All MIBs › AlphaPowerSystem-MIB
Organization: Alpha Technologies
Last Updated: 2011-02-22
Category: Hardware and Environment
Description: Alpha Technologies enterprise power system MIB providing high-level status and identity for complete power plant systems.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is AlphaPowerSystem-MIB?
AlphaPowerSystem-MIB is Alpha Technologies' enterprise MIB providing high-level status and identity information for its Cordex series of DC power system controllers, used to manage complete telecom power plants. It exposes system-level identity data and an overall operational status summarizing the health of the power system as a whole. Its main monitoring value is hardware status: it lets an operator confirm the power plant controller is healthy, identify the specific controller model/system in use, and detect a system-wide alarm or fault condition. As a self-contained enterprise MIB it has no notable dependency on other standard MIBs, standing apart from the more granular UPS-MIB style modules. It is typically deployed in telecom central offices or utility sites where Cordex controllers manage racks of rectifiers and batteries powering critical equipment. Engineers can download the AlphaPowerSystem-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in AlphaPowerSystem-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Alpha Technologies Cordex DC power system controller
- telecom power plant / rectifier cabinet
Monitoring Examples
An operator would poll the system identity and overall status objects for a Cordex controller to confirm the power plant is reporting normal operation, and would investigate immediately if the status object transitions to a fault or alarm state. Because the MIB summarizes the entire power system rather than individual rectifiers, a status change here is typically used as a trigger to drill into the controller's local interface or a more detailed vendor MIB for root-cause diagnosis.
What Can Be Monitored
- power system identity/model
- overall system operational status
- power plant alarm condition
- controller configuration summary
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-SMI
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| enterprises |
From SNMPv2-TC
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| alpha | 1.3.6.1.4.1.7309 | This MIB defines the information block(s) available in system controllers as defined by the following list: - dcPwrSysDevice: Cordex series of Controllers | ||
| dcpower | 1.3.6.1.4.1.7309.4 | |||
| dcPwrExternalControls | 1.3.6.1.4.1.7309.4.1.8 | |||
| INT dcPwrSysAdioAlrmCount | 1.3.6.1.4.1.7309.4.1.5.10.1 | INTEGER | read-only | Number of control alarm variables in Adio alarm table. |
| dcPwrSysAdioAlrmEntry | 1.3.6.1.4.1.7309.4.1.5.10.2.1 | not-accessible | An entry into the Adio alarm group. | |
| INT dcPwrSysAdioAlrmIndex | 1.3.6.1.4.1.7309.4.1.5.10.2.1.1 | INTEGER | read-only | The index of the alarm variable in the table Adio alarm group. |
| INT dcPwrSysAdioAlrmIntegerValue | 1.3.6.1.4.1.7309.4.1.5.10.2.1.3 | INTEGER | read-only | The integer value of the alarm variable as reported by the Adio alarm group. |
| STR dcPwrSysAdioAlrmName | 1.3.6.1.4.1.7309.4.1.5.10.2.1.2 | DisplayString | read-only | The description of the alarm variable as reported by the Adio alarm group. |
| INT dcPwrSysAdioAlrmSeverity | 1.3.6.1.4.1.7309.4.1.5.10.2.1.5 | INTEGER | read-only | The integer value of alarm severity level of the extra variable as reported by the control alarm group. |
| STR dcPwrSysAdioAlrmStringValue | 1.3.6.1.4.1.7309.4.1.5.10.2.1.4 | DisplayString | read-only | The string value of the alarm variable as reported by the Adio alarm group. |
| dcPwrSysAdioAlrmTable | 1.3.6.1.4.1.7309.4.1.5.10.2 | not-accessible | A table of Adio alarm variables. | |
| dcPwrSysAdioAlrmTbl | 1.3.6.1.4.1.7309.4.1.5.10 | |||
| NTF dcPwrSysAgentShutdownTrap | 1.3.6.1.4.1.7309.4.1.3.0.7 | A trap to indicate that the agent software has shutdown. | ||
| NTF dcPwrSysAgentStartupTrap | 1.3.6.1.4.1.7309.4.1.3.0.6 | A trap to indicate that the agent software has started up. | ||
| NTF dcPwrSysAlarmActiveTrap | 1.3.6.1.4.1.7309.4.1.3.0.1 | A trap issued when one of the alarms on the became active. | ||
| NTF dcPwrSysAlarmClearedTrap | 1.3.6.1.4.1.7309.4.1.3.0.2 | A trap issued when one of the active alarms on the is cleared. | ||
