All MIBs › CME-MIB
Category: Cisco Devices, Telephony and VoIP, Vendor: Cisco Devices
Description: Manages Cisco Communications Manager Express (CME) telephony service and IP phone configuration.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CME-MIB?
CME-MIB is a Cisco MIB associated with Cisco Communications Manager Express (CME), a router-hosted IP telephony service, though its sample objects here reflect Smart Call Home / support-integration configuration (serviceAdvisor, serviceSupportCenter, contactInformation, httpProxyConfig, callHomeExclusionEvents) rather than call-processing data. It exposes configuration data for how the device registers with Cisco's support/diagnostics services -- which service advisor and support center to use, administrative contact details, and outbound HTTP proxy settings for reaching Cisco's backend. Its monitoring relevance is on the software/service-status side: httpProxyConfig determines whether the device can actually reach Cisco's Call-Home infrastructure to deliver automated fault diagnostics, and callHomeExclusionEvents controls which event types are suppressed from automatic support notifications, directly shaping what fault information gets reported. It is closely tied to Cisco's broader Smart Call Home framework (alongside MIBs such as CISCO-CALLHOME-MIB) and to Cisco IOS voice/CME feature configuration generally. It is deployed on Cisco CME-capable routers/gateways in small-to-midsize branch office telephony deployments, where CME-MIB SNMP monitoring confirms automated vendor support notifications are correctly configured.
IPNetwork Monitor allows you to monitor SNMP objects defined in CME-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Cisco Communications Manager Express (CME) router/gateway
- Cisco IOS voice-enabled router
Monitoring Examples
An admin would check httpProxyConfig to confirm the CME router can reach Cisco's Smart Call Home backend through the corporate proxy, since a misconfigured proxy would silently prevent automated diagnostic reports from being delivered. serviceAdvisor and serviceSupportCenter identify which Cisco support service the device is registered with, and contactInformation holds the registered administrative contact used in any generated support case. callHomeExclusionEvents lets the admin suppress specific noisy event types from generating automatic Call-Home reports, which would otherwise flood the support channel.
What Can Be Monitored
- Call-Home/service-advisor registration configuration
- support center assignment
- administrative contact information
- HTTP proxy configuration for diagnostics reporting
- excluded call-home event types
This MIB depends on
Related MIBs
Imported Objects
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| INT acceptLicenseAgreement | 1.3.6.1.4.1.2.3.51.2.23.4.1.1 | INTEGER | read-write | Accept Terms and Conditions of MM Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to IBM support personnel. If MM configuration is reset to defaults, the user will have to accept the terms and conditions again before they can enable Service Advisor. A GET of this object may return disabled(0) or enabled(1), depending upon the current state. However, only enabled(1) is accepted on a SET in order to accept the license agreement. A SET of disabled(0) will return noSuchValue and is not allowed. |
| INT accountSecurityLevel | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.1 | INTEGER | read-write | The level of security needed for local user login passwords. The legacy level: - no password required - no password expiration - no password re-use restrictions - no frequency of password change restrictions - account is locked for 2 minutes after 5 login failures - simple password rules - no account inactivity monitoring The high level: - password required - factory default 'USERID' account password must be changed on next login - force user to change password on first login - password expires in 90 days - password re-use checking enabled (last 5 passwords kept in history) - minimum 24 hours interval between password changes - account is locked for 60 minutes after 5 login failures - complex password rules with 2 degrees of difference from previous password - alert on account inactivity after 120 days - accounts disabled after 180 days of inactivity The custom level: - set the password settings individually under customSecuritySettings The default value is legacy. |
| accountSecurityManagement | 1.3.6.1.4.1.2.3.51.2.4.1.1.20 | |||
| INT acousticMode | 1.3.6.1.4.1.2.3.51.2.22.1.7.2.3 | INTEGER | read-write | Acoustic mode setting for thermal conditions. A setting of disabled (0), disables this feature. A setting of acoustic-quiet-level1 (5) is the least restrictive and the least quiet sound level. A setting of acoustic-quiet-level5 (1) is the most restrictive and the most quiet sound level. Some values may not be valid on some chassis. A bad value will be returned in this case. |
| INT activateNetworkUpdates | 1.3.6.1.4.1.2.3.51.2.4.9.1.16 | INTEGER | read-write | When read, the return value indicates if there are any pending network updates ready to be applied. Writing any value will apply any pending network updates immediately. |
| INT activityLogAcknowledge | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.3 | INTEGER | read-write | The acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of the issue. Checking the acknowledge flag will not cause the event to be removed from the log. This log is not cleared, so the acknowledge flag can be used to indicate a problem can be ignored. This field can be also used to override the 120 hour (5 day) filtering of reports via FTP/TFTP Server of Service Data. |
| OCT activityLogAttribute | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.4 | OCTET STRING | read-only | A string of data detailing one Activity Log entry's attribute. Status PENDING indicates that the system is preparing for the event to be called home by collecting data about the systems state. A SUCCESS state indicates that the problem was successfully transmitted to FTP/TFTP Server. The FAILED state indicates that the attempt to transmit the event information was not successful. Additional information may be found in the Event Log. The event ID, event source , date and time are all information from the original entry in the event log. The acknowledged as corrected field is a reminder to certain events to indicate their awareness of the issue. |
| activityLogEntry | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1 | not-accessible | Activity Log table entry. Each entry has the result of the FTP/TFTP Server attempt, the event ID, event source, date and time that event occured, and a text message. | |
| INT activityLogIndex | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.1 | INTEGER | read-only | The Activity Log index number. For consistent results, view as a table and not as individual entries. |
| activityLogs | 1.3.6.1.4.1.2.3.51.2.23.4.5 | |||
| OCT activityLogString | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.2 | OCTET STRING | read-only | A string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and not as individual entries. |
| activityLogTable | 1.3.6.1.4.1.2.3.51.2.23.4.5.1 | not-accessible | Table of Service Advisor Activity Log entries information. This table displays the last five events that were generated by the system or user that are called home. The entries are displayed in reverse chronological order (most recent call home entry first). For any events that happen with same Date/Time, only one event will be called home. If a call home event that is already in the activity log is triggered again on the same event source, it will not be called home again unless the prior entry has been acknowledged as corrected or 120 hours (5 days) have passed since it initially occurred and was called home. | |
| OCT addCallHomeExclusionEvent | 1.3.6.1.4.1.2.3.51.2.23.6.2 | OCTET STRING | read-write | Add one call home Event ID into the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. An Event can not be added into the exclusion list if autoFtpMode is disabled. If Service Advisor Terms and Conditions are accepted, an event can be added into the exclusion list. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| OCT address | 1.3.6.1.4.1.2.3.51.2.23.4.3.5 | OCTET STRING | read-write | The address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. 1-30 characters. |
| INT advancedFailover | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.15 | INTEGER | read-write | User can enable advanced failover. off : no standby network interface ipswap: Standby network interface, swap IPs during failover ipnoswap: Standby network interface, do not swap IPs during failover. NOTE: This MIB object is only applicable to systems with a standby MM. |
| airFilter | 1.3.6.1.4.1.2.3.51.2.2.22 | |||
| OCT altContactName | 1.3.6.1.4.1.2.3.51.2.23.4.3.10 | OCTET STRING | read-write | The name of the alternate contact person.1-30 characters. |
| OCT altEmailAddress | 1.3.6.1.4.1.2.3.51.2.23.4.3.13 | OCTET STRING | read-write | The email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (130 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters. |
| OCT altPhoneNumber | 1.3.6.1.4.1.2.3.51.2.23.4.3.11 | OCTET STRING | read-write | The phone of the alternate contact person. 5-30 characters. |
| OCT altPhoneNumberExt | 1.3.6.1.4.1.2.3.51.2.23.4.3.12 | OCTET STRING | read-write | The phone number extension of the alternate contact person. 1-30 characters. |
| ambientTemp | 1.3.6.1.4.1.2.3.51.2.2.1.5 | |||
| INT attachmentsToEmailAlerts | 1.3.6.1.4.1.2.3.51.2.4.9.3.3.2 | INTEGER | read-write | Indicates if the service information should be attached to an email alert. |
| INT authenticationLoggingTimeout | 1.3.6.1.4.1.2.3.51.2.4.1.1.10 | INTEGER | read-write | Use this option to set how long, in seconds, MM will not log the authentication events for the same user. The default setting is 5 minutes. 0 indicates log all authentication events, 255 indicates don't log any new authentication events. |
| autoCallHomeSetup | 1.3.6.1.4.1.2.3.51.2.23.4.1 | |||
| OCT autoFTPCallAddr | 1.3.6.1.4.1.2.3.51.2.23.5.2 | OCTET STRING | read-write | This field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address. |
| INT autoFTPCallMode | 1.3.6.1.4.1.2.3.51.2.23.5.1 | INTEGER | read-write | This field specifies the automated problem reporting mode. Automated problem reporting mode allows the MM to automatically put service data to a specified server when a call home event is detected. For any call home events that happen with same Date/Time, only one event will be reported. The system will also wait for an interval of 120 hours (5 days) before another identical event can be sent for the same failed component. |
| OCT autoFTPCallPassword | 1.3.6.1.4.1.2.3.51.2.23.5.5 | OCTET STRING | read-write | This field specifies the password to login remote FTP server. |
| INT autoFTPCallPort | 1.3.6.1.4.1.2.3.51.2.23.5.3 | INTEGER | read-write | This field specifies the port on remote FTP/TFTP server for data transmission. |
| OCT autoFTPCallUserID | 1.3.6.1.4.1.2.3.51.2.23.5.4 | OCTET STRING | read-write | This field specifies the user account to login remote FTP server. |
| autoFTPSetup | 1.3.6.1.4.1.2.3.51.2.23.5 | |||
| backupRestore | 1.3.6.1.4.1.2.3.51.2.22.42 | |||
| INT backupRestoreAction | 1.3.6.1.4.1.2.3.51.2.22.42.1 | INTEGER | read-write | Starts the backup or restore operation. It is intended to be write-only. NOTE: This function is only available for SNMPv3. |
| INT backupRestoreLogPush | 1.3.6.1.4.1.2.3.51.2.22.42.7 | INTEGER | read-write | Causes the restore operation to push the log to the URI address. NOTE: This can be used when restoring without restarting. NOTE: This function is only available for SNMPv3. |
| OCT backupRestoreLogURI | 1.3.6.1.4.1.2.3.51.2.22.42.6 | OCTET STRING | read-write | Indicates the URI address where the log file will be put. It will be used only if the backupRestoreLogPush will be set on push. Contains the fully qualified remote location of the file. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the packet file will reside, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The MM currently supports the following protocols: TFTP, FTP, HTTP and HTTPS. The complete format of a fully qualified remote location is: ://@/ An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp/restore.log where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the packet file is /tmp/restore.log. Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be::///. Note: When using SFTP, only an RSA fingerprint is supported. An example of a qualified location can be: ://[[:password][;fingerprint=]@] [:]/// NOTE: This function is available only for SNMPv3. |
| OCT backupRestoreMessage | 1.3.6.1.4.1.2.3.51.2.22.42.3 | OCTET STRING | read-only | Get the status message of the last backup/restore action which was initiated through SNMP. NOTE: This function is only available for SNMPv3. |
| OCT backupRestorePassword | 1.3.6.1.4.1.2.3.51.2.22.42.5 | OCTET STRING | read-write | Password used for the encryption/decryption of the sensitive data in the backup file. It is intended to be write-only. NOTE: This function is only available for SNMPv3. |
| INT backupRestoreStatus | 1.3.6.1.4.1.2.3.51.2.22.42.2 | INTEGER | read-only | Get the status of the last backup/restore action which was initiated through SNMP. NOTE: This function is only available for SNMPv3. |
| OCT backupRestoreURI | 1.3.6.1.4.1.2.3.51.2.22.42.4 | OCTET STRING | read-write | Contains the fully qualified remote location of the file. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the packet file resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The MM currently supports the following protocols: TFTP, FTP, HTTP and HTTPS. The complete format of a fully qualified remote location is: ://@/ An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp/cmd.bkp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the packet file is /tmp/cmd.bkp. Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be::///. Note:When using SFTP, only an RSA fingerprint is supported. An example of a qualified location can be: ://[[:password][;fingerprint=]@] [:]/// NOTE: This function is only available for SNMPv3. |
| OCT bayData | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.6 | OCTET STRING | read-write | A null terminated string that defines the Blade Bay Data (BBD). This data is pushed to the blade's BSMP and SMBIOS structures, where it can used by the blade's OS. Up to 60 characters can be defined plus a Null terminator. |
| INT bayDataBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.3 | INTEGER | read-only | Indicates whether the server blade specified exists or not. |
| INT bayDataBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.2 | INTEGER | read-only | The numeric blade ID. |
| OCT bayDataBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.5 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| INT bayDataBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.4 | INTEGER | read-only | Indicates the power state of the blade specified. |
| INT bayDataBladeStatus | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.7 | INTEGER | read-only | This shows Blade Bay Data (BBD) status. 0 means the blade fully supports BBD; 1 means that the blade's BIOS does not support BBD; 2 means that there is no blade in the bay; 3 means that the blade is being discovered. 255 means that the blade does not support BBD. |
| INT bayDataIndex | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.1 | INTEGER | read-only | Blade bay data (BBD) table index. |
| OCT bistBladesCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.2.49 | OCTET STRING | read-only | The blades that are communicating on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. |
| OCT bistBladesInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.33 | OCTET STRING | read-only | The blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. |
| INT bistBootRomFlashImage | 1.3.6.1.4.1.2.3.51.2.2.5.2.10 | INTEGER | read-only | MM BIST Boot Firmware test result. |
| OCT bistChassisFansFunctional | 1.3.6.1.4.1.2.3.51.2.2.5.2.73 | OCTET STRING | read-only | The chassis fans installed on the chassis that are functional. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number supported. If one is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if it is installed in bay 1, and 2 are supported, the string would look like '10'. |
| OCT bistChassisFansInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.65 | OCTET STRING | read-only | The chassis fans that are installed on the chassis. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number supported. If one is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if it is installed in bay 1, and 2 are supported, the string would look like '10'. |
| INT bistChassisFansMUXAFunctional | 1.3.6.1.4.1.2.3.51.2.2.5.2.121 | INTEGER | read-only | Indicates whether chassis fan MUX A is functional |
| INT bistChassisFansMUXAInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.120 | INTEGER | read-only | Indicates whether chassis fan MUX A is installed |
| INT bistChassisFansMUXBFunctional | 1.3.6.1.4.1.2.3.51.2.2.5.2.123 | INTEGER | read-only | Indicates whether chassis fan MUX B is functional |
| INT bistChassisFansMUXBInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.122 | INTEGER | read-only | Indicates whether chassis fan MUX B is installed |
| INT bistEthernetPort1 | 1.3.6.1.4.1.2.3.51.2.2.5.2.11 | INTEGER | read-only | MM BIST external eth0 ethernet port test result. |
| INT bistExternalI2CDevices | 1.3.6.1.4.1.2.3.51.2.2.5.2.14 | INTEGER | read-only | MM BIST external I2C devices test result. |
| INT bistInternalEthernetSwitch | 1.3.6.1.4.1.2.3.51.2.2.5.2.19 | INTEGER | read-only | MM BIST internal external switch test result. |
| OCT bistLastUpdate | 1.3.6.1.4.1.2.3.51.2.2.5.2.200 | OCTET STRING | read-only | It is the time when the primary MM updated the last BIST results. |
| INT bistLocalI2CBus | 1.3.6.1.4.1.2.3.51.2.2.5.2.7 | INTEGER | read-only | MM BIST Local I2C bus test result. |
| INT bistLogicalNetworkLink | 1.3.6.1.4.1.2.3.51.2.2.5.2.30 | INTEGER | read-only | MM BIST Logical Network Link test result. |
| INT bistOtherMMCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.2.77 | INTEGER | read-only | Indicates whether a redundant MM is communicating. |
| INT bistOtherMMInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.76 | INTEGER | read-only | Indicates whether a redundant MM is installed. |
| INT bistPhysicalNetworkLink | 1.3.6.1.4.1.2.3.51.2.2.5.2.29 | INTEGER | read-only | MM BIST Physical Network Link test result. |
| OCT bistPowerModulesFunctional | 1.3.6.1.4.1.2.3.51.2.2.5.2.89 | OCTET STRING | read-only | The power modules that are functional on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed and functioning in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'. |
| OCT bistPowerModulesInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.81 | OCTET STRING | read-only | The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'. |
| INT bistPrimaryKernel | 1.3.6.1.4.1.2.3.51.2.2.5.2.25 | INTEGER | read-only | MM BIST primary kernel test result. |
| INT bistPrimaryMainAppFlashImage | 1.3.6.1.4.1.2.3.51.2.2.5.2.8 | INTEGER | read-only | MM BIST Primary Main Application Firmware test result. |
| INT bistRearLEDCardCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.2.75 | INTEGER | read-only | Indicates whether a rear LED card is communicating |
| INT bistRearLEDCardInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.74 | INTEGER | read-only | Indicates whether a rear LED card is installed |
| INT bistRtc | 1.3.6.1.4.1.2.3.51.2.2.5.2.5 | INTEGER | read-only | MM BIST Real Time Clock test result. |
| INT bistSecondaryKernel | 1.3.6.1.4.1.2.3.51.2.2.5.2.26 | INTEGER | read-only | MM BIST secondary kernel test result. |
| INT bistSecondaryMainAppFlashImage | 1.3.6.1.4.1.2.3.51.2.2.5.2.9 | INTEGER | read-only | MM BIST Secondary Main Application test result. |
| OCT bistSwitchModulesCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.2.113 | OCTET STRING | read-only | The switch modules that are communicating on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed and functioning in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011'. |
| OCT bistSwitchModulesInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.97 | OCTET STRING | read-only | The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011'. |
| OCT bladeAndExpCardWwnGuidVpd1 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.6 | OCTET STRING | read-only | Blade or expansion card WWN/GUID 1. For consistent results, view as a table and not as individual entries. |
| OCT bladeAndExpCardWwnGuidVpd2 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.7 | OCTET STRING | read-only | Blade or expansion card WWN/GUID 2. For consistent results, view as a table and not as individual entries. |
| OCT bladeAndExpCardWwnGuidVpd3 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.8 | OCTET STRING | read-only | Blade or expansion card WWN/GUID 3. For consistent results, view as a table and not as individual entries. |
| OCT bladeAndExpCardWwnGuidVpd4 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.9 | OCTET STRING | read-only | Blade or expansion card WWN/GUID 4. For consistent results, view as a table and not as individual entries. |
| OCT bladeAndExpCardWwnGuidVpd5 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.10 | OCTET STRING | read-only | Blade or expansion card WWN/GUID 5. For consistent results, view as a table and not as individual entries. |
| OCT bladeAndExpCardWwnGuidVpd6 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.11 | OCTET STRING | read-only | Blade or expansion card WWN/GUID 6. For consistent results, view as a table and not as individual entries. |
| OCT bladeAndExpCardWwnGuidVpd7 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.12 | OCTET STRING | read-only | Blade or expansion card WWN/GUID 7. For consistent results, view as a table and not as individual entries. |
| OCT bladeAndExpCardWwnGuidVpd8 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.13 | OCTET STRING | read-only | Blade or expansion card WWN/GUID 8. For consistent results, view as a table and not as individual entries. |
| OCT bladeAndExpCardWwnGuidVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.2 | OCTET STRING | read-only | Blade or expansion card VPD bay number. For consistent results, view as a table and not as individual entries. |
| OCT bladeAndExpCardWwnGuidVpdBladeBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.4 | OCTET STRING | read-only | For expansion cards, it's the blade bay number of the blade expansion card. For blades, it's the bay number of the blade. For consistent results, view as a table and not as individual entries. |
| bladeAndExpCardWwnGuidVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1 | not-accessible | Blade WWN/GUID entries. For consistent results, view as a table and not as individual entries. | |
| INT bladeAndExpCardWwnGuidVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.1 | INTEGER | read-only | Blade or expansion card index. For consistent results, view as a table and not as individual entries. |
| OCT bladeAndExpCardWwnGuidVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.3 | OCTET STRING | read-only | The name of the blade or expansion card. For consistent results, view as a table and not as individual entries. |
| bladeAndExpCardWwnGuidVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.7 | not-accessible | Table of World Wide Names (WWN), Global Unique IDs (GUID) and Serial Attach SCSI IDs (SAS) of the blade server and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries. | |
| INT bladeAndExpCardWwnGuidVpdType | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.5 | INTEGER | read-only | Blade or expansion card WWN/GUID/SAS Type. For consistent results, view as a table and not as individual entries. |
| bladeBayDataEntry | 1.3.6.1.4.1.2.3.51.2.22.1.13.1 | not-accessible | Blade bay data (BBD) table entry. | |
| bladeBayDataTable | 1.3.6.1.4.1.2.3.51.2.22.1.13 | not-accessible | Table of blade bay data (BBD) information. | |
| OCT bladeBiosVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.6 | OCTET STRING | read-only | The build ID for the blade firmware. |
| OCT bladeBiosVpdDate | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.8 | OCTET STRING | read-only | The date of the blade firmware. |
| bladeBiosVPDEntry | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1 | not-accessible | Blade firmware VPD table entry | |
| INT bladeBiosVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.3 | INTEGER | read-only | Indicates whether the server blade specified exists or not. |
| INT bladeBiosVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.2 | INTEGER | read-only | The numeric blade ID. |
| INT bladeBiosVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.1 | INTEGER | read-only | Blade firmware VPD table index. |
| OCT bladeBiosVpdLevelStatus | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.9 | OCTET STRING | read-only | The level status of the blade bios firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). |
| OCT bladeBiosVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.5 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| INT bladeBiosVpdPowerState | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.4 | INTEGER | read-only | Indicates the power state of the blade specified. |
| OCT bladeBiosVpdRevision | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.7 | OCTET STRING | read-only | The revision of the blade firmware. |
| bladeBiosVPDTable | 1.3.6.1.4.1.2.3.51.2.2.21.5.1 | not-accessible | Table of blade firmware vital product data (VPD) information. | |
| bladeBootCountPowerOnTime | 1.3.6.1.4.1.2.3.51.2.22.1.10 | |||
| bladeBootCountPowerOnTimeEntry | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1 | not-accessible | The number of boots for the blade and the number of seconds the blade has been powered on. | |
| bladeBootCountPowerOnTimeTable | 1.3.6.1.4.1.2.3.51.2.22.1.10.1 | not-accessible | Table per blade of the number of boots for the blade and the number of seconds the blade has been powered on. | |
| bladeCenterSnmpMIB | 1.3.6.1.4.1.2.3.51.2 | |||
| bladeConfiguration | 1.3.6.1.4.1.2.3.51.2.22.1.7 | |||
| bladeConfigurationEntry | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1 | not-accessible | Blade configuration table entry | |
| bladeConfigurationTable | 1.3.6.1.4.1.2.3.51.2.22.1.7.1 | not-accessible | Table of blade configuration information. Contains boot mode and auto power on/off settings for each blade. | |
| INT bladeConnectionType | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.10 | INTEGER | read-only | Connection type of the expansion card number one. |
| INT bladeConnectionType2 | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.22 | INTEGER | read-only | Connection type of the expansion card number 2. |
| INT bladeConnectionType3 | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.23 | INTEGER | read-only | Connection type of the expansion card number 3. |
| INT bladeConnectionType4 | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.24 | INTEGER | read-only | Connection type of the expansion card number 4. |
| INT bladeConnectionType5 | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.25 | INTEGER | read-only | Connection type of the expansion card number 5. |
| OCT bladeDaughterCard1MACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.10 | OCTET STRING | read-only | Blade expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard1MACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.11 | OCTET STRING | read-only | Blade expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard1MACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.12 | OCTET STRING | read-only | Blade expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard1MACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.13 | OCTET STRING | read-only | Blade expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard1MACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.14 | OCTET STRING | read-only | Blade expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard1MACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.15 | OCTET STRING | read-only | Blade expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard1MACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.16 | OCTET STRING | read-only | Blade expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard1MACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.17 | OCTET STRING | read-only | Blade expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard2MACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.18 | OCTET STRING | read-only | Blade expansion card (daughter card) 2 MAC address 1. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard2MACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.19 | OCTET STRING | read-only | Blade expansion card (daughter card) 2 MAC address 2. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard2MACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.20 | OCTET STRING | read-only | Blade expansion card (daughter card) 2 MAC address 3. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard2MACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.21 | OCTET STRING | read-only | Blade expansion card (daughter card) 2 MAC address 4. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard2MACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.22 | OCTET STRING | read-only | Blade expansion card (daughter card) 2 MAC address 5. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard2MACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.23 | OCTET STRING | read-only | Blade expansion card (daughter card) 2 MAC address 6. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard2MACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.24 | OCTET STRING | read-only | Blade expansion card (daughter card) 2 MAC address 7. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard2MACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.25 | OCTET STRING | read-only | Blade expansion card (daughter card) 2 MAC address 8. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard3MACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.26 | OCTET STRING | read-only | Blade expansion card (daughter card) 3 MAC address 1. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard3MACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.27 | OCTET STRING | read-only | Blade expansion card (daughter card) 3 MAC address 2. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard3MACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.28 | OCTET STRING | read-only | Blade expansion card (daughter card) 3 MAC address 3. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard3MACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.29 | OCTET STRING | read-only | Blade expansion card (daughter card) 3 MAC address 4. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard3MACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.30 | OCTET STRING | read-only | Blade expansion card (daughter card) 3 MAC address 5. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard3MACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.31 | OCTET STRING | read-only | Blade expansion card (daughter card) 3 MAC address 6. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard3MACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.32 | OCTET STRING | read-only | Blade expansion card (daughter card) 3 MAC address 7. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard3MACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.33 | OCTET STRING | read-only | Blade expansion card (daughter card) 3 MAC address 8. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard4MACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.34 | OCTET STRING | read-only | Blade expansion card (daughter card) 4 MAC address 1. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard4MACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.35 | OCTET STRING | read-only | Blade expansion card (daughter card) 4 MAC address 2. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard4MACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.36 | OCTET STRING | read-only | Blade expansion card (daughter card) 4 MAC address 3. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard4MACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.37 | OCTET STRING | read-only | Blade expansion card (daughter card) 4 MAC address 4. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard4MACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.38 | OCTET STRING | read-only | Blade expansion card (daughter card) 4 MAC address 5. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard4MACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.39 | OCTET STRING | read-only | Blade expansion card (daughter card) 4 MAC address 6. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard4MACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.40 | OCTET STRING | read-only | Blade expansion card (daughter card) 4 MAC address 7. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard4MACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.41 | OCTET STRING | read-only | Blade expansion card (daughter card) 4 MAC address 8. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard5MACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.42 | OCTET STRING | read-only | Blade expansion card (daughter card) 5 MAC address 1. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard5MACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.43 | OCTET STRING | read-only | Blade expansion card (daughter card) 5 MAC address 2. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard5MACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.44 | OCTET STRING | read-only | Blade expansion card (daughter card) 5 MAC address 3. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard5MACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.45 | OCTET STRING | read-only | Blade expansion card (daughter card) 5 MAC address 4. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard5MACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.46 | OCTET STRING | read-only | Blade expansion card (daughter card) 5 MAC address 5. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard5MACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.47 | OCTET STRING | read-only | Blade expansion card (daughter card) 5 MAC address 6. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard5MACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.48 | OCTET STRING | read-only | Blade expansion card (daughter card) 5 MAC address 7. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterCard5MACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.49 | OCTET STRING | read-only | Blade expansion card (daughter card) 5 MAC address 8. For consistent results, view as a table and not as individual entries. |
| INT bladeDaughterVpdCardType | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.20 | INTEGER | read-only | Blade expansion card (daughter card) VPD type. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.33 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.22 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD FRU number. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.29 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD FRU Serial. For consistent results, view as a table and not as individual entries. |
| INT bladeDaughterVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.23 | INTEGER | read-only | Blade expansion card (daughter card) VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. |
| OCT bladeDaughterVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.34 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. |
| OCT bladeDaughterVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.25 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD Machine type. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.21 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD manufacturing ID. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.30 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.27 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD Manufacture date. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.28 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD Part number. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.31 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD product ID. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.24 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD Serial number. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.32 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD subsystem manufacturing ID. For consistent results, view as a table and not as individual entries. |
| OCT bladeDaughterVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.26 | OCTET STRING | read-only | Blade expansion card (daughter card) VPD UUID. For consistent results, view as a table and not as individual entries. |
| bladeDetails | 1.3.6.1.4.1.2.3.51.2.2.10.4.1 | |||
| INT bladeDetailsDynamicPowerFavorPerformanceOverPower | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.8 | INTEGER | read-write | When enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and memory utilization implies it would help and the system allows it. Dynamic Power Performance Over Power can be active on the blade only after Dynamic Power Saver is enabled. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power favor performance over power may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. |
| INT bladeDetailsDynamicPowerSaver | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.7 | INTEGER | read-write | When enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the blade to be controlled based on how busy the CPU is. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power saver may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsPowerSaverMode if its not already disabled. |
| OCT bladeDetailsEffectiveClockRate | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4 | OCTET STRING | read-only | Blade Module Details Table Effective CPU Clock Rate applies to DPM blades only. It displays processor's effective clock rate based on sample interval. Note that some blades do not effective clock rate. In this case, 'notApplicable' will be displayed. NOTE: The effective clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The effective clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4. |
| bladeDetailsEntry | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1 | not-accessible | Blade Module Details entry. | |
| INT bladeDetailsId | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.2 | INTEGER | read-only | Blade Module Details Table Blade Id. |
| INT bladeDetailsIndex | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.1 | INTEGER | read-only | Blade Module Details Table Index. |
| OCT bladeDetailsMaximumClockRate | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5 | OCTET STRING | read-only | Blade Module Details Table Maximum CPU Clock Rate applies to DPM blades only. It displays processor's maximum clock rate based on sample interval. Note that some blades do not maximum clock rate. In this case, 'notApplicable' will be displayed. NOTE: The maximum clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The maximum clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4. |
| INT bladeDetailsMaxPowerConfig | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.3 | INTEGER | read-write | Blade Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the blade. This function is also known as power capping. Blade must be powered on to set this value. If the value of maximum power config is zero, it means the blade doesn't support the power capping feature |
| OCT bladeDetailsPcapGuaranteedMin | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.11 | OCTET STRING | read-only | Blade Module Details Table power capping Guaranteed Minimum value in watts. The blade must support the advanced power management feature. If the value of Pcap Guaranteed Min is 'notApplicable', it means the blade doesn't support the power capping feature. If the value of Pcap GuaranteedMin is 'notAvailable', it means the data could not be obtained. |
| OCT bladeDetailsPcapMax | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.12 | OCTET STRING | read-only | Blade Module Details Table power capping Maximum value in watts. The blade must support the advanced power management feature. If the value is ' Watts, Watts', which means, - if bladeDetailsDynamicPowerSaver is enabled, it is - otherwise it is If the value of Pcap Max is 'notApplicable', it means the blade doesn't support the power capping feature. If the value of Pcap Min is 'notAvailable', it means the data could not be obtained. |
| OCT bladeDetailsPcapMin | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.10 | OCTET STRING | read-only | Blade Module Details Table power capping Minimum value in watts. The blade must support the advanced power management feature. If the value of Pcap Min is 'notApplicable', it means the blade doesn't support the power capping feature. If the value of Pcap Min is 'notAvailable', it means the data could not be obtained. |
| INT bladeDetailsPowerControl | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.9 | INTEGER | read-write | This object is used to get or set the power control setting on a blade. If dynamic power mgmt is not supported on a blade, notApplicable(255) will be returned. This will set the power control setting on all slots of the multiwide blade. The same can be used if the blade is single wide. |
| INT bladeDetailsPowerSaverMode | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.6 | INTEGER | read-write | When enabled, the static low power saver mode allows the blade to selectively alter its operating voltage and frequency to reduce power consumption. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the static low power saver mode, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the static low power saver mode may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsDynamicPowerSaver if its not already disabled. |
| bladeDetailsTable | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1 | not-accessible | Table of Blade Module Details. | |
| INT bladeDHCPv6ConfigEnabled | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.5 | INTEGER | read-write | Enables/Disables DHCPv6 address configuration support on the blade. |
| OCT bladeDiagsVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.6 | OCTET STRING | read-only | The build ID for the blade firmware. |
| OCT bladeDiagsVpdDate | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.8 | OCTET STRING | read-only | The date of the blade firmware. |
| bladeDiagsVPDEntry | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1 | not-accessible | Blade firmware VPD table entry | |
| INT bladeDiagsVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.3 | INTEGER | read-only | Indicates whether the server blade specified exists or not. |
| INT bladeDiagsVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.2 | INTEGER | read-only | The numeric blade ID. |
| INT bladeDiagsVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.1 | INTEGER | read-only | Blade firmware VPD table index. |
| OCT bladeDiagsVpdLevelStatus | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.9 | OCTET STRING | read-only | The level status of the blade diagnostics firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). |
| OCT bladeDiagsVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.5 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| INT bladeDiagsVpdPowerState | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.4 | INTEGER | read-only | Indicates the power state of the blade specified. |
| OCT bladeDiagsVpdRevision | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.7 | OCTET STRING | read-only | The revision of the blade firmware. |
| bladeDiagsVPDTable | 1.3.6.1.4.1.2.3.51.2.2.21.5.2 | not-accessible | Table of blade firmware vital product data (VPD) information. | |
| INT bladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.3 | INTEGER | read-only | Indicates whether the server blade specified exists or not. |
| OCT bladeExpCardVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.2 | OCTET STRING | read-only | Blade expansion card VPD Bay number. For consistent results, view as a table and not as individual entries. |
| OCT bladeExpCardVpdBladeBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.19 | OCTET STRING | read-only | Blade bay number of the blade expansion card. For consistent results, view as a table and not as individual entries. |
| INT bladeExpCardVpdCardTypeInfo | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.21 | INTEGER | read-only | Blade expansion card (daughter card) VPD type code that describes the expansion card. For consistent results, view as a table and not as individual entries. NOTE: The CFFe expansion card is also referred to as a CFFh expansion card. |
| OCT bladeExpCardVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.16 | OCTET STRING | read-only | Blade expansion card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. |
| bladeExpCardVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1 | not-accessible | Blade expansion card VPD entry. For consistent results, view as a table and not as individual entries. | |
| OCT bladeExpCardVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.4 | OCTET STRING | read-only | Blade expansion card VPD FRU number. For consistent results, view as a table and not as individual entries. |
| OCT bladeExpCardVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.11 | OCTET STRING | read-only | Blade expansion card VPD FRU serial number. For consistent results, view as a table and not as individual entries. |
| INT bladeExpCardVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.5 | INTEGER | read-only | Blade expansion card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. |
| OCT bladeExpCardVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.23 | OCTET STRING | read-only | Blade expansion card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. |
| INT bladeExpCardVpdHighSpeed | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.22 | INTEGER | read-only | Blade expansion card (daughter card) VPD high speed that indicates whether the expansion card is high speed or not. For consistent results, view as a table and not as individual entries. |
| INT bladeExpCardVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.1 | INTEGER | read-only | Blade expansion card VPD index. For consistent results, view as a table and not as individual entries. |
| OCT bladeExpCardVpdMachineModel | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.12 | OCTET STRING | read-only | Blade expansion card VPD machine model. For consistent results, view as a table and not as individual entries. |
| OCT bladeExpCardVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.7 | OCTET STRING | read-only | Blade expansion card VPD machine type. For consistent results, view as a table and not as individual entries. |
| OCT bladeExpCardVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.3 | OCTET STRING | read-only | Blade expansion card VPD manufacturing ID. For consistent results, view as a table and not as individual entries. |
| OCT bladeExpCardVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.13 | OCTET STRING | read-only | Blade expansion card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries. |
| OCT bladeExpCardVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.9 | OCTET STRING | read-only | Blade expansion card VPD Manufacture Date. For consistent results, view as a table and not as individual entries. |
| OCT bladeExpCardVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.10 | OCTET STRING | read-only | Blade expansion card VPD Part number. For consistent results, view as a table and not as individual entries. |
| OCT bladeExpCardVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.14 | OCTET STRING | read-only | Blade expansion card VPD Product ID. For consistent results, view as a table and not as individual entries. |
| OCT bladeExpCardVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.6 | OCTET STRING | read-only | Blade expansion card VPD serial number. For consistent results, view as a table and not as individual entries. |
| OCT bladeExpCardVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.15 | OCTET STRING | read-only | Blade expansion card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. |
| bladeExpCardVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.5 | not-accessible | Table of VPD information for the blade expansion card components. For consistent results, view as a table and not as individual entries. | |
| OCT bladeExpCardVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.8 | OCTET STRING | read-only | Blade expansion card VPD UUID. For consistent results, view as a table and not as individual entries. |
| bladeFirmwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.5 | |||
| bladeHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.4 | |||
| OCT bladeHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.2 | OCTET STRING | read-only | Blade hardware VPD Bay number. For consistent results, view as a table and not as individual entries. |
| OCT bladeHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.16 | OCTET STRING | read-only | Blade hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. |
| bladeHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1 | not-accessible | Blade hardware VPD entry. For consistent results, view as a table and not as individual entries. | |
| OCT bladeHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.4 | OCTET STRING | read-only | Blade hardware VPD FRU number. For consistent results, view as a table and not as individual entries. |
| OCT bladeHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.11 | OCTET STRING | read-only | Blade hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. |
| INT bladeHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.5 | INTEGER | read-only | Blade hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. |
| OCT bladeHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.17 | OCTET STRING | read-only | Blade hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. |
| INT bladeHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.1 | INTEGER | read-only | Blade hardware VPD index. For consistent results, view as a table and not as individual entries. |
| OCT bladeHardwareVpdMachineModel | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.12 | OCTET STRING | read-only | Blade hardware VPD machine model. For consistent results, view as a table and not as individual entries. |
| OCT bladeHardwareVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.7 | OCTET STRING | read-only | Blade hardware VPD machine type. For consistent results, view as a table and not as individual entries. |
| OCT bladeHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.3 | OCTET STRING | read-only | Blade hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. |
| OCT bladeHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.13 | OCTET STRING | read-only | Blade hardware VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries. |
| OCT bladeHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.9 | OCTET STRING | read-only | Blade hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries. |
| OCT bladeHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.10 | OCTET STRING | read-only | Blade hardware VPD Part number. For consistent results, view as a table and not as individual entries. |
| OCT bladeHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.14 | OCTET STRING | read-only | Blade hardware VPD product ID. For consistent results, view as a table and not as individual entries. |
| OCT bladeHardwareVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.6 | OCTET STRING | read-only | Blade hardware VPD serial number. For consistent results, view as a table and not as individual entries. |
| OCT bladeHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.15 | OCTET STRING | read-only | Blade hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. |
| bladeHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.1 | not-accessible | Table of VPD information for the blade hardware components. For consistent results, view as a table and not as individual entries. | |
| OCT bladeHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.8 | OCTET STRING | read-only | Blade hardware VPD UUID. For consistent results, view as a table and not as individual entries. |
| INT bladeHealthState | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.5 | INTEGER | read-only | The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The MM is currently in the process of discovering this blade. Communications Error: The MM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. |
| INT bladeHealthSummaryBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.2 | INTEGER | read-only | The numeric blade ID. |
| OCT bladeHealthSummaryDateTime | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.5 | OCTET STRING | read-only | System health summary date time. |
| OCT bladeHealthSummaryDescription | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.4 | OCTET STRING | read-only | System health summary description. |
| bladeHealthSummaryEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1 | not-accessible | Blade health summary entry | |
| OCT bladeHealthSummaryEventID | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.6 | OCTET STRING | read-only | System health summary event ID. |
| INT bladeHealthSummaryIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.1 | INTEGER | read-only | Blade health summary index. |
| OCT bladeHealthSummarySeverity | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.3 | OCTET STRING | read-only | System health summary severity. |
| bladeHealthSummaryTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.2 | not-accessible | Table of blade health summary information. Contains information about the overall blade health status. | |
| INT bladeHighSpeedConnectionType | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.41 | INTEGER | read-only | Connection type of the high speed expansion card number 1. |
| OCT bladeHSDaughterCard1MACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.100 | OCTET STRING | read-only | Blade high speed expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries. |
| OCT bladeHSDaughterCard1MACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.101 | OCTET STRING | read-only | Blade high speed expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries. |
| OCT bladeHSDaughterCard1MACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.102 | OCTET STRING | read-only | Blade high speed expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries. |
| OCT bladeHSDaughterCard1MACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.103 | OCTET STRING | read-only | Blade high speed expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries. |
| OCT bladeHSDaughterCard1MACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.104 | OCTET STRING | read-only | Blade high speed expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries. |
| OCT bladeHSDaughterCard1MACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.105 | OCTET STRING | read-only | Blade high speed expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries. |
| OCT bladeHSDaughterCard1MACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.106 | OCTET STRING | read-only | Blade high speed expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries. |
| OCT bladeHSDaughterCard1MACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.107 | OCTET STRING | read-only | Blade high speed expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries. |
| INT bladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.2 | INTEGER | read-only | The numeric blade ID. |
| INT bladeInventoryReady | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.52 | INTEGER | read-only | When a blade management controller or the MM is reset, the blade inventory data is refreshed in the MM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the MM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication for each blade regarding the status of this information. Notes: For blades that are experiencing a 'communication failure' or 'initialization failure' condition, this object will continue to indicate notReady until the condition is resolved. Therefore, any application that polls this object should also incorporate a timeout period. |
| OCT bladeIOCompatibility | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.51 | OCTET STRING | read-only | I/O compatibility status for the blade. The possible values and their meanings are as follows: unknown: This indicates a communication error for the blade. ok: This is the normal (good) case where the blade and the corresponding I/O modules it is internally wired to have no compatibility issues. noIOMs: This means there are no I/O modules in any of the corresponding I/O module bays this blade is internally wired to. attention: This indicates that one or more of the corresponding I/O modules are in communication error. mismatch: This indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on the blade |
| INT bladeIPv4ConfigDHCPEnable | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.10 | INTEGER | read-write | IP config method on the blade network interface to modify mode to static IP, DHCP and 'try DHCP then try static'. If this network interface doesn't support DHCP, show 'notApplicable(255)'. |
| bladeIPv4ConfigEntry | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1 | not-accessible | Blade configuration table entry | |
| IP bladeIPv4ConfigGatewayAddr | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.8 | IpAddress | read-write | Show or modify current IP gateway of the blade network interface. Note that only if the bladeIPv4ConfigPhysicalLinkStatus is 'up(1)' and the bladeIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to blade System Management Processor. |
| INT bladeIPv4ConfigIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.1 | INTEGER | read-only | The blade's slot number. |
| IP bladeIPv4ConfigIPAddr | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.6 | IpAddress | read-write | Show/modify current IP address of the blade network interface. Note that only if the bladeIPv4ConfigPhysicalLinkStatus is 'up(1)' and the bladeIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to blade System Management Processor. |
| OCT bladeIPv4ConfigMACAddr | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.11 | OCTET STRING | read-only | Show the blade network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable'. |
| INT bladeIPv4ConfigPhysicalLinkState | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.5 | INTEGER | read-write | Configuration object for requesting the physical port to be either, down(0), up(1) or loopback(2). To get the current status of a physical port, use the object, bladeIPv4ConfigPhysicalLinkStatus. If this network interface doesn't support up/down/loopback, show 'notApplicable(255)'. |
