All MIBs › CISCO-FIREPOWER-FABRIC-MIB
Organization: Cisco Systems Inc.
Last Updated: 2022-08-25
Category: Cisco Devices, Hardware and Environment
Description: Provides management objects for fabric interconnect switching infrastructure, port channels, and uplinks on Cisco UCS/Firepower platforms.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CISCO-FIREPOWER-FABRIC-MIB?
CISCO-FIREPOWER-FABRIC-MIB models the switching fabric infrastructure of Cisco UCS/Firepower fabric interconnects, including broadcast/headend VLANs, port channels, and uplink port roles. It exposes tables describing VLAN associations, their primary/secondary switch assignment, and the role and type of each fabric interface. The MIB supports monitoring the operational status of the internal switching fabric, revealing whether VLANs and uplinks are correctly associated with their primary switch and whether interfaces are serving their intended role, which helps diagnose fabric connectivity or failover problems. It is part of the Cisco UCS/Firepower management information model, using the same DN/RN addressing as related Firepower MIBs. It is deployed on Cisco UCS/Firepower fabric interconnects managing blade or rack server chassis. Engineers can download the CISCO-FIREPOWER-FABRIC-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in CISCO-FIREPOWER-FABRIC-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Cisco UCS/Firepower fabric interconnects
Monitoring Examples
An administrator would poll cfprFabricBHVlanTable, reading cfprFabricBHVlanAssocPrimaryVlanState and cfprFabricBHVlanAssocPrimaryVlanSwitchId for each VLAN keyed by cfprFabricBHVlanId, along with cfprFabricBHVlanIfRole and cfprFabricBHVlanIfType to confirm uplink interfaces are correctly assigned. An unexpected primary VLAN state or a switch ID pointing to the wrong fabric interconnect would indicate a broadcast/headend VLAN failover or misconfiguration issue.
What Can Be Monitored
- broadcast/headend VLAN association state
- primary VLAN switch assignment
- interface role and type
- VLAN locale
This MIB depends on
Related MIBs
Imported Objects
From CISCO-FIREPOWER-MIB
| CfprManagedObjectDn | |
| CfprManagedObjectId | |
| ciscoFirepowerMIBObjects | OBJECT-IDENTITY |
| CfprComputeDecommissionState | |
| CfprComputeDiscovery | |
| CfprConditionRemoteInvRslt | |
| CfprEquipmentBoardAggregationRole | |
| CfprEquipmentConnectionStatus | |
| CfprEquipmentEthPortSpeedCap | |
| CfprEquipmentFabricEpType | |
| CfprEquipmentSlotStatus | |
| CfprFabricADceSwSrvEpTransport | |
| CfprFabricAEthEstcEpIfRole | |
| CfprFabricAEthEstcEpTransport | |
| CfprFabricAEthEstcEpType | |
| CfprFabricAEthLanEpTransport | |
| CfprFabricAFcSanEpTransport | |
| CfprFabricAFcoeSanEpTransport | |
| CfprFabricAVlanAssocPrimaryVlanSwitchId | |
| CfprFabricAVlanSharing | |
| CfprFabricAVlanTransport | |
| CfprFabricAVlanType | |
| CfprFabricAVsanTransport | |
| CfprFabricAVsanType | |
| CfprFabricAccessType | |
| CfprFabricAdminState | |
| CfprFabricAllowedVlanType | |
| CfprFabricBHVlanSwitchId | |
| CfprFabricBladeLifeCycle | |
| CfprFabricBreakoutPortId | |
| CfprFabricBreakoutSlotId | |
| CfprFabricBreakoutType | |
| CfprFabricCIoEpAdminState | |
| CfprFabricCIoEpIfType | |
| CfprFabricCdpLinkPolicyAdminState | |
| CfprFabricCloudType | |
| CfprFabricComputeEpIfRole | |
| CfprFabricComputeEpType | |
| CfprFabricComputePhEpAdminState | |
| CfprFabricComputeSlotEpFsmCurrentFsm | |
| CfprFabricComputeSlotEpFsmStageName | |
| CfprFabricComputeSlotEpFsmTaskItem | |
| CfprFabricComputeSlotEpSlotId | |
| CfprFabricConfMode | |
| CfprFabricConfState | |
| CfprFabricConfigState | |
| CfprFabricDceSwSrvEpPortId | |
| CfprFabricDceSwSrvEpSlotId | |
| CfprFabricDceSwSrvPcAdminState | |
| CfprFabricDceSwSrvPcEpPortId | |
| CfprFabricDceSwSrvPcEpSlotId | |
| CfprFabricDceSwSrvPcPortId | |
| CfprFabricDceSwSrvPcTransport | |
| CfprFabricDefaultZoningState | |
| CfprFabricEpMgrFsmCurrentFsm | |
| CfprFabricEpMgrFsmStageName | |
| CfprFabricEpMgrFsmTaskFlags | |
| CfprFabricEpMgrFsmTaskItem | |
| CfprFabricEstcPcIfRole | |
| CfprFabricEstcPcType | |
| CfprFabricEthCdpPolicyProtocol | |
| CfprFabricEthEstcEpPortId | |
| CfprFabricEthEstcEpPrio | |
| CfprFabricEthEstcEpSlotId | |
| CfprFabricEthEstcEpTransport | |
| CfprFabricEthEstcEpType | |
| CfprFabricEthEstcOperPortMode | |
| CfprFabricEthEstcPcEpPortId | |
| CfprFabricEthEstcPcEpSlotId | |
| CfprFabricEthEstcPcTransport | |
| CfprFabricEthEstcPortMode | |
| CfprFabricEthEstcTransport | |
| CfprFabricEthEstcType | |
| CfprFabricEthLanEpAdminState | |
| CfprFabricEthLanEpInlineState | |
| CfprFabricEthLanEpServiceState | |
| CfprFabricEthLanEpVlanStatus | |
| CfprFabricEthLanPcAdminState | |
| CfprFabricEthLanPcInlineState | |
| CfprFabricEthLanPcLacpDetach | |
| CfprFabricEthLanPcServiceState | |
| CfprFabricEthLanPcTransport | |
| CfprFabricEthLanPcVlanStatus | |
| CfprFabricEthLanTransport | |
| CfprFabricEthLinkPolicyType | |
| CfprFabricEthMonDestEpAdminSpeed | |
| CfprFabricEthMonDestEpIfRole | |
| CfprFabricEthMonDestEpPortId | |
| CfprFabricEthMonDestEpSlotId | |
| CfprFabricEthMonDestEpType | |
| CfprFabricEthMonFiltEpType | |
| CfprFabricEthMonFiltRefType | |
| CfprFabricEthMonLanTransport | |
| CfprFabricEthMonLanType | |
| CfprFabricEthMonSrcEpType | |
| CfprFabricEthMonSrcRefType | |
| CfprFabricEthMonTransport | |
| CfprFabricEthMonType | |
| CfprFabricEthPcProtocol | |
| CfprFabricEthSourceType | |
| CfprFabricEthTargetEpTransport | |
| CfprFabricEthUdldPolicyProtocol | |
| CfprFabricEthVlanPcTransport | |
| CfprFabricExternalEpAdminState | |
| CfprFabricExternalEpLocale | |
| CfprFabricExternalLocale | |
| CfprFabricExternalPcLocale | |
| CfprFabricFcSanEpPortId | |
| CfprFabricFcSanEpSlotId | |
| CfprFabricFcSanPcEpPortId | |
| CfprFabricFcSanPcEpSlotId | |
| CfprFabricFcSanPcTransport | |
| CfprFabricFcSanTransport | |
| CfprFabricFcSanUplinkTrunking | |
| CfprFabricFcVsanPcTransport | |
| CfprFabricFcVsanPortEpPortId | |
| CfprFabricFcVsanPortEpSlotId | |
| CfprFabricFcZoneSharingMode | |
| CfprFabricFcoeSanEpPortId | |
| CfprFabricFcoeSanEpSlotId | |
| CfprFabricFcoeSanPcEpPortId | |
| CfprFabricFcoeSanPcEpSlotId | |
| CfprFabricFcoeSanPcTransport | |
| CfprFabricFcoeVsanPcTransport | |
| CfprFabricFcoeVsanPortEpPortId | |
| CfprFabricFcoeVsanPortEpSlotId | |
| CfprFabricFillPattern | |
| CfprFabricInternalDceSrvTransport | |
| CfprFabricInternalDceSrvType | |
| CfprFabricInternalEpAdminState | |
| CfprFabricInternalEpLocale | |
| CfprFabricInternalLocale | |
| CfprFabricInternalPcLocale | |
| CfprFabricLacpMode | |
| CfprFabricLacpRate | |
| CfprFabricLacpSuspend | |
| CfprFabricLanCloudFsmCurrentFsm | |
| CfprFabricLanCloudFsmStageName | |
| CfprFabricLanCloudFsmTaskItem | |
| CfprFabricLanCloudVlanCompression | |
| CfprFabricLanEpIfRole | |
| CfprFabricLanEpType | |
| CfprFabricLanPcIfRole | |
| CfprFabricLanPcType | |
| CfprFabricLanType | |
| CfprFabricLifeCycle | |
| CfprFabricMemberStatus | |
| CfprFabricMembershipStatus | |
| CfprFabricMonAdminState | |
| CfprFabricMonOperState | |
| CfprFabricMonOperStateReason | |
| CfprFabricNetGroupSwitchId | |
| CfprFabricNetGroupType | |
| CfprFabricOwner | |
| CfprFabricPIoEpIfType | |
| CfprFabricPIoEpOperState | |
| CfprFabricPIoEpPortId | |
| CfprFabricPIoEpSlotId | |
| CfprFabricPathEpIfType | |
| CfprFabricPathEpLocale | |
| CfprFabricPcConfigStatus | |
| CfprFabricPcMode | |
| CfprFabricPcModeState | |
| CfprFabricPktCaptureAppSlotId | |
| CfprFabricPoolMemberConfigIssues | |
| CfprFabricQosPrio | |
| CfprFabricQuerierType | |
| CfprFabricRecoveryAction | |
| CfprFabricReqIssues | |
| CfprFabricSSAPortType | |
| CfprFabricSSASubPortType | |
| CfprFabricSanCloudFsmCurrentFsm | |
| CfprFabricSanCloudFsmStageName | |
| CfprFabricSanCloudFsmTaskItem | |
| CfprFabricSanEpIfRole | |
| CfprFabricSanEpType | |
| CfprFabricSanPcIfRole | |
| CfprFabricSanPcType | |
| CfprFabricSanType | |
| CfprFabricSlotAdminState | |
| CfprFabricSnoopingType | |
| CfprFabricSpannedCluster | |
| CfprFabricSspEthMonAppendFlag | |
| CfprFabricSspEthMonDelAllSessEnabledState | |
| CfprFabricSspLanMonCloudDelAllSess | |
| CfprFabricSspMonAdminState | |
| CfprFabricSspMonDelPcap | |
| CfprFabricSspMonOperState | |
| CfprFabricSspMonOperStateReason | |
| CfprFabricStatus | |
| CfprFabricSubGroupAggrPortId | |
| CfprFabricSubGroupConfigState | |
| CfprFabricSubGroupSlotId | |
| CfprFabricSvcStateDownReason | |
| CfprFabricSwChEpIfRole | |
| CfprFabricSwChEpType | |
| CfprFabricSwChPhEpAdminState | |
| CfprFabricSwSrvEpIfRole | |
| CfprFabricSwSrvEpType | |
| CfprFabricSwSrvPcIfRole | |
| CfprFabricSwSrvPcType | |
| CfprFabricSwSubGroupAggrPortId | |
| CfprFabricSwSubGroupConfigState | |
| CfprFabricSwSubGroupSlotId | |
| CfprFabricSwitchingMode | |
| CfprFabricTargetEpType | |
| CfprFabricTargetStatus | |
| CfprFabricTrafficDirection | |
| CfprFabricUdldLinkPolicyAdminState | |
| CfprFabricUdldLinkPolicyMode | |
| CfprFabricUdldOperState | |
| CfprFabricVConInstType | |
| CfprFabricVConMappingScheme | |
| CfprFabricVConPlacementPref | |
| CfprFabricVConSelectPref | |
| CfprFabricVConSharePref | |
| CfprFabricVConTransportPref | |
| CfprFabricVlanAssocPrimaryVlanState | |
| CfprFabricVlanCompType | |
| CfprFabricVlanConfigIssues | |
| CfprFabricVlanOperState | |
| CfprFabricVlanOverlapState | |
| CfprFabricVlanSwitchId | |
| CfprFabricVnetEpIfRole | |
| CfprFabricVnetEpLocale | |
| CfprFabricVnetEpPolicyOwner | |
| CfprFabricVnetEpSyncEpFsmCurrentFsm | |
| CfprFabricVnetEpSyncEpFsmStageName | |
| CfprFabricVnetEpSyncEpFsmTaskItem | |
| CfprFabricVsanOperState | |
| CfprFabricVsanSwitchId | |
| CfprFabricWarnings | |
| CfprFabricZoningState | |
| CfprFsmCompletion | |
| CfprFsmFlags | |
| CfprFsmFsmStageStatus | |
| CfprLicenseState | |
| CfprLsOperState | |
| CfprNetworkConnectionType | |
| CfprNetworkLocale | |
| CfprNetworkPortOperState | |
| CfprNetworkPortRole | |
| CfprNetworkSide | |
| CfprNetworkSwitchId | |
| CfprNetworkTransport | |
| CfprNetworkVnetEpIfType | |
| CfprNhTpHashType | |
| CfprPolicyPolicyOwner | |
| CfprPoolPoolAssignmentOrder | |
| CfprPortDuplex | |
| CfprPortEthAdminSpeed | |
| CfprPortEthSpeed | |
| CfprPortSpeed | |
| CfprQosPriority | |
| CfprSwPktCaptureLifeCycle |
From CISCO-SMI
| ciscoMgmt | OBJECT-IDENTITY |
From CISCO-TC
| CiscoAlarmSeverity | |
| CiscoInetAddressMask | |
| CiscoNetworkAddress | |
| TimeIntervalSec | |
| Unsigned64 |
From INET-ADDRESS-MIB
| InetAddressIPv4 | |
| InetAddressIPv6 |
From SNMP-FRAMEWORK-MIB
| SnmpAdminString |
From SNMPv2-SMI
| Counter32 | |
| Counter64 | |
| Gauge32 | |
| MODULE-IDENTITY | |
| OBJECT-TYPE | |
| TimeTicks | |
| Unsigned32 |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| MacAddress | |
| RowPointer | |
| TEXTUAL-CONVENTION | |
| TimeInterval | |
| TimeStamp | |
| TruthValue |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| cfprFabricObjects | 1.3.6.1.4.1.9.9.826.1.26 | MIB representation of the Cisco Firepower FABRIC management information model package | ||
| cfprFabricBHVlanTable | 1.3.6.1.4.1.9.9.826.1.26.1 | not-accessible | Cisco Firepower fabric:BHVlan managed object table | |
| cfprFabricBHVlanEntry | 1.3.6.1.4.1.9.9.826.1.26.1.1 | not-accessible | Entry for the cfprFabricBHVlanTable table. | |
| CFP cfprFabricBHVlanInstanceId | 1.3.6.1.4.1.9.9.826.1.26.1.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricBHVlanDn | 1.3.6.1.4.1.9.9.826.1.26.1.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:BHVlan:dn managed object property |
| STR cfprFabricBHVlanRn | 1.3.6.1.4.1.9.9.826.1.26.1.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:BHVlan:rn managed object property |
| CFP cfprFabricBHVlanAssocPrimaryVlanState | 1.3.6.1.4.1.9.9.826.1.26.1.1.4 | CfprFabricVlanAssocPrimaryVlanState | read-only | Cisco Firepower fabric:BHVlan:assocPrimaryVlanState managed object property |
| CFP cfprFabricBHVlanAssocPrimaryVlanSwitchId | 1.3.6.1.4.1.9.9.826.1.26.1.1.5 | CfprFabricAVlanAssocPrimaryVlanSwitchId | read-only | Cisco Firepower fabric:BHVlan:assocPrimaryVlanSwitchId managed object property |
| STR cfprFabricBHVlanEpDn | 1.3.6.1.4.1.9.9.826.1.26.1.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:BHVlan:epDn managed object property |
| G32 cfprFabricBHVlanId | 1.3.6.1.4.1.9.9.826.1.26.1.1.7 | Gauge32 | read-only | Cisco Firepower fabric:BHVlan:id managed object property |
| CFP cfprFabricBHVlanIfRole | 1.3.6.1.4.1.9.9.826.1.26.1.1.8 | CfprFabricVnetEpIfRole | read-only | Cisco Firepower fabric:BHVlan:ifRole managed object property |
| CFP cfprFabricBHVlanIfType | 1.3.6.1.4.1.9.9.826.1.26.1.1.9 | CfprNetworkVnetEpIfType | read-only | Cisco Firepower fabric:BHVlan:ifType managed object property |
| CFP cfprFabricBHVlanLocale | 1.3.6.1.4.1.9.9.826.1.26.1.1.10 | CfprFabricVnetEpLocale | read-only | Cisco Firepower fabric:BHVlan:locale managed object property |
| STR cfprFabricBHVlanName | 1.3.6.1.4.1.9.9.826.1.26.1.1.11 | SnmpAdminString | read-only | Cisco Firepower fabric:BHVlan:name managed object property |
| CFP cfprFabricBHVlanOperState | 1.3.6.1.4.1.9.9.826.1.26.1.1.12 | CfprFabricVlanOperState | read-only | Cisco Firepower fabric:BHVlan:operState managed object property |
| CFP cfprFabricBHVlanOverlapStateForA | 1.3.6.1.4.1.9.9.826.1.26.1.1.13 | CfprFabricVlanOverlapState | read-only | Cisco Firepower fabric:BHVlan:overlapStateForA managed object property |
| CFP cfprFabricBHVlanOverlapStateForB | 1.3.6.1.4.1.9.9.826.1.26.1.1.14 | CfprFabricVlanOverlapState | read-only | Cisco Firepower fabric:BHVlan:overlapStateForB managed object property |
| STR cfprFabricBHVlanPeerDn | 1.3.6.1.4.1.9.9.826.1.26.1.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:BHVlan:peerDn managed object property |
| CFP cfprFabricBHVlanPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.1.1.16 | CfprFabricVnetEpPolicyOwner | read-only | Cisco Firepower fabric:BHVlan:policyOwner managed object property |
| STR cfprFabricBHVlanPubNwDn | 1.3.6.1.4.1.9.9.826.1.26.1.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:BHVlan:pubNwDn managed object property |
| G32 cfprFabricBHVlanPubNwId | 1.3.6.1.4.1.9.9.826.1.26.1.1.18 | Gauge32 | read-only | Cisco Firepower fabric:BHVlan:pubNwId managed object property |
| STR cfprFabricBHVlanPubNwName | 1.3.6.1.4.1.9.9.826.1.26.1.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:BHVlan:pubNwName managed object property |
| CFP cfprFabricBHVlanSharing | 1.3.6.1.4.1.9.9.826.1.26.1.1.20 | CfprFabricAVlanSharing | read-only | Cisco Firepower fabric:BHVlan:sharing managed object property |
| CFP cfprFabricBHVlanSwitchId | 1.3.6.1.4.1.9.9.826.1.26.1.1.21 | CfprFabricBHVlanSwitchId | read-only | Cisco Firepower fabric:BHVlan:switchId managed object property |
| CFP cfprFabricBHVlanTransport | 1.3.6.1.4.1.9.9.826.1.26.1.1.22 | CfprFabricAVlanTransport | read-only | Cisco Firepower fabric:BHVlan:transport managed object property |
| CFP cfprFabricBHVlanType | 1.3.6.1.4.1.9.9.826.1.26.1.1.23 | CfprFabricAVlanType | read-only | Cisco Firepower fabric:BHVlan:type managed object property |
| cfprFabricBreakoutTable | 1.3.6.1.4.1.9.9.826.1.26.2 | not-accessible | Cisco Firepower fabric:Breakout managed object table | |
| cfprFabricBreakoutEntry | 1.3.6.1.4.1.9.9.826.1.26.2.1 | not-accessible | Entry for the cfprFabricBreakoutTable table. | |
| CFP cfprFabricBreakoutInstanceId | 1.3.6.1.4.1.9.9.826.1.26.2.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricBreakoutDn | 1.3.6.1.4.1.9.9.826.1.26.2.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:Breakout:dn managed object property |
| STR cfprFabricBreakoutRn | 1.3.6.1.4.1.9.9.826.1.26.2.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:Breakout:rn managed object property |
| CFP cfprFabricBreakoutBreakoutType | 1.3.6.1.4.1.9.9.826.1.26.2.1.4 | CfprFabricBreakoutType | read-only | Cisco Firepower fabric:Breakout:breakoutType managed object property |
| CFP cfprFabricBreakoutPortId | 1.3.6.1.4.1.9.9.826.1.26.2.1.5 | CfprFabricBreakoutPortId | read-only | Cisco Firepower fabric:Breakout:portId managed object property |
| CFP cfprFabricBreakoutSlotId | 1.3.6.1.4.1.9.9.826.1.26.2.1.6 | CfprFabricBreakoutSlotId | read-only | Cisco Firepower fabric:Breakout:slotId managed object property |
| cfprFabricCablingTable | 1.3.6.1.4.1.9.9.826.1.26.3 | not-accessible | Cisco Firepower fabric:Cabling managed object table | |
| cfprFabricCablingEntry | 1.3.6.1.4.1.9.9.826.1.26.3.1 | not-accessible | Entry for the cfprFabricCablingTable table. | |
| CFP cfprFabricCablingInstanceId | 1.3.6.1.4.1.9.9.826.1.26.3.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricCablingDn | 1.3.6.1.4.1.9.9.826.1.26.3.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:Cabling:dn managed object property |
| STR cfprFabricCablingRn | 1.3.6.1.4.1.9.9.826.1.26.3.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:Cabling:rn managed object property |
| cfprFabricCablingSwTable | 1.3.6.1.4.1.9.9.826.1.26.4 | not-accessible | Cisco Firepower fabric:CablingSw managed object table | |
| cfprFabricCablingSwEntry | 1.3.6.1.4.1.9.9.826.1.26.4.1 | not-accessible | Entry for the cfprFabricCablingSwTable table. | |
| CFP cfprFabricCablingSwInstanceId | 1.3.6.1.4.1.9.9.826.1.26.4.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricCablingSwDn | 1.3.6.1.4.1.9.9.826.1.26.4.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:CablingSw:dn managed object property |
| STR cfprFabricCablingSwRn | 1.3.6.1.4.1.9.9.826.1.26.4.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:CablingSw:rn managed object property |
| CFP cfprFabricCablingSwId | 1.3.6.1.4.1.9.9.826.1.26.4.1.4 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:CablingSw:id managed object property |
| CFP cfprFabricCablingSwLocale | 1.3.6.1.4.1.9.9.826.1.26.4.1.5 | CfprFabricExternalLocale | read-only | Cisco Firepower fabric:CablingSw:locale managed object property |
| STR cfprFabricCablingSwName | 1.3.6.1.4.1.9.9.826.1.26.4.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:CablingSw:name managed object property |
| CFP cfprFabricCablingSwTransport | 1.3.6.1.4.1.9.9.826.1.26.4.1.7 | CfprNetworkTransport | read-only | Cisco Firepower fabric:CablingSw:transport managed object property |
| CFP cfprFabricCablingSwType | 1.3.6.1.4.1.9.9.826.1.26.4.1.8 | CfprNetworkConnectionType | read-only | Cisco Firepower fabric:CablingSw:type managed object property |
| cfprFabricCdpLinkPolicyTable | 1.3.6.1.4.1.9.9.826.1.26.5 | not-accessible | Cisco Firepower fabric:CdpLinkPolicy managed object table | |
| cfprFabricCdpLinkPolicyEntry | 1.3.6.1.4.1.9.9.826.1.26.5.1 | not-accessible | Entry for the cfprFabricCdpLinkPolicyTable table. | |
| CFP cfprFabricCdpLinkPolicyInstanceId | 1.3.6.1.4.1.9.9.826.1.26.5.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricCdpLinkPolicyDn | 1.3.6.1.4.1.9.9.826.1.26.5.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:CdpLinkPolicy:dn managed object property |
| STR cfprFabricCdpLinkPolicyRn | 1.3.6.1.4.1.9.9.826.1.26.5.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:CdpLinkPolicy:rn managed object property |
| CFP cfprFabricCdpLinkPolicyAdminState | 1.3.6.1.4.1.9.9.826.1.26.5.1.4 | CfprFabricCdpLinkPolicyAdminState | read-only | Cisco Firepower fabric:CdpLinkPolicy:adminState managed object property |
| STR cfprFabricCdpLinkPolicyDescr | 1.3.6.1.4.1.9.9.826.1.26.5.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:CdpLinkPolicy:descr managed object property |
| STR cfprFabricCdpLinkPolicyIntId | 1.3.6.1.4.1.9.9.826.1.26.5.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:CdpLinkPolicy:intId managed object property |
| STR cfprFabricCdpLinkPolicyName | 1.3.6.1.4.1.9.9.826.1.26.5.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:CdpLinkPolicy:name managed object property |
| G32 cfprFabricCdpLinkPolicyPolicyLevel | 1.3.6.1.4.1.9.9.826.1.26.5.1.8 | Gauge32 | read-only | Cisco Firepower fabric:CdpLinkPolicy:policyLevel managed object property |
| CFP cfprFabricCdpLinkPolicyPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.5.1.9 | CfprPolicyPolicyOwner | read-only | Cisco Firepower fabric:CdpLinkPolicy:policyOwner managed object property |
| CFP cfprFabricCdpLinkPolicyProtocol | 1.3.6.1.4.1.9.9.826.1.26.5.1.10 | CfprFabricEthCdpPolicyProtocol | read-only | Cisco Firepower fabric:CdpLinkPolicy:protocol managed object property |
| CFP cfprFabricCdpLinkPolicyType | 1.3.6.1.4.1.9.9.826.1.26.5.1.11 | CfprFabricEthLinkPolicyType | read-only | Cisco Firepower fabric:CdpLinkPolicy:type managed object property |
| cfprFabricChangedObjectRefTable | 1.3.6.1.4.1.9.9.826.1.26.6 | not-accessible | Cisco Firepower fabric:ChangedObjectRef managed object table | |
| cfprFabricChangedObjectRefEntry | 1.3.6.1.4.1.9.9.826.1.26.6.1 | not-accessible | Entry for the cfprFabricChangedObjectRefTable table. | |
| CFP cfprFabricChangedObjectRefInstanceId | 1.3.6.1.4.1.9.9.826.1.26.6.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricChangedObjectRefDn | 1.3.6.1.4.1.9.9.826.1.26.6.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:ChangedObjectRef:dn managed object property |
| STR cfprFabricChangedObjectRefRn | 1.3.6.1.4.1.9.9.826.1.26.6.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:ChangedObjectRef:rn managed object property |
| STR cfprFabricChangedObjectRefCentraleVnetEpDn | 1.3.6.1.4.1.9.9.826.1.26.6.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:ChangedObjectRef:centraleVnetEpDn managed object property |
| G32 cfprFabricChangedObjectRefId | 1.3.6.1.4.1.9.9.826.1.26.6.1.5 | Gauge32 | read-only | Cisco Firepower fabric:ChangedObjectRef:id managed object property |
| STR cfprFabricChangedObjectRefOldCentraleVnetEpDn | 1.3.6.1.4.1.9.9.826.1.26.6.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:ChangedObjectRef:oldCentraleVnetEpDn managed object property |
| CFP cfprFabricChangedObjectRefRefObjStatus | 1.3.6.1.4.1.9.9.826.1.26.6.1.7 | CfprFabricStatus | read-only | Cisco Firepower fabric:ChangedObjectRef:refObjStatus managed object property |
| STR cfprFabricChangedObjectRefFprmVnetEpDn | 1.3.6.1.4.1.9.9.826.1.26.6.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:ChangedObjectRef:fprmVnetEpDn managed object property |
| cfprFabricChassisEpTable | 1.3.6.1.4.1.9.9.826.1.26.7 | not-accessible | Cisco Firepower fabric:ChassisEp managed object table | |
| cfprFabricChassisEpEntry | 1.3.6.1.4.1.9.9.826.1.26.7.1 | not-accessible | Entry for the cfprFabricChassisEpTable table. | |
| CFP cfprFabricChassisEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.7.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricChassisEpDn | 1.3.6.1.4.1.9.9.826.1.26.7.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:ChassisEp:dn managed object property |
| STR cfprFabricChassisEpRn | 1.3.6.1.4.1.9.9.826.1.26.7.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:ChassisEp:rn managed object property |
| NUM cfprFabricChassisEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.7.1.4 | CfprFabricInternalEpAdminState | read-only | Cisco Firepower fabric:ChassisEp:adminState managed object property |
| G32 cfprFabricChassisEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.7.1.5 | Gauge32 | read-only | Cisco Firepower fabric:ChassisEp:aggrPortId managed object property |
| STR cfprFabricChassisEpChassisDn | 1.3.6.1.4.1.9.9.826.1.26.7.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:ChassisEp:chassisDn managed object property |
| G32 cfprFabricChassisEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.7.1.7 | Gauge32 | read-only | Cisco Firepower fabric:ChassisEp:chassisId managed object property |
| STR cfprFabricChassisEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.7.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:ChassisEp:epDn managed object property |
| UNS cfprFabricChassisEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.7.1.9 | Unsigned64 | read-only | Cisco Firepower fabric:ChassisEp:fltAggr managed object property |
| CFP cfprFabricChassisEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.7.1.10 | CfprFabricComputeEpIfRole | read-only | Cisco Firepower fabric:ChassisEp:ifRole managed object property |
| CFP cfprFabricChassisEpIfType | 1.3.6.1.4.1.9.9.826.1.26.7.1.11 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:ChassisEp:ifType managed object property |
| UNS cfprFabricChassisEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.7.1.12 | Unsigned64 | read-only | Cisco Firepower fabric:ChassisEp:licGP managed object property |
| CFP cfprFabricChassisEpLicState | 1.3.6.1.4.1.9.9.826.1.26.7.1.13 | CfprLicenseState | read-only | Cisco Firepower fabric:ChassisEp:licState managed object property |
| NUM cfprFabricChassisEpLocale | 1.3.6.1.4.1.9.9.826.1.26.7.1.14 | CfprFabricInternalEpLocale | read-only | Cisco Firepower fabric:ChassisEp:locale managed object property |
| STR cfprFabricChassisEpModel | 1.3.6.1.4.1.9.9.826.1.26.7.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:ChassisEp:model managed object property |
| STR cfprFabricChassisEpName | 1.3.6.1.4.1.9.9.826.1.26.7.1.16 | SnmpAdminString | read-only | Cisco Firepower fabric:ChassisEp:name managed object property |
| CFP cfprFabricChassisEpOperState | 1.3.6.1.4.1.9.9.826.1.26.7.1.17 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:ChassisEp:operState managed object property |
| STR cfprFabricChassisEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.7.1.18 | SnmpAdminString | read-only | Cisco Firepower fabric:ChassisEp:operStateReason managed object property |
| G32 cfprFabricChassisEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.7.1.19 | Gauge32 | read-only | Cisco Firepower fabric:ChassisEp:peerAggrPortId managed object property |
| G32 cfprFabricChassisEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.7.1.20 | Gauge32 | read-only | Cisco Firepower fabric:ChassisEp:peerChassisId managed object property |
| STR cfprFabricChassisEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.7.1.21 | SnmpAdminString | read-only | Cisco Firepower fabric:ChassisEp:peerDn managed object property |
| G32 cfprFabricChassisEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.7.1.22 | Gauge32 | read-only | Cisco Firepower fabric:ChassisEp:peerPortId managed object property |
| G32 cfprFabricChassisEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.7.1.23 | Gauge32 | read-only | Cisco Firepower fabric:ChassisEp:peerSlotId managed object property |
| CFP cfprFabricChassisEpPortId | 1.3.6.1.4.1.9.9.826.1.26.7.1.24 | CfprFabricPIoEpPortId | read-only | Cisco Firepower fabric:ChassisEp:portId managed object property |
| STR cfprFabricChassisEpRevision | 1.3.6.1.4.1.9.9.826.1.26.7.1.25 | SnmpAdminString | read-only | Cisco Firepower fabric:ChassisEp:revision managed object property |
| STR cfprFabricChassisEpSerial | 1.3.6.1.4.1.9.9.826.1.26.7.1.26 | SnmpAdminString | read-only | Cisco Firepower fabric:ChassisEp:serial managed object property |
| CFP cfprFabricChassisEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.7.1.27 | CfprFabricPIoEpSlotId | read-only | Cisco Firepower fabric:ChassisEp:slotId managed object property |
| CFP cfprFabricChassisEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.7.1.28 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:ChassisEp:switchId managed object property |
| CFP cfprFabricChassisEpTransport | 1.3.6.1.4.1.9.9.826.1.26.7.1.29 | CfprNetworkTransport | read-only | Cisco Firepower fabric:ChassisEp:transport managed object property |
| CFP cfprFabricChassisEpType | 1.3.6.1.4.1.9.9.826.1.26.7.1.30 | CfprFabricComputeEpType | read-only | Cisco Firepower fabric:ChassisEp:type managed object property |
| STR cfprFabricChassisEpVendor | 1.3.6.1.4.1.9.9.826.1.26.7.1.31 | SnmpAdminString | read-only | Cisco Firepower fabric:ChassisEp:vendor managed object property |
| cfprFabricComputePhEpTable | 1.3.6.1.4.1.9.9.826.1.26.8 | not-accessible | Cisco Firepower fabric:ComputePhEp managed object table | |
| cfprFabricComputePhEpEntry | 1.3.6.1.4.1.9.9.826.1.26.8.1 | not-accessible | Entry for the cfprFabricComputePhEpTable table. | |
| CFP cfprFabricComputePhEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.8.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricComputePhEpDn | 1.3.6.1.4.1.9.9.826.1.26.8.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:ComputePhEp:dn managed object property |
| STR cfprFabricComputePhEpRn | 1.3.6.1.4.1.9.9.826.1.26.8.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputePhEp:rn managed object property |
| CFP cfprFabricComputePhEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.8.1.4 | CfprFabricComputePhEpAdminState | read-only | Cisco Firepower fabric:ComputePhEp:adminState managed object property |
| G32 cfprFabricComputePhEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.8.1.5 | Gauge32 | read-only | Cisco Firepower fabric:ComputePhEp:aggrPortId managed object property |
| CFP cfprFabricComputePhEpBoardAggregationRole | 1.3.6.1.4.1.9.9.826.1.26.8.1.6 | CfprEquipmentBoardAggregationRole | read-only | Cisco Firepower fabric:ComputePhEp:boardAggregationRole managed object property |
| G32 cfprFabricComputePhEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.8.1.7 | Gauge32 | read-only | Cisco Firepower fabric:ComputePhEp:chassisId managed object property |
| UNS cfprFabricComputePhEpCheckpointTrigTs | 1.3.6.1.4.1.9.9.826.1.26.8.1.8 | Unsigned64 | read-only | Cisco Firepower fabric:ComputePhEp:checkpointTrigTs managed object property |
| UNS cfprFabricComputePhEpDeepCheckpointTrigTs | 1.3.6.1.4.1.9.9.826.1.26.8.1.9 | Unsigned64 | read-only | Cisco Firepower fabric:ComputePhEp:deepCheckpointTrigTs managed object property |
| UNS cfprFabricComputePhEpDiscTrigTs | 1.3.6.1.4.1.9.9.826.1.26.8.1.10 | Unsigned64 | read-only | Cisco Firepower fabric:ComputePhEp:discTrigTs managed object property |
| STR cfprFabricComputePhEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.8.1.11 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputePhEp:epDn managed object property |
| CFP cfprFabricComputePhEpEqType | 1.3.6.1.4.1.9.9.826.1.26.8.1.12 | CfprEquipmentFabricEpType | read-only | Cisco Firepower fabric:ComputePhEp:eqType managed object property |
| UNS cfprFabricComputePhEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.8.1.13 | Unsigned64 | read-only | Cisco Firepower fabric:ComputePhEp:fltAggr managed object property |
| CFP cfprFabricComputePhEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.8.1.14 | CfprFabricComputeEpIfRole | read-only | Cisco Firepower fabric:ComputePhEp:ifRole managed object property |
| CFP cfprFabricComputePhEpIfType | 1.3.6.1.4.1.9.9.826.1.26.8.1.15 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:ComputePhEp:ifType managed object property |
| CFP cfprFabricComputePhEpLc | 1.3.6.1.4.1.9.9.826.1.26.8.1.16 | CfprFabricBladeLifeCycle | read-only | Cisco Firepower fabric:ComputePhEp:lc managed object property |
| UNS cfprFabricComputePhEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.8.1.17 | Unsigned64 | read-only | Cisco Firepower fabric:ComputePhEp:licGP managed object property |
| CFP cfprFabricComputePhEpLicState | 1.3.6.1.4.1.9.9.826.1.26.8.1.18 | CfprLicenseState | read-only | Cisco Firepower fabric:ComputePhEp:licState managed object property |
| NUM cfprFabricComputePhEpLocale | 1.3.6.1.4.1.9.9.826.1.26.8.1.19 | CfprFabricInternalEpLocale | read-only | Cisco Firepower fabric:ComputePhEp:locale managed object property |
| STR cfprFabricComputePhEpModel | 1.3.6.1.4.1.9.9.826.1.26.8.1.20 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputePhEp:model managed object property |
| STR cfprFabricComputePhEpName | 1.3.6.1.4.1.9.9.826.1.26.8.1.21 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputePhEp:name managed object property |
| CFP cfprFabricComputePhEpOperState | 1.3.6.1.4.1.9.9.826.1.26.8.1.22 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:ComputePhEp:operState managed object property |
| STR cfprFabricComputePhEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.8.1.23 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputePhEp:operStateReason managed object property |
| G32 cfprFabricComputePhEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.8.1.24 | Gauge32 | read-only | Cisco Firepower fabric:ComputePhEp:peerAggrPortId managed object property |
| G32 cfprFabricComputePhEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.8.1.25 | Gauge32 | read-only | Cisco Firepower fabric:ComputePhEp:peerChassisId managed object property |
| STR cfprFabricComputePhEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.8.1.26 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputePhEp:peerDn managed object property |
| G32 cfprFabricComputePhEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.8.1.27 | Gauge32 | read-only | Cisco Firepower fabric:ComputePhEp:peerPortId managed object property |
| G32 cfprFabricComputePhEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.8.1.28 | Gauge32 | read-only | Cisco Firepower fabric:ComputePhEp:peerSlotId managed object property |
| CFP cfprFabricComputePhEpPortId | 1.3.6.1.4.1.9.9.826.1.26.8.1.29 | CfprFabricPIoEpPortId | read-only | Cisco Firepower fabric:ComputePhEp:portId managed object property |
| STR cfprFabricComputePhEpProfileDn | 1.3.6.1.4.1.9.9.826.1.26.8.1.30 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputePhEp:profileDn managed object property |
| STR cfprFabricComputePhEpRevision | 1.3.6.1.4.1.9.9.826.1.26.8.1.31 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputePhEp:revision managed object property |
| STR cfprFabricComputePhEpSerial | 1.3.6.1.4.1.9.9.826.1.26.8.1.32 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputePhEp:serial managed object property |
| CFP cfprFabricComputePhEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.8.1.33 | CfprFabricPIoEpSlotId | read-only | Cisco Firepower fabric:ComputePhEp:slotId managed object property |
| CFP cfprFabricComputePhEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.8.1.34 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:ComputePhEp:switchId managed object property |
| CFP cfprFabricComputePhEpTransport | 1.3.6.1.4.1.9.9.826.1.26.8.1.35 | CfprNetworkTransport | read-only | Cisco Firepower fabric:ComputePhEp:transport managed object property |
| CFP cfprFabricComputePhEpType | 1.3.6.1.4.1.9.9.826.1.26.8.1.36 | CfprFabricComputeEpType | read-only | Cisco Firepower fabric:ComputePhEp:type managed object property |
| STR cfprFabricComputePhEpVendor | 1.3.6.1.4.1.9.9.826.1.26.8.1.37 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputePhEp:vendor managed object property |
| cfprFabricComputeSlotEpTable | 1.3.6.1.4.1.9.9.826.1.26.9 | not-accessible | Cisco Firepower fabric:ComputeSlotEp managed object table | |
| cfprFabricComputeSlotEpEntry | 1.3.6.1.4.1.9.9.826.1.26.9.1 | not-accessible | Entry for the cfprFabricComputeSlotEpTable table. | |
| CFP cfprFabricComputeSlotEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.9.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricComputeSlotEpDn | 1.3.6.1.4.1.9.9.826.1.26.9.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:ComputeSlotEp:dn managed object property |
| STR cfprFabricComputeSlotEpRn | 1.3.6.1.4.1.9.9.826.1.26.9.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:rn managed object property |
| CFP cfprFabricComputeSlotEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.9.1.4 | CfprFabricSlotAdminState | read-only | Cisco Firepower fabric:ComputeSlotEp:adminState managed object property |
| G32 cfprFabricComputeSlotEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.9.1.5 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEp:aggrPortId managed object property |
| CFP cfprFabricComputeSlotEpBoardAggregationRole | 1.3.6.1.4.1.9.9.826.1.26.9.1.6 | CfprEquipmentBoardAggregationRole | read-only | Cisco Firepower fabric:ComputeSlotEp:boardAggregationRole managed object property |
| G32 cfprFabricComputeSlotEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.9.1.7 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEp:chassisId managed object property |
| CFP cfprFabricComputeSlotEpConnPath | 1.3.6.1.4.1.9.9.826.1.26.9.1.8 | CfprEquipmentConnectionStatus | read-only | Cisco Firepower fabric:ComputeSlotEp:connPath managed object property |
| CFP cfprFabricComputeSlotEpConnStatus | 1.3.6.1.4.1.9.9.826.1.26.9.1.9 | CfprEquipmentConnectionStatus | read-only | Cisco Firepower fabric:ComputeSlotEp:connStatus managed object property |
| CFP cfprFabricComputeSlotEpDiscovery | 1.3.6.1.4.1.9.9.826.1.26.9.1.10 | CfprComputeDiscovery | read-only | Cisco Firepower fabric:ComputeSlotEp:discovery managed object property |
| STR cfprFabricComputeSlotEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.9.1.11 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:epDn managed object property |
| T/F cfprFabricComputeSlotEpFactoryResetFlag | 1.3.6.1.4.1.9.9.826.1.26.9.1.12 | TruthValue | read-only | Cisco Firepower fabric:ComputeSlotEp:factoryResetFlag managed object property |
| UNS cfprFabricComputeSlotEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.9.1.13 | Unsigned64 | read-only | Cisco Firepower fabric:ComputeSlotEp:fltAggr managed object property |
| UNS cfprFabricComputeSlotEpFruIdentTrigTs | 1.3.6.1.4.1.9.9.826.1.26.9.1.14 | Unsigned64 | read-only | Cisco Firepower fabric:ComputeSlotEp:fruIdentTrigTs managed object property |
| STR cfprFabricComputeSlotEpFsmDescr | 1.3.6.1.4.1.9.9.826.1.26.9.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:fsmDescr managed object property |
| STR cfprFabricComputeSlotEpFsmPrev | 1.3.6.1.4.1.9.9.826.1.26.9.1.16 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:fsmPrev managed object property |
| G32 cfprFabricComputeSlotEpFsmProgr | 1.3.6.1.4.1.9.9.826.1.26.9.1.17 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEp:fsmProgr managed object property |
| G32 cfprFabricComputeSlotEpFsmRmtInvErrCode | 1.3.6.1.4.1.9.9.826.1.26.9.1.18 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEp:fsmRmtInvErrCode managed object property |
| STR cfprFabricComputeSlotEpFsmRmtInvErrDescr | 1.3.6.1.4.1.9.9.826.1.26.9.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:fsmRmtInvErrDescr managed object property |
| CFP cfprFabricComputeSlotEpFsmRmtInvRslt | 1.3.6.1.4.1.9.9.826.1.26.9.1.20 | CfprConditionRemoteInvRslt | read-only | Cisco Firepower fabric:ComputeSlotEp:fsmRmtInvRslt managed object property |
| STR cfprFabricComputeSlotEpFsmStageDescr | 1.3.6.1.4.1.9.9.826.1.26.9.1.21 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:fsmStageDescr managed object property |
| DAT cfprFabricComputeSlotEpFsmStamp | 1.3.6.1.4.1.9.9.826.1.26.9.1.22 | DateAndTime | read-only | Cisco Firepower fabric:ComputeSlotEp:fsmStamp managed object property |
| STR cfprFabricComputeSlotEpFsmStatus | 1.3.6.1.4.1.9.9.826.1.26.9.1.23 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:fsmStatus managed object property |
| G32 cfprFabricComputeSlotEpFsmTry | 1.3.6.1.4.1.9.9.826.1.26.9.1.24 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEp:fsmTry managed object property |
| CFP cfprFabricComputeSlotEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.9.1.25 | CfprFabricComputeEpIfRole | read-only | Cisco Firepower fabric:ComputeSlotEp:ifRole managed object property |
| CFP cfprFabricComputeSlotEpIfType | 1.3.6.1.4.1.9.9.826.1.26.9.1.26 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:ComputeSlotEp:ifType managed object property |
| DAT cfprFabricComputeSlotEpLcTs | 1.3.6.1.4.1.9.9.826.1.26.9.1.27 | DateAndTime | read-only | Cisco Firepower fabric:ComputeSlotEp:lcTs managed object property |
| UNS cfprFabricComputeSlotEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.9.1.28 | Unsigned64 | read-only | Cisco Firepower fabric:ComputeSlotEp:licGP managed object property |
| CFP cfprFabricComputeSlotEpLicState | 1.3.6.1.4.1.9.9.826.1.26.9.1.29 | CfprLicenseState | read-only | Cisco Firepower fabric:ComputeSlotEp:licState managed object property |
| NUM cfprFabricComputeSlotEpLocale | 1.3.6.1.4.1.9.9.826.1.26.9.1.30 | CfprFabricInternalEpLocale | read-only | Cisco Firepower fabric:ComputeSlotEp:locale managed object property |
