All MIBs › CPQIDE-MIB
Category: Hardware and Environment, Vendor: HP/HPE
Description: Monitors Compaq/HP IDE/ATA disk drive status and failure prediction on ProLiant servers.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CPQIDE-MIB?
CPQIDE-MIB is a Compaq/HP MIB providing management objects for IDE/ATA hard disk drives installed in ProLiant servers, focused on drive identification and failure-prediction (SMART-style) status. It exposes per-drive inventory data (model, firmware, capacity) and drive health/failure-prediction status objects consistent with other Compaq/HP disk MIBs of its era. Its central monitoring purpose is hardware health - detecting a disk that SMART/failure-prediction logic flags as degraded or at risk of failure before it actually fails - making it directly relevant to proactive disk maintenance on ProLiant servers. It likely parallels or depends on Compaq's broader server hardware MIB family (e.g., disk-array-style MIBs) sharing similar object conventions for drive status. It is typically deployed on legacy HP ProLiant servers using IDE/ATA disks, monitored by HP Insight Manager or a general SNMP monitoring system for early disk-failure warning. Engineers can download the CPQIDE-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in CPQIDE-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- HP/Compaq ProLiant server (IDE/ATA disk drives)
Monitoring Examples
No sample object names were supplied for this MIB, so specific OIDs cannot be cited here. Given its stated purpose, an administrator would be expected to poll a per-drive failure-prediction/status object to catch a disk reporting an imminent-failure condition before data loss occurs, similar to how Compaq's other physical-drive MIBs expose SMART-style status. This is a general characterization rather than a citation of confirmed object names.
What Can Be Monitored
- disk drive identification
- disk failure-prediction (SMART) status
This MIB depends on
Related MIBs
Imported Objects
From CPQHOST-MIB
| compaq | OBJECT-IDENTITY |
| cpqHoTrapFlags | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| Gauge | |
| enterprises |
From RFC1213-MIB
| DisplayString | |
| sysName |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| cpqIde | 1.3.6.1.4.1.232.14 | |||
| cpqIdeAtaDisk | 1.3.6.1.4.1.232.14.2.4 | |||
| INT cpqIdeAtaDiskCapacity | 1.3.6.1.4.1.232.14.2.4.1.1.8 | INTEGER | read-only | ATA Disk Capacity. This is the capacity of the ATA disk in megabytes. |
| INT cpqIdeAtaDiskChannel | 1.3.6.1.4.1.232.14.2.4.1.1.11 | INTEGER | read-only | ATA Disk Channel. other(1) The agent cannot determine the channel to which the ATA disk is attached. channel0(2) The ATA disk is attached to the primary channel. channel1(3) The ATA disk is attached to the secondary channel. serial(4) The disk is attached to the serial interface and channel no longer applies. |
| INT cpqIdeAtaDiskCondition | 1.3.6.1.4.1.232.14.2.4.1.1.7 | INTEGER | read-only | ATA Disk Condition. This is the condition of the ATA disk. |
| INT cpqIdeAtaDiskControllerIndex | 1.3.6.1.4.1.232.14.2.4.1.1.1 | INTEGER | read-only | An index that uniquely identifies each controller. |
| cpqIdeAtaDiskEntry | 1.3.6.1.4.1.232.14.2.4.1.1 | not-accessible | IDE ATA Disk Table Entry. | |
| STR cpqIdeAtaDiskFwRev | 1.3.6.1.4.1.232.14.2.4.1.1.4 | DisplayString | read-only | ATA Disk Firmware Revision. The is the firmware revision of the ATA disk. |
| INT cpqIdeAtaDiskIndex | 1.3.6.1.4.1.232.14.2.4.1.1.2 | INTEGER | read-only | An index that uniquely identifies each disk. |