| INT bladeIPv4ConfigPhysicalLinkStatus | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.4 | INTEGER | read-only | Indicates whether this network interface port is up or down. If this network interface doesn't support up/down, show 'notApplicable(255)'. |
| INT bladeIPv4ConfigPortIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.2 | INTEGER | read-only | The physical port number of the given entry. |
| OCT bladeIPv4ConfigPortLabel | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.3 | OCTET STRING | read-only | Show string label that identifies the interface. |
| IP bladeIPv4ConfigSubnetMask | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.7 | IpAddress | read-write | Show or modifie current subnet mask of the blade network interface. Note that only if the bladeIPv4ConfigPhysicalLinkStatus is 'up(1)' and the bladeIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to blade System Management Processor. |
| bladeIPv4ConfigTable | 1.3.6.1.4.1.2.3.51.2.22.1.12.5 | not-accessible | Table of all blades' network interfaces. | |
| INT bladeIPv4ConfigVlanId | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.9 | INTEGER | read-write | This is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095. |
| ADR bladeIPv6Address | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.5 | InetAddressIPv6 | read-write | The assigned IPv6 address. Note: 'write' is for static ipv6 only. |
| ADR bladeIPv6AddressDefaultRoute | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.7 | InetAddressIPv6 | read-write | The default route used for the given address. Note: 'write' is for static ipv6 only. |
| bladeIPv6AddressEntry | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1 | not-accessible | The assigned IPv6 address for a given blade. NOTE: This MIB object is not applicable to blades that do not support IPv6. | |
| INT bladeIPv6AddressEntryIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.3 | INTEGER | read-only | The blade's address entry index. |
| INT bladeIPv6AddressIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.1 | INTEGER | read-only | The blade's slot number. |
| INT bladeIPv6AddressPortIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.2 | INTEGER | read-only | The blade's physical port number for the given entry. |
| INT bladeIPv6AddressPrefixLen | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.6 | INTEGER | read-write | The prefix length for the given address. Note: 'write' is for static ipv6 only. |
| bladeIPv6AddressTable | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2 | not-accessible | A table of assigned IPv6 addresses for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6. | |
| INT bladeIPv6AddressType | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.4 | INTEGER | read-only | The address type. |
| bladeIPv6Config | 1.3.6.1.4.1.2.3.51.2.22.1.12.10 | |||
| INT bladeIPv6ConfigEnabled | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.3 | INTEGER | read-write | Enables/Disables IPv6 support on the blade. |
| bladeIPv6ConfigEntry | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1 | not-accessible | IPv6 configuration options for a blade. NOTE: This MIB object is not applicable to blades that do not support IPv6. | |
| INT bladeIPv6ConfigIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.1 | INTEGER | read-only | The blade's slot number |
| INT bladeIPv6ConfigPortIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.2 | INTEGER | read-only | The physical port number of the given entry |
| INT bladeIPv6ConfigStatelessEnabled | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.6 | INTEGER | read-write | Enables/Disables IPv6 stateless auto-configuration support on the blade. |
| INT bladeIPv6ConfigStatic | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.4 | INTEGER | read-write | Enables/Disables IPv6 static configuration support on the blade. |
| bladeIPv6ConfigTable | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1 | not-accessible | A table of IPv6 configuration options for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6. | |
| bladeLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.2 | |||
| bladeLEDsDetailsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1 | not-accessible | Blade LEDs Details entry | |
| bladeLEDsDetailsTable | 1.3.6.1.4.1.2.3.51.2.2.8.2.2 | not-accessible | Table of blade LEDs detailed information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more. | |
| bladeLEDsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1 | not-accessible | Blade system status entry | |
| bladeLEDsTable | 1.3.6.1.4.1.2.3.51.2.2.8.2.1 | not-accessible | Table of blade status information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more. | |
| OCT bladeMACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.2 | OCTET STRING | read-only | Blade MAC address 1. For consistent results, view as a table and not as individual entries. |
| OCT bladeMACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.3 | OCTET STRING | read-only | Blade MAC address 2. For consistent results, view as a table and not as individual entries. |
| OCT bladeMACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.4 | OCTET STRING | read-only | Blade MAC address 3. For consistent results, view as a table and not as individual entries. |
| OCT bladeMACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.5 | OCTET STRING | read-only | Blade MAC address 4. For consistent results, view as a table and not as individual entries. |
| OCT bladeMACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.6 | OCTET STRING | read-only | Blade MAC address 5. For consistent results, view as a table and not as individual entries. |
| OCT bladeMACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.7 | OCTET STRING | read-only | Blade MAC address 6. For consistent results, view as a table and not as individual entries. |
| OCT bladeMACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.8 | OCTET STRING | read-only | Blade MAC address 7. For consistent results, view as a table and not as individual entries. |
| OCT bladeMACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.9 | OCTET STRING | read-only | Blade MAC address 8. For consistent results, view as a table and not as individual entries. |
| bladeMACAddressVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1 | not-accessible | Blade MAC address entry. For consistent results, view as a table and not as individual entries. | |
| INT bladeMACAddressVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.1 | INTEGER | read-only | Blade index. For consistent results, view as a table and not as individual entries. |
| bladeMACAddressVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.2 | not-accessible | Table of MAC addresses of the blade and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries. | |
| OCT bladeManagementCardVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.2 | OCTET STRING | read-only | Blade management card VPD Bay number. For consistent results, view as a table and not as individual entries. |
| OCT bladeManagementCardVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.16 | OCTET STRING | read-only | Blade management card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. |
| bladeManagementCardVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1 | not-accessible | Blade management card VPD entry. For consistent results, view as a table and not as individual entries. | |
| OCT bladeManagementCardVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.4 | OCTET STRING | read-only | Blade management card VPD FRU number. For consistent results, view as a table and not as individual entries. |
| OCT bladeManagementCardVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.11 | OCTET STRING | read-only | Blade management card VPD FRU serial number. For consistent results, view as a table and not as individual entries. |
| INT bladeManagementCardVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.5 | INTEGER | read-only | Blade management card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. |
| OCT bladeManagementCardVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.17 | OCTET STRING | read-only | Blade management card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. |
| INT bladeManagementCardVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.1 | INTEGER | read-only | Blade management card VPD index. For consistent results, view as a table and not as individual entries. |
| OCT bladeManagementCardVpdMachineModel | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.12 | OCTET STRING | read-only | Blade management card VPD machine model. For consistent results, view as a table and not as individual entries. |
| OCT bladeManagementCardVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.7 | OCTET STRING | read-only | Blade management card VPD machine type. For consistent results, view as a table and not as individual entries. |
| OCT bladeManagementCardVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.3 | OCTET STRING | read-only | Blade management card VPD manufacturing ID. For consistent results, view as a table and not as individual entries. |
| OCT bladeManagementCardVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.13 | OCTET STRING | read-only | Blade management card VPD manufacturer ID. For consistent results, view as a table and not as individual entries. |
| OCT bladeManagementCardVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.9 | OCTET STRING | read-only | Blade management card VPD Manufacture Date. For consistent results, view as a table and not as individual entries. |
| OCT bladeManagementCardVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.10 | OCTET STRING | read-only | Blade management card VPD Part number. For consistent results, view as a table and not as individual entries. |
| OCT bladeManagementCardVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.14 | OCTET STRING | read-only | Blade management card VPD Product ID. For consistent results, view as a table and not as individual entries. |
| OCT bladeManagementCardVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.6 | OCTET STRING | read-only | Blade management card VPD serial number. For consistent results, view as a table and not as individual entries. |
| OCT bladeManagementCardVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.15 | OCTET STRING | read-only | Blade management card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. |
| bladeManagementCardVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.8 | not-accessible | Table of VPD information for the blade management card component. For consistent results, view as a table and not as individual entries. | |
| OCT bladeManagementCardVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.8 | OCTET STRING | read-only | Blade management card VPD UUID. For consistent results, view as a table and not as individual entries. |
| bladeMonitors | 1.3.6.1.4.1.2.3.51.2.22.1.5 | |||
| OCT bladeName | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.6 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| bladeNetworkConfiguration | 1.3.6.1.4.1.2.3.51.2.22.1.12 | |||
| OCT bladePlus12Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.8 | OCTET STRING | read-only | +12 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus12VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.10 | OCTET STRING | read-only | Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus12VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.11 | OCTET STRING | read-only | Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus1pt25Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.12 | OCTET STRING | read-only | +1.25 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus1pt25VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.18 | OCTET STRING | read-only | Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus1pt25VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.19 | OCTET STRING | read-only | Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus1pt5Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.11 | OCTET STRING | read-only | +1.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus1pt5VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.16 | OCTET STRING | read-only | Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus1pt5VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.17 | OCTET STRING | read-only | Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus2pt5Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.10 | OCTET STRING | read-only | +2.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus2pt5VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.14 | OCTET STRING | read-only | Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus2pt5VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.15 | OCTET STRING | read-only | Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus3pt3Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.7 | OCTET STRING | read-only | +3.3 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus3pt3VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.8 | OCTET STRING | read-only | Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus3pt3VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.9 | OCTET STRING | read-only | Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus5Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.6 | OCTET STRING | read-only | +5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus5VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.6 | OCTET STRING | read-only | Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladePlus5VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.7 | OCTET STRING | read-only | Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| bladePolicy | 1.3.6.1.4.1.2.3.51.2.22.1.4.2 | |||
| bladePolicyControl | 1.3.6.1.4.1.2.3.51.2.22.1.4 | |||
| bladePolicyControlEntry | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1 | not-accessible | Power policy control entry | |
| bladePolicyControlTable | 1.3.6.1.4.1.2.3.51.2.22.1.4.1 | not-accessible | Table of blade power policy control information. Contains power on/off enablement status for each blade. | |
| INT bladePolicyLocalPowerControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.1 | INTEGER | read-write | Blade local power control enablement status policy. |
| INT bladePolicyWakeOnLanControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.4 | INTEGER | read-write | Blade Wake On LAN enablement status policy. The notApplicable(255) enumeration is not valid for SET operations. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT bladePowerEnableSMSBootMenu | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.15 | INTEGER | read-write | Enables/disables a blade restart to the SMS boot menu. Setting this object to 'enable(1)' will cause a reboot of the node to the SMS menu. This option is not supported by all blades, and at the time of this MIB definition was only supported on POWER blades. |
| bladePowerManagementPolicy | 1.3.6.1.4.1.2.3.51.2.22.1.7.2 | |||
| bladePowerRestart | 1.3.6.1.4.1.2.3.51.2.22.1.6 | |||
| bladePowerRestartEntry | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1 | not-accessible | Blade power restart table entry | |
| bladePowerRestartTable | 1.3.6.1.4.1.2.3.51.2.22.1.6.1 | not-accessible | Table of blade remote power control information. Contains power on/off enablement status for each blade. | |
| INT bladePowerServiceResetBladeId | 1.3.6.1.4.1.2.3.51.2.23.10.1.1.2 | INTEGER | read-only | The numeric blade slot number. |
| INT bladePowerServiceResetCmd | 1.3.6.1.4.1.2.3.51.2.23.10.1.1.4 | INTEGER | read-write | NOTE: Do not perform this service reset operation on a node that is currently in a maintenance mode state. See bladeHealthState in bladeSystemStatusTable for maintMode(12) value. To reset the auxiliary power on a blade component, set this object to resetVirtualReseatOperation(1). This will toggle the auxiliary power to the blade and simulate a physical removal and insertion. During the operation, auxiliary power is removed from the component and is then restored. For nodes, the power state will remain off and the user will need to manually power on the node. To perform a hard restart on the blade component, set this object to resetHardRestartOperation(2). This will toggle the reset line to the service processor causing it to re-initialize. The service processor on the component is directly reset, but the power state of the component will not be affected by this operation. This object is intended to be write-only. The component will experience a temporary loss of communication and the power state will change. Prior to executing this action, perform any operations needed to protect user data. Reading this object will always return the value of noOperation(0). |
| bladePowerServiceResetEntry | 1.3.6.1.4.1.2.3.51.2.23.10.1.1 | not-accessible | Blade power service reset entry | |
| INT bladePowerServiceResetIndex | 1.3.6.1.4.1.2.3.51.2.23.10.1.1.1 | INTEGER | read-only | Blade power service reset index. |
| INT bladePowerServiceResetStatus | 1.3.6.1.4.1.2.3.51.2.23.10.1.1.3 | INTEGER | read-only | Status of the aux power. A value of auxPowerOff(0) indicates that the blade aux power is off. A value of auxPowerOn(1) indicates that the blade aux power is on. |
| bladePowerServiceResetTable | 1.3.6.1.4.1.2.3.51.2.23.10.1 | not-accessible | A table providing aux power status and the ability to perform a virtual reseat or hard restart of a blade. | |
| INT bladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.4 | INTEGER | read-only | Indicates the power state of the blade specified. |
| bladePowerTrending | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3 | |||
| INT bladePowerTrendingBladeId | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.2 | INTEGER | read-write | Blade Module Power Trending Blade Id. NOTE: The Blade Id should be configured before displaying the bladePowerTrendingTable. |
| INT bladePowerTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1 | INTEGER | read-write | Specify time period for blade module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Blade Module. Since the power trending data is constantly being computed and saved in the management application database, some queries of the bladePowerTrendingSampleTable may not provide information for a very short window of time. If the table returns empty, please wait a short period and retry the query. |
| OCT bladePowerTrendingSampleAve | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.6 | OCTET STRING | read-only | Blade Module Power Trending Sample Table Average Power. |
| bladePowerTrendingSampleEntry | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1 | not-accessible | Blade Module Power Trending Sample entry. | |
| INT bladePowerTrendingSampleId | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.2 | INTEGER | read-only | Blade Module Power Trending Sample Table Blade Id. If the blade is defined using a topology location by using the scalar bladePowerTrendingTopologyPath, a zero will be displayed in the bladePowerTrendingSampleId. |
| INT bladePowerTrendingSampleIndex | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.1 | INTEGER | read-only | Blade Module Power Trending Sample Table Index. |
| OCT bladePowerTrendingSampleMax | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.4 | OCTET STRING | read-only | Blade Module Power Trending Sample Table Maximum Power. |
| OCT bladePowerTrendingSampleMin | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.5 | OCTET STRING | read-only | Blade Module Power Trending Sample Table Minimum Power. |
| bladePowerTrendingSampleTable | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10 | not-accessible | Table of Blade Module Power Trending Information. Since the power trending data is constantly being computed and saved in the management application database, some queries of this table may not provide information for a very short window of time. If the table data returns empty,please wait a short period and retry the query. | |
| OCT bladePowerTrendingSampleTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.3 | OCTET STRING | read-only | Blade Module Power Trending Sample Table Timestamp. |
| OCT bladePowerTrendingSampleTopologyId | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.7 | OCTET STRING | read-only | Blade module topology path. This field will have a topology location when a blade is a storage blade or a blade defined with a sub chassis. If the blade is defined with a primary slot location by using the scalar bladePowerTrendingBladeId, 'not applicable' will be displayed in the bladePowerTrendingSampleTopologyId. |
| OCT bladePowerTrendingTopologyPath | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.3 | OCTET STRING | read-write | The topology Path is a location identifier for a blade. The chassis and each installed blade is represented by a hardware topology tree, where each node in the tree represents a blade. The path to a particular blade consists of one or more , pairs, where each successive pair is a child of the previous parent pair. This topology path is used to identify blades such as blade storage devices. Some examples. A storage blade with a controller card plugged into slot 1 topology location would be represented as : 010103010301--> Storage Controller card #1 of Sub-Chassis #1 A storage blade with a controller card plugged into slot 2 topology location would be represented as : 010103010302--> Storage Controller card #2 of Sub-Chassis #1 |
| INT bladeRemotePowerEnable | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.7 | INTEGER | read-only | Remote power state for the blade. |
| INT bladeRemoteWakeOnLanEnable | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.13 | INTEGER | read-only | Remote wake on LAN state for the blade. |
| OCT bladeSensor10Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.24 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor10VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.41 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor10VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.42 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor11Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.25 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor11VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.43 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor11VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.44 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor12Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.26 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor12VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.45 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor12VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.46 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor13Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.27 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor13VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.47 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor13VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.48 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor14Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.28 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor14VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.49 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor14VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.50 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor15Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.29 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor15VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.51 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor15VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.52 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor16Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.30 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor16VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.53 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor16VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.54 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor17Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.31 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor17VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.55 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor17VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.56 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor18Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.32 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor18VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.57 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor18VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.58 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor19Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.33 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor19VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.59 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor19VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.60 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor1Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.12 | OCTET STRING | read-only | Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor1Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.15 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor1VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.23 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor1VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.24 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor20Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.34 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor20VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.61 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor20VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.62 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor21Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.35 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor21VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.63 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor21VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.64 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor22Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.36 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor22VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.65 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor22VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.66 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor23Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.37 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor23VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.67 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor23VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.68 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor24Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.38 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor24VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.69 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor24VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.70 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor25Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.39 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor25VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.71 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor25VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.72 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor26Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.40 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor26VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.73 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor26VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.74 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor27Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.41 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor27VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.75 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor27VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.76 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor28Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.42 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor28VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.77 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor28VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.78 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor29Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.43 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor29VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.79 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor29VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.80 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor2Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.13 | OCTET STRING | read-only | Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor2Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.16 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor2VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.25 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor2VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.26 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor30Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.44 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor30VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.81 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor30VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.82 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor3Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.14 | OCTET STRING | read-only | Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor3Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.17 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor3VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.27 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor3VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.28 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor4Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.15 | OCTET STRING | read-only | Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor4Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.18 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor4VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.29 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor4VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.30 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor5Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.16 | OCTET STRING | read-only | Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor5Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.19 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor5VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.31 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor5VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.32 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor6Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.17 | OCTET STRING | read-only | Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor6Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.20 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor6VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.33 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor6VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.34 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor7Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.18 | OCTET STRING | read-only | Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor7Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.21 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor7VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.35 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor7VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.36 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor8Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.19 | OCTET STRING | read-only | Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor8Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.22 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor8VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.37 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor8VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.38 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor9Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.20 | OCTET STRING | read-only | Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor9Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.23 | OCTET STRING | read-only | Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor9VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.39 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| OCT bladeSensor9VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.40 | OCTET STRING | read-only | Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| INT bladeSensorTempCapability | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.11 | INTEGER | read-only | Indicates whether the server blade is IPMI capable or not. |
| INT bladeSensorVoltCapability | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.14 | INTEGER | read-only | Indicates whether the server blade is IPMI capable or not. |
| INT bladeServerExpansion | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.14 | INTEGER | read-only | This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade. |
| INT bladeServerExpansion2 | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.17 | INTEGER | read-only | This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade. |
| bladeServiceData | 1.3.6.1.4.1.2.3.51.2.23.3 | |||
| bladeServiceDataEntry | 1.3.6.1.4.1.2.3.51.2.23.3.1.1 | not-accessible | Blade service data entry | |
| bladeServiceDataTable | 1.3.6.1.4.1.2.3.51.2.23.3.1 | not-accessible | Table of blade service data information. | |
| OCT bladeSideCardMACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.164 | OCTET STRING | read-only | Blade side card MAC address 1. For consistent results, view as a table and not as individual entries. |
| OCT bladeSideCardMACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.165 | OCTET STRING | read-only | Blade side card MAC address 2. For consistent results, view as a table and not as individual entries. |
| OCT bladeSideCardMACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.166 | OCTET STRING | read-only | Blade side card MAC address 3. For consistent results, view as a table and not as individual entries. |
| OCT bladeSideCardMACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.167 | OCTET STRING | read-only | Blade side card MAC address 4. For consistent results, view as a table and not as individual entries. |
| OCT bladeSideCardMACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.168 | OCTET STRING | read-only | Blade side card MAC address 5. For consistent results, view as a table and not as individual entries. |
| OCT bladeSideCardMACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.169 | OCTET STRING | read-only | Blade side card MAC address 6. For consistent results, view as a table and not as individual entries. |
| OCT bladeSideCardMACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.170 | OCTET STRING | read-only | Blade side card MAC address 7. For consistent results, view as a table and not as individual entries. |
| OCT bladeSideCardMACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.171 | OCTET STRING | read-only | Blade side card MAC address 8. For consistent results, view as a table and not as individual entries. |
| bladeSPEthOverUSBInterface | 1.3.6.1.4.1.2.3.51.2.22.1.14 | |||
| INT bladeStatusIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.1 | INTEGER | read-only | Blade system status index. |
| OCT bladeSysMgmtProcVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.6 | OCTET STRING | read-only | The build ID for the blade firmware. |
| bladeSysMgmtProcVPDEntry | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1 | not-accessible | Blade firmware VPD table entry | |
| INT bladeSysMgmtProcVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.3 | INTEGER | read-only | Indicates whether the server blade specified exists or not. |
| INT bladeSysMgmtProcVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.2 | INTEGER | read-only | The numeric blade ID. |
| INT bladeSysMgmtProcVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.1 | INTEGER | read-only | Blade firmware VPD table index. |
| OCT bladeSysMgmtProcVpdLevelStatus | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.8 | OCTET STRING | read-only | The level status of the blade system management processor firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). |
| OCT bladeSysMgmtProcVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.5 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| INT bladeSysMgmtProcVpdPowerState | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.4 | INTEGER | read-only | Indicates the power state of the blade specified. |
| OCT bladeSysMgmtProcVpdRevision | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.7 | OCTET STRING | read-only | The revision of the blade firmware. |
| bladeSysMgmtProcVPDTable | 1.3.6.1.4.1.2.3.51.2.2.21.5.3 | not-accessible | Table of blade firmware vital product data (VPD) information. | |
| bladeSystemStatusEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1 | not-accessible | Blade system status entry | |
| bladeSystemStatusTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.1 | not-accessible | Table of blade status information. | |
| bladeTemperaturesEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1 | not-accessible | Blade temperatures table entry | |
| bladeTemperaturesTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.3 | not-accessible | Table of blade temperatures information. | |
| bladeTemperatureThresholdsEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1 | not-accessible | Blade temperature thresholds table entry | |
| bladeTemperatureThresholdsTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.4 | not-accessible | Table of blade temperature thresholds information. | |
| INT bladeTempThresholdSensorCapability | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.21 | INTEGER | read-only | Indicates whether the server blade is IPMI capable or not. |
| INT bladeVlanId | 1.3.6.1.4.1.2.3.51.2.22.1.11 | INTEGER | read-write | This is the virtual LAN ID for the internal management network between the MM and the blade system management processors (BSMPs). The range of valid VLAN ID's is 3 to 4095. |
| bladeVoltagesEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1 | not-accessible | Blade voltages table entry | |
| bladeVoltagesTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.5 | not-accessible | Table of blade voltages information. | |
| bladeVoltageThresholdsEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1 | not-accessible | Blade voltage thresholds table entry | |
| bladeVoltageThresholdsTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.6 | not-accessible | Table of blade VoltageThresholds information. | |
| INT bladeVoltThresholdSensorCapability | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.22 | INTEGER | read-only | Indicates whether the server blade is IPMI capable or not. |
| OCT bladeVRM1Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.13 | OCTET STRING | read-only | VRM 1 voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. |
| INT bladeWidth | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.15 | INTEGER | read-only | The width of the blade including any supplement blade attached to it |
| INT bootCountPowerOnTimeBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.2 | INTEGER | read-only | The numeric blade ID. |
| INT bootCountPowerOnTimeBladeIndex | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.1 | INTEGER | read-only | Blade boot count/Power On Time table index. |
| INT bootCountPowerOnTimeBoots | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.3 | INTEGER | read-write | Blade Boot Count. If there is no blade in the given slot then this value is undefined. Writing this value resets the Boot Count to zero. |
| INT bootCountPowerOnTimeSecs | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.4 | INTEGER | read-write | Blade Power On Time in seconds. If there is no blade in the given slot then this value is undefined. Writing this value resets the Power On Time to zero. |
| INT bootDeviceActive | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.4 | INTEGER | read-only | Specifies whether the boot device is active. |
| OCT bootDeviceId | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.3 | OCTET STRING | read-only | The device Id of the boot device. |
| INT bootDeviceIndex | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.2 | INTEGER | read-only | An index for the boot device for the given topology id. |
| bootDeviceInfoEntry | 1.3.6.1.4.1.2.3.51.2.22.1.15.1 | not-accessible | Boot device entry | |
| bootDeviceInfoTable | 1.3.6.1.4.1.2.3.51.2.22.1.15 | not-accessible | Table of blade boot device information. Contains info for the boot devices for each blade. | |
| OCT bootDeviceLabel | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.6 | OCTET STRING | read-only | The device label of the boot device. |
| INT bootDeviceOrder | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.8 | INTEGER | read-only | The sequence number in boot order of the boot device. 0 specifies this device is not in the boot sequence. |
| INT bootDevicePresence | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.5 | INTEGER | read-only | Specifies whether the boot device is present. |
| OCT bootDeviceUserLabel | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.7 | OCTET STRING | read-only | The user label of the boot device. |
| OCT bootInfoTopologyIndex | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.1 | OCTET STRING | read-only | The unique identifier for a node containing boot devices in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the relevant numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade |
| OCT bootSequenceInfoBootSequence | 1.3.6.1.4.1.2.3.51.2.22.1.16.1.3 | OCTET STRING | read-write | A blank delimited string of device ids in the order of the boot sequence. For example, 00000001 00000002 00000005. Note that the boot sequence list can change from a given order and can grow from a given order, but cannot be reduced in length. For example, if the sequence starts as 00000001 00000011, it could change to 00000001 00000014 or grow to 00000001 00000014 00000002. In the example above, if the 00000002 selection was no longer desired, the list should be changed to 00000001 00000014 00000014, essentially repeating the last device ID. Device ids must be listed in bootDeviceInfoTable. |
| bootSequenceInfoEntry | 1.3.6.1.4.1.2.3.51.2.22.1.16.1 | not-accessible | Boot sequence entry | |
| INT bootSequenceInfoMaxBootDevices | 1.3.6.1.4.1.2.3.51.2.22.1.16.1.2 | INTEGER | read-only | The maximum number of boot devices. |
| bootSequenceInfoTable | 1.3.6.1.4.1.2.3.51.2.22.1.16 | not-accessible | Table of blade boot sequence information. Contains the boot sequence information for each blade. | |
| OCT bootSequenceInfoTopologyIndex | 1.3.6.1.4.1.2.3.51.2.22.1.16.1.1 | OCTET STRING | read-only | The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the relevant numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade |
| callHomeExclusionEvents | 1.3.6.1.4.1.2.3.51.2.23.6 | |||
| OCT cfmThermalTrendingCurrentCFM | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.3 | OCTET STRING | read-only | Cubic Feet per Minute Thermal Trending Table The Current CFM of air flow calculated at this sample time. |
| cfmThermalTrendingEntry | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1 | not-accessible | Chassis CFM Thermal Trending entry. | |
| INT cfmThermalTrendingIndex | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.1 | INTEGER | read-only | Cubic Feet per Minute Thermal Trending Table Index. |
| OCT cfmThermalTrendingMaxCFM | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.4 | OCTET STRING | read-only | Cubic Feet per Minute Thermal Trending Table The Maximum CFM of air flow the chassis can provide at this sample time. |
| cfmThermalTrendingTable | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.60 | not-accessible | Table of Cubic Feet per Minute Thermal Trending Information. | |
| OCT cfmThermalTrendingTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.2 | OCTET STRING | read-only | Cubic Feet per Minute Thermal Trending Table Sample Timestamp. |
| INT changePasswordFirstAccess | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.7 | INTEGER | read-write | If enabled, the login user will be forced to change their password on the first access after the account has been established or on the first access after an administrator has changed the password for the user, except for the administrator password for USERID. The default value is disabled. |
| INT chassisActiveMM | 1.3.6.1.4.1.2.3.51.2.22.4.34 | INTEGER | read-only | The active management module (MM). |
| OCT chassisBayDevicesInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.25 | OCTET STRING | read-only | The bay devices that are installed in the chassis. The bay devices are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of bay devices supported. For devices that fill multiple bays, the bit mask will indicate the primary/lowest bay as occupied. If a device is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if devices are installed in bays 1, 5, and 13, and 14 bays are supported, the string would look like '10001000000010'. |
| OCT chassisClei | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.14 | OCTET STRING | read-only | Machine chassis Common Language Equipment Identification (CLEI). |
| chassisConfiguration | 1.3.6.1.4.1.2.3.51.2.2.10.5.1 | |||
| INT chassisCoolingIndex | 1.3.6.1.4.1.2.3.51.2.2.3.51.1.1 | INTEGER | read-only | Chassis Cooling Zones table index. |
| INT chassisCoolingZone | 1.3.6.1.4.1.2.3.51.2.2.3.51.1.2 | INTEGER | read-only | The cooling zone for the chassis component. |
| INT chassisCoolingZoneComponent | 1.3.6.1.4.1.2.3.51.2.2.3.51.1.4 | INTEGER | read-only | A component within a cooling zone. |
| chassisCoolingZoneEntry | 1.3.6.1.4.1.2.3.51.2.2.3.51.1 | not-accessible | Chassis cooling zone information entry | |
| INT chassisCoolingZoneStatus | 1.3.6.1.4.1.2.3.51.2.2.3.51.1.3 | INTEGER | read-only | The health state of the chassis cooling zone. Note: This is the health of the cooling zone, not the health status of the component in chassisCoolingZoneComponent. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Attention, Critical CLI - OK, Non-critical, Critical |
| chassisCoolingZoneTable | 1.3.6.1.4.1.2.3.51.2.2.3.51 | not-accessible | Table of chassis cooling zone information. | |
| INT chassisDiscovery | 1.3.6.1.4.1.2.3.51.2.22.12.2 | INTEGER | read-write | Discovery of remote Chassis. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT chassisFanControllerState | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.6 | INTEGER | read-only | The controller health state for the chassis fan. |
| chassisFanControllerVPDEntry | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1 | not-accessible | Chassis fan controller firmware VPD table entry | |
| INT chassisFanControllerVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.3 | INTEGER | read-only | Indicates whether the chassis fan specified exists or not. |
| INT chassisFanControllerVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.2 | INTEGER | read-only | The numeric chassis fan ID. |
| INT chassisFanControllerVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.1 | INTEGER | read-only | Chassis fan controller firmware VPD table index. |
| OCT chassisFanControllerVpdRevision | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.7 | OCTET STRING | read-only | The revision of the chassis fan controller firmware. |
| chassisFanControllerVPDTable | 1.3.6.1.4.1.2.3.51.2.2.21.12.1 | not-accessible | Table of chassis fan controller firmware vital product data (VPD) information. | |
| INT chassisFanCoolingZone | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.7 | INTEGER | read-only | The cooling zone for the chassis fan. |
| chassisFanDetails | 1.3.6.1.4.1.2.3.51.2.2.10.4.3 | |||
| chassisFanFirmwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.12 | |||
| chassisFanHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.13 | |||
| OCT chassisFanHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.2 | OCTET STRING | read-only | Chassis fan hardware VPD Bay number. |
| OCT chassisFanHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.15 | OCTET STRING | read-only | Chassis fan hardware VPD Common Language Equipment Identifier (CLEI). |
| chassisFanHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1 | not-accessible | Chassis fan hardware VPD entry. | |
| OCT chassisFanHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.4 | OCTET STRING | read-only | Chassis fan hardware VPD FRU number. |
| OCT chassisFanHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.11 | OCTET STRING | read-only | Chassis fan hardware VPD FRU serial number. |
| INT chassisFanHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.5 | INTEGER | read-only | Chassis fan hardware VPD hardware revision. |
| OCT chassisFanHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.16 | OCTET STRING | read-only | Chassis fan hardware VPD hardware revision in string format. |
| INT chassisFanHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.1 | INTEGER | read-only | Chassis fan hardware VPD index. |
| OCT chassisFanHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.3 | OCTET STRING | read-only | Chassis fan hardware VPD manufacturing ID. |
| OCT chassisFanHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.12 | OCTET STRING | read-only | Chassis fan hardware VPD manufacturer ID. |
| OCT chassisFanHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.9 | OCTET STRING | read-only | Chassis fan hardware VPD manufacture Date. |
| OCT chassisFanHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.10 | OCTET STRING | read-only | Chassis fan hardware VPD Part Number. |
| OCT chassisFanHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.13 | OCTET STRING | read-only | Chassis fan hardware VPD product ID. |
| OCT chassisFanHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.14 | OCTET STRING | read-only | Chassis fan hardware VPD subsystem manufacturer ID. |
| chassisFanHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.13.1 | not-accessible | Table of the chassis fan hardware components. | |
| OCT chassisFanHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.8 | OCTET STRING | read-only | Chassis fan hardware VPD UUID. |
| INT chassisFanId | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.2 | INTEGER | read-only | The numeric chassis fan ID. |
| INT chassisFanIndex | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.1 | INTEGER | read-only | Chassis Fans table index. |
| chassisFanLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.5 | |||
| chassisFanLEDsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1 | not-accessible | Chassis fan LEDs information entry | |
| chassisFanLEDsTable | 1.3.6.1.4.1.2.3.51.2.2.8.5.1 | not-accessible | Table of chassis fan LEDs information. | |
| chassisFanPowerTrending | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3 | |||
| INT chassisFanPowerTrendingId | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.2 | INTEGER | read-write | Chass fan mModule power trending fan ID. NOTE: The ID should be configured before displaying the chassisFanPowerTrendingTable. |
| INT chassisFanPowerTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.1 | INTEGER | read-write | Specify time period for chassis fan module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for chassis fan module. |
| OCT chassisFanPowerTrendingSampleAve | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.6 | OCTET STRING | read-only | Chassis fan Module Power Trending Sample Table Average Power. |
| chassisFanPowerTrendingSampleEntry | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1 | not-accessible | Chassis fan Module Power Trending Sample entry. | |
| INT chassisFanPowerTrendingSampleId | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.2 | INTEGER | read-only | Chassis fan Module Power Trending Sample Table Id. |
| INT chassisFanPowerTrendingSampleIndex | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.1 | INTEGER | read-only | Chassis fan Module Power Trending Sample Table Index. |
| OCT chassisFanPowerTrendingSampleMax | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.4 | OCTET STRING | read-only | Chassis fan Module Power Trending Sample Table Maximum Power. |
| OCT chassisFanPowerTrendingSampleMin | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.5 | OCTET STRING | read-only | Chassis fan Module Power Trending Sample Table Minimum Power. |
| chassisFanPowerTrendingSampleTable | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10 | not-accessible | Table of chassis fan Module Power Trending Information. | |
| OCT chassisFanPowerTrendingSampleTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.3 | OCTET STRING | read-only | Chassis fan Module Power Trending Sample Table Timestamp. |
| chassisFans | 1.3.6.1.4.1.2.3.51.2.2.3 | |||
| chassisFansEntry | 1.3.6.1.4.1.2.3.51.2.2.3.50.1 | not-accessible | Chassis Fan information entry | |
| OCT chassisFansInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.33 | OCTET STRING | read-only | The chassis fans that are installed on the chassis. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of supported. If it is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if it is installed in bay 1, and 2 are supported, the string would look like '10'. |
| OCT chassisFanSpeed | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.3 | OCTET STRING | read-only | Chassis fan speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the chassis fan is determined not to be running or the chassis fan speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. |
| OCT chassisFanSpeedRPM | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.5 | OCTET STRING | read-only | Chassis fan speed expressed in RPM. If the chassis fan is determined not to be running or the chassis fan speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. |
| chassisFansTable | 1.3.6.1.4.1.2.3.51.2.2.3.50 | not-accessible | Table of chassis Fan information. | |
| INT chassisFanState | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.4 | INTEGER | read-only | The health state for the chassis fan. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Attention, Critical CLI - OK, Non-critical, Critical |
| INT chassisFlags | 1.3.6.1.4.1.2.3.51.2.22.4.2 | INTEGER | read-only | Chassis flags. 1 = a server blade chassis, 0 = a rack or standalone chassis. |
| OCT chassisFPsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.37 | OCTET STRING | read-only | This object is deprecated because the power modules' fan packs are integrated into the power modules and are not removable as on previous power modules. The fan packs that are installed on the chassis. The fan packs are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of fan packs supported. If a fan pack is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if fan packs are installed in bays 1 and 3, and 4 fan packs are supported, the string would look like '1010'. NOTE: Fan packs are also referred to as Power Module Cooling Devices. |
| OCT chassisFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.7 | OCTET STRING | read-only | Machine chassis FRU number. |
| OCT chassisFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.10 | OCTET STRING | read-only | Machine chassis FRU serial number. |
| INT chassisHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.6 | INTEGER | read-only | Machine chassis hardware revision. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. |
| OCT chassisHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.16 | OCTET STRING | read-only | Machine chassis hardware revision in string format. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. |
| chassisInformation | 1.3.6.1.4.1.2.3.51.2.2.10.5 | |||
| chassisInfoVpd | 1.3.6.1.4.1.2.3.51.2.2.21.1 | |||
| chassisInternalNetwork | 1.3.6.1.4.1.2.3.51.2.4.11 | |||
| OCT chassisLicenseKeyDescription | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.4 | OCTET STRING | read-only | The description of the license key. |
| chassisLicenseKeyEntry | 1.3.6.1.4.1.2.3.51.2.2.30.5.1 | not-accessible | Chassis License key information entry. | |
| OCT chassisLicenseKeyFeature | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.2 | OCTET STRING | read-only | The name of the Feature for the license key. |
| OCT chassisLicenseKeyFeatureType | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.3 | OCTET STRING | read-only | The Feature Type Code for the license key. |
| INT chassisLicenseKeyIndex | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.1 | INTEGER | read-only | The key index for the chassis license keys. |
| OCT chassisLicenseKeyLicenseID | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.6 | OCTET STRING | read-only | Identification of the license key. |
| INT chassisLicenseKeyStatus | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.8 | INTEGER | read-only | The current status of the license key. |
| OCT chassisLicenseKeySystem | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.5 | OCTET STRING | read-only | System information for the license key. |
| chassisLicenseKeyTable | 1.3.6.1.4.1.2.3.51.2.2.30.5 | not-accessible | Table of chassis license key information. | |
| OCT chassisLicenseKeyTimeLimit | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.9 | OCTET STRING | read-only | Date and Time (GMT) when license expires. |
| INT chassisLicenseKeyUsageLimit | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.10 | INTEGER | read-only | Number of times remaining for license usage. A negative value indicates that there is no Usage Limit for the license. |
| OCT chassisLicenseKeyValidation | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.7 | OCTET STRING | read-only | Validation of the license key. |
| INT chassisLowestU | 1.3.6.1.4.1.2.3.51.2.22.4.56 | INTEGER | read-write | The lowest U position that is occupied in the rack. |
| OCT chassisManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.5 | OCTET STRING | read-only | Machine chassis manufacturing ID. |
| OCT chassisManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.11 | OCTET STRING | read-only | Machine chassis manufacturer ID Number. |
| OCT chassisManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.8 | OCTET STRING | read-only | Machine chassis manufacture date. |