| CFP cfprFabricComputeSlotEpManagingInst | 1.3.6.1.4.1.9.9.826.1.26.9.1.31 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:ComputeSlotEp:managingInst managed object property |
| STR cfprFabricComputeSlotEpModel | 1.3.6.1.4.1.9.9.826.1.26.9.1.32 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:model managed object property |
| STR cfprFabricComputeSlotEpName | 1.3.6.1.4.1.9.9.826.1.26.9.1.33 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:name managed object property |
| CFP cfprFabricComputeSlotEpOperState | 1.3.6.1.4.1.9.9.826.1.26.9.1.34 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:ComputeSlotEp:operState managed object property |
| STR cfprFabricComputeSlotEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.9.1.35 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:operStateReason managed object property |
| G32 cfprFabricComputeSlotEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.9.1.36 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEp:peerAggrPortId managed object property |
| G32 cfprFabricComputeSlotEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.9.1.37 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEp:peerChassisId managed object property |
| STR cfprFabricComputeSlotEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.9.1.38 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:peerDn managed object property |
| G32 cfprFabricComputeSlotEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.9.1.39 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEp:peerPortId managed object property |
| STR cfprFabricComputeSlotEpPeerSlotEpDn | 1.3.6.1.4.1.9.9.826.1.26.9.1.40 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:peerSlotEpDn managed object property |
| G32 cfprFabricComputeSlotEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.9.1.41 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEp:peerSlotId managed object property |
| CFP cfprFabricComputeSlotEpPortId | 1.3.6.1.4.1.9.9.826.1.26.9.1.42 | CfprFabricPIoEpPortId | read-only | Cisco Firepower fabric:ComputeSlotEp:portId managed object property |
| CFP cfprFabricComputeSlotEpPresence | 1.3.6.1.4.1.9.9.826.1.26.9.1.43 | CfprEquipmentSlotStatus | read-only | Cisco Firepower fabric:ComputeSlotEp:presence managed object property |
| CFP cfprFabricComputeSlotEpPresencePath | 1.3.6.1.4.1.9.9.826.1.26.9.1.44 | CfprEquipmentConnectionStatus | read-only | Cisco Firepower fabric:ComputeSlotEp:presencePath managed object property |
| STR cfprFabricComputeSlotEpRevision | 1.3.6.1.4.1.9.9.826.1.26.9.1.45 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:revision managed object property |
| STR cfprFabricComputeSlotEpSerial | 1.3.6.1.4.1.9.9.826.1.26.9.1.46 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:serial managed object property |
| CFP cfprFabricComputeSlotEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.9.1.47 | CfprFabricComputeSlotEpSlotId | read-only | Cisco Firepower fabric:ComputeSlotEp:slotId managed object property |
| CFP cfprFabricComputeSlotEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.9.1.48 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:ComputeSlotEp:switchId managed object property |
| CFP cfprFabricComputeSlotEpTransport | 1.3.6.1.4.1.9.9.826.1.26.9.1.49 | CfprNetworkTransport | read-only | Cisco Firepower fabric:ComputeSlotEp:transport managed object property |
| CFP cfprFabricComputeSlotEpType | 1.3.6.1.4.1.9.9.826.1.26.9.1.50 | CfprFabricComputeEpType | read-only | Cisco Firepower fabric:ComputeSlotEp:type managed object property |
| STR cfprFabricComputeSlotEpVendor | 1.3.6.1.4.1.9.9.826.1.26.9.1.51 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:vendor managed object property |
| CFP cfprFabricComputeSlotEpBladeState | 1.3.6.1.4.1.9.9.826.1.26.9.1.52 | CfprLsOperState | read-only | Cisco Firepower fabric:ComputeSlotEp:bladeState managed object property |
| CFP cfprFabricComputeSlotEpDecommissionSecure | 1.3.6.1.4.1.9.9.826.1.26.9.1.53 | CfprComputeDecommissionState | read-only | Cisco Firepower fabric:ComputeSlotEp:decommissionSecure managed object property |
| STR cfprFabricComputeSlotEpFailReason | 1.3.6.1.4.1.9.9.826.1.26.9.1.54 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEp:failReason managed object property |
| cfprFabricComputeSlotEpFsmTable | 1.3.6.1.4.1.9.9.826.1.26.10 | not-accessible | Cisco Firepower fabric:ComputeSlotEpFsm managed object table | |
| cfprFabricComputeSlotEpFsmEntry | 1.3.6.1.4.1.9.9.826.1.26.10.1 | not-accessible | Entry for the cfprFabricComputeSlotEpFsmTable table. | |
| CFP cfprFabricComputeSlotEpFsmInstanceId | 1.3.6.1.4.1.9.9.826.1.26.10.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricComputeSlotEpFsmDn | 1.3.6.1.4.1.9.9.826.1.26.10.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:ComputeSlotEpFsm:dn managed object property |
| STR cfprFabricComputeSlotEpFsmRn | 1.3.6.1.4.1.9.9.826.1.26.10.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEpFsm:rn managed object property |
| DAT cfprFabricComputeSlotEpFsmCompletionTime | 1.3.6.1.4.1.9.9.826.1.26.10.1.4 | DateAndTime | read-only | Cisco Firepower fabric:ComputeSlotEpFsm:completionTime managed object property |
| CFP cfprFabricComputeSlotEpFsmCurrentFsm | 1.3.6.1.4.1.9.9.826.1.26.10.1.5 | CfprFabricComputeSlotEpFsmCurrentFsm | read-only | Cisco Firepower fabric:ComputeSlotEpFsm:currentFsm managed object property |
| STR cfprFabricComputeSlotEpFsmDescrData | 1.3.6.1.4.1.9.9.826.1.26.10.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEpFsm:descr managed object property |
| CFP cfprFabricComputeSlotEpFsmFsmStatus | 1.3.6.1.4.1.9.9.826.1.26.10.1.7 | CfprFsmFsmStageStatus | read-only | Cisco Firepower fabric:ComputeSlotEpFsm:fsmStatus managed object property |
| G32 cfprFabricComputeSlotEpFsmProgress | 1.3.6.1.4.1.9.9.826.1.26.10.1.8 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEpFsm:progress managed object property |
| G32 cfprFabricComputeSlotEpFsmRmtErrCode | 1.3.6.1.4.1.9.9.826.1.26.10.1.9 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEpFsm:rmtErrCode managed object property |
| STR cfprFabricComputeSlotEpFsmRmtErrDescr | 1.3.6.1.4.1.9.9.826.1.26.10.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEpFsm:rmtErrDescr managed object property |
| CFP cfprFabricComputeSlotEpFsmRmtRslt | 1.3.6.1.4.1.9.9.826.1.26.10.1.11 | CfprConditionRemoteInvRslt | read-only | Cisco Firepower fabric:ComputeSlotEpFsm:rmtRslt managed object property |
| cfprFabricComputeSlotEpFsmStageTable | 1.3.6.1.4.1.9.9.826.1.26.11 | not-accessible | Cisco Firepower fabric:ComputeSlotEpFsmStage managed object table | |
| cfprFabricComputeSlotEpFsmStageEntry | 1.3.6.1.4.1.9.9.826.1.26.11.1 | not-accessible | Entry for the cfprFabricComputeSlotEpFsmStageTable table. | |
| CFP cfprFabricComputeSlotEpFsmStageInstanceId | 1.3.6.1.4.1.9.9.826.1.26.11.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricComputeSlotEpFsmStageDn | 1.3.6.1.4.1.9.9.826.1.26.11.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:ComputeSlotEpFsmStage:dn managed object property |
| STR cfprFabricComputeSlotEpFsmStageRn | 1.3.6.1.4.1.9.9.826.1.26.11.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEpFsmStage:rn managed object property |
| STR cfprFabricComputeSlotEpFsmStageDescrData | 1.3.6.1.4.1.9.9.826.1.26.11.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEpFsmStage:descr managed object property |
| DAT cfprFabricComputeSlotEpFsmStageLastUpdateTime | 1.3.6.1.4.1.9.9.826.1.26.11.1.5 | DateAndTime | read-only | Cisco Firepower fabric:ComputeSlotEpFsmStage:lastUpdateTime managed object property |
| CFP cfprFabricComputeSlotEpFsmStageName | 1.3.6.1.4.1.9.9.826.1.26.11.1.6 | CfprFabricComputeSlotEpFsmStageName | read-only | Cisco Firepower fabric:ComputeSlotEpFsmStage:name managed object property |
| G32 cfprFabricComputeSlotEpFsmStageOrder | 1.3.6.1.4.1.9.9.826.1.26.11.1.7 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEpFsmStage:order managed object property |
| G32 cfprFabricComputeSlotEpFsmStageRetry | 1.3.6.1.4.1.9.9.826.1.26.11.1.8 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEpFsmStage:retry managed object property |
| CFP cfprFabricComputeSlotEpFsmStageStageStatus | 1.3.6.1.4.1.9.9.826.1.26.11.1.9 | CfprFsmFsmStageStatus | read-only | Cisco Firepower fabric:ComputeSlotEpFsmStage:stageStatus managed object property |
| cfprFabricComputeSlotEpFsmTaskTable | 1.3.6.1.4.1.9.9.826.1.26.12 | not-accessible | Cisco Firepower fabric:ComputeSlotEpFsmTask managed object table | |
| cfprFabricComputeSlotEpFsmTaskEntry | 1.3.6.1.4.1.9.9.826.1.26.12.1 | not-accessible | Entry for the cfprFabricComputeSlotEpFsmTaskTable table. | |
| CFP cfprFabricComputeSlotEpFsmTaskInstanceId | 1.3.6.1.4.1.9.9.826.1.26.12.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricComputeSlotEpFsmTaskDn | 1.3.6.1.4.1.9.9.826.1.26.12.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:ComputeSlotEpFsmTask:dn managed object property |
| STR cfprFabricComputeSlotEpFsmTaskRn | 1.3.6.1.4.1.9.9.826.1.26.12.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:ComputeSlotEpFsmTask:rn managed object property |
| CFP cfprFabricComputeSlotEpFsmTaskCompletion | 1.3.6.1.4.1.9.9.826.1.26.12.1.4 | CfprFsmCompletion | read-only | Cisco Firepower fabric:ComputeSlotEpFsmTask:completion managed object property |
| CFP cfprFabricComputeSlotEpFsmTaskFlags | 1.3.6.1.4.1.9.9.826.1.26.12.1.5 | CfprFsmFlags | read-only | Cisco Firepower fabric:ComputeSlotEpFsmTask:flags managed object property |
| CFP cfprFabricComputeSlotEpFsmTaskItem | 1.3.6.1.4.1.9.9.826.1.26.12.1.6 | CfprFabricComputeSlotEpFsmTaskItem | read-only | Cisco Firepower fabric:ComputeSlotEpFsmTask:item managed object property |
| G32 cfprFabricComputeSlotEpFsmTaskSeqId | 1.3.6.1.4.1.9.9.826.1.26.12.1.7 | Gauge32 | read-only | Cisco Firepower fabric:ComputeSlotEpFsmTask:seqId managed object property |
| cfprFabricDceSrvTable | 1.3.6.1.4.1.9.9.826.1.26.13 | not-accessible | Cisco Firepower fabric:DceSrv managed object table | |
| cfprFabricDceSrvEntry | 1.3.6.1.4.1.9.9.826.1.26.13.1 | not-accessible | Entry for the cfprFabricDceSrvTable table. | |
| CFP cfprFabricDceSrvInstanceId | 1.3.6.1.4.1.9.9.826.1.26.13.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricDceSrvDn | 1.3.6.1.4.1.9.9.826.1.26.13.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:DceSrv:dn managed object property |
| STR cfprFabricDceSrvRn | 1.3.6.1.4.1.9.9.826.1.26.13.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSrv:rn managed object property |
| CFP cfprFabricDceSrvId | 1.3.6.1.4.1.9.9.826.1.26.13.1.4 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:DceSrv:id managed object property |
| NUM cfprFabricDceSrvLocale | 1.3.6.1.4.1.9.9.826.1.26.13.1.5 | CfprFabricInternalLocale | read-only | Cisco Firepower fabric:DceSrv:locale managed object property |
| STR cfprFabricDceSrvName | 1.3.6.1.4.1.9.9.826.1.26.13.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSrv:name managed object property |
| NUM cfprFabricDceSrvTransport | 1.3.6.1.4.1.9.9.826.1.26.13.1.7 | CfprFabricInternalDceSrvTransport | read-only | Cisco Firepower fabric:DceSrv:transport managed object property |
| NUM cfprFabricDceSrvType | 1.3.6.1.4.1.9.9.826.1.26.13.1.8 | CfprFabricInternalDceSrvType | read-only | Cisco Firepower fabric:DceSrv:type managed object property |
| cfprFabricDceSwSrvTable | 1.3.6.1.4.1.9.9.826.1.26.14 | not-accessible | Cisco Firepower fabric:DceSwSrv managed object table | |
| cfprFabricDceSwSrvEntry | 1.3.6.1.4.1.9.9.826.1.26.14.1 | not-accessible | Entry for the cfprFabricDceSwSrvTable table. | |
| CFP cfprFabricDceSwSrvInstanceId | 1.3.6.1.4.1.9.9.826.1.26.14.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricDceSwSrvDn | 1.3.6.1.4.1.9.9.826.1.26.14.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:DceSwSrv:dn managed object property |
| STR cfprFabricDceSwSrvRn | 1.3.6.1.4.1.9.9.826.1.26.14.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrv:rn managed object property |
| CFP cfprFabricDceSwSrvId | 1.3.6.1.4.1.9.9.826.1.26.14.1.4 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:DceSwSrv:id managed object property |
| NUM cfprFabricDceSwSrvLocale | 1.3.6.1.4.1.9.9.826.1.26.14.1.5 | CfprFabricInternalLocale | read-only | Cisco Firepower fabric:DceSwSrv:locale managed object property |
| STR cfprFabricDceSwSrvName | 1.3.6.1.4.1.9.9.826.1.26.14.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrv:name managed object property |
| NUM cfprFabricDceSwSrvTransport | 1.3.6.1.4.1.9.9.826.1.26.14.1.7 | CfprFabricInternalDceSrvTransport | read-only | Cisco Firepower fabric:DceSwSrv:transport managed object property |
| NUM cfprFabricDceSwSrvType | 1.3.6.1.4.1.9.9.826.1.26.14.1.8 | CfprFabricInternalDceSrvType | read-only | Cisco Firepower fabric:DceSwSrv:type managed object property |
| cfprFabricDceSwSrvEpTable | 1.3.6.1.4.1.9.9.826.1.26.15 | not-accessible | Cisco Firepower fabric:DceSwSrvEp managed object table | |
| cfprFabricDceSwSrvEpEntry | 1.3.6.1.4.1.9.9.826.1.26.15.1 | not-accessible | Entry for the cfprFabricDceSwSrvEpTable table. | |
| CFP cfprFabricDceSwSrvEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.15.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricDceSwSrvEpDn | 1.3.6.1.4.1.9.9.826.1.26.15.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:DceSwSrvEp:dn managed object property |
| STR cfprFabricDceSwSrvEpRn | 1.3.6.1.4.1.9.9.826.1.26.15.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvEp:rn managed object property |
| NUM cfprFabricDceSwSrvEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.15.1.4 | CfprFabricInternalEpAdminState | read-only | Cisco Firepower fabric:DceSwSrvEp:adminState managed object property |
| G32 cfprFabricDceSwSrvEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.15.1.5 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvEp:aggrPortId managed object property |
| G32 cfprFabricDceSwSrvEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.15.1.6 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvEp:chassisId managed object property |
| STR cfprFabricDceSwSrvEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.15.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvEp:epDn managed object property |
| UNS cfprFabricDceSwSrvEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.15.1.8 | Unsigned64 | read-only | Cisco Firepower fabric:DceSwSrvEp:fltAggr managed object property |
| CFP cfprFabricDceSwSrvEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.15.1.9 | CfprFabricSwSrvEpIfRole | read-only | Cisco Firepower fabric:DceSwSrvEp:ifRole managed object property |
| CFP cfprFabricDceSwSrvEpIfType | 1.3.6.1.4.1.9.9.826.1.26.15.1.10 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:DceSwSrvEp:ifType managed object property |
| UNS cfprFabricDceSwSrvEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.15.1.11 | Unsigned64 | read-only | Cisco Firepower fabric:DceSwSrvEp:licGP managed object property |
| CFP cfprFabricDceSwSrvEpLicState | 1.3.6.1.4.1.9.9.826.1.26.15.1.12 | CfprLicenseState | read-only | Cisco Firepower fabric:DceSwSrvEp:licState managed object property |
| NUM cfprFabricDceSwSrvEpLocale | 1.3.6.1.4.1.9.9.826.1.26.15.1.13 | CfprFabricInternalEpLocale | read-only | Cisco Firepower fabric:DceSwSrvEp:locale managed object property |
| STR cfprFabricDceSwSrvEpName | 1.3.6.1.4.1.9.9.826.1.26.15.1.14 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvEp:name managed object property |
| CFP cfprFabricDceSwSrvEpOperState | 1.3.6.1.4.1.9.9.826.1.26.15.1.15 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:DceSwSrvEp:operState managed object property |
| STR cfprFabricDceSwSrvEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.15.1.16 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvEp:operStateReason managed object property |
| G32 cfprFabricDceSwSrvEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.15.1.17 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvEp:peerAggrPortId managed object property |
| G32 cfprFabricDceSwSrvEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.15.1.18 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvEp:peerChassisId managed object property |
| STR cfprFabricDceSwSrvEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.15.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvEp:peerDn managed object property |
| G32 cfprFabricDceSwSrvEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.15.1.20 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvEp:peerPortId managed object property |
| G32 cfprFabricDceSwSrvEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.15.1.21 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvEp:peerSlotId managed object property |
| CFP cfprFabricDceSwSrvEpPortId | 1.3.6.1.4.1.9.9.826.1.26.15.1.22 | CfprFabricDceSwSrvEpPortId | read-only | Cisco Firepower fabric:DceSwSrvEp:portId managed object property |
| CFP cfprFabricDceSwSrvEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.15.1.23 | CfprFabricDceSwSrvEpSlotId | read-only | Cisco Firepower fabric:DceSwSrvEp:slotId managed object property |
| CFP cfprFabricDceSwSrvEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.15.1.24 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:DceSwSrvEp:switchId managed object property |
| CFP cfprFabricDceSwSrvEpTransport | 1.3.6.1.4.1.9.9.826.1.26.15.1.25 | CfprFabricADceSwSrvEpTransport | read-only | Cisco Firepower fabric:DceSwSrvEp:transport managed object property |
| CFP cfprFabricDceSwSrvEpType | 1.3.6.1.4.1.9.9.826.1.26.15.1.26 | CfprFabricSwSrvEpType | read-only | Cisco Firepower fabric:DceSwSrvEp:type managed object property |
| STR cfprFabricDceSwSrvEpUsrLbl | 1.3.6.1.4.1.9.9.826.1.26.15.1.27 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvEp:usrLbl managed object property |
| cfprFabricDceSwSrvPcTable | 1.3.6.1.4.1.9.9.826.1.26.16 | not-accessible | Cisco Firepower fabric:DceSwSrvPc managed object table | |
| cfprFabricDceSwSrvPcEntry | 1.3.6.1.4.1.9.9.826.1.26.16.1 | not-accessible | Entry for the cfprFabricDceSwSrvPcTable table. | |
| CFP cfprFabricDceSwSrvPcInstanceId | 1.3.6.1.4.1.9.9.826.1.26.16.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricDceSwSrvPcDn | 1.3.6.1.4.1.9.9.826.1.26.16.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:DceSwSrvPc:dn managed object property |
| STR cfprFabricDceSwSrvPcRn | 1.3.6.1.4.1.9.9.826.1.26.16.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvPc:rn managed object property |
| CFP cfprFabricDceSwSrvPcAdminState | 1.3.6.1.4.1.9.9.826.1.26.16.1.4 | CfprFabricDceSwSrvPcAdminState | read-only | Cisco Firepower fabric:DceSwSrvPc:adminState managed object property |
| G32 cfprFabricDceSwSrvPcChassisId | 1.3.6.1.4.1.9.9.826.1.26.16.1.5 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvPc:chassisId managed object property |
| STR cfprFabricDceSwSrvPcDescr | 1.3.6.1.4.1.9.9.826.1.26.16.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvPc:descr managed object property |
| STR cfprFabricDceSwSrvPcEpDn | 1.3.6.1.4.1.9.9.826.1.26.16.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvPc:epDn managed object property |
| UNS cfprFabricDceSwSrvPcFltAggr | 1.3.6.1.4.1.9.9.826.1.26.16.1.8 | Unsigned64 | read-only | Cisco Firepower fabric:DceSwSrvPc:fltAggr managed object property |
| CFP cfprFabricDceSwSrvPcIfRole | 1.3.6.1.4.1.9.9.826.1.26.16.1.9 | CfprFabricSwSrvPcIfRole | read-only | Cisco Firepower fabric:DceSwSrvPc:ifRole managed object property |
| CFP cfprFabricDceSwSrvPcIfType | 1.3.6.1.4.1.9.9.826.1.26.16.1.10 | CfprFabricCIoEpIfType | read-only | Cisco Firepower fabric:DceSwSrvPc:ifType managed object property |
| NUM cfprFabricDceSwSrvPcLocale | 1.3.6.1.4.1.9.9.826.1.26.16.1.11 | CfprFabricInternalPcLocale | read-only | Cisco Firepower fabric:DceSwSrvPc:locale managed object property |
| STR cfprFabricDceSwSrvPcName | 1.3.6.1.4.1.9.9.826.1.26.16.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvPc:name managed object property |
| CFP cfprFabricDceSwSrvPcOperSpeed | 1.3.6.1.4.1.9.9.826.1.26.16.1.13 | CfprPortEthSpeed | read-only | Cisco Firepower fabric:DceSwSrvPc:operSpeed managed object property |
| CFP cfprFabricDceSwSrvPcOperState | 1.3.6.1.4.1.9.9.826.1.26.16.1.14 | CfprNetworkPortOperState | read-only | Cisco Firepower fabric:DceSwSrvPc:operState managed object property |
| STR cfprFabricDceSwSrvPcPeerDn | 1.3.6.1.4.1.9.9.826.1.26.16.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvPc:peerDn managed object property |
| CFP cfprFabricDceSwSrvPcPortId | 1.3.6.1.4.1.9.9.826.1.26.16.1.16 | CfprFabricDceSwSrvPcPortId | read-only | Cisco Firepower fabric:DceSwSrvPc:portId managed object property |
| STR cfprFabricDceSwSrvPcStateQual | 1.3.6.1.4.1.9.9.826.1.26.16.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvPc:stateQual managed object property |
| CFP cfprFabricDceSwSrvPcSwitchId | 1.3.6.1.4.1.9.9.826.1.26.16.1.18 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:DceSwSrvPc:switchId managed object property |
| CFP cfprFabricDceSwSrvPcTransport | 1.3.6.1.4.1.9.9.826.1.26.16.1.19 | CfprFabricDceSwSrvPcTransport | read-only | Cisco Firepower fabric:DceSwSrvPc:transport managed object property |
| CFP cfprFabricDceSwSrvPcType | 1.3.6.1.4.1.9.9.826.1.26.16.1.20 | CfprFabricSwSrvPcType | read-only | Cisco Firepower fabric:DceSwSrvPc:type managed object property |
| cfprFabricDceSwSrvPcEpTable | 1.3.6.1.4.1.9.9.826.1.26.17 | not-accessible | Cisco Firepower fabric:DceSwSrvPcEp managed object table | |
| cfprFabricDceSwSrvPcEpEntry | 1.3.6.1.4.1.9.9.826.1.26.17.1 | not-accessible | Entry for the cfprFabricDceSwSrvPcEpTable table. | |
| CFP cfprFabricDceSwSrvPcEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.17.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricDceSwSrvPcEpDnData | 1.3.6.1.4.1.9.9.826.1.26.17.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:DceSwSrvPcEp:dn managed object property |
| STR cfprFabricDceSwSrvPcEpRn | 1.3.6.1.4.1.9.9.826.1.26.17.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvPcEp:rn managed object property |
| NUM cfprFabricDceSwSrvPcEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.17.1.4 | CfprFabricInternalEpAdminState | read-only | Cisco Firepower fabric:DceSwSrvPcEp:adminState managed object property |
| G32 cfprFabricDceSwSrvPcEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.17.1.5 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvPcEp:aggrPortId managed object property |
| G32 cfprFabricDceSwSrvPcEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.17.1.6 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvPcEp:chassisId managed object property |
| STR cfprFabricDceSwSrvPcEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.17.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvPcEp:epDn managed object property |
| UNS cfprFabricDceSwSrvPcEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.17.1.8 | Unsigned64 | read-only | Cisco Firepower fabric:DceSwSrvPcEp:fltAggr managed object property |
| CFP cfprFabricDceSwSrvPcEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.17.1.9 | CfprFabricSwSrvEpIfRole | read-only | Cisco Firepower fabric:DceSwSrvPcEp:ifRole managed object property |
| CFP cfprFabricDceSwSrvPcEpIfType | 1.3.6.1.4.1.9.9.826.1.26.17.1.10 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:DceSwSrvPcEp:ifType managed object property |
| UNS cfprFabricDceSwSrvPcEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.17.1.11 | Unsigned64 | read-only | Cisco Firepower fabric:DceSwSrvPcEp:licGP managed object property |
| CFP cfprFabricDceSwSrvPcEpLicState | 1.3.6.1.4.1.9.9.826.1.26.17.1.12 | CfprLicenseState | read-only | Cisco Firepower fabric:DceSwSrvPcEp:licState managed object property |
| NUM cfprFabricDceSwSrvPcEpLocale | 1.3.6.1.4.1.9.9.826.1.26.17.1.13 | CfprFabricInternalEpLocale | read-only | Cisco Firepower fabric:DceSwSrvPcEp:locale managed object property |
| CFP cfprFabricDceSwSrvPcEpMembership | 1.3.6.1.4.1.9.9.826.1.26.17.1.14 | CfprFabricMembershipStatus | read-only | Cisco Firepower fabric:DceSwSrvPcEp:membership managed object property |
| STR cfprFabricDceSwSrvPcEpName | 1.3.6.1.4.1.9.9.826.1.26.17.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvPcEp:name managed object property |
| CFP cfprFabricDceSwSrvPcEpOperState | 1.3.6.1.4.1.9.9.826.1.26.17.1.16 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:DceSwSrvPcEp:operState managed object property |
| STR cfprFabricDceSwSrvPcEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.17.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvPcEp:operStateReason managed object property |
| G32 cfprFabricDceSwSrvPcEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.17.1.18 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvPcEp:peerAggrPortId managed object property |
| G32 cfprFabricDceSwSrvPcEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.17.1.19 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvPcEp:peerChassisId managed object property |
| STR cfprFabricDceSwSrvPcEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.17.1.20 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvPcEp:peerDn managed object property |
| G32 cfprFabricDceSwSrvPcEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.17.1.21 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvPcEp:peerPortId managed object property |
| G32 cfprFabricDceSwSrvPcEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.17.1.22 | Gauge32 | read-only | Cisco Firepower fabric:DceSwSrvPcEp:peerSlotId managed object property |
| CFP cfprFabricDceSwSrvPcEpPortId | 1.3.6.1.4.1.9.9.826.1.26.17.1.23 | CfprFabricDceSwSrvPcEpPortId | read-only | Cisco Firepower fabric:DceSwSrvPcEp:portId managed object property |
| CFP cfprFabricDceSwSrvPcEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.17.1.24 | CfprFabricDceSwSrvPcEpSlotId | read-only | Cisco Firepower fabric:DceSwSrvPcEp:slotId managed object property |
| CFP cfprFabricDceSwSrvPcEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.17.1.25 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:DceSwSrvPcEp:switchId managed object property |
| CFP cfprFabricDceSwSrvPcEpTransport | 1.3.6.1.4.1.9.9.826.1.26.17.1.26 | CfprFabricADceSwSrvEpTransport | read-only | Cisco Firepower fabric:DceSwSrvPcEp:transport managed object property |
| CFP cfprFabricDceSwSrvPcEpType | 1.3.6.1.4.1.9.9.826.1.26.17.1.27 | CfprFabricSwSrvEpType | read-only | Cisco Firepower fabric:DceSwSrvPcEp:type managed object property |
| STR cfprFabricDceSwSrvPcEpUsrLbl | 1.3.6.1.4.1.9.9.826.1.26.17.1.28 | SnmpAdminString | read-only | Cisco Firepower fabric:DceSwSrvPcEp:usrLbl managed object property |
| cfprFabricEpTable | 1.3.6.1.4.1.9.9.826.1.26.18 | not-accessible | Cisco Firepower fabric:Ep managed object table | |
| cfprFabricEpEntry | 1.3.6.1.4.1.9.9.826.1.26.18.1 | not-accessible | Entry for the cfprFabricEpTable table. | |
| CFP cfprFabricEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.18.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEpDn | 1.3.6.1.4.1.9.9.826.1.26.18.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:Ep:dn managed object property |
| STR cfprFabricEpRn | 1.3.6.1.4.1.9.9.826.1.26.18.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:Ep:rn managed object property |
| cfprFabricEpMgrTable | 1.3.6.1.4.1.9.9.826.1.26.19 | not-accessible | Cisco Firepower fabric:EpMgr managed object table | |
| cfprFabricEpMgrEntry | 1.3.6.1.4.1.9.9.826.1.26.19.1 | not-accessible | Entry for the cfprFabricEpMgrTable table. | |
| CFP cfprFabricEpMgrInstanceId | 1.3.6.1.4.1.9.9.826.1.26.19.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEpMgrDn | 1.3.6.1.4.1.9.9.826.1.26.19.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EpMgr:dn managed object property |
| STR cfprFabricEpMgrRn | 1.3.6.1.4.1.9.9.826.1.26.19.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgr:rn managed object property |
| CFP cfprFabricEpMgrConfMode | 1.3.6.1.4.1.9.9.826.1.26.19.1.4 | CfprFabricConfMode | read-only | Cisco Firepower fabric:EpMgr:confMode managed object property |
| STR cfprFabricEpMgrConfQual | 1.3.6.1.4.1.9.9.826.1.26.19.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgr:confQual managed object property |
| CFP cfprFabricEpMgrConfState | 1.3.6.1.4.1.9.9.826.1.26.19.1.6 | CfprFabricConfState | read-only | Cisco Firepower fabric:EpMgr:confState managed object property |
| UNS cfprFabricEpMgrFltAggr | 1.3.6.1.4.1.9.9.826.1.26.19.1.7 | Unsigned64 | read-only | Cisco Firepower fabric:EpMgr:fltAggr managed object property |
| STR cfprFabricEpMgrFsmDescr | 1.3.6.1.4.1.9.9.826.1.26.19.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgr:fsmDescr managed object property |
| STR cfprFabricEpMgrFsmFlags | 1.3.6.1.4.1.9.9.826.1.26.19.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgr:fsmFlags managed object property |
| STR cfprFabricEpMgrFsmPrev | 1.3.6.1.4.1.9.9.826.1.26.19.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgr:fsmPrev managed object property |
| G32 cfprFabricEpMgrFsmProgr | 1.3.6.1.4.1.9.9.826.1.26.19.1.11 | Gauge32 | read-only | Cisco Firepower fabric:EpMgr:fsmProgr managed object property |
| G32 cfprFabricEpMgrFsmRmtInvErrCode | 1.3.6.1.4.1.9.9.826.1.26.19.1.12 | Gauge32 | read-only | Cisco Firepower fabric:EpMgr:fsmRmtInvErrCode managed object property |
| STR cfprFabricEpMgrFsmRmtInvErrDescr | 1.3.6.1.4.1.9.9.826.1.26.19.1.13 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgr:fsmRmtInvErrDescr managed object property |
| CFP cfprFabricEpMgrFsmRmtInvRslt | 1.3.6.1.4.1.9.9.826.1.26.19.1.14 | CfprConditionRemoteInvRslt | read-only | Cisco Firepower fabric:EpMgr:fsmRmtInvRslt managed object property |
| STR cfprFabricEpMgrFsmStageDescr | 1.3.6.1.4.1.9.9.826.1.26.19.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgr:fsmStageDescr managed object property |
| DAT cfprFabricEpMgrFsmStamp | 1.3.6.1.4.1.9.9.826.1.26.19.1.16 | DateAndTime | read-only | Cisco Firepower fabric:EpMgr:fsmStamp managed object property |
| STR cfprFabricEpMgrFsmStatus | 1.3.6.1.4.1.9.9.826.1.26.19.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgr:fsmStatus managed object property |
| G32 cfprFabricEpMgrFsmTry | 1.3.6.1.4.1.9.9.826.1.26.19.1.18 | Gauge32 | read-only | Cisco Firepower fabric:EpMgr:fsmTry managed object property |
| CFP cfprFabricEpMgrId | 1.3.6.1.4.1.9.9.826.1.26.19.1.19 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EpMgr:id managed object property |
| cfprFabricEpMgrFsmTable | 1.3.6.1.4.1.9.9.826.1.26.20 | not-accessible | Cisco Firepower fabric:EpMgrFsm managed object table | |
| cfprFabricEpMgrFsmEntry | 1.3.6.1.4.1.9.9.826.1.26.20.1 | not-accessible | Entry for the cfprFabricEpMgrFsmTable table. | |
| CFP cfprFabricEpMgrFsmInstanceId | 1.3.6.1.4.1.9.9.826.1.26.20.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEpMgrFsmDn | 1.3.6.1.4.1.9.9.826.1.26.20.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EpMgrFsm:dn managed object property |
| STR cfprFabricEpMgrFsmRn | 1.3.6.1.4.1.9.9.826.1.26.20.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgrFsm:rn managed object property |
| DAT cfprFabricEpMgrFsmCompletionTime | 1.3.6.1.4.1.9.9.826.1.26.20.1.4 | DateAndTime | read-only | Cisco Firepower fabric:EpMgrFsm:completionTime managed object property |
| CFP cfprFabricEpMgrFsmCurrentFsm | 1.3.6.1.4.1.9.9.826.1.26.20.1.5 | CfprFabricEpMgrFsmCurrentFsm | read-only | Cisco Firepower fabric:EpMgrFsm:currentFsm managed object property |
| STR cfprFabricEpMgrFsmDescrData | 1.3.6.1.4.1.9.9.826.1.26.20.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgrFsm:descr managed object property |
| CFP cfprFabricEpMgrFsmFsmStatus | 1.3.6.1.4.1.9.9.826.1.26.20.1.7 | CfprFsmFsmStageStatus | read-only | Cisco Firepower fabric:EpMgrFsm:fsmStatus managed object property |
| G32 cfprFabricEpMgrFsmProgress | 1.3.6.1.4.1.9.9.826.1.26.20.1.8 | Gauge32 | read-only | Cisco Firepower fabric:EpMgrFsm:progress managed object property |
| G32 cfprFabricEpMgrFsmRmtErrCode | 1.3.6.1.4.1.9.9.826.1.26.20.1.9 | Gauge32 | read-only | Cisco Firepower fabric:EpMgrFsm:rmtErrCode managed object property |
| STR cfprFabricEpMgrFsmRmtErrDescr | 1.3.6.1.4.1.9.9.826.1.26.20.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgrFsm:rmtErrDescr managed object property |
| CFP cfprFabricEpMgrFsmRmtRslt | 1.3.6.1.4.1.9.9.826.1.26.20.1.11 | CfprConditionRemoteInvRslt | read-only | Cisco Firepower fabric:EpMgrFsm:rmtRslt managed object property |
| cfprFabricEpMgrFsmStageTable | 1.3.6.1.4.1.9.9.826.1.26.21 | not-accessible | Cisco Firepower fabric:EpMgrFsmStage managed object table | |
| cfprFabricEpMgrFsmStageEntry | 1.3.6.1.4.1.9.9.826.1.26.21.1 | not-accessible | Entry for the cfprFabricEpMgrFsmStageTable table. | |
| CFP cfprFabricEpMgrFsmStageInstanceId | 1.3.6.1.4.1.9.9.826.1.26.21.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEpMgrFsmStageDn | 1.3.6.1.4.1.9.9.826.1.26.21.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EpMgrFsmStage:dn managed object property |
| STR cfprFabricEpMgrFsmStageRn | 1.3.6.1.4.1.9.9.826.1.26.21.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgrFsmStage:rn managed object property |
| STR cfprFabricEpMgrFsmStageDescrData | 1.3.6.1.4.1.9.9.826.1.26.21.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgrFsmStage:descr managed object property |
| DAT cfprFabricEpMgrFsmStageLastUpdateTime | 1.3.6.1.4.1.9.9.826.1.26.21.1.5 | DateAndTime | read-only | Cisco Firepower fabric:EpMgrFsmStage:lastUpdateTime managed object property |
| CFP cfprFabricEpMgrFsmStageName | 1.3.6.1.4.1.9.9.826.1.26.21.1.6 | CfprFabricEpMgrFsmStageName | read-only | Cisco Firepower fabric:EpMgrFsmStage:name managed object property |
| G32 cfprFabricEpMgrFsmStageOrder | 1.3.6.1.4.1.9.9.826.1.26.21.1.7 | Gauge32 | read-only | Cisco Firepower fabric:EpMgrFsmStage:order managed object property |
| G32 cfprFabricEpMgrFsmStageRetry | 1.3.6.1.4.1.9.9.826.1.26.21.1.8 | Gauge32 | read-only | Cisco Firepower fabric:EpMgrFsmStage:retry managed object property |
| CFP cfprFabricEpMgrFsmStageStageStatus | 1.3.6.1.4.1.9.9.826.1.26.21.1.9 | CfprFsmFsmStageStatus | read-only | Cisco Firepower fabric:EpMgrFsmStage:stageStatus managed object property |
| cfprFabricEpMgrFsmTaskTable | 1.3.6.1.4.1.9.9.826.1.26.22 | not-accessible | Cisco Firepower fabric:EpMgrFsmTask managed object table | |
| cfprFabricEpMgrFsmTaskEntry | 1.3.6.1.4.1.9.9.826.1.26.22.1 | not-accessible | Entry for the cfprFabricEpMgrFsmTaskTable table. | |
| CFP cfprFabricEpMgrFsmTaskInstanceId | 1.3.6.1.4.1.9.9.826.1.26.22.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEpMgrFsmTaskDn | 1.3.6.1.4.1.9.9.826.1.26.22.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EpMgrFsmTask:dn managed object property |
| STR cfprFabricEpMgrFsmTaskRn | 1.3.6.1.4.1.9.9.826.1.26.22.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EpMgrFsmTask:rn managed object property |
| CFP cfprFabricEpMgrFsmTaskCompletion | 1.3.6.1.4.1.9.9.826.1.26.22.1.4 | CfprFsmCompletion | read-only | Cisco Firepower fabric:EpMgrFsmTask:completion managed object property |
| CFP cfprFabricEpMgrFsmTaskFlags | 1.3.6.1.4.1.9.9.826.1.26.22.1.5 | CfprFabricEpMgrFsmTaskFlags | read-only | Cisco Firepower fabric:EpMgrFsmTask:flags managed object property |
| CFP cfprFabricEpMgrFsmTaskItem | 1.3.6.1.4.1.9.9.826.1.26.22.1.6 | CfprFabricEpMgrFsmTaskItem | read-only | Cisco Firepower fabric:EpMgrFsmTask:item managed object property |
| G32 cfprFabricEpMgrFsmTaskSeqId | 1.3.6.1.4.1.9.9.826.1.26.22.1.7 | Gauge32 | read-only | Cisco Firepower fabric:EpMgrFsmTask:seqId managed object property |
| cfprFabricEthEstcTable | 1.3.6.1.4.1.9.9.826.1.26.23 | not-accessible | Cisco Firepower fabric:EthEstc managed object table | |
| cfprFabricEthEstcEntry | 1.3.6.1.4.1.9.9.826.1.26.23.1 | not-accessible | Entry for the cfprFabricEthEstcTable table. | |
| CFP cfprFabricEthEstcInstanceId | 1.3.6.1.4.1.9.9.826.1.26.23.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthEstcDn | 1.3.6.1.4.1.9.9.826.1.26.23.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthEstc:dn managed object property |
| STR cfprFabricEthEstcRn | 1.3.6.1.4.1.9.9.826.1.26.23.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstc:rn managed object property |
| CFP cfprFabricEthEstcId | 1.3.6.1.4.1.9.9.826.1.26.23.1.4 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthEstc:id managed object property |
| CFP cfprFabricEthEstcLocale | 1.3.6.1.4.1.9.9.826.1.26.23.1.5 | CfprFabricExternalLocale | read-only | Cisco Firepower fabric:EthEstc:locale managed object property |
| STR cfprFabricEthEstcName | 1.3.6.1.4.1.9.9.826.1.26.23.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstc:name managed object property |
| CFP cfprFabricEthEstcTransport | 1.3.6.1.4.1.9.9.826.1.26.23.1.7 | CfprFabricEthEstcTransport | read-only | Cisco Firepower fabric:EthEstc:transport managed object property |
| CFP cfprFabricEthEstcType | 1.3.6.1.4.1.9.9.826.1.26.23.1.8 | CfprFabricEthEstcType | read-only | Cisco Firepower fabric:EthEstc:type managed object property |
| cfprFabricEthEstcCloudTable | 1.3.6.1.4.1.9.9.826.1.26.24 | not-accessible | Cisco Firepower fabric:EthEstcCloud managed object table | |
| cfprFabricEthEstcCloudEntry | 1.3.6.1.4.1.9.9.826.1.26.24.1 | not-accessible | Entry for the cfprFabricEthEstcCloudTable table. | |
| CFP cfprFabricEthEstcCloudInstanceId | 1.3.6.1.4.1.9.9.826.1.26.24.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthEstcCloudDn | 1.3.6.1.4.1.9.9.826.1.26.24.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthEstcCloud:dn managed object property |
| STR cfprFabricEthEstcCloudRn | 1.3.6.1.4.1.9.9.826.1.26.24.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcCloud:rn managed object property |
| cfprFabricEthEstcEpTable | 1.3.6.1.4.1.9.9.826.1.26.25 | not-accessible | Cisco Firepower fabric:EthEstcEp managed object table | |
| cfprFabricEthEstcEpEntry | 1.3.6.1.4.1.9.9.826.1.26.25.1 | not-accessible | Entry for the cfprFabricEthEstcEpTable table. | |
| CFP cfprFabricEthEstcEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.25.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthEstcEpDn | 1.3.6.1.4.1.9.9.826.1.26.25.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthEstcEp:dn managed object property |
| STR cfprFabricEthEstcEpRn | 1.3.6.1.4.1.9.9.826.1.26.25.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcEp:rn managed object property |
| CFP cfprFabricEthEstcEpAdminSpeed | 1.3.6.1.4.1.9.9.826.1.26.25.1.4 | CfprPortEthSpeed | read-only | Cisco Firepower fabric:EthEstcEp:adminSpeed managed object property |
| CFP cfprFabricEthEstcEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.25.1.5 | CfprFabricExternalEpAdminState | read-only | Cisco Firepower fabric:EthEstcEp:adminState managed object property |
| G32 cfprFabricEthEstcEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.25.1.6 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcEp:aggrPortId managed object property |
| G32 cfprFabricEthEstcEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.25.1.7 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcEp:chassisId managed object property |
| CFP cfprFabricEthEstcEpConfigState | 1.3.6.1.4.1.9.9.826.1.26.25.1.8 | CfprFabricConfigState | read-only | Cisco Firepower fabric:EthEstcEp:configState managed object property |
| STR cfprFabricEthEstcEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.25.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcEp:epDn managed object property |
| STR cfprFabricEthEstcEpFlowCtrlPolicy | 1.3.6.1.4.1.9.9.826.1.26.25.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcEp:flowCtrlPolicy managed object property |
| UNS cfprFabricEthEstcEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.25.1.11 | Unsigned64 | read-only | Cisco Firepower fabric:EthEstcEp:fltAggr managed object property |
| CFP cfprFabricEthEstcEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.25.1.12 | CfprFabricAEthEstcEpIfRole | read-only | Cisco Firepower fabric:EthEstcEp:ifRole managed object property |
| CFP cfprFabricEthEstcEpIfType | 1.3.6.1.4.1.9.9.826.1.26.25.1.13 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:EthEstcEp:ifType managed object property |
| UNS cfprFabricEthEstcEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.25.1.14 | Unsigned64 | read-only | Cisco Firepower fabric:EthEstcEp:licGP managed object property |
