CME-MIB :: bladePowerTrendingPeriod

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCME-MIBbladePowerTrendingPeriod

bladePowerTrendingPeriod

Module: CME-MIB

OID (symbolic): CME-MIB::bladePowerTrendingPeriod

OID (numeric): 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Specify time period for blade module power trending information table view.

NOTE: This time period should be configured before displaying the following Power Trending Information table for Blade Module. Since the power trending data is constantly being computed and saved in the management application database, some queries of the bladePowerTrendingSampleTable may not provide information for a very short window of time. If the table returns empty, please wait a short period and retry the query.

What is bladePowerTrendingPeriod?

This value selects the time window, from the last hour up to the last 24 hours, for viewing power trending information for a blade module, and it should be configured before displaying the trending sample table since trending data is continuously computed and a very recent window may not yet have data. It lets an admin choose how far back to look when reviewing a specific blade's historical power draw. For example, setting this to lastHour(0) right after a blade was just installed might return no samples yet, since trending data for that short window hasn't been computed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1
snmpwalk -v2c -c public <target> CME-MIB::bladePowerTrendingPeriod

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1.1
snmpget -v2c -c public <target> CME-MIB::bladePowerTrendingPeriod.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1.1 i <value>

Start monitoring Cisco Communications Manager Express (CME) router/gateway with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CME-MIB::bladePowerTrendingPeriod OID value, configure state conditions and alerts, and monitor any Cisco Communications Manager Express (CME) router/gateway from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2ibmBLADE-MIB
1.3.6.1.4.1.2.3ibmAgentsBLADE-MIB
1.3.6.1.4.1.2.3.51netfinitySupportProcessorAgentBLADE-MIB
1.3.6.1.4.1.2.3.51.2bladeCenterSnmpMIBBLADE-MIB
1.3.6.1.4.1.2.3.51.2.2monitorsBLADE-MIB
1.3.6.1.4.1.2.3.51.2.2.10fuelGaugeBLADE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2.3.51.2.2.10.4moduleInformationCME-MIB
1.3.6.1.4.1.2.3.51.2.2.10.4.1bladeDetailsCME-MIB
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3bladePowerTrendingCME-MIB
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1bladePowerTrendingPeriodCME-MIB