CPQSTSYS-MIB

MIB Reference — IPNetwork Monitor

All MIBsCPQSTSYS-MIB

Category: Fibre Channel and Storage, Hardware and Environment, Vendor: HP/HPE

Description:

Manages HP StorageWorks storage system arrays including RAID configuration, logical volumes, and physical disk status.

Imported Objects

From CPQHOST-MIB

compaqOBJECT-IDENTITY
cpqHoTrapFlagsOBJECT-TYPE

From RFC-1212

OBJECT-TYPE

From RFC-1215

TRAP-TYPE

From RFC1155-SMI

Counter

From RFC1213-MIB

DisplayString
sysName

What Is CPQSTSYS-MIB?

CPQSTSYS-MIB is a Compaq/HP StorageWorks MIB module for managing storage system arrays, covering RAID controller configuration, logical volume definitions, and physical disk drive status on HP StorageWorks (legacy Compaq) storage array hardware. It exposes storage-hardware categories: RAID array/controller configuration, logical volume layout and state, and per-disk physical status, which together describe both the logical and physical health of a storage subsystem. Its monitoring emphasis is squarely on storage hardware status - administrators use it to detect a failed or degraded physical disk, a RAID array running in a degraded (non-optimal) state, or a logical volume that has gone offline, all of which are classic precursors to data-loss risk if not remediated. It typically works alongside the more general Compaq/HP Insight Manager health MIBs that report overall system health status alongside this array-specific detail. It is deployed on HP StorageWorks/Compaq storage arrays and the servers or SAN controllers managing them in enterprise data center environments, and loading this module into a CPQSTSYS-MIB MIB Browser session lets an administrator walk the RAID, logical volume, and physical disk tables interactively when diagnosing a storage alert.

IPNetwork Monitor allows you to monitor SNMP objects defined in CPQSTSYS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • RAID array/controller status
  • logical volume status
  • physical disk drive status

Supported Devices

  • HPE MSA 2060 (2020) — entry/midrange SAN storage array, current successor to the HP StorageWorks Modular Smart Array line

Monitoring Examples

An administrator would poll the array's logical-volume status objects to detect a volume that has dropped from an optimal to a degraded or failed state, and check per-disk physical-drive status entries to identify which specific drive triggered the condition. No specific object names were included in the source data for this module, so this description generalizes from its documented RAID/logical-volume/physical-disk scope rather than citing exact table or column names.

