GESINGLEUPS-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GESINGLEUPS-MIB

Organization: GE Digital Energy

Last Updated: 2010-07-05

Category: Domain: Power/UPS, Hardware and Environment, Vendor: GE

Description: GE Digital Energy MIB for single UPS system monitoring covering battery, input/output power, and alarm status.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is GESINGLEUPS-MIB?

GESINGLEUPS-MIB is a GE Digital Energy proprietary MIB (enterprise OID 818), a differently-named but functionally equivalent counterpart to GE-SINGLEUPS, for single-unit uninterruptible power supplies. Its objects mirror GE-SINGLEUPS's: a bitmask of discovered UPS units, request/reply polling objects, and generic identity fields (manufacturer, model, software versions, name, attached devices, serial number). As a hardware-status/inventory MIB it lets an administrator confirm UPS identity and firmware version. It is deployed on GE Digital Energy single-unit UPS systems. Engineers can download the GESINGLEUPS-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in GESINGLEUPS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • GE Digital Energy single-unit UPS systems

Monitoring Examples

An administrator reads upsIdentModelgen and upsIdentUPSSerialNumbergen to confirm the exact UPS model and unit before cross-referencing a vendor service bulletin against a fleet of GE UPS units.

What Can Be Monitored

  • UPS identity (manufacturer/model/serial/firmware)
Imported Objects

From SNMPv2-SMI

Counter32
Gauge32
Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-IDENTITY
OBJECT-TYPE
Unsigned32
enterprises

From SNMPv2-TC

AutonomousType
DisplayString
TEXTUAL-CONVENTION
TestAndIncr
TimeInterval
TimeStamp

How to Use in IPNetwork Monitor

Example using upsInputLineBadsgen OID:

Select a GE Digital Energy single-unit UPS system as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type upsInputLineBadsgen into the Find box to locate it in the OID tree, then select it and click OK. It reports a count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Monitors power supply and environmental status for GE/Eaton single-phase uninterruptible power supplies (UPS) including battery and load statistics.

Start monitoring GE Digital Energy single-unit UPS system with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download GESINGLEUPS-MIB