RAD-MIB

MIB Reference — IPNetwork Monitor

All MIBsRAD-MIB

Category: System Management

Description:

Manages RAD Data Communications core equipment configuration, system parameters, and operational state.

Imported Objects

From ATM-MIB

atmTrafficDescrParamEntryOBJECT-TYPE
atmVcCrossConnectEntryOBJECT-TYPE
atmVclVciOBJECT-TYPE
atmVclVpiOBJECT-TYPE
atmVpCrossConnectEntryOBJECT-TYPE
atmVplVpiOBJECT-TYPE

From BRIDGE-MIB

BridgeId
Timeout
dot1dBasePortEntryOBJECT-TYPE

From DISMAN-SCHEDULE-MIB

schedEntryOBJECT-TYPE

From DOT3-OAM-MIB

dot3OamEntryOBJECT-TYPE
dot3OamOperStatusOBJECT-TYPE

From DS1-MIB

dsx1CurrentIndexOBJECT-TYPE
dsx1IntervalIndexOBJECT-TYPE
dsx1IntervalNumberOBJECT-TYPE
dsx1LineIndexOBJECT-TYPE
dsx1LineStatusOBJECT-TYPE
dsx1LineStatusLastChangeOBJECT-TYPE
dsx1LoopbackStatusOBJECT-TYPE
dsx1TotalIndexOBJECT-TYPE

From DS3-MIB

dsx3ConfigEntryOBJECT-TYPE
dsx3LineStatusOBJECT-TYPE
dsx3LoopbackStatusOBJECT-TYPE

From IANAifType-MIB

IANAifType

From IEEE8021-CFM-MIB

dot1agCfmMaIndexOBJECT-TYPE
dot1agCfmMdIndexOBJECT-TYPE
dot1agCfmMepDbRMepIdentifierOBJECT-TYPE
dot1agCfmMepIdentifierOBJECT-TYPE

From IF-MIB

InterfaceIndex
ifAliasOBJECT-TYPE
ifDescrOBJECT-TYPE
ifIndexOBJECT-TYPE

From INET-ADDRESS-MIB

InetAddress
InetAddressType

From LLDP-MIB

LldpPortIdSubtype

From PerfHist-TC-MIB

PerfCurrentCount
PerfIntervalCount
PerfTotalCount

From Q-BRIDGE-MIB

PortList
VlanId
dot1qVlanStaticEntryOBJECT-TYPE

From SNMP-FRAMEWORK-MIB

SnmpAdminString

From SNMPv2-SMI

Counter32
Counter64
Gauge32
Integer32
IpAddress
NOTIFICATION-TYPE
OBJECT-IDENTITY
OBJECT-TYPE
TimeTicks
Unsigned32
enterprises

From SNMPv2-TC

DateAndTime
DisplayString
MacAddress
RowPointer
RowStatus
TEXTUAL-CONVENTION
TimeStamp
TruthValue

What Is RAD-MIB?

RAD-MIB is the enterprise base MIB for RAD Data Communications, covering core equipment configuration, system parameters, and operational state for RAD's telecom/networking access devices, with legacy support for token ring and FDDI interfaces. This RAD-MIB MIB exposes objects for hardware/software version identification, trap generation control, configuration change tracking, and a management-station trap-notification table. It supports monitoring of device software health via agnHwVersion (hardware/firmware version reporting), agnChangeCnt (a running counter of configuration changes useful for detecting unauthorized or unexpected reconfiguration), and the trap mask/value objects that indicate which fault conditions the agent is set to report. Notable objects like agnTrapMask and mngTrapIpTable govern how the device forwards alarms to management stations, forming a dependency on the device's overall trap/notification framework. It is deployed in RAD Data Communications access, transmission, and multiplexer equipment used in carrier and enterprise WAN environments.

IPNetwork Monitor allows you to monitor SNMP objects defined in RAD-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • hardware/firmware version
  • configuration change counter
  • trap mask and trap value settings
  • registered management-station trap destinations
  • trap IP address and mask per management entry

Supported Devices

  • RAD Data Communications access/transmission/multiplexer equipment, entire product line (base enterprise MIB)

Monitoring Examples

An operator would poll agnChangeCnt periodically to detect unexpected device reconfiguration, and check agnHwVersion to confirm firmware/hardware revision during an audit. The mngTrapIpTable (via mngEntry, mngID, mngIP, mngIPMask, mngTrapMask) would be inspected to verify which management stations are registered to receive traps and with what trap mask, revealing if a monitoring station has been dropped from the trap destination list. A jump in agnTrapValue combined with agnSpecific would indicate an active alarm condition reported by the agent.