| CFP cfprFabricEthEstcEpLicState | 1.3.6.1.4.1.9.9.826.1.26.25.1.15 | CfprLicenseState | read-only | Cisco Firepower fabric:EthEstcEp:licState managed object property |
| CFP cfprFabricEthEstcEpLocale | 1.3.6.1.4.1.9.9.826.1.26.25.1.16 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:EthEstcEp:locale managed object property |
| STR cfprFabricEthEstcEpName | 1.3.6.1.4.1.9.9.826.1.26.25.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcEp:name managed object property |
| STR cfprFabricEthEstcEpNwCtrlPolicyName | 1.3.6.1.4.1.9.9.826.1.26.25.1.18 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcEp:nwCtrlPolicyName managed object property |
| STR cfprFabricEthEstcEpOperNwCtrlPolicyName | 1.3.6.1.4.1.9.9.826.1.26.25.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcEp:operNwCtrlPolicyName managed object property |
| CFP cfprFabricEthEstcEpOperPortMode | 1.3.6.1.4.1.9.9.826.1.26.25.1.20 | CfprFabricEthEstcOperPortMode | read-only | Cisco Firepower fabric:EthEstcEp:operPortMode managed object property |
| CFP cfprFabricEthEstcEpOperState | 1.3.6.1.4.1.9.9.826.1.26.25.1.21 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:EthEstcEp:operState managed object property |
| STR cfprFabricEthEstcEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.25.1.22 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcEp:operStateReason managed object property |
| G32 cfprFabricEthEstcEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.25.1.23 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcEp:peerAggrPortId managed object property |
| G32 cfprFabricEthEstcEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.25.1.24 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcEp:peerChassisId managed object property |
| STR cfprFabricEthEstcEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.25.1.25 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcEp:peerDn managed object property |
| G32 cfprFabricEthEstcEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.25.1.26 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcEp:peerPortId managed object property |
| G32 cfprFabricEthEstcEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.25.1.27 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcEp:peerSlotId managed object property |
| STR cfprFabricEthEstcEpPinGroupName | 1.3.6.1.4.1.9.9.826.1.26.25.1.28 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcEp:pinGroupName managed object property |
| CFP cfprFabricEthEstcEpPortId | 1.3.6.1.4.1.9.9.826.1.26.25.1.29 | CfprFabricEthEstcEpPortId | read-only | Cisco Firepower fabric:EthEstcEp:portId managed object property |
| CFP cfprFabricEthEstcEpPortMode | 1.3.6.1.4.1.9.9.826.1.26.25.1.30 | CfprFabricEthEstcPortMode | read-only | Cisco Firepower fabric:EthEstcEp:portMode managed object property |
| CFP cfprFabricEthEstcEpPrio | 1.3.6.1.4.1.9.9.826.1.26.25.1.31 | CfprFabricEthEstcEpPrio | read-only | Cisco Firepower fabric:EthEstcEp:prio managed object property |
| CFP cfprFabricEthEstcEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.25.1.32 | CfprFabricEthEstcEpSlotId | read-only | Cisco Firepower fabric:EthEstcEp:slotId managed object property |
| CFP cfprFabricEthEstcEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.25.1.33 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthEstcEp:switchId managed object property |
| CFP cfprFabricEthEstcEpTransport | 1.3.6.1.4.1.9.9.826.1.26.25.1.34 | CfprFabricEthEstcEpTransport | read-only | Cisco Firepower fabric:EthEstcEp:transport managed object property |
| CFP cfprFabricEthEstcEpType | 1.3.6.1.4.1.9.9.826.1.26.25.1.35 | CfprFabricEthEstcEpType | read-only | Cisco Firepower fabric:EthEstcEp:type managed object property |
| STR cfprFabricEthEstcEpUsrLbl | 1.3.6.1.4.1.9.9.826.1.26.25.1.36 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcEp:usrLbl managed object property |
| CFP cfprFabricEthEstcEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.25.1.37 | CfprFabricWarnings | read-only | Cisco Firepower fabric:EthEstcEp:warnings managed object property |
| cfprFabricEthEstcPcTable | 1.3.6.1.4.1.9.9.826.1.26.26 | not-accessible | Cisco Firepower fabric:EthEstcPc managed object table | |
| cfprFabricEthEstcPcEntry | 1.3.6.1.4.1.9.9.826.1.26.26.1 | not-accessible | Entry for the cfprFabricEthEstcPcTable table. | |
| CFP cfprFabricEthEstcPcInstanceId | 1.3.6.1.4.1.9.9.826.1.26.26.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthEstcPcDn | 1.3.6.1.4.1.9.9.826.1.26.26.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthEstcPc:dn managed object property |
| STR cfprFabricEthEstcPcRn | 1.3.6.1.4.1.9.9.826.1.26.26.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPc:rn managed object property |
| CFP cfprFabricEthEstcPcAdminSpeed | 1.3.6.1.4.1.9.9.826.1.26.26.1.4 | CfprPortEthAdminSpeed | read-only | Cisco Firepower fabric:EthEstcPc:adminSpeed managed object property |
| CFP cfprFabricEthEstcPcAdminState | 1.3.6.1.4.1.9.9.826.1.26.26.1.5 | CfprFabricCIoEpAdminState | read-only | Cisco Firepower fabric:EthEstcPc:adminState managed object property |
| STR cfprFabricEthEstcPcDescr | 1.3.6.1.4.1.9.9.826.1.26.26.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPc:descr managed object property |
| STR cfprFabricEthEstcPcEpDn | 1.3.6.1.4.1.9.9.826.1.26.26.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPc:epDn managed object property |
| STR cfprFabricEthEstcPcFlowCtrlPolicy | 1.3.6.1.4.1.9.9.826.1.26.26.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPc:flowCtrlPolicy managed object property |
| UNS cfprFabricEthEstcPcFltAggr | 1.3.6.1.4.1.9.9.826.1.26.26.1.9 | Unsigned64 | read-only | Cisco Firepower fabric:EthEstcPc:fltAggr managed object property |
| CFP cfprFabricEthEstcPcIfRole | 1.3.6.1.4.1.9.9.826.1.26.26.1.10 | CfprFabricEstcPcIfRole | read-only | Cisco Firepower fabric:EthEstcPc:ifRole managed object property |
| CFP cfprFabricEthEstcPcIfType | 1.3.6.1.4.1.9.9.826.1.26.26.1.11 | CfprFabricCIoEpIfType | read-only | Cisco Firepower fabric:EthEstcPc:ifType managed object property |
| STR cfprFabricEthEstcPcLacpPolicyName | 1.3.6.1.4.1.9.9.826.1.26.26.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPc:lacpPolicyName managed object property |
| CFP cfprFabricEthEstcPcLocale | 1.3.6.1.4.1.9.9.826.1.26.26.1.13 | CfprFabricExternalPcLocale | read-only | Cisco Firepower fabric:EthEstcPc:locale managed object property |
| STR cfprFabricEthEstcPcName | 1.3.6.1.4.1.9.9.826.1.26.26.1.14 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPc:name managed object property |
| STR cfprFabricEthEstcPcNwCtrlPolicyName | 1.3.6.1.4.1.9.9.826.1.26.26.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPc:nwCtrlPolicyName managed object property |
| STR cfprFabricEthEstcPcOperLacpPolicyName | 1.3.6.1.4.1.9.9.826.1.26.26.1.16 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPc:operLacpPolicyName managed object property |
| STR cfprFabricEthEstcPcOperNwCtrlPolicyName | 1.3.6.1.4.1.9.9.826.1.26.26.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPc:operNwCtrlPolicyName managed object property |
| CFP cfprFabricEthEstcPcOperSpeed | 1.3.6.1.4.1.9.9.826.1.26.26.1.18 | CfprPortEthSpeed | read-only | Cisco Firepower fabric:EthEstcPc:operSpeed managed object property |
| CFP cfprFabricEthEstcPcOperState | 1.3.6.1.4.1.9.9.826.1.26.26.1.19 | CfprNetworkPortOperState | read-only | Cisco Firepower fabric:EthEstcPc:operState managed object property |
| STR cfprFabricEthEstcPcPeerDn | 1.3.6.1.4.1.9.9.826.1.26.26.1.20 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPc:peerDn managed object property |
| STR cfprFabricEthEstcPcPinGroupName | 1.3.6.1.4.1.9.9.826.1.26.26.1.21 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPc:pinGroupName managed object property |
| G32 cfprFabricEthEstcPcPortId | 1.3.6.1.4.1.9.9.826.1.26.26.1.22 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcPc:portId managed object property |
| CFP cfprFabricEthEstcPcPortMode | 1.3.6.1.4.1.9.9.826.1.26.26.1.23 | CfprFabricEthEstcPortMode | read-only | Cisco Firepower fabric:EthEstcPc:portMode managed object property |
| CFP cfprFabricEthEstcPcPrio | 1.3.6.1.4.1.9.9.826.1.26.26.1.24 | CfprQosPriority | read-only | Cisco Firepower fabric:EthEstcPc:prio managed object property |
| CFP cfprFabricEthEstcPcProtocol | 1.3.6.1.4.1.9.9.826.1.26.26.1.25 | CfprFabricEthPcProtocol | read-only | Cisco Firepower fabric:EthEstcPc:protocol managed object property |
| STR cfprFabricEthEstcPcStateQual | 1.3.6.1.4.1.9.9.826.1.26.26.1.26 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPc:stateQual managed object property |
| CFP cfprFabricEthEstcPcSwitchId | 1.3.6.1.4.1.9.9.826.1.26.26.1.27 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthEstcPc:switchId managed object property |
| CFP cfprFabricEthEstcPcTransport | 1.3.6.1.4.1.9.9.826.1.26.26.1.28 | CfprFabricEthEstcPcTransport | read-only | Cisco Firepower fabric:EthEstcPc:transport managed object property |
| CFP cfprFabricEthEstcPcType | 1.3.6.1.4.1.9.9.826.1.26.26.1.29 | CfprFabricEstcPcType | read-only | Cisco Firepower fabric:EthEstcPc:type managed object property |
| CFP cfprFabricEthEstcPcWarnings | 1.3.6.1.4.1.9.9.826.1.26.26.1.30 | CfprFabricWarnings | read-only | Cisco Firepower fabric:EthEstcPc:warnings managed object property |
| cfprFabricEthEstcPcEpTable | 1.3.6.1.4.1.9.9.826.1.26.27 | not-accessible | Cisco Firepower fabric:EthEstcPcEp managed object table | |
| cfprFabricEthEstcPcEpEntry | 1.3.6.1.4.1.9.9.826.1.26.27.1 | not-accessible | Entry for the cfprFabricEthEstcPcEpTable table. | |
| CFP cfprFabricEthEstcPcEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.27.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthEstcPcEpDnData | 1.3.6.1.4.1.9.9.826.1.26.27.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthEstcPcEp:dn managed object property |
| STR cfprFabricEthEstcPcEpRn | 1.3.6.1.4.1.9.9.826.1.26.27.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPcEp:rn managed object property |
| CFP cfprFabricEthEstcPcEpAdminSpeed | 1.3.6.1.4.1.9.9.826.1.26.27.1.4 | CfprPortSpeed | read-only | Cisco Firepower fabric:EthEstcPcEp:adminSpeed managed object property |
| CFP cfprFabricEthEstcPcEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.27.1.5 | CfprFabricExternalEpAdminState | read-only | Cisco Firepower fabric:EthEstcPcEp:adminState managed object property |
| G32 cfprFabricEthEstcPcEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.27.1.6 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcPcEp:aggrPortId managed object property |
| G32 cfprFabricEthEstcPcEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.27.1.7 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcPcEp:chassisId managed object property |
| CFP cfprFabricEthEstcPcEpConfigState | 1.3.6.1.4.1.9.9.826.1.26.27.1.8 | CfprFabricConfigState | read-only | Cisco Firepower fabric:EthEstcPcEp:configState managed object property |
| STR cfprFabricEthEstcPcEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.27.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPcEp:epDn managed object property |
| UNS cfprFabricEthEstcPcEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.27.1.10 | Unsigned64 | read-only | Cisco Firepower fabric:EthEstcPcEp:fltAggr managed object property |
| CFP cfprFabricEthEstcPcEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.27.1.11 | CfprFabricAEthEstcEpIfRole | read-only | Cisco Firepower fabric:EthEstcPcEp:ifRole managed object property |
| CFP cfprFabricEthEstcPcEpIfType | 1.3.6.1.4.1.9.9.826.1.26.27.1.12 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:EthEstcPcEp:ifType managed object property |
| UNS cfprFabricEthEstcPcEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.27.1.13 | Unsigned64 | read-only | Cisco Firepower fabric:EthEstcPcEp:licGP managed object property |
| CFP cfprFabricEthEstcPcEpLicState | 1.3.6.1.4.1.9.9.826.1.26.27.1.14 | CfprLicenseState | read-only | Cisco Firepower fabric:EthEstcPcEp:licState managed object property |
| CFP cfprFabricEthEstcPcEpLocale | 1.3.6.1.4.1.9.9.826.1.26.27.1.15 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:EthEstcPcEp:locale managed object property |
| CFP cfprFabricEthEstcPcEpMembership | 1.3.6.1.4.1.9.9.826.1.26.27.1.16 | CfprFabricMembershipStatus | read-only | Cisco Firepower fabric:EthEstcPcEp:membership managed object property |
| STR cfprFabricEthEstcPcEpName | 1.3.6.1.4.1.9.9.826.1.26.27.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPcEp:name managed object property |
| CFP cfprFabricEthEstcPcEpOperState | 1.3.6.1.4.1.9.9.826.1.26.27.1.18 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:EthEstcPcEp:operState managed object property |
| STR cfprFabricEthEstcPcEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.27.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPcEp:operStateReason managed object property |
| G32 cfprFabricEthEstcPcEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.27.1.20 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcPcEp:peerAggrPortId managed object property |
| G32 cfprFabricEthEstcPcEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.27.1.21 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcPcEp:peerChassisId managed object property |
| STR cfprFabricEthEstcPcEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.27.1.22 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPcEp:peerDn managed object property |
| G32 cfprFabricEthEstcPcEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.27.1.23 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcPcEp:peerPortId managed object property |
| G32 cfprFabricEthEstcPcEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.27.1.24 | Gauge32 | read-only | Cisco Firepower fabric:EthEstcPcEp:peerSlotId managed object property |
| CFP cfprFabricEthEstcPcEpPortId | 1.3.6.1.4.1.9.9.826.1.26.27.1.25 | CfprFabricEthEstcPcEpPortId | read-only | Cisco Firepower fabric:EthEstcPcEp:portId managed object property |
| CFP cfprFabricEthEstcPcEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.27.1.26 | CfprFabricEthEstcPcEpSlotId | read-only | Cisco Firepower fabric:EthEstcPcEp:slotId managed object property |
| CFP cfprFabricEthEstcPcEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.27.1.27 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthEstcPcEp:switchId managed object property |
| CFP cfprFabricEthEstcPcEpTransport | 1.3.6.1.4.1.9.9.826.1.26.27.1.28 | CfprFabricAEthEstcEpTransport | read-only | Cisco Firepower fabric:EthEstcPcEp:transport managed object property |
| CFP cfprFabricEthEstcPcEpType | 1.3.6.1.4.1.9.9.826.1.26.27.1.29 | CfprFabricAEthEstcEpType | read-only | Cisco Firepower fabric:EthEstcPcEp:type managed object property |
| STR cfprFabricEthEstcPcEpUsrLbl | 1.3.6.1.4.1.9.9.826.1.26.27.1.30 | SnmpAdminString | read-only | Cisco Firepower fabric:EthEstcPcEp:usrLbl managed object property |
| CFP cfprFabricEthEstcPcEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.27.1.31 | CfprFabricWarnings | read-only | Cisco Firepower fabric:EthEstcPcEp:warnings managed object property |
| cfprFabricEthLanTable | 1.3.6.1.4.1.9.9.826.1.26.29 | not-accessible | Cisco Firepower fabric:EthLan managed object table | |
| cfprFabricEthLanEntry | 1.3.6.1.4.1.9.9.826.1.26.29.1 | not-accessible | Entry for the cfprFabricEthLanTable table. | |
| CFP cfprFabricEthLanInstanceId | 1.3.6.1.4.1.9.9.826.1.26.29.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthLanDn | 1.3.6.1.4.1.9.9.826.1.26.29.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthLan:dn managed object property |
| STR cfprFabricEthLanRn | 1.3.6.1.4.1.9.9.826.1.26.29.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLan:rn managed object property |
| CFP cfprFabricEthLanId | 1.3.6.1.4.1.9.9.826.1.26.29.1.4 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthLan:id managed object property |
| CFP cfprFabricEthLanLocale | 1.3.6.1.4.1.9.9.826.1.26.29.1.5 | CfprFabricExternalLocale | read-only | Cisco Firepower fabric:EthLan:locale managed object property |
| STR cfprFabricEthLanName | 1.3.6.1.4.1.9.9.826.1.26.29.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLan:name managed object property |
| CFP cfprFabricEthLanTransport | 1.3.6.1.4.1.9.9.826.1.26.29.1.7 | CfprFabricEthLanTransport | read-only | Cisco Firepower fabric:EthLan:transport managed object property |
| CFP cfprFabricEthLanType | 1.3.6.1.4.1.9.9.826.1.26.29.1.8 | CfprFabricLanType | read-only | Cisco Firepower fabric:EthLan:type managed object property |
| cfprFabricEthLanEpTable | 1.3.6.1.4.1.9.9.826.1.26.30 | not-accessible | Cisco Firepower fabric:EthLanEp managed object table | |
| cfprFabricEthLanEpEntry | 1.3.6.1.4.1.9.9.826.1.26.30.1 | not-accessible | Entry for the cfprFabricEthLanEpTable table. | |
| CFP cfprFabricEthLanEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.30.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthLanEpDn | 1.3.6.1.4.1.9.9.826.1.26.30.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthLanEp:dn managed object property |
| STR cfprFabricEthLanEpRn | 1.3.6.1.4.1.9.9.826.1.26.30.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:rn managed object property |
| CFP cfprFabricEthLanEpAdminSpeed | 1.3.6.1.4.1.9.9.826.1.26.30.1.4 | CfprPortEthSpeed | read-only | Cisco Firepower fabric:EthLanEp:adminSpeed managed object property |
| CFP cfprFabricEthLanEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.30.1.5 | CfprFabricEthLanEpAdminState | read-only | Cisco Firepower fabric:EthLanEp:adminState managed object property |
| G32 cfprFabricEthLanEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.30.1.6 | Gauge32 | read-only | Cisco Firepower fabric:EthLanEp:aggrPortId managed object property |
| G32 cfprFabricEthLanEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.30.1.7 | Gauge32 | read-only | Cisco Firepower fabric:EthLanEp:chassisId managed object property |
| G32 cfprFabricEthLanEpDtagVlan | 1.3.6.1.4.1.9.9.826.1.26.30.1.8 | Gauge32 | read-only | Cisco Firepower fabric:EthLanEp:dtagVlan managed object property |
| STR cfprFabricEthLanEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.30.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:epDn managed object property |
| STR cfprFabricEthLanEpEthLinkProfileName | 1.3.6.1.4.1.9.9.826.1.26.30.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:ethLinkProfileName managed object property |
| STR cfprFabricEthLanEpFlowCtrlPolicy | 1.3.6.1.4.1.9.9.826.1.26.30.1.11 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:flowCtrlPolicy managed object property |
| UNS cfprFabricEthLanEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.30.1.12 | Unsigned64 | read-only | Cisco Firepower fabric:EthLanEp:fltAggr managed object property |
| CFP cfprFabricEthLanEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.30.1.13 | CfprFabricLanEpIfRole | read-only | Cisco Firepower fabric:EthLanEp:ifRole managed object property |
| CFP cfprFabricEthLanEpIfType | 1.3.6.1.4.1.9.9.826.1.26.30.1.14 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:EthLanEp:ifType managed object property |
| UNS cfprFabricEthLanEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.30.1.15 | Unsigned64 | read-only | Cisco Firepower fabric:EthLanEp:licGP managed object property |
| CFP cfprFabricEthLanEpLicState | 1.3.6.1.4.1.9.9.826.1.26.30.1.16 | CfprLicenseState | read-only | Cisco Firepower fabric:EthLanEp:licState managed object property |
| CFP cfprFabricEthLanEpLocale | 1.3.6.1.4.1.9.9.826.1.26.30.1.17 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:EthLanEp:locale managed object property |
| STR cfprFabricEthLanEpName | 1.3.6.1.4.1.9.9.826.1.26.30.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:name managed object property |
| STR cfprFabricEthLanEpOperEthLinkProfileName | 1.3.6.1.4.1.9.9.826.1.26.30.1.20 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:operEthLinkProfileName managed object property |
| CFP cfprFabricEthLanEpOperState | 1.3.6.1.4.1.9.9.826.1.26.30.1.21 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:EthLanEp:operState managed object property |
| STR cfprFabricEthLanEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.30.1.22 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:operStateReason managed object property |
| STR cfprFabricEthLanEpOverlappingVlans | 1.3.6.1.4.1.9.9.826.1.26.30.1.23 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:overlappingVlans managed object property |
| G32 cfprFabricEthLanEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.30.1.24 | Gauge32 | read-only | Cisco Firepower fabric:EthLanEp:peerAggrPortId managed object property |
| G32 cfprFabricEthLanEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.30.1.25 | Gauge32 | read-only | Cisco Firepower fabric:EthLanEp:peerChassisId managed object property |
| STR cfprFabricEthLanEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.30.1.26 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:peerDn managed object property |
| G32 cfprFabricEthLanEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.30.1.27 | Gauge32 | read-only | Cisco Firepower fabric:EthLanEp:peerPortId managed object property |
| G32 cfprFabricEthLanEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.30.1.28 | Gauge32 | read-only | Cisco Firepower fabric:EthLanEp:peerSlotId managed object property |
| G32 cfprFabricEthLanEpPortId | 1.3.6.1.4.1.9.9.826.1.26.30.1.29 | Gauge32 | read-only | Cisco Firepower fabric:EthLanEp:portId managed object property |
| G32 cfprFabricEthLanEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.30.1.30 | Gauge32 | read-only | Cisco Firepower fabric:EthLanEp:slotId managed object property |
| CFP cfprFabricEthLanEpSsaPortType | 1.3.6.1.4.1.9.9.826.1.26.30.1.31 | CfprFabricSSAPortType | read-only | Cisco Firepower fabric:EthLanEp:ssaPortType managed object property |
| G32 cfprFabricEthLanEpSsaVlanId | 1.3.6.1.4.1.9.9.826.1.26.30.1.32 | Gauge32 | read-only | Cisco Firepower fabric:EthLanEp:ssaVlanId managed object property |
| CFP cfprFabricEthLanEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.30.1.33 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthLanEp:switchId managed object property |
| CFP cfprFabricEthLanEpTransport | 1.3.6.1.4.1.9.9.826.1.26.30.1.34 | CfprFabricAEthLanEpTransport | read-only | Cisco Firepower fabric:EthLanEp:transport managed object property |
| CFP cfprFabricEthLanEpType | 1.3.6.1.4.1.9.9.826.1.26.30.1.35 | CfprFabricLanEpType | read-only | Cisco Firepower fabric:EthLanEp:type managed object property |
| CFP cfprFabricEthLanEpUdldOperState | 1.3.6.1.4.1.9.9.826.1.26.30.1.36 | CfprFabricUdldOperState | read-only | Cisco Firepower fabric:EthLanEp:udldOperState managed object property |
| STR cfprFabricEthLanEpUsrLbl | 1.3.6.1.4.1.9.9.826.1.26.30.1.37 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:usrLbl managed object property |
| CFP cfprFabricEthLanEpVlanStatus | 1.3.6.1.4.1.9.9.826.1.26.30.1.38 | CfprFabricEthLanEpVlanStatus | read-only | Cisco Firepower fabric:EthLanEp:vlanStatus managed object property |
| CFP cfprFabricEthLanEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.30.1.39 | CfprFabricWarnings | read-only | Cisco Firepower fabric:EthLanEp:warnings managed object property |
| CFP cfprFabricEthLanEpAdminDuplex | 1.3.6.1.4.1.9.9.826.1.26.30.1.40 | CfprPortDuplex | read-only | Cisco Firepower fabric:EthLanEp:adminDuplex managed object property |
| T/F cfprFabricEthLanEpAllowSharing | 1.3.6.1.4.1.9.9.826.1.26.30.1.41 | TruthValue | read-only | Cisco Firepower fabric:EthLanEp:allowSharing managed object property |
| CFP cfprFabricEthLanEpAllowedVlan | 1.3.6.1.4.1.9.9.826.1.26.30.1.42 | CfprFabricAllowedVlanType | read-only | Cisco Firepower fabric:EthLanEp:allowedVlan managed object property |
| T/F cfprFabricEthLanEpAutoNeg | 1.3.6.1.4.1.9.9.826.1.26.30.1.43 | TruthValue | read-only | Cisco Firepower fabric:EthLanEp:autoNeg managed object property |
| STR cfprFabricEthLanEpDescr | 1.3.6.1.4.1.9.9.826.1.26.30.1.44 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:descr managed object property |
| CFP cfprFabricEthLanEpHashAlg | 1.3.6.1.4.1.9.9.826.1.26.30.1.45 | CfprNhTpHashType | read-only | Cisco Firepower fabric:EthLanEp:hashAlg managed object property |
| STR cfprFabricEthLanEpInlinePeerDn | 1.3.6.1.4.1.9.9.826.1.26.30.1.46 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:inlinePeerDn managed object property |
| STR cfprFabricEthLanEpInlinePeerName | 1.3.6.1.4.1.9.9.826.1.26.30.1.47 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:inlinePeerName managed object property |
| CFP cfprFabricEthLanEpInlineState | 1.3.6.1.4.1.9.9.826.1.26.30.1.48 | CfprFabricEthLanEpInlineState | read-only | Cisco Firepower fabric:EthLanEp:inlineState managed object property |
| CFP cfprFabricEthLanEpQosPrio | 1.3.6.1.4.1.9.9.826.1.26.30.1.49 | CfprFabricQosPrio | read-only | Cisco Firepower fabric:EthLanEp:qosPrio managed object property |
| CFP cfprFabricEthLanEpSpeedCap | 1.3.6.1.4.1.9.9.826.1.26.30.1.50 | CfprEquipmentEthPortSpeedCap | read-only | Cisco Firepower fabric:EthLanEp:speedCap managed object property |
| STR cfprFabricEthLanEpNwCtrlPolicyName | 1.3.6.1.4.1.9.9.826.1.26.30.1.51 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:nwCtrlPolicyName managed object property |
| STR cfprFabricEthLanEpOperNwCtrlPolicyName | 1.3.6.1.4.1.9.9.826.1.26.30.1.52 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanEp:operNwCtrlPolicyName managed object property |
| T/F cfprFabricEthLanEpAllowAneg | 1.3.6.1.4.1.9.9.826.1.26.30.1.53 | TruthValue | read-only | Cisco Firepower fabric:EthLanEp:allowAneg managed object property |
| G32 cfprFabricEthLanEpDebounceTime | 1.3.6.1.4.1.9.9.826.1.26.30.1.54 | Gauge32 | read-only | Cisco Firepower fabric:EthLanEp:debounceTime managed object property |
| CFP cfprFabricEthLanEpLastSvcStateDownReason | 1.3.6.1.4.1.9.9.826.1.26.30.1.55 | CfprFabricSvcStateDownReason | read-only | Cisco Firepower fabric:EthLanEp:lastSvcStateDownReason managed object property |
| CFP cfprFabricEthLanEpServiceState | 1.3.6.1.4.1.9.9.826.1.26.30.1.56 | CfprFabricEthLanEpServiceState | read-only | Cisco Firepower fabric:EthLanEp:serviceState managed object property |
| cfprFabricEthLanPcTable | 1.3.6.1.4.1.9.9.826.1.26.32 | not-accessible | Cisco Firepower fabric:EthLanPc managed object table | |
| cfprFabricEthLanPcEntry | 1.3.6.1.4.1.9.9.826.1.26.32.1 | not-accessible | Entry for the cfprFabricEthLanPcTable table. | |
| CFP cfprFabricEthLanPcInstanceId | 1.3.6.1.4.1.9.9.826.1.26.32.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthLanPcDn | 1.3.6.1.4.1.9.9.826.1.26.32.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthLanPc:dn managed object property |
| STR cfprFabricEthLanPcRn | 1.3.6.1.4.1.9.9.826.1.26.32.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:rn managed object property |
| CFP cfprFabricEthLanPcAdminSpeed | 1.3.6.1.4.1.9.9.826.1.26.32.1.4 | CfprPortEthSpeed | read-only | Cisco Firepower fabric:EthLanPc:adminSpeed managed object property |
| CFP cfprFabricEthLanPcAdminState | 1.3.6.1.4.1.9.9.826.1.26.32.1.5 | CfprFabricEthLanPcAdminState | read-only | Cisco Firepower fabric:EthLanPc:adminState managed object property |
| G32 cfprFabricEthLanPcBandwidth | 1.3.6.1.4.1.9.9.826.1.26.32.1.6 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPc:bandwidth managed object property |
| STR cfprFabricEthLanPcClusterName | 1.3.6.1.4.1.9.9.826.1.26.32.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:clusterName managed object property |
| STR cfprFabricEthLanPcDescr | 1.3.6.1.4.1.9.9.826.1.26.32.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:descr managed object property |
| G32 cfprFabricEthLanPcDtagVlan | 1.3.6.1.4.1.9.9.826.1.26.32.1.9 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPc:dtagVlan managed object property |
| STR cfprFabricEthLanPcEpDn | 1.3.6.1.4.1.9.9.826.1.26.32.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:epDn managed object property |
| STR cfprFabricEthLanPcFlowCtrlPolicy | 1.3.6.1.4.1.9.9.826.1.26.32.1.11 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:flowCtrlPolicy managed object property |
| UNS cfprFabricEthLanPcFltAggr | 1.3.6.1.4.1.9.9.826.1.26.32.1.12 | Unsigned64 | read-only | Cisco Firepower fabric:EthLanPc:fltAggr managed object property |
| CFP cfprFabricEthLanPcIfRole | 1.3.6.1.4.1.9.9.826.1.26.32.1.13 | CfprFabricLanPcIfRole | read-only | Cisco Firepower fabric:EthLanPc:ifRole managed object property |
| CFP cfprFabricEthLanPcIfType | 1.3.6.1.4.1.9.9.826.1.26.32.1.14 | CfprFabricCIoEpIfType | read-only | Cisco Firepower fabric:EthLanPc:ifType managed object property |
| STR cfprFabricEthLanPcLacpPolicyName | 1.3.6.1.4.1.9.9.826.1.26.32.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:lacpPolicyName managed object property |
| CFP cfprFabricEthLanPcLocale | 1.3.6.1.4.1.9.9.826.1.26.32.1.16 | CfprFabricExternalPcLocale | read-only | Cisco Firepower fabric:EthLanPc:locale managed object property |
| STR cfprFabricEthLanPcName | 1.3.6.1.4.1.9.9.826.1.26.32.1.18 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:name managed object property |
| STR cfprFabricEthLanPcOperLacpPolicyName | 1.3.6.1.4.1.9.9.826.1.26.32.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:operLacpPolicyName managed object property |
| CFP cfprFabricEthLanPcOperSpeed | 1.3.6.1.4.1.9.9.826.1.26.32.1.20 | CfprPortEthSpeed | read-only | Cisco Firepower fabric:EthLanPc:operSpeed managed object property |
| CFP cfprFabricEthLanPcOperState | 1.3.6.1.4.1.9.9.826.1.26.32.1.21 | CfprNetworkPortOperState | read-only | Cisco Firepower fabric:EthLanPc:operState managed object property |
| STR cfprFabricEthLanPcOverlappingVlans | 1.3.6.1.4.1.9.9.826.1.26.32.1.22 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:overlappingVlans managed object property |
| STR cfprFabricEthLanPcPeerDn | 1.3.6.1.4.1.9.9.826.1.26.32.1.23 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:peerDn managed object property |
| G32 cfprFabricEthLanPcPortId | 1.3.6.1.4.1.9.9.826.1.26.32.1.24 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPc:portId managed object property |
| CFP cfprFabricEthLanPcSpannedCluster | 1.3.6.1.4.1.9.9.826.1.26.32.1.25 | CfprFabricSpannedCluster | read-only | Cisco Firepower fabric:EthLanPc:spannedCluster managed object property |
| CFP cfprFabricEthLanPcSsaPortType | 1.3.6.1.4.1.9.9.826.1.26.32.1.26 | CfprFabricSSAPortType | read-only | Cisco Firepower fabric:EthLanPc:ssaPortType managed object property |
| G32 cfprFabricEthLanPcSsaVlanId | 1.3.6.1.4.1.9.9.826.1.26.32.1.27 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPc:ssaVlanId managed object property |
| STR cfprFabricEthLanPcStateQual | 1.3.6.1.4.1.9.9.826.1.26.32.1.28 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:stateQual managed object property |
| CFP cfprFabricEthLanPcSwitchId | 1.3.6.1.4.1.9.9.826.1.26.32.1.29 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthLanPc:switchId managed object property |
| CFP cfprFabricEthLanPcTransport | 1.3.6.1.4.1.9.9.826.1.26.32.1.30 | CfprFabricEthLanPcTransport | read-only | Cisco Firepower fabric:EthLanPc:transport managed object property |
| CFP cfprFabricEthLanPcType | 1.3.6.1.4.1.9.9.826.1.26.32.1.31 | CfprFabricLanPcType | read-only | Cisco Firepower fabric:EthLanPc:type managed object property |
| CFP cfprFabricEthLanPcVlanStatus | 1.3.6.1.4.1.9.9.826.1.26.32.1.32 | CfprFabricEthLanPcVlanStatus | read-only | Cisco Firepower fabric:EthLanPc:vlanStatus managed object property |
| CFP cfprFabricEthLanPcWarnings | 1.3.6.1.4.1.9.9.826.1.26.32.1.33 | CfprFabricWarnings | read-only | Cisco Firepower fabric:EthLanPc:warnings managed object property |
| G32 cfprFabricEthLanPcCluChassisId | 1.3.6.1.4.1.9.9.826.1.26.32.1.34 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPc:cluChassisId managed object property |
| CFP cfprFabricEthLanPcLacpDetach | 1.3.6.1.4.1.9.9.826.1.26.32.1.35 | CfprFabricEthLanPcLacpDetach | read-only | Cisco Firepower fabric:EthLanPc:lacpDetach managed object property |
| CFP cfprFabricEthLanPcAdminDuplex | 1.3.6.1.4.1.9.9.826.1.26.32.1.36 | CfprPortDuplex | read-only | Cisco Firepower fabric:EthLanPc:adminDuplex managed object property |
| T/F cfprFabricEthLanPcAllowSharing | 1.3.6.1.4.1.9.9.826.1.26.32.1.37 | TruthValue | read-only | Cisco Firepower fabric:EthLanPc:allowSharing managed object property |
| CFP cfprFabricEthLanPcAllowedVlan | 1.3.6.1.4.1.9.9.826.1.26.32.1.38 | CfprFabricAllowedVlanType | read-only | Cisco Firepower fabric:EthLanPc:allowedVlan managed object property |
| T/F cfprFabricEthLanPcAutoNeg | 1.3.6.1.4.1.9.9.826.1.26.32.1.39 | TruthValue | read-only | Cisco Firepower fabric:EthLanPc:autoNeg managed object property |
| CFP cfprFabricEthLanPcHashAlg | 1.3.6.1.4.1.9.9.826.1.26.32.1.40 | CfprNhTpHashType | read-only | Cisco Firepower fabric:EthLanPc:hashAlg managed object property |
| STR cfprFabricEthLanPcInlinePeerDn | 1.3.6.1.4.1.9.9.826.1.26.32.1.41 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:inlinePeerDn managed object property |
| STR cfprFabricEthLanPcInlinePeerName | 1.3.6.1.4.1.9.9.826.1.26.32.1.42 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:inlinePeerName managed object property |
| CFP cfprFabricEthLanPcInlineState | 1.3.6.1.4.1.9.9.826.1.26.32.1.43 | CfprFabricEthLanPcInlineState | read-only | Cisco Firepower fabric:EthLanPc:inlineState managed object property |
| CFP cfprFabricEthLanPcLacpMode | 1.3.6.1.4.1.9.9.826.1.26.32.1.44 | CfprFabricLacpMode | read-only | Cisco Firepower fabric:EthLanPc:lacpMode managed object property |
| CFP cfprFabricEthLanPcPcMode | 1.3.6.1.4.1.9.9.826.1.26.32.1.45 | CfprFabricPcMode | read-only | Cisco Firepower fabric:EthLanPc:pcMode managed object property |
| CFP cfprFabricEthLanPcPcModeState | 1.3.6.1.4.1.9.9.826.1.26.32.1.46 | CfprFabricPcModeState | read-only | Cisco Firepower fabric:EthLanPc:pcModeState managed object property |
| CFP cfprFabricEthLanPcQosPrio | 1.3.6.1.4.1.9.9.826.1.26.32.1.47 | CfprFabricQosPrio | read-only | Cisco Firepower fabric:EthLanPc:qosPrio managed object property |
| CFP cfprFabricEthLanPcSpeedCap | 1.3.6.1.4.1.9.9.826.1.26.32.1.48 | CfprEquipmentEthPortSpeedCap | read-only | Cisco Firepower fabric:EthLanPc:speedCap managed object property |
| STR cfprFabricEthLanPcNwCtrlPolicyName | 1.3.6.1.4.1.9.9.826.1.26.32.1.49 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:nwCtrlPolicyName managed object property |
| STR cfprFabricEthLanPcOperNwCtrlPolicyName | 1.3.6.1.4.1.9.9.826.1.26.32.1.50 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPc:operNwCtrlPolicyName managed object property |
| CFP cfprFabricEthLanPcLastSvcStateDownReason | 1.3.6.1.4.1.9.9.826.1.26.32.1.51 | CfprFabricSvcStateDownReason | read-only | Cisco Firepower fabric:EthLanPc:lastSvcStateDownReason managed object property |
| CFP cfprFabricEthLanPcServiceState | 1.3.6.1.4.1.9.9.826.1.26.32.1.52 | CfprFabricEthLanPcServiceState | read-only | Cisco Firepower fabric:EthLanPc:serviceState managed object property |
| cfprFabricEthLanPcEpTable | 1.3.6.1.4.1.9.9.826.1.26.33 | not-accessible | Cisco Firepower fabric:EthLanPcEp managed object table | |
| cfprFabricEthLanPcEpEntry | 1.3.6.1.4.1.9.9.826.1.26.33.1 | not-accessible | Entry for the cfprFabricEthLanPcEpTable table. | |
| CFP cfprFabricEthLanPcEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.33.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthLanPcEpDnData | 1.3.6.1.4.1.9.9.826.1.26.33.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthLanPcEp:dn managed object property |
| STR cfprFabricEthLanPcEpRn | 1.3.6.1.4.1.9.9.826.1.26.33.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPcEp:rn managed object property |
| CFP cfprFabricEthLanPcEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.33.1.4 | CfprFabricExternalEpAdminState | read-only | Cisco Firepower fabric:EthLanPcEp:adminState managed object property |
| G32 cfprFabricEthLanPcEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.33.1.5 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPcEp:aggrPortId managed object property |
| G32 cfprFabricEthLanPcEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.33.1.6 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPcEp:chassisId managed object property |
| STR cfprFabricEthLanPcEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.33.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPcEp:epDn managed object property |
| STR cfprFabricEthLanPcEpEthLinkProfileName | 1.3.6.1.4.1.9.9.826.1.26.33.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPcEp:ethLinkProfileName managed object property |
| UNS cfprFabricEthLanPcEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.33.1.9 | Unsigned64 | read-only | Cisco Firepower fabric:EthLanPcEp:fltAggr managed object property |
| CFP cfprFabricEthLanPcEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.33.1.10 | CfprFabricLanEpIfRole | read-only | Cisco Firepower fabric:EthLanPcEp:ifRole managed object property |
| CFP cfprFabricEthLanPcEpIfType | 1.3.6.1.4.1.9.9.826.1.26.33.1.11 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:EthLanPcEp:ifType managed object property |
| UNS cfprFabricEthLanPcEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.33.1.12 | Unsigned64 | read-only | Cisco Firepower fabric:EthLanPcEp:licGP managed object property |
| CFP cfprFabricEthLanPcEpLicState | 1.3.6.1.4.1.9.9.826.1.26.33.1.13 | CfprLicenseState | read-only | Cisco Firepower fabric:EthLanPcEp:licState managed object property |
| CFP cfprFabricEthLanPcEpLocale | 1.3.6.1.4.1.9.9.826.1.26.33.1.14 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:EthLanPcEp:locale managed object property |
| CFP cfprFabricEthLanPcEpMembership | 1.3.6.1.4.1.9.9.826.1.26.33.1.15 | CfprFabricMembershipStatus | read-only | Cisco Firepower fabric:EthLanPcEp:membership managed object property |
| STR cfprFabricEthLanPcEpName | 1.3.6.1.4.1.9.9.826.1.26.33.1.16 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPcEp:name managed object property |
| STR cfprFabricEthLanPcEpOperEthLinkProfileName | 1.3.6.1.4.1.9.9.826.1.26.33.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPcEp:operEthLinkProfileName managed object property |
| CFP cfprFabricEthLanPcEpOperState | 1.3.6.1.4.1.9.9.826.1.26.33.1.18 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:EthLanPcEp:operState managed object property |
| STR cfprFabricEthLanPcEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.33.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPcEp:operStateReason managed object property |
| G32 cfprFabricEthLanPcEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.33.1.20 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPcEp:peerAggrPortId managed object property |
| G32 cfprFabricEthLanPcEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.33.1.21 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPcEp:peerChassisId managed object property |
| STR cfprFabricEthLanPcEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.33.1.22 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPcEp:peerDn managed object property |
| G32 cfprFabricEthLanPcEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.33.1.23 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPcEp:peerPortId managed object property |
| G32 cfprFabricEthLanPcEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.33.1.24 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPcEp:peerSlotId managed object property |
| G32 cfprFabricEthLanPcEpPortId | 1.3.6.1.4.1.9.9.826.1.26.33.1.25 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPcEp:portId managed object property |
| G32 cfprFabricEthLanPcEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.33.1.26 | Gauge32 | read-only | Cisco Firepower fabric:EthLanPcEp:slotId managed object property |
| CFP cfprFabricEthLanPcEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.33.1.27 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthLanPcEp:switchId managed object property |
| CFP cfprFabricEthLanPcEpTransport | 1.3.6.1.4.1.9.9.826.1.26.33.1.28 | CfprFabricAEthLanEpTransport | read-only | Cisco Firepower fabric:EthLanPcEp:transport managed object property |
| CFP cfprFabricEthLanPcEpType | 1.3.6.1.4.1.9.9.826.1.26.33.1.29 | CfprFabricLanEpType | read-only | Cisco Firepower fabric:EthLanPcEp:type managed object property |