| INT cpqIdeAtaDiskIsSpare | 1.3.6.1.4.1.232.14.2.4.1.1.14 | INTEGER | read-only | ATA Disk Spare? other(1) The agent cannot determine if the ATA disk is a spare. true(2) The ATA disk is a spare disk. false(3) The ATA disk is not a spare disk. |
| INT cpqIdeAtaDiskLogicalDriveMember | 1.3.6.1.4.1.232.14.2.4.1.1.13 | INTEGER | read-only | Logical Drive Membership? other(1) The agent cannot determine if the ATA disk is part of a logical drive. true(2) The ATA disk is part of a logical drive. false(3) The ATA disk is not part of a logical drive. |
| STR cpqIdeAtaDiskModel | 1.3.6.1.4.1.232.14.2.4.1.1.3 | DisplayString | read-only | ATA Disk Model. The is the model name of the ATA disk. |
| INT cpqIdeAtaDiskNumber | 1.3.6.1.4.1.232.14.2.4.1.1.12 | INTEGER | read-only | ATA Disk Number. other(1) The agent cannot determine the number of the ATA disk. device0(2) The ATA disk is device 0 (master). device1(3) The ATA disk is device 1 (slave). sataDevice0(4) The SATA disk is device 0. sataDevice1(5) The SATA disk is device 1. sataDevice2(6) The SATA disk is device 2. sataDevice3(7) The SATA disk is device 3. sataDevice4(8) The SATA disk is device 4. sataDevice5(9) The SATA disk is device 5. sataDevice6(10) The SATA disk is device 6. sataDevice7(11) The SATA disk is device 7. bay1(21) The disk is in bay 1. bay2(22) The disk is in bay 2. bay3(23) The disk is in bay 3. bay4(24) The disk is in bay 4. bay5(25) The disk is in bay 5. bay6(26) The disk is in bay 6. bay7(27) The disk is in bay 7. bay8(28) The disk is in bay 8. |
| STR cpqIdeAtaDiskOsName | 1.3.6.1.4.1.232.14.2.4.1.1.15 | DisplayString | read-only | ATA Disk OS Name. The OS name for this ATA disk. This field will be a null (size 0) string if the agent does not support OS name or if the ATA disk is part of a logical drive. |
| INT cpqIdeAtaDiskSataVersion | 1.3.6.1.4.1.232.14.2.4.1.1.17 | INTEGER | read-only | Physical Drive SATA Version. The following values are defined: other(1) The agent is unable to determine the SATA version for this disk or it is not a SATA disk. sataOne(2) The disk is SATA version one. sataTwo(3) The disk is SATA version two. |
| STR cpqIdeAtaDiskSerialNumber | 1.3.6.1.4.1.232.14.2.4.1.1.5 | DisplayString | read-only | ATA Disk Serial Number. The is the serial number of the ATA disk. |
| INT cpqIdeAtaDiskSmartEnabled | 1.3.6.1.4.1.232.14.2.4.1.1.9 | INTEGER | read-only | ATA Disk S.M.A.R.T Enabled? other(1) The agent cannot determine the state of S.M.A.R.T. monitoring on this ATA disk. true(2) The ATA disk has S.M.A.R.T motitoring enabled. false(3) The ATA disk does not have S.M.A.R.T motitoring enabled. |
| INT cpqIdeAtaDiskStatus | 1.3.6.1.4.1.232.14.2.4.1.1.6 | INTEGER | read-only | ATA Disk Status. This is the status of the ATA disk. |
| NTF cpqIdeAtaDiskStatusChange | 1.3.6.1.4.1.232.0.14004 | ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If the physical drive status is smartError(3) or failed(4), replace the drive. | ||
| cpqIdeAtaDiskTable | 1.3.6.1.4.1.232.14.2.4.1 | not-accessible | IDE ATA Disk Table. | |
| INT cpqIdeAtaDiskTransferMode | 1.3.6.1.4.1.232.14.2.4.1.1.10 | INTEGER | read-only | ATA Disk Transfer Mode. other(1) The agent cannot determine the transfer mode on this ATA disk. pioMode0(2) The ATA disk is using PIO mode 0. pioMode1(3) The ATA disk is using PIO mode 1. pioMode2(4) The ATA disk is using PIO mode 2. pioMode3(5) The ATA disk is using PIO mode 3. pioMode4(6) The ATA disk is using PIO mode 4. dmaMode0(7) The ATA disk is using DMA mode 0. dmaMode1(8) The ATA disk is using DMA mode 1. dmaMode2(9) The ATA disk is using DMA mode 2. ultraDmaMode0(10) The ATA disk is using Ultra DMA mode 0. ultraDmaMode1(11) The ATA disk is using Ultra DMA mode 1. ultraDmaMode2(12) The ATA disk is using Ultra DMA mode 2. ultraDmaMode3(13) The ATA disk is using Ultra DMA mode 3. ultraDmaMode4(14) The ATA disk is using Ultra DMA mode 4. ultraDmaMode5(15) The ATA disk is using Ultra DMA mode 5. |
