All MIBs › ALCATEL-IND1-CHASSIS-MIB
Organization: Alcatel-Lucent, Enterprise Solutions Division
Last Updated: 2011-03-23
Category: Hardware and Environment, Vendor: Alcatel-Lucent
Description: Alcatel OmniSwitch chassis management MIB covering hardware modules, fan trays, power supplies, and physical inventory.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is ALCATEL-IND1-CHASSIS-MIB?
ALCATEL-IND1-CHASSIS-MIB is Alcatel's proprietary OmniSwitch (Birds Of Prey product line) chassis-supervision MIB, covering physical chassis and control-module (CMM) objects not addressed by the IETF Entity MIB. It exposes control-module inventory and redundancy state, including software-version tracking (current/next running version), activation timers, and synchronization/certification status between primary and secondary CMMs. This is very much a hardware/software status MIB — it is used to confirm both CMMs (management modules) are synchronized and certified, to check which firmware version is currently running versus staged for next activation, and to verify a version upgrade or CMM failover completed cleanly. The module explicitly notes it supplements — rather than duplicates — the IETF Entity MIB (RFC 2737) for physical chassis objects. It's deployed on Alcatel/Alcatel-Lucent OmniSwitch chassis-based switches where dual CMMs provide management-plane redundancy. Engineers can download the ALCATEL-IND1-CHASSIS-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ALCATEL-IND1-CHASSIS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Alcatel/Alcatel-Lucent OmniSwitch chassis switch
Monitoring Examples
An operator would poll chasControlSynchronizationStatus and chasControlCertifyStatus in chasControlModuleTable, indexed per control module, to confirm the standby CMM is synchronized and certified before a planned failover. chasControlCurrentRunningVersion versus chasControlNextRunningVersion reveals whether a firmware upgrade has been staged but not yet activated, and chasControlDelayedActivateTimer/chasControlActivateTimeout show how long until a pending activation occurs or times out. A CMM reporting an uncertified or unsynchronized status typically means a failover to that module would lose current configuration state.
What Can Be Monitored
- CMM synchronization status
- CMM certification status
- current vs. next running firmware version
- activation timer/timeout
- control module redundancy state
This MIB depends on
Related MIBs
Imported Objects
From ALCATEL-IND1-BASE
| hardentIND1Chassis | OBJECT-IDENTITY |
| hardentIND1Physical | OBJECT-IDENTITY |
From ENTITY-MIB
| PhysicalIndex | |
| entPhysicalIndex | OBJECT-TYPE |
From SNMP-FRAMEWORK-MIB
| SnmpAdminString |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DisplayString | |
| MacAddress | |
| TEXTUAL-CONVENTION | |
| TruthValue |
How to Use in IPNetwork Monitor
Example using chasControlNumberOfTakeover OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| I32 alaChasBpsChassisId | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2.1.1 | Integer32 | not-accessible | Numbers allocated for the stack NIs as follows: - 1..8: valid and assigned slot numbers corresponding to values from the entPhysicalTable |
| STR alaChasBpsCmcuRev | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1.1.5 | SnmpAdminString | read-only | This object contains the CMCU revision Number of the BPS |
| STR alaChasBpsConnectorNum | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2.1.4 | SnmpAdminString | read-only | This object specifies the bps connector num. |
| I32 alaChasBpsConnectorPriority | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2.1.3 | Integer32 | read-write | This object specifies the bps connector priority. |
| alaChasBpsConnectorPriorityEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2.1 | not-accessible | Information about bps connector priority for each slot | |
| alaChasBpsConnectorPriorityGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.16 | Information about BPS Connector Priority group. | ||
| alaChasBpsConnectorPriorityTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2 | not-accessible | This table contains BPS connector priority for each slot | |
| ALA alaChasBpsConnectorShelfId | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2.1.2 | AlaChasBpsShelfId | read-only | Bps shelf ID |
| STR alaChasBpsCpldRev | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1.1.3 | SnmpAdminString | read-only | This object contains the CPLD revision Number of the BPS |
| alaChasBpsFwEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1.1 | not-accessible | Information about a bps firrmare | |
| alaChasBpsFwGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.15 | Information about BPS FW group. | ||
| alaChasBpsFwTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1 | not-accessible | This table contains one row per shelf bps firrmware | |
| STR alaChasBpsMmcuRev | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1.1.4 | SnmpAdminString | read-only | This object contains the MMCU revision Number of the BPS |
| INT alaChasBpsMode | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.3.1.1 | INTEGER | read-write | This object is only applicable to BPS .Value is used to specify current Mode of switch. |
| alaChasBpsModeEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.3.1 | not-accessible | Information about bps mode | |
| alaChasBpsModeGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.17 | Information about BPS Mode group. | ||
| alaChasBpsModeTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.3 | not-accessible | This table contains one row for bps config parameters. | |
| alaChasBpsObjects | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14 | |||
| I32 alaChasBpsPoeTotalAllocation | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.5.1.4 | Integer32 | read-only | This value is only applicable to the Bps Modules. It corresponds to total POE power allocated by BPS This value is in Watts. |
| I32 alaChasBpsPoeTotalAvailablePower | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.5.1.3 | Integer32 | read-only | This value is only applicable to the BPS Modules. It corresponds to system total power available on BPS This value is in Watts. |
| STR alaChasBpsPowerSupplyDescr | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.4 | SnmpAdminString | read-only | This object hold description of BPS power supply |
| alaChasBpsPowerSupplyEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1 | not-accessible | Information about a particular BPS power supply | |
| alaChasBpsPowerSupplyGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.18 | BPS Power Supply group. | ||
| STR alaChasBpsPowerSupplyHardwareRev | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.7 | SnmpAdminString | read-only | The vendor-specific hardware revision string for the BPS power supplies Note that if revision information is stored internally in a non-printable (e.g., binary) format, then the agent must convert such information to a printable format, in an implementation-specific manner. If no specific hardware revision string is associated with the physical component, or this information is unknown to the agent, then this object will contain a zero-length string. |