| CFP cfprFabricEthLanPcEpUdldOperState | 1.3.6.1.4.1.9.9.826.1.26.33.1.30 | CfprFabricUdldOperState | read-only | Cisco Firepower fabric:EthLanPcEp:udldOperState managed object property |
| CFP cfprFabricEthLanPcEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.33.1.31 | CfprFabricWarnings | read-only | Cisco Firepower fabric:EthLanPcEp:warnings managed object property |
| STR cfprFabricEthLanPcEpDescr | 1.3.6.1.4.1.9.9.826.1.26.33.1.32 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLanPcEp:descr managed object property |
| CFP cfprFabricEthLanPcEpSpeedCap | 1.3.6.1.4.1.9.9.826.1.26.33.1.33 | CfprEquipmentEthPortSpeedCap | read-only | Cisco Firepower fabric:EthLanPcEp:speedCap managed object property |
| cfprFabricEthLinkProfileTable | 1.3.6.1.4.1.9.9.826.1.26.34 | not-accessible | Cisco Firepower fabric:EthLinkProfile managed object table | |
| cfprFabricEthLinkProfileEntry | 1.3.6.1.4.1.9.9.826.1.26.34.1 | not-accessible | Entry for the cfprFabricEthLinkProfileTable table. | |
| CFP cfprFabricEthLinkProfileInstanceId | 1.3.6.1.4.1.9.9.826.1.26.34.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthLinkProfileDn | 1.3.6.1.4.1.9.9.826.1.26.34.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthLinkProfile:dn managed object property |
| STR cfprFabricEthLinkProfileRn | 1.3.6.1.4.1.9.9.826.1.26.34.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLinkProfile:rn managed object property |
| STR cfprFabricEthLinkProfileCdpLinkPolicyName | 1.3.6.1.4.1.9.9.826.1.26.34.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLinkProfile:cdpLinkPolicyName managed object property |
| STR cfprFabricEthLinkProfileDescr | 1.3.6.1.4.1.9.9.826.1.26.34.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLinkProfile:descr managed object property |
| STR cfprFabricEthLinkProfileIntId | 1.3.6.1.4.1.9.9.826.1.26.34.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLinkProfile:intId managed object property |
| STR cfprFabricEthLinkProfileName | 1.3.6.1.4.1.9.9.826.1.26.34.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLinkProfile:name managed object property |
| STR cfprFabricEthLinkProfileOperCdpLinkPolicyName | 1.3.6.1.4.1.9.9.826.1.26.34.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLinkProfile:operCdpLinkPolicyName managed object property |
| STR cfprFabricEthLinkProfileOperUdldLinkPolicyName | 1.3.6.1.4.1.9.9.826.1.26.34.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLinkProfile:operUdldLinkPolicyName managed object property |
| G32 cfprFabricEthLinkProfilePolicyLevel | 1.3.6.1.4.1.9.9.826.1.26.34.1.10 | Gauge32 | read-only | Cisco Firepower fabric:EthLinkProfile:policyLevel managed object property |
| CFP cfprFabricEthLinkProfilePolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.34.1.11 | CfprPolicyPolicyOwner | read-only | Cisco Firepower fabric:EthLinkProfile:policyOwner managed object property |
| STR cfprFabricEthLinkProfileUdldLinkPolicyName | 1.3.6.1.4.1.9.9.826.1.26.34.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:EthLinkProfile:udldLinkPolicyName managed object property |
| cfprFabricEthMonTable | 1.3.6.1.4.1.9.9.826.1.26.35 | not-accessible | Cisco Firepower fabric:EthMon managed object table | |
| cfprFabricEthMonEntry | 1.3.6.1.4.1.9.9.826.1.26.35.1 | not-accessible | Entry for the cfprFabricEthMonTable table. | |
| CFP cfprFabricEthMonInstanceId | 1.3.6.1.4.1.9.9.826.1.26.35.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthMonDn | 1.3.6.1.4.1.9.9.826.1.26.35.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthMon:dn managed object property |
| STR cfprFabricEthMonRn | 1.3.6.1.4.1.9.9.826.1.26.35.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMon:rn managed object property |
| CFP cfprFabricEthMonAdminState | 1.3.6.1.4.1.9.9.826.1.26.35.1.4 | CfprFabricMonAdminState | read-only | Cisco Firepower fabric:EthMon:adminState managed object property |
| STR cfprFabricEthMonConfigFailReason | 1.3.6.1.4.1.9.9.826.1.26.35.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMon:configFailReason managed object property |
| CFP cfprFabricEthMonId | 1.3.6.1.4.1.9.9.826.1.26.35.1.6 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthMon:id managed object property |
| T/F cfprFabricEthMonIsConfigSuccess | 1.3.6.1.4.1.9.9.826.1.26.35.1.7 | TruthValue | read-only | Cisco Firepower fabric:EthMon:isConfigSuccess managed object property |
| CFP cfprFabricEthMonLocale | 1.3.6.1.4.1.9.9.826.1.26.35.1.8 | CfprFabricExternalLocale | read-only | Cisco Firepower fabric:EthMon:locale managed object property |
| STR cfprFabricEthMonName | 1.3.6.1.4.1.9.9.826.1.26.35.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMon:name managed object property |
| CFP cfprFabricEthMonOperState | 1.3.6.1.4.1.9.9.826.1.26.35.1.10 | CfprFabricMonOperState | read-only | Cisco Firepower fabric:EthMon:operState managed object property |
| CFP cfprFabricEthMonOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.35.1.11 | CfprFabricMonOperStateReason | read-only | Cisco Firepower fabric:EthMon:operStateReason managed object property |
| STR cfprFabricEthMonPeerDn | 1.3.6.1.4.1.9.9.826.1.26.35.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMon:peerDn managed object property |
| G32 cfprFabricEthMonSession | 1.3.6.1.4.1.9.9.826.1.26.35.1.13 | Gauge32 | read-only | Cisco Firepower fabric:EthMon:session managed object property |
| CFP cfprFabricEthMonTransport | 1.3.6.1.4.1.9.9.826.1.26.35.1.14 | CfprFabricEthMonTransport | read-only | Cisco Firepower fabric:EthMon:transport managed object property |
| CFP cfprFabricEthMonType | 1.3.6.1.4.1.9.9.826.1.26.35.1.15 | CfprFabricEthMonType | read-only | Cisco Firepower fabric:EthMon:type managed object property |
| cfprFabricEthMonDestEpTable | 1.3.6.1.4.1.9.9.826.1.26.36 | not-accessible | Cisco Firepower fabric:EthMonDestEp managed object table | |
| cfprFabricEthMonDestEpEntry | 1.3.6.1.4.1.9.9.826.1.26.36.1 | not-accessible | Entry for the cfprFabricEthMonDestEpTable table. | |
| CFP cfprFabricEthMonDestEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.36.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthMonDestEpDn | 1.3.6.1.4.1.9.9.826.1.26.36.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthMonDestEp:dn managed object property |
| STR cfprFabricEthMonDestEpRn | 1.3.6.1.4.1.9.9.826.1.26.36.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonDestEp:rn managed object property |
| CFP cfprFabricEthMonDestEpAdminSpeed | 1.3.6.1.4.1.9.9.826.1.26.36.1.4 | CfprFabricEthMonDestEpAdminSpeed | read-only | Cisco Firepower fabric:EthMonDestEp:adminSpeed managed object property |
| CFP cfprFabricEthMonDestEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.36.1.5 | CfprFabricExternalEpAdminState | read-only | Cisco Firepower fabric:EthMonDestEp:adminState managed object property |
| G32 cfprFabricEthMonDestEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.36.1.6 | Gauge32 | read-only | Cisco Firepower fabric:EthMonDestEp:aggrPortId managed object property |
| G32 cfprFabricEthMonDestEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.36.1.7 | Gauge32 | read-only | Cisco Firepower fabric:EthMonDestEp:chassisId managed object property |
| STR cfprFabricEthMonDestEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.36.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonDestEp:epDn managed object property |
| UNS cfprFabricEthMonDestEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.36.1.9 | Unsigned64 | read-only | Cisco Firepower fabric:EthMonDestEp:fltAggr managed object property |
| CFP cfprFabricEthMonDestEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.36.1.10 | CfprFabricEthMonDestEpIfRole | read-only | Cisco Firepower fabric:EthMonDestEp:ifRole managed object property |
| CFP cfprFabricEthMonDestEpIfType | 1.3.6.1.4.1.9.9.826.1.26.36.1.11 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:EthMonDestEp:ifType managed object property |
| UNS cfprFabricEthMonDestEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.36.1.12 | Unsigned64 | read-only | Cisco Firepower fabric:EthMonDestEp:licGP managed object property |
| CFP cfprFabricEthMonDestEpLicState | 1.3.6.1.4.1.9.9.826.1.26.36.1.13 | CfprLicenseState | read-only | Cisco Firepower fabric:EthMonDestEp:licState managed object property |
| CFP cfprFabricEthMonDestEpLocale | 1.3.6.1.4.1.9.9.826.1.26.36.1.14 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:EthMonDestEp:locale managed object property |
| STR cfprFabricEthMonDestEpName | 1.3.6.1.4.1.9.9.826.1.26.36.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonDestEp:name managed object property |
| CFP cfprFabricEthMonDestEpOperState | 1.3.6.1.4.1.9.9.826.1.26.36.1.16 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:EthMonDestEp:operState managed object property |
| STR cfprFabricEthMonDestEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.36.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonDestEp:operStateReason managed object property |
| G32 cfprFabricEthMonDestEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.36.1.18 | Gauge32 | read-only | Cisco Firepower fabric:EthMonDestEp:peerAggrPortId managed object property |
| G32 cfprFabricEthMonDestEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.36.1.19 | Gauge32 | read-only | Cisco Firepower fabric:EthMonDestEp:peerChassisId managed object property |
| STR cfprFabricEthMonDestEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.36.1.20 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonDestEp:peerDn managed object property |
| G32 cfprFabricEthMonDestEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.36.1.21 | Gauge32 | read-only | Cisco Firepower fabric:EthMonDestEp:peerPortId managed object property |
| G32 cfprFabricEthMonDestEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.36.1.22 | Gauge32 | read-only | Cisco Firepower fabric:EthMonDestEp:peerSlotId managed object property |
| CFP cfprFabricEthMonDestEpPortId | 1.3.6.1.4.1.9.9.826.1.26.36.1.23 | CfprFabricEthMonDestEpPortId | read-only | Cisco Firepower fabric:EthMonDestEp:portId managed object property |
| CFP cfprFabricEthMonDestEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.36.1.24 | CfprFabricEthMonDestEpSlotId | read-only | Cisco Firepower fabric:EthMonDestEp:slotId managed object property |
| CFP cfprFabricEthMonDestEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.36.1.25 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthMonDestEp:switchId managed object property |
| CFP cfprFabricEthMonDestEpTransport | 1.3.6.1.4.1.9.9.826.1.26.36.1.26 | CfprNetworkTransport | read-only | Cisco Firepower fabric:EthMonDestEp:transport managed object property |
| CFP cfprFabricEthMonDestEpType | 1.3.6.1.4.1.9.9.826.1.26.36.1.27 | CfprFabricEthMonDestEpType | read-only | Cisco Firepower fabric:EthMonDestEp:type managed object property |
| CFP cfprFabricEthMonDestEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.36.1.28 | CfprFabricWarnings | read-only | Cisco Firepower fabric:EthMonDestEp:warnings managed object property |
| cfprFabricEthMonFiltEpTable | 1.3.6.1.4.1.9.9.826.1.26.37 | not-accessible | Cisco Firepower fabric:EthMonFiltEp managed object table | |
| cfprFabricEthMonFiltEpEntry | 1.3.6.1.4.1.9.9.826.1.26.37.1 | not-accessible | Entry for the cfprFabricEthMonFiltEpTable table. | |
| CFP cfprFabricEthMonFiltEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.37.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthMonFiltEpDn | 1.3.6.1.4.1.9.9.826.1.26.37.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthMonFiltEp:dn managed object property |
| STR cfprFabricEthMonFiltEpRn | 1.3.6.1.4.1.9.9.826.1.26.37.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonFiltEp:rn managed object property |
| STR cfprFabricEthMonFiltEpName | 1.3.6.1.4.1.9.9.826.1.26.37.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonFiltEp:name managed object property |
| G32 cfprFabricEthMonFiltEpSession | 1.3.6.1.4.1.9.9.826.1.26.37.1.5 | Gauge32 | read-only | Cisco Firepower fabric:EthMonFiltEp:session managed object property |
| CFP cfprFabricEthMonFiltEpType | 1.3.6.1.4.1.9.9.826.1.26.37.1.6 | CfprFabricEthMonFiltEpType | read-only | Cisco Firepower fabric:EthMonFiltEp:type managed object property |
| cfprFabricEthMonFiltRefTable | 1.3.6.1.4.1.9.9.826.1.26.38 | not-accessible | Cisco Firepower fabric:EthMonFiltRef managed object table | |
| cfprFabricEthMonFiltRefEntry | 1.3.6.1.4.1.9.9.826.1.26.38.1 | not-accessible | Entry for the cfprFabricEthMonFiltRefTable table. | |
| CFP cfprFabricEthMonFiltRefInstanceId | 1.3.6.1.4.1.9.9.826.1.26.38.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthMonFiltRefDn | 1.3.6.1.4.1.9.9.826.1.26.38.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthMonFiltRef:dn managed object property |
| STR cfprFabricEthMonFiltRefRn | 1.3.6.1.4.1.9.9.826.1.26.38.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonFiltRef:rn managed object property |
| STR cfprFabricEthMonFiltRefSrcFiltDn | 1.3.6.1.4.1.9.9.826.1.26.38.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonFiltRef:srcFiltDn managed object property |
| CFP cfprFabricEthMonFiltRefType | 1.3.6.1.4.1.9.9.826.1.26.38.1.5 | CfprFabricEthMonFiltRefType | read-only | Cisco Firepower fabric:EthMonFiltRef:type managed object property |
| cfprFabricEthMonLanTable | 1.3.6.1.4.1.9.9.826.1.26.39 | not-accessible | Cisco Firepower fabric:EthMonLan managed object table | |
| cfprFabricEthMonLanEntry | 1.3.6.1.4.1.9.9.826.1.26.39.1 | not-accessible | Entry for the cfprFabricEthMonLanTable table. | |
| CFP cfprFabricEthMonLanInstanceId | 1.3.6.1.4.1.9.9.826.1.26.39.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthMonLanDn | 1.3.6.1.4.1.9.9.826.1.26.39.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthMonLan:dn managed object property |
| STR cfprFabricEthMonLanRn | 1.3.6.1.4.1.9.9.826.1.26.39.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonLan:rn managed object property |
| CFP cfprFabricEthMonLanId | 1.3.6.1.4.1.9.9.826.1.26.39.1.4 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthMonLan:id managed object property |
| CFP cfprFabricEthMonLanLocale | 1.3.6.1.4.1.9.9.826.1.26.39.1.5 | CfprFabricExternalLocale | read-only | Cisco Firepower fabric:EthMonLan:locale managed object property |
| STR cfprFabricEthMonLanName | 1.3.6.1.4.1.9.9.826.1.26.39.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonLan:name managed object property |
| CFP cfprFabricEthMonLanTransport | 1.3.6.1.4.1.9.9.826.1.26.39.1.7 | CfprFabricEthMonLanTransport | read-only | Cisco Firepower fabric:EthMonLan:transport managed object property |
| CFP cfprFabricEthMonLanType | 1.3.6.1.4.1.9.9.826.1.26.39.1.8 | CfprFabricEthMonLanType | read-only | Cisco Firepower fabric:EthMonLan:type managed object property |
| cfprFabricEthMonSrcEpTable | 1.3.6.1.4.1.9.9.826.1.26.40 | not-accessible | Cisco Firepower fabric:EthMonSrcEp managed object table | |
| cfprFabricEthMonSrcEpEntry | 1.3.6.1.4.1.9.9.826.1.26.40.1 | not-accessible | Entry for the cfprFabricEthMonSrcEpTable table. | |
| CFP cfprFabricEthMonSrcEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.40.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthMonSrcEpDn | 1.3.6.1.4.1.9.9.826.1.26.40.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthMonSrcEp:dn managed object property |
| STR cfprFabricEthMonSrcEpRn | 1.3.6.1.4.1.9.9.826.1.26.40.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonSrcEp:rn managed object property |
| CFP cfprFabricEthMonSrcEpDirection | 1.3.6.1.4.1.9.9.826.1.26.40.1.4 | CfprFabricTrafficDirection | read-only | Cisco Firepower fabric:EthMonSrcEp:direction managed object property |
| STR cfprFabricEthMonSrcEpName | 1.3.6.1.4.1.9.9.826.1.26.40.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonSrcEp:name managed object property |
| G32 cfprFabricEthMonSrcEpSession | 1.3.6.1.4.1.9.9.826.1.26.40.1.6 | Gauge32 | read-only | Cisco Firepower fabric:EthMonSrcEp:session managed object property |
| CFP cfprFabricEthMonSrcEpTransport | 1.3.6.1.4.1.9.9.826.1.26.40.1.7 | CfprNetworkTransport | read-only | Cisco Firepower fabric:EthMonSrcEp:transport managed object property |
| CFP cfprFabricEthMonSrcEpType | 1.3.6.1.4.1.9.9.826.1.26.40.1.8 | CfprFabricEthMonSrcEpType | read-only | Cisco Firepower fabric:EthMonSrcEp:type managed object property |
| cfprFabricEthMonSrcRefTable | 1.3.6.1.4.1.9.9.826.1.26.41 | not-accessible | Cisco Firepower fabric:EthMonSrcRef managed object table | |
| cfprFabricEthMonSrcRefEntry | 1.3.6.1.4.1.9.9.826.1.26.41.1 | not-accessible | Entry for the cfprFabricEthMonSrcRefTable table. | |
| CFP cfprFabricEthMonSrcRefInstanceId | 1.3.6.1.4.1.9.9.826.1.26.41.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthMonSrcRefDn | 1.3.6.1.4.1.9.9.826.1.26.41.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthMonSrcRef:dn managed object property |
| STR cfprFabricEthMonSrcRefRn | 1.3.6.1.4.1.9.9.826.1.26.41.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonSrcRef:rn managed object property |
| UNS cfprFabricEthMonSrcRefId | 1.3.6.1.4.1.9.9.826.1.26.41.1.4 | Unsigned64 | read-only | Cisco Firepower fabric:EthMonSrcRef:id managed object property |
| STR cfprFabricEthMonSrcRefSourceDn | 1.3.6.1.4.1.9.9.826.1.26.41.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:EthMonSrcRef:sourceDn managed object property |
| CFP cfprFabricEthMonSrcRefSourceType | 1.3.6.1.4.1.9.9.826.1.26.41.1.6 | CfprFabricEthSourceType | read-only | Cisco Firepower fabric:EthMonSrcRef:sourceType managed object property |
| CFP cfprFabricEthMonSrcRefType | 1.3.6.1.4.1.9.9.826.1.26.41.1.7 | CfprFabricEthMonSrcRefType | read-only | Cisco Firepower fabric:EthMonSrcRef:type managed object property |
| cfprFabricEthTargetEpTable | 1.3.6.1.4.1.9.9.826.1.26.42 | not-accessible | Cisco Firepower fabric:EthTargetEp managed object table | |
| cfprFabricEthTargetEpEntry | 1.3.6.1.4.1.9.9.826.1.26.42.1 | not-accessible | Entry for the cfprFabricEthTargetEpTable table. | |
| CFP cfprFabricEthTargetEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.42.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthTargetEpDn | 1.3.6.1.4.1.9.9.826.1.26.42.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthTargetEp:dn managed object property |
| STR cfprFabricEthTargetEpRn | 1.3.6.1.4.1.9.9.826.1.26.42.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthTargetEp:rn managed object property |
| CFP cfprFabricEthTargetEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.42.1.4 | CfprFabricExternalEpAdminState | read-only | Cisco Firepower fabric:EthTargetEp:adminState managed object property |
| G32 cfprFabricEthTargetEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.42.1.5 | Gauge32 | read-only | Cisco Firepower fabric:EthTargetEp:aggrPortId managed object property |
| G32 cfprFabricEthTargetEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.42.1.6 | Gauge32 | read-only | Cisco Firepower fabric:EthTargetEp:chassisId managed object property |
| STR cfprFabricEthTargetEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.42.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:EthTargetEp:epDn managed object property |
| UNS cfprFabricEthTargetEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.42.1.8 | Unsigned64 | read-only | Cisco Firepower fabric:EthTargetEp:fltAggr managed object property |
| CFP cfprFabricEthTargetEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.42.1.9 | CfprNetworkPortRole | read-only | Cisco Firepower fabric:EthTargetEp:ifRole managed object property |
| CFP cfprFabricEthTargetEpIfType | 1.3.6.1.4.1.9.9.826.1.26.42.1.10 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:EthTargetEp:ifType managed object property |
| UNS cfprFabricEthTargetEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.42.1.11 | Unsigned64 | read-only | Cisco Firepower fabric:EthTargetEp:licGP managed object property |
| CFP cfprFabricEthTargetEpLicState | 1.3.6.1.4.1.9.9.826.1.26.42.1.12 | CfprLicenseState | read-only | Cisco Firepower fabric:EthTargetEp:licState managed object property |
| CFP cfprFabricEthTargetEpLocale | 1.3.6.1.4.1.9.9.826.1.26.42.1.13 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:EthTargetEp:locale managed object property |
| MAC cfprFabricEthTargetEpMacAddress | 1.3.6.1.4.1.9.9.826.1.26.42.1.14 | MacAddress | read-only | Cisco Firepower fabric:EthTargetEp:macAddress managed object property |
| STR cfprFabricEthTargetEpName | 1.3.6.1.4.1.9.9.826.1.26.42.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:EthTargetEp:name managed object property |
| CFP cfprFabricEthTargetEpOperState | 1.3.6.1.4.1.9.9.826.1.26.42.1.16 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:EthTargetEp:operState managed object property |
| STR cfprFabricEthTargetEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.42.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:EthTargetEp:operStateReason managed object property |
| G32 cfprFabricEthTargetEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.42.1.18 | Gauge32 | read-only | Cisco Firepower fabric:EthTargetEp:peerAggrPortId managed object property |
| G32 cfprFabricEthTargetEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.42.1.19 | Gauge32 | read-only | Cisco Firepower fabric:EthTargetEp:peerChassisId managed object property |
| STR cfprFabricEthTargetEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.42.1.20 | SnmpAdminString | read-only | Cisco Firepower fabric:EthTargetEp:peerDn managed object property |
| G32 cfprFabricEthTargetEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.42.1.21 | Gauge32 | read-only | Cisco Firepower fabric:EthTargetEp:peerPortId managed object property |
| G32 cfprFabricEthTargetEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.42.1.22 | Gauge32 | read-only | Cisco Firepower fabric:EthTargetEp:peerSlotId managed object property |
| CFP cfprFabricEthTargetEpPortId | 1.3.6.1.4.1.9.9.826.1.26.42.1.23 | CfprFabricPIoEpPortId | read-only | Cisco Firepower fabric:EthTargetEp:portId managed object property |
| CFP cfprFabricEthTargetEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.42.1.24 | CfprFabricPIoEpSlotId | read-only | Cisco Firepower fabric:EthTargetEp:slotId managed object property |
| CFP cfprFabricEthTargetEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.42.1.25 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthTargetEp:switchId managed object property |
| CFP cfprFabricEthTargetEpTransport | 1.3.6.1.4.1.9.9.826.1.26.42.1.26 | CfprFabricEthTargetEpTransport | read-only | Cisco Firepower fabric:EthTargetEp:transport managed object property |
| CFP cfprFabricEthTargetEpType | 1.3.6.1.4.1.9.9.826.1.26.42.1.27 | CfprFabricTargetEpType | read-only | Cisco Firepower fabric:EthTargetEp:type managed object property |
| CFP cfprFabricEthTargetEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.42.1.28 | CfprFabricWarnings | read-only | Cisco Firepower fabric:EthTargetEp:warnings managed object property |
| cfprFabricEthVlanPcTable | 1.3.6.1.4.1.9.9.826.1.26.43 | not-accessible | Cisco Firepower fabric:EthVlanPc managed object table | |
| cfprFabricEthVlanPcEntry | 1.3.6.1.4.1.9.9.826.1.26.43.1 | not-accessible | Entry for the cfprFabricEthVlanPcTable table. | |
| CFP cfprFabricEthVlanPcInstanceId | 1.3.6.1.4.1.9.9.826.1.26.43.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthVlanPcDn | 1.3.6.1.4.1.9.9.826.1.26.43.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthVlanPc:dn managed object property |
| STR cfprFabricEthVlanPcRn | 1.3.6.1.4.1.9.9.826.1.26.43.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthVlanPc:rn managed object property |
| CFP cfprFabricEthVlanPcAdminSpeed | 1.3.6.1.4.1.9.9.826.1.26.43.1.4 | CfprPortEthAdminSpeed | read-only | Cisco Firepower fabric:EthVlanPc:adminSpeed managed object property |
| CFP cfprFabricEthVlanPcAdminState | 1.3.6.1.4.1.9.9.826.1.26.43.1.5 | CfprFabricCIoEpAdminState | read-only | Cisco Firepower fabric:EthVlanPc:adminState managed object property |
| STR cfprFabricEthVlanPcDescr | 1.3.6.1.4.1.9.9.826.1.26.43.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:EthVlanPc:descr managed object property |
| STR cfprFabricEthVlanPcEpDn | 1.3.6.1.4.1.9.9.826.1.26.43.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:EthVlanPc:epDn managed object property |
| UNS cfprFabricEthVlanPcFltAggr | 1.3.6.1.4.1.9.9.826.1.26.43.1.8 | Unsigned64 | read-only | Cisco Firepower fabric:EthVlanPc:fltAggr managed object property |
| CFP cfprFabricEthVlanPcIfRole | 1.3.6.1.4.1.9.9.826.1.26.43.1.9 | CfprFabricEstcPcIfRole | read-only | Cisco Firepower fabric:EthVlanPc:ifRole managed object property |
| CFP cfprFabricEthVlanPcIfType | 1.3.6.1.4.1.9.9.826.1.26.43.1.10 | CfprFabricCIoEpIfType | read-only | Cisco Firepower fabric:EthVlanPc:ifType managed object property |
| T/F cfprFabricEthVlanPcIsNative | 1.3.6.1.4.1.9.9.826.1.26.43.1.11 | TruthValue | read-only | Cisco Firepower fabric:EthVlanPc:isNative managed object property |
| CFP cfprFabricEthVlanPcLocale | 1.3.6.1.4.1.9.9.826.1.26.43.1.12 | CfprFabricExternalPcLocale | read-only | Cisco Firepower fabric:EthVlanPc:locale managed object property |
| STR cfprFabricEthVlanPcName | 1.3.6.1.4.1.9.9.826.1.26.43.1.13 | SnmpAdminString | read-only | Cisco Firepower fabric:EthVlanPc:name managed object property |
| CFP cfprFabricEthVlanPcOperSpeed | 1.3.6.1.4.1.9.9.826.1.26.43.1.14 | CfprPortEthSpeed | read-only | Cisco Firepower fabric:EthVlanPc:operSpeed managed object property |
| CFP cfprFabricEthVlanPcOperState | 1.3.6.1.4.1.9.9.826.1.26.43.1.15 | CfprNetworkPortOperState | read-only | Cisco Firepower fabric:EthVlanPc:operState managed object property |
| STR cfprFabricEthVlanPcPeerDn | 1.3.6.1.4.1.9.9.826.1.26.43.1.16 | SnmpAdminString | read-only | Cisco Firepower fabric:EthVlanPc:peerDn managed object property |
| G32 cfprFabricEthVlanPcPortId | 1.3.6.1.4.1.9.9.826.1.26.43.1.17 | Gauge32 | read-only | Cisco Firepower fabric:EthVlanPc:portId managed object property |
| STR cfprFabricEthVlanPcStateQual | 1.3.6.1.4.1.9.9.826.1.26.43.1.18 | SnmpAdminString | read-only | Cisco Firepower fabric:EthVlanPc:stateQual managed object property |
| CFP cfprFabricEthVlanPcSwitchId | 1.3.6.1.4.1.9.9.826.1.26.43.1.19 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthVlanPc:switchId managed object property |
| CFP cfprFabricEthVlanPcTransport | 1.3.6.1.4.1.9.9.826.1.26.43.1.20 | CfprFabricEthVlanPcTransport | read-only | Cisco Firepower fabric:EthVlanPc:transport managed object property |
| CFP cfprFabricEthVlanPcType | 1.3.6.1.4.1.9.9.826.1.26.43.1.21 | CfprFabricEstcPcType | read-only | Cisco Firepower fabric:EthVlanPc:type managed object property |
| CFP cfprFabricEthVlanPcWarnings | 1.3.6.1.4.1.9.9.826.1.26.43.1.22 | CfprFabricWarnings | read-only | Cisco Firepower fabric:EthVlanPc:warnings managed object property |
| cfprFabricEthVlanPortEpTable | 1.3.6.1.4.1.9.9.826.1.26.44 | not-accessible | Cisco Firepower fabric:EthVlanPortEp managed object table | |
| cfprFabricEthVlanPortEpEntry | 1.3.6.1.4.1.9.9.826.1.26.44.1 | not-accessible | Entry for the cfprFabricEthVlanPortEpTable table. | |
| CFP cfprFabricEthVlanPortEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.44.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricEthVlanPortEpDn | 1.3.6.1.4.1.9.9.826.1.26.44.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:EthVlanPortEp:dn managed object property |
| STR cfprFabricEthVlanPortEpRn | 1.3.6.1.4.1.9.9.826.1.26.44.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:EthVlanPortEp:rn managed object property |
| CFP cfprFabricEthVlanPortEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.44.1.4 | CfprFabricExternalEpAdminState | read-only | Cisco Firepower fabric:EthVlanPortEp:adminState managed object property |
| G32 cfprFabricEthVlanPortEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.44.1.5 | Gauge32 | read-only | Cisco Firepower fabric:EthVlanPortEp:aggrPortId managed object property |
| G32 cfprFabricEthVlanPortEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.44.1.6 | Gauge32 | read-only | Cisco Firepower fabric:EthVlanPortEp:chassisId managed object property |
| STR cfprFabricEthVlanPortEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.44.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:EthVlanPortEp:epDn managed object property |
| UNS cfprFabricEthVlanPortEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.44.1.8 | Unsigned64 | read-only | Cisco Firepower fabric:EthVlanPortEp:fltAggr managed object property |
| CFP cfprFabricEthVlanPortEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.44.1.9 | CfprFabricLanEpIfRole | read-only | Cisco Firepower fabric:EthVlanPortEp:ifRole managed object property |
| CFP cfprFabricEthVlanPortEpIfType | 1.3.6.1.4.1.9.9.826.1.26.44.1.10 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:EthVlanPortEp:ifType managed object property |
| T/F cfprFabricEthVlanPortEpIsNative | 1.3.6.1.4.1.9.9.826.1.26.44.1.11 | TruthValue | read-only | Cisco Firepower fabric:EthVlanPortEp:isNative managed object property |
| UNS cfprFabricEthVlanPortEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.44.1.12 | Unsigned64 | read-only | Cisco Firepower fabric:EthVlanPortEp:licGP managed object property |
| CFP cfprFabricEthVlanPortEpLicState | 1.3.6.1.4.1.9.9.826.1.26.44.1.13 | CfprLicenseState | read-only | Cisco Firepower fabric:EthVlanPortEp:licState managed object property |
| CFP cfprFabricEthVlanPortEpLocale | 1.3.6.1.4.1.9.9.826.1.26.44.1.14 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:EthVlanPortEp:locale managed object property |
| STR cfprFabricEthVlanPortEpName | 1.3.6.1.4.1.9.9.826.1.26.44.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:EthVlanPortEp:name managed object property |
| CFP cfprFabricEthVlanPortEpOperState | 1.3.6.1.4.1.9.9.826.1.26.44.1.16 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:EthVlanPortEp:operState managed object property |
| STR cfprFabricEthVlanPortEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.44.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:EthVlanPortEp:operStateReason managed object property |
| G32 cfprFabricEthVlanPortEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.44.1.18 | Gauge32 | read-only | Cisco Firepower fabric:EthVlanPortEp:peerAggrPortId managed object property |
| G32 cfprFabricEthVlanPortEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.44.1.19 | Gauge32 | read-only | Cisco Firepower fabric:EthVlanPortEp:peerChassisId managed object property |
| STR cfprFabricEthVlanPortEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.44.1.20 | SnmpAdminString | read-only | Cisco Firepower fabric:EthVlanPortEp:peerDn managed object property |
| G32 cfprFabricEthVlanPortEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.44.1.21 | Gauge32 | read-only | Cisco Firepower fabric:EthVlanPortEp:peerPortId managed object property |
| G32 cfprFabricEthVlanPortEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.44.1.22 | Gauge32 | read-only | Cisco Firepower fabric:EthVlanPortEp:peerSlotId managed object property |
| G32 cfprFabricEthVlanPortEpPortId | 1.3.6.1.4.1.9.9.826.1.26.44.1.23 | Gauge32 | read-only | Cisco Firepower fabric:EthVlanPortEp:portId managed object property |
| G32 cfprFabricEthVlanPortEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.44.1.24 | Gauge32 | read-only | Cisco Firepower fabric:EthVlanPortEp:slotId managed object property |
| CFP cfprFabricEthVlanPortEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.44.1.25 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:EthVlanPortEp:switchId managed object property |
| CFP cfprFabricEthVlanPortEpTransport | 1.3.6.1.4.1.9.9.826.1.26.44.1.26 | CfprFabricAEthLanEpTransport | read-only | Cisco Firepower fabric:EthVlanPortEp:transport managed object property |
| CFP cfprFabricEthVlanPortEpType | 1.3.6.1.4.1.9.9.826.1.26.44.1.27 | CfprFabricLanEpType | read-only | Cisco Firepower fabric:EthVlanPortEp:type managed object property |
| CFP cfprFabricEthVlanPortEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.44.1.28 | CfprFabricWarnings | read-only | Cisco Firepower fabric:EthVlanPortEp:warnings managed object property |
| cfprFabricFcSanTable | 1.3.6.1.4.1.9.9.826.1.26.55 | not-accessible | Cisco Firepower fabric:FcSan managed object table | |
| cfprFabricFcSanEntry | 1.3.6.1.4.1.9.9.826.1.26.55.1 | not-accessible | Entry for the cfprFabricFcSanTable table. | |
| CFP cfprFabricFcSanInstanceId | 1.3.6.1.4.1.9.9.826.1.26.55.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricFcSanDn | 1.3.6.1.4.1.9.9.826.1.26.55.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:FcSan:dn managed object property |
| STR cfprFabricFcSanRn | 1.3.6.1.4.1.9.9.826.1.26.55.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSan:rn managed object property |
| CFP cfprFabricFcSanId | 1.3.6.1.4.1.9.9.826.1.26.55.1.4 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:FcSan:id managed object property |
| CFP cfprFabricFcSanLocale | 1.3.6.1.4.1.9.9.826.1.26.55.1.5 | CfprFabricExternalLocale | read-only | Cisco Firepower fabric:FcSan:locale managed object property |
| STR cfprFabricFcSanName | 1.3.6.1.4.1.9.9.826.1.26.55.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSan:name managed object property |
| CFP cfprFabricFcSanTransport | 1.3.6.1.4.1.9.9.826.1.26.55.1.7 | CfprFabricFcSanTransport | read-only | Cisco Firepower fabric:FcSan:transport managed object property |
| CFP cfprFabricFcSanType | 1.3.6.1.4.1.9.9.826.1.26.55.1.8 | CfprFabricSanType | read-only | Cisco Firepower fabric:FcSan:type managed object property |
| CFP cfprFabricFcSanUplinkTrunking | 1.3.6.1.4.1.9.9.826.1.26.55.1.9 | CfprFabricFcSanUplinkTrunking | read-only | Cisco Firepower fabric:FcSan:uplinkTrunking managed object property |
| cfprFabricFcSanEpTable | 1.3.6.1.4.1.9.9.826.1.26.56 | not-accessible | Cisco Firepower fabric:FcSanEp managed object table | |
| cfprFabricFcSanEpEntry | 1.3.6.1.4.1.9.9.826.1.26.56.1 | not-accessible | Entry for the cfprFabricFcSanEpTable table. | |
| CFP cfprFabricFcSanEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.56.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricFcSanEpDn | 1.3.6.1.4.1.9.9.826.1.26.56.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:FcSanEp:dn managed object property |
| STR cfprFabricFcSanEpRn | 1.3.6.1.4.1.9.9.826.1.26.56.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanEp:rn managed object property |
| CFP cfprFabricFcSanEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.56.1.4 | CfprFabricExternalEpAdminState | read-only | Cisco Firepower fabric:FcSanEp:adminState managed object property |
| G32 cfprFabricFcSanEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.56.1.5 | Gauge32 | read-only | Cisco Firepower fabric:FcSanEp:aggrPortId managed object property |
| G32 cfprFabricFcSanEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.56.1.6 | Gauge32 | read-only | Cisco Firepower fabric:FcSanEp:chassisId managed object property |
| STR cfprFabricFcSanEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.56.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanEp:epDn managed object property |
| CFP cfprFabricFcSanEpFillPattern | 1.3.6.1.4.1.9.9.826.1.26.56.1.8 | CfprFabricFillPattern | read-only | Cisco Firepower fabric:FcSanEp:fillPattern managed object property |
| UNS cfprFabricFcSanEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.56.1.9 | Unsigned64 | read-only | Cisco Firepower fabric:FcSanEp:fltAggr managed object property |
| CFP cfprFabricFcSanEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.56.1.10 | CfprFabricSanEpIfRole | read-only | Cisco Firepower fabric:FcSanEp:ifRole managed object property |
| CFP cfprFabricFcSanEpIfType | 1.3.6.1.4.1.9.9.826.1.26.56.1.11 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:FcSanEp:ifType managed object property |
| UNS cfprFabricFcSanEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.56.1.12 | Unsigned64 | read-only | Cisco Firepower fabric:FcSanEp:licGP managed object property |
| CFP cfprFabricFcSanEpLicState | 1.3.6.1.4.1.9.9.826.1.26.56.1.13 | CfprLicenseState | read-only | Cisco Firepower fabric:FcSanEp:licState managed object property |
| CFP cfprFabricFcSanEpLocale | 1.3.6.1.4.1.9.9.826.1.26.56.1.14 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:FcSanEp:locale managed object property |
| STR cfprFabricFcSanEpName | 1.3.6.1.4.1.9.9.826.1.26.56.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanEp:name managed object property |
| CFP cfprFabricFcSanEpOperState | 1.3.6.1.4.1.9.9.826.1.26.56.1.16 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:FcSanEp:operState managed object property |
| STR cfprFabricFcSanEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.56.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanEp:operStateReason managed object property |
| G32 cfprFabricFcSanEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.56.1.18 | Gauge32 | read-only | Cisco Firepower fabric:FcSanEp:peerAggrPortId managed object property |
| G32 cfprFabricFcSanEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.56.1.19 | Gauge32 | read-only | Cisco Firepower fabric:FcSanEp:peerChassisId managed object property |
| STR cfprFabricFcSanEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.56.1.20 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanEp:peerDn managed object property |
| G32 cfprFabricFcSanEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.56.1.21 | Gauge32 | read-only | Cisco Firepower fabric:FcSanEp:peerPortId managed object property |
| G32 cfprFabricFcSanEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.56.1.22 | Gauge32 | read-only | Cisco Firepower fabric:FcSanEp:peerSlotId managed object property |
| CFP cfprFabricFcSanEpPortId | 1.3.6.1.4.1.9.9.826.1.26.56.1.23 | CfprFabricFcSanEpPortId | read-only | Cisco Firepower fabric:FcSanEp:portId managed object property |
| CFP cfprFabricFcSanEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.56.1.24 | CfprFabricFcSanEpSlotId | read-only | Cisco Firepower fabric:FcSanEp:slotId managed object property |
| CFP cfprFabricFcSanEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.56.1.25 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:FcSanEp:switchId managed object property |
| CFP cfprFabricFcSanEpTransport | 1.3.6.1.4.1.9.9.826.1.26.56.1.26 | CfprFabricAFcSanEpTransport | read-only | Cisco Firepower fabric:FcSanEp:transport managed object property |
| CFP cfprFabricFcSanEpType | 1.3.6.1.4.1.9.9.826.1.26.56.1.27 | CfprFabricSanEpType | read-only | Cisco Firepower fabric:FcSanEp:type managed object property |
| STR cfprFabricFcSanEpUsrLbl | 1.3.6.1.4.1.9.9.826.1.26.56.1.28 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanEp:usrLbl managed object property |
| CFP cfprFabricFcSanEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.56.1.29 | CfprFabricWarnings | read-only | Cisco Firepower fabric:FcSanEp:warnings managed object property |
| cfprFabricFcSanPcTable | 1.3.6.1.4.1.9.9.826.1.26.57 | not-accessible | Cisco Firepower fabric:FcSanPc managed object table | |
| cfprFabricFcSanPcEntry | 1.3.6.1.4.1.9.9.826.1.26.57.1 | not-accessible | Entry for the cfprFabricFcSanPcTable table. | |
| CFP cfprFabricFcSanPcInstanceId | 1.3.6.1.4.1.9.9.826.1.26.57.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricFcSanPcDn | 1.3.6.1.4.1.9.9.826.1.26.57.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:FcSanPc:dn managed object property |
| STR cfprFabricFcSanPcRn | 1.3.6.1.4.1.9.9.826.1.26.57.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanPc:rn managed object property |
| CFP cfprFabricFcSanPcAdminSpeed | 1.3.6.1.4.1.9.9.826.1.26.57.1.4 | CfprPortSpeed | read-only | Cisco Firepower fabric:FcSanPc:adminSpeed managed object property |
| CFP cfprFabricFcSanPcAdminState | 1.3.6.1.4.1.9.9.826.1.26.57.1.5 | CfprFabricCIoEpAdminState | read-only | Cisco Firepower fabric:FcSanPc:adminState managed object property |
| CFP cfprFabricFcSanPcConfigState | 1.3.6.1.4.1.9.9.826.1.26.57.1.6 | CfprFabricConfigState | read-only | Cisco Firepower fabric:FcSanPc:configState managed object property |