| INT cpqIdeAtaDiskType | 1.3.6.1.4.1.232.14.2.4.1.1.16 | INTEGER | read-only | ATA Disk Type other(1) The agent cannot determine the disk type. ata(2) The disk type is parallel ATA. sata(3) The disk type is Serial ATA. |
| cpqIdeAtapiDevice | 1.3.6.1.4.1.232.14.2.5 | |||
| INT cpqIdeAtapiDeviceChannel | 1.3.6.1.4.1.232.14.2.5.1.1.7 | INTEGER | read-only | ATAPI Device Channel. other(1) The agent cannot determine the channel to which the ATAPI device is attached. channel0(2) The ATAPI device is attached to the primary channel. channel1(3) The ATAPI device is attached to the secondary channel. |
| INT cpqIdeAtapiDeviceControllerIndex | 1.3.6.1.4.1.232.14.2.5.1.1.1 | INTEGER | read-only | An index that uniquely identifies each controller. |
| cpqIdeAtapiDeviceEntry | 1.3.6.1.4.1.232.14.2.5.1.1 | not-accessible | IDE ATAPI Device Table Entry. | |
| STR cpqIdeAtapiDeviceFwRev | 1.3.6.1.4.1.232.14.2.5.1.1.4 | DisplayString | read-only | ATAPI Device Firmware Revision. The is the firmware revision of the ATAPI device. |
| INT cpqIdeAtapiDeviceIndex | 1.3.6.1.4.1.232.14.2.5.1.1.2 | INTEGER | read-only | An index that uniquely identifies each ATAPI device. |
| STR cpqIdeAtapiDeviceModel | 1.3.6.1.4.1.232.14.2.5.1.1.3 | DisplayString | read-only | ATAPI Device Model. The is the model name of the ATAPI device. |
| INT cpqIdeAtapiDeviceNumber | 1.3.6.1.4.1.232.14.2.5.1.1.8 | INTEGER | read-only | ATAPI Device Number. other(1) The agent cannot determine the number of the ATAPI device. device0(2) The ATAPI device is device 0 (master). device1(3) The ATAPI device is device 1 (slave). |
| cpqIdeAtapiDeviceTable | 1.3.6.1.4.1.232.14.2.5.1 | not-accessible | IDE ATAPI Device Table. | |
| INT cpqIdeAtapiDeviceType | 1.3.6.1.4.1.232.14.2.5.1.1.5 | INTEGER | read-only | ATAPI Device Type. This is the type of ATAPI device. The following types are defined: other(1) The agent does not recognize this type. You may need to upgrade your software. disk(2) This is a direct-access device like a disk drive. tape(3) This is a sequential-access device like a tape drive. printer(4) This is a printer device. processor(5) This is a processor device. worm(6) This is a write-once, read-many times device. cd-rom(7) This is a CD or DVD device. scanner(8) This is a scanner device. optical(9) This is an optical memory device. jukeBox(10) This is a media changer device like a jukebox. commDev(11) This is a communications device like a LAN bridge. |
| INT cpqIdeAtapiDeviceTypeExtended | 1.3.6.1.4.1.232.14.2.5.1.1.6 | INTEGER | read-only | ATAPI Extended Device Type. This is additional information about the type of ATAPI device. The following types are defined: other(1) This target does not have any extended type information. pdcd(2) This is a power-drive CD-ROM. removableDisk(3) This is a removable media disk device like a floppy drive. |
| cpqIdeComponent | 1.3.6.1.4.1.232.14.2 | |||
| cpqIdeController | 1.3.6.1.4.1.232.14.2.3 | |||
| INT cpqIdeControllerCondition | 1.3.6.1.4.1.232.14.2.3.1.1.7 | INTEGER | read-only | IDE Controller Condition. This is the condition of the IDE controller. |
| cpqIdeControllerEntry | 1.3.6.1.4.1.232.14.2.3.1.1 | not-accessible | IDE Controller Table Entry. | |
| STR cpqIdeControllerFwRev | 1.3.6.1.4.1.232.14.2.3.1.1.4 | DisplayString | read-only | IDE Controller Firmware Revision. The is the IDE controller firmware revision. |
| INT cpqIdeControllerIndex | 1.3.6.1.4.1.232.14.2.3.1.1.1 | INTEGER | read-only | An index that uniquely identifies each controller. |
