bladeDetailsMaximumClockRate

Module: CME-MIB

OID (symbolic): CME-MIB::bladeDetailsMaximumClockRate

OID (numeric): 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: Blade Module Details Table Maximum CPU Clock Rate applies to DPM blades only. It displays processor's maximum clock rate based on sample interval. Note that some blades do not maximum clock rate. In this case, 'notApplicable' will be displayed.

NOTE: The maximum clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The maximum clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4.

What is bladeDetailsMaximumClockRate?

This value reports a DPM blade's maximum CPU clock rate based on a sample interval, showing notApplicable for blades that do not support this measurement, and is reported only on the primary slot for multi-wide blades. It gives an admin the processor's top rated speed to compare against the effective clock rate and judge how much throttling, if any, is occurring. For example, a maximum clock rate of 2.4GHz alongside a much lower bladeDetailsEffectiveClockRate would confirm the blade is currently running well below its full capability.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5
snmpwalk -v2c -c public <target> CME-MIB::bladeDetailsMaximumClockRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5.1
snmpget -v2c -c public <target> CME-MIB::bladeDetailsMaximumClockRate.1

Start monitoring Cisco Communications Manager Express (CME) router/gateway with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CME-MIB::bladeDetailsMaximumClockRate OID value, configure state conditions and alerts, and monitor any Cisco Communications Manager Express (CME) router/gateway from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2ibmBLADE-MIB
1.3.6.1.4.1.2.3ibmAgentsBLADE-MIB
1.3.6.1.4.1.2.3.51netfinitySupportProcessorAgentBLADE-MIB
1.3.6.1.4.1.2.3.51.2bladeCenterSnmpMIBBLADE-MIB
1.3.6.1.4.1.2.3.51.2.2monitorsBLADE-MIB
1.3.6.1.4.1.2.3.51.2.2.10fuelGaugeBLADE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2.3.51.2.2.10.4moduleInformationCME-MIB
1.3.6.1.4.1.2.3.51.2.2.10.4.1bladeDetailsCME-MIB
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1bladeDetailsTableCME-MIB
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1bladeDetailsEntryCME-MIB
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5bladeDetailsMaximumClockRateCME-MIB