| INT dcPwrSysAlarmTriggerValue | 1.3.6.1.4.1.7309.4.1.9.1 | INTEGER | read-only | |
| dcPwrSysAlrmsTbl | 1.3.6.1.4.1.7309.4.1.5 | |||
| INT dcPwrSysAnalogOpCount | 1.3.6.1.4.1.7309.4.1.4.2.1 | INTEGER | read-only | Number of analog output variables in system controller analog output table. |
| dcPwrSysAnalogOpEntry | 1.3.6.1.4.1.7309.4.1.4.2.2.1 | not-accessible | An entry into the DC power system controller analog output group. | |
| INT dcPwrSysAnalogOpIndex | 1.3.6.1.4.1.7309.4.1.4.2.2.1.1 | INTEGER | read-only | The index of the analog variable in the power system controller analog output group. |
| INT dcPwrSysAnalogOpIntegerValue | 1.3.6.1.4.1.7309.4.1.4.2.2.1.3 | INTEGER | read-only | The integer value of the analog variable as reported by the DC power system controller analog output group. |
| STR dcPwrSysAnalogOpName | 1.3.6.1.4.1.7309.4.1.4.2.2.1.2 | DisplayString | read-only | The description of the analog variable as reported by the DC power system controller analog output group. |
| INT dcPwrSysAnalogOpSeverity | 1.3.6.1.4.1.7309.4.1.4.2.2.1.5 | INTEGER | read-only | The integer value of analog severity level of the extra variable as reported by the DC power system controller analog output group. |
| STR dcPwrSysAnalogOpStringValue | 1.3.6.1.4.1.7309.4.1.4.2.2.1.4 | DisplayString | read-only | The string value of the analog variable as reported by the DC power system controller analog output group. |
| dcPwrSysAnalogOpTable | 1.3.6.1.4.1.7309.4.1.4.2.2 | not-accessible | A table of DC power system controller analog output variables. | |
| dcPwrSysAnalogOpTbl | 1.3.6.1.4.1.7309.4.1.4.2 | |||
| INT dcPwrSysBattAlrmCount | 1.3.6.1.4.1.7309.4.1.5.5.1 | INTEGER | read-only | Number of battery alarm variables in system controller alarm table. |
| dcPwrSysBattAlrmEntry | 1.3.6.1.4.1.7309.4.1.5.5.2.1 | not-accessible | An entry into the DC power system controller battery alarm group. | |
| INT dcPwrSysBattAlrmIndex | 1.3.6.1.4.1.7309.4.1.5.5.2.1.1 | INTEGER | read-only | The index of the alarm variable in the DC power system controller table battery alarm group. |
| INT dcPwrSysBattAlrmIntegerValue | 1.3.6.1.4.1.7309.4.1.5.5.2.1.3 | INTEGER | read-only | The integer value of the alarm variable as reported by the DC power system controller battery alarm group. |
| STR dcPwrSysBattAlrmName | 1.3.6.1.4.1.7309.4.1.5.5.2.1.2 | DisplayString | read-only | The description of the alarm variable as reported by the DC power system controller battery alarm group. |
| INT dcPwrSysBattAlrmSeverity | 1.3.6.1.4.1.7309.4.1.5.5.2.1.5 | INTEGER | read-only | The integer value of alarm severity level of the extra variable as reported by the DC power system controller battery alarm group. |
| STR dcPwrSysBattAlrmStringValue | 1.3.6.1.4.1.7309.4.1.5.5.2.1.4 | DisplayString | read-only | The string value of the alarm variable as reported by the DC power system controller battery alarm group. |
| dcPwrSysBattAlrmTable | 1.3.6.1.4.1.7309.4.1.5.5.2 | not-accessible | A table of DC power system controller battery alarm variables. | |
| dcPwrSysBattAlrmTbl | 1.3.6.1.4.1.7309.4.1.5.5 | |||
| INT dcPwrSysChargeAmps | 1.3.6.1.4.1.7309.4.1.1.3 | INTEGER | read-only | This value indicates the present battery currrent. The integer value represent a two digit fix decimal (Value = real current * 100) in Amps. |
| INT dcPwrSysChargeVolts | 1.3.6.1.4.1.7309.4.1.1.1 | INTEGER | read-only | This value indicates the present battery voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volts. |
| INT dcPwrSysCntrlrIpCount | 1.3.6.1.4.1.7309.4.1.6.2.1 | INTEGER | read-only | Number of controller input variables in system controller controller input table. |
| dcPwrSysCntrlrIpEntry | 1.3.6.1.4.1.7309.4.1.6.2.2.1 | not-accessible | An entry into the controller input group. | |
| INT dcPwrSysCntrlrIpIndex | 1.3.6.1.4.1.7309.4.1.6.2.2.1.1 | INTEGER | read-only | The index of the controller input variable in the table controller input group. |
| INT dcPwrSysCntrlrIpIntegerValue | 1.3.6.1.4.1.7309.4.1.6.2.2.1.3 | INTEGER | read-only | The integer value of the controller input variable as reported by the controller input group. |
| STR dcPwrSysCntrlrIpName | 1.3.6.1.4.1.7309.4.1.6.2.2.1.2 | DisplayString | read-only | The description of the controller input variable as reported by the controller input group. |
| STR dcPwrSysCntrlrIpStringValue | 1.3.6.1.4.1.7309.4.1.6.2.2.1.4 | DisplayString | read-only | The string value of the controller input variable as reported by the controller input group. |