OIDs
OID symbolicOID numericTypeAccessDescription
rad1.3.6.1.4.1.164
radTokenRing1.3.6.1.4.1.164.1
radFddi1.3.6.1.4.1.164.2
radWan1.3.6.1.4.1.164.3
wanGen1.3.6.1.4.1.164.3.1
chasWanGen1.3.6.1.4.1.164.3.1.1
STR chasVersion1.3.6.1.4.1.164.3.1.1.1DisplayStringread-onlyAn ASCII string for description and display of the agent chassis version.
I32 chasTotalNoOfSlt1.3.6.1.4.1.164.3.1.1.2Integer32read-onlyThis entry indicates the number of physical slots in the chassis.
I32 chasTotalNoOfIoSlt1.3.6.1.4.1.164.3.1.1.3Integer32read-onlyThis entry indicates the total number of physical IO slots in the chassis, (not all slots hardware should be occupied and active) .
I32 chasTotalNoOfPsSlt1.3.6.1.4.1.164.3.1.1.4Integer32read-onlyThis entry indicates the number of physical Power Supply slots in the chassis.
I32 chasTotalNoOfClSlt1.3.6.1.4.1.164.3.1.1.5Integer32read-onlyThis entry indicates the number of physical Common Logic slots in the chassis.
agnWanGen1.3.6.1.4.1.164.3.1.2
statAgnGen1.3.6.1.4.1.164.3.1.2.1
INT agnSDateFormat1.3.6.1.4.1.164.3.1.2.1.1INTEGERread-writeThis entry indicates the date and time format used for the agnSDateAndTimeCmd and for the alarm history report.
STR agnSDateCmd1.3.6.1.4.1.164.3.1.2.1.2DisplayStringread-writeThis entry indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the agnSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent.
STR agnSTimeCmd1.3.6.1.4.1.164.3.1.2.1.3DisplayStringread-writeThis entry indicates the current time as it is known by the agent using its own real-time clock. This parameter can be set for time synchronization between the NMS and the Agent.
I32 agnSActiveCnfg1.3.6.1.4.1.164.3.1.2.1.4Integer32read-onlyThis entry specifies the unique identifier of the configuration, that is currently active and running.
I32 agnSEditCnfg1.3.6.1.4.1.164.3.1.2.1.5Integer32read-onlyThis entry indicates the unique identifier of the configuration that is currently loaded into the tmp working space for manipulation and update operations. Value of 255 means no config. is under editing process.
STR agnSLastCnfgFlipTime1.3.6.1.4.1.164.3.1.2.1.6DisplayStringread-onlyThis entry indicates the Date & Time of the last flip to the current configuration at the agent.
STR agnSLastCnfgFlipCause1.3.6.1.4.1.164.3.1.2.1.7DisplayStringread-onlyThis entry describes the flip's cause.
INT agnSEditBy1.3.6.1.4.1.164.3.1.2.1.8INTEGERread-onlyThis entry indicates which MMI application is working on the edited config. The editing phase starts at the first modify operation and ends after an update(load) operation.
INT agnSClkSrc1.3.6.1.4.1.164.3.1.2.1.9INTEGERread-onlyThis entry indicates the source of the system clock.
INT agnSAlrStatus1.3.6.1.4.1.164.3.1.2.1.10INTEGERread-onlyIndicates the alarm state in the agent level, i.e. lower level (card/port) alarms not included. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
INT agnSAlrStatusAll1.3.6.1.4.1.164.3.1.2.1.11INTEGERread-onlyIndicates the alarm state of the entire agent, i.e. including card and port alarms status. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
INT agnSMaskedAlrStat1.3.6.1.4.1.164.3.1.2.1.12INTEGERread-onlyIndicates the alarm state in the agent level,[ i.e. lower level (card/port) alarms not included] including Masked alarms. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
INT agnSMaskedAlrStatAll1.3.6.1.4.1.164.3.1.2.1.13INTEGERread-onlyIndicates the alarm state of the entire agent, i.e. including card and port alarms status,including Masked alarms. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
INT agnSTstStatAll1.3.6.1.4.1.164.3.1.2.1.14INTEGERread-onlyon(3) - when there is at least one test in progress in one of the agent cards, otherwise the value will be off(2).
agnSAlrTable1.3.6.1.4.1.164.3.1.2.1.15not-accessibleList of agent related alarms and indications for alarms at system level.
agnSAlrEntry1.3.6.1.4.1.164.3.1.2.1.15.1not-accessibleAn entry in table.
I32 agnSAlrIdx1.3.6.1.4.1.164.3.1.2.1.15.1.1Integer32read-onlyA unique number to identify an entry in the alarm status table of the agent.
STR agnSAlrCodeDescription1.3.6.1.4.1.164.3.1.2.1.15.1.2DisplayStringread-onlyThis attribute is a full text description of the alarm . The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter.
I32 agnSAlrCode1.3.6.1.4.1.164.3.1.2.1.15.1.3Integer32read-onlyA code identifying the alarm of an entry in the alarm status table at system level.
INT agnSAlrSeverity1.3.6.1.4.1.164.3.1.2.1.15.1.4INTEGERread-onlyThe severity of the alarm.
INT agnSAlrState1.3.6.1.4.1.164.3.1.2.1.15.1.5INTEGERread-onlyState of the alarm.
I32 agnSAlrCounter1.3.6.1.4.1.164.3.1.2.1.15.1.6Integer32read-onlyA counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately.
INT agnSAlrMask1.3.6.1.4.1.164.3.1.2.1.15.1.7INTEGERread-onlyAlarm mask : on/off.
INT agnSAlrInvert1.3.6.1.4.1.164.3.1.2.1.15.1.8INTEGERread-onlyAlarm invert : on/off.
INT agnSClearAlrCmd1.3.6.1.4.1.164.3.1.2.1.16INTEGERread-writeSetting this attribute to ON, enforce a clear operation on all the agent(general) events. General alarms are alarms which are not specific to a card or port. The clear operation will not be applied for masked/inverted alarms.
INT agnSClearAllAlrCmd1.3.6.1.4.1.164.3.1.2.1.17INTEGERread-writeSetting this attribute to ON, enforce a clear operation on all MUX alarm events at the levels of agent, slots and ports. The clear operation will not be applied for masked/inverted alarms.
INT agnSSanityCheckStatus1.3.6.1.4.1.164.3.1.2.1.18INTEGERread-onlyUpon completion of the Sanity check process on the TmpCnfg this attribute will be set to: FAIL(2) - when there is at least one error encountered and possibly some warnings. WARNING(3) - when there are only warnings. otherwise, the value will be OK(4). The value will be UNKNOWN(1) if changes were made in the TmpCnfg following the last Sanity check.
I32 agnSNoOfSanityCheckErr1.3.6.1.4.1.164.3.1.2.1.19Integer32read-onlyThis entry indicates the number of errors/warnings discovered by the last SanityCheck process.
agnSErrListTable1.3.6.1.4.1.164.3.1.2.1.20not-accessibleList of errors and warnings found during Sanity Check process.
agnSErrListEntry1.3.6.1.4.1.164.3.1.2.1.20.1not-accessibleAn entry in table.
I32 agnSErrIdx1.3.6.1.4.1.164.3.1.2.1.20.1.1Integer32read-onlyUnique number to identify an entry in the error list table. The maximum entry value cannot exceed the value of 'agnSNoOfSanityCheckErr'.
STR agnSErrDescription1.3.6.1.4.1.164.3.1.2.1.20.1.2DisplayStringread-onlyThis attribute is a full text description of the sanity check error including error code, slot and port numbers related to the code .
I32 agnSMaxNoOfCnfg1.3.6.1.4.1.164.3.1.2.1.21Integer32read-onlyMaximum number of configurations that can be defined and stored in the MUX. If the mux has a large capacity, the maximum will be limited to 254.
agnSCnfgTable1.3.6.1.4.1.164.3.1.2.1.22not-accessibleThis table contains an entry per configuration. It indicates if the configuration is valid.
agnSCnfgEntry1.3.6.1.4.1.164.3.1.2.1.22.1not-accessibleAn entry in table.
I32 agnSEntryIdx1.3.6.1.4.1.164.3.1.2.1.22.1.1Integer32read-onlyUnique number to identify an entry in the configuration table.
INT agnSEntryIsValid1.3.6.1.4.1.164.3.1.2.1.22.1.2INTEGERread-onlyThis attribute indicates whether the specific configuration is valid in the MUX . Value of NO indicates: no such configuration in the MUX.
cnfgAgnGen1.3.6.1.4.1.164.3.1.2.2
INT agnCSanityCheckCmd1.3.6.1.4.1.164.3.1.2.2.1INTEGERread-writeSetting this attribute to on(3) will initiate the process of Sanity check on the TmpCnfg. Upon completion the value will automatically be changed to off(2).
I32 agnCSaveCnfgIdxCmd1.3.6.1.4.1.164.3.1.2.2.2Integer32read-writeThis attribute specifies the Id of the target RealCnfg to which the TmpCnfg should be transferred. Upon set command the MUX will initiate the Sanity-Check process first. If successful, the actual transfer will be performed. If warnings are detected, the user will have to perform the command again to confirm the operation. Setting this object a second time to the same value without performing any change in the database, will cause the result: agnSSanityCheckStatus = unknown
I32 agnCLoadCnfgIdxCmd1.3.6.1.4.1.164.3.1.2.2.3Integer32read-writeThis attribute specifies the Id of the source Cnfg to be loaded into the TmpCnfg. Upon set operation the actual transfer will be initiated. The operation is valid only on Valid configurations (agnSEntryIsValid)
agnCClkSrcTable1.3.6.1.4.1.164.3.1.2.2.4not-accessibleAll the entries of this table are identical (have the same value) for all the configurations (1..100) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
agnCClkSrcEntry1.3.6.1.4.1.164.3.1.2.2.4.1not-accessibleAn entry in table.
I32 agnCClkCnfgIdx1.3.6.1.4.1.164.3.1.2.2.4.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg(1..100) being accessed and Idx 255 relates to the TmpCnfg.
I32 agnCClkSrcIdx1.3.6.1.4.1.164.3.1.2.2.4.1.2Integer32read-onlyAn index to the table. There are only two entries to this table. Index 1 points to the Master clock parameters and Index 2 points to the Fallback clock parameters
INT agnCClkSrcMode1.3.6.1.4.1.164.3.1.2.2.4.1.3INTEGERread-writeThe source of the nodal timing.
INT agnCClkSrcSlt1.3.6.1.4.1.164.3.1.2.2.4.1.4INTEGERread-writeThis entry is valid only when we are working in rxClk mode. For an invalid entry, the return value will be '7fff'h.
I32 agnCClkSrcPrt1.3.6.1.4.1.164.3.1.2.2.4.1.5Integer32read-writeThis entry is valid only when we are working in rxClk or adaptive mode. For an invalid entry, the return value will be '7fff'h. - For rxClk mode, the values can be: exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , notApplicable (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) - For adaptive mode, the value will be the ifIndex of the selected IP Bundle.
I32 agnCDeleteCnfgIdxCmd1.3.6.1.4.1.164.3.1.2.2.5Integer32read-writeSetting this attribute will delete the requested DB from the NVRAM .
I32 agnCDefaultCnfgIdxCmd1.3.6.1.4.1.164.3.1.2.2.6Integer32read-writeSetting this attribute will define the desired working configuration when no conditions of the Flip DB Table are fulfilled and no Net GO command was issued. This command will be accepted only if the Configuration number exists (agnSEntryIsValid=yes).
agnCnfgDataTable1.3.6.1.4.1.164.3.1.2.2.7not-accessibleThis table contains data about the agent configurations. The table will support only data about valid configurations of the agent.
agnCnfgDataEntry1.3.6.1.4.1.164.3.1.2.2.7.1not-accessibleAn entry in table.
I32 agnCnfgIdx1.3.6.1.4.1.164.3.1.2.2.7.1.1Integer32read-onlyThis object indicates the Idx of the agent' Cnfg the following objects refer. 255=Temporary Cnfg (Set is done only to this configuration).
STR agnCnfgDesc1.3.6.1.4.1.164.3.1.2.2.7.1.2DisplayStringread-writeThis object is a description of the Configuration, entered by user, to enhance Cnfg recognition.
STR agnCnfgUpdDate1.3.6.1.4.1.164.3.1.2.2.7.1.3DisplayStringread-onlyThis object indicates the date when last update of this configuration was performed, as it is known by the agent using its own real-time clock. The format would be as specified by the agnSDateFormat. When update is performed, the agent should save the date.
STR agnCnfgUpdTime1.3.6.1.4.1.164.3.1.2.2.7.1.4DisplayStringread-onlyThis object indicates the time when last update of this configuration was performed, as it is known by the agent using its own real-time clock. When update is performed, the agent should save the time.
IP agnCnfgUpdMnger1.3.6.1.4.1.164.3.1.2.2.7.1.5IpAddressread-onlyThis object indicates the IP Address of the Manager who performed the last update of this configuration. When update is performed, the agent should save the IP Address of the Manager who commanded the update. That will enable a manager to know if he performed the last update, or another manager did.
agnCnfgAlarm1.3.6.1.4.1.164.3.1.2.2.8
I32 agnCnfgAlrFilterWindow1.3.6.1.4.1.164.3.1.2.2.8.1Integer32read-writeWindow of time, in seconds. During this Window, the alarms filter is performed. Same Window for all agent alarms that need filtering. Upon end of the Window, the state of the alarm is updated and a new Window starts. If no alarm needs filtering, this object's value will not be used.
agnCnfgAlrTable1.3.6.1.4.1.164.3.1.2.2.8.2not-accessibleThis table enables the user to set attributes to each alarm. Setting for a non-existing entry agnCnfgAlrMask, agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave for Mask) will add this new entry to the table. Setting for an existing entry agnCnfgAlrMask/ agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no' (noAndSave for Mask) so that ALL these objects' values are 'no' , will delete this entry from the table. For agnCnfgAlrMask, only if [(last saved value=noAndSave) AND (new value is 'no' or 'noAndSave')] the object's value is considered 'no' for deleting the entry. For some products (like MP, MPH, Vmux2100) the Active Alarms are always part of the table and cannot be removed even if their Mask/Invert/Filter are No.
agnCnfgAlrEntry1.3.6.1.4.1.164.3.1.2.2.8.2.1not-accessibleAn entry in table.
I32 agnCnfgAlrCode1.3.6.1.4.1.164.3.1.2.2.8.2.1.1Integer32read-onlyThe alarm code. The following attributes refer this code.
INT agnCnfgAlrSlot1.3.6.1.4.1.164.3.1.2.2.8.2.1.2INTEGERread-onlyThe alarm slot. The following attributes apply for the alarm code and slot selected. all = the attributes apply to all slots. notApplicable = the selected alarm is for system level. For the Vmux2100 Main Board clA (3) is used.
I32 agnCnfgAlrPort1.3.6.1.4.1.164.3.1.2.2.8.2.1.3Integer32read-onlyThe alarm port. The following attributes apply for the alarm code,slot and port selected. 200 = all = the attributes apply to all ports of the selected slot. When selected Slot is 'all', only 'all' or 'notApplicable' are valid Port selections. notApplicable = the selected alarm is for system or card level. =255 for MP =100 for DXC - For MP: - valid cards' ports are: exPrt1(1)..exPrt16(16) inPrt1(101)..inPrt48 (148) - IP Bundles - For DXC, the port index will include the Slot, as for all DXC tables: [(IO Slot+10)&n] ; n=odd for external ports n=even for internal ports.
INT agnCnfgAlrMask1.3.6.1.4.1.164.3.1.2.2.8.2.1.4INTEGERread-writeAn attribute defining the desired Mask state of an alarm . no - unmask (this command is not saved in agent's common database) noAndSave - unmask ; this command is saved in agent's common database yes - mask (this command is not saved in agent's common database) yesAndSave - mask ; this command is saved in agent's common database. Commands that are not saved, will be lost upon power-up or selected card removal.
INT agnCnfgAlrInvert1.3.6.1.4.1.164.3.1.2.2.8.2.1.5INTEGERread-writeAn attribute defining the desired Invert state of an alarm . no - not inverted. yes - inverted. For MP, it is not applicable for alarms that are currently OFF.
INT agnCnfgAlrFilter1.3.6.1.4.1.164.3.1.2.2.8.2.1.6INTEGERread-writeAn attribute defining if Filter is desired for the alarm . no - no filter. yes - filter activate. This filter is activated within a window of time defined by agnCnfgAlrFilterWindow. Its purpose is to avoid frequent changes of an alarm between ON/OFF states.
I32 agnCnfgAlrFilterSet1.3.6.1.4.1.164.3.1.2.2.8.2.1.7Integer32read-writeThis is a top threshold causing the alarm that passes it, to be declared Set (ON) at the end of the respective window of time. - For alarms defined by default as state alarms (minor,major) this value will be in [%]. - For alarms defined by default as events, this value will be an integer meaning how many times this event should appear at least, during the window in order to be considered ON. The maximum value will be 255. This value should be greater than the one of agnCnfgAlrFilterReset. Agents that do not support Alarms Filter, will return 0.
I32 agnCnfgAlrFilterReset1.3.6.1.4.1.164.3.1.2.2.8.2.1.8Integer32read-writeThis is a bottom threshold causing the alarm that does not pass it, to be declared Reset (ON) at the end of the respective window of time. - For alarms defined by default as state alarms (minor,major) this value will be in [%]. - For alarms defined by default as events, this value will be an integer meaning how many times this event should appear at most, during the window, in order to be considered OFF. This value should be less than the one of agnCnfgAlrFilterSet. Agents that do not support Alarms Filter, will return 0.
INT agnCnfgAlrSeverity1.3.6.1.4.1.164.3.1.2.2.8.2.1.9INTEGERread-writeAn attribute defining desired severity of an alarm code per slot/port
agnCnfgAlrReportTable1.3.6.1.4.1.164.3.1.2.2.8.3not-accessibleThis table enables the user to configure the desired Alarm Reports according to alarms severity.
agnCnfgAlrReportEntry1.3.6.1.4.1.164.3.1.2.2.8.3.1not-accessibleAn entry in table.
INT agnCnfgAlrReportType1.3.6.1.4.1.164.3.1.2.2.8.3.1.1INTEGERread-onlyThe alarm report type. trap - traps will be sent only for alarms having the selected On/Off severity or higher. buffer - only alarms having the selected On/Off severity and higher, will be reported to the buffer. relay - relay contact will be activated only for alarms having the selected On severity or higher. For products having 2 relays, this is the R1 Relay. alrLedOn/alrLedBlink - user should select a higher severity (ReportOn) for alrLedBlink than for alrLedOn (Blinking Led means a more severe alarm than steady ON Led). alrLedOn - MTCL-1 Alarm Led will be ON only when agnSAlrStatusAll equals the selected severity or higher, but lower severity than that selected for 'alrLedBlink'. For products having 2 LEDs, this is the Minor LED. alrLedBlink - MTCL-1 Alarm Led will Blink only when agnSAlrStatusAll equals the selected severity or higher. For products having 2 LEDs, this is the Major LED. relay2 - relay 2 contact will be activated only for alarms having the selected On severity or higher. This is the R2 Relay.
INT agnCnfgAlrStartReportOn1.3.6.1.4.1.164.3.1.2.2.8.3.1.2INTEGERread-writeThis object specifies the severity from which alarms will be reported. Alarms having this severity or higher, will be reported. This object specifies the report severity only for alarms that turn to ON state. noReport - no Report at all (for any severity).
INT agnCnfgAlrStartReportOff1.3.6.1.4.1.164.3.1.2.2.8.3.1.3INTEGERread-writeThis object specifies the severity from which alarms will be reported. Alarms having this severity or higher, will be reported. This object specifies the report severity only for alarms that turn to OFF state. notApplicable - for 'relay','alrLedOn','alrLedBlink', 'relay2' report types, in MP. noReport - no Report at all (for any severity).
INT agnCOffsetCmd1.3.6.1.4.1.164.3.1.2.2.9INTEGERread-writeAn object defining special user request. notApplicable - is RO value for products that do not support this object. normal - nothing special u1 - user 1 - for all Voice cards, the DISPLAYED Tx and Rx Levels will have the following Offsets: - 2 Wires port: Tx Level: the base value (for 0dBm) = 0 Rx Level: the base value (for 0dBm) = -2 - 4 Wires port: Tx Level: the base value (for 0dBm) = -16 Rx Level: the base value (for 0dBm) = 7 The MIB and application DB will use the values without Offset.
agnCT1E1RingTable1.3.6.1.4.1.164.3.1.2.2.10not-accessibleConfiguration of all T1/E1 Ring ML cards and ports. The write operation into the table objects is valid only for the TmpCnfg. A Slot/Port that does not participate in the T1/E1 Ring, will not exist in this table. A ML port that exists in this table, cannot exist at the same time in the IO Redundancy table (sysCRdnTable).
agnCT1E1RingEntry1.3.6.1.4.1.164.3.1.2.2.10.1not-accessibleAn Entry in table agnCT1E1RingTable
I32 agnCT1E1RingCnfgIdx1.3.6.1.4.1.164.3.1.2.2.10.1.1Integer32read-onlyThis object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
INT agnCT1E1RingPrimeSlot1.3.6.1.4.1.164.3.1.2.2.10.1.2INTEGERread-onlyThe slot number of the Primary card of the Ring Pair.
I32 agnCT1E1RingPrimePort1.3.6.1.4.1.164.3.1.2.2.10.1.3Integer32read-onlyThe port number in the Primary Card. For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104
INT agnCT1E1RingSecSlot1.3.6.1.4.1.164.3.1.2.2.10.1.4INTEGERread-createThe slot number of the Secondary card of the Ring Pair.
I32 agnCT1E1RingSecPort1.3.6.1.4.1.164.3.1.2.2.10.1.5Integer32read-createThe port number in the Secondary Card. For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104
I32 agnCT1E1RingRecTime1.3.6.1.4.1.164.3.1.2.2.10.1.6Integer32read-createT1/E1 Ring Recovery Time (sec). Valid Values: 1..99, 65535. 65535=NA.
ROW agnCT1E1RingRowStatus1.3.6.1.4.1.164.3.1.2.2.10.1.7RowStatusread-createThis parameter allows NMS to create/delete entries of this table. The only possible supported RowStatus vaules are active (1) and destroy (6).
U32 agnCT1E1RingWTR1.3.6.1.4.1.164.3.1.2.2.10.1.8Unsigned32read-createT1/E1 Ring Wait to Restore (sec). Valid Values: 0..999, 65535. 65535=NA. When the value <> 65535, the value of agnCT1E1RingRecTime must be 65535.
INT agnCT1E1RingDualFailDetection1.3.6.1.4.1.164.3.1.2.2.10.1.9INTEGERread-createT1/E1 Ring - Dual Failure Detection enable/disable.
INT agnCMainExitPort1.3.6.1.4.1.164.3.1.2.2.11INTEGERread-writeAn object defining the Main Exit Port for the Data of the device. In the Vmux-120 Device the Data can Exit via one of the 2 existing ports: 1. Ethernet port (2) 2. A port that can be E1 or T1 or a Serial Link (3).
agnCBuMlTable1.3.6.1.4.1.164.3.1.2.2.12not-accessibleConfiguration for Primary, Secondary and Third Link. These are used for Link Backup.
agnCBuMlEntry1.3.6.1.4.1.164.3.1.2.2.12.1not-accessibleAn Entry in table agnCBuMlTable
I32 agnCBuMlCnfgIdx1.3.6.1.4.1.164.3.1.2.2.12.1.1Integer32not-accessibleThis object indicates the Index of the Configuration database (1..255) being accessed. Index of 255 relates to the Temporary Configuration.
INT agnCBuMlRole1.3.6.1.4.1.164.3.1.2.2.12.1.2INTEGERnot-accessibleThe Role of the Link. Primary Link is the Link that should usually work. If the Primary Link fails, the data will go through the Secondary Link. If both Primary and Secondary Links fail, the data will go through the Third Link, provided it is up.
INT agnCBuMlType1.3.6.1.4.1.164.3.1.2.2.12.1.3INTEGERread-writeThe Type of the Link. For E1/T1 the Link can be Link A - e1T1a or Link B - e1T1b.
IP agnCBuMlDefaultGateway1.3.6.1.4.1.164.3.1.2.2.12.1.4IpAddressread-writeDefault Gateway's IP Address.
IP agnCBuMlSubnetMask1.3.6.1.4.1.164.3.1.2.2.12.1.5IpAddressread-writeThe Link subnet mask.
I32 agnCBuMlOamFrequency1.3.6.1.4.1.164.3.1.2.2.12.1.6Integer32read-writeTime in sec. between 2 OAM packets.
I32 agnCBuMlOamTimeoutCycles1.3.6.1.4.1.164.3.1.2.2.12.1.7Integer32read-writeNo. of cycles the Link will send OAM packets without receiving a response from the remote Link before switching to the Backup Link.
U32 agnCBuMlWaitToRestore1.3.6.1.4.1.164.3.1.2.2.12.1.8Unsigned32read-writeThis object defines traffic recovery time (in milliseconds) of the link after its recovery. This object is applicable only when Recovery Mode is revertive.
agnCQ50Table1.3.6.1.4.1.164.3.1.2.2.13not-accessibleTable for the device Q50 parameters. Q50 is a Signaling protocol used between PBX devices. It is possible to control the initiation of calls using Q.50. This is useful for devices when there is a congestion.
agnCQ50Entry1.3.6.1.4.1.164.3.1.2.2.13.1not-accessibleAn Entry in table agnCQ50Table
I32 agnCQ50CnfgIdx1.3.6.1.4.1.164.3.1.2.2.13.1.1Integer32not-accessibleThis object indicates the Index of the Configuration database (1..255) being accessed. Index of 255 relates to the Temporary Configuration.
I32 agnCQ50StopCallsThresh1.3.6.1.4.1.164.3.1.2.2.13.1.2Integer32read-writeThis object indicates the Bandwidth Threshold percent (%) above which new Calls from the PBX will be disabled.
I32 agnCQ50DiscardPktThresh1.3.6.1.4.1.164.3.1.2.2.13.1.3Integer32read-writeThis object indicates the Bandwidth Threshold percent (%) above which voice packets will be discarded. Usually, the value selected should be higher than the value of agnCQ50StopCallsThresh.
I32 agnCQ50BlockNewModemVbdCallsThresh1.3.6.1.4.1.164.3.1.2.2.13.1.4Integer32read-writeThis object indicates the Modem VBD Calls Threshold percent (%) above which new modem calls will be rejected.
I32 agnCQ50BlockNewModemRelayCallsThresh1.3.6.1.4.1.164.3.1.2.2.13.1.5Integer32read-writeThis object indicates the Modem Relay Calls Threshold percent (%) above which new modem calls will be rejected.
cmprAgnGen1.3.6.1.4.1.164.3.1.2.3
agnCmprTable1.3.6.1.4.1.164.3.1.2.3.1not-accessibleA table.
agnCmprEntry1.3.6.1.4.1.164.3.1.2.3.1.1not-accessibleAn entry in table.
I32 agnCmprTypIdx1.3.6.1.4.1.164.3.1.2.3.1.1.1Integer32read-onlyThis attribute indicates the Type of the Compressed being referred.
I32 agnCmprCnfgIdx1.3.6.1.4.1.164.3.1.2.3.1.1.2Integer32read-onlyThis attribute indicates the configuration to which the Compressed information is related.
I32 agnCmprVersion1.3.6.1.4.1.164.3.1.2.3.1.1.3Integer32read-onlyThis attribute indicates the version of the internal format of the Compressed data
OCT agnCmprObj1.3.6.1.4.1.164.3.1.2.3.1.1.4OCTET STRINGread-writeThis attribute is the compressed information itself.
agnDlciCmprTable1.3.6.1.4.1.164.3.1.2.3.2not-accessibleA table.
agnDlciCmprEntry1.3.6.1.4.1.164.3.1.2.3.2.1not-accessibleAn entry in table.
I32 agnDlciCmprCnfgIdx1.3.6.1.4.1.164.3.1.2.3.2.1.1Integer32read-onlyThis attribute indicates the configuration to which the Compressed information is related.
I32 agnDlciCmprVersion1.3.6.1.4.1.164.3.1.2.3.2.1.2Integer32read-onlyThis attribute indicates the version of the internal format of the Compressed data
I32 agnDlciCmprDlciIdx1.3.6.1.4.1.164.3.1.2.3.2.1.3Integer32read-onlyThis attribute indicates a unique identifier of the Dlci, the compressed information relates to. The values are between 16 - 991.
OCT agnDlciCmprObj1.3.6.1.4.1.164.3.1.2.3.2.1.4OCTET STRINGread-writeThis attribute is the compressed information itself.
agnAlarmsCmprTable1.3.6.1.4.1.164.3.1.2.3.3not-accessibleA table.
agnAlarmsCmprEntry1.3.6.1.4.1.164.3.1.2.3.3.1not-accessibleAn entry in table.
I32 agnAlarmsCmprVersion1.3.6.1.4.1.164.3.1.2.3.3.1.1Integer32read-onlyThis attribute indicates the version of the internal format of the Compressed data
I32 agnAlarmsCmprAlarmIdx1.3.6.1.4.1.164.3.1.2.3.3.1.2Integer32read-onlyA unique number to identify an entry in the alarm status table of the agent.
OCT agnAlarmsCmprObj1.3.6.1.4.1.164.3.1.2.3.3.1.3OCTET STRINGread-onlyThis attribute is the compressed information itself.
agnAlrBufCmprTable1.3.6.1.4.1.164.3.1.2.3.4not-accessibleA table.
agnAlrBufCmprEntry1.3.6.1.4.1.164.3.1.2.3.4.1not-accessibleAn entry in table.
I32 agnAlrBufCmprVersion1.3.6.1.4.1.164.3.1.2.3.4.1.1Integer32read-onlyThis attribute indicates the version of the internal format of the Compressed data
I32 agnAlrBufCmprAlarmIdx1.3.6.1.4.1.164.3.1.2.3.4.1.2Integer32read-onlyA unique number to identify an entry in the history alarms buffer of the agent.
OCT agnAlrBufCmprObj1.3.6.1.4.1.164.3.1.2.3.4.1.3OCTET STRINGread-onlyThis attribute is the compressed information itself.
agnSCmprErrListTable1.3.6.1.4.1.164.3.1.2.3.5not-accessibleA table.
agnSCmprErrListEntry1.3.6.1.4.1.164.3.1.2.3.5.1not-accessibleAn entry in table.
I32 agnSCmprErrVersion1.3.6.1.4.1.164.3.1.2.3.5.1.1Integer32read-onlyThe version of the compressed data
I32 agnSCmprErrIdx1.3.6.1.4.1.164.3.1.2.3.5.1.2Integer32read-onlyUnique number to identify an entry in the errors list table. The maximum entry value cannot exceed the value of 'agnSNoOfSanityCheckErr'.
OCT agnSCmprErrObj1.3.6.1.4.1.164.3.1.2.3.5.1.3OCTET STRINGread-onlyThis attribute is a full text description of the error, including: error code, slot and port numbers related to the code .
agnTsCmprTable1.3.6.1.4.1.164.3.1.2.3.6not-accessibleA table.
agnTsCmprEntry1.3.6.1.4.1.164.3.1.2.3.6.1not-accessibleAn entry in table.
I32 agnTsCmprVerIdx1.3.6.1.4.1.164.3.1.2.3.6.1.1Integer32read-onlyThis object indicates the version of the internal format of the Compressed data.
I32 agnTsCmprCnfgIdx1.3.6.1.4.1.164.3.1.2.3.6.1.2Integer32read-onlyThis object indicates the configuration to which the Compressed information is related. 255=temporary configuration. Set can be performed only to the temporary configuration.
I32 agnTsCmprSlotIdx1.3.6.1.4.1.164.3.1.2.3.6.1.3Integer32read-onlyThis object indicates the Slot to which the Compressed information is related. For MP-2100: IO-1..IO-12 = (5).. (16) For DXC-30 : IO-1..IO-15 = (5).. (19). NA=255.
I32 agnTsCmprPortIdx1.3.6.1.4.1.164.3.1.2.3.6.1.4Integer32read-onlyThis object indicates the Port within the Slot, to which the Compressed information is related. For Port Index see each product's spec.
I32 agnTsCmprPduIdx1.3.6.1.4.1.164.3.1.2.3.6.1.5Integer32read-onlyThis object indicates the PDU index within the same port. That provides for the case when one PDU is not sufficient for all TS Assignment data of the same port.
OCT agnTsCmprData1.3.6.1.4.1.164.3.1.2.3.6.1.6OCTET STRINGread-writeThis object is the compressed information itself. It provides information about all TSs of a port.
agnXCmprTable1.3.6.1.4.1.164.3.1.2.3.7not-accessibleA table.
agnXCmprEntry1.3.6.1.4.1.164.3.1.2.3.7.1not-accessibleAn entry in table.
I32 agnXCmprTypIdx1.3.6.1.4.1.164.3.1.2.3.7.1.1Integer32read-onlyThis attribute indicates the Type of the Compressed being referred. One of the types is V5.1 Variant data.
I32 agnXCmprVersion1.3.6.1.4.1.164.3.1.2.3.7.1.2Integer32read-onlyThis attribute indicates the version of the internal format of the Compressed data.
I32 agnXCmprIdx31.3.6.1.4.1.164.3.1.2.3.7.1.3Integer32read-only3rd index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant, this attribute indicates the configuration to which the Compressed information is related. 255=temporary configuration. Set can be performed only to the temporary configuration.
I32 agnXCmprIdx41.3.6.1.4.1.164.3.1.2.3.7.1.4Integer32read-only4th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates a unique number of the slot position where the card is inserted. Valid values: psA(1),psB(2),clA(3),clB(4),io1(5)..io12(16); notApplicable=255.
I32 agnXCmprIdx51.3.6.1.4.1.164.3.1.2.3.7.1.5Integer32read-only5th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates a unique identifier of the port the compressed information relates to. Valid values: exPrt1 (1) .. exPrt12 (12) , inPrt1 (101) .. inPrt48 (148).
I32 agnXCmprIdx61.3.6.1.4.1.164.3.1.2.3.7.1.6Integer32read-only6th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates the Variant index. Valid values are: 0..127, 255 (= temp cnfg).Set can be performed only to the temporary configuration.
I32 agnXCmprIdx71.3.6.1.4.1.164.3.1.2.3.7.1.7Integer32read-only7th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute is not needed. Therefore, its value will be always 255=notApplicable.
OCT agnXCmprObj1.3.6.1.4.1.164.3.1.2.3.7.1.8OCTET STRINGread-writeThis attribute is the compressed information itself.
alrBuffGen1.3.6.1.4.1.164.3.1.2.4
alrBufTable1.3.6.1.4.1.164.3.1.2.4.1not-accessibleA table.
alrBufEntry1.3.6.1.4.1.164.3.1.2.4.1.1not-accessibleAn entry in table.
I32 alrBufIdx1.3.6.1.4.1.164.3.1.2.4.1.1.1Integer32read-onlyThis attribute indicates a unique number to identify this entry
STR alrBufDescription1.3.6.1.4.1.164.3.1.2.4.1.1.2DisplayStringread-onlyThis entry is a unique text description of the alarm in the buffer. The alarm description includes the following information: alarm code, slot id, card type, channel id , alarm text, alarm status, masked flag and event counter
U32 alrBufCode1.3.6.1.4.1.164.3.1.2.4.1.1.3Unsigned32read-onlyA code identifying the alarm of an entry in the alarm buffer table.
INT alrBufSlot1.3.6.1.4.1.164.3.1.2.4.1.1.4INTEGERread-onlyThe slot number this alarm refers to. When the alarm refers to a system alarm, the value will be 'notApplicable(255)'.