| I32 alaChasBpsPowerSupplyIndex | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.2 | Integer32 | not-accessible | This value hold BPS power power supply Index |
| STR alaChasBpsPowerSupplyMfgDate | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.9 | SnmpAdminString | read-only | This object contains the manufacturing date of the BPS power supplies . Its format is mmm dd yyyy : NOV 27 2012. |
| STR alaChasBpsPowerSupplyModuleType | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.5 | SnmpAdminString | read-only | This object is unique module Type or ID from BPS entities eeprom |
| STR alaChasBpsPowerSupplyName | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.3 | SnmpAdminString | read-only | This object hold name of BPS power supply |
| INT alaChasBpsPowerSupplyOperStatus | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.10 | INTEGER | read-only | Oper status of BPS power supply |
| STR alaChasBpsPowerSupplyPartNumber | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.6 | SnmpAdminString | read-only | This object contains the BPS power supply Part Number |
| I32 alaChasBpsPowerSupplyPowerProv | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.11 | Integer32 | read-only | It corresponds to max power of BPS power supply. This value is in Watts. |
| STR alaChasBpsPowerSupplySerialNum | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.8 | SnmpAdminString | read-write | The vendor-specific serial number string for the BPS power supplies |
| ALA alaChasBpsPowerSupplyShelfId | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.1 | AlaChasBpsShelfId | not-accessible | BPS shelf ID |
| alaChasBpsPowerSupplyTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4 | not-accessible | This table contains BPS power supplies details | |
| STR alaChasBpsSerialNum | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2.1.5 | SnmpAdminString | read-only | This object specifies the bps serial num. |
| ALA alaChasBpsShelfId | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1.1.1 | AlaChasBpsShelfId | not-accessible | Bps shelf ID |
| I32 alaChasBpsSysTotalAllocation | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.5.1.2 | Integer32 | read-only | This value is only applicable to the BPS Modules. It corresponds to total system power allocated by BPS This value is in Watts. |
| I32 alaChasBpsSysTotalAvailablePower | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.5.1.1 | Integer32 | read-only | This value is only applicable to the BPS Module. It corresponds to system total power available on BPS This value is in Watts. |
| alaChasBpsTotalPowerAllocEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.5.1 | not-accessible | Information about various bps config parameters | |
| alaChasBpsTotalPowerAllocGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.19 | BPS Total Power Alloc group. | ||
| alaChasBpsTotalPowerAllocTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.5 | not-accessible | This table contains one row for parameters which reflect total allocation by BPS . | |
| INT alaChasBpsUpdateFirmware | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1.1.2 | INTEGER | read-write | This object is used to start BPS firmware update. |
| INT alaChasEntPhysFanAirflow | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.11.1.3 | INTEGER | read-only | Chassis fan airflow direction |
| alaChasEntPhysFanEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.11.1 | not-accessible | Information about a particular fan in a chassis physical entity. | |
| alaChasEntPhysFanGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.7 | Chassis Supervision Physical Fan Group. | ||
| I32 alaChasEntPhysFanLocalIndex | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.11.1.1 | Integer32 | not-accessible | Index to a chassis fan entity |
| INT alaChasEntPhysFanStatus | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.11.1.2 | INTEGER | read-only | Chassis fan operational status |
| alaChasEntPhysFanTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.11 | not-accessible | This table contains one row per physical fan entity. | |
| alaChasNotificationObjectGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.9 | Chassis Supervision Notification Object Group. | ||
| alcatelIND1ChassisMIB | 1.3.6.1.4.1.6486.801.1.1.1.3.1 | This module describes an authoritative enterprise-specific Simple etwork Management Protocol (SNMP) Management Information Base (MIB): For the Birds Of Prey Product Line, this is the Chassis Supervision Chassis MIB for managing physical chassis objects not covered in the IETF Entity MIB (rfc 2737). The right to make changes in specification and other information contained in this document without prior notice is reserved. No liability shall be assumed for any incidental, indirect, special, or consequential damages whatsoever arising from or related to this document or the information contained herein. Vendors, end-users, and other interested parties are granted non-exclusive license to use this specification in connection with management of the products for which it is intended to be used. Copyright (C) 1995-2007 Alcatel-Lucent ALL RIGHTS RESERVED WORLDWIDE | ||
| alcatelIND1ChassisMIBCompliance | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.2.1 | Compliance statement for Chassis Supervision. | ||
| alcatelIND1ChassisMIBCompliances | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.2 | Branch For Chassis Supervision Chassis MIB Subsystem Compliance Statements. | ||
| alcatelIND1ChassisMIBConformance | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2 | Branch For Chassis Supervision Chassis MIB Subsystem Conformance Information. | ||
| alcatelIND1ChassisMIBGroups | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1 | Branch For Chassis Supervision Chassis MIB Subsystem Units Of Conformance. | ||
| alcatelIND1ChassisMIBNotifications | 1.3.6.1.4.1.6486.801.1.1.1.3.1.0 | Branch For Chassis MIB Subsystem Notifications. | ||
| alcatelIND1ChassisMIBObjects | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1 | Branch For Chassis Supervision Chassis MIB Subsystem Managed Objects. | ||
| alcatelIND1ChassisPhysMIBCompliance | 1.3.6.1.4.1.6486.801.1.1.1.1.2.2.1 | Compliance statement for Chassis Supervision Physical. | ||
| alcatelIND1ChassisPhysMIBCompliances | 1.3.6.1.4.1.6486.801.1.1.1.1.2.2 | Branch For Chassis Supervision Chassis Physical MIB Subsystem Compliance Statements. | ||
| alcatelIND1ChassisPhysMIBConformance | 1.3.6.1.4.1.6486.801.1.1.1.1.2 | Branch For Chassis Supervision Chassis Physical MIB Subsystem Conformance Information. | ||
| alcatelIND1ChassisPhysMIBGroups | 1.3.6.1.4.1.6486.801.1.1.1.1.2.1 | Branch For Chassis Supervision Chassis Physical MIB Subsystem Units Of Conformance. | ||
| alcatelIND1ChassisPhysMIBObjects | 1.3.6.1.4.1.6486.801.1.1.1.1.1 | Branch For Chassis Supervision Chassis Physical MIB Subsystem Managed Objects. | ||
| alcatelIND1ChassisSupervisionRfsCommands | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5 | Branch For Chassis Supervision RFS commands. For rrm command the Slot, Command and SrcFileName are mandatory. For rcp command the Slot, Command, SrcFileName and DestFileName are mandatory. For rdf command the Slot and Command are mandatory | ||