OIDs
OID symbolicOID numericTypeAccessDescription
NTF cpqSs2FanStatusChange1.3.6.1.4.1.232.0.8001Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
NTF cpqSsTempFailed1.3.6.1.4.1.232.0.8002Storage System temperature failure. The agent has detected that a temperature status has been set to failed. The storage system will be shutdown.
NTF cpqSsTempDegraded1.3.6.1.4.1.232.0.8003Storage System temperature degraded. The agent has detected a temperature status that has been set to degraded. The storage system's temperature is outside of the normal operating range.
NTF cpqSsTempOk1.3.6.1.4.1.232.0.8004Storage System temperature ok. The temperature status has been set to OK. The storage system's temperature has returned to normal operating range. It may be reactivated by the administrator.
NTF cpqSsSidePanelInPlace1.3.6.1.4.1.232.0.8005Storage System side panel is in place. The side panel status has been set to in place. The storage system's side panel has returned to a properly installed state.
NTF cpqSsSidePanelRemoved1.3.6.1.4.1.232.0.8006Storage System side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel.
NTF cpqSsPwrSupplyDegraded1.3.6.1.4.1.232.0.8007A storage system power supply status has been set to degraded.
NTF cpqSs3FanStatusChange1.3.6.1.4.1.232.0.8008Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
NTF cpqSs3TempFailed1.3.6.1.4.1.232.0.8009Storage System temperature failure. The agent has detected that a temperature status has been set to failed. The storage system will be shutdown. User Action: Shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
NTF cpqSs3TempDegraded1.3.6.1.4.1.232.0.8010Storage System temperature degraded. The agent has detected a temperature status that has been set to degraded. The storage system's temperature is outside of the normal operating range. User Action: Shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
NTF cpqSs3TempOk1.3.6.1.4.1.232.0.8011Storage System temperature ok. The temperature status has been set to OK. The storage system's temperature has returned to normal operating range. It may be reactivated by the administrator. User Action: None.
NTF cpqSs3SidePanelInPlace1.3.6.1.4.1.232.0.8012Storage System side panel is in place. The side panel status has been set to in place. The storage system's side panel has returned to a properly installed state. User Action: None.
NTF cpqSs3SidePanelRemoved1.3.6.1.4.1.232.0.8013Storage System side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel. User Action: Replace the storage system side panel.
NTF cpqSs3PwrSupplyDegraded1.3.6.1.4.1.232.0.8014A storage system power supply status has been set to degraded.
NTF cpqSs4PwrSupplyDegraded1.3.6.1.4.1.232.0.8015A storage system power supply status has been set to degraded. User Action: Take action to restore power or replace any failed storage system power supply.
NTF cpqSsExFanStatusChange1.3.6.1.4.1.232.0.8016Storage system fan status change. The agent has detected a change in the Fan Module Status of a storage system. The variable cpqSsFanModuleStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
NTF cpqSsExPowerSupplyStatusChange1.3.6.1.4.1.232.0.8017Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status. User Action: If the power supply status is failed, take action to restore power or replace the failed power supply.
NTF cpqSsExPowerSupplyUpsStatusChange1.3.6.1.4.1.232.0.8018Storage system power supply UPS status change. The agent has detected a change status of a UPS attached to a storage system power supply. The variable cpqSsPowerSupplyUpsStatus indicates the current status. User Action: If the UPS status is powerFailed(4) or batteryLow(5), take action to restore power to the UPS.
NTF cpqSsExTempSensorStatusChange1.3.6.1.4.1.232.0.8019Storage system temperature sensor status change. The agent has detected a change in the status of a storage system temperature sensor. The variable cpqSsTempSensorStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
NTF cpqSsEx2FanStatusChange1.3.6.1.4.1.232.0.8020Storage system fan status change. The agent has detected a change in the fan module status of a storage system. The variable cpqSsFanModuleStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
NTF cpqSsEx2PowerSupplyStatusChange1.3.6.1.4.1.232.0.8021Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status. User Action: If the power supply status is failed, take action to restore power or replace the failed power supply.
NTF cpqSsExBackplaneFanStatusChange1.3.6.1.4.1.232.0.8022Storage system fan status change. The agent has detected a change in the fan status of a storage system. The variable cpqSsBackplaneFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
NTF cpqSsExBackplaneTempStatusChange1.3.6.1.4.1.232.0.8023Storage system temperature status change. The agent has detected a change in the status of the temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
NTF cpqSsExBackplanePowerSupplyStatusChange1.3.6.1.4.1.232.0.8024Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBackplaneFtpsStatus indicates the current status. User Action: If the power supply status is degraded, take action to restore power or replace the failed power supply.
NTF cpqSsExRecoveryServerStatusChange1.3.6.1.4.1.232.0.8025Storage system recovery server option status change. The agent has detected a change in the recovery server option status of a storage system. The variable cpqSsChassisRsoStatus indicates the current status. User Action: If the RSO status is noSecondary(6) or linkDown(7), insure the secondary server is operational and all cables are connected properly. If the RSO status is secondaryRunningAuto(8) or secondaryRunningUser(9), examine the the primary server for failed components.
NTF cpqSs5FanStatusChange1.3.6.1.4.1.232.0.8026Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
NTF cpqSs5TempStatusChange1.3.6.1.4.1.232.0.8027Storage System temperature status change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
NTF cpqSs5PwrSupplyStatusChange1.3.6.1.4.1.232.0.8028Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status. User Action: If the power supply status is degraded, take action to restore power or replace the failed power supply.
NTF cpqSs6FanStatusChange1.3.6.1.4.1.232.0.8029Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
NTF cpqSs6TempStatusChange1.3.6.1.4.1.232.0.8030Storage System temperature status change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
NTF cpqSs6PwrSupplyStatusChange1.3.6.1.4.1.232.0.8031Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status. User Action: If the power supply status is degraded, take action to restore power or replace the failed power supply.
cpqSsStorageSys1.3.6.1.4.1.232.8
NTF cpqSsFanStatusChange1.3.6.1.4.1.232.8.0.1Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
cpqSsMibRev1.3.6.1.4.1.232.8.1
INT cpqSsMibRevMajor1.3.6.1.4.1.232.8.1.1INTEGERread-onlyThe Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information, correct interpretation of data may require a MIB document with the same major revision level.
INT cpqSsMibRevMinor1.3.6.1.4.1.232.8.1.2INTEGERread-onlyThe Minor Revision level. A change in the minor revision level may represent some minor additional support; no changes to any pre-existing information has occurred.
INT cpqSsMibCondition1.3.6.1.4.1.232.8.1.3INTEGERread-onlyThe overall condition (status) of the system represented by this MIB.
cpqSsDrvBox1.3.6.1.4.1.232.8.2
cpqSsDrvBoxTable1.3.6.1.4.1.232.8.2.1not-accessibleDrive Box Table.
cpqSsDrvBoxEntry1.3.6.1.4.1.232.8.2.1.1not-accessibleDrive Box Entry.
INT cpqSsBoxCntlrIndex1.3.6.1.4.1.232.8.2.1.1.1INTEGERread-onlyDrive Box Controller Index. The controller index indicates to which adapter card instance this table entry belongs.