U32 alrBufPort1.3.6.1.4.1.164.3.1.2.4.1.1.5Unsigned32read-onlyThe port number this alarm refers to. If the port number is irrelevant to this alarm (if it is a system/card level alarm) the value will be 9999.
INT alrBufSeverity1.3.6.1.4.1.164.3.1.2.4.1.1.6INTEGERread-onlyThe severity of the alarm.
INT alrBufState1.3.6.1.4.1.164.3.1.2.4.1.1.7INTEGERread-onlyState of the alarm (On/Off).
INT alrBufferClearCmd1.3.6.1.4.1.164.3.1.2.4.2INTEGERread-writeSetting this attribute to ON, will enforce a clear operation on the Alarms Buffer. Upon completion, the value will automatically change to off(2). For MP-2100/2200, this command will not really erase the Alarm Buffer, but is only an ACK of seeing the Buffer. It marks a pointer of the last entry's alrBufIdx, in order to allow view of new alarms entered after this pointer (alrBufIdxUponLastAck).
U32 alrBufIdxUponLastAck1.3.6.1.4.1.164.3.1.2.4.3Unsigned32read-onlyThis attribute indicates the value of alrBufIdx for the last existing entry of alrBufTable, when alrBufferClearCmd was last Set to on(3). That will enable a user to see only Alarms that entered the alrBufTable after last Set of alrBufferClearCmd, by GetNext of alrBufDescription with this index.
agnFlipDb1.3.6.1.4.1.164.3.1.2.5
agnCAgendaTable1.3.6.1.4.1.164.3.1.2.5.1not-accessibleThis table devides the week days into categories needed for DB flip consideration.
agnCAgendaEntry1.3.6.1.4.1.164.3.1.2.5.1.1not-accessibleAn entry in table.
INT agnCAgendaCnfgIdx1.3.6.1.4.1.164.3.1.2.5.1.1.1INTEGERread-onlyActive or Temporary Agenda Table. Both configurations can be read but only the Temporary can be written to.
INT agnCAgendaDayIdx1.3.6.1.4.1.164.3.1.2.5.1.1.2INTEGERread-onlyDay of week
INT agnCAgendaDayCategory1.3.6.1.4.1.164.3.1.2.5.1.1.3INTEGERread-writeThe Category of the Day
agnCFlipNetEventsTable1.3.6.1.4.1.164.3.1.2.5.2not-accessibleThis table holds the Net Events the MUX should trace
agnCFlipNetEventsEntry1.3.6.1.4.1.164.3.1.2.5.2.1not-accessibleAn entry in table.
INT agnCFlipNetEventsCnfgIdx1.3.6.1.4.1.164.3.1.2.5.2.1.1INTEGERread-onlyActive or Temporary Net Events Table. Both configurations can be read but only the Temporary can be written to.
I32 agnCFlipNetEventIdx1.3.6.1.4.1.164.3.1.2.5.2.1.2Integer32read-onlyEntry within the table
INT agnCFlipNetEventActive1.3.6.1.4.1.164.3.1.2.5.2.1.3INTEGERread-writeIndicates if the entry is valid. In order to Add/Modify parameters of an entry, this object should be set to Yes. In order to delete an entry, this object should be Set to No.
INT agnCFlipNetEventType1.3.6.1.4.1.164.3.1.2.5.2.1.4INTEGERread-writeThe Net Event type
I32 agnCFlipNetEventNo1.3.6.1.4.1.164.3.1.2.5.2.1.5Integer32read-writeThe Net Event No. (Bit Index)
INT agnCFlipNetEventSlot1.3.6.1.4.1.164.3.1.2.5.2.1.6INTEGERread-writeThe slot to which the net event relates . Not applicable for time event
I32 agnCFlipNetEventPort1.3.6.1.4.1.164.3.1.2.5.2.1.7Integer32read-writeThe port within the relevant slot. Valid values: - extPrt1(1)..exPrt16(16) - notApplicable(100) - inPrt1(101)..inPrt84(184)
I32 agnCFlipNetEventISD1.3.6.1.4.1.164.3.1.2.5.2.1.8Integer32read-writeThe time in seconds since the Net Event was reported as ON until it is considered as ON. Not relevant for time events.
I32 agnCFlipNetEventOSD1.3.6.1.4.1.164.3.1.2.5.2.1.9Integer32read-writeThe time in seconds since the net event was reported as OFF until it is considered as OFF. Not relevant for time events.
INT agnCFlipNetEventDayType1.3.6.1.4.1.164.3.1.2.5.2.1.10INTEGERread-writeThe time event relates to all days defined in this category in the agnCAgendaTable. Applicable only for time event
STR agnCFlipNetEventStartTime1.3.6.1.4.1.164.3.1.2.5.2.1.11DisplayStringread-writeThe time event will be activated at this time. The format is hh:mm.
STR agnCFlipNetEventEndTime1.3.6.1.4.1.164.3.1.2.5.2.1.12DisplayStringread-writeThe time event will be deactivated at this time. The format is hh:mm.
agnCFlipTable1.3.6.1.4.1.164.3.1.2.5.3not-accessibleThe DB Flip Decisions Table
agnCFlipEntry1.3.6.1.4.1.164.3.1.2.5.3.1not-accessibleAn entry in table.
INT agnCFlipCnfgIdx1.3.6.1.4.1.164.3.1.2.5.3.1.1INTEGERread-onlyActive or Temporary Flip Decisions Table. Both configurations can be read but only the Temporary can be written to.
I32 agnCFlipIdx1.3.6.1.4.1.164.3.1.2.5.3.1.2Integer32read-onlyEntry number within the table
INT agnCFlipActive1.3.6.1.4.1.164.3.1.2.5.3.1.3INTEGERread-writeIndicates if the entry is valid. In order to Add/Modify parameters of an entry this object should be Set to Yes. In order to delete an entry, this object should be Set to No.
STR agnCFlipLogicalExp1.3.6.1.4.1.164.3.1.2.5.3.1.4DisplayStringread-writeA logical expression composed of events numbers (which were configured in the 'AgnCFlipNetEvantsTable') and logical operators ('|', '&', '!', '(', ')') between them. e.g - (1 & !2) | (121 & 230)
I32 agnCFlipDbNo1.3.6.1.4.1.164.3.1.2.5.3.1.5Integer32read-writeThe ID of the required DB
INT agnCFlipDiscardDe1.3.6.1.4.1.164.3.1.2.5.3.1.6INTEGERread-writeIndicates whether the Mux should start discarding all DE. (MP3000 Only).
agnFlipDbControls1.3.6.1.4.1.164.3.1.2.5.4
INT agnCFlipDbSanityCheckCmd1.3.6.1.4.1.164.3.1.2.5.4.1INTEGERread-writeSetting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and automatically be changed to off(2).
INT agnCSaveFlipDbCmd1.3.6.1.4.1.164.3.1.2.5.4.2INTEGERread-writeSetting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and if it is OK, it will save the Flip Db in the NVRAM, activating the new Flip DB . If check detects errors, the save will not be performed. Afterwards, the object's value will change automatically to off(2).
I32 agnCSaveNetCnfgIdxCmd1.3.6.1.4.1.164.3.1.2.5.4.3Integer32read-writeThis attribute specifies the Id of the target NVRAM Cnfg to which the TmpCnfg should be transferred. Upon set command the MUX will initiate the Sanity-Check process first. If successful, the actual transfer will be performed. If warnings are detected, the user will have to perform the command again to confirm the operation. Setting this object a second time to the same value without performing any change in the database, will cause the result: agnSSanityCheckStatus = unknown. This attribute doesn't cause actual Flip.
INT agnCSaveNetFlipDbCmd1.3.6.1.4.1.164.3.1.2.5.4.4INTEGERread-writeSetting this attribute to on(3) will save the Temp Flip DB Into the NVRAM without actual flip.
INT agnCNetGoCmd1.3.6.1.4.1.164.3.1.2.5.4.5INTEGERread-writeSetting this attribute to On will broadcast a 'GO' command to the network. When a Mux receives a 'GO' command it issues a delay for 'agnCNetDelay' seconds and then activates the DB which was pre-defined by one of the commands : 'agnCSaveNetCnfgIdxCmd' or 'agnCSaveNetFlipDbCmd'.
I32 agnCNetDelay1.3.6.1.4.1.164.3.1.2.5.4.6Integer32read-writeThis attribute determines the period of time in seconds that takes for a message to be transferred over all the network. After a 'GO' command the MUX issues a delay of 'agnCNetDelay' before activating the appropriate DB. The delay will be applied only after performing agnCSaveFlipDbCmd.
INT agnCNetEventsBcast1.3.6.1.4.1.164.3.1.2.5.4.7INTEGERread-writeThis object determines if the Net Events will be Broadcasted to other Muxes of the Net or not. disabled - Net Events will NOT be Broadcasted enabled - Net Events will be Broadcasted. Default=disabled. The value will be applied only after performing agnCSaveFlipDbCmd.
I32 agnCNetEventsBcastInterval1.3.6.1.4.1.164.3.1.2.5.4.8Integer32read-writeWhen agnCNetEventsBcast is enabled, this object determines the interval of time in seconds, between two consecutive Net Events transferred over the network. Default=40 sec. The interval will be applied only after performing agnCSaveFlipDbCmd.
agnSa1.3.6.1.4.1.164.3.1.2.6
I32 agnSaSwchStatus1.3.6.1.4.1.164.3.1.2.6.1Integer32read-onlyThis object indicates the status of the switches on the stand-alone unit. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits: bit 0 NMS (LSB) bit 1 Terminal '1' = forces the DCE to be terminal with Rate=9600bps, Data bits=8, Stop bits=1 bit 2 Xray bit 3 SW-Load '1' = when SW is loaded bit 4 DBS Default of all bits=0 When the status of these switches is unknown, the value of this object is 255.
agnListDecoding1.3.6.1.4.1.164.3.1.2.7
agnListDecodingTable1.3.6.1.4.1.164.3.1.2.7.1not-accessibleA decoding table . For each type of list, a description is given for each existing code.
agnListDecodingEntry1.3.6.1.4.1.164.3.1.2.7.1.1not-accessibleAn entry in table.
INT agnListDecodingType1.3.6.1.4.1.164.3.1.2.7.1.1.1INTEGERread-onlyThe type of list the decoding data refers to. alr - Alarms list sanity - Sanity Check Error list. counter - Counter type of ifPerfCounterType
I32 agnListDecodingCode1.3.6.1.4.1.164.3.1.2.7.1.1.2Integer32read-onlyThe specific code for which decoding is needed.
STR agnListDecodingDescription1.3.6.1.4.1.164.3.1.2.7.1.1.3DisplayStringread-onlyThe description fitting the specific code and type of list required.
INT agnListDecodingDefState1.3.6.1.4.1.164.3.1.2.7.1.1.4INTEGERread-onlyThis object is applicable only for agnListDecodingType=alr. It reports the default state/severity of each alarm. User can change the severity of the alarms defined by this default via the agnListDecodingSeverity object.
INT agnListDecodingSeverity1.3.6.1.4.1.164.3.1.2.7.1.1.5INTEGERread-writeThis object is applicable only for agnListDecodingType=alr. It enables the user to select a severity for each alarm. The severity is set per alarm code (same for all slots/ports using this code). event - can be set only for an alarm that is defined by default as 'event'. User can change the severity of the alarms defined by default as minor or major. The severity of an event may be set to another severity, but the change will actually happen only if the event threshold is active and passed the Set/ON condition. An event alarm that passed the threshold and changed its severity, will return automatically to event severity when meeting its Reset/OFF condition.
INT agnListDecodingAcmRelaySlt1.3.6.1.4.1.164.3.1.2.7.1.1.6INTEGERread-writeThis object indicates the ACM slot, desired for outbound relay (report) for the selected alarm. In the ?004 Unit the entries io6(10)..io12(16) are not valid. none - when agnListDecodingType=alr AND the selected alarm should not be reported by an ACM card. notApplicable - when agnListDecodingType=sanity OR when [agnListDecodingType=alr and there is no ACM card installed in the Mux].
INT agnListDecodingAcmRelayPrt1.3.6.1.4.1.164.3.1.2.7.1.1.7INTEGERread-writeThis object indicates the ACM port within the slot, desired for outbound relay (report) for the selected alarm. notApplicable - when agnListDecodingType=sanity OR when agnListDecodingAcmRelaySlt=notApplicable.
agnSystemDlci1.3.6.1.4.1.164.3.1.2.8
agnDlciTable1.3.6.1.4.1.164.3.1.2.8.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
agnDlciEntry1.3.6.1.4.1.164.3.1.2.8.1.1not-accessibleAn entry in table.
I32 agnDlciCnfgIdx1.3.6.1.4.1.164.3.1.2.8.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT agnDlciLSltIdx1.3.6.1.4.1.164.3.1.2.8.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. This is the Source Slot of the DLCI. vs=Voice Switching In the ?004 Unit the entries io6(10)..io16) are not valid. For ISDN BRI ports of MX300/30 units: io1(5) = isdn1(5) and io2(6) = isdn2(6) LSlotIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx.
I32 agnDlciLPrtIdx1.3.6.1.4.1.164.3.1.2.8.1.1.3Integer32read-onlyThis attribute indicates a unique external or internal port number, including linkSelector or encapsulator. This is the Source Port of the DLCI. 100=noConnect (for voice switching) LPrtIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx.
I32 agnDlciLIdx1.3.6.1.4.1.164.3.1.2.8.1.1.4Integer32read-onlyThis attribute indicates a unique index for each possible used DLCI(16..991). This is the Source Side of the DLCI. 0=notApplicable (for voice switching) LIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx.
INT agnDlciHSltIdx1.3.6.1.4.1.164.3.1.2.8.1.1.5INTEGERread-onlyThis attribute indicates a unique slot position In the Mux where the DLCI is routed to - Destination Slot. For ISDN BRI ports of MX300/30 units: io1(5) = isdn1(5) and io2(6) = isdn2(6) In the ?004 Unit the entries io6(10)..io16) are not valid
I32 agnDlciHPrtIdx1.3.6.1.4.1.164.3.1.2.8.1.1.6Integer32read-onlyThis attribute indicates a unique port number where the DLCI is routed to - Destination Port.
I32 agnDlciHIdx1.3.6.1.4.1.164.3.1.2.8.1.1.7Integer32read-onlyThis attribute indicates a unique internal connection DLCI number where the Source DLCI is routed to - the Destination Side of the DLCI.
INT agnDlciTxBc1.3.6.1.4.1.164.3.1.2.8.1.1.8INTEGERread-createThis attribute indicates a unique Tx committed bandwidth on the user transmit line or at the port receive line.
INT agnDlciTxBe1.3.6.1.4.1.164.3.1.2.8.1.1.9INTEGERread-createThis attribute indicates a unique Tx excess bandwidth on the user transmit line or at the port receive line.
INT agnDlciRxBc1.3.6.1.4.1.164.3.1.2.8.1.1.10INTEGERread-createThis attribute indicates a unique Rx committed bandwidth on the user receive line or at the port transmit line.
INT agnDlciRxBe1.3.6.1.4.1.164.3.1.2.8.1.1.11INTEGERread-createThis attribute indicates a unique Rx excess bandwidth on the user receive line or at the port transmit line.
I32 agnDlciPriority1.3.6.1.4.1.164.3.1.2.8.1.1.12Integer32read-createThis attribute indicates a unique priority of the pcv. 1 is the lowest priority and 7 is the highest priority.
INT agnDlciStatus1.3.6.1.4.1.164.3.1.2.8.1.1.13INTEGERread-onlyThis attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
INT agnDlciSpoofing1.3.6.1.4.1.164.3.1.2.8.1.1.14INTEGERread-createThis object refers to sending of RIP messages: - yes : RIP messages will be sent ONLY if there is a change in the Net. - no : RIP messages will be always sent. This object is relevant only when one side of the DLCI is a CL-NMS interface. Default=no.
INT agnDlciFunnelEnable1.3.6.1.4.1.164.3.1.2.8.1.1.15INTEGERread-createThis object selects Funnel activation: - disabled: Funnel operation will be disabled. The agnDlciTxBe and agnDlciTxBc values are not used for funneling. - enabled : Funnel operation will be enabled both for Source and Destination of the DLCI. The agnDlciTxBe and agnDlciTxBc values are used for funneling calculations. - source: Funnel operation will be enabled only for the Source of the DLCI. - destination:Funnel operation will be enabled only for the Destination of the DLCI. This object is relevant only for an encapsulating DLCI. In case of a Link Selector DLCI, the agnDlciTxBe and agnDlciTxBc values are used for bandwidth of Link Selector. Default=disabled.
INT agnDlciRoutingProtocol1.3.6.1.4.1.164.3.1.2.8.1.1.16INTEGERread-createThis object is relevant only when one side of the DLCI is a CL-NMS interface. It defines which Routing Protocol will be used for management via CL-NMS port. notApplicable will be used for all slots but CL. rip is a proprietary rip protocol. Default=rip.
ROW agnDlciRowStatus1.3.6.1.4.1.164.3.1.2.8.1.1.17RowStatusread-createThis attribute allows to create/delete a row in this table. For creating a row, the NMS should set agnRowStatus.255.id2.id3.id4.id5.id6.id7 = active(1). For destroying a row, the NMS should set: agnRowStatus.255.id2.id3.id4.id5.id6.id7 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
agnVoiceSwitching1.3.6.1.4.1.164.3.1.2.9
agnVoiceSwConfTable1.3.6.1.4.1.164.3.1.2.9.1not-accessibleMXcess Configuration for Voice Switching.
agnVoiceSwConfEntry1.3.6.1.4.1.164.3.1.2.9.1.1not-accessibleAn entry in table.
INT agnVoiceSwConfIdx1.3.6.1.4.1.164.3.1.2.9.1.1.1INTEGERread-onlyActive or Temporary Table. Both configurations can be read but only the Temporary can be written to.
STR agnVoiceSwConfZoneId1.3.6.1.4.1.164.3.1.2.9.1.1.2DisplayStringread-write1 or 2 digits, (0-9)(1-9).
STR agnVoiceSwConfNodeId1.3.6.1.4.1.164.3.1.2.9.1.1.3DisplayStringread-write1, 2 or 3 digits, (1-9),(0-9),(0-9).
I32 agnVoiceSwConfNoOfHops1.3.6.1.4.1.164.3.1.2.9.1.1.4Integer32read-writeNumber of hops the frame will go through the net before deciding to discard the frame (like time-to-live in IP). 0 = notApplicable Default=20 .
I32 agnVoiceSwConfSidt1.3.6.1.4.1.164.3.1.2.9.1.1.5Integer32read-writeSIDT: Short Inter Digit Timeout used as timer (in sec.) between digits after routing is completed. The timeout indicates end of dialing and the call can then be setup. 0 = notApplicable Default=2 sec.
I32 agnVoiceSwConfLidt1.3.6.1.4.1.164.3.1.2.9.1.1.6Integer32read-writeLIDT: Long Inter Digit Timeout used as timer between digits before routing is completed. If no digits were dialed and LIDT expired then the user will get an error tone and the call will be disconnected. 0 = notApplicable Default=15 sec.
INT agnVoiceSwConfDialPlan1.3.6.1.4.1.164.3.1.2.9.1.1.7INTEGERread-writeThis is the Dialing Plan method that will be used in the Voice Switching. Static Dialing Plan - Routing is defined by the current device Zone and Node ID in the Network. Static Dialing Plan Plus - Includes the Static Dialing Plan but contains an addition of defining the number of dialed digits. Flexible Dialing Plan - Routing is defined in a flexible form. In this plan the user can configure the extension number of a local voice channel, Route a call to a remote destination and enter the Number of Digits for a specific dial prefix.
agnVoiceSwConfRtTable1.3.6.1.4.1.164.3.1.2.9.2not-accessibleRouting Table for Voice Switching.
agnVoiceSwConfRtEntry1.3.6.1.4.1.164.3.1.2.9.2.1not-accessibleAn entry in table.
INT agnVoiceSwConfRtDbId1.3.6.1.4.1.164.3.1.2.9.2.1.1INTEGERread-onlyActive or Temporary Table. Both configurations can be read but only the Temporary can be written to.
I32 agnVoiceSwConfRtIdx1.3.6.1.4.1.164.3.1.2.9.2.1.2Integer32read-onlyThe Index of the row.
STR agnVoiceSwConfRtDigits1.3.6.1.4.1.164.3.1.2.9.2.1.3DisplayStringread-createDialed digits: Series of digits 0...9, '*', '#' or '%'. The '*' and '#' can have many uses according to the user's decision. For example, they can be used as part of the Dialed Number, they exist on the phone number panel. '*' can also be used instead of a series of numbers. The '%' means any digits (wildcard) and is used without a series of digits. When the agnVoiceSwConfRtAction is del (7), the series of digits that are configured via this MIB object will be deleted from the prefix of the dialed number.
INT agnVoiceSwConfRtAction1.3.6.1.4.1.164.3.1.2.9.2.1.4INTEGERread-createAction that the system should perform for the digits: agnVoiceSwConfRtDigits. The action that is allowed depends on the Dialing Plan. Here is the list of the allowed actions: For Static Dialing Plan - zone, node, in, shortDialing, hgr, del, rep For Static Dialing Plan Plus - zone, node, in, shortDialing, hgr, del, rep, numDigDP For Flexible Dialing Plan - hgr, del, rep, numDigDP, route, ext
STR agnVoiceSwConfRtData1.3.6.1.4.1.164.3.1.2.9.2.1.5DisplayStringread-createThis field is relevant for actions hgr(6), and rep(8), numDigDP(11) and contains the following information: For hgr - the number of the Hunt Group. For rep - the number of digits to be replaced with. For numDigDP - the number of digits collected before establishing the call. 0 indicates no defined length. In this case SIDT will be used.
INT agnVoiceSwConfRtSlot1.3.6.1.4.1.164.3.1.2.9.2.1.6INTEGERread-createRouting Slot- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13).
I32 agnVoiceSwConfRtPort1.3.6.1.4.1.164.3.1.2.9.2.1.7Integer32read-createRouting Port- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13). 100=noConnect (for non-routing case).
I32 agnVoiceSwConfRtDlci1.3.6.1.4.1.164.3.1.2.9.2.1.8Integer32read-createRouting DLCI- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13). Valid values: 0=notApplicable (for non-routing case). 1, 16..991
ROW agnVoiceSwConfRtRowStatus1.3.6.1.4.1.164.3.1.2.9.2.1.9RowStatusread-createStatus of the row for creating/deleting entries in the table. The only possible supported RowStatus vaules are active (1), notInService (2), notReady(3), createAndGo(4), createAndWait(5) and destroy(6).
I32 agnVoiceSwConfRtMaxCalls1.3.6.1.4.1.164.3.1.2.9.2.1.10Integer32read-createMaximum no. of simultaneous voice calls that are allowed in the direction defined by the current entry. Default=0 (No Limit).
I32 agnVoiceSwConfRtPriority1.3.6.1.4.1.164.3.1.2.9.2.1.11Integer32read-createThis attribute indicates a unique priority of the Voice Switching Route. 1 is the lowest priority and 7 is the highest priority. 0 means N/A
agnVoiceSwConfHGTable1.3.6.1.4.1.164.3.1.2.9.5not-accessibleTable of Hunt Groups.
agnVoiceSwConfHGEntry1.3.6.1.4.1.164.3.1.2.9.5.1not-accessibleAn entry in table.
INT agnVoiceSwConfHGdbIdx1.3.6.1.4.1.164.3.1.2.9.5.1.1INTEGERread-onlyActive or Temporary Table. Both configurations can be read but only the Temporary can be written to.
I32 agnVoiceSwConfHGIdx1.3.6.1.4.1.164.3.1.2.9.5.1.2Integer32read-onlyFor Vmux-300 devices - This object represents a combination of - Hunt Group number and Extension number OR - Port number and Extension number. For other devices (e.g. MXcess, MP-2100H) - There may be up to 10 Hunt Groups per MXcess. That's the index of the hunt group relevant to this row.
INT agnVoiceSwConfHGConnect1.3.6.1.4.1.164.3.1.2.9.5.1.3INTEGERread-writeThis attribute indicates whether the hunt group should be considered in any of the mux algorithms.
I32 agnVoiceSwConfHGExt1.3.6.1.4.1.164.3.1.2.9.5.1.4Integer32read-writeThis is the extension number of the hunt group. 0 is for not valid. The allowed range is 10 - 99.
STR agnVoiceSwConfHGExtString1.3.6.1.4.1.164.3.1.2.9.5.1.5SnmpAdminStringread-writeThis is the extension string of the hunt group. This string is a combination of digits, * and #.
STR agnVoiceSwConfHGUserParams1.3.6.1.4.1.164.3.1.2.9.5.1.6SnmpAdminStringread-writeThis object indicates the User's parameters.
INT agnVoiceSwConfHGStatus1.3.6.1.4.1.164.3.1.2.9.5.1.7INTEGERread-writeThis object enables the user to create/delete entries in this table. Its usage for values (1)..(6) should be identical to RowStatus SYNTAX. notApplicable(255) - should be used when the table is static (i.e. whenever create/delete entries is not allowed).
agnSigProfile1.3.6.1.4.1.164.3.1.2.10
agnSigProfileTable1.3.6.1.4.1.164.3.1.2.10.1not-accessible- For products supporting more than one configuration, the write operation into the Table is valid only to the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table will be to agnSigProfileCnfgIdx=1. The table includes signaling profile parameters for Legacy Profiles.
agnSigProfileEntry1.3.6.1.4.1.164.3.1.2.10.1.1not-accessibleAn entry in table.
I32 agnSigProfileCnfgIdx1.3.6.1.4.1.164.3.1.2.10.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. For products supporting more than one configuration,the write operation is valid only to the TmpCnfg. For Gmux2000 the range limitation (1..255) was discarded since the Idx is computed as: x 1000 + 255.
I32 agnSigProfileIdx1.3.6.1.4.1.164.3.1.2.10.1.1.2Integer32read-onlyThis attribute indicates the Signaling Profile (1..5). For MP-104/204, only Profile=1 will exist.
INT agnSigProfileRxTx1.3.6.1.4.1.164.3.1.2.10.1.1.3INTEGERread-onlyThis attribute indicates if the following objects refer to: Rx or Tx translation. Rx : ML->IO Tx : IO->ML . For MP-104/204, that means: Rx : Signaling to FXS CH Tx : Signaling to E1 Link.
OCT agnSigProfileABCD1.3.6.1.4.1.164.3.1.2.10.1.1.4OCTET STRINGread-writeFor MP-2100/MP-2200 and for MP-104/204 from R2: This object represents 6 parameters, by 3 Octets : Busy Code-MSB nibble, - applicable only for Rx translation Idle Code- nibble, - applicable only for Rx translation D Bit Code- nibble, C Bit Code- nibble, B Bit Code- nibble, A Bit Code-LSB nibble. Each of Busy and Idle Code nibble will have the valid values: 0000 .. FFFF. Each of A,B,C,D Bit Code nibble represents: 0 hex = 0000 = 0 1 hex = 0001 = 1 2 hex = 0010 = A bit 3 hex = 0011 = B bit 4 hex = 0100 = C bit 5 hex = 0101 = D bit 6 hex = 0110 = A bit inverse 7 hex = 0111 = B bit inverse 8 hex = 1000 = C bit inverse 9 hex = 1001 = D bit inverse A-F hex - not used (invalid values) For MP-104/204 R1: This object represents 3 parameters, by 2 Octets : Bit 1 = Bit A - OFF Hook for Tx ; Ring for Rx (LSB) Bit 2 = Bit B - OFF Hook for Tx ; Ring for Rx Bit 3 = Bit C - OFF Hook for Tx ; Ring for Rx Bit 4 = Bit D - OFF Hook for Tx ; Ring for Rx Bit 5 = Bit A - ON Hook for Tx ; Idle for Rx Bit 6 = Bit B - ON Hook for Tx ; Idle for Rx Bit 7 = Bit C - ON Hook for Tx ; Idle for Rx Bit 8 = Bit D - ON Hook for Tx ; Idle for Rx Bit 9 = Bit A - OOS State for both Tx and Rx Bit 10 = Bit B - OOS State for both Tx and Rx Bit 11 = Bit C - OOS State for both Tx and Rx Bit 12 = Bit D - OOS State for both Tx and Rx Bit 13 = Spare (always 0) Bit 14 = Spare (always 0) Bit 15 = Spare (always 0) Bit 16 = Spare (always 0) (MSB) When the object is not applicable, the Octet String will have 0 bytes.
agnSigProfTable1.3.6.1.4.1.164.3.1.2.10.2not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry. This is the general table of signaling profiles.
agnSigProfEntry1.3.6.1.4.1.164.3.1.2.10.2.1not-accessibleAn entry in table.
I32 agnSigProfCnfgIdx1.3.6.1.4.1.164.3.1.2.10.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
I32 agnSigProfIdx1.3.6.1.4.1.164.3.1.2.10.2.1.2Integer32read-onlyThis attribute indicates the Signaling Profile (1..5).
STR agnSigProfName1.3.6.1.4.1.164.3.1.2.10.2.1.3DisplayStringread-writeProfile Name given by user.
INT agnSigProfType1.3.6.1.4.1.164.3.1.2.10.2.1.4INTEGERread-writeProfile Type. legacy - usual signaling. The parameters for the Legacy Profiles are detailed in the agnSigProfileTable, above. r2Cas - R2 signaling. The parameters for the R2 Profiles are detailed in the r2 ProfileCnfg tables (belong to r2If).
agnSystemTs1.3.6.1.4.1.164.3.1.2.11
systemVoice1.3.6.1.4.1.164.3.1.2.12
systemVoiceTable1.3.6.1.4.1.164.3.1.2.12.1not-accessibleGeneral Parameters for voice - system level.
systemVoiceEntry1.3.6.1.4.1.164.3.1.2.12.1.1not-accessibleAn entry in table.
I32 systemVoiceConfIdx1.3.6.1.4.1.164.3.1.2.12.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed - Active or Temporary Configurations. Idx 255 relates to the temporary TmpCnfg. All configurations can be read but only the Temporary can be written to.
INT systemVoiceNationalTone1.3.6.1.4.1.164.3.1.2.12.1.1.2INTEGERread-writeTone Characteristics (Amplitude, Frequency, delays etc.). These characteristics are defined according to the country.
U32 systemVoicePacketRate1.3.6.1.4.1.164.3.1.2.12.1.1.3Unsigned32read-writeThis object indicates the G.729 and G.711 Coders transmitted Packet Rate in milliseconds.
INT systemVoiceFaxSupport1.3.6.1.4.1.164.3.1.2.12.1.1.4INTEGERread-writeThis object allows the user to Disable/Enable Fax support.
INT systemVoiceFaxRate1.3.6.1.4.1.164.3.1.2.12.1.1.5INTEGERread-writeThis object indicates the Fax Rate limit. It is irrelevant when Fax support is NA or disabled.
INT systemVoiceModemSupport1.3.6.1.4.1.164.3.1.2.12.1.1.6INTEGERread-writeThis object allows the user to Disable/Enable Modem support.
INT systemVoiceCoderAndRate1.3.6.1.4.1.164.3.1.2.12.1.1.7INTEGERread-writeThis object indicates the Coder and Rate for the Voice Compression.
INT systemVoiceEchoCanceler1.3.6.1.4.1.164.3.1.2.12.1.1.8INTEGERread-writeThis object indicates the Echo Canceler activation.
I32 systemVoiceTxGain1.3.6.1.4.1.164.3.1.2.12.1.1.9Integer32read-writeThis object indicates the Transmit Gain (volume) in dB.
INT systemVoiceDtmfRelayMethod1.3.6.1.4.1.164.3.1.2.12.1.1.10INTEGERread-writeThis object indicates the DTMF Relay Method that is used to transmit DTMF tones. rfc2833(1) - inband DTMF relay according to RFC-2833. sipInfo(2) - out of band DTMF relay using SIP INFO method.
U32 systemVoiceDtmfRelayRxPayloadType1.3.6.1.4.1.164.3.1.2.12.1.1.11Unsigned32read-writeThis object indicates the Rx Payload Type for DTMF relay RTP packets. It is relevant only when DTMF Relay Method is RFC-2833.
INT systemVoiceDtmfRelayPayloadTypeNeg1.3.6.1.4.1.164.3.1.2.12.1.1.12INTEGERread-writeThis object indicates whether Payload Type Negotiation is used (according to RFC-2833) or not. It is relevant only when DTMF Relay Method is RFC-2833.
U32 systemVoiceDtmfRelayTxPayloadType1.3.6.1.4.1.164.3.1.2.12.1.1.13Unsigned32read-writeThis object indicates the Tx Payload Type for DTMF relay RTP packets. It is relevant only when the Payload Type Negotiation is disabled.
systemVoiceCoderTable1.3.6.1.4.1.164.3.1.2.12.2not-accessibleVoice Coders table.
systemVoiceCoderEntry1.3.6.1.4.1.164.3.1.2.12.2.1not-accessibleAn entry in Voice Coders table.
U32 systemVoiceCoderConfIdx1.3.6.1.4.1.164.3.1.2.12.2.1.1Unsigned32not-accessibleThe first index of the table. This object might represent the Configuration Index (1..100) being accessed; Index=255 relates to the TmpCnfg. For devices with multiple configurations, Set is permitted to TmpCnfg(255) only. Not-Applicable = 1.
U32 systemVoiceCoderPriority1.3.6.1.4.1.164.3.1.2.12.2.1.2Unsigned32not-accessibleThis object indicates the Coder's Priority.
INT systemVoiceCoderCoderAndRate1.3.6.1.4.1.164.3.1.2.12.2.1.3INTEGERread-writeThis object indicates the Coder and Rate for the Voice Compression.
mdlWanGen1.3.6.1.4.1.164.3.1.3
statMdlGen1.3.6.1.4.1.164.3.1.3.1
mdlSInstTable1.3.6.1.4.1.164.3.1.3.1.1not-accessibleA table.
mdlSInstEntry1.3.6.1.4.1.164.3.1.3.1.1.1not-accessibleAn entry in table.
INT mdlSInstSltIdx1.3.6.1.4.1.164.3.1.3.1.1.1.1INTEGERread-onlyA unique number to identify a slot position in the mux. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid. For the Vmux2100 Main Board clA (3) is used.
INT mdlSInstCardType1.3.6.1.4.1.164.3.1.3.1.1.1.2INTEGERread-onlyThis attribute indicates the type of card installed in the specific slot position. Only PS cards are possible in the PS slots. Only CL cards are possible in the CL slots. Only IO cards are possible in the IO slots.
STR mdlSHwVersion1.3.6.1.4.1.164.3.1.3.1.1.1.3DisplayStringread-onlyThis attribute indicates the Hardware version of the installed card in the specific slot position.
STR mdlSSwVersion1.3.6.1.4.1.164.3.1.3.1.1.1.4DisplayStringread-onlyThis attribute indicates the Software version of the installed card in the specific slot position.
INT mdlSAlrStatus1.3.6.1.4.1.164.3.1.3.1.1.1.5INTEGERread-onlyIndicates the alarm state at module level, i.e. lower level (port alarms) status is not included. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
INT mdlSAlrStatusAll1.3.6.1.4.1.164.3.1.3.1.1.1.6INTEGERread-onlyIndicates the alarm state in the module-all level, i.e. lower level (port alarms) included. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
INT mdlSMaskedAlrStat1.3.6.1.4.1.164.3.1.3.1.1.1.7INTEGERread-onlyIndicates the alarm state at module level, [i.e. lower level (port alarms) status is not included],including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
INT mdlSMaskedAlrStatAll1.3.6.1.4.1.164.3.1.3.1.1.1.8INTEGERread-onlyIndicates the alarm state in the module-all level, i.e. lower level (port alarms) included, including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
INT mdlSTstStatusAll1.3.6.1.4.1.164.3.1.3.1.1.1.9INTEGERread-onlyThis attribute will be set to on(3) when there is at least one test in progress on a channel of the card, otherwise the value will be off(2).
INT mdlSClearAlrCmd1.3.6.1.4.1.164.3.1.3.1.1.1.10INTEGERread-writeSetting this command to ON, enforces a clear of all the alarms in the given slot, excluding alarms of port level. The clear operation will not be applied for masked/inverted alarms.
INT mdlSClearAllAlrCmd1.3.6.1.4.1.164.3.1.3.1.1.1.11INTEGERread-writeSetting this command to ON, enforces a clear of all the alarms in the given slot, including all its ports alarms. The clear operation will not be applied for masked/inverted alarms.