| I32 chasCFMAHardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.9 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the CFMA fabric board. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasCFMBHardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.11 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the CFMB fabric board. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasCFMCHardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.12 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the CFMC fabric board. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasCFMDHardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.13 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the CFMD fabric board. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| chasChassisEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1 | not-accessible | Information about a particular control module this table is an extension of the entity physical table but this class is instanciated only for a particular type of physical entity: the control module that has a particular Index. | |
| chasChassisGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.3 | Chassis Supervision Chassis Group. | ||
| chasChassisTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3 | not-accessible | This table contains one row per chassis. There is always at least one chassis or many when running in virtual chassis mode. | |
| INT chasControlAcrossCmmCertifiedSynchroStatus | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.7 | INTEGER | read-only | Returned value indicates if the /certified has been synchronized across the CMMs if present) |
| INT chasControlAcrossCmmWorkingSynchroStatus | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.6 | INTEGER | read-only | Returned value indicates if the /working has been synchronized across the CMMs (that is the working directory matches the working directory on all CMMs if present) |
| I32 chasControlActivateTimeout | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.1 | Integer32 | read-write | This value is in seconds. It represents how much time before the switch automatically falls back to the certified version. This value is set via the Activate(reload working) cli command. An Activate reboot must be initiated via the primary CMM and that the timeout value can be accessed via user interface to the primary CMM only. After the Activate reboot has been initiated, a timeout will occur (i.e., an Activate Timeout) at the timeout value specified by the user. If a reboot cancel has not been received prior to the timeout expiration, the primary CMM will automatically reboot (i.e., re-reboot) using the certified configuration. This ensures that an automatic backup reboot is available using the certified configuration in the event that the user is unable to interface with primary CMM as a result of the attempted Activate reboot. If the Activate reboot is successful, the user cancels the backup reboot via the normal reboot cancellation process (i.e., a zero value is written for the object chasControlDelayedRebootTimer). |
| INT chasControlCertifyStatus | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.4 | INTEGER | read-only | Returned value indicates if the control module has been certified (that is the working directory matches the certified directory) |
| I32 chasControlChassisId | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.14 | Integer32 | read-write | The virtual chassis id for the action specified by chasControlVersionMngt when operating in virtual chassis mode. A value of 0 indicates the local chassis. |
| STR chasControlCurrentRunningVersion | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.9 | SnmpAdminString | read-write | The pathname of the image directory to the version that is currently executing. Value may be /flash/certified or /flash/. |
| U32 chasControlDelayedActivateTimer | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.3 | Unsigned32 | read-write | Timer value in seconds used to initiate a delayed activate of the primary CMM. Writing this object to a non-zero value results in CMM reboot of the working directory following expiration of the specified activate timer delay. Writing this object to zero results in an immediately activate process. It is now adjusted to wait a maximum of 366 days. |
| U32 chasControlDelayedRebootTimer | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.2.1.2 | Unsigned32 | read-write | Timer value (in seconds) used to initiate a delayed reboot of the primary or secondary CMM using the certified configuration. Writing this object to a non-zero value results in a CMM reboot following expiration of the specified reset timer delay. Writing this object to zero results in cancellation of a pending CMM delayed reboot. It is now adjusted to wait a maximum of 366 days. |
| I32 chasControlDelayedResetAll | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.2.1.3 | Integer32 | read-write | This object is used to schedule a delayed reset all action for a chassis when running in virtual chassis mode. If set to -1 - cancel the timer, 0 - reset all immediately, any other value will start counting down the time until reset. |
| IP chasControlEmpIpAddress | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.12 | IpAddress | read-write | This object is deprecated. Instead use alaInterfaceTable(ALCATEL-IND1-IP-MIB) when configuring EMP interfaces. The IP Address for the primary control module EMP interface. This address is used for managing the chassis and will continue as the EMP interface address after a takeover. |
| IP chasControlEmpIpMask | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.13 | IpAddress | read-write | This object is deprecated. Instead use alaInterfaceTable(ALCATEL-IND1-IP-MIB) when configuring EMP interfaces. The IP Address Mask for the primary control module EMP interface. This address mask is used for managing the chassis and will continue as the EMP interface mask after a takeover. |
| chasControlModuleEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1 | not-accessible | Information about the primary control module. This table is an extension of the entity physical table but this class is instanciated only for a the primary control module that has a particular Index. When operatiing in virtual chassis mode only the master primary control module is instanciated | |
| chasControlModuleGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.1 | Chassis Supervision Control Modules Group. | ||
| chasControlModuleTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1 | not-accessible | This table contains one row for the primary control module. | |
| STR chasControlNextRunningVersion | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.8 | SnmpAdminString | read-only | The pathname for the image directory that will be used on the next reload. Value may be /flash/certified or /flash/. |
| C32 chasControlNumberOfTakeoverEx | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.2.1.1 | Counter32 | read-only | This object is a count of the number of times the control module has changed from primary to secondary mode as a result of a Takeover. Note that this object can be accessed via user interface to either the primary or secondary CMM. The value returned is the number of times that the interfacing control module (either primary or secondary CMM) has changed from primary to secondary mode. This value does not reflect the total number of CMM Takeovers for the switch. To get the total number of Takeovers for the switch, it is necessary to read this value via user interface to each control module independently. |