| STR cpqIdeControllerModel | 1.3.6.1.4.1.232.14.2.3.1.1.3 | DisplayString | read-only | IDE Controller Model. The is the IDE controller model name. |
| INT cpqIdeControllerOverallCondition | 1.3.6.1.4.1.232.14.2.3.1.1.2 | INTEGER | read-only | IDE Controller Overall Condition. This is the overall condition of the IDE controller and any associated devices. |
| STR cpqIdeControllerSerialNumber | 1.3.6.1.4.1.232.14.2.3.1.1.8 | DisplayString | read-only | IDE Controller Serial Number. The is the IDE controller serial number. A NULL string indicates that the serial number could not be determined or is irrelevant. |
| INT cpqIdeControllerSlot | 1.3.6.1.4.1.232.14.2.3.1.1.5 | INTEGER | read-only | IDE Controller Slot. This identifies the physical slot where the IDE controller resides in the system. For example, if this value is three, the controller is located in slot three of your computer. If the value cannot be determined or is not applicable, the value is set to -1. |
| INT cpqIdeControllerStatus | 1.3.6.1.4.1.232.14.2.3.1.1.6 | INTEGER | read-only | IDE Channel Host Controller Status. The host controller can be in one of the following states: Other (1) The agent is unable to determine the status of the controller. OK (2) Indicates that the controller is in normal operation mode. Failed (3) Indicates that the host controller has failed and should be replaced. |
| cpqIdeControllerTable | 1.3.6.1.4.1.232.14.2.3.1 | not-accessible | IDE Controller Table. | |
| NTF cpqIdeDriveDegraded | 1.3.6.1.4.1.232.0.14001 | An IDE drive status has been set to degraded. User Action: The drive should be scheduled for replacement. Refer to the appropriate Maintenance and Service Guide for detailed information on a component replacement. | ||
| NTF cpqIdeDriveOk | 1.3.6.1.4.1.232.0.14002 | An IDE drive status has been set to ok. User Action: None. | ||
| NTF cpqIdeDriveUltraAtaDegraded | 1.3.6.1.4.1.232.0.14003 | An IDE drive detects an excessive number of Ultra ATA data transmission errors between the hard drive and the processor. User Action: For best performance move Ultra ATA devices to the primary controller and non Ultra ATA devices to the secondary controller. If errors still persist, consider replacing the standard 40-conductor IDE cable with an 80-conductor Ultra ATA cable. | ||
| cpqIdeIdent | 1.3.6.1.4.1.232.14.2.2 | |||
| INT cpqIdeIdentCondition | 1.3.6.1.4.1.232.14.2.2.1.1.5 | INTEGER | read-only | IDE Drive Condition. This is the overall condition of the IDE drive. The following values are defined: other(1) The drive does not support drive condition monitoring. ok(2) The drive is operating normally. No user action is required. degraded(3) The drive is degraded. The drive may need to be replaced. failed(4) The drive has failed. The drive should be replaced. |
| INT cpqIdeIdentCondition2 | 1.3.6.1.4.1.232.14.2.2.1.1.9 | INTEGER | read-only | IDE Drive Condition. This is the overall condition of the IDE drive. The following values are defined: other(1) The drive does not support drive condition monitoring. ok(2) The drive is operating normally. No user action is required. degraded(3) The drive is degraded. See cpqIdeIdentStatus for the appropriate action. failed(4) The drive has failed. See cpqIdeIdentStatus for the appropriate action. |
| cpqIdeIdentEntry | 1.3.6.1.4.1.232.14.2.2.1.1 | not-accessible | IDE Identification Table Entry. | |
| STR cpqIdeIdentErrorNumber | 1.3.6.1.4.1.232.14.2.2.1.1.6 | DisplayString | read-only | IDE Error Number. This value represents the error code associated with a failing IDE drive. |