I32 mdlSTemperature1.3.6.1.4.1.164.3.1.3.1.1.1.12Integer32read-onlyTemperature of the card, in Celsius degrees.
mdlSAlrTable1.3.6.1.4.1.164.3.1.3.1.2not-accessibleThe list of card agent alarms ; includes also an alarm indicating existence of alarms on its ports if there are any.
mdlSAlrEntry1.3.6.1.4.1.164.3.1.3.1.2.1not-accessibleAn entry in table.
I32 mdlSAlrIdx1.3.6.1.4.1.164.3.1.3.1.2.1.1Integer32read-onlyA unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive.
INT mdlSAlrSltIdx1.3.6.1.4.1.164.3.1.3.1.2.1.2INTEGERread-onlyThis attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16) are not valid. For the Vmux2100 Main Board clA (3) is used.
STR mdlSAlrCodeDescription1.3.6.1.4.1.164.3.1.3.1.2.1.3DisplayStringread-onlyThis attribute is a full text description of the alarm . The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter.
I32 mdlSAlrCode1.3.6.1.4.1.164.3.1.3.1.2.1.4Integer32read-onlyA code identifying the alarm of an entry in the alarm status table at card level.
INT mdlSAlrSeverity1.3.6.1.4.1.164.3.1.3.1.2.1.5INTEGERread-onlyThe severity of the alarm.
INT mdlSAlrState1.3.6.1.4.1.164.3.1.3.1.2.1.6INTEGERread-onlyState of the alarm.
I32 mdlSAlrCounter1.3.6.1.4.1.164.3.1.3.1.2.1.7Integer32read-onlyA counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately.
INT mdlSAlrMask1.3.6.1.4.1.164.3.1.3.1.2.1.8INTEGERread-onlyAlarm mask : on/off.
INT mdlSAlrInvert1.3.6.1.4.1.164.3.1.3.1.2.1.9INTEGERread-onlyAlarm invert : on/off.
cnfgMdlGen1.3.6.1.4.1.164.3.1.3.2
mdlCPrgTable1.3.6.1.4.1.164.3.1.3.2.1not-accessibleA table.
mdlCPrgEntry1.3.6.1.4.1.164.3.1.3.2.1.1not-accessibleAn entry in table.
I32 mdlCCnfgIdx1.3.6.1.4.1.164.3.1.3.2.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg(1..100) being referred. Value 255 specifies the TmpCnfg
INT mdlCSltIdx1.3.6.1.4.1.164.3.1.3.2.1.1.2INTEGERread-onlyThis attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
INT mdlCPrgCardType1.3.6.1.4.1.164.3.1.3.2.1.1.3INTEGERread-writeThis attribute indicates the type of card assigned to the specific slot in the common configuration. This object is identical in all the configurations (1..100). Only the TmpCnf(255) may have different value. The write operation is valid only to the TmpCnfg entry.
I32 mdlCNoOfExternPrt1.3.6.1.4.1.164.3.1.3.2.1.1.4Integer32read-onlyNumber of external ports in the programmed card of the specific slot position
I32 mdlCNoOfInternPrt1.3.6.1.4.1.164.3.1.3.2.1.1.5Integer32read-onlyNumber of internal ports in the programmed card of the specific slot position.
INT mdlCWorkMode1.3.6.1.4.1.164.3.1.3.2.1.1.6INTEGERread-writeWorking mode of the card. The user may configure the card to work in a stand alone mode or integrated with the device. Example for use in MHS-IP cards: - standAlone - in this mode, the router works so that data is received via the LAN (Eth) port and is transmitted via the WAN (HS) external port without going through the MPH device. - integrated - in this mode, the router works so that it is integrated in the MPH and routes DLCIs into the device.
INT mdlCDhcpClientEnable1.3.6.1.4.1.164.3.1.3.2.1.1.7INTEGERread-writeEnable/Disable the feature of DHCP Client for the selected card.
INT mdlCRdnExists1.3.6.1.4.1.164.3.1.3.2.1.1.8INTEGERread-onlyThis object indicates whether any port of the programmed card is configured to be part of a Redundancy/APS pair. If at least one port of the programmed card is configured to be part of a Redundancy/APS pair, the value will be 'yes'. Otherwise, it will be 'no'.
OCT mdlCInterfaces1.3.6.1.4.1.164.3.1.3.2.1.1.9OCTET STRINGread-onlyOctet string which indicates 'present' interfaces in card. Each '0' bit stands for non-present interface. Each '1' bit stands for present interface. For ASMi54C card of LRS-102 and MP-4100 notPresent interfaces may be: - SHDSL Line ID with no wire pairs assigned to it (does not exist in ifTable) - PCS without SHDSL Line binded to it, (exist in ifTable, with ifOperStatus= notPresent) - External DS1 when its LIU is used by an Internal DS1 of the same card - Internal DS1 when single bearer is not TDM. In each octet, MS bit represents port 1 and LS bit represents port 8 MSB LSB 1 0 0 0 1 0 0 0 -- Example: Port # 1 and 5 are present. Port 1 2 3 4 5 6 7 8 1st Octet (MSB octet) represents SDHSL Lines 2nd Octet represents PCS 3rd Octet represents External DS1 4th Octet represents Internal DS1 5th and 6th Octets are reserved for future Internal DS1. For OP-108/106 cards of LRS-102 and MP-4100 notPresent interfaces may be: - External DS1 when its 'associated' Int-DS1 port is connected to another card - Internal DS1 when its 'associated' Ext-DS1 port is connected to another card (Both may be 'present' when inter-connected). 1st Octet represents External DS1 2nd Octet represents Internal DS1 Bit representation, same as for ASMi-54C card.
cmprMdlGen1.3.6.1.4.1.164.3.1.3.3
mdlCmprTable1.3.6.1.4.1.164.3.1.3.3.1not-accessibleA table.
mdlCmprEntry1.3.6.1.4.1.164.3.1.3.3.1.1not-accessibleAn entry in table.
I32 mdlCmprTypIdx1.3.6.1.4.1.164.3.1.3.3.1.1.1Integer32read-onlyThis attribute indicates the Type of the Compressed being referred.
I32 mdlCmprCnfgIdx1.3.6.1.4.1.164.3.1.3.3.1.1.2Integer32read-onlyThis attribute indicates the configuration to which the Compressed information is related.
I32 mdlCmprVersion1.3.6.1.4.1.164.3.1.3.3.1.1.3Integer32read-onlyThis attribute indicates the version of the internal format of the Compressed data
INT mdlCmprSltIdx1.3.6.1.4.1.164.3.1.3.3.1.1.4INTEGERread-onlyThis attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
OCT mdlCmprObj1.3.6.1.4.1.164.3.1.3.3.1.1.5OCTET STRINGread-writeThis attribute is the compressed information itself.
mdlAlarmsCmprTable1.3.6.1.4.1.164.3.1.3.3.2not-accessibleA table.
mdlAlarmsCmprEntry1.3.6.1.4.1.164.3.1.3.3.2.1not-accessibleAn entry in table.
I32 mdlAlarmsCmprVersion1.3.6.1.4.1.164.3.1.3.3.2.1.1Integer32read-onlyThis attribute indicates the version of the internal format of the Compressed data
I32 mdlAlarmsCmprAlarmSlot1.3.6.1.4.1.164.3.1.3.3.2.1.2Integer32read-onlyThis attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid.
I32 mdlAlarmsCmprAlarmIdx1.3.6.1.4.1.164.3.1.3.3.2.1.3Integer32read-onlyA unique number to identify an entry in the alarm status table of the agent.
OCT mdlAlarmsCmprObj1.3.6.1.4.1.164.3.1.3.3.2.1.4OCTET STRINGread-writeThis attribute is the compressed information itself.
prtWanGen1.3.6.1.4.1.164.3.1.4
statPrtGen1.3.6.1.4.1.164.3.1.4.1
prtSInstTable1.3.6.1.4.1.164.3.1.4.1.1not-accessibleA table.
prtSInstEntry1.3.6.1.4.1.164.3.1.4.1.1.1not-accessibleAn entry in table.
INT prtSInstSltIdx1.3.6.1.4.1.164.3.1.4.1.1.1.1INTEGERread-onlyThis attribute indicates a unique number to identify the slot where the card is inserted. In the ?004 Unit the entries io6(10)..io(16) are not valid. For the Vmux2100 Main Board clA (3) is used.
I32 prtSInstPrtIdx1.3.6.1.4.1.164.3.1.4.1.1.1.2Integer32read-onlyThis attribute indicates a unique number to identify a port in a specific card. The valid ports depend on the installed card: the valid external ports (interfaces) are (1..mdlCNoOfExternPrt) if any, and the valid internal ports are (101..100+mdlCNoOfInternPrt) if any. Generally, for MP-2100/2200: exPrt1 (1) .. exPrt16 (16),inPrt1(101) .. inPrt48 (148) For the Vmux-2100 device: This index will have values of 1...4 for the physical ports & values of ifIndex for the bundles. For other products, see product's spec.
INT prtSInstPrtType1.3.6.1.4.1.164.3.1.4.1.1.1.3INTEGERread-onlyThis attribute describes the type of the designated port. In MX 3000 only external & internal options are used. All the other options are only for MX 30/300 which need special handling. In order to support interface types in MX 3000, return an ascii string for prtSInterfaceType in this table or support the general RAD value of physicalConnector. External port - is a port with a physical connector. Internal port - might be of two types: a) A composite port which collects a few external ports data into a common bandwidth (usually routed through DS1 link) b) A port which gets only part of the external ports (usually a few DS0's) The following types are used when all ports are external/ internal and the connector/interface type is necessary (for example, stand-alone units): High Speed port types Low Speed port types Voice port types, CL port types. ISDN Voice in MX 30/300 Phase 4: voiceS0 (16), voiceU (17) should be used. ISDN Voice in MX 30/300 Phase 5: voiceQsigS(18), voiceQsigU (19) should be used.
I32 prtSInstIfIndex1.3.6.1.4.1.164.3.1.4.1.1.1.4Integer32read-onlyThis attribute indicates the unique interface number assigned to the port. The specific interface of this attribute is the same as the interface identified by the value of ifindex in MIB-II.If there is no interface for the specific prtIdx the value will be '7fffffff'h.
INT prtSActiveStatus1.3.6.1.4.1.164.3.1.4.1.1.1.5INTEGERread-onlyThis attribute describes the activity status of the port. unknown(1) indicates that the information is not supported. notUsed(2) indicates that the ch is not connected according to the active config. offLine(3) indicates that the ch is down (not working) because of any problem. onLine(4) indicates that the ch is up (working) offLineRedundancy(5) indicates that the ch is down, because it is redundant port. onLineRedundancy(6) indicates that the ch is up, and it is the active link
INT prtSAlrStatus1.3.6.1.4.1.164.3.1.4.1.1.1.6INTEGERread-onlyIndicates the alarm state in the port(ch) agent level. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
INT prtSMaskedAlrStat1.3.6.1.4.1.164.3.1.4.1.1.1.7INTEGERread-onlyIndicates the alarm state in the port(ch) agent level, including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
INT prtSClearAlrCmd1.3.6.1.4.1.164.3.1.4.1.1.1.8INTEGERread-writeSetting this attribute to on(3) enforces a clear operation of the alarm status events in the given port. The clear operation will not be applied for masked/inverted alarms.
I32 prtSTestMask1.3.6.1.4.1.164.3.1.4.1.1.1.9Integer32read-onlyThis is a mask which indicates which tests from the 'prtSTstCmd' list are allowed for the requested port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- local-loop 1 remote-loop 2 loc-and-rem-main-loops 3 remote-analog-loop 4 remote-digital-loop 5 rem-loop-on-ext-unit 6 bert 7 tone-injection 8 dlci local-loop 9 all dlci local-loop 10 dlci remote-loop 11 all dlci remote-loop 12 bert-and-rem-loop-on-rem-unit 13 rem-loop-on-rem-unit 14 block 15 backward-tone-inject 16 llb 17 rlb 18 ft1Enable 21 lbbd 22 --for 2B+D lb1 23 --for B1 lb2 24 --for B2 llb-on-rem-unit 25 bert-on-rem-unit 26 bert-on-rem-and-llb-on-rem-unit 27 local-and-bert-on-rem-unit 28 local-loop-on-rem-unit 29 localBert 30 --towards IO ports test-per-TS 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
INT prtSTstCmd1.3.6.1.4.1.164.3.1.4.1.1.1.10INTEGERread-writeSetting this attribute to any of the above values will initiate a test on the specific port if the operation is legal. If the operation is not legal, the mux will ignore the operation. testPerTS(31) - when this test is selected, the selection of tests for each TS is done via the prtExPh1MlTsTest object. If a test time out is needed, the test will be set with a default timeout of 2 minutes until the user will set the parameter 'prtSTstDuration' to the required time out. If no time out is needed , the test will be set with infinite timeout until the user will set the parameter 'prtSTstDuration' to the required time out.
I32 prtSTstDuration1.3.6.1.4.1.164.3.1.4.1.1.1.11Integer32read-writeThis attribute indicates the maximum duration of executing a test on the specific port. This entry applies to all the test operations. The resolution will be a minute, and the maximum duration is limited to 30 minutes. For Vmux devices, the values are in seconds. A zero value specifies no time limitation. When the test isn't active, the agent initiates this object to 2 when the duration is needed and to 0 if its not required. The user should set this parameter after setting the 'prtSTstCmd' parameter.
INT prtSBertClrCmd1.3.6.1.4.1.164.3.1.4.1.1.1.12INTEGERread-writeSetting this attribute initiates bert count clear operation. It is valid only when bert test is active on the specific port.
I32 prtSBertTstRslt1.3.6.1.4.1.164.3.1.4.1.1.1.13Integer32read-onlyThis attribute indicates the number of Bit Error Rate indicated during the BERT operation. It is valid only when bert test is active on the specific port.
STR prtSInterfaceType1.3.6.1.4.1.164.3.1.4.1.1.1.14DisplayStringread-onlyThis attribute indicates a unique HW interface type of the selected port.
OCT prtSParamStatus1.3.6.1.4.1.164.3.1.4.1.1.1.15OCTET STRINGread-onlyThis object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6, external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - --- CTS DSR DCD RJ TM DTR RTS Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) '---' will always have the value 00 Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For ACM external port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |_________| spare Alarm State Alarm State: according to bits 1,0: 00=NA ; 01=unused ; 10=Off ; 11=On - For HS-U/1 external port - 1 Octet Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For MTML-2/4 external ports, ML-8 externalports, ML-IP (MTML-IP) internal ports and MTML-E2 internal ports - 1 Octet : Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs/Bits) 1 = ON (BERT is running on this port OR on one of its TSs/Bits) - For ML-20N external ports - 4 Octets - 1 MS Octet will represent the Actual Link Rate: Bit - 7 6 5 4 3 2 1 0 |_| |_________| spare Rate Valid values: 0..34, meaning: 0..32 = (0..32)x64Kbps 33 = Invalid Rate 34 = not applicable (when Rate is not Auto) 35 = 0 Kbps Invalid values: 36..255. - 2 middle Octets will represent the Status of 4 Control Signals: - LS Octet - Bits 3-0: RTS/C (Command, for X.21 interface) Bits 7-4: DCD/I (Indication for X.21 interface) - MS Octet - Bits 3-0: DTR Bits 7-4: DSR Each 4 Bits are divided as follows: - 2 MS bits: DCE - 2 LS bits: DTE For each 2 bits (DCE/DTE): 00=NA ; 01=unused ; 10=Off ; 11=On. - LS Octet: (as for MTML-2): Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs/Bits) 1 = ON (BERT is running on this port OR on one of its TSs/Bits) - For MP-2100/2200 MSL-4/E1, MSL-8/E1 External ports - 3 Octets - MS octet: far-end modem channel interface - Middle octet: Material (plastic/metal), far-end modem type, synchronization with far-end modem - LS octet: BERT state (at port/TS/Bit level) - MS octet: 0000 0000 = no interface 0000 0001 = db15 (X21) 0000 0010 = IR-IP 0000 0011 = IR-ETH-Q 0000 0100 = V35 0000 0101 = ETH-RJ45 0000 0110 = G703 0000 0111 = db25 (RS530) 0000 1000 = ETH-BNC 0000 1001 = E1(Balanced) 0000 1010 = E1(Unbalanced) 0000 1011 = IR-ETH-QN Rest of the combinations: reserved - Middle octet: Bit 7 6 5 4 3 2 1 0 LSB | |___________| |__| Box material modem sync Box material modem: 00000 = other sync: 00 = not sync (for ASMi-52 SA) 00001 = unknown 01 = sync 0=metal 00010 = reserved 10 = reserved 1=plastic 00011 = reserved 11 = reserved 00100 = reserved 00101 = reserved 00110 = ASMi-52 SA/2W/Slave 00111 = ASMi-52 SA/2W/Master 01000 = ASMi-52/CQ card of LRS-24 01001 = ASMi-52/CD card of LRS-24 01010 = D16GSDSL card of DXC-3000 01011 = LRS-52 01100 = FCD-IP 01101 = FCD-IPM 01110 = D8SL card of DXC-30 01111 = ASMi-52A 10000 = MP card (SHDSL) 10001 = ASMi-52L Rest = reserved - LS Octet: (as for MTML-2): Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs) 1 = ON (BERT is running on this port OR on one of its TSs) - For MP-4100 MSL card Links - 4 Octets - MS octet: far-end modem DTE2 interface (same as for MP-2100 MSL cards) - after MS octet: far-end modem DTE1 interface (same as for MP-2100 MSL cards) - before LS octet: Material (plastic/metal), far-end modem type, synchronization with far-end modem (same as for MP-2100 MSL cards) - LS octet: BERT state (at port/TS/Bit level)- same as for MP-2100 MSL cards - For MP-4100, LRS-102 OP-108/106 Links - 3 Octets - MS octet: far-end PS type and state - Middle octet: synchronization with far-end device - LS octet: BERT state (at port/TS level) - same as for MP-2100 MSL cards - MS octet: Bit 7 6 5 4 3 2 1 0 LSB |__| |__| |__| |__| PS-A PS-A PS-B PS-B PS Type PS State PS Type PS State 00=None 00=None 01=AC-DC 01=OK 10=DC 10=Fail - Middle octet: Bit 7 6 5 4 3 2 1 0 LSB |__| sync: 00 = not sync 01 = sync 10 = reserved 11 = reserved Rest = reserved
OCT prtSTestMaskXp1.3.6.1.4.1.164.3.1.4.1.1.1.16OCTET STRINGread-writeThis is an Expanded test mask of the prtSTestMask object. The prtSTestMask object reached its maximum, being an Integer with 32 bits. This object indicates which tests from the 'prtSTstCmdXP' list are allowed for the selected port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- local-loop 1 remote-loop 2 loc-and-rem-main-loops 3 remote-analog-loop 4 remote-digital-loop 5 rem-loop-on-ext-unit 6 bert 7 tone-injection 8 dlci local-loop 9 all dlci local-loop 10 dlci remote-loop 11 all dlci remote-loop 12 bert-and-rem-loop-on-rem-unit 13 rem-loop-on-rem-unit 14 block 15 backward-tone-inject 16 llb 17 rlb 18 ft1Enable 21 lbbd 22 --for 2B+D lb1 23 --for B1 lb2 24 --for B2 llb-on-rem-unit 25 bert-on-rem-unit 26 bert-on-rem-and-llb-on-rem-unit 27 local-and-bert-on-rem-unit 28 local-loop-on-rem-unit 29 localBert 30 --towards IO ports test-per-TS 31 csuLoopAndBert 32 dsuLoopAndBert 33 remoteOcuLoopAndBert 34 remoteCsuLoopAndBert 35 remoteDsuLoopAndBert 36 e.g : If the return value is 00000003 hex -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
INT prtSRdnStatus1.3.6.1.4.1.164.3.1.4.1.1.1.17INTEGERread-onlyRedundancy Status of this port. noRdn - this port is not part of a Redundancy pair/group. offline - this port is offline from Redundancy point of view. online - this port is online from Redundancy point of view.
prtSAlrTable1.3.6.1.4.1.164.3.1.4.1.2not-accessibleThe list of port agent alarms.
prtSAlrEntry1.3.6.1.4.1.164.3.1.4.1.2.1not-accessibleAn entry in table.
I32 prtSAlrIdx1.3.6.1.4.1.164.3.1.4.1.2.1.1Integer32read-onlyA unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive
INT prtSAlrSltIdx1.3.6.1.4.1.164.3.1.4.1.2.1.2INTEGERread-onlyThis attribute indicates a unique identifier of the slot where the card is inserted. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16) are not valid. For the Vmux2100 Main Board clA (3) is used.
I32 prtSAlrPrtIdx1.3.6.1.4.1.164.3.1.4.1.2.1.3Integer32read-onlyThis attribute indicates a unique identifier of the port the alarm applies to. All the values are valid. No alarms exist for a port which does not exist. Valid valuesfor MP-2100/2200: exPrt1 (1) .. exPrt16 (16) , inPrt1 (101) .. inPrt48 (148), IP Bundles. For other products, see product's spec.
STR prtSAlrCodeDescription1.3.6.1.4.1.164.3.1.4.1.2.1.4DisplayStringread-onlyThis attribute is a full text description of the alarm. The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter.
I32 prtSAlrCode1.3.6.1.4.1.164.3.1.4.1.2.1.5Integer32read-onlyA code identifying the alarm of an entry in the alarm status table at port level.
INT prtSAlrSeverity1.3.6.1.4.1.164.3.1.4.1.2.1.6INTEGERread-onlyThe severity of the alarm.
INT prtSAlrState1.3.6.1.4.1.164.3.1.4.1.2.1.7INTEGERread-onlyState of the alarm.
I32 prtSAlrCounter1.3.6.1.4.1.164.3.1.4.1.2.1.8Integer32read-onlyA counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately.
INT prtSAlrMask1.3.6.1.4.1.164.3.1.4.1.2.1.9INTEGERread-onlyAlarm mask : on/off.
INT prtSAlrInvert1.3.6.1.4.1.164.3.1.4.1.2.1.10INTEGERread-onlyAlarm invert : on/off.
INT prtSAlrCardType1.3.6.1.4.1.164.3.1.4.1.2.1.11INTEGERread-onlyThis attribute indicates the type of card installed in the specific slot position. The enumeration is according to mdlSInstCardType.
statisPrtGen1.3.6.1.4.1.164.3.1.4.1.3
prtFrStatis1.3.6.1.4.1.164.3.1.4.1.3.1
prtFrStatisTable1.3.6.1.4.1.164.3.1.4.1.3.1.1not-accessibleThis table is applicable only for an active port running an FR protocol .
prtFrStatisEntry1.3.6.1.4.1.164.3.1.4.1.3.1.1.1not-accessibleAn entry in table.
INT prtFrStatisSltIdx1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.1INTEGERread-onlyThis attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255).
INT prtFrStatisPrtIdx1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.2INTEGERread-onlyThis attribute indicates a unique port number.
INT prtFrStatisInvIdx1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.3INTEGERread-onlyThe Interval of 15 min. for which the following statistics counters are applicable.
I32 prtFrTimeElapsed1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.4Integer32read-onlyThe number of seconds that have elapsed since the beginning of the current error-measurement interval. This object is applicable mainly for the current interval. For other interval: - if data is available: value will be 899. - if data is not available: value will be 0.
C32 prtFrRxTotalFrames1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.5Counter32read-onlyThe total number of frames received by this port during the selected interval.
C32 prtFrTxTotalFrames1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.6Counter32read-onlyThe total number of frames sent by this port during the selected interval.
C32 prtFrRxTotalBytes1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.7Counter32read-onlyThe total number of bytes received by this port during the selected interval.
C32 prtFrTxTotalBytes1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.8Counter32read-onlyThe total number of bytes sent by this port during the selected interval.
C32 prtFrRxMngFrames1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.9Counter32read-onlyThe management number of frames received by this port during the selected interval.
C32 prtFrTxMngFrames1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.10Counter32read-onlyThe management number of frames sent by this port during the selected interval.
C32 prtFrRxDeFrames1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.11Counter32read-onlyThe number of De frames received by this port during the selected interval.
C32 prtFrTxDeFrames1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.12Counter32read-onlyThe number of De frames sent by this port during the selected interval.
C32 prtFrRxDcrdCongDeFr1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.13Counter32read-onlyThe number of De frames discarded due to congestion, received by this port during the selected interval.
C32 prtFrTxDcrdCongDeFr1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.14Counter32read-onlyThe number of De frames discarded due to congestion, sent by this port during the selected interval.
C32 prtFrRxDcrdCongAllFr1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.15Counter32read-onlyAll the frames discarded due to congestion, received by this port during the selected interval.
C32 prtFrTxDcrdCongAllFr1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.16Counter32read-onlyAll the frames discarded due to congestion, sent by this port during the selected interval.
C32 prtFrRxFecn1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.17Counter32read-onlyNumber of frames received by this port during the selected interval, indicating forward congestion.
C32 prtFrTxFecn1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.18Counter32read-onlyNumber of frames sent by this port during the selected interval, indicating forward congestion.
C32 prtFrRxBecn1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.19Counter32read-onlyNumber of frames received by this port during the selected interval, indicating backward congestion.
C32 prtFrTxBecn1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.20Counter32read-onlyNumber of frames sent by this port during the selected interval, indicating backward congestion.
C32 prtFrRxBeViol1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.21Counter32read-onlyNumber of data frames received by this port during the selected interval, exceeding the Burst Excess value.
C32 prtFrTxBeViol1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.22Counter32read-onlyNumber of data frames sent by this port during the selected interval, exceeding the Burst Excess value.
C32 prtFrRxBcViol1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.23Counter32read-onlyNumber of data frames received by this port during the selected interval, exceeding the Burst Committed value.
C32 prtFrTxBcViol1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.24Counter32read-onlyNumber of data frames sent by this port during the selected interval, exceeding the Burst Committed value.
prtCrStatis1.3.6.1.4.1.164.3.1.4.1.3.2
prtCrStatisTable1.3.6.1.4.1.164.3.1.4.1.3.2.1not-accessibleThis table is applicable only for an active port running a CR protocol .
prtCrStatisEntry1.3.6.1.4.1.164.3.1.4.1.3.2.1.1not-accessibleAn entry in table.
INT prtCrStatisSltIdx1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.1INTEGERread-onlyThis attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255).
INT prtCrStatisPrtIdx1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.2INTEGERread-onlyThis attribute indicates a unique port number.
INT prtCrStatisInvIdx1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.3INTEGERread-onlyThe Interval of 15 min. for which the following statistics counters are applicable.
I32 prtCrTimeElapsed1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.4Integer32read-onlyThe number of seconds that have elapsed since the beginning of the current error-measurement interval. This object is applicable mainly for the current interval. For other interval: - if data is available: value will be 899. - if data is not available: value will be 0.
C32 prtCrRxTotalCells1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.5Counter32read-onlyThe total number of cells received by this port during the selected interval.
C32 prtCrTxTotalCells1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.6Counter32read-onlyThe total number of cells sent by this port during the selected interval.
C32 prtCrRxDataCells1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.7Counter32read-onlyThe number of Data Cells received by this port during the selected interval.
C32 prtCrTxDataCells1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.8Counter32read-onlyThe number of Data Cells sent by this port during the selected interval.
prtDlciStatis1.3.6.1.4.1.164.3.1.4.1.3.3
prtDlciStatisTable1.3.6.1.4.1.164.3.1.4.1.3.3.1not-accessibleThis table is applicable only for an active port running an FR, FR+ or CR protocol, with valid DLCIs .
prtDlciStatisEntry1.3.6.1.4.1.164.3.1.4.1.3.3.1.1not-accessibleAn entry in table.
INT prtDlciSltIdx1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.1INTEGERread-onlyThis attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255).
INT prtDlciPrtIdx1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.2INTEGERread-onlyThis attribute indicates a unique port number.
I32 prtDlciIdx1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.3Integer32read-onlyThis attribute indicates a unique DLCI index for each valid DLCI (16..991).
C32 prtDlciRxDeFrames1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.4Counter32read-onlyThe number of De frames received by this DLCI.
C32 prtDlciTxDeFrames1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.5Counter32read-onlyThe number of De frames sent by this DLCI.
C32 prtDlciRxDcrdCongDeFr1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.6Counter32read-onlyThe number of De frames discarded due to congestion, received by this DLCI.
C32 prtDlciTxDcrdCongDeFr1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.7Counter32read-onlyThe number of De frames discarded due to congestion, sent by this DLCI.
C32 prtDlciRxDcrdCongAllFr1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.8Counter32read-onlyAll the frames discarded due to congestion, received by this DLCI.
C32 prtDlciTxDcrdCongAllFr1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.9Counter32read-onlyAll the frames discarded due to congestion, sent by this DLCI.
C32 prtDlciTxFecn1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.10Counter32read-onlyNumber of frames sent by this DLCI, indicating forward congestion.
C32 prtDlciTxBecn1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.11Counter32read-onlyNumber of frames sent by this DLCI, indicating backward congestion.
C32 prtDlciRxBeViol1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.12Counter32read-onlyNumber of data frames received by this DLCI, exceeding the Burst Excess value.
C32 prtDlciTxBeViol1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.13Counter32read-onlyNumber of data frames sent by this DLCI, exceeding the Burst Excess value.
C32 prtDlciRxBcViol1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.14Counter32read-onlyNumber of data frames received by this DLCI, exceeding the Burst Committed value.
C32 prtDlciTxBcViol1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.15Counter32read-onlyNumber of data frames sent by this DLCI, exceeding the Burst Committed value.
prtT1Statis1.3.6.1.4.1.164.3.1.4.1.3.4
prtT1FdlMsgTable1.3.6.1.4.1.164.3.1.4.1.3.4.1not-accessibleThis table is applicable for a T1 interface with 'esf' LineType .
prtT1FdlMsgEntry1.3.6.1.4.1.164.3.1.4.1.3.4.1.1not-accessibleAn entry in table.
INT prtT1FdlMsgSltIdx1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.1INTEGERread-onlyThis attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
INT prtT1FdlMsgPrtIdx1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.2INTEGERread-onlyThis attribute indicates a unique port number. MTML-1/T1 modules have just one external interface.
INT prtT1FdlMsgFdlTxRx1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.3INTEGERread-onlyThe Fdl tx/rx reference of the Fdl message.
OCT prtT1FdlMsg1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.4OCTET STRINGread-onlyFDL message.
cnfgPrtGen1.3.6.1.4.1.164.3.1.4.2
prtExTsSplitTable1.3.6.1.4.1.164.3.1.4.2.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry, except prtExTsBitTest that will be written directly to the Active Configuration.
prtExTsSplitEntry1.3.6.1.4.1.164.3.1.4.2.1.1not-accessibleAn entry in table.
I32 prtExTsCnfgIdx1.3.6.1.4.1.164.3.1.4.2.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtExTsSltIdx1.3.6.1.4.1.164.3.1.4.2.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - for stand-alone units.
I32 prtExTsPrtIdx1.3.6.1.4.1.164.3.1.4.2.1.1.3Integer32read-onlyThis attribute indicates a unique port number. Most ML cards have only one external interface. inPrt1 - for MTML-H/E1 cards. For other products' index see their specification.
I32 prtExTsIdx1.3.6.1.4.1.164.3.1.4.2.1.1.4Integer32read-onlyThis attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines, time slot 16 is not valid for data, it is dedicated to multiframe synchronization bits and voice signaling.
I32 prtExTsBit1.3.6.1.4.1.164.3.1.4.2.1.1.5Integer32read-onlyThis attribute indicates a unique Bit within the time slot. The valid Bits are: 1..8. 255=NA.
INT prtExTsIConSlot1.3.6.1.4.1.164.3.1.4.2.1.1.6INTEGERread-writeThis attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - for stand-alone units.
I32 prtExTsIConPrt1.3.6.1.4.1.164.3.1.4.2.1.1.7Integer32read-writeThis attribute indicates the internally (In Mux) connected/routed port. For other products' index see their specification.
INT prtExTsBitTest1.3.6.1.4.1.164.3.1.4.2.1.1.8INTEGERread-writeThis attribute indicates a test to be activated on the selected Bit. It is applicable only when prtExPh1MlTsTest=split(254). none - no test is applied for the selected Bit. notApplicable - when prtExPh1MlTsTest is NOT split(254).