| I32 chasControlRedundancyTime | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.11 | Integer32 | read-write | Time in minutes that the running image must stay up without error before a subsequent error reset will restart the board from the running image. If a CMM in dual-CMM switch fails after a reload and before chasControlRedundancyTime expires, both CMMs will be rebooted from the certified version. |
| chasControlRedundantEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.2.1 | not-accessible | Information about a particular control module this table is an extension of the entity physical table but this class is instanciated only for a particular type of physical entity: the control module that has a particular Index. When running in virtual chassis mode, entries are instantiated for the Master and all the slave CMMs | |
| chasControlRedundantGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.2 | Chassis Supervision Redundant Control Modules Group. | ||
| chasControlRedundantTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.2 | not-accessible | This table contains one row per control module. There is always at least one control module in the system. | |
| chasControlReloadEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.6.1 | not-accessible | Entry of a network interface reload status | |
| I32 chasControlReloadIndex | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.6.1.1 | Integer32 | not-accessible | The index (entPhsycialIndex) value of the network interface. |
| INT chasControlReloadStatus | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.6.1.2 | INTEGER | read-only | Returned value indicates if the network interface module is enabled or disabled for reload. |
| chasControlReloadStatusGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.4 | Chassis Supervision NI Reload Status Control Modules Group. | ||
| chasControlReloadStatusTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.6 | not-accessible | Table containing reload status of each network interface slot or stack module | |
| INT chasControlSynchronizationStatus | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.5 | INTEGER | read-only | Returned value indicates if the control module has been synchronized (that is the working directory matches the working directory on the other control module(s) if present). Returned value is monoControlModule when no other control module is present. |
| INT chasControlVersionMngt | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.2 | INTEGER | read-write | For the primary this means: notSignificant - No command applied. certifySynchro - Copy the file from the working to the certified directory and from the primary to the secondary (reboot of the secondary). certifyNoSynchro - Copy the file from the working to the certified directory. flashSynchro - Copy the file from the primary to the secondary (reboot of the secondary). restore - Copy the file from the certified directory to the working directory. activate - Reload from the working directory. Activate can be scheduled. issu - In Service Software Upgrade (ISSU). shutdown - Shutdown chassis specified by chasControlChassisId. Halts and powers off NIs, halts primary and secondary CMMs. vcConvert - Copy the image files from the running directory to the working directory. |
| STR chasControlWorkingVersion | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.10 | SnmpAdminString | read-write | The path to the currently specified working image directory. Value may be /flash/certified or /flash/. |
| I32 chasCPMAHardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.8 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the CPMA control module board. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasCPMBHardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.10 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the CPMB control module board. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasDangerTempThreshold | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.6 | Integer32 | read-only | This Threshold is a second one which is hardcoded. When the Chassis Exceeds this value it starts shutting down NIs. This value will be set by the factory and not changeable. |
| INT chasEntPhysAdminStatus | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.1 | INTEGER | read-write | All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value: powerOn powered up Control Module possible value: powerOn CM up and running reset CM reset takeover Secondary CM takes over resetAll resets the whole switch vcTakeover Reloads master chassis from the current working directory, which initiates a VC takeover. vcResetAll resets entire VC. NI status possible value: powerOn NI is either powered (up or down) or waiting to be powered whenever more power is available. This admin status has not full meaning without chasEntPhysOperStatus powerOff NI down and unpowered and NI will not be powered until user requests it, a failover happens or a reboot happens reset NI reset FABRIC status possible value: powerOn FABRIC is powered powerOff FABRIC is unpowered standby FABRIC is powered and requested to be redundant (inactive) Daughter board status possible value: powerOn DB up and running reset DB reset (TO BE CONFIRMED) Power supply status possible value: powerOn PS up |
| INT chasEntPhysAirflow | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.33 | INTEGER | read-only | Chassis PS fan airflow direction |
| STR chasEntPhysAsic1Rev | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.17 | SnmpAdminString | read-only | This object contains the ASIC revision Number of the ni entity |
| STR chasEntPhysAsic2Rev | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.18 | SnmpAdminString | read-only | This object contains the ASIC revision Number of the ni entity |
| STR chasEntPhysAsic3Rev | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.19 | SnmpAdminString | read-only | This object contains the ASIC revision Number of the ni entity |
| STR chasEntPhysAsic4Rev | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.20 | SnmpAdminString | read-only | This object contains the ASIC revision Number of the ni entity |
| STR chasEntPhysAsic5Rev | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.21 | SnmpAdminString | read-only | This object contains the ASIC revision Number of the ni entity |
| STR chasEntPhysAsic6Rev | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.22 | SnmpAdminString | read-only | This object contains the ASIC revision Number of the ni entity |
| STR chasEntPhysCpldRev | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.23 | SnmpAdminString | read-only | This object contains the CPLD revision Number of the ni entity |
| STR chasEntPhysCpuModel | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.32 | SnmpAdminString | read-only | This object contains the model description of the cmm/ni cpu |
