| OID symbolic | OID numeric | Type | Access | Description |
| BOO ibmSystemFanActiveCooling | 1.3.6.1.4.1.2.6.159.1.1.80.3.1.4 | Boolean | read-only | States if this fan supports active cooling [True | False] |
| STR ibmSystemFanDesiredSpeed | 1.3.6.1.4.1.2.6.159.1.1.80.3.1.3 | String | read-only | The desired speed in revolutions per minute for this fan |
| ibmSystemFanEntry | 1.3.6.1.4.1.2.6.159.1.1.80.3.1 | | not-accessible | A sequence of fan sensor readings |
| BOO ibmSystemFanEventAutoClearEnabled | 1.3.6.1.4.1.2.6.159.1.1.80.3.1.8 | Boolean | read-only | False means that events are only generated on state changes. True
means that events are generated on state changes and periodically
when the object is in a non-normal state. |
| BOO ibmSystemFanEventsEnabled | 1.3.6.1.4.1.2.6.159.1.1.80.3.1.6 | Boolean | read-only | Event generation status. [True | False] |
| NUM ibmSystemFanFanType | 1.3.6.1.4.1.2.6.159.1.1.80.3.1.5 | Uint32 | read-only | The current fan type. |
| STR ibmSystemFanKeyIndex | 1.3.6.1.4.1.2.6.159.1.1.80.3.1.1 | String | read-only | The index used by this table |
| NUM ibmSystemFanPollingInterval | 1.3.6.1.4.1.2.6.159.1.1.80.3.1.7 | Uint64 | read-only | Polling interval is measured in seconds. Value of zero indicates
do it once and quit. Minimum polling interval is ten seconds. |
| STR ibmSystemFanStatus | 1.3.6.1.4.1.2.6.159.1.1.80.3.1.9 | String | read-only | The Status property is a string indicating the current
status of the object. Various operational and non-operational
statuses can be defined. Operational statuses are OK, Degraded
and Pred Fail. Pred Fail indicates that an element may be
functioning properly but predicting a failure in the near
future. An example is a SMART-enabled hard drive. Non-operational
statuses can also be specified. These are Error, Starting,
Stopping and Service. The latter, Service, could apply during
mirror-resilvering of a disk, reload of a user permissions list,
or other administrative work. Not all such work is on-line, yet
the managed element is neither OK nor in one of the other states.
OK = Normal
Error = Critical |
| ibmSystemFanTable | 1.3.6.1.4.1.2.6.159.1.1.80.3 | | not-accessible | The IBMPSG_Fan class represents an IBM managed fan sensor. |
| BOO ibmSystemFanVariableSpeed | 1.3.6.1.4.1.2.6.159.1.1.80.3.1.2 | Boolean | read-only | States if this fan supports variable speeds [True | False] |
| NUM ibmSystemSystemEnclosureACLineStatus | 1.3.6.1.4.1.2.6.159.1.1.80.4.1.7 | Uint16 | read-only | This group defines status information about the AC line in the notebook |
| NUM ibmSystemSystemEnclosureDockingStatus | 1.3.6.1.4.1.2.6.159.1.1.80.4.1.6 | Uint16 | read-only | This defines whether system is docked or not |
| ibmSystemSystemEnclosureEntry | 1.3.6.1.4.1.2.6.159.1.1.80.4.1 | | not-accessible | A sequence of enclosure readings |
| BOO ibmSystemSystemEnclosureEventAutoClearEnabled | 1.3.6.1.4.1.2.6.159.1.1.80.4.1.8 | Boolean | read-only | False means that events are only generated on state changes. True
means that events are generated on state changes and periodically
when the object is in a non-normal state. [True | False] |
| BOO ibmSystemSystemEnclosureEventsEnabled | 1.3.6.1.4.1.2.6.159.1.1.80.4.1.4 | Boolean | read-only | Event generation enabled status. [True | False] |
| NUM ibmSystemSystemEnclosureIntrusionStatus | 1.3.6.1.4.1.2.6.159.1.1.80.4.1.2 | Uint32 | read-only | The intrusion status |
| NUM ibmSystemSystemEnclosureIntrusionType | 1.3.6.1.4.1.2.6.159.1.1.80.4.1.3 | Uint32 | read-only | The intrusion type |
| STR ibmSystemSystemEnclosureKeyIndex | 1.3.6.1.4.1.2.6.159.1.1.80.4.1.1 | String | read-only | The index used by this table |
| NUM ibmSystemSystemEnclosurePollingInterval | 1.3.6.1.4.1.2.6.159.1.1.80.4.1.5 | Uint64 | read-only | Polling interval is measured in seconds. Value of zero indicates
do it once and quit. Minimum polling interval is ten seconds. |
| STR ibmSystemSystemEnclosureStatus | 1.3.6.1.4.1.2.6.159.1.1.80.4.1.9 | String | read-only | The Status property is a string indicating the current status of
the object. Various operational and non-operational statuses can
be defined. Operational statuses are OK, Degraded and Pred Fail.