OCT prtExTsTxSignaling1.3.6.1.4.1.164.3.1.4.2.1.1.9OCTET STRINGread-onlyLink - Tx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is sent to Link for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
OCT prtExTsRxSignaling1.3.6.1.4.1.164.3.1.4.2.1.1.10OCTET STRINGread-onlyLink - Rx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is received from Link for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
OCT prtExTsTxIoSignaling1.3.6.1.4.1.164.3.1.4.2.1.1.11OCTET STRINGread-onlyIO - Tx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is sent to IO port for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
OCT prtExTsRxIoSignaling1.3.6.1.4.1.164.3.1.4.2.1.1.12OCTET STRINGread-onlyIO - Rx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is received from IO port for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
prtCnfgAgenda1.3.6.1.4.1.164.3.1.4.2.2
prtAgendaBehaviourTable1.3.6.1.4.1.164.3.1.4.2.2.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtAgendaBehaviourEntry1.3.6.1.4.1.164.3.1.4.2.2.1.1not-accessibleAn entry in table.
I32 prtAgendaBehaviourCnfgIdx1.3.6.1.4.1.164.3.1.4.2.2.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
I32 prtAgendaBehaviourSltIdx1.3.6.1.4.1.164.3.1.4.2.2.1.1.2Integer32read-onlyThis parameter should be: - slot number for MX3000 - 255 = N/A for MX300/30.
I32 prtAgendaBehaviourPrtIdx1.3.6.1.4.1.164.3.1.4.2.2.1.1.3Integer32read-onlyThis parameter should be: - port number for MX300/30 - 100 = N/A for MX3000.
INT prtAgendaBehaviourOnOff1.3.6.1.4.1.164.3.1.4.2.2.1.1.4INTEGERread-writeSetting this command to on(3) enables the agenda function at module (3000) or port (300/30) level.
prtCnfgAgendaTable1.3.6.1.4.1.164.3.1.4.2.2.2not-accessibleThis table allows the user to schedule the time a session is active per week basis.
prtCnfgAgendaEntry1.3.6.1.4.1.164.3.1.4.2.2.2.1not-accessibleAn entry in table.
I32 prtCnfgAgendaCnfgIdx1.3.6.1.4.1.164.3.1.4.2.2.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
I32 prtCnfgAgendaSltIdx1.3.6.1.4.1.164.3.1.4.2.2.2.1.2Integer32read-onlyThis attribute is equal to: -slot number for MX3000 -255 = N/A for MX300/30
I32 prtCnfgAgendaPrtIdx1.3.6.1.4.1.164.3.1.4.2.2.2.1.3Integer32read-onlyThis attribute is equal to: - port number for MX300/30 - port number for MX3000. For example 1-4 in MHS-4 cards. - 100 = N/A for MX3000 when not used.
INT prtCnfgAgendaDayIdx1.3.6.1.4.1.164.3.1.4.2.2.2.1.4INTEGERread-onlyThis attribute for which day of the week this row applies.
I32 prtCnfgAgendaSesId1.3.6.1.4.1.164.3.1.4.2.2.2.1.5Integer32read-onlyThe user may define 4 different active intervals per day.
I32 prtCnfgAgendaFrom1.3.6.1.4.1.164.3.1.4.2.2.2.1.6Integer32read-writeStart from time interval in seconds.
I32 prtCnfgAgendaTo1.3.6.1.4.1.164.3.1.4.2.2.2.1.7Integer32read-writeTo time interval in seconds.
prtGenCnfgTable1.3.6.1.4.1.164.3.1.4.2.3not-accessibleThis table allows the user to configure general port parameters.
prtGenCnfgEntry1.3.6.1.4.1.164.3.1.4.2.3.1not-accessibleAn entry in table.
I32 prtGenCnfgIdx1.3.6.1.4.1.164.3.1.4.2.3.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
INT prtGenCnfgSltIdx1.3.6.1.4.1.164.3.1.4.2.3.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted.
I32 prtGenCnfgPrtIdx1.3.6.1.4.1.164.3.1.4.2.3.1.3Integer32read-onlyThis attribute indicates a unique external or internal port number. For MP: exPrt1 (1) .. exPrt16 (16) , notApplicable(100), inPrt1 (101) .. inPrt84 (184)
INT prtGenCnfgLinkToSlot1.3.6.1.4.1.164.3.1.4.2.3.1.4INTEGERread-writeThis attribute indicates the slot of the ML card to which the IO port is mapped.
I32 prtGenCnfgLinkToPort1.3.6.1.4.1.164.3.1.4.2.3.1.5Integer32read-writeThis attribute indicates the port in the prtGenCnfgLinkToSlot of the ML card to which the IO port is mapped. For MP: exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109), inPrt10 (110), inPrt11 (111), inPrt12 (112), inPrt13 (113), inPrt14 (114), inPrt15 (115), inPrt16 (116), inPrt17 (117), inPrt18 (118), inPrt19 (119), inPrt20 (120), inPrt21 (121), inPrt22 (122), inPrt23 (123), inPrt24 (124), inPrt25 (125), inPrt26 (126), inPrt27 (127), inPrt28 (128), inPrt29 (129), inPrt30 (130), inPrt31 (131), inPrt32 (132), inPrt33 (133), inPrt34 (134), inPrt35 (135), inPrt36 (136), inPrt37 (137), inPrt38 (138), inPrt39 (139), inPrt40 (140), inPrt41 (141), inPrt42 (142), inPrt43 (143), inPrt44 (144), inPrt45 (145), inPrt46 (146), inPrt47 (147), inPrt48 (148), inPrt49 (149), inPrt50 (150), inPrt51 (151), inPrt52 (152), inPrt53 (153), inPrt54 (154), inPrt55 (155), inPrt56 (156), inPrt57 (157), inPrt58 (158), inPrt59 (159), inPrt60 (160), inPrt61 (161), inPrt62 (162), inPrt63 (163), inPrt64 (164), inPrt65 (165), inPrt66 (166), inPrt67 (167), inPrt68 (168), inPrt69 (169), inPrt70 (170), inPrt71 (171), inPrt72 (172), inPrt73 (173), inPrt74 (174), inPrt75 (175), inPrt76 (176), inPrt77 (177), inPrt78 (178), inPrt79 (179), inPrt80 (180), inPrt81 (181), inPrt82 (182), inPrt83 (183), inPrt84 (184), notApplicable (255)
I32 prtGenCnfgPortId1.3.6.1.4.1.164.3.1.4.2.3.1.6Integer32read-writeIO Port Id for V5.1 use. This object is applicable only for part of the PSTN and ISDN IO ports. Generally, 0 is a valid value. Nevertheless, for ports that do not support this object, the value will be: notApplicable= 0
INT prtGenCnfgBusConnection1.3.6.1.4.1.164.3.1.4.2.3.1.7INTEGERread-writeThis object indicates the support of the card regarding Bus Connection. Same value for all ports of the card. partial = 2 Buses (AB) full = 4 Buses (ABCD) partial CD = 2 Buses CD Actually the support depends on the card's HW. But, since CL has to assign data on Buses even when the card is not installed, this object has to be configured. If the actual card installed will not match the value configured, an Alarm will be issued.
INT prtGenCnfgInbandMng1.3.6.1.4.1.164.3.1.4.2.3.1.8INTEGERread-writeThis object indicates whether Inband Management is used over the link.
INT prtGenCnfgInbandMngRoutProt1.3.6.1.4.1.164.3.1.4.2.3.1.9INTEGERread-writeThis object indicates the Inband Mng Routing Protocol of the port.
INT prtGenCnfgProtectionMode1.3.6.1.4.1.164.3.1.4.2.3.1.10INTEGERread-writeThis object indicates the Protection Mode of the port. notApplicable- when Bus Protection Point=No. For VC-4/Omni card this object is supported RO.
INT prtGenCnfgConnect1.3.6.1.4.1.164.3.1.4.2.3.1.11INTEGERread-writeThis object indicates whether the port should be considered in any of the mux algorithms.
INT prtGenCnfgSignalingType1.3.6.1.4.1.164.3.1.4.2.3.1.12INTEGERread-writeThis object selects the Type of Signaling used by the port.
cmprPrtGen1.3.6.1.4.1.164.3.1.4.3
prtCmprTable1.3.6.1.4.1.164.3.1.4.3.1not-accessibleA table.
prtCmprEntry1.3.6.1.4.1.164.3.1.4.3.1.1not-accessibleAn entry in table.
I32 prtCmprTypIdx1.3.6.1.4.1.164.3.1.4.3.1.1.1Integer32read-onlyThis attribute indicates the Type of the Compressed being referred.
I32 prtCmprCnfgIdx1.3.6.1.4.1.164.3.1.4.3.1.1.2Integer32read-onlyThis attribute indicates the configuration to which the Compressed information is related.
I32 prtCmprVersion1.3.6.1.4.1.164.3.1.4.3.1.1.3Integer32read-onlyThis attribute indicates the version of the internal format of the Compressed data
INT prtCmprSltIdx1.3.6.1.4.1.164.3.1.4.3.1.1.4INTEGERread-onlyThis attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
I32 prtCmprPrtIdx1.3.6.1.4.1.164.3.1.4.3.1.1.5Integer32read-onlyThis attribute indicates a unique identifier of the port the compressed information relates to. Valid values: exPrt1 (1) .. exPrt16 (16) , inPrt1 (101) .. inPrt48 (148).
OCT prtCmprObj1.3.6.1.4.1.164.3.1.4.3.1.1.6OCTET STRINGread-writeThis attribute is the compressed information itself.
OCT prtCmprStatisticObj1.3.6.1.4.1.164.3.1.4.3.1.1.7OCTET STRINGread-onlyThis attribute is the compressed statistics information itself.
prtDlciCmprTable1.3.6.1.4.1.164.3.1.4.3.2not-accessibleA table.
prtDlciCmprEntry1.3.6.1.4.1.164.3.1.4.3.2.1not-accessibleAn entry in table.
I32 prtDlciCmprCnfgIdx1.3.6.1.4.1.164.3.1.4.3.2.1.1Integer32read-onlyThis attribute indicates the configuration to which the Compressed information is related.
I32 prtDlciCmprVersion1.3.6.1.4.1.164.3.1.4.3.2.1.2Integer32read-onlyThis attribute indicates the version of the internal format of the Compressed data
INT prtDlciCmprSltIdx1.3.6.1.4.1.164.3.1.4.3.2.1.3INTEGERread-onlyThis attribute indicates a unique number of the slot position where the module is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
INT prtDlciCmprPrtIdx1.3.6.1.4.1.164.3.1.4.3.2.1.4INTEGERread-onlyThis attribute indicates a unique identifier of the port the compressed information relates to. All the values are valid.
I32 prtDlciCmprDlciIdx1.3.6.1.4.1.164.3.1.4.3.2.1.5Integer32read-onlyThis attribute indicates a unique identifier of the Dlci the compressed information relates to. The values are between 16 - 991.
OCT prtDlciCmprObj1.3.6.1.4.1.164.3.1.4.3.2.1.6OCTET STRINGread-writeThis attribute is the compressed information itself.
prtAlarmsCmprTable1.3.6.1.4.1.164.3.1.4.3.3not-accessibleA table.
prtAlarmsCmprEntry1.3.6.1.4.1.164.3.1.4.3.3.1not-accessibleAn entry in table.
I32 prtAlarmsCmprVersion1.3.6.1.4.1.164.3.1.4.3.3.1.1Integer32read-onlyThis attribute indicates the version of the internal format of the Compressed data
I32 prtAlarmsCmprAlarmSlot1.3.6.1.4.1.164.3.1.4.3.3.1.2Integer32read-onlyThis attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid. For Stand-alone units, notApplicable(255) will appear.
I32 prtAlarmsCmprAlarmPort1.3.6.1.4.1.164.3.1.4.3.3.1.3Integer32read-onlyThis attribute indicates a unique identifier of the port the alarm applies to. All the values are valid. No alarms exist for a non-existing port. IP Bundles are considered a port too, for this matter.
I32 prtAlarmsCmprAlarmIdx1.3.6.1.4.1.164.3.1.4.3.3.1.4Integer32read-onlyA unique number to identify an entry in the alarm status table of the agent.
OCT prtAlarmsCmprObj1.3.6.1.4.1.164.3.1.4.3.3.1.5OCTET STRINGread-onlyThis attribute is the compressed information itself.
mapWanGen1.3.6.1.4.1.164.3.1.5
agnLinkMapTable1.3.6.1.4.1.164.3.1.5.1not-accessibleA table.
agnLinkMapEntry1.3.6.1.4.1.164.3.1.5.1.1not-accessibleAn entry in table.
I32 mapLinkId1.3.6.1.4.1.164.3.1.5.1.1.1Integer32read-onlyA unique identifier of the link
INT mapLinkSltIdx1.3.6.1.4.1.164.3.1.5.1.1.2INTEGERread-writeThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries clA(3), io6(10)..io12(16) are not valid.
INT mapLinkPrtIdx1.3.6.1.4.1.164.3.1.5.1.1.3INTEGERread-writeThis attribute indicates a unique port number.
INT mapLinkStatus1.3.6.1.4.1.164.3.1.5.1.1.4INTEGERread-onlyThis attribute indicates the status of the link between the two muxes
diverseIfWanGen1.3.6.1.4.1.164.3.1.6
ethIf1.3.6.1.4.1.164.3.1.6.1
ethIfTable1.3.6.1.4.1.164.3.1.6.1.1not-accessibleA table.
ethIfEntry1.3.6.1.4.1.164.3.1.6.1.1.1not-accessibleAn entry in table.
I32 ethIfIdx1.3.6.1.4.1.164.3.1.6.1.1.1.1Integer32read-onlyA unique index of the ethernet interface/port.
INT ethMode1.3.6.1.4.1.164.3.1.6.1.1.1.2INTEGERread-writeThis object indicates the Ethernet mode of operation.
INT ethBridgingMode1.3.6.1.4.1.164.3.1.6.1.1.1.3INTEGERread-writeThis object indicates the bridging mode of the Ethernet interface.
INT ethEncapsulationCRCMode1.3.6.1.4.1.164.3.1.6.1.1.1.4INTEGERread-writeThis object define the encapsulation type requested for the Ethernet interface. It indicates if we transfer the Ethernet frame to the other side with or without the CRC.
INT ethBackPressure1.3.6.1.4.1.164.3.1.6.1.1.1.5INTEGERread-writeThis parameter defines whether to enable or disable Back pressure. Back Pressure is a flow control parameter.
INT ethLimit41.3.6.1.4.1.164.3.1.6.1.1.1.6INTEGERread-writeThis parameter determine the Back off algorithm mode. Every 4 following collisions the Framer will be thrown out (4 times more than usuall).
INT ethSkipInitReset1.3.6.1.4.1.164.3.1.6.1.1.1.7INTEGERread-writeThis parameter defines whether read status on reset.
INT ethMulticastBlock1.3.6.1.4.1.164.3.1.6.1.1.1.8INTEGERread-writeThis parameter defines whether to send multicast message to WAN from LAN or not.
INT ethBroadcastBlock1.3.6.1.4.1.164.3.1.6.1.1.1.9INTEGERread-writeThis parameter defines whether to send broadcast message to WAN from LAN or not.
INT ethSpeed1.3.6.1.4.1.164.3.1.6.1.1.1.10INTEGERread-writeThis parameter defines the line speed.
INT ethRip21.3.6.1.4.1.164.3.1.6.1.1.1.11INTEGERread-writeThis parameter defines whether to send RIP II message to WAN from LAN or not
INT ethPortPriority1.3.6.1.4.1.164.3.1.6.1.1.1.12INTEGERread-writeThis parameter defines if priority is to be considered for this Port.
INT ethPortMngEnable1.3.6.1.4.1.164.3.1.6.1.1.1.13INTEGERread-writeThis parameter defines whether management data can pass through this Port. localOnly (4) - Only local device can be managed via this port.
MAC ethFlowCtrlMacAddress1.3.6.1.4.1.164.3.1.6.1.1.1.14MacAddressread-writeIn case of flow control - transmit frame with this specific MAC address to inform the other end to stop sending frames. Default: 01.80.C2.00.00.01.
I32 ethRateLimit1.3.6.1.4.1.164.3.1.6.1.1.1.15Integer32read-writeThis parameter defines the Rate Limit of the line, in Mbps.
INT ethJumboFrameEnable1.3.6.1.4.1.164.3.1.6.1.1.1.16INTEGERread-writeThis parameter defines whether to support Jumbo Frame or not.
INT ethAutoMdiXEnable1.3.6.1.4.1.164.3.1.6.1.1.1.17INTEGERread-writeThis parameter defines whether to support automatic change between MDI and MDI[X].
INT ethPortDataEnable1.3.6.1.4.1.164.3.1.6.1.1.1.18INTEGERread-writeThis parameter defines whether this port is enabled for data (that is not management). no(2) - management can run on this port yes(3) - both management and payload data can run on this port.
I32 ethIfUse1.3.6.1.4.1.164.3.1.6.1.1.1.19Integer32read-writeThis parameter defines the use of the port. 1=NET 2=USER .
INT ethLineOam1.3.6.1.4.1.164.3.1.6.1.1.1.20INTEGERread-writeThis parameter defines the working mode of 802.AH OAM mechanism.
INT ethRoutingProtocol1.3.6.1.4.1.164.3.1.6.1.1.1.21INTEGERread-writeThis parameter defines the routing protocol used above ETH port.
INT ethMdiXManualSwitch1.3.6.1.4.1.164.3.1.6.1.1.1.22INTEGERread-writeThis parameter sets the port to be MDI-X (cross-over) or MDI (straight-through). It is applicable only when ethAutoMdiXEnable = no, namely, only when the automatic MDI/MDIX crossover function is disabled.
INT ethDot1xEnable1.3.6.1.4.1.164.3.1.6.1.1.1.23INTEGERread-writeDetermines if the Port-Based Network Access Protocol (IEEE-802.1x) is enabled for the Ethernet Port.
INT ethPartnerRateMode1.3.6.1.4.1.164.3.1.6.1.1.1.24INTEGERread-writeFor converters having couples of ports, where each couple contains a port with an SFP connector and a port with a RJ connector, this parameter is relevant for the SFP port. It affects Rate configuration of its partner (RJ port). manual - user can configure manually ETH parameters of RJ port (e.g Autonegotiation, Max Capability Advertised, etc...) automatic - SFP Rate will be enforced on the RJ port. In this mode, user cannot configure the Rate related parameters of the RJ port (e.g Autonegotiation, Max Capability Advertised, etc...)
INT ethDot1xPortRole1.3.6.1.4.1.164.3.1.6.1.1.1.25INTEGERread-writeDetermine the functionality of the port in the Port-Based Network Access Protocol (IEEE-802.1x) - either Authenticator or Supplicant.
ethIfPerformance1.3.6.1.4.1.164.3.1.6.1.2
ethIfCurrentTable1.3.6.1.4.1.164.3.1.6.1.2.1not-accessibleThe Ethernet Current table. When the index specifies the Ethernet interface (only), the counters are for an interval of 15 minutes.
ethIfCurrentEntry1.3.6.1.4.1.164.3.1.6.1.2.1.1not-accessibleAn entry in the Ethernet Current table.
I32 ethIfCurrentIndex1.3.6.1.4.1.164.3.1.6.1.2.1.1.1Integer32read-onlyThe index of the Ethernet interface. It may be ifIndex. For some devices (e.g RICi-622GE), supporting several types of intervals, this index will be a concatenation of the port index and interval type. Interval type can indicate: 1 minute, 15 minutes, 1 hour, 24 hours. For the exact formula, see device specification.
OCT ethIfCurrentStatus1.3.6.1.4.1.164.3.1.6.1.2.1.1.2OCTET STRINGread-onlyThe status of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
G32 ethIfCurrentInFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.3Gauge32read-onlyThe counter associated with the number of received frames, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentInOctets1.3.6.1.4.1.164.3.1.6.1.2.1.1.4Gauge32read-onlyThe counter associated with the number of received octets, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentAlignmentErrors1.3.6.1.4.1.164.3.1.6.1.2.1.1.5Gauge32read-onlyThe counter associated with the number of received frames, which are not complete (The result of dividing the number of bits by 8 is not an Integer), encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentFCSErrors1.3.6.1.4.1.164.3.1.6.1.2.1.1.6Gauge32read-onlyThe counter associated with the number of received frames that didn't pass the FCS test, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentLengthError1.3.6.1.4.1.164.3.1.6.1.2.1.1.7Gauge32read-onlyThe counter associated with the number of received frames with length error, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentOutFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.8Gauge32read-onlyThe counter associated with the number of transmitted frames, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentOutOctets1.3.6.1.4.1.164.3.1.6.1.2.1.1.9Gauge32read-onlyThe counter associated with the number of transmitted octets, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentSingleCollisionFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.10Gauge32read-onlyThe counter associated with the number of successfully transmitted frames for which transmission was inhibited by exactly one collision, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentMultipleCollisionFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.11Gauge32read-onlyThe counter associated with the number of successfully transmitted frames for which transmission was inhibited by more than one collision, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentDeferredTransmissions1.3.6.1.4.1.164.3.1.6.1.2.1.1.12Gauge32read-onlyThe counter associated with the number of transmitted frames for which the first transmission attempt was delayed due to a busy media, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentLateCollisions1.3.6.1.4.1.164.3.1.6.1.2.1.1.13Gauge32read-onlyThe counter associated with the number of times that a collision was detected later than the first 64 bytes of the frame, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentCarrierSenseErrors1.3.6.1.4.1.164.3.1.6.1.2.1.1.14Gauge32read-onlyThe counter associated with the number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentInputCongestionDropped1.3.6.1.4.1.164.3.1.6.1.2.1.1.15Gauge32read-onlyThe counter associated with the number of frames dropped due to lack of buffers in ingress pool, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentOutputCongestionDropped1.3.6.1.4.1.164.3.1.6.1.2.1.1.16Gauge32read-onlyThe counter associated with the number of dropped frames due to a congestion, encountered by the Transmit direction to the Ethernet interface in the current interval.
G32 ethIfCurrentOverflowInFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.17Gauge32read-onlyThe number of times the associated ethIfCurrentInFrames counter has overflowed in the current interval.
G32 ethIfCurrentOverflowInOctets1.3.6.1.4.1.164.3.1.6.1.2.1.1.18Gauge32read-onlyThe number of times the associated ethIfCurrentInOctets counter has overflowed in the current interval.
G32 ethIfCurrentOverflowFCSErrors1.3.6.1.4.1.164.3.1.6.1.2.1.1.19Gauge32read-onlyThe number of times the associated ethIfCurrentFCSErrors counter has overflowed in the current interval.
G32 ethIfCurrentOverflowOutFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.20Gauge32read-onlyThe number of times the associated ethIfCurrentOutFrames counter has overflowed in the current interval.
G32 ethIfCurrentOverflowOutOctets1.3.6.1.4.1.164.3.1.6.1.2.1.1.21Gauge32read-onlyThe number of times the associated ethIfCurrentOutOctets counter has overflowed in the current interval.
G32 ethIfCurrentOverflowMultipleCollisionFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.22Gauge32read-onlyThe number of times the associated ethIfCurrentMultipleCollisionFrames counter has overflowed in the current interval.
G32 ethIfCurrentInUnicastFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.23Gauge32read-onlyThe number of received Unicast frames, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentOutUnicastFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.24Gauge32read-onlyThe number of transmitted Unicast frames, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentInMulticastFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.25Gauge32read-onlyThe number of received Multicast frames, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentOutMulticastFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.26Gauge32read-onlyThe number of transmitted Multicast frames, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentInBroadcastFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.27Gauge32read-onlyThe number of received Broadcast frames, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentOutBroadcastFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.28Gauge32read-onlyThe number of transmitted Broadcast frames, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentInDiscardFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.29Gauge32read-onlyThe number of received Discarded frames, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentOutDiscardFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.30Gauge32read-onlyThe number of transmitted Discarded frames, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentInPauseFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.31Gauge32read-onlyThe number of received Pause frames, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentOutPauseFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.32Gauge32read-onlyThe number of transmitted Pause frames, encountered by the Ethernet interface in the current interval.
G32 ethIfCurrentOverflowInUnicastFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.33Gauge32read-onlyThe number of times the associated ethIfCurrentInUnicastFrames counter has overflowed in the current interval.
G32 ethIfCurrentOverflowOutUnicastFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.34Gauge32read-onlyThe number of times the associated ethIfCurrentOutUnicastFrames counter has overflowed in the current interval.
G32 ethIfCurrentOverflowInMulticastFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.35Gauge32read-onlyThe number of times the associated ethIfCurrentInMulticastFrames counter has overflowed in the current interval.
G32 ethIfCurrentOverflowOutMulticastFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.36Gauge32read-onlyThe number of times the associated ethIfCurrentOutMulticastFrames counter has overflowed in the current interval.
G32 ethIfCurrentOverflowInBroadcastFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.37Gauge32read-onlyThe number of times the associated ethIfCurrentInBroadcastFrames counter has overflowed in the current interval.
G32 ethIfCurrentOverflowOutBroadcastFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.38Gauge32read-onlyThe number of times the associated ethIfCurrentOutBroadcastFrames counter has overflowed in the current interval.
G32 ethIfCurrentOverflowInDiscardFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.39Gauge32read-onlyThe number of times the associated ethIfCurrentInDiscardFrames counter has overflowed in the current interval.
G32 ethIfCurrentOverflowOutDiscardFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.40Gauge32read-onlyThe number of times the associated ethIfCurrentOutDiscardFrames counter has overflowed in the current interval.
G32 ethIfCurrentOverflowInPauseFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.41Gauge32read-onlyThe number of times the associated ethIfCurrentInPauseFrames counter has overflowed in the current interval.
G32 ethIfCurrentOverflowOutPauseFrames1.3.6.1.4.1.164.3.1.6.1.2.1.1.42Gauge32read-onlyThe number of times the associated ethIfCurrentOutPauseFrames counter has overflowed in the current interval.
ethIfIntervalTable1.3.6.1.4.1.164.3.1.6.1.2.2not-accessibleThe Ethernet Interval table. When ethIfIntervalIndex specifies the Ethernet interface (only), the counters are for an interval of 15 minutes.
ethIfIntervalEntry1.3.6.1.4.1.164.3.1.6.1.2.2.1not-accessibleAn entry in the Ethernet Interval table.
I32 ethIfIntervalIndex1.3.6.1.4.1.164.3.1.6.1.2.2.1.1Integer32read-onlyThe index of the Ethernet interface. It may be ifIndex. For some devices (e.g RICi-622GE), supporting several types of intervals, this index will be a concatenation of the port index and interval type. Interval type can indicate: 1 minute, 15 minutes, 1 hour, 24 hours. For the exact formula, see device specification.
I32 ethIfIntervalNumber1.3.6.1.4.1.164.3.1.6.1.2.2.1.2Integer32read-onlyThe Interval Number. This number is between 1 and x, where 1 is the most recently completed interval and x is the least recently completed interval. For 15 minute intervals, usually x=96, but it can be different, depending on device capabilities.
OCT ethIfIntervalStatus1.3.6.1.4.1.164.3.1.6.1.2.2.1.3OCTET STRINGread-onlyThe status of the interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
G32 ethIfIntervalInFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.4Gauge32read-onlyThe counter associated with the number of received frames, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalInOctets1.3.6.1.4.1.164.3.1.6.1.2.2.1.5Gauge32read-onlyThe counter associated with the number of received octets, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalAlignmentErrors1.3.6.1.4.1.164.3.1.6.1.2.2.1.6Gauge32read-onlyThe counter associated with the number of received frames, which are not complete (The result of dividing the number of bits by 8 is not an Integer), encountered by the Ethernet interface in the interval.
G32 ethIfIntervalFCSErrors1.3.6.1.4.1.164.3.1.6.1.2.2.1.7Gauge32read-onlyThe counter associated with the number of received frames that didn't pass the FCS test, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalLengthError1.3.6.1.4.1.164.3.1.6.1.2.2.1.8Gauge32read-onlyThe counter associated with the number of received frames with length error, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalOutFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.9Gauge32read-onlyThe counter associated with the number of transmitted frames, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalOutOctets1.3.6.1.4.1.164.3.1.6.1.2.2.1.10Gauge32read-onlyThe counter associated with the number of transmitted octets, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalSingleCollisionFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.11Gauge32read-onlyThe counter associated with the number of successfully transmitted frames for which transmission was inhibited by exactly one collision, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalMultipleCollisionFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.12Gauge32read-onlyThe counter associated with the number of successfully transmitted frames for which transmission was inhibited by more than one collision, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalDeferredTransmissions1.3.6.1.4.1.164.3.1.6.1.2.2.1.13Gauge32read-onlyThe counter associated with the number of transmitted frames for which the first transmission attempt was delayed due to a busy media, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalLateCollisions1.3.6.1.4.1.164.3.1.6.1.2.2.1.14Gauge32read-onlyThe counter associated with the number of times that a collision was detected later than the first 64 bytes of the frame, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalCarrierSenseErrors1.3.6.1.4.1.164.3.1.6.1.2.2.1.15Gauge32read-onlyThe counter associated with the number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalInputCongestionDropped1.3.6.1.4.1.164.3.1.6.1.2.2.1.16Gauge32read-onlyThe counter associated with the number of dropped frames due to a congestion, encountered by the Receive direction to the Ethernet interface in the interval.
G32 ethIfIntervalOutputCongestionDropped1.3.6.1.4.1.164.3.1.6.1.2.2.1.17Gauge32read-onlyThe counter associated with the number of dropped frames due to a congestion, encountered by the Transmit direction to the Ethernet interface in the interval.
G32 ethIfIntervalOverflowInFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.18Gauge32read-onlyThe number of times the associated ethIfIntervalInFrames counter has overflowed in the interval.
G32 ethIfIntervalOverflowInOctets1.3.6.1.4.1.164.3.1.6.1.2.2.1.19Gauge32read-onlyThe number of times the associated ethIfIntervalInOctets counter has overflowed in the interval.
G32 ethIfIntervalOverflowFCSErrors1.3.6.1.4.1.164.3.1.6.1.2.2.1.20Gauge32read-onlyThe number of times the associated ethIfIntervalFCSErrors counter has overflowed in the interval.
G32 ethIfIntervalOverflowOutFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.21Gauge32read-onlyThe number of times the associated ethIfIntervalOutFrames counter has overflowed in the interval.
G32 ethIfIntervalOverflowOutOctets1.3.6.1.4.1.164.3.1.6.1.2.2.1.22Gauge32read-onlyThe number of times the associated ethIfIntervalOutOctets counter has overflowed in the interval.
G32 ethIfIntervalOverflowMultipleCollisionFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.23Gauge32read-onlyThe number of times the associated ethIfIntervalMultipleCollisionFrames counter has overflowed in the interval.
G32 ethIfIntervalInUnicastFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.24Gauge32read-onlyThe number of received Unicast frames, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalOutUnicastFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.25Gauge32read-onlyThe number of transmitted Unicast frames, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalInMulticastFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.26Gauge32read-onlyThe number of received Multicast frames, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalOutMulticastFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.27Gauge32read-onlyThe number of transmitted Multicast frames, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalInBroadcastFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.28Gauge32read-onlyThe number of received Broadcast frames, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalOutBroadcastFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.29Gauge32read-onlyThe number of transmitted Broadcast frames, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalInDiscardFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.30Gauge32read-onlyThe number of received Discarded frames, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalOutDiscardFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.31Gauge32read-onlyThe number of transmitted Discarded frames, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalInPauseFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.32Gauge32read-onlyThe number of received Pause frames, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalOutPauseFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.33Gauge32read-onlyThe number of transmitted Pause frames, encountered by the Ethernet interface in the interval.
G32 ethIfIntervalOverflowInUnicastFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.34Gauge32read-onlyThe number of times the associated ethIfIntervalInUnicastFrames counter has overflowed in the interval.
G32 ethIfIntervalOverflowOutUnicastFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.35Gauge32read-onlyThe number of times the associated ethIfIntervalOutUnicastFrames counter has overflowed in the interval.
G32 ethIfIntervalOverflowInMulticastFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.36Gauge32read-onlyThe number of times the associated ethIfIntervalInMulticastFrames counter has overflowed in the interval.
G32 ethIfIntervalOverflowOutMulticastFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.37Gauge32read-onlyThe number of times the associated ethIfIntervalOutMulticastFrames counter has overflowed in the interval.
G32 ethIfIntervalOverflowInBroadcastFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.38Gauge32read-onlyThe number of times the associated ethIfIntervalInBroadcastFrames counter has overflowed in the interval.
G32 ethIfIntervalOverflowOutBroadcastFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.39Gauge32read-onlyThe number of times the associated ethIfIntervalOutBroadcastFrames counter has overflowed in the interval.
G32 ethIfIntervalOverflowInDiscardFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.40Gauge32read-onlyThe number of times the associated ethIfIntervalInDiscardFrames counter has overflowed in the interval.
G32 ethIfIntervalOverflowOutDiscardFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.41Gauge32read-onlyThe number of times the associated ethIfIntervalOutDiscardFrames counter has overflowed in the interval.
G32 ethIfIntervalOverflowInPauseFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.42Gauge32read-onlyThe number of times the associated ethIfIntervalInPauseFrames counter has overflowed in the interval.
G32 ethIfIntervalOverflowOutPauseFrames1.3.6.1.4.1.164.3.1.6.1.2.2.1.43Gauge32read-onlyThe number of times the associated ethIfIntervalOutPauseFrames counter has overflowed in the interval.
INT ethPerformanceMode1.3.6.1.4.1.164.3.1.6.1.2.3INTEGERread-writeThis object indicates whether OK or Fail statistics will be counted.
ethIfPerfTable1.3.6.1.4.1.164.3.1.6.1.2.4not-accessibleThe Ethernet Performance table.
ethIfPerfEntry1.3.6.1.4.1.164.3.1.6.1.2.4.1not-accessibleAn entry in the Ethernet Performance table.
G32 ethIfPerfInOkFrames1.3.6.1.4.1.164.3.1.6.1.2.4.1.1Gauge32read-onlyThe counter associated with the number of received OK frames, encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) or Reset Statistics was done.
G32 ethIfPerfOutOkFrames1.3.6.1.4.1.164.3.1.6.1.2.4.1.2Gauge32read-onlyThe counter associated with the number of transmitted OK frames, encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) or Reset Statistics was done.
G32 ethIfPerfTotalCollisions1.3.6.1.4.1.164.3.1.6.1.2.4.1.3Gauge32read-onlyThe counter associated with the total number of collisions of any type encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) or Reset Statistics was done
G32 ethIfPerfInOkOctets1.3.6.1.4.1.164.3.1.6.1.2.4.1.4Gauge32read-onlyThe counter associated with the number of received OK Octets, encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) or Reset Statistics was done.
ethIfOamCfm1.3.6.1.4.1.164.3.1.6.1.3
ethIfOamCfmEvents1.3.6.1.4.1.164.3.1.6.1.3.0
NTF ethOamCfmDefectCondition1.3.6.1.4.1.164.3.1.6.1.3.0.1This trap indicates that a MEP has a persistent defect condition.
radMepTable1.3.6.1.4.1.164.3.1.6.1.3.1not-accessibleMEG End Point (MEP) configuration table associated with Maitenance Entity Group (MEG) End Point. MEP is a short name for an expanded ETH flow point that includes a compound ETH Segment flow termination function, which marks the end point of an ETH ME, and a compound ETH Diagnostic flow function.
radMepEntry1.3.6.1.4.1.164.3.1.6.1.3.1.1not-accessibleAn entry in the table.
U32 radOamIdx11.3.6.1.4.1.164.3.1.6.1.3.1.1.1Unsigned32not-accessibleThis object may indicate the Bridge Index or Configuration index.
U32 radOamEvcIdx1.3.6.1.4.1.164.3.1.6.1.3.1.1.2Unsigned32not-accessibleThis object indicates the Index of the EVC (Ethernet Virtual Circuit) that the MEP is associated to.
U32 radMepIdx1.3.6.1.4.1.164.3.1.6.1.3.1.1.3Unsigned32not-accessibleThis object indicates the ID of the MEP being accessed.
ROW radMepRowStatus1.3.6.1.4.1.164.3.1.6.1.3.1.1.4RowStatusread-createThis attribute allows to create/delete a row in this table.
U32 radMepLocalMepId1.3.6.1.4.1.164.3.1.6.1.3.1.1.5Unsigned32read-createThis object indicates the local MEP ID.
U32 radMepRemoteMepId1.3.6.1.4.1.164.3.1.6.1.3.1.1.6Unsigned32read-createThis atribute is currently implemneted at radMepCcTable, that supports multicast.
INT radMepOamMode1.3.6.1.4.1.164.3.1.6.1.3.1.1.7INTEGERread-createThis object determines the OAM mode of the MEP: disabled - no CC is initiated nor responded initiate - the device initiates and responds to CC react - the device does not initiate a CC, but responds to CC.
INT radMepContinuityVerMode1.3.6.1.4.1.164.3.1.6.1.3.1.1.8INTEGERread-createThis object determines the OAM behavior of the MEP: disabled - no CC is done cc_based - CC is done based on incoming messages lb_based - CC is done based on loopback messages.
U32 radMepMeLevel1.3.6.1.4.1.164.3.1.6.1.3.1.1.9Unsigned32read-createAt any point in a network, ME Level is used to distinguish between OAM signals belonging to different nested MEs. Maintenance Entity Levels are defined as follows: 0,1,2 are assigned to customers 3,4 are assigned to providers 5,6,7 are assigned to operators.
INT radMepOamDestAddrType1.3.6.1.4.1.164.3.1.6.1.3.1.1.10INTEGERread-createThis object determines if the OAM messages are sent to user defined unicast address, or to RAD proprietary multicast address.
MAC radMepOamDestMacAddr1.3.6.1.4.1.164.3.1.6.1.3.1.1.11MacAddressread-createThis object determines the MAC address that OAM packets are sent to.
U32 radMepDefaultPriority1.3.6.1.4.1.164.3.1.6.1.3.1.1.12Unsigned32read-createThis object defines the priority of the OAM messages sent when no service is defined on EVC. If a service is defined, the OAM messages will get the highest service priority existing on the EVC.
INT radMepCcStatus1.3.6.1.4.1.164.3.1.6.1.3.1.1.13INTEGERread-onlyThis object indicates the Continuity Check (CC) status.
INT radMepOamProtocol1.3.6.1.4.1.164.3.1.6.1.3.1.1.14INTEGERread-createDetermines whether to use proprietary OAM mechanism, or to use the standard (IEEE 802.1ag, ITU-T Y.1731).
U32 radMepMdId1.3.6.1.4.1.164.3.1.6.1.3.1.1.15Unsigned32read-createThe index of the Maintenance Domain in the radMdTable (radMdIndex).
INT radMepMaFormat1.3.6.1.4.1.164.3.1.6.1.3.1.1.16INTEGERread-createThe type (and thereby format) of the Maintenance Association Name.
OCT radMepMaName1.3.6.1.4.1.164.3.1.6.1.3.1.1.17OCTET STRINGread-createThe Short Maintenance Association name.
U32 radMepSpVlanId1.3.6.1.4.1.164.3.1.6.1.3.1.1.18Unsigned32read-createThe SP (Service Provider) VLAN used when sending an OAM message.
INT radMepCcInterval1.3.6.1.4.1.164.3.1.6.1.3.1.1.19INTEGERread-createIndicates the interval at which CCMs are sent by a MEP Valid only if radMepOamMode = initiate(4).
MAC radMepTransmitLbmDestMacAddress1.3.6.1.4.1.164.3.1.6.1.3.1.1.20MacAddressread-createThe Target MAC Address Field to be transmitted in the Loopback Message: For unicast MAC Address this is the unicast destination MAC address. For multicast MAC Address, this variable is read-only. This address will be used if the value of radMepTransmitLbmDestIsMepId is no (2). 802.1ag clause 12.14.7.3.2:b.
U32 radMepTransmitLbmDestMepId1.3.6.1.4.1.164.3.1.6.1.3.1.1.21Unsigned32read-createThe MEPID of another MEP in the same MA to which the LBM is to be sent. This address will be used if the value of radMepTransmitLbmDestIsMepId is yes (3). 802.1ag clause 12.14.7.3.2:b.
INT radMepTransmitLbmDestIsMepId1.3.6.1.4.1.164.3.1.6.1.3.1.1.22INTEGERread-createyes (3) indicates that MEPID of the target MEP is used for loopback transmission. no (2) indicates that unicast destination MAC address of the target MEP is used. 802.1ag clause 12.14.7.3.2:b.
I32 radMepTransmitLbmMassages1.3.6.1.4.1.164.3.1.6.1.3.1.1.23Integer32read-createThe number of Loopback messages to be transmitted.
U32 radMepTransmitLbmVlanPriority1.3.6.1.4.1.164.3.1.6.1.3.1.1.24Unsigned32read-createThe priority to be used in the VLAN tag, if present, in the transmitted frame. The default value is CCM priority. 802.1ag clause 12.14.7.3.2:e
INT radMepTransmitLbmVlanDropEnable1.3.6.1.4.1.164.3.1.6.1.3.1.1.25INTEGERread-createDrop Enable bit to be used in the VLAN tag, if present, in the transmitted frame. 802.1ag clause 12.14.7.3.2:e
C32 radMepLbrIn1.3.6.1.4.1.164.3.1.6.1.3.1.1.26Counter32read-onlyTotal number of valid, in-order Loopback Replies received.
C32 radMepLbrInOutOfOrder1.3.6.1.4.1.164.3.1.6.1.3.1.1.27Counter32read-onlyThe total number of valid, out-of-order Loopback Replies received.
C32 radMepLbmOut1.3.6.1.4.1.164.3.1.6.1.3.1.1.28Counter32read-onlyTotal number of Loopback Messages transmitted.
MAC radMepTransmitLtmTargetMacAddress1.3.6.1.4.1.164.3.1.6.1.3.1.1.29MacAddressread-createThe Target MAC Address Field to be transmitted in the Link Trace Message: A unicast destination MAC address. This address will be used if the value of radMepTransmitLtmTargetIsMepId is no (2). 802.1ag clause 12.14.7.4.2:c.
U32 radMepTransmitLtmTargetMepId1.3.6.1.4.1.164.3.1.6.1.3.1.1.30Unsigned32read-createThe MEPID of another MEP in the same MA to which LTM is to be transmitted. This address will be used if the value of radMepTransmitLtmTargetIsMepId is yes (3). 802.1ag clause 12.14.7.4.2:c.
INT radMepTransmitLtmTargetIsMepId1.3.6.1.4.1.164.3.1.6.1.3.1.1.31INTEGERread-createyes (3) indicates that MEPID of the target MEP is used for Linktrace transmission. no (2) indicates that unicast destination MAC address of the target MEP is used. 802.1ag clause 12.14.7.4.2:c.
U32 radMepTransmitLtmTtl1.3.6.1.4.1.164.3.1.6.1.3.1.1.32Unsigned32read-createThe LTM TTL field. Default value, if not specified, is 64. The TTL field indicates the number of hops remaining to the LTM. Decremented by 1 each Linktrace Responder that handles the LTM. The value received in the LTM is returned in the LTR. If 0 on input, the LTM is not transmitted to the next hop. 802.1ag clause 12.14.7.4.2:b and 21.8.4.
INT radMepTransmitLtmActivationCmd1.3.6.1.4.1.164.3.1.6.1.3.1.1.33INTEGERread-createActivation command for starting Loop Trace. Set will be always to 'on' value. After operation was finished, Agent will turn the value to 'off'.
ethOamService1.3.6.1.4.1.164.3.1.6.1.3.2
ethOamServiceTable1.3.6.1.4.1.164.3.1.6.1.3.2.1not-accessibleService configuration table associated with Services running on a MEP.
ethOamServiceEntry1.3.6.1.4.1.164.3.1.6.1.3.2.1.1not-accessibleAn entry in the table.
U32 ethOamServiceIdx1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.1Unsigned32not-accessibleThis object indicates the Index of the service being accessed.
ROW ethOamServiceRowStatus1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.2RowStatusread-createThis attribute allows to create/delete a row in this table.
U32 ethOamServicePriority1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.3Unsigned32read-createThis object determines the priority of the service. It is sent as P bits in an OAM message originated by this service.
INT ethOamServicePmEnable1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.4INTEGERread-createThis object determines PM (Performance Monitoring) shall be enabled or not for the service.
I32 ethOamServiceFrameLossRatioThresh1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.5Integer32read-createThis object determines the Frame Loss ratio threshold in exponent of 1/10. That is, a value of 4 means that the threshold is 1E-4.
I32 ethOamServiceDelayThresh1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.6Integer32read-createThis object determines the delay threshold defined for this service, in measurement unit of 0.1 msec.
I32 ethOamServiceDelayVarThresh1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.7Integer32read-createThis object determines the delay variation threshold defined for this service, in measurement unit of 0.1 msec.
I32 ethOamServiceUnavailRatioThresh1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.8Integer32read-createThis object determines the Unavailability ratio threshold in exponent of 1/10. That is, a value of 4 means that the threshold is 1E-4.
C32 ethOamServiceTxFrames1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.9Counter32read-onlyCounts the number of frames trnasmitted by since the time the service is up.
C32 ethOamServiceOverflowTxFrames1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.10Counter32read-onlyThe number of times the associated ethOamServiceTxFrames counter has overflowed.
C32 ethOamServiceFrameLoss1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.11Counter32read-onlyCounts the number of frames lost since the time the service is up.
C32 ethOamServiceOverflowFrameLoss1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.12Counter32read-onlyThe number of times the associated ethOamServiceFrameLoss counter has overflowed.
U32 ethOamServiceFrameLossRatio1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.13Unsigned32read-onlyIndicates the ratio of the lost frames since the time the service is up. The value is the ratio multiplied by 1E10. 0xFFFFFFFF will be returned for ratio greater than 4/10 (40%).
C32 ethOamServiceElapsedTime1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.14Counter32read-onlyIndicates the time elapsed in seconds since the time the service is up.
C32 ethOamServiceUnavailSec1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.15Counter32read-onlyIndicates the number of unavailable seconds since the time the service is up.
U32 ethOamServiceUnavailRatio1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.16Unsigned32read-onlyIndicates the ratio of the unavailable seconds since the time the service is up. The value is the ratio multiplied by 1E10. 0xFFFFFFFF will be returned for ratio greater than 4/10 (40%).
C32 ethOamServiceFramesAboveDelay1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.17Counter32read-onlyIndicates the number of frames arrived with delay greater than the delay threshold.
C32 ethOamServiceOverflowFramesAboveDelay1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.18Counter32read-onlyIndicates the number of times the associated ethOamServiceFramesAboveDelay counter has overflowed.
C32 ethOamServiceFramesAboveDelayVar1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.19Counter32read-onlyIndicates the number of frames arrived with delay variation greater than the delay variation threshold.
C32 ethOamServiceOverflowFramesAboveDelayVar1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.20Counter32read-onlyIndicates the number of times the associated ethOamServiceFramesAboveDelayVar counter has overflowed.
ethOamSvcCurrentStatTable1.3.6.1.4.1.164.3.1.6.1.3.2.2not-accessibleService Current Statistics Table.
ethOamSvcCurrentStatEntry1.3.6.1.4.1.164.3.1.6.1.3.2.2.1not-accessibleCurrent Statistics per service
PER ethOamSvcCurrFramesAboveDelayThresh1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.1PerfCurrentCountread-onlyNumber of frames that arrived in the current interval at a delay greater than the threshold value defined for the service.
PER ethOamSvcCurrFramesBelowDelayThresh1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.2PerfCurrentCountread-onlyNumber of frames that arrived in the current interval at a delay lower than or equal to the threshold value defined for the service.
PER ethOamSvcCurrFramesAboveDVarThresh1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.3PerfCurrentCountread-onlyNumber of frames that arrived in the current interval at a delay variation greater than the threshold value defined for the service.
PER ethOamSvcCurrFramesBelowDVarThresh1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.4PerfCurrentCountread-onlyNumber of frames that arrived in the current interval at a delay variation lower than or equal to the threshold value defined for the service.
PER ethOamSvcCurrFramesTxCounter1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.5PerfCurrentCountread-onlyNumber of trnasmitted frames in the current interval.
PER ethOamSvcCurrFramesLossCounter1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.6PerfCurrentCountread-onlyNumber of lost frames in the current interval.
U32 ethOamSvcCurrMinRoundTripDelay1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.7Unsigned32read-onlyThe mininal value of round trip delay in the current interval. Values units are of 0.1 msec.
U32 ethOamSvcCurrMaxRoundTripDelay1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.8Unsigned32read-onlyThe maximum value of round trip delay in the current interval. Values units are of 0.1 msec.
U32 ethOamSvcCurrAvgRoundTripDelay1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.9Unsigned32read-onlyThe average round trip delay in the current interval. Values units are of 0.1 msec.
U32 ethOamSvcCurrMaxRoundTripDVar1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.10Unsigned32read-onlyThe maximum value of round trip delay variation in the current interval. Values units are of 0.1 msec.
U32 ethOamSvcCurrAvgRoundTripDVar1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.11Unsigned32read-onlyThe average round trip delay variation in the current interval. Values units are of 0.1 msec.
I32 ethOamSvcCurrElapsedTime1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.12Integer32read-onlyThe number of seconds that have elapsed since the beginning of the current interval.
PER ethOamSvcCurrUnavailSec1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.13PerfCurrentCountread-onlyThe number of seconds that the service was unavailable in the current interval.
ethOamSvcIntervalTable1.3.6.1.4.1.164.3.1.6.1.3.2.3not-accessibleService Interval Statistics Table.
ethOamSvcIntervalEntry1.3.6.1.4.1.164.3.1.6.1.3.2.3.1not-accessibleInterval Statistics per service
I32 ethOamSvcIntervalNum1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.1Integer32not-accessibleThe Interval index, which is actualy the Interval number, where 1 is the most recently completed 15 minute interval, and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist).
NUM ethOamSvcIntervalFramesAboveDelayThresh1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.2PerfIntervalCountread-onlyNumber of frames that arrived in a delay greater than the threshold value defined for the service in the selected interval.
NUM ethOamSvcIntervalFramesBelowDelayThresh1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.3PerfIntervalCountread-onlyNumber of frames that arrived in a delay lower than the threshold value defined for the service in the selected interval.
NUM ethOamSvcIntervalFramesAboveDVarThresh1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.4PerfIntervalCountread-onlyNumber of frames that arrived in a delay variation greater than the threshold value defined for the service in the selected interval.
NUM ethOamSvcIntervalFramesBelowDVarThresh1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.5PerfIntervalCountread-onlyNumber of frames that arrived in a delay variation lower than the threshold value defined for the service in the selected interval.
NUM ethOamSvcIntervalFramesTxCounter1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.6PerfIntervalCountread-onlyNumber of trnasmitted frames in the selected interval.
NUM ethOamSvcIntervalFramesLossCounter1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.7PerfIntervalCountread-onlyNumber of lost frames in the selected interval.
U32 ethOamSvcIntervalMinRoundTripDelay1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.8Unsigned32read-onlyThe mininal value of round trip delay in the selected interval. Values units are of 0.1 msec.
U32 ethOamSvcIntervalMaxRoundTripDelay1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.9Unsigned32read-onlyThe maximum value of round trip delay in the selected interval. Values units are of 0.1 msec.
U32 ethOamSvcIntervalAvgRoundTripDelay1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.10Unsigned32read-onlyThe average round trip delay in the selected interval. Values units are of 0.1 msec.
U32 ethOamSvcIntervalMaxRoundTripDVar1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.11Unsigned32read-onlyThe maximum value of round trip delay variation in the selected interval. Values units are of 0.1 msec.
U32 ethOamSvcIntervalAvgRoundTripDVar1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.12Unsigned32read-onlyThe average round trip delay variation in the selected interval. Values units are of 0.1 msec.
NUM ethOamSvcIntervalUnavailSec1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.13PerfIntervalCountread-onlyThe number of seconds that the service was unavailable in the selected interval.
ethOamSvcTotalTable1.3.6.1.4.1.164.3.1.6.1.3.2.4not-accessibleETH OAM Service Total (24H) Statistics Table.
ethOamSvcTotalEntry1.3.6.1.4.1.164.3.1.6.1.3.2.4.1not-accessibleTotal Statistics per service
PER ethOamSvcTotalFramesAboveDelayThresh1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.1PerfTotalCountread-onlyNumber of frames that arrived in a delay greater than the threshold value defined for the service in the last 24H.
PER ethOamSvcTotalFramesBelowDelayThresh1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.2PerfTotalCountread-onlyNumber of frames that arrived in a delay lower than the threshold value defined for the service in the last 24H.
PER ethOamSvcTotalFramesAboveDVarThresh1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.3PerfTotalCountread-onlyNumber of frames that arrived in a delay variation greater than the threshold value defined for the service in the last 24H.
PER ethOamSvcTotalFramesBelowDVarThresh1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.4PerfTotalCountread-onlyNumber of frames that arrived in a delay variation lower than the threshold value defined for the service in the last 24H.
PER ethOamSvcTotalFramesTxCounter1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.5PerfTotalCountread-onlyNumber of trnasmitted frames in the last 24H.
PER ethOamSvcTotalFramesLossCounter1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.6PerfTotalCountread-onlyNumber of lost frames in the last 24H.
U32 ethOamSvcTotalMinRoundTripDelay1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.7Unsigned32read-onlyThe mininal value of round trip delay in the last 24H. Values units are of 0.1 msec.
U32 ethOamSvcTotalMaxRoundTripDelay1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.8Unsigned32read-onlyThe maximum value of round trip delay in the last 24H. Values units are of 0.1 msec.
U32 ethOamSvcTotalAvgRoundTripDelay1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.9Unsigned32read-onlyThe average round trip delay in the last 24H. Values units are of 0.1 msec.
U32 ethOamSvcTotalMaxRoundTripDVar1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.10Unsigned32read-onlyThe maximum value of round trip delay variation in the last 24H. Values units are of 0.1 msec.
U32 ethOamSvcTotalAvgRoundTripDVar1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.11Unsigned32read-onlyThe average round trip delay variation in the last 24H. Values units are of 0.1 msec.
PER ethOamSvcTotalUnavailSec1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.12PerfTotalCountread-onlyThe number of seconds that the service was unavailable in the last 24H.
radMdTable1.3.6.1.4.1.164.3.1.6.1.3.3not-accessibleThe MaintenanceDomain table. Each row in the table represents a different maintenance domain. A Maintenance domain is described in 802.1ag (3.22) as the network or the part of the network for which faults in connectivity are to be managed. The boundary of a Maintenance Domain is defined by a set of DSAPs, each of which can become a point of connectivity to a service instance.
radMdEntry1.3.6.1.4.1.164.3.1.6.1.3.3.1not-accessibleThe Maintenance Domain table entry. This entry is not lost upon reboot. It is backed up by stable storage
U32 radMdIndex1.3.6.1.4.1.164.3.1.6.1.3.3.1.1Unsigned32not-accessibleThe index to the maintenance domain table.
INT radMdFormat1.3.6.1.4.1.164.3.1.6.1.3.3.1.2INTEGERread-createThe type (and thereby format) of the Maintenance Domain Name.
OCT radMdName1.3.6.1.4.1.164.3.1.6.1.3.3.1.3OCTET STRINGread-createThe Maintenance Domain name. The type/format of this object is determined by the value of the radMdNameType object. Each Maintenance Domain has unique name amongst all those used or available to a service provider or operator. It facilitates easy identification of administrative responsibility for each Maintenance Domain.
ROW radMdRowStatus1.3.6.1.4.1.164.3.1.6.1.3.3.1.4RowStatusread-createThis attribute allows to create/delete a row in this table. The writable columns in a row can not be changed if the row is active. All columns must have a valid value before a row can be activated.
radMepLtrTable1.3.6.1.4.1.164.3.1.6.1.3.4not-accessibleThis table contains a list of Linktrace replies received by a specific MEP in response to a linktrace message.
radMepLtrEntry1.3.6.1.4.1.164.3.1.6.1.3.4.1not-accessibleThe LinktraceReply table entry.
U32 radMepLtrReceiveOrder1.3.6.1.4.1.164.3.1.6.1.3.4.1.1Unsigned32not-accessibleAn index to distinguish among multiple LTRs with the same LTR Transaction Identifier field value. radMepLtrReceiveOrder are assigned sequentially from 1, in the order that the Linktrace Initiator received the LTRs.
U32 radMepLtrTtl1.3.6.1.4.1.164.3.1.6.1.3.4.1.2Unsigned32read-onlyTTL field value for a returned LTR.
MAC radMepLtrMacAddr1.3.6.1.4.1.164.3.1.6.1.3.4.1.3MacAddressread-onlyThe MAC address in the header of the returned LTR.
INT radMepLtrRelay1.3.6.1.4.1.164.3.1.6.1.3.4.1.4INTEGERread-onlyThe value returned in the Relay Action field: rlyHit - the LTM reached an MP whose MAC address matches the target MAC address. rlyFdb - the Egress Port was determined by consulting the Filtering Database. rlyMpdb - the Egress Port was determined by consulting the MIP CCM Database. 802.1ag clauses 12.14.7.5.3:g and 20.36.2.5
INT radMepLtrIngress1.3.6.1.4.1.164.3.1.6.1.3.4.1.5INTEGERread-onlyThe value returned in the Ingress Action Field of the LTM. ingNoTlv - no Reply Ingress TLV was returned in the LTM. ingOK - the target data frame would be passed through to the MAC Relay Entity. ingDown - the Bridge Port's MAC_Operational parameter is false. ingBlocked - the target data frame would not be forwarded if received on this port. ingVid - the ingress port is not in the members of the LTM's VID, and ingress filtering is enabled, so the target data frame would be filtered by the ingress filtering. 802.1ag clauses 12.14.7.5.3:k and 20.36.2.6
LLD radMepLtrIngressPortIdSubtype1.3.6.1.4.1.164.3.1.6.1.3.4.1.6LldpPortIdSubtyperead-onlyThe format of the Ingress Port ID. If the radMepLtrIngress object contains the value egrNoTlv(1), then the contents of this object are meaningless. 802.1ag clauses 12.14.7.5.3:m and 20.36.2.8
OCT radMepLtrIngressPortId1.3.6.1.4.1.164.3.1.6.1.3.4.1.7OCTET STRINGread-onlyIngress Port ID. This is an alpha-numeric string that contains a specific identifier for the port. The format of this object is determined by the value of the radMepLtrIngressPortIdSubtype object. If the radMepLtrIngress object contains the value ingNoTlv(1), then the contents of this object are meaningless. 802.1ag clauses 12.14.7.5.3:n and 20.36.2.9
INT radMepLtrEgress1.3.6.1.4.1.164.3.1.6.1.3.4.1.8INTEGERread-onlyThe value returned in the Egress Action Field of the LTM. The value egrNoTlv(1) indicates that no Reply Egress TLV was returned in the LTM. 802.1ag clauses 12.14.7.5.3:o and 20.36.2.10
LLD radMepLtrEgressPortIdSubtype1.3.6.1.4.1.164.3.1.6.1.3.4.1.9LldpPortIdSubtyperead-onlyThe format of the egress Port ID. If the radMepLtrEgress object contains the value egrNoTlv(1), then the contents of this object are meaningless. 802.1ag clauses 12.14.7.5.3:q and 20.36.2.12
OCT radMepLtrEgressPortId1.3.6.1.4.1.164.3.1.6.1.3.4.1.10OCTET STRINGread-onlyEgress Port ID. The format of this object is determined by the value of the radMepLtrEgressPortIdSubtype object. If the radMepLtrEgress object contains the value egrNoTlv(1), then the contents of this object are meaningless. 802.1ag clauses 12.14.7.5.3:r and 20.36.2.13
radMepCcStatusTable1.3.6.1.4.1.164.3.1.6.1.3.5not-accessibleThis table contains a list of CC Status received by a specific MEP from different Remote MEPs.
radMepCcStatusEntry1.3.6.1.4.1.164.3.1.6.1.3.5.1not-accessibleAn entry in the CC Status Table.
U32 radMepRemoteMepIdx1.3.6.1.4.1.164.3.1.6.1.3.5.1.1Unsigned32not-accessibleThis is a running index for arriving CC messages (from different Remote MEPs) for a specific MEP ID.
U32 radMepCcStatusRemMepId1.3.6.1.4.1.164.3.1.6.1.3.5.1.2Unsigned32read-createThis attribute indicates the Remote MEP ID from which the CC messages has arrived.
INT radMepCcStat1.3.6.1.4.1.164.3.1.6.1.3.5.1.3INTEGERread-onlyThis object indicates the Continuity Check (CC) status (ITU-T Y.1731, Appendix I): mismerge - A MEP detects a Mismerge condition when a CCM frame arrives with the correct MEG level, but incorrect MEG ID. unexpectedMep -A MEP detects an Unexpected MEP condition when a CCM frame arrives with the correct MEG level, the correct MEG ID, but an unexpected MEP ID, which includes the MEP's own MEP ID. unexpectedMeLevel - A MEP detects an Unexpected MEG Level condition when a CCM frame arrives with incorrect MEG Level. Incorrect MEG Level is less than the MEP's own MEG level. unexpectedPeriod - A MEP detects an Unexpected Period condition when a CCM frame arrives with a correct MEG level. a correct MEG ID, a correct MEP ID, but with the Period field value different from the MEP's own CCM transmission period. rdi - A MEP detects RDI when it receives a CCM frame with the RDI field set.
MAC radMepCcStatusMacAddr1.3.6.1.4.1.164.3.1.6.1.3.5.1.4MacAddressread-onlyThis object indicates the MAC Address in the CC Status message received.
U32 ethOamStdEtherType1.3.6.1.4.1.164.3.1.6.1.3.6Unsigned32read-writeThe Standard Ether Type in an OAM message. This object will be RW until a formal value will be issued for standard Ethernet Type. When such Standard will exist, this object will be supported RO to reflect the Standard value.
MAC ethOamStdMacAddress1.3.6.1.4.1.164.3.1.6.1.3.7MacAddressread-writeThe Standard MAC Address in an OAM message. This object will be RW until a formal value will be issued for standard MAC Address. When such Standard will exist, this object will be supported RO to reflect the Standard value.
dot1agXCfmMdTable1.3.6.1.4.1.164.3.1.6.1.3.8not-accessibleThe Maintenance Domain table. Each row in the table represents a different maintenance association.
dot1agXCfmMdEntry1.3.6.1.4.1.164.3.1.6.1.3.8.1not-accessibleThe Maintenance Domain table entry.
INT dot1agXCfmMdProtocol1.3.6.1.4.1.164.3.1.6.1.3.8.1.1INTEGERread-create.
dot1agXCfmMepTable1.3.6.1.4.1.164.3.1.6.1.3.9not-accessibleThe Maintenance Association End Point (MEP) table.
dot1agXCfmMepEntry1.3.6.1.4.1.164.3.1.6.1.3.9.1not-accessibleThe MEP table entry
INT dot1agXCfmMepContinuityVerMode1.3.6.1.4.1.164.3.1.6.1.3.9.1.1INTEGERread-createThis object determines the OAM behavior of the MEP: disabled - no Continuity Verification is done cc_based - Continuity Verification is done based on incoming CC messages lb_based - Continuity Verification is done based on loopback messages.
INT dot1agXCfmMepDestAddrType1.3.6.1.4.1.164.3.1.6.1.3.9.1.2INTEGERread-createThis object determines if the OAM messages are sent to user defined unicast address, or to RAD proprietary multicast address.
MAC dot1agXCfmMepDestMacAddr1.3.6.1.4.1.164.3.1.6.1.3.9.1.3MacAddressread-createThis object determines the MAC address that OAM packets are sent to.
dot1agXCfmMepDbTable1.3.6.1.4.1.164.3.1.6.1.3.10not-accessibleThe MEP DB table