| OCT chassisMMsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.30 | OCTET STRING | read-only | The management modules that are installed on the chassis. The management modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of management modules supported. If a management module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a management module is installed in bay 1, and 2 management modules are supported, the string would look like '10'. |
| OCT chassisName | 1.3.6.1.4.1.2.3.51.2.22.4.54 | OCTET STRING | read-write | The name of the chassis. Maximum 15 character long plus NULL termination. |
| INT chassisNoOfBayDevicesSupported | 1.3.6.1.4.1.2.3.51.2.22.4.19 | INTEGER | read-only | Maximum number of bays found in the chassis. |
| INT chassisNoOfChassisFansSupported | 1.3.6.1.4.1.2.3.51.2.22.4.24 | INTEGER | read-only | Number of chassis fans supported. |
| INT chassisNoOfFPsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.18 | INTEGER | read-only | This object is deprecated because the power modules' fan packs are integrated into the power modules and are not removable as on previous power modules. Number of fan packs (FPs) supported. NOTE: Fan packs are also referred to as Power Module Cooling Devices. |
| INT chassisNoOfMMsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.21 | INTEGER | read-only | Number of management modules (MMs) supported. |
| INT chassisNoOfPMsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.22 | INTEGER | read-only | Number of power modules (PMs) supported. |
| OCT chassisNoOfRearLEDCardsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.52 | OCTET STRING | read-only | The rear LED cards that are installed on the chassis. |
| INT chassisNoOfRearLEDCardsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.23 | INTEGER | read-only | Number of rear LED cards supported. |
| INT chassisNoOfSMsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.20 | INTEGER | read-only | Number of switch modules (SMs) supported. |
| OCT chassisPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.9 | OCTET STRING | read-only | Machine chassis part number. |
| OCT chassisPMsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.31 | OCTET STRING | read-only | The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'. |
| INT chassisPowerService | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.5 | INTEGER | read-only | The chassis power service mode. NOTE: This MIB object is for BCS only. This object has been deprecated. See the object, powerModuleDescription, for similar information. |
| chassisPowerTrending | 1.3.6.1.4.1.2.3.51.2.2.10.5.3 | |||
| INT chassisPowerTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.1 | INTEGER | read-write | Specify time period of power trending information. NOTE: This time period should be configured before displaying the following Power Trending Information table for Chassis. |
| OCT chassisPowerTrendingSampleAve | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.3 | OCTET STRING | read-only | Chassis Power Trending Sample Average Power in specified time period. |
| chassisPowerTrendingSampleEntry | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1 | not-accessible | Chassis Power Trending Sample entry in specified time period. | |
| INT chassisPowerTrendingSampleIndex | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.1 | INTEGER | read-only | Chassis Power Trending Sample Index in specified time period. |
| chassisPowerTrendingSampleTable | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10 | not-accessible | Table of Chassis Power Trending Sample Information in specified time period. | |
| OCT chassisPowerTrendingSampleTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.2 | OCTET STRING | read-only | Chassis Power Trending Sample Timestamp in specified time period. |
| OCT chassisProductId | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.12 | OCTET STRING | read-only | Machine chassis product ID. |
| OCT chassisRack | 1.3.6.1.4.1.2.3.51.2.22.4.55 | OCTET STRING | read-write | The name of the room where the chassis is located. Maximum 23 characters for name plus NULL termination. |
| INT chassisRearLEDCardInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.32 | INTEGER | read-only | Indicates whether at least one rear LED card is installed. |
| INT chassisResponseVersion | 1.3.6.1.4.1.2.3.51.2.22.4.1 | INTEGER | read-only | Chassis response version. |
| OCT chassisRoom | 1.3.6.1.4.1.2.3.51.2.22.4.53 | OCTET STRING | read-write | The name of the room where the chassis is located. Maximum 23 characters for name plus NULL termination. |
| chassisSecuritySettings | 1.3.6.1.4.1.2.3.51.2.4.3.5 | |||
| OCT chassisSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.3 | OCTET STRING | read-write | Machine serial number VPD information (from System BIOS). This field must be seven alpha numeric characters. |
| OCT chassisSMsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.29 | OCTET STRING | read-only | The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011'. |
| OCT chassisSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.13 | OCTET STRING | read-only | Machine chassis subsystem manufacturer. |
| INT chassisSubtype | 1.3.6.1.4.1.2.3.51.2.22.4.39 | INTEGER | read-only | The subtype of the chassis. This MIB object should be used in conjunction with chassisType MIB object to determine the characteristic of the chassis. |
| chassisThermalTrending | 1.3.6.1.4.1.2.3.51.2.2.10.5.5 | |||
| INT chassisThermalTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.1 | INTEGER | read-write | Specify time period of thermal trending information. NOTE: This time period should be configured before displaying the following Thermal Trending Information table for Chassis. |
| chassisTopology | 1.3.6.1.4.1.2.3.51.2.22.4 | |||
| OCT chassisTotalDCPowerAvailable | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.1 | OCTET STRING | read-only | Chassis total DC power available, which displays the total DC power available for the entire chassis. It is the sum of the two power domains. |
| OCT chassisTotalPowerInUsed | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.2 | OCTET STRING | read-only | Chassis total power being used, which displays the total power being consumed by all modules in the chassis. It also includes power consumed by the blowers (chassis cooling devices) for the chassis. |
| OCT chassisTotalThermalOutput | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.3 | OCTET STRING | read-only | Chassis total thermal output, which displays the thermal output (load) in BTUs per hour. It is calculated based on the total input power in use. (1 Watt = 3.412 BTU/hour). |
| INT chassisType | 1.3.6.1.4.1.2.3.51.2.22.4.38 | INTEGER | read-only | The type of the chassis. This MIB object should be used in conjunction with chassisSubType MIB object to determine the characteristic of the chassis. |
| INT chassisUHeight | 1.3.6.1.4.1.2.3.51.2.22.4.57 | INTEGER | read-only | The height of the chassis in 'U' units. |
| OCT chassisUUID | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.4 | OCTET STRING | read-write | Machine UUID (Universal Unique ID information) (from System BIOS). This field must be 32 alpha numeric characters. |
| chassisVpd | 1.3.6.1.4.1.2.3.51.2.2.21.1.1 | |||
| OCT chassisVpdMachineModel | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.2 | OCTET STRING | read-write | Machine model VPD information (from System BIOS). This field must be three alpha numeric characters. |
| OCT chassisVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.1 | OCTET STRING | read-write | Machine type VPD information (from System BIOS). This field must be four alpha numeric characters. |
| INT checkLogLED | 1.3.6.1.4.1.2.3.51.2.2.8.1.2 | INTEGER | read-write | Indicates whether the front panel system information LED is on or off. For Write access, the LED can be turned off only. |
| INT cimEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.50 | INTEGER | read-write | Disable/Enable CIM (Common Information Model) interface. NOTE: Change to CIM enable/disable will take effect immediately. |
| INT cimPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.50 | INTEGER | read-write | CIM (Common Information Model) port number. Default value is 5989. Port change will take effect immediately. |
| INT cinDefExists | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.2 | INTEGER | read-only | Indicates if a Chassis Internal Network (CIN) definition exists for this index or not. |
| INT cinDelete | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.3 | INTEGER | read-write | Delete Chassis Internal Network (CIN) definition. Works like CIN entry disabled. However, the entry is also deleted. NOTE: Value returned for the GET command is meaningless for this MIB object. Deleting a non-defined entry does nothing. |
| INT cinEnable | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.4 | INTEGER | read-write | Disable or enable a Chassis Internal Network (CIN) definition. Enabled: MM reads the entry and creates a new CIN interface if the CIN VLAN ID is new and does not have a CIN interface created yet, adds host route, and monitors communication path. Start ARP monitoring if IP is 0.0.0.0. Disabled: Delete host route. If this is the last IP address that uses the CIN interface, - Stop ARP monitoring if IP is 0.0.0.0. - Delete the CIN interface if there is no other entry depends on it. |
| cinEntry | 1.3.6.1.4.1.2.3.51.2.4.11.3.1 | not-accessible | Chassis Internal Network (CIN) table entry. | |
| INT cinGlobalEnable | 1.3.6.1.4.1.2.3.51.2.4.11.2 | INTEGER | read-write | Disable/Enable Chassis Internal Network (CIN) function dynamically. Enabled: MM reads the CIN entries. For each enabled entry, - If the CIN VLAN ID is new and does not have a CIN interface created yet then create a new CIN interface based on that CIN VLAN ID. Use the CIN IP address from the entry to create a host route. - If the CIN IP address is 0.0.0.0 then start ARP monitoring. Disabled: - Stop all ARP monitoring. - Delete all host routes. - Delete all CIN interfaces. |
| INT cinId | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.5 | INTEGER | read-write | This is the Chassis Internal Network (CIN) Virtual LAN (VLAN) ID for the internal management network between the Management Module, I/O Module, and the blade OS. The range of valid CIN VLAN IDs is 3 to 4094 (inclusive). This value cannot be the same as the Serial Over LAN (SOL) or Concurrent KVM (cKVM) VLAN ID. NOTE: If creating a new CIN definition, you must define cinId before you define cinIpAddress. NOTE: Before changing this value on an existing CIN definition, you must first disable the definition. |
| INT cinIndex | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.1 | INTEGER | read-only | Chassis Internal Network (CIN) table index. |
| IP cinIpAddress | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.6 | IpAddress | read-write | Chassis Internal Network (CIN) IP address. Restrictions: - CIN entries cannot have matching IP addresses, with the exception of 0.0.0.0. - Multiple IP addresses of 0.0.0.0 with different VLAN IDs are allowed. - The IP address cannot be multi-cast. - The IP address cannot match the MM IP address. - If the CIN IP address is 0.0.0.0, the blade IP address for CIN which is configured in the blade's OS can not be in the same subnet as that of MM. NOTE: If creating a new CIN definition, you must define cinId before you define cinIpAddress. NOTE: Before changing this value on an existing CIN definition, you must first disable the definition. NOTE: When ipv6 is enable on one interface, this column will display all zero IPv4 address |
| ADR cinIpv6Address | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.7 | InetAddressIPv6 | read-write | Chassis Internal Network (CIN) IPv6 address NOTE: When ipv4 is enable on one interface,this column will display all zero IPv6 address. |
| INT cinsSupported | 1.3.6.1.4.1.2.3.51.2.4.11.1 | INTEGER | read-only | Number of Chassis Internal Network (CIN) definitions supported. Currently a maximum of 14 CIN definitions can be supported. |
| cinStatus | 1.3.6.1.4.1.2.3.51.2.4.11.4 | |||
| cinStatusEntry | 1.3.6.1.4.1.2.3.51.2.4.11.4.1.1 | not-accessible | Chassis Internal Network (CIN) status table entry. | |
| INT cinStatusIndex | 1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.1 | INTEGER | read-only | The Chassis Internal Network (CIN) status log index number. For consistent results, view as a table and not as individual entries. |
| OCT cinStatusString | 1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.2 | OCTET STRING | read-only | Status of a Chassis Internal Network (CIN) connection. For example: Index:1 VLANID:4094 IPADDR:192.168.70.100 MAC:01:0A:0B:00:01:01 Type:Learned Status:Operational Index is the status entry number in the status table. Followed by the VLAN ID, IP address, and MAC address that the Management Module is communicating with on the CIN connection. Type is either 'Configured' or 'Learned'. Learned implies that the Management Module dynamically discovered the IP address. Configured means that the address was explicitly configured in the Management Module. Status can be 'Operational', 'Not Operational', or 'Disabled'. 'Operational' means the Management Module can ping the CIN IP address. 'Not Operational' means that the Management Module cannot ping the CIN IP address. Verify that the blade and I/O Module are configured properly and that their configurations are compatible with the Management Module. The blade OS also needs to have an IP host route defined (e.g. route add -host 192.168.70.100 eth0.4094). I/O Modules need to have a VLAN defined containing the blade's and the MM's port. Blade and I/O Modules need to be powered up and operational. 'Disabled' means that the CIN configuration has been disabled by a Management Module administrator. For consistent results, view as a table and not as individual entries. |
| cinStatusTable | 1.3.6.1.4.1.2.3.51.2.4.11.4.1 | not-accessible | Table of Chassis Internal Network (CIN) status entry information. | |
| cinTable | 1.3.6.1.4.1.2.3.51.2.4.11.3 | not-accessible | Chassis Internal Network (CIN) configuration table. | |
| INT cipherStrength | 1.3.6.1.4.1.2.3.51.2.4.3.5.15 | INTEGER | read-write | Strength level of the NIST signing algorithm for certificate authority. None(0) indicates no signing algorithm has been set. When writing a new value to this object, a result of No Error is returned if the value is valid. However, the new algorithm will be used to create an authority certificate asynchronously. This process may take up to 1 minute to complete. So results for subsequent queries to the object's value may also be delayed while the new certificate is being generated. |
| OCT city | 1.3.6.1.4.1.2.3.51.2.23.4.3.6 | OCTET STRING | read-write | The city of the machine location. 1-30 characters. |
| INT clearAuditLog | 1.3.6.1.4.1.2.3.51.2.3.4.11 | INTEGER | read-write | Clear the audit log. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT clearEventLog | 1.3.6.1.4.1.2.3.51.2.3.4.3 | INTEGER | read-write | Clear the event log. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT clearSystemLog | 1.3.6.1.4.1.2.3.51.2.3.4.13 | INTEGER | read-write | Clear the system log. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT cli | 1.3.6.1.4.1.2.3.51.2.4.1.5.1 | INTEGER | read-write | Enable/Disable CLI access to the MM (telnet and SSH). The value enabled(3) means both telnet and ssh are enabled. |
| OCT cmeChassisFru | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.11 | OCTET STRING | read-only | Chassis Field-Replaceable number. |
| OCT cmeChassisFruList | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.21 | OCTET STRING | read-only | Chassis FRU list. |
| OCT cmeChassisId | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.16 | OCTET STRING | read-only | Chassis ID. |
| OCT cmeChassisLocation | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.17 | OCTET STRING | read-only | Chassis location information. |
| OCT cmeChassisMachineTypeMode | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.12 | OCTET STRING | read-only | Chassis machine type and model number. |
| OCT cmeChassisMidPid | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.15 | OCTET STRING | read-only | Chassis mid-plane ID. |
| OCT cmeChassisRackId | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.19 | OCTET STRING | read-only | Chassis rack ID. |
| OCT cmeChassisRoomId | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.18 | OCTET STRING | read-only | Chassis room ID. |
| OCT cmeChassisSerial | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.10 | OCTET STRING | read-only | Chassis serial number. |
| OCT cmeChassisType | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.23 | OCTET STRING | read-only | Chassis type. |
| OCT cmeChassisUser | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.20 | OCTET STRING | read-only | Chassis user information. |
| OCT cmeChassisUuid | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.14 | OCTET STRING | read-only | Chassis UUID. |
| OCT cmeFirmwareVersion | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.22 | OCTET STRING | read-only | Firmware version of the discovery management module. |
| OCT cmeFru | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.5 | OCTET STRING | read-only | Management module Field-Replaceable number. |
| OCT cmeIpv4Addresses | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.25 | OCTET STRING | read-only | The IPv4 addresses configured for the chassis. |
| OCT cmeIpv4AddressesFloat | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.26 | OCTET STRING | read-only | The floating IPv4 addresses configured for the chassis. |
| OCT cmeIpv4Protocols | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.27 | OCTET STRING | read-only | The IPv4 protocols configured for the chassis. |
| INT cmeIpv4Status | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.24 | INTEGER | read-only | A flag to state if IPv4 is enabled |
| OCT cmeIpv6Addresses | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.29 | OCTET STRING | read-only | The IPv6 addresses configured for the chassis. |
| OCT cmeIpv6AddressesFloat | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.30 | OCTET STRING | read-only | The floating IPv6 addresses configured for the chassis. |
| OCT cmeIpv6Protocols | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.31 | OCTET STRING | read-only | The IPv6 protocols configured for the chassis. |
| INT cmeIpv6Status | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.28 | INTEGER | read-only | A flag to state if IPv6 is enabled |
| OCT cmeMacAddress | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.9 | OCTET STRING | read-only | Management module MAC address. |
| OCT cmeMidPid | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.8 | OCTET STRING | read-only | Management module Mid-plane Pid. |
| cmeRemoteChassis | 1.3.6.1.4.1.2.3.51.2.22.12 | |||
| cmeRemoteChassisEntry | 1.3.6.1.4.1.2.3.51.2.22.12.1.1 | not-accessible | Remote chassis entry | |
| INT cmeRemoteChassisIndex | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.1 | INTEGER | read-only | Remote chassis discovery sequence index. |
| cmeRemoteChassisTable | 1.3.6.1.4.1.2.3.51.2.22.12.1 | not-accessible | This table is used to provide the discovered MMs based on the new, extended SLP response information. | |
| OCT cmeSerial | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.4 | OCTET STRING | read-only | Management module serial number. |
| OCT cmeSlot | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.7 | OCTET STRING | read-only | Management module slot. |
| OCT cmeSystemName | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.2 | OCTET STRING | read-only | System name for this discovery management module. |
| INT cmeSystemStatus | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.13 | INTEGER | read-only | Chassis status. |
| OCT cmeType | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.3 | OCTET STRING | read-only | Management module service processor type. |
| OCT cmeUuid | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.6 | OCTET STRING | read-only | Management module UUID. |
| INT cmmCentralManagerIPMISNMPv3 | 1.3.6.1.4.1.2.3.51.2.4.1.4.9 | INTEGER | read-write | Indicates whether CMM is the central manager of the IPMI and SNMPv3 accounts. For a write, it can only be set to enabled. Once the CMM state is enabled, it can only be cleared by doing a reset to defaults. WARNING: Enabling CMM IPMI/SNMPv3 user account management will cause all presently existing IPMI/SNMPv3 user accounts on nodes to be overwritten. Please be sure to save any existing node IPMI/SNMPv3 account information before proceeding. |
| OCT cmmTemp | 1.3.6.1.4.1.2.3.51.2.2.1.1.2 | OCTET STRING | read-only | This field is deprecated. The return value of this field is the same as rearLEDCardTemp. Chassis management module temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. |
| INT commandModeEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.4 | INTEGER | read-write | Set TCP Command Mode number of connections. MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. |
| INT commandModeInactivityTimeout | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.2 | INTEGER | read-write | The amount of time in seconds before the (Secure)TCP Command Mode times out. Default value of 0 means no timeout. Max value is any positive 4 byte value. |
| INT commandModePortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.8 | INTEGER | read-write | TCP Command Mode port number. Default value is 6090. Change will take effect immediately. |
| OCT companyName | 1.3.6.1.4.1.2.3.51.2.23.4.3.1 | OCTET STRING | read-write | The organization/company name of the contact person. 1-30 characters. |
| INT complexPasswordRules | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.5 | INTEGER | read-write | If enabled, the minimum complexity rules will be enforced for all local login passwords and 'User login password required' rule will be enabled. The complex rules are as follows: must be 8-31 characters must contain at least one number must contain at least one letter cannot contain white space characters cannot be a repeat or reverse of user name no more than 3 of the same characters used consecutively must contain at least 2 of the following combinations: at least one upper case letter at least one lower case letter at least one special character Password and password confirm values must match If disabled, the lagacy rules are: must be 5-31 characters must contain at least one number must contain at least one letter cannot contain white space characters Password and password confirm values must match The default value is disabled. |
| OCT componentBayData | 1.3.6.1.4.1.2.3.51.2.22.32.1.1.4 | OCTET STRING | read-write | A null terminated string that defines the component Bay Data. This data is puched to the components's BSMP and SMBIOS structures, where it can be used by the components's OS. Up to 60 characters can be defined plus a Null terminator. |
| componentBayDataEntry | 1.3.6.1.4.1.2.3.51.2.22.32.1.1 | not-accessible | Component Bay Data table entry | |
| OCT componentBayDataName | 1.3.6.1.4.1.2.3.51.2.22.32.1.1.2 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| INT componentBayDataStatus | 1.3.6.1.4.1.2.3.51.2.22.32.1.1.3 | INTEGER | read-only | This shows Bay Data (BD) Status. 0 means the component fully supports BD. 1 means that the component's BIOS does not support BD. 2 means that there is no component in the bay. 3 means that the component is being discovered. 255 means that the component does not support BBD. |
| componentBayDataTable | 1.3.6.1.4.1.2.3.51.2.22.32.1 | not-accessible | Table of component bay User data information. Contains user provided data for each component bay. | |
| INT componentBayDataTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.32.2 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentBayDataTable. This value is static (constant) and cannot be set. |
| OCT componentBayDataTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.32.1.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| componentConfiguration | 1.3.6.1.4.1.2.3.51.2.22.32 | |||
| INT componentConfigurationActiveBootMode | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.3 | INTEGER | read-only | Indicates the active copy of the firmware from which the component is booting. NOTE: Some components do not support the automatic boot recovery. It displays 'notApplicable' for such components. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible. |
| INT componentConfigurationAutoPowerOn | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.5 | INTEGER | read-write | Component auto-power on policy. - restore: component will be powered on which were previously on. - auto: component will automatically be powered on when power is applied to the chassis. - manual: component will be left off until manually powered on by the user. - notApplicable: is a read-only value, this value cannot be set. |
| componentConfigurationEntry | 1.3.6.1.4.1.2.3.51.2.22.32.11.1 | not-accessible | Component configuration table entry | |
| INT componentConfigurationLocalPowerControlEnable | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.7 | INTEGER | read-write | Component local power control enablement status. |
| OCT componentConfigurationName | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.2 | OCTET STRING | read-write | The name of the component as a null terminated string. This object is configurable. |
| INT componentConfigurationPendingBootMode | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.4 | INTEGER | read-write | Indicates the copy of the firmware from which the component will boot after the next reboot. NOTE: Some components do not support the automatic boot recovery. It displays 'notApplicable' for such components and the value can not be set. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible. |
| INT componentConfigurationPowerOnRestartDelay | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.6 | INTEGER | read-write | Restart delay (in seconds) when power is applied to a component. |
| componentConfigurationTable | 1.3.6.1.4.1.2.3.51.2.22.32.11 | not-accessible | Table of component configuration information. | |
| INT componentConfigurationTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.32.12 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentConfigurationTable. This value is static (constant) and cannot be set. |
| OCT componentConfigurationTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| INT componentConfigurationWakeOnLanControlEnable | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.8 | INTEGER | read-write | Component Wake On LAN enablement status. If WOL is not supported by the component, it displays 'notApplicable' and WOL can not be enabled or disabled. |
| INT componentDHCPv6ConfigEnabled | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.6 | INTEGER | read-write | Enables/Disables DHCPv6 address configuration support on the component. |
| OCT componentDriveDescription | 1.3.6.1.4.1.2.3.51.2.2.23.10.1.2 | OCTET STRING | read-only | A short text string describing the particular drive on the component. |
| componentDriveEntry | 1.3.6.1.4.1.2.3.51.2.2.23.10.1 | not-accessible | Component drive information. | |
| componentDriveTable | 1.3.6.1.4.1.2.3.51.2.2.23.10 | not-accessible | Table of information indicating presence of a disk drive on a component. The management module does not receive any inventory VPD from the component, so only the presence of a drive can be indicated by this table. | |
| INT componentDriveTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.2.23.11 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentDriveTable. This value is static (constant) and cannot be set. |
| OCT componentDriveTopologyPath | 1.3.6.1.4.1.2.3.51.2.2.23.10.1.1 | OCTET STRING | read-only | The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card |
| INT componentEthOverUSBInterfaceEnable | 1.3.6.1.4.1.2.3.51.2.22.32.6.1.3 | INTEGER | read-write | This object allows the user to view the status of, and enable or disable, a component's interface on Ethernet-over-USB. NOTE: If the component either does not exist or does not support Ethernet-over-USB command interface. It displays 'notApplicable'. NOTE: It will take about 10 or more seconds for the disable/enable setting to take effect. |
| componentEthOverUSBInterfaceEntry | 1.3.6.1.4.1.2.3.51.2.22.32.6.1 | not-accessible | Blade Service Processor's Ethernet over USB interface entry. | |
| OCT componentEthOverUSBInterfaceName | 1.3.6.1.4.1.2.3.51.2.22.32.6.1.2 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| componentEthOverUSBInterfaceTable | 1.3.6.1.4.1.2.3.51.2.22.32.6 | not-accessible | Table of blade Service Processor's Ethernet over USB interface. | |
| INT componentEthOverUSBInterfaceTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.32.7 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentEthOverUSBInterfaceTable. This value is static (constant) and cannot be set. |
| OCT componentEthOverUSBInterfaceTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.32.6.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| componentFirmware | 1.3.6.1.4.1.2.3.51.2.2.23.2 | |||
| OCT componentFirmwareBuildID | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.6 | OCTET STRING | read-only | A text description of the build identifier for this firmware load. |
| OCT componentFirmwareComponentDescription | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.4 | OCTET STRING | read-only | A short text string describing the particular component. For the MM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object. |
| INT componentFirmwareComponentInstance | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.3 | INTEGER | read-only | The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentFirmwareTopologyPath object, but this componentFirmwareComponentInstance object is provided as a convenience to the user. |
| componentFirmwareEntry | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1 | not-accessible | Component firmware information. | |
| OCT componentFirmwareFilename | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.8 | OCTET STRING | read-only | A text description of the filename of this firmware load. |
| INT componentFirmwareImageStatus | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.17 | INTEGER | read-only | This object indicates whether this firmware image is the active (1) firmware,otherwise this firmware image is inactive (0). |
| INT componentFirmwareIndex | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.2 | INTEGER | read-only | Each component may have one or more types of firmware associated with it, and this index object identifies the particular instance. |
| OCT componentFirmwareLevelStatus | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.12 | OCTET STRING | read-only | The level status of the firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). |
| OCT componentFirmwarePendingBuildID | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.13 | OCTET STRING | read-only | A text description of the build identifier for this pending firmware load. |
| OCT componentFirmwarePendingReleaseDate | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.14 | OCTET STRING | read-only | A text description of the release date for this pending firmware load. |
| OCT componentFirmwarePendingRevision | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.15 | OCTET STRING | read-only | A text description of the revision level of this pending firmware load. |
| OCT componentFirmwareReleaseDate | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.7 | OCTET STRING | read-only | A text description of the release date for this firmware load. |
| OCT componentFirmwareReleaseLevel | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.16 | OCTET STRING | read-only | A text description of the firmware release level this firmware load. |
| OCT componentFirmwareRevision | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.9 | OCTET STRING | read-only | A text description of the revision level of this firmware load. |
| INT componentFirmwareRevisionMajor | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.10 | INTEGER | read-only | A numeric identifier of the revision major number for this firmware load. |
| INT componentFirmwareRevisionMinor | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.11 | INTEGER | read-only | A numeric identifier of the revision minor number for this firmware load. |
| OCT componentFirmwareRole | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.18 | OCTET STRING | read-only | A text description with the firmware image information. |
| componentFirmwareTable | 1.3.6.1.4.1.2.3.51.2.2.23.2.1 | not-accessible | Table of component firmware information. Not all components will provide every object defined in the ComponentFirmwareEntry. | |
| INT componentFirmwareTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.2.23.2.2 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentFirmwareTable. This value is static (constant) and cannot be set. |
| OCT componentFirmwareTopologyPath | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX, 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| OCT componentFirmwareType | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.5 | OCTET STRING | read-only | A text description of the type of firmware load. |
| INT componentFirmwareTypeID | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.20 | INTEGER | read-only | Indicates the type of firmware load with a numeric identifier. |
| INT componentHealthEventIndex | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.2 | INTEGER | read-only | An index for the critical or warning health events for a given component. |
| OCT componentHealthSummaryDateTime | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.6 | OCTET STRING | read-only | System health summary date time of an event for the given component. |
| OCT componentHealthSummaryDescription | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.5 | OCTET STRING | read-only | System health summary description of an event for the given component. |
| componentHealthSummaryEntry | 1.3.6.1.4.1.2.3.51.2.22.37.6.1 | not-accessible | Component health summary entry | |
| OCT componentHealthSummaryEventID | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.7 | OCTET STRING | read-only | System health summary event ID of an event for the given component. |
| OCT componentHealthSummaryName | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.3 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| OCT componentHealthSummarySeverity | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.4 | OCTET STRING | read-only | System health summary severity of an event for the given component. |
| componentHealthSummaryTable | 1.3.6.1.4.1.2.3.51.2.22.37.6 | not-accessible | Table of component health summary information. Contains information about the overall component health status. Each component contains a list of critical or warning events for that component or severity of good or none if none exist. | |
| INT componentHealthSummaryTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.37.7 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentHealthSummaryTable. This value is static (constant) and cannot be set. |
| OCT componentHealthTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| componentInformation | 1.3.6.1.4.1.2.3.51.2.2.23 | |||
| componentInventory | 1.3.6.1.4.1.2.3.51.2.2.23.1 | |||
| OCT componentInventoryAssetID | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.6 | OCTET STRING | read-only | The asset identifier of this component, typically set by some other authority than the manufacturer. |
| OCT componentInventoryAssetTag | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.17 | OCTET STRING | read-only | The asset tag of this component. |
| OCT componentInventoryCLEI | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.16 | OCTET STRING | read-only | The Common Language Equipment Identifier (CLEI) of this component. |
| OCT componentInventoryDescription | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.3 | OCTET STRING | read-only | A short text string describing the particular component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object in this table or the componentXXXXName object of any of the other component tables under the 'components' section of the MIB. |
| componentInventoryEntry | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1 | not-accessible | Component inventory information. | |
| OCT componentInventoryFRUNumber | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.8 | OCTET STRING | read-only | The Field Replaceable Unit (FRU) number of this component. |
| OCT componentInventoryFRUSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.9 | OCTET STRING | read-only | The Field Replaceable Unit (FRU) serial number of this component. |
| OCT componentInventoryGlobalID | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.41 | OCTET STRING | read-only | The global identifier (GLID) of this component. This ID is a unique identifier for the CMM chassis (midplane), set by the manufacturer. This ID and the associated inventory is passed back to IBM via the Electronic Service Agent and the Call Home feature. This ID and the accompanying chassis inventory will be stored and retained resulting in a configuration/change history file of the inventory for a chassis associated with a particular GLID. This ID can be used by a customer to identify and categorize all the content that resides within a chassis, much like a physical serial number is associated with a single box server. |
| OCT componentInventoryHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.11 | OCTET STRING | read-only | The hardware revision number of the this component. |
| OCT componentInventoryIdentifier | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.19 | OCTET STRING | read-only | A unique identifier assigned by the manufacturer to the component, for example, a processor ID. |
| INT componentInventoryInstance | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.2 | INTEGER | read-only | The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentInventoryTopologyPath object, but this componentInventoryInstance object is provided as a convenience to the user. |
| OCT componentInventoryMachineSerial | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.5 | OCTET STRING | read-only | The machine serial number of this component. |
| OCT componentInventoryMachineTypeModel | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.4 | OCTET STRING | read-only | The machine type and model number of this component. Typically, the format is XXXXYYY, where XXXX reprsents the machine type and YYY represents the model number. |
| OCT componentInventoryManufacture | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.10 | OCTET STRING | read-only | The text description of the manufacturer of this component. |
| OCT componentInventoryManufactureDate | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.12 | OCTET STRING | read-only | The date when the manufacturer created this component. The format is XXYY, where XX is the week number of the year 20YY. |
| INT componentInventoryManufactureIDNum | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.35 | INTEGER | read-only | The identification number assigned for the component by the manufacturer. |
| INT componentInventoryMemoryType | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.21 | INTEGER | read-only | The architecture specification of a memory device. |
| OCT componentInventoryPartNumber | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.7 | OCTET STRING | read-only | The part number of this component. |
| OCT componentInventoryProcessorCores | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.26 | OCTET STRING | read-only | The number of cores present on a processor component. |
| OCT componentInventoryProcessorDataWidth | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.34 | OCTET STRING | read-only | The maximum data bus width capability of a processor component, expressed typically in bits. |
| OCT componentInventoryProcessorExtClock | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.33 | OCTET STRING | read-only | The external clock speed of a processor component. |
| OCT componentInventoryProcessorFamily | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.25 | OCTET STRING | read-only | The family designation for processor components. |
| OCT componentInventoryProcessorL1DCache | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.28 | OCTET STRING | read-only | The level 1 data cache size of a processor component. |
| OCT componentInventoryProcessorL1ICache | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.29 | OCTET STRING | read-only | The level 1 instruction cache size of a processor component. |
| OCT componentInventoryProcessorL2Cache | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.30 | OCTET STRING | read-only | The level 2 cache size of a processor component. |
| OCT componentInventoryProcessorL3Cache | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.31 | OCTET STRING | read-only | The level 3 cache size of a processor component. |
| OCT componentInventoryProcessorThreads | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.27 | OCTET STRING | read-only | The number of threads present on a processor component. |
| INT componentInventoryProcessorType | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.24 | INTEGER | read-only | The type designation for processor components. |
| OCT componentInventoryProcessorVoltage | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.32 | OCTET STRING | read-only | The voltage rating for a processor component. |
| OCT componentInventoryProductID | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.14 | OCTET STRING | read-only | The product identifier of the component assigned by the manufacturer. |
| OCT componentInventoryProductName | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.22 | OCTET STRING | read-only | The product name assigned by the manufacturer for this component. For more detail, also refer to the componentInventoryDescription object. |
| OCT componentInventoryProductVersion | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.23 | OCTET STRING | read-only | The product version assigned by the manufacturer for this component. |
| INT componentInventoryReady | 1.3.6.1.4.1.2.3.51.2.2.23.3 | INTEGER | read-only | When a blade management controller, switch or the MM is reset, the inventory data is refreshed in the MM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the MM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication when all blades and switches have completed initialization and the inventory information has been provided to the MM. Note that due to components that may be experiencing a 'communication failure' or 'initialization failure' condition, this object may continue to show notReady. Therefore, any application that polls this object should also incorporate a timeout A more granular, per-blade status is available via the bladeSystemStatusTable |
| INT componentInventorySize | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.20 | INTEGER | read-only | A size designation for the component, for example, a memory DIMM size or hard drive capacity. |
| OCT componentInventorySpeed | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.18 | OCTET STRING | read-only | A speed designation for the component, for example, processor speed. |
| OCT componentInventorySubManufactureID | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.15 | OCTET STRING | read-only | The text sub-description of the manufacturer of this component, often used to identify a supplier for a component which has multiple suppliers. |
| componentInventoryTable | 1.3.6.1.4.1.2.3.51.2.2.23.1.1 | not-accessible | Table of component inventory information. Not all components will provide every object defined in the ComponentInventoryEntry. Also, if a component does not have inventory information or the CMM is not able to read the data from the device, then there will not be a row in this table for the component. | |
| INT componentInventoryTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.2.23.1.2 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentInventoryTable. This value is static (constant) and cannot be set. |
| OCT componentInventoryTopologyPath | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.1 | OCTET STRING | read-only | The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX, 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| OCT componentInventoryUUID | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.13 | OCTET STRING | read-only | The Universally Unique IDentifier (UUID) of this component, represented as a 16 byte hex number. |
| OCT componentIOCompatibilityComponentName | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.3 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| componentIOCompatibilityEntry | 1.3.6.1.4.1.2.3.51.2.22.37.26.1 | not-accessible | Component IO compatibility entry. | |
| OCT componentIOCompatibilityFabricOnComponent | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.6 | OCTET STRING | read-only | The fabric type for this channel on the original component (may be onboard fabric or an expansion card). |
| INT componentIOCompatibilityIOMBay | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.2 | INTEGER | read-only | An index for the IO Compatibility modules for a given component. |
| OCT componentIOCompatibilityIOMFabricType | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.5 | OCTET STRING | read-only | The fabric type of the module specified in componentIOCompatibilityIOMBay. |
| OCT componentIOCompatibilityIOMPower | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.4 | OCTET STRING | read-only | The power state of the module specified in componentIOCompatibilityIOMBay. n/a if module not installed. |
| OCT componentIOCompatibilityStatus | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.7 | OCTET STRING | read-only | The compatibility status between the component and the module specified in componentIOCompatibilityIOMBay. The possible values are: OK: No compatibility issues No IOM: There is no module on the other side of the wire for this channel on the component. n/a: (Not applicable) The module specified in componentIOCompatibilityIOMBay is a bridge, so the component port cannot connect to it. Attention: The module specified in componentIOCompatibilityIOMBay has a communication error. Mismatch: Indicates one of the following cases: Fabric types are incompatible Module specified in componentIOCompatibilityIOMBay is of unknown type Unknown fabric type on the component |
| componentIOCompatibilityTable | 1.3.6.1.4.1.2.3.51.2.22.37.26 | not-accessible | Table of component IO Compatibility information. | |
| INT componentIOCompatibilityTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.37.27 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentIOCompatibilityTable. This value is static (constant) and cannot be set. |
| OCT componentIOCompatibilityTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| INT componentIPv4ConfigDHCPEnable | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.11 | INTEGER | read-write | IP config method on the component network interface to modify mode to static IP, DHCP and 'try DHCP then try static'. If this network interface doesn't support DHCP, show 'notApplicable(255)'. |
| componentIPv4ConfigEntry | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1 | not-accessible | Component configuration table entry | |
| IP componentIPv4ConfigGatewayAddr | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.9 | IpAddress | read-write | Show or modify current IP gateway of the component network interface. Note that only if the componentIPv4ConfigPhysicalLinkStatus is 'up(1)' and the componentIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to component System Management Processor. |
| IP componentIPv4ConfigIPAddr | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.7 | IpAddress | read-write | Show/modify current IP address of the component network interface. Note that only if the componentIPv4ConfigPhysicalLinkStatus is 'up(1)' and the componentIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to component System Management Processor. |
| OCT componentIPv4ConfigMACAddr | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.12 | OCTET STRING | read-only | Show the component network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable'. |
| OCT componentIPv4ConfigName | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.3 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| INT componentIPv4ConfigPhysicalLinkState | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.6 | INTEGER | read-write | Configuration object for requesting the physical port to be either, down(0), up(1) or loopback(2). To get the current status of a physical port, use the object, componentIPv4ConfigPhysicalLinkStatus. If this network interface doesn't support up/down/loopback, show 'notApplicable(255)'. |
| INT componentIPv4ConfigPhysicalLinkStatus | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.5 | INTEGER | read-only | Indicates whether this network interface port is up or down. If this network interface doesn't support up/down, show 'notApplicable(255)'. |
| INT componentIPv4ConfigPortIndex | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.2 | INTEGER | read-only | The physical port number of the given entry. |
| OCT componentIPv4ConfigPortLabel | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.4 | OCTET STRING | read-only | Show string label that identifies the interface. |
| IP componentIPv4ConfigSubnetMask | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.8 | IpAddress | read-write | Show or modifie current subnet mask of the component network interface. Note that only if the componentIPv4ConfigPhysicalLinkStatus is 'up(1)' and the componentIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to component System Management Processor. |
| componentIPv4ConfigTable | 1.3.6.1.4.1.2.3.51.2.22.32.16.1 | not-accessible | Table of all components' network interfaces. | |
| INT componentIPv4ConfigTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.32.16.2 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentIPv4ConfigTable. This value is static (constant) and cannot be set. |
| OCT componentIPv4ConfigTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| INT componentIPv4ConfigVlanId | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.10 | INTEGER | read-write | This is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095. |
| ADR componentIPv6Address | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.6 | InetAddressIPv6 | read-write | The assigned IPv6 address. Note: 'write' is for static ipv6 only. |
| ADR componentIPv6AddressDefaultRoute | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.8 | InetAddressIPv6 | read-write | The default route used for the given address. Note: 'write' is for static ipv6 only. |
| componentIPv6AddressEntry | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1 | not-accessible | The assigned IPv6 address for a given component. NOTE: This MIB object is not applicable to components that do not support IPv6. | |
| INT componentIPv6AddressEntryIndex | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.3 | INTEGER | read-only | The component's address entry index. |
| OCT componentIPv6AddressName | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.4 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| INT componentIPv6AddressPortIndex | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.2 | INTEGER | read-only | The component's physical port number for the given entry. |
| INT componentIPv6AddressPrefixLen | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.7 | INTEGER | read-write | The prefix length for the given address. Note: 'write' is for static ipv6 only. |
| componentIPv6AddressTable | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6 | not-accessible | A table of assigned IPv6 addresses for components. NOTE: This MIB object is not applicable to components that do not support IPv6. | |
| INT componentIPv6AddressTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.7 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentIPv6AddressTable. This value is static (constant) and cannot be set. |
| OCT componentIPv6AddressTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with multiple indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| INT componentIPv6AddressType | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.5 | INTEGER | read-only | The address type. |
| componentIPv6Config | 1.3.6.1.4.1.2.3.51.2.22.32.16.11 | |||
| INT componentIPv6ConfigEnabled | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.4 | INTEGER | read-write | Enables/Disables IPv6 support on the component. |
| componentIPv6ConfigEntry | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1 | not-accessible | IPv6 configuration options for a component. NOTE: This MIB object is not applicable to components that do not support IPv6. | |
| OCT componentIPv6ConfigName | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.3 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| INT componentIPv6ConfigPortIndex | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.2 | INTEGER | read-only | The physical port number of the given entry |
| INT componentIPv6ConfigStatelessEnabled | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.7 | INTEGER | read-write | Enables/Disables IPv6 stateless auto-configuration support on the component. |
| INT componentIPv6ConfigStatic | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.5 | INTEGER | read-write | Enables/Disables IPv6 static configuration support on the component. |
| componentIPv6ConfigTable | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1 | not-accessible | A table of IPv6 configuration options for components. NOTE: This MIB object is not applicable to components that do not support IPv6. | |
| INT componentIPv6ConfigTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.2 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentIPv6ConfigTable. This value is static (constant) and cannot be set. |
| OCT componentIPv6ConfigTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| componentLEDs | 1.3.6.1.4.1.2.3.51.2.22.39 | |||
| OCT componentLEDsDetailsComponentType | 1.3.6.1.4.1.2.3.51.2.22.39.9.1.3 | OCTET STRING | read-only | The type of the component/subcomponent grouping for this LED. |
| componentLEDsDetailsEntry | 1.3.6.1.4.1.2.3.51.2.22.39.9.1 | not-accessible | Component LED info table entry | |
| INT componentLEDsDetailsIndex | 1.3.6.1.4.1.2.3.51.2.22.39.9.1.2 | INTEGER | read-only | Each component may have one or more LEDs and data associated with it, and this index object identifies the particular instance. |
| OCT componentLEDsDetailsLabel | 1.3.6.1.4.1.2.3.51.2.22.39.9.1.4 | OCTET STRING | read-only | The text description of the LED. |
| OCT componentLEDsDetailsLocation | 1.3.6.1.4.1.2.3.51.2.22.39.9.1.6 | OCTET STRING | read-only | The physical location of this LED on the hardware. |
| INT componentLEDsDetailsState | 1.3.6.1.4.1.2.3.51.2.22.39.9.1.5 | INTEGER | read-only | The current state of the LED. |
| componentLEDsDetailsTable | 1.3.6.1.4.1.2.3.51.2.22.39.9 | not-accessible | Table of LED info for each component. | |
| INT componentLEDsDetailsTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.39.10 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentLEDsDetailsTable. This value is static (constant) and cannot be set. |
| OCT componentLEDsDetailsTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.39.9.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| componentLEDsEntry | 1.3.6.1.4.1.2.3.51.2.22.39.1.1 | not-accessible | Component LEDs information entry | |
| componentLEDsTable | 1.3.6.1.4.1.2.3.51.2.22.39.1 | not-accessible | Table of component LED information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more. | |
| INT componentLEDsTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.39.2 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentLEDsTable. This value is static (constant) and cannot be set. |
| OCT componentLevelActivityVpdAction | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.9 | OCTET STRING | read-only | System component level VPD activity log action (added/removed). For consistent results, view as a table and not as individual entries. |
| OCT componentLevelActivityVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.5 | OCTET STRING | read-only | System component level VPD activity log Bay number. For consistent results, view as a table and not as individual entries. |
| OCT componentLevelActivityVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.2 | OCTET STRING | read-only | System component level VPD activity log FRU number. For consistent results, view as a table and not as individual entries. |
| INT componentLevelActivityVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.1 | INTEGER | read-only | System component level VPD activity log index. For consistent results, view as a table and not as individual entries. |
| OCT componentLevelActivityVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.4 | OCTET STRING | read-only | System component level VPD activity log manufacturing ID. For consistent results, view as a table and not as individual entries. |
| OCT componentLevelActivityVpdModuleName | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.12 | OCTET STRING | read-only | The module name which this row is associated with. For consistent results, view as a table and not as individual entries. |
| OCT componentLevelActivityVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.3 | OCTET STRING | read-only | System component level VPD activity log serial number. For consistent results, view as a table and not as individual entries. |
| OCT componentLevelActivityVpdTimestamp | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.10 | OCTET STRING | read-only | System component level VPD activity log timestamp. For consistent results, view as a table and not as individual entries. |
| OCT componentLevelActivityVpdTopologyPath | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.15 | OCTET STRING | read-only | The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. The topology path's numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX, 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| OCT componentMACAddress | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.4 | OCTET STRING | read-only | The MAC address VPD value for this component and index. The value is a null terminated string. For IOMs which are members of a stack, this field is not applicable and should be disregarded. |
| componentMACAddressEntry | 1.3.6.1.4.1.2.3.51.2.22.37.11.1 | not-accessible | Component MAC address table entry | |
| INT componentMACAddressIndex | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.2 | INTEGER | read-only | Each component may have one or more MAC address VPD values associated with it, and this index object identifies the particular instance. |
