| OID symbolic | OID numeric | Type | Access | Description |
| cie1000SysutilMib | 1.3.6.1.4.1.9.9.832.1.24 | | | This is a private version of SysUtil |
| cie1000SysutilMibObjects | 1.3.6.1.4.1.9.9.832.1.24.1 | | | |
| cie1000SysutilCapabilities | 1.3.6.1.4.1.9.9.832.1.24.1.1 | | | |
| T/F cie1000SysutilCapabilitiesWarmRebootSupported | 1.3.6.1.4.1.9.9.832.1.24.1.1.1 | TruthValue | read-only | Indicate if warm restart is supported or not. true means it is
supported. false means it is not supported. |
| T/F cie1000SysutilCapabilitiesPostSupported | 1.3.6.1.4.1.9.9.832.1.24.1.1.2 | TruthValue | read-only | Indicate if POST(Power On Self Test) is supported or not. true(1) means
it is supported. false(2) means it is not supported. |
| T/F cie1000SysutilCapabilitiesZtpSupported | 1.3.6.1.4.1.9.9.832.1.24.1.1.3 | TruthValue | read-only | Indicate if ZTP(Zero Touch Provisioning) is supported or not. true(1)
means it is supported. false(2) means it is not supported. |
| T/F cie1000SysutilCapabilitiesStackFwChkSupported | 1.3.6.1.4.1.9.9.832.1.24.1.1.4 | TruthValue | read-only | Indicate if stack firmware version check is supported or not. true(1)
means it is supported. false(2) means it is not supported. |
| cie1000SysutilConfig | 1.3.6.1.4.1.9.9.832.1.24.1.2 | | | |
| cie1000SysutilConfigSystemInfo | 1.3.6.1.4.1.9.9.832.1.24.1.2.1 | | | |
| STR cie1000SysutilConfigSystemInfoHostname | 1.3.6.1.4.1.9.9.832.1.24.1.2.1.1 | CIE1000DisplayString | read-write | Hostname |
| STR cie1000SysutilConfigSystemInfoContact | 1.3.6.1.4.1.9.9.832.1.24.1.2.1.2 | CIE1000DisplayString | read-write | Contact name. |
| STR cie1000SysutilConfigSystemInfoLocation | 1.3.6.1.4.1.9.9.832.1.24.1.2.1.3 | CIE1000DisplayString | read-write | Location. |
| cie1000SysutilConfigSystemTime | 1.3.6.1.4.1.9.9.832.1.24.1.2.2 | | | |
| STR cie1000SysutilConfigSystemTimeSystemCurTime | 1.3.6.1.4.1.9.9.832.1.24.1.2.2.1 | CIE1000DisplayString | read-write | Current system time |
| STR cie1000SysutilConfigSystemTimeSystemCurTimeFormat | 1.3.6.1.4.1.9.9.832.1.24.1.2.2.2 | CIE1000DisplayString | read-write | Format for setting up current system time |
| cie1000SysutilConfigTemperatureMonitorTable | 1.3.6.1.4.1.9.9.832.1.24.1.2.3 | | not-accessible | Table of temperature monitor config. |
| cie1000SysutilConfigTemperatureMonitorEntry | 1.3.6.1.4.1.9.9.832.1.24.1.2.3.1 | | not-accessible | Each row set the sensor config. |
| CIE cie1000SysutilConfigTemperatureMonitorSensorId | 1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.1 | CIE1000SysutilTemperatureMonitorSensorType | accessible-for-notify | The identification of sensor for tempeature monitor. |
| I32 cie1000SysutilConfigTemperatureMonitorLowThreshold | 1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.2 | Integer32 | read-write | The low threshold of temperature monior. |
| I32 cie1000SysutilConfigTemperatureMonitorHighThreshold | 1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.3 | Integer32 | read-write | The high threshold of temperature monior. |
| I32 cie1000SysutilConfigTemperatureMonitorCriticalThreshold | 1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.4 | Integer32 | read-write | The critical threshold of temperature monior. |
| I32 cie1000SysutilConfigTemperatureMonitorHysteresis | 1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.5 | Integer32 | read-write | The value of hysteresis for temperature check. |
| cie1000SysutilStatus | 1.3.6.1.4.1.9.9.832.1.24.1.3 | | | |
| cie1000SysutilStatusCpuLoad | 1.3.6.1.4.1.9.9.832.1.24.1.3.1 | | | |
| U32 cie1000SysutilStatusCpuLoadAverage100msec | 1.3.6.1.4.1.9.9.832.1.24.1.3.1.1 | Unsigned32 | read-only | Average CPU load (%) in 100 milli-seconds. |