dot1agXCfmMepDbEntry1.3.6.1.4.1.164.3.1.6.1.3.10.1not-accessibleThe MEP Database table entry.
INT dot1agXCfmMepCcStat1.3.6.1.4.1.164.3.1.6.1.3.10.1.1INTEGERread-onlyThis object indicates the Continuity Check (CC) status (ITU-T Y.1731, Appendix I): mismerge - A MEP detects a Mismerge condition when a CCM frame arrives with the correct MEG level, but incorrect MEG ID. unexpectedMep -A MEP detects an Unexpected MEP condition when a CCM frame arrives with the correct MEG level, the correct MEG ID, but an unexpected MEP ID, which includes the MEP's own MEP ID. unexpectedMeLevel - A MEP detects an Unexpected MEG Level condition when a CCM frame arrives with incorrect MEG Level. Incorrect MEG Level is less than the MEP's own MEG level. unexpectedPeriod - A MEP detects an Unexpected Period condition when a CCM frame arrives with a correct MEG level. a correct MEG ID, a correct MEP ID, but with the Period field value different from the MEP's own CCM transmission period. rdi - A MEP detects RDI when it receives a CCM frame with the RDI field set.
ethIfRing1.3.6.1.4.1.164.3.1.6.1.4
ethIfRingEvents1.3.6.1.4.1.164.3.1.6.1.4.0
NTF ethIfRingStatusChange1.3.6.1.4.1.164.3.1.6.1.4.0.1This trap indicates that the status of the Ethernet Ring has been changed.
ethIfRingTable1.3.6.1.4.1.164.3.1.6.1.4.1not-accessibleEthernet Ring Table.
ethIfRingEntry1.3.6.1.4.1.164.3.1.6.1.4.1.1not-accessibleAn entry in the table.
U32 ethIfRingIdx1.3.6.1.4.1.164.3.1.6.1.4.1.1.1Unsigned32not-accessibleThis object is an Index that can indicate Slot, Ring, Cnfg etc., according to the device used. When NA, 1 will be used.
INT ethIfRingAdminStatus1.3.6.1.4.1.164.3.1.6.1.4.1.1.2INTEGERread-writeThis object denotes the Ethernet Ring administrative status.
POR ethIfRingPorts1.3.6.1.4.1.164.3.1.6.1.4.1.1.3PortListread-writeThe set of ports which are assigned to be ring members. The default value of this object is a string of zeros.
INT ethIfRingOperStatus1.3.6.1.4.1.164.3.1.6.1.4.1.1.4INTEGERread-onlyThis object indicates the Ethernet Ring operational status.
U32 ethIfRingKeepAliveInterval1.3.6.1.4.1.164.3.1.6.1.4.1.1.5Unsigned32read-writeThis parameter indicates the period of time (in msec.) between two consequent Keep Alive messages.
U32 ethIfRingKeepAliveThresh1.3.6.1.4.1.164.3.1.6.1.4.1.1.6Unsigned32read-writeThis parameter indicates the maximum number of missed Keep Alive answer messages acceptable, after which link status will be failed.
U32 ethIfRingKeepAliveVlanId1.3.6.1.4.1.164.3.1.6.1.4.1.1.7Unsigned32read-writeDedicated VLAN ID for keep alive messages.
U32 ethIfRingMultiCastVlanId1.3.6.1.4.1.164.3.1.6.1.4.1.1.8Unsigned32read-writeDedicated VLAN ID for multicast messages.
INT ethIfRingRowStatus1.3.6.1.4.1.164.3.1.6.1.4.1.1.9INTEGERread-writeImplement creation/deletion of rings in the device.
ethIfStorming1.3.6.1.4.1.164.3.1.6.1.5
ethIfStormTable1.3.6.1.4.1.164.3.1.6.1.5.1not-accessibleEthernet Storming Table.
ethIfStormEntry1.3.6.1.4.1.164.3.1.6.1.5.1.1not-accessibleAn entry in the table.
U32 ethIfStormCnfgIdx1.3.6.1.4.1.164.3.1.6.1.5.1.1.1Unsigned32not-accessibleThis attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
U32 ethIfStormIfIdx1.3.6.1.4.1.164.3.1.6.1.5.1.1.2Unsigned32not-accessibleA unique index of the ethernet interface/port.
INT ethIfStormDirection1.3.6.1.4.1.164.3.1.6.1.5.1.1.3INTEGERnot-accessibleThis object indicates the port's Storm Direction.
BIT ethIfStormPacketType1.3.6.1.4.1.164.3.1.6.1.5.1.1.4Bitsnot-accessiblePacket Type on which Storming operations will be performed.
INT ethIfStormCtrlEnable1.3.6.1.4.1.164.3.1.6.1.5.1.1.5INTEGERread-writeThis object indicates if the Storm Controling is Enabled or Disabled for the relevant entry.
U32 ethIfStormMaxRate1.3.6.1.4.1.164.3.1.6.1.5.1.1.6Unsigned32read-writeThis object indicates the Maximum Rate at which Storming packets are forwarded, in Kbps.For some devices the units are PPS(Packets Per Second ) or kilobytes per second.
ethIfOamEfm1.3.6.1.4.1.164.3.1.6.1.6
dot3OamEvents1.3.6.1.4.1.164.3.1.6.1.6.0
NTF dot3OamOperStatusChange1.3.6.1.4.1.164.3.1.6.1.6.0.1This trap is sent when OAM EFM Link goes Up or Down. Up - is considered when dot3OamOperStatus value changes to operational(9) from any other value. Down - is considered when dot3OamOperStatus value changes from operational(9) to any other value.
NTF dot3OamPeerEvent1.3.6.1.4.1.164.3.1.6.1.6.0.2This trap is sent when value of dot3OamXPeerState changes from any value to one of the following values: linkFault, dyingGasp, criticalEvent. This trap has no recovery (clearing value).
dot3OamDescrTable1.3.6.1.4.1.164.3.1.6.1.6.1not-accessibleThis table supports definitions of Descriptors (profiles) of OAM EFM Links.
dot3OamDescrEntry1.3.6.1.4.1.164.3.1.6.1.6.1.1not-accessibleEach entry corresponds to a single OAM EFM Descriptor (profile). Each Descriptor contains a set of OAM EFM Link configuration parameters. The configuration parameters are applied to the OAM EFM Links referencing this Descriptor (see dot3OamXDescrId object). Descriptors may be created/deleted using the row creation/deletion mechanism via dot3OamDescrRowStatus. If an active entry is referenced in dot3OamXDescrId, the entry MUST remain active until all references are removed.
U32 dot3OamDescrId1.3.6.1.4.1.164.3.1.6.1.6.1.1.1Unsigned32not-accessibleThis object is the unique index associated with this Descriptor (profile). Entries in this table are referenced via the object dot3OamXDescrId in dot3OamXEntry.
ROW dot3OamDescrRowStatus1.3.6.1.4.1.164.3.1.6.1.6.1.1.2RowStatusread-createThis object controls creation/deletion of the associated entry in this table per the semantics of RowStatus. If an active entry is referenced in dot3OamXDescrId, the entry MUST remain active until all references are removed.
INT dot3OamDescrMode1.3.6.1.4.1.164.3.1.6.1.6.1.1.3INTEGERread-createThis object controls the mode of OAM operation for an Ethernet-like interface referencing this Descriptor. OAM on Ethernet interfaces may be in 'active' mode or 'passive' mode. These two modes differ in that active mode provides additional capabilities to initiate monitoring activities with the remote OAM peer entity, while passive mode generally waits for the peer to initiate OAM actions with it. As an example, an active OAM entity can put the remote OAM entity in a loopback state, where a passive OAM entity cannot.
INT dot3OamDescrLbRxOperation1.3.6.1.4.1.164.3.1.6.1.6.1.1.4INTEGERread-createSince OAM loopback is a disruptive operation (user traffic does not pass), this object provides a mechanism to provide control: whether received OAM loopback commands are processed or ignored, for the OAM Link referencing this Descriptor. When the value is ignore(1), received loopback commands are ignored. When the value is process(2), received loopback commands are processed. The default value is to ignore loopback commands (ignore(1)).
U32 dot3OamDescrRateLimit1.3.6.1.4.1.164.3.1.6.1.6.1.1.5Unsigned32read-createThis object defines how many OAM frames can be sent per second (maximum) for an OAM EFM Link referencing this Descriptor.
dot3OamXTable1.3.6.1.4.1.164.3.1.6.1.6.2not-accessibleThis table is an extension of dot3OamTable of standard DOT3-OAM-MIB.
dot3OamXEntry1.3.6.1.4.1.164.3.1.6.1.6.2.1not-accessibleAn entry in dot3OamXTable.
U32 dot3OamXDescrId1.3.6.1.4.1.164.3.1.6.1.6.2.1.1Unsigned32read-writeThis object points to an entry of dot3OamDescrTable (dot3OamDescrId), which defines part of the configuration parameters for this OAM EFM Link. As long as one of the OAM EFM Links refers an entry in the dot3OamDescrTable, this entry cannot be removed. When an OAM EFM Link supports this object (RW), the standard MIB objects of: dot3OamMode (parallel to dot3OamDescrMode) and dot3OamLoopbackIgnoreRx (parallel to dot3OamDescrLbRxOperation) will be supported by Agent RO.
INT dot3OamXPeerState1.3.6.1.4.1.164.3.1.6.1.6.2.1.2INTEGERread-onlyThis object reports the state of the Peer of the OAM EFM Link. unknown - at the initialization of the device, or after Reset, when there is still no data about the peer's state. operational - usually after unknown state, when device senses that peer is OK. linkFault - Loss of Signal is detected by the receiver. dyingGasp - Unrecoverable condition has occurred (e.g power failure) criticalEvent - Unspecified Critical Event has occured.
ethIfMacLayer1.3.6.1.4.1.164.3.1.6.1.7
ethIfMacLayerEvents1.3.6.1.4.1.164.3.1.6.1.7.0
NTF ethIfMacAccessViolation1.3.6.1.4.1.164.3.1.6.1.7.0.1This trap indicates that an Access Violation occurred.
ethIfSrcMacCtrlTable1.3.6.1.4.1.164.3.1.6.1.7.1not-accessibleThis table supports source MAC addresses control parameters per interface. Source MAC control will be used mainly for security. Only packets with certain source MAC Addresses will be allowed to access the device. The source MAC addresses can be static or learned. The static addresses will be defined by the user in another table: ethIfSrcMacCtrlAddrTable. The learned addresses will exist in the ethIfSrcMacCtrlAddrTable as well.
ethIfSrcMacCtrlEntry1.3.6.1.4.1.164.3.1.6.1.7.1.1not-accessibleAn entry in the table.
U32 ethIfSrcMacCtrlIndex1.3.6.1.4.1.164.3.1.6.1.7.1.1.1Unsigned32not-accessibleThe index of the MAC Layer interface supporting source MAC control feature. It may be the ifIndex of the ETH/Bridge Port.
U32 ethIfSrcMacCtrlIdx21.3.6.1.4.1.164.3.1.6.1.7.1.1.2Unsigned32not-accessibleA second index that can be used. For example: The VLAN ID for which the source MAC control feature is supported. When this index is not in use, its value will be: 9999.
INT ethIfSrcMacCtrl1.3.6.1.4.1.164.3.1.6.1.7.1.1.3INTEGERread-writeEnable or disable the source MAC control on the current interface. The device should not enable source MAC control if for the current interface there are more than ethIfSrcMacCtrlMaxPermitAddr addresses in the ethIfSrcMacCtrlAddrTable. Default value will be: disable (2).
U32 ethIfSrcMacCtrlMaxPermitAddr1.3.6.1.4.1.164.3.1.6.1.7.1.1.4Unsigned32read-writeThis is the maximum number of permitted MAC addresses (static and learned) for the current interface.
U32 ethIfSrcMacCtrlCurNumPermitAddr1.3.6.1.4.1.164.3.1.6.1.7.1.1.5Unsigned32read-onlyThis is the number of source MAC addresses currently permitted for the current interface.
INT ethIfSrcMacCtrlFlushAddrCmd1.3.6.1.4.1.164.3.1.6.1.7.1.1.6INTEGERread-writeWhen set to on (3) this command will erase all the learned addresses and invalid addresses of the selected interface in the ethIfSrcMacCtrlAddrTable. After operation is finished, Agent will turn the value to 'off'.
U32 ethIfSrcMacCtrlAging1.3.6.1.4.1.164.3.1.6.1.7.1.1.7Unsigned32read-writeThe timeout period in seconds for aging out dynamically learned source MAC addresses. Valid Values: 0 - disable 10-1000000
INT ethIfSrcMacCtrlLocking1.3.6.1.4.1.164.3.1.6.1.7.1.1.8INTEGERread-writeWhen set to lock (3) this command will lock the Source MAC Address learning. No more learned addresses will be added to the ethIfSrcMacCtrlAddrTable. When set to unlock (2) this command will unlock the Source MAC Address learning. Learned addresses will be added to the ethIfSrcMacCtrlAddrTable but the number of addresses in the table will not exceed ethIfSrcMacCtrlMaxPermitAddr. Default value is: unlock (2).
INT ethIfSrcMacCtrlViolationAction1.3.6.1.4.1.164.3.1.6.1.7.1.1.9INTEGERread-writeDetermines the action that the device will take upon security violation. drop(2) - the violating packets will be dropped. dropNotify (3)- the violating packets will be dropped and notifications will be generated. Notifications may be for example: SNMP Traps, Syslog messages and log file new entries. shutdown (4) - the interface will be forced to shut down.
MAC ethIfSrcMacCtrlLastViolatingAddr1.3.6.1.4.1.164.3.1.6.1.7.1.1.10MacAddressread-writeThis object indicates the last MAC address that violated the security on the current interface. If no violation, the agent will return: 00-00-00-00-00-00 .
INT ethIfSrcMacCtrlPortStatus1.3.6.1.4.1.164.3.1.6.1.7.1.1.11INTEGERread-onlyThis object represents the operational status of the MAC Control feature on an interface. shutdown(2) - This indicates that the port is shutdown due to security violation. secureActive (3) - This indicates that the MAC Control interface security is operational and this interface is not shutdown due to security violation. secureInactive (4)- This indicates that the MAC Control is not operational.
ethIfSrcMacCtrlAddrTable1.3.6.1.4.1.164.3.1.6.1.7.2not-accessibleThis table shows which MAC Addresses are permitted when the source MAC control is enabled and which non permitted MAC Addresses attempted to access the current interface. It contains static source MAC Addresses as well as learned MAC Addresses. The user can configure Static permitted source MAC Addresses via this table.
ethIfSrcMacCtrlAddrEntry1.3.6.1.4.1.164.3.1.6.1.7.2.1not-accessibleAn entry in the table.
U32 ethIfSrcMacCtrlAddrIndex1.3.6.1.4.1.164.3.1.6.1.7.2.1.1Unsigned32not-accessibleThe index of the interface for which the source MAC addresses exist in this table. It may be the ifIndex of the ETH/Bridge Port.
MAC ethIfSrcMacCtrlAddr1.3.6.1.4.1.164.3.1.6.1.7.2.1.2MacAddressnot-accessibleA unicast source MAC address that was learned or statically configured for the current interface. Packets with this source MAC address will be accepted by the device.
U32 ethIfSrcMacCtrlAddrIdx31.3.6.1.4.1.164.3.1.6.1.7.2.1.3Unsigned32not-accessibleA third index that can be used. For example: The VLAN ID for which the source MAC control feature is supported. When this index is not in use, its value will be: 9999.
INT ethIfSrcMacCtrlAddrRowStatus1.3.6.1.4.1.164.3.1.6.1.7.2.1.4INTEGERread-writeThis MIB object will be used in order to create/delete a static row or delete an address that is not allowed to access the current interface (ethIfSrcMacCtrlAddrStatus= invalid(2)). Device will add the learned addresses to this table. It will not be possible to add a new static entry to this table while the number of existing rows is equal or more than ethIfSrcMacCtrlMaxPermitAddr. When ethIfSrcMacCtrl = enabled (3), the device will add learned entries only up to ethIfSrcMacCtrlMaxPermitAddr.
INT ethIfSrcMacCtrlAddrStatus1.3.6.1.4.1.164.3.1.6.1.7.2.1.5INTEGERread-onlyThe status of this entry. The meanings of the values are: invalid (2) - the current address is not allowed to access this interface. learned(3) - the current address was learned. mgmt (5) - the current address is static. It may exist in the MAC Table.
ds3Interface1.3.6.1.4.1.164.3.1.6.3
prtDs3PerfHistory1.3.6.1.4.1.164.3.1.6.3.1
prtSDs3IfTable1.3.6.1.4.1.164.3.1.6.3.1.1not-accessibleThe DS3 interface table.
prtDs3IfEntry1.3.6.1.4.1.164.3.1.6.3.1.1.1not-accessibleAn entry in the DS3 interface table.
I32 prtDs3IfTimeElapsed1.3.6.1.4.1.164.3.1.6.3.1.1.1.1Integer32read-onlyThe number of seconds that have elapsed since the beginning of the near end current error- measurement period.
I32 prtDs3IfValidIntervals1.3.6.1.4.1.164.3.1.6.3.1.1.1.2Integer32read-onlyThe number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online.
prtDs3CurrentTable1.3.6.1.4.1.164.3.1.6.3.1.2not-accessibleThe DS3 Current table.
prtDs3CurrentEntry1.3.6.1.4.1.164.3.1.6.3.1.2.1not-accessibleAn entry in the DS3 Current table.
G32 prtDs3CurrentLOS1.3.6.1.4.1.164.3.1.6.3.1.2.1.1Gauge32read-onlyThe counter associated with the number of LOS seconds, encountered by a DS3 interface in the current 15 minute interval.
G32 prtDs3CurrentOOF1.3.6.1.4.1.164.3.1.6.3.1.2.1.2Gauge32read-onlyThe counter associated with the number of OOF seconds, encountered by a DS3 interface in the current 15 minute interval.
G32 prtDs3CurrentLOC1.3.6.1.4.1.164.3.1.6.3.1.2.1.3Gauge32read-onlyThe counter associated with the number of LOC seconds, encountered by a DS3 interface in the current 15 minute interval.
G32 prtDs3CurrentAIS1.3.6.1.4.1.164.3.1.6.3.1.2.1.4Gauge32read-onlyThe counter associated with the number of AIS seconds, encountered by a DS3 interface in the current 15 minute interval.
G32 prtDs3CurrentRDI1.3.6.1.4.1.164.3.1.6.3.1.2.1.5Gauge32read-onlyThe counter associated with the number of RDI seconds, encountered by a DS3 interface.
G32 prtDs3CurrentUAS1.3.6.1.4.1.164.3.1.6.3.1.2.1.6Gauge32read-onlyThe counter associated with the number of UAS, encountered by a SONET interface.
G32 prtDs3CurrentBIP1.3.6.1.4.1.164.3.1.6.3.1.2.1.7Gauge32read-onlyThe counter associated with the number of BIP errors, encountered by a DS3 interface in the current 15 minute interval.
G32 prtDs3CurrentFEBE1.3.6.1.4.1.164.3.1.6.3.1.2.1.8Gauge32read-onlyThe counter associated with the number of FEBE errors, encountered by a DS3 interface in the current 15 minute interval.
G32 prtDs3CurrentSLM1.3.6.1.4.1.164.3.1.6.3.1.2.1.9Gauge32read-onlyThe counter associated with the number of SLM seconds, encountered by an E3 (only ) interface in the current 15 minute interval.
G32 prtDs3CurrentSES1.3.6.1.4.1.164.3.1.6.3.1.2.1.10Gauge32read-onlyThe counter associated with the number of SES encountered by a E3 interface in the current 15 minute interval.
G32 prtDs3CurrentES1.3.6.1.4.1.164.3.1.6.3.1.2.1.11Gauge32read-onlyThe number of Errored Seconds, encountered by a DS3 interface in the current 15 minute interval.
G32 prtDs3CurrentBitParity1.3.6.1.4.1.164.3.1.6.3.1.2.1.12Gauge32read-onlyBit Parity Error counter. Relevant to T3 only.
G32 prtDs3CurrentPlcpLOF1.3.6.1.4.1.164.3.1.6.3.1.2.1.13Gauge32read-onlyThe counter associated with the number of LOF seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals. This counter is relevant for plcpInternal(5) or plcpExternal(6) configuration If frame types only.
G32 prtDs3CurrentPlcpRAI1.3.6.1.4.1.164.3.1.6.3.1.2.1.14Gauge32read-onlyReceiving Yellow/Remote Alarm Indication. This counter is relevant for PLCP (external/internal) frame types only.
G32 prtDs3CurrentPlcpBIP1.3.6.1.4.1.164.3.1.6.3.1.2.1.15Gauge32read-onlyThe counter associated with the number of BIP errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only.
G32 prtDs3CurrentPlcpFEBE1.3.6.1.4.1.164.3.1.6.3.1.2.1.16Gauge32read-onlyThe counter associated with the number of FEBE errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only.
G32 prtDs3CurrentBPV1.3.6.1.4.1.164.3.1.6.3.1.2.1.17Gauge32read-onlyNumber of BPVs (Bi-Polar Violations) , encountered by a DS3 interface in the current 15 minute interval. This object is relevant only for Electrical Line of Fomi-E3/T3.
G32 prtDs3CurrentLCE1.3.6.1.4.1.164.3.1.6.3.1.2.1.18Gauge32read-onlyNumber of LCE (Link Code Errors) encountered by a DS3 interface in the current 15 minute interval. This object is relevant only for Optical Links of Fomi-E3/T3.
OCT prtDs3CurrentStatus1.3.6.1.4.1.164.3.1.6.3.1.2.1.19OCTET STRINGread-onlyThe statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
prtDs3IntervalTable1.3.6.1.4.1.164.3.1.6.3.1.3not-accessibleThe DS3 Interval table.
prtDs3IntervalEntry1.3.6.1.4.1.164.3.1.6.3.1.3.1not-accessibleAn entry in the DS3 Interval table.
I32 prtDs3IntervalNumber1.3.6.1.4.1.164.3.1.6.3.1.3.1.1Integer32read-onlyA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
G32 prtDs3IntervalLOS1.3.6.1.4.1.164.3.1.6.3.1.3.1.2Gauge32read-onlyThe counter associated with the number of LOS seconds , encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
G32 prtDs3IntervalOOF1.3.6.1.4.1.164.3.1.6.3.1.3.1.3Gauge32read-onlyThe counter associated with the number of OOF seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
G32 prtDs3IntervalLOC1.3.6.1.4.1.164.3.1.6.3.1.3.1.4Gauge32read-onlyThe counter associated with the number of LOC seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
G32 prtDs3IntervalAIS1.3.6.1.4.1.164.3.1.6.3.1.3.1.5Gauge32read-onlyThe counter associated with the number of AIS seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
G32 prtDs3IntervalRDI1.3.6.1.4.1.164.3.1.6.3.1.3.1.6Gauge32read-onlyThe counter associated with the number of RDI seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
G32 prtDs3IntervalUAS1.3.6.1.4.1.164.3.1.6.3.1.3.1.7Gauge32read-onlyThe counter associated with the number of UAS, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
G32 prtDs3IntervalBIP1.3.6.1.4.1.164.3.1.6.3.1.3.1.8Gauge32read-onlyThe counter associated with the number of BIP errors, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
G32 prtDs3IntervalFEBE1.3.6.1.4.1.164.3.1.6.3.1.3.1.9Gauge32read-onlyThe counter associated with the number of FEBE errors, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
G32 prtDs3IntervalSLM1.3.6.1.4.1.164.3.1.6.3.1.3.1.10Gauge32read-onlyThe counter associated with the number of SLM seconds, encountered by an E3 interface in one of the previous 96, individual 15 minute, intervals.
G32 prtDs3IntervalSES1.3.6.1.4.1.164.3.1.6.3.1.3.1.11Gauge32read-onlyThe counter associated with the number of SES encountered by a E3 interface in one of the previous 96, individual 15 minute, intervals.
G32 prtDs3IntervalES1.3.6.1.4.1.164.3.1.6.3.1.3.1.12Gauge32read-onlyThe number of Errored Seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
G32 prtDs3IntervalBitParity1.3.6.1.4.1.164.3.1.6.3.1.3.1.13Gauge32read-onlyBit Parity Error counter. Relevant to T3 only.
G32 prtDs3IntervalPlcpLOF1.3.6.1.4.1.164.3.1.6.3.1.3.1.14Gauge32read-onlyThe counter associated with the number of LOF seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals. This counter is relevant for plcpInternal(5) or plcpExternal(6) configuration If frame types only.
G32 prtDs3IntervalPlcpRAI1.3.6.1.4.1.164.3.1.6.3.1.3.1.15Gauge32read-onlyReceiving Yellow/Remote Alarm Indication. This counter is relevant for PLCP (external/internal) frame types only.
G32 prtDs3IntervalPlcpBIP1.3.6.1.4.1.164.3.1.6.3.1.3.1.16Gauge32read-onlyThe counter associated with the number of BIP errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only.
G32 prtDs3IntervalPlcpFEBE1.3.6.1.4.1.164.3.1.6.3.1.3.1.17Gauge32read-onlyThe counter associated with the number of FEBE errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only.
G32 prtDs3IntervalBPV1.3.6.1.4.1.164.3.1.6.3.1.3.1.18Gauge32read-onlyNumber of BPVs (Bi-Polar Violations) , encountered by a DS3 interface in the specified 15 minute interval. This object is relevant only for Electrical Line of Fomi-E3/T3.
G32 prtDs3IntervalLCE1.3.6.1.4.1.164.3.1.6.3.1.3.1.19Gauge32read-onlyNumber of LCE (Link Code Errors) encountered by a DS3 interface in the specified 15 minute interval. This object is relevant only for Optical Links of Fomi-E3/T3.
OCT prtDs3IntervalStatus1.3.6.1.4.1.164.3.1.6.3.1.3.1.20OCTET STRINGread-onlyThe statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
prtDs3TotalTable1.3.6.1.4.1.164.3.1.6.3.1.4not-accessibleA list of Total entries.
prtDs3TotalEntry1.3.6.1.4.1.164.3.1.6.3.1.4.1not-accessibleAn entry of Total table.
G32 prtDs3TotalUAS1.3.6.1.4.1.164.3.1.6.3.1.4.1.6Gauge32read-onlyNumber of UASs (Unavailable Seconds) , encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0.
G32 prtDs3TotalBPV1.3.6.1.4.1.164.3.1.6.3.1.4.1.17Gauge32read-onlyNumber of BPVs (Bi-Polar Violations) , encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0.
G32 prtDs3TotalLCE1.3.6.1.4.1.164.3.1.6.3.1.4.1.18Gauge32read-onlyNumber of LCE (Link Code Errors) encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0.
G32 prtDs3TotalSES1.3.6.1.4.1.164.3.1.6.3.1.4.1.19Gauge32read-onlyNumber of SES (Severely Errored Seconds) encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0.
dsx3XConfigTable1.3.6.1.4.1.164.3.1.6.3.2not-accessibleAn extension to the DS3 Configuration table.
dsx3XConfigEntry1.3.6.1.4.1.164.3.1.6.3.2.1not-accessibleAn entry containing additional configuration parameters.
INT dsx3AisEnable1.3.6.1.4.1.164.3.1.6.3.2.1.1INTEGERread-writeEnable/ disable AIS transmit when Ethernet (for TDMoIP) line is disconnected.
INT dsx3TxClockSource1.3.6.1.4.1.164.3.1.6.3.2.1.2INTEGERread-writeThe source of Transmit Clock. loopTiming indicates that the recovered receive clock is used as the transmit clock. localTiming indicates that a local clock source is used or that an external clock is attached to the box containing the interface. throughTiming indicates that transmit clock is derived from the recovered receive clock of another DS3 interface. 'system' indicates that the system clock is used as the transmit clock.
dsx3MappingTable1.3.6.1.4.1.164.3.1.6.3.3not-accessibleThe DS3/E3 mapping table associates DS3/E3 channels with logical or physical interfaces. For example, consider a DS3 device with 16 T1's and 1 VCG. There are 28 logical/internal channels, numbered 1 through 28 but only 17 are actually connected. We might describe the allocation of channels, in the dsx3MappingTable, as follows: dsx3MappingIfIndex.1. 1 = 1001 dsx3MappingIfIndex.1.15 = 1015 dsx3MappingIfIndex.1. 2 = 1002 dsx3MappingIfIndex.1.16 = 1016 dsx3MappingIfIndex.1. 3 = 1003 dsx3MappingIfIndex.1.17 = 1017 dsx3MappingIfIndex.1. 4 = 1004 dsx3MappingIfIndex.1.18 = 0 dsx3MappingIfIndex.1. 5 = 1005 dsx3MappingIfIndex.1.19 = 0 dsx3MappingIfIndex.1. 6 = 1006 dsx3MappingIfIndex.1.20 = 0 dsx3MappingIfIndex.1. 7 = 1007 dsx3MappingIfIndex.1.21 = 0 dsx3MappingIfIndex.1. 8 = 1008 dsx3MappingIfIndex.1.22 = 0 dsx3MappingIfIndex.1. 9 = 1009 dsx3MappingIfIndex.1.23 = 0 dsx3MappingIfIndex.1.10 = 1010 dsx3MappingIfIndex.1.24 = 0 dsx3MappingIfIndex.1.11 = 1011 dsx3MappingIfIndex.1.25 = 0 dsx3MappingIfIndex.1.12 = 1012 dsx3MappingIfIndex.1.26 = 0 dsx3MappingIfIndex.1.13 = 1013 dsx3MappingIfIndex.1.27 = 0 dsx3MappingIfIndex.1.14 = 1014 dsx3MappingIfIndex.1.28 = 0 Note that in the case above all channels are mapped to one T3 port with ifIndex = 1. The Channels 1...28 are represented via the 2nd index. The values of 1001...1016 are the T1 interface ifIndexes. The value of 1017 is the ifIndex of the VCG. Unconnected channels have a value of 0.
dsx3MappingEntry1.3.6.1.4.1.164.3.1.6.3.3.1not-accessibleAn entry in the DS3 mapping table.
NUM dsx3MappingDs3Index1.3.6.1.4.1.164.3.1.6.3.3.1.1InterfaceIndexnot-accessibleThe index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. This value is also equal to dsx3LineIndex used in dsx3ConfigEntry. For RICi-16 this is the ifIndex of the T3 interface.
U32 dsx3MappingNumber1.3.6.1.4.1.164.3.1.6.3.3.1.2Unsigned32not-accessibleThe channel number for this entry. For RICi-16 this is the channel number 1...28.
NUM dsx3MappingIfIndex1.3.6.1.4.1.164.3.1.6.3.3.1.3InterfaceIndexread-writeAn index value that uniquely identifies a logical or physical interface mapped to a DS3/E3 channel. If no interface is currently using a channel, the value should be zero. If a single interface occupies more than one channel, that ifIndex value will be found in multiple channels. For RICi-16 this is the ifIndex of the T1 or VCG interface.
ds1Interface1.3.6.1.4.1.164.3.1.6.4
prtDS1Events1.3.6.1.4.1.164.3.1.6.4.0
NTF ds1LocalMultiframeAlarmTrap1.3.6.1.4.1.164.3.1.6.4.0.1This trap indicates near end (Local) Loss of Multiframe Alignment, of the user E1 interface.
NTF ds1RemoteMultiframeAlarmTrap1.3.6.1.4.1.164.3.1.6.4.0.2This trap indicates that the far end (remote) unit, connected to the user E1 interface, reports Loss of Multiframe Alignment.
NTF ds1LinkFrameSlipTrap1.3.6.1.4.1.164.3.1.6.4.0.3This trap indicates that a Frame Slip occurred at the user DS1 interface. This usually indicates timing problems (incorrect selection of timing reference), on the user DS1 link.
NTF ds1BpvErrorTrap1.3.6.1.4.1.164.3.1.6.4.0.4This trap indicates a Bipolar Violation (BPV) error has been detected at the user DS1 interface.
NTF ds1ExcessiveBpvTrap1.3.6.1.4.1.164.3.1.6.4.0.5This trap indicates excessive number of Bipolar Violation errors (BPV) detected by the user DS1 interface
NTF ds1Crc4ErrorTrap1.3.6.1.4.1.164.3.1.6.4.0.6This trap indicates that a frame with CRC-4 error has been detected at the user DS1 interface.
NTF ds1ExcessiveErrorRatioTrap1.3.6.1.4.1.164.3.1.6.4.0.7This trap indicates that the error rate, detected at the user DS1 interface, on the frame synchronization bits is high, as defined by ITU-T Rec. G.732.
NTF ds1RemoteSyncLossTrap1.3.6.1.4.1.164.3.1.6.4.0.8This trap indicates that the far-end (remote) unit, connected to user DS1 interface, reports Loss of Frame Alignment (Sync Loss).
NTF ds1LocalSyncLossTrap1.3.6.1.4.1.164.3.1.6.4.0.9This trap indicates near end (Local) Loss of Frame Alignment failure (Sync Loss), of the user DS1 interface
NTF ds1AisSyncLossTrap1.3.6.1.4.1.164.3.1.6.4.0.10This trap indicates near end (Local) Loss of Frame Alignment (Sync Loss), caused by the reception of AIS at the user DS1 interface.
NTF ds1AisTrap1.3.6.1.4.1.164.3.1.6.4.0.11This trap indicates AIS being received at the user DS1 interface.
NTF ds1NetworkRemoteLoopTrap1.3.6.1.4.1.164.3.1.6.4.0.12This trap indicates that a remote loopback has been activated, on the local uplink interface.
NTF ds1RemoteLoopTrap1.3.6.1.4.1.164.3.1.6.4.0.13This trap indicates that a remote loopback has been activated, on the local user port.
NTF ds1LocalLoopTrap1.3.6.1.4.1.164.3.1.6.4.0.14This trap indicates that a local loopback has been activated on the user port.
NTF ds1ExcessiveFrameSlipTrap1.3.6.1.4.1.164.3.1.6.4.0.15This trap indicates that the number of Frame Slips detected at the user DS1 interface, during the last minute exceeds threshold. For LA-110, threshold value is 10. This usually indicates timing problems (incorrect selection of timing reference) on the user DS1.
NTF ds1ExcessiveCrc4ErrorTrap1.3.6.1.4.1.164.3.1.6.4.0.16This trap indicates that the error rate detected on the CRC-4 bits at the user DS1 interface, is high.
NTF ds1ExcessiveLocalMfAlarmTrap1.3.6.1.4.1.164.3.1.6.4.0.17This trap indicates that the number of local Loss of Multiframe Alignment events, detected at the user E1 interface during the last minute exceeds threshold. For LA-110, threshold value is 10.
NTF ds1ExcessiveRemoteMfAlarmTrap1.3.6.1.4.1.164.3.1.6.4.0.18This trap indicates that the number of Loss of multiframe alignment events reported by the remote unit connected to the user E1 interface during the last minute exceeds threshold. For LA-110, threshold value is 10.
NTF ds1ExcessiveRemoteSyncLossTrap1.3.6.1.4.1.164.3.1.6.4.0.19This trap indicates that the number of far end (remote) Loss of Synchronization alarms, reported by the user DS1 interface during the last minute, exceeds threshold. For LA-110, threshold value is 10.
NTF ds1ExcessiveLocalSyncLossTrap1.3.6.1.4.1.164.3.1.6.4.0.20This trap indicates that the number of Loss of local Synchronization alarms reported by the user DS1 interface during the last minute, exceeds threshold. For LA-110, threshold value is 10.
NTF ds1SignalLossTrap1.3.6.1.4.1.164.3.1.6.4.0.21This trap indicates Signal Loss. (possible reason - cable disconnection. etc.)
prtDs1PerfHistory1.3.6.1.4.1.164.3.1.6.4.1
dsx1XCurrentTable1.3.6.1.4.1.164.3.1.6.4.1.2not-accessibleA list of current statistics entries. This table contains additional objects for the current table.
dsx1XCurrentEntry1.3.6.1.4.1.164.3.1.6.4.1.2.1not-accessibleAn entry containing additional statistical counters applicable to a particular current table.
PER dsx1CurrentLOS1.3.6.1.4.1.164.3.1.6.4.1.2.1.1PerfCurrentCountread-onlyThe counter associated with the number of LOS seconds, encountered by a DS1 interface in the current 15 minute interval.
PER dsx1CurrentLOF1.3.6.1.4.1.164.3.1.6.4.1.2.1.2PerfCurrentCountread-onlyThe counter associated with the number of LOF seconds, encountered by a DS1 interface in the current 15 minute interval.
PER dsx1CurrentLOC1.3.6.1.4.1.164.3.1.6.4.1.2.1.3PerfCurrentCountread-onlyLoss Of Cell delineation. Counts number of cells the ATM UNI cells receiver lost cells delineation .
PER dsx1CurrentAIS1.3.6.1.4.1.164.3.1.6.4.1.2.1.4PerfCurrentCountread-onlyThe counter associated with the number of AIS seconds, encountered by a DS1 interface in the current 15 minute interval.