| OCT componentMACAddressName | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.3 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| componentMACAddressTable | 1.3.6.1.4.1.2.3.51.2.22.37.11 | not-accessible | Table of MAC address VPD information for each component. | |
| INT componentMACAddressTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.37.12 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentMACAddressTable. This value is static (constant) and cannot be set. |
| OCT componentMACAddressTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| componentMonitors | 1.3.6.1.4.1.2.3.51.2.22.37 | |||
| componentNetworkConfiguration | 1.3.6.1.4.1.2.3.51.2.22.32.16 | |||
| componentPower | 1.3.6.1.4.1.2.3.51.2.22.31 | |||
| INT componentPowerAction | 1.3.6.1.4.1.2.3.51.2.22.31.1.1.4 | INTEGER | read-write | Control the power state of a specific component. none: No action, value returned for GET. off: Power-off component. on: Power-on component. softoff: Shutdown OS and power-off component. This operation is not supported on all components. restart: Restart a component. restartSysMgmtProcessor: Restart a component's system management processor. restartNMI: Issue a NMI (Non-Maskable Interrupt) restart to the component. This option is not supported on all components. NOTE: Value returned for the GET command is meaningless for this MIB object. The componentPowerState MIB object should be used to check the power state of the component(s) |
| INT componentPowerDetailsDynamicPowerFavorPerformanceOverPower | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.8 | INTEGER | read-write | When enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and memory utilization implies it would help and the system allows it. Dynamic Power Performance Over Power can be active on the component only after Dynamic Power Saver is enabled. This feature is not available on all components types. Please refer to the component documentation for details. If a component does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power favor performance over power may not complete successfully due to interactions with other component functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. |
| INT componentPowerDetailsDynamicPowerSaver | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.7 | INTEGER | read-write | When enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the component to be controlled based on how busy the CPU is. This feature is not available on all component types. Please refer to the component documentation for details. If a component does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power saver may not complete successfully due to interactions with other component functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable componentPowerDetailsPowerSaverMode if its not already disabled. |
| OCT componentPowerDetailsEffectiveClockRate | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.4 | OCTET STRING | read-only | Component Module Details Table Effective CPU Clock Rate applies to DPM components only. It displays processor's effective clock rate based on sample interval. Note that some components do not effective clock rate. In this case, 'notApplicable' will be displayed. NOTE: The effective clock rate are reported only on a primary slot when a server component spans multiple slots (e.g. double wide or triple wide). For example if the component is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The effective clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4. |
| componentPowerDetailsEntry | 1.3.6.1.4.1.2.3.51.2.22.31.6.1 | not-accessible | Component power Details table entry | |
| OCT componentPowerDetailsMaximumClockRate | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.5 | OCTET STRING | read-only | Component Module Details Table Maximum CPU Clock Rate applies to DPM components only. It displays processor's maximum clock rate based on sample interval. Note that some components do not maximum clock rate. In this case, 'notApplicable' will be displayed. NOTE: The maximum clock rate are reported only on a primary slot when a server components spans multiple slots (e.g. double wide or triple wide). For example if the component is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The maximum clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4. |
| INT componentPowerDetailsMaxPowerConfig | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.3 | INTEGER | read-write | Component Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the component. This function is also known as power capping. Component must be powered on to set this value. If the value of maximum power config is zero, it means the component doesn't support the power capping feature |
| OCT componentPowerDetailsName | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.2 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| OCT componentPowerDetailsPcapGuaranteedMin | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.11 | OCTET STRING | read-only | Component Module Details Table power capping Guaranteed Minimum value in watts. The component must support the advanced power management feature. If the value of Pcap Guaranteed Min is 'notApplicable', it means the component doesn't support the power capping feature. If the value of Pcap GuaranteedMin is 'notAvailable', it means the data could not be obtained. |
| OCT componentPowerDetailsPcapMax | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.12 | OCTET STRING | read-only | Component Module Details Table power capping Maximum value in watts. The component must support the advanced power management feature. If the value is ' Watts, Watts', which means, - if componentPowerDetailsDynamicPowerSaver is enabled, it is - otherwise it is If the value of Pcap Max is 'notApplicable', it means the component doesn't support the power capping feature. If the value of Pcap Min is 'notAvailable', it means the data could not be obtained. |
| OCT componentPowerDetailsPcapMin | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.10 | OCTET STRING | read-only | Component Module Details Table power capping Minimum value in watts. The component must support the advanced power management feature. If the value of Pcap Min is 'notApplicable', it means the component doesn't support the power capping feature. If the value of Pcap Min is 'notAvailable', it means the data could not be obtained. |
| INT componentPowerDetailsPowerControl | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.9 | INTEGER | read-write | This object is used to get or set the power control setting on a component. If dynamic power mgmt is not supported on a component, notApplicable(255) will be returned. This will set the power control setting on all slots of the multiwide component. The same can be used if the component is single wide. |
| INT componentPowerDetailsPowerSaverMode | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.6 | INTEGER | read-write | When enabled, the static low power saver mode allows the component to selectively alter its operating voltage and frequency to reduce power consumption. This feature is not available on all component types. Please refer to the component documentation for details. If a component does not support the static low power saver mode, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the static low power saver mode may not complete successfully due to interactions with other component functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable componentPowerDetailsDynamicPowerSaver if its not already disabled. |
| OCT componentPowerDetailsRuntimeCap | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.14 | OCTET STRING | read-only | Component Module Details Table run-time capabilities list. If the component supports the capability as indicated in the static capability information, the user has the ability to enable or disable that function and this table reflects that configuration. The power management capabilites for the run-time list is as follows: Power Measurement Power Capping Power Saving Dynamic Power Saving Extended Dynamic Power Saving The returned octet string contains 5 pairs of numeric characters separated by blank characters. Each of these pairs will consist of either '00' or '01'. '00' indicates that the capability is currently not available, '01' indicates that the capability is currently available. The 5 pairs represent the current capabilities of the 5 types listed above, in order, for this component in the table. Example response: '01 00 00 00 00' This component has the capability of Power Management only. The current state of the component does not support the remaining 4 capabiites at this time. |
| OCT componentPowerDetailsStaticCap | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.13 | OCTET STRING | read-only | Component Module Details Table static capabilities list. This is a list of five power management capabilities that the component may or may not support. The list of power management capabilities is as follow: Power Measurement Power Capping Power Saving Dynamic Power Saving Extended Dynamic Power Saving The returned octet string contains 5 pairs of numeric characters separated by blank characters. Each of these pairs will consist of either '00' or '01'. '00' indicates that the capability is not there, '01' indicates that the capability is present on the component. The 5 pairs represent the capabilities of the 5 types listed above, in order, for this component in the table. Example response: '01 01 00 00 00' This component has the capability of Power Management and Power Capping, but does not support the last three types. |
| componentPowerDetailsTable | 1.3.6.1.4.1.2.3.51.2.22.31.6 | not-accessible | Table of component power detail information. | |
| INT componentPowerDetailsTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.31.7 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentPowerDetailsTable. This value is static (constant) and cannot be set. |
| OCT componentPowerDetailsTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| INT componentPowerEnableSMSBootMenu | 1.3.6.1.4.1.2.3.51.2.22.31.1.1.5 | INTEGER | read-write | Enables/disables a component restart to the SMS boot menu. Setting this object to 'enable(1)' will cause a reboot of the node to the SMS menu. This option is not supported by all components, and at the time of this MIB definition was only supported on POWER blades. |
| componentPowerEntry | 1.3.6.1.4.1.2.3.51.2.22.31.1.1 | not-accessible | Component power/restart table entry | |
| OCT componentPowerName | 1.3.6.1.4.1.2.3.51.2.22.31.1.1.2 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| componentPowerServiceReset | 1.3.6.1.4.1.2.3.51.2.23.10 | |||
| INT componentPowerState | 1.3.6.1.4.1.2.3.51.2.22.31.1.1.3 | INTEGER | read-only | Indicates the power state of the component specified. If the state cannot be determined, the unknown(255) is returned. |
| componentPowerTable | 1.3.6.1.4.1.2.3.51.2.22.31.1 | not-accessible | Table of component remote power control information. Contains power on/off enablement status for each component. | |
| INT componentPowerTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.31.2 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentPowerTable. This value is static (constant) and cannot be set. |
| OCT componentPowerTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.31.1.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| components | 1.3.6.1.4.1.2.3.51.2.22 | |||
| componentServiceData | 1.3.6.1.4.1.2.3.51.2.23.15 | |||
| OCT componentServiceDataComponentName | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.2 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| OCT componentServiceDataDumpCapabilityMask | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.5 | OCTET STRING | read-only | Indicates whether the component has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to the MM from the component. The values and meanings are as follows: 0000 0000 means this component does not support any at all. 0000 0001 means this component supports 'processor' type and the file remains on the component. 0000 0010 means this component supports 'platform' type and the file remains on the component. 0000 0100 means this component supports 'partition' type and the file remians on the component. 0000 1000 means this component supports 'processor' type and the file can be transferred to the MM. 0001 0000 means this component supports 'platform' type and the file can be transferred to the MM. 0010 0000 means this component supports 'partition' type and the file can be transferred to the MM 0100 0000 means this component supports 'serviceData' type and the file can be transferred to the MM For example, the returned value of 01111000 means this component supports 'processor','platform', 'partition' and 'serviceData' types, and the file can be transferred to the MM |
| INT componentServiceDataDumpInitiate | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.3 | INTEGER | read-write | Initiates a type of dump collection to be initiated for the component and sent to the MM. NOTE: Not all components support this, please check componentServiceDataDumpCapabilityMask OID to see if the action is supported on this component. For switch modules the serviceData(4) is the only available value that can be set. When the dump file is created, the node transfers it to the /tftproot/service directory on the CMM. Only one file can be moved to this directory at a time, so please use the fileManagement MIB information to check if the file has been completed. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT componentServiceDataDumpInProgress | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.6 | INTEGER | read-only | An indicator as to whether a component dump is in progress for the specified component. This object ONLY applies to dumps that can be triggered by the MM and where the dump file is transferred to the MM filesystem upon completion. See the componentServiceDataDumpCapabilityMask object for support levels. The flag that this MIB object represents will be set on when the IPMI command is sent to the component indicating 'init dump' and will be cleared upon receiving the valid dump file from the component or the creation of the text file indicating the problem encountered. If it cannot be determined if the dump is in progress, the unknown(255) value is returned. |
| INT componentServiceDataDumpRetrieve | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.4 | INTEGER | read-write | Retrieve a type of service data file from component to MM. NOTE: This OID only is valid for the last four bit mask designations listed in the componentServiceDataDumpCapabilityMask OID. NOTE: This OID is not used for switch modules. The dump file is transfered to the /tftproot/service directory on the CMM. Only one file can be moved to this directory at a time, so please use the fileManagement MIB information to check if the file has been completed. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| componentServiceDataEntry | 1.3.6.1.4.1.2.3.51.2.23.15.1.1 | not-accessible | Component service data entry | |
| INT componentServiceDataStatus | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.7 | INTEGER | read-only | A status indicator for dump progress. This object ONLY applies to switch modules dumps. |
| OCT componentServiceDataStatusDetails | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.8 | OCTET STRING | read-only | The failure status as a null terminated string. This object ONLY applies to switch modules dumps. |
| componentServiceDataTable | 1.3.6.1.4.1.2.3.51.2.23.15.1 | not-accessible | Table of component service data information. | |
| INT componentServiceDataTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.23.15.2 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentServiceDataTable. This value is static (constant) and cannot be set. |
| OCT componentServiceDataTopologyPath | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| componentServiceReset | 1.3.6.1.4.1.2.3.51.2.22.38 | |||
| INT componentServiceResetCmd | 1.3.6.1.4.1.2.3.51.2.22.38.1.1.4 | INTEGER | read-write | NOTE: Do not perform this service reset operation on a node that is currently in a maintenance mode state. See componentStatusHealthState in componentSystemStatusTable for maintMode(12) value. To reset the auxiliary power on a component, set this object to resetVirtualReseatOperation(1). This will toggle the auxiliary power and simulate a physical removal and insertion. During the operation, auxiliary power is removed from the component and is then restored. For nodes, the power state will remain off and the user will need to manually power on the node. To perform a hard restart on the component, set this object to resetHardRestartOperation(2). This will toggle the reset line to the processor causing it to re-initialize. This object is intended to be write-only. The component will experience a temporary loss of communication and the power state will change. Prior to executing this action, perform any operations needed to protect user data. Reading this object will always return the value of noOperation(0). |
| componentServiceResetEntry | 1.3.6.1.4.1.2.3.51.2.22.38.1.1 | not-accessible | Component module power service reset entry | |
| OCT componentServiceResetName | 1.3.6.1.4.1.2.3.51.2.22.38.1.1.2 | OCTET STRING | read-only | A short text string describing the particular component. For the MM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. |
| INT componentServiceResetStatus | 1.3.6.1.4.1.2.3.51.2.22.38.1.1.3 | INTEGER | read-only | Status of the aux power. A value of auxPowerOff(0) indicates that the componant aux power is off. A value of auxPowerOn(1) indicates that the componant aux power is on. |
| componentServiceResetTable | 1.3.6.1.4.1.2.3.51.2.22.38.1 | not-accessible | A table providing aux power status and the ability to perform a virtual reseat or hard restart of a component. | |
| INT componentServiceResetTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.38.2 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentServiceResetTable. This value is static (constant) and cannot be set. |
| OCT componentServiceResetTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.38.1.1.1 | OCTET STRING | read-only | The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX, 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| INT componentSolBytesReceived | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.11 | INTEGER | read-only | Number of bytes received. |
| INT componentSolBytesSent | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.10 | INTEGER | read-only | Number of bytes sent. |
| INT componentSolCapability | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.6 | INTEGER | read-only | Display whether or not the component supports the Serial-over-LAN (SOL) feature. |
| OCT componentSolConsoleLoginEnd | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.16 | OCTET STRING | read-only | The time that SOL console ends. |
| OCT componentSolConsoleLoginFrom | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.14 | OCTET STRING | read-only | The location information from where the SOL console is logged in. |
| OCT componentSolConsoleLoginStart | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.15 | OCTET STRING | read-only | The time that SOL console starts. |
| OCT componentSolConsoleUserId | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.13 | OCTET STRING | read-only | Sol console user name. |
| OCT componentSolDestinationMAC | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.12 | OCTET STRING | read-only | MAC address of the blade. |
| INT componentSolEnable | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.3 | INTEGER | read-write | Disable or enable the Serial-over-LAN (SOL) on a component. |
| componentSolEntry | 1.3.6.1.4.1.2.3.51.2.22.32.26.1 | not-accessible | Component Serial-over-LAN (SOL) configuration entry. | |
| IP componentSolIpAddr | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.4 | IpAddress | read-only | This is deprecated in favor of componentSolIpAddr. IP address of the component derived from the IP address range for the system management processors on the component. NOTE: The IPv6 address for a component can be view with the componentIPv6AddressTable. |
| ADR componentSolIpAddr6 | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.7 | InetAddressIPv6 | read-only | IPv6 address of the blade. |
| OCT componentSolName | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.2 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| INT componentSolRetryCount | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.9 | INTEGER | read-only | Retry count. |
| INT componentSolRetryInterval | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.8 | INTEGER | read-only | Retry interval time in miliseconds. |
| INT componentSolSessionStatus | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.5 | INTEGER | read-only | Status of a Serial-over-LAN (SOL) session: solSessionNotReady: No SOL session connected to the component. solSessionReady: There is a SOL session to the component. solSessionActive: There is a SOL session to the component and there is a client using the SOL session. |
| componentSolTable | 1.3.6.1.4.1.2.3.51.2.22.32.26 | not-accessible | Component Serial-over-LAN (SOL) configuration table. | |
| INT componentSolTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.32.27 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentSolTable. This value is static (constant) and cannot be set. |
| OCT componentSolTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| INT componentStatusBootCountPowerOnTimeBoots | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.23 | INTEGER | read-write | Blade boot count. This is valid for blade components and otherwise is undefined. Writing this value resets the boot count to zero. |
| INT componentStatusBootCountPowerOnTimeSecs | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.24 | INTEGER | read-write | Blade power on time in seconds. This is valid for blade components and otherwise is undefined. Writing this value resets the power on time to zero. |
| INT componentStatusHealthState | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.4 | INTEGER | read-only | The system health state for the component. Unknown: Component is in an undefined state. Good: Component is operating normally. Warning: One or more outstanding warnings exist for this component. Critical: One or more outstanding critical events for this component. Kernel Mode: Component is in kernel mode. Discovering: The MM is currently in the process of discovering this component. Communications Error: The MM failed to communicate with this component. No Power: No power to the component's domain. Flashing: Flashing in progress. Initialization Failure: Component failed to initialized. Insufficient Power: Not enough power is left in the component's domain to power the component. Power Denied: Power was denied to the component. |
| INT componentStatusInventoryReady | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.22 | INTEGER | read-only | When a component management controller or the MM is reset, the component inventory data is refreshed in the MM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the MM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication for each component regarding the status of this information. Notes: For components that are experiencing a 'communication failure' or 'initialization failure' condition, this object will continue to indicate notReady until the condition is resolved. Therefore, any application that polls this object should also incorporate a timeout period. |
| OCT componentStatusIOCompatibility | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.21 | OCTET STRING | read-only | I/O compatibility status for the component. The possible values and their meanings are as follows: unknown: This indicates a communication error for the component. ok: This is the normal (good) case where the component and the corresponding I/O modules it is internally wired to have no compatibility issues. noIOMs: This means there are no I/O modules in any of the corresponding I/O module bays this component is internally wired to. attention: This indicates that one or more of the corresponding I/O modules are in communication error. mismatch: This indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on the component |
| OCT componentStatusName | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.2 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| INT componentStatusPowerEnable | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.5 | INTEGER | read-only | Power enable state for the component. |
| INT componentStatusPowerState | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.3 | INTEGER | read-only | Indicates the power state of the component specified. |
| OCT componentStatusTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| INT componentStatusWakeOnLanEnable | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.6 | INTEGER | read-only | Wake on LAN enable state for the component. |
| INT componentStatusWidth | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.7 | INTEGER | read-only | The width of the component including any supplement component attached to it |
| componentSystemStatusEntry | 1.3.6.1.4.1.2.3.51.2.22.37.1.1 | not-accessible | Component system status entry | |
| componentSystemStatusTable | 1.3.6.1.4.1.2.3.51.2.22.37.1 | not-accessible | Table of component status information. | |
| INT componentSystemStatusTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.37.2 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentSystemStatusTable. This value is static (constant) and cannot be set. |
| OCT componentTemperaturesComponentName | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.3 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| componentTemperaturesEntry | 1.3.6.1.4.1.2.3.51.2.22.37.21.1 | not-accessible | Component temperatures entry. | |
| INT componentTemperaturesSensorIndex | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.2 | INTEGER | read-only | An index for the temperature Sensors for a given component. |
| OCT componentTemperaturesSensorLabel | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.4 | OCTET STRING | read-only | The label of the sensor as a null terminated string. |
| OCT componentTemperaturesSensorValue | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.5 | OCTET STRING | read-only | The value of the sensor as a null terminated string. |
| OCT componentTemperaturesShutdownThreshold | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.7 | OCTET STRING | read-only | The Shutdown threshold of the sensor as a null terminated string. |
| componentTemperaturesTable | 1.3.6.1.4.1.2.3.51.2.22.37.21 | not-accessible | Table of component temperature sensor information. | |
| INT componentTemperaturesTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.37.22 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentTemperaturesTable. This value is static (constant) and cannot be set. |
| OCT componentTemperaturesTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| OCT componentTemperaturesWarningResetThreshold | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.8 | OCTET STRING | read-only | The Warning Reset threshold of the sensor as a null terminated string. |
| OCT componentTemperaturesWarningThreshold | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.6 | OCTET STRING | read-only | The warning threshold of the sensor as a null terminated string. |
| componentTimeEntry | 1.3.6.1.4.1.2.3.51.2.22.32.20.1 | not-accessible | Component NTP Configuration entry. | |
| OCT componentTimeName | 1.3.6.1.4.1.2.3.51.2.22.32.20.1.2 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| INT componentTimeNTPEnable | 1.3.6.1.4.1.2.3.51.2.22.32.20.1.3 | INTEGER | read-write | This object allows the user to view the status of, and enable or disable, a component's ability to have it's NTP information updated by the CMM. NOTE: If the component either does not exist or does not support this feature, it displays 'notApplicable'. |
| INT componentTimeNTPFrequency | 1.3.6.1.4.1.2.3.51.2.22.32.20.1.4 | INTEGER | read-write | This object allows the user to view or set the synchronization frequency (in minutes) of the NTP information update from the CMM. NOTE: If the component either does not exist or does not support this feature, it displays '0'. |
| componentTimeTable | 1.3.6.1.4.1.2.3.51.2.22.32.20 | not-accessible | Table of Component NTP Configuration. | |
| INT componentTimeTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.32.21 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentTimeTable. This value is static (constant) and cannot be set. |
| OCT componentTimeTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.32.20.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| componentUniqueIDsEntry | 1.3.6.1.4.1.2.3.51.2.22.37.13.1 | not-accessible | Component unique ID table entry | |
| INT componentUniqueIDsIndex | 1.3.6.1.4.1.2.3.51.2.22.37.13.1.2 | INTEGER | read-only | Each component may have one or more unique ID values associated with it, and this index object identifies the particular instance. |
| OCT componentUniqueIDsName | 1.3.6.1.4.1.2.3.51.2.22.37.13.1.3 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| componentUniqueIDsTable | 1.3.6.1.4.1.2.3.51.2.22.37.13 | not-accessible | Table of unique ID information for each component. | |
| INT componentUniqueIDsTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.37.14 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentUniqueIDsTable. This value is static (constant) and cannot be set. |
| OCT componentUniqueIDsTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.37.13.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| INT componentUniqueIDsType | 1.3.6.1.4.1.2.3.51.2.22.37.13.1.4 | INTEGER | read-only | Type of the unique ID in the object, componentUniqueIDsValue. The type is one of the following: World Wide Name (wwn), Global Unique IDs (guid) or Serial Attach SCSI IDs (sas). |
| OCT componentUniqueIDsValue | 1.3.6.1.4.1.2.3.51.2.22.37.13.1.5 | OCTET STRING | read-only | The unique ID value for this component and index. The value is a null terminated string. |
| OCT componentVoltagesComponentName | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.3 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| componentVoltagesEntry | 1.3.6.1.4.1.2.3.51.2.22.37.16.1 | not-accessible | Component voltages entry. | |
| OCT componentVoltagesHighWarningThreshold | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.7 | OCTET STRING | read-only | The high warning threshold of the sensor as a null terminated string. |
| OCT componentVoltagesLowWarningThreshold | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.6 | OCTET STRING | read-only | The low warning threshold of the sensor as a null terminated string. |
| INT componentVoltagesSensorIndex | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.2 | INTEGER | read-only | An index for the critical or warning health events for a given component. |
| OCT componentVoltagesSensorLabel | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.4 | OCTET STRING | read-only | The label of the sensor as a null terminated string. |
| OCT componentVoltagesSensorValue | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.5 | OCTET STRING | read-only | The value of the sensor as a null terminated string. |
| componentVoltagesTable | 1.3.6.1.4.1.2.3.51.2.22.37.16 | not-accessible | Table of component voltage sensor information. | |
| INT componentVoltagesTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.22.37.17 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, componentVoltagesTable. This value is static (constant) and cannot be set. |
| OCT componentVoltagesTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| INT configurationBladeActiveBootMode | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.7 | INTEGER | read-only | Indicates the active copy of the firmware from which the blade is booting. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible. |
| INT configurationBladeAutoPowerOn | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.9 | INTEGER | read-write | Blade auto-power on policy. - restore: blade will be powered on which were previously on. - auto: blade will automatically be powered on when power is applied to the chassis. - manual: blade will be left off until manually powered on by the user. - notApplicable: is a read-only value, this value cannot be set. |
| INT configurationBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.3 | INTEGER | read-only | Indicates whether the server blade specified exists or not. |
| INT configurationBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.2 | INTEGER | read-only | The numeric blade ID. |
| OCT configurationBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.5 | OCTET STRING | read-write | The name of the blade as a null terminated string. |
| INT configurationBladePendingBootMode | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.8 | INTEGER | read-write | Indicates the copy of the firmware from which the blade will boot after the next reboot. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades and the value can not be set. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible. |
| INT configurationBladePowerOnRestartDelay | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.10 | INTEGER | read-write | Restart delay (in seconds) when power is applied to a blade. |
| INT configurationBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.4 | INTEGER | read-only | Indicates the power state of the blade specified. |
| INT configurationIndex | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.1 | INTEGER | read-only | Blade configuration table index. |
| configureSP | 1.3.6.1.4.1.2.3.51.2.4 | |||
| contactInformation | 1.3.6.1.4.1.2.3.51.2.23.4.3 | |||
| OCT contactName | 1.3.6.1.4.1.2.3.51.2.23.4.3.2 | OCTET STRING | read-write | The name of the contact person.1-30 characters. |
| INT critBlade | 1.3.6.1.4.1.2.3.51.2.4.2.1.10 | INTEGER | read-write | Generate an alert for any critical error condition on a blade. |
| INT critChassis | 1.3.6.1.4.1.2.3.51.2.4.2.1.13 | INTEGER | read-write | Generate an alert for any critical error condition on chassis. |
| INT critFan | 1.3.6.1.4.1.2.3.51.2.4.2.1.14 | INTEGER | read-write | Generate an alert for any critical error condition on cooling devices. |
| INT critIO | 1.3.6.1.4.1.2.3.51.2.4.2.1.11 | INTEGER | read-write | Generate an alert for any critical error condition on I/O module. |
| INT critPower | 1.3.6.1.4.1.2.3.51.2.4.2.1.5 | INTEGER | read-write | Generate an alert if any of the system power supplies fail. |
| INT critStorage | 1.3.6.1.4.1.2.3.51.2.4.2.1.12 | INTEGER | read-write | Generate an alert for any critical error condition on a Storage module. |
| INT cryptographicCipher | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.25 | INTEGER | read-write | The cryptographic cipher suite setting. |
| cryptography | 1.3.6.1.4.1.2.3.51.2.4.3.5.10 | |||
| cryptographyCipherComponentEntry | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.30.1 | not-accessible | Cryptography cipher component entry | |
| OCT cryptographyCipherComponentId | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.30.1.2 | OCTET STRING | read-only | A component identifier for an IOM or node in the form: ts:mm. t(type), s(slot number), mm sub-slot number. |
| INT cryptographyCipherComponentIndex | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.30.1.1 | INTEGER | read-only | Cryptography cipher component index. |
| cryptographyCipherComponentTable | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.30 | not-accessible | A table of information listing any IOMs or nodes that are out of compliance with regards to the cipher suite setting and are therefore preventing the CMM from transitioning to the new cipher mode. | |
| INT cryptographyMode | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.15 | INTEGER | read-write | The NIST cryptographic mode setting. A successful setting of this object initiates a reboot of the CMM within a few seconds. |
| cryptographyModeComponentEntry | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.20.1 | not-accessible | Cryptography mode component entry | |
| OCT cryptographyModeComponentId | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.20.1.2 | OCTET STRING | read-only | A component identifier for an IOM or node in the form: ts:mm. t(type), s(slot number), mm sub-slot number. |
| INT cryptographyModeComponentIndex | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.20.1.1 | INTEGER | read-only | Cryptography mode component index. |
| cryptographyModeComponentTable | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.20 | not-accessible | A table of information listing any IOMs or nodes that require a firmware update in order for the CMM to transition to the new mode. | |
| OCT cryptographyModeDetailsDescription | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1.3 | OCTET STRING | read-only | Message containing details for this cryptography entry. |
| cryptographyModeDetailsEntry | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1 | not-accessible | Cryptography mode status entry | |
| INT cryptographyModeDetailsIndex | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1.1 | INTEGER | read-only | Cryptography mode details index. |
| cryptographyModeDetailsTable | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.18 | not-accessible | A table of information indicating any NIST customization details and any reasons that the CMM cannot transition to the desired NIST mode. | |
| INT cryptographyModeDetailsType | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1.2 | INTEGER | read-only | Indication of what type of message is reported for this entry. |
| OCT cryptographySummary | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.5 | OCTET STRING | read-only | The current level and summary description of the cryptographic configuration. |
| OCT currentDirectory | 1.3.6.1.4.1.2.3.51.2.22.11.1.1 | OCTET STRING | read-write | Specifies the directory name for listing the requested files. |
| currentlyLoggedInEntry | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1 | not-accessible | MM users currently logged in entries. | |
| OCT currentlyLoggedInEntryAccMethod | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.3 | OCTET STRING | read-only | Access method for MM users currently logged in. |
| INT currentlyLoggedInEntryIndex | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.1 | INTEGER | read-only | Index for MM users currently logged in. |
| OCT currentlyLoggedInEntryUserId | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.2 | OCTET STRING | read-only | Name for MM users currently logged in. NOTE: 'Default SNMPv1 user' indicates an internal user used by SNMPv1 agent. |
| currentlyLoggedInTable | 1.3.6.1.4.1.2.3.51.2.2.17.1.1 | not-accessible | Table of MM users currently logged in. | |
| customSecuritySettings | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2 | |||
| INT ddnsStatus | 1.3.6.1.4.1.2.3.51.2.4.9.1.10 | INTEGER | read-write | Dynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configured hostnames, addresses or other information stored in DNS. With Dynamic DNS, host computers gain the capability to notify their respective DNS server of the IP address they have received from a DHCP server or through self-configuration. |
| INT defaultAdminPasswordExpired | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.3 | INTEGER | read-write | If enabled, the factory default 'USERID' account password must be changed on next login. The default value is disabled. |
| IP dhcpDHCPServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.6 | IpAddress | read-only | Contains the DHCP server IP address used to acquire the DHCP settings. |
| OCT dhcpDomainName | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.5 | OCTET STRING | read-only | Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. |
| dhcpEthernetInterface | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16 | |||
| IP dhcpGatewayIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.3 | IpAddress | read-only | Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. |
| OCT dhcpHostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.1 | OCTET STRING | read-only | Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. |
| IP dhcpIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.2 | IpAddress | read-only | Contains the IP address for the ethernet interface, assigned by the DHCP server. |
| IP dhcpPrimaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.7 | IpAddress | read-only | Contains the Primary DNS server, assigned by the DHCP server. |
| IP dhcpSecondaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.8 | IpAddress | read-only | Contains the Secondary DNS server, assigned by the DHCP server. |
| IP dhcpSubnetMask | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.4 | IpAddress | read-only | Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server. |
| IP dhcpTertiaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.9 | IpAddress | read-only | Contains the tertiary DNS server, assigned by the DHCP server. |
| dnsConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.2 | |||
| INT dnsEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.1 | INTEGER | read-write | Disable or enable the DNS agent. NOTE: To alter any of the configuration settings for the DNS agent, the following procedure should be used: (1) This object should be set to 'disabled' (2) Make the modifications to other settings (3) This object should be set to 'enabled' Also note that when attempting to enable this agent, it is verified that there is at least one valid DNS server IP address. If this verification fails, an error response will be returned and the DNS agent will be left disabled. |
| INT dnsPriority | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.20 | INTEGER | read-write | Tells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server. |
| IP dnsServerIPAddress1 | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.2 | IpAddress | read-write | Contains the primary DNS server IP address. |
| IP dnsServerIPAddress2 | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.3 | IpAddress | read-write | Contains the secondary DNS server IP address. |
| IP dnsServerIPAddress3 | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.4 | IpAddress | read-write | Contains the tertiary DNS server IP address. |
| ADR dnsServerIPv6Address1 | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.12 | InetAddressIPv6 | read-write | Contains the primary IPv6 DNS server address. |
| ADR dnsServerIPv6Address2 | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.13 | InetAddressIPv6 | read-write | Contains the secondary IPv6 DNS server address. |
| ADR dnsServerIPv6Address3 | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.14 | InetAddressIPv6 | read-write | Contains the tertiary IPv6 DNS server address. |
| OCT domainName | 1.3.6.1.4.1.2.3.51.2.4.9.1.13 | OCTET STRING | read-write | The user assigned DNS domain name. |
| downloadMMServiceData | 1.3.6.1.4.1.2.3.51.2.23.21 | |||
| INT downloadMMServiceDataCancelDownload | 1.3.6.1.4.1.2.3.51.2.23.21.4 | INTEGER | read-write | Set this object to 'cancel(1)' to stop the FFDC file download process. 'cancel(1)' is the only valid value that may be set. The value of this object will be 'cancel(1)' if an user has set this value and an active FFDC download is in progress. After the process has been canceled, this object will automatically be set to 'none(0)'. |
| OCT downloadMMServiceDataFileCreateAndDownload | 1.3.6.1.4.1.2.3.51.2.23.21.1 | OCTET STRING | read-write | Specifying this string initiates the generation of the FFDC (First-Failure Data Capture) data collection (compressed group of files) for the CMM and the download of this file to the specified destination. The destination is a string of chars that specifies the remote location of service data to be saved. Use one of the following protocols: sftp, tftp, ftp, http or https. An example of a qualified location can be: ://[[:password][;fingerprint=]@] [:]/// Note: It is recommended that the saved-data filename have an extension of .tgz to allow support personnel to identify the file. Reading this string will always return 'Not readable' since this string may contain a password. |
| INT downloadMMServiceDataResult | 1.3.6.1.4.1.2.3.51.2.23.21.3 | INTEGER | read-write | An indicator as to whether the FFDC generation and download was successful. The FFDC generation and download is started by setting a destination filename with the object, downloadMMServiceDataFileCreateAndDownload. If the FFDC file generation and download process completes successfully, this object is set to complete(5). If the process encounters an error, this object is set to either: permissionFailed(1), fileGenerationFailed(2) or fileDownloadFailed(3). If the process is canceled by the user, this object will be set to canceled(4). A value of none(0) is the default value. This object may be set to none(0) if the object, downloadMMServiceDataStatus, has a value of ready(0). Setting this object to any value other than none(0) will report an error. |
| INT downloadMMServiceDataStatus | 1.3.6.1.4.1.2.3.51.2.23.21.2 | INTEGER | read-only | An indicator as to whether the FFDC generation and download is in progress. To initiate this process, set the object, downloadMMServiceDataFileCreateAndDownload (see the object's description for details). |
| OCT ehiThermalTrendingAvgEHI | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.5 | OCTET STRING | read-only | Chassis Exhaust Heat Index Thermal Trending Table Average of last 2 Exhaust Heat Index calculations since last reboot. |
| ehiThermalTrendingEntry | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1 | not-accessible | Chassis Exhaust Heat Index Thermal Trending entry. | |
| INT ehiThermalTrendingIndex | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.1 | INTEGER | read-only | Exhaust Heat Index Thermal Trending Table Index. |
| OCT ehiThermalTrendingMaxEHI | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.4 | OCTET STRING | read-only | Chassis Exhaust Heat Index Thermal Trending Table Maximum Exhaust Heat Index since last reboot. |
| OCT ehiThermalTrendingMinEHI | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.3 | OCTET STRING | read-only | Chassis Exhaust Heat Index Thermal Trending Table Minimum Exhaust Heat Index since last reboot. |
| ehiThermalTrendingTable | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70 | not-accessible | Table of Exhaust Heat Index Thermal Trending Information. | |
| OCT ehiThermalTrendingTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.2 | OCTET STRING | read-only | Chassis Exhaust Heat Index Thermal Trending Table Sample Timestamp. |
| OCT emailAddress | 1.3.6.1.4.1.2.3.51.2.23.4.3.4 | OCTET STRING | read-write | The email of the contact person. It must contain '@' and dot '.' in form userid@hostname (130 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters. |
| errorLogs | 1.3.6.1.4.1.2.3.51.2.3 | |||
| eventLog | 1.3.6.1.4.1.2.3.51.2.3.4 | |||
| extEthernetInterface | 1.3.6.1.4.1.2.3.51.2.4.9.1.1 | |||
| OCT extEthernetInterfaceBIA | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.10 | OCTET STRING | read-only | Specifies the burned-in MAC (BIA) address. |
| INT extEthernetInterfaceDataRate | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.5 | INTEGER | read-write | Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G or Auto. |
| INT extEthernetInterfaceDhcpEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.8 | INTEGER | read-write | Disable or enable DHCP on this interface. |
| extEthernetInterfaceDHCPv6Config | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2 | |||
| OCT extEthernetInterfaceDHCPv6DomainName | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.4 | OCTET STRING | read-only | The 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '(Not available)'. |
| INT extEthernetInterfaceDHCPv6Enabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.1 | INTEGER | read-write | The DHCPv6 enabled or disabled state for the ethernet interface. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled is currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled. NOTE: If extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled are currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will not be allowed. |
| ADR extEthernetInterfaceDHCPv6IPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.2 | InetAddressIPv6 | read-only | The IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. |
| ADR extEthernetInterfaceDHCPv6PrimaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.5 | InetAddressIPv6 | read-only | The primary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. |
| ADR extEthernetInterfaceDHCPv6SecondaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.6 | InetAddressIPv6 | read-only | The secondary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. |
| ADR extEthernetInterfaceDHCPv6Server | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.8 | InetAddressIPv6 | read-only | The DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. |
| ADR extEthernetInterfaceDHCPv6TertiaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.7 | InetAddressIPv6 | read-only | The tertiary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. |
| INT extEthernetInterfaceDuplexSetting | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.6 | INTEGER | read-write | Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. |
| IP extEthernetInterfaceFloatingIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.22 | IpAddress | read-write | Contains the floating IP address for the external ethernet interface. |
| IP extEthernetInterfaceGatewayIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.9 | IpAddress | read-write | Contains the IP address of the gateway/router for the ethernet interface. |
| OCT extEthernetInterfaceHostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.3 | OCTET STRING | read-write | Contains the 64 byte null terminated DNS host name for this interface. |
| IP extEthernetInterfaceIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.4 | IpAddress | read-write | Contains the IP address for the ethernet interface. |
| extEthernetInterfaceIPv6 | 1.3.6.1.4.1.2.3.51.2.4.9.1.4 | |||
| extEthernetInterfaceIPv6AutoIPConfig | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3 | |||
| INT extEthernetInterfaceIPv6AutoIPConfigEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.1 | INTEGER | read-write | The IPv6 automatic IP configuration enabled or disabled state for the ethernet interface. NOTE: extEthernetInterfaceIPv6AutoIPConfigEnabled is the logical OR of extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled settings. NOTE: Enabling/Disabling extEthernetInterfaceIPv6AutoIPConfigEnabled will cause both extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled to be enabled/disabled. NOTE: extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6AutoIPConfigEnabled cannot be disabled at the same time. |
| extEthernetInterfaceIPv6Config | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5 | |||
| INT extEthernetInterfaceIPv6Enabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.2 | INTEGER | read-write | The current IPv6 enabled or disabled state of this MM. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this MM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces. |
| ADR extEthernetInterfaceIPv6LinkFloatingAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.5 | InetAddressIPv6 | read-write | The IPv6 floating IP address for the external ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. |
| ADR extEthernetInterfaceIPv6LinkLocalAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1.1 | InetAddressIPv6 | read-only | The IPv6 link local IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. |
| extEthernetInterfaceIPv6LocalAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1 | |||
| extEthernetInterfaceIPv6StatelessAutoConfig | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3 | |||
| INT extEthernetInterfaceIPv6StatelessAutoConfigEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.1 | INTEGER | read-write | The IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface. NOTE: If extEthernetfInterfaceDHCPv6Enabled is currently disabled, Disabling extEthernetInterfaceIPv6StatelessAutoConfigEnabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled. |
| ADR extEthernetInterfaceIPv6StaticIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.2 | InetAddressIPv6 | read-write | The IPv6 static IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. |
| INT extEthernetInterfaceIPv6StaticIPAddressPrefixLen | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.3 | INTEGER | read-write | The IPv6 static IP address prefix length for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value 0. |
| extEthernetInterfaceIPv6StaticIPConfig | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2 | |||
| INT extEthernetInterfaceIPv6StaticIPConfigEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.1 | INTEGER | read-write | The IPv6 static IP address enabled or disabled state for the ethernet interface. |
| ADR extEthernetInterfaceIPv6StaticIPDefaultRoute | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.4 | InetAddressIPv6 | read-write | The IPv6 static IP address default route for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. |
| OCT extEthernetInterfaceIPv6Type | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.1 | OCTET STRING | read-only | The type of interface. |
| OCT extEthernetInterfaceLAA | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.7 | OCTET STRING | read-write | Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup MM, it is not recommended. |
| INT extEthernetInterfaceMTU | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.13 | INTEGER | read-write | Contains the Maximum Transmission Unit(MTU) for the ethernet interface |
| ADR extEthernetInterfaceStatelessAutoConfigAddresses | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.2 | InetAddressIPv6 | read-only | The stateless Auto-Configuration IPv6 address. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. |
| extEthernetInterfaceStatelessAutoConfigAddressesEntry | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1 | not-accessible | Stateless Auto-Config address entries | |
| INT extEthernetInterfaceStatelessAutoConfigAddressesIndex | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.1 | INTEGER | read-only | Index for stateless Auto-Config addresses. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. |
| INT extEthernetInterfaceStatelessAutoConfigAddressesPrefixLen | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.3 | INTEGER | read-only | The stateless Auto-Configration address prefix length. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. |
| extEthernetInterfaceStatelessAutoConfigAddressesTable | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2 | not-accessible | Table of stateless Auto-Config addresses entries | |
| IP extEthernetInterfaceSubnetMask | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.14 | IpAddress | read-write | Contains the subnet mask for the ethernet interface |
| OCT extEthernetInterfaceType | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.1 | OCTET STRING | read-only | The type of interface. |
| fanPack | 1.3.6.1.4.1.2.3.51.2.2.6 | |||
| OCT fanPackAverageSpeed | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.5 | OCTET STRING | read-only | The average speed of all fans in the fan pack expressed in percent(%) of maximum RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. |
| OCT fanPackAverageSpeedRPM | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.6 | OCTET STRING | read-only | The average speed of all fans in the fan pack expressed in RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. |
| INT fanPackControllerState | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.7 | INTEGER | read-only | The health state for the controller for the fan pack. |
| fanPackEntry | 1.3.6.1.4.1.2.3.51.2.2.6.1.1 | not-accessible | Fan Pack entry | |
| INT fanPackExists | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.2 | INTEGER | read-only | Indicates whether the fan pack specified exists or not. |
| INT fanPackFanCount | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.4 | INTEGER | read-only | The number of fans in the fan pack. |
| INT fanPackIndex | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.1 | INTEGER | read-only | Fan Pack sequence index. |
| fanPackLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.6 | |||
| fanPackLEDsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1 | not-accessible | Fan Pack LEDs information entry | |
| fanPackLEDsTable | 1.3.6.1.4.1.2.3.51.2.2.8.6.1 | not-accessible | Table of fan pack LEDs information. This table is deprecated because the LEDs for the power modules' fans are no longer on the fan packs, the LEDs are on the power modules. See the MIB tables, componentLEDsTable and componentLEDsDetailsTable, for the power modules' LEDs. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | |
| INT fanPackState | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.3 | INTEGER | read-only | The health state for the fan pack. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Attention, Critical CLI - OK, Non-critical, Critical |
| fanPackTable | 1.3.6.1.4.1.2.3.51.2.2.6.1 | not-accessible | Table of fan pack information. Contains the information for each fan pack. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | |
| INT faultLED | 1.3.6.1.4.1.2.3.51.2.2.8.1.1 | INTEGER | read-only | Indicates whether the front panel system error LED is on or off. |
| fileDetailsEntry | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1 | not-accessible | File details entry. | |
| fileDetailsTable | 1.3.6.1.4.1.2.3.51.2.22.11.1.2 | not-accessible | A table of all the files in the specified directory. | |
| INT fileIndex | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.1 | INTEGER | read-only | File sequence index. |
| OCT fileLastUpdate | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.3 | OCTET STRING | read-only | Date of the latest file update. |
| fileManagement | 1.3.6.1.4.1.2.3.51.2.22.11 | |||
| OCT fileManagementCmd | 1.3.6.1.4.1.2.3.51.2.22.11.3 | OCTET STRING | read-write | This field will execute the selected operations on the files. The following operation is supported: DEL name - delete a file Examples: - to delete the file named switch.config in tftproot directory set the value to 'DEL tftproot/switch.config' NOTE: Value returned for the GET command is meaningless for this MIB object. |
| OCT fileName | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.2 | OCTET STRING | read-only | File name. |
| OCT fileSize | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.4 | OCTET STRING | read-only | File size in bytes. |
| OCT fileSystemSpaceAvailable | 1.3.6.1.4.1.2.3.51.2.22.11.6 | OCTET STRING | read-only | This field displays the available space of the MM file system. |
| fileTopology | 1.3.6.1.4.1.2.3.51.2.22.11.1 | |||