| CFP cfprFabricFcSanPcConfigStatus | 1.3.6.1.4.1.9.9.826.1.26.57.1.7 | CfprFabricPcConfigStatus | read-only | Cisco Firepower fabric:FcSanPc:configStatus managed object property |
| STR cfprFabricFcSanPcDescr | 1.3.6.1.4.1.9.9.826.1.26.57.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanPc:descr managed object property |
| STR cfprFabricFcSanPcEpDn | 1.3.6.1.4.1.9.9.826.1.26.57.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanPc:epDn managed object property |
| UNS cfprFabricFcSanPcFltAggr | 1.3.6.1.4.1.9.9.826.1.26.57.1.10 | Unsigned64 | read-only | Cisco Firepower fabric:FcSanPc:fltAggr managed object property |
| CFP cfprFabricFcSanPcIfRole | 1.3.6.1.4.1.9.9.826.1.26.57.1.11 | CfprFabricSanPcIfRole | read-only | Cisco Firepower fabric:FcSanPc:ifRole managed object property |
| CFP cfprFabricFcSanPcIfType | 1.3.6.1.4.1.9.9.826.1.26.57.1.12 | CfprFabricCIoEpIfType | read-only | Cisco Firepower fabric:FcSanPc:ifType managed object property |
| CFP cfprFabricFcSanPcLocale | 1.3.6.1.4.1.9.9.826.1.26.57.1.13 | CfprFabricExternalPcLocale | read-only | Cisco Firepower fabric:FcSanPc:locale managed object property |
| STR cfprFabricFcSanPcName | 1.3.6.1.4.1.9.9.826.1.26.57.1.14 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanPc:name managed object property |
| G32 cfprFabricFcSanPcOperSpeed | 1.3.6.1.4.1.9.9.826.1.26.57.1.15 | Gauge32 | read-only | Cisco Firepower fabric:FcSanPc:operSpeed managed object property |
| CFP cfprFabricFcSanPcOperState | 1.3.6.1.4.1.9.9.826.1.26.57.1.16 | CfprNetworkPortOperState | read-only | Cisco Firepower fabric:FcSanPc:operState managed object property |
| STR cfprFabricFcSanPcPeerDn | 1.3.6.1.4.1.9.9.826.1.26.57.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanPc:peerDn managed object property |
| G32 cfprFabricFcSanPcPortId | 1.3.6.1.4.1.9.9.826.1.26.57.1.18 | Gauge32 | read-only | Cisco Firepower fabric:FcSanPc:portId managed object property |
| STR cfprFabricFcSanPcStateQual | 1.3.6.1.4.1.9.9.826.1.26.57.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanPc:stateQual managed object property |
| CFP cfprFabricFcSanPcSwitchId | 1.3.6.1.4.1.9.9.826.1.26.57.1.20 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:FcSanPc:switchId managed object property |
| CFP cfprFabricFcSanPcTransport | 1.3.6.1.4.1.9.9.826.1.26.57.1.21 | CfprFabricFcSanPcTransport | read-only | Cisco Firepower fabric:FcSanPc:transport managed object property |
| CFP cfprFabricFcSanPcType | 1.3.6.1.4.1.9.9.826.1.26.57.1.22 | CfprFabricSanPcType | read-only | Cisco Firepower fabric:FcSanPc:type managed object property |
| CFP cfprFabricFcSanPcWarnings | 1.3.6.1.4.1.9.9.826.1.26.57.1.23 | CfprFabricWarnings | read-only | Cisco Firepower fabric:FcSanPc:warnings managed object property |
| cfprFabricFcSanPcEpTable | 1.3.6.1.4.1.9.9.826.1.26.58 | not-accessible | Cisco Firepower fabric:FcSanPcEp managed object table | |
| cfprFabricFcSanPcEpEntry | 1.3.6.1.4.1.9.9.826.1.26.58.1 | not-accessible | Entry for the cfprFabricFcSanPcEpTable table. | |
| CFP cfprFabricFcSanPcEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.58.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricFcSanPcEpDnData | 1.3.6.1.4.1.9.9.826.1.26.58.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:FcSanPcEp:dn managed object property |
| STR cfprFabricFcSanPcEpRn | 1.3.6.1.4.1.9.9.826.1.26.58.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanPcEp:rn managed object property |
| CFP cfprFabricFcSanPcEpAdminSpeed | 1.3.6.1.4.1.9.9.826.1.26.58.1.4 | CfprPortSpeed | read-only | Cisco Firepower fabric:FcSanPcEp:adminSpeed managed object property |
| CFP cfprFabricFcSanPcEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.58.1.5 | CfprFabricExternalEpAdminState | read-only | Cisco Firepower fabric:FcSanPcEp:adminState managed object property |
| G32 cfprFabricFcSanPcEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.58.1.6 | Gauge32 | read-only | Cisco Firepower fabric:FcSanPcEp:aggrPortId managed object property |
| G32 cfprFabricFcSanPcEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.58.1.7 | Gauge32 | read-only | Cisco Firepower fabric:FcSanPcEp:chassisId managed object property |
| STR cfprFabricFcSanPcEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.58.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanPcEp:epDn managed object property |
| CFP cfprFabricFcSanPcEpFillPattern | 1.3.6.1.4.1.9.9.826.1.26.58.1.9 | CfprFabricFillPattern | read-only | Cisco Firepower fabric:FcSanPcEp:fillPattern managed object property |
| UNS cfprFabricFcSanPcEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.58.1.10 | Unsigned64 | read-only | Cisco Firepower fabric:FcSanPcEp:fltAggr managed object property |
| CFP cfprFabricFcSanPcEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.58.1.11 | CfprFabricSanEpIfRole | read-only | Cisco Firepower fabric:FcSanPcEp:ifRole managed object property |
| CFP cfprFabricFcSanPcEpIfType | 1.3.6.1.4.1.9.9.826.1.26.58.1.12 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:FcSanPcEp:ifType managed object property |
| UNS cfprFabricFcSanPcEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.58.1.13 | Unsigned64 | read-only | Cisco Firepower fabric:FcSanPcEp:licGP managed object property |
| CFP cfprFabricFcSanPcEpLicState | 1.3.6.1.4.1.9.9.826.1.26.58.1.14 | CfprLicenseState | read-only | Cisco Firepower fabric:FcSanPcEp:licState managed object property |
| CFP cfprFabricFcSanPcEpLocale | 1.3.6.1.4.1.9.9.826.1.26.58.1.15 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:FcSanPcEp:locale managed object property |
| CFP cfprFabricFcSanPcEpMembership | 1.3.6.1.4.1.9.9.826.1.26.58.1.16 | CfprFabricMembershipStatus | read-only | Cisco Firepower fabric:FcSanPcEp:membership managed object property |
| STR cfprFabricFcSanPcEpName | 1.3.6.1.4.1.9.9.826.1.26.58.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanPcEp:name managed object property |
| CFP cfprFabricFcSanPcEpOperState | 1.3.6.1.4.1.9.9.826.1.26.58.1.18 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:FcSanPcEp:operState managed object property |
| STR cfprFabricFcSanPcEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.58.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanPcEp:operStateReason managed object property |
| G32 cfprFabricFcSanPcEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.58.1.20 | Gauge32 | read-only | Cisco Firepower fabric:FcSanPcEp:peerAggrPortId managed object property |
| G32 cfprFabricFcSanPcEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.58.1.21 | Gauge32 | read-only | Cisco Firepower fabric:FcSanPcEp:peerChassisId managed object property |
| STR cfprFabricFcSanPcEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.58.1.22 | SnmpAdminString | read-only | Cisco Firepower fabric:FcSanPcEp:peerDn managed object property |
| G32 cfprFabricFcSanPcEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.58.1.23 | Gauge32 | read-only | Cisco Firepower fabric:FcSanPcEp:peerPortId managed object property |
| G32 cfprFabricFcSanPcEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.58.1.24 | Gauge32 | read-only | Cisco Firepower fabric:FcSanPcEp:peerSlotId managed object property |
| CFP cfprFabricFcSanPcEpPortId | 1.3.6.1.4.1.9.9.826.1.26.58.1.25 | CfprFabricFcSanPcEpPortId | read-only | Cisco Firepower fabric:FcSanPcEp:portId managed object property |
| CFP cfprFabricFcSanPcEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.58.1.26 | CfprFabricFcSanPcEpSlotId | read-only | Cisco Firepower fabric:FcSanPcEp:slotId managed object property |
| CFP cfprFabricFcSanPcEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.58.1.27 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:FcSanPcEp:switchId managed object property |
| CFP cfprFabricFcSanPcEpTransport | 1.3.6.1.4.1.9.9.826.1.26.58.1.28 | CfprFabricAFcSanEpTransport | read-only | Cisco Firepower fabric:FcSanPcEp:transport managed object property |
| CFP cfprFabricFcSanPcEpType | 1.3.6.1.4.1.9.9.826.1.26.58.1.29 | CfprFabricSanEpType | read-only | Cisco Firepower fabric:FcSanPcEp:type managed object property |
| CFP cfprFabricFcSanPcEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.58.1.30 | CfprFabricWarnings | read-only | Cisco Firepower fabric:FcSanPcEp:warnings managed object property |
| cfprFabricFcVsanPcTable | 1.3.6.1.4.1.9.9.826.1.26.59 | not-accessible | Cisco Firepower fabric:FcVsanPc managed object table | |
| cfprFabricFcVsanPcEntry | 1.3.6.1.4.1.9.9.826.1.26.59.1 | not-accessible | Entry for the cfprFabricFcVsanPcTable table. | |
| CFP cfprFabricFcVsanPcInstanceId | 1.3.6.1.4.1.9.9.826.1.26.59.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricFcVsanPcDn | 1.3.6.1.4.1.9.9.826.1.26.59.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:FcVsanPc:dn managed object property |
| STR cfprFabricFcVsanPcRn | 1.3.6.1.4.1.9.9.826.1.26.59.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:FcVsanPc:rn managed object property |
| CFP cfprFabricFcVsanPcAdminState | 1.3.6.1.4.1.9.9.826.1.26.59.1.4 | CfprFabricCIoEpAdminState | read-only | Cisco Firepower fabric:FcVsanPc:adminState managed object property |
| STR cfprFabricFcVsanPcDescr | 1.3.6.1.4.1.9.9.826.1.26.59.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:FcVsanPc:descr managed object property |
| STR cfprFabricFcVsanPcEpDn | 1.3.6.1.4.1.9.9.826.1.26.59.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:FcVsanPc:epDn managed object property |
| UNS cfprFabricFcVsanPcFltAggr | 1.3.6.1.4.1.9.9.826.1.26.59.1.7 | Unsigned64 | read-only | Cisco Firepower fabric:FcVsanPc:fltAggr managed object property |
| CFP cfprFabricFcVsanPcIfRole | 1.3.6.1.4.1.9.9.826.1.26.59.1.8 | CfprFabricSanPcIfRole | read-only | Cisco Firepower fabric:FcVsanPc:ifRole managed object property |
| CFP cfprFabricFcVsanPcIfType | 1.3.6.1.4.1.9.9.826.1.26.59.1.9 | CfprFabricCIoEpIfType | read-only | Cisco Firepower fabric:FcVsanPc:ifType managed object property |
| CFP cfprFabricFcVsanPcLocale | 1.3.6.1.4.1.9.9.826.1.26.59.1.10 | CfprFabricExternalPcLocale | read-only | Cisco Firepower fabric:FcVsanPc:locale managed object property |
| STR cfprFabricFcVsanPcName | 1.3.6.1.4.1.9.9.826.1.26.59.1.11 | SnmpAdminString | read-only | Cisco Firepower fabric:FcVsanPc:name managed object property |
| CFP cfprFabricFcVsanPcOperState | 1.3.6.1.4.1.9.9.826.1.26.59.1.12 | CfprNetworkPortOperState | read-only | Cisco Firepower fabric:FcVsanPc:operState managed object property |
| STR cfprFabricFcVsanPcPeerDn | 1.3.6.1.4.1.9.9.826.1.26.59.1.13 | SnmpAdminString | read-only | Cisco Firepower fabric:FcVsanPc:peerDn managed object property |
| G32 cfprFabricFcVsanPcPortId | 1.3.6.1.4.1.9.9.826.1.26.59.1.14 | Gauge32 | read-only | Cisco Firepower fabric:FcVsanPc:portId managed object property |
| STR cfprFabricFcVsanPcStateQual | 1.3.6.1.4.1.9.9.826.1.26.59.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:FcVsanPc:stateQual managed object property |
| CFP cfprFabricFcVsanPcSwitchId | 1.3.6.1.4.1.9.9.826.1.26.59.1.16 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:FcVsanPc:switchId managed object property |
| CFP cfprFabricFcVsanPcTransport | 1.3.6.1.4.1.9.9.826.1.26.59.1.17 | CfprFabricFcVsanPcTransport | read-only | Cisco Firepower fabric:FcVsanPc:transport managed object property |
| CFP cfprFabricFcVsanPcType | 1.3.6.1.4.1.9.9.826.1.26.59.1.18 | CfprFabricSanPcType | read-only | Cisco Firepower fabric:FcVsanPc:type managed object property |
| CFP cfprFabricFcVsanPcWarnings | 1.3.6.1.4.1.9.9.826.1.26.59.1.19 | CfprFabricWarnings | read-only | Cisco Firepower fabric:FcVsanPc:warnings managed object property |
| cfprFabricFcVsanPortEpTable | 1.3.6.1.4.1.9.9.826.1.26.60 | not-accessible | Cisco Firepower fabric:FcVsanPortEp managed object table | |
| cfprFabricFcVsanPortEpEntry | 1.3.6.1.4.1.9.9.826.1.26.60.1 | not-accessible | Entry for the cfprFabricFcVsanPortEpTable table. | |
| CFP cfprFabricFcVsanPortEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.60.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricFcVsanPortEpDn | 1.3.6.1.4.1.9.9.826.1.26.60.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:FcVsanPortEp:dn managed object property |
| STR cfprFabricFcVsanPortEpRn | 1.3.6.1.4.1.9.9.826.1.26.60.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:FcVsanPortEp:rn managed object property |
| CFP cfprFabricFcVsanPortEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.60.1.4 | CfprFabricExternalEpAdminState | read-only | Cisco Firepower fabric:FcVsanPortEp:adminState managed object property |
| G32 cfprFabricFcVsanPortEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.60.1.5 | Gauge32 | read-only | Cisco Firepower fabric:FcVsanPortEp:aggrPortId managed object property |
| G32 cfprFabricFcVsanPortEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.60.1.6 | Gauge32 | read-only | Cisco Firepower fabric:FcVsanPortEp:chassisId managed object property |
| STR cfprFabricFcVsanPortEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.60.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:FcVsanPortEp:epDn managed object property |
| UNS cfprFabricFcVsanPortEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.60.1.8 | Unsigned64 | read-only | Cisco Firepower fabric:FcVsanPortEp:fltAggr managed object property |
| CFP cfprFabricFcVsanPortEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.60.1.9 | CfprFabricSanEpIfRole | read-only | Cisco Firepower fabric:FcVsanPortEp:ifRole managed object property |
| CFP cfprFabricFcVsanPortEpIfType | 1.3.6.1.4.1.9.9.826.1.26.60.1.10 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:FcVsanPortEp:ifType managed object property |
| UNS cfprFabricFcVsanPortEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.60.1.11 | Unsigned64 | read-only | Cisco Firepower fabric:FcVsanPortEp:licGP managed object property |
| CFP cfprFabricFcVsanPortEpLicState | 1.3.6.1.4.1.9.9.826.1.26.60.1.12 | CfprLicenseState | read-only | Cisco Firepower fabric:FcVsanPortEp:licState managed object property |
| CFP cfprFabricFcVsanPortEpLocale | 1.3.6.1.4.1.9.9.826.1.26.60.1.13 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:FcVsanPortEp:locale managed object property |
| STR cfprFabricFcVsanPortEpName | 1.3.6.1.4.1.9.9.826.1.26.60.1.14 | SnmpAdminString | read-only | Cisco Firepower fabric:FcVsanPortEp:name managed object property |
| CFP cfprFabricFcVsanPortEpOperState | 1.3.6.1.4.1.9.9.826.1.26.60.1.15 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:FcVsanPortEp:operState managed object property |
| STR cfprFabricFcVsanPortEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.60.1.16 | SnmpAdminString | read-only | Cisco Firepower fabric:FcVsanPortEp:operStateReason managed object property |
| G32 cfprFabricFcVsanPortEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.60.1.17 | Gauge32 | read-only | Cisco Firepower fabric:FcVsanPortEp:peerAggrPortId managed object property |
| G32 cfprFabricFcVsanPortEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.60.1.18 | Gauge32 | read-only | Cisco Firepower fabric:FcVsanPortEp:peerChassisId managed object property |
| STR cfprFabricFcVsanPortEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.60.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:FcVsanPortEp:peerDn managed object property |
| G32 cfprFabricFcVsanPortEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.60.1.20 | Gauge32 | read-only | Cisco Firepower fabric:FcVsanPortEp:peerPortId managed object property |
| G32 cfprFabricFcVsanPortEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.60.1.21 | Gauge32 | read-only | Cisco Firepower fabric:FcVsanPortEp:peerSlotId managed object property |
| CFP cfprFabricFcVsanPortEpPortId | 1.3.6.1.4.1.9.9.826.1.26.60.1.22 | CfprFabricFcVsanPortEpPortId | read-only | Cisco Firepower fabric:FcVsanPortEp:portId managed object property |
| CFP cfprFabricFcVsanPortEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.60.1.23 | CfprFabricFcVsanPortEpSlotId | read-only | Cisco Firepower fabric:FcVsanPortEp:slotId managed object property |
| CFP cfprFabricFcVsanPortEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.60.1.24 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:FcVsanPortEp:switchId managed object property |
| CFP cfprFabricFcVsanPortEpTransport | 1.3.6.1.4.1.9.9.826.1.26.60.1.25 | CfprFabricAFcSanEpTransport | read-only | Cisco Firepower fabric:FcVsanPortEp:transport managed object property |
| CFP cfprFabricFcVsanPortEpType | 1.3.6.1.4.1.9.9.826.1.26.60.1.26 | CfprFabricSanEpType | read-only | Cisco Firepower fabric:FcVsanPortEp:type managed object property |
| CFP cfprFabricFcVsanPortEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.60.1.27 | CfprFabricWarnings | read-only | Cisco Firepower fabric:FcVsanPortEp:warnings managed object property |
| cfprFabricFcoeSanEpTable | 1.3.6.1.4.1.9.9.826.1.26.62 | not-accessible | Cisco Firepower fabric:FcoeSanEp managed object table | |
| cfprFabricFcoeSanEpEntry | 1.3.6.1.4.1.9.9.826.1.26.62.1 | not-accessible | Entry for the cfprFabricFcoeSanEpTable table. | |
| CFP cfprFabricFcoeSanEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.62.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricFcoeSanEpDn | 1.3.6.1.4.1.9.9.826.1.26.62.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:FcoeSanEp:dn managed object property |
| STR cfprFabricFcoeSanEpRn | 1.3.6.1.4.1.9.9.826.1.26.62.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanEp:rn managed object property |
| CFP cfprFabricFcoeSanEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.62.1.4 | CfprFabricExternalEpAdminState | read-only | Cisco Firepower fabric:FcoeSanEp:adminState managed object property |
| G32 cfprFabricFcoeSanEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.62.1.5 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanEp:aggrPortId managed object property |
| G32 cfprFabricFcoeSanEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.62.1.6 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanEp:chassisId managed object property |
| CFP cfprFabricFcoeSanEpConfigState | 1.3.6.1.4.1.9.9.826.1.26.62.1.7 | CfprFabricConfigState | read-only | Cisco Firepower fabric:FcoeSanEp:configState managed object property |
| STR cfprFabricFcoeSanEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.62.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanEp:epDn managed object property |
| STR cfprFabricFcoeSanEpEthLinkProfileName | 1.3.6.1.4.1.9.9.826.1.26.62.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanEp:ethLinkProfileName managed object property |
| CFP cfprFabricFcoeSanEpFcoeState | 1.3.6.1.4.1.9.9.826.1.26.62.1.10 | CfprNetworkPortOperState | read-only | Cisco Firepower fabric:FcoeSanEp:fcoeState managed object property |
| STR cfprFabricFcoeSanEpFcoeStateReason | 1.3.6.1.4.1.9.9.826.1.26.62.1.11 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanEp:fcoeStateReason managed object property |
| UNS cfprFabricFcoeSanEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.62.1.12 | Unsigned64 | read-only | Cisco Firepower fabric:FcoeSanEp:fltAggr managed object property |
| CFP cfprFabricFcoeSanEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.62.1.13 | CfprFabricSanEpIfRole | read-only | Cisco Firepower fabric:FcoeSanEp:ifRole managed object property |
| CFP cfprFabricFcoeSanEpIfType | 1.3.6.1.4.1.9.9.826.1.26.62.1.14 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:FcoeSanEp:ifType managed object property |
| UNS cfprFabricFcoeSanEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.62.1.15 | Unsigned64 | read-only | Cisco Firepower fabric:FcoeSanEp:licGP managed object property |
| CFP cfprFabricFcoeSanEpLicState | 1.3.6.1.4.1.9.9.826.1.26.62.1.16 | CfprLicenseState | read-only | Cisco Firepower fabric:FcoeSanEp:licState managed object property |
| CFP cfprFabricFcoeSanEpLocale | 1.3.6.1.4.1.9.9.826.1.26.62.1.17 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:FcoeSanEp:locale managed object property |
| STR cfprFabricFcoeSanEpName | 1.3.6.1.4.1.9.9.826.1.26.62.1.18 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanEp:name managed object property |
| STR cfprFabricFcoeSanEpOperEthLinkProfileName | 1.3.6.1.4.1.9.9.826.1.26.62.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanEp:operEthLinkProfileName managed object property |
| CFP cfprFabricFcoeSanEpOperState | 1.3.6.1.4.1.9.9.826.1.26.62.1.20 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:FcoeSanEp:operState managed object property |
| STR cfprFabricFcoeSanEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.62.1.21 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanEp:operStateReason managed object property |
| G32 cfprFabricFcoeSanEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.62.1.22 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanEp:peerAggrPortId managed object property |
| G32 cfprFabricFcoeSanEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.62.1.23 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanEp:peerChassisId managed object property |
| STR cfprFabricFcoeSanEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.62.1.24 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanEp:peerDn managed object property |
| G32 cfprFabricFcoeSanEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.62.1.25 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanEp:peerPortId managed object property |
| G32 cfprFabricFcoeSanEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.62.1.26 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanEp:peerSlotId managed object property |
| CFP cfprFabricFcoeSanEpPortId | 1.3.6.1.4.1.9.9.826.1.26.62.1.27 | CfprFabricFcoeSanEpPortId | read-only | Cisco Firepower fabric:FcoeSanEp:portId managed object property |
| CFP cfprFabricFcoeSanEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.62.1.28 | CfprFabricFcoeSanEpSlotId | read-only | Cisco Firepower fabric:FcoeSanEp:slotId managed object property |
| CFP cfprFabricFcoeSanEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.62.1.29 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:FcoeSanEp:switchId managed object property |
| CFP cfprFabricFcoeSanEpTransport | 1.3.6.1.4.1.9.9.826.1.26.62.1.30 | CfprFabricAFcoeSanEpTransport | read-only | Cisco Firepower fabric:FcoeSanEp:transport managed object property |
| CFP cfprFabricFcoeSanEpType | 1.3.6.1.4.1.9.9.826.1.26.62.1.31 | CfprFabricSanEpType | read-only | Cisco Firepower fabric:FcoeSanEp:type managed object property |
| CFP cfprFabricFcoeSanEpUdldOperState | 1.3.6.1.4.1.9.9.826.1.26.62.1.32 | CfprFabricUdldOperState | read-only | Cisco Firepower fabric:FcoeSanEp:udldOperState managed object property |
| STR cfprFabricFcoeSanEpUsrLbl | 1.3.6.1.4.1.9.9.826.1.26.62.1.33 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanEp:usrLbl managed object property |
| CFP cfprFabricFcoeSanEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.62.1.34 | CfprFabricWarnings | read-only | Cisco Firepower fabric:FcoeSanEp:warnings managed object property |
| cfprFabricFcoeSanPcTable | 1.3.6.1.4.1.9.9.826.1.26.63 | not-accessible | Cisco Firepower fabric:FcoeSanPc managed object table | |
| cfprFabricFcoeSanPcEntry | 1.3.6.1.4.1.9.9.826.1.26.63.1 | not-accessible | Entry for the cfprFabricFcoeSanPcTable table. | |
| CFP cfprFabricFcoeSanPcInstanceId | 1.3.6.1.4.1.9.9.826.1.26.63.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricFcoeSanPcDn | 1.3.6.1.4.1.9.9.826.1.26.63.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:FcoeSanPc:dn managed object property |
| STR cfprFabricFcoeSanPcRn | 1.3.6.1.4.1.9.9.826.1.26.63.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPc:rn managed object property |
| CFP cfprFabricFcoeSanPcAdminState | 1.3.6.1.4.1.9.9.826.1.26.63.1.4 | CfprFabricCIoEpAdminState | read-only | Cisco Firepower fabric:FcoeSanPc:adminState managed object property |
| CFP cfprFabricFcoeSanPcConfigState | 1.3.6.1.4.1.9.9.826.1.26.63.1.5 | CfprFabricConfigState | read-only | Cisco Firepower fabric:FcoeSanPc:configState managed object property |
| STR cfprFabricFcoeSanPcDescr | 1.3.6.1.4.1.9.9.826.1.26.63.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPc:descr managed object property |
| STR cfprFabricFcoeSanPcEpDn | 1.3.6.1.4.1.9.9.826.1.26.63.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPc:epDn managed object property |
| CFP cfprFabricFcoeSanPcFcoeState | 1.3.6.1.4.1.9.9.826.1.26.63.1.8 | CfprNetworkPortOperState | read-only | Cisco Firepower fabric:FcoeSanPc:fcoeState managed object property |
| STR cfprFabricFcoeSanPcFcoeStateReason | 1.3.6.1.4.1.9.9.826.1.26.63.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPc:fcoeStateReason managed object property |
| UNS cfprFabricFcoeSanPcFltAggr | 1.3.6.1.4.1.9.9.826.1.26.63.1.10 | Unsigned64 | read-only | Cisco Firepower fabric:FcoeSanPc:fltAggr managed object property |
| CFP cfprFabricFcoeSanPcIfRole | 1.3.6.1.4.1.9.9.826.1.26.63.1.11 | CfprFabricSanPcIfRole | read-only | Cisco Firepower fabric:FcoeSanPc:ifRole managed object property |
| CFP cfprFabricFcoeSanPcIfType | 1.3.6.1.4.1.9.9.826.1.26.63.1.12 | CfprFabricCIoEpIfType | read-only | Cisco Firepower fabric:FcoeSanPc:ifType managed object property |
| STR cfprFabricFcoeSanPcLacpPolicyName | 1.3.6.1.4.1.9.9.826.1.26.63.1.13 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPc:lacpPolicyName managed object property |
| CFP cfprFabricFcoeSanPcLocale | 1.3.6.1.4.1.9.9.826.1.26.63.1.14 | CfprFabricExternalPcLocale | read-only | Cisco Firepower fabric:FcoeSanPc:locale managed object property |
| STR cfprFabricFcoeSanPcName | 1.3.6.1.4.1.9.9.826.1.26.63.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPc:name managed object property |
| STR cfprFabricFcoeSanPcOperLacpPolicyName | 1.3.6.1.4.1.9.9.826.1.26.63.1.16 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPc:operLacpPolicyName managed object property |
| CFP cfprFabricFcoeSanPcOperState | 1.3.6.1.4.1.9.9.826.1.26.63.1.17 | CfprNetworkPortOperState | read-only | Cisco Firepower fabric:FcoeSanPc:operState managed object property |
| STR cfprFabricFcoeSanPcPeerDn | 1.3.6.1.4.1.9.9.826.1.26.63.1.18 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPc:peerDn managed object property |
| G32 cfprFabricFcoeSanPcPortId | 1.3.6.1.4.1.9.9.826.1.26.63.1.19 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanPc:portId managed object property |
| STR cfprFabricFcoeSanPcStateQual | 1.3.6.1.4.1.9.9.826.1.26.63.1.20 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPc:stateQual managed object property |
| CFP cfprFabricFcoeSanPcSwitchId | 1.3.6.1.4.1.9.9.826.1.26.63.1.21 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:FcoeSanPc:switchId managed object property |
| CFP cfprFabricFcoeSanPcTransport | 1.3.6.1.4.1.9.9.826.1.26.63.1.22 | CfprFabricFcoeSanPcTransport | read-only | Cisco Firepower fabric:FcoeSanPc:transport managed object property |
| CFP cfprFabricFcoeSanPcType | 1.3.6.1.4.1.9.9.826.1.26.63.1.23 | CfprFabricSanPcType | read-only | Cisco Firepower fabric:FcoeSanPc:type managed object property |
| CFP cfprFabricFcoeSanPcWarnings | 1.3.6.1.4.1.9.9.826.1.26.63.1.24 | CfprFabricWarnings | read-only | Cisco Firepower fabric:FcoeSanPc:warnings managed object property |
| cfprFabricFcoeSanPcEpTable | 1.3.6.1.4.1.9.9.826.1.26.64 | not-accessible | Cisco Firepower fabric:FcoeSanPcEp managed object table | |
| cfprFabricFcoeSanPcEpEntry | 1.3.6.1.4.1.9.9.826.1.26.64.1 | not-accessible | Entry for the cfprFabricFcoeSanPcEpTable table. | |
| CFP cfprFabricFcoeSanPcEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.64.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricFcoeSanPcEpDnData | 1.3.6.1.4.1.9.9.826.1.26.64.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:FcoeSanPcEp:dn managed object property |
| STR cfprFabricFcoeSanPcEpRn | 1.3.6.1.4.1.9.9.826.1.26.64.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPcEp:rn managed object property |
| CFP cfprFabricFcoeSanPcEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.64.1.4 | CfprFabricExternalEpAdminState | read-only | Cisco Firepower fabric:FcoeSanPcEp:adminState managed object property |
| G32 cfprFabricFcoeSanPcEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.64.1.5 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanPcEp:aggrPortId managed object property |
| G32 cfprFabricFcoeSanPcEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.64.1.6 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanPcEp:chassisId managed object property |
| STR cfprFabricFcoeSanPcEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.64.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPcEp:epDn managed object property |
| STR cfprFabricFcoeSanPcEpEthLinkProfileName | 1.3.6.1.4.1.9.9.826.1.26.64.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPcEp:ethLinkProfileName managed object property |
| UNS cfprFabricFcoeSanPcEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.64.1.9 | Unsigned64 | read-only | Cisco Firepower fabric:FcoeSanPcEp:fltAggr managed object property |
| CFP cfprFabricFcoeSanPcEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.64.1.10 | CfprFabricSanEpIfRole | read-only | Cisco Firepower fabric:FcoeSanPcEp:ifRole managed object property |
| CFP cfprFabricFcoeSanPcEpIfType | 1.3.6.1.4.1.9.9.826.1.26.64.1.11 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:FcoeSanPcEp:ifType managed object property |
| UNS cfprFabricFcoeSanPcEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.64.1.12 | Unsigned64 | read-only | Cisco Firepower fabric:FcoeSanPcEp:licGP managed object property |
| CFP cfprFabricFcoeSanPcEpLicState | 1.3.6.1.4.1.9.9.826.1.26.64.1.13 | CfprLicenseState | read-only | Cisco Firepower fabric:FcoeSanPcEp:licState managed object property |
| CFP cfprFabricFcoeSanPcEpLocale | 1.3.6.1.4.1.9.9.826.1.26.64.1.14 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:FcoeSanPcEp:locale managed object property |
| CFP cfprFabricFcoeSanPcEpMembership | 1.3.6.1.4.1.9.9.826.1.26.64.1.15 | CfprFabricMembershipStatus | read-only | Cisco Firepower fabric:FcoeSanPcEp:membership managed object property |
| STR cfprFabricFcoeSanPcEpName | 1.3.6.1.4.1.9.9.826.1.26.64.1.16 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPcEp:name managed object property |
| STR cfprFabricFcoeSanPcEpOperEthLinkProfileName | 1.3.6.1.4.1.9.9.826.1.26.64.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPcEp:operEthLinkProfileName managed object property |
| CFP cfprFabricFcoeSanPcEpOperState | 1.3.6.1.4.1.9.9.826.1.26.64.1.18 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:FcoeSanPcEp:operState managed object property |
| STR cfprFabricFcoeSanPcEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.64.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPcEp:operStateReason managed object property |
| G32 cfprFabricFcoeSanPcEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.64.1.20 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanPcEp:peerAggrPortId managed object property |
| G32 cfprFabricFcoeSanPcEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.64.1.21 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanPcEp:peerChassisId managed object property |
| STR cfprFabricFcoeSanPcEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.64.1.22 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeSanPcEp:peerDn managed object property |
| G32 cfprFabricFcoeSanPcEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.64.1.23 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanPcEp:peerPortId managed object property |
| G32 cfprFabricFcoeSanPcEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.64.1.24 | Gauge32 | read-only | Cisco Firepower fabric:FcoeSanPcEp:peerSlotId managed object property |
| CFP cfprFabricFcoeSanPcEpPortId | 1.3.6.1.4.1.9.9.826.1.26.64.1.25 | CfprFabricFcoeSanPcEpPortId | read-only | Cisco Firepower fabric:FcoeSanPcEp:portId managed object property |
| CFP cfprFabricFcoeSanPcEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.64.1.26 | CfprFabricFcoeSanPcEpSlotId | read-only | Cisco Firepower fabric:FcoeSanPcEp:slotId managed object property |
| CFP cfprFabricFcoeSanPcEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.64.1.27 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:FcoeSanPcEp:switchId managed object property |
| CFP cfprFabricFcoeSanPcEpTransport | 1.3.6.1.4.1.9.9.826.1.26.64.1.28 | CfprFabricAFcoeSanEpTransport | read-only | Cisco Firepower fabric:FcoeSanPcEp:transport managed object property |
| CFP cfprFabricFcoeSanPcEpType | 1.3.6.1.4.1.9.9.826.1.26.64.1.29 | CfprFabricSanEpType | read-only | Cisco Firepower fabric:FcoeSanPcEp:type managed object property |
| CFP cfprFabricFcoeSanPcEpUdldOperState | 1.3.6.1.4.1.9.9.826.1.26.64.1.30 | CfprFabricUdldOperState | read-only | Cisco Firepower fabric:FcoeSanPcEp:udldOperState managed object property |
| CFP cfprFabricFcoeSanPcEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.64.1.31 | CfprFabricWarnings | read-only | Cisco Firepower fabric:FcoeSanPcEp:warnings managed object property |
| cfprFabricFcoeVsanPcTable | 1.3.6.1.4.1.9.9.826.1.26.65 | not-accessible | Cisco Firepower fabric:FcoeVsanPc managed object table | |
| cfprFabricFcoeVsanPcEntry | 1.3.6.1.4.1.9.9.826.1.26.65.1 | not-accessible | Entry for the cfprFabricFcoeVsanPcTable table. | |
| CFP cfprFabricFcoeVsanPcInstanceId | 1.3.6.1.4.1.9.9.826.1.26.65.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricFcoeVsanPcDn | 1.3.6.1.4.1.9.9.826.1.26.65.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:FcoeVsanPc:dn managed object property |
| STR cfprFabricFcoeVsanPcRn | 1.3.6.1.4.1.9.9.826.1.26.65.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeVsanPc:rn managed object property |
| CFP cfprFabricFcoeVsanPcAdminState | 1.3.6.1.4.1.9.9.826.1.26.65.1.4 | CfprFabricCIoEpAdminState | read-only | Cisco Firepower fabric:FcoeVsanPc:adminState managed object property |
| STR cfprFabricFcoeVsanPcDescr | 1.3.6.1.4.1.9.9.826.1.26.65.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeVsanPc:descr managed object property |
| STR cfprFabricFcoeVsanPcEpDn | 1.3.6.1.4.1.9.9.826.1.26.65.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeVsanPc:epDn managed object property |
| UNS cfprFabricFcoeVsanPcFltAggr | 1.3.6.1.4.1.9.9.826.1.26.65.1.7 | Unsigned64 | read-only | Cisco Firepower fabric:FcoeVsanPc:fltAggr managed object property |
| CFP cfprFabricFcoeVsanPcIfRole | 1.3.6.1.4.1.9.9.826.1.26.65.1.8 | CfprFabricSanPcIfRole | read-only | Cisco Firepower fabric:FcoeVsanPc:ifRole managed object property |
| CFP cfprFabricFcoeVsanPcIfType | 1.3.6.1.4.1.9.9.826.1.26.65.1.9 | CfprFabricCIoEpIfType | read-only | Cisco Firepower fabric:FcoeVsanPc:ifType managed object property |
| CFP cfprFabricFcoeVsanPcLocale | 1.3.6.1.4.1.9.9.826.1.26.65.1.10 | CfprFabricExternalPcLocale | read-only | Cisco Firepower fabric:FcoeVsanPc:locale managed object property |
| STR cfprFabricFcoeVsanPcName | 1.3.6.1.4.1.9.9.826.1.26.65.1.11 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeVsanPc:name managed object property |
| CFP cfprFabricFcoeVsanPcOperState | 1.3.6.1.4.1.9.9.826.1.26.65.1.12 | CfprNetworkPortOperState | read-only | Cisco Firepower fabric:FcoeVsanPc:operState managed object property |
| STR cfprFabricFcoeVsanPcPeerDn | 1.3.6.1.4.1.9.9.826.1.26.65.1.13 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeVsanPc:peerDn managed object property |
| G32 cfprFabricFcoeVsanPcPortId | 1.3.6.1.4.1.9.9.826.1.26.65.1.14 | Gauge32 | read-only | Cisco Firepower fabric:FcoeVsanPc:portId managed object property |
| STR cfprFabricFcoeVsanPcStateQual | 1.3.6.1.4.1.9.9.826.1.26.65.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeVsanPc:stateQual managed object property |
| CFP cfprFabricFcoeVsanPcSwitchId | 1.3.6.1.4.1.9.9.826.1.26.65.1.16 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:FcoeVsanPc:switchId managed object property |
| CFP cfprFabricFcoeVsanPcTransport | 1.3.6.1.4.1.9.9.826.1.26.65.1.17 | CfprFabricFcoeVsanPcTransport | read-only | Cisco Firepower fabric:FcoeVsanPc:transport managed object property |
| CFP cfprFabricFcoeVsanPcType | 1.3.6.1.4.1.9.9.826.1.26.65.1.18 | CfprFabricSanPcType | read-only | Cisco Firepower fabric:FcoeVsanPc:type managed object property |
| CFP cfprFabricFcoeVsanPcWarnings | 1.3.6.1.4.1.9.9.826.1.26.65.1.19 | CfprFabricWarnings | read-only | Cisco Firepower fabric:FcoeVsanPc:warnings managed object property |
| cfprFabricFcoeVsanPortEpTable | 1.3.6.1.4.1.9.9.826.1.26.66 | not-accessible | Cisco Firepower fabric:FcoeVsanPortEp managed object table | |
| cfprFabricFcoeVsanPortEpEntry | 1.3.6.1.4.1.9.9.826.1.26.66.1 | not-accessible | Entry for the cfprFabricFcoeVsanPortEpTable table. | |
| CFP cfprFabricFcoeVsanPortEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.66.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricFcoeVsanPortEpDn | 1.3.6.1.4.1.9.9.826.1.26.66.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:FcoeVsanPortEp:dn managed object property |
| STR cfprFabricFcoeVsanPortEpRn | 1.3.6.1.4.1.9.9.826.1.26.66.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeVsanPortEp:rn managed object property |
| CFP cfprFabricFcoeVsanPortEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.66.1.4 | CfprFabricExternalEpAdminState | read-only | Cisco Firepower fabric:FcoeVsanPortEp:adminState managed object property |
| G32 cfprFabricFcoeVsanPortEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.66.1.5 | Gauge32 | read-only | Cisco Firepower fabric:FcoeVsanPortEp:aggrPortId managed object property |
| G32 cfprFabricFcoeVsanPortEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.66.1.6 | Gauge32 | read-only | Cisco Firepower fabric:FcoeVsanPortEp:chassisId managed object property |
| STR cfprFabricFcoeVsanPortEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.66.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeVsanPortEp:epDn managed object property |
| UNS cfprFabricFcoeVsanPortEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.66.1.8 | Unsigned64 | read-only | Cisco Firepower fabric:FcoeVsanPortEp:fltAggr managed object property |
| CFP cfprFabricFcoeVsanPortEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.66.1.9 | CfprFabricSanEpIfRole | read-only | Cisco Firepower fabric:FcoeVsanPortEp:ifRole managed object property |
| CFP cfprFabricFcoeVsanPortEpIfType | 1.3.6.1.4.1.9.9.826.1.26.66.1.10 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:FcoeVsanPortEp:ifType managed object property |
| UNS cfprFabricFcoeVsanPortEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.66.1.11 | Unsigned64 | read-only | Cisco Firepower fabric:FcoeVsanPortEp:licGP managed object property |
| CFP cfprFabricFcoeVsanPortEpLicState | 1.3.6.1.4.1.9.9.826.1.26.66.1.12 | CfprLicenseState | read-only | Cisco Firepower fabric:FcoeVsanPortEp:licState managed object property |
| CFP cfprFabricFcoeVsanPortEpLocale | 1.3.6.1.4.1.9.9.826.1.26.66.1.13 | CfprFabricExternalEpLocale | read-only | Cisco Firepower fabric:FcoeVsanPortEp:locale managed object property |
| STR cfprFabricFcoeVsanPortEpName | 1.3.6.1.4.1.9.9.826.1.26.66.1.14 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeVsanPortEp:name managed object property |
| CFP cfprFabricFcoeVsanPortEpOperState | 1.3.6.1.4.1.9.9.826.1.26.66.1.15 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:FcoeVsanPortEp:operState managed object property |
| STR cfprFabricFcoeVsanPortEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.66.1.16 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeVsanPortEp:operStateReason managed object property |
| G32 cfprFabricFcoeVsanPortEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.66.1.17 | Gauge32 | read-only | Cisco Firepower fabric:FcoeVsanPortEp:peerAggrPortId managed object property |
| G32 cfprFabricFcoeVsanPortEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.66.1.18 | Gauge32 | read-only | Cisco Firepower fabric:FcoeVsanPortEp:peerChassisId managed object property |
| STR cfprFabricFcoeVsanPortEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.66.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:FcoeVsanPortEp:peerDn managed object property |
| G32 cfprFabricFcoeVsanPortEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.66.1.20 | Gauge32 | read-only | Cisco Firepower fabric:FcoeVsanPortEp:peerPortId managed object property |
| G32 cfprFabricFcoeVsanPortEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.66.1.21 | Gauge32 | read-only | Cisco Firepower fabric:FcoeVsanPortEp:peerSlotId managed object property |
| CFP cfprFabricFcoeVsanPortEpPortId | 1.3.6.1.4.1.9.9.826.1.26.66.1.22 | CfprFabricFcoeVsanPortEpPortId | read-only | Cisco Firepower fabric:FcoeVsanPortEp:portId managed object property |
| CFP cfprFabricFcoeVsanPortEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.66.1.23 | CfprFabricFcoeVsanPortEpSlotId | read-only | Cisco Firepower fabric:FcoeVsanPortEp:slotId managed object property |
| CFP cfprFabricFcoeVsanPortEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.66.1.24 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:FcoeVsanPortEp:switchId managed object property |
| CFP cfprFabricFcoeVsanPortEpTransport | 1.3.6.1.4.1.9.9.826.1.26.66.1.25 | CfprFabricAFcSanEpTransport | read-only | Cisco Firepower fabric:FcoeVsanPortEp:transport managed object property |
| CFP cfprFabricFcoeVsanPortEpType | 1.3.6.1.4.1.9.9.826.1.26.66.1.26 | CfprFabricSanEpType | read-only | Cisco Firepower fabric:FcoeVsanPortEp:type managed object property |
| CFP cfprFabricFcoeVsanPortEpWarnings | 1.3.6.1.4.1.9.9.826.1.26.66.1.27 | CfprFabricWarnings | read-only | Cisco Firepower fabric:FcoeVsanPortEp:warnings managed object property |
| cfprFabricIfTable | 1.3.6.1.4.1.9.9.826.1.26.69 | not-accessible | Cisco Firepower fabric:If managed object table | |
| cfprFabricIfEntry | 1.3.6.1.4.1.9.9.826.1.26.69.1 | not-accessible | Entry for the cfprFabricIfTable table. | |
| CFP cfprFabricIfInstanceId | 1.3.6.1.4.1.9.9.826.1.26.69.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricIfDn | 1.3.6.1.4.1.9.9.826.1.26.69.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:If:dn managed object property |
| STR cfprFabricIfRn | 1.3.6.1.4.1.9.9.826.1.26.69.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:If:rn managed object property |
| ADR cfprFabricIfAddr | 1.3.6.1.4.1.9.9.826.1.26.69.1.4 | InetAddressIPv4 | read-only | Cisco Firepower fabric:If:addr managed object property |
| CFP cfprFabricIfId | 1.3.6.1.4.1.9.9.826.1.26.69.1.5 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:If:id managed object property |
| cfprFabricLacpPolicyTable | 1.3.6.1.4.1.9.9.826.1.26.70 | not-accessible | Cisco Firepower fabric:LacpPolicy managed object table | |
| cfprFabricLacpPolicyEntry | 1.3.6.1.4.1.9.9.826.1.26.70.1 | not-accessible | Entry for the cfprFabricLacpPolicyTable table. | |
| CFP cfprFabricLacpPolicyInstanceId | 1.3.6.1.4.1.9.9.826.1.26.70.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricLacpPolicyDn | 1.3.6.1.4.1.9.9.826.1.26.70.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:LacpPolicy:dn managed object property |
| STR cfprFabricLacpPolicyRn | 1.3.6.1.4.1.9.9.826.1.26.70.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:LacpPolicy:rn managed object property |
| STR cfprFabricLacpPolicyDescr | 1.3.6.1.4.1.9.9.826.1.26.70.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:LacpPolicy:descr managed object property |
| CFP cfprFabricLacpPolicyFastTimer | 1.3.6.1.4.1.9.9.826.1.26.70.1.5 | CfprFabricLacpRate | read-only | Cisco Firepower fabric:LacpPolicy:fastTimer managed object property |
| STR cfprFabricLacpPolicyIntId | 1.3.6.1.4.1.9.9.826.1.26.70.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:LacpPolicy:intId managed object property |
| STR cfprFabricLacpPolicyName | 1.3.6.1.4.1.9.9.826.1.26.70.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:LacpPolicy:name managed object property |
| G32 cfprFabricLacpPolicyPolicyLevel | 1.3.6.1.4.1.9.9.826.1.26.70.1.8 | Gauge32 | read-only | Cisco Firepower fabric:LacpPolicy:policyLevel managed object property |
| CFP cfprFabricLacpPolicyPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.70.1.9 | CfprPolicyPolicyOwner | read-only | Cisco Firepower fabric:LacpPolicy:policyOwner managed object property |
| CFP cfprFabricLacpPolicySuspendIndividual | 1.3.6.1.4.1.9.9.826.1.26.70.1.10 | CfprFabricLacpSuspend | read-only | Cisco Firepower fabric:LacpPolicy:suspendIndividual managed object property |
| cfprFabricLanAccessMgrTable | 1.3.6.1.4.1.9.9.826.1.26.71 | not-accessible | Cisco Firepower fabric:LanAccessMgr managed object table | |
| cfprFabricLanAccessMgrEntry | 1.3.6.1.4.1.9.9.826.1.26.71.1 | not-accessible | Entry for the cfprFabricLanAccessMgrTable table. | |
| CFP cfprFabricLanAccessMgrInstanceId | 1.3.6.1.4.1.9.9.826.1.26.71.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricLanAccessMgrDn | 1.3.6.1.4.1.9.9.826.1.26.71.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:LanAccessMgr:dn managed object property |
| STR cfprFabricLanAccessMgrRn | 1.3.6.1.4.1.9.9.826.1.26.71.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:LanAccessMgr:rn managed object property |
| cfprFabricLanCloudTable | 1.3.6.1.4.1.9.9.826.1.26.72 | not-accessible | Cisco Firepower fabric:LanCloud managed object table | |
| cfprFabricLanCloudEntry | 1.3.6.1.4.1.9.9.826.1.26.72.1 | not-accessible | Entry for the cfprFabricLanCloudTable table. | |
| CFP cfprFabricLanCloudInstanceId | 1.3.6.1.4.1.9.9.826.1.26.72.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricLanCloudDn | 1.3.6.1.4.1.9.9.826.1.26.72.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:LanCloud:dn managed object property |
| STR cfprFabricLanCloudRn | 1.3.6.1.4.1.9.9.826.1.26.72.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:LanCloud:rn managed object property |
| STR cfprFabricLanCloudFsmDescr | 1.3.6.1.4.1.9.9.826.1.26.72.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:LanCloud:fsmDescr managed object property |
| STR cfprFabricLanCloudFsmPrev | 1.3.6.1.4.1.9.9.826.1.26.72.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:LanCloud:fsmPrev managed object property |
| G32 cfprFabricLanCloudFsmProgr | 1.3.6.1.4.1.9.9.826.1.26.72.1.6 | Gauge32 | read-only | Cisco Firepower fabric:LanCloud:fsmProgr managed object property |
| G32 cfprFabricLanCloudFsmRmtInvErrCode | 1.3.6.1.4.1.9.9.826.1.26.72.1.7 | Gauge32 | read-only | Cisco Firepower fabric:LanCloud:fsmRmtInvErrCode managed object property |
| STR cfprFabricLanCloudFsmRmtInvErrDescr | 1.3.6.1.4.1.9.9.826.1.26.72.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:LanCloud:fsmRmtInvErrDescr managed object property |
| CFP cfprFabricLanCloudFsmRmtInvRslt | 1.3.6.1.4.1.9.9.826.1.26.72.1.9 | CfprConditionRemoteInvRslt | read-only | Cisco Firepower fabric:LanCloud:fsmRmtInvRslt managed object property |
| STR cfprFabricLanCloudFsmStageDescr | 1.3.6.1.4.1.9.9.826.1.26.72.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:LanCloud:fsmStageDescr managed object property |
| DAT cfprFabricLanCloudFsmStamp | 1.3.6.1.4.1.9.9.826.1.26.72.1.11 | DateAndTime | read-only | Cisco Firepower fabric:LanCloud:fsmStamp managed object property |
| STR cfprFabricLanCloudFsmStatus | 1.3.6.1.4.1.9.9.826.1.26.72.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:LanCloud:fsmStatus managed object property |
| G32 cfprFabricLanCloudFsmTry | 1.3.6.1.4.1.9.9.826.1.26.72.1.13 | Gauge32 | read-only | Cisco Firepower fabric:LanCloud:fsmTry managed object property |
| NUM cfprFabricLanCloudMacAging | 1.3.6.1.4.1.9.9.826.1.26.72.1.14 | TimeIntervalSec | read-only | Cisco Firepower fabric:LanCloud:macAging managed object property |
| CFP cfprFabricLanCloudMode | 1.3.6.1.4.1.9.9.826.1.26.72.1.15 | CfprFabricSwitchingMode | read-only | Cisco Firepower fabric:LanCloud:mode managed object property |
| CFP cfprFabricLanCloudVlanCompression | 1.3.6.1.4.1.9.9.826.1.26.72.1.16 | CfprFabricLanCloudVlanCompression | read-only | Cisco Firepower fabric:LanCloud:vlanCompression managed object property |
| cfprFabricLanCloudFsmTable | 1.3.6.1.4.1.9.9.826.1.26.73 | not-accessible | Cisco Firepower fabric:LanCloudFsm managed object table | |
| cfprFabricLanCloudFsmEntry | 1.3.6.1.4.1.9.9.826.1.26.73.1 | not-accessible | Entry for the cfprFabricLanCloudFsmTable table. | |
| CFP cfprFabricLanCloudFsmInstanceId | 1.3.6.1.4.1.9.9.826.1.26.73.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricLanCloudFsmDn | 1.3.6.1.4.1.9.9.826.1.26.73.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:LanCloudFsm:dn managed object property |
| STR cfprFabricLanCloudFsmRn | 1.3.6.1.4.1.9.9.826.1.26.73.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:LanCloudFsm:rn managed object property |
| DAT cfprFabricLanCloudFsmCompletionTime | 1.3.6.1.4.1.9.9.826.1.26.73.1.4 | DateAndTime | read-only | Cisco Firepower fabric:LanCloudFsm:completionTime managed object property |
| CFP cfprFabricLanCloudFsmCurrentFsm | 1.3.6.1.4.1.9.9.826.1.26.73.1.5 | CfprFabricLanCloudFsmCurrentFsm | read-only | Cisco Firepower fabric:LanCloudFsm:currentFsm managed object property |
| STR cfprFabricLanCloudFsmDescrData | 1.3.6.1.4.1.9.9.826.1.26.73.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:LanCloudFsm:descr managed object property |
| CFP cfprFabricLanCloudFsmFsmStatus | 1.3.6.1.4.1.9.9.826.1.26.73.1.7 | CfprFsmFsmStageStatus | read-only | Cisco Firepower fabric:LanCloudFsm:fsmStatus managed object property |
| G32 cfprFabricLanCloudFsmProgress | 1.3.6.1.4.1.9.9.826.1.26.73.1.8 | Gauge32 | read-only | Cisco Firepower fabric:LanCloudFsm:progress managed object property |
| G32 cfprFabricLanCloudFsmRmtErrCode | 1.3.6.1.4.1.9.9.826.1.26.73.1.9 | Gauge32 | read-only | Cisco Firepower fabric:LanCloudFsm:rmtErrCode managed object property |
| STR cfprFabricLanCloudFsmRmtErrDescr | 1.3.6.1.4.1.9.9.826.1.26.73.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:LanCloudFsm:rmtErrDescr managed object property |
| CFP cfprFabricLanCloudFsmRmtRslt | 1.3.6.1.4.1.9.9.826.1.26.73.1.11 | CfprConditionRemoteInvRslt | read-only | Cisco Firepower fabric:LanCloudFsm:rmtRslt managed object property |
| cfprFabricLanCloudFsmStageTable | 1.3.6.1.4.1.9.9.826.1.26.74 | not-accessible | Cisco Firepower fabric:LanCloudFsmStage managed object table | |
| cfprFabricLanCloudFsmStageEntry | 1.3.6.1.4.1.9.9.826.1.26.74.1 | not-accessible | Entry for the cfprFabricLanCloudFsmStageTable table. | |
| CFP cfprFabricLanCloudFsmStageInstanceId | 1.3.6.1.4.1.9.9.826.1.26.74.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricLanCloudFsmStageDn | 1.3.6.1.4.1.9.9.826.1.26.74.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:LanCloudFsmStage:dn managed object property |
| STR cfprFabricLanCloudFsmStageRn | 1.3.6.1.4.1.9.9.826.1.26.74.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:LanCloudFsmStage:rn managed object property |
| STR cfprFabricLanCloudFsmStageDescrData | 1.3.6.1.4.1.9.9.826.1.26.74.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:LanCloudFsmStage:descr managed object property |
| DAT cfprFabricLanCloudFsmStageLastUpdateTime | 1.3.6.1.4.1.9.9.826.1.26.74.1.5 | DateAndTime | read-only | Cisco Firepower fabric:LanCloudFsmStage:lastUpdateTime managed object property |
| CFP cfprFabricLanCloudFsmStageName | 1.3.6.1.4.1.9.9.826.1.26.74.1.6 | CfprFabricLanCloudFsmStageName | read-only | Cisco Firepower fabric:LanCloudFsmStage:name managed object property |
| G32 cfprFabricLanCloudFsmStageOrder | 1.3.6.1.4.1.9.9.826.1.26.74.1.7 | Gauge32 | read-only | Cisco Firepower fabric:LanCloudFsmStage:order managed object property |
| G32 cfprFabricLanCloudFsmStageRetry | 1.3.6.1.4.1.9.9.826.1.26.74.1.8 | Gauge32 | read-only | Cisco Firepower fabric:LanCloudFsmStage:retry managed object property |
| CFP cfprFabricLanCloudFsmStageStageStatus | 1.3.6.1.4.1.9.9.826.1.26.74.1.9 | CfprFsmFsmStageStatus | read-only | Cisco Firepower fabric:LanCloudFsmStage:stageStatus managed object property |
| cfprFabricLanCloudFsmTaskTable | 1.3.6.1.4.1.9.9.826.1.26.75 | not-accessible | Cisco Firepower fabric:LanCloudFsmTask managed object table | |
| cfprFabricLanCloudFsmTaskEntry | 1.3.6.1.4.1.9.9.826.1.26.75.1 | not-accessible | Entry for the cfprFabricLanCloudFsmTaskTable table. | |
| CFP cfprFabricLanCloudFsmTaskInstanceId | 1.3.6.1.4.1.9.9.826.1.26.75.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricLanCloudFsmTaskDn | 1.3.6.1.4.1.9.9.826.1.26.75.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:LanCloudFsmTask:dn managed object property |
| STR cfprFabricLanCloudFsmTaskRn | 1.3.6.1.4.1.9.9.826.1.26.75.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:LanCloudFsmTask:rn managed object property |
| CFP cfprFabricLanCloudFsmTaskCompletion | 1.3.6.1.4.1.9.9.826.1.26.75.1.4 | CfprFsmCompletion | read-only | Cisco Firepower fabric:LanCloudFsmTask:completion managed object property |
| CFP cfprFabricLanCloudFsmTaskFlags | 1.3.6.1.4.1.9.9.826.1.26.75.1.5 | CfprFsmFlags | read-only | Cisco Firepower fabric:LanCloudFsmTask:flags managed object property |
| CFP cfprFabricLanCloudFsmTaskItem | 1.3.6.1.4.1.9.9.826.1.26.75.1.6 | CfprFabricLanCloudFsmTaskItem | read-only | Cisco Firepower fabric:LanCloudFsmTask:item managed object property |
| G32 cfprFabricLanCloudFsmTaskSeqId | 1.3.6.1.4.1.9.9.826.1.26.75.1.7 | Gauge32 | read-only | Cisco Firepower fabric:LanCloudFsmTask:seqId managed object property |
| cfprFabricLanMonCloudTable | 1.3.6.1.4.1.9.9.826.1.26.76 | not-accessible | Cisco Firepower fabric:LanMonCloud managed object table | |
| cfprFabricLanMonCloudEntry | 1.3.6.1.4.1.9.9.826.1.26.76.1 | not-accessible | Entry for the cfprFabricLanMonCloudTable table. | |
| CFP cfprFabricLanMonCloudInstanceId | 1.3.6.1.4.1.9.9.826.1.26.76.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricLanMonCloudDn | 1.3.6.1.4.1.9.9.826.1.26.76.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:LanMonCloud:dn managed object property |
| STR cfprFabricLanMonCloudRn | 1.3.6.1.4.1.9.9.826.1.26.76.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:LanMonCloud:rn managed object property |
| CFP cfprFabricLanMonCloudMode | 1.3.6.1.4.1.9.9.826.1.26.76.1.4 | CfprFabricSwitchingMode | read-only | Cisco Firepower fabric:LanMonCloud:mode managed object property |
| cfprFabricLanPinGroupTable | 1.3.6.1.4.1.9.9.826.1.26.77 | not-accessible | Cisco Firepower fabric:LanPinGroup managed object table | |
| cfprFabricLanPinGroupEntry | 1.3.6.1.4.1.9.9.826.1.26.77.1 | not-accessible | Entry for the cfprFabricLanPinGroupTable table. | |
| CFP cfprFabricLanPinGroupInstanceId | 1.3.6.1.4.1.9.9.826.1.26.77.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricLanPinGroupDn | 1.3.6.1.4.1.9.9.826.1.26.77.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:LanPinGroup:dn managed object property |
| STR cfprFabricLanPinGroupRn | 1.3.6.1.4.1.9.9.826.1.26.77.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:LanPinGroup:rn managed object property |
| STR cfprFabricLanPinGroupDescr | 1.3.6.1.4.1.9.9.826.1.26.77.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:LanPinGroup:descr managed object property |
| STR cfprFabricLanPinGroupIntId | 1.3.6.1.4.1.9.9.826.1.26.77.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:LanPinGroup:intId managed object property |
| STR cfprFabricLanPinGroupName | 1.3.6.1.4.1.9.9.826.1.26.77.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:LanPinGroup:name managed object property |
| G32 cfprFabricLanPinGroupPolicyLevel | 1.3.6.1.4.1.9.9.826.1.26.77.1.7 | Gauge32 | read-only | Cisco Firepower fabric:LanPinGroup:policyLevel managed object property |
| CFP cfprFabricLanPinGroupPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.77.1.8 | CfprPolicyPolicyOwner | read-only | Cisco Firepower fabric:LanPinGroup:policyOwner managed object property |
| G32 cfprFabricLanPinGroupSize | 1.3.6.1.4.1.9.9.826.1.26.77.1.9 | Gauge32 | read-only | Cisco Firepower fabric:LanPinGroup:size managed object property |
| cfprFabricLanPinTargetTable | 1.3.6.1.4.1.9.9.826.1.26.78 | not-accessible | Cisco Firepower fabric:LanPinTarget managed object table | |
| cfprFabricLanPinTargetEntry | 1.3.6.1.4.1.9.9.826.1.26.78.1 | not-accessible | Entry for the cfprFabricLanPinTargetTable table. | |
| CFP cfprFabricLanPinTargetInstanceId | 1.3.6.1.4.1.9.9.826.1.26.78.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricLanPinTargetDn | 1.3.6.1.4.1.9.9.826.1.26.78.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:LanPinTarget:dn managed object property |
| STR cfprFabricLanPinTargetRn | 1.3.6.1.4.1.9.9.826.1.26.78.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:LanPinTarget:rn managed object property |
| STR cfprFabricLanPinTargetEpDn | 1.3.6.1.4.1.9.9.826.1.26.78.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:LanPinTarget:epDn managed object property |
| STR cfprFabricLanPinTargetFabricId | 1.3.6.1.4.1.9.9.826.1.26.78.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:LanPinTarget:fabricId managed object property |
| CFP cfprFabricLanPinTargetTargetStatus | 1.3.6.1.4.1.9.9.826.1.26.78.1.6 | CfprFabricTargetStatus | read-only | Cisco Firepower fabric:LanPinTarget:targetStatus managed object property |
| cfprFabricLastAckedSlotTable | 1.3.6.1.4.1.9.9.826.1.26.79 | not-accessible | Cisco Firepower fabric:LastAckedSlot managed object table | |
| cfprFabricLastAckedSlotEntry | 1.3.6.1.4.1.9.9.826.1.26.79.1 | not-accessible | Entry for the cfprFabricLastAckedSlotTable table. | |
| CFP cfprFabricLastAckedSlotInstanceId | 1.3.6.1.4.1.9.9.826.1.26.79.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricLastAckedSlotDn | 1.3.6.1.4.1.9.9.826.1.26.79.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:LastAckedSlot:dn managed object property |
| STR cfprFabricLastAckedSlotRn | 1.3.6.1.4.1.9.9.826.1.26.79.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:LastAckedSlot:rn managed object property |
| CFP cfprFabricLastAckedSlotBoardAggregationRole | 1.3.6.1.4.1.9.9.826.1.26.79.1.4 | CfprEquipmentBoardAggregationRole | read-only | Cisco Firepower fabric:LastAckedSlot:boardAggregationRole managed object property |
| G32 cfprFabricLastAckedSlotChassisId | 1.3.6.1.4.1.9.9.826.1.26.79.1.5 | Gauge32 | read-only | Cisco Firepower fabric:LastAckedSlot:chassisId managed object property |
| G32 cfprFabricLastAckedSlotSlotId | 1.3.6.1.4.1.9.9.826.1.26.79.1.6 | Gauge32 | read-only | Cisco Firepower fabric:LastAckedSlot:slotId managed object property |
| CFP cfprFabricLastAckedSlotSwitchId | 1.3.6.1.4.1.9.9.826.1.26.79.1.7 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:LastAckedSlot:switchId managed object property |
| cfprFabricLocaleTable | 1.3.6.1.4.1.9.9.826.1.26.80 | not-accessible | Cisco Firepower fabric:Locale managed object table | |
| cfprFabricLocaleEntry | 1.3.6.1.4.1.9.9.826.1.26.80.1 | not-accessible | Entry for the cfprFabricLocaleTable table. | |
| CFP cfprFabricLocaleInstanceId | 1.3.6.1.4.1.9.9.826.1.26.80.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricLocaleDn | 1.3.6.1.4.1.9.9.826.1.26.80.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:Locale:dn managed object property |
| STR cfprFabricLocaleRn | 1.3.6.1.4.1.9.9.826.1.26.80.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:Locale:rn managed object property |
| G32 cfprFabricLocaleCType | 1.3.6.1.4.1.9.9.826.1.26.80.1.4 | Gauge32 | read-only | Cisco Firepower fabric:Locale:cType managed object property |
| G32 cfprFabricLocaleChassisId | 1.3.6.1.4.1.9.9.826.1.26.80.1.5 | Gauge32 | read-only | Cisco Firepower fabric:Locale:chassisId managed object property |
| CFP cfprFabricLocaleLocale | 1.3.6.1.4.1.9.9.826.1.26.80.1.6 | CfprNetworkLocale | read-only | Cisco Firepower fabric:Locale:locale managed object property |
| STR cfprFabricLocaleName | 1.3.6.1.4.1.9.9.826.1.26.80.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:Locale:name managed object property |
| CFP cfprFabricLocaleSide | 1.3.6.1.4.1.9.9.826.1.26.80.1.8 | CfprNetworkSide | read-only | Cisco Firepower fabric:Locale:side managed object property |
| G32 cfprFabricLocaleSlotId | 1.3.6.1.4.1.9.9.826.1.26.80.1.9 | Gauge32 | read-only | Cisco Firepower fabric:Locale:slotId managed object property |
| CFP cfprFabricLocaleSwitchId | 1.3.6.1.4.1.9.9.826.1.26.80.1.10 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:Locale:switchId managed object property |
| CFP cfprFabricLocaleTransport | 1.3.6.1.4.1.9.9.826.1.26.80.1.11 | CfprNetworkTransport | read-only | Cisco Firepower fabric:Locale:transport managed object property |
| CFP cfprFabricLocaleType | 1.3.6.1.4.1.9.9.826.1.26.80.1.12 | CfprNetworkConnectionType | read-only | Cisco Firepower fabric:Locale:type managed object property |
| cfprFabricMulticastPolicyTable | 1.3.6.1.4.1.9.9.826.1.26.81 | not-accessible | Cisco Firepower fabric:MulticastPolicy managed object table | |
| cfprFabricMulticastPolicyEntry | 1.3.6.1.4.1.9.9.826.1.26.81.1 | not-accessible | Entry for the cfprFabricMulticastPolicyTable table. | |
| CFP cfprFabricMulticastPolicyInstanceId | 1.3.6.1.4.1.9.9.826.1.26.81.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricMulticastPolicyDn | 1.3.6.1.4.1.9.9.826.1.26.81.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:MulticastPolicy:dn managed object property |
| STR cfprFabricMulticastPolicyRn | 1.3.6.1.4.1.9.9.826.1.26.81.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:MulticastPolicy:rn managed object property |
| STR cfprFabricMulticastPolicyDescr | 1.3.6.1.4.1.9.9.826.1.26.81.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:MulticastPolicy:descr managed object property |
| STR cfprFabricMulticastPolicyIntId | 1.3.6.1.4.1.9.9.826.1.26.81.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:MulticastPolicy:intId managed object property |
| STR cfprFabricMulticastPolicyName | 1.3.6.1.4.1.9.9.826.1.26.81.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:MulticastPolicy:name managed object property |
| G32 cfprFabricMulticastPolicyPolicyLevel | 1.3.6.1.4.1.9.9.826.1.26.81.1.7 | Gauge32 | read-only | Cisco Firepower fabric:MulticastPolicy:policyLevel managed object property |
| CFP cfprFabricMulticastPolicyPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.81.1.8 | CfprPolicyPolicyOwner | read-only | Cisco Firepower fabric:MulticastPolicy:policyOwner managed object property |
| ADR cfprFabricMulticastPolicyQuerierIpAddr | 1.3.6.1.4.1.9.9.826.1.26.81.1.9 | InetAddressIPv4 | read-only | Cisco Firepower fabric:MulticastPolicy:querierIpAddr managed object property |
| CFP cfprFabricMulticastPolicyQuerierState | 1.3.6.1.4.1.9.9.826.1.26.81.1.10 | CfprFabricQuerierType | read-only | Cisco Firepower fabric:MulticastPolicy:querierState managed object property |
| CFP cfprFabricMulticastPolicySnoopingState | 1.3.6.1.4.1.9.9.826.1.26.81.1.11 | CfprFabricSnoopingType | read-only | Cisco Firepower fabric:MulticastPolicy:snoopingState managed object property |
| cfprFabricNetGroupTable | 1.3.6.1.4.1.9.9.826.1.26.82 | not-accessible | Cisco Firepower fabric:NetGroup managed object table | |
| cfprFabricNetGroupEntry | 1.3.6.1.4.1.9.9.826.1.26.82.1 | not-accessible | Entry for the cfprFabricNetGroupTable table. | |
| CFP cfprFabricNetGroupInstanceId | 1.3.6.1.4.1.9.9.826.1.26.82.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricNetGroupDn | 1.3.6.1.4.1.9.9.826.1.26.82.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:NetGroup:dn managed object property |
| STR cfprFabricNetGroupRn | 1.3.6.1.4.1.9.9.826.1.26.82.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:NetGroup:rn managed object property |
| G32 cfprFabricNetGroupAssigned | 1.3.6.1.4.1.9.9.826.1.26.82.1.4 | Gauge32 | read-only | Cisco Firepower fabric:NetGroup:assigned managed object property |
| CFP cfprFabricNetGroupAssignmentOrder | 1.3.6.1.4.1.9.9.826.1.26.82.1.5 | CfprPoolPoolAssignmentOrder | read-only | Cisco Firepower fabric:NetGroup:assignmentOrder managed object property |
| STR cfprFabricNetGroupDescr | 1.3.6.1.4.1.9.9.826.1.26.82.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:NetGroup:descr managed object property |
| G32 cfprFabricNetGroupId | 1.3.6.1.4.1.9.9.826.1.26.82.1.7 | Gauge32 | read-only | Cisco Firepower fabric:NetGroup:id managed object property |
| STR cfprFabricNetGroupIntId | 1.3.6.1.4.1.9.9.826.1.26.82.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:NetGroup:intId managed object property |
| STR cfprFabricNetGroupName | 1.3.6.1.4.1.9.9.826.1.26.82.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:NetGroup:name managed object property |
| STR cfprFabricNetGroupNativeNet | 1.3.6.1.4.1.9.9.826.1.26.82.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:NetGroup:nativeNet managed object property |
| STR cfprFabricNetGroupNativeNetDn | 1.3.6.1.4.1.9.9.826.1.26.82.1.11 | SnmpAdminString | read-only | Cisco Firepower fabric:NetGroup:nativeNetDn managed object property |
| CFP cfprFabricNetGroupOwner | 1.3.6.1.4.1.9.9.826.1.26.82.1.12 | CfprFabricOwner | read-only | Cisco Firepower fabric:NetGroup:owner managed object property |
| STR cfprFabricNetGroupPeerDn | 1.3.6.1.4.1.9.9.826.1.26.82.1.13 | SnmpAdminString | read-only | Cisco Firepower fabric:NetGroup:peerDn managed object property |
| G32 cfprFabricNetGroupPolicyLevel | 1.3.6.1.4.1.9.9.826.1.26.82.1.14 | Gauge32 | read-only | Cisco Firepower fabric:NetGroup:policyLevel managed object property |
| CFP cfprFabricNetGroupPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.82.1.15 | CfprPolicyPolicyOwner | read-only | Cisco Firepower fabric:NetGroup:policyOwner managed object property |
| G32 cfprFabricNetGroupSize | 1.3.6.1.4.1.9.9.826.1.26.82.1.16 | Gauge32 | read-only | Cisco Firepower fabric:NetGroup:size managed object property |
| CFP cfprFabricNetGroupSwitchId | 1.3.6.1.4.1.9.9.826.1.26.82.1.17 | CfprFabricNetGroupSwitchId | read-only | Cisco Firepower fabric:NetGroup:switchId managed object property |
| CFP cfprFabricNetGroupType | 1.3.6.1.4.1.9.9.826.1.26.82.1.18 | CfprFabricNetGroupType | read-only | Cisco Firepower fabric:NetGroup:type managed object property |
| cfprFabricOrgVlanPolicyTable | 1.3.6.1.4.1.9.9.826.1.26.93 | not-accessible | Cisco Firepower fabric:OrgVlanPolicy managed object table | |
| cfprFabricOrgVlanPolicyEntry | 1.3.6.1.4.1.9.9.826.1.26.93.1 | not-accessible | Entry for the cfprFabricOrgVlanPolicyTable table. | |
| CFP cfprFabricOrgVlanPolicyInstanceId | 1.3.6.1.4.1.9.9.826.1.26.93.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricOrgVlanPolicyDn | 1.3.6.1.4.1.9.9.826.1.26.93.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:OrgVlanPolicy:dn managed object property |
| STR cfprFabricOrgVlanPolicyRn | 1.3.6.1.4.1.9.9.826.1.26.93.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:OrgVlanPolicy:rn managed object property |
| CFP cfprFabricOrgVlanPolicyAdminState | 1.3.6.1.4.1.9.9.826.1.26.93.1.4 | CfprFabricAdminState | read-only | Cisco Firepower fabric:OrgVlanPolicy:adminState managed object property |
| STR cfprFabricOrgVlanPolicyName | 1.3.6.1.4.1.9.9.826.1.26.93.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:OrgVlanPolicy:name managed object property |
| cfprFabricPathTable | 1.3.6.1.4.1.9.9.826.1.26.94 | not-accessible | Cisco Firepower fabric:Path managed object table | |
| cfprFabricPathEntry | 1.3.6.1.4.1.9.9.826.1.26.94.1 | not-accessible | Entry for the cfprFabricPathTable table. | |
| CFP cfprFabricPathInstanceId | 1.3.6.1.4.1.9.9.826.1.26.94.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricPathDn | 1.3.6.1.4.1.9.9.826.1.26.94.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:Path:dn managed object property |
| STR cfprFabricPathRn | 1.3.6.1.4.1.9.9.826.1.26.94.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:Path:rn managed object property |
| G32 cfprFabricPathCType | 1.3.6.1.4.1.9.9.826.1.26.94.1.4 | Gauge32 | read-only | Cisco Firepower fabric:Path:cType managed object property |
| G32 cfprFabricPathChassisId | 1.3.6.1.4.1.9.9.826.1.26.94.1.5 | Gauge32 | read-only | Cisco Firepower fabric:Path:chassisId managed object property |
| G32 cfprFabricPathEnacp | 1.3.6.1.4.1.9.9.826.1.26.94.1.6 | Gauge32 | read-only | Cisco Firepower fabric:Path:enacp managed object property |
| G32 cfprFabricPathId | 1.3.6.1.4.1.9.9.826.1.26.94.1.7 | Gauge32 | read-only | Cisco Firepower fabric:Path:id managed object property |
| CFP cfprFabricPathLocale | 1.3.6.1.4.1.9.9.826.1.26.94.1.8 | CfprNetworkLocale | read-only | Cisco Firepower fabric:Path:locale managed object property |
| STR cfprFabricPathName | 1.3.6.1.4.1.9.9.826.1.26.94.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:Path:name managed object property |
| G32 cfprFabricPathNsSize | 1.3.6.1.4.1.9.9.826.1.26.94.1.10 | Gauge32 | read-only | Cisco Firepower fabric:Path:nsSize managed object property |
| CFP cfprFabricPathSide | 1.3.6.1.4.1.9.9.826.1.26.94.1.11 | CfprNetworkSide | read-only | Cisco Firepower fabric:Path:side managed object property |
| CFP cfprFabricPathSwitchId | 1.3.6.1.4.1.9.9.826.1.26.94.1.12 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:Path:switchId managed object property |
| CFP cfprFabricPathTransport | 1.3.6.1.4.1.9.9.826.1.26.94.1.13 | CfprNetworkTransport | read-only | Cisco Firepower fabric:Path:transport managed object property |
| CFP cfprFabricPathType | 1.3.6.1.4.1.9.9.826.1.26.94.1.14 | CfprNetworkConnectionType | read-only | Cisco Firepower fabric:Path:type managed object property |
| cfprFabricPathConnTable | 1.3.6.1.4.1.9.9.826.1.26.95 | not-accessible | Cisco Firepower fabric:PathConn managed object table | |
| cfprFabricPathConnEntry | 1.3.6.1.4.1.9.9.826.1.26.95.1 | not-accessible | Entry for the cfprFabricPathConnTable table. | |
| CFP cfprFabricPathConnInstanceId | 1.3.6.1.4.1.9.9.826.1.26.95.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricPathConnDn | 1.3.6.1.4.1.9.9.826.1.26.95.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:PathConn:dn managed object property |
| STR cfprFabricPathConnRn | 1.3.6.1.4.1.9.9.826.1.26.95.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:PathConn:rn managed object property |
| G32 cfprFabricPathConnCType | 1.3.6.1.4.1.9.9.826.1.26.95.1.4 | Gauge32 | read-only | Cisco Firepower fabric:PathConn:cType managed object property |
| CFP cfprFabricPathConnLocale | 1.3.6.1.4.1.9.9.826.1.26.95.1.5 | CfprNetworkLocale | read-only | Cisco Firepower fabric:PathConn:locale managed object property |
| STR cfprFabricPathConnName | 1.3.6.1.4.1.9.9.826.1.26.95.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:PathConn:name managed object property |
| CFP cfprFabricPathConnTransport | 1.3.6.1.4.1.9.9.826.1.26.95.1.7 | CfprNetworkTransport | read-only | Cisco Firepower fabric:PathConn:transport managed object property |
| CFP cfprFabricPathConnType | 1.3.6.1.4.1.9.9.826.1.26.95.1.8 | CfprNetworkConnectionType | read-only | Cisco Firepower fabric:PathConn:type managed object property |
| cfprFabricPathEpTable | 1.3.6.1.4.1.9.9.826.1.26.96 | not-accessible | Cisco Firepower fabric:PathEp managed object table | |
| cfprFabricPathEpEntry | 1.3.6.1.4.1.9.9.826.1.26.96.1 | not-accessible | Entry for the cfprFabricPathEpTable table. | |
| CFP cfprFabricPathEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.96.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricPathEpDn | 1.3.6.1.4.1.9.9.826.1.26.96.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:PathEp:dn managed object property |
| STR cfprFabricPathEpRn | 1.3.6.1.4.1.9.9.826.1.26.96.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:PathEp:rn managed object property |
| G32 cfprFabricPathEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.96.1.4 | Gauge32 | read-only | Cisco Firepower fabric:PathEp:aggrPortId managed object property |
| G32 cfprFabricPathEpCType | 1.3.6.1.4.1.9.9.826.1.26.96.1.5 | Gauge32 | read-only | Cisco Firepower fabric:PathEp:cType managed object property |
| G32 cfprFabricPathEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.96.1.6 | Gauge32 | read-only | Cisco Firepower fabric:PathEp:chassisId managed object property |
| T/F cfprFabricPathEpDiagLldpTransmit | 1.3.6.1.4.1.9.9.826.1.26.96.1.7 | TruthValue | read-only | Cisco Firepower fabric:PathEp:diagLldpTransmit managed object property |
| STR cfprFabricPathEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.96.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:PathEp:epDn managed object property |
| CFP cfprFabricPathEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.96.1.9 | CfprNetworkPortRole | read-only | Cisco Firepower fabric:PathEp:ifRole managed object property |
| CFP cfprFabricPathEpIfType | 1.3.6.1.4.1.9.9.826.1.26.96.1.10 | CfprFabricPathEpIfType | read-only | Cisco Firepower fabric:PathEp:ifType managed object property |
| CFP cfprFabricPathEpLocale | 1.3.6.1.4.1.9.9.826.1.26.96.1.11 | CfprFabricPathEpLocale | read-only | Cisco Firepower fabric:PathEp:locale managed object property |
| STR cfprFabricPathEpName | 1.3.6.1.4.1.9.9.826.1.26.96.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:PathEp:name managed object property |
| G32 cfprFabricPathEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.96.1.13 | Gauge32 | read-only | Cisco Firepower fabric:PathEp:peerAggrPortId managed object property |
| G32 cfprFabricPathEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.96.1.14 | Gauge32 | read-only | Cisco Firepower fabric:PathEp:peerChassisId managed object property |
| STR cfprFabricPathEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.96.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:PathEp:peerDn managed object property |
| MAC cfprFabricPathEpPeerMac | 1.3.6.1.4.1.9.9.826.1.26.96.1.16 | MacAddress | read-only | Cisco Firepower fabric:PathEp:peerMac managed object property |
| G32 cfprFabricPathEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.96.1.17 | Gauge32 | read-only | Cisco Firepower fabric:PathEp:peerPortId managed object property |
| G32 cfprFabricPathEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.96.1.18 | Gauge32 | read-only | Cisco Firepower fabric:PathEp:peerSlotId managed object property |
| G32 cfprFabricPathEpPortId | 1.3.6.1.4.1.9.9.826.1.26.96.1.19 | Gauge32 | read-only | Cisco Firepower fabric:PathEp:portId managed object property |
| CFP cfprFabricPathEpSide | 1.3.6.1.4.1.9.9.826.1.26.96.1.20 | CfprNetworkSide | read-only | Cisco Firepower fabric:PathEp:side managed object property |
| G32 cfprFabricPathEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.96.1.21 | Gauge32 | read-only | Cisco Firepower fabric:PathEp:slotId managed object property |
| CFP cfprFabricPathEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.96.1.22 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:PathEp:switchId managed object property |
| CFP cfprFabricPathEpTransport | 1.3.6.1.4.1.9.9.826.1.26.96.1.23 | CfprNetworkTransport | read-only | Cisco Firepower fabric:PathEp:transport managed object property |
| CFP cfprFabricPathEpType | 1.3.6.1.4.1.9.9.826.1.26.96.1.24 | CfprNetworkConnectionType | read-only | Cisco Firepower fabric:PathEp:type managed object property |
| cfprFabricPoolableVlanTable | 1.3.6.1.4.1.9.9.826.1.26.97 | not-accessible | Cisco Firepower fabric:PoolableVlan managed object table | |
| cfprFabricPoolableVlanEntry | 1.3.6.1.4.1.9.9.826.1.26.97.1 | not-accessible | Entry for the cfprFabricPoolableVlanTable table. | |
| CFP cfprFabricPoolableVlanInstanceId | 1.3.6.1.4.1.9.9.826.1.26.97.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricPoolableVlanDn | 1.3.6.1.4.1.9.9.826.1.26.97.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:PoolableVlan:dn managed object property |
| STR cfprFabricPoolableVlanRn | 1.3.6.1.4.1.9.9.826.1.26.97.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:PoolableVlan:rn managed object property |
| UNS cfprFabricPoolableVlanId | 1.3.6.1.4.1.9.9.826.1.26.97.1.4 | Unsigned64 | read-only | Cisco Firepower fabric:PoolableVlan:id managed object property |
| STR cfprFabricPoolableVlanPoolDn | 1.3.6.1.4.1.9.9.826.1.26.97.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:PoolableVlan:poolDn managed object property |
| cfprFabricPooledVlanTable | 1.3.6.1.4.1.9.9.826.1.26.98 | not-accessible | Cisco Firepower fabric:PooledVlan managed object table | |
| cfprFabricPooledVlanEntry | 1.3.6.1.4.1.9.9.826.1.26.98.1 | not-accessible | Entry for the cfprFabricPooledVlanTable table. | |
| CFP cfprFabricPooledVlanInstanceId | 1.3.6.1.4.1.9.9.826.1.26.98.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricPooledVlanDn | 1.3.6.1.4.1.9.9.826.1.26.98.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:PooledVlan:dn managed object property |
| STR cfprFabricPooledVlanRn | 1.3.6.1.4.1.9.9.826.1.26.98.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:PooledVlan:rn managed object property |
| T/F cfprFabricPooledVlanAssigned | 1.3.6.1.4.1.9.9.826.1.26.98.1.4 | TruthValue | read-only | Cisco Firepower fabric:PooledVlan:assigned managed object property |
| STR cfprFabricPooledVlanAssignedToDn | 1.3.6.1.4.1.9.9.826.1.26.98.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:PooledVlan:assignedToDn managed object property |
| CFP cfprFabricPooledVlanConfigIssues | 1.3.6.1.4.1.9.9.826.1.26.98.1.6 | CfprFabricPoolMemberConfigIssues | read-only | Cisco Firepower fabric:PooledVlan:configIssues managed object property |
| STR cfprFabricPooledVlanName | 1.3.6.1.4.1.9.9.826.1.26.98.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:PooledVlan:name managed object property |
| STR cfprFabricPooledVlanPeerDn | 1.3.6.1.4.1.9.9.826.1.26.98.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:PooledVlan:peerDn managed object property |
| STR cfprFabricPooledVlanPoolableDn | 1.3.6.1.4.1.9.9.826.1.26.98.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:PooledVlan:poolableDn managed object property |
| STR cfprFabricPooledVlanPrevAssignedToDn | 1.3.6.1.4.1.9.9.826.1.26.98.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:PooledVlan:prevAssignedToDn managed object property |
| cfprFabricSanCloudTable | 1.3.6.1.4.1.9.9.826.1.26.99 | not-accessible | Cisco Firepower fabric:SanCloud managed object table | |
| cfprFabricSanCloudEntry | 1.3.6.1.4.1.9.9.826.1.26.99.1 | not-accessible | Entry for the cfprFabricSanCloudTable table. | |
| CFP cfprFabricSanCloudInstanceId | 1.3.6.1.4.1.9.9.826.1.26.99.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSanCloudDn | 1.3.6.1.4.1.9.9.826.1.26.99.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SanCloud:dn managed object property |
| STR cfprFabricSanCloudRn | 1.3.6.1.4.1.9.9.826.1.26.99.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SanCloud:rn managed object property |
| STR cfprFabricSanCloudFsmDescr | 1.3.6.1.4.1.9.9.826.1.26.99.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:SanCloud:fsmDescr managed object property |
| STR cfprFabricSanCloudFsmPrev | 1.3.6.1.4.1.9.9.826.1.26.99.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:SanCloud:fsmPrev managed object property |
| G32 cfprFabricSanCloudFsmProgr | 1.3.6.1.4.1.9.9.826.1.26.99.1.6 | Gauge32 | read-only | Cisco Firepower fabric:SanCloud:fsmProgr managed object property |
| G32 cfprFabricSanCloudFsmRmtInvErrCode | 1.3.6.1.4.1.9.9.826.1.26.99.1.7 | Gauge32 | read-only | Cisco Firepower fabric:SanCloud:fsmRmtInvErrCode managed object property |
| STR cfprFabricSanCloudFsmRmtInvErrDescr | 1.3.6.1.4.1.9.9.826.1.26.99.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:SanCloud:fsmRmtInvErrDescr managed object property |
| CFP cfprFabricSanCloudFsmRmtInvRslt | 1.3.6.1.4.1.9.9.826.1.26.99.1.9 | CfprConditionRemoteInvRslt | read-only | Cisco Firepower fabric:SanCloud:fsmRmtInvRslt managed object property |
| STR cfprFabricSanCloudFsmStageDescr | 1.3.6.1.4.1.9.9.826.1.26.99.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:SanCloud:fsmStageDescr managed object property |
| DAT cfprFabricSanCloudFsmStamp | 1.3.6.1.4.1.9.9.826.1.26.99.1.11 | DateAndTime | read-only | Cisco Firepower fabric:SanCloud:fsmStamp managed object property |
| STR cfprFabricSanCloudFsmStatus | 1.3.6.1.4.1.9.9.826.1.26.99.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:SanCloud:fsmStatus managed object property |
| G32 cfprFabricSanCloudFsmTry | 1.3.6.1.4.1.9.9.826.1.26.99.1.13 | Gauge32 | read-only | Cisco Firepower fabric:SanCloud:fsmTry managed object property |
| CFP cfprFabricSanCloudMode | 1.3.6.1.4.1.9.9.826.1.26.99.1.14 | CfprFabricSwitchingMode | read-only | Cisco Firepower fabric:SanCloud:mode managed object property |
| cfprFabricSanCloudFsmTable | 1.3.6.1.4.1.9.9.826.1.26.100 | not-accessible | Cisco Firepower fabric:SanCloudFsm managed object table | |
| cfprFabricSanCloudFsmEntry | 1.3.6.1.4.1.9.9.826.1.26.100.1 | not-accessible | Entry for the cfprFabricSanCloudFsmTable table. | |