| STR cpqIdeIdentFWVers | 1.3.6.1.4.1.232.14.2.2.1.1.4 | DisplayString | read-only | IDE Firmware Version. This is the version of the firmware on the IDE drive. If the IDE drive firmware version is unavailable, then this string will be of length zero (0). |
| INT cpqIdeIdentIndex | 1.3.6.1.4.1.232.14.2.2.1.1.1 | INTEGER | read-only | An index that uniquely specifies each device. For disks, this index value will match the value of the cpqSeFixedDiskIndex in the Standard Equipment MIB (CPQSTDEQ.MIB) when the same disk is being described. Each possible index value indicates a specific drive as shown in the table below: Drive Index IDE Controller Drive Unit =========== ============== ========== 0 Primary 1 1 Primary 2 2 Secondary 1 3 Secondary 2 Any other index value would be implementation specific. |
| STR cpqIdeIdentModel | 1.3.6.1.4.1.232.14.2.2.1.1.2 | DisplayString | read-only | IDE Drive Model. The is the drive model name and can be used for identification purposes. |
| STR cpqIdeIdentSerNum | 1.3.6.1.4.1.232.14.2.2.1.1.3 | DisplayString | read-only | IDE Drive Serial Number. The is the drive serial number and can be used for identification purposes. |
| INT cpqIdeIdentStatus | 1.3.6.1.4.1.232.14.2.2.1.1.10 | INTEGER | read-only | IDE Drive Satus. This indicates the status of the IDE drive. The following values are defined: other(1) The drive does not support drive status monitoring. ok(2) The drive is operating normally. No user action is required. preFailureDegraded(3) The drive has detected that at least one pre-failure SMART attribute has gone out of range. The drive may need to be replaced. ultraAtaDegraded(4) The Ultra ATA Integrity Monitor has detected data transmission errors between the hard drive and processor. For best performance, move Ultra ATA devices to the primary controller and non Ultra ATA devices to the secondary controller. If errors still persist, consider replacing the standard 40-conductor cable with and 80-conductor cable. |
| cpqIdeIdentTable | 1.3.6.1.4.1.232.14.2.2.1 | not-accessible | IDE Drive Identification Table. | |
| INT cpqIdeIdentType | 1.3.6.1.4.1.232.14.2.2.1.1.7 | INTEGER | read-only | IDE Device Type. This is the type of ATAPI device. The following types are defined: other(1) The Insight agent does not recognize this type. You may need to upgrade your software. disk(2) This is a direct-access device like a disk drive. tape(3) This is a sequential-access device like a tape drive. printer(4) This is a printer device. processor(5) This is a processor device. worm(6) This is a write-once, read-many times device. cd-rom(7) This is a CD or DVD device. scanner(8) This is a scanner device. optical(9) This is an optical memory device. jukeBox(10) This is a media changer device like a jukebox. commDev(11) This is a communications device like a LAN bridge. |
| INT cpqIdeIdentTypeExtended | 1.3.6.1.4.1.232.14.2.2.1.1.8 | INTEGER | read-only | IDE Extended Device Type. This is additional information about the type of IDE device. The following types are defined: other(1) This target does not have any extended type information. pdcd(2) This is a power-drive CD-ROM. removableDisk(3) This is a removable media disk device like a floppy drive. |
| INT cpqIdeIdentUltraAtaAvailability | 1.3.6.1.4.1.232.14.2.2.1.1.11 | INTEGER | read-only | This describes the availability of Ultra ATA transfers between this device and the controller. The following values are defined: other(1) The agents do not support reporting this variable or the agent need to be upgraded. noNotSupportedByDeviceAndController(2), The device and the controller do not support Ultra ATA. noNotSupportedByDevice(3), The device does not support Ultra ATA but the controller does support Ultra ATA. noNotSupportedByController(4), The controller does not support Ultra ATA but the device does support Ultra ATA. NoDisabledInSetup(5), The device and the controller do support Ultra ATA but it has been disabled in F10 Setup. yesEnabledInSetup(6), The device and the controller do support Ultra ATA and it is enabled in F10 Setup. |