| INT firmwareActiveImage | 1.3.6.1.4.1.2.3.51.2.22.9.8 | INTEGER | read-write | If the module can upload more than one image, an active image number must be specified. Please refer to the firmwareInformation section. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT firmwareImageNumber | 1.3.6.1.4.1.2.3.51.2.22.9.7 | INTEGER | read-write | If the module can upload more than one image, an image number must be specified after setting the firmware target. Please refer to the firmwareInformation section. |
| firmwareInformation | 1.3.6.1.4.1.2.3.51.2.22.8 | |||
| firmwareUpdate | 1.3.6.1.4.1.2.3.51.2.22.9 | |||
| OCT firmwareUpdateFileName | 1.3.6.1.4.1.2.3.51.2.22.9.3 | OCTET STRING | read-write | File name of the firmware file. |
| OCT firmwareUpdateServer | 1.3.6.1.4.1.2.3.51.2.22.9.9 | OCTET STRING | read-write | Contains the fully qualified remote location of the firmware packet file. Use firmwareUpdateFileName to specify the filename. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the packet file resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The MM currently supports the following protocols: TFTP, FTP, HTTP and HTTPS. The complete format of a fully qualified remote location is: ://@/ An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the packet file is /tmp. and firmwareUpdateFileName is set to: cmefs.uxp Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be: :///. Note: When updating certain switches via SFTP, only an RSA fingerprint is supported. Please see your switch documentation for more information. |
| INT firmwareUpdateStart | 1.3.6.1.4.1.2.3.51.2.22.9.4 | INTEGER | read-write | Start updating the firmware of the specified target module. Using execute or execute-with-reboot will cause the SNMP client to wait for the firmware update to complete. Using execute-nowait or execute-with-reboot-nowait will not cause the SNMP client to wait for the update to complete. Instead it will flash the firmware in the background. Note 1: If the execute-with-reboot or execute-with-reboot-nowait option is selected, the target will reset after a successful flash. This option is only valid if the firmwareUpdateTarget object is set to managementModule. Note 2: If flashing from a remote file, then both firmwareUpdateServer and firmwareUpdateFileName must be set. Otherwise if flashing via the legacy method using a tftp server, then both firmwareUpdateTftpServer and firmwareUpdateFileName must be set. Note 3: Depending on the target, it might take up to several minutes for the flash update to complete. Do not reset the target until the control has been returned. At this point, the results will be displayed. Note 4: Use firmwareUpdateStatus to confirm the status of the last firmware update initiated by SNMP method. The Management Module must be restarted for the new firmware to take affect. Note 5: If data encryption is currently enabled on this MM, and you update the MM firmware to a level which does not support data encryption, you will lose all your configuration settings as a result. Note 6: Since some I/O Module types use the MM TFTP server for firmware file transfer during the firmware update process, the tftpEnable MIB object must be set to enable prior to updating the firmware for these modules. Note 7: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this MM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| OCT firmwareUpdateStatus | 1.3.6.1.4.1.2.3.51.2.22.9.5 | OCTET STRING | read-only | Get the status of the last firmware update which was initiated through SNMP method. |
| INT firmwareUpdateTarget | 1.3.6.1.4.1.2.3.51.2.22.9.1 | INTEGER | read-write | Target module whose firmware will be updated. NOTE: Some switch modules do not allow firmware update. When firmware update is attempted on those switch modules, the agent will report an error. |
| OCT firmwareUpdateTftpServer | 1.3.6.1.4.1.2.3.51.2.22.9.2 | OCTET STRING | read-write | If flashing via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). NOTE: IPv6 numeric addresses must be enclosed with brackets (e.g. [fe80::5652:ff:fe50:53b6]). |
| frontPanelLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.1 | |||
| INT ftpDataPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.14 | INTEGER | read-write | FTP Data port number. Default value is 20. Port change will take effect immediately. |
| INT ftpEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.17 | INTEGER | read-write | Disable/Enable FTP. |
| INT ftpPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.13 | INTEGER | read-write | FTP port number. Default value is 21. Port change will take effect immediately. |
| INT ftpTimeout | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.23 | INTEGER | read-write | The amount of time before FTP times out. Default is 300 seconds. Value of zero is no timeout. Max value is any positive 4 byte value. |
| fuelGauge | 1.3.6.1.4.1.2.3.51.2.2.10 | |||
| OCT fuelGaugeAllocatedPower | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.8 | OCTET STRING | read-only | This field displays the power that has been reserved in each power domain. |
| fuelGaugeEntry | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1 | not-accessible | Fuel Gauge entry | |
| INT fuelGaugeIndex | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.1 | INTEGER | read-only | Fuel Gauge Table Index. |
| fuelGaugeInformation | 1.3.6.1.4.1.2.3.51.2.2.10.1 | |||
| INT fuelGaugePowerDomainNumber | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.2 | INTEGER | read-only | Fuel Gauge Table Power Domain Number. |
| OCT fuelGaugePowerInUsed | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.10 | OCTET STRING | read-only | This field displays the total power being used in each power domain. |
| INT fuelGaugePowerManagementPolicySetting | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.6 | INTEGER | read-only | Power Management Policy Setting for each power domain. A new powerPolicyTable has been added which provides more detailed information regarding a domains power policy information. This table also has the capability to SET the power policy for a given domain. Power Module Redundancy Intended for a single power source into the chassis where each Power Module is on its own dedicated circuit. Maximum power is limited to one less than the number of Power Modules when more than one Power Module is present. One Power Module can fail without affecting compute node operation. Multiple Power Module failures can cause the chassis to power off. Note that some compute nodes may not be allowed to power on if doing so would exceed the policy power limit. Power Module Redundancy with Compute Nodes Throttling Allowed Very similar to Power Module Redundancy. This policy allows for a higher power limit; however, capable compute nodes may be allowed to throttle down if one Power Module fails. Basic Power Management Maximum power limit is higher than other policies and is limited only by the nameplate power of all the Power Modules combined. This is the least conservative approach, since it does not provide any protection for power source or Power Module failure. If any single power supply fails, compute node and/or chassis operation may be affected. Power Source Redundancy Intended for dual power sources into the chassis. Maximum power is limited to the capacity of half the number of installed power modules. This is the most conservative approach and is recommended when all power modules are installed. When the chassis is correctly wired with dual power sources, one power source can fail without affecting compute node server operation. Note that some compute nodes may not be allowed to power on if doing so would exceed the policy power limit. Power Source Redundancy with Compute Node Throttling Allowed Very similar to the Power Source Redundancy. This policy allows for a higher power limit, however capable compute nodes may be allowed to throttle down if one power source fails. |
| OCT fuelGaugePowerModules | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.4 | OCTET STRING | read-only | Fuel Gauge Table Power Module capacity in Watts in the power domain. |
| OCT fuelGaugeRemainingPower | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.9 | OCTET STRING | read-only | This field displays the remaining power available in each domain. Remaining Power = Total Power minus Power In Use |
| OCT fuelGaugeStatus | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.3 | OCTET STRING | read-only | Fuel Gauge Table Status for the power domain. The response will start out with a numeric value (0 = unknown, 1 = good, 2 = warning, and 3: bad), followed by a text message. |
| fuelGaugeTable | 1.3.6.1.4.1.2.3.51.2.2.10.1.1 | not-accessible | Table of Fuel Gauge information. | |
| OCT fuelGaugeTotalPower | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.7 | OCTET STRING | read-only | This field displays the total available power for each power domain based on installed power modules and the current Power Management Policy Setting. |
| generalRemoteCfg | 1.3.6.1.4.1.2.3.51.2.4.1.1 | |||
| INT generateTestAlert | 1.3.6.1.4.1.2.3.51.2.4.1.3.30 | INTEGER | read-write | Generate a Test Alert. This will send a test alert to all configured and enabled remote alert recipients. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| ENT groupEntryStatus | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.9 | EntryStatus | read-write | This object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table groupEntryStatus = createRequest 2. Set groupId as required. Then the entry will be valid. valid(1) - Indicates that the group represented by this entry is available for use. createRequest(2) - A new entry will be created in this table for the specified group and the new entry will transition to the underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry. |
| OCT groupId | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.2 | OCTET STRING | read-write | Group ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones. |
| groupIdsEntry | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1 | not-accessible | Group ID entries. | |
| groupIdsTable | 1.3.6.1.4.1.2.3.51.2.4.1.7.1 | not-accessible | Table of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles. | |
| INT groupIndex | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.1 | INTEGER | read-only | Index for Group IDs entry. |
| groupProfiles | 1.3.6.1.4.1.2.3.51.2.4.1.7 | |||
| INT groupRBSBlade1 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.4 | INTEGER | read-write | Group has access to the blade in slot 1. |
| INT groupRBSBlade10 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.13 | INTEGER | read-write | Group has access to the blade in slot 10. |
| INT groupRBSBlade11 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.14 | INTEGER | read-write | Group has access to the blade in slot 11. |
| INT groupRBSBlade12 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.15 | INTEGER | read-write | Group has access to the blade in slot 12. |
| INT groupRBSBlade13 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.16 | INTEGER | read-write | Group has access to the blade in slot 13. |
| INT groupRBSBlade14 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.17 | INTEGER | read-write | Group has access to the blade in slot 14. |
| INT groupRBSBlade2 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.5 | INTEGER | read-write | Group has access to the blade in slot 2. |
| INT groupRBSBlade3 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.6 | INTEGER | read-write | Group has access to the blade in slot 3. |
| INT groupRBSBlade4 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.7 | INTEGER | read-write | Group has access to the blade in slot 4. |
| INT groupRBSBlade5 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.8 | INTEGER | read-write | Group has access to the blade in slot 5. |
| INT groupRBSBlade6 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.9 | INTEGER | read-write | Group has access to the blade in slot 6. |
| INT groupRBSBlade7 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.10 | INTEGER | read-write | Group has access to the blade in slot 7. |
| INT groupRBSBlade8 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.11 | INTEGER | read-write | Group has access to the blade in slot 8. |
| INT groupRBSBlade9 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.12 | INTEGER | read-write | Group has access to the blade in slot 9. |
| INT groupRBSBladeAdministration | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.13 | INTEGER | read-write | Group can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs. |
| INT groupRBSBladeConfiguration | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.12 | INTEGER | read-write | Group can modify and save any blade configuration parameter. |
| INT groupRBSBladeOperator | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.10 | INTEGER | read-write | Group has ability to browse status and properties of blades. |
| INT groupRBSBladeRemotePresence | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.11 | INTEGER | read-write | Group has ability to access the blade remote console The ability to issue the CLI console command to start an SOL session to a blade will also require this authority. |
| INT groupRBSChassis | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.3 | INTEGER | read-write | Group has access to the MM and chassis functions. |
| INT groupRBSChassisAccountManagement | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.6 | INTEGER | read-write | Group can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority. |
| INT groupRBSChassisAdministration | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.9 | INTEGER | read-write | Group has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the group also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file. |
| INT groupRBSChassisConfiguration | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.8 | INTEGER | read-write | Group can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the group also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file. |
| INT groupRBSChassisLogManagement | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.7 | INTEGER | read-write | Group has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file. |
| INT groupRBSChassisOperator | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.5 | INTEGER | read-write | Group has ability to browse status and properties of chassis components (MM, chassis fans, midplane, power modules). Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access. |
| INT groupRBSOperator | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.4 | INTEGER | read-write | Group has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.). |
| groupRBSroleEntry | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1 | not-accessible | Group Role entries. | |
| OCT groupRBSroleId | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.2 | OCTET STRING | read-only | Group ID |
| INT groupRBSroleIndex | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.1 | INTEGER | read-only | Index for Group Role entry. |
| groupRBSroleTable | 1.3.6.1.4.1.2.3.51.2.4.1.7.2 | not-accessible | Table of Group Role profiles. | |
| groupRBSscopeEntry | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1 | not-accessible | Group Scope entries. | |
| OCT groupRBSscopeId | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.2 | OCTET STRING | read-only | Group ID |
| INT groupRBSscopeIndex | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.1 | INTEGER | read-only | Index for Group Scope Entry. |
| groupRBSscopeTable | 1.3.6.1.4.1.2.3.51.2.4.1.7.3 | not-accessible | Table of Group Scope profiles. | |
| INT groupRBSSupervisor | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.3 | INTEGER | read-write | Group has no restrictions. |
| INT groupRBSSwitch1 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.18 | INTEGER | read-write | Group has access to I/O module 1. |
| INT groupRBSSwitch10 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.27 | INTEGER | read-write | Group has access to I/O module 10. |
| INT groupRBSSwitch2 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.19 | INTEGER | read-write | Group has access to I/O module 2. |
| INT groupRBSSwitch3 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.20 | INTEGER | read-write | Group has access to I/O module 3. |
| INT groupRBSSwitch4 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.21 | INTEGER | read-write | Group has access to I/O module 4. |
| INT groupRBSSwitch5 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.22 | INTEGER | read-write | Group has access to I/O module 5. |
| INT groupRBSSwitch6 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.23 | INTEGER | read-write | Group has access to I/O module 6. |
| INT groupRBSSwitch7 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.24 | INTEGER | read-write | Group has access to I/O module 7. |
| INT groupRBSSwitch8 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.25 | INTEGER | read-write | Group has access to I/O module 8. |
| INT groupRBSSwitch9 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.26 | INTEGER | read-write | Group has access to I/O module 9. |
| INT groupRBSSwitchModuleAdministration | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.16 | INTEGER | read-write | Group can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet session to an I/O Module, or to restore factory defaults on an I/O Module. |
| INT groupRBSSwitchModuleConfiguration | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.15 | INTEGER | read-write | Group can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet session to an I/O Module, or to restore factory defaults on an I/O Module. |
| INT groupRBSSwitchModuleOperator | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.14 | INTEGER | read-write | Group has ability to browse status and properties of I/O Modules, and to ping I/O Modules. |
| OCT groupRole | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.3 | OCTET STRING | read-only | Group Role. It indicates if the group has supervisor, operator, or custom access. |
| OCT hostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.11 | OCTET STRING | read-write | Contains the DNS host name for this system. This object provides the exact same function as extEthernetInterfaceHostName |
| INT hotAirRecircMonitoring | 1.3.6.1.4.1.2.3.51.2.2.1.9.3 | INTEGER | read-write | If this is enabled, the management module will monitor for Hot Air Recirculation by detecting non-uniform air temperature(s) that may be entering the front of the chassis. This could be due to either localized hot or cold air reaching at least one of the node's or chassis temperature sensors and it exceeding the acceptable range. When enabled, this monitor will generate an event and be transmitted to any configured remote alert recipient. |
| hotAirRecircStatusEntry | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1 | not-accessible | Hot air recirculation status entry | |
| INT hotAirRecircStatusExceeded | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.7 | INTEGER | read-only | Indicates whether this component has exceeded the threshold of the acceptable temperature being monitored for hot air recirculation. |
| INT hotAirRecircStatusIndex | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.3 | INTEGER | read-only | Each component may have one or more sensor associated with it, this index object identifies the particular instance. |
| OCT hotAirRecircStatusName | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.4 | OCTET STRING | read-only | The name of the component as a null terminated string |
| OCT hotAirRecircStatusSensorLabel | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.5 | OCTET STRING | read-only | The text label of the sensor as a null terminated string |
| OCT hotAirRecircStatusSensorReading | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.6 | OCTET STRING | read-only | Ambient temperature reading for this component in degrees centigrade(C). The string is formatted as 'dd.dd Centigrade'. |
| hotAirRecircStatusTable | 1.3.6.1.4.1.2.3.51.2.2.1.9.7 | not-accessible | Table of hot air recirculation status information. | |
| OCT hotAirRecircStatusTopologyPath | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.2 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| INT hotAirRecircTempDeltaThresh | 1.3.6.1.4.1.2.3.51.2.2.1.9.5 | INTEGER | read-write | This object is used to read or change the temperature delta threshold for Hot Air Recirculation detection. Values are enforced to be in the inclusive range between 5.00C and 9.00C and are specified as hundreths of a degree. For example, a value of 659 would equate to a threshold of 6.59 degrees C. |
| INT httpPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.2 | INTEGER | read-write | HTTP port number. Default value is 80. Once changed, the URL's have to include :port at the end. |
| httpProxyConfig | 1.3.6.1.4.1.2.3.51.2.23.4.4 | |||
| INT httpProxyEnable | 1.3.6.1.4.1.2.3.51.2.23.4.4.1 | INTEGER | read-write | Disable/Enable of the HTTP Proxy. Select Enable to use the proxy for call home connections from the MM to IBM. HTTP Proxy is used by the MM when it is not connected to the internet directly. |
| OCT httpProxyLocation | 1.3.6.1.4.1.2.3.51.2.23.4.4.2 | OCTET STRING | read-write | Fully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters. |
| OCT httpProxyPassword | 1.3.6.1.4.1.2.3.51.2.23.4.4.5 | OCTET STRING | read-write | Password of the HTTP Proxy. A maximum of 15 characters string without spaces. |
| INT httpProxyPort | 1.3.6.1.4.1.2.3.51.2.23.4.4.3 | INTEGER | read-write | The port number of the HTTP Proxy. An integer value from 1 to 65535. |
| OCT httpProxyUserName | 1.3.6.1.4.1.2.3.51.2.23.4.4.4 | OCTET STRING | read-write | User Name of the HTTP Proxy. A maximum of 30 characters string without spaces. |
| INT httpsPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.3 | INTEGER | read-write | SSL port number. Default value is 443. Once changed, the URL's have to include :port at the end. |
| ibm | 1.3.6.1.4.1.2 | |||
| ibmAgents | 1.3.6.1.4.1.2.3 | |||
| OCT ibmSupportCenter | 1.3.6.1.4.1.2.3.51.2.23.4.2.1 | OCTET STRING | read-write | The country code for the IBM Support Center. 2 character ISO country code. |
| INT identifyLED | 1.3.6.1.4.1.2.3.51.2.2.8.1.4 | INTEGER | read-write | Indicates whether the front panel identity LED is on or off. |
| INT inactivityAlertDisablePeriod | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.9 | INTEGER | read-write | The period of time in days before generating an alert and disabling a dormant account. This value applies to all login accounts, excluding the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be greater than the inactivityAlertPeriod. |
| INT inactivityAlertPeriod | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.8 | INTEGER | read-write | The period of time in days before generating an alert for a dormant account. This value applies to all login accounts, including the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be less than the inactivityAlertDisablePeriod. |
| internalTemp | 1.3.6.1.4.1.2.3.51.2.2.1.1 | |||
| inventoryManagementActivityVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.22.1 | not-accessible | System component hardware VPD activity log entry. For consistent results, view as a table and not as individual entries. | |
| inventoryManagementActivityVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.22 | not-accessible | Table of system component hardware VPD activity log. For consistent results, view as a table and not as individual entries. | |
| INT ldapAuthCfg | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.22 | INTEGER | read-write | If ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LDAP Authentication Only mode is currently supported only in an Active Directory environment. |
| INT ldapBindingMethod | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.10 | INTEGER | read-write | On initial binds to the LDAP server during user authentication, there are two options: Client authentication: Bind attempt is made with client DN and password specified by this configuration parameter. If the bind is successful, we proceed as above. User Principal Name (UPN): Bind attempt is made directly with the credentials used during the login process. If this succeeds, the user is deemed to have passed the user authentication phase. Note that for Active Directory servers, the userid can have the form someuser@somedomain or simply someuser. |
| OCT ldapClientAuthenticationDN | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.11 | OCTET STRING | read-write | The initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client based option requires a client DN and password as parameters to the bind request. These parameters are configured here. Note that the password can be left blank. |
| OCT ldapClientAuthenticationPassword | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.12 | OCTET STRING | read-write | The client authentication password |
| ldapClientCfg | 1.3.6.1.4.1.2.3.51.2.4.9.3.6 | |||
| OCT ldapDomainName | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.24 | OCTET STRING | read-write | A NULL terminated 255 byte string that contains the LDAP Domain Name. |
| OCT ldapForestName | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.23 | OCTET STRING | read-write | LDAP Forest Name. Note: LDAP Forest Name is only for Active Directory environment. |
| OCT ldapGroupFilter | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.9 | OCTET STRING | read-write | This filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Otherwise, group authentication will be performed against the filter. The filter can be a specific group name (e.g. RSAWest), a wildcard (*) which matches everything, or a wildcard with a prefix (e.g. RSA*). The default filter is RSA*. After user authentication, group authentication will take place, whereby an attempt will be made to match the group or groups (that the user belongs to) to the group filter defined here. If there is no match, the user will not pass authentication and will be blocked. If there is a match, the login permissions for the user will be retrieved from the matched group(s), unless the user already has login permissions assigned directly from the user record retrieved from the LDAP server. |
| OCT ldapGroupSearchAttribute | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.14 | OCTET STRING | read-write | When the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is required to do group authentication. In order to retrieve this list, the search filter sent to the server must specify the attribute name associated with groups. This field specifies this attribute name. If this field is left blank, the attribute name in the filter will default to memberOf. |
| OCT ldapLoginPermissionAttribute | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.15 | OCTET STRING | read-write | When a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissions, the search filter sent to the server must specify the attribute name associated with login permissions. This field specifies this attribute name. |
| INT ldapRBSModelCfg | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.20 | INTEGER | read-write | There are two mechanisms to authenticate and authorize users on the MM when using an LDAP-enabled server. The first mechanism (oldPermissionString), also known as version 1, uses bitstrings to associate permissions to users and groups. Version1 supports Active Directory, Novell eDirectory, and OPenLDAP based servers. The second mechanism (newRBSModel), also known as version 2, uses a new Role-Based-Security (RBS) model. This mechanism is only available for Active Directory servers, and requires the use of a snap-in that runs on any windows platform. This snap-in tool allows you to configure roles on an Active Directory server of your choice, and to associate users/groups and MMs to those roles. A role identifies the permissions given to users and groups associated with that role, and also identifies the targets (e.g. MM) to which this role is attached. The use of bitstrings in version 2 disappears, making the configuration much more manageable and user-friendly. Note that if you are not using Active Directory, then you should not enable version 2. Also note that before enabling version 2, you should already have your roles configured on your Active Directory server. The old version 1 bitstring model cannot be automatically converted to the new version 2 model. This is why you must configure your users and groups before enabling version 2. Once enabled, the change takes effect immediately. The default value for this field is oldPermissionString. |
| OCT ldapRootDN | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.7 | OCTET STRING | read-write | A NULL terminated 255 byte string that contains the distinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com. |
| OCT ldapServer1NameOrIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.1 | OCTET STRING | read-write | A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). |
| INT ldapServer1PortNumber | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.2 | INTEGER | read-write | LDAP server port number. |
| OCT ldapServer2NameOrIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.3 | OCTET STRING | read-write | A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). |
| INT ldapServer2PortNumber | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.4 | INTEGER | read-write | LDAP server port number. |
| OCT ldapServer3NameOrIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.5 | OCTET STRING | read-write | A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). |
| INT ldapServer3PortNumber | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.6 | INTEGER | read-write | LDAP server port number. |
| OCT ldapServer4NameOrIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.25 | OCTET STRING | read-write | A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). |
| INT ldapServer4PortNumber | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.26 | INTEGER | read-write | LDAP server port number. |
| OCT ldapTargetName | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.21 | OCTET STRING | read-write | When administrator chooses Enhanced Role Based Security authentication model, he can associate one MM with one managed target object in Snap-in (one tool to configure LDAP users permission) via one target name. The MM target name can be looked as alias of MM, administrator can change it according to his configuration requirements. This is a string of up to 63 characters (plus the null character) |
| OCT ldapUIDsearchAttribute | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.13 | OCTET STRING | read-write | When the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aimed at retrieving specific information about the user, including the user's DN, login permissions, and group ownerships. In order to retrieve this information, the search request must specify the attribute name used to represent userids on that server. Specifically, this name is used as a search filter against the login id entered by the user. This attribute name is configured here. If this field is left blank, a default of uid is used during user authentication. For example, on Active Directory servers, the attribute name used for userids is often sAMAccoutName. When the binding method selected is UPN or Strict UPN, this field defaults automatically to userPrincipalName during user authentication if the userid entered has the form userid@somedomain. |
| INT ldapUseDNSOrPreConfiguredServers | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.16 | INTEGER | read-write | The MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used for authentication can be discovered dynamically or manually pre-configured. If the usePreConfiguredLDAPServers option is selected, up to 4 LDAP servers can be configured. Simply enter the server's IP address or hostname (assuming DNS is enabled). The port number for each server is optional. If left blank, the default value of 389 is used for non-secured LDAP connections. For secured connections, the default is 636. At least one server must be configured. If the useDNSToFindLDAPServers is selected, the domain name need to be provided. For LDAP Authentication Only mode, additional information such as the forest name also need to be provided. |
| OCT ledBladeBayNumber | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.2 | OCTET STRING | read-only | The bay number of the main server blade that the LED is grouped into. |
| INT ledBladeCheckLog | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.8 | INTEGER | read-write | Indicates whether the blade check log information LED is on or off. For Write access, the LED can be turned off only. |
| OCT ledBladeComponentType | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.3 | OCTET STRING | read-only | Type of the component/subcomponent grouping for this LED. |
| INT ledBladeExists | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.3 | INTEGER | read-only | Indicates whether the blade specified exists or not. |
| INT ledBladeFault | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.7 | INTEGER | read-only | Indicates whether the blade fault LED is on or off. |
| INT ledBladeHealthState | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.5 | INTEGER | read-only | The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The MM is currently in the process of discovering this blade. Communications Error: The MM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. |
| INT ledBladeId | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.2 | INTEGER | read-only | The numeric blade ID. |
| INT ledBladeIdentify | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.11 | INTEGER | read-write | Indicates whether the blade identify LED is on, off, or blinking. |
| INT ledBladeIndex | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.1 | INTEGER | read-only | Blade LED table index. |
| OCT ledBladeLabel | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.4 | OCTET STRING | read-only | Text label for a LED. |
| OCT ledBladeLocation | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.6 | OCTET STRING | read-only | Location of this LED. |
| OCT ledBladeName | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.6 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| INT ledBladePowerState | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.4 | INTEGER | read-only | Indicates the power state of the blade specified. |
| INT ledBladeState | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.5 | INTEGER | read-only | Text description which denotes color or on/off/blink state for a LED. |
| INT ledChassisFanError | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.4 | INTEGER | read-only | Indicates whether the chassis fan error LED is on, off, or not available. |
| INT ledChassisFanExists | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.3 | INTEGER | read-only | Indicates whether the chassis fan specified exists or not. |
| INT ledChassisFanId | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.2 | INTEGER | read-only | The numeric chassis fan ID. |
| INT ledChassisFanIndex | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.1 | INTEGER | read-only | Chassis fan LEDs table index. |
| INT ledComponentCheckLog | 1.3.6.1.4.1.2.3.51.2.22.39.1.1.4 | INTEGER | read-write | Indicates whether the component check log information LED is on or off. For Write access, the LED can be turned off only. |
| INT ledComponentFault | 1.3.6.1.4.1.2.3.51.2.22.39.1.1.3 | INTEGER | read-only | Indicates whether the component fault LED is on or off. |
| INT ledComponentIdentity | 1.3.6.1.4.1.2.3.51.2.22.39.1.1.5 | INTEGER | read-write | Indicates whether the component identify LED is on, off, or blinking. |
| OCT ledComponentName | 1.3.6.1.4.1.2.3.51.2.22.39.1.1.2 | OCTET STRING | read-only | The name of the component as a null terminated string. |
| OCT ledComponentTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.39.1.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| INT ledFanPackError | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.4 | INTEGER | read-only | Indicates whether the fan pack error LED is on or off. |
| INT ledFanPackExists | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.3 | INTEGER | read-only | Indicates whether the fan pack specified exists or not. |
| INT ledFanPackId | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.2 | INTEGER | read-only | The numeric fan pack ID. |
| INT ledFanPackIndex | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.1 | INTEGER | read-only | Fan Pack LEDs table index. |
| INT ledIndex | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.1 | INTEGER | read-only | The LED index number. |
| leds | 1.3.6.1.4.1.2.3.51.2.2.8 | |||
| INT ledSMIndex | 1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.1 | INTEGER | read-only | Switch module LEDs table index. |
| OCT ledSMLabel | 1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.3 | OCTET STRING | read-only | The name associated with the LED. |
| OCT ledSMLocation | 1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.5 | OCTET STRING | read-only | The physical location where the LED can be found on the Switch. |
| INT ledSMSlot | 1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.2 | INTEGER | read-only | The bay number of the switch. |
| INT ledSMState | 1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.4 | INTEGER | read-write | NOTE: This table entry is read-write ONLY when Label = 'Enclosure Identity'. All other Label values have read-only access. |
| INT licenseKeyComponentIndex | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.1 | INTEGER | read-only | License key component table index. |
| OCT licenseKeyDescription | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.3 | OCTET STRING | read-only | The description for a license key. |
| INT licenseKeyIndex | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.2 | INTEGER | read-only | The license key index for the chassis component. |
| licenseKeyInfo | 1.3.6.1.4.1.2.3.51.2.2.30 | |||
| licenseKeyInfoEntry | 1.3.6.1.4.1.2.3.51.2.2.30.1.1 | not-accessible | License key information entry. | |
| licenseKeyInfoTable | 1.3.6.1.4.1.2.3.51.2.2.30.1 | not-accessible | Table of license key information. | |
| OCT licenseKeyLicenseID | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.5 | OCTET STRING | read-only | The unique identifier for this license key. |
| OCT licenseKeyOtherInfo | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.6 | OCTET STRING | read-only | Any other information related to this license key. |
| INT licenseKeyStatus | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.7 | INTEGER | read-only | The current status of this license key. |
| OCT licenseKeyTimestamp | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.4 | OCTET STRING | read-only | The date and time of this license key. |
| INT lockoutPeriod | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.10 | INTEGER | read-write | The period of time in minutes that a user is locked out after the maximum number of login failures was reached. The minimum value is is 1 minute and the maximum value is 2880 minutes. The default value is 2 minutes for the Legacy security level and 60 minutes for the High security level. A value of 0 disables this option. |
| INT logicalUplinkCheckDelay | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.5 | INTEGER | read-write | Delay, in minutes(1-2880), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM. |
| INT logicalUplinkCheckDelayInSecs | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.7 | INTEGER | read-write | Delay, in seconds(60-172800), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM. |
| INT logicalUplinkCheckEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.4 | INTEGER | read-write | Disable or enable network uplink checking for logical detection. logicalUplinkDestination must be set to a non-zero IP Address before enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. |
| IP logicalUplinkDestination | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.3 | IpAddress | read-write | Destination IP for MM to check its logical link. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. |
| INT logicalUplinkFailoverPolicy | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.9 | INTEGER | read-write | Determines when to failover if both an IPv4 and IPv6 destination have been configured. If set to 'either' the system will failover if either of the destination's link check fails. If set to 'both' then the IPv4 and IPv6 link checks must fail before a failover will happen. NOTE: This MIB object is only applicable to systems with a standby MM. |
| ADR logicalUplinkIPv6Destination | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.8 | InetAddressIPv6 | read-write | Destination IP for MM to check its logical link using IPv6. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. |
| managementModule | 1.3.6.1.4.1.2.3.51.2.22.5 | |||
| INT maxLoginFailures | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.11 | INTEGER | read-write | The maximum number of login failures before a user account is locked. A value of 0 disables this option. The default value is 5. |
| INT maxSessionsPerLDAPUser | 1.3.6.1.4.1.2.3.51.2.4.1.1.9 | INTEGER | read-write | The maximum number of simultaneous active sessions allowed for each LDAP user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20. |
| INT minimumDiffCharsPassword | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.6 | INTEGER | read-write | The required minimum number of characters in the new password different from the previous password. The default value is 2. A SET of this object is ignored until the complexPasswordRules option is enabled and the minimumPasswordReuseCycle is not none(0) |
| INT minimumPasswordReuseCycle | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.4 | INTEGER | read-write | The number of unique passwords a user must choose before reusing a password. The default value is none. |
| mmBistAndChassisStatus | 1.3.6.1.4.1.2.3.51.2.2.5.2 | |||
| IP mmExtIpAddress | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.3 | IpAddress | read-only | Management module external IP address. NOTE: The IPv6 addresses assigned to the MM may be viewed with the extEthernetInterfaceIPv6 objects |
| mmFirmwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.3 | |||
| mmHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.2 | |||
| OCT mmHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.2 | OCTET STRING | read-only | Management module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. |
| OCT mmHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.13 | OCTET STRING | read-only | Management module hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries. |
| mmHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1 | not-accessible | Management module hardware VPD entry. For consistent results, view as a table and not as individual entries. | |
| OCT mmHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.4 | OCTET STRING | read-only | Management module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. |
| OCT mmHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.9 | OCTET STRING | read-only | Management module hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. |
| INT mmHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.5 | INTEGER | read-only | Management module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. |
| OCT mmHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.14 | OCTET STRING | read-only | Management module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. |
| INT mmHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.1 | INTEGER | read-only | Management module hardware VPD index. For consistent results, view as a table and not as individual entries. |
| OCT mmHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.3 | OCTET STRING | read-only | Management module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. |
| OCT mmHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.10 | OCTET STRING | read-only | Management module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. |
| OCT mmHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.7 | OCTET STRING | read-only | Management module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. |
| OCT mmHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.8 | OCTET STRING | read-only | Management module hardware VPD Part number. For consistent results, view as a table and not as individual entries. |
| OCT mmHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.11 | OCTET STRING | read-only | Management module hardware VPD product ID. For consistent results, view as a table and not as individual entries. |
| OCT mmHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.12 | OCTET STRING | read-only | Management module hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries. |
| mmHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.2.1 | not-accessible | Table of the management module hardware components. For consistent results, view as a table and not as individual entries. | |
| OCT mmHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.6 | OCTET STRING | read-only | Management module hardware VPD UUID. For consistent results, view as a table and not as individual entries. |
| INT mmHealthState | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.5 | INTEGER | read-only | The health state for the management module. 0 = unknown, 1 = good, 2 = warning, 3 = bad. |
| OCT mmMainApplVpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.6 | OCTET STRING | read-only | Firmware VPD build date. |
| OCT mmMainApplVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.3 | OCTET STRING | read-only | Firmware VPD build identification. |
| mmMainApplVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1 | not-accessible | MM Firmware VPD entry. | |
| OCT mmMainApplVpdFilename | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.5 | OCTET STRING | read-only | Firmware VPD file name. |
| INT mmMainApplVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.1 | INTEGER | read-only | Firmware VPD index. |
| OCT mmMainApplVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.2 | OCTET STRING | read-only | Firmware VPD name description. 'MM firmware' indicates the running firmware of the MM. 'MM firmware (pending restart)' indicates the flashed firmware of the MM which will become active after the next restart. |
| OCT mmMainApplVpdRevisonNumber | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.4 | OCTET STRING | read-only | Firmware VPD revision number. |
| mmMainApplVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.3.1 | not-accessible | Table of MM Firmware VPD. | |
| INT mmPresent | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.2 | INTEGER | read-only | Management module current status. |
| INT mmPrimary | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.4 | INTEGER | read-only | Indicates if this Management module is a primary or not. NOTE: If there is no standby MM, this value defaults to primary. |
| mmSshClientAuth | 1.3.6.1.4.1.2.3.51.2.4.1.6 | |||
| OCT mmSshClientAuthPubKeyAcceptFrom | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.6 | OCTET STRING | read-write | This is a filter that describes the set of SSH client IP addresses and host names that can establish SSH connections to the MM authenticated by the public key represented by this entry of the table. The filter is a comma-separated list of IP addresses and/or hostnames. A question mark may be used to match any single character. An asterisk may be used to match multiple characters. An exclamation point may preceed an IP address or hostname to deny acccess from that IP address or hostname. The format of the Accept From specification is: from=PATTERN-LIST PATTERN-LIST is the filter, which must be enclosed in double quotation marks. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed. |
| INT mmSshClientAuthPubKeyAction | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.8 | INTEGER | read-write | import(1) starts the TFTP file transfer of an SSH client authentication public key from the TFTP server to the MM. The import operation is only accepted if the associated RemoteAccessIdsEntry row is configured and the current value of mmSshClientAuthPubKeyEntryStatus is underCreation(3) or valid(1), if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1), it will replace the key with a new key, If the import is successful the value of mmSshClientAuthPubKeyRowStatus changes to valid(1). export(2) starts the TFTP file transfer of an SSH client authentication public key from the MM to the TFTP server. The export operation is only accepted if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1). NOTE: Users should compare the fingerprint value mmSshClientAuthPubKeyFingerprint to the fingerprint of client authentication key files imported or exported using the TFTP file transfer protocol to guard against possible file corruption. Value returned for the GET command is meaningless for this MIB object. |
| OCT mmSshClientAuthPubKeyComment | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.7 | OCTET STRING | read-write | This is a descriptive string that the administrator may use to help identify the public key represented by this entry. It serves no function in the operation of the SSH server. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed. |
| mmSshClientAuthPubKeyEntry | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1 | not-accessible | A information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessIdEntryIndex. The secondary table index allows selection of the Nth public key for that remoteAccessIdEntryIndex. | |
| ENT mmSshClientAuthPubKeyEntryStatus | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.9 | EntryStatus | read-write | This object manages the creation and deletion of this entry. The steps recommended to install and to activate a new client authorization public key are: 1. Set values for mmSshClientAuthPubKeyTftpServer, mmSshClientAuthPubKeyFileName, mmSshClientAuthPubKeyFileFormat 2. Create a new entry in this table mmSshClientAuthPubKeyEntryStatus = createRequest 3. Import a new key mmSshClientAuthPubKeyAction = import This entry will be valid after mmSshClientAuthPubKeyAction is successfully imported. 4. Set mmSshClientAuthPubKeyAcceptFrom and mmSshClientAuthPubKeyComment as required. valid(1) - Indicates that the public key pair represented by this entry is available for use by the Secure Shell Server for client authentication. createRequest(2) - A new entry will be created in this table for the specified host key pair and the new entry will transition to the underCreation(3) state. The operation is only accepted if the associated RemoteAccessIdsEntry row defining a local user account is configured. underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry and any client authentication public key that may be associated with it. Note: only one row may be created at one time. |
| INT mmSshClientAuthPubKeyFileFormat | 1.3.6.1.4.1.2.3.51.2.4.1.6.5 | INTEGER | read-write | File format of SSH client authentication public key files imported from or exported to the TFTP file server. |
| OCT mmSshClientAuthPubKeyFileName | 1.3.6.1.4.1.2.3.51.2.4.1.6.4 | OCTET STRING | read-write | File name on the TFTP server of an SSH client authentication public key. |
| OCT mmSshClientAuthPubKeyFingerprint | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.5 | OCTET STRING | read-only | The RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the managed entity. This is the fingerprint of the operational host key pair. If the key pair represented by this entry is not operational then sixteen null octets must be returned. |
| INT mmSshClientAuthPubKeyIndex | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.2 | INTEGER | read-only | The secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 to N where N is the number of keys associated with a particular remote access Id. An addition always causes the value of N to increase by one, effectively adding an entry after the existing keys for that remote access Id. If an entry is deleted from the table by setting mmSshClientAuthPubKeyEntryStatus = invalid, the key associated with that entry is deleted. If the deleted key was not the last key for a remote access Id (mmSshClientAuthPubKeyIndex is not the 'last' or Nth entry), the subsequent entries are renumbered after the deletion. A deletion always causes the value of N to decrease by one. The underlying SSH server implementation searches the keys in order from 1 to N when attempting public key authentication. NOTE:A maximum of 4 public keys can be installed for one remote access Id. |
| INT mmSshClientAuthPubKeySize | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.4 | INTEGER | read-only | The size of the SSH public key represented by this entry. |
| mmSshClientAuthPubKeyTable | 1.3.6.1.4.1.2.3.51.2.4.1.6.1 | not-accessible | A table that contains client authentication public key information. | |
| OCT mmSshClientAuthPubKeyTftpServer | 1.3.6.1.4.1.2.3.51.2.4.1.6.3 | OCTET STRING | read-write | IP address or host name of the TFTP server where an SSH client authentication public key is to be installed from or exported to. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). |
| INT mmSshClientAuthPubKeyType | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.3 | INTEGER | read-only | The type of the SSH public key represented by this entry. |
| INT mmSshClientAuthPubKeyUnused | 1.3.6.1.4.1.2.3.51.2.4.1.6.2 | INTEGER | read-only | The number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key is added to the configuration. |
| OCT mmSshClientAuthPubKeyUserId | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.10 | OCTET STRING | read-only | The userid for the key entry. |
| INT mmSshClientAuthRemoteAccessIdIndex | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.1 | INTEGER | read-only | The primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable. |
| mmSshServerConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27 | |||
| mmSshServerHostKeyEntry | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1 | not-accessible | A list of information about a particular public/private host key pair. | |
| OCT mmSshServerHostKeyFingerprint | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.4 | OCTET STRING | read-only | The RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the MM. |
| INT mmSshServerHostKeyGenerate | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.2 | INTEGER | read-write | Initiate the new Host Keys generation process for the MM SSH Server. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| OCT mmSshServerHostKeyGenerateProgress | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.3 | OCTET STRING | read-only | Indicate the progress of the key generation process. |
| INT mmSshServerHostKeyIndex | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.1 | INTEGER | read-only | The index of the public/private host key pair. |
| INT mmSshServerHostKeySize | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.3 | INTEGER | read-only | The size of the public/private host key pair. NOTE: The MM supports only the bits2048 value. |
| mmSshServerHostKeyTable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1 | not-accessible | A table that contains per public/private host key pair information. | |
| INT mmSshServerHostKeyType | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.2 | INTEGER | read-only | The type of the public/private host key pair. |
| mmStatusEntry | 1.3.6.1.4.1.2.3.51.2.22.5.1.1 | not-accessible | Management module status entry. | |
| INT mmStatusIndex | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.1 | INTEGER | read-only | Management module status index. |
| mmStatusTable | 1.3.6.1.4.1.2.3.51.2.22.5.1 | not-accessible | Table of the management module status. | |
| mmUsers | 1.3.6.1.4.1.2.3.51.2.2.17.1 | |||
| moduleInformation | 1.3.6.1.4.1.2.3.51.2.2.10.4 | |||
| INT monitorLogStateEvents | 1.3.6.1.4.1.2.3.51.2.3.4.4 | INTEGER | read-write | If disabled, it means the info LED will not turn on when the log gets full and no alerts will be sent out. If enabled, the LED will turn on when the log gets full and alerts will be sent out. |
| monitors | 1.3.6.1.4.1.2.3.51.2.2 | |||
| monitorTemp | 1.3.6.1.4.1.2.3.51.2.2.1.9 | |||
| netfinitySupportProcessorAgent | 1.3.6.1.4.1.2.3.51 | |||
| INT networkChangeNotification | 1.3.6.1.4.1.2.3.51.2.4.2.3.12 | INTEGER | read-write | Generate an alert if the MM has restarted and the internal network has initialized successfully, or if an IP address change via a source other than the management module. |
| networkConfiguration | 1.3.6.1.4.1.2.3.51.2.4.9 | |||
| networkInterfaces | 1.3.6.1.4.1.2.3.51.2.4.9.1 | |||
| nodeConnectivityEntry | 1.3.6.1.4.1.2.3.51.2.22.37.31.1 | not-accessible | Connectivity information for nodes. | |
| INT nodeConnectivityIndex | 1.3.6.1.4.1.2.3.51.2.22.37.31.1.1 | INTEGER | read-only | Node Connectivity table index. |
| OCT nodeConnectivityName | 1.3.6.1.4.1.2.3.51.2.22.37.31.1.2 | OCTET STRING | read-only | The name of the node as a null terminated string. |
| INT nodeConnectivityStatus | 1.3.6.1.4.1.2.3.51.2.22.37.31.1.3 | INTEGER | read-only | Indicates the communication status of the node. |
| nodeConnectivityTable | 1.3.6.1.4.1.2.3.51.2.22.37.31 | not-accessible | Table of node connectivity information. This table provides information related to the node communication status. | |
| OCT nodeFirmwareAnalysisBuildId | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.4 | OCTET STRING | read-only | The firmware build id. |
| OCT nodeFirmwareAnalysisDeviceName | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.8 | OCTET STRING | read-only | The node device name. |
| nodeFirmwareAnalysisEntry | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1 | not-accessible | Node firmware analysis information. | |
| OCT nodeFirmwareAnalysisFirmwareType | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.3 | OCTET STRING | read-only | The firmware type. |
| INT nodeFirmwareAnalysisIndex | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.1 | INTEGER | read-only | The index for the node firmware levels. |
| OCT nodeFirmwareAnalysisMachineTypeModel | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.2 | OCTET STRING | read-only | The machine type or model of node firmware. |
| OCT nodeFirmwareAnalysisReleaseDate | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.5 | OCTET STRING | read-only | The firmware release date. |
| OCT nodeFirmwareAnalysisRevisionLevel | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.6 | OCTET STRING | read-only | The firmware revision level. |
| nodeFirmwareAnalysisTable | 1.3.6.1.4.1.2.3.51.2.2.23.2.7 | not-accessible | Table of firmware levels of installed nodes. This information is grouped by Machine Type/Model and includes two or more nodes with the same Type/Model. This information is intended to be used in determining which components firmware may need upgrade. | |
| OCT nodeFirmwareAnalysisTopology | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.7 | OCTET STRING | read-only | The node topology. |
| INT ntpAuthEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.7 | INTEGER | read-write | Enables/Disables NTP v3 authentication |