Pred Fail indicates that an element may be functioning properly
but predicting a failure in the near future. An example is a
SMART-enabled hard drive. Non-operational statuses can also be
specified. These are Error, Starting, Stopping and Service. The
latter, Service, could apply during mirror-resilvering of a disk,
reload of a user permissions list, or other administrative work.
Not all such work is on-line, yet the managed element is neither
OK nor in one of the other states.
OK = Normal
Error = Critical |
| ibmSystemSystemEnclosureTable | 1.3.6.1.4.1.2.6.159.1.1.80.4 | | not-accessible | The IBMPSG_SystemEnclosure class represents an IBM chassis sensor. |
| NUM ibmSystemTachometerCurrentReading | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.2 | Sint32 | read-only | The current fan reading in revolutions per minute for this sensor |
| ibmSystemTachometerEntry | 1.3.6.1.4.1.2.6.159.1.1.80.5.1 | | not-accessible | A sequence of fan enclosure readings |
| BOO ibmSystemTachometerEventAutoClearEnabled | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.19 | Boolean | read-only | False means that events are only generated on state changes. True means
that events are generated on state changes and periodically when the
object is in a non-normal state. |
| BOO ibmSystemTachometerEventsEnabled | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.18 | Boolean | read-only | Event generation status. |
| NUM ibmSystemTachometerFanDescrip | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.16 | Uint32 | read-only | The Fan Description. |
| NUM ibmSystemTachometerFanType | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.17 | Uint32 | read-only | The current fan type. |
| STR ibmSystemTachometerKeyIndex | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.1 | String | read-only | The index used by this table |
| NUM ibmSystemTachometerLowerThresholdCritical | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.12 | Sint32 | read-only | The critical lower threshold fan reading in revolutions per minute for this sensor |
| NUM ibmSystemTachometerLowerThresholdFatal | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.14 | Sint32 | read-only | The fatal lower threshold fan reading in revolutions per minute for this sensor |
| NUM ibmSystemTachometerLowerThresholdNonCritical | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.10 | Sint32 | read-only | The non-critical lower threshold fan reading in revolutions per minute for this sensor |
| NUM ibmSystemTachometerMaxReadable | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.6 | Sint32 | read-only | The maximum readable fan reading in revolutions per minute for this sensor |
| NUM ibmSystemTachometerMinReadable | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.7 | Sint32 | read-only | The minimum readable fan reading in revolutions per minute for this sensor |
| NUM ibmSystemTachometerNominalReading | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.3 | Sint32 | read-only | The nominal fan reading in revolutions per minute for this sensor |
| NUM ibmSystemTachometerNormalMax | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.4 | Sint32 | read-only | The normal maximum fan reading in revolutions per minute for this sensor |
| NUM ibmSystemTachometerNormalMin | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.5 | Sint32 | read-only | The normal minimum fan reading in revolutions per minute for this sensor |
| NUM ibmSystemTachometerResolution | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.8 | Uint32 | read-only | The resolution of this fan reading in revolutions per minute for this sensor |
| STR ibmSystemTachometerStatus | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.20 | String | read-only | The Status property is a string indicating the current status of the
object. Various operational and non-operational statuses can be defined.
Operational statuses are OK, Degraded and Pred Fail. Pred Fail indicates
that an element may be functioning properly but predicting a failure in
the near future. An example is a SMART-enabled hard drive. Non-operational
statuses can also be specified. These are Error, Starting, Stopping and
Service. The latter, Service, could apply during mirror-resilvering of a
disk, reload of a user permissions list, or other administrative work. Not
all such work is on-line, yet the managed element is neither OK nor in one
of the other states.