| U32 cie1000SysutilStatusCpuLoadAverage1sec | 1.3.6.1.4.1.9.9.832.1.24.1.3.1.2 | Unsigned32 | read-only | Average CPU load (%) in 1 second. |
| U32 cie1000SysutilStatusCpuLoadAverage10sec | 1.3.6.1.4.1.9.9.832.1.24.1.3.1.3 | Unsigned32 | read-only | Average CPU load (%) in 10 seconds. |
| cie1000SysutilStatusPowerSupplyTable | 1.3.6.1.4.1.9.9.832.1.24.1.3.2 | | not-accessible | Table of power supply status. |
| cie1000SysutilStatusPowerSupplyEntry | 1.3.6.1.4.1.9.9.832.1.24.1.3.2.1 | | not-accessible | Each row contains the power supply status. |
| I32 cie1000SysutilStatusPowerSupplySwitchId | 1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.1 | Integer32 | accessible-for-notify | The identification of switch. |
| I32 cie1000SysutilStatusPowerSupplyPsuId | 1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.2 | Integer32 | accessible-for-notify | The identification of power supply. |
| CIE cie1000SysutilStatusPowerSupplyState | 1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.3 | CIE1000SysutilPowerSupplyStateType | read-only | The state of power supply. |
| STR cie1000SysutilStatusPowerSupplyDescription | 1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.4 | CIE1000DisplayString | read-only | The description of power supply. |
| cie1000SysutilStatusSystemLedTable | 1.3.6.1.4.1.9.9.832.1.24.1.3.3 | | not-accessible | Table of system LED status. |
| cie1000SysutilStatusSystemLedEntry | 1.3.6.1.4.1.9.9.832.1.24.1.3.3.1 | | not-accessible | Each row contains the system LED status. |
| I32 cie1000SysutilStatusSystemLedSwitchId | 1.3.6.1.4.1.9.9.832.1.24.1.3.3.1.1 | Integer32 | accessible-for-notify | The identification of switch. |
| STR cie1000SysutilStatusSystemLedDescription | 1.3.6.1.4.1.9.9.832.1.24.1.3.3.1.2 | CIE1000DisplayString | read-only | The description of system LED status. |
| cie1000SysutilStatusSystemUptime | 1.3.6.1.4.1.9.9.832.1.24.1.3.4 | | | |
| STR cie1000SysutilStatusSystemUptimeSystemUptime | 1.3.6.1.4.1.9.9.832.1.24.1.3.4.1 | CIE1000DisplayString | read-only | The time since the DUT is Up. |
| cie1000SysutilStatusBoardInfo | 1.3.6.1.4.1.9.9.832.1.24.1.3.5 | | | |
| MAC cie1000SysutilStatusBoardInfoBoardMacAddress | 1.3.6.1.4.1.9.9.832.1.24.1.3.5.1 | MacAddress | read-only | Board Mac Address |
| U32 cie1000SysutilStatusBoardInfoBoardID | 1.3.6.1.4.1.9.9.832.1.24.1.3.5.2 | Unsigned32 | read-only | Board ID |
| STR cie1000SysutilStatusBoardInfoBoardSerial | 1.3.6.1.4.1.9.9.832.1.24.1.3.5.3 | CIE1000DisplayString | read-only | Board ID |
| STR cie1000SysutilStatusBoardInfoBoardType | 1.3.6.1.4.1.9.9.832.1.24.1.3.5.4 | CIE1000DisplayString | read-only | Board ID |
| STR cie1000SysutilStatusBoardInfoCipSerial | 1.3.6.1.4.1.9.9.832.1.24.1.3.5.5 | CIE1000DisplayString | read-only | Board CIP serial number |
| cie1000SysutilStatusTemperatureMonitorTable | 1.3.6.1.4.1.9.9.832.1.24.1.3.6 | | not-accessible | Table of temperature monitor status. |
| cie1000SysutilStatusTemperatureMonitorEntry | 1.3.6.1.4.1.9.9.832.1.24.1.3.6.1 | | not-accessible | Each row contains the sensor status. |
| CIE cie1000SysutilStatusTemperatureMonitorSensorId | 1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.1 | CIE1000SysutilTemperatureMonitorSensorType | accessible-for-notify | The identification of sensor for tempeature monitor. |
| T/F cie1000SysutilStatusTemperatureMonitorLowAlarm | 1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.2 | TruthValue | read-only | The alarm flag of temperature low status. |
| T/F cie1000SysutilStatusTemperatureMonitorHighAlarm | 1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.3 | TruthValue | read-only | The alarm flag of temperature high status. |
| T/F cie1000SysutilStatusTemperatureMonitorCriticalAlarm | 1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.4 | TruthValue | read-only | The alarm flag of temperature critical status. |