| STR chasEntPhysDaughterFpga1Rev | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.24 | SnmpAdminString | read-only | This object contains the daughter fpga revision Number of the ni entity |
| STR chasEntPhysDaughterFpga2Rev | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.25 | SnmpAdminString | read-only | This object contains the daughter fpga revision Number of the ni entity |
| I32 chasEntPhysGbicNum | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.27 | Integer32 | read-only | This value is only applicable to the NI. It indicates a gbic associated with this ni |
| chasEntPhysicalEntry | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1 | not-accessible | Information about a particular physical entity. | |
| chasEntPhysicalGroup | 1.3.6.1.4.1.6486.801.1.1.1.1.2.1.1 | Chassis (inclosure) Entity Physical Group. | ||
| chasEntPhysicalTable | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1 | not-accessible | This table contains one row per physical entity. It is an extension for the entity physical table (rfc 2737) that is instantiated for every physical entity object. The fields are not always significant for every object. | |
| CHA chasEntPhysLedStatusBackupPS | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.12 | ChasEntPhysLed | read-only | Chassis backup power supply status indication |
| CHA chasEntPhysLedStatusControl | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.14 | ChasEntPhysLed | read-only | Chassis control status |
| CHA chasEntPhysLedStatusFabric | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.15 | ChasEntPhysLed | read-only | Chassis Management Module (CMM) Fabric status indication |
| CHA chasEntPhysLedStatusFan | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.11 | ChasEntPhysLed | read-only | For Hawk stacks used as a fan group status LED. For eagle CMM's user instead: Fan 1 (top left), Fan 2 (top right), Fan 3 (rear) |
| CHA chasEntPhysLedStatusInternalPS | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.13 | ChasEntPhysLed | read-only | Chassis internal power supply status indication |
| CHA chasEntPhysLedStatusOk1 | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.6 | ChasEntPhysLed | read-only | Chassis Management Module (CMM) front panel LED OK1 status indication |
| CHA chasEntPhysLedStatusOk2 | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.7 | ChasEntPhysLed | read-only | Chassis Management Module (CMM) front panel LED OK2 status indication |
| CHA chasEntPhysLedStatusPrimaryCMM | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.8 | ChasEntPhysLed | read-only | Chassis Management Module (CMM) front panel LED Primary chassis indication |
| CHA chasEntPhysLedStatusPS | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.16 | ChasEntPhysLed | read-only | Chassis Power Supply Unit status indication |
| CHA chasEntPhysLedStatusSecondaryCMM | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.9 | ChasEntPhysLed | read-only | Chassis Management Module (CMM) front panel LED Secondary chassis indication |
| CHA chasEntPhysLedStatusTemperature | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.10 | ChasEntPhysLed | read-only | Chassis Management Module (CMM) front panel LED temperature status indication |
| MAC chasEntPhysMacAddress | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.31 | MacAddress | read-only | This object contains the MAC address of the ni entity |
| STR chasEntPhysModuleType | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.4 | SnmpAdminString | read-only | This object is the unique Module Type or ID from the entities eeprom. This value is guarrantteed to be unique to each type of Module. This value is only intended for Alcatel internal use. |
| I32 chasEntPhysNiNum | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.26 | Integer32 | read-only | This value is only applicable to the NI. It indicates an NI associated with this physicalEntry |
| INT chasEntPhysOperStatus | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.2 | INTEGER | read-only | All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value : up powered up Control Module possible value : notPresent CM not present up CM up and running down CM down and powered secondary CM in secondary mode and running NI status possible value : notPresent NI not present up NI up and running down NI down and powered unpowered NI unpowered because there is not enough power in the system (chasEntPhysAdminStatus = powerOn) or because the NI has to be OFF (chasEntPhysAdminStatus = powerOff). This operational status has not full meaning without chasEntPhysAdminStatus Fabric status possible value : master up and acting as master up up and acting as slave secondary secondary mode for redundancy Daughter board status possible value : notPresent DB not present up DB up and running down DB down and powered Power supply status possible value : up PS up down PS administratively down unpowered PS not plugged in pwrsave chassis in powersave mode, supply turned off Fan Tray status possible value : up powered up down powered down fault fault detected |
| STR chasEntPhysPartNumber | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.5 | SnmpAdminString | read-only | This object contains the Alcatel Part Number for the entity. This value is used to identify what is needed when placing orders with Alcatel. |
| I32 chasEntPhysPower | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.3 | Integer32 | read-only | This value is only applicable to the NI, PS and Control Modules. It corresponds to a a static value for the power consumption of an NI module or Control Module. This value is in Watts. |
| I32 chasEntPhysPowerUsed | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.34 | Integer32 | read-only | This value is only applicable to the PS. It is the current reading for the power usage of the PS. This value is in Watts. |
| STR chasEntPhysUbootMinibootRev | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.30 | SnmpAdminString | read-only | This object contains the uboot miniboot version Number of the ni entity |
| STR chasEntPhysUbootRev | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.29 | SnmpAdminString | read-only | This object contains the uboot version Number of the ni entity |
| I32 chasEntPhysWaveLen | 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.28 | Integer32 | read-only | This object contains the wave length of a SFP device |
| I32 chasEntTempCurrent | 1.3.6.1.4.1.6486.801.1.1.1.1.1.2.1.1 | Integer32 | read-only | This object indicates the current output of the temperature sensor in degrees Celsius. |
| I32 chasEntTempDangerThreshold | 1.3.6.1.4.1.6486.801.1.1.1.1.1.2.1.3 | Integer32 | read-only | This object is the danger threshold temperature in degrees Celsius for the sensor. When the value of chasEntTempCurrent exceeds this value, the associated physical entity is powered down. |
| chasEntTemperatureEntry | 1.3.6.1.4.1.6486.801.1.1.1.1.1.2.1 | not-accessible | Information about a particular physical temperature sensor. | |
| chasEntTemperatureTable | 1.3.6.1.4.1.6486.801.1.1.1.1.1.2 | not-accessible | This table contains one row per temperature sensor located on an entity represented by the associated row in the entPhysicalTable. | |
