AT-ENVMON-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › AT-ENVMON-MIB

Organization: Allied Telesis, Inc

Last Updated: 2006-03-07

Category: Hardware and Environment, Vendor: Allied Telesis

Description: Monitors environmental sensors including temperature, fan speed, and power supply status on Allied Telesis switches.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is AT-ENVMON-MIB?

AT-ENVMON-MIB is an Allied Telesis-proprietary Environment Monitoring MIB used to report physical environmental conditions on Allied Telesis switches. It exposes sensor data covering voltage rail readings, fan speed(s), temperature sensor readings, and power supply unit status. This is fundamentally a hardware-health monitoring MIB: it is used to detect overheating, fan failure, voltage rail deviations, and power supply faults, all leading indicators of impending hardware failure in a switch chassis. As a private enterprise MIB it has no dependency on IETF standards, though it fills the same functional role as the more general-purpose ENTITY-SENSOR-MIB used by other vendors. It is deployed on Allied Telesis switches in enterprise and data center environments where administrators need proactive alerts on cooling, power, and voltage health to prevent unplanned hardware outages. Engineers can download the AT-ENVMON-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in AT-ENVMON-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Allied Telesis switches

Monitoring Examples

No sample objects were extracted for this module in the source, so specific object names cannot be confirmed, but consistent with its stated purpose an administrator would poll per-sensor temperature and fan-speed readings alongside power supply and voltage-rail status objects for the switch chassis. A temperature reading trending upward alongside a fan speed reading dropping to zero would be a clear pre-failure signal of a fan malfunction risking thermal shutdown, and a power supply status changing from normal to failed would trigger an immediate hardware-fault alert.

What Can Be Monitored

  • temperature sensor readings
  • fan speed
  • voltage rail readings
  • power supply unit status
Imported Objects

From AT-SMI-MIB

DisplayStringUnsized

From AT-SYSINFO-MIB

sysinfoMODULE-IDENTITY

From IF-MIB

ifIndexOBJECT-TYPE

From SNMPv2-SMI

MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
Unsigned32
enterprises

From SNMPv2-TC

TEXTUAL-CONVENTION
TruthValue

How to Use in IPNetwork Monitor

Example using envMonVoltageCurrent OID:

Select an Allied Telesis managed switch or router as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type envMonVoltageCurrent into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The current reading of this voltage rail in millivolts. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the reading drifts outside the range expected for healthy operation, since an unexpected voltage swing often points to a power-supply or wiring issue. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Allied Telesis environment monitoring MIB for managing voltage rails, fan speeds, temperature sensors, and power supplies.

Start monitoring Allied Telesis managed switches and routers with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.