEGER | read-write | This variable represents the type of RDI-V sent by this NE to remote NE. onebit: use 1 bit RDI-V. Compatible with older equipment. threebit: use 3 bit, enhanced RDI-V. Defaults to onebit. |
| sonetSectionAlarmEntry | 1.3.6.1.4.1.351.110.4.6.1.3.4.1 | not-accessible | An entry in the SONET/SDH Section Alarm table. | |
| sonetSectionAlarmTable | 1.3.6.1.4.1.351.110.4.6.1.3.4 | not-accessible | The SONET/SDH Section Alarm table. | |
| INT sonetSectionCounterClrButton | 1.3.6.1.4.1.351.110.4.6.1.3.5.1.4 | INTEGER | read-write | Clears all the Section's counters. |
| sonetSectionCounterEntry | 1.3.6.1.4.1.351.110.4.6.1.3.5.1 | not-accessible | An entry in the SONET/SDH Section table. | |
| GAU sonetSectionCounterLOFs | 1.3.6.1.4.1.351.110.4.6.1.3.5.1.3 | Gauge | read-only | The counter associated with the number of LOFs encountered by a SONET/SDH Section. |
| GAU sonetSectionCounterLOSs | 1.3.6.1.4.1.351.110.4.6.1.3.5.1.2 | Gauge | read-only | The counter associated with the number of LOSs encountered by a SONET/SDH. |
| sonetSectionCounterTable | 1.3.6.1.4.1.351.110.4.6.1.3.5 | not-accessible | The SONET/SDH Section Counter table. | |
| INT sonetSectionCurrent15minCVsThreshold | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.9 | INTEGER | read-write | The default is set to 25. |
| INT sonetSectionCurrent15minESsThreshold | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.3 | INTEGER | read-write | The default is set to 20. |
| INT sonetSectionCurrent15minSEFSsThreshold | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.7 | INTEGER | read-write | The default is set to 3. |
| INT sonetSectionCurrent15minSESsThreshold | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.5 | INTEGER | read-write | The default is set to 3. |
| INT sonetSectionCurrentDayClrButton | 1.3.6.1.4.1.351.110.4.6.1.3.2.1.7 | INTEGER | read-write | Clears all the Section's Current Day counters. |
| CTR sonetSectionCurrentDayCVs | 1.3.6.1.4.1.351.110.4.6.1.3.2.1.6 | Counter | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH Section in the CurrentDay one day interval. |
| INT sonetSectionCurrentDayCVsThreshold | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.10 | INTEGER | read-write | The default is set to 250. |
| sonetSectionCurrentDayEntry | 1.3.6.1.4.1.351.110.4.6.1.3.2.1 | not-accessible | An entry in the SONET/SDH Section CurrentDay table. | |
| CTR sonetSectionCurrentDayESs | 1.3.6.1.4.1.351.110.4.6.1.3.2.1.3 | Counter | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Section in the CurrentDay one day interval. |
| INT sonetSectionCurrentDayESsThreshold | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.4 | INTEGER | read-write | The default is set to 200. |
| INT sonetSectionCurrentDayLineNum | 1.3.6.1.4.1.351.110.4.6.1.3.2.1.1 | INTEGER | read-only | line number. BNM has one line |
| CTR sonetSectionCurrentDaySEFSs | 1.3.6.1.4.1.351.110.4.6.1.3.2.1.5 | Counter | read-only | The counter associated with the number of Severely Errored Framing Seconds encountered by a SONET/SDH Section in the CurrentDay one day interval. |
| INT sonetSectionCurrentDaySEFSsThreshold | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.8 | INTEGER | read-write | The default is set to 7. |
| CTR sonetSectionCurrentDaySESs | 1.3.6.1.4.1.351.110.4.6.1.3.2.1.4 | Counter | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Section in the CurrentDay minute interval. |
| INT sonetSectionCurrentDaySESsThreshold | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.6 | INTEGER | read-write | The default is set to 7. |
| sonetSectionCurrentDayTable | 1.3.6.1.4.1.351.110.4.6.1.3.2 | not-accessible | The SONET/SDH Section CurrentDay table. | |
| INT sonetSectionCurrentDayValidFlag | 1.3.6.1.4.1.351.110.4.6.1.3.2.1.2 | INTEGER | read-only | Indicates if the current day bucket is valid or not. |