OK = Normal
Error = Critical |
| ibmSystemTachometerTable | 1.3.6.1.4.1.2.6.159.1.1.80.5 | | not-accessible | The IBMPSG_Tachometer class represents an IBM managed Fan speed Sensor. |
| NUM ibmSystemTachometerTolerance | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.9 | Sint32 | read-only | The tolerance of this fan reading in revolutions per minute for this sensor |
| NUM ibmSystemTachometerUpperThresholdCritical | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.13 | Sint32 | read-only | The critical upper threshold fan reading in revolutions per minute for this sensor |
| NUM ibmSystemTachometerUpperThresholdFatal | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.15 | Sint32 | read-only | The fatal upper threshold fan reading in revolutions per minute for this sensor |
| NUM ibmSystemTachometerUpperThresholdNonCritical | 1.3.6.1.4.1.2.6.159.1.1.80.5.1.11 | Sint32 | read-only | The non-critical upper threshold fan reading in revolutions per minute for this sensor |
| NUM ibmSystemTemperatureSensorAccuracy | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.10 | Sint32 | read-only | The degree of accuracy in Celcius of the temperature reading for this sensor |
| NUM ibmSystemTemperatureSensorCurrentReading | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.2 | Sint32 | read-only | The current Celcius temperature reading for this sensor |
| ibmSystemTemperatureSensorEntry | 1.3.6.1.4.1.2.6.159.1.1.80.1.1 | | not-accessible | A sequence of temperature sensor entries |
| BOO ibmSystemTemperatureSensorEventAutoClearEnabled | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.20 | Boolean | read-only | False means that events are only generated on state changes.
True means that events are generated on state changes and
periodically when the object is in a non-normal state. |
| BOO ibmSystemTemperatureSensorEventsEnabled | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.18 | Boolean | read-only | Event generation status [True | False] |
| STR ibmSystemTemperatureSensorKeyIndex | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.1 | String | read-only | The index used by this table |
| NUM ibmSystemTemperatureSensorLowerThresholdCritical | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.13 | Sint32 | read-only | The lower critical threshold in Celcius for this sensor |
| NUM ibmSystemTemperatureSensorLowerThresholdFatal | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.15 | Sint32 | read-only | The lower fatal threshold in Celcius for this sensor |
| NUM ibmSystemTemperatureSensorLowerThresholdNonCritical | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.11 | Sint32 | read-only | The lower non-critical threshold in Celcius for this sensor |
| NUM ibmSystemTemperatureSensorMaxReadable | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.6 | Sint32 | read-only | The maximum readable Celcius temperature reading for this sensor |
| NUM ibmSystemTemperatureSensorMinReadable | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.7 | Sint32 | read-only | The minimum readalbe Celcius temperature reading for this sensor |
| NUM ibmSystemTemperatureSensorNominalReading | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.3 | Sint32 | read-only | The nominal Celcius temperature reading for this sensor |
| NUM ibmSystemTemperatureSensorNormalMax | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.4 | Sint32 | read-only | The normal maximum Celcius temperature reading for this sensor |
| NUM ibmSystemTemperatureSensorNormalMin | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.5 | Sint32 | read-only | The normal minimum Celcius temperature reading for this sensor |
| NUM ibmSystemTemperatureSensorPollingInterval | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.19 | Uint64 | read-only | Polling interval is measured in seconds. Value of zero
indicates do it once and quit. Minimum polling interval
is ten seconds. |
| NUM ibmSystemTemperatureSensorResolution | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.8 | Uint32 | read-only | The resolution in Celcius of the temperature reading for this sensor |
| STR ibmSystemTemperatureSensorStatus | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.21 | String | read-only | The Status property is a string indicating the current status
of the object. Various operational and non-operational statuses
can be defined. Operational statuses are OK, Degraded and Pred
Fail. Pred Fail indicates that an element may be functioning
properly but predicting a failure in the near future. An example
is a SMART-enabled hard drive. Non-operational statuses can also
be specified. These are Error, Starting, Stopping and Service.
The latter, Service, could apply during mirror-resilvering of a
disk, reload of a user permissions list, or other administrative
work. Not all such work is on-line, yet the managed element is
neither OK nor in one of the other states.
