All MIBs › CIENA-CES-CHASSIS-MIB
Organization: Ciena Corp.
Last Updated: 2018-10-17
Category: Hardware and Environment, Vendor: Ciena
Description: Monitors chassis hardware components including slots, fans, and power supplies on Ciena CES switches.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CIENA-CES-CHASSIS-MIB?
CIENA-CES-CHASSIS-MIB is a Ciena enterprise MIB for the CES (Carrier Ethernet Switch) product line, defining chassis-level hardware configuration objects and the notifications associated with chassis events. It exposes chassis component health data, including a process health table for monitoring the operational state of internal software processes. Administrators use it to monitor both hardware status (chassis components such as slots, fans, and power supplies per the module's stated scope) and software process health, helping detect a failed process, an overheating condition, or a power/fan fault that could lead to an outage. It likely complements the standard IETF Entity MIB for physical inventory representation, though implemented as a Ciena proprietary extension for chassis-specific alarms. It is deployed on Ciena CES carrier Ethernet switches used by service providers for Carrier Ethernet access and aggregation. Network engineers evaluating or troubleshooting this functionality can download the CIENA-CES-CHASSIS-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in CIENA-CES-CHASSIS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Ciena CES (Carrier Ethernet Switch) chassis
Monitoring Examples
An admin would poll cienaCesChassisProcessHealthTable to check the operational status of internal software processes running on the CES chassis, with a process reporting a failed or degraded state indicating a software fault that may require a restart or escalation. Combined with the chassis's broader fan and power supply status objects (per the module's stated scope), this table lets an operator distinguish between a hardware environmental fault and a software process crash when diagnosing a chassis alarm.
What Can Be Monitored
- internal process health/status
- fan status
- power supply status
- chassis component/slot state
This MIB depends on
Related MIBs
Imported Objects
From CIENA-CES-MODULE-MIB
| TceHealthCategory | |
| TceHealthStatus |
From CIENA-GLOBAL-MIB
| cienaGlobalSeverity | OBJECT-TYPE |
From CIENA-SMI
| cienaCesConfig | OBJECT-IDENTITY |
| cienaCesNotifications | OBJECT-IDENTITY |
From SNMPv2-CONF
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| MacAddress | |
| TruthValue |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| chassisFanGroup | 1.3.6.1.4.1.1271.2.1.5.2.2.4 | A collection of objects providing information about chassis fans. | ||
| chassisFanTempGroup | 1.3.6.1.4.1.1271.2.1.5.2.2.6 | A collection of objects providing information about chassis fan temperature. | ||
| chassisFanTrayGroup | 1.3.6.1.4.1.1271.2.1.5.2.2.5 | A collection of objects providing information about chassis fans tray. | ||
| chassisGlobalGroup | 1.3.6.1.4.1.1271.2.1.5.2.2.1 | A collection of objects providing information about chassis global attributes. | ||
| chassisHealthGroup | 1.3.6.1.4.1.1271.2.1.5.2.2.8 | A collection of objects providing information about chassis health attributes. | ||
| chassisIomNotifGroup | 1.3.6.1.4.1.1271.2.1.5.2.2.10 | A collection of notifications that provide information about changes related to the IOM. | ||
| chassisIomStateGroup | 1.3.6.1.4.1.1271.2.1.5.2.2.9 | A collection of objects providing information about the IOM. | ||
| chassisNotifGroup | 1.3.6.1.4.1.1271.2.1.5.2.2.7 | A collection of objects providing information about chassis notifications. | ||
| chassisPlatformGroup | 1.3.6.1.4.1.1271.2.1.5.2.2.2 | A collection of objects providing information about chassis platform attributes. | ||
| chassisPowerSupplyGroup | 1.3.6.1.4.1.1271.2.1.5.2.2.3 | A collection of objects providing information about chassis power supply attributes. | ||
| cienaCesChassis | 1.3.6.1.4.1.1271.2.1.5.1.2.1 | |||
| I32 cienaCesChassisAccessFlowsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.22 | Integer32 | read-only | This object indicates the maximum number of Access Flows supported on the chassis. |
| I32 cienaCesChassisAggPortsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.12 | Integer32 | read-only | This object indicates the maximum aggregated ports supported on this chassis. |
| NTF cienaCesChassisAirFilterServiceNotification | 1.3.6.1.4.1.1271.2.2.4.0.26 | This notification is generated when the air filter service interval is reached. | ||
| NTF cienaCesChassisAlarmCutoffNotification | 1.3.6.1.4.1.1271.2.2.4.0.27 | A cienaCesChassisAlarmCutoffNotification is sent if: 1) The alarm cutoff button on either CM is pushed. 2) The CLI alarm cutoff command is issued. 3) The SNMP alarm cutoff command is issued. To enable the device to send this trap: cienaCesChassisAlarmCutoffTrapState needs to be set to enabled. | ||
| INT cienaCesChassisAlarmCutoffOrigin | 1.3.6.1.4.1.1271.2.1.5.1.1.12 | INTEGER | accessible-for-notify | This object indicates the origin of the alarm cutoff command included in the cienaCesChassisAlarmCutoffNotification. |
| U32 cienaCesChassisControlPlaneHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.7.1.4 | Unsigned32 | read-only | Current value of the control backplane item for the slot being monitored. |
| cienaCesChassisControlPlaneHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.7.1 | not-accessible | An entry in the cienaCesChassisControlPlaneHealthTable. | |
| U32 cienaCesChassisControlPlaneHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.7.1.5 | Unsigned32 | read-only | The maximum recorded value of the control plane item for the slot being monitored. |
| U32 cienaCesChassisControlPlaneHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.7.1.6 | Unsigned32 | read-only | The maximum possible value for the control plane item. |
| U32 cienaCesChassisControlPlaneHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.7.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisControlPlaneHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.7.1.3 | TceHealthStatus | read-only | Status of the control backplane item for the slot being monitored. |
| INT cienaCesChassisControlPlaneHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.7.1.1 | INTEGER | not-accessible | The sub-category of the control backplane item being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisControlPlaneHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.7 | not-accessible | Table listing the health information of control plane resources. | |
| U32 cienaCesChassisCPUHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.5.1.4 | Unsigned32 | read-only | Current value of the cpu utilization for the slot being monitored. |
| cienaCesChassisCPUHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.5.1 | not-accessible | An entry in the cienaCesChassisCPUHealthTable. | |
| U32 cienaCesChassisCPUHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.5.1.5 | Unsigned32 | read-only | The maximum recorded cpu utilization value for the slot being monitored. |
| U32 cienaCesChassisCPUHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.5.1.6 | Unsigned32 | read-only | The maximum possible value of cpu utilization. |
| U32 cienaCesChassisCPUHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.5.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisCPUHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.5.1.3 | TceHealthStatus | read-only | Health state of the cpu sub-category being monitored. |
| INT cienaCesChassisCPUHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.5.1.1 | INTEGER | not-accessible | CPU sub-category being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisCPUHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.5 | not-accessible | Table listing the health information of CPU resources. | |
| I32 cienaCesChassisCPUSubIntfcsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.23 | Integer32 | read-only | This object indicates the maximum number of CPU sub interfaces supported on the chassis. |
| cienaCesChassisDatapathHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.6.1 | not-accessible | An entry in the cienaCesChassisDatapathHealthTable. | |
| U32 cienaCesChassisDatapathHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.6.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisDatapathHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.6.1.3 | TceHealthStatus | read-only | Status of the data-path for the slot being monitored. |
| INT cienaCesChassisDatapathHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.6.1.1 | INTEGER | not-accessible | The sub-category of the health-item being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisDatapathHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.6 | not-accessible | Table listing the health information of datapath resources. | |
| INT cienaCesChassisDcPower | 1.3.6.1.4.1.1271.2.1.5.1.2.2.9 | INTEGER | read-only | This object indicates if DC power is supported for this chassis or not. |
| STR cienaCesChassisDeviceId | 1.3.6.1.4.1.1271.2.1.5.1.1.2 | DisplayString | read-only | This object indicates the chassis device ID. |
| U32 cienaCesChassisDiskHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.12.1.4 | Unsigned32 | read-only | Current value of disk sub-category used for the slot. |
| cienaCesChassisDiskHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.12.1 | not-accessible | An entry in the cienaCesChassisDiskHealthTable. | |
| U32 cienaCesChassisDiskHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.12.1.5 | Unsigned32 | read-only | The maximum recorded value of disk sub-category used by the slot. |
| U32 cienaCesChassisDiskHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.12.1.6 | Unsigned32 | read-only | The maximum size of the disk sub-category. |
| U32 cienaCesChassisDiskHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.12.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisDiskHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.12.1.3 | TceHealthStatus | read-only | Disk sub-category utilization state of the slot. |
| INT cienaCesChassisDiskHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.12.1.1 | INTEGER | not-accessible | The sub-category of the health-item being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisDiskHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.12 | not-accessible | Table listing the health information of disk resources. | |
| NTF cienaCesChassisDyingGaspNotification | 1.3.6.1.4.1.1271.2.2.4.0.28 | This notification is sent when the system losses power | ||
| cienaCesChassisFabricHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.8.1 | not-accessible | An entry in the cienaCesChassisFabricHealthTable. | |
| U32 cienaCesChassisFabricHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.8.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisFabricHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.8.1.4 | TceHealthStatus | read-only | Fabric state of the slot. |
| INT cienaCesChassisFabricHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.8.1.1 | INTEGER | not-accessible | The sub-category of the fabric being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisFabricHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.8 | not-accessible | Table listing the health information of fabric resources. | |
| I32 cienaCesChassisFanAvgSpeed | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1.1.4 | Integer32 | read-only | The average speed of the fan in RPM unit. The average is calculated on a continuous basis from system startup. |
| U32 cienaCesChassisFanChassisIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1.1.10 | Unsigned32 | read-only | This object represents the chassis index. |
| I32 cienaCesChassisFanCurrentSpeed | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1.1.5 | Integer32 | read-only | The current speed of the fan in RPM. |
| cienaCesChassisFanEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1.1 | not-accessible | An entry in the fan module Table providing objects for a fan module. | |
| NTF cienaCesChassisFanHiTempNotification | 1.3.6.1.4.1.1271.2.2.4.0.3 | A cienaCesChassisFanTempNotification is sent if the cienaCesChassisFanTemp is changed to high. To enable the device to send this trap: - cienaCesChassisAllFanTempTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| I32 cienaCesChassisFanIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1.1.2 | Integer32 | not-accessible | This object identifies a fan in the fan tray and is a unique index in the table. |
| NTF cienaCesChassisFanLoTempNotification | 1.3.6.1.4.1.1271.2.2.4.0.5 | A cienaCesChassisFanTempNotification is sent if the cienaCesChassisFanTemp is changed to low. To enable the device to send this trap: - cienaCesChassisAllFanTempTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| I32 cienaCesChassisFanMinSpeed | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1.1.6 | Integer32 | read-only | The minimum speed of the fan in RPM. |
| cienaCesChassisFanModule | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2 | |||
| cienaCesChassisFanModuleTemp | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3 | |||
| STR cienaCesChassisFanName | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1.1.9 | DisplayString | read-only | This object identifies a fan name. |
| NTF cienaCesChassisFanNormalTempNotification | 1.3.6.1.4.1.1271.2.2.4.0.4 | A cienaCesChassisFanTempNotification is sent if the cienaCesChassisFanTemp is changed to normal. To enable the device to send this trap: - cienaCesChassisAllFanTempTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| I32 cienaCesChassisFanNotifIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1.1.8 | Integer32 | accessible-for-notify | This object identifies a fan in the fan tray and is a unique index used in the definition of fan traps. |
| U32 cienaCesChassisFanRPMHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.20.1.4 | Unsigned32 | read-only | Current speed value of the fan being monitored. |
| cienaCesChassisFanRPMHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.20.1 | not-accessible | An entry in the cienaCesChassisFanRPMHealthTable. | |
| U32 cienaCesChassisFanRPMHealthMinMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.20.1.5 | Unsigned32 | read-only | For rows with corresponding cienaCesChassisFanRPMHealthSubCategory index of maxSpeed, this object represents the maximum recorded speed of the fan indexed by cienaCesChassisFanRPMHealthOriginIndex. For rows with corresponding cienaCesChassisFanRPMHealthSubCategory index of minSpeed, this object represents the minimum recorded speed of the fan indexed by cienaCesChassisFanRPMHealthOriginIndex. |
| U32 cienaCesChassisFanRPMHealthMinThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.20.1.6 | Unsigned32 | read-only | For rows with corresponding cienaCesChassisFanRPMHealthSubCategory index of maxSpeed, this object represents the maximum speed at which the fan indexed by cienaCesChassisFanRPMHealthOriginIndex can be operated while maintaining a normal health state. For rows with corresponding cienaCesChassisFanRPMHealthSubCategory index of minSpeed, this object represents the minimum speed at which the fan indexed by cienaCesChassisFanRPMHealthOriginIndex can be operated while maintaining a normal health state. |
| U32 cienaCesChassisFanRPMHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.20.1.2 | Unsigned32 | not-accessible | Index of the fan being monitored. |
| TCE cienaCesChassisFanRPMHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.20.1.3 | TceHealthStatus | read-only | Health state of the fan speed being monitored. |
| INT cienaCesChassisFanRPMHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.20.1.1 | INTEGER | not-accessible | The sub-category of the fan RPM item being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisFanRPMHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.20 | not-accessible | Table listing the health information of fan RPM resources. | |
| INT cienaCesChassisFanSamplesHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.19.1.4 | INTEGER | read-only | Current measurement of fan samples. |
| cienaCesChassisFanSamplesHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.19.1 | not-accessible | An entry in the cienaCesChassisFanSamplesHealthTable. | |
| INT cienaCesChassisFanSamplesHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.19.1.5 | INTEGER | read-only | Maximum measurement of fan samples. |
| U32 cienaCesChassisFanSamplesHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.19.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisFanSamplesHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.19.1.3 | TceHealthStatus | read-only | fan samples state of the slot. |
| INT cienaCesChassisFanSamplesHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.19.1.1 | INTEGER | not-accessible | The sub-category of the fan samples being monitored. - 'none' is an enumeration placeholder - 'invalid' indicates the number of invalid sensor reads if the 'cienaCesChassisFanSamplesHealthCurrMeasurement' associated with this instance is a huge value ,it means something is broken. |
| cienaCesChassisFanSamplesHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.19 | not-accessible | Table listing the health information of fan samples. | |
| U32 cienaCesChassisFanShelfIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1.1.11 | Unsigned32 | read-only | This object represents the chassis shelf index. |
| NTF cienaCesChassisFanSpeedMinThresholdNotification | 1.3.6.1.4.1.1271.2.2.4.0.7 | A cienaCesChassisFanSpeedMinThresholdNotification is sent if the fan speed drops to minimum threshold. To enable the device to send this trap: - cienaCesChassisAllFanTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| cienaCesChassisFanSpeedMismatchHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.17.1 | not-accessible | An entry in the cienaCesChassisFanSpeedMisMatchHealthTable. | |
| U32 cienaCesChassisFanSpeedMismatchHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.17.1.2 | Unsigned32 | not-accessible | Index of the fan being monitored. |
| TCE cienaCesChassisFanSpeedMismatchHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.17.1.3 | TceHealthStatus | read-only | Health Status of the fan being monitored. |
| INT cienaCesChassisFanSpeedMismatchHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.17.1.1 | INTEGER | not-accessible | The sub-category of the fan speed mismatch monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisFanSpeedMismatchHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.17 | not-accessible | Table listing the health information of fan speed mismatch count. | |
| NTF cienaCesChassisFanSpeedNormalRangeNotification | 1.3.6.1.4.1.1271.2.2.4.0.8 | A cienaCesChassisFanSpeedNormalRangeNotification is sent if the fan speed returns to normal value. To enable the device to send this trap: - cienaCesChassisAllFanTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| INT cienaCesChassisFanStatus | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1.1.3 | INTEGER | read-only | Denotes the fan module status as follows: 'ok' means fan is operational, 'pending' means fan is installed but statistics are not yet available, 'rpm_warning' means fan is not working. 'uninstalled' means fan not found. |
| cienaCesChassisFanTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1 | not-accessible | A list of fan module entries. | |
| I32 cienaCesChassisFanTemp | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.4 | Integer32 | read-only | This object indicates the current chassis fan temperature. |
| U32 cienaCesChassisFanTempChassisIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.12 | Unsigned32 | read-only | This object represents the chassis index. |
| STR cienaCesChassisFanTempDesc | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.3 | DisplayString | read-only | This object indicates the description of the fan temperature sensor. |
| cienaCesChassisFanTempEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1 | not-accessible | An entry in the fan temperature module table providing objects for a fan module. | |
| U32 cienaCesChassisFanTempHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1.4 | Unsigned32 | read-only | Current temperature of fan for the temperature sensor being monitored. |
| cienaCesChassisFanTempHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1 | not-accessible | An entry in the cienaCesChassisHealthFanTempTable. | |
| U32 cienaCesChassisFanTempHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1.6 | Unsigned32 | read-only | The minimum recorded temperature for the fan for the temperature sensor being monitored. |
| U32 cienaCesChassisFanTempHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1.8 | Unsigned32 | read-only | The maximum operational temperature for the fan temperature sensor. |
| U32 cienaCesChassisFanTempHealthMinMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1.5 | Unsigned32 | read-only | The minimum recorded temperature for the fan for the temperature sensor being monitored. |
| U32 cienaCesChassisFanTempHealthMinThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1.7 | Unsigned32 | read-only | The minimum operational temperature for the fan temperature sensor. |
| U32 cienaCesChassisFanTempHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1.2 | Unsigned32 | not-accessible | Index of the temperature sensor being monitored. |
| TCE cienaCesChassisFanTempHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1.3 | TceHealthStatus | read-only | Health state of the fan temperature sub-category for the temperature sensor being monitored. |
| INT cienaCesChassisFanTempHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1.1 | INTEGER | not-accessible | The sub-category of the fan temperature being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisFanTempHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18 | not-accessible | Table listing the health information of fan temperature resources. | |
| I32 cienaCesChassisFanTempHigh | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.5 | Integer32 | read-only | This object indicates the highest temperature this chassis fan reached so far. |
| I32 cienaCesChassisFanTempHiThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.8 | Integer32 | read-only | This object indicates the high threshold value for the fan temperature sensor. |
| I32 cienaCesChassisFanTempId | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.2 | Integer32 | not-accessible | This object indicates the unique index in the table. |
| I32 cienaCesChassisFanTempLoThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.7 | Integer32 | read-only | This object indicates the low threshold value for the fan temperature sensor. |
| I32 cienaCesChassisFanTempLow | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.6 | Integer32 | read-only | This object indicates the lowest temperature this chassis fan reached so far. |
| STR cienaCesChassisFanTempName | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.11 | DisplayString | read-only | This object indicates the fan temperature sensor name. |