| INT chasEntTempStatus | 1.3.6.1.4.1.6486.801.1.1.1.1.1.2.1.4 | INTEGER | read-only | This object is the status value of the temperature sensor. It reflects the temperature relative to the chasEntTempThreshold and chasEntTempDangerThreshold values. |
| I32 chasEntTempThreshold | 1.3.6.1.4.1.6486.801.1.1.1.1.1.2.1.2 | Integer32 | read-only | This object is the threshold temperature in degrees Celsius for the sensor. When the value of chasEntTempCurrent exceeds this value, a temperature notification is provided to the user. |
| U32 chasFreeSlots | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.1 | Unsigned32 | read-only | The number of free NI front panel slots. |
| I32 chasFTAHardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.14 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for Fantray 1. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasFTBHardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.15 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for Fantry 2. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| chasGlobalControl | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7 | |||
| STR chasGlobalControlConfirmMessage | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.9 | DisplayString | read-only | When operating in virtual chassis mode, this object may be read when chasGlobalControlLongCommandStatus is set to confirmationRequired(5). This will happen when an operation such a reload may disrupt the virtual chassis. This object contains information about the consequences of executing the command identified by chasGlobalControlLongCommand. The command has been suspended. To accept the consequences and proceed with the operation, set chasGlobalControlConfirmOperation to true. |
| T/F chasGlobalControlConfirmOperation | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.8 | TruthValue | read-write | When operating in virtual chassis mode, this object can be set to true(1) to confirm that the operation identified by chasGlobalControlLongCommand can proceed. Set to false(2) to cancel the operation. This should only be used when chasGlobalControlLongCommandStatus is set to confirmationRequired(5), and the value of chasGlobalControlConfirmMessage has been reviewed. |
| I32 chasGlobalControlDelayedResetAll | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.1 | Integer32 | read-write | This object is used to schedule a delayed reset all action for a standalone chassis or for the entire virtual chassis when running is virtual chassis mode. To schedule a delayed reset on a specific chassis when running is virtual chassis mode, use the chasControlDelayedResetAll object for the desired chassis. If set to -1 - cancel the timer, 0 - reset all immediately, any other value will start counting down the time until reset. |
| chasGlobalControlGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.5 | Chassis Supervision Global Control Modules Group. | ||
| INT chasGlobalControlLongCommand | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.2 | INTEGER | read-only | This object is used to indicate whether a long-term action is in progress, and if so, what the action is. |
| INT chasGlobalControlLongCommandStatus | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.3 | INTEGER | read-only | This object indicates the final disposition of the most recent long-term action. When running in virtual chassis mode, the value confirmationRequired(5), indicates that the command identified in chasGlobalControlLongCommand may disrupt the virtual chassis. The command is suspended and requires that chasClobalControlConfirmOperation be set to true, after reviewing the details and accepting the consequences identified by chasGlobalControlConfirmMessage. |
| STR chasGlobalControlUpdateFilename | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.6 | SnmpAdminString | read-write | This object identifies the filename containing the uboot firmware image. |
| INT chasGlobalControlUpdateFirmware | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.4 | INTEGER | read-write | This object initiates a firmware update. The chasGlobalControlUpdateSlot and chasGlobalControlUpdateFilename objects must be set prior to setting this object to start the update. The progress of the update can be monitored by reading chasGlobalControlUpdateStatus. |
| I32 chasGlobalControlUpdateSlot | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.5 | Integer32 | read-write | This object identifies the slot to be updated. The Slot value is the entPhysicalIndex of the NI or CMM entry in the entPhyscialTable. A value of 0 may be specified to update all NIs or CMMs. The value of 0 is supported only for uboot updates. |
| INT chasGlobalControlUpdateStatus | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.7 | INTEGER | read-only | This object reports the status of the firmware update. The status for the the update identified by chasGlobalControlUpdateFirmware and chasGlobalControlUpdateSlot is returned. When ubootNiAll(4) ubootCmmAll(5) or fpgaCmmAll(10) update is executed, the status of individual NIs or CMMs may be monitored by changing the value of chasGlobalControlUpdateSlot to the desired NI or CMM slot value prior to reading the status. noUpdate(1) - No firmware update has been initiated. updateInProgress(2) - Update is in progress. updateSuccess(3) - The last firmware update was successful. updateFailed(4) - The last firmware update failed. |
| I32 chasNI1HardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.16 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 1. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasNI2HardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.17 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 2. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasNI3HardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.18 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 3. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasNI4HardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.19 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 4. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasNI5HardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.20 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 5. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasNI6HardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.21 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 6. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasNI7HardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.22 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 7. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| I32 chasNI8HardwareBoardTemp | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.23 | Integer32 | read-only | This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 8. This temperature is what is used for comparing to the threshold and determining whether the value is in range. |
| C32 chasNumberOfResets | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.3 | Counter32 | read-only | This object is a count of the number of times this station has been reset since a cold-start. |
| I32 chasPowerLeft | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.2 | Integer32 | read-only | The power still available on the chassis in Watts. |
