All MIBs › BDFB-MIB
Organization: Emerson Energy Systems North America (ESNA)
Last Updated: 2011-03-02
Category: Hardware and Environment
Description: Manages battery distribution fuse bay (BDFB) DC power distribution, monitoring breaker states and current draw.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is BDFB-MIB?
BDFB-MIB is a vendor-specific MIB from Emerson Energy Systems North America (ESNA) for its mini-BDFB (Battery Distribution Fuse Bay) DC power distribution equipment, used to distribute battery-backed DC power to network and telecom gear. It exposes hardware status data for the power distribution unit itself: circuit breaker/fuse states and current draw per branch circuit or feed. This MIB is squarely a hardware-health monitoring tool — breaker open/closed state and per-circuit current load are the key indicators of an over-current condition or a tripped fuse — rather than a software or performance-counter MIB. As an ESNA proprietary module it has no dependency on other MIBs beyond standard SNMPv2-SMI conventions. It's typically deployed in telecom central offices and data centers where DC-powered fuse bays distribute battery backup power to racks of dependent equipment. Engineers can download the BDFB-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in BDFB-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Emerson/ESNA mini-BDFB DC power distribution unit
- telecom DC power plant equipment
Monitoring Examples
No sample object or table names were retrievable for this MIB, so a concrete polling example can't be grounded in real identifiers. In general, a BDFB device of this kind would be polled for per-breaker current draw and breaker state, which an operator would use to catch an over-current condition or a tripped fuse before it causes loss of DC power to dependent equipment.
What Can Be Monitored
- breaker/fuse state (open/closed)
- current draw per circuit/feed
Imported Objects
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| enterprises | |
| mib-2 |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| TEXTUAL-CONVENTION |
How to Use in IPNetwork Monitor
Example using bdfbTotalBusCurrent OID:
OIDs
RFC description
Emerson BDFB power distribution monitoring including bus voltage, current, relay status, and alarm notifications.
Start monitoring Emerson/ESNA mini-BDFB DC power distribution units with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.