| I32 cienaCesChassisFanTempNotifId | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.10 | Integer32 | accessible-for-notify | This object indicates the unique index used in fan temperature trap definition. |
| U32 cienaCesChassisFanTempShelfIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.13 | Unsigned32 | read-only | This object represents the chassis shelf index. |
| cienaCesChassisFanTempTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2 | not-accessible | A list of fan temperature module entries. | |
| I32 cienaCesChassisFanTempTrayIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.1 | Integer32 | not-accessible | This object indicates the unique index in the table. |
| I32 cienaCesChassisFanTempTrayNotifIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.3.2.1.9 | Integer32 | accessible-for-notify | This object indicates the unique index used in fan temperature trap definition. |
| U32 cienaCesChassisFanTrayChassisIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.2.1.6 | Unsigned32 | read-only | This object represents the chassis index. |
| cienaCesChassisFanTrayEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.2.1 | not-accessible | An entry in the fan tray module table providing objects related to fan tray. | |
| cienaCesChassisFanTrayHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.15.1 | not-accessible | An entry in the cienaCesChassisFanTrayHealthTable. | |
| U32 cienaCesChassisFanTrayHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.15.1.2 | Unsigned32 | not-accessible | Index of the fan-tray being monitored. |
| TCE cienaCesChassisFanTrayHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.15.1.3 | TceHealthStatus | read-only | Health Status of the fan-tray being monitored. |
| INT cienaCesChassisFanTrayHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.15.1.1 | INTEGER | not-accessible | The sub-category of the fan tray being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisFanTrayHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.15 | not-accessible | Table listing the health information of fan tray resources. | |
| I32 cienaCesChassisFanTrayIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1.1.1 | Integer32 | not-accessible | This object indicates the fan tray and also represents the unique index in the table. |
| NTF cienaCesChassisFanTrayInsertNotification | 1.3.6.1.4.1.1271.2.2.4.0.10 | This notification is sent whenever a fan tray is inserted in the chassis. To enable the device to send this trap: - cienaCesChassisAllFanTrayTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| INT cienaCesChassisFanTrayMode | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.2.1.3 | INTEGER | read-only | This object indicates the operational mode of the fan tray. |
| STR cienaCesChassisFanTrayName | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.2.1.5 | DisplayString | read-only | This object indicates the fan tray name. |
| I32 cienaCesChassisFanTrayNotifIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.1.1.7 | Integer32 | accessible-for-notify | This object indicates the fan tray and also represents the unique index used in the definition of fan traps. |
| I32 cienaCesChassisFanTrayNumFans | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.2.1.4 | Integer32 | read-only | This object indicates the number of fans on the tray. |
| NTF cienaCesChassisFanTrayRemoveNotification | 1.3.6.1.4.1.1271.2.2.4.0.9 | This notification is sent whenever a fan tray is removed from the chassis. To enable the device to send this trap: - cienaCesChassisAllFanTrayTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| STR cienaCesChassisFanTraySerialNumber | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.2.1.9 | DisplayString | read-only | This object indicates the fan tray serial number. |
| U32 cienaCesChassisFanTrayShelfIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.2.1.7 | Unsigned32 | read-only | This object represents the chassis shelf index. |
| U32 cienaCesChassisFanTraySlotIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.2.1.8 | Unsigned32 | read-only | This object represents the fan tray chassis slot index. |
| INT cienaCesChassisFanTraySpeedMismatchHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.16.1.4 | INTEGER | read-only | Current measurement of the fan-tray mismatch speed. |
| cienaCesChassisFanTraySpeedMismatchHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.16.1 | not-accessible | An entry in the cienaCesChassisFanTraySpeedMisMatchHealthTable. | |
| INT cienaCesChassisFanTraySpeedMismatchHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.16.1.5 | INTEGER | read-only | Maximum measurement of the fan-tray mismatch speed. |
| INT cienaCesChassisFanTraySpeedMismatchHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.16.1.6 | INTEGER | read-only | Maximum measurement threshold of the fan-tray mismatch speed. |
| U32 cienaCesChassisFanTraySpeedMismatchHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.16.1.2 | Unsigned32 | not-accessible | Index of the fan-tray being monitored. |
| TCE cienaCesChassisFanTraySpeedMismatchHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.16.1.3 | TceHealthStatus | read-only | Health Status of the fan-tray being monitored. |
| INT cienaCesChassisFanTraySpeedMismatchHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.16.1.1 | INTEGER | not-accessible | The sub-category of the fan tray speed mismatch monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisFanTraySpeedMismatchHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.16 | not-accessible | Table listing the health information of fan tray speed mismatch count. | |
| INT cienaCesChassisFanTrayStatus | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.2.1.1 | INTEGER | read-only | This object indicates the status of the fan tray. |
| NTF cienaCesChassisFanTrayStatusFaultedNotification | 1.3.6.1.4.1.1271.2.2.4.0.11 | This notification is sent whenever the fan tray status changes to one of the following: - pending(2), rpm-warning(3), uninstalled(4), unknown(99) To enable the device to send this trap: - cienaCesChassisAllFanTrayTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| NTF cienaCesChassisFanTrayStatusOkNotification | 1.3.6.1.4.1.1271.2.2.4.0.12 | This notification is sent whenever the fan tray status changes to ok(1). To enable the device to send this trap: - cienaCesChassisAllFanTrayTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| cienaCesChassisFanTrayTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.2 | not-accessible | A list of fan tray module entries. | |
| INT cienaCesChassisFanTrayType | 1.3.6.1.4.1.1271.2.1.5.1.2.1.2.2.1.2 | INTEGER | read-only | This object indicates the type of fan tray. |
| I32 cienaCesChassisFCOSMappingsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.33 | Integer32 | read-only | This object indicates the maximum number of FrameCos Mappings supported on the chassis. |
| cienaCesChassisFeedPowerHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.22.1 | not-accessible | An entry in the cienaCesChassisPowerHealthTable. | |
| U32 cienaCesChassisFeedPowerHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.22.1.2 | Unsigned32 | not-accessible | Index of the power supply being monitored. |
| TCE cienaCesChassisFeedPowerHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.22.1.3 | TceHealthStatus | read-only | Health state of the power supply being monitored. |
| INT cienaCesChassisFeedPowerHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.22.1.1 | INTEGER | not-accessible | The sub-category of the power supply item being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisFeedPowerHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.22 | not-accessible | Table listing the health information of power resources. | |
| U32 cienaCesChassisFileDescriptorHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.40.1.4 | Unsigned32 | read-only | Current value of the file descriptor sub-category being monitored. |
| cienaCesChassisFileDescriptorHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.40.1 | not-accessible | An entry in the cienaCesChassisFileDescriptorHealthTable. | |
| U32 cienaCesChassisFileDescriptorHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.40.1.5 | Unsigned32 | read-only | The maximum recorded value of the file descriptor sub-category being monitored. |
| U32 cienaCesChassisFileDescriptorHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.40.1.6 | Unsigned32 | read-only | The maximum possible value of the file descriptor sub-category being monitored. |
| U32 cienaCesChassisFileDescriptorHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.40.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisFileDescriptorHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.40.1.3 | TceHealthStatus | read-only | Health state of the file descriptor sub-category being monitored. |
| INT cienaCesChassisFileDescriptorHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.40.1.1 | INTEGER | not-accessible | The sub-category of the file descriptors being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisFileDescriptorHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.40 | not-accessible | Table listing the health information of file descriptor resources. | |
| U32 cienaCesChassisFlashDriverHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.27.1.4 | Unsigned32 | read-only | Current value of the flash driver sub-category for the slot being monitored. |
| cienaCesChassisFlashDriverHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.27.1 | not-accessible | An entry in the cienaCesChassisFlashDriverHealthTable. | |
| U32 cienaCesChassisFlashDriverHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.27.1.5 | Unsigned32 | read-only | The maximum value of the flash driver sub-category for the slot being monitored. |
| U32 cienaCesChassisFlashDriverHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.27.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisFlashDriverHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.27.1.3 | TceHealthStatus | read-only | Health state of the flash driver sub-category for the slot being monitored. |
| INT cienaCesChassisFlashDriverHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.27.1.1 | INTEGER | not-accessible | The sub-category of the health-item being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisFlashDriverHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.27 | not-accessible | Table listing the health information of flash driver resources. | |
| I32 cienaCesChassisFloodContainersMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.30 | Integer32 | read-only | This object indicates the maximum number of Flood Containers supported on the chassis. |
| cienaCesChassisGlobal | 1.3.6.1.4.1.1271.2.1.5.1.1 | |||
| cienaCesChassisHealth | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4 | |||
| TCE cienaCesChassisHealthCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.1 | TceHealthCategory | accessible-for-notify | This object indicates the health category that the Health Manager monitors on the chassis. |
| TCE cienaCesChassisHealthStatus | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.3 | TceHealthStatus | accessible-for-notify | This object indicates the current health status of health category and its sub-category being monitored on the chassis. |