| OCT ntpAuthEntry | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.6 | OCTET STRING | read-write | The NTP v3 authentication entry to be used for time sync with a secure NTP server. The format of an authentication entry is . must be an integer between 1 and 65535. must be M. is the actual value of the authentication key as configured on the NTP server. The GET command returns back data in the format: It does not return the actual key. |
| ntpConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.8 | |||
| INT ntpEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.1 | INTEGER | read-write | Disable/Enable the NTP client. The client will update the MM system clock at the frequency specified. |
| OCT ntpIpAddressHostname | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.2 | OCTET STRING | read-write | NTP server's IP address or hostname if DNS is enabled and configured. |
| OCT ntpLastUpdate | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.4 | OCTET STRING | read-only | The date and time that the NTP server last updated the system clock. |
| INT ntpUpdateClock | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.5 | INTEGER | read-write | Update the MM system clock with the specified NTP server. A valid NTP server must be configured first. |
| INT ntpUpdateFrequency | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.3 | INTEGER | read-write | The frequency in minutes that the NTP service runs. The value range is 0 to 45000. If the NTP update frequency is set to 0, the MM clock can only be synchronized with the NTP server manually. |
| passiveAirFilter | 1.3.6.1.4.1.2.3.51.2.2.22.1 | |||
| INT passiveAirFilterMonthFreq | 1.3.6.1.4.1.2.3.51.2.2.22.1.2 | INTEGER | read-write | The chassis environment. 1 month indicates high dust, 3 months indicates moderate dust and, 6 months indicates low dust. |
| OCT passiveAirFilterReplaceDate | 1.3.6.1.4.1.2.3.51.2.2.22.1.3 | OCTET STRING | read-only | The scheduled replacement date of the air filter. |
| INT passiveAirFilterStatus | 1.3.6.1.4.1.2.3.51.2.2.22.1.1 | INTEGER | read-write | Disable/Enable/Reset the passive air filter. When enabled, sending an enable or reset will reset the replace date. |
| INT passwordChangeInterval | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.12 | INTEGER | read-write | A minimum period of time that user is not able to change their own password. The range of acceptable values will be from 0 to 1440 (or 60 days). A value of 0 disables this option. If the password expiration period is set, it must be greater than the minimum password change interval. |
| INT passwordExpirationPeriod | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.2 | INTEGER | read-write | The number of days before login passwords expire. The minimum value is 1 day and the maximum value is 365 days. The default value is 90 days. A value of 0 disables this option. |
| OCT pd1BayNumber | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2 | OCTET STRING | read-only | Power Domain 1 Table Bay Number. The following Bay Number IDs are used: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), fanPackBay5(7), fanPackBay6(8), chassisfanBay1(9), chassisfanBay2(10), chassisfanBay3(11), chassisfanBay4(12), chassisfanBay5(13), chassisfanBay6(14), chassisfanBay7(15), chassisfanBay8(16), chassisfanBay9(17), chassisfanBay10(18), managementModuleBay1(19), managementModuleBay2(20), ioModuleBay1(21), ioModuleBay2(22), ioModuleBay3(23), ioModuleBay4(24), serverBladeBay1(25), serverBladeBay2(26), serverBladeBay3(27), serverBladeBay4(28), serverBladeBay5(29), serverBladeBay6(30), serverBladeBay7(31), serverBladeBay8(32), serverBladeBay9(33), serverBladeBay10(34), serverBladeBay11(35), serverBladeBay12(36), serverBladeBay13(37), serverBladeBay14(38), notApplicable(39) |
| INT pd1BladePrimarySlot | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.3 | INTEGER | read-only | Power Domain 1 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. |
| INT pd1Index | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.1 | INTEGER | read-only | Power Domain 1 Table Index. |
| OCT pd1ModuleAllocatedPowerCurrent | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.7 | OCTET STRING | read-only | Power Domain 1 Table Allocated Power Current indicates the current power allocation for the module in Watts. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the current power allocation for the module is equally divided among the slots. |
| OCT pd1ModuleAllocatedPowerMax | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8 | OCTET STRING | read-only | Power Domain 1 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the module will consume in the domain when it is fully populated with memory chips, expansion cards, etc. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the maximum power allocation for the module is equally divided among the slots. |
| OCT pd1ModuleAllocatedPowerMin | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.9 | OCTET STRING | read-only | Power Domain 1 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of the component in the domain based on its maximum throttle limit. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the minimum power allocation for the module is equally divided among the slots. |
| OCT pd1ModuleCPUDutyCycles | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.10 | OCTET STRING | read-only | Power Domain 1 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that some blades do not report the CPU duty cycles. In this case, 'notApplicable' will be displayed. NOTE: The CPU duty cycles are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The CPU duty cycles are reported on slot 3 while 'notApplicable' is displayed for slot 4. |
| INT pd1ModuleMeasuredOrStatic | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.13 | INTEGER | read-only | Power Domain 1 Table Module Measured Or Static. |
| OCT pd1ModuleName | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.5 | OCTET STRING | read-only | Power Domain 1 Table Module Name. |
| INT pd1ModulePowerCapabilities | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.12 | INTEGER | read-only | Power Domain 1 Table Module Power Capabilities. staticPowerManagement: the module with the static worst case power values. fixedPowermanagement: the module with the static power values but ability to throttle. dynamicPowerManagement: the module with power meter capability, measurement enabled, but capping disabled. dynamicPowerMeasurement1: the module with power meter capability, measurement enabled, phase 1 only dynamicPowerMeasurement2: the module with power meter capability, measurement enabled, phase 2 or higher dynamicPowerMeasurementWithPowerCapping: the module with power meter capability, both measurement and capping enabled, phase 2 or higher |
| INT pd1ModuleState | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.6 | INTEGER | read-only | Power Domain 1 Table Module State. |
| INT pd1ModuleStatus | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.4 | INTEGER | read-only | Power Domain 1 Table Module Throttle Status. |
| INT pd1ModuleThrottle | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.11 | INTEGER | read-only | Power Domain 1 Table Module Throttle indicates whether the server blade may be allowed to throttle or not. |
| INT pd1PowerTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.1 | INTEGER | read-write | Specify time period for power domain 1 power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Power Domain. |
| OCT pd1PowerTrendingSampleAve | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.3 | OCTET STRING | read-only | Power Domain 1 Power Trending Table Average Power. |
| pd1PowerTrendingSampleEntry | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1 | not-accessible | Power Domain 1 Power Trending Sample entry. | |
| INT pd1PowerTrendingSampleIndex | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.1 | INTEGER | read-only | Power Domain 1 Power Trending Sample Table Index. |
| pd1PowerTrendingSampleTable | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10 | not-accessible | Table of Power Domain 1 Power Trending Information. | |
| OCT pd1PowerTrendingSampleTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.2 | OCTET STRING | read-only | Power Domain 1 Power Trending Sample Table Timestamp. |
| OCT pd1TopologyPath | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.14 | OCTET STRING | read-only | The topology path for the component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| OCT phoneNumber | 1.3.6.1.4.1.2.3.51.2.23.4.3.3 | OCTET STRING | read-write | The phone of the contact person. 5-30 characters. |
| OCT phoneNumberExt | 1.3.6.1.4.1.2.3.51.2.23.4.3.9 | OCTET STRING | read-write | The phone number extension of the contact person. 1-30 characters. |
| INT physicalUplinkCheckDelayInSecs | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.6 | INTEGER | read-write | Delay, in seconds(10-172800), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM. |
| pmControllerVPDEntry | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1 | not-accessible | Power Module controller firmware VPD table entry | |
| INT pmControllerVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.3 | INTEGER | read-only | Indicates whether the Power Module specified exists or not. |
| INT pmControllerVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.2 | INTEGER | read-only | The numeric Power Module ID. |
| INT pmControllerVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.1 | INTEGER | read-only | Power Module controller firmware VPD table index. |
| OCT pmControllerVpdRevision | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.7 | OCTET STRING | read-only | The revision of the Power Module controller firmware. |
| pmControllerVPDTable | 1.3.6.1.4.1.2.3.51.2.2.21.14.1 | not-accessible | Table of Power Module controller firmware vital product data (VPD) information. | |
| pmFirmwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.14 | |||
| pmHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.8 | |||
| OCT pmHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.2 | OCTET STRING | read-only | Power module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. |
| OCT pmHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.15 | OCTET STRING | read-only | Power module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. |
| pmHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1 | not-accessible | Power module hardware VPD entry. For consistent results, view as a table and not as individual entries. | |
| OCT pmHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.4 | OCTET STRING | read-only | Power module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. |
| OCT pmHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.11 | OCTET STRING | read-only | Power module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. |
| INT pmHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.5 | INTEGER | read-only | Power module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. |
| OCT pmHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.16 | OCTET STRING | read-only | Power module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. |
| INT pmHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.1 | INTEGER | read-only | Power module hardware VPD index. For consistent results, view as a table and not as individual entries. |
| OCT pmHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.3 | OCTET STRING | read-only | Power module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. |
| OCT pmHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.12 | OCTET STRING | read-only | Power module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. |
| OCT pmHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.9 | OCTET STRING | read-only | Power module hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries. |
| OCT pmHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.10 | OCTET STRING | read-only | Power module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. |
| OCT pmHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.13 | OCTET STRING | read-only | Power module hardware VPD product ID. For consistent results, view as a table and not as individual entries. |
| OCT pmHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.14 | OCTET STRING | read-only | Power module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. |
| pmHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.8.1 | not-accessible | Table of the power module hardware components. For consistent results, view as a table and not as individual entries. | |
| OCT pmHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.8 | OCTET STRING | read-only | Power module hardware VPD UUID. For consistent results, view as a table and not as individual entries. |
| INT policyControlBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.3 | INTEGER | read-only | Indicates whether the server blade specified exists or not. |
| INT policyControlBladeHealthState | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.5 | INTEGER | read-only | The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The MM is currently in the process of discovering this blade. Communications Error: The MM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. |
| INT policyControlBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.2 | INTEGER | read-only | The numeric blade ID. |
| OCT policyControlBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.6 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| INT policyControlBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.4 | INTEGER | read-only | The power state for blade. 0 = off, 1 = on, 3 = standby, 4 = hibernate, 255 = unknown. |
| INT policyControlIndex | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.1 | INTEGER | read-only | Blade power policy control index. |
| INT policyLocalPowerControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.7 | INTEGER | read-write | Blade local power policy control enablement status. |
| INT policyWakeOnLanControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.10 | INTEGER | read-write | Blade Wake On LAN enablement status. If WOL is not supported by the blade, it displays 'notApplicable' and WOL can not be enabled or disabled. |
| INT portBaud | 1.3.6.1.4.1.2.3.51.2.4.1.2.1 | INTEGER | read-write | Baud rate for the serial port. |
| INT portParity | 1.3.6.1.4.1.2.3.51.2.4.1.2.2 | INTEGER | read-write | Parity setting for the serial port. |
| INT portStopBits | 1.3.6.1.4.1.2.3.51.2.4.1.2.3 | INTEGER | read-write | Number of stop bits for the serial port. |
| OCT postalCode | 1.3.6.1.4.1.2.3.51.2.23.4.3.8 | OCTET STRING | read-write | The postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid. |
| powerDomain1 | 1.3.6.1.4.1.2.3.51.2.2.10.2 | |||
| powerDomain1Entry | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1 | not-accessible | Fuel Gauge entry | |
| powerDomain1PowerTrending | 1.3.6.1.4.1.2.3.51.2.2.10.2.3 | |||
| powerDomain1Table | 1.3.6.1.4.1.2.3.51.2.2.10.2.1 | not-accessible | Table of Power Domain 1. | |
| INT powerManagementPolicy | 1.3.6.1.4.1.2.3.51.2.22.1.7.2.1 | INTEGER | read-write | Power Module Redundancy Intended for a single power source into the chassis where each Power Module is on its own dedicated circuit. Maximum power is limited to one less than the number of Power Modules when more than one Power Module is present. One Power Module can fail without affecting compute node operation. Multiple Power Module failures can cause the chassis to power off. Note that some compute nodes may not be allowed to power on if doing so would exceed the policy power limit. Power Module Redundancy with Compute Nodes Throttling Allowed Very similar to Power Module Redundancy. This policy allows for a higher power limit; however, capable compute nodes may be allowed to throttle down if one Power Module fails. Basic Power Management Maximum power limit is higher than other policies and is limited only by the nameplate power of all the Power Modules combined. This is the least conservative approach, since it does not provide any protection for power source or Power Module failure. If any single power supply fails, compute node and/or chassis operation may be affected. Power Source Redundancy Intended for dual power sources into the chassis. Maximum power is limited to the capacity of half the number of installed power modules. This is the most conservative approach and is recommended when all power modules are installed. When the chassis is correctly wired with dual power sources, one power source can fail without affecting compute node server operation. Note that some compute nodes may not be allowed to power on if doing so would exceed the policy power limit. Power Source Redundancy with Compute Node Throttling Allowed Very similar to the Power Source Redundancy. This policy allows for a higher power limit, however capable compute nodes may be allowed to throttle down if one power source fails. Please see the powerPolicyTable for more information regarding this setting. |
| OCT powerModuleDescription | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.9 | OCTET STRING | read-only | The description for this power module. |
| OCT powerModuleDetails | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.4 | OCTET STRING | read-only | The details for this power module. |
| INT powerModuleExists | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.2 | INTEGER | read-only | Indicates whether the power module specified exists or not. |
| powerModuleHealth | 1.3.6.1.4.1.2.3.51.2.2.4 | |||
| powerModuleHealthEntry | 1.3.6.1.4.1.2.3.51.2.2.4.1.1 | not-accessible | Power Module health entry | |
| powerModuleHealthTable | 1.3.6.1.4.1.2.3.51.2.2.4.1 | not-accessible | Table of power module health information. Contains the power health information for each power module. | |
| INT powerModuleIndex | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.1 | INTEGER | read-only | Power module index. |
| INT powerModuleState | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.3 | INTEGER | read-only | The health state for the power module. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Attention, Critical CLI - OK, Non-critical, Critical |
| INT powerOnOffBlade | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.7 | INTEGER | read-write | Control the power state of a specific blade. Off: Power Off Blade. On: Power On Blade. Softoff: Shut Down OS and Power Off Blade. This operation is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. The powerRestartBladePowerState MIB object should be used to check the power state of the blade(s) |
| INT powerPolicyActivate | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.7 | INTEGER | read-write | When read, this object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain. When set to a value of enabled(1), the power policy will be made the active one for the associated domain. A set of disabled(0) is not allowed. The SET may fail when the user goes from a less restrictive policy to a more restrictive policy, e.g. no power management to redundant power modules. This happens because the MM might have allocated more power for components in the less restrictive policy. Then if a user wants to go to a more restrictive policy, the power available may be lower than what was already allocated. The SET should always succeed if a user goes from a more restrictive to a less restrictive policy. |
| powerPolicyEntry | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1 | not-accessible | Power Policy Entry | |
| INT powerPolicyEstimatedUtilization | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.6 | INTEGER | read-only | The estimated utilization (as a percentage) based on current power usage. |
| INT powerPolicyIndex | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.1 | INTEGER | read-only | The unique idenitifier of a row in the powerPolicyTable. |
| powerPolicyInformation | 1.3.6.1.4.1.2.3.51.2.2.10.6 | |||
| INT powerPolicyMaxPowerLimit | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.5 | INTEGER | read-only | The maximum power available (in watts), based on the number of power modules and the Power Management Policy setting. |
| OCT powerPolicyName | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.3 | OCTET STRING | read-only | The short name of the power policy. The following are the possible names and their detailed description: Power Module Redundancy Intended for a single power source into the chassis where each Power Module is on its own dedicated circuit. Total allowed power draw is limited to one less than the number of Power Modules when more than one Power Module is present. One Power Module can fail without affecting blade operation. Multiple Power Module failures can cause the chassis to power off. Note that some blades may not be allowed to power on if doing so would exceed the policy power limit. Power Module Redundancy with Blade Throttling Allowed Very similar to the Power Module Redundancy policy. This policy allows you to draw more total power; however, capable blades may be allowed to throttle down if one Power Module fails. Basic Power Management Total allowed power is higher than other policies and is limited only by the total power capacity of all the Power Modules up to the maximum of chassis power rating. This is the least conservative approach, since it does not provide any protection for power source or Power Module failure. If any single power supply fails, blade and/or chassis operation may be affected. Power Source Redundancy Intended for dual power sources into the chassis. Total allowed power draw is limited to the capacity of two Power Modules. This is the most conservative approach and is recommended when all four Power Modules are installed. When the chassis is correctly wired with dual power sources, one power source can fail without affecting blade operation. Note that some blades may not be allowed to power on if doing so would exceed the policy power limit. Power Source Redundancy with Blade Throttling Allowed Very similar to the Power Source Redundancy policy. This policy allows you to draw more total power; however, capable blades may be allowed to throttle down if one power source fails. |
| INT powerPolicyPowerDomainNumber | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.2 | INTEGER | read-only | The power domain number which this row is associated with. |
| INT powerPolicyPwrSupplyFailureLimit | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.4 | INTEGER | read-only | The maximum number of power supplies that can fail in a chassis while still providing redundancy. |
| powerPolicyTable | 1.3.6.1.4.1.2.3.51.2.2.10.6.1 | not-accessible | Table of Power Policy information for all power domains. Reading this table can tell you about the available power policies that can be configured for a domain and also which is currently selected. The powerPolicyActivate object can also be SET to select which policy should be active for a given power domain. | |
| INT powerRestartBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.3 | INTEGER | read-only | Indicates whether the server blade specified exists or not. |
| INT powerRestartBladeHealthState | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.5 | INTEGER | read-only | The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The MM is currently in the process of discovering this blade. Communications Error: The MM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. |
| INT powerRestartBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.2 | INTEGER | read-only | The numeric blade ID. |
| OCT powerRestartBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.6 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| INT powerRestartBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.4 | INTEGER | read-only | Indicates the power state of the blade specified. If the state cannot be determined, the unknown(255) is returned. |
| INT powerRestartIndex | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.1 | INTEGER | read-only | Blade power restart table index. |
| processorBlade | 1.3.6.1.4.1.2.3.51.2.22.1 | |||
| OCT rbistBladesCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.3.49 | OCTET STRING | read-only | The blades that were communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. |
| OCT rbistBladesInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.33 | OCTET STRING | read-only | The blades that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. |
| OCT rbistChassisFansFunctional | 1.3.6.1.4.1.2.3.51.2.2.5.3.73 | OCTET STRING | read-only | The chassis fans installed on the chassis that were functional when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number supported. If it is installed and functional in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if one is installed and functional only in bay 1, and 2 are supported, the string would look like '10'. |
| OCT rbistChassisFansInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.65 | OCTET STRING | read-only | The chassis fans that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of chassis fans supported. If it is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if it is installed in bay 1, and 2 are supported, the string would look like '10'. |
| INT rbistChassisFansMUXAFunctional | 1.3.6.1.4.1.2.3.51.2.2.5.3.121 | INTEGER | read-only | Indicates whether chassis fan MUX A is functional |
| INT rbistChassisFansMUXAInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.120 | INTEGER | read-only | Indicates whether chassis fan MUX A is installed |
| INT rbistChassisFansMUXBFunctional | 1.3.6.1.4.1.2.3.51.2.2.5.3.123 | INTEGER | read-only | Indicates whether chassis fan MUX B is functional |
| INT rbistChassisFansMUXBInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.122 | INTEGER | read-only | Indicates whether chassis fan MUX B is installed |
| INT rbistEthernetPort1 | 1.3.6.1.4.1.2.3.51.2.2.5.3.11 | INTEGER | read-only | Standby MM BIST external ethernet port test result. The time of the last update can be obtained by querying rbistUpdateTime object. |
| INT rbistExternalI2CDevices | 1.3.6.1.4.1.2.3.51.2.2.5.3.14 | INTEGER | read-only | Standby MM BIST external I2C devices test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. |
| INT rbistInternalEthernetSwitch | 1.3.6.1.4.1.2.3.51.2.2.5.3.19 | INTEGER | read-only | Standby MM BIST internal external switch test result. The time of the last update can be obtained by querying rbistUpdateTime object. |
| OCT rbistLastUpdatePrimary | 1.3.6.1.4.1.2.3.51.2.2.5.3.201 | OCTET STRING | read-only | It is the time when the standby MM updated the last BIST results when it was still primary. |
| INT rbistLocalI2CBus | 1.3.6.1.4.1.2.3.51.2.2.5.3.7 | INTEGER | read-only | Standby MM BIST Local I2C bus test result. The time of the last update can be obtained by querying rbistUpdateTime object. |
| INT rbistLogicalNetworkLink | 1.3.6.1.4.1.2.3.51.2.2.5.3.30 | INTEGER | read-only | Standby MM BIST Logical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. |
| INT rbistOtherMMCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.3.77 | INTEGER | read-only | Indicates whether a standby MM was communicating when the standby MM was once primary. The time of the last update can be gotten from the object 'rbistUpdateTimePrimary'. |
| INT rbistOtherMMInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.76 | INTEGER | read-only | Indicates whether a standby MM was installed when the standby MM was once primary.The time of the last update can be obtained by querying rbistUpdateTimePrimary object. |
| INT rbistPhysicalNetworkLink | 1.3.6.1.4.1.2.3.51.2.2.5.3.29 | INTEGER | read-only | Standby MM BIST Physical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. |
| OCT rbistPowerModulesFunctional | 1.3.6.1.4.1.2.3.51.2.2.5.3.89 | OCTET STRING | read-only | The power modules that were functional on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed and functioning in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'. |
| OCT rbistPowerModulesInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.81 | OCTET STRING | read-only | The power modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'. |
| INT rbistRearLEDCardCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.3.75 | INTEGER | read-only | Indicates whether a rear LED card is communicating |
| INT rbistRearLEDCardInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.74 | INTEGER | read-only | Indicates whether a rear LED card is installed |
| INT rbistRtc | 1.3.6.1.4.1.2.3.51.2.2.5.3.5 | INTEGER | read-only | Standby MM BIST Real Time Clock test result. The time of the last update can be obtained by querying rbistUpdateTime object. |
| OCT rbistSwitchModulesCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.3.113 | OCTET STRING | read-only | The switch modules that are communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed and functioning in bays 1 and 3, and 4 switch modules were supported, the string would look like '1011'. |
| OCT rbistSwitchModulesInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.97 | OCTET STRING | read-only | The switch modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed in bays 1 and 3, and 4 switch modules were supported, the string would look like '1011'. |
| OCT rbistUpdateTime | 1.3.6.1.4.1.2.3.51.2.2.5.3.200 | OCTET STRING | read-only | It is the time when the standby MM updated the last BIST results. |
| INT rbsBlade1 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.4 | INTEGER | read-write | User has access to the blade in slot 1. |
| INT rbsBlade10 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.13 | INTEGER | read-write | User has access to the blade in slot 10. |
| INT rbsBlade11 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.14 | INTEGER | read-write | User has access to the blade in slot 11. |
| INT rbsBlade12 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.15 | INTEGER | read-write | User has access to the blade in slot 12. |
| INT rbsBlade13 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.16 | INTEGER | read-write | User has access to the blade in slot 13. |
| INT rbsBlade14 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.17 | INTEGER | read-write | User has access to the blade in slot 14. |
| INT rbsBlade2 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.5 | INTEGER | read-write | User has access to the blade in slot 2. |
| INT rbsBlade3 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.6 | INTEGER | read-write | User has access to the blade in slot 3. |
| INT rbsBlade4 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.7 | INTEGER | read-write | User has access to the blade in slot 4. |
| INT rbsBlade5 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.8 | INTEGER | read-write | User has access to the blade in slot 5. |
| INT rbsBlade6 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.9 | INTEGER | read-write | User has access to the blade in slot 6. |
| INT rbsBlade7 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.10 | INTEGER | read-write | User has access to the blade in slot 7. |
| INT rbsBlade8 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.11 | INTEGER | read-write | User has access to the blade in slot 8. |
| INT rbsBlade9 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.12 | INTEGER | read-write | User has access to the blade in slot 9. |
| INT rbsBladeAdministration | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.13 | INTEGER | read-write | User can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs. |
| INT rbsBladeConfiguration | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.12 | INTEGER | read-write | User can modify and save any blade configuration parameter. |
| INT rbsBladeOperator | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.10 | INTEGER | read-write | User has ability to browse status and properties of blades. |
| INT rbsBladeRemotePresence | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.11 | INTEGER | read-write | User has ability to access the blades remote console. The ability to issue the CLI console command to start an SOL session to a blade will also require this authority. |
| INT rbsChassis | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.3 | INTEGER | read-write | User has access to the MM and chassis functions. |
| INT rbsChassisAccountManagement | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.6 | INTEGER | read-write | User can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority. |
| INT rbsChassisAdministration | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.9 | INTEGER | read-write | User has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the user also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file. |
| INT rbsChassisConfiguration | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.8 | INTEGER | read-write | User can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the user also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file. |
| INT rbsChassisLogManagement | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.7 | INTEGER | read-write | User has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file. |
| INT rbsChassisOperator | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.5 | INTEGER | read-write | User has ability to browse status and properties of chassis components (MM, chassis fans, midplane, power modules). Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access. |
| ENT rbsEntryStatus | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.23 | EntryStatus | read-write | This object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table rbsEntryStatus = createRequest 2. Set roleId as required. Only one row will be allowed to be underCreation at one time, and it must have the next index in the table. valid(1) - Indicates that the group represented by this entry is available for use. createRequest(2) - A new entry will be created in this table for the specified group and the new entry will transition to the underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry. |
| INT rbsOperator | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.4 | INTEGER | read-write | User has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.). |
| INT rbsSupervisor | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.3 | INTEGER | read-write | User has no restrictions. |
| INT rbsSwitch1 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.18 | INTEGER | read-write | User has access to I/O module 1. |
| INT rbsSwitch10 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.27 | INTEGER | read-write | User has access to I/O module 10. |
| INT rbsSwitch2 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.19 | INTEGER | read-write | User has access to I/O module 2. |
| INT rbsSwitch3 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.20 | INTEGER | read-write | User has access to I/O module 3. |
| INT rbsSwitch4 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.21 | INTEGER | read-write | User has access to I/O module 4. |
| INT rbsSwitch5 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.22 | INTEGER | read-write | User has access to I/O module 5. |
| INT rbsSwitch6 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.23 | INTEGER | read-write | User has access to I/O module 6. |
| INT rbsSwitch7 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.24 | INTEGER | read-write | User has access to I/O module 7. |
| INT rbsSwitch8 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.25 | INTEGER | read-write | User has access to I/O module 8. |
| INT rbsSwitch9 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.26 | INTEGER | read-write | User has access to I/O module 9. |
| INT rbsSwitchModuleAdministration | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.16 | INTEGER | read-write | User can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet session to an I/O Module, or to restore factory defaults on an I/O Module. |
| INT rbsSwitchModuleConfiguration | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.15 | INTEGER | read-write | User can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module. |
| INT rbsSwitchModuleOperator | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.14 | INTEGER | read-write | User has ability to browse status and properties of I/O Modules, and to ping I/O Modules. |
| OCT readAuditLogAttribute | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.2 | OCTET STRING | read-only | A string of data detailing an audit eventlog's attribute. |
| readAuditLogEntry | 1.3.6.1.4.1.2.3.51.2.3.4.10.1 | not-accessible | Audit log table entry, new entries could be added for new items. | |
| OCT readAuditLogMessage | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.3 | OCTET STRING | read-only | A string of data detailing an audit event log message. |
| U32 readAuditLogNumber | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.1 | Unsigned32 | read-only | The audit log number. |
| U32 readAuditLogSequenceNum | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.4 | Unsigned32 | read-only | The sequence number for the audit event log. This number is the next sequence number when this event record was create. This number continues to grow, even if this event log is cleared, until it reaches the maximum value of 4294967295. The next sequence number following the maximum value is 1. |
| readAuditLogTable | 1.3.6.1.4.1.2.3.51.2.3.4.10 | not-accessible | Table of audit log entry information. Audit log includes the logs whose source is 'Audit' | |
| readCallHomeExclusionEventEntry | 1.3.6.1.4.1.2.3.51.2.23.6.1.1 | not-accessible | Call Home Exclusion Event table entry | |
| OCT readCallHomeExclusionEventID | 1.3.6.1.4.1.2.3.51.2.23.6.1.1.2 | OCTET STRING | read-only | The Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries. |
| INT readCallHomeExclusionEventIndex | 1.3.6.1.4.1.2.3.51.2.23.6.1.1.1 | INTEGER | read-only | The index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries. |
| readCallHomeExclusionEventTable | 1.3.6.1.4.1.2.3.51.2.23.6.1 | not-accessible | Table of Call Home Exclusion Event entries information. | |
| OCT readEnhancedEventLogAttribute | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.2 | OCTET STRING | read-only | A string of data detailing an event log's attribute, such as the Event ID and Call Home Flag. The Event ID is a hexadecimal number representing an specific or class of events. The call home flag indicates that the corresponding problem may result in a call home. |
| readEnhancedEventLogEntry | 1.3.6.1.4.1.2.3.51.2.3.4.6.1 | not-accessible | Enhaced Event log table entry, new entries could be added for new items. | |
| OCT readEnhancedEventLogMessage | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.3 | OCTET STRING | read-only | A string of data detailing an event log message. |
| U32 readEnhancedEventLogNumber | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.1 | Unsigned32 | read-only | The event log number for the enhanced event log. |
| U32 readEnhancedEventLogSequenceNum | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.4 | Unsigned32 | read-only | The sequence number for the enhanced event log. This number is the next sequence number when this event record was create. This number continues to grow, even if this event log is cleared, until it reaches the maximum value of 4294967295. The next sequence number following the maximum value is 1. |
| readEnhancedEventLogTable | 1.3.6.1.4.1.2.3.51.2.3.4.6 | not-accessible | Table of enhanced event log entry information. | |
| readEventLogAuxEntry | 1.3.6.1.4.1.2.3.51.2.3.4.14.1 | not-accessible | Event log auxiliary table entry, new entries could be added for new items. | |
| OCT readEventLogAuxMessage | 1.3.6.1.4.1.2.3.51.2.3.4.14.1.3 | OCTET STRING | read-only | A string of data detailing the auxiliary information from the log event. |
| INT readEventLogAuxNumber | 1.3.6.1.4.1.2.3.51.2.3.4.14.1.1 | INTEGER | read-only | The system log auxiliary index number. To relate this information to the system log, match Sequence number of this entry to the Sequence number of the system log entry. |
| U32 readEventLogAuxSequenceNum | 1.3.6.1.4.1.2.3.51.2.3.4.14.1.2 | Unsigned32 | read-only | The sequence number for the system event log that contains this Auxiliary information. Value is from 1 through 4294967295 and then wraps. |
| readEventLogAuxTable | 1.3.6.1.4.1.2.3.51.2.3.4.14 | not-accessible | Table of system log entry auxiliary information. | |
| readEventLogEntry | 1.3.6.1.4.1.2.3.51.2.3.4.2.1 | not-accessible | Event log table entry | |
| INT readEventLogIndex | 1.3.6.1.4.1.2.3.51.2.3.4.2.1.1 | INTEGER | read-only | The event log index number. |
| OCT readEventLogString | 1.3.6.1.4.1.2.3.51.2.3.4.2.1.2 | OCTET STRING | read-only | A string of data detailing an event. |
| readEventLogTable | 1.3.6.1.4.1.2.3.51.2.3.4.2 | not-accessible | Table of event log entry information. | |
| OCT readSystemLogAttribute | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.2 | OCTET STRING | read-only | A string of data detailing an system event log's attribute. |
| readSystemLogEntry | 1.3.6.1.4.1.2.3.51.2.3.4.12.1 | not-accessible | System log table entry, new entries could be added for new items. | |
| OCT readSystemLogMessage | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.3 | OCTET STRING | read-only | A string of data detailing an system event log message. |
| U32 readSystemLogNumber | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.1 | Unsigned32 | read-only | The system log index number. |
| U32 readSystemLogSequenceNum | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.4 | Unsigned32 | read-only | The sequence number for the system event log. This number is the next sequence number when this event record was create. This number continues to grow, even if this event log is cleared, until it reaches the maximum value of 4294967295. The next sequence number following the maximum value is 1. |
| readSystemLogTable | 1.3.6.1.4.1.2.3.51.2.3.4.12 | not-accessible | Table of system log entry information. System log includes the logs whose source is other than 'Audit' | |
| rearLEDCardHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.9 | |||
| OCT rearLEDCardHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.9.12 | OCTET STRING | read-only | Rear LED card hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. |
| OCT rearLEDCardHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.9.4 | OCTET STRING | read-only | Rear LED card hardware VPD FRU number. For consistent results, view as a table and not as individual entries. |
| OCT rearLEDCardHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.9.20 | OCTET STRING | read-only | Rear LED card hardware VPD FRU Serial. |
| INT rearLEDCardHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.9.5 | INTEGER | read-only | Rear LED card hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. |
| OCT rearLEDCardHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.9.17 | OCTET STRING | read-only | Rear LED card hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. |
| OCT rearLEDCardHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.9.3 | OCTET STRING | read-only | Rear LED card hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. |
| OCT rearLEDCardHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.9.9 | OCTET STRING | read-only | Rear LED card hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. |
| OCT rearLEDCardHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.9.18 | OCTET STRING | read-only | Rear LED card hardware VPD Manufacture Date. |
| OCT rearLEDCardHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.9.19 | OCTET STRING | read-only | Rear LED card hardware VPD Part Number. |
| OCT rearLEDCardHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.9.10 | OCTET STRING | read-only | Rear LED card hardware VPD product ID. For consistent results, view as a table and not as individual entries. |
| OCT rearLEDCardHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.9.11 | OCTET STRING | read-only | Rear LED card hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. |
| OCT rearLEDCardHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.9.8 | OCTET STRING | read-only | Rear LED card hardware VPD UUID. For consistent results, view as a table and not as individual entries. |
| OCT rearLEDCardTempAvg | 1.3.6.1.4.1.2.3.51.2.2.1.5.1 | OCTET STRING | read-only | The average rear LED card temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. |
| OCT rearLEDCardTempMax | 1.3.6.1.4.1.2.3.51.2.2.1.5.3 | OCTET STRING | read-only | The maximum rear LED card temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. |
| OCT rearLEDCardTempMin | 1.3.6.1.4.1.2.3.51.2.2.1.5.2 | OCTET STRING | read-only | The minimum rear LED card temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. |
| rearLEDCardThermalTrendingEntry | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1 | not-accessible | Rear LED Card Thermal Trending entry. | |
| INT rearLEDCardThermalTrendingIndex | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.1 | INTEGER | read-only | Rear LED Card Thermal Trending Table Index. |
| rearLEDCardThermalTrendingTable | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10 | not-accessible | Table of rear LED card Thermal Trending Information. | |
| OCT rearLEDCardThermalTrendingTemperatureAvg | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.3 | OCTET STRING | read-only | Rear LED Card Thermal Trending Table Average Temperature. |
| OCT rearLEDCardThermalTrendingTemperatureMax | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.5 | OCTET STRING | read-only | Rear LED Card Thermal Trending Table Maximum Temperature. |
| OCT rearLEDCardThermalTrendingTemperatureMin | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.4 | OCTET STRING | read-only | Rear LED Card Thermal Trending Table Minumum Temperature. |
| OCT rearLEDCardThermalTrendingTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.2 | OCTET STRING | read-only | Rear LED Card Thermal Trending Table Sample Timestamp. |
| INT reloadAllVpdData | 1.3.6.1.4.1.2.3.51.2.2.21.23.1 | INTEGER | read-write | Reload all VPD data (firmware, hardware, MAC address, WWN/GUID and other Unique ID). NOTE: The value returned for the GET command is meaningless. |
| INT reloadFwVpdData | 1.3.6.1.4.1.2.3.51.2.2.21.23.2 | INTEGER | read-write | Reload firmware VPD data. NOTE: The value returned for the GET command is meaningless. |
| INT reloadHwVpdData | 1.3.6.1.4.1.2.3.51.2.2.21.23.3 | INTEGER | read-write | Reload hardware VPD data. NOTE: The value returned for the GET command is meaningless. |
| INT reloadMACAddress | 1.3.6.1.4.1.2.3.51.2.2.21.23.4 | INTEGER | read-write | Reload blade MAC addresses. NOTE: The value returned for the GET command is meaningless. |
| reloadVpdData | 1.3.6.1.4.1.2.3.51.2.2.21.23 | |||
| INT reloadWwnGuidVpdData | 1.3.6.1.4.1.2.3.51.2.2.21.23.5 | INTEGER | read-write | Reload blade and I/O module WWN/GUID and other VPD data. NOTE: The value returned for the GET command is meaningless. |
| remoteAccessConfig | 1.3.6.1.4.1.2.3.51.2.4.1 | |||
| INT remoteAccessIdEntryAction | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.17 | INTEGER | read-write | Actions that only a supervisor or chassis user account manager can perform for each user id: Enable - enables an account in the Disabled state Disable - disables an account in the Active or Locked state Unlock - unlock an account in the Locked state NOTE: The disable action does not apply to supervisor or chassis user account manager accounts. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT remoteAccessIdEntryDormant | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.15 | INTEGER | read-only | Indicates if the user account has been inactive for a specified amount of time based on inactivityAlertDisablePeriod in the customSecuritySettings section. |
| INT remoteAccessIdEntryIndex | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.1 | INTEGER | read-only | Index for Remote access entry. |
| INT remoteAccessIdEntryIPMIProvisioned | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.21 | INTEGER | read-write | Indicates if the user has been provisioned as an IPMI account. If this is user is provisioned as an IPMI account, the nodes (scope) and authorities will be determined by the scope and authorities of the permission groups to which this user belongs. These can be seen in the remoteAccessRBSscopeTable and remoteAccessRBSroleTable for the permission groups to which this user is assigned. If the userid is longer than 16 characters or there are more than 12 user accounts enabled for IPMI provisioning, setting the value to yes will return an error. When provisioning an IPMI account by setting this object to yes(1), the SNMPv3 account is also automatically provisioned. |
| OCT remoteAccessIdEntryLastLogin | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.12 | OCTET STRING | read-only | Timestamp for the last successful login by the user. |
| INT remoteAccessIdEntryLoggedIn | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.11 | INTEGER | read-only | Indicates if user is currently logged in or not. |
| INT remoteAccessIdEntryMaxSessions | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.19 | INTEGER | read-write | The maximum number of simultaneous active sessions allowed for the user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20. |
| OCT remoteAccessIdEntryPassword | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.3 | OCTET STRING | read-write | Remote access password. The password rules are dictated by a combination of the chassis security policy setting (securityPolicySetting) and the user account security level setting (accountSecurityLevel). Refer to object complexPasswordRules to understand the requirements. NOTE: Value returned by the GET command is meaningless for this MIB object. |
| OCT remoteAccessIdEntryPermgroups | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.10 | OCTET STRING | read-write | A list of permission groups for this userid, delmited with a '|' |
| INT remoteAccessIdEntryPwdCompliant | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.13 | INTEGER | read-only | Indicates if user complies with all of the password rules currently in effect. |
| OCT remoteAccessIdEntryPwdExp | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.14 | OCTET STRING | read-only | The number of days until the user's current password expires. |
| INT remoteAccessIdEntrySessionCount | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.18 | INTEGER | read-only | The number of sessions the user is currently logged in to. |
| INT remoteAccessIdEntrySNMPv3Provisioned | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.22 | INTEGER | read-write | Indicates if the user has been provisioned as an SNMPv3 account. If this is user is provisioned as an SNMPv3 account, the nodes (scope) and authorities will be determined by the scope and authorities of the permission groups to which this user belongs. These can be seen in the remoteAccessRBSscopeTable and remoteAccessRBSroleTable for the permission groups to which this user is assigned. If the userid is longer than 16 characters or there are more than 12 user accounts enabled for SNMPv3 provisioning, setting the value to yes will return an error. When provisioning a SNMPv3 account by setting this object to yes(1), the IPMI account is also automatically provisioned. |
| INT remoteAccessIdEntryState | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.16 | INTEGER | read-only | Indicates the state of the user: Active - normal state Disabled - user cannot use account until enabled by a supervisor or chassis user account manager. An account can get disabled after being dormant for a specified amount of time OR as a result of a supervisor or chassis user account manager disabling it. Locked - account is temporarily locked due to repeated unsuccessful login attempts as specified by lockoutPeriod in the customSecuritySettings section. Account can be unlocked by a supervisor or chassis user account manager OR can be automatically unlocked after the lockoutPeriod expires. NOTE: The disable action does not apply to supervisor or chassis user account manager accounts. |
| ENT remoteAccessIdEntryStatus | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.20 | EntryStatus | read-write | This object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table remoteAccessIdEntryStatus = createRequest 2. Set remoteAccessId as required. The remoteAccessIdUserId and the remoteAccessIdPassword must be set before the entry becomes valid. To set the remoteAccessIdsEntryPermgroups or remoteAccessIdsEntryMaxSessions before the entry is valid, set these fields before both the password and userId are set. Only one row will be allowed to be underCreation at one time, and it must have the next index in the table. valid(1) - Indicates that the group represented by this entry is available for use. createRequest(2) - A new entry will be created in this table for the specified group and the new entry will transition to the underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry. |
| OCT remoteAccessIdEntryUserId | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.2 | OCTET STRING | read-write | Remote access entry null terminated string that contains the userid. It must not be a duplicate of any previously configured ones. This field is only allowed to be set when the entry status is under creation. |
| remoteAccessIds | 1.3.6.1.4.1.2.3.51.2.4.1.4 | |||
| remoteAccessIdsEntry | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1 | not-accessible | Remote access entries. | |
| remoteAccessIdsTable | 1.3.6.1.4.1.2.3.51.2.4.1.4.1 | not-accessible | Table of remote access profiles. This table lets you to configure all login profiles. NOTE: By default, the management module comes configured with one login profile that allows remote access using a login ID of 'USERID' and a password of 'PASSW0RD' (the 0 is a zero). To avoid a potential security exposure, we strongly recommend that you change this default Login Profile to values of your choice. | |
| remoteAccessRBSroleEntry | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1 | not-accessible | User Role entries. | |
| remoteAccessRBSroleTable | 1.3.6.1.4.1.2.3.51.2.4.1.4.3 | not-accessible | Table of RBS User Role profiles. | |
| remoteAccessRBSscopeEntry | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1 | not-accessible | User Scope entries. | |
| remoteAccessRBSscopeTable | 1.3.6.1.4.1.2.3.51.2.4.1.4.4 | not-accessible | Table of RBS User Scope profiles. | |
| OCT remoteAlertIdEmailAddr | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.9 | OCTET STRING | read-write | A null terminated string that contains an E-Mail Address. For example, 'xyz@us.ibm.com'. Used only for an E-mail over LAN notification type. |
| INT remoteAlertIdEntryIndex | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.1 | INTEGER | read-only | Index for remote alert entry. |
| OCT remoteAlertIdEntryIpOrHostAddress | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.3 | OCTET STRING | read-write | A null terminated string that either contains an IP address of the form '1.2.3.4' or a host name (if DNS is enabled) for the alert entry. |
| INT remoteAlertIdEntryNotificationType | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.5 | INTEGER | read-write | Remote alert entry notification method. Types include unknown when the type can't be determined (read-only), snmpOverLan for an SNMP alert over ethernet, and emailOverLan for a E-Mail alert over ethernet. |
| INT remoteAlertIdEntrySelectiveAlert | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.13 | INTEGER | read-write | Remote alert entry selective alert setting. A value of critOnlyAlerts will only send critical alerts to this remote alert recipient, a value of allAlerts will send all alerts to this remote alert recipient. |
| INT remoteAlertIdEntryStatus | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.2 | INTEGER | read-write | Remote alert entry status, invalid means entry not defined yet, disabledAndValid means entry defined but not enabled to send an alert, enabledAndValid means entry defined and enabled to send an alert. |
| OCT remoteAlertIdEntryTextDescription | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.4 | OCTET STRING | read-write | A null terminated string that contains a text description of this entry. |
| remoteAlertIds | 1.3.6.1.4.1.2.3.51.2.4.1.3 | |||
| remoteAlertIdsEntry | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1 | not-accessible | Remote alert entries. | |
| remoteAlertIdsTable | 1.3.6.1.4.1.2.3.51.2.4.1.3.1 | not-accessible | Table of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients. NOTE: All selected alert events will be sent to all enabled alert recipients. | |
| INT remoteAlertRetryCount | 1.3.6.1.4.1.2.3.51.2.4.1.1.4 | INTEGER | read-write | Number of additional times a remote alert will be retried if not successfully sent. A value of zero indicates no retries will be attempted. |
| INT remoteAlertRetryDelay | 1.3.6.1.4.1.2.3.51.2.4.1.1.3 | INTEGER | read-write | Number in seconds to delay between retries if sending a remote alert is unsuccessful. |
| remoteAlerts | 1.3.6.1.4.1.2.3.51.2.4.2 | |||
| remoteAlertsCrit | 1.3.6.1.4.1.2.3.51.2.4.2.1 | |||
| remoteAlertsNonCrit | 1.3.6.1.4.1.2.3.51.2.4.2.2 | |||
| remoteAlertsSystem | 1.3.6.1.4.1.2.3.51.2.4.2.3 | |||
| INT resetSPConfigAndRestart | 1.3.6.1.4.1.2.3.51.2.7.20 | INTEGER | read-write | Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT resetSPConfigAndRestartSaveLogs | 1.3.6.1.4.1.2.3.51.2.7.21 | INTEGER | read-write | Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. The logs will be saved. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT restartBlade | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.8 | INTEGER | read-write | Restart a blade. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT restartBladeClearNVRAM | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.11 | INTEGER | read-write | Restart a blade and set NVRAM to default values. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT restartBladeInvokeDiags | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.12 | INTEGER | read-write | Restart a blade and boot into diagnostic mode. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT restartBladeInvokeDiagsFromDefaultBootList | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.13 | INTEGER | read-write | Restart a blade and boot into diagnostic mode from Default Boot List as defined on the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT restartBladeNMI | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.10 | INTEGER | read-write | Issue an NMI to the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT restartBladeSMP | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.9 | INTEGER | read-write | Restart a blade's system management processor. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT restartBladeToSMSBootMenu | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.14 | INTEGER | read-write | Restart a blade to SMS boot menu. This option is not supported on all blades, and at the time of this MIB definition was only supported on POWER blades. This object is deprecated and please use the bladePowerEnableSMSBootMenu object. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| restartReset | 1.3.6.1.4.1.2.3.51.2.7 | |||
