| OID symbolic | OID numeric | Type | Access | Description |
| fastPathBoxServices | 1.3.6.1.4.1.4413.1.1.43 | | | The Ubiquiti Private MIB for EdgeSwitch Box Services Feature. |
| fastPathBoxServicesTraps | 1.3.6.1.4.1.4413.1.1.43.0 | | | |
| NTF boxsFanStateChange | 1.3.6.1.4.1.4413.1.1.43.0.1 | | | Trap is sent when fan state change happens. |
| NTF boxsPowSupplyStateChange | 1.3.6.1.4.1.4413.1.1.43.0.2 | | | Trap is sent when power supply state change happens. |
| NTF boxsTemperatureChange | 1.3.6.1.4.1.4413.1.1.43.0.3 | | | Trap is sent when temperature is changing and crossing any of the thresholds |
| NTF boxsThermalShutdown | 1.3.6.1.4.1.4413.1.1.43.0.4 | | | Trap is sent when thermal shutdown is initiated. |
| NTF boxsTemperatureStateChange | 1.3.6.1.4.1.4413.1.1.43.0.5 | | | Trap is sent when the system temperature crosses a threshold.
To avoid rapid flapping between states, a hysteresis may
be applied. |
| boxServicesGroup | 1.3.6.1.4.1.4413.1.1.43.1 | | | |
| I32 boxServicesNormalTempRangeMin | 1.3.6.1.4.1.4413.1.1.43.1.1 | Integer32 | read-write | Lower boundary of normal temperature range. |
| I32 boxServicesNormalTempRangeMax | 1.3.6.1.4.1.4413.1.1.43.1.2 | Integer32 | read-write | Upper boundary of normal temperature range. |
| INT boxServicesTemperatureTrapEnable | 1.3.6.1.4.1.4413.1.1.43.1.3 | INTEGER | read-write | Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range |
| INT boxServicesPSMStateTrapEnable | 1.3.6.1.4.1.4413.1.1.43.1.4 | INTEGER | read-write | Enable or disable Power Supply Module state change trap. |
| INT boxServicesFanStateTrapEnable | 1.3.6.1.4.1.4413.1.1.43.1.5 | INTEGER | read-write | Enable or disable Fan state change trap. |
| boxServicesFansTable | 1.3.6.1.4.1.4413.1.1.43.1.6 | | not-accessible | Fan |
| boxServicesFansEntry | 1.3.6.1.4.1.4413.1.1.43.1.6.1 | | not-accessible | Box Services Fan Entry |
| I32 boxServicesFansIndex | 1.3.6.1.4.1.4413.1.1.43.1.6.1.1 | Integer32 | read-only | Unique index of fan table entry |
| INT boxServicesFanItemType | 1.3.6.1.4.1.4413.1.1.43.1.6.1.2 | INTEGER | read-only | The type of fan |
| INT boxServicesFanItemState | 1.3.6.1.4.1.4413.1.1.43.1.6.1.3 | INTEGER | read-only | The status of fan. nopower(4) - This state means the fan is present but no AC is connected. |
| OCT boxServicesFanSpeed | 1.3.6.1.4.1.4413.1.1.43.1.6.1.4 | OCTET STRING | read-only | The speed of fan |
| OCT boxServicesFanDutyLevel | 1.3.6.1.4.1.4413.1.1.43.1.6.1.5 | OCTET STRING | read-only | The duty level of fan, in percents |
| U32 boxServicesFanUnitIndex | 1.3.6.1.4.1.4413.1.1.43.1.6.1.6 | Unsigned32 | read-only | Unit index for an entry in the Box Services Fan Table |
| boxServicesPowSuppliesTable | 1.3.6.1.4.1.4413.1.1.43.1.7 | | not-accessible | Power supply |
| boxServicesPowSuppliesEntry | 1.3.6.1.4.1.4413.1.1.43.1.7.1 | | not-accessible | Box Services Power Supply Entry |
| I32 boxServicesPowSupplyIndex | 1.3.6.1.4.1.4413.1.1.43.1.7.1.1 | Integer32 | read-only | Unique index of power supply table entry |
| INT boxServicesPowSupplyItemType | 1.3.6.1.4.1.4413.1.1.43.1.7.1.2 | INTEGER | read-only | The type of power supply |
| INT boxServicesPowSupplyItemState | 1.3.6.1.4.1.4413.1.1.43.1.7.1.3 | INTEGER | read-only | The status of power supply. nopower(5) - This state means the power supply is present but no AC is connected.