| NTF cienaCesChassisHealthStatusDegradedNotification | 1.3.6.1.4.1.1271.2.2.4.0.16 | This notification is sent whenever the health manager status changes to degraded for the specified cienaCesChassisHealthCategory and cienaCesChassisHealthSubCategory. The cienaCesChassisHealthStatus indicates a degraded status while the cienaCesChassisHealthStatusLast indicates the previous health status. The health status can be one of unknown, normal, warning, degraded or faulted. A degraded status typically indicates that the monitored item is experiencing major problems or is well out of range. Performance or system reliability is being affected. To enable the device to send this trap: - cienaCesChassisHealthTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| NTF cienaCesChassisHealthStatusFaultedNotification | 1.3.6.1.4.1.1271.2.2.4.0.15 | This notification is sent whenever the health manager status changes to faulted for the specified cienaCesChassisHealthCategory and cienaCesChassisHealthSubCategory. The cienaCesChassisHealthStatus indicates a faulted status while the cienaCesChassisHealthStatusLast indicates the previous health status. The health status can be one of unknown, normal, warning, degraded or faulted. A faulted status indicates that the monitored item has failed or is so far out of range that the item should be faulted. To enable the device to send this trap: - cienaCesChassisHealthTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| NTF cienaCesChassisHealthStatusGoodNotification | 1.3.6.1.4.1.1271.2.2.4.0.17 | This notification is sent whenever the health manager status changes to normal for the specified cienaCesChassisHealthCategory and cienaCesChassisHealthSubCategory. The cienaCesChassisHealthStatus indicates a normal status while the cienaCesChassisHealthStatusLast indicates the previous health status. The health status can be one of unknown, normal, warning, degraded or faulted. A normal status indicates that the monitored item is working correctly or within tolerance. To enable the device to send this trap: - cienaCesChassisHealthTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| TCE cienaCesChassisHealthStatusLast | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.4 | TceHealthStatus | accessible-for-notify | This object indicates the last known health status of health category and its sub-category being monitored on the chassis. |
| NTF cienaCesChassisHealthStatusUnknownNotification | 1.3.6.1.4.1.1271.2.2.4.0.13 | This notification is sent whenever the health manager status changes to unknown for the specified cienaCesChassisHealthCategory and cienaCesChassisHealthSubCategory. The cienaCesChassisHealthStatus indicates a warning status while the cienaCesChassisHealthStatusLast indicates the previous health status. The health status can be one of unknown, normal, warning, degraded or faulted. An unknown status indicates that the system has not yet been able to determine the initial state. This can be due to either the system still not completed booting or a component has just been installed and has not had sufficient time to initialize and provide its state to the health monitoring system. To enable the device to send this trap: - cienaCesChassisHealthTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| NTF cienaCesChassisHealthStatusWarningNotification | 1.3.6.1.4.1.1271.2.2.4.0.14 | This notification is sent whenever the health manager status changes to warning for the specified cienaCesChassisHealthCategory and cienaCesChassisHealthSubCategory. The cienaCesChassisHealthStatus indicates a warning status while the cienaCesChassisHealthStatusLast indicates the previous health status. The health status can be one of unknown, normal, warning, degraded or faulted. A warning status indicates that the monitored item is experiencing some errors or is deviated from specified ranges, but is still functional. To enable the device to send this trap: - cienaCesChassisHealthTrapState needs to be set to enabled The above object is set to enabled by default. | ||
| U32 cienaCesChassisHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.2 | Unsigned32 | accessible-for-notify | This object indicates the sub-category that has meaning specific to the value of the accompanying cienaCesChassisHealthCategory object. Refer to the specific subCategory object that corresponds to the cienaCesChassisHealthCategory for details on the particular subCategory as referenced below: TceHealthCategory value, corresponding subCategory object ---------------------------------------------------------------------- unknown(1) cpu(2) cienaCesChassisCPUHealthSubCategory datapath(3) cienaCesChassisDatapathHealthSubCategory ethernet(4) cienaCesChassisControlPlaneHealthSubCategory fabric(5) cienaCesChassisFabricHealthSubCategory sm(6) cienaCesChassisSMHealthSubCategory tempSm(7) cienaCesChassisSMTempHealthSubCategory samplesSm(8) cienaCesChassisSMSamplesHealthSubCategory disk(9) cienaCesChassisDiskHealthSubCategory tempModule(10) cienaCesChassisModuleTempHealthSubCategory samplesModule(11) cienaCesChassisModuleSamplesHealthSubCategory fanTray(12) cienaCesChassisFanTrayHealthSubCategory fanTraySpeedMismatch(13) cienaCesChassisFanTraySpeedMismatchHealthSubCategory fanSpeedMismatch(14) cienaCesChassisFanSpeedMismatchHealthSubCategory tempFan(15) cienaCesChassisFanTempHealthSubCategory samplesFan(16) cienaCesChassisFanSamplesHealthSubCategory fanRpm(17) cienaCesChassisFanRPMHealthSubCategory power(18) cienaCesChassisPowerHealthSubCategory feedPower(19) cienaCesChassisFeedPowerHealthSubCategory systemResource(20) cienaCesChassisResourceHealthSubCategory memory(21) cienaCesChassisMemoryHealthSubCategory mac(22) cienaCesChassisMACHealthSubCategory i2c(23) cienaCesChassisI2CHealthSubCategory flash(24) cienaCesChassisFlashDriverHealthSubCategory transceiver(25) cienaCesChassisXcvrHealthSubCategory link(26) cienaCesChassisPortLinkHealthSubCategory iomStatus(27) cienaCesChassisIOMStatusHealthSubCategory usbFlash(28) cienaCesChassisUsbFlashHealthSubCategory linxstats(29) cienaCesChassisLinxStatHealthSubCategory smFabric(30) cienaCesChassisSMFabricHealthSubCategory spi(31) cienaCesChassisSPIHealthSubCategory slotResource(32) cienaCesModuleResourceHealthSubCategory(cienaCesModuleMIB) tempIom(33) cienaCesChassisIomTempHealthSubCategory powerParams(34) cienaCesChassisPowerParamsHealthSubCategory powerOutputVoltage(35) cienaCesChassisPowerOutputVoltageHealthSubCategory tempModem(36) cienaCesChassisModemTempHealthSubCategory watermarkModem(37) cienaCesChassisModemWatermarkHealthSubCategory fileDescriptor(38) cienaCesChassisFileDescriptorHealthSubCategory process(39) cienaCesChassisProcessHealthSubCategory thread(40) cienaCesChassisThreadHealthSubCategory |
| cienaCesChassisI2CHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.26.1 | not-accessible | An entry in the cienaCesChassisI2CHealthTable. | |
| U32 cienaCesChassisI2CHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.26.1.3 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisI2CHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.26.1.4 | TceHealthStatus | read-only | Health state of the I2C driver for the slot being monitored. |
| INT cienaCesChassisI2CHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.26.1.1 | INTEGER | not-accessible | The sub-category of the I2C driver being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisI2CHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.26 | not-accessible | Table listing the health information of I2C based resources. | |
| cienaCesChassisIDP | 1.3.6.1.4.1.1271.2.1.5.1.2.1.5 | |||
| STR cienaCesChassisIDPBarcode | 1.3.6.1.4.1.1271.2.1.5.1.2.1.5.9 | DisplayString | read-only | This object indicates the Barcode stored in the chassis IDP. |
| STR cienaCesChassisIDPCleiCode | 1.3.6.1.4.1.1271.2.1.5.1.2.1.5.8 | DisplayString | read-only | This object indicates the CLEI Code stored in the chassis IDP. |
| MAC cienaCesChassisIDPEthBaseMac | 1.3.6.1.4.1.1271.2.1.5.1.2.1.5.1 | MacAddress | read-only | This object indicates the Ethernet Base MAC address stored in the chassis IDP. |
| I32 cienaCesChassisIDPEthBaseMacRange | 1.3.6.1.4.1.1271.2.1.5.1.2.1.5.2 | Integer32 | read-only | This object indicates the Ethernet MAC address range stored in the chassis IDP. |
| I32 cienaCesChassisIDPFTC | 1.3.6.1.4.1.1271.2.1.5.1.2.1.5.11 | Integer32 | read-only | This object indicates the Functional Test Count stored in the chassis IDP. |
| STR cienaCesChassisIDPMfgDate | 1.3.6.1.4.1.1271.2.1.5.1.2.1.5.7 | DisplayString | read-only | This object indicates the Manufactured Date stored in the chassis IDP. |
| STR cienaCesChassisIDPModelPartNumber | 1.3.6.1.4.1.1271.2.1.5.1.2.1.5.4 | DisplayString | read-only | This object indicates the Model Part Number stored in the chassis IDP. |
| STR cienaCesChassisIDPModelRevision | 1.3.6.1.4.1.1271.2.1.5.1.2.1.5.5 | DisplayString | read-only | This object indicates the Module Revision Number stored in the chassis IDP. |
| STR cienaCesChassisIDPModuleSerialNumber | 1.3.6.1.4.1.1271.2.1.5.1.2.1.5.3 | DisplayString | read-only | This object indicates the Module Serial Number stored in the chassis IDP. |
| STR cienaCesChassisIDPProductID | 1.3.6.1.4.1.1271.2.1.5.1.2.1.5.6 | DisplayString | read-only | This object indicates the Product ID stored in the chassis IDP. |
| I32 cienaCesChassisIDPSWCompat | 1.3.6.1.4.1.1271.2.1.5.1.2.1.5.10 | Integer32 | read-only | This object indicates the Software Compatibility Number stored in the chassis IDP. |
| cienaCesChassisIOM | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6 | |||
| STR cienaCesChassisIOMAlarmInputDescription | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.5.1.2 | DisplayString | read-only | Description of the IOM alarm input signal. |
| cienaCesChassisIOMAlarmInputEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.5.1 | not-accessible | An entry in the IOM alarm input table. | |
| I32 cienaCesChassisIOMAlarmInputIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.5.1.1 | Integer32 | not-accessible | IOM alarm input index, representing a distinct alarm input signal on the IOM. |
| INT cienaCesChassisIOMAlarmInputState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.5.1.3 | INTEGER | read-only | Current input state of the IOM alarm input signal. When on, the IOM alarm input signal is presently being asserted. When off, the IOM alarm input signal is not presently being asserted. Value of notSupported is returned when the IOM is not presently installed. |
| NTF cienaCesChassisIOMAlarmInputStateChangeNotification | 1.3.6.1.4.1.1271.2.2.4.0.23 | This notification is generated when the value of cienaCesChassisIOMAlarmInputState changes. | ||
| cienaCesChassisIOMAlarmInputTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.5 | not-accessible | A list of the alarm input signals and their state, as supported by the IOM. | |
| STR cienaCesChassisIOMAlarmOutputDescription | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.4.1.2 | DisplayString | read-only | Description of the IOM alarm output signal. |
| cienaCesChassisIOMAlarmOutputEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.4.1 | not-accessible | An entry in the IOM alarm output table. | |
| I32 cienaCesChassisIOMAlarmOutputIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.4.1.1 | Integer32 | not-accessible | IOM alarm output index, representing a distinct alarm output signal on the IOM. |
| INT cienaCesChassisIOMAlarmOutputState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.4.1.3 | INTEGER | read-only | Current state of the IOM alarm output signal. When on, the system presently is asserting the IOM alarm output signal. When off, the system is not presently asserting the IOM alarm output signal. Value of notSupported is returned when the IOM is not presently installed. |
| NTF cienaCesChassisIOMAlarmOutputStateChangeNotification | 1.3.6.1.4.1.1271.2.2.4.0.22 | This notification is generated when the value of cienaCesChassisIOMAlarmOutputState changes. | ||
| cienaCesChassisIOMAlarmOutputTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.4 | not-accessible | A list of the alarm output signals and their state, as supported by the IOM. | |
| T/F cienaCesChassisIOMBuzzerEnable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.2 | TruthValue | read-only | This object represents whether the on-board buzzer will alert to fan tray removal. When true, the on-board buzzer will alert while the fan tray is removed. When false, the on-board buzzer will not alert to fan tray removal. |
| NTF cienaCesChassisIOMBuzzerEnableChangeNotification | 1.3.6.1.4.1.1271.2.2.4.0.20 | This notification is generated when the value of cienaCesChassisIOMBuzzerEnable changes. | ||
| INT cienaCesChassisIOMBuzzerState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.3 | INTEGER | read-only | This object represents the current state of the on-board buzzer. When on, the on-board buzzer is presently alerting. When off, the on-board buzzer is presently silent. Value of notSupported is returned when the IOM is not presently installed. |
| NTF cienaCesChassisIOMBuzzerStateChangeNotification | 1.3.6.1.4.1.1271.2.2.4.0.21 | This notification is generated when the value of cienaCesChassisIOMBuzzerState changes. | ||
| U32 cienaCesChassisIOMChassisIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.7 | Unsigned32 | read-only | This object represents the chassis index. |
| STR cienaCesChassisIOMName | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.6 | DisplayString | read-only | This object indicates the IOM name. |
| STR cienaCesChassisIOMSerialNumber | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.10 | DisplayString | read-only | This object represent the IOM serial number. |
| U32 cienaCesChassisIOMShelfIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.8 | Unsigned32 | read-only | This object represents the chassis shelf index. |
| U32 cienaCesChassisIOMSlotIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.9 | Unsigned32 | read-only | This object represents the IOM slot index. |
| INT cienaCesChassisIOMState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.6.1 | INTEGER | read-only | Current state of the IOM. |
| NTF cienaCesChassisIOMStateChangeNotification | 1.3.6.1.4.1.1271.2.2.4.0.19 | This notification is generated when the value of cienaCesChassisIOMState changes. | ||
| cienaCesChassisIOMStatusHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.30.1 | not-accessible | An entry in the cienaCesChassisIOMStatusHealthTable. | |
| U32 cienaCesChassisIOMStatusHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.30.1.2 | Unsigned32 | not-accessible | IOM slot being monitored. |
| TCE cienaCesChassisIOMStatusHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.30.1.3 | TceHealthStatus | read-only | Health state of the IOM for the slot being monitored. |
| INT cienaCesChassisIOMStatusHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.30.1.1 | INTEGER | not-accessible | The sub-category of the IOM being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisIOMStatusHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.30 | not-accessible | Table listing the health information of IOM. | |
| U32 cienaCesChassisIomTempHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.35.1.4 | Unsigned32 | read-only | Current temperature of the IOM temperature sub-category. |
| cienaCesChassisIomTempHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.35.1 | not-accessible | An entry in the cienaCesChassisIomTempHealthTable. | |
| U32 cienaCesChassisIomTempHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.35.1.6 | Unsigned32 | read-only | The maximum recorded temperature reached by the IOM temperature sub-category. |
| U32 cienaCesChassisIomTempHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.35.1.8 | Unsigned32 | read-only | The maximum operational temperature of the IOM temperature sub-category. |
| U32 cienaCesChassisIomTempHealthMinMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.35.1.5 | Unsigned32 | read-only | The minimum recorded temperature reached by the IOM temperature sub-category. |
| U32 cienaCesChassisIomTempHealthMinThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.35.1.7 | Unsigned32 | read-only | The minimum operational temperature of the IOM temperature sub-category. |
| U32 cienaCesChassisIomTempHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.35.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisIomTempHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.35.1.3 | TceHealthStatus | read-only | Temperature state of the IOM temperature sub-category. |
| INT cienaCesChassisIomTempHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.35.1.1 | INTEGER | not-accessible | The sub-category of the IOM temperature being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisIomTempHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.35 | not-accessible | Table listing the health information of IOM temperature resources. | |
| U32 cienaCesChassisLinksPerRedundancyGroupMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.43 | Unsigned32 | read-only | The maximum number of links per redundancy group supported on this machine. |
| U32 cienaCesChassisLinxStatHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.31.1.4 | Unsigned32 | read-only | Current value of LinxStat sub-category used for the slot. |
| cienaCesChassisLinxStatHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.31.1 | not-accessible | An entry in the cienaCesChassisLinxStatHealthTable. | |
| U32 cienaCesChassisLinxStatHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.31.1.5 | Unsigned32 | read-only | The maximum recorded value of LinxStat sub-category used by the slot. |
| U32 cienaCesChassisLinxStatHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.31.1.6 | Unsigned32 | read-only | The maximum size of the LinxStat sub-category. |
| U32 cienaCesChassisLinxStatHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.31.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisLinxStatHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.31.1.3 | TceHealthStatus | read-only | LinxStat sub-category utilization state of the slot. |
| INT cienaCesChassisLinxStatHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.31.1.1 | INTEGER | not-accessible | The sub-category of the health-item being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisLinxStatHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.31 | not-accessible | Table listing the health information of linx stats. | |
| MAC cienaCesChassisMacAddress | 1.3.6.1.4.1.1271.2.1.5.1.1.1 | MacAddress | read-only | This object indicates the chassis MAC address. |
| U32 cienaCesChassisMACHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.25.1.4 | Unsigned32 | read-only | Current number of entries in the MAC table for the slot being monitored. |
| cienaCesChassisMACHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.25.1 | not-accessible | An entry in the cienaCesChassisMACHealthTable. | |
| U32 cienaCesChassisMACHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.25.1.5 | Unsigned32 | read-only | The maximum recorded number of entries in the MAC table for the slot being monitored. |
| U32 cienaCesChassisMACHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.25.1.6 | Unsigned32 | read-only | The maximum possible number of entries in the MAC table for the slot being monitored. |
| U32 cienaCesChassisMACHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.25.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisMACHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.25.1.3 | TceHealthStatus | read-only | Health state of the system MAC table for the slot being monitored. |
| INT cienaCesChassisMACHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.25.1.1 | INTEGER | not-accessible | The sub-category of the MAC table being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisMACHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.25 | not-accessible | Table listing the health information of mac-table resources. | |
| MAC cienaCesChassisMefSourceMacAddress | 1.3.6.1.4.1.1271.2.1.5.1.1.14 | MacAddress | read-only | This object indicates the chassis MEF source MAC address. |
| U32 cienaCesChassisMemoryHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.24.1.4 | Unsigned32 | read-only | Current value of the memory sub-category being monitored. |
| cienaCesChassisMemoryHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.24.1 | not-accessible | An entry in the cienaCesChassisMemoryHealthTable. | |
| U32 cienaCesChassisMemoryHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.24.1.5 | Unsigned32 | read-only | The maximum recorded value of the memory sub-category being monitored. |
| U32 cienaCesChassisMemoryHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.24.1.6 | Unsigned32 | read-only | The maximum possible value of the memory sub-category being monitored. |
| U32 cienaCesChassisMemoryHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.24.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisMemoryHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.24.1.3 | TceHealthStatus | read-only | Health state of the memory sub-category being monitored. |
| INT cienaCesChassisMemoryHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.24.1.1 | INTEGER | not-accessible | The sub-category of the memory being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisMemoryHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.24 | not-accessible | Table listing the health information of memory resources. | |
| I32 cienaCesChassisMeterProfilesMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.29 | Integer32 | read-only | This object indicates the maximum number of Meter Profiles supported on the chassis. |
| DAT cienaCesChassisMfgDate | 1.3.6.1.4.1.1271.2.1.5.1.1.5 | DateAndTime | read-only | This object indicates the chassis manufacturing date. |
| cienaCesChassisMIB | 1.3.6.1.4.1.1271.2.1.5 | This module defines the chassis configuration objects and also the objects required for any chassis related notifications. | ||
| cienaCesChassisMIBCompliances | 1.3.6.1.4.1.1271.2.1.5.2.1 | |||
| cienaCesChassisMIBConformance | 1.3.6.1.4.1.1271.2.1.5.2 | |||
| cienaCesChassisMIBGroups | 1.3.6.1.4.1.1271.2.1.5.2.2 | |||
| cienaCesChassisMIBNotificationPrefix | 1.3.6.1.4.1.1271.2.2.4 | |||
| cienaCesChassisMIBNotifications | 1.3.6.1.4.1.1271.2.2.4.0 | |||
| cienaCesChassisMIBObjects | 1.3.6.1.4.1.1271.2.1.5.1 | |||
| U32 cienaCesChassisModemTempHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.38.1.4 | Unsigned32 | read-only | Current temperature of the modem temperature sub-category. |
| cienaCesChassisModemTempHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.38.1 | not-accessible | An entry in the cienaCesChassisModemTempHealthTable. | |
| U32 cienaCesChassisModemTempHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.38.1.6 | Unsigned32 | read-only | The maximum recorded temperature reached by the modem temperature sub-category. |
| U32 cienaCesChassisModemTempHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.38.1.8 | Unsigned32 | read-only | The maximum operational temperature of the modem temperature sub-category. |
| U32 cienaCesChassisModemTempHealthMinMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.38.1.5 | Unsigned32 | read-only | The minimum recorded temperature reached by the modem temperature sub-category. |
| U32 cienaCesChassisModemTempHealthMinThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.38.1.7 | Unsigned32 | read-only | The minimum operational temperature of the modem temperature sub-category. |
| U32 cienaCesChassisModemTempHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.38.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisModemTempHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.38.1.3 | TceHealthStatus | read-only | Temperature state of the CSLM modem temp sub-category being monitored. |
| INT cienaCesChassisModemTempHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.38.1.1 | INTEGER | not-accessible | The sub-category of the CSLM modem temp being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisModemTempHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.38 | not-accessible | Table listing the health information of CSLM modem temperatures. | |
| cienaCesChassisModemWatermarkHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.39.1 | not-accessible | An entry in the cienaCesChassisModemWatermarkHealthTable. | |
| U32 cienaCesChassisModemWatermarkHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.39.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisModemWatermarkHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.39.1.3 | TceHealthStatus | read-only | Modem watermark state of the slot. |
| INT cienaCesChassisModemWatermarkHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.39.1.1 | INTEGER | not-accessible | The sub-category of the CSLM modem watermark being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisModemWatermarkHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.39 | not-accessible | Table listing the health information of CSLM watermarks. | |
| INT cienaCesChassisModuleSamplesHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.14.1.4 | INTEGER | read-only | Current measurement of module samples state of the slot. |
| cienaCesChassisModuleSamplesHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.14.1 | not-accessible | An entry in the cienaCesChassisModuleSamplesHealthTable. | |
| INT cienaCesChassisModuleSamplesHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.14.1.5 | INTEGER | read-only | Maximum measurement of module samples of the slot. |
| U32 cienaCesChassisModuleSamplesHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.14.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisModuleSamplesHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.14.1.3 | TceHealthStatus | read-only | module samples state of the slot. |
| INT cienaCesChassisModuleSamplesHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.14.1.1 | INTEGER | not-accessible | The sub-category of the module samples being monitored. - 'none' is an enumeration placeholder - 'sensorXXInvalid' indicates the number of invalid sensor reads if the 'cienaCesChassisModuleSamplesHealthCurrMeasurement' associated with this instance is a huge value ,it means something is broken. |
| cienaCesChassisModuleSamplesHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.14 | not-accessible | Table listing the health information of SM. | |
| U32 cienaCesChassisModuleTempHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.13.1.4 | Unsigned32 | read-only | Current temperature of the module temperature sub-category. |
| cienaCesChassisModuleTempHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.13.1 | not-accessible | An entry in the cienaCesChassisModuleTempHealthTable. | |
| U32 cienaCesChassisModuleTempHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.13.1.6 | Unsigned32 | read-only | The maximum recorded temperature reached by the module temperature sub-category. |
| U32 cienaCesChassisModuleTempHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.13.1.8 | Unsigned32 | read-only | The maximum operational temperature of the module temperature sub-category. |
| U32 cienaCesChassisModuleTempHealthMinMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.13.1.5 | Unsigned32 | read-only | The minimum recorded temperature reached by the module temperature sub-category. |
| U32 cienaCesChassisModuleTempHealthMinThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.13.1.7 | Unsigned32 | read-only | The minimum operational temperature of the module temperature sub-category. |
| U32 cienaCesChassisModuleTempHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.13.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisModuleTempHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.13.1.3 | TceHealthStatus | read-only | Temperature state of the module temperature sub-category. |
| INT cienaCesChassisModuleTempHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.13.1.1 | INTEGER | not-accessible | The sub-category of the module temperature being monitored. |
| cienaCesChassisModuleTempHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.13 | not-accessible | Table listing the health information of module temperature resources. | |
| I32 cienaCesChassisMPLSDecapTunnelsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.38 | Integer32 | read-only | This object indicates the maximum number of MPLS decap tunnels supported on the chassis. |
| I32 cienaCesChassisMPLSEncapTunnelsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.37 | Integer32 | read-only | This object indicates the maximum number of MPLS encap tunnels supported on the chassis. |
| I32 cienaCesChassisMPLSInterfacesMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.40 | Integer32 | read-only | This object indicates the maximum number of MPLS interfaces supported on the chassis. |
| I32 cienaCesChassisMPLSTransitTunnelsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.41 | Integer32 | read-only | This object indicates the maximum number of MPLS transit tunnels supported on the chassis. |
| I32 cienaCesChassisMPLSTunnelGroupsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.35 | Integer32 | read-only | This object indicates the maximum number of MPLS tunnel groups supported on the chassis. |
| I32 cienaCesChassisMPLSTunnelsPerGroupMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.36 | Integer32 | read-only | This object indicates the maximum number of MPLS tunnels per MPLS tunnel group supported on the chassis. |
| I32 cienaCesChassisMPLSVCMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.39 | Integer32 | read-only | This object indicates the maximum number of MPLS virtual-circuits supported on the chassis. |
| I32 cienaCesChassisMulticastGrpsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.15 | Integer32 | read-only | This object indicates the maximum number of multicast groups supported on the chassis. |
| I32 cienaCesChassisNumFansPerTray | 1.3.6.1.4.1.1271.2.1.5.1.2.2.8 | Integer32 | read-only | This object indicates the number of fans per tray. |
| I32 cienaCesChassisNumFanTrays | 1.3.6.1.4.1.1271.2.1.5.1.2.2.7 | Integer32 | read-only | This object indicates the number of fan trays in the chassis. |
| I32 cienaCesChassisNumSlots | 1.3.6.1.4.1.1271.2.1.5.1.2.2.4 | Integer32 | read-only | This object indicates the maximum number of slots on the chassis. |
| cienaCesChassisObjects | 1.3.6.1.4.1.1271.2.1.5.1.2 | |||
| STR cienaCesChassisParamVersion | 1.3.6.1.4.1.1271.2.1.5.1.1.6 | DisplayString | read-only | This object indicates the chassis param version. |
| STR cienaCesChassisPartNumber | 1.3.6.1.4.1.1271.2.1.5.1.1.3 | DisplayString | read-only | This object indicates the chassis part number. |
| I32 cienaCesChassisPBTDecapTunnelsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.26 | Integer32 | read-only | This object indicates the maximum number of PBT Decap Tunnels supported on the chassis. |
| I32 cienaCesChassisPBTEncapTunnelsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.25 | Integer32 | read-only | This object indicates the maximum number of PBT Encap Tunnels supported on the chassis. |
| I32 cienaCesChassisPBTServiceIntfcsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.27 | Integer32 | read-only | This object indicates the maximum number of PBT Service Interfaces supported on the chassis. |
| I32 cienaCesChassisPBTTransitIntfcsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.28 | Integer32 | read-only | This object indicates the maximum number of PBT Transit Interfaces supported on the chassis. |
| I32 cienaCesChassisPBTTunnelGroupsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.24 | Integer32 | read-only | This object indicates the maximum number of PBT Tunnel groups supported on the chassis. |
| I32 cienaCesChassisPhysicalPortsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.11 | Integer32 | read-only | This object indicates the maximum number of ports supported for this chassis. |
| cienaCesChassisPlatform | 1.3.6.1.4.1.1271.2.1.5.1.2.2 | |||
| STR cienaCesChassisPlatformDesc | 1.3.6.1.4.1.1271.2.1.5.1.2.2.3 | DisplayString | read-only | This object indicates the chassis description. |
| STR cienaCesChassisPlatformName | 1.3.6.1.4.1.1271.2.1.5.1.2.2.2 | DisplayString | read-only | This object indicates the chassis platform name. |
| OCT cienaCesChassisPlatformType | 1.3.6.1.4.1.1271.2.1.5.1.2.2.1 | OCTET STRING | read-only | This object indicates the chassis platform type. |
| cienaCesChassisPortLinkHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.29.1 | not-accessible | An entry in the cienaCesChassisPortLinkHealthTable. | |
| U32 cienaCesChassisPortLinkHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.29.1.2 | Unsigned32 | not-accessible | Pgid of the port being monitored. |
| TCE cienaCesChassisPortLinkHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.29.1.3 | TceHealthStatus | read-only | Health state of the port link for the port being monitored. |
| INT cienaCesChassisPortLinkHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.29.1.1 | INTEGER | not-accessible | The sub-category of the port link being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisPortLinkHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.29 | not-accessible | Table listing the health information of port link based resources. | |
| cienaCesChassisPowerEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1 | not-accessible | An entry in the power table providing objects for a power supply. | |
| cienaCesChassisPowerHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.21.1 | not-accessible | An entry in the cienaCesChassisPowerHealthTable. | |
| U32 cienaCesChassisPowerHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.21.1.2 | Unsigned32 | not-accessible | Index of the power supply being monitored. |
| TCE cienaCesChassisPowerHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.21.1.3 | TceHealthStatus | read-only | Health state of the power supply being monitored. |
| INT cienaCesChassisPowerHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.21.1.1 | INTEGER | not-accessible | The sub-category of the power supply item being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisPowerHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.21 | not-accessible | Table listing the health information of power resources. | |
| cienaCesChassisPowerModule | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1 | |||
| I32 cienaCesChassisPowerOutputVoltageHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1.4 | Integer32 | read-only | Current voltage of the Output VOltage sub-category. |
| cienaCesChassisPowerOutputVoltageHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1 | not-accessible | An entry in the cienaCesChassisPowerOutputVoltageHealthTable. | |
| I32 cienaCesChassisPowerOutputVoltageHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1.6 | Integer32 | read-only | The maximum recorded voltage reached by the Power Supply output voltage sub-category. |