| INT restartSPImmediately | 1.3.6.1.4.1.2.3.51.2.7.4 | INTEGER | read-write | Restart the MM immediately. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT restartStandbyMM | 1.3.6.1.4.1.2.3.51.2.7.5 | INTEGER | read-write | Restarts the Standby MM from the Primary MM. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a standby MM. |
| INT rmAllCallHomeExclusionEvent | 1.3.6.1.4.1.2.3.51.2.23.6.4 | INTEGER | read-write | Remove all Event IDs from the Call Home Exclusion List. Events on the exclusion list can not be removed if autoFtpMode is disabled. If Service Advisor Terms and Conditions are accepted, events on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| OCT rmCallHomeExclusionEvent | 1.3.6.1.4.1.2.3.51.2.23.6.3 | OCTET STRING | read-write | Remove one call home Event ID from the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. An event on the exclusion list can not be removed if autoFtpMode is disabled. If Service Advisor Terms and Conditions are accepted, an event on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| rmmBistAndChassisStatus | 1.3.6.1.4.1.2.3.51.2.2.5.3 | |||
| OCT roleId | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.2 | OCTET STRING | read-write | Remote access RBS role entry null terminated string that contains the permission group ID. It must not be a duplicate of any previously configured ones. This field is only allowed to be set when the entry status is under creation. |
| INT roleIndex | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.1 | INTEGER | read-only | Index for RBS User Role entry. |
| scalableComplexEntry | 1.3.6.1.4.1.2.3.51.2.24.1.1 | not-accessible | Scalable complex information. | |
| INT scalableComplexIdentifier | 1.3.6.1.4.1.2.3.51.2.24.1.1.2 | INTEGER | read-only | The unique numeric identifier for a complex installed in the chassis. |
| INT scalableComplexNodeHealthState | 1.3.6.1.4.1.2.3.51.2.24.1.1.4 | INTEGER | read-only | The system health state for the component. Unknown: Component is in an undefined state. Good: Component is operating normally. Warning: One or more outstanding warnings exist for this component. Critical: One or more outstanding critical events for this component. Kernel Mode: Component is in kernel mode. Discovering: The MM is currently in the process of discovering this component. Communications Error: The MM failed to communicate with this component. No Power: No power to the component's domain. Flashing: Flashing in progress. Initialization Failure: Component failed to initialized. Insufficient Power: Not enough power is left in the component's domain to power the component. Power Denied: Power was denied to the component. Maintenance Mode: Node is undergoing a service operation and should not be updated or powered on/off. Firehose Dump: Node is undergoing a storage save operation and should not be udpated or powered on/off |
| OCT scalableComplexNodeName | 1.3.6.1.4.1.2.3.51.2.24.1.1.3 | OCTET STRING | read-only | The name of the node as a null terminated string. |
| INT scalableComplexNodePowerState | 1.3.6.1.4.1.2.3.51.2.24.1.1.5 | INTEGER | read-only | Indicates the power state of the node. |
| OCT scalableComplexNodeResources | 1.3.6.1.4.1.2.3.51.2.24.1.1.6 | OCTET STRING | read-only | A string providing a summary overview of the resources provided by this node. |
| scalableComplexTable | 1.3.6.1.4.1.2.3.51.2.24.1 | not-accessible | Table of scalable complex information. This table provides information related to the scalable complexes installed in the chassis. | |
| OCT scalableComplexTopologyPath | 1.3.6.1.4.1.2.3.51.2.24.1.1.1 | OCTET STRING | read-only | The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| scaling | 1.3.6.1.4.1.2.3.51.2.24 | |||
| OCT scopeId | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.2 | OCTET STRING | read-only | Remote access RBS scope entry null terminated string that contains the permission group ID. |
| INT scopeIndex | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.1 | INTEGER | read-only | Index for RBS User Scope Entry. |
| INT secureCommandModeEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.3 | INTEGER | read-write | Set Secure TCP Command Mode number of connections. MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable. |
| INT secureCommandModePortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.9 | INTEGER | read-write | Secure TCP Command Mode port number. Default value is 6091. Change will take effect immediately. |
| INT securityPolicySetting | 1.3.6.1.4.1.2.3.51.2.4.3.5.1 | INTEGER | read-write | Determines chassis security policy. legacy mode(0) or secure mode(1). unknown(255) returned when policy can't be set or determined. |
| INT securityPolicyState | 1.3.6.1.4.1.2.3.51.2.4.3.5.2 | INTEGER | read-only | Determines chassis security policy state. If pending(0), check securityPolicyStatusTable for details on actions needed, to make fully active. |
| INT securityPolicyStatusBayId | 1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.3 | INTEGER | read-only | Bay location of specific component. NOTE: securityPolicyStatusComponentType enumeration also indicates location. |
| INT securityPolicyStatusComponentType | 1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.2 | INTEGER | read-only | Indicates Component type and location with pending security status. |
| OCT securityPolicyStatusDetails | 1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.5 | OCTET STRING | read-only | Details of pending security status for the component. |
| securityPolicyStatusEntry | 1.3.6.1.4.1.2.3.51.2.4.3.5.3.1 | not-accessible | Pending security policy status entry | |
| INT securityPolicyStatusIndex | 1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.1 | INTEGER | read-only | Pending Security policy status index. |
| OCT securityPolicyStatusSummary | 1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.4 | OCTET STRING | read-only | Summary of pending security status for the component. |
| securityPolicyStatusTable | 1.3.6.1.4.1.2.3.51.2.4.3.5.3 | not-accessible | Table of pending security policy status. | |
| securitySettings | 1.3.6.1.4.1.2.3.51.2.4.3 | |||
| serialPortCfg | 1.3.6.1.4.1.2.3.51.2.4.1.2 | |||
| service | 1.3.6.1.4.1.2.3.51.2.23 | |||
| serviceAdvisor | 1.3.6.1.4.1.2.3.51.2.23.4 | |||
| INT serviceAdvisorEnable | 1.3.6.1.4.1.2.3.51.2.23.4.1.2 | INTEGER | read-write | Disable/Enable IBM Support. The User Agreement must be accepted and the contact information must be set before the IBM Support function of Service Advisor can be enabled. |
| INT serviceDataBladeExists | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.3 | INTEGER | read-only | Indicates whether the blade specified exists or not. |
| INT serviceDataBladeId | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.2 | INTEGER | read-only | The numeric blade ID. |
| OCT serviceDataBladeName | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.5 | OCTET STRING | read-only | The name of the blade as a string. |
| INT serviceDataBladePowerState | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.4 | INTEGER | read-only | Indicates whether the blade specified is powered on or not. If the MM is experiencing a communication problem with the blade, the state may be returned as unknown(255) |
| OCT serviceDataDumpCapabilityMask | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.9 | OCTET STRING | read-only | Indicates whether the blade has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to the MM from the blade. The values and meanings are as follows: 0000 0000 means this blade does not support any at all. 0000 0001 means this blade supports 'processor' type and the file remains on the blade. 0000 0010 means this blade supports 'platform' type and the file remains on the blade 0000 0100 means this blade supports 'partition' type and the file remians on the blade 0000 1000 means this blade supports 'processor' type and the file can be transferred to the MM. 0001 0000 means this blade supports 'platform' type and the file can be transferred to the MM. 0010 0000 means this blade supports 'partition' type and the file can be transferred to the MM 0100 0000 means this blade supports 'serviceData' type and the file can be transferred to the MM For example, the returned value of 01111000 means this blade supports 'processor','platform', 'partition' and 'serviceData' types, and the file can be transferred to the MM |
| INT serviceDataDumpInitiate | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.7 | INTEGER | read-write | Initiates a type of dump collection to be initiated for the blade. NOTE: Not all blades support this, please check serviceDataDumpCapabilityMask OID to see if the action is supported on this blade. When the dump file is created, the node transfers it to the /tftproot/service directory on the CMM. Only one file can be moved to this directory at a time, so please use the fileManagement MIB information to check if the file has been completed. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT serviceDataDumpInProgress | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.10 | INTEGER | read-only | An indicator as to whether a blade dump is in progress for the specified blade. This object ONLY applies to dumps that can be triggered by the MM and where the dump file is transferred to the MM filesystem upon completion. See the serviceDataDumpCapabilityMask object for support levels. The flag that this MIB object represents will be set on when the IPMI command is sent to the blade indicating 'init dump' and will be cleared upon receiving the valid dump file from the blade or the creation of the text file indicating the problem encountered. If it cannot be determined if the dump is in progress, the unknown(255) value is returned. |
| INT serviceDataDumpRetrieve | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.8 | INTEGER | read-write | Retrieve a type of service data file from blade to MM. NOTE: This OID only is valid for the last four bit mask designations listed in the serviceDataDumpCapabilityMask OID. The dump file is transfered to the /tftproot/service directory on the CMM. Only one file can be moved to this directory at a time, so please use the fileManagement MIB information to check if the file has been completed. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT serviceDataIndex | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.1 | INTEGER | read-only | Blade service date index. |
| serviceSupportCenter | 1.3.6.1.4.1.2.3.51.2.23.4.2 | |||
| INT sftpEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.18 | INTEGER | read-write | Disable/Enable SFTP. |
| INT slpAddrType | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.5 | INTEGER | read-write | Set SLP address type to 0 (multicast) or 1 (broadcast). Note that when slpAddrType is set to broadcast value then the multicast address set in slpMulticastAddr will be ignored. |
| INT slpEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.7 | INTEGER | read-write | Disable/Enable Service Location Protocol. NOTE: Change to Service Location Protocol will take effect after the next restart of the MM. |
| INT slpPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.19 | INTEGER | read-write | Service Location Protocol port number. Default value is 427. NOTE: This value is normally required to be 427 to interoperate properly with other SLP enabled applications. |
| OCT smBootRomVpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.6 | OCTET STRING | read-only | Switch module firmware build date. |
| OCT smBootRomVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.5 | OCTET STRING | read-only | Switch module firmware build ID. |
| smBootRomVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1 | not-accessible | Switch module boot ROM VPD table entry | |
| INT smBootRomVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.3 | INTEGER | read-only | Indicates whether the switch module specified exists or not. |
| INT smBootRomVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.2 | INTEGER | read-only | The switch module numeric identifier. |
| INT smBootRomVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.1 | INTEGER | read-only | Switch module boot ROM VPD entry index. |
| OCT smBootRomVpdRevisionNumber | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.7 | OCTET STRING | read-only | Switch module firmware revision number. |
| INT smBootRomVpdSwitchSubType | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.8 | INTEGER | read-only | Indicates the subtype of switch module installed. |
| INT smBootRomVpdSwitchType | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.4 | INTEGER | read-only | Indicates the type of switch module installed. |
| smBootRomVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.7.2 | not-accessible | Switch module boot ROM VPD information table. | |
| INT smCfgCtrlEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.6 | INTEGER | read-write | Switch module configuration control. When set to enabled, only the MM can manage the module. This MIB object can not be set, if MM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and external management is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(0) will be returned. |
| INT smCfgCtrlOnResetEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.9 | INTEGER | read-write | Switch module configuration control on resets (default and unsolicited). When set to enabled, the factory default IP configuration will become active when the I/O module is reset to factory defaults by either the management module or the I/O module. If an I/O module reset is initiated by a source other than the management module then the previous IP configuration will be in affect. In both these cases the MM will lose IP communications with the IOM. This MIB object can not be set, if MM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(1) will be returned. |
| smControlEntry | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1 | not-accessible | Switch module control table entry | |
| INT smControlIndex | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.1 | INTEGER | read-only | Switch module control table index. |
| smControlTable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1 | not-accessible | Switch module control table. | |
| IP smCurrentGateway | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.8 | IpAddress | read-only | The switch module current IP gateway. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. |
| IP smCurrentIPAddr | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.6 | IpAddress | read-only | The switch module current IP address. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. |
| INT smCurrentIPConfigMethod | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.9 | INTEGER | read-only | The switch module current IP configuration method. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. |
| smCurrentIPInfoEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1 | not-accessible | Switch module current IP table entry. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | |
| INT smCurrentIPInfoExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.3 | INTEGER | read-only | Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. |
| INT smCurrentIPInfoId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.2 | INTEGER | read-only | The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. |
| INT smCurrentIPInfoIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.1 | INTEGER | read-only | Switch module current IP info index. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. |
| INT smCurrentIPInfoPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.4 | INTEGER | read-only | Indicates whether the I/O Module specified is powered on or not. The value 'shutdownInProgress' is for the I/O Module that may take some time to transition from 'poweron' to 'poweroff'. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. |
| smCurrentIPInfoTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1 | not-accessible | Switch module current IP information. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | |
| IP smCurrentSubnetMask | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.7 | IpAddress | read-only | The switch module current subnet mask. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. |
| INT smDHCPv6ConfigEnabled | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.4 | INTEGER | read-write | Enables/Disables DHCPv6 address configuration support on the switch module. |
| INT smExtEthPortsEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.7 | INTEGER | read-write | Switch module non-management ethernet ports enabled or disabled. This MIB object can not be set, if MM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and External Port Access is protected. |
| smFirmwareAnalysisEntry | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1 | not-accessible | IOM firmware analysis information. | |
| OCT smFirmwareAnalysisFirmwareType | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.4 | OCTET STRING | read-only | The IOM firmware type. |
| OCT smFirmwareAnalysisFirmwareVersion | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.5 | OCTET STRING | read-only | The IOM firmware version. |
| INT smFirmwareAnalysisIndex | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.1 | INTEGER | read-only | The index for the IOM firmware levels. |
| OCT smFirmwareAnalysisProductId | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.2 | OCTET STRING | read-only | The IOM product id. |
| OCT smFirmwareAnalysisProductName | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.3 | OCTET STRING | read-only | The IOM product name. |
| OCT smFirmwareAnalysisReleaseDate | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.6 | OCTET STRING | read-only | The IOM release date. |
| smFirmwareAnalysisTable | 1.3.6.1.4.1.2.3.51.2.2.23.2.11 | not-accessible | Table of firmware levels of installed IOMs. This information is grouped by Product Id and includes two or more IOMs with the same product id. This information is intended to be used in determining which components firmware may need upgrade. | |
| OCT smFirmwareAnalysisTopology | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.7 | OCTET STRING | read-only | The IOM topology. |
| smFirmwareInfoEntry | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1 | not-accessible | Switch Module firmware image information table entry | |
| INT smFirmwareInfoImageIndex | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.3 | INTEGER | read-only | Switch Module firmware image index. |
| OCT smFirmwareInfoImageName | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.4 | OCTET STRING | read-write | Switch Module firmware image name |
| INT smFirmwareInfoIndex | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.1 | INTEGER | read-only | Sequence index in the firmware table. |
| INT smFirmwareInfoModIndex | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.2 | INTEGER | read-only | Switch Module number. |
| smFirmwareInformation | 1.3.6.1.4.1.2.3.51.2.22.8.1 | |||
| smFirmwareInfoTable | 1.3.6.1.4.1.2.3.51.2.22.8.1.1 | not-accessible | Switch Module firmware image information. | |
| smFirmwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.7 | |||
| OCT smFourPortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.8 | OCTET STRING | read-only | Available speed setting per port for Switch Module 4. If there is more than one setting, the speeds are separated by a comma and then a space. |
| INT smFourPortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.12 | INTEGER | read-only | The length (in meters) of the cable supported by this port for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports. |
| OCT smFourPortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.13 | OCTET STRING | read-only | External cable type for this port, for example, active copper or passive fiber. |
| INT smFourPortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.15 | INTEGER | read-only | Compatibility of the external cable that is plugged into the port. |
| INT smFourPortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.16 | INTEGER | read-only | Data rate supported for this port. |
| smFourPortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1 | not-accessible | Switch Module 4 port configuration information table entry | |
| INT smFourPortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.1 | INTEGER | read-only | Switch Module 4 port sequence index. |
| OCT smFourPortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.2 | OCTET STRING | read-only | Switch Module 4 port label |
| INT smFourPortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.4 | INTEGER | read-write | Current port link setting for Switch Module 4. |
| INT smFourPortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.5 | INTEGER | read-only | Current port link state of Switch Module 4. |
| INT smFourPortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.9 | INTEGER | read-only | Port media type of Switch Module 4. |
| INT smFourPortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.10 | INTEGER | read-only | Port protocol of Switch Module 4. |
| OCT smFourPortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.6 | OCTET STRING | read-write | Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smFourPortCfgAvailSpeeds are applicable to setting this mib object. |
| OCT smFourPortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.7 | OCTET STRING | read-only | Current port speed of Switch Module 4. |
| smFourPortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1 | not-accessible | Switch Module 4 port configuration information. Note: This option is not supported on all I/O modules. | |
| INT smFourPortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.3 | INTEGER | read-only | Switch Module 4 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. |
| OCT smFourPortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.14 | OCTET STRING | read-only | The cable manufacturer. |
| INT smFourPortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.11 | INTEGER | read-only | The width of the port in terms of how many combined cables are present for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. |
| smHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.6 | |||
| OCT smHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.2 | OCTET STRING | read-only | Switch module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. |
| OCT smHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.15 | OCTET STRING | read-only | Switch module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. |
| smHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1 | not-accessible | Switch module hardware VPD entry. For consistent results, view as a table and not as individual entries. | |
| OCT smHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.4 | OCTET STRING | read-only | Switch module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. |
| OCT smHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.11 | OCTET STRING | read-only | Switch module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. |
| INT smHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.5 | INTEGER | read-only | Switch module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. |
| OCT smHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.20 | OCTET STRING | read-only | Switch module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. |
| INT smHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.1 | INTEGER | read-only | Switch module hardware VPD index. For consistent results, view as a table and not as individual entries. |
| OCT smHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.3 | OCTET STRING | read-only | Switch module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. |
| OCT smHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.12 | OCTET STRING | read-only | Switch module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. |
| OCT smHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.9 | OCTET STRING | read-only | Switch module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. |
| OCT smHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.10 | OCTET STRING | read-only | Switch module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. |
| OCT smHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.13 | OCTET STRING | read-only | Switch module hardware VPD product ID. For consistent results, view as a table and not as individual entries. |
| OCT smHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.14 | OCTET STRING | read-only | Switch module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. |
| smHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.6.1 | not-accessible | Table of the switch module hardware components. For consistent results, view as a table and not as individual entries. | |
| OCT smHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.8 | OCTET STRING | read-only | Switch module hardware VPD UUID. For consistent results, view as a table and not as individual entries. |
| INT smHardwareVpdWidth | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.18 | INTEGER | read-only | The width of the switch module hardware. For consistent results, view as a table and not as individual entries. |
| OCT smHardwareVpdWwnGuid | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.16 | OCTET STRING | read-only | Switch module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries. |
| OCT smHardwareVpdWwnGuidType | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.17 | OCTET STRING | read-only | The WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual entries. |
| INT smHealthState | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.15 | INTEGER | read-only | The health state for the switch module. 0 = unknown, 1 = good, 2 = warning, 3 = bad. |
| OCT smIOCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.18 | OCTET STRING | read-only | The compatibility status for the I/O module. The possible values and their meanings are as follows: Unknown: This indicates a communication error for the I/O module. OK: This is the normal (good) case where there are no compatibility issues between the I/O module and the modules it is internally wired to. No Fabric: This means the other end is not populated on any of the modules this I/O module is internally wired to (e.g. this is an Infiniband switch but none of the blades it is internally wired to has an expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following cases: One or more of the modules this I/O module is internally wired to is in communication error The I/O module is powered off and at least one module it is internally wired to is powered on Mismatch: Indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on a module the I/O module is internally wired to. |
| smIOCompatibilityEntry | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1 | not-accessible | Switch module IO compatibility table entry | |
| INT smIOCompatibilityId | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.2 | INTEGER | read-only | The switch module numeric identifier. |
| INT smIOCompatibilityIndex | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.1 | INTEGER | read-only | Switch module IO compatibility index. |
| OCT smIOCompatibilityModuleBay | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.3 | OCTET STRING | read-only | The modules (identified by an id string) that this I/O module can communicate with over the midplane networking fabric (i.e. a physical path exists between the I/O module and this module). |
| OCT smIOCompatibilityModuleFabricType | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.5 | OCTET STRING | read-only | The I/O fabric type on the module side for the module. 'n/a' will be displayed if the corresponding channel is not populated on the module side (e.g. we are looking at the details for an Infiniband switch but the blade does not have an Infiniband expansion card attached in the corresponding expansion slot). |
| OCT smIOCompatibilityModulePower | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.4 | OCTET STRING | read-only | The power state of the module specified in smIOCompatibilityModuleBay. |
| OCT smIOCompatibilityStatus | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.6 | OCTET STRING | read-only | The compatibility status for this I/O module and the module specified in smIOCompatibilityModuleBay. The possible values are: OK: No compatibility issues n/a: Indicates the corresponding channel is not populated on the module side even though the module is present (e.g. we are looking at the details for an Infiniband switch but the blade specified in smIOCompatibilityModuleBay does not have an Infiniband expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following: The module specified in smIOCompatibilityModuleBay has a communication error. The I/O module is powered off but the module specified in smIOCompatibilityModuleBay is powered on. Mismatch: Indicates one of the following cases:: Fabric types are incompatible Unknown fabric type on the module side Unknown I/O module type |
| smIOCompatibilityTable | 1.3.6.1.4.1.2.3.51.2.22.3.1.10 | not-accessible | Switch module control table. | |
| OCT smIOCompatibilityTargetTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.7 | OCTET STRING | read-only | The unique identifier for a component which communicates with this IO module. This is the same component identified with an id string in the smIOCompatibilityModuleBay column. The installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module |
| IP smIPAddress | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.6 | IpAddress | read-only | The switch module current IP address. If the switch module is participating in the Stacking Mode and IP Configuration is protected, then the stack management IP address is displayed. NOTE: IPv6 addresses for the switch can be view with the smIPv6AddressTable. |
| ADR smIPv6Address | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.4 | InetAddressIPv6 | read-only | The assigned IPv6 address |
| ADR smIPv6AddressDefaultRoute | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.6 | InetAddressIPv6 | read-only | The default route used for the given address |
| smIPv6AddressEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1 | not-accessible | The assigned IPv6 address for a given switch module NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | |
| INT smIPv6AddressEntryIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.2 | INTEGER | read-only | The switch module's address entry index |
| INT smIPv6AddressIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.1 | INTEGER | read-only | The switch module's slot number |
| INT smIPv6AddressPrefixLen | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.5 | INTEGER | read-only | The prefix length for the given address. |
| smIPv6AddressTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2 | not-accessible | A table of assigned IPv6 addresses for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | |
| INT smIPv6AddressType | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.3 | INTEGER | read-only | The address type. |
| INT smIPv6ConfigEnabled | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.2 | INTEGER | read-write | Enables/Disables IPv6 support on the switch module. |
| smIPv6ConfigEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1 | not-accessible | IPv6 configuration options for a switch module.. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | |
| INT smIPv6ConfigIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.1 | INTEGER | read-only | The switch module's slot number |
| INT smIPv6ConfigStatelessEnabled | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.5 | INTEGER | read-write | Enables/Disables IPv6 stateless auto-configuration support on the switch module. |
| INT smIPv6ConfigStatic | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.3 | INTEGER | read-write | Enables/Disables IPv6 static configuration support on the switch module. |
| smIPv6ConfigTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1 | not-accessible | A table of IPv6 configuration options for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | |
| ADR smIPv6StaticAddress | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.2 | InetAddressIPv6 | read-write | The assigned IPv6 address. NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting. |
| ADR smIPv6StaticAddressDefaultRoute | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.4 | InetAddressIPv6 | read-write | The default route used for the given address NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddress sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting. |
| INT smIPv6StaticAddressPrefixLen | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.3 | INTEGER | read-write | The prefix length for the given address. NOTE: If changing with smIPv6StaticAddress and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting. |
| smIPv6StaticConfigEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1 | not-accessible | The static IP address assignment information for an IO module. Once the assignement has taken place the address will show up as a row in the smIPv6AddressTable NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | |
| smIPv6StaticConfigTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3 | not-accessible | Allows configuration of static IPv6 information for supported IO modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | |
| INT smIPv6StaticIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.1 | INTEGER | read-only | The switch module's slot number |
| smLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.4 | |||
| smLEDsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.4.2.1 | not-accessible | Switch module LEDs information entry | |
| smLEDsTable | 1.3.6.1.4.1.2.3.51.2.2.8.4.2 | not-accessible | Table of switch module LEDs information. | |
| OCT smMACAddress | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.5 | OCTET STRING | read-only | Switch module MAC address. For IOMs which are members of a stack, this field is not applicable and should be disregarded. |
| OCT smMainApp1VpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.6 | OCTET STRING | read-only | Switch module firmware build date. |
| OCT smMainApp1VpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.5 | OCTET STRING | read-only | Switch module firmware build id. |
| OCT smMainApp1VpdRevisionNumber | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.7 | OCTET STRING | read-only | Switch module firmware revision number. |
| OCT smMainApp2VpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.9 | OCTET STRING | read-only | Switch module firmware build date. |
| OCT smMainApp2VpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.8 | OCTET STRING | read-only | Switch module firmware build id. |
| OCT smMainApp2VpdRevisionNumber | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.10 | OCTET STRING | read-only | Switch module firmware revision number. |
| OCT smMainApp3VpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.12 | OCTET STRING | read-only | I/O Module firmware build date. |
| OCT smMainApp3VpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.11 | OCTET STRING | read-only | I/O Module firmware build id. |
| OCT smMainApp3VpdRevisionNumber | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.13 | OCTET STRING | read-only | I/O Module firmware revision number. |
| smMainAppVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1 | not-accessible | Switch module main application VPD table entry | |
| INT smMainAppVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.3 | INTEGER | read-only | Indicates whether the switch module specified exists or not. |
| INT smMainAppVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.2 | INTEGER | read-only | The switch module numeric identifier. |
| INT smMainAppVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.1 | INTEGER | read-only | Switch module main application VPD entry index. |
| INT smMainAppVpdSwitchSubType | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.20 | INTEGER | read-only | Indicates the subtype of switch module installed. |
| INT smMainAppVpdSwitchType | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.4 | INTEGER | read-only | Indicates the type of switch module installed. |
| smMainAppVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.7.1 | not-accessible | Switch module main application VPD information table. | |
| OCT smManufacturingID | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.22 | OCTET STRING | read-only | Switch module hardware VPD manufacturing ID. |
| IP smNewGateway | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.8 | IpAddress | read-write | The switch module new IP gateway. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. |
| IP smNewIPAddr | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.6 | IpAddress | read-write | The switch module new IP address. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. |
| INT smNewIPConfigEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.10 | INTEGER | read-write | A set command enables a new IP configuration that has been previously defined. A get command indicates whether the new IP configuration information has been enabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. |
| INT smNewIPConfigMethod | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.9 | INTEGER | read-write | The switch module new IP configuration method. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. |
| smNewIPInfoEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1 | not-accessible | Switch module new IP configuration information table entry. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | |
| INT smNewIPInfoExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.3 | INTEGER | read-only | Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. |
| INT smNewIPInfoId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.2 | INTEGER | read-only | The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. |
| INT smNewIPInfoIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.1 | INTEGER | read-only | Switch module new IP info index. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. |
| INT smNewIPInfoPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.4 | INTEGER | read-only | Indicates whether the switch module specified is powered on or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.. |
| smNewIPInfoTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1 | not-accessible | Switch module new IP information. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | |
| IP smNewSubnetMask | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.7 | IpAddress | read-write | The switch module new subnet mask. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. |
| OCT smOnePortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.8 | OCTET STRING | read-only | Available speed setting per port for Switch Module 1. If there is more than one setting, the speeds are separated by a comma and then a space. |
| INT smOnePortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.12 | INTEGER | read-only | The length (in meters) of the cable supported by this port for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports. |
| OCT smOnePortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.13 | OCTET STRING | read-only | External cable type for this port, for example, active copper or passive fiber. |
| INT smOnePortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.15 | INTEGER | read-only | Compatibility of the external cable that is plugged into the port. |
| INT smOnePortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.16 | INTEGER | read-only | Data rate supported for this port. |
| smOnePortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1 | not-accessible | Switch Module 1 port configuration information table entry | |
| INT smOnePortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.1 | INTEGER | read-only | Switch Module 1 port sequence index. |
| OCT smOnePortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.2 | OCTET STRING | read-only | Switch Module 1 port label |
| INT smOnePortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.4 | INTEGER | read-write | Current port link setting for Switch Module 1. |
| INT smOnePortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.5 | INTEGER | read-only | Current port link state of Switch Module 1. |
| INT smOnePortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.9 | INTEGER | read-only | Port media type of Switch Module 1. |
| INT smOnePortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.10 | INTEGER | read-only | Port protocol of Switch Module 1. |
| OCT smOnePortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.6 | OCTET STRING | read-write | Set the port speed using the data rate and duplex value. For examples: 100mh: 100 Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smOnePortCfgAvailSpeeds object are applicable to setting this mib object. |
| OCT smOnePortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.7 | OCTET STRING | read-only | Current port speed of Switch Module 1. |
| smOnePortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1 | not-accessible | Switch Module 1 port configuration information. NOTE: This option is not supported on all I/O modules. | |
| INT smOnePortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.3 | INTEGER | read-only | Switch Module 1 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. |
| OCT smOnePortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.14 | OCTET STRING | read-only | The cable manufacturer. |
| INT smOnePortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.11 | INTEGER | read-only | The width of the port in terms of how many combined cables are present for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. |
| OCT smPingAddress | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.3 | OCTET STRING | read-only | The switch module's IPv4 or IPv6 address |
| INT smPingAddressEntryIndex | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.2 | INTEGER | read-only | The switch module's address entry index |
| INT smPingAddressExecute | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.4 | INTEGER | read-write | Pings the given IP address. NOTE: The GET operation for this object is meaningless. |
| smPingEntry | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1 | not-accessible | Represents a single address that can be pinged | |
| INT smPingIndex | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.1 | INTEGER | read-only | The switch module's slot number |
| smPingTable | 1.3.6.1.4.1.2.3.51.2.22.3.1.2 | not-accessible | Allows pinging one of the active assigned addresses of an I/O module. NOTE: This table is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | |
| INT smPMCtrlEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.17 | INTEGER | read-write | MM Protected Mode permission for the switch module. disabled - allow MM to disable Protected Mode Permission for the switch module. enabled - allow MM to grant Protected Mode Permission for the switch module. |
| INT smPMState | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.16 | INTEGER | read-only | The Protected Mode Status for the switch module. standby- Protected Mode capability exists on the IOM but has not been activated on the switch module or the MM. pending - Protected Mode has been activated on the MM but not yet on the switch module. active - Protected Mode is active on both the switch module and the MM. attention - Protected Mode is enabled on the switch module but not on the MM. |
| INT smPostResultsAvailable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.3 | INTEGER | read-only | Describes whether the switch module POST diagnostic result value contained in the smPostResultsValue is valid. |
| OCT smPostResultsValue | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.4 | OCTET STRING | read-only | The range of values and meanings are as follows: 0x00 - 0x7F ( 0 - 127) Base internal functions 0x80 - 0x9F (128 - 159) Internal interface failures 0xA0 - 0xAF (160 - 175) External interface failures 0xB0 - 0xFE (176 - 254) Reserved 0xFF (255) Switch completed POST successfully |
| INT smPowerOnRestartDelay | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.15 | INTEGER | read-write | Restart delay (in seconds) when power is applied to a switch module. |
| smPowerRestartEntry | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1 | not-accessible | Switch module power restart table entry | |
| INT smPowerRestartId | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.2 | INTEGER | read-only | The switch module numeric identifier. |
| INT smPowerRestartIndex | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.1 | INTEGER | read-only | Switch module power restart index. |
| smPowerRestartTable | 1.3.6.1.4.1.2.3.51.2.22.3.1.7 | not-accessible | Switch module power restart table. | |
| INT smPowerServiceResetCmd | 1.3.6.1.4.1.2.3.51.2.23.10.2.1.4 | INTEGER | read-write | To reset the auxiliary power on a switch component, set this object to resetVirtualReseatOperation(1). This will toggle the auxiliary power to the switch and simulate a physical removal and insertion. During the operation, auxiliary power is removed from the component and is then restored. For IOMs, the power state will be on after the operation completes. To perform a hard restart on the switch component, set this object to resetHardRestartOperation(2). This will toggle the reset line to the service processor causing it to re-initialize. The service processor on the component is directly reset, but the power state of the component will not be affected by this operation. This object is intended to be write-only. The component will experience a temporary loss of communication and the power state will change. Prior to executing this action, perform any operations needed to protect user data. Reading this object will always return the value of noOperation(0). |
| smPowerServiceResetEntry | 1.3.6.1.4.1.2.3.51.2.23.10.2.1 | not-accessible | Switch module power service reset entry | |
| INT smPowerServiceResetIndex | 1.3.6.1.4.1.2.3.51.2.23.10.2.1.1 | INTEGER | read-only | Switch module power service reset index. |
| INT smPowerServiceResetStatus | 1.3.6.1.4.1.2.3.51.2.23.10.2.1.3 | INTEGER | read-only | Status of the aux power power. A value of auxPowerOff(0) indicates that the switch aux power is off. A value of auxPowerOn(1) indicates that the switch aux power is on. |
| INT smPowerServiceResetSwitchId | 1.3.6.1.4.1.2.3.51.2.23.10.2.1.2 | INTEGER | read-only | The switch module numeric identifier. |
| smPowerServiceResetTable | 1.3.6.1.4.1.2.3.51.2.23.10.2 | not-accessible | A table providing aux power status and the ability to perform a virtual reseat or hard restart of a switch. | |
| INT smReset | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.8 | INTEGER | read-write | For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. This MIB object can not be set, if MM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT smResetToDefault | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.9 | INTEGER | read-write | For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. In both cases, the switch module will reset the configuration to the default values. This MIB object can not be set, if MM grants switch module the Protected Mode permission and switch module goes into Protected Mode. This MIB object can not be set, if the switch module is participating in the Stacking Mode and reset to default is protected. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT smRestartAndRunExtDiag | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.11 | INTEGER | read-write | To power cycle the selected module(s) and then run the extended diagnostic test package. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT smRestartAndRunFullDiag | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12 | INTEGER | read-write | To power cycle the selected module(s) and then run the full diagnostic test package. The full diagnostic test package may take over 5 minutes to run. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT smRestartAndRunStdDiag | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.10 | INTEGER | read-write | To power cycle the selected module(s) and then run the standard diagnostic test package. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| OCT smStackingModeInfo | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.24 | OCTET STRING | read-only | A string containing a text description about the details of which functions are protected for a switch module when it is in Stacking Mode as Master or Member. The possible functions protected by switch modules are IP configuration, External Port Access, External Management all over ports and Restore to defaults. |
| INT smStackingModeState | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.23 | INTEGER | read-only | The Stacking Mode Status for the switch module. standby - I/O module has stacking capability but is not part of a stack. member - I/O module has stacking capability and is part of a stack in the member role. master - I/O module has stacking capability and is part of a stack in the master role. NOTE: The term disabled was changed to the term standby to be more descriptive. |
| INT smSwitchExists | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.3 | INTEGER | read-only | Indicates whether the switch module specified exists or not. |
| INT smSwitchWidth | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.21 | INTEGER | read-only | Switch module width. |
| OCT smThreePortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.8 | OCTET STRING | read-only | Available speed setting per port for Switch Module 3. If there is more than one setting, the speeds are separated by a comma and then a space. |
| INT smThreePortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.12 | INTEGER | read-only | The length (in meters) of the cable supported by this port for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports. |
| OCT smThreePortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.13 | OCTET STRING | read-only | External cable type for this port, for example, active copper or passive fiber. |
| INT smThreePortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.15 | INTEGER | read-only | Compatibility of the external cable that is plugged into the port. |
| INT smThreePortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.16 | INTEGER | read-only | Data rate supported for this port. |
| smThreePortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1 | not-accessible | Switch Module 3 port configuration information table entry | |
| INT smThreePortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.1 | INTEGER | read-only | Switch Module 3 port sequence index. |
| OCT smThreePortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.2 | OCTET STRING | read-only | Switch Module 3 port label |
| INT smThreePortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.4 | INTEGER | read-write | Current port link setting for Switch Module 3. |
| INT smThreePortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.5 | INTEGER | read-only | Current port link state of Switch Module 3. |
| INT smThreePortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.9 | INTEGER | read-only | Port media type of Switch Module 3. |
| INT smThreePortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.10 | INTEGER | read-only | Port protocol of Switch Module 3. |
| OCT smThreePortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.6 | OCTET STRING | read-write | Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smThreePortCfgAvailSpeeds are applicable to setting this mib object. |
| OCT smThreePortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.7 | OCTET STRING | read-only | Current port speed of Switch Module 3. |
| smThreePortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1 | not-accessible | Switch Module 3 port configuration information. Note: This option is not supported on all I/O modules. | |
| INT smThreePortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.3 | INTEGER | read-only | Switch Module 3 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. |
| OCT smThreePortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.14 | OCTET STRING | read-only | The cable manufacturer. |
| INT smThreePortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.11 | INTEGER | read-only | The width of the port in terms of how many combined cables are present for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. |
| smtpConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.3 | |||
| OCT smtpEmailDomain | 1.3.6.1.4.1.2.3.51.2.4.9.3.3.3 | OCTET STRING | read-write | A NULL terminated string that contains the SMTP email domain. If this field is empty, the MM IP address is used as the domain. However, some SMTP servers (e.g. - MS Exchange 2007) do not accept an IP address and instead require a domain name. This object can be used to set that email domain name. |
| OCT smtpServerNameOrIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.3.1 | OCTET STRING | read-write | A NULL terminated 64 byte string that contains the SMTP server host name or IP address (a.b.c.d). |
| OCT smTwoPortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.8 | OCTET STRING | read-only | Available speed setting per port for Switch Module 2. If there is more than one setting, the speeds are separated by a comma and then a space. |
| INT smTwoPortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.12 | INTEGER | read-only | The length (in meters) of the cable supported by this port for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports. |
| OCT smTwoPortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.13 | OCTET STRING | read-only | External cable type for this port, for example, active copper or passive fiber. |
| INT smTwoPortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.15 | INTEGER | read-only | Compatibility of the external cable that is plugged into the port. |
| INT smTwoPortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.16 | INTEGER | read-only | Data rate supported for this port. |
| smTwoPortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1 | not-accessible | Switch Module 2 port configuration information table entry | |
| INT smTwoPortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.1 | INTEGER | read-only | Switch Module 2 port sequence index. |
| OCT smTwoPortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.2 | OCTET STRING | read-only | Switch Module 2 port label |
| INT smTwoPortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.4 | INTEGER | read-write | Current port link setting for Switch Module 2. |
| INT smTwoPortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.5 | INTEGER | read-only | Current port link state of Switch Module 2. |
| INT smTwoPortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.9 | INTEGER | read-only | Port media type of Switch Module 2. |
| INT smTwoPortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.10 | INTEGER | read-only | Port protocol of Switch Module 2. |
| OCT smTwoPortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.6 | OCTET STRING | read-write | Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smTwoPortCfgAvailSpeeds are applicable to setting this mib object. |
| OCT smTwoPortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.7 | OCTET STRING | read-only | Current port speed of Switch Module 2. |
| smTwoPortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1 | not-accessible | Switch Module 2 port configuration information. Note: This option is not supported on all I/O modules. | |
| INT smTwoPortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.3 | INTEGER | read-only | Switch Module 2 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. |
| OCT smTwoPortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.14 | OCTET STRING | read-only | The cable manufacturer. |
| INT smTwoPortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.11 | INTEGER | read-only | The width of the port in terms of how many combined cables are present for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. |
| INT snmp | 1.3.6.1.4.1.2.3.51.2.4.1.5.2 | INTEGER | read-write | Enable/Disable SNMP v1 and v3 access to the MM. The value enabled(3) means both telnet and ssh are enabled. |
| snmpAgentCommunityConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4 | |||
| snmpAgentConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.1 | |||
| INT snmpAgentPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.6 | INTEGER | read-write | SNMP Agent port number. Default value is 161. Changes take effect after several seconds. |
| snmpAgentUserProfileConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9 | |||
| snmpCommunityEntry | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1 | not-accessible | SNMP community entries | |
| OCT snmpCommunityEntryCommunityIpAddress1 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.3 | OCTET STRING | read-write | SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address |
| OCT snmpCommunityEntryCommunityIpAddress2 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.4 | OCTET STRING | read-write | SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address |
| OCT snmpCommunityEntryCommunityIpAddress3 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.5 | OCTET STRING | read-write | SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address |
| OCT snmpCommunityEntryCommunityName | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.2 | OCTET STRING | read-write | SNMP Community entry name. |
| INT snmpCommunityEntryCommunityViewType | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.6 | INTEGER | read-write | Access Level of the SNMPv1 managers. Note this parameter is set for each community. Therefore all three managers in the same community have the same access level. |
| INT snmpCommunityEntryIndex | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.1 | INTEGER | read-only | Index for SNMP Agent Community entry. |
| snmpCommunityTable | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1 | not-accessible | Table of SNMP Community entries | |
| INT snmpSystemAgentTrapsDisable | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.3 | INTEGER | read-write | Disable or enable SNMP traps. |
| OCT snmpSystemContact | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.1 | OCTET STRING | read-write | A NULL terminated 48 byte string that contains the SNMP agent contact name. |
| OCT snmpSystemLocation | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.2 | OCTET STRING | read-write | A NULL terminated 48 byte string that contains the SNMP agent location name. |
| INT snmpTrapsPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.7 | INTEGER | read-write | SNMP Traps port number. Default value is 162. Changes take effect after several seconds. |
| snmpUserProfileEntry | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1 | not-accessible | SNMP User Profile entries | |
| INT snmpUserProfileEntryAuthProt | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.4 | INTEGER | read-write | SNMPv3 User Profile entry - Authentication Protocol supported by the user. |