| I32 cie1000SysutilStatusTemperatureMonitorTemperature | 1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.5 | Integer32 | read-only | Current temperature. |
| cie1000SysutilStatusLedStatus | 1.3.6.1.4.1.9.9.832.1.24.1.3.7 | | | |
| cie1000SysutilStatusLedStatusSystemTable | 1.3.6.1.4.1.9.9.832.1.24.1.3.7.1 | | not-accessible | The table is the list of LED nodes. The index is the name of the LED
node |
| cie1000SysutilStatusLedStatusSystemEntry | 1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1 | | not-accessible | An index is a name e.g. alm |
| CIE cie1000SysutilStatusLedStatusSystemLedId | 1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.1 | CIE1000SysutilLedNameIndex | accessible-for-notify | The identification of the system LED. |
| CIE cie1000SysutilStatusLedStatusSystemLedColor | 1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.2 | CIE1000SysutilLedColor | read-only | Color of LED. off(0) - The led is off, green(1) - The led is green,
red(2) - The led is red, amber(3) - The led is amber, green_red(4) -
The led is bi-color greed red, green_amber(5) - The led is bi-color
green amber. |
| CIE cie1000SysutilStatusLedStatusSystemLedMode | 1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.3 | CIE1000SysutilLedMode | read-only | Type of LED mode.initial(0) Initial state. solid(1) LED is solid
on.off(2) LED is turned off.blinking(3) LED is blinking.alternative(4)
LED is in alternative mode. |
| STR cie1000SysutilStatusLedStatusSystemDescription | 1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.4 | CIE1000DisplayString | read-only | The description of system LED status. |
| cie1000SysutilStatusLedStatusPortTable | 1.3.6.1.4.1.9.9.832.1.24.1.3.7.2 | | not-accessible | The table is the list of port interface LED nodes. The index is the
port interface |
| cie1000SysutilStatusLedStatusPortEntry | 1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1 | | not-accessible | Port interface |
| NUM cie1000SysutilStatusLedStatusPortIfIndex | 1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.1 | CIE1000InterfaceIndex | accessible-for-notify | Logical interface number. |
| CIE cie1000SysutilStatusLedStatusPortLedColor | 1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.2 | CIE1000SysutilLedColor | read-only | Color of LED. off(0) - The led is off, green(1) - The led is green,
red(2) - The led is red, amber(3) - The led is amber, green_red(4) -
The led is bi-color greed red, green_amber(5) - The led is bi-color
green amber. |
| CIE cie1000SysutilStatusLedStatusPortLedMode | 1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.3 | CIE1000SysutilLedMode | read-only | Type of LED mode.initial(0) Initial state. solid(1) LED is solid
on.off(2) LED is turned off.blinking(3) LED is blinking.alternative(4)
LED is in alternative mode. |
| STR cie1000SysutilStatusLedStatusPortDescription | 1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.4 | CIE1000DisplayString | read-only | The description of system LED status. |
| cie1000SysutilControl | 1.3.6.1.4.1.9.9.832.1.24.1.4 | | | |
| cie1000SysutilControlRebootTable | 1.3.6.1.4.1.9.9.832.1.24.1.4.1 | | not-accessible | This is a table to reboot a swicth |
| cie1000SysutilControlRebootEntry | 1.3.6.1.4.1.9.9.832.1.24.1.4.1.1 | | not-accessible | Each switch has a set of parameters |
| I32 cie1000SysutilControlRebootSwitchId | 1.3.6.1.4.1.9.9.832.1.24.1.4.1.1.1 | Integer32 | accessible-for-notify | The identification of switch. |
| CIE cie1000SysutilControlRebootType | 1.3.6.1.4.1.9.9.832.1.24.1.4.1.1.2 | CIE1000SysutilRebootType | read-write | Type of reboot. noReboot(0) does not reboot. coldReboot(1) is to do
cold reboot. warmReboot(2) is to do warm reboot, but this is optional.