| CFP cfprFabricSanCloudFsmInstanceId | 1.3.6.1.4.1.9.9.826.1.26.100.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSanCloudFsmDn | 1.3.6.1.4.1.9.9.826.1.26.100.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SanCloudFsm:dn managed object property |
| STR cfprFabricSanCloudFsmRn | 1.3.6.1.4.1.9.9.826.1.26.100.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SanCloudFsm:rn managed object property |
| DAT cfprFabricSanCloudFsmCompletionTime | 1.3.6.1.4.1.9.9.826.1.26.100.1.4 | DateAndTime | read-only | Cisco Firepower fabric:SanCloudFsm:completionTime managed object property |
| CFP cfprFabricSanCloudFsmCurrentFsm | 1.3.6.1.4.1.9.9.826.1.26.100.1.5 | CfprFabricSanCloudFsmCurrentFsm | read-only | Cisco Firepower fabric:SanCloudFsm:currentFsm managed object property |
| STR cfprFabricSanCloudFsmDescrData | 1.3.6.1.4.1.9.9.826.1.26.100.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:SanCloudFsm:descr managed object property |
| CFP cfprFabricSanCloudFsmFsmStatus | 1.3.6.1.4.1.9.9.826.1.26.100.1.7 | CfprFsmFsmStageStatus | read-only | Cisco Firepower fabric:SanCloudFsm:fsmStatus managed object property |
| G32 cfprFabricSanCloudFsmProgress | 1.3.6.1.4.1.9.9.826.1.26.100.1.8 | Gauge32 | read-only | Cisco Firepower fabric:SanCloudFsm:progress managed object property |
| G32 cfprFabricSanCloudFsmRmtErrCode | 1.3.6.1.4.1.9.9.826.1.26.100.1.9 | Gauge32 | read-only | Cisco Firepower fabric:SanCloudFsm:rmtErrCode managed object property |
| STR cfprFabricSanCloudFsmRmtErrDescr | 1.3.6.1.4.1.9.9.826.1.26.100.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:SanCloudFsm:rmtErrDescr managed object property |
| CFP cfprFabricSanCloudFsmRmtRslt | 1.3.6.1.4.1.9.9.826.1.26.100.1.11 | CfprConditionRemoteInvRslt | read-only | Cisco Firepower fabric:SanCloudFsm:rmtRslt managed object property |
| cfprFabricSanCloudFsmStageTable | 1.3.6.1.4.1.9.9.826.1.26.101 | not-accessible | Cisco Firepower fabric:SanCloudFsmStage managed object table | |
| cfprFabricSanCloudFsmStageEntry | 1.3.6.1.4.1.9.9.826.1.26.101.1 | not-accessible | Entry for the cfprFabricSanCloudFsmStageTable table. | |
| CFP cfprFabricSanCloudFsmStageInstanceId | 1.3.6.1.4.1.9.9.826.1.26.101.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSanCloudFsmStageDn | 1.3.6.1.4.1.9.9.826.1.26.101.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SanCloudFsmStage:dn managed object property |
| STR cfprFabricSanCloudFsmStageRn | 1.3.6.1.4.1.9.9.826.1.26.101.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SanCloudFsmStage:rn managed object property |
| STR cfprFabricSanCloudFsmStageDescrData | 1.3.6.1.4.1.9.9.826.1.26.101.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:SanCloudFsmStage:descr managed object property |
| DAT cfprFabricSanCloudFsmStageLastUpdateTime | 1.3.6.1.4.1.9.9.826.1.26.101.1.5 | DateAndTime | read-only | Cisco Firepower fabric:SanCloudFsmStage:lastUpdateTime managed object property |
| CFP cfprFabricSanCloudFsmStageName | 1.3.6.1.4.1.9.9.826.1.26.101.1.6 | CfprFabricSanCloudFsmStageName | read-only | Cisco Firepower fabric:SanCloudFsmStage:name managed object property |
| G32 cfprFabricSanCloudFsmStageOrder | 1.3.6.1.4.1.9.9.826.1.26.101.1.7 | Gauge32 | read-only | Cisco Firepower fabric:SanCloudFsmStage:order managed object property |
| G32 cfprFabricSanCloudFsmStageRetry | 1.3.6.1.4.1.9.9.826.1.26.101.1.8 | Gauge32 | read-only | Cisco Firepower fabric:SanCloudFsmStage:retry managed object property |
| CFP cfprFabricSanCloudFsmStageStageStatus | 1.3.6.1.4.1.9.9.826.1.26.101.1.9 | CfprFsmFsmStageStatus | read-only | Cisco Firepower fabric:SanCloudFsmStage:stageStatus managed object property |
| cfprFabricSanCloudFsmTaskTable | 1.3.6.1.4.1.9.9.826.1.26.102 | not-accessible | Cisco Firepower fabric:SanCloudFsmTask managed object table | |
| cfprFabricSanCloudFsmTaskEntry | 1.3.6.1.4.1.9.9.826.1.26.102.1 | not-accessible | Entry for the cfprFabricSanCloudFsmTaskTable table. | |
| CFP cfprFabricSanCloudFsmTaskInstanceId | 1.3.6.1.4.1.9.9.826.1.26.102.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSanCloudFsmTaskDn | 1.3.6.1.4.1.9.9.826.1.26.102.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SanCloudFsmTask:dn managed object property |
| STR cfprFabricSanCloudFsmTaskRn | 1.3.6.1.4.1.9.9.826.1.26.102.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SanCloudFsmTask:rn managed object property |
| CFP cfprFabricSanCloudFsmTaskCompletion | 1.3.6.1.4.1.9.9.826.1.26.102.1.4 | CfprFsmCompletion | read-only | Cisco Firepower fabric:SanCloudFsmTask:completion managed object property |
| CFP cfprFabricSanCloudFsmTaskFlags | 1.3.6.1.4.1.9.9.826.1.26.102.1.5 | CfprFsmFlags | read-only | Cisco Firepower fabric:SanCloudFsmTask:flags managed object property |
| CFP cfprFabricSanCloudFsmTaskItem | 1.3.6.1.4.1.9.9.826.1.26.102.1.6 | CfprFabricSanCloudFsmTaskItem | read-only | Cisco Firepower fabric:SanCloudFsmTask:item managed object property |
| G32 cfprFabricSanCloudFsmTaskSeqId | 1.3.6.1.4.1.9.9.826.1.26.102.1.7 | Gauge32 | read-only | Cisco Firepower fabric:SanCloudFsmTask:seqId managed object property |
| cfprFabricSanPinGroupTable | 1.3.6.1.4.1.9.9.826.1.26.104 | not-accessible | Cisco Firepower fabric:SanPinGroup managed object table | |
| cfprFabricSanPinGroupEntry | 1.3.6.1.4.1.9.9.826.1.26.104.1 | not-accessible | Entry for the cfprFabricSanPinGroupTable table. | |
| CFP cfprFabricSanPinGroupInstanceId | 1.3.6.1.4.1.9.9.826.1.26.104.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSanPinGroupDn | 1.3.6.1.4.1.9.9.826.1.26.104.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SanPinGroup:dn managed object property |
| STR cfprFabricSanPinGroupRn | 1.3.6.1.4.1.9.9.826.1.26.104.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SanPinGroup:rn managed object property |
| STR cfprFabricSanPinGroupDescr | 1.3.6.1.4.1.9.9.826.1.26.104.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:SanPinGroup:descr managed object property |
| STR cfprFabricSanPinGroupIntId | 1.3.6.1.4.1.9.9.826.1.26.104.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:SanPinGroup:intId managed object property |
| STR cfprFabricSanPinGroupName | 1.3.6.1.4.1.9.9.826.1.26.104.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:SanPinGroup:name managed object property |
| G32 cfprFabricSanPinGroupPolicyLevel | 1.3.6.1.4.1.9.9.826.1.26.104.1.7 | Gauge32 | read-only | Cisco Firepower fabric:SanPinGroup:policyLevel managed object property |
| CFP cfprFabricSanPinGroupPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.104.1.8 | CfprPolicyPolicyOwner | read-only | Cisco Firepower fabric:SanPinGroup:policyOwner managed object property |
| G32 cfprFabricSanPinGroupSize | 1.3.6.1.4.1.9.9.826.1.26.104.1.9 | Gauge32 | read-only | Cisco Firepower fabric:SanPinGroup:size managed object property |
| cfprFabricSanPinTargetTable | 1.3.6.1.4.1.9.9.826.1.26.105 | not-accessible | Cisco Firepower fabric:SanPinTarget managed object table | |
| cfprFabricSanPinTargetEntry | 1.3.6.1.4.1.9.9.826.1.26.105.1 | not-accessible | Entry for the cfprFabricSanPinTargetTable table. | |
| CFP cfprFabricSanPinTargetInstanceId | 1.3.6.1.4.1.9.9.826.1.26.105.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSanPinTargetDn | 1.3.6.1.4.1.9.9.826.1.26.105.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SanPinTarget:dn managed object property |
| STR cfprFabricSanPinTargetRn | 1.3.6.1.4.1.9.9.826.1.26.105.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SanPinTarget:rn managed object property |
| STR cfprFabricSanPinTargetEpDn | 1.3.6.1.4.1.9.9.826.1.26.105.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:SanPinTarget:epDn managed object property |
| STR cfprFabricSanPinTargetFabricId | 1.3.6.1.4.1.9.9.826.1.26.105.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:SanPinTarget:fabricId managed object property |
| CFP cfprFabricSanPinTargetTargetStatus | 1.3.6.1.4.1.9.9.826.1.26.105.1.6 | CfprFabricTargetStatus | read-only | Cisco Firepower fabric:SanPinTarget:targetStatus managed object property |
| cfprFabricSubGroupTable | 1.3.6.1.4.1.9.9.826.1.26.106 | not-accessible | Cisco Firepower fabric:SubGroup managed object table | |
| cfprFabricSubGroupEntry | 1.3.6.1.4.1.9.9.826.1.26.106.1 | not-accessible | Entry for the cfprFabricSubGroupTable table. | |
| CFP cfprFabricSubGroupInstanceId | 1.3.6.1.4.1.9.9.826.1.26.106.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSubGroupDn | 1.3.6.1.4.1.9.9.826.1.26.106.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SubGroup:dn managed object property |
| STR cfprFabricSubGroupRn | 1.3.6.1.4.1.9.9.826.1.26.106.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SubGroup:rn managed object property |
| CFP cfprFabricSubGroupAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.106.1.4 | CfprFabricSubGroupAggrPortId | read-only | Cisco Firepower fabric:SubGroup:aggrPortId managed object property |
| CFP cfprFabricSubGroupConfigState | 1.3.6.1.4.1.9.9.826.1.26.106.1.5 | CfprFabricSubGroupConfigState | read-only | Cisco Firepower fabric:SubGroup:configState managed object property |
| UNS cfprFabricSubGroupLicGP | 1.3.6.1.4.1.9.9.826.1.26.106.1.6 | Unsigned64 | read-only | Cisco Firepower fabric:SubGroup:licGP managed object property |
| CFP cfprFabricSubGroupLicState | 1.3.6.1.4.1.9.9.826.1.26.106.1.7 | CfprLicenseState | read-only | Cisco Firepower fabric:SubGroup:licState managed object property |
| CFP cfprFabricSubGroupLocale | 1.3.6.1.4.1.9.9.826.1.26.106.1.8 | CfprNetworkLocale | read-only | Cisco Firepower fabric:SubGroup:locale managed object property |
| STR cfprFabricSubGroupName | 1.3.6.1.4.1.9.9.826.1.26.106.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:SubGroup:name managed object property |
| CFP cfprFabricSubGroupSlotId | 1.3.6.1.4.1.9.9.826.1.26.106.1.10 | CfprFabricSubGroupSlotId | read-only | Cisco Firepower fabric:SubGroup:slotId managed object property |
| CFP cfprFabricSubGroupSwitchId | 1.3.6.1.4.1.9.9.826.1.26.106.1.11 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:SubGroup:switchId managed object property |
| CFP cfprFabricSubGroupTransport | 1.3.6.1.4.1.9.9.826.1.26.106.1.12 | CfprNetworkTransport | read-only | Cisco Firepower fabric:SubGroup:transport managed object property |
| CFP cfprFabricSubGroupType | 1.3.6.1.4.1.9.9.826.1.26.106.1.13 | CfprNetworkConnectionType | read-only | Cisco Firepower fabric:SubGroup:type managed object property |
| cfprFabricSwChPhEpTable | 1.3.6.1.4.1.9.9.826.1.26.107 | not-accessible | Cisco Firepower fabric:SwChPhEp managed object table | |
| cfprFabricSwChPhEpEntry | 1.3.6.1.4.1.9.9.826.1.26.107.1 | not-accessible | Entry for the cfprFabricSwChPhEpTable table. | |
| CFP cfprFabricSwChPhEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.107.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSwChPhEpDn | 1.3.6.1.4.1.9.9.826.1.26.107.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SwChPhEp:dn managed object property |
| STR cfprFabricSwChPhEpRn | 1.3.6.1.4.1.9.9.826.1.26.107.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SwChPhEp:rn managed object property |
| CFP cfprFabricSwChPhEpAdminState | 1.3.6.1.4.1.9.9.826.1.26.107.1.4 | CfprFabricSwChPhEpAdminState | read-only | Cisco Firepower fabric:SwChPhEp:adminState managed object property |
| G32 cfprFabricSwChPhEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.107.1.5 | Gauge32 | read-only | Cisco Firepower fabric:SwChPhEp:aggrPortId managed object property |
| G32 cfprFabricSwChPhEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.107.1.6 | Gauge32 | read-only | Cisco Firepower fabric:SwChPhEp:chassisId managed object property |
| STR cfprFabricSwChPhEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.107.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:SwChPhEp:epDn managed object property |
| CFP cfprFabricSwChPhEpEqType | 1.3.6.1.4.1.9.9.826.1.26.107.1.8 | CfprEquipmentFabricEpType | read-only | Cisco Firepower fabric:SwChPhEp:eqType managed object property |
| UNS cfprFabricSwChPhEpFltAggr | 1.3.6.1.4.1.9.9.826.1.26.107.1.9 | Unsigned64 | read-only | Cisco Firepower fabric:SwChPhEp:fltAggr managed object property |
| CFP cfprFabricSwChPhEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.107.1.10 | CfprFabricSwChEpIfRole | read-only | Cisco Firepower fabric:SwChPhEp:ifRole managed object property |
| CFP cfprFabricSwChPhEpIfType | 1.3.6.1.4.1.9.9.826.1.26.107.1.11 | CfprFabricPIoEpIfType | read-only | Cisco Firepower fabric:SwChPhEp:ifType managed object property |
| CFP cfprFabricSwChPhEpLc | 1.3.6.1.4.1.9.9.826.1.26.107.1.12 | CfprFabricLifeCycle | read-only | Cisco Firepower fabric:SwChPhEp:lc managed object property |
| UNS cfprFabricSwChPhEpLicGP | 1.3.6.1.4.1.9.9.826.1.26.107.1.13 | Unsigned64 | read-only | Cisco Firepower fabric:SwChPhEp:licGP managed object property |
| CFP cfprFabricSwChPhEpLicState | 1.3.6.1.4.1.9.9.826.1.26.107.1.14 | CfprLicenseState | read-only | Cisco Firepower fabric:SwChPhEp:licState managed object property |
| NUM cfprFabricSwChPhEpLocale | 1.3.6.1.4.1.9.9.826.1.26.107.1.15 | CfprFabricInternalEpLocale | read-only | Cisco Firepower fabric:SwChPhEp:locale managed object property |
| STR cfprFabricSwChPhEpModel | 1.3.6.1.4.1.9.9.826.1.26.107.1.16 | SnmpAdminString | read-only | Cisco Firepower fabric:SwChPhEp:model managed object property |
| STR cfprFabricSwChPhEpName | 1.3.6.1.4.1.9.9.826.1.26.107.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:SwChPhEp:name managed object property |
| CFP cfprFabricSwChPhEpOperState | 1.3.6.1.4.1.9.9.826.1.26.107.1.18 | CfprFabricPIoEpOperState | read-only | Cisco Firepower fabric:SwChPhEp:operState managed object property |
| STR cfprFabricSwChPhEpOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.107.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:SwChPhEp:operStateReason managed object property |
| G32 cfprFabricSwChPhEpPeerAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.107.1.20 | Gauge32 | read-only | Cisco Firepower fabric:SwChPhEp:peerAggrPortId managed object property |
| G32 cfprFabricSwChPhEpPeerChassisId | 1.3.6.1.4.1.9.9.826.1.26.107.1.21 | Gauge32 | read-only | Cisco Firepower fabric:SwChPhEp:peerChassisId managed object property |
| STR cfprFabricSwChPhEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.107.1.22 | SnmpAdminString | read-only | Cisco Firepower fabric:SwChPhEp:peerDn managed object property |
| G32 cfprFabricSwChPhEpPeerPortId | 1.3.6.1.4.1.9.9.826.1.26.107.1.23 | Gauge32 | read-only | Cisco Firepower fabric:SwChPhEp:peerPortId managed object property |
| G32 cfprFabricSwChPhEpPeerSlotId | 1.3.6.1.4.1.9.9.826.1.26.107.1.24 | Gauge32 | read-only | Cisco Firepower fabric:SwChPhEp:peerSlotId managed object property |
| CFP cfprFabricSwChPhEpPortId | 1.3.6.1.4.1.9.9.826.1.26.107.1.25 | CfprFabricPIoEpPortId | read-only | Cisco Firepower fabric:SwChPhEp:portId managed object property |
| STR cfprFabricSwChPhEpRevision | 1.3.6.1.4.1.9.9.826.1.26.107.1.26 | SnmpAdminString | read-only | Cisco Firepower fabric:SwChPhEp:revision managed object property |
| STR cfprFabricSwChPhEpSerial | 1.3.6.1.4.1.9.9.826.1.26.107.1.27 | SnmpAdminString | read-only | Cisco Firepower fabric:SwChPhEp:serial managed object property |
| CFP cfprFabricSwChPhEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.107.1.28 | CfprFabricPIoEpSlotId | read-only | Cisco Firepower fabric:SwChPhEp:slotId managed object property |
| CFP cfprFabricSwChPhEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.107.1.29 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:SwChPhEp:switchId managed object property |
| CFP cfprFabricSwChPhEpTransport | 1.3.6.1.4.1.9.9.826.1.26.107.1.30 | CfprNetworkTransport | read-only | Cisco Firepower fabric:SwChPhEp:transport managed object property |
| CFP cfprFabricSwChPhEpType | 1.3.6.1.4.1.9.9.826.1.26.107.1.31 | CfprFabricSwChEpType | read-only | Cisco Firepower fabric:SwChPhEp:type managed object property |
| STR cfprFabricSwChPhEpVendor | 1.3.6.1.4.1.9.9.826.1.26.107.1.32 | SnmpAdminString | read-only | Cisco Firepower fabric:SwChPhEp:vendor managed object property |
| cfprFabricSwSubGroupTable | 1.3.6.1.4.1.9.9.826.1.26.108 | not-accessible | Cisco Firepower fabric:SwSubGroup managed object table | |
| cfprFabricSwSubGroupEntry | 1.3.6.1.4.1.9.9.826.1.26.108.1 | not-accessible | Entry for the cfprFabricSwSubGroupTable table. | |
| CFP cfprFabricSwSubGroupInstanceId | 1.3.6.1.4.1.9.9.826.1.26.108.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSwSubGroupDn | 1.3.6.1.4.1.9.9.826.1.26.108.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SwSubGroup:dn managed object property |
| STR cfprFabricSwSubGroupRn | 1.3.6.1.4.1.9.9.826.1.26.108.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SwSubGroup:rn managed object property |
| CFP cfprFabricSwSubGroupAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.108.1.4 | CfprFabricSwSubGroupAggrPortId | read-only | Cisco Firepower fabric:SwSubGroup:aggrPortId managed object property |
| CFP cfprFabricSwSubGroupConfigState | 1.3.6.1.4.1.9.9.826.1.26.108.1.5 | CfprFabricSwSubGroupConfigState | read-only | Cisco Firepower fabric:SwSubGroup:configState managed object property |
| UNS cfprFabricSwSubGroupLicGP | 1.3.6.1.4.1.9.9.826.1.26.108.1.6 | Unsigned64 | read-only | Cisco Firepower fabric:SwSubGroup:licGP managed object property |
| CFP cfprFabricSwSubGroupLicState | 1.3.6.1.4.1.9.9.826.1.26.108.1.7 | CfprLicenseState | read-only | Cisco Firepower fabric:SwSubGroup:licState managed object property |
| CFP cfprFabricSwSubGroupLocale | 1.3.6.1.4.1.9.9.826.1.26.108.1.8 | CfprNetworkLocale | read-only | Cisco Firepower fabric:SwSubGroup:locale managed object property |
| STR cfprFabricSwSubGroupName | 1.3.6.1.4.1.9.9.826.1.26.108.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:SwSubGroup:name managed object property |
| CFP cfprFabricSwSubGroupSlotId | 1.3.6.1.4.1.9.9.826.1.26.108.1.10 | CfprFabricSwSubGroupSlotId | read-only | Cisco Firepower fabric:SwSubGroup:slotId managed object property |
| CFP cfprFabricSwSubGroupSwitchId | 1.3.6.1.4.1.9.9.826.1.26.108.1.11 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:SwSubGroup:switchId managed object property |
| CFP cfprFabricSwSubGroupTransport | 1.3.6.1.4.1.9.9.826.1.26.108.1.12 | CfprNetworkTransport | read-only | Cisco Firepower fabric:SwSubGroup:transport managed object property |
| CFP cfprFabricSwSubGroupType | 1.3.6.1.4.1.9.9.826.1.26.108.1.13 | CfprNetworkConnectionType | read-only | Cisco Firepower fabric:SwSubGroup:type managed object property |
| cfprFabricUdldLinkPolicyTable | 1.3.6.1.4.1.9.9.826.1.26.109 | not-accessible | Cisco Firepower fabric:UdldLinkPolicy managed object table | |
| cfprFabricUdldLinkPolicyEntry | 1.3.6.1.4.1.9.9.826.1.26.109.1 | not-accessible | Entry for the cfprFabricUdldLinkPolicyTable table. | |
| CFP cfprFabricUdldLinkPolicyInstanceId | 1.3.6.1.4.1.9.9.826.1.26.109.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricUdldLinkPolicyDn | 1.3.6.1.4.1.9.9.826.1.26.109.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:UdldLinkPolicy:dn managed object property |
| STR cfprFabricUdldLinkPolicyRn | 1.3.6.1.4.1.9.9.826.1.26.109.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:UdldLinkPolicy:rn managed object property |
| CFP cfprFabricUdldLinkPolicyAdminState | 1.3.6.1.4.1.9.9.826.1.26.109.1.4 | CfprFabricUdldLinkPolicyAdminState | read-only | Cisco Firepower fabric:UdldLinkPolicy:adminState managed object property |
| STR cfprFabricUdldLinkPolicyDescr | 1.3.6.1.4.1.9.9.826.1.26.109.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:UdldLinkPolicy:descr managed object property |
| STR cfprFabricUdldLinkPolicyIntId | 1.3.6.1.4.1.9.9.826.1.26.109.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:UdldLinkPolicy:intId managed object property |
| CFP cfprFabricUdldLinkPolicyMode | 1.3.6.1.4.1.9.9.826.1.26.109.1.7 | CfprFabricUdldLinkPolicyMode | read-only | Cisco Firepower fabric:UdldLinkPolicy:mode managed object property |
| STR cfprFabricUdldLinkPolicyName | 1.3.6.1.4.1.9.9.826.1.26.109.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:UdldLinkPolicy:name managed object property |
| G32 cfprFabricUdldLinkPolicyPolicyLevel | 1.3.6.1.4.1.9.9.826.1.26.109.1.9 | Gauge32 | read-only | Cisco Firepower fabric:UdldLinkPolicy:policyLevel managed object property |
| CFP cfprFabricUdldLinkPolicyPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.109.1.10 | CfprPolicyPolicyOwner | read-only | Cisco Firepower fabric:UdldLinkPolicy:policyOwner managed object property |
| CFP cfprFabricUdldLinkPolicyProtocol | 1.3.6.1.4.1.9.9.826.1.26.109.1.11 | CfprFabricEthUdldPolicyProtocol | read-only | Cisco Firepower fabric:UdldLinkPolicy:protocol managed object property |
| CFP cfprFabricUdldLinkPolicyType | 1.3.6.1.4.1.9.9.826.1.26.109.1.12 | CfprFabricEthLinkPolicyType | read-only | Cisco Firepower fabric:UdldLinkPolicy:type managed object property |
| cfprFabricUdldPolicyTable | 1.3.6.1.4.1.9.9.826.1.26.110 | not-accessible | Cisco Firepower fabric:UdldPolicy managed object table | |
| cfprFabricUdldPolicyEntry | 1.3.6.1.4.1.9.9.826.1.26.110.1 | not-accessible | Entry for the cfprFabricUdldPolicyTable table. | |
| CFP cfprFabricUdldPolicyInstanceId | 1.3.6.1.4.1.9.9.826.1.26.110.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricUdldPolicyDn | 1.3.6.1.4.1.9.9.826.1.26.110.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:UdldPolicy:dn managed object property |
| STR cfprFabricUdldPolicyRn | 1.3.6.1.4.1.9.9.826.1.26.110.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:UdldPolicy:rn managed object property |
| STR cfprFabricUdldPolicyDescr | 1.3.6.1.4.1.9.9.826.1.26.110.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:UdldPolicy:descr managed object property |
| STR cfprFabricUdldPolicyIntId | 1.3.6.1.4.1.9.9.826.1.26.110.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:UdldPolicy:intId managed object property |
| G32 cfprFabricUdldPolicyMsgInterval | 1.3.6.1.4.1.9.9.826.1.26.110.1.6 | Gauge32 | read-only | Cisco Firepower fabric:UdldPolicy:msgInterval managed object property |
| STR cfprFabricUdldPolicyName | 1.3.6.1.4.1.9.9.826.1.26.110.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:UdldPolicy:name managed object property |
| G32 cfprFabricUdldPolicyPolicyLevel | 1.3.6.1.4.1.9.9.826.1.26.110.1.8 | Gauge32 | read-only | Cisco Firepower fabric:UdldPolicy:policyLevel managed object property |
| CFP cfprFabricUdldPolicyPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.110.1.9 | CfprPolicyPolicyOwner | read-only | Cisco Firepower fabric:UdldPolicy:policyOwner managed object property |
| CFP cfprFabricUdldPolicyRecoveryAction | 1.3.6.1.4.1.9.9.826.1.26.110.1.10 | CfprFabricRecoveryAction | read-only | Cisco Firepower fabric:UdldPolicy:recoveryAction managed object property |
| cfprFabricVConTable | 1.3.6.1.4.1.9.9.826.1.26.111 | not-accessible | Cisco Firepower fabric:VCon managed object table | |
| cfprFabricVConEntry | 1.3.6.1.4.1.9.9.826.1.26.111.1 | not-accessible | Entry for the cfprFabricVConTable table. | |
| CFP cfprFabricVConInstanceId | 1.3.6.1.4.1.9.9.826.1.26.111.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVConDn | 1.3.6.1.4.1.9.9.826.1.26.111.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:VCon:dn managed object property |
| STR cfprFabricVConRn | 1.3.6.1.4.1.9.9.826.1.26.111.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:VCon:rn managed object property |
| STR cfprFabricVConEquipmentDn | 1.3.6.1.4.1.9.9.826.1.26.111.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:VCon:equipmentDn managed object property |
| STR cfprFabricVConFabric | 1.3.6.1.4.1.9.9.826.1.26.111.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:VCon:fabric managed object property |
| STR cfprFabricVConId | 1.3.6.1.4.1.9.9.826.1.26.111.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:VCon:id managed object property |
| CFP cfprFabricVConInstType | 1.3.6.1.4.1.9.9.826.1.26.111.1.7 | CfprFabricVConInstType | read-only | Cisco Firepower fabric:VCon:instType managed object property |
| CFP cfprFabricVConPlacement | 1.3.6.1.4.1.9.9.826.1.26.111.1.8 | CfprFabricVConPlacementPref | read-only | Cisco Firepower fabric:VCon:placement managed object property |
| CFP cfprFabricVConSelect | 1.3.6.1.4.1.9.9.826.1.26.111.1.9 | CfprFabricVConSelectPref | read-only | Cisco Firepower fabric:VCon:select managed object property |
| CFP cfprFabricVConShare | 1.3.6.1.4.1.9.9.826.1.26.111.1.10 | CfprFabricVConSharePref | read-only | Cisco Firepower fabric:VCon:share managed object property |
| CFP cfprFabricVConTransport | 1.3.6.1.4.1.9.9.826.1.26.111.1.11 | CfprFabricVConTransportPref | read-only | Cisco Firepower fabric:VCon:transport managed object property |
| cfprFabricVConProfileTable | 1.3.6.1.4.1.9.9.826.1.26.112 | not-accessible | Cisco Firepower fabric:VConProfile managed object table | |
| cfprFabricVConProfileEntry | 1.3.6.1.4.1.9.9.826.1.26.112.1 | not-accessible | Entry for the cfprFabricVConProfileTable table. | |
| CFP cfprFabricVConProfileInstanceId | 1.3.6.1.4.1.9.9.826.1.26.112.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVConProfileDn | 1.3.6.1.4.1.9.9.826.1.26.112.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:VConProfile:dn managed object property |
| STR cfprFabricVConProfileRn | 1.3.6.1.4.1.9.9.826.1.26.112.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:VConProfile:rn managed object property |
| STR cfprFabricVConProfileDescr | 1.3.6.1.4.1.9.9.826.1.26.112.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:VConProfile:descr managed object property |
| STR cfprFabricVConProfileIntId | 1.3.6.1.4.1.9.9.826.1.26.112.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:VConProfile:intId managed object property |
| CFP cfprFabricVConProfileMezzMapping | 1.3.6.1.4.1.9.9.826.1.26.112.1.6 | CfprFabricVConMappingScheme | read-only | Cisco Firepower fabric:VConProfile:mezzMapping managed object property |
| STR cfprFabricVConProfileName | 1.3.6.1.4.1.9.9.826.1.26.112.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:VConProfile:name managed object property |
| G32 cfprFabricVConProfilePolicyLevel | 1.3.6.1.4.1.9.9.826.1.26.112.1.8 | Gauge32 | read-only | Cisco Firepower fabric:VConProfile:policyLevel managed object property |
| CFP cfprFabricVConProfilePolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.112.1.9 | CfprPolicyPolicyOwner | read-only | Cisco Firepower fabric:VConProfile:policyOwner managed object property |
| cfprFabricVlanTable | 1.3.6.1.4.1.9.9.826.1.26.113 | not-accessible | Cisco Firepower fabric:Vlan managed object table | |
| cfprFabricVlanEntry | 1.3.6.1.4.1.9.9.826.1.26.113.1 | not-accessible | Entry for the cfprFabricVlanTable table. | |
| CFP cfprFabricVlanInstanceId | 1.3.6.1.4.1.9.9.826.1.26.113.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVlanDn | 1.3.6.1.4.1.9.9.826.1.26.113.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:Vlan:dn managed object property |
| STR cfprFabricVlanRn | 1.3.6.1.4.1.9.9.826.1.26.113.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:Vlan:rn managed object property |
| CFP cfprFabricVlanAssocPrimaryVlanState | 1.3.6.1.4.1.9.9.826.1.26.113.1.4 | CfprFabricVlanAssocPrimaryVlanState | read-only | Cisco Firepower fabric:Vlan:assocPrimaryVlanState managed object property |
| CFP cfprFabricVlanAssocPrimaryVlanSwitchId | 1.3.6.1.4.1.9.9.826.1.26.113.1.5 | CfprFabricAVlanAssocPrimaryVlanSwitchId | read-only | Cisco Firepower fabric:Vlan:assocPrimaryVlanSwitchId managed object property |
| CFP cfprFabricVlanCloud | 1.3.6.1.4.1.9.9.826.1.26.113.1.6 | CfprFabricCloudType | read-only | Cisco Firepower fabric:Vlan:cloud managed object property |
| CFP cfprFabricVlanCompressionType | 1.3.6.1.4.1.9.9.826.1.26.113.1.7 | CfprFabricVlanCompType | read-only | Cisco Firepower fabric:Vlan:compressionType managed object property |
| CFP cfprFabricVlanConfigIssues | 1.3.6.1.4.1.9.9.826.1.26.113.1.8 | CfprFabricVlanConfigIssues | read-only | Cisco Firepower fabric:Vlan:configIssues managed object property |
| T/F cfprFabricVlanDefaultNet | 1.3.6.1.4.1.9.9.826.1.26.113.1.9 | TruthValue | read-only | Cisco Firepower fabric:Vlan:defaultNet managed object property |
| STR cfprFabricVlanEpDn | 1.3.6.1.4.1.9.9.826.1.26.113.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:Vlan:epDn managed object property |
| UNS cfprFabricVlanFltAggr | 1.3.6.1.4.1.9.9.826.1.26.113.1.11 | Unsigned64 | read-only | Cisco Firepower fabric:Vlan:fltAggr managed object property |
| UNS cfprFabricVlanGlobal | 1.3.6.1.4.1.9.9.826.1.26.113.1.12 | Unsigned64 | read-only | Cisco Firepower fabric:Vlan:global managed object property |
| G32 cfprFabricVlanId | 1.3.6.1.4.1.9.9.826.1.26.113.1.13 | Gauge32 | read-only | Cisco Firepower fabric:Vlan:id managed object property |
| CFP cfprFabricVlanIfRole | 1.3.6.1.4.1.9.9.826.1.26.113.1.14 | CfprFabricVnetEpIfRole | read-only | Cisco Firepower fabric:Vlan:ifRole managed object property |
| CFP cfprFabricVlanIfType | 1.3.6.1.4.1.9.9.826.1.26.113.1.15 | CfprNetworkVnetEpIfType | read-only | Cisco Firepower fabric:Vlan:ifType managed object property |
| UNS cfprFabricVlanLocal | 1.3.6.1.4.1.9.9.826.1.26.113.1.16 | Unsigned64 | read-only | Cisco Firepower fabric:Vlan:local managed object property |
| CFP cfprFabricVlanLocale | 1.3.6.1.4.1.9.9.826.1.26.113.1.17 | CfprFabricVnetEpLocale | read-only | Cisco Firepower fabric:Vlan:locale managed object property |
| STR cfprFabricVlanMcastPolicyName | 1.3.6.1.4.1.9.9.826.1.26.113.1.18 | SnmpAdminString | read-only | Cisco Firepower fabric:Vlan:mcastPolicyName managed object property |
| STR cfprFabricVlanName | 1.3.6.1.4.1.9.9.826.1.26.113.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:Vlan:name managed object property |
| STR cfprFabricVlanOperMcastPolicyName | 1.3.6.1.4.1.9.9.826.1.26.113.1.20 | SnmpAdminString | read-only | Cisco Firepower fabric:Vlan:operMcastPolicyName managed object property |
| CFP cfprFabricVlanOperState | 1.3.6.1.4.1.9.9.826.1.26.113.1.21 | CfprFabricVlanOperState | read-only | Cisco Firepower fabric:Vlan:operState managed object property |
| CFP cfprFabricVlanOverlapStateForA | 1.3.6.1.4.1.9.9.826.1.26.113.1.22 | CfprFabricVlanOverlapState | read-only | Cisco Firepower fabric:Vlan:overlapStateForA managed object property |
| CFP cfprFabricVlanOverlapStateForB | 1.3.6.1.4.1.9.9.826.1.26.113.1.23 | CfprFabricVlanOverlapState | read-only | Cisco Firepower fabric:Vlan:overlapStateForB managed object property |
| STR cfprFabricVlanPeerDn | 1.3.6.1.4.1.9.9.826.1.26.113.1.24 | SnmpAdminString | read-only | Cisco Firepower fabric:Vlan:peerDn managed object property |
| CFP cfprFabricVlanPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.113.1.25 | CfprFabricVnetEpPolicyOwner | read-only | Cisco Firepower fabric:Vlan:policyOwner managed object property |
| STR cfprFabricVlanPubNwDn | 1.3.6.1.4.1.9.9.826.1.26.113.1.26 | SnmpAdminString | read-only | Cisco Firepower fabric:Vlan:pubNwDn managed object property |
| G32 cfprFabricVlanPubNwId | 1.3.6.1.4.1.9.9.826.1.26.113.1.27 | Gauge32 | read-only | Cisco Firepower fabric:Vlan:pubNwId managed object property |
| STR cfprFabricVlanPubNwName | 1.3.6.1.4.1.9.9.826.1.26.113.1.28 | SnmpAdminString | read-only | Cisco Firepower fabric:Vlan:pubNwName managed object property |
| CFP cfprFabricVlanSharing | 1.3.6.1.4.1.9.9.826.1.26.113.1.29 | CfprFabricAVlanSharing | read-only | Cisco Firepower fabric:Vlan:sharing managed object property |
| CFP cfprFabricVlanSwitchId | 1.3.6.1.4.1.9.9.826.1.26.113.1.30 | CfprFabricVlanSwitchId | read-only | Cisco Firepower fabric:Vlan:switchId managed object property |
| CFP cfprFabricVlanTransport | 1.3.6.1.4.1.9.9.826.1.26.113.1.31 | CfprFabricAVlanTransport | read-only | Cisco Firepower fabric:Vlan:transport managed object property |
| CFP cfprFabricVlanType | 1.3.6.1.4.1.9.9.826.1.26.113.1.32 | CfprFabricAVlanType | read-only | Cisco Firepower fabric:Vlan:type managed object property |
| cfprFabricVlanEpTable | 1.3.6.1.4.1.9.9.826.1.26.114 | not-accessible | Cisco Firepower fabric:VlanEp managed object table | |
| cfprFabricVlanEpEntry | 1.3.6.1.4.1.9.9.826.1.26.114.1 | not-accessible | Entry for the cfprFabricVlanEpTable table. | |
| CFP cfprFabricVlanEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.114.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVlanEpDnData | 1.3.6.1.4.1.9.9.826.1.26.114.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:VlanEp:dn managed object property |
| STR cfprFabricVlanEpRn | 1.3.6.1.4.1.9.9.826.1.26.114.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanEp:rn managed object property |
| CFP cfprFabricVlanEpAssocPrimaryVlanState | 1.3.6.1.4.1.9.9.826.1.26.114.1.4 | CfprFabricVlanAssocPrimaryVlanState | read-only | Cisco Firepower fabric:VlanEp:assocPrimaryVlanState managed object property |
| CFP cfprFabricVlanEpAssocPrimaryVlanSwitchId | 1.3.6.1.4.1.9.9.826.1.26.114.1.5 | CfprFabricAVlanAssocPrimaryVlanSwitchId | read-only | Cisco Firepower fabric:VlanEp:assocPrimaryVlanSwitchId managed object property |
| STR cfprFabricVlanEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.114.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanEp:epDn managed object property |
| G32 cfprFabricVlanEpId | 1.3.6.1.4.1.9.9.826.1.26.114.1.7 | Gauge32 | read-only | Cisco Firepower fabric:VlanEp:id managed object property |
| CFP cfprFabricVlanEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.114.1.8 | CfprFabricVnetEpIfRole | read-only | Cisco Firepower fabric:VlanEp:ifRole managed object property |
| CFP cfprFabricVlanEpIfType | 1.3.6.1.4.1.9.9.826.1.26.114.1.9 | CfprNetworkVnetEpIfType | read-only | Cisco Firepower fabric:VlanEp:ifType managed object property |
| T/F cfprFabricVlanEpIsNative | 1.3.6.1.4.1.9.9.826.1.26.114.1.10 | TruthValue | read-only | Cisco Firepower fabric:VlanEp:isNative managed object property |
| CFP cfprFabricVlanEpLocale | 1.3.6.1.4.1.9.9.826.1.26.114.1.11 | CfprFabricVnetEpLocale | read-only | Cisco Firepower fabric:VlanEp:locale managed object property |
| STR cfprFabricVlanEpName | 1.3.6.1.4.1.9.9.826.1.26.114.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanEp:name managed object property |
| CFP cfprFabricVlanEpOperState | 1.3.6.1.4.1.9.9.826.1.26.114.1.13 | CfprFabricVlanOperState | read-only | Cisco Firepower fabric:VlanEp:operState managed object property |
| CFP cfprFabricVlanEpOverlapStateForA | 1.3.6.1.4.1.9.9.826.1.26.114.1.14 | CfprFabricVlanOverlapState | read-only | Cisco Firepower fabric:VlanEp:overlapStateForA managed object property |
| CFP cfprFabricVlanEpOverlapStateForB | 1.3.6.1.4.1.9.9.826.1.26.114.1.15 | CfprFabricVlanOverlapState | read-only | Cisco Firepower fabric:VlanEp:overlapStateForB managed object property |
| STR cfprFabricVlanEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.114.1.16 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanEp:peerDn managed object property |
| CFP cfprFabricVlanEpPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.114.1.17 | CfprFabricVnetEpPolicyOwner | read-only | Cisco Firepower fabric:VlanEp:policyOwner managed object property |
| STR cfprFabricVlanEpPubNwDn | 1.3.6.1.4.1.9.9.826.1.26.114.1.18 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanEp:pubNwDn managed object property |
| G32 cfprFabricVlanEpPubNwId | 1.3.6.1.4.1.9.9.826.1.26.114.1.19 | Gauge32 | read-only | Cisco Firepower fabric:VlanEp:pubNwId managed object property |
| STR cfprFabricVlanEpPubNwName | 1.3.6.1.4.1.9.9.826.1.26.114.1.20 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanEp:pubNwName managed object property |
| CFP cfprFabricVlanEpSharing | 1.3.6.1.4.1.9.9.826.1.26.114.1.21 | CfprFabricAVlanSharing | read-only | Cisco Firepower fabric:VlanEp:sharing managed object property |
| CFP cfprFabricVlanEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.114.1.22 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:VlanEp:switchId managed object property |
| CFP cfprFabricVlanEpTransport | 1.3.6.1.4.1.9.9.826.1.26.114.1.23 | CfprFabricAVlanTransport | read-only | Cisco Firepower fabric:VlanEp:transport managed object property |
| CFP cfprFabricVlanEpType | 1.3.6.1.4.1.9.9.826.1.26.114.1.24 | CfprFabricAVlanType | read-only | Cisco Firepower fabric:VlanEp:type managed object property |
| cfprFabricVlanGroupReqTable | 1.3.6.1.4.1.9.9.826.1.26.115 | not-accessible | Cisco Firepower fabric:VlanGroupReq managed object table | |
| cfprFabricVlanGroupReqEntry | 1.3.6.1.4.1.9.9.826.1.26.115.1 | not-accessible | Entry for the cfprFabricVlanGroupReqTable table. | |
| CFP cfprFabricVlanGroupReqInstanceId | 1.3.6.1.4.1.9.9.826.1.26.115.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVlanGroupReqDn | 1.3.6.1.4.1.9.9.826.1.26.115.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:VlanGroupReq:dn managed object property |
| STR cfprFabricVlanGroupReqRn | 1.3.6.1.4.1.9.9.826.1.26.115.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanGroupReq:rn managed object property |
| CFP cfprFabricVlanGroupReqConfigIssues | 1.3.6.1.4.1.9.9.826.1.26.115.1.4 | CfprFabricReqIssues | read-only | Cisco Firepower fabric:VlanGroupReq:configIssues managed object property |
| STR cfprFabricVlanGroupReqName | 1.3.6.1.4.1.9.9.826.1.26.115.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanGroupReq:name managed object property |
| CFP cfprFabricVlanGroupReqType | 1.3.6.1.4.1.9.9.826.1.26.115.1.6 | CfprFabricAccessType | read-only | Cisco Firepower fabric:VlanGroupReq:type managed object property |
| cfprFabricVlanPermitTable | 1.3.6.1.4.1.9.9.826.1.26.116 | not-accessible | Cisco Firepower fabric:VlanPermit managed object table | |
| cfprFabricVlanPermitEntry | 1.3.6.1.4.1.9.9.826.1.26.116.1 | not-accessible | Entry for the cfprFabricVlanPermitTable table. | |
| CFP cfprFabricVlanPermitInstanceId | 1.3.6.1.4.1.9.9.826.1.26.116.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVlanPermitDn | 1.3.6.1.4.1.9.9.826.1.26.116.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:VlanPermit:dn managed object property |
| STR cfprFabricVlanPermitRn | 1.3.6.1.4.1.9.9.826.1.26.116.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanPermit:rn managed object property |
| CFP cfprFabricVlanPermitCloud | 1.3.6.1.4.1.9.9.826.1.26.116.1.4 | CfprFabricCloudType | read-only | Cisco Firepower fabric:VlanPermit:cloud managed object property |
| STR cfprFabricVlanPermitName | 1.3.6.1.4.1.9.9.826.1.26.116.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanPermit:name managed object property |
| STR cfprFabricVlanPermitSwitchId | 1.3.6.1.4.1.9.9.826.1.26.116.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanPermit:switchId managed object property |
| cfprFabricVlanReqTable | 1.3.6.1.4.1.9.9.826.1.26.117 | not-accessible | Cisco Firepower fabric:VlanReq managed object table | |
| cfprFabricVlanReqEntry | 1.3.6.1.4.1.9.9.826.1.26.117.1 | not-accessible | Entry for the cfprFabricVlanReqTable table. | |
| CFP cfprFabricVlanReqInstanceId | 1.3.6.1.4.1.9.9.826.1.26.117.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVlanReqDn | 1.3.6.1.4.1.9.9.826.1.26.117.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:VlanReq:dn managed object property |
| STR cfprFabricVlanReqRn | 1.3.6.1.4.1.9.9.826.1.26.117.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanReq:rn managed object property |
| CFP cfprFabricVlanReqConfigIssues | 1.3.6.1.4.1.9.9.826.1.26.117.1.4 | CfprFabricReqIssues | read-only | Cisco Firepower fabric:VlanReq:configIssues managed object property |
| STR cfprFabricVlanReqName | 1.3.6.1.4.1.9.9.826.1.26.117.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:VlanReq:name managed object property |
| CFP cfprFabricVlanReqType | 1.3.6.1.4.1.9.9.826.1.26.117.1.6 | CfprFabricAccessType | read-only | Cisco Firepower fabric:VlanReq:type managed object property |
| cfprFabricVnetEpSyncEpTable | 1.3.6.1.4.1.9.9.826.1.26.118 | not-accessible | Cisco Firepower fabric:VnetEpSyncEp managed object table | |
| cfprFabricVnetEpSyncEpEntry | 1.3.6.1.4.1.9.9.826.1.26.118.1 | not-accessible | Entry for the cfprFabricVnetEpSyncEpTable table. | |
| CFP cfprFabricVnetEpSyncEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.118.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVnetEpSyncEpDn | 1.3.6.1.4.1.9.9.826.1.26.118.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:VnetEpSyncEp:dn managed object property |