| INT chasPowerSupplyRedundancy | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.24 | INTEGER | read-write | This object indicates the state of power supply redundancy mode. When on(1), N+1 mode redundancy is enabled(default mode). In this mode the system controls the power supplies to maintain efficient use of the power supplies, with 1 extra power supply in case of a power supply failure. Unneeded power supplies are powered off. It can be set to off(2) to disable redundancy mode. In this mode all power supplies are powered on. |
| I32 chasPrimaryPhysicalIndex | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.7 | Integer32 | read-only | This value holds the Entity Table Physical Index for the Control Module that is currently primary. This is to allow snmp managers to determine which Control Module is currently primary so it knows what entry in the chasControlModuleTable to access for setting the chasControlVersionMngt values for controling the switch. When running in virtual chassis mode, it will contain the Physical Index of the master primary Control Module. |
| chassisNotificationGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.6 | Chassis Supervision Notification Group. | ||
| chassisPhysNotificationGroup | 1.3.6.1.4.1.6486.801.1.1.1.1.2.1.2 | Chassis Supervision Physical Notification Group. | ||
| chassisSupervisionRfsCommandsGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.10 | Chassis Supervision RFS Command Group. | ||
| chassisTemperatureGroup | 1.3.6.1.4.1.6486.801.1.1.1.1.2.1.3 | Chassis Supervision Temprature Group. | ||
| NTF chassisTrapsAlert | 1.3.6.1.4.1.6486.801.1.1.1.3.1.0.2 | generic trap notifying something changed in the chassis whatever it's a failure or not | ||
| STR chassisTrapsAlertDescr | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.12 | SnmpAdminString | read-only | description of the alert matching chassisTrapsAlertNumber |
| CHA chassisTrapsAlertNumber | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.11 | ChassisTrapsAlertNumber | read-only | this number identify the alert among all the possible chassis alert causes. |
| chassisTrapsObj | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13 | |||
| CHA chassisTrapsObjectNumber | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.10 | ChassisTrapsObjectNumber | read-only | number defining the order of the object in the set. EX: number of the considered fan or power supply. This intend to clarify as much as possible the location of the failure or alert. A instance of the appearance of the trap could be: failure on a module. Power supply 3. |
| CHA chassisTrapsObjectType | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.9 | ChassisTrapsObjectType | read-only | enumerated value which provide the object type involved in the alert trap. |
| NTF chassisTrapsStateChange | 1.3.6.1.4.1.6486.801.1.1.1.3.1.0.3 | A status change was detected | ||
| NTF chassisTrapsStr | 1.3.6.1.4.1.6486.801.1.1.1.3.1.0.1 | A Software Trouble report is sent by whatever application encountering a problem during its execution and would want to aware the user of for maintenance purpose. | ||
| CHA chassisTrapsStrAppID | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.2 | ChassisTrapsStrAppID | read-only | Application Identification number |
| STR chassisTrapsStrcomments | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.7 | SnmpAdminString | read-only | comment text explaning the fault. |
| CHA chassisTrapsStrdataInfo | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.8 | ChassisTrapsStrdataInfo | read-only | Additional data provided to help to find out the origine of the fault. The contain and the significant portion are varying in accordance with chassisTrapsStrErrorNb. The lenght of this field is expressed in bytes. |
| CHA chassisTrapsStrErrorNb | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.6 | ChassisTrapsStrErrorNb | read-only | Fault identificator. The error number identify the kind the detected fault and allow a mapping of the data contained in chassisTrapsdataInfo. |
| CHA chassisTrapsStrfileLineNb | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.5 | ChassisTrapsStrfileLineNb | read-only | Line number in the source file where the fault was detected. This is given by the C ANSI macro __LINE__. |
| STR chassisTrapsStrfileName | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.4 | SnmpAdminString | read-only | Name of the source file where the fault was detected. This is given by the C ANSI macro __FILE__. The path shouldn't appear. |
| CHA chassisTrapsStrLevel | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.1 | ChassisTrapsStrLevel | read-only | An enumerated value which provides the urgency level of the STR. |
| CHA chassisTrapsStrSnapID | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.3 | ChassisTrapsStrSnapID | read-only | Subapplication Identification number. we can have multiple snapIDs per Subapplication (task) but only one is to be used to send STRs. |
| chasSupervisionCmmCertifiedEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.10.1 | not-accessible | Information about control module certification status. This class is instanciated only when running in virtual chassis mode. | |
| chasSupervisionCmmCertifiedEntryGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.11 | Information about Cmm Certified Group. | ||
| INT chasSupervisionCmmCertifiedStatus | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.10.1.2 | INTEGER | read-only | The status of the CMM certified directory - certified or not. |
| chasSupervisionCmmCertifiedTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.10 | not-accessible | This table contains certification status | |
| I32 chasSupervisionCmmNum | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.10.1.1 | Integer32 | not-accessible | CMM Slot where /certified directory is evaluated. |
| U32 chasSupervisionFlashFree | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.9.1.3 | Unsigned32 | read-only | Number bytes free on file system. |
| chasSupervisionFlashMemEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.9.1 | not-accessible | This contains one entry for the flash memory table. | |
| chasSupervisionFlashMemEntryGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.12 | The systems flash memory information group. | ||
| chasSupervisionFlashMemTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.9 | not-accessible | This table contains the systems flash memory information. | |
| U32 chasSupervisionFlashSize | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.9.1.2 | Unsigned32 | read-only | Flash memory size. |
| I32 chasSupervisionFlashUsed | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.9.1.4 | Integer32 | read-only | A rounded up percentage of Flash Memory used. |
| INT chasSupervisionRfsCommandsCommand | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.2 | INTEGER | read-write | This object identifies which of the above Actions is to be performed. The commands are as follows: - rrm Remote file remove - rcp Remote file copy (DEPRECATED please use rget or rput instead) - rls Remote directory listing - rdf Remote flash disk space free - rget Remote file get - rput Remote file put |