The OID of vtssSysutilCapabilitiesWarmRebootSupported tells if warm
reboot is supported or not. factoryReset (3) is to remove all
configuration and return to factory settings. |
| cie1000SysutilControlSystemLedTable | 1.3.6.1.4.1.9.9.832.1.24.1.4.2 | | not-accessible | This is a table to clear the system LED error status |
| cie1000SysutilControlSystemLedEntry | 1.3.6.1.4.1.9.9.832.1.24.1.4.2.1 | | not-accessible | Each switch has a set of parameters |
| I32 cie1000SysutilControlSystemLedSwitchId | 1.3.6.1.4.1.9.9.832.1.24.1.4.2.1.1 | Integer32 | accessible-for-notify | The identification of switch. |
| CIE cie1000SysutilControlSystemLedClearStatus | 1.3.6.1.4.1.9.9.832.1.24.1.4.2.1.2 | CIE1000SysutilSystemLedClearType | read-write | Type of system LED status clearing.all(0) is used to clear all error
status of the system LED and back to normal indication. fatal(1) is
used to clear fatal error status of the system LED. software(2) is used
to clear generic software error status of the system LED. post(3) is
used to clear POST(Power On Self Test) error status of the system LED.
ztp(4) is used to clear ZTP(Zero Touch Provisioning) error status of
the system LED. stackFwChk(5) is used to clear stack firmware version
check error status of the system LED. |
| cie1000SysutilMibConformance | 1.3.6.1.4.1.9.9.832.1.24.2 | | | |
| cie1000SysutilMibCompliances | 1.3.6.1.4.1.9.9.832.1.24.2.1 | | | |
| cie1000SysutilMibCompliance | 1.3.6.1.4.1.9.9.832.1.24.2.1.1 | | | The compliance statement for the implementation. |
| cie1000SysutilMibGroups | 1.3.6.1.4.1.9.9.832.1.24.2.2 | | | |
| cie1000SysutilCapabilitiesInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.1 | | | A collection of objects. |
| cie1000SysutilConfigSystemInfoInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.2 | | | A collection of objects. |
| cie1000SysutilConfigSystemTimeInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.3 | | | A collection of objects. |
| cie1000SysutilConfigTemperatureMonitorInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.4 | | | A collection of objects. |
| cie1000SysutilStatusCpuLoadInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.5 | | | A collection of objects. |
| cie1000SysutilStatusPowerSupplyInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.6 | | | A collection of objects. |
| cie1000SysutilStatusSystemLedInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.7 | | | A collection of objects. |
| cie1000SysutilStatusSystemUptimeInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.8 | | | A collection of objects. |
| cie1000SysutilStatusBoardInfoInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.9 | | | A collection of objects. |
| cie1000SysutilStatusTemperatureMonitorInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.10 | | | A collection of objects. |
| cie1000SysutilStatusLedStatusSystemInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.11 | | | A collection of objects. |
| cie1000SysutilStatusLedStatusPortInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.12 | | | A collection of objects. |
| cie1000SysutilControlRebootInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.13 | | | A collection of objects. |
| cie1000SysutilControlSystemLedInfoGroup | 1.3.6.1.4.1.9.9.832.1.24.2.2.14 | | | A collection of objects. |