| INT sonetSectionStatAlarmStatus | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.15 | INTEGER | read-write | This variable indicates the status of the interface. The sonetSectionStatAlarmStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetLineStatAlarmNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sonetSectionStatAlarmNoDefect 2 sonetSectionCurrent15minESs 3 sonetSectionCurrent15minSESs 4 sonetSectionCurrent15minSEFSs 5 sonetSectionCurrent15minCVs 6 sonetSectionCurrentDayESs 7 sonetSectionCurrentDaySESs 8 sonetSectionCurrentDaySEFSs 9 sonetSectionCurrentDayCVs |
| INT sonetSectionStatisticalAlarmSeverity | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.2 | INTEGER | read-write | When any statistical threshold is exceeded. |
| OCT sonetSectionTraceReceived | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.14 | OCTET STRING | read-write | Sonet Section Trace Received. 16-64 bytes String. The write option is for debugging only. |
| INT sonetSectionTraceSelection | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.11 | INTEGER | read-write | Sonet Section Trace Selection. |
| OCT sonetSectionTraceToExpect | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.13 | OCTET STRING | read-write | Sonet Section Trace To Expect. 16-64 bytes String. If 16 byte trace is selected, FW will only use bytes 0-15 of the string. |
| OCT sonetSectionTraceToTransmit | 1.3.6.1.4.1.351.110.4.6.1.3.4.1.12 | OCTET STRING | read-write | Sonet Section Trace To Transmit. 16-64 bytes String. If 16 byte trace is selected, FW will only use bytes 0-15 of the string. |
| INT sonetSignallingTransportMode | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.14 | INTEGER | read-write | The mode used to transport DS0 signalling information for T1 byte-sync mapping. notApplicable: if byte-sync mapping is not used. signallingTransferMode: the robbed bit signalling is transferred into the S bits of the VT header and framing bit is discarded. clearMode: only the framing bit is transferred to VT header. The signalling bits are left intact in the VT payload. Default is signallingTransferMode if sonetTributaryMappingType is set to byteSynchronous, else the default is notApplicable. |
| INT sonetTributaryFramingFormat | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.13 | INTEGER | read-write | Type of vt framing format. Is applicable only in byte-sync mapping mode for T1 tributaries. notApplicable: if VT mapping is not byte-sync. sf: superframe format. esf: extended superframe format. Default is esf if sonetTributaryMappingType is set to byteSynchronous, else the default is notApplicable. |
| INT sonetTributaryGroupingType | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.15 | INTEGER | read-write | This variable indicates the method used to group VCs into an STM-1 signal. Applicable only to SDH. notApplicable: for sonet interfaces. au3Grouping: STM-1 <- AU-3 <- TUG-2 <- TU-12 <- VC12 or STM-1 <- AU-3 <- TUG-2 <- TU-11 <- VC11. au4Grouping: STM-1 <- AU-4 <- TUG-3 <- TUG-2 <- TU-12 <- VC12 or STM-1 <- AU-4 <- TUG-3 <- TUG-2 <- TU-11 <- VC11. Defaults to au3Grouping for SDH interfaces and notApplicable for Sonet interfaces. |
| INT sonetTributaryMappingType | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.12 | INTEGER | read-write | Type of VT/VC mapping. asynchronous: In this mode, the channel structure of the DS1/E1 is neither visible nor preserved. byteSynchronous: In this mode, the DS0 channels inside the VC/VT can be found and extracted. Default is asynchronous. |
| INT sonetTributaryType | 1.3.6.1.4.1.351.110.4.6.1.1.1.1.11 | INTEGER | read-write | Type of tributary carried within the Sonet/Sdh signal. vt15vc11: carries T1 signals (VT15 or VC11) vt2vc12: carries E1 signals (VT2 or VC12) Default is vt15vc11 for Sonet interfaces and vt2vc12 for SDH interfaces. |
RFC description
Cisco vendor-private MIB for MGX8200 series multiservice switches; manages SONET/SDH interface configuration, alarms, and performance monitoring.
Start monitoring Cisco WAN switches with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.