INT cpqSsBoxBusIndex1.3.6.1.4.1.232.8.2.1.1.2INTEGERread-onlyDrive Box Bus Index. The bus index indicates to which bus instance on an adapter card this table entry belongs.
INT cpqSsBoxType1.3.6.1.4.1.232.8.2.1.1.3INTEGERread-onlyDrive Box Type. This is the type of drive box. The following types are defined: other(1) The agent does not recognize this drive storage system. proLiant(2) This is a ProLiant Storage System. proLiant2(3) This is a ProLiant-2 Storage System. proLiant2Internal(4) This is an internal ProLiant-2 Storage System that is found in some servers. proLiant2DuplexTop(5) This is the top portion of a ProLiant-2 Storage System that has dual SCSI busses which are duplexed. proLiant2DuplexBottom(6) This is the bottom portion of a ProLiant-2 Storage System that has dual SCSI busses which are duplexed. proLiant2InternalDuplexTop(7) This is the top portion of a ProLiant Server into which the internal SCSI busses are duplexed. proLiant2InternalDuplexBottom(8) This is the bottom portion of a ProLiant Server into which the internal SCSI busses are duplexed.
STR cpqSsBoxModel1.3.6.1.4.1.232.8.2.1.1.4DisplayStringread-onlyDrive Box Model. This is a description of the drive box's model. This can be used for identification purposes.
STR cpqSsBoxFWRev1.3.6.1.4.1.232.8.2.1.1.5DisplayStringread-onlyDrive Box Firmware Revision. This is the revision level of the drive box. This can be used for identification purposes.
STR cpqSsBoxVendor1.3.6.1.4.1.232.8.2.1.1.6DisplayStringread-onlyDrive Box Vendor This is the drive box's vendor name. This can be used for identification purposes.
INT cpqSsBoxFanStatus1.3.6.1.4.1.232.8.2.1.1.7INTEGERread-onlyDrive Box Fan Status. This is the current status of the fans in the drive box. This value will be one of the following: other(1) Fan monitoring is not supported by this system or it is not supported by the driver. ok(2) All fans are working normally. failed(3) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage. noFan(4) This unit does not support fan monitoring. degraded(5) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced.
INT cpqSsBoxCondition1.3.6.1.4.1.232.8.2.1.1.8INTEGERread-onlySCSI Drive Box Condition. This is the overall condition of the drive box. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system is degraded. You need to check the temperature status or power supply status of this storage system. Additionally, if the side panel for the storage system is removed, the air flow changes could result in improper cooling of the drives and affect the temperature status. failed(4) The storage system has failed.
INT cpqSsBoxTempStatus1.3.6.1.4.1.232.8.2.1.1.9INTEGERread-onlyThe temperature of the drive system. This value will be one of the following: other(1) Temperature monitoring is not supported by this system or it is not supported by the driver. ok(2) The temperature is within normal operating range. degraded(3) The temperature is outside of normal operating range. failed(4) The temperature could permanently damage the system. The storage system will automatically shutdown if this condition is detected. noTemp(5) This unit does not support temperature monitoring.
INT cpqSsBoxSidePanelStatus1.3.6.1.4.1.232.8.2.1.1.10INTEGERread-onlyDrive Box Side Panel Status. This value will be one of the following: other(1) The agent does not recognize the status. You may need to upgrade your software. sidePanelInPlace(2) The side panel is properly installed on the storage system. sidePanelRemoved(3) The side panel is not properly installed on the storage system. noSidePanelStatus(4) This unit does not support side panel status monitoring.
INT cpqSsBoxFltTolPwrSupplyStatus1.3.6.1.4.1.232.8.2.1.1.11INTEGERread-onlyThis value specifies the overall status of the fault tolerant power supply sub-system in a drive box. This value will be one of the following: other(1) The power supply status cannot be determined. ok(2) There are no detected power supply failures. degraded(3) One of the power supply units in a fault tolerant power supply has failed. failed(4) No failure conditions can currently be determined. noFltTolPower(5) This unit does not support fault tolerant power supply monitoring.
INT cpqSsBoxBackPlaneVersion1.3.6.1.4.1.232.8.2.1.1.12INTEGERread-onlyDrive Box Back Plane Version. This is the version of the drive box back plane. The following types are defined: other(1) The agent does not recognize this drive storage system back plane. proLiant(2) This is a ProLiant Storage System. proLiant2(3) This is a ProLiant-2 Storage System. proLiant3(4) This is a ProLiant-3 Storage System. proLiant4(5) This is a 4th generation Proliant Storage System. proLiant5(6) This is a 5th generation ProLiant Storage System.
INT cpqSsBoxTotalBays1.3.6.1.4.1.232.8.2.1.1.13INTEGERread-onlyDrive Box Total Bays. This is the total number of bays in this storage system.
INT cpqSsBoxPlacement1.3.6.1.4.1.232.8.2.1.1.14INTEGERread-onlyDrive Box Placement. The following values are defined: other(1) The agent is unable to determine if this storage system is located internal or external to the system chassis. internal(2) The storage system is located in the system chassis. external(3) The storage system is located outside the system chassis in an expansion box.
INT cpqSsBoxDuplexOption1.3.6.1.4.1.232.8.2.1.1.15INTEGERread-onlyDrive Box Duplex Option. The following values are defined: other(1) The agent is unable to determine if this storage system is duplexed. notDuplexed(2) This storage system is not duplexed. duplexTop(3) This is the top portion of a duplexed storage system. duplexBottom(4) This is the bottom portion of a duplexed storage system.
INT cpqSsBoxBoardRevision1.3.6.1.4.1.232.8.2.1.1.16INTEGERread-onlyDrive Box Board Revision. This is the board revision of this storage system backplane.
STR cpqSsBoxSerialNumber1.3.6.1.4.1.232.8.2.1.1.17DisplayStringread-onlyDrive Box Serial Number. This is the drive box's serial number which is normally display on the front panel. This can be used for identification purposes.
STR cpqSsBoxCntlrHwLocation1.3.6.1.4.1.232.8.2.1.1.18DisplayStringread-onlyA text description of the hardware location of the controller to which this box is attached. A NULL string indicates that the hardware location could not be determined or is irrelevant.
INT cpqSsBoxBackplaneSpeed1.3.6.1.4.1.232.8.2.1.1.19INTEGERread-onlyDrive Box Backplane Speed. The following values are defined: other(1) The agent is unable to determine the backplane speed for this storage system. ultra3(2) This storage system is capable of Ultra3 speeds. ultra320(3) This storage system is capable of Ultra320 speeds.
INT cpqSsBoxConnectionType1.3.6.1.4.1.232.8.2.1.1.20INTEGERread-onlyDrive Box Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this storage system. scsiAttached(2) This storage system is attached to the host via SCSI. sasAttached(3) This storage system is attached to the host via SAS.
STR cpqSsBoxHostConnector1.3.6.1.4.1.232.8.2.1.1.21DisplayStringread-onlyDrive Box Host Connector. This is the host connector to which the drive box is attached. If the host connector cannot be determined, the agent will return a NULL string.
INT cpqSsBoxBoxOnConnector1.3.6.1.4.1.232.8.2.1.1.22INTEGERread-onlyDrive Box, Box on Connector. The box on connector indicates which box instance this table entry belongs. The instances start at one and increment for each box attached to a connector. If the value cannot be determined or does not apply, -1 is returned.
STR cpqSsBoxLocationString1.3.6.1.4.1.232.8.2.1.1.23DisplayStringread-onlyDrive Box Location String. This string describes the location of the drive box in relation to the controller to which it is attached. If the location string cannot be determined, the agent will return a NULL string.
cpqSsBoxExtended1.3.6.1.4.1.232.8.2.2