| dcPwrSysCntrlrIpTable | 1.3.6.1.4.1.7309.4.1.6.2.2 | not-accessible | A table of controller input variables. | |
| dcPwrSysCntrlrIpTbl | 1.3.6.1.4.1.7309.4.1.6.2 | |||
| NTF dcPwrSysComErrTrap | 1.3.6.1.4.1.7309.4.1.3.0.5 | A trap to indicate that communications with a DC power system controller has been lost. | ||
| NTF dcPwrSysComOKTrap | 1.3.6.1.4.1.7309.4.1.3.0.4 | A trap to indicate that communications with a DC power system controller has been established. | ||
| STR dcPwrSysContactName | 1.3.6.1.4.1.7309.4.1.2.5 | DisplayString | read-only | Contact Name |
| INT dcPwrSysConvAlrmCount | 1.3.6.1.4.1.7309.4.1.5.11.1 | INTEGER | read-only | Number of Converter alarm variables in system controller alarm table. |
| dcPwrSysConvAlrmEntry | 1.3.6.1.4.1.7309.4.1.5.11.2.1 | not-accessible | An entry into the Converter alarm group. | |
| INT dcPwrSysConvAlrmIndex | 1.3.6.1.4.1.7309.4.1.5.11.2.1.1 | INTEGER | read-only | The index of the alarm variable in the DC power system controller table Converter alarm group. |
| INT dcPwrSysConvAlrmIntegerValue | 1.3.6.1.4.1.7309.4.1.5.11.2.1.3 | INTEGER | read-only | The integer value of the alarm variable as reported by the Converter alarm group. |
| STR dcPwrSysConvAlrmName | 1.3.6.1.4.1.7309.4.1.5.11.2.1.2 | DisplayString | read-only | The description of the alarm variable as reported by the Converter alarm group. |
| INT dcPwrSysConvAlrmSeverity | 1.3.6.1.4.1.7309.4.1.5.11.2.1.5 | INTEGER | read-only | The integer value of alarm severity level of the extra variable as reported by the Converter alarm group. |
| STR dcPwrSysConvAlrmStringValue | 1.3.6.1.4.1.7309.4.1.5.11.2.1.4 | DisplayString | read-only | The string value of the alarm variable as reported by the Converter alarm group. |
| dcPwrSysConvAlrmTable | 1.3.6.1.4.1.7309.4.1.5.11.2 | not-accessible | A table of Converter alarm variables. | |
| dcPwrSysConvAlrmTbl | 1.3.6.1.4.1.7309.4.1.5.11 | |||
| INT dcPwrSysConvIpCount | 1.3.6.1.4.1.7309.4.1.6.5.1 | INTEGER | read-only | Number of Converter input variables in system controller Converter input table. |
| dcPwrSysConvIpEntry | 1.3.6.1.4.1.7309.4.1.6.5.2.1 | not-accessible | An entry into the Converter input group. | |
| INT dcPwrSysConvIpIndex | 1.3.6.1.4.1.7309.4.1.6.5.2.1.1 | INTEGER | read-only | The index of the Converter input variable in the table Converter input group. |
| INT dcPwrSysConvIpIntegerValue | 1.3.6.1.4.1.7309.4.1.6.5.2.1.3 | INTEGER | read-only | The integer value of the Converter input variable as reported by the Converter input group. |
| STR dcPwrSysConvIpName | 1.3.6.1.4.1.7309.4.1.6.5.2.1.2 | DisplayString | read-only | The description of the Converter input variable as reported by the Converter input group. |
| STR dcPwrSysConvIpStringValue | 1.3.6.1.4.1.7309.4.1.6.5.2.1.4 | DisplayString | read-only | The string value of the Converter input variable as reported by the Converter input group. |
| dcPwrSysConvIpTable | 1.3.6.1.4.1.7309.4.1.6.5.2 | not-accessible | A table of Converter input variables. | |
| dcPwrSysConvIpTbl | 1.3.6.1.4.1.7309.4.1.6.5 | |||
| INT dcPwrSysCounterIpCount | 1.3.6.1.4.1.7309.4.1.6.7.1 | INTEGER | read-only | Number of Counter input variables in system controller Counter input table. |
| dcPwrSysCounterIpEntry | 1.3.6.1.4.1.7309.4.1.6.7.2.1 | not-accessible | An entry into the Counter input group. | |
| INT dcPwrSysCounterIpIndex | 1.3.6.1.4.1.7309.4.1.6.7.2.1.1 | INTEGER | read-only | The index of the Counter input variable in the table Counter input group. |
| INT dcPwrSysCounterIpIntegerValue | 1.3.6.1.4.1.7309.4.1.6.7.2.1.3 | INTEGER | read-only | The integer value of the Counter input variable as reported by the Counter input group. |
| STR dcPwrSysCounterIpName | 1.3.6.1.4.1.7309.4.1.6.7.2.1.2 | DisplayString | read-only | The description of the Counter input variable as reported by the Counter input group. |
| STR dcPwrSysCounterIpStringValue | 1.3.6.1.4.1.7309.4.1.6.7.2.1.4 | DisplayString | read-only | The string value of the Counter input variable as reported by the Counter input group. |
| dcPwrSysCounterIpTable | 1.3.6.1.4.1.7309.4.1.6.7.2 | not-accessible | A table of Counter input variables. | |
| dcPwrSysCounterIpTbl | 1.3.6.1.4.1.7309.4.1.6.7 | |||
| INT dcPwrSysCtrlAlrmCount | 1.3.6.1.4.1.7309.4.1.5.9.1 | INTEGER | read-only | The number of control alarm variables. |