| cpqIdeInterface | 1.3.6.1.4.1.232.14.2.1 | |||
| cpqIdeLogicalDrive | 1.3.6.1.4.1.232.14.2.6 | |||
| INT cpqIdeLogicalDriveCapacity | 1.3.6.1.4.1.232.14.2.6.1.1.4 | INTEGER | read-only | IDE Logical Drive Capacity. This is the capacity of the logical drive in megabytes. |
| INT cpqIdeLogicalDriveCondition | 1.3.6.1.4.1.232.14.2.6.1.1.6 | INTEGER | read-only | IDE Logical Drive Condition. This is the condition of the logical drive. |
| INT cpqIdeLogicalDriveControllerIndex | 1.3.6.1.4.1.232.14.2.6.1.1.1 | INTEGER | read-only | An index that uniquely identifies each controller. |
| OCT cpqIdeLogicalDriveDiskIds | 1.3.6.1.4.1.232.14.2.6.1.1.7 | OCTET STRING | read-only | IDE Logical Drive Disk ID list. This lists the ATA disks drive IDs which are associated with this logical drive. These are the same IDs which can be used as indices into the ATA disk table (cpqIdeAtaDiskIndex). Each byte of the string is an index. |
| cpqIdeLogicalDriveEntry | 1.3.6.1.4.1.232.14.2.6.1.1 | not-accessible | IDE Logical Drive Table Entry. | |
| INT cpqIdeLogicalDriveIndex | 1.3.6.1.4.1.232.14.2.6.1.1.2 | INTEGER | read-only | An index that uniquely identifies each logical drive. |
| STR cpqIdeLogicalDriveOsName | 1.3.6.1.4.1.232.14.2.6.1.1.11 | DisplayString | read-only | IDE Logical Drive OS Name. The OS name for this logical drive. This field will be a null (size 0) string if the agent does not support OS name. |
| INT cpqIdeLogicalDriveRaidLevel | 1.3.6.1.4.1.232.14.2.6.1.1.3 | INTEGER | read-only | IDE Logical Drive RAID Level. The following RAID levels are defined: other(1) The agent cannot determine the RAID level of this logical drive. raid0(2) The logical drive is configured with RAID level 0. raid1(3) The logical drive is configured with RAID level 1. raid0plus1(4) The logical drive is configured with RAID level 0 plus 1. raid5(5) The logical drive is configured with RAID level 5. raid15(6) The logical drive is configured with RAID level 1 plus 5. volume(7) The logical drive is configured as a volume set. |
| INT cpqIdeLogicalDriveRebuildingDisk | 1.3.6.1.4.1.232.14.2.6.1.1.10 | INTEGER | read-only | IDE Logical Drive Rebuilding Disk. This is the ATA disk that is in the process of rebuilding. If no drive is currently rebuilding, a value of -1 will be returned. |
| OCT cpqIdeLogicalDriveSpareIds | 1.3.6.1.4.1.232.14.2.6.1.1.9 | OCTET STRING | read-only | IDE Logical Drive Spare ID list. This lists the ATA disks drive IDs which are possible spares for this logical drive. These are the same IDs which can be used as indices into the ATA disk table (cpqIdeAtaDiskIndex). Each byte of the string is an index. |
| INT cpqIdeLogicalDriveStatus | 1.3.6.1.4.1.232.14.2.6.1.1.5 | INTEGER | read-only | IDE Logical Drive Status. This is the status of the logical drive. other(1) The agent cannot determine the logical drive status. ok(2) Indicates that the logical drive is in normal operation mode. degraded(3) Indicates that at least one physical drive has failed, but the logical drive's RAID level lets the drive continue to operate with no data loss. rebuilding(4) Indicates that the logical drive is rebuilding a physical drive. When complete, the logical drive will return to normal operation. failed(5) Indicates that more physical drives have failed than the RAID level of the logical drive can handle without data loss. |