Ok = Normal
Error = Critical |
| ibmSystemTemperatureSensorTable | 1.3.6.1.4.1.2.6.159.1.1.80.1 | | not-accessible | The IBMPSG_TemperatureSensor class represents an IBM managed Temperature Sensor. |
| NUM ibmSystemTemperatureSensorTempLocation | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.17 | Uint32 | read-only | The current temperature sensor location |
| NUM ibmSystemTemperatureSensorTolerance | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.9 | Sint32 | read-only | The tolerance in Celcius of the temperature reading for this sensor |
| NUM ibmSystemTemperatureSensorUpperThresholdCritical | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.14 | Sint32 | read-only | The upper critical threshold in Celcius for this sensor |
| NUM ibmSystemTemperatureSensorUpperThresholdFatal | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.16 | Sint32 | read-only | The upper fatal threshold in Celcius for this sensor |
| NUM ibmSystemTemperatureSensorUpperThresholdNonCritical | 1.3.6.1.4.1.2.6.159.1.1.80.1.1.12 | Sint32 | read-only | The upper non-critical threshold in Celcius for this sensor |
| NUM ibmSystemVoltageSensorAccuracy | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.10 | Sint32 | read-only | The accuracy of the voltage reading for this sensor |
| NUM ibmSystemVoltageSensorCurrentReading | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.2 | Sint32 | read-only | The current voltage reading for this sensor |
| ibmSystemVoltageSensorEntry | 1.3.6.1.4.1.2.6.159.1.1.80.2.1 | | not-accessible | A sequence of voltage sensor readings |
| BOO ibmSystemVoltageSensorEventAutoClearEnabled | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.20 | Boolean | read-only | False means that events are only generated on state changes.
True means that events are generated on state changes and
periodically when the object is in a non-normal state. [True | False] |
| BOO ibmSystemVoltageSensorEventsEnabled | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.18 | Boolean | read-only | Event generation status. [True | False] |
| STR ibmSystemVoltageSensorKeyIndex | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.1 | String | read-only | The index used by this table |
| NUM ibmSystemVoltageSensorLowerThresholdCritical | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.13 | Sint32 | read-only | The critical lower threshold voltage reading for this sensor |
| NUM ibmSystemVoltageSensorLowerThresholdFatal | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.15 | Sint32 | read-only | The fatal lower threshold voltage reading for this sensor |
| NUM ibmSystemVoltageSensorLowerThresholdNonCritical | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.11 | Sint32 | read-only | The non-critical lower threshold voltage reading for this sensor |
| NUM ibmSystemVoltageSensorMaxReadable | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.6 | Sint32 | read-only | The maximum voltage reading for this sensor |
| NUM ibmSystemVoltageSensorMinReadable | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.7 | Sint32 | read-only | The minimum voltage reading for this sensor |
| NUM ibmSystemVoltageSensorNominalReading | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.3 | Sint32 | read-only | The nominal voltage reading for this sensor |
| NUM ibmSystemVoltageSensorNormalMax | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.4 | Sint32 | read-only | The normal maximum voltage reading for this sensor |
| NUM ibmSystemVoltageSensorNormalMin | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.5 | Sint32 | read-only | The normal minimum voltage reading for this sensor |
| NUM ibmSystemVoltageSensorPollingInterval | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.19 | Uint64 | read-only | Polling interval is measured in seconds. Value of zero
indicates do it once and quit. Minimum polling interval
is ten seconds. |
| NUM ibmSystemVoltageSensorResolution | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.8 | Uint32 | read-only | The resolution of the voltage reading for this sensor |
| STR ibmSystemVoltageSensorStatus | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.21 | String | read-only | The Status property is a string indicating the current status
of the object. Various operational and non-operational statuses
can be defined. Operational statuses are OK, Degraded and Pred
Fail. Pred Fail indicates that an element may be functioning
properly but predicting a failure in the near future. An example
is a SMART-enabled hard drive. Non-operational statuses can also
be specified. These are Error, Starting, Stopping and Service.
The latter, Service, could apply during mirror-resilvering of a
disk, reload of a user permissions list, or other administrative
work. Not all such work is on-line, yet the managed element is
neither OK nor in one of the other states.
OK = Normal
Error = Critical |
| ibmSystemVoltageSensorTable | 1.3.6.1.4.1.2.6.159.1.1.80.2 | | not-accessible | The IBMPSG_VoltageSensor class represents an IBM managed voltage Sensor. |
| NUM ibmSystemVoltageSensorTolerance | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.9 | Sint32 | read-only | The tolerance of the voltage reading for this sensor |
| NUM ibmSystemVoltageSensorUpperThresholdCritical | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.14 | Sint32 | read-only | The non-critical upper threshold voltage reading for this sensor |
| NUM ibmSystemVoltageSensorUpperThresholdFatal | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.16 | Sint32 | read-only | The fatal upper threshold voltage reading for this sensor |
| NUM ibmSystemVoltageSensorUpperThresholdNonCritical | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.12 | Sint32 | read-only | The non-critical upper threshold voltage reading for this sensor |
| NUM ibmSystemVoltageSensorVoltageType | 1.3.6.1.4.1.2.6.159.1.1.80.2.1.17 | Uint32 | read-only | The Voltage Description |