| I32 cienaCesChassisPowerOutputVoltageHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1.8 | Integer32 | read-only | The maximum operational voltage of the Power Supply output voltage sub-category. |
| I32 cienaCesChassisPowerOutputVoltageHealthMinMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1.5 | Integer32 | read-only | The minimum recorded voltage reached by the Power Supply output voltage sub-category. |
| I32 cienaCesChassisPowerOutputVoltageHealthMinThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1.7 | Integer32 | read-only | The minimum operational voltage of the Power Supply output voltage sub-category. |
| U32 cienaCesChassisPowerOutputVoltageHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisPowerOutputVoltageHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1.3 | TceHealthStatus | read-only | Voltage state of the Output Voltage sub-category. |
| INT cienaCesChassisPowerOutputVoltageHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1.1 | INTEGER | not-accessible | The sub-category of the Power Supply output voltage being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisPowerOutputVoltageHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37 | not-accessible | Table listing the health information of Power Supply output voltage. | |
| cienaCesChassisPowerParamsHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.36.1 | not-accessible | An entry in the cienaCesChassisPowerParamsHealthTable. | |
| U32 cienaCesChassisPowerParamsHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.36.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisPowerParamsHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.36.1.3 | TceHealthStatus | read-only | Current status of the Power Parameters sub-category. |
| INT cienaCesChassisPowerParamsHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.36.1.1 | INTEGER | not-accessible | The sub-category of the Power Params being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisPowerParamsHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.36 | not-accessible | Table listing the health information of Power Supply parameters. | |
| U32 cienaCesChassisPowerSupplyChassisIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.11 | Unsigned32 | read-only | This object represents the chassis index. |
| NTF cienaCesChassisPowerSupplyFaultedNotification | 1.3.6.1.4.1.1271.2.2.4.0.1 | A cienaCesChassisPowerSupplyFaultedNotification is sent if a power supply state changes to one of these: - faulted (2) - offline (3) - unequipped(4) To enable the device to send this trap: - cienaCesChassisAllPowerSupplyTrapState needs to be set to enabled cienaCesChassisAllPowerSupplyTrapState is set to enabled by default. | ||
| T/F cienaCesChassisPowerSupplyFRU | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.8 | TruthValue | read-only | This object indicates whether or not the power supply is a field replaceable unit (FRU). It returns true if the unit is an FRU. |
| I32 cienaCesChassisPowerSupplyIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.1 | Integer32 | not-accessible | This object indicates the unique index of the table. |
| STR cienaCesChassisPowerSupplyManufacturer | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.4 | DisplayString | read-only | Specifies the power supply manufacturer or the manufacturer specific model name of the power supply. |
| I32 cienaCesChassisPowerSupplyNotifIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.7 | Integer32 | accessible-for-notify | This object indicates the unique index of the table that is used in the definition of power-supply traps. |
| NTF cienaCesChassisPowerSupplyOnlineNotification | 1.3.6.1.4.1.1271.2.2.4.0.2 | A cienaCesChassisPowerSupplyOnlineNotification is sent if a power supply state changes to online(1). To enable the device to send this trap: - cienaCesChassisAllPowerSupplyTrapState needs to be set to enabled cienaCesChassisAllPowerSupplyTrapState is set to enabled by default. | ||
| STR cienaCesChassisPowerSupplyPartNum | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.6 | DisplayString | read-only | Specifies the power supply part number. |
| STR cienaCesChassisPowerSupplyRevInfo | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.10 | DisplayString | read-only | Specifies the revision information of the power supply. |
| STR cienaCesChassisPowerSupplySerialNumber | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.5 | DisplayString | read-only | Specifies the power supply serial number. |
| U32 cienaCesChassisPowerSupplyShelfIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.12 | Unsigned32 | read-only | This object represents the chassis shelf index. |
| U32 cienaCesChassisPowerSupplySlotIndx | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.13 | Unsigned32 | read-only | This object represents the power supply chassis slot index. |
| STR cienaCesChassisPowerSupplySlotName | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.9 | DisplayString | read-only | Specifies the name of the chassis slot in which the power supply is installed. |
| INT cienaCesChassisPowerSupplyState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.2 | INTEGER | read-only | Specifies the state of the power supply. |
| INT cienaCesChassisPowerSupplyType | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.3 | INTEGER | read-only | Specifies the power supply type. |
| cienaCesChassisPowerTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1 | not-accessible | A list of power supply entries. | |
| I32 cienaCesChassisPrimaryCtrlSlot | 1.3.6.1.4.1.1271.2.1.5.1.2.2.5 | Integer32 | read-only | This object indicates the slot number of primary control card. |
| U32 cienaCesChassisProcessHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.41.1.4 | Unsigned32 | read-only | Current value of the process sub-category being monitored. |
| cienaCesChassisProcessHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.41.1 | not-accessible | An entry in the cienaCesChassisProcessHealthTable. | |
| U32 cienaCesChassisProcessHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.41.1.5 | Unsigned32 | read-only | The maximum recorded value of the process sub-category being monitored. |
| U32 cienaCesChassisProcessHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.41.1.6 | Unsigned32 | read-only | The maximum possible value of the process sub-category being monitored. |
| U32 cienaCesChassisProcessHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.41.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisProcessHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.41.1.3 | TceHealthStatus | read-only | Health state of the process sub-category being monitored. |
| INT cienaCesChassisProcessHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.41.1.1 | INTEGER | not-accessible | The sub-category of the process being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisProcessHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.41 | not-accessible | Table listing the health information of process resources. | |
| I32 cienaCesChassisQosFlowsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.21 | Integer32 | read-only | This object indicates the maximum number of QoS Flows supported on the chassis. |
| I32 cienaCesChassisRCOSMappingsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.32 | Integer32 | read-only | This object indicates the maximum number of ResolvedCos Mappings supported on the chassis. |
| I32 cienaCesChassisRCOSProfilesMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.31 | Integer32 | read-only | This object indicates the maximum number of ResolvedCos Profiles supported on the chassis. |
| NTF cienaCesChassisRebootNotification | 1.3.6.1.4.1.1271.2.2.4.0.18 | A cienaCesChassisRebootNotification is sent when the device is rebooted. The cienaCesChassisRebootNotification has no guarantee to be sent upon a reboot and will likely misbehave if informs are used. If sent, the cienaCesChassisRebootReasonErrorType is set to indicate the reboot reason. | ||
| INT cienaCesChassisRebootReasonErrorType | 1.3.6.1.4.1.1271.2.1.5.1.1.10 | INTEGER | accessible-for-notify | This variable indicates the type of reboot reasons included in the cienaCesChassisRebootNotification trap. |
| U32 cienaCesChassisRedundancyGroupsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.42 | Unsigned32 | read-only | The maximum number of redundancy groups supported on this machine. |
| INT cienaCesChassisRedunPower | 1.3.6.1.4.1.1271.2.1.5.1.2.2.10 | INTEGER | read-only | This object indicates if redundant power is supported for this chassis or not. |
| I32 cienaCesChassisReplicMCPortPerVsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.19 | Integer32 | read-only | This object indicates the maximum number of Mcast Virtual Interfaces Per logical port per Vswitch supported on the chassis. |
| I32 cienaCesChassisReplicPerPortPerVsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.18 | Integer32 | read-only | This object indicates the maximum number of Virtual interfaces per logical port per Vswitch supported on the chassis. |
| U32 cienaCesChassisResourceHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.23.1.3 | Unsigned32 | read-only | Current value of the dataplane resource being monitored. |
| cienaCesChassisResourceHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.23.1 | not-accessible | An entry in the cienaCesChassisResourceHealthTable. | |
| U32 cienaCesChassisResourceHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.23.1.4 | Unsigned32 | read-only | The maximum recorded value of the dataplane resource being monitored. |
| U32 cienaCesChassisResourceHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.23.1.5 | Unsigned32 | read-only | The maximum possible value for the dataplane resource being monitored. |
| TCE cienaCesChassisResourceHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.23.1.2 | TceHealthStatus | read-only | Health state of the dataplane resource being monitored. |
| INT cienaCesChassisResourceHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.23.1.1 | INTEGER | not-accessible | The sub-category of the dataplane resource being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisResourceHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.23 | not-accessible | Table listing the health information of dataplane resources. | |
| T/F cienaCesChassisRestart | 1.3.6.1.4.1.1271.2.1.5.1.1.13 | TruthValue | read-write | This object restarts the chassis. Setting the value of this object to true will restart the chassis immediately. When read, this object will always return false. |
| I32 cienaCesChassisRstpDomainsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.16 | Integer32 | read-only | This object indicates the maximum number of RSTP domains supported on the chassis. |
| I32 cienaCesChassisSecondaryCtrlSlot | 1.3.6.1.4.1.1271.2.1.5.1.2.2.6 | Integer32 | read-only | This object indicates the slot number of secondary control card. |
| STR cienaCesChassisSerialNumber | 1.3.6.1.4.1.1271.2.1.5.1.1.4 | DisplayString | read-only | This object indicates the chassis serial number. |
| I32 cienaCesChassisShapingProfilesMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.34 | Integer32 | read-only | This object indicates the maximum number of Shaping Profiles supported on the chassis. |
| cienaCesChassisSMFabricHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.32.1 | not-accessible | An entry in the cienaCesChassisSMFabricHealthTable. | |
| U32 cienaCesChassisSMFabricHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.32.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisSMFabricHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.32.1.3 | TceHealthStatus | read-only | Health state of the SM fabric sub-category. |
| INT cienaCesChassisSMFabricHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.32.1.1 | INTEGER | not-accessible | The sub-category of the SM fabric being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisSMFabricHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.32 | not-accessible | Table listing the health information of SM fabric resources. | |
| cienaCesChassisSMHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.9.1 | not-accessible | An entry in the cienaCesChassisSMHealthTable. | |
| U32 cienaCesChassisSMHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.9.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisSMHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.9.1.4 | TceHealthStatus | read-only | SM state of the slot. |
| INT cienaCesChassisSMHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.9.1.1 | INTEGER | not-accessible | The sub-category of the SM being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisSMHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.9 | not-accessible | Table listing the health information of SM. | |
| INT cienaCesChassisSMSamplesHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.11.1.4 | INTEGER | read-only | SM state of the slot. |
| cienaCesChassisSMSamplesHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.11.1 | not-accessible | An entry in the cienaCesChassisSMHealthTable. | |
| INT cienaCesChassisSMSamplesHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.11.1.5 | INTEGER | read-only | SM state of the slot. |
| U32 cienaCesChassisSMSamplesHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.11.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisSMSamplesHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.11.1.3 | TceHealthStatus | read-only | SM state of the slot. |
| INT cienaCesChassisSMSamplesHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.11.1.1 | INTEGER | not-accessible | The sub-category of the SM being monitored. - 'none' is an enumeration placeholder - 'invalid' indicates the number of invalid sensor reads if the 'cienaCesChassisSMSamplesHealthCurrMeasurement' associated with this instance is a huge value ,it means something is broken. |
| cienaCesChassisSMSamplesHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.11 | not-accessible | Table listing the health information of SM. | |
| U32 cienaCesChassisSMTempHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.10.1.4 | Unsigned32 | read-only | Current temperature of the SM temperature sub-category. |
| cienaCesChassisSMTempHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.10.1 | not-accessible | An entry in the cienaCesChassisSMTempHealthTable. | |
| U32 cienaCesChassisSMTempHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.10.1.6 | Unsigned32 | read-only | The maximum recorded temperature reached by the SM temperature sub-category. |
| U32 cienaCesChassisSMTempHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.10.1.8 | Unsigned32 | read-only | The maximum operational temperature of the SM temperature sub-category. |
| U32 cienaCesChassisSMTempHealthMinMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.10.1.5 | Unsigned32 | read-only | The minimum recorded temperature reached by the SM temperature sub-category. |
| U32 cienaCesChassisSMTempHealthMinThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.10.1.7 | Unsigned32 | read-only | The minimum operational temperature of the SM temperature sub-category. |
| U32 cienaCesChassisSMTempHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.10.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisSMTempHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.10.1.3 | TceHealthStatus | read-only | Temperature state of the module temperature sub-category. |
| INT cienaCesChassisSMTempHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.10.1.1 | INTEGER | not-accessible | The sub-category of the SM temperature being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisSMTempHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.10 | not-accessible | Table listing the health information of SM temperature resources. | |
| cienaCesChassisSPIHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.33.1 | not-accessible | An entry in the cienaCesChassisSPIHealthTable. | |
| U32 cienaCesChassisSPIHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.33.1.3 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisSPIHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.33.1.4 | TceHealthStatus | read-only | Health state of the SPI driver for the slot being monitored. |
| INT cienaCesChassisSPIHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.33.1.1 | INTEGER | not-accessible | The sub-category of the SPI driver being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisSPIHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.33 | not-accessible | Table listing the health information of SPI based resources. | |
| I32 cienaCesChassisSubPortsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.20 | Integer32 | read-only | This object indicates the maximum number of Sub Ports supported on the chassis. |
| STR cienaCesChassisSystemDateAndTime | 1.3.6.1.4.1.1271.2.1.5.1.1.7 | DisplayString | read-only | This object displays local system date and time. |
| STR cienaCesChassisSystemId | 1.3.6.1.4.1.1271.2.1.5.1.1.11 | DisplayString | accessible-for-notify | This object indicates the system identification (SID) as provisioned by the operator through TL1. |
| I32 cienaCesChassisSystemTimeOffset | 1.3.6.1.4.1.1271.2.1.5.1.1.9 | Integer32 | read-only | This object displays the time offset in seconds. Valid range is -43200 .. 50400. This range corresponds to -12Hr, +14Hr consistent with the maximum time zone spacing |
| STR cienaCesChassisSystemUTCDateAndTime | 1.3.6.1.4.1.1271.2.1.5.1.1.8 | DisplayString | read-only | This object displays coordinated UTC system date and time. |
| U32 cienaCesChassisThreadHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.42.1.4 | Unsigned32 | read-only | Current value of the thread sub-category being monitored. |
| cienaCesChassisThreadHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.42.1 | not-accessible | An entry in the cienaCesChassisThreadHealthTable. | |
| U32 cienaCesChassisThreadHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.42.1.5 | Unsigned32 | read-only | The maximum recorded value of the thread sub-category being monitored. |
| U32 cienaCesChassisThreadHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.42.1.6 | Unsigned32 | read-only | The maximum possible value of the thread sub-category being monitored. |
| U32 cienaCesChassisThreadHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.42.1.2 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisThreadHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.42.1.3 | TceHealthStatus | read-only | Health state of the thread sub-category being monitored. |
| INT cienaCesChassisThreadHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.42.1.1 | INTEGER | not-accessible | The sub-category of the thread being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisThreadHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.42 | not-accessible | Table listing the health information of thread resources. | |
| NTF cienaCesChassisUsbFlashDisabledNotification | 1.3.6.1.4.1.1271.2.2.4.0.25 | This notification is generated when CTX USB hubs are disabled via user config. | ||
| NTF cienaCesChassisUsbFlashEnabledNotification | 1.3.6.1.4.1.1271.2.2.4.0.24 | This notification is generated when CTX USB hubs are enabled via user config. | ||
| cienaCesChassisUsbFlashHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.34.1 | not-accessible | An entry in the cienaCesChassisUsbFlashHealthTable. | |
| U32 cienaCesChassisUsbFlashHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.34.1.3 | Unsigned32 | not-accessible | Index of the slot being monitored. |
| TCE cienaCesChassisUsbFlashHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.34.1.4 | TceHealthStatus | read-only | Health state of the Usb Flash for the slot being monitored. |
| INT cienaCesChassisUsbFlashHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.34.1.1 | INTEGER | not-accessible | The sub-category of the Usb Flash being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisUsbFlashHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.34 | not-accessible | Table listing the health information of Usb Flash based resources. | |
| I32 cienaCesChassisVirtualInterfaceMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.14 | Integer32 | read-only | This object indicates the maximum number of virtual interfaces supported on the chassis. |
| I32 cienaCesChassisVirtualInterfacePerVsMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.17 | Integer32 | read-only | This object indicates the maximum number of virtual interfaces per VS supported on the chassis. |
| I32 cienaCesChassisVirtualSwitchMax | 1.3.6.1.4.1.1271.2.1.5.1.2.2.13 | Integer32 | read-only | This object indicates the maximum number of virtual switches supported on the chassis. |
| U32 cienaCesChassisXcvrHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.28.1.4 | Unsigned32 | read-only | Current value of the transceiver sub-category for the pgid being monitored. |
| cienaCesChassisXcvrHealthEntry | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.28.1 | not-accessible | An entry in the cienaCesChassisXcvrHealthTable. | |
| U32 cienaCesChassisXcvrHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.28.1.6 | Unsigned32 | read-only | The maximum recorded value of the transceiver sub-category for the pgid being monitored. |
| U32 cienaCesChassisXcvrHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.28.1.8 | Unsigned32 | read-only | The maximum operational value for the transceiver sub-category for the pgid being monitored. |
| U32 cienaCesChassisXcvrHealthMinMeasurement | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.28.1.5 | Unsigned32 | read-only | The minimum recorded value of the transceiver sub-category for the pgid being monitored. |
| U32 cienaCesChassisXcvrHealthMinThreshold | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.28.1.7 | Unsigned32 | read-only | The minimum operational value for the transceiver sub-category for the pgid being monitored. |
| U32 cienaCesChassisXcvrHealthOriginIndex | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.28.1.2 | Unsigned32 | not-accessible | Pgid of the transceiver being monitored. |
| TCE cienaCesChassisXcvrHealthState | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.28.1.3 | TceHealthStatus | read-only | Health state of the transceiver sub-category for the pgid being monitored. |
| INT cienaCesChassisXcvrHealthSubCategory | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.28.1.1 | INTEGER | not-accessible | The sub-category of the transceiver being monitored. - 'none' is an enumeration placeholder |
| cienaCesChassisXcvrHealthTable | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.28 | not-accessible | Table listing the health information of transciever resources. | |
| INT cienaCesChassisXcvrHealthUnit | 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.28.1.9 | INTEGER | read-only | The unit applicable to the current, minimum, maximum, minimum threshold and maximum threshold values of the transceiver sub-category being monitored. |
RFC description
Manages chassis configuration and health status for Ciena CES (Common Equipment Software) optical systems; vendor-private chassis/module monitoring.
Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.