| STR chasSupervisionRfsCommandsDestFileName | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.4 | SnmpAdminString | read-write | The destination file for where the RFS action is executed. This includes also the path so directory name and file name. This object is used when command set to rget or rput. |
| INT chasSupervisionRfsCommandsProcessingState | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.7 | INTEGER | read-only | command executing state for the previous set operation. |
| STR chasSupervisionRfsCommandsRlsDirName | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.5 | SnmpAdminString | read-write | The remote directory name where remote file is located in. This is used when command set to rls. |
| STR chasSupervisionRfsCommandsRlsFileName | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.6 | SnmpAdminString | read-write | The remote file name where remote file is located in. This is used when command set to rls. |
| U32 chasSupervisionRfsCommandsSlot | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.1 | Unsigned32 | read-write | CMM Slot where RFS command should be executed. |
| STR chasSupervisionRfsCommandsSrcFileName | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.3 | SnmpAdminString | read-write | The remote file for where the RFS action is executed. This includes also the path so directory name and file name. This object is used when command set to rrm or rget or rput. |
| INT chasSupervisionRfsCommandsStatusCode | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.8 | INTEGER | read-only | command completetion status error code. |
| chasSupervisionRfsDfEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8.1 | not-accessible | This entry contains information about file system size and use. | |
| chasSupervisionRfsDfEntryGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.13 | Information about RfsDf file system group. | ||
| U32 chasSupervisionRfsDfFlashFree | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8.1.2 | Unsigned32 | read-only | Number bytes free on the file system. |
| U32 chasSupervisionRfsDfFlashSize | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8.1.3 | Unsigned32 | read-only | Number of total bytes on the file system. |
| I32 chasSupervisionRfsDfSlot | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8.1.1 | Integer32 | not-accessible | CMM Slot where flash space is evaluated. |
| chasSupervisionRfsDfTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8 | not-accessible | This table contains information about file system size and use. | |
| U32 chasSupervisionRfsDfUsbFree | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8.1.4 | Unsigned32 | read-only | The amount of free space on the USB file system. |
| U32 chasSupervisionRfsDfUsbSize | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8.1.5 | Unsigned32 | read-only | The total amount of space on the USB file system. |
| STR chasSupervisionRfsLsDirName | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.3 | SnmpAdminString | read-only | The remote directory name where remote file is located in |
| chasSupervisionRfsLsEntry | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1 | not-accessible | Information about a remote file. A row in this table contains a file per directory per chassis | |
| chasSupervisionRfsLsEntryGroup | 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.14 | Information about a RfsLs file group. | ||
| INT chasSupervisionRfsLsFileAttr | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.7 | INTEGER | read-only | attributes of this remote file |
| STR chasSupervisionRfsLsFileDateTime | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.8 | SnmpAdminString | read-only | the modification date and time of a remote file |
| I32 chasSupervisionRfsLsFileIndex | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.1 | Integer32 | read-only | This value holds file Index for the RFS LS table. |
| STR chasSupervisionRfsLsFileName | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.4 | SnmpAdminString | read-only | The file name of remote file |
| U32 chasSupervisionRfsLsFileSize | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.6 | Unsigned32 | read-only | size of this remote file |
| INT chasSupervisionRfsLsFileType | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.5 | INTEGER | read-only | The Type of a remote file |
| U32 chasSupervisionRfsLsSlot | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.2 | Unsigned32 | read-only | CMM Slot where remote file is located. |
| chasSupervisionRfsLsTable | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4 | not-accessible | This table contains a list of file on the remote chassis per directory. | |
| I32 chasSupervisionSlot | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.9.1.1 | Integer32 | not-accessible | CMM Slot where flash space is evaluated. |
| INT chasTempRange | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.4 | INTEGER | read-only | Temp Range is the value of the temperature sensor for the chassis. The Temp Range value reflects the temperature of the chassis relative to the Temp Threshold value (i.e., over vs. under the threshold). |
| I32 chasTempThreshold | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.5 | Integer32 | read-write | This object is the threshold temperature in degrees Celsius for the chassis. Temp Threshold is the chassis temperature point at which, when reached due to an ascending or descending temperature transition, a temperature notification is provided to the user. When this threshold is exceeded, we start sending traps and other operator notification. |
| I32 chasTrapBPSShelfId | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.16 | Integer32 | read-only | Granted system power from os-bps |
| CHA chasTrapsBPSEventAlert | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.18 | ChasTrapsBPSEventAlert | read-only | enumerated value identifying alert |
| NTF chasTrapsBPSLessAllocSysPwr | 1.3.6.1.4.1.6486.801.1.1.1.3.1.0.4 | Insufficient system power given by BPS | ||
| CHA chasTrapsBPSPoeFETChange | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.20 | ChasTrapsBPSFetState | read-only | enumerated value which indicate Fet state |
| CHA chasTrapsBPSPowerSupply | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.17 | ChasTrapsBPSPowerSupply | read-only | value which provide bps power supply involved in the State change trap |
| NTF chasTrapsBPSStateChange | 1.3.6.1.4.1.6486.801.1.1.1.3.1.0.5 | BPS power supplies insertion/removal trap | ||
| CHA chasTrapsBPSSystemFETChange | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.19 | ChasTrapsBPSFetState | read-only | enumerated value which indicate Fet state |
| NTF chasTrapsNiBPSFETStateChange | 1.3.6.1.4.1.6486.801.1.1.1.3.1.0.6 | BPS power supplies FET state change trap | ||
| I32 chasTrapsNiGrantdBpsSysPower | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.15 | Integer32 | read-only | Granted system power from os-bps |
| I32 chasTrapsNiRqstdBpsSysPower | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.14 | Integer32 | read-only | Requested system power from os-bps |
| PHY physicalIndex | 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.13 | PhysicalIndex | read-only | The Physical index of the involved object. |
RFC description
Alcatel-Lucent IND1 chassis supervision MIB for monitoring physical chassis objects and resources.