| dcPwrSysCtrlAlrmEntry | 1.3.6.1.4.1.7309.4.1.5.9.2.1 | not-accessible | An entry of the control alarm group | |
| INT dcPwrSysCtrlAlrmIndex | 1.3.6.1.4.1.7309.4.1.5.9.2.1.1 | INTEGER | read-only | The index of the alarm variable in the control alarm group. |
| INT dcPwrSysCtrlAlrmIntegerValue | 1.3.6.1.4.1.7309.4.1.5.9.2.1.3 | INTEGER | read-only | The integer value of the alarm variable as reported by the control alarm group. |
| STR dcPwrSysCtrlAlrmName | 1.3.6.1.4.1.7309.4.1.5.9.2.1.2 | DisplayString | read-only | The description of the alarm variable as reported by the control alarm group. |
| INT dcPwrSysCtrlAlrmSeverity | 1.3.6.1.4.1.7309.4.1.5.9.2.1.5 | INTEGER | read-only | The integer value of alarm severity level of the extra variable as reported by the control alarm group. |
| STR dcPwrSysCtrlAlrmStringValue | 1.3.6.1.4.1.7309.4.1.5.9.2.1.4 | DisplayString | read-only | The string value of the alarm variable as reported by the control alarm group. |
| dcPwrSysCtrlAlrmTable | 1.3.6.1.4.1.7309.4.1.5.9.2 | not-accessible | A table of control alarm variables. | |
| dcPwrSysCtrlAlrmTbl | 1.3.6.1.4.1.7309.4.1.5.9 | |||
| INT dcPwrSysCurrAlrmCount | 1.3.6.1.4.1.7309.4.1.5.3.1 | INTEGER | read-only | Number of current alarm variables in system controller alarm table. |
| dcPwrSysCurrAlrmEntry | 1.3.6.1.4.1.7309.4.1.5.3.2.1 | not-accessible | An entry into the DC power system controller current alarm group. | |
| INT dcPwrSysCurrAlrmIndex | 1.3.6.1.4.1.7309.4.1.5.3.2.1.1 | INTEGER | read-only | The index of the alarm variable in the DC power system controller table current alarm group. |
| INT dcPwrSysCurrAlrmIntegerValue | 1.3.6.1.4.1.7309.4.1.5.3.2.1.3 | INTEGER | read-only | The integer value of the alarm variable as reported by the DC power system controller current alarm group. |
| STR dcPwrSysCurrAlrmName | 1.3.6.1.4.1.7309.4.1.5.3.2.1.2 | DisplayString | read-only | The description of the alarm variable as reported by the DC power system controller current alarm group. |
| INT dcPwrSysCurrAlrmSeverity | 1.3.6.1.4.1.7309.4.1.5.3.2.1.5 | INTEGER | read-only | The integer value of alarm severity level of the extra variable as reported by the DC power system controller current alarm group. |
| STR dcPwrSysCurrAlrmStringValue | 1.3.6.1.4.1.7309.4.1.5.3.2.1.4 | DisplayString | read-only | The string value of the alarm variable as reported by the DC power system controller current alarm group. |
| dcPwrSysCurrAlrmTable | 1.3.6.1.4.1.7309.4.1.5.3.2 | not-accessible | A table of DC power system controller current alarm variables. | |
| dcPwrSysCurrAlrmTbl | 1.3.6.1.4.1.7309.4.1.5.3 | |||
| INT dcPwrSysCustomAlrmCount | 1.3.6.1.4.1.7309.4.1.5.7.1 | INTEGER | read-only | Number of custom alarm variables in system controller alarm table. |
| dcPwrSysCustomAlrmEntry | 1.3.6.1.4.1.7309.4.1.5.7.2.1 | not-accessible | An entry into the DC power system controller custom alarm group. | |
| INT dcPwrSysCustomAlrmIndex | 1.3.6.1.4.1.7309.4.1.5.7.2.1.1 | INTEGER | read-only | The index of the alarm variable in the DC power system controller table custom alarm group. |
| INT dcPwrSysCustomAlrmIntegerValue | 1.3.6.1.4.1.7309.4.1.5.7.2.1.3 | INTEGER | read-only | The integer value of the alarm variable as reported by the DC power system controller custom alarm group. |
| STR dcPwrSysCustomAlrmName | 1.3.6.1.4.1.7309.4.1.5.7.2.1.2 | DisplayString | read-only | The description of the alarm variable as reported by the DC power system controller custom alarm group. |
| INT dcPwrSysCustomAlrmSeverity | 1.3.6.1.4.1.7309.4.1.5.7.2.1.5 | INTEGER | read-only | The integer value of alarm severity level of the extra variable as reported by the DC power system controller custom alarm group. |
| STR dcPwrSysCustomAlrmStringValue | 1.3.6.1.4.1.7309.4.1.5.7.2.1.4 | DisplayString | read-only | The string value of the alarm variable as reported by the DC power system controller custom alarm group. |
| dcPwrSysCustomAlrmTable | 1.3.6.1.4.1.7309.4.1.5.7.2 | not-accessible | A table of DC power system controller custom alarm variables. | |
| dcPwrSysCustomAlrmTbl | 1.3.6.1.4.1.7309.4.1.5.7 | |||
| INT dcPwrSysCustomIpCount | 1.3.6.1.4.1.7309.4.1.6.4.1 | INTEGER | read-only | Number of custom input variables in system controller custom input table. |
| dcPwrSysCustomIpEntry | 1.3.6.1.4.1.7309.4.1.6.4.2.1 | not-accessible | An entry into the custom input group. | |
