CME-MIB :: bladeDetailsEffectiveClockRate

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCME-MIBbladeDetailsEffectiveClockRate

bladeDetailsEffectiveClockRate

Module: CME-MIB

OID (symbolic): CME-MIB::bladeDetailsEffectiveClockRate

OID (numeric): 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: Blade Module Details Table Effective CPU Clock Rate applies to DPM blades only. It displays processor's effective clock rate based on sample interval. Note that some blades do not effective clock rate. In this case, 'notApplicable' will be displayed.

NOTE: The effective clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The effective clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4.

What is bladeDetailsEffectiveClockRate?

This value reports a DPM blade's effective CPU clock rate based on a sample interval, showing notApplicable for blades that do not support this measurement, and is reported only on the primary slot for multi-wide blades. It lets an admin see the actual running clock speed of a blade's processor, which can be lower than the rated maximum under power-saving or thermal constraints. For example, a blade normally rated at 2.4GHz showing an effective clock rate of 1.8GHz might indicate dynamic power saver mode is throttling performance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4
snmpwalk -v2c -c public <target> CME-MIB::bladeDetailsEffectiveClockRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4.1
snmpget -v2c -c public <target> CME-MIB::bladeDetailsEffectiveClockRate.1

Start monitoring Cisco Communications Manager Express (CME) router/gateway with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CME-MIB::bladeDetailsEffectiveClockRate OID value, configure state conditions and alerts, and monitor any Cisco Communications Manager Express (CME) router/gateway from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2ibmBLADE-MIB
1.3.6.1.4.1.2.3ibmAgentsBLADE-MIB
1.3.6.1.4.1.2.3.51netfinitySupportProcessorAgentBLADE-MIB
1.3.6.1.4.1.2.3.51.2bladeCenterSnmpMIBBLADE-MIB
1.3.6.1.4.1.2.3.51.2.2monitorsBLADE-MIB
1.3.6.1.4.1.2.3.51.2.2.10fuelGaugeBLADE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2.3.51.2.2.10.4moduleInformationCME-MIB
1.3.6.1.4.1.2.3.51.2.2.10.4.1bladeDetailsCME-MIB
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1bladeDetailsTableCME-MIB
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1bladeDetailsEntryCME-MIB
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4bladeDetailsEffectiveClockRateCME-MIB