All MIBs › ACC-HUB
Category: Hardware and Environment, Vendor: ACC/Ericsson
Description:
Manages hub port configuration on ACC/Ericsson integrated router/hub products, providing per-port enable/disable and traffic counters.
Imported Objects
From ACC-MIB
| DisplayString | |
| IfIndex | |
| RowStatus | |
| SmdsAddress | |
| accBRG | OBJECT-IDENTITY |
From ACC-SYSTEM
| accTrapLogSeqNum | OBJECT-TYPE |
From RFC1155-SMI
| OBJECT-TYPE |
What Is ACC-HUB?
ACC-HUB is a legacy ACC (Advanced Computer Communications) proprietary MIB reporting Ethernet hub port statistics on ACC access equipment. Its hub-statistics table, keyed by port/hub index, records administrative and operational status, bit-error count, and link-test result. As a hardware-status MIB it lets an administrator confirm a hub port's link-test result and bit-error count when diagnosing a flaky Ethernet connection. It is deployed on legacy ACC access equipment with Ethernet hub ports. Engineers can download the ACC-HUB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ACC-HUB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
What Can Be Monitored
- hub port bit-error count and link-test result
Supported Devices
- Legacy ACC access equipment (Ethernet hub ports)
Monitoring Examples
An administrator checks accEnetHubBitError and accEnetHubLinkTest to diagnose a hub port reporting intermittent connectivity on legacy ACC equipment.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| accEnetHub | 1.3.6.1.4.1.5.1.1.39 | |||
| accEnetHubStatTable | 1.3.6.1.4.1.5.1.1.39.1 | not-accessible | A List of Ethernet Hub Port statistics. | |
| accEnetHubStatEntry | 1.3.6.1.4.1.5.1.1.39.1.1 | not-accessible | A table entry providing information about Ethernet Hub ports. | |
| INT accEnetPortIndex | 1.3.6.1.4.1.5.1.1.39.1.1.1 | INTEGER | read-only | This is the Ethernet Physical Port starting with 1 |
| INT accEnetHubIndex | 1.3.6.1.4.1.5.1.1.39.1.1.2 | INTEGER | read-only | This is the Ethernet Hub Port index 1-8 |
| INT accEnetHubAdStatus | 1.3.6.1.4.1.5.1.1.39.1.1.3 | INTEGER | read-write | This is the current administrative status of the Ethernet Hub Port. |
| INT accEnetHubOpStatus | 1.3.6.1.4.1.5.1.1.39.1.1.4 | INTEGER | read-only | This shows the Operational State of the Ethernet Hub Port |
| INT accEnetHubBitError | 1.3.6.1.4.1.5.1.1.39.1.1.5 | INTEGER | read-only | This shows whether a bit-error has occurred |
| INT accEnetHubLinkTest | 1.3.6.1.4.1.5.1.1.39.1.1.6 | INTEGER | read-only | This shows whether a link test has occurred |
RFC description
Vendor-private MIB for ACC (American Communication Company) hub equipment management, covering port status and traffic counters.
Start monitoring ACC/Ericsson WAN access routers (legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.