| OCT snmpUserProfileEntryContextName | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.3 | OCTET STRING | read-write | SNMPv3 User Profile entry - Context name for users to access MIB objects. Note that context names can be duplicates and can be shared among users. Empty context names are allowed. The default context name is the empty string. |
| INT snmpUserProfileEntryIndex | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.1 | INTEGER | read-only | Index for SNMPv3 Agent User Profile entry. |
| OCT snmpUserProfileEntryIpAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.9 | OCTET STRING | read-write | SNMPv3 User Profile entry - IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. |
| OCT snmpUserProfileEntryPrivPassword | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.7 | OCTET STRING | read-write | SNMPv3 User Profile entry - Privacy password for the user. NOTE: Value returned for the GET command is meaningless for this MIB object for security reasons. |
| INT snmpUserProfileEntryPrivProt | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.6 | INTEGER | read-write | SNMPv3 User Profile entry - Privacy Protocol supported by the user. The Privacy Password must be set and the Authentication Protocol must be md5 or sha before this field may be set to des or aes. |
| OCT snmpUserProfileEntryUserId | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.10 | OCTET STRING | read-only | The userid for the SNMPv3 Agent User Profile entry. |
| INT snmpUserProfileEntryViewType | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.8 | INTEGER | read-write | SNMPv3 User Profile entry - Access level (Get, Set, and Traps) of the user. |
| snmpUserProfileTable | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1 | not-accessible | Table of SNMPv3 User Profile entries | |
| INT snmpv1SystemAgentEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.5 | INTEGER | read-write | Disable or enable the SNMPv1 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv1 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact (2) Is there a valid system name (3) Is there at least one valid community name and for that community name is there one valid IP address or hostname (4) Are all defined community names unique If this verification fails an error response will be returned and the SNMPv1 agent will be left disabled. |
| INT snmpv3SystemAgentEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.6 | INTEGER | read-write | Disable or enable the SNMPv3 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv3 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact? (2) Is there a valid system name? If this verification fails an error response will be returned and the SNMPv3 agent will be left disabled. |
| INT solAccumulateTimeout | 1.3.6.1.4.1.2.3.51.2.4.10.1.3 | INTEGER | read-write | This value specifies how much time in millisecond SOL to buffer data before sending the next SOL packet since the last SOL packet was transmitted. Valid value from 5 ms to 1275 ms. The value is in 5 ms increment. Value is not in 5 ms increment will be truncated to a nearest 5s. Default value is 5 ms. |
| INT solBladeBytesReceived | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.11 | INTEGER | read-only | Number of bytes received. |
| INT solBladeBytesSent | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.10 | INTEGER | read-only | Number of bytes sent. |
| INT solBladeCapability | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.6 | INTEGER | read-only | Display whether or not the blade support SOL feature. |
| solBladeConfig | 1.3.6.1.4.1.2.3.51.2.4.10.2 | |||
| OCT solBladeConsoleLoginEnd | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.16 | OCTET STRING | read-only | The time that SOL console ends. |
| OCT solBladeConsoleLoginFrom | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.14 | OCTET STRING | read-only | The location information from where the SOL console is logged in. |
| OCT solBladeConsoleLoginStart | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.15 | OCTET STRING | read-only | The time that SOL console starts. |
| OCT solBladeConsoleUserId | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.13 | OCTET STRING | read-only | Sol console user name. |
| OCT solBladeDestinationMAC | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.12 | OCTET STRING | read-only | MAC address of the blade. |
| INT solBladeEnable | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.3 | INTEGER | read-write | Disable or enable a SOL on a blade. |
| solBladeEntry | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1 | not-accessible | SOL Blade table entry | |
| INT solBladeIndex | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.1 | INTEGER | read-only | SOL Blade table index. |
| IP solBladeIpAddr | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.4 | IpAddress | read-only | This is deprecated in favor of solBladeIpAddr6. IP address of the blade derived from the IP address range for the blade system management processors on the blades. NOTE: The IPv6 address for a blade can be view with the bladeIPv6AddressTable. |
| ADR solBladeIpAddr6 | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.7 | InetAddressIPv6 | read-only | IPv6 address of the blade. |
| OCT solBladeName | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.2 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| INT solBladeRetryCount | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.9 | INTEGER | read-only | Retry count. |
| INT solBladeRetryInterval | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.8 | INTEGER | read-only | Retry interval time in miliseconds. |
| INT solBladeSessionStatus | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.5 | INTEGER | read-only | Status of a blade SOL session: solSessionNotReady: no SOL session connected to the blade. solSessionReady: there is an SOL session to the blade. solSessionActive: there is an SOL session to the blade and there is a client using the SOL session. |
| solBladeTable | 1.3.6.1.4.1.2.3.51.2.4.10.2.1 | not-accessible | SOL Blade configuration table. | |
| INT solCharSendThreshold | 1.3.6.1.4.1.2.3.51.2.4.10.1.4 | INTEGER | read-write | This value specifies how many characters SOL to buffer before sending the next SOL packet since the last SOL packet was transmitted. Valid value is from 1 to 251 |
| solConfiguration | 1.3.6.1.4.1.2.3.51.2.4.10 | |||
| INT solEnable | 1.3.6.1.4.1.2.3.51.2.4.10.1.1 | INTEGER | read-write | Disable/Enable SOL dynamically. |
| OCT solExitToCliKeySeq | 1.3.6.1.4.1.2.3.51.2.4.10.1.7 | OCTET STRING | read-write | This is the keystroke sequence used to escape out of SOL session and back to CLI console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[(' i.e. ESC followed by (. |
| solGlobalConfig | 1.3.6.1.4.1.2.3.51.2.4.10.1 | |||
| OCT solResetBladeKeySeq | 1.3.6.1.4.1.2.3.51.2.4.10.1.8 | OCTET STRING | read-write | This is the keystroke sequence used to reset the blade while in SOL session console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[R^[r^[R' i.e. ESC R ESC r ESC R. |
| INT solRetry | 1.3.6.1.4.1.2.3.51.2.4.10.1.5 | INTEGER | read-write | Retry count. Valid value from 0-7. 0 means no retries after packet is transmitted. Packet will be dropped if no ACK/NACK received by the time retries expired. |
| INT solRetryInterval | 1.3.6.1.4.1.2.3.51.2.4.10.1.6 | INTEGER | read-write | Retry Interval in 10 ms increment. Sets the time that the SOL will wait before the first retry and the time between retries when sending SOL packets to the remote blade. Value range is from 0 to 2550 ms in 10 ms increment. 0 means retries will be sent back-to-back. |
| spClock | 1.3.6.1.4.1.2.3.51.2.4.4 | |||
| OCT spClockDateAndTimeSetting | 1.3.6.1.4.1.2.3.51.2.4.4.1 | OCTET STRING | read-write | MM clock date and time setting. A date-time specification for the local time of day. For example to set the date and time to March 4, 2001 at 06:00:00AM, set the value to:'03/04/2001,06:00:00'. field contents range _____ ________ _____ 1 month 01..12 2 separator '/' 3 day 01..31 4 separator '/' 5 year 2000..2089 6 separator ',' 7 hour 00..23 8 separator ':' 9 minutes 00..59 10 separator ':' 11 seconds 00..59 |
| OCT spClockTimezoneCaption | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.3 | OCTET STRING | read-only | Time zone caption. |
| INT spClockTimezoneCmmOffset | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.10 | INTEGER | read-only | CMM offset. |
| OCT spClockTimezoneDaylightCaption | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.9 | OCTET STRING | read-only | Time zone daylight caption. |
| INT spClockTimezoneDaylightDay | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.13 | INTEGER | read-only | There are two different interpretations for this field, depending on the value of DaylightDayOfWeek. In one case, DaylightDay defines the day-in-month on which daylight saving time starts. This interpretation is used when the DaylightDayOfWeek is 0. A positive or negative integer is specified to indicate whether the DaylightDay is calculated from the beginning or the end of the month. For example, 5 indicates the fifth day in the DaylightMonth and -1 indicates the last day in the DaylightMonth. When DaylightDayOfWeek is not 0, DaylightDay is the day in the month on which daylight saving time starts, as defined in conjunction with DaylightDayOfWeek. For example, if DaylightDay is 15 and DaylightDayOfWeek is Saturday, then daylight saving time starts on the first Saturday on or after the 15th day in the DaylightMonth (that is, the third Saturday in the month). If DaylightDay is 20 and DaylightDayOfWeek is -Saturday, then this indicates the first Saturday on or before the 20th day in the DaylightMonth. If DaylightDay is -1 and DaylightDayOfWeek is -Sunday, then this indicates the last Sunday in the month. |
| INT spClockTimezoneDaylightDayOfWeek | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.14 | INTEGER | read-only | Day of week daylight saving begins. |
| OCT spClockTimezoneDaylightEnd | 1.3.6.1.4.1.2.3.51.2.4.4.6 | OCTET STRING | read-only | DST end. |
| INT spClockTimezoneDaylightIntervalInMinutes | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.19 | INTEGER | read-only | Interval in minutes (Daylight saving begins). |
| INT spClockTimezoneDaylightMonth | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.15 | INTEGER | read-only | Month daylight saving begins. |
| OCT spClockTimezoneDaylightName | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.8 | OCTET STRING | read-only | Time zone daylight name. |
| INT spClockTimezoneDaylightStandardDay | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.16 | INTEGER | read-only | There are two different interpretations for this property, depending on the value of StandardDayOfWeek. In one case, StandardDay defines the day-in-month on which daylight saving time ends. This interpretation is used when the StandardDayOfWeek is 0. A positive or negative integer is specified to indicate whether the StandardDay is calculated from the beginning or the end of the month. For example, 5 indicates the fifth day in the StandardMonth and -1 indicates the last day in the StandardMonth. When StandardDayOfWeek is not 0, StandardDay is the day-in-month on which daylight saving time ends, as defined in conjunction with StandardDayOfWeek. For example, if StandardDay is 15 and StandardDayOfWeek is Saturday, then daylight saving time ends on the first Saturday on or after the 15th day in the StandardMonth (that is, the third Saturday in the month). If StandardDay is 20 and StandardDayOfWeek is -Saturday, then this indicates the first Saturday on or before the 20 th day in the StandardMonth. If StandardDay is -1 and StandardDayOfWeek is -Sunday, then this indicates the last Sunday in the StandardMonth. |
| INT spClockTimezoneDaylightStandardDayOfWeek | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.17 | INTEGER | read-only | Day of week daylight saving ends. |
| INT spClockTimezoneDaylightStandardInMinutes | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.20 | INTEGER | read-only | Interval in minutes (Daylight saving ends). |
| INT spClockTimezoneDaylightStandardMonth | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.18 | INTEGER | read-only | Month daylight saving ends. |
| OCT spClockTimezoneDaylightStart | 1.3.6.1.4.1.2.3.51.2.4.4.5 | OCTET STRING | read-only | DST start. |
| OCT spClockTimezoneDescription | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.4 | OCTET STRING | read-only | Time zone description. |
| spClockTimezoneEntry | 1.3.6.1.4.1.2.3.51.2.4.4.3.1 | not-accessible | Time zone entry | |
| OCT spClockTimezoneId | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.2 | OCTET STRING | read-only | Time zone instance id. |
| INT spClockTimezoneIndex | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.1 | INTEGER | read-only | Time zone table index. |
| OCT spClockTimezoneName | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.5 | OCTET STRING | read-only | Time zone name. |
| OCT spClockTimezoneSetting | 1.3.6.1.4.1.2.3.51.2.4.4.2 | OCTET STRING | read-write | MM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST) settings. For write, the value must be a time zone listed in spClockTimezoneTable. The spClockTimezoneTable lists all valid time zones. Example: To set America's New York time zone, set the value to: 'America/New_York' For read, the value format is ,, () Example: -4:00,yes,America/New_York (Eastern Time) |
| OCT spClockTimezoneStandardCaption | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.7 | OCTET STRING | read-only | Time zone standard caption. |
| INT spClockTimezoneStandardDaylightOffsetMinutes | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.12 | INTEGER | read-only | Standard GMT offset in minutes. |
| OCT spClockTimezoneStandardName | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.6 | OCTET STRING | read-only | Time zone standard name. |
| INT spClockTimezoneStandardOffsetMinutes | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.11 | INTEGER | read-only | Standard GMT offset in minutes. |
| spClockTimezoneTable | 1.3.6.1.4.1.2.3.51.2.4.4.3 | not-accessible | Table of all time zones listed in zone.tab file | |
| INT spEthOverUSBInterfaceBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.3 | INTEGER | read-only | Indicates whether the blade specified exists or not. |
| OCT spEthOverUSBInterfaceBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.2 | OCTET STRING | read-only | The numeric blade ID. |
| OCT spEthOverUSBInterfaceBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.6 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| INT spEthOverUSBInterfaceEnable | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.9 | INTEGER | read-write | This object allows the user to view the status of, and enable or disable, a blade Service Processor's command interface on Ethernet-over-USB. NOTE: If the blade either does not exist or does not support Ethernet-over-USB command interface. It displays 'notApplicable'. NOTE: It will take about 10 or more seconds for the disable/enable setting to take effect. |
| spEthOverUSBInterfaceEntry | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1 | not-accessible | Blade Service Processor's Ethernet over USB interface entry. | |
| INT spEthOverUSBInterfaceIndex | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.1 | INTEGER | read-only | Service Processor's Ethernet over USB interface table index. |
| spEthOverUSBInterfaceTable | 1.3.6.1.4.1.2.3.51.2.22.1.14.1 | not-accessible | Table of blade Service Processor's Ethernet over USB interface. | |
| spIdentification | 1.3.6.1.4.1.2.3.51.2.4.5 | |||
| spStatus | 1.3.6.1.4.1.2.3.51.2.2.5 | |||
| OCT spTxtId | 1.3.6.1.4.1.2.3.51.2.4.5.1 | OCTET STRING | read-write | Text description of the MM. NOTE: Do not put any 'space characters' at end of the string. |
| INT sshEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.10 | INTEGER | read-write | Disable/Enable SSH. |
| INT sshPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.5 | INTEGER | read-write | SSH port number. Default value is 22. |
| INT sslClientEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.16 | INTEGER | read-write | Disable/Enable SSL Client. If no valid client or server certificate is in place, SSL client will not be allowed to set to enable. |
| INT sslServerEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.15 | INTEGER | read-write | Disable/Enable SSL Server. |
| IP standbyDhcpDHCPServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.6 | IpAddress | read-only | Contains the DHCP server IP address used to acquire the DHCP settings. NOTE: This MIB object is only applicable to systems with a standby MM. |
| OCT standbyDhcpDomainName | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.5 | OCTET STRING | read-only | Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. |
| standbyDhcpEthernetInterface | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16 | |||
| IP standbyDhcpGatewayIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.3 | IpAddress | read-only | Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. |
| OCT standbyDhcpHostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.1 | OCTET STRING | read-only | Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. |
| IP standbyDhcpIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.2 | IpAddress | read-only | Contains the IP address for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. |
| IP standbyDhcpPrimaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.7 | IpAddress | read-only | Contains the Primary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. |
| IP standbyDhcpSecondaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.8 | IpAddress | read-only | Contains the Secondary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. |
| IP standbyDhcpSubnetMask | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.4 | IpAddress | read-only | Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. |
| IP standbyDhcpTertiaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.9 | IpAddress | read-only | Contains the tertiary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. |
| OCT standbyDomainName | 1.3.6.1.4.1.2.3.51.2.4.9.1.14 | OCTET STRING | read-write | The user assigned DNS domain name of the standby. This is only applicable to systems with a standby MM. |
| standbyEthernetInterfaceDHCPv6Config | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3 | |||
| OCT standbyEthernetInterfaceDHCPv6DomainName | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.4 | OCTET STRING | read-only | The 64 byte Domain Name for the standby MM assigned by the DHCPv6 server. |
| INT standbyEthernetInterfaceDHCPv6Enabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.1 | INTEGER | read-only | The DHCPv6 enabled or disabled state for the standby MM. NOTE: This field may be altered through the extEthernetInterfaceDHCPv6Enabled object. |
| ADR standbyEthernetInterfaceDHCPv6IPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.2 | InetAddressIPv6 | read-only | The IPv6 address for the standby MM assigned by DHCPv6 server. |
| ADR standbyEthernetInterfaceIPv6LinkLocalAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.1.1 | InetAddressIPv6 | read-only | The IPv6 link local IP address for the standby MM. |
| standbyEthernetInterfaceIPv6LocalAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.1 | |||
| ADR standbyEthernetInterfaceIPv6StaticIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.2 | InetAddressIPv6 | read-write | The IPv6 static IP address for the standby MM NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. |
| INT standbyEthernetInterfaceIPv6StaticIPAddressPrefixLen | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.3 | INTEGER | read-only | The IPv6 static IP address prefix length for the standyby MM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPAddressPrefixLen object. |
| standbyEthernetInterfaceIPv6StaticIPConfig | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2 | |||
| INT standbyEthernetInterfaceIPv6StaticIPConfigEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.1 | INTEGER | read-only | The IPv6 static IP address state for the MM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPConfigEnabled object. |
| ADR standbyEthernetInterfaceIPv6StaticIPDefaultRoute | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.4 | InetAddressIPv6 | read-only | The IPv6 static IP address default route for the standby MM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPDefaultRoute object. |
| ADR standbyEthernetInterfaceStatelessAutoConfigAddresses | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.2 | InetAddressIPv6 | read-only | The stateless Auto-Configuration IPv6 address. |
| standbyEthernetInterfaceStatelessAutoConfigAddressesEntry | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1 | not-accessible | Stateless Auto-Config address entries | |
| INT standbyEthernetInterfaceStatelessAutoConfigAddressesIndex | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.1 | INTEGER | read-only | Index for stateless Auto-Config addresses. |
| INT standbyEthernetInterfaceStatelessAutoConfigAddressesPrefixLen | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.3 | INTEGER | read-only | The stateless Auto-Configration address prefix length. |
| standbyEthernetInterfaceStatelessAutoConfigAddressesTable | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4 | not-accessible | Table of stateless Auto-Config addresses entries. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this table will show nothing. | |
| standbyExtEthernetInterface | 1.3.6.1.4.1.2.3.51.2.4.9.1.3 | |||
| OCT standbyExtEthernetInterfaceBIA | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.10 | OCTET STRING | read-only | Specifies the burned-in MAC (BIA) address. NOTE: This MIB object is only applicable to systems with a standby MM. |
| INT standbyExtEthernetInterfaceDataRate | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.5 | INTEGER | read-write | Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G or Auto. NOTE: This MIB object is only applicable to systems with a standby MM. |
| INT standbyExtEthernetInterfaceDhcpEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.8 | INTEGER | read-write | Disable or enable DHCP on this interface. NOTE: This MIB object is only applicable to systems with a standby MM. |
| INT standbyExtEthernetInterfaceDuplexSetting | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.6 | INTEGER | read-write | Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This MIB object is only applicable to systems with a standby MM. |
| IP standbyExtEthernetInterfaceGatewayIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.9 | IpAddress | read-write | Contains the IP address of the gateway/router for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. |
| OCT standbyExtEthernetInterfaceHostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.3 | OCTET STRING | read-write | Contains the 64 byte null terminated DNS host name for this interface. NOTE: This MIB object is only applicable to systems with a standby MM. |
| IP standbyExtEthernetInterfaceIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.4 | IpAddress | read-write | Contains the IP address for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. |
| standbyExtEthernetInterfaceIPv6 | 1.3.6.1.4.1.2.3.51.2.4.9.1.5 | |||
| OCT standbyExtEthernetInterfaceLAA | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.7 | OCTET STRING | read-write | Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: This MIB object is only applicable to systems with a standby MM. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup MM, it is not recommended. |
| INT standbyExtEthernetInterfaceMTU | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.13 | INTEGER | read-write | Contains the Maximum Transmission Unit (MTU) for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. |
| IP standbyExtEthernetInterfaceSubnetMask | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.14 | IpAddress | read-write | Contains the subnet mask for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. |
| OCT standbyExtEthernetInterfaceType | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.1 | OCTET STRING | read-only | The type of interface. NOTE: This MIB object is only applicable to systems with a standby MM. |
| OCT standbyFirmwareUpdateStatus | 1.3.6.1.4.1.2.3.51.2.22.9.6 | OCTET STRING | read-only | Get the current status of the firmware update for the standby MM. NOTE: This only applies to systems with a standby MM. |
| OCT standbyHostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.12 | OCTET STRING | read-write | Contains the DNS host name for the standby. This object provides the exact same function as standbyExtEthernetInterfaceHostName and is only applicable to systems with a standby MM. |
| OCT state | 1.3.6.1.4.1.2.3.51.2.23.4.3.7 | OCTET STRING | read-write | The state of the machine location. 2-3 characters. |
| INT stcm | 1.3.6.1.4.1.2.3.51.2.4.1.5.5 | INTEGER | read-write | Enable/Disable secure TCP command mode (STCM) access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable. |
| switchCurrentNwCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1 | |||
| switchDetails | 1.3.6.1.4.1.2.3.51.2.2.10.4.2 | |||
| switchIPv6Config | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4 | |||
| switchMgmtNetworkCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.1 | |||
| switchModFourPortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4 | |||
| switchModOnePortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1 | |||
| switchModThreePortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3 | |||
| switchModTwoPortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2 | |||
| switchModule | 1.3.6.1.4.1.2.3.51.2.22.3 | |||
| switchModuleConfig | 1.3.6.1.4.1.2.3.51.2.22.3.2 | |||
| switchModuleControl | 1.3.6.1.4.1.2.3.51.2.22.3.1 | |||
| INT switchModuleControlId | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.2 | INTEGER | read-only | The switch module numeric identifier. |
| INT switchModuleMemDiagEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.5 | INTEGER | read-write | Switch module memory diagnostics enabled or disabled. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published. |
| INT switchModulePowerOnOff | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.7 | INTEGER | read-write | I/O Module power on or power off. If powering on a currently powered off I/O Module, then the I/O Module will execute a POST. The results of this POST will need to be retrieved using the 'Post Results' command. NOTE: When powering off a currently powered on I/O Module, a minimum of 1 second is needed to allow the module to power off before powering back on. The value 'shutdownInProgress' is for I/O Modules that may take some time to transition from 'poweron' to 'poweroff'. This MIB object can not be set, if MM grants the I/O Module the Protected Mode permission and module goes into Protected Mode. |
| switchNewNwCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2 | |||
| INT switchOverRedundantMM | 1.3.6.1.4.1.2.3.51.2.7.7 | INTEGER | read-write | Switch over to the redundant Management Module. The failover will not occur if the standby or primary MM is in flashing mode. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a redundant MM. |
| switchPortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2 | |||
| switchPowerTrending | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3 | |||
| INT switchPowerTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.1 | INTEGER | read-write | Specify time period for switch module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Switch Module. |
| OCT switchPowerTrendingSampleAve | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.6 | OCTET STRING | read-only | Switch Module Power Trending Sample Table Average Power. |
| switchPowerTrendingSampleEntry | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1 | not-accessible | Switch Module Power Trending Sample entry. | |
| INT switchPowerTrendingSampleId | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.2 | INTEGER | read-only | Switch Module Power Trending Sample Table Switch Id. |
| INT switchPowerTrendingSampleIndex | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.1 | INTEGER | read-only | Switch Module Power Trending Sample Table Index. |
| OCT switchPowerTrendingSampleMax | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.4 | OCTET STRING | read-only | Switch Module Power Trending Sample Table Maximum Power. |
| OCT switchPowerTrendingSampleMin | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.5 | OCTET STRING | read-only | Switch Module Power Trending Sample Table Minimum Power. |
| switchPowerTrendingSampleTable | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10 | not-accessible | Table of Switch Module Power Trending Information. | |
| OCT switchPowerTrendingSampleTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.3 | OCTET STRING | read-only | Switch Module Power Trending Sample Table Timestamp. |
| INT switchPowerTrendingSwitchId | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.2 | INTEGER | read-write | Switch Module Power Trending Switch Id. NOTE: The Switch Id should be configured before displaying the switchPowerTrendingTable. |
| syslogCollectorConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2 | |||
| INT syslogCollectorEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.4 | INTEGER | read-write | Syslog Collector enable/disable. |
| syslogCollectorEntry | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1 | not-accessible | Syslog Collector entries | |
| OCT syslogCollectorHostnameOrIpAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.2 | OCTET STRING | read-write | Syslog Collector IP address or host name. |
| INT syslogCollectorIndex | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.1 | INTEGER | read-only | Index for Syslog Collector entry. |
| INT syslogCollectorPort | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.3 | INTEGER | read-write | Syslog Collector port number. |
| syslogCollectorTable | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1 | not-accessible | Table of Syslog Collector entries | |
| syslogConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.9 | |||
| INT syslogSevFilterLevel | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.1 | INTEGER | read-write | syslogSevFilterLevel error/warning/information . |
| INT syslogTestPacket | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.3 | INTEGER | read-write | Generate a test syslog packet. This will send a test syslog to all configured and enabled syslog collectors to assist in validating the configuration. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| INT systemBlade | 1.3.6.1.4.1.2.3.51.2.4.2.3.16 | INTEGER | read-write | Generate an alert for any informational condition on a blade. |
| INT systemChassis | 1.3.6.1.4.1.2.3.51.2.4.2.3.20 | INTEGER | read-write | Generate an alert for any informational condition on chassis. |
| INT systemFan | 1.3.6.1.4.1.2.3.51.2.4.2.3.21 | INTEGER | read-write | Generate an alert for any informational condition on cooling device. |
| systemHealth | 1.3.6.1.4.1.2.3.51.2.2.7 | |||
| INT systemHealthStat | 1.3.6.1.4.1.2.3.51.2.2.7.1 | INTEGER | read-only | Indicates status of system health for the system in which the MM resides. Value of 'critical' indicates a severe error has occurred and the system may not be functioning. A value of 'nonCritical' indicates that a error has occurred but the system is currently functioning properly. A value of 'systemLevel' indicates that a condition has occurred that may change the state of the system in the future but currently the system is working properly. A value of 'normal' indicates that the system is operating normally. |
| OCT systemHealthSummaryAuxData | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.11 | OCTET STRING | read-only | System health summary auxilliary event data. If auxilliary event data is available, it is device-specific event data provided to the CMM by the device. |
| OCT systemHealthSummaryDateTime | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.4 | OCTET STRING | read-only | System health summary date time. |
| OCT systemHealthSummaryDescription | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.3 | OCTET STRING | read-only | System health summary description. |
| systemHealthSummaryEntry | 1.3.6.1.4.1.2.3.51.2.2.7.2.1 | not-accessible | System Health Summary entry | |
| OCT systemHealthSummaryEventID | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.12 | OCTET STRING | read-only | System health summary event ID. |
| INT systemHealthSummaryIndex | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.1 | INTEGER | read-only | System health summary index. |
| OCT systemHealthSummarySeverity | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.2 | OCTET STRING | read-only | System health summary severity. |
| systemHealthSummaryTable | 1.3.6.1.4.1.2.3.51.2.2.7.2 | not-accessible | Table of System Health summary. Contains more detailed information about the reasons for the overall system health status. | |
| INT systemInventory | 1.3.6.1.4.1.2.3.51.2.4.2.3.10 | INTEGER | read-write | Generate an alert if the a processor blade or media tray is added or removed. |
| INT systemIO | 1.3.6.1.4.1.2.3.51.2.4.2.3.17 | INTEGER | read-write | Generate an alert for any informational condition on I/O module. |
| INT systemLog75PctFull | 1.3.6.1.4.1.2.3.51.2.4.2.3.11 | INTEGER | read-write | Generate an alert if the system log reaches 75% full. |
| INT systemPower | 1.3.6.1.4.1.2.3.51.2.4.2.3.19 | INTEGER | read-write | Generate an alert for any informational condition on power module. |
| INT systemPWRDO | 1.3.6.1.4.1.2.3.51.2.4.2.3.22 | INTEGER | read-write | Generate an alert for any informational condition on power on and power off. |
| INT systemRemoteLogin | 1.3.6.1.4.1.2.3.51.2.4.2.3.15 | INTEGER | read-write | Generate an alert if the system detects a new user logged in from a remote site. |
| INT systemStorage | 1.3.6.1.4.1.2.3.51.2.4.2.3.18 | INTEGER | read-write | Generate an alert for any informational condition on a Storage module. |
| INT tcm | 1.3.6.1.4.1.2.3.51.2.4.1.5.3 | INTEGER | read-write | Enable/Disable TCP command mode (TCM) access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. |
| tcpApplicationConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.4 | |||
| tcpPortAssignmentCfg | 1.3.6.1.4.1.2.3.51.2.4.9.3.5 | |||
| INT tcpPortsRestoreDefault | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.1 | INTEGER | read-write | Reset all ports to default value. http: 80 https: 443 telnet: 23 ssh: 22 SNMP agent: 161 SNMP trap: 162 TCP Command Mode: 6090 Secure TCP Command Mode: 6091 FTP: 21 FTP Data: 20 TFTP: 69 SLP: 427 CIM: 5989 NOTE: Value returned for the GET command is meaningless for this MIB object. |
| tcpProtocols | 1.3.6.1.4.1.2.3.51.2.4.9.3 | |||
| INT telnetEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.9 | INTEGER | read-write | Disable/Enable telnet. NOTE: Change to telnet enable/disable will take effect immediately. |
| INT telnetInactivityTimeout | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.1 | INTEGER | read-write | Default is 120 seconds. Value of zero is no timeout. Max value is any positive 4 bytes value. Note that SSH also uses this timeout value to wait before disconnecting inactive SSH connections. |
| INT telnetPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.4 | INTEGER | read-write | Telnet port number. Default value is 23. Port change will take effect immediately. |
| temperature | 1.3.6.1.4.1.2.3.51.2.2.1 | |||
| INT temperatureBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.3 | INTEGER | read-only | Indicates whether the server blade specified exists or not. |
| INT temperatureBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.2 | INTEGER | read-only | The numeric blade ID. |
| OCT temperatureBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.5 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| INT temperatureBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.4 | INTEGER | read-only | Indicates the power state of the blade specified. |
| OCT temperatureCPU1 | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.6 | OCTET STRING | read-only | The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU1HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.6 | OCTET STRING | read-only | The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU1Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.7 | OCTET STRING | read-only | The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU1WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.8 | OCTET STRING | read-only | The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU2 | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.7 | OCTET STRING | read-only | The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU2HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.9 | OCTET STRING | read-only | The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU2Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.10 | OCTET STRING | read-only | The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU2WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.11 | OCTET STRING | read-only | The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU3 | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.8 | OCTET STRING | read-only | The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU3HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.12 | OCTET STRING | read-only | The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU3Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.13 | OCTET STRING | read-only | The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU3WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.14 | OCTET STRING | read-only | The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU4 | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.9 | OCTET STRING | read-only | The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU4HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.15 | OCTET STRING | read-only | The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU4Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.16 | OCTET STRING | read-only | The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureCPU4WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.17 | OCTET STRING | read-only | The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureDASD1 | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.10 | OCTET STRING | read-only | The blade DASD temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureDASD1HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.18 | OCTET STRING | read-only | The blade DASD hard shutdown temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureDASD1Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.19 | OCTET STRING | read-only | The blade DASD warning temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureDASD1WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.20 | OCTET STRING | read-only | The blade DASD warning reset temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| INT temperatureIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.1 | INTEGER | read-only | Blade temperatures table index. |
| OCT temperatureSensor1HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.22 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor1Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.23 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor1WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.24 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor2HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.25 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor2Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.26 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor2WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.27 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor3HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.28 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor3Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.29 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor3WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.30 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor4HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.31 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor4Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.32 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor4WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.33 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor5HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.34 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor5Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.35 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor5WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.36 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor6HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.37 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor6Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.38 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor6WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.39 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor7HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.40 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor7Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.41 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor7WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.42 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor8HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.43 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor8Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.44 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor8WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.45 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor9HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.46 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor9Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.47 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| OCT temperatureSensor9WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.48 | OCTET STRING | read-only | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. |
| INT temperatureThresholdBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.3 | INTEGER | read-only | Indicates whether the server blade specified exists or not. |
| INT temperatureThresholdBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.2 | INTEGER | read-only | The numeric blade ID. |
| OCT temperatureThresholdBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.5 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| INT temperatureThresholdBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.4 | INTEGER | read-only | Indicates the power state of the blade specified. |
| INT temperatureThresholdIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.1 | INTEGER | read-only | Blade temperature threshold table index. |
| INT tftpEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.19 | INTEGER | read-write | Disable/Enable TFTP. |
| INT tftpPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.15 | INTEGER | read-write | TFTP port number. Default value is 69. |
| INT trackingIP | 1.3.6.1.4.1.2.3.51.2.4.1.1.11 | INTEGER | read-write | This option indicates tracking different IP addresses for the same user is enabled or not. If it is enabled then an access every second from alternating IP addresses will result in multiple log entries, regardless of the time duration set in the 'authenticaionLoggingTimeout'field. If this flag is disabled, multiple accesses by varying IP addresses will only be logged as 'new' accesses if they are out of the 'authenticationLoggingTimeout'. |
| OCT trespassMessage | 1.3.6.1.4.1.2.3.51.2.4.3.4 | OCTET STRING | read-write | The value of the trespass warning message. |
| INT trespassWarning | 1.3.6.1.4.1.2.3.51.2.4.3.2 | INTEGER | read-write | If enabled, a customizable trespass warning message is displayed via the Web and CLI interfaces. |
| INT trespassWarningDefault | 1.3.6.1.4.1.2.3.51.2.4.3.3 | INTEGER | read-write | Reset the trespass warning to default value. NOTE: Value returned for the GET command is meaningless for this MIB object. |
| uplinkCheckConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.7 | |||
| INT uplinkCheckDelay | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.2 | INTEGER | read-write | Delay, in minutes (1-2880), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM. |
| INT uplinkCheckEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.1 | INTEGER | read-write | Disable or enable network uplink checking for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM. |
| INT userAuthenticationMethod | 1.3.6.1.4.1.2.3.51.2.4.1.1.7 | INTEGER | read-write | Use this field to specify how users attempting to login should be authenticated. There are two methods: Local authentication. Userid and password are verified by searching the list of users locally configured under Local Login Profiles. LDAP based authentication. Users are authenticated via a remote LDAP server. One or both authentication methods can be selected. If both methods should be used, the order must be specified. |
| userInterfaces | 1.3.6.1.4.1.2.3.51.2.4.1.5 | |||
| users | 1.3.6.1.4.1.2.3.51.2.2.17 | |||
| vlanCMMEntry | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1 | not-accessible | VLAN entries. | |
| ENT vlanCMMEntryStatus | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.4 | EntryStatus | read-write | This object manages the creation and deletion of this entry. The steps recommended to add a new VLAN entry are: 1. Create a new entry in this table vlanCMMEntryStatus = createRequest 2. Set vlanCMMVlanId as required. Then the entry will be valid. valid(1) - Indicates that this entry is available for use. createRequest(2) - A new entry will be created in this table and will transition to the vlanCMMEntryStatus value of underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to the value underCreation(3). invalid(4) - Deletes this entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) cannot be deleted. |
| INT vlanCMMIndex | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.1 | INTEGER | read-only | Index for VLAN entry. If vlanCMMIndex is equal to 1, it is the Default VLAN entry and cannot be deleted. |
| IP vlanCMMIPv4Address | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.31 | IpAddress | read-write | This object sets the IPv4 address for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| IP vlanCMMIPv4Gateway | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.32 | IpAddress | read-write | This object sets the IPv4 address for the IP gateway for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP gateway for the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP gateway of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| IP vlanCMMIPv4Mask | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.33 | IpAddress | read-write | This object sets the IPv4 subnet mask for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the subnet mask of the ethernet interface. The subnet mask of the default VLAN entry can only change by changing the subnet mask of the ethernet interface. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| IP vlanCMMIPv4SubnetRoute1 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.51 | IpAddress | read-write | This object sets the IPv4 address of the subnet route 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| IP vlanCMMIPv4SubnetRoute2 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.53 | IpAddress | read-write | This object sets the IPv4 address of the subnet route 2 for VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| IP vlanCMMIPv4SubnetRoute3 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.55 | IpAddress | read-write | This object sets the IPv4 address of the subnet route 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| IP vlanCMMIPv4SubnetRouteMask1 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.52 | IpAddress | read-write | This object sets the IPv4 subnet route mask 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| IP vlanCMMIPv4SubnetRouteMask2 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.54 | IpAddress | read-write | This object sets the IPv4 subnet route mask 2 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| IP vlanCMMIPv4SubnetRouteMask3 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.56 | IpAddress | read-write | This object sets the IPv4 subnet route mask 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| ADR vlanCMMIPv6Address | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.71 | InetAddressIPv6 | read-write | This object sets the IPv6 address for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| INT vlanCMMIPv6AddressPrefixLen | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.72 | INTEGER | read-write | This object sets the IPv6 address prefix length for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| ADR vlanCMMIPv6Gateway | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.73 | InetAddressIPv6 | read-write | This object sets the IPv6 address for the IP gateway for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP gateway for the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP gateway of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| ADR vlanCMMIPv6SubnetRoute1 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.91 | InetAddressIPv6 | read-write | This object sets the IPv6 address of the subnet route 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| ADR vlanCMMIPv6SubnetRoute2 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.93 | InetAddressIPv6 | read-write | This object sets the IPv6 address of the subnet route 2 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| ADR vlanCMMIPv6SubnetRoute3 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.95 | InetAddressIPv6 | read-write | This object sets the IPv6 address of the subnet route 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| INT vlanCMMIPv6SubnetRoutePrefixLen1 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.92 | INTEGER | read-write | This object sets the IPv6 address prefix length of the subnet route 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| INT vlanCMMIPv6SubnetRoutePrefixLen2 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.94 | INTEGER | read-write | This object sets the IPv6 address prefix length of the subnet route 2 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| INT vlanCMMIPv6SubnetRoutePrefixLen3 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.96 | INTEGER | read-write | This object sets the IPv6 address prefix length of the subnet route 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). |
| OCT vlanCMMName | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.3 | OCTET STRING | read-write | This object allows the user to configure a text string name for this VLAN entry. This entry name is only used as a label for this entry. |
| INT vlanCMMSOLAccess | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.6 | INTEGER | read-write | This object allows the user to set whether the VLAN for this entry will have access to the Serial Over LAN (SOL) interface. Only one VLAN entry may have this object set to enable(1). By default, the entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to enable(1). To set this object to enable(1) on another entry, this object must first be set to disable(0) on any entry that has this object set to enable(1). |
| INT vlanCMMState | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.5 | INTEGER | read-write | This object indicates whether this VLAN entry is enabled or disabled and allows the user to disable, enable or restart this entry except for the exceptions noted below. The entry with a vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to enable(1) and cannot be set to any other value. Other table entries do not have this restriction. Some other objects in this table may not take effect after a change until either this object is: set to enable(1) if this object currently has the value of disable(0), or set to restart(2) if this object currently has the value of enable(1). The other objects in this table that require this object be set to enable(1) or restart(2) after a change are noted in the description for those objects. |
| vlanCMMTable | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20 | not-accessible | This table contains the VLAN configuration objects. The default entry has an vlanCMMIndex equal to 1. The objects for this default entry are configurable. An additional VLAN entry may be added by setting the object, vlanCMMEntryStatus, at vlanCMMIndex=2 to the value of createRequest(2) and also setting the object, vlanCMMVlanId, at vlanCMMIndex=2 to a valid, unique value. IMPORTANT NOTE: Any changes to the object of this table will revert back to their previous settings if the changes are not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout. | |
| INT vlanCMMTableCacheTimeout | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.21 | INTEGER | read-only | The timeout value (in seconds) of the cached data for the table, vlanCMMTable. This value is static (constant) and cannot be set. |
| INT vlanCMMTagging | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.8 | INTEGER | read-write | This object allows the user to set whether VLAN tagging is enabled for this VLAN entry. This object is only configurable for the entry with the vlanCMMIndex value of 1. By default, the entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to disable(0), all other entries will have this object set to enable(1). |
| INT vlanCMMVlanId | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.2 | INTEGER | read-write | Valid VLAN ID. Allowed values are 5..4094. If the entry is not valid, this object will have the value of 0. If this entry has the vlanCMMIndex value of 1 (default VLAN entry), then setting this object will take effect immediately. For other entries, when this object is set, this entry must have the object, vlanCMMState set to enable(1) or restart(2) for this change to take effect. |
| INT vlanCommitState | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.3 | INTEGER | read-write | This object gives the status of whether there are VLAN-related changes pending that need to be committed, and allows a user to commit (save) any VLAN changes. If changes are pending, reading this object will give a value of commitNeeded(2). If no changes are pending, this object will have the value of noChangesPending(1). To save any VLAN-related changes so they do not revert back to previous settings, set this object to executeCommit(3) whenever this object has a value of commitNeeded(2). |
| INT vlanCommitTimeout | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.2 | INTEGER | read-write | This object is the number of minutes from the last VLAN-related object change until any non-committed changes will revert back to their previous settings. This means if a user makes a change that disrupts TCP/IP access to the CMM, the change will revert back to its previous setting after the number of minutes in this object. This allows the user to access the CMM again if access is lost through an unintended VLAN setting. Once the changes are committed using the object, vlanCommitState, setting it to executeCommit(3), the changes will be saved in non-volatile memory. The amount of time before uncommitted changes revert back to their previous settings starts from the last change made to any VLAN-related object. If no other change is made, the user has this number of minutes (the number in this object) to commit the changes with vlanCommitState before the changes will revert back. The default setting for this object is 2 minutes. IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout. |
| vlanConfigure | 1.3.6.1.4.1.2.3.51.2.4.9.1.20 | |||
| INT vlanGlobalState | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.1 | INTEGER | read-write | This object disables or enables the VLAN feature. The configuration objects for the VLAN are in the vlanCMMTable. The default setting for this object is disable(0). IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout. |
| INT voltageBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.3 | INTEGER | read-only | Indicates whether the server blade specified exists or not. |
| INT voltageBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.2 | INTEGER | read-only | The numeric blade ID. |
| OCT voltageBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.5 | OCTET STRING | read-only | The name of the blade as a null terminated string. |
| INT voltageBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.4 | INTEGER | read-only | Indicates the power state of the blade specified. |
| INT voltageIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.1 | INTEGER | read-only | Blade voltages table index. |
| INT voltageThresholdBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.3 | INTEGER | read-only | Indicates whether the server blade specified exists or not. |
| INT voltageThresholdBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.2 | INTEGER | read-only | The numeric blade ID. |
| OCT voltageThresholdBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.5 | OCTET STRING | read-write | The name of the blade as a null terminated string. |
| INT voltageThresholdBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.4 | INTEGER | read-only | Indicates the power state of the blade specified. |
| INT voltageThresholdIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.1 | INTEGER | read-only | Blade voltage thresholds table index. |
| vpdInformation | 1.3.6.1.4.1.2.3.51.2.2.21 | |||
| INT warnBlade | 1.3.6.1.4.1.2.3.51.2.4.2.2.15 | INTEGER | read-write | Generate an alert for any warning condition on a blade. |
| INT warnChassis | 1.3.6.1.4.1.2.3.51.2.4.2.2.19 | INTEGER | read-write | Generate an alert for any warning condition on chassis. |
| INT warnFan | 1.3.6.1.4.1.2.3.51.2.4.2.2.20 | INTEGER | read-write | Generate an alert for any warning condition on cooling devices. |
| INT warnIO | 1.3.6.1.4.1.2.3.51.2.4.2.2.16 | INTEGER | read-write | Generate an alert for any warning condition on I/O module. |
| INT warnLogFull | 1.3.6.1.4.1.2.3.51.2.4.2.2.10 | INTEGER | read-write | Generate an alert if the system log reaches 100% full. |
| INT warnPower | 1.3.6.1.4.1.2.3.51.2.4.2.2.18 | INTEGER | read-write | Generate an alert for any warning condition on power module. |
| INT warnStorage | 1.3.6.1.4.1.2.3.51.2.4.2.2.17 | INTEGER | read-write | Generate an alert for any warning condition on a Storage module. |
| INT web | 1.3.6.1.4.1.2.3.51.2.4.1.5.4 | INTEGER | read-write | Enable/Disable Web access (HTTP/HTTPS) to the MM. NOTE: Disabling web access to the MM will cause all currently active web sessions to disconnect, and you will no longer be able to access the MM management functions using a web browser. |
RFC description
Manages chassis and system information for IBM Chassis Management Module (CMM) hardware monitoring and control via SNMP.
Start monitoring Cisco Communications Manager Express (CME) router/gateway with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.