cpqSsChassisTable1.3.6.1.4.1.232.8.2.2.1not-accessibleStorage System Chassis Table.
cpqSsChassisEntry1.3.6.1.4.1.232.8.2.2.1.1not-accessibleStorage System Chassis Entry.
INT cpqSsChassisIndex1.3.6.1.4.1.232.8.2.2.1.1.1INTEGERread-onlyStorage System Chassis Index. The chassis index uniquely identifies a storage system chassis.
INT cpqSsChassisConnectionType1.3.6.1.4.1.232.8.2.2.1.1.2INTEGERread-onlyStorage System Chassis Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this chassis. fibreAttached(2) This chassis is attached to the server via Fibre Channel. scsiAttached(3) This chassis is attached to the server via SCSI. iScsiAttached(4) This chassis is attached to the server via iSCSI. sasAttached(5) This chassis is attached to the server via SAS.
STR cpqSsChassisSerialNumber1.3.6.1.4.1.232.8.2.2.1.1.3DisplayStringread-onlyStorage System Chassis Serial Number. This is the storage system chassis's serial number which is normally displayed on the front panel. This can be used for identification purposes.
STR cpqSsChassisName1.3.6.1.4.1.232.8.2.2.1.1.4DisplayStringread-onlyStorage System Chassis Name. This is a user defined name for this storage system chassis.
STR cpqSsChassisSystemBoardSerNum1.3.6.1.4.1.232.8.2.2.1.1.5DisplayStringread-onlyStorage System Chassis System Controller Board Serial Number. This is the system controller board's serial number. This can be used for identification purposes.
STR cpqSsChassisSystemBoardRev1.3.6.1.4.1.232.8.2.2.1.1.6DisplayStringread-onlyStorage System Chassis System Controller Board Revision. This is the system controller board revision.
STR cpqSsChassisPowerBoardSerNum1.3.6.1.4.1.232.8.2.2.1.1.7DisplayStringread-onlyStorage System Chassis Power Backplane Board Serial Number. This is the power backplane board's serial number. This can be used for identification purposes.
STR cpqSsChassisPowerBoardRev1.3.6.1.4.1.232.8.2.2.1.1.8DisplayStringread-onlyStorage System Chassis Power Backplane Board Revision. This is the power backplane board revision.
STR cpqSsChassisScsiBoardSerNum1.3.6.1.4.1.232.8.2.2.1.1.9DisplayStringread-onlyStorage System Chassis SCSI Drive Backplane Board Serial Number. This is the SCSI drive backplane board's serial number. This can be used for identification purposes.
STR cpqSsChassisScsiBoardRev1.3.6.1.4.1.232.8.2.2.1.1.10DisplayStringread-onlyStorage System Chassis SCSI Drive Backplane Board Revision. This is the SCSI drive backplane board revision.
INT cpqSsChassisOverallCondition1.3.6.1.4.1.232.8.2.2.1.1.11INTEGERread-onlyStorage System Chassis Overall Condition. This is the condition of the storage system chassis and all of its components. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system chassis is degraded. failed(4) The storage system chassis is failed.
INT cpqSsChassisPowerSupplyCondition1.3.6.1.4.1.232.8.2.2.1.1.12INTEGERread-onlyStorage System Power Supply Condition. This is the aggregate condition of all power supplies in the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All power supplies are operating normally. degraded(3) At least one power supply is degraded or failed. failed(4) All power supplies are failed.
INT cpqSsChassisFanCondition1.3.6.1.4.1.232.8.2.2.1.1.13INTEGERread-onlyStorage System Fan Condition. This is the aggregate condition of all fan modules in the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All fan modules are operating normally. degraded(3) At least one fan module is degraded. failed(4) At least one fan module is failed.
INT cpqSsChassisTemperatureCondition1.3.6.1.4.1.232.8.2.2.1.1.14INTEGERread-onlyStorage System Temperature Condition. This is the aggregate condition of all the temperatur sensors in the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All temperature sensors are reading within normal limits. degraded(3) At least one temperature sensor is reading degraded. failed(4) At least one temperature sensor is reading failed.
INT cpqSsChassisFcaCntlrCondition1.3.6.1.4.1.232.8.2.2.1.1.15INTEGERread-onlyStorage System Fibre Channel Array Controller Condition. This is the aggregate condition of all Fibre Channel Array controllers in the storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All Fibre Channel Array Controllers are operating normally. degraded(3) At least one Fibre Channel Array Controller is degraded or failed. failed(4) All Fibre Channel Array Controllers are failed.
INT cpqSsChassisFcaLogicalDriveCondition1.3.6.1.4.1.232.8.2.2.1.1.16INTEGERread-onlyStorage System Fibre Channel Array Logical Drive Condition. This is the aggregate condition of all Fibre Channel Array Logical Drives in this storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All Fibre Channel Array Controllers Logical Drives are operating normally. degraded(3) At least one Fibre Channel Array Controller Logical Drive is degraded. failed(4) At least one Fibre Channel Array Controller Logical Drive is failed.
INT cpqSsChassisFcaPhysDrvCondition1.3.6.1.4.1.232.8.2.2.1.1.17INTEGERread-onlyStorage System Fibre Channel Array Physical Drive Condition. This is the aggregate condition of all Fibre Channel Array Physical Drives in this storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All Fibre Channel Array Controllers Physical Drives are operating normally. degraded(3) At least one Fibre Channel Array Controller Physical Drive is degraded. failed(4) At least one Fibre Channel Array Controller Physical Drive is failed.
INT cpqSsChassisTime1.3.6.1.4.1.232.8.2.2.1.1.18INTEGERread-onlyStorage System Chassis Time. This is the storage system chassis's time in tenths of seconds. If the chassis time is not supported, the agent will return 0.
INT cpqSsChassisModel1.3.6.1.4.1.232.8.2.2.1.1.19INTEGERread-onlyStorage System Chassis Model. The following values are defined: other(1) The agent is unable to determine the model of this chassis. ra4x00(2) Compaq StorageWorks RAID Array 4000/4100. msa1000(3) Compaq StorageWorks Modular Smart Array 1000. smartArrayClusterStorage(4) HP StorageWorks Modular Smart Array 500 (Formerly Smart Array Cluster Storage). enterpriseModularArray(5) Compaq StorageWorks Enterprise/Modular RAID Array. enterpriseVirtualArray(6) Compaq StorageWorks Enterprise Virtual Array. msa500G2(7) HP StorageWorks Modular Smart Array 500 G2. msa20(8) HP StorageWorks Modular Smart Array 20. msa1500cs(9) HP StorageWorks Modular Smart Array 1500 CS. msa1510i(10) HP StorageWorks Modular Smart Array 1510i. Reserved(11) Reserved(12)
INT cpqSsChassisBackplaneCondition1.3.6.1.4.1.232.8.2.2.1.1.20INTEGERread-onlyStorage System Backplane Condition. This is the aggregate condition of all the backplanes for the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All backplanes are operating normally. degraded(3) At least one storage system is degraded. failed(4) At least one storage system is failed.
INT cpqSsChassisFcaTapeDrvCondition1.3.6.1.4.1.232.8.2.2.1.1.21INTEGERread-onlyStorage System Array Tape Drive Condition. This is the aggregate condition of all tape drives in this storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All tape drives are operating normally. degraded(3) At least one tape drive is degraded. failed(4) At least one tape drive is failed.