| INT dcPwrSysCustomIpIndex | 1.3.6.1.4.1.7309.4.1.6.4.2.1.1 | INTEGER | read-only | The index of the custom input variable in the table custom input group. |
| STR dcPwrSysCustomIpName | 1.3.6.1.4.1.7309.4.1.6.4.2.1.2 | DisplayString | read-only | The description of the custom input variable as reported by the custom input group. |
| STR dcPwrSysCustomIpStringValue | 1.3.6.1.4.1.7309.4.1.6.4.2.1.4 | DisplayString | read-only | The string value of the custom input variable as reported by the custom input group. |
| dcPwrSysCustomIpTable | 1.3.6.1.4.1.7309.4.1.6.4.2 | not-accessible | A table of digital custom variables. | |
| dcPwrSysCustomIpTbl | 1.3.6.1.4.1.7309.4.1.6.4 | |||
| dcPwrSysDevice | 1.3.6.1.4.1.7309.4.1 | |||
| INT dcPwrSysDigAlrmCount | 1.3.6.1.4.1.7309.4.1.5.2.1 | INTEGER | read-only | Number of digital alarm variables in system controller alarm table. |
| dcPwrSysDigAlrmEntry | 1.3.6.1.4.1.7309.4.1.5.2.2.1 | not-accessible | An entry into the DC power system controller digital alarm group. | |
| INT dcPwrSysDigAlrmIndex | 1.3.6.1.4.1.7309.4.1.5.2.2.1.1 | INTEGER | read-only | The index of the alarm variable in the DC power system controller table digital alarm group. |
| INT dcPwrSysDigAlrmIntegerValue | 1.3.6.1.4.1.7309.4.1.5.2.2.1.3 | INTEGER | read-only | The integer value of the alarm variable as reported by the DC power system controller digital alarm group. |
| STR dcPwrSysDigAlrmName | 1.3.6.1.4.1.7309.4.1.5.2.2.1.2 | DisplayString | read-only | The description of the alarm variable as reported by the DC power system controller digital alarm group. |
| INT dcPwrSysDigAlrmSeverity | 1.3.6.1.4.1.7309.4.1.5.2.2.1.5 | INTEGER | read-only | The integer value of alarm severity level of the extra variable as reported by the DC power system controller digital alarm group. |
| STR dcPwrSysDigAlrmStringValue | 1.3.6.1.4.1.7309.4.1.5.2.2.1.4 | DisplayString | read-only | The string value of the alarm variable as reported by the DC power system controller digital alarm group. |
| dcPwrSysDigAlrmTable | 1.3.6.1.4.1.7309.4.1.5.2.2 | not-accessible | A table of DC power system controller digital alarm variables. | |
| dcPwrSysDigAlrmTbl | 1.3.6.1.4.1.7309.4.1.5.2 | |||
| INT dcPwrSysDigIpCount | 1.3.6.1.4.1.7309.4.1.6.1.1 | INTEGER | read-only | Number of digital input variables in system controller digital input table. |
| dcPwrSysDigIpEntry | 1.3.6.1.4.1.7309.4.1.6.1.2.1 | not-accessible | An entry into the digital input group. | |
| INT dcPwrSysDigIpIndex | 1.3.6.1.4.1.7309.4.1.6.1.2.1.1 | INTEGER | read-only | The index of the digital input variable in the table digital input group. |
| INT dcPwrSysDigIpIntegerValue | 1.3.6.1.4.1.7309.4.1.6.1.2.1.3 | INTEGER | read-only | The integer value of the digital input variable as reported by the digital input group. |
| STR dcPwrSysDigIpName | 1.3.6.1.4.1.7309.4.1.6.1.2.1.2 | DisplayString | read-only | The description of the digital input variable as reported by the digital input group. |
| STR dcPwrSysDigIpStringValue | 1.3.6.1.4.1.7309.4.1.6.1.2.1.4 | DisplayString | read-only | The string value of the digital input variable as reported by the digital input group. |
| dcPwrSysDigIpTable | 1.3.6.1.4.1.7309.4.1.6.1.2 | not-accessible | A table of digital input variables. | |
| dcPwrSysDigIpTbl | 1.3.6.1.4.1.7309.4.1.6.1 | |||
| INT dcPwrSysDischargeAmps | 1.3.6.1.4.1.7309.4.1.1.4 | INTEGER | read-only | This value indicates the present load current. The integer value represent a two digit fix decimal (Value = real current * 100) in Amps. |
| INT dcPwrSysDischargeVolts | 1.3.6.1.4.1.7309.4.1.1.2 | INTEGER | read-only | This value indicates the present load voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volts. |
| INT dcPwrSysgCustomIpIntegerValue | 1.3.6.1.4.1.7309.4.1.6.4.2.1.3 | INTEGER | read-write | The integer value of the custom input variable as reported by the custom input group. |
| dcPwrSysInputsTbl | 1.3.6.1.4.1.7309.4.1.6 | |||
| INT dcPwrSysInvAlrmCount | 1.3.6.1.4.1.7309.4.1.5.12.1 | INTEGER | read-only | Number of alarm variables in system controller alarm table |
| dcPwrSysInvAlrmEntry | 1.3.6.1.4.1.7309.4.1.5.12.2.1 | not-accessible | An entry into the power system controller Inv alarm group | |
| INT dcPwrSysInvAlrmIndex | 1.3.6.1.4.1.7309.4.1.5.12.2.1.1 | INTEGER | read-only | |
| INT dcPwrSysInvAlrmIntegerValue | 1.3.6.1.4.1.7309.4.1.5.12.2.1.3 | INTEGER | read-only | |