| NTF cpqIdeLogicalDriveStatusChange | 1.3.6.1.4.1.232.0.14005 | IDE Logical Drive Status Change. This trap signifies that the agent has detected a change in the status of an IDE logical drive. The variable cpqIdeLogicalDriveStatus indicates the current logical drive status. User Action: If the logical drive status is failed(5), examine the array for failed drives that need replacement. | ||
| INT cpqIdeLogicalDriveStripeSize | 1.3.6.1.4.1.232.14.2.6.1.1.8 | INTEGER | read-only | IDE Logical Drive Stripe Size. This is the stripe size in kilobytes. |
| cpqIdeLogicalDriveTable | 1.3.6.1.4.1.232.14.2.6.1 | not-accessible | IDE Logical Drive Table. | |
| INT cpqIdeMibCondition | 1.3.6.1.4.1.232.14.1.3 | INTEGER | read-only | The overall condition. This object represents the overall status of the Ide system represented by this MIB. |
| cpqIdeMibRev | 1.3.6.1.4.1.232.14.1 | |||
| INT cpqIdeMibRevMajor | 1.3.6.1.4.1.232.14.1.1 | INTEGER | read-only | The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information, correct interpretation of data may require a MIB document with the same major revision level. |
| INT cpqIdeMibRevMinor | 1.3.6.1.4.1.232.14.1.2 | INTEGER | read-only | The Minor Revision level. A change in the minor revision level may represent some minor additional support; no changes to any pre-existing information has occurred. |
| cpqIdeOsCommon | 1.3.6.1.4.1.232.14.2.1.4 | |||
| OCT cpqIdeOsCommonModuleDate | 1.3.6.1.4.1.232.14.2.1.4.2.1.4 | OCTET STRING | read-only | The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the module date. The hour, minute, and second field will be set to zero (0) if they are not relevant. |
| cpqIdeOsCommonModuleEntry | 1.3.6.1.4.1.232.14.2.1.4.2.1 | not-accessible | A description of a software modules that provide an interface to the device this MIB describes. | |
| INT cpqIdeOsCommonModuleIndex | 1.3.6.1.4.1.232.14.2.1.4.2.1.1 | INTEGER | read-only | A unique index for this module description. |
| STR cpqIdeOsCommonModuleName | 1.3.6.1.4.1.232.14.2.1.4.2.1.2 | DisplayString | read-only | The module name. |
| STR cpqIdeOsCommonModulePurpose | 1.3.6.1.4.1.232.14.2.1.4.2.1.5 | DisplayString | read-only | The purpose of the module described in this entry. |
| cpqIdeOsCommonModuleTable | 1.3.6.1.4.1.232.14.2.1.4.2 | not-accessible | A table of software modules that provide an interface to the device this MIB describes. | |
| STR cpqIdeOsCommonModuleVersion | 1.3.6.1.4.1.232.14.2.1.4.2.1.3 | DisplayString | read-only | The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be a null (size 0) string if the agent cannot provide the module version. |
| INT cpqIdeOsCommonPollFreq | 1.3.6.1.4.1.232.14.2.1.4.1 | INTEGER | read-write | The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero indicates that the Insight Agent retrieves the information upon request of a management station, it does not poll the device driver at a specific interval. If the poll frequency is zero (0) all attempts to write to this object will fail. If the poll frequency is non-zero, setting this value will change the polling frequency of the Insight Agent. Setting the poll frequency to zero will always fail, an agent may also choose to fail any request to change the poll frequency to a value that would severely impact system performance. |
RFC description
Manages IDE and ATA disk drives including controllers, logical drives, and status monitoring on Compaq servers.
Start monitoring HP/Compaq ProLiant server (IDE/ATA disk drives) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.