INT cpqSsChassisRsoStatus1.3.6.1.4.1.232.8.2.2.1.1.22INTEGERread-onlyStorage System Chassis Recovery Server Option Status. The following values are defined: other(1) The recovery server option status cannot be determined for this storage system. notSupported(2) The recovery server option is not supported for this storage system. notConfigured(3) The recovery server option is supported, but is not configured on this storage system. disabled(4) The recovery server option is configured as primary, but has been disabled by software. daemonDownDisabled(5) The recovery server option operating system daemon is no longer running. The last status of RSO was disabled(4). ok(6) The recovery server option is configured as primary and everything is working correctly. daemonDownActive(7) The recovery server option operating system daemon is no longer running. The last status of RSO was ok(6). noSecondary(8) The recovery server option is configured as primary, but communication with the standby server has not been established. daemonDownNoSecondary(9) The recovery server option operating system daemon is no longer running. The last status of RSO was noSecondary(8). linkDown(10) The recovery server option is configured as primary, but communication with the standby server has failed. daemonDownLinkDown(11) The recovery server option operating system daemon is no longer running. The last status of RSO was linkDown(10). secondaryRunningAuto(12) The recovery server option is configured and the standby server is running. The secondary server assumed control after communication with the primary server failed. secondaryRunningUser(13) The recovery server option is configured and the standby server is running. A user forced the secondary server to assume control. evTimeoutError(14) The recovery server option environment variable cannot be accessed.
INT cpqSsChassisRsoCondition1.3.6.1.4.1.232.8.2.2.1.1.23INTEGERread-onlyStorage System Chassis Recovery Server Option Condition. This is the condition of the recovery server option. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The recovery server option is operating normally. No user action is required. degraded(3) The recovery server option is degraded. failed(4) The recovery server option is failed.
INT cpqSsChassisScsiIoModuleType1.3.6.1.4.1.232.8.2.2.1.1.24INTEGERread-onlyStorage System Chassis SCSI I/O Module Type. The following values are defined: other(1) The agent does not recognize SCSI I/O module type. You may need to upgrade your software. io2port(2) A 2-Port Ultra3 SCSI I/O Module is installed. io4portUpgradeFirmware(3) A 4-Port Shared Storage Module for Smart Array Cluster Storage is installed, but the current controller firmware does not support it. Upgrade your controller firmware. io4port(4) A 4-Port Shared Storage Module for Smart Array Cluster Storage is installed. io2port320(5) A 2-Port Ultra320 SCSI I/O Module is installed. io4port320(6) A 4-Port Ultra320 SCSI I/O Module is installed. io1port320(7) A 1-Port Ultra320 SCSI I/O Module is installed.
INT cpqSsChassisPreferredPathMode1.3.6.1.4.1.232.8.2.2.1.1.25INTEGERread-onlyArray Controller Preferred Path Mode. This is the storage system active/active preferred path mode. The following values are valid: other (1) Indicates that the agent does not recognize the preferred path mode of the storage system. You may need to upgrade the agent. notActiveActive (2) The storage system is not configured as active/active. automatic (3) The storage system automatically selects the preferred path for each logical drive based on host I/O patterns. manual (4) The preferred path for each logical drive is manually configured by the storage system administrator.
STR cpqSsChassisProductId1.3.6.1.4.1.232.8.2.2.1.1.26DisplayStringread-onlyStorage System Chassis Product Identifier. This is the storage system chassis's product identifier. This can be used for identification purposes. If the product identifier can not be determined, the agent will return a NULL string.
cpqSsIoSlotTable1.3.6.1.4.1.232.8.2.2.2not-accessibleStorage System I/O Slot Table.
cpqSsIoSlotEntry1.3.6.1.4.1.232.8.2.2.2.1not-accessibleStorage System I/O Slot Entry.
INT cpqSsIoSlotChassisIndex1.3.6.1.4.1.232.8.2.2.2.1.1INTEGERread-onlyStorage System I/O Slot Chassis Index. The chassis index uniquely identifies a storage system chassis.
INT cpqSsIoSlotIndex1.3.6.1.4.1.232.8.2.2.2.1.2INTEGERread-onlyStorage System I/O Slot Index. This index uniquely identifies a storage system I/O Slot.
INT cpqSsIoSlotControllerType1.3.6.1.4.1.232.8.2.2.2.1.3INTEGERread-onlyStorage System I/O Slot Controller Type. The following values are defined: other(1) The agent is unable to determine if anything is installed in this storage system I/O slot. notInstalled(2) Nothing is installed in this storage system I/O slot. unknownBoardInstalled(3) An unknown controller is installed in this storage system I/O slot. fibreArray(4) A Fibre Channel Array controller is installed in this storage system I/O slot. scsiArray(5) A SCSI Array controller is installed in this storage system I/O slot. noSlot(6) The slot does not exist on this chassis. iScsiArray(7) An iSCSI Array controller is installed in this storage system I/O slot. sasArray(8) A SAS Array controller is installed in this storage system I/O slot.
cpqSsPowerSupplyTable1.3.6.1.4.1.232.8.2.2.3not-accessibleStorage System Power Supply Table.
cpqSsPowerSupplyEntry1.3.6.1.4.1.232.8.2.2.3.1not-accessibleStorage System Power Supply Entry.
INT cpqSsPowerSupplyChassisIndex1.3.6.1.4.1.232.8.2.2.3.1.1INTEGERread-onlyStorage System Power Supply Chassis Index. The chassis index uniquely identifies a storage system chassis.
INT cpqSsPowerSupplyIndex1.3.6.1.4.1.232.8.2.2.3.1.2INTEGERread-onlyStorage System Power Supply Bay. This index uniquely identifies a power supply bay.
INT cpqSsPowerSupplyBay1.3.6.1.4.1.232.8.2.2.3.1.3INTEGERread-onlyStorage System Power Supply Bay. The following values are defined: other(1) The agent does not recognize the bay. You may need to upgrade your software. powerBay1(2) The power supply is installed in the first power supply bay. powerBay2(3) The power supply is installed in the second power supply bay. composite(4) The power supply information is a composite of all power supplies in the storage system.
INT cpqSsPowerSupplyStatus1.3.6.1.4.1.232.8.2.2.3.1.4INTEGERread-onlyStorage System Power Supply Status. The following values are defined: other(1) The agent is unable to determine if this storage system power supply bay is occupied. notInstalled(2) Nothing is installed in this power supply bay. ok(3) A power supply is installed and operating normally. failed(4) A power supply is installed and is no longer operating. Replace the power supply. degraded(5) For composite power supplies, this indicates that at least one power supply has failed or lost power.
INT cpqSsPowerSupplyUpsStatus1.3.6.1.4.1.232.8.2.2.3.1.5INTEGERread-onlyStorage System Power Supply Uninterruptible Power Supply (UPS) Status. The following values are defined: other(1) The agent is unable to determine if this power supply is attached to an Uninterruptible Power Supply (UPS). noUps(2) No UPS is attached to the power supply. ok(3) A UPS is attached to the power supply and is operating normally. powerFailed(4) A UPS is attached to the power supply and the AC power has failed. batteryLow(5) A UPS is attached to the power supply, the AC power has failed and the UPS battery is low.
INT cpqSsPowerSupplyCondition1.3.6.1.4.1.232.8.2.2.3.1.6INTEGERread-onlyStorage System Power Supply Condition. This is the condition of the storage system chassis and all of its components. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The power supply is operating normally. No user action is required. degraded(3) The power supply is degraded. You need to check the power supply or its attached UPS for problems. failed(4) The power supply has failed.
STR cpqSsPowerSupplySerialNumber1.3.6.1.4.1.232.8.2.2.3.1.7DisplayStringread-onlyStorage System Power Supply Serial Number. This is the power supply's serial number. This can be used for identification purposes. If the serial number is not supported, the agent will return a NULL string.
STR cpqSsPowerSupplyBoardRevision1.3.6.1.4.1.232.8.2.2.3.1.8DisplayStringread-onlyStorage System Power Supply Board Revision. This is the power supply board revision. If the board revision is not supported, the agent will return a NULL string.