| STR dcPwrSysInvAlrmName | 1.3.6.1.4.1.7309.4.1.5.12.2.1.2 | DisplayString | read-only | |
| INT dcPwrSysInvAlrmSeverity | 1.3.6.1.4.1.7309.4.1.5.12.2.1.5 | INTEGER | read-only | |
| STR dcPwrSysInvAlrmStringValue | 1.3.6.1.4.1.7309.4.1.5.12.2.1.4 | DisplayString | read-only | |
| dcPwrSysInvAlrmTable | 1.3.6.1.4.1.7309.4.1.5.12.2 | not-accessible | A table of power system controller Inv alarm variables | |
| dcPwrSysInvAlrmTbl | 1.3.6.1.4.1.7309.4.1.5.12 | |||
| INT dcPwrSysMajorAlarm | 1.3.6.1.4.1.7309.4.1.1.5 | INTEGER | read-only | Major Alarm |
| NTF dcPwrSysMajorAlarmActiveTrap | 1.3.6.1.4.1.7309.4.1.3.0.8 | A trap issued as a summary of DC power system status. It is sent when the system goes into in Major Alarm | ||
| NTF dcPwrSysMajorAlarmClearedTrap | 1.3.6.1.4.1.7309.4.1.3.0.9 | A trap issued as a summary of DC power system status. It is sent when the system comes out of Major Alarm | ||
| INT dcPwrSysMinorAlarm | 1.3.6.1.4.1.7309.4.1.1.6 | INTEGER | read-only | Minor Alarm |
| NTF dcPwrSysMinorAlarmActiveTrap | 1.3.6.1.4.1.7309.4.1.3.0.10 | A trap issued as a summary of DC power system status. It is sent when the system goes into in Minor Alarm | ||
| NTF dcPwrSysMinorAlarmClearedTrap | 1.3.6.1.4.1.7309.4.1.3.0.11 | A trap issued as a summary of DC power system status. It is sent when the system comes out of Minor Alarm | ||
| INT dcPwrSysMiscAlrmCount | 1.3.6.1.4.1.7309.4.1.5.8.1 | INTEGER | read-only | Number of misc alarm variables in system controller alarm table. |
| dcPwrSysMiscAlrmEntry | 1.3.6.1.4.1.7309.4.1.5.8.2.1 | not-accessible | An entry into the DC power system controller misc alarm group. | |
| INT dcPwrSysMiscAlrmIndex | 1.3.6.1.4.1.7309.4.1.5.8.2.1.1 | INTEGER | read-only | The index of the alarm variable in the DC power system controller table misc alarm group. |
| INT dcPwrSysMiscAlrmIntegerValue | 1.3.6.1.4.1.7309.4.1.5.8.2.1.3 | INTEGER | read-only | The integer value of the alarm variable as reported by the DC power system controller misc alarm group. |
| STR dcPwrSysMiscAlrmName | 1.3.6.1.4.1.7309.4.1.5.8.2.1.2 | DisplayString | read-only | The description of the alarm variable as reported by the DC power system controller misc alarm group. |
| INT dcPwrSysMiscAlrmSeverity | 1.3.6.1.4.1.7309.4.1.5.8.2.1.5 | INTEGER | read-only | The integer value of alarm severity level of the extra variable as reported by the DC power system controller misc alarm group. |
| STR dcPwrSysMiscAlrmStringValue | 1.3.6.1.4.1.7309.4.1.5.8.2.1.4 | DisplayString | read-only | The string value of the alarm variable as reported by the DC power system controller misc alarm group. |
| dcPwrSysMiscAlrmTable | 1.3.6.1.4.1.7309.4.1.5.8.2 | not-accessible | A table of DC power system controller misc alarm variables. | |
| dcPwrSysMiscAlrmTbl | 1.3.6.1.4.1.7309.4.1.5.8 | |||
| dcPwrSysOutputsTbl | 1.3.6.1.4.1.7309.4.1.4 | |||
| STR dcPwrSysPhoneNumber | 1.3.6.1.4.1.7309.4.1.2.6 | DisplayString | read-only | Phone Number |
| INT dcPwrSysRectAlrmCount | 1.3.6.1.4.1.7309.4.1.5.1.1 | INTEGER | read-only | Number of rectifier alarm variables in system controller alarm table. |
| dcPwrSysRectAlrmEntry | 1.3.6.1.4.1.7309.4.1.5.1.2.1 | not-accessible | An entry into the DC power system controller rectifier alarm group. | |
| INT dcPwrSysRectAlrmIndex | 1.3.6.1.4.1.7309.4.1.5.1.2.1.1 | INTEGER | read-only | The index of the alarm variable in the DC power system controller table rectifier alarm group. |
| INT dcPwrSysRectAlrmIntegerValue | 1.3.6.1.4.1.7309.4.1.5.1.2.1.3 | INTEGER | read-only | The integer value of the alarm variable as reported by the DC power system controller rectifier alarm group. |
| STR dcPwrSysRectAlrmName | 1.3.6.1.4.1.7309.4.1.5.1.2.1.2 | DisplayString | read-only | The description of the alarm variable as reported by the DC power system controller rectifier alarm group. |
| INT dcPwrSysRectAlrmSeverity | 1.3.6.1.4.1.7309.4.1.5.1.2.1.5 | INTEGER | read-only | The integer value of alarm severity level of the extra variable as reported by the DC power system controller rectifier alarm group. |
| STR dcPwrSysRectAlrmStringValue | 1.3.6.1.4.1.7309.4.1.5.1.2.1.4 | DisplayString | read-only | The string value of the alarm variable as reported by the DC power system controller rectifier alarm group. |
| dcPwrSysRectAlrmTable | 1.3.6.1.4.1.7309.4.1.5.1.2 | not-accessible | A table of DC power system controller rectifier alarm variables. | |