| STR cfprFabricVnetEpSyncEpRn | 1.3.6.1.4.1.9.9.826.1.26.118.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:VnetEpSyncEp:rn managed object property |
| STR cfprFabricVnetEpSyncEpFsmDescr | 1.3.6.1.4.1.9.9.826.1.26.118.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:VnetEpSyncEp:fsmDescr managed object property |
| STR cfprFabricVnetEpSyncEpFsmPrev | 1.3.6.1.4.1.9.9.826.1.26.118.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:VnetEpSyncEp:fsmPrev managed object property |
| G32 cfprFabricVnetEpSyncEpFsmProgr | 1.3.6.1.4.1.9.9.826.1.26.118.1.6 | Gauge32 | read-only | Cisco Firepower fabric:VnetEpSyncEp:fsmProgr managed object property |
| G32 cfprFabricVnetEpSyncEpFsmRmtInvErrCode | 1.3.6.1.4.1.9.9.826.1.26.118.1.7 | Gauge32 | read-only | Cisco Firepower fabric:VnetEpSyncEp:fsmRmtInvErrCode managed object property |
| STR cfprFabricVnetEpSyncEpFsmRmtInvErrDescr | 1.3.6.1.4.1.9.9.826.1.26.118.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:VnetEpSyncEp:fsmRmtInvErrDescr managed object property |
| CFP cfprFabricVnetEpSyncEpFsmRmtInvRslt | 1.3.6.1.4.1.9.9.826.1.26.118.1.9 | CfprConditionRemoteInvRslt | read-only | Cisco Firepower fabric:VnetEpSyncEp:fsmRmtInvRslt managed object property |
| STR cfprFabricVnetEpSyncEpFsmStageDescr | 1.3.6.1.4.1.9.9.826.1.26.118.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:VnetEpSyncEp:fsmStageDescr managed object property |
| DAT cfprFabricVnetEpSyncEpFsmStamp | 1.3.6.1.4.1.9.9.826.1.26.118.1.11 | DateAndTime | read-only | Cisco Firepower fabric:VnetEpSyncEp:fsmStamp managed object property |
| STR cfprFabricVnetEpSyncEpFsmStatus | 1.3.6.1.4.1.9.9.826.1.26.118.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:VnetEpSyncEp:fsmStatus managed object property |
| G32 cfprFabricVnetEpSyncEpFsmTry | 1.3.6.1.4.1.9.9.826.1.26.118.1.13 | Gauge32 | read-only | Cisco Firepower fabric:VnetEpSyncEp:fsmTry managed object property |
| G32 cfprFabricVnetEpSyncEpGenNumSync | 1.3.6.1.4.1.9.9.826.1.26.118.1.14 | Gauge32 | read-only | Cisco Firepower fabric:VnetEpSyncEp:genNumSync managed object property |
| G32 cfprFabricVnetEpSyncEpId | 1.3.6.1.4.1.9.9.826.1.26.118.1.15 | Gauge32 | read-only | Cisco Firepower fabric:VnetEpSyncEp:id managed object property |
| T/F cfprFabricVnetEpSyncEpIsChangedObjectUpdate | 1.3.6.1.4.1.9.9.826.1.26.118.1.16 | TruthValue | read-only | Cisco Firepower fabric:VnetEpSyncEp:isChangedObjectUpdate managed object property |
| cfprFabricVnetEpSyncEpFsmTable | 1.3.6.1.4.1.9.9.826.1.26.119 | not-accessible | Cisco Firepower fabric:VnetEpSyncEpFsm managed object table | |
| cfprFabricVnetEpSyncEpFsmEntry | 1.3.6.1.4.1.9.9.826.1.26.119.1 | not-accessible | Entry for the cfprFabricVnetEpSyncEpFsmTable table. | |
| CFP cfprFabricVnetEpSyncEpFsmInstanceId | 1.3.6.1.4.1.9.9.826.1.26.119.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVnetEpSyncEpFsmDn | 1.3.6.1.4.1.9.9.826.1.26.119.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:VnetEpSyncEpFsm:dn managed object property |
| STR cfprFabricVnetEpSyncEpFsmRn | 1.3.6.1.4.1.9.9.826.1.26.119.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:VnetEpSyncEpFsm:rn managed object property |
| DAT cfprFabricVnetEpSyncEpFsmCompletionTime | 1.3.6.1.4.1.9.9.826.1.26.119.1.4 | DateAndTime | read-only | Cisco Firepower fabric:VnetEpSyncEpFsm:completionTime managed object property |
| CFP cfprFabricVnetEpSyncEpFsmCurrentFsm | 1.3.6.1.4.1.9.9.826.1.26.119.1.5 | CfprFabricVnetEpSyncEpFsmCurrentFsm | read-only | Cisco Firepower fabric:VnetEpSyncEpFsm:currentFsm managed object property |
| STR cfprFabricVnetEpSyncEpFsmDescrData | 1.3.6.1.4.1.9.9.826.1.26.119.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:VnetEpSyncEpFsm:descr managed object property |
| CFP cfprFabricVnetEpSyncEpFsmFsmStatus | 1.3.6.1.4.1.9.9.826.1.26.119.1.7 | CfprFsmFsmStageStatus | read-only | Cisco Firepower fabric:VnetEpSyncEpFsm:fsmStatus managed object property |
| G32 cfprFabricVnetEpSyncEpFsmProgress | 1.3.6.1.4.1.9.9.826.1.26.119.1.8 | Gauge32 | read-only | Cisco Firepower fabric:VnetEpSyncEpFsm:progress managed object property |
| G32 cfprFabricVnetEpSyncEpFsmRmtErrCode | 1.3.6.1.4.1.9.9.826.1.26.119.1.9 | Gauge32 | read-only | Cisco Firepower fabric:VnetEpSyncEpFsm:rmtErrCode managed object property |
| STR cfprFabricVnetEpSyncEpFsmRmtErrDescr | 1.3.6.1.4.1.9.9.826.1.26.119.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:VnetEpSyncEpFsm:rmtErrDescr managed object property |
| CFP cfprFabricVnetEpSyncEpFsmRmtRslt | 1.3.6.1.4.1.9.9.826.1.26.119.1.11 | CfprConditionRemoteInvRslt | read-only | Cisco Firepower fabric:VnetEpSyncEpFsm:rmtRslt managed object property |
| cfprFabricVnetEpSyncEpFsmStageTable | 1.3.6.1.4.1.9.9.826.1.26.120 | not-accessible | Cisco Firepower fabric:VnetEpSyncEpFsmStage managed object table | |
| cfprFabricVnetEpSyncEpFsmStageEntry | 1.3.6.1.4.1.9.9.826.1.26.120.1 | not-accessible | Entry for the cfprFabricVnetEpSyncEpFsmStageTable table. | |
| CFP cfprFabricVnetEpSyncEpFsmStageInstanceId | 1.3.6.1.4.1.9.9.826.1.26.120.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVnetEpSyncEpFsmStageDn | 1.3.6.1.4.1.9.9.826.1.26.120.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmStage:dn managed object property |
| STR cfprFabricVnetEpSyncEpFsmStageRn | 1.3.6.1.4.1.9.9.826.1.26.120.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmStage:rn managed object property |
| STR cfprFabricVnetEpSyncEpFsmStageDescrData | 1.3.6.1.4.1.9.9.826.1.26.120.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmStage:descr managed object property |
| DAT cfprFabricVnetEpSyncEpFsmStageLastUpdateTime | 1.3.6.1.4.1.9.9.826.1.26.120.1.5 | DateAndTime | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmStage:lastUpdateTime managed object property |
| CFP cfprFabricVnetEpSyncEpFsmStageName | 1.3.6.1.4.1.9.9.826.1.26.120.1.6 | CfprFabricVnetEpSyncEpFsmStageName | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmStage:name managed object property |
| G32 cfprFabricVnetEpSyncEpFsmStageOrder | 1.3.6.1.4.1.9.9.826.1.26.120.1.7 | Gauge32 | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmStage:order managed object property |
| G32 cfprFabricVnetEpSyncEpFsmStageRetry | 1.3.6.1.4.1.9.9.826.1.26.120.1.8 | Gauge32 | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmStage:retry managed object property |
| CFP cfprFabricVnetEpSyncEpFsmStageStageStatus | 1.3.6.1.4.1.9.9.826.1.26.120.1.9 | CfprFsmFsmStageStatus | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmStage:stageStatus managed object property |
| cfprFabricVnetEpSyncEpFsmTaskTable | 1.3.6.1.4.1.9.9.826.1.26.121 | not-accessible | Cisco Firepower fabric:VnetEpSyncEpFsmTask managed object table | |
| cfprFabricVnetEpSyncEpFsmTaskEntry | 1.3.6.1.4.1.9.9.826.1.26.121.1 | not-accessible | Entry for the cfprFabricVnetEpSyncEpFsmTaskTable table. | |
| CFP cfprFabricVnetEpSyncEpFsmTaskInstanceId | 1.3.6.1.4.1.9.9.826.1.26.121.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVnetEpSyncEpFsmTaskDn | 1.3.6.1.4.1.9.9.826.1.26.121.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmTask:dn managed object property |
| STR cfprFabricVnetEpSyncEpFsmTaskRn | 1.3.6.1.4.1.9.9.826.1.26.121.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmTask:rn managed object property |
| CFP cfprFabricVnetEpSyncEpFsmTaskCompletion | 1.3.6.1.4.1.9.9.826.1.26.121.1.4 | CfprFsmCompletion | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmTask:completion managed object property |
| CFP cfprFabricVnetEpSyncEpFsmTaskFlags | 1.3.6.1.4.1.9.9.826.1.26.121.1.5 | CfprFsmFlags | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmTask:flags managed object property |
| CFP cfprFabricVnetEpSyncEpFsmTaskItem | 1.3.6.1.4.1.9.9.826.1.26.121.1.6 | CfprFabricVnetEpSyncEpFsmTaskItem | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmTask:item managed object property |
| G32 cfprFabricVnetEpSyncEpFsmTaskSeqId | 1.3.6.1.4.1.9.9.826.1.26.121.1.7 | Gauge32 | read-only | Cisco Firepower fabric:VnetEpSyncEpFsmTask:seqId managed object property |
| cfprFabricVsanTable | 1.3.6.1.4.1.9.9.826.1.26.122 | not-accessible | Cisco Firepower fabric:Vsan managed object table | |
| cfprFabricVsanEntry | 1.3.6.1.4.1.9.9.826.1.26.122.1 | not-accessible | Entry for the cfprFabricVsanTable table. | |
| CFP cfprFabricVsanInstanceId | 1.3.6.1.4.1.9.9.826.1.26.122.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVsanDn | 1.3.6.1.4.1.9.9.826.1.26.122.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:Vsan:dn managed object property |
| STR cfprFabricVsanRn | 1.3.6.1.4.1.9.9.826.1.26.122.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:Vsan:rn managed object property |
| CFP cfprFabricVsanDefaultZoning | 1.3.6.1.4.1.9.9.826.1.26.122.1.4 | CfprFabricDefaultZoningState | read-only | Cisco Firepower fabric:Vsan:defaultZoning managed object property |
| STR cfprFabricVsanEpDn | 1.3.6.1.4.1.9.9.826.1.26.122.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:Vsan:epDn managed object property |
| CFP cfprFabricVsanFcZoneSharingMode | 1.3.6.1.4.1.9.9.826.1.26.122.1.6 | CfprFabricFcZoneSharingMode | read-only | Cisco Firepower fabric:Vsan:fcZoneSharingMode managed object property |
| G32 cfprFabricVsanFcoeVlan | 1.3.6.1.4.1.9.9.826.1.26.122.1.7 | Gauge32 | read-only | Cisco Firepower fabric:Vsan:fcoeVlan managed object property |
| UNS cfprFabricVsanFltAggr | 1.3.6.1.4.1.9.9.826.1.26.122.1.8 | Unsigned64 | read-only | Cisco Firepower fabric:Vsan:fltAggr managed object property |
| UNS cfprFabricVsanGlobal | 1.3.6.1.4.1.9.9.826.1.26.122.1.9 | Unsigned64 | read-only | Cisco Firepower fabric:Vsan:global managed object property |
| G32 cfprFabricVsanId | 1.3.6.1.4.1.9.9.826.1.26.122.1.10 | Gauge32 | read-only | Cisco Firepower fabric:Vsan:id managed object property |
| CFP cfprFabricVsanIfRole | 1.3.6.1.4.1.9.9.826.1.26.122.1.11 | CfprFabricVnetEpIfRole | read-only | Cisco Firepower fabric:Vsan:ifRole managed object property |
| CFP cfprFabricVsanIfType | 1.3.6.1.4.1.9.9.826.1.26.122.1.12 | CfprNetworkVnetEpIfType | read-only | Cisco Firepower fabric:Vsan:ifType managed object property |
| UNS cfprFabricVsanLocal | 1.3.6.1.4.1.9.9.826.1.26.122.1.13 | Unsigned64 | read-only | Cisco Firepower fabric:Vsan:local managed object property |
| CFP cfprFabricVsanLocale | 1.3.6.1.4.1.9.9.826.1.26.122.1.14 | CfprFabricVnetEpLocale | read-only | Cisco Firepower fabric:Vsan:locale managed object property |
| STR cfprFabricVsanName | 1.3.6.1.4.1.9.9.826.1.26.122.1.15 | SnmpAdminString | read-only | Cisco Firepower fabric:Vsan:name managed object property |
| CFP cfprFabricVsanOperState | 1.3.6.1.4.1.9.9.826.1.26.122.1.16 | CfprFabricVsanOperState | read-only | Cisco Firepower fabric:Vsan:operState managed object property |
| STR cfprFabricVsanPeerDn | 1.3.6.1.4.1.9.9.826.1.26.122.1.17 | SnmpAdminString | read-only | Cisco Firepower fabric:Vsan:peerDn managed object property |
| CFP cfprFabricVsanPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.122.1.18 | CfprFabricVnetEpPolicyOwner | read-only | Cisco Firepower fabric:Vsan:policyOwner managed object property |
| CFP cfprFabricVsanSwitchId | 1.3.6.1.4.1.9.9.826.1.26.122.1.19 | CfprFabricVsanSwitchId | read-only | Cisco Firepower fabric:Vsan:switchId managed object property |
| CFP cfprFabricVsanTransport | 1.3.6.1.4.1.9.9.826.1.26.122.1.20 | CfprFabricAVsanTransport | read-only | Cisco Firepower fabric:Vsan:transport managed object property |
| CFP cfprFabricVsanType | 1.3.6.1.4.1.9.9.826.1.26.122.1.21 | CfprFabricAVsanType | read-only | Cisco Firepower fabric:Vsan:type managed object property |
| CFP cfprFabricVsanZoningState | 1.3.6.1.4.1.9.9.826.1.26.122.1.22 | CfprFabricZoningState | read-only | Cisco Firepower fabric:Vsan:zoningState managed object property |
| cfprFabricVsanEpTable | 1.3.6.1.4.1.9.9.826.1.26.123 | not-accessible | Cisco Firepower fabric:VsanEp managed object table | |
| cfprFabricVsanEpEntry | 1.3.6.1.4.1.9.9.826.1.26.123.1 | not-accessible | Entry for the cfprFabricVsanEpTable table. | |
| CFP cfprFabricVsanEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.123.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVsanEpDnData | 1.3.6.1.4.1.9.9.826.1.26.123.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:VsanEp:dn managed object property |
| STR cfprFabricVsanEpRn | 1.3.6.1.4.1.9.9.826.1.26.123.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:VsanEp:rn managed object property |
| STR cfprFabricVsanEpEpDn | 1.3.6.1.4.1.9.9.826.1.26.123.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:VsanEp:epDn managed object property |
| G32 cfprFabricVsanEpFcoeVlan | 1.3.6.1.4.1.9.9.826.1.26.123.1.5 | Gauge32 | read-only | Cisco Firepower fabric:VsanEp:fcoeVlan managed object property |
| G32 cfprFabricVsanEpId | 1.3.6.1.4.1.9.9.826.1.26.123.1.6 | Gauge32 | read-only | Cisco Firepower fabric:VsanEp:id managed object property |
| CFP cfprFabricVsanEpIfRole | 1.3.6.1.4.1.9.9.826.1.26.123.1.7 | CfprFabricVnetEpIfRole | read-only | Cisco Firepower fabric:VsanEp:ifRole managed object property |
| CFP cfprFabricVsanEpIfType | 1.3.6.1.4.1.9.9.826.1.26.123.1.8 | CfprNetworkVnetEpIfType | read-only | Cisco Firepower fabric:VsanEp:ifType managed object property |
| CFP cfprFabricVsanEpLocale | 1.3.6.1.4.1.9.9.826.1.26.123.1.9 | CfprFabricVnetEpLocale | read-only | Cisco Firepower fabric:VsanEp:locale managed object property |
| STR cfprFabricVsanEpName | 1.3.6.1.4.1.9.9.826.1.26.123.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:VsanEp:name managed object property |
| CFP cfprFabricVsanEpOperState | 1.3.6.1.4.1.9.9.826.1.26.123.1.11 | CfprFabricVsanOperState | read-only | Cisco Firepower fabric:VsanEp:operState managed object property |
| STR cfprFabricVsanEpPeerDn | 1.3.6.1.4.1.9.9.826.1.26.123.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:VsanEp:peerDn managed object property |
| CFP cfprFabricVsanEpPolicyOwner | 1.3.6.1.4.1.9.9.826.1.26.123.1.13 | CfprFabricVnetEpPolicyOwner | read-only | Cisco Firepower fabric:VsanEp:policyOwner managed object property |
| CFP cfprFabricVsanEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.123.1.14 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:VsanEp:switchId managed object property |
| CFP cfprFabricVsanEpTransport | 1.3.6.1.4.1.9.9.826.1.26.123.1.15 | CfprFabricAVsanTransport | read-only | Cisco Firepower fabric:VsanEp:transport managed object property |
| CFP cfprFabricVsanEpType | 1.3.6.1.4.1.9.9.826.1.26.123.1.16 | CfprFabricAVsanType | read-only | Cisco Firepower fabric:VsanEp:type managed object property |
| CFP cfprFabricVsanEpZoningState | 1.3.6.1.4.1.9.9.826.1.26.123.1.17 | CfprFabricZoningState | read-only | Cisco Firepower fabric:VsanEp:zoningState managed object property |
| cfprFabricVsanMembershipTable | 1.3.6.1.4.1.9.9.826.1.26.124 | not-accessible | Cisco Firepower fabric:VsanMembership managed object table | |
| cfprFabricVsanMembershipEntry | 1.3.6.1.4.1.9.9.826.1.26.124.1 | not-accessible | Entry for the cfprFabricVsanMembershipTable table. | |
| CFP cfprFabricVsanMembershipInstanceId | 1.3.6.1.4.1.9.9.826.1.26.124.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricVsanMembershipDn | 1.3.6.1.4.1.9.9.826.1.26.124.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:VsanMembership:dn managed object property |
| STR cfprFabricVsanMembershipRn | 1.3.6.1.4.1.9.9.826.1.26.124.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:VsanMembership:rn managed object property |
| CFP cfprFabricVsanMembershipMemberStatus | 1.3.6.1.4.1.9.9.826.1.26.124.1.4 | CfprFabricMemberStatus | read-only | Cisco Firepower fabric:VsanMembership:memberStatus managed object property |
| CFP cfprFabricVsanMembershipParentAdminState | 1.3.6.1.4.1.9.9.826.1.26.124.1.5 | CfprFabricAdminState | read-only | Cisco Firepower fabric:VsanMembership:parentAdminState managed object property |
| STR cfprFabricVsanMembershipStateQual | 1.3.6.1.4.1.9.9.826.1.26.124.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:VsanMembership:stateQual managed object property |
| G32 cfprFabricVsanMembershipVsanId | 1.3.6.1.4.1.9.9.826.1.26.124.1.7 | Gauge32 | read-only | Cisco Firepower fabric:VsanMembership:vsanId managed object property |
| cfprFabricZoneIdUniverseTable | 1.3.6.1.4.1.9.9.826.1.26.125 | not-accessible | Cisco Firepower fabric:ZoneIdUniverse managed object table | |
| cfprFabricZoneIdUniverseEntry | 1.3.6.1.4.1.9.9.826.1.26.125.1 | not-accessible | Entry for the cfprFabricZoneIdUniverseTable table. | |
| CFP cfprFabricZoneIdUniverseInstanceId | 1.3.6.1.4.1.9.9.826.1.26.125.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricZoneIdUniverseDn | 1.3.6.1.4.1.9.9.826.1.26.125.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:ZoneIdUniverse:dn managed object property |
| STR cfprFabricZoneIdUniverseRn | 1.3.6.1.4.1.9.9.826.1.26.125.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:ZoneIdUniverse:rn managed object property |
| cfprFabricSspEthMonTable | 1.3.6.1.4.1.9.9.826.1.26.126 | not-accessible | Cisco Firepower fabric:SspEthMon managed object table | |
| cfprFabricSspEthMonEntry | 1.3.6.1.4.1.9.9.826.1.26.126.1 | not-accessible | Entry for the cfprFabricSspEthMonTable table. | |
| CFP cfprFabricSspEthMonInstanceId | 1.3.6.1.4.1.9.9.826.1.26.126.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSspEthMonDn | 1.3.6.1.4.1.9.9.826.1.26.126.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SspEthMon:dn managed object property |
| STR cfprFabricSspEthMonRn | 1.3.6.1.4.1.9.9.826.1.26.126.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMon:rn managed object property |
| CFP cfprFabricSspEthMonAdminState | 1.3.6.1.4.1.9.9.826.1.26.126.1.4 | CfprFabricSspMonAdminState | read-only | Cisco Firepower fabric:SspEthMon:adminState managed object property |
| CFP cfprFabricSspEthMonAppendFlag | 1.3.6.1.4.1.9.9.826.1.26.126.1.5 | CfprFabricSspEthMonAppendFlag | read-only | Cisco Firepower fabric:SspEthMon:appendFlag managed object property |
| STR cfprFabricSspEthMonConfigFailReason | 1.3.6.1.4.1.9.9.826.1.26.126.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMon:configFailReason managed object property |
| CFP cfprFabricSspEthMonDelPcap | 1.3.6.1.4.1.9.9.826.1.26.126.1.7 | CfprFabricSspMonDelPcap | read-only | Cisco Firepower fabric:SspEthMon:delPcap managed object property |
| CFP cfprFabricSspEthMonId | 1.3.6.1.4.1.9.9.826.1.26.126.1.8 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:SspEthMon:id managed object property |
| T/F cfprFabricSspEthMonIsConfigSuccess | 1.3.6.1.4.1.9.9.826.1.26.126.1.9 | TruthValue | read-only | Cisco Firepower fabric:SspEthMon:isConfigSuccess managed object property |
| STR cfprFabricSspEthMonName | 1.3.6.1.4.1.9.9.826.1.26.126.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMon:name managed object property |
| CFP cfprFabricSspEthMonOperState | 1.3.6.1.4.1.9.9.826.1.26.126.1.11 | CfprFabricSspMonOperState | read-only | Cisco Firepower fabric:SspEthMon:operState managed object property |
| CFP cfprFabricSspEthMonOperStateReason | 1.3.6.1.4.1.9.9.826.1.26.126.1.12 | CfprFabricSspMonOperStateReason | read-only | Cisco Firepower fabric:SspEthMon:operStateReason managed object property |
| STR cfprFabricSspEthMonPeerDn | 1.3.6.1.4.1.9.9.826.1.26.126.1.13 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMon:peerDn managed object property |
| G32 cfprFabricSspEthMonSession | 1.3.6.1.4.1.9.9.826.1.26.126.1.14 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMon:session managed object property |
| G32 cfprFabricSspEthMonSessionMemUsage | 1.3.6.1.4.1.9.9.826.1.26.126.1.15 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMon:sessionMemUsage managed object property |
| G32 cfprFabricSspEthMonSourceConfigured | 1.3.6.1.4.1.9.9.826.1.26.126.1.16 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMon:sourceConfigured managed object property |
| CFP cfprFabricSspEthMonDelAllSessEnabledState | 1.3.6.1.4.1.9.9.826.1.26.126.1.17 | CfprFabricSspEthMonDelAllSessEnabledState | read-only | Cisco Firepower fabric:SspEthMon:delAllSessEnabledState managed object property |
| UNS cfprFabricSspEthMonDropCount | 1.3.6.1.4.1.9.9.826.1.26.126.1.18 | Unsigned64 | read-only | Cisco Firepower fabric:SspEthMon:dropCount managed object property |
| STR cfprFabricSspEthMonErrorCode | 1.3.6.1.4.1.9.9.826.1.26.126.1.19 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMon:errorCode managed object property |
| T/F cfprFabricSspEthMonIsConfiguredByAG | 1.3.6.1.4.1.9.9.826.1.26.126.1.20 | TruthValue | read-only | Cisco Firepower fabric:SspEthMon:isConfiguredByAG managed object property |
| STR cfprFabricSspEthMonReBoot | 1.3.6.1.4.1.9.9.826.1.26.126.1.21 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMon:reBoot managed object property |
| G32 cfprFabricSspEthMonSessionPcapSnapLen | 1.3.6.1.4.1.9.9.826.1.26.126.1.22 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMon:sessionPcapSnapLen managed object property |
| cfprFabricSspEthMonFilterEpTable | 1.3.6.1.4.1.9.9.826.1.26.127 | not-accessible | Cisco Firepower fabric:SspEthMonFilterEp managed object table | |
| cfprFabricSspEthMonFilterEpEntry | 1.3.6.1.4.1.9.9.826.1.26.127.1 | not-accessible | Entry for the cfprFabricSspEthMonFilterEpTable table. | |
| CFP cfprFabricSspEthMonFilterEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.127.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSspEthMonFilterEpDn | 1.3.6.1.4.1.9.9.826.1.26.127.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SspEthMonFilterEp:dn managed object property |
| STR cfprFabricSspEthMonFilterEpRn | 1.3.6.1.4.1.9.9.826.1.26.127.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonFilterEp:rn managed object property |
| ADR cfprFabricSspEthMonFilterEpDestIp | 1.3.6.1.4.1.9.9.826.1.26.127.1.4 | InetAddressIPv4 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:destIp managed object property |
| MAC cfprFabricSspEthMonFilterEpDestMAC | 1.3.6.1.4.1.9.9.826.1.26.127.1.5 | MacAddress | read-only | Cisco Firepower fabric:SspEthMonFilterEp:destMAC managed object property |
| G32 cfprFabricSspEthMonFilterEpDestPort | 1.3.6.1.4.1.9.9.826.1.26.127.1.6 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:destPort managed object property |
| G32 cfprFabricSspEthMonFilterEpEthertype | 1.3.6.1.4.1.9.9.826.1.26.127.1.7 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:ethertype managed object property |
| G32 cfprFabricSspEthMonFilterEpIvlan | 1.3.6.1.4.1.9.9.826.1.26.127.1.8 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:ivlan managed object property |
| STR cfprFabricSspEthMonFilterEpNameId | 1.3.6.1.4.1.9.9.826.1.26.127.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonFilterEp:nameId managed object property |
| G32 cfprFabricSspEthMonFilterEpOvlan | 1.3.6.1.4.1.9.9.826.1.26.127.1.10 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:ovlan managed object property |
| G32 cfprFabricSspEthMonFilterEpProtocol | 1.3.6.1.4.1.9.9.826.1.26.127.1.11 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:protocol managed object property |
| ADR cfprFabricSspEthMonFilterEpSrcIp | 1.3.6.1.4.1.9.9.826.1.26.127.1.12 | InetAddressIPv4 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:srcIp managed object property |
| MAC cfprFabricSspEthMonFilterEpSrcMAC | 1.3.6.1.4.1.9.9.826.1.26.127.1.13 | MacAddress | read-only | Cisco Firepower fabric:SspEthMonFilterEp:srcMAC managed object property |
| G32 cfprFabricSspEthMonFilterEpSrcPort | 1.3.6.1.4.1.9.9.826.1.26.127.1.14 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:srcPort managed object property |
| ADR cfprFabricSspEthMonFilterEpDestIpv6 | 1.3.6.1.4.1.9.9.826.1.26.127.1.15 | InetAddressIPv6 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:destIpv6 managed object property |
| G32 cfprFabricSspEthMonFilterEpEcmpId | 1.3.6.1.4.1.9.9.826.1.26.127.1.16 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:ecmpId managed object property |
| ADR cfprFabricSspEthMonFilterEpSrcIpv6 | 1.3.6.1.4.1.9.9.826.1.26.127.1.17 | InetAddressIPv6 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:srcIpv6 managed object property |
| G32 cfprFabricSspEthMonFilterEpSubvlan | 1.3.6.1.4.1.9.9.826.1.26.127.1.18 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:subvlan managed object property |
| G32 cfprFabricSspEthMonFilterEpVifId | 1.3.6.1.4.1.9.9.826.1.26.127.1.19 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonFilterEp:vifId managed object property |
| cfprFabricSspEthMonSrcAppEpTable | 1.3.6.1.4.1.9.9.826.1.26.128 | not-accessible | Cisco Firepower fabric:SspEthMonSrcAppEp managed object table | |
| cfprFabricSspEthMonSrcAppEpEntry | 1.3.6.1.4.1.9.9.826.1.26.128.1 | not-accessible | Entry for the cfprFabricSspEthMonSrcAppEpTable table. | |
| CFP cfprFabricSspEthMonSrcAppEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.128.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSspEthMonSrcAppEpDn | 1.3.6.1.4.1.9.9.826.1.26.128.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:dn managed object property |
| STR cfprFabricSspEthMonSrcAppEpRn | 1.3.6.1.4.1.9.9.826.1.26.128.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:rn managed object property |
| STR cfprFabricSspEthMonSrcAppEpAppName | 1.3.6.1.4.1.9.9.826.1.26.128.1.4 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:appName managed object property |
| STR cfprFabricSspEthMonSrcAppEpFilter | 1.3.6.1.4.1.9.9.826.1.26.128.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:filter managed object property |
| STR cfprFabricSspEthMonSrcAppEpLinkName | 1.3.6.1.4.1.9.9.826.1.26.128.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:linkName managed object property |
| STR cfprFabricSspEthMonSrcAppEpPcapfile | 1.3.6.1.4.1.9.9.826.1.26.128.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:pcapfile managed object property |
| STR cfprFabricSspEthMonSrcAppEpPcapfilename | 1.3.6.1.4.1.9.9.826.1.26.128.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:pcapfilename managed object property |
| G32 cfprFabricSspEthMonSrcAppEpPcapsize | 1.3.6.1.4.1.9.9.826.1.26.128.1.9 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:pcapsize managed object property |
| STR cfprFabricSspEthMonSrcAppEpPortName | 1.3.6.1.4.1.9.9.826.1.26.128.1.10 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:portName managed object property |
| CFP cfprFabricSspEthMonSrcAppEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.128.1.11 | CfprFabricPktCaptureAppSlotId | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:slotId managed object property |
| STR cfprFabricSspEthMonSrcAppEpAppInstance | 1.3.6.1.4.1.9.9.826.1.26.128.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:appInstance managed object property |
| G32 cfprFabricSspEthMonSrcAppEpSubInterface | 1.3.6.1.4.1.9.9.826.1.26.128.1.13 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:subInterface managed object property |
| STR cfprFabricSspEthMonSrcAppEpExternalLduLinkDn | 1.3.6.1.4.1.9.9.826.1.26.128.1.14 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppEp:externalLduLinkDn managed object property |
| cfprFabricSspEthMonSrcAppLinksEpTable | 1.3.6.1.4.1.9.9.826.1.26.129 | not-accessible | Cisco Firepower fabric:SspEthMonSrcAppLinksEp managed object table | |
| cfprFabricSspEthMonSrcAppLinksEpEntry | 1.3.6.1.4.1.9.9.826.1.26.129.1 | not-accessible | Entry for the cfprFabricSspEthMonSrcAppLinksEpTable table. | |
| CFP cfprFabricSspEthMonSrcAppLinksEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.129.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSspEthMonSrcAppLinksEpDn | 1.3.6.1.4.1.9.9.826.1.26.129.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:dn managed object property |
| STR cfprFabricSspEthMonSrcAppLinksEpRn | 1.3.6.1.4.1.9.9.826.1.26.129.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:rn managed object property |
| G32 cfprFabricSspEthMonSrcAppLinksEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.129.1.4 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:chassisId managed object property |
| G32 cfprFabricSspEthMonSrcAppLinksEpEqAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.129.1.5 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:eqAggrPortId managed object property |
| G32 cfprFabricSspEthMonSrcAppLinksEpEqPortId | 1.3.6.1.4.1.9.9.826.1.26.129.1.6 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:eqPortId managed object property |
| G32 cfprFabricSspEthMonSrcAppLinksEpEqSlotId | 1.3.6.1.4.1.9.9.826.1.26.129.1.7 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:eqSlotId managed object property |
| STR cfprFabricSspEthMonSrcAppLinksEpFilter | 1.3.6.1.4.1.9.9.826.1.26.129.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:filter managed object property |
| STR cfprFabricSspEthMonSrcAppLinksEpFilterDn | 1.3.6.1.4.1.9.9.826.1.26.129.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:filterDn managed object property |
| CFP cfprFabricSspEthMonSrcAppLinksEpLifeCycle | 1.3.6.1.4.1.9.9.826.1.26.129.1.10 | CfprSwPktCaptureLifeCycle | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:lifeCycle managed object property |
| STR cfprFabricSspEthMonSrcAppLinksEpName | 1.3.6.1.4.1.9.9.826.1.26.129.1.11 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:name managed object property |
| STR cfprFabricSspEthMonSrcAppLinksEpPcapfile | 1.3.6.1.4.1.9.9.826.1.26.129.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:pcapfile managed object property |
| STR cfprFabricSspEthMonSrcAppLinksEpPcapfilename | 1.3.6.1.4.1.9.9.826.1.26.129.1.13 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:pcapfilename managed object property |
| G32 cfprFabricSspEthMonSrcAppLinksEpPcapsize | 1.3.6.1.4.1.9.9.826.1.26.129.1.14 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:pcapsize managed object property |
| CFP cfprFabricSspEthMonSrcAppLinksEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.129.1.15 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:switchId managed object property |
| G32 cfprFabricSspEthMonSrcAppLinksEpVlan | 1.3.6.1.4.1.9.9.826.1.26.129.1.16 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:vlan managed object property |
| G32 cfprFabricSspEthMonSrcAppLinksEpVifId | 1.3.6.1.4.1.9.9.826.1.26.129.1.17 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcAppLinksEp:vifId managed object property |
| cfprFabricSspEthMonSrcPhyAggrEpTable | 1.3.6.1.4.1.9.9.826.1.26.130 | not-accessible | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp managed object table | |
| cfprFabricSspEthMonSrcPhyAggrEpEntry | 1.3.6.1.4.1.9.9.826.1.26.130.1 | not-accessible | Entry for the cfprFabricSspEthMonSrcPhyAggrEpTable table. | |
| CFP cfprFabricSspEthMonSrcPhyAggrEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.130.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSspEthMonSrcPhyAggrEpDn | 1.3.6.1.4.1.9.9.826.1.26.130.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:dn managed object property |
| STR cfprFabricSspEthMonSrcPhyAggrEpRn | 1.3.6.1.4.1.9.9.826.1.26.130.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:rn managed object property |
| G32 cfprFabricSspEthMonSrcPhyAggrEpAggrPortId | 1.3.6.1.4.1.9.9.826.1.26.130.1.4 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:aggrPortId managed object property |
| G32 cfprFabricSspEthMonSrcPhyAggrEpBreakoutPortId | 1.3.6.1.4.1.9.9.826.1.26.130.1.5 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:breakoutPortId managed object property |
| G32 cfprFabricSspEthMonSrcPhyAggrEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.130.1.6 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:chassisId managed object property |
| STR cfprFabricSspEthMonSrcPhyAggrEpFilter | 1.3.6.1.4.1.9.9.826.1.26.130.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:filter managed object property |
| STR cfprFabricSspEthMonSrcPhyAggrEpPcapfile | 1.3.6.1.4.1.9.9.826.1.26.130.1.8 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:pcapfile managed object property |
| STR cfprFabricSspEthMonSrcPhyAggrEpPcapfilename | 1.3.6.1.4.1.9.9.826.1.26.130.1.9 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:pcapfilename managed object property |
| G32 cfprFabricSspEthMonSrcPhyAggrEpPcapsize | 1.3.6.1.4.1.9.9.826.1.26.130.1.10 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:pcapsize managed object property |
| G32 cfprFabricSspEthMonSrcPhyAggrEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.130.1.11 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:slotId managed object property |
| CFP cfprFabricSspEthMonSrcPhyAggrEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.130.1.12 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:switchId managed object property |
| STR cfprFabricSspEthMonSrcPhyAggrEpAppInstance | 1.3.6.1.4.1.9.9.826.1.26.130.1.13 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:appInstance managed object property |
| STR cfprFabricSspEthMonSrcPhyAggrEpAppName | 1.3.6.1.4.1.9.9.826.1.26.130.1.14 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:appName managed object property |
| G32 cfprFabricSspEthMonSrcPhyAggrEpSubInterface | 1.3.6.1.4.1.9.9.826.1.26.130.1.15 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:subInterface managed object property |
| G32 cfprFabricSspEthMonSrcPhyAggrEpEcmpId | 1.3.6.1.4.1.9.9.826.1.26.130.1.16 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:ecmpId managed object property |
| cfprFabricSspEthMonSrcPhyEpTable | 1.3.6.1.4.1.9.9.826.1.26.131 | not-accessible | Cisco Firepower fabric:SspEthMonSrcPhyEp managed object table | |
| cfprFabricSspEthMonSrcPhyEpEntry | 1.3.6.1.4.1.9.9.826.1.26.131.1 | not-accessible | Entry for the cfprFabricSspEthMonSrcPhyEpTable table. | |
| CFP cfprFabricSspEthMonSrcPhyEpInstanceId | 1.3.6.1.4.1.9.9.826.1.26.131.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSspEthMonSrcPhyEpDn | 1.3.6.1.4.1.9.9.826.1.26.131.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:dn managed object property |
| STR cfprFabricSspEthMonSrcPhyEpRn | 1.3.6.1.4.1.9.9.826.1.26.131.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:rn managed object property |
| G32 cfprFabricSspEthMonSrcPhyEpChassisId | 1.3.6.1.4.1.9.9.826.1.26.131.1.4 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:chassisId managed object property |
| STR cfprFabricSspEthMonSrcPhyEpFilter | 1.3.6.1.4.1.9.9.826.1.26.131.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:filter managed object property |
| STR cfprFabricSspEthMonSrcPhyEpPcapfile | 1.3.6.1.4.1.9.9.826.1.26.131.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:pcapfile managed object property |
| STR cfprFabricSspEthMonSrcPhyEpPcapfilename | 1.3.6.1.4.1.9.9.826.1.26.131.1.7 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:pcapfilename managed object property |
| G32 cfprFabricSspEthMonSrcPhyEpPcapsize | 1.3.6.1.4.1.9.9.826.1.26.131.1.8 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:pcapsize managed object property |
| G32 cfprFabricSspEthMonSrcPhyEpPortId | 1.3.6.1.4.1.9.9.826.1.26.131.1.9 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:portId managed object property |
| G32 cfprFabricSspEthMonSrcPhyEpSlotId | 1.3.6.1.4.1.9.9.826.1.26.131.1.10 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:slotId managed object property |
| CFP cfprFabricSspEthMonSrcPhyEpSwitchId | 1.3.6.1.4.1.9.9.826.1.26.131.1.11 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:switchId managed object property |
| STR cfprFabricSspEthMonSrcPhyEpAppInstance | 1.3.6.1.4.1.9.9.826.1.26.131.1.12 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:appInstance managed object property |
| STR cfprFabricSspEthMonSrcPhyEpAppName | 1.3.6.1.4.1.9.9.826.1.26.131.1.13 | SnmpAdminString | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:appName managed object property |
| G32 cfprFabricSspEthMonSrcPhyEpSubInterface | 1.3.6.1.4.1.9.9.826.1.26.131.1.14 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:subInterface managed object property |
| G32 cfprFabricSspEthMonSrcPhyEpEcmpId | 1.3.6.1.4.1.9.9.826.1.26.131.1.15 | Gauge32 | read-only | Cisco Firepower fabric:SspEthMonSrcPhyEp:ecmpId managed object property |
| cfprFabricSspLanMonCloudTable | 1.3.6.1.4.1.9.9.826.1.26.132 | not-accessible | Cisco Firepower fabric:SspLanMonCloud managed object table | |
| cfprFabricSspLanMonCloudEntry | 1.3.6.1.4.1.9.9.826.1.26.132.1 | not-accessible | Entry for the cfprFabricSspLanMonCloudTable table. | |
| CFP cfprFabricSspLanMonCloudInstanceId | 1.3.6.1.4.1.9.9.826.1.26.132.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSspLanMonCloudDn | 1.3.6.1.4.1.9.9.826.1.26.132.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SspLanMonCloud:dn managed object property |
| STR cfprFabricSspLanMonCloudRn | 1.3.6.1.4.1.9.9.826.1.26.132.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SspLanMonCloud:rn managed object property |
| CFP cfprFabricSspLanMonCloudMode | 1.3.6.1.4.1.9.9.826.1.26.132.1.4 | CfprFabricSwitchingMode | read-only | Cisco Firepower fabric:SspLanMonCloud:mode managed object property |
| CFP cfprFabricSspLanMonCloudDelAllSess | 1.3.6.1.4.1.9.9.826.1.26.132.1.5 | CfprFabricSspLanMonCloudDelAllSess | read-only | Cisco Firepower fabric:SspLanMonCloud:delAllSess managed object property |
| cfprFabricInnerVlanMgrTable | 1.3.6.1.4.1.9.9.826.1.26.133 | not-accessible | Cisco Firepower fabric:InnerVlanMgr managed object table | |
| cfprFabricInnerVlanMgrEntry | 1.3.6.1.4.1.9.9.826.1.26.133.1 | not-accessible | Entry for the cfprFabricInnerVlanMgrTable table. | |
| CFP cfprFabricInnerVlanMgrInstanceId | 1.3.6.1.4.1.9.9.826.1.26.133.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricInnerVlanMgrDn | 1.3.6.1.4.1.9.9.826.1.26.133.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:InnerVlanMgr:dn managed object property |
| STR cfprFabricInnerVlanMgrRn | 1.3.6.1.4.1.9.9.826.1.26.133.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:InnerVlanMgr:rn managed object property |
| UNS cfprFabricInnerVlanMgrFltAggr | 1.3.6.1.4.1.9.9.826.1.26.133.1.4 | Unsigned64 | read-only | Cisco Firepower fabric:InnerVlanMgr:fltAggr managed object property |
| CFP cfprFabricInnerVlanMgrId | 1.3.6.1.4.1.9.9.826.1.26.133.1.5 | CfprNetworkSwitchId | read-only | Cisco Firepower fabric:InnerVlanMgr:id managed object property |
| cfprFabricSubIfTable | 1.3.6.1.4.1.9.9.826.1.26.134 | not-accessible | Cisco Firepower fabric:SubIf managed object table | |
| cfprFabricSubIfEntry | 1.3.6.1.4.1.9.9.826.1.26.134.1 | not-accessible | Entry for the cfprFabricSubIfTable table. | |
| CFP cfprFabricSubIfInstanceId | 1.3.6.1.4.1.9.9.826.1.26.134.1.1 | CfprManagedObjectId | not-accessible | Instance identifier of the managed object. |
| CFP cfprFabricSubIfDn | 1.3.6.1.4.1.9.9.826.1.26.134.1.2 | CfprManagedObjectDn | read-only | Cisco Firepower fabric:SubIf:dn managed object property |
| STR cfprFabricSubIfRn | 1.3.6.1.4.1.9.9.826.1.26.134.1.3 | SnmpAdminString | read-only | Cisco Firepower fabric:SubIf:rn managed object property |
| T/F cfprFabricSubIfAllowSharing | 1.3.6.1.4.1.9.9.826.1.26.134.1.4 | TruthValue | read-only | Cisco Firepower fabric:SubIf:allowSharing managed object property |
| STR cfprFabricSubIfDescr | 1.3.6.1.4.1.9.9.826.1.26.134.1.5 | SnmpAdminString | read-only | Cisco Firepower fabric:SubIf:descr managed object property |
| STR cfprFabricSubIfIfName | 1.3.6.1.4.1.9.9.826.1.26.134.1.6 | SnmpAdminString | read-only | Cisco Firepower fabric:SubIf:ifName managed object property |
| CFP cfprFabricSubIfSsaPortType | 1.3.6.1.4.1.9.9.826.1.26.134.1.7 | CfprFabricSSASubPortType | read-only | Cisco Firepower fabric:SubIf:ssaPortType managed object property |
| G32 cfprFabricSubIfSubId | 1.3.6.1.4.1.9.9.826.1.26.134.1.8 | Gauge32 | read-only | Cisco Firepower fabric:SubIf:subId managed object property |
| INT cfprFabricSubIfVlanId | 1.3.6.1.4.1.9.9.826.1.26.134.1.9 | INTEGER | read-only | Cisco Firepower fabric:SubIf:vlanId managed object property |
RFC description
A Cisco SNMP MIB supporting monitoring of Cisco Firepower fabric components and infrastructure on chassis-based platforms like Firepower 4100, 9300, and Secure Firewall appliances.
Start monitoring Cisco UCS/Firepower fabric interconnects with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.