HH3C-LOGIC-VOLUME-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HH3C-LOGIC-VOLUME-MIB

Organization: H3C Technologies Co., Ltd.

Last Updated: 2007-09-04

Category: Domain: Storage, Hardware and Environment, Vendor: H3C/HH3C

Description: Manages logical storage volumes on H3C platforms including RAID groups and volume health status.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is HH3C-LOGIC-VOLUME-MIB?

HH3C-LOGIC-VOLUME-MIB is an H3C enterprise MIB for managing logical storage volumes on H3C storage/converged platforms, covering logical volume (LV) creation, RAID-group-backed volume definitions, and related SAN client/initiator/target counts. It exposes both summary capacity data (counts of logical volumes, targets, initiators, and SAN clients, plus maximum volume size) and a detailed per-volume table with each volume's name, total size, and the RAID UUID it was created from. As a monitoring tool it is squarely about disk/storage health: an administrator can track how many logical volumes exist versus capacity limits, confirm a given volume's size and its backing RAID group, and detect unexpected changes in volume count or size that could indicate a storage provisioning problem or failed RAID rebuild. It is a storage-focused MIB likely used alongside H3C's broader hardware/chassis MIBs for physical disk and RAID controller status, though no explicit standard-MIB dependency is stated. It is typically deployed on H3C storage arrays, converged infrastructure, or servers with SAN/iSCSI targets managed under H3C's device management framework. Engineers can download the HH3C-LOGIC-VOLUME-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in HH3C-LOGIC-VOLUME-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • H3C storage arrays / converged storage platforms

Monitoring Examples

An administrator would check hh3cLvCount against hh3cLvMaxSize-related capacity limits, then walk hh3cLvTable/hh3cLvEntry to inspect each hh3cLvIndex's hh3cLvName, hh3cLvTotalSize, and hh3cLvCreateRaidUuid. A logical volume whose hh3cLvTotalSize suddenly reports zero or an unexpected hh3cLvCreateRaidUuid would suggest the underlying RAID group failed or was reconfigured, while tracking hh3cTargetCount and hh3cInitiatorCount helps confirm the expected number of SAN clients are still connected via hh3cSanClientCount.

What Can Be Monitored

  • logical volume count and size
  • RAID group association per volume
  • SAN target count
  • SAN initiator count
  • connected SAN client count
Imported Objects

From ENTITY-MIB

entPhysicalIndexOBJECT-TYPE

From HH3C-STORAGE-REF-MIB

Hh3cLvIDType
Hh3cRaidIDType
Hh3cSessionIDType
Hh3cStorageActionType
Hh3cStorageEnableState
Hh3cStorageLedStateType
Hh3cWwpnListType
hh3cStorageRefMODULE-IDENTITY

From INET-ADDRESS-MIB

InetAddress
InetAddressType

From SNMPv2-SMI

Counter32
Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE

From SNMPv2-TC

DateAndTime
RowStatus
TEXTUAL-CONVENTION
TruthValue

How to Use in IPNetwork Monitor

Example using hh3cTISessionConnectionCount OID:

Select an H3C storage array/converged storage platform (logical volume management) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hh3cTISessionConnectionCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This object describes the number of connections between the targets and initiators. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

H3C logical volume and disk storage device management including RAID and capacity.

Start monitoring H3C storage array/converged storage platform (logical volume management) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download HH3C-LOGIC-VOLUME-MIB