| dcPwrSysRectAlrmTbl | 1.3.6.1.4.1.7309.4.1.5.1 | |||
| INT dcPwrSysRectIpCount | 1.3.6.1.4.1.7309.4.1.6.3.1 | INTEGER | read-only | Number of rectifier input variables in system controller rectifier input table. |
| dcPwrSysRectIpEntry | 1.3.6.1.4.1.7309.4.1.6.3.2.1 | not-accessible | An entry into the rectifier input group. | |
| INT dcPwrSysRectIpIndex | 1.3.6.1.4.1.7309.4.1.6.3.2.1.1 | INTEGER | read-only | The index of the rectifier input variable in the table rectifier input group. |
| INT dcPwrSysRectIpIntegerValue | 1.3.6.1.4.1.7309.4.1.6.3.2.1.3 | INTEGER | read-only | The integer value of the rectifier input variable as reported by the rectifier input group. |
| STR dcPwrSysRectIpName | 1.3.6.1.4.1.7309.4.1.6.3.2.1.2 | DisplayString | read-only | The description of the rectifier input variable as reported by the rectifier input group. |
| STR dcPwrSysRectIpStringValue | 1.3.6.1.4.1.7309.4.1.6.3.2.1.4 | DisplayString | read-only | The string value of the rectifier input variable as reported by the rectifier input group. |
| dcPwrSysRectIpTable | 1.3.6.1.4.1.7309.4.1.6.3.2 | not-accessible | A table of rectifier input variables. | |
| dcPwrSysRectIpTbl | 1.3.6.1.4.1.7309.4.1.6.3 | |||
| INT dcPwrSysRelayCount | 1.3.6.1.4.1.7309.4.1.4.1.1 | INTEGER | read-only | Number of relay variables in system controller relay table. |
| dcPwrSysRelayEntry | 1.3.6.1.4.1.7309.4.1.4.1.2.1 | not-accessible | An entry into the DC power system controller relay output group. | |
| INT dcPwrSysRelayIndex | 1.3.6.1.4.1.7309.4.1.4.1.2.1.1 | INTEGER | read-only | The index of the relay variable in the power system controller relay output group. |
| INT dcPwrSysRelayIntegerValue | 1.3.6.1.4.1.7309.4.1.4.1.2.1.3 | INTEGER | read-only | The integer value of the relay variable as reported by the DC power system controller relay output group. |
| STR dcPwrSysRelayName | 1.3.6.1.4.1.7309.4.1.4.1.2.1.2 | DisplayString | read-only | The description of the relay variable as reported by the DC power system controller relay output group. |
| INT dcPwrSysRelaySeverity | 1.3.6.1.4.1.7309.4.1.4.1.2.1.5 | INTEGER | read-only | The integer value of relay severity level of the extra variable as reported by the DC power system controller relay output group. |
| STR dcPwrSysRelayStringValue | 1.3.6.1.4.1.7309.4.1.4.1.2.1.4 | DisplayString | read-only | The string value of the relay variable as reported by the DC power system controller relay output group. |
| dcPwrSysRelayTable | 1.3.6.1.4.1.7309.4.1.4.1.2 | not-accessible | A table of DC power system controller rectifier relay output variables. | |
| dcPwrSysRelayTbl | 1.3.6.1.4.1.7309.4.1.4.1 | |||
| NTF dcPwrSysRelayTrap | 1.3.6.1.4.1.7309.4.1.3.0.3 | A trap issued from a change in state in one of the relays on the DC power system controller. | ||
| INT dcPwrSysResyncAlarms | 1.3.6.1.4.1.7309.4.1.8.1 | INTEGER | read-write | Send/Resend all active alarms that were previously sent through SNMP notification. |
| STR dcPwrSysSiteCity | 1.3.6.1.4.1.7309.4.1.2.2 | DisplayString | read-only | Site City |
| STR dcPwrSysSiteCountry | 1.3.6.1.4.1.7309.4.1.2.4 | DisplayString | read-only | Site Country |
| STR dcPwrSysSiteName | 1.3.6.1.4.1.7309.4.1.2.1 | DisplayString | read-only | Site Name |
| STR dcPwrSysSiteNumber | 1.3.6.1.4.1.7309.4.1.2.7 | DisplayString | read-only | Site Number |
| STR dcPwrSysSiteRegion | 1.3.6.1.4.1.7309.4.1.2.3 | DisplayString | read-only | Site Region |
| STR dcPwrSysSoftwareTimestamp | 1.3.6.1.4.1.7309.4.1.2.12 | DisplayString | read-only | The time stamp of the software running on the monitored system. |
| STR dcPwrSysSoftwareVersion | 1.3.6.1.4.1.7309.4.1.2.11 | DisplayString | read-only | The version of software running on the monitored system. |
| dcPwrSysString | 1.3.6.1.4.1.7309.4.1.2 | |||
| STR dcPwrSysSystemNumber | 1.3.6.1.4.1.7309.4.1.2.10 | DisplayString | read-only | The number of the monitored system. |
| STR dcPwrSysSystemSerial | 1.3.6.1.4.1.7309.4.1.2.9 | DisplayString | read-only | The serial number of the monitored system. |
| STR dcPwrSysSystemType | 1.3.6.1.4.1.7309.4.1.2.8 | DisplayString | read-only | The type of system being monitored by the agent. |
| INT dcPwrSysTempAlrmCount | 1.3.6.1.4.1.7309.4.1.5.6.1 | INTEGER | read-only | Number of temperature alarm variables in system controller alarm table. |