STR cpqSsPowerSupplyFirmwareRevision1.3.6.1.4.1.232.8.2.2.3.1.9DisplayStringread-onlyStorage System Power Supply Firmware Revision. This is the power supply firmware revision. If the firmware revision is not supported, the agent will return a NULL string.
cpqSsFanModuleTable1.3.6.1.4.1.232.8.2.2.4not-accessibleStorage System Fan Module Table.
cpqSsFanModuleEntry1.3.6.1.4.1.232.8.2.2.4.1not-accessibleStorage System Fan Module Entry.
INT cpqSsFanModuleChassisIndex1.3.6.1.4.1.232.8.2.2.4.1.1INTEGERread-onlyStorage System Fan Module Chassis Index. The chassis index uniquely identifies a storage system chassis.
INT cpqSsFanModuleIndex1.3.6.1.4.1.232.8.2.2.4.1.2INTEGERread-onlyStorage System Fan Module Index. This index uniquely identifies a storage system fan module.
INT cpqSsFanModuleStatus1.3.6.1.4.1.232.8.2.2.4.1.3INTEGERread-onlyStorage System Fan Module Status. The following values are defined: other(1) The agent is unable to determine if this storage system fan module is installed. notInstalled(3) The fan module is not installed. ok(2) The fan module is installed and operating normally. degraded(4) The fan module degraded. failed(5) The fan module is failed. Replace the fan module.
INT cpqSsFanModuleCondition1.3.6.1.4.1.232.8.2.2.4.1.4INTEGERread-onlyStorage System Fan Module Condition. This is the condition of the storage system fan module. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The fan module is operating normally. No user action is required. degraded(3) The fan module is degraded. You need to check the fan module for problems. failed(4) The fan module has failed. Replace the fan module.
INT cpqSsFanModuleLocation1.3.6.1.4.1.232.8.2.2.4.1.5INTEGERread-onlyStorage System Fan Module Location. The following values are defined: other(1) The agent is unable to determine the location of this storage system fan module. fanBay(2) This fan module is installed in the first fan bay. composite(3) The fan information is a composite of all fans in the storage system. fanBay2(4) This fan module is installed in the second fan bay.
STR cpqSsFanModuleSerialNumber1.3.6.1.4.1.232.8.2.2.4.1.6DisplayStringread-onlyStorage System Fan Module Serial Number. This is the fan module's serial number. This can be used for identification purposes.
STR cpqSsFanModuleBoardRevision1.3.6.1.4.1.232.8.2.2.4.1.7DisplayStringread-onlyStorage System Fan Module Board Revision. This is the fan module board revision.
cpqSsTempSensorTable1.3.6.1.4.1.232.8.2.2.5not-accessibleStorage System Temperature Sensor Table.
cpqSsTempSensorEntry1.3.6.1.4.1.232.8.2.2.5.1not-accessibleStorage System Temperature Sensor Entry.
INT cpqSsTempSensorChassisIndex1.3.6.1.4.1.232.8.2.2.5.1.1INTEGERread-onlyStorage System Temperature Sensor Chassis Index. The chassis index uniquely identifies a storage system chassis.
INT cpqSsTempSensorIndex1.3.6.1.4.1.232.8.2.2.5.1.2INTEGERread-onlyStorage System Temperature Sensor Index. This index uniquely identifies a temperature sensor.
INT cpqSsTempSensorStatus1.3.6.1.4.1.232.8.2.2.5.1.3INTEGERread-onlyStorage System Temperature Sensor Status. The following values are defined: other(1) The agent is unable to determine if the storage system temperature sensor status. ok(2) The temperature is OK. degraded(3) The temperature is degraded. failed(4) The temperature is failed.
INT cpqSsTempSensorCondition1.3.6.1.4.1.232.8.2.2.5.1.4INTEGERread-onlyStorage System Fan Module Condition. This is the condition of the storage system temperature sensor. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The temperature is within normal operating range. No user action is required. degraded(3) The temperature is outside of normal operating range. failed(4) The temperature could permanently damage the system. The storage system will automatically shutdown if this condition is detected.
INT cpqSsTempSensorLocation1.3.6.1.4.1.232.8.2.2.5.1.5INTEGERread-onlyStorage System Fan Module Location. The following values are defined: other(1) The agent is unable to determine the location of this storage system temperature sensor. fanBay(2) This temperature sensor is located on the fan module in the fan bay. backplane(3) This temperature is located on the SCSI drive backplane.
INT cpqSsTempSensorCurrentValue1.3.6.1.4.1.232.8.2.2.5.1.6INTEGERread-onlyStorage System Temperature Sensor Current Value. The current value of the temperature sensor in degrees Celsius.
INT cpqSsTempSensorLimitValue1.3.6.1.4.1.232.8.2.2.5.1.7INTEGERread-onlyStorage System Temperature Sensor Limit Value. The limit value of the temperature sensor in degrees Celsius.
INT cpqSsTempSensorHysteresisValue1.3.6.1.4.1.232.8.2.2.5.1.8INTEGERread-onlyStorage System Temperature Sensor Hysteresis Value. The hysteresis value of the temperature sensor in degrees Celsius.
cpqSsBackplaneTable1.3.6.1.4.1.232.8.2.2.6not-accessibleStorage System SCSI Backplane Table.
cpqSsBackplaneEntry1.3.6.1.4.1.232.8.2.2.6.1not-accessibleStorage System SCSI Backplane Entry.
INT cpqSsBackplaneChassisIndex1.3.6.1.4.1.232.8.2.2.6.1.1INTEGERread-onlyStorage System Backplane Chassis Index. The chassis index uniquely identifies a storage system chassis.
INT cpqSsBackplaneIndex1.3.6.1.4.1.232.8.2.2.6.1.2INTEGERread-onlyStorage System Backplane Index. This index uniquely identifies a storage system backplane.
STR cpqSsBackplaneFWRev1.3.6.1.4.1.232.8.2.2.6.1.3DisplayStringread-onlyStorage System Backplane Firmware Revision. This is the revision level of storage system backplane.
INT cpqSsBackplaneDriveBays1.3.6.1.4.1.232.8.2.2.6.1.4INTEGERread-onlyStorage System Backplane Drive Bays. This is the number of bays on this storage system backplane.
INT cpqSsBackplaneDuplexOption1.3.6.1.4.1.232.8.2.2.6.1.5INTEGERread-onlyStorage System Backplane Duplex Option. The following values are defined: other (1) The agent is unable to determine if this storage system is duplexed. notDuplexed(2) This storage system is not duplexed. duplexTop(3) This is the top portion of a duplexed storage system. duplexBottom(4) This is the bottom portion of a duplexed storage system.
INT cpqSsBackplaneCondition1.3.6.1.4.1.232.8.2.2.6.1.6INTEGERread-onlyStorage System Backplane Condition. This is the overall condition of the backplane. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system is degraded. You need to check the temperature status or power supply status of this storage system. failed(4) The storage system has failed.
INT cpqSsBackplaneVersion1.3.6.1.4.1.232.8.2.2.6.1.7INTEGERread-onlyStorage System Backplane Version. This is the version of the drive box back plane.
STR cpqSsBackplaneVendor1.3.6.1.4.1.232.8.2.2.6.1.8DisplayStringread-onlyStorage System Backplane Vendor This is the storage box's vendor name. This can be used for identification purposes.
STR cpqSsBackplaneModel1.3.6.1.4.1.232.8.2.2.6.1.9DisplayStringread-onlyStorage System Backplane Model. This is a description of the storage system's model. This can be used for identification purposes.
INT cpqSsBackplaneFanStatus1.3.6.1.4.1.232.8.2.2.6.1.10INTEGERread-onlyStorage System Backplane Fan Status. This is the current status of the fans in the storage system. This value will be one of the following: other(1) The agent is unable to determine if this storage system has fan monitoring. notInstalled(2) This unit does not support fan monitoring. ok(3) All fans are working normally. degraded(4) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced. failed(5) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage. notSupported(6) The storage system does not support reporting fan status through this backplane. The fan status is reported through the first backplane on this storage system. degraded-Fan1Failed(7) Fan 1 has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced. degraded-Fan2Failed(8) Fan 2 has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced.