incompatible(7) - This state is possible on boards capable of pluggable Power supplies |
| U32 boxServicesPowerSuppUnitIndex | 1.3.6.1.4.1.4413.1.1.43.1.7.1.4 | Unsigned32 | read-only | Unit index for an entry in the Box Services Power Supply Table |
| boxServicesTempSensorsTable | 1.3.6.1.4.1.4413.1.1.43.1.8 | | not-accessible | Temperature sensor |
| boxServicesTempSensorsEntry | 1.3.6.1.4.1.4413.1.1.43.1.8.1 | | not-accessible | Box Services Temperature Sensor Entry |
| U32 boxServicesUnitIndex | 1.3.6.1.4.1.4413.1.1.43.1.8.1.1 | Unsigned32 | read-only | Unit index for an entry in the Box Services Temperature Sensor Table |
| U32 boxServicesTempSensorIndex | 1.3.6.1.4.1.4413.1.1.43.1.8.1.2 | Unsigned32 | read-only | Unique index of temperature sensor table entry |
| INT boxServicesTempSensorType | 1.3.6.1.4.1.4413.1.1.43.1.8.1.3 | INTEGER | read-only | The type of temperature sensor |
| BOX boxServicesTempSensorState | 1.3.6.1.4.1.4413.1.1.43.1.8.1.4 | BoxsTemperatureStatus | read-only | The state of temperature sensor |
| I32 boxServicesTempSensorTemperature | 1.3.6.1.4.1.4413.1.1.43.1.8.1.5 | Integer32 | read-only | The temperature value reported by sensor |
| U32 boxServicesThermalShutdownSensor | 1.3.6.1.4.1.4413.1.1.43.1.13 | Unsigned32 | accessible-for-notify | The number of the sensor which initiated thermal shutdown. |
| U32 boxServicesThermalShutdownTemperature | 1.3.6.1.4.1.4413.1.1.43.1.14 | Unsigned32 | accessible-for-notify | The temperature of the sensor which initiated thermal shutdown. |
| boxServicesTempUnitTable | 1.3.6.1.4.1.4413.1.1.43.1.15 | | not-accessible | Temperature status table |
| boxServicesTempUnitEntry | 1.3.6.1.4.1.4413.1.1.43.1.15.1 | | not-accessible | Box Services Temperature Unit Entry |
| U32 boxServicesTempUnitIndex | 1.3.6.1.4.1.4413.1.1.43.1.15.1.1 | Unsigned32 | read-only | Unit index for an entry in the Box Services Temperature Unit Table |
| BOX boxServicesTempUnitState | 1.3.6.1.4.1.4413.1.1.43.1.15.1.2 | BoxsTemperatureStatus | read-only | The temperature state of the unit |
| I32 boxServicesTempUnitTemperature | 1.3.6.1.4.1.4413.1.1.43.1.15.1.3 | Integer32 | read-only | The highest temperature currently reported by any sensor on the unit |
| boxServicesNotificationsGroup | 1.3.6.1.4.1.4413.1.1.43.2 | | | |
| INT boxsItemStateChangeEvent | 1.3.6.1.4.1.4413.1.1.43.2.1 | INTEGER | accessible-for-notify | This event describes states of the fan or power supply.
insertion - hot-pluggable fan or power supply was inserted
removal - hot-pluggable fan or power supply was removed
becomeoperational - fan or power supply became operational after failure state
failure - fan or power supply failure happened, i.e. it is not able to perform its functions
losepower - a power supply was operational, but the power to it has been disconnected or has failed |
| INT boxsTemperatureChangeEvent | 1.3.6.1.4.1.4413.1.1.43.2.2 | INTEGER | accessible-for-notify | This event describes change of the temperature.
To avoid flipping on boundary conditions, it is allowed to send the trap
taking into account some margin around thresholds.
abovethreshold - temperature increased and crossed upper threshold value
belowthreshold - temperature decreased and crossed lower threshold value
withinnormalrange - temperature returned to normal range (between threshold) |
| BOX boxsTemperatureStatusCurrentEvent | 1.3.6.1.4.1.4413.1.1.43.2.3 | BoxsTemperatureStatus | accessible-for-notify | This event describes the current status of a switch. |
| BOX boxsTemperatureStatusPreviousEvent | 1.3.6.1.4.1.4413.1.1.43.2.4 | BoxsTemperatureStatus | accessible-for-notify | This event describes the previous status of a switch. |
| boxsLocatorLedConfigGroup | 1.3.6.1.4.1.4413.1.1.43.4 | | | |
| INT boxsLocatorLedUnit | 1.3.6.1.4.1.4413.1.1.43.4.1 | INTEGER | read-write | Spesifies unit number where Locator LED should blink on.
This is write-only value. It always returns '0' on request
if the Locator Led feature is supported. |
| INT boxsLocatorLedTime | 1.3.6.1.4.1.4413.1.1.43.4.2 | INTEGER | read-write | Indicates time period in seconds for Locator LED blinking.
The range is from 20 to 3600 seconds.
The dafault value is 20 seconds.
This is write-only value. It always returns '0' on request
if the Locator Led feature is supported. |
| INT boxsLocatorLedEnable | 1.3.6.1.4.1.4413.1.1.43.4.3 | INTEGER | read-write | Starts the Locator LED blinking.
If boxsLocatorLedUnit has not been set current(manager) unit number will be used.
If boxsLocatorLedTime has not been set default value(20 seconds) will be used.
This is write-only value. It always returns '0' on request
if the Locator Led feature is supported. |