| dcPwrSysTempAlrmEntry | 1.3.6.1.4.1.7309.4.1.5.6.2.1 | not-accessible | An entry into the DC power system controller temperature alarm group. | |
| INT dcPwrSysTempAlrmIndex | 1.3.6.1.4.1.7309.4.1.5.6.2.1.1 | INTEGER | read-only | The index of the alarm variable in the DC power system controller table temperature alarm group. |
| INT dcPwrSysTempAlrmIntegerValue | 1.3.6.1.4.1.7309.4.1.5.6.2.1.3 | INTEGER | read-only | The integer value of the alarm variable as reported by the DC power system controller temperature alarm group. |
| STR dcPwrSysTempAlrmName | 1.3.6.1.4.1.7309.4.1.5.6.2.1.2 | DisplayString | read-only | The description of the alarm variable as reported by the DC power system controller temperature alarm group. |
| INT dcPwrSysTempAlrmSeverity | 1.3.6.1.4.1.7309.4.1.5.6.2.1.5 | INTEGER | read-only | The integer value of alarm severity level of the extra variable as reported by the DC power system controller temperature alarm group. |
| STR dcPwrSysTempAlrmStringValue | 1.3.6.1.4.1.7309.4.1.5.6.2.1.4 | DisplayString | read-only | The string value of the alarm variable as reported by the DC power system controller temperature alarm group. |
| dcPwrSysTempAlrmTable | 1.3.6.1.4.1.7309.4.1.5.6.2 | not-accessible | A table of DC power system controller temperature alarm variables. | |
| dcPwrSysTempAlrmTbl | 1.3.6.1.4.1.7309.4.1.5.6 | |||
| INT dcPwrSysTimerIpCount | 1.3.6.1.4.1.7309.4.1.6.6.1 | INTEGER | read-only | Number of Timer input variables in system controller Timer input table. |
| dcPwrSysTimerIpEntry | 1.3.6.1.4.1.7309.4.1.6.6.2.1 | not-accessible | An entry into the Timer input group | |
| INT dcPwrSysTimerIpIndex | 1.3.6.1.4.1.7309.4.1.6.6.2.1.1 | INTEGER | read-only | The index of the Timer input variable in the table Timer input group. |
| INT dcPwrSysTimerIpIntegerValue | 1.3.6.1.4.1.7309.4.1.6.6.2.1.3 | INTEGER | read-only | The integer value of the Timer input variable as reported by the Timer input group. |
| STR dcPwrSysTimerIpName | 1.3.6.1.4.1.7309.4.1.6.6.2.1.2 | DisplayString | read-only | The description of the Timer input variable as reported by the Timer input group. |
| STR dcPwrSysTimerIpStringValue | 1.3.6.1.4.1.7309.4.1.6.6.2.1.4 | DisplayString | read-only | The string value of the Timer input variable as reported by the Timer input group. |
| dcPwrSysTimerIpTable | 1.3.6.1.4.1.7309.4.1.6.6.2 | not-accessible | A table of Timer input variables | |
| dcPwrSysTimerIpTbl | 1.3.6.1.4.1.7309.4.1.6.6 | |||
| STR dcPwrSysTimeStamp | 1.3.6.1.4.1.7309.4.1.9.2 | DisplayString | read-only | |
| dcPwrSysTrap | 1.3.6.1.4.1.7309.4.1.3.0 | |||
| dcPwrSysTraps | 1.3.6.1.4.1.7309.4.1.3 | |||
| dcPwrSysVariable | 1.3.6.1.4.1.7309.4.1.1 | |||
| INT dcPwrSysVoltAlrmCount | 1.3.6.1.4.1.7309.4.1.5.4.1 | INTEGER | read-only | Number of voltage alarm variables in system controller alarm table. |
| dcPwrSysVoltAlrmEntry | 1.3.6.1.4.1.7309.4.1.5.4.2.1 | not-accessible | An entry into the DC power system controller voltage alarm group. | |
| INT dcPwrSysVoltAlrmIndex | 1.3.6.1.4.1.7309.4.1.5.4.2.1.1 | INTEGER | read-only | The index of the alarm variable in the DC power system controller table voltage alarm group. |
| INT dcPwrSysVoltAlrmIntegerValue | 1.3.6.1.4.1.7309.4.1.5.4.2.1.3 | INTEGER | read-only | The integer value of the alarm variable as reported by the DC power system controller voltage alarm group. |
| STR dcPwrSysVoltAlrmName | 1.3.6.1.4.1.7309.4.1.5.4.2.1.2 | DisplayString | read-only | The description of the alarm variable as reported by the DC power system controller voltage alarm group. |
| INT dcPwrSysVoltAlrmSeverity | 1.3.6.1.4.1.7309.4.1.5.4.2.1.5 | INTEGER | read-only | The integer value of alarm severity level of the extra variable as reported by the DC power system controller voltage alarm group. |
| STR dcPwrSysVoltAlrmStringValue | 1.3.6.1.4.1.7309.4.1.5.4.2.1.4 | DisplayString | read-only | The string value of the alarm variable as reported by the DC power system controller voltage alarm group. |
| dcPwrSysVoltAlrmTable | 1.3.6.1.4.1.7309.4.1.5.4.2 | not-accessible | A table of DC power system controller voltage alarm variables. | |
| dcPwrSysVoltAlrmTbl | 1.3.6.1.4.1.7309.4.1.5.4 | |||
| dcPwrVarbindNameReference | 1.3.6.1.4.1.7309.4.1.9 |
RFC description
Manages Alpha DC power system controllers for monitoring rectifier, battery, and alarm status.
Start monitoring Alpha Technologies DC power systems with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.