INT cpqSsBackplaneTempStatus1.3.6.1.4.1.232.8.2.2.6.1.11INTEGERread-onlyStorage System Backplane Fan Status. This value will be one of the following: other(1) The agent is unable to determine if this storage system has temperature monitoring. noTemp(2) This unit does not support temperature monitoring. ok(3) The temperature is within normal operating range. degraded(4) The temperature is outside of normal operating range. failed(5) The temperature could permanently damage the system. notSupported(6) The storage system does not support reporting temperature status through this backplane. The temperature status is reported through the first backplane on this storage system.
INT cpqSsBackplaneFtpsStatus1.3.6.1.4.1.232.8.2.2.6.1.12INTEGERread-onlyStorage System Backplane Fault Tolerant Power Supply Status. This value specifies the overall status of the redundant power supply in a drive box. This value will be one of the following: other(1) The agent is unable to determine if this storage system has redundant power supplies. noFltTolPower(2) This unit does not have a redundant supply. ok(3) There are no detected power supply failures. degraded(4) One of the power supply units has failed. failed(5) All of the power supplies have failed. A status of failed can not currently be determined. notSupported(6) The storage system does not support reporting fault tolerant power supply status through this backplane. The fault tolerant power supply status is reported through the first backplane on this storage system. noFltTolPower-Bay1Missing(7), This unit does not have a redundant supply. The power supply in bay 1 is missing. noFltTolPower-Bay2Missing(8) This unit does not have a redundant supply. The power supply in bay 2 is missing.
STR cpqSsBackplaneSerialNumber1.3.6.1.4.1.232.8.2.2.6.1.13DisplayStringread-onlyStorage System Backplane Serial Number. This is the storage system backplane serial number which is normally displayed on the front bezel. This can be used for identification purposes.
INT cpqSsBackplanePlacement1.3.6.1.4.1.232.8.2.2.6.1.14INTEGERread-onlyStorage System Backplane Placement. The following values are defined: other(1) The agent is unable to determine if this storage system is located internal or external to the system chassis. internal(2) The storage system is located in the system chassis. external(3) The storage system is located outside the system chassis in an expansion box.
INT cpqSsBackplaneBoardRevision1.3.6.1.4.1.232.8.2.2.6.1.15INTEGERread-onlyStorage System Backplane Board Revision. This is the board revision of this storage system backplane.
INT cpqSsBackplaneSpeed1.3.6.1.4.1.232.8.2.2.6.1.16INTEGERread-onlyStorage System Backplane Speed. The following values are defined: other(1) The agent is unable to determine the backplane speed for this storage system. ultra3(2) This storage system is capable of Ultra3 speeds. ultra320(3) This storage system is capable of Ultra320 speeds. sata(4) This storage system is capable of SATA speeds.
INT cpqSsBackplaneConnectionType1.3.6.1.4.1.232.8.2.2.6.1.17INTEGERread-onlyBacklane Box Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this backplane. scsiAttached(2) This backplane is attached to the host via SCSI. sasAttached(3) This backplane is attached to the host via SAS.
STR cpqSsBackplaneConnector1.3.6.1.4.1.232.8.2.2.6.1.18DisplayStringread-onlyBackplane Connector. This is the connector to which the backplane is attached. If the backplane connector cannot be determined, the agent will return a NULL string.
INT cpqSsBackplaneOnConnector1.3.6.1.4.1.232.8.2.2.6.1.19INTEGERread-onlyBackplane on Connector. The backplane on connector indicates to which backplane instance this table entry belongs. The instances start at one and increment for each backplane attached to a connector.
STR cpqSsBackplaneLocationString1.3.6.1.4.1.232.8.2.2.6.1.20DisplayStringread-onlyBackplane Location String. This string describes the location of the backplane in relation to the controller to which it is attached. If the location string cannot be determined, the agent will return a NULL string.
cpqSsFibreAttachmentTable1.3.6.1.4.1.232.8.2.2.7not-accessibleStorage System Fibre Attachment Table.
cpqSsFibreAttachmentEntry1.3.6.1.4.1.232.8.2.2.7.1not-accessibleStorage System Fibre Attachment Entry.
INT cpqSsFibreAttachmentIndex1.3.6.1.4.1.232.8.2.2.7.1.1INTEGERread-onlyStorage System Fibre Attachment Index. The index uniquely identifies a Fibre Attachment association entry.
INT cpqSsFibreAttachmentHostControllerIndex1.3.6.1.4.1.232.8.2.2.7.1.2INTEGERread-onlyStorage System Fibre Attachment Host Controller Index. The host controller index indicates which host controller is associated with this entry. This is equal to cpqFcaHostCntlrIndex, from the Fibre Channel Host Controller Table.
INT cpqSsFibreAttachmentHostControllerPort1.3.6.1.4.1.232.8.2.2.7.1.3INTEGERread-onlyStorage System Fibre Attachment Host Controller Port. This is the Fibre port number of the host controller. For each host controller, the port number starts at 1 and increments for each port. This is currently set to 1.
INT cpqSsFibreAttachmentDeviceType1.3.6.1.4.1.232.8.2.2.7.1.4INTEGERread-onlyStorage System Fibre Attachment Device Type. This is the type of device associated with this entry. The following values are defined: other(1) The agent is unable to determine if the type of this device. storageBox(2) The device is a Fibre attached storage system. tapeController(3) The device is a Fibre attached tape controller. fibreChannelSwitch(4) The device is a Fibre channel switch.
INT cpqSsFibreAttachmentDeviceIndex1.3.6.1.4.1.232.8.2.2.7.1.5INTEGERread-onlyStorage System Fibre Attachment Device Index. The is the index for the Fibre attached device. For a Fibre attached storage system, this is equal to cpqSsChassisIndex from the Storage System Chassis Table. For a Fibre attached tape controller, this is equal to cpqFcTapeCntlrIndex from the Fibre Channel Tape Controller Table. For a Fibre channel switch, this is equal to cpqFcSwitchIndex from the Fibre Channel Switch Table.
INT cpqSsFibreAttachmentDevicePort1.3.6.1.4.1.232.8.2.2.7.1.6INTEGERread-onlyStorage System Fibre Attachment Device Port. This is the Fibre port on a device. For a Fibre attached storage system, this is equal to cpqFcaCntlrBoxIoSlot from the Fibre Channel Array Controller Table. For a Fibre attached tape controller, this is currently set to 1. For a Fibre channel switch, this is currently set to 1.
cpqSsScsiAttachmentTable1.3.6.1.4.1.232.8.2.2.8not-accessibleStorage System SCSI Attachment Table.
cpqSsScsiAttachmentEntry1.3.6.1.4.1.232.8.2.2.8.1not-accessibleStorage System SCSI Attachment Entry.
INT cpqSsScsiAttachmentIndex1.3.6.1.4.1.232.8.2.2.8.1.1INTEGERread-onlyStorage System SCSI Attachment Index. The index uniquely identifies a SCSI Attachment association entry.
INT cpqSsScsiAttachmentControllerIndex1.3.6.1.4.1.232.8.2.2.8.1.2INTEGERread-onlyStorage System SCSI Attachment Controller Index. The controller index indicates which internal array controller is associated with this entry. This is equal to cpqDaCntlrIndex, from the Array Controller Table.
INT cpqSsScsiAttachmentControllerPort1.3.6.1.4.1.232.8.2.2.8.1.3INTEGERread-onlyStorage System SCSI Attachment Controller Port. The controller port indicates which SCSI port of an internal controller is associated with this entry.
INT cpqSsScsiAttachmentControllerTarget1.3.6.1.4.1.232.8.2.2.8.1.4INTEGERread-onlyStorage System SCSI Attachment Controller Target. The controller target indicates which SCSI target is associated with this entry.
INT cpqSsScsiAttachmentControllerLun1.3.6.1.4.1.232.8.2.2.8.1.5INTEGERread-onlyStorage System SCSI Attachment Controller Lun. The controller Lun indicates which SCSI Lun is associated with this entry.
INT cpqSsScsiAttachmentChassisIndex1.3.6.1.4.1.232.8.2.2.8.1.6INTEGERread-onlyStorage System SCSI Attachment Chassis Index. The is the index for the SCSI attached storage system. This is equal to cpqSsChassisIndex from the Storage System Chassis Table.
INT cpqSsScsiAttachmentChassisIoSlot1.3.6.1.4.1.232.8.2.2.8.1.7INTEGERread-onlyStorage System SCSI Attachment Chassis I/O Slot. This is the I/O slot in the SCSI attached storage system. This is equal to cpqFcaCntlrBoxIoSlot from the Fibre Channel Array Controller Table.
INT cpqSsScsiAttachmentPathStatus1.3.6.1.4.1.232.8.2.2.8.1.8INTEGERread-onlyStorage System SCSI Attachment Path Status. This is the status of this path to the chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The path is operating normally. offline(3) The path is offline.
INT cpqSsScsiAttachmentPathCondition1.3.6.1.4.1.232.8.2.2.8.1.9INTEGERread-onlyStorage System SCSI Attachment Path Condition. This is the condition of this path to the chassis.
cpqSsDrvBoxPathTable1.3.6.1.4.1.232.8.2.3not-accessibleDrive Box Access Path Table.
cpqSsDrvBoxPathEntry1.3.6.1.4.1.232.8.2.3.1not-accessibleDrive Box Access Path Entry.
INT cpqSsDrvBoxPathCntlrIndex1.3.6.1.4.1.232.8.2.3.1.1INTEGERread-onlyDrive Box Access Path Controller Index. The controller index indicates to which adapter card instance this table entry belongs.
INT cpqSsDrvBoxPathBoxIndex1.3.6.1.4.1.232.8.2.3.1.2INTEGERread-onlyDrive Box Access Path Box Index. The box index indicates to which box instance on an adapter card this table entry belongs. The value of this index is the same as cpqSsDrvBoxBusIndex used under the drive box table.
INT cpqSsDrvBoxPathIndex1.3.6.1.4.1.232.8.2.3.1.3INTEGERread-onlyDrive Box Access Path Index. This path index keeps track of multiple instances of access paths from a controller to a storage box. This number, along with the cpqSsDrvBoxPathCntlrIndex and cpqSsDrvBoxPathDrvIndex uniquely identify a specific storage box access path
INT cpqSsDrvBoxPathStatus1.3.6.1.4.1.232.8.2.3.1.4INTEGERread-onlyDrive Box Access Path Status. This shows the status of the drive box access path. The following values are valid: Other (1) Indicates that the instrument agent can not determine the status of this access path. OK (2) Indicates the access path is functioning properly. Link Down (3) Indicates that the controller can no longer access the drive box through this path.
INT cpqSsDrvBoxPathCurrentRole1.3.6.1.4.1.232.8.2.3.1.5INTEGERread-onlyDrive Box Access Path Current Role. This shows the current role of drive box acess path. The following values are valid: Other (1) Indicates that the instrument agent does not recognize the role of this access path. Active (2) Indicates that this path is currently the default active I/O path to access the drive box from the controller. Alternate (3) Indicates that this path is currently the alternate I/O path to access the physical drive from the controller.
STR cpqSsDrvBoxPathHostConnector1.3.6.1.4.1.232.8.2.3.1.6DisplayStringread-onlyDrive Box Access Path Host Connector. This is the host connector to which the access path is ultimately attached. If the host connector cannot be determined, the agent will return a NULL string.
INT cpqSsDrvBoxPathBoxOnConnector1.3.6.1.4.1.232.8.2.3.1.7INTEGERread-onlyDrive Box Access Path Box on Connector. The box on connector indicates to which box instance this access path belongs.
STR cpqSsDrvBoxPathLocationString1.3.6.1.4.1.232.8.2.3.1.8DisplayStringread-onlyDrive Box Access Path Location String. This string describes drive box access path in relation to the controller to which it is attached. If the location string cannot be determined, the agent will return a NULL string.
cpqSsTrap1.3.6.1.4.1.232.8.3
CTR cpqSsTrapPkts1.3.6.1.4.1.232.8.3.1Counterread-onlyThe total number of trap packets issued by the enterprise since the instrument agent was loaded.
INT cpqSsTrapLogMaxSize1.3.6.1.4.1.232.8.3.2INTEGERread-onlyThe maximum number of entries that will currently be kept in the trap log. If the maximum size has been reached and a new trap occurs the oldest trap will be removed.
cpqSsTrapLogTable1.3.6.1.4.1.232.8.3.3not-accessibleAn ordered list of trap log entries (conceptually a queue). The trap log entries will be kept in the order in which they were generated with the most recent trap at index 1 and the oldest trap entry at index trapLogMaxSize. If the maximum number size has been reached and a new trap occurs the oldest trap will be removed when the new trap is added so the trapMaxLogSize is not exceeded.
cpqSsTrapLogEntry1.3.6.1.4.1.232.8.3.3.1not-accessibleA description of a trap event.
INT cpqSsTrapLogIndex1.3.6.1.4.1.232.8.3.3.1.1INTEGERread-onlyThe value of this object uniquely identifies this trapLogEntry at this time. The most recent trap will have an index of 1 and the oldest trap will have an index of trapLogMaxSize. Because of the queue-like nature of the trapLog this particular trap event's index will change as new traps are issued.
INT cpqSsTrapType1.3.6.1.4.1.232.8.3.3.1.2INTEGERread-onlyThe type of the trap event that this entry describes. This number refers to an entry in a list of traps enumerating the possible traps the agent may issue.
OCT cpqSsTrapTime1.3.6.1.4.1.232.8.3.3.1.3OCTET STRINGread-onlyThe time of the trap event that this entry describes. The time is given in year (first octet), month, day of month, hour, minute, second (last octet) order. Each octet gives the value in BCD.
cpqSsRaidSystem1.3.6.1.4.1.232.8.4
cpqSsRaidSystemTable1.3.6.1.4.1.232.8.4.1not-accessibleRAID Storage System Table.
cpqSsRaidSystemEntry1.3.6.1.4.1.232.8.4.1.1not-accessibleRAID Storage System Entry.
INT cpqSsRaidSystemIndex1.3.6.1.4.1.232.8.4.1.1.1INTEGERread-onlyRAID Storage System Index. The RAID Storage System index indicates to which storage system instance this table entry belongs.
STR cpqSsRaidSystemName1.3.6.1.4.1.232.8.4.1.1.2DisplayStringread-onlyRAID Storage System Name. This is a description of the RAID Storage System's name. This can be used for identification purposes.
INT cpqSsRaidSystemStatus1.3.6.1.4.1.232.8.4.1.1.3INTEGERread-onlyRAID Storage System Status. This is the current status of the RAID Storage System. This value will be one of the following: other(1) Indicates that the agent does not recognize the state of the RAID Storage System. You may need to upgrade the agent. agentNotRunning(2) Indicates that the Storage Work agent is not running. You need to restart the Storage Work agent. good(3) Indicates that the system is operating properly. warning(4) At least one component of the system failed. communicationLoss(5) The RAID Storage System has a cable or communication problem. Please check all cable connects to the host server.
INT cpqSsRaidSystemCondition1.3.6.1.4.1.232.8.4.1.1.4INTEGERread-onlyRAID Storage System Condition. This is the overall condition of the storage system. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system is degraded. At least one component of the storage system failed. failed(4) The storage system has failed.
STR cpqSsRaidSystemCntlr1SerialNumber1.3.6.1.4.1.232.8.4.1.1.5DisplayStringread-onlyRAID Storage System Controller 1 Serial Number. This is the controller number 1's serial number which is normally display on the front panel. This can be used for identification purposes.
STR cpqSsRaidSystemCntlr2SerialNumber1.3.6.1.4.1.232.8.4.1.1.6DisplayStringread-onlyRAID Storage System Controller 2 Serial Number. This is the controller number 2's serial number which is normally display on the front panel. This can be used for identification purposes.

RFC description

Compaq (HP) storage system management MIB for SAN and storage array monitoring.

Start monitoring HP/Compaq StorageWorks storage array (RAID/logical volume/disk) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download CPQSTSYS-MIB