PER dsx1CurrentRAI1.3.6.1.4.1.164.3.1.6.4.1.2.1.5PerfCurrentCountread-onlyRemote Alarm Indication: Transmitted in the outgoing direction (toward the PABX) over FDL bits when the DS1 device detected an incoming Loss Of Frame. Received from the far end (PABX) over FDL when it detects a Loss of frame.
PER dsx1CurrentLOMF1.3.6.1.4.1.164.3.1.6.4.1.2.1.6PerfCurrentCountread-onlyLoss of Multi-Frame sequence in E1 time slot 16.
PER dsx1CurrentFEBE1.3.6.1.4.1.164.3.1.6.4.1.2.1.7PerfCurrentCountread-onlyFar End Block Errors, as reported in the first bit of frames 13 and 15, on multiframe E1 lines with CRC4, in the current 15 minute interval.
OCT dsx1CurrentStatus1.3.6.1.4.1.164.3.1.6.4.1.2.1.8OCTET STRINGread-onlyThe statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
PER dsx1CurrentBPV1.3.6.1.4.1.164.3.1.6.4.1.2.1.9PerfCurrentCountread-onlyThe counter associated with the number of BPVs (Bi-Polar Violations) encountered by a DS1 interface in the current 15 minute interval.
PER dsx1CurrentLOCRCMF1.3.6.1.4.1.164.3.1.6.4.1.2.1.10PerfCurrentCountread-onlyLoss of CRC4 Multi-Frame sequence in E1. encountered in the current 15 minute interval
PER dsx1CurrentLOFC1.3.6.1.4.1.164.3.1.6.4.1.2.1.11PerfCurrentCountread-onlyCounts the number of loss of frame events measured. encountered in the current 15 minute interval
PER dsx1CurrentCRCErrors1.3.6.1.4.1.164.3.1.6.4.1.2.1.12PerfCurrentCountread-onlyCounts the number of CRC error events, encountered in the current 15 minute interval.
dsx1XIntervalTable1.3.6.1.4.1.164.3.1.6.4.1.3not-accessibleA list of Interval entries. This table contains additional objects for the interval table.
dsx1XIntervalEntry1.3.6.1.4.1.164.3.1.6.4.1.3.1not-accessibleAn entry containing additional statistical counters applicable to a particular interval table.
NUM dsx1IntervalLOS1.3.6.1.4.1.164.3.1.6.4.1.3.1.1PerfIntervalCountread-onlyThe counter associated with the number of LOS seconds , encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
NUM dsx1IntervalLOF1.3.6.1.4.1.164.3.1.6.4.1.3.1.2PerfIntervalCountread-onlyThe counter associated with the number of OOF seconds, encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
NUM dsx1IntervalLOC1.3.6.1.4.1.164.3.1.6.4.1.3.1.3PerfIntervalCountread-onlyLoss Of Cell delineation. Counts number of cells the ATM UNI cells receiver lost cells delineation .
NUM dsx1IntervalAIS1.3.6.1.4.1.164.3.1.6.4.1.3.1.4PerfIntervalCountread-onlyThe counter associated with the number of AIS seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
NUM dsx1IntervalRAI1.3.6.1.4.1.164.3.1.6.4.1.3.1.5PerfIntervalCountread-onlyRemote Alarm Indication: Transmitted in the outgoing direction (toward the PABX) over FDL bits when the DS1 device detected an incoming Loss Of Frame. Received from the far end (PABX) over FDL when it detects a Loss of frame.
NUM dsx1IntervalLOMF1.3.6.1.4.1.164.3.1.6.4.1.3.1.6PerfIntervalCountread-onlyLoss of Multi-Frame sequence in E1 time slot 16.
NUM dsx1IntervalFEBE1.3.6.1.4.1.164.3.1.6.4.1.3.1.7PerfIntervalCountread-onlyFar End Block Errors, as reported in the first bit of frames 13 and 15, on multiframe E1 lines with CRC4, in one of the previous 96, individual, 15 minute intervals.
OCT dsx1IntervalStatus1.3.6.1.4.1.164.3.1.6.4.1.3.1.8OCTET STRINGread-onlyThe statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
NUM dsx1IntervalBPV1.3.6.1.4.1.164.3.1.6.4.1.3.1.9PerfIntervalCountread-onlyThe counter associated with the number of BPV (Bi-Polar Violations) encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
NUM dsx1IntervalLOCRCMF1.3.6.1.4.1.164.3.1.6.4.1.3.1.10PerfIntervalCountread-onlyLoss of CRC4 Multi-Frame sequence in E1.
NUM dsx1IntervalLOFC1.3.6.1.4.1.164.3.1.6.4.1.3.1.11PerfIntervalCountread-onlyCounts the number of loss of frame events measured in one of the previous 96, individual 15 minute, intervals.
dsx1XTotalTable1.3.6.1.4.1.164.3.1.6.4.1.4not-accessibleA list of Total statistics entries. This table contains additional objects for the Total table.
dsx1XTotalEntry1.3.6.1.4.1.164.3.1.6.4.1.4.1not-accessibleAn entry containing additional statistical counters applicable to a particular current table.
PER dsx1TotalLOS1.3.6.1.4.1.164.3.1.6.4.1.4.1.1PerfTotalCountread-onlyThe counter associated with the number of LOS (Loss of Signal) seconds encountered by a DS1 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
PER dsx1TotalBPV1.3.6.1.4.1.164.3.1.6.4.1.4.1.9PerfTotalCountread-onlyThe counter associated with the number of BPV (Bi-Polar Violations) encountered by a DS1 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
PER dsx1TotalLOFC1.3.6.1.4.1.164.3.1.6.4.1.4.1.11PerfTotalCountread-onlyThe counter associated with the number loss of frames encountered by a DS1 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx1DataStreamStatTable1.3.6.1.4.1.164.3.1.6.4.1.5not-accessibleThe DS1 Data Stream Statistics table.
dsx1DataStreamStatEntry1.3.6.1.4.1.164.3.1.6.4.1.5.1not-accessibleAn entry in the DS1 Data Stream Statistics table.
I32 dsx1DataStreamStatIfIndex1.3.6.1.4.1.164.3.1.6.4.1.5.1.1Integer32not-accessibleThe index of the DS1 interface. It may be ifIndex.
I32 dsx1DataStreamStatIndex1.3.6.1.4.1.164.3.1.6.4.1.5.1.2Integer32not-accessibleThe DS1 Data Stream Index. For Vmux - the following indices are used: 1 for Transparent 2-3 for SS71-SS72 (respectively) 4-7 for Data1-Data4 (respectively) 8 for HDLC Ph2 Compatible 9-16 for Sub-CH1-1...Sub-CH1-8 (respectively).
T/F dsx1DataStreamStatValid1.3.6.1.4.1.164.3.1.6.4.1.5.1.3TruthValueread-onlyIndicates whether this Data Stream is valid or not. When invalid - all counters are irrelevant.
C32 dsx1DataStreamStatInFrames1.3.6.1.4.1.164.3.1.6.4.1.5.1.4Counter32read-onlyThe counter associated with the number of received frames, encountered by the DS1 Data Stream.
C32 dsx1DataStreamStatInBytes1.3.6.1.4.1.164.3.1.6.4.1.5.1.5Counter32read-onlyThe counter associated with the number of received bytes, encountered by the DS1 Data Stream.
C32 dsx1DataStreamStatInDiscards1.3.6.1.4.1.164.3.1.6.4.1.5.1.6Counter32read-onlyThe counter associated with the number of Discarded incoming frames, encountered by the DS1 Data Stream.
C32 dsx1DataStreamStatInErrors1.3.6.1.4.1.164.3.1.6.4.1.5.1.7Counter32read-onlyThe counter associated with the number of received Errored frames, encountered by the DS1 Data Stream.
C32 dsx1DataStreamStatOutFrames1.3.6.1.4.1.164.3.1.6.4.1.5.1.8Counter32read-onlyThe counter associated with the number of transmitted frames, encountered by the DS1 Data Stream.
C32 dsx1DataStreamStatOutBytes1.3.6.1.4.1.164.3.1.6.4.1.5.1.9Counter32read-onlyThe counter associated with the number of transmitted bytes, encountered by the DS1 Data Stream.
C32 dsx1DataStreamStatOutDiscards1.3.6.1.4.1.164.3.1.6.4.1.5.1.10Counter32read-onlyThe counter associated with the number of Discarded outgoing frames, encountered by the DS1 Data Stream.
C32 dsx1DataStreamStatOutErrors1.3.6.1.4.1.164.3.1.6.4.1.5.1.11Counter32read-onlyThe counter associated with the number of errored transmitted frames, encountered by the DS1 Data Stream.
dsx1XConfigTable1.3.6.1.4.1.164.3.1.6.4.2not-accessibleAn extension to the DS1 Configuration table.
dsx1XConfigEntry1.3.6.1.4.1.164.3.1.6.4.2.1not-accessibleAn entry containing additional configuration parameters.
I32 dsx1IdleCode1.3.6.1.4.1.164.3.1.6.4.2.1.1Integer32read-writeByte pattern of the data received/transmitted in the E1T1 framer idle timeslots. Valid range: (0 - FF HEX).
INT dsx1LineMode1.3.6.1.4.1.164.3.1.6.4.2.1.2INTEGERread-writeT1 device operation mode. Valid for T1 only.
INT dsx1dBTxGain1.3.6.1.4.1.164.3.1.6.4.2.1.3INTEGERread-writeTransmit line Gain for T1 CSU line mode.
INT dsx1RxSensitivity1.3.6.1.4.1.164.3.1.6.4.2.1.4INTEGERread-writeLow Sensitivity is considered Short Haul while High Sensitivity is considered Long Haul. The actual values depend on the LIU. Examples: - E1: -12dB is considered Short Haul ; -43dB is considered Long Haul - T1: -12dB is considered Short Haul ; -36dB is considered Long Haul.
INT dsx1RestoreTime1.3.6.1.4.1.164.3.1.6.4.2.1.5INTEGERread-writeUsed to change the sync. algorithms to reduce the time required for the port to return to normal operation after a RED alarm. 'sec1' = Fast, 'sec10' = TR-6211, 'immediate' = CCITT
I32 dsx1TcFirstSignal1.3.6.1.4.1.164.3.1.6.4.2.1.6Integer32read-writeTrunk conditioning signal - value to be sent as a signal during the first 2.5 seconds after alarm detection. Range is 0x0..0xF. 0xFF is a NULL value. This variable is used also for Space Signaling Code (in this case 0xFF is not NULL).
I32 dsx1TcSignal1.3.6.1.4.1.164.3.1.6.4.2.1.7Integer32read-writeTrunk conditioning signal value after alarm detection. Range is 0x1..0xF for E1, and 0x0..0xF for T1. This variable is used also for Space Signaling Code (E1 and T1).
I32 dsx1TcPattern1.3.6.1.4.1.164.3.1.6.4.2.1.8Integer32read-writeTrunk conditioning data pattern to be sent upon a DS0 fail. Range is 0x0..0xFF. This variable used also for Out of Service Code.
INT dsx1Scramble1.3.6.1.4.1.164.3.1.6.4.2.1.9INTEGERread-writeScrambling is an operation that randomizes the bits of the payload of the ATM cell by a polynom. This operation helps with the error detection mechanism of the HEC. Not applicable for E1. active - will scramble/descramble the payload ATM cell notActive - will not scramble/descramble.
INT dsx1LineAdaptiveTimingMode1.3.6.1.4.1.164.3.1.6.4.2.1.10INTEGERread-writeEnables end to end clock synchronization. Default value - off.
INT dsx1TxClockSource1.3.6.1.4.1.164.3.1.6.4.2.1.11INTEGERread-writeThe source of Transmit Clock. 'loopTiming' indicates that the recovered receive clock is used as the transmit clock. 'localTiming' indicates that a local clock source is used or when an external clock is attached to the box containing the interface. 'throughTiming' indicates that recovered receive clock from another interface is used as the transmit clock. 'adaptive' indicates that the clock is recovered according to the received data flow rate. 'system' indicates that the system clock is used as the transmit clock.
INT dsx1AisEnable1.3.6.1.4.1.164.3.1.6.4.2.1.12INTEGERread-writeEnable/ disable AIS transmit when Ethernet cable (for TDMoIP) is out (disconnected).
OCT dsx1TsEchoCancel1.3.6.1.4.1.164.3.1.6.4.2.1.13OCTET STRINGread-writeThis parameter defines for each TS whether Echo-Cancellation is on. Each bit represents one TS as follow: First octet bit'0' = TS#1, bit'7' = TS#8, .. 2nd octet bit'0' = TS#9,.., 4th octet bit'7' = TS#32. Octets and bits order is from left to right: [31,30,..24] [23..16] [15..8] [7..0] MSB LSB MSB LSB MSB LSB MSB LSB For each bit values are: 0 - Echo-Cancellation off. 1 - Echo-Cancellation on.
INT dsx1EchoCancelerModule1.3.6.1.4.1.164.3.1.6.4.2.1.14INTEGERread-onlyThis parameter indicates whether echo-cancellation module exists for this line.
INT dsx1PortFunction1.3.6.1.4.1.164.3.1.6.4.2.1.15INTEGERread-writeThis object determines the ATM Mode over the physical port. uni - The port will function as an ATM UNI. ces - The port will function as a CES. ima - The port will function as an IMA-ATM. cesPsn - The port will function as a CES-PSN. abis - The port will function as an Abis.
INT dsx1PortMultiplier1.3.6.1.4.1.164.3.1.6.4.2.1.16INTEGERread-writeThis object determines the data rate of each TS (Kbps units). This parameter is applicable for T1 only.
INT dsx1LeasedLine1.3.6.1.4.1.164.3.1.6.4.2.1.17INTEGERread-writeThis parameter defines whether Line mode is regular (non Leased Line mode) or transparent (Leased Line mode).
INT dsx1CsuLoop1.3.6.1.4.1.164.3.1.6.4.2.1.18INTEGERread-writeThis parameter defines where the CSU loop will be done: local - locally (by IPmux) towards the TDM device transparent - transferred to Remote Device that will send it to its connected TDM device. remote - Remote Device will close the loop towards the Local Device.
I32 dsx1ClockSource1.3.6.1.4.1.164.3.1.6.4.2.1.19Integer32read-writeThis entry specifies the source from which the clock will be taken. Refer to device specification for source Index
INT dsx1OosSignal1.3.6.1.4.1.164.3.1.6.4.2.1.20INTEGERread-writeThis parameter defines the value to be sent as a signal after alarm detection: 'Space' = both A and B signaling bits are forced to '0' during out-of-service periods. 'Mark' = both A and B signaling bits are forced to '1' during out-of-service periods. 'spaceMark' = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. 'markSpace' = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. - '0'= 0 for T1, 1 for E1, or user defined value for Space - '1'= 1 for T1, 0 for E1, or user defined value for Mark.
I32 dsx1BundleNextIndex1.3.6.1.4.1.164.3.1.6.4.2.1.21Integer32read-onlyThis parameter indicates the Next free Bundle Index for this DS1 port.
INT dsx1CRC6CalcMode1.3.6.1.4.1.164.3.1.6.4.2.1.22INTEGERread-writeThis object determines the CRC6 Calculation mode. jtG704 =JT-G704 = the Japanese standard ituG704=ITU-G704 = the International standard This parameter is applicable for J1 only.
INT dsx1SendUponFail1.3.6.1.4.1.164.3.1.6.4.2.1.23INTEGERread-writeThis object determines which notification will be sent to the other side upon fail of another interface. In Ipmux14 the notification is sent upon failure of the Ethernet link.
ip2If1.3.6.1.4.1.164.3.1.6.7
ip2IfTable1.3.6.1.4.1.164.3.1.6.7.1not-accessibleChannels Configuration Table.
ip2IfEntry1.3.6.1.4.1.164.3.1.6.7.1.1not-accessibleApplication layer configuration per link
I32 ip2IfChannelIndex1.3.6.1.4.1.164.3.1.6.7.1.1.1Integer32read-onlyThe channel index, which is actualy the bundle ID.
ROW ip2IfRowStatus1.3.6.1.4.1.164.3.1.6.7.1.1.2RowStatusread-createThis parameter allows NMS to create/delete entries of this table.
INT ip2IfOperStatus1.3.6.1.4.1.164.3.1.6.7.1.1.3INTEGERread-onlyThe actual link status. remoteFail - No Rx. localFail - No Tx. unavailable - No echo replay or replay with invalid code or when connection is in Test state. valiodationFail - Connection is in not valid state. standby - offline (can be in pre-sync mode). tdmFail - oper status is down cause of failure in the tdm. hwMismatch - the bundle exists on a card that is not installed or has a different type than the programmed card.
INT ip2IfAdminStatus1.3.6.1.4.1.164.3.1.6.7.1.1.4INTEGERread-createThe desired state of the link.
IP ip2IfDestAddr1.3.6.1.4.1.164.3.1.6.7.1.1.5IpAddressread-createThe destination IP address.
IP ip2IfNextHop1.3.6.1.4.1.164.3.1.6.7.1.1.6IpAddressread-createThe next hop to which the frame should be sent. Default value - 0.0.0.0. Upon setting the default value the frame is sent to the default Gateway.
I32 ip2IfDestPort1.3.6.1.4.1.164.3.1.6.7.1.1.7Integer32read-createThe destination Bundle at the far-end device.
MAC ip2IfMacAddr1.3.6.1.4.1.164.3.1.6.7.1.1.8MacAddressread-createThe Destination MAC address of the next hop or destination station.
I32 ip2IfJitterBuffer1.3.6.1.4.1.164.3.1.6.7.1.1.9Integer32read-createThe maximum cell arrival jitter in 10 usec that the reassembly process will tolerate in the cell stream, without producing errors on the CBR service interface. For KM2100: KML.11 - The range that will be used is 3...300 msec in steps of 1 msec. For Vmux: The range that will be used is 20...100 msec in steps of 10 msec.
I32 ip2IfTos1.3.6.1.4.1.164.3.1.6.7.1.1.10Integer32read-createThe TOS (Type of Service) value: 0..255. In Vmux-2100/110 devices versions 3.1 and up, in Vmux-210 and in Vmux-4x0: LSB 8 bits - 00 00 00 XX will be used for Signaling packets TOS. Next 8 bits - 00 00 XX 00 will be used for Media packets TOS. Next 16 bits - will be 0. XX = Hex values: 0..FF For mixed packets, TOS of Media Packets will be used. Signaling packets are for example: Keep alive packets and ABCD signaling bits. Media packets are for example: voice, fax, HDLC, payload packets.
I32 ip2IfTDMBytesInFrame1.3.6.1.4.1.164.3.1.6.7.1.1.11Integer32read-createThe number of TDM bytes to be placed in a single IP frame payload. For ip2IfTDMoIpMode = cesOverPsn this parameter indicates the number of IP frames, calculated as: 1440/.
INT ip2IfVlanSupport1.3.6.1.4.1.164.3.1.6.7.1.1.12INTEGERread-createVLAN support (Tagging). no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame.
I32 ip2IfVlanIdentifier1.3.6.1.4.1.164.3.1.6.7.1.1.13Integer32read-createVLAN ID.
I32 ip2IfVlanFramePriority1.3.6.1.4.1.164.3.1.6.7.1.1.14Integer32read-createVLAN Frame priority.
INT ip2IfExitPort1.3.6.1.4.1.164.3.1.6.7.1.1.15INTEGERread-createThis object determines to which external port the traffic will be sent. auto - the device will decide automatically the exit port. If there is an option for Tx via more than one ETH card then use ext1 (1) and ext2(2) for ETH card #1 (ex. LAN1 or Ggabit-ETH1) and use card2Ext1(5) and card2Ext2(6) for card #2 (ex. LAN1 or Ggabit-ETH1). In Vmux-110/210 ext5 is used for ETH-NET, ext 6 is used for E1/T1 link and ext7 is used for Serial Link. In Vmux-2100 Main Board: ext 5 is used for ETH-NET, ext 6 is used for E1/T1 link A, prtE1T1B is used for E1/T1 link B and prtEthUser is used for ETH-User. prt17(10) - prt20(13) values were added in order to support Gmux2000 VMX Card.
OCT ip2IfVoiceOos1.3.6.1.4.1.164.3.1.6.7.1.1.16OCTET STRINGread-createVoice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
OCT ip2IfDataOos1.3.6.1.4.1.164.3.1.6.7.1.1.17OCTET STRINGread-createData Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
I32 ip2IfBundleUsage1.3.6.1.4.1.164.3.1.6.7.1.1.18Integer32read-onlyThe Bundle Resource usage in Kbps.
OCT ip2IfOAM1.3.6.1.4.1.164.3.1.6.7.1.1.19OCTET STRINGread-createThis parameter determine the OAM configuration. The LSB (Bit 0 the most right one) is used for OAM connectivity. Values: 0 = disable, 1= enable.
INT ip2IfTDMoIpMode1.3.6.1.4.1.164.3.1.6.7.1.1.20INTEGERread-createThe TDMoIP Mode configuration. Static- means TS can Tx any time. dynamicLES - means TS can Tx only when line is enabled according to LES protocol. dynamicCAS - means TS can Tx only when line is enabled according to CAS protocol. cesOverIp - use for information that this bundle is used for CES Over IP. voiceOverMpls - Voice over Multi Protocol Label Switching. hdlc - High Level Data Link. voIpComprHeader - indicates proprietary compressed IP header packets. voMplsComprHeader - indicates proprietary compressed MPLS header packets.
I32 ip2IfTimeElapsed1.3.6.1.4.1.164.3.1.6.7.1.1.21Integer32read-onlyThe number of seconds that have elapsed since the beginning of the current error-measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value.
I32 ip2IfValidIntervals1.3.6.1.4.1.164.3.1.6.7.1.1.22Integer32read-onlyThe number of previous intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online.
INT ip2IfFarEndType1.3.6.1.4.1.164.3.1.6.7.1.1.23INTEGERread-createThis object defines the type of the Far-End device. This data is important for signaling and DS0 format. For Vmux: e1 (2) value is used for a PBX in the Far End. fxs (5) is used for Phone. Other values are not used.
INT ip2IfRdnState1.3.6.1.4.1.164.3.1.6.7.1.1.24INTEGERread-onlyThis object defines the role this bundle plays in the redundancy scheme: none(2) - means this bundle is not part of redundancy pair. primary/ secondary - means this bundle is not part of redundancy pair, and that is the primary bundle or the secondary bunle.
IP ip2IfSourceAddr1.3.6.1.4.1.164.3.1.6.7.1.1.25IpAddressread-createSource IP Address of the bundle.
I32 ip2IfBandWidth1.3.6.1.4.1.164.3.1.6.7.1.1.26Integer32read-createDefines the Bandwidth of the bundle. For TDM bundles - it is the Number of Time Slots in The Bundle. - For T1 the value will be: 1..24 - For E1 the value will be: 1..31 - For T3 the value will be: 1..84 - For E3 the value will be: 1..63 This parameter is required for devices like Emux where the bandwidth of the bundles is unknown. The bundles that are received should be transmitted without any change in the bandwidth. It is the user's responsibility to enter the correct bandwidth. For Ethernet bundles - it is the bandwidth, measured in Kbps.
I32 ip2IfMeasuredSilence1.3.6.1.4.1.164.3.1.6.7.1.1.27Integer32read-onlyThis object shows the percentage of Silence that was measured by the device for the current bundle in the transmitted payload. Relevant values: 0..100, 255. Default value is 50. 0 means that there is no silence on the line. 100 means that there is only silence. In this case, there might be no traffic. 255 - value for not applicable or unknown.
INT ip2IfPayloadType1.3.6.1.4.1.164.3.1.6.7.1.1.28INTEGERread-createThis object defines the TDMoIP payload type.
INT ip2IfProtocolVersion1.3.6.1.4.1.164.3.1.6.7.1.1.29INTEGERread-createThis object defines the TDMoIP protocol Version.
IP ip2IfTdmBackUpNextHop1.3.6.1.4.1.164.3.1.6.7.1.1.30IpAddressread-createDefines the TDM bundle default router in case there was a switch from the Primary Link (for example an ETH port) to a TDM backup Link like E1, T1 or Serial Link. This parameter is relevant only when a Backup Link is configured. When a Backup Link is not configured the value will be: 0.0.0.0
INT ip2IfOosTxEnable1.3.6.1.4.1.164.3.1.6.7.1.1.31INTEGERread-createThis object defines whether OOS will be Transmitted. Note that for IPmux1000 the Lbit is always sent, but the OOS will be sent according to user selection in this parameter.
I32 ip2IfConnCheckPktFrequency1.3.6.1.4.1.164.3.1.6.7.1.1.32Integer32read-createTime in sec. between 2 Bundle Connectivity Check packets. Valid values: 0..60. 0 = Not Applicable.
I32 ip2IfConnPktTimeOutCycles1.3.6.1.4.1.164.3.1.6.7.1.1.33Integer32read-createNo. of cycles the agent will send Bundle Connectivity packets without receiving a response from the remote device before declaring that the bundle connection to the remote side is down - Time Out. Valid values: 0..5. 0 = Not Applicable.
INT ip2IfMfRelay1.3.6.1.4.1.164.3.1.6.7.1.1.34INTEGERread-createMulti Frequency Signaling Detection.
I32 ip2IfTxGain1.3.6.1.4.1.164.3.1.6.7.1.1.35Integer32read-createTransmit gain in dBm.
INT ip2IfSuperTandem1.3.6.1.4.1.164.3.1.6.7.1.1.36INTEGERread-createThe Super Tandem feature provides end to end compression over multiple hops, solving the double compression problem detected in Voice compressing systems. The Super Tandem allows transmission of compressed voice between a few Vmux 2100 hubs, and eliminates the need to decompress an recompress it over each voice card and PBX, thus improving voice quality and reducing delay.
I32 ip2IfSrcPort1.3.6.1.4.1.164.3.1.6.7.1.1.37Integer32read-createThe source Bundle at the local device, this parameter used for cases where there is no match between ip2IfChannelIndex and the Source Bundle ID.
INT ip2IfModemCalls1.3.6.1.4.1.164.3.1.6.7.1.1.38INTEGERread-createThis MIB object shows whether Modem Calls are enabled via the bundle. relay option (3) means that the bundle will send to the network only modulated data.
I32 ip2IfMinPulseWidth1.3.6.1.4.1.164.3.1.6.7.1.1.39Integer32read-createIndicates the minimum width in milliseconds of the MF (Multi Frequency) tone transmitted by the switch. Valid values: 45-300 msec. notApplicable=0.
I32 ip2IfMinPowerLevel1.3.6.1.4.1.164.3.1.6.7.1.1.40Integer32read-createIndicates the minimum power level in dBm of the MF (Multi Frequency) tone transmitted by the switch. Valid values: -1...-35 dBm.
INT ip2IfEchoCanceler1.3.6.1.4.1.164.3.1.6.7.1.1.41INTEGERread-createEcho canceler activation.
INT ip2IfCodingLaw1.3.6.1.4.1.164.3.1.6.7.1.1.42INTEGERread-createThis attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links.
INT ip2IfCustomToneDetect1.3.6.1.4.1.164.3.1.6.7.1.1.43INTEGERread-createCustom Tone Detection (COT) is a Control operation of a 2Khz tone detector. This tone is sent between PBX devices in order to check that the line status is OK. When the COT is enabled the device will not compress/decompress the tone. In this case, if the tone is initiated by the local PBX, the Device runs a 2Khz detector tone and once detected by the Remote Device, if the COT is enabled in the Remote Device, the Remote Device will generate a 2khz tone to the remote PBX.
I32 ip2IfCallerIdDelay1.3.6.1.4.1.164.3.1.6.7.1.1.44Integer32read-createTime in msec between CLID (Caller ID) signal detection on the line and CLID signal transmission. The CLID must be sent between ringing signals and the value of the delay is used for synchronizing the CLID transmission with the ringing signals transmission. Valid values: 0 - 3000 msec.
INT ip2IfConnectivityMode1.3.6.1.4.1.164.3.1.6.7.1.1.45INTEGERread-createThis MIB object shows whether to send Pings or OAM frames over the bundle.
INT ip2IfClockSourceEnable1.3.6.1.4.1.164.3.1.6.7.1.1.46INTEGERread-createThis MIB object defines whether this bundle can be a clock source.
INT ip2IfNetworkType1.3.6.1.4.1.164.3.1.6.7.1.1.47INTEGERread-createThis MIB object defines the network over which the Bundle PSN (Packet Switching Network)is transported. In Gmux2000: ipComprHeader indicates proprietary compressed IP header packets. mplsComprHeader indicates proprietary compressed MPLS header packets.
INT ip2IfMplsRxLabelEnable1.3.6.1.4.1.164.3.1.6.7.1.1.48INTEGERread-createThis MIB object defines whether there is user defined inner (Rx.) label for this Bundle.
I32 ip2IfMplsRxLabel1.3.6.1.4.1.164.3.1.6.7.1.1.49Integer32read-createThis MIB object defines the MPLS Rx. Label for this Bundle.
INT ip2IfMplsTxLabelEnable1.3.6.1.4.1.164.3.1.6.7.1.1.50INTEGERread-createThis MIB object defines whether there is user defined outer (Tx.) label for this Bundle.
I32 ip2IfMplsTxLabel1.3.6.1.4.1.164.3.1.6.7.1.1.51Integer32read-createThis MIB object defines the MPLS Tx. Label for this Bundle.
I32 ip2IfMplsTxExpBits1.3.6.1.4.1.164.3.1.6.7.1.1.52Integer32read-createThe MPLS Network priority (EXP bits) used for this bundle.
INT ip2IfMfcSpoofing1.3.6.1.4.1.164.3.1.6.7.1.1.53INTEGERread-createThis MIB object defines whether the MFC (Multi Frequency Compelled) protocol spoofing will exist in the bundle. When the MFC Spoofing is used, the Local and Remote PBXs will send MFC Signaling to each other. The Vmuxes between the PBXs will send proprietary signaling to each other. They will however create and send MFC tones to their local PBX. The PBXs will not know that the actual signaling was not sent from a PBX but from a Vmux.
I32 ip2IfToneAckInterval1.3.6.1.4.1.164.3.1.6.7.1.1.54Integer32read-createTime Interval in milli seconds from the time a Vmux sends tone/s to a local PBX until it receives an acknowledgement from this PBX. Valid values: 60...400 in steps of 20.
INT ip2IfNextHopType1.3.6.1.4.1.164.3.1.6.7.1.1.55INTEGERread-createThis MIB object defines the Bundle next Hop Address Type.
INT ip2IfNoiseLevelForVAD1.3.6.1.4.1.164.3.1.6.7.1.1.56INTEGERread-createThis object defines the Level of Noise on the line, the Voice Activation Detector (VAD) will have to handle.
INT ip2IfClockPreferences1.3.6.1.4.1.164.3.1.6.7.1.1.57INTEGERread-createThe Clock preferences: accurateness (2) = Accurate clock is more important than Constant Delay. constantDelay (3)= Constant Delay is more important than Accurate clock .
INT ip2IfConnectionMode1.3.6.1.4.1.164.3.1.6.7.1.1.58INTEGERread-createThe Connection Mode: tdmOIpCe (2) = TDMOiP (CE) = Circuit Emulation. tdmOIpCv (3)= TDMOiP (CV) = Compressed Voice.
INT ip2IfRingBack1.3.6.1.4.1.164.3.1.6.7.1.1.59INTEGERread-createEnables or disable Ring Back.
INT ip2IfReversePolarity1.3.6.1.4.1.164.3.1.6.7.1.1.60INTEGERread-createEnables or disable Reverse polarity synthesis.
INT ip2IfPulseMeter1.3.6.1.4.1.164.3.1.6.7.1.1.61INTEGERread-createEnables or disable Pulse metering synthesis.
INT ip2IfPulseMeterFreq1.3.6.1.4.1.164.3.1.6.7.1.1.62INTEGERread-createFrequency of synthesized pulse metering for this bundle.
I32 ip2IfPulseMeterPeriod1.3.6.1.4.1.164.3.1.6.7.1.1.63Integer32read-createDuration of synthesized pulse metering. current values are: 100-250.
INT ip2IfOnHookDetect1.3.6.1.4.1.164.3.1.6.7.1.1.64INTEGERread-createEnables or disable immediate reaction to On-Hook bits from network in Ringing.
INT ip2IfComfortNoiseGen1.3.6.1.4.1.164.3.1.6.7.1.1.65INTEGERread-createEnable or disable Comfort Noise Generation (CNG). When this parameter is enabled and no voice payload exists on the line for some time period during the call (moments of silence), the device will generate a soft background noise which assures the user that the connection is still alive (CNG). When this parameter is disabled and no voice payload exists on the line, absolute silence will be heard (Comfort Noise will not be generated).
I32 ip2IfExitChannel1.3.6.1.4.1.164.3.1.6.7.1.1.66Integer32read-createThe channelized bundle that the voice bundle exits through. In Gmux2000 it is the ifIndex of the Channelized Bundle (sub-channel) that the Voice Bundle exits through. The ifIndex contains the Slot+Prt+Channelized Bundle No.
I32 ip2IfMaxVBDModemCalls1.3.6.1.4.1.164.3.1.6.7.1.1.67Integer32read-createMaximum VBD modem calls for this bundle.
I32 ip2IfMaxRelayModemCalls1.3.6.1.4.1.164.3.1.6.7.1.1.68Integer32read-createMaximum Relay modem calls for this bundle.
INT ip2IfCustomToneFrequency1.3.6.1.4.1.164.3.1.6.7.1.1.69INTEGERread-createThis is the frequency of the Custom Tone that is sent between PBXs in order to check that the line status is OK. When the Custom Tone Detection is enabled the device will not compress/decompress this tone. The custom tone that is received from the local PBX will be sent to the remote PBX with the same frequency it was received. When the Custom Tone Frequency is f1780Plus2000Hz (4), the device will not compress/decompress any tone with frequencies of 1780Hz or 2000 Hz.
INT ip2IfVadMethod1.3.6.1.4.1.164.3.1.6.7.1.1.70INTEGERread-createVoice Activity Detection (VAD) method. proprietary (2) - non standard VAD based only on power measurement. It is very sensitive to background noise. internalITUT (3) - standard ITU-T VAD. It is a robust method.
I32 ip2IfRxGain1.3.6.1.4.1.164.3.1.6.7.1.1.71Integer32read-createReceive gain in dBm.
INT ip2IfCallerIDType1.3.6.1.4.1.164.3.1.6.7.1.1.72INTEGERread-createCaller ID Type used by the DSP for this bundle. Bellcore type is used by the American method. V.23 type is used by the European method.
INT ip2IfPeerAddrType1.3.6.1.4.1.164.3.1.6.7.1.1.73INTEGERread-createThis MIB object defines the peer Address Type.
INT ip2IfVbdRate1.3.6.1.4.1.164.3.1.6.7.1.1.74INTEGERread-createVoice Band Data (VBD) rate for this bundle.
INT ip2IfDtmfDetection1.3.6.1.4.1.164.3.1.6.7.1.1.75INTEGERread-createEnable/Disable DTMF (Dual Tone Multi Frequency) detectors for this bundle.
U32 ip2IfNlpCutoffLevel1.3.6.1.4.1.164.3.1.6.7.1.1.76Unsigned32read-createNon Linear Processor (NLP) Cutoff Level for this bundle. This parameter is used by the echo canceller. It is the maximum absolute linear PCM amplitude of the near-end signal that will cause the NLP module to be active and to mute low level residual echo & noisy surroundings.
U32 ip2IfDtdErlRatioCutoffQ31.3.6.1.4.1.164.3.1.6.7.1.1.77Unsigned32read-createThe DTD ERL cutoff level is used in order to determine whether the near-end is talking or not. This parameter is used by the echo canceller when echo exists and there is voice with low volume on the line. DTD means Double Talk Detection. ERL means Echo Return Loss. It is the power difference [dB] between the far-end signal to the echo returned. The cutoff level is calculated for the value entering Q.3. This value will be divided by 2^3=8 in order to get the linear ratio.
INT ip2IfCASRedundancy1.3.6.1.4.1.164.3.1.6.7.1.1.78INTEGERread-createEnable/Disable CAS signaling redundancy. This parameter is useful when there are problems with the network and applicable only for CAS signaling: E1-MF (G.732S) or E1-CRC-MF (G.732SCRC ). enable (3) - means that each packet containing CAS signaling will be triplicated into 3 packets. disable (2)- No redundancy will exist. Only 1 packet containing CAS will be transmitted.
INT ip2IfBundleSensitivity1.3.6.1.4.1.164.3.1.6.7.1.1.79INTEGERread-createDenotes if the bundle is sensitive to delay in the network, or is sensitive to data errors in the network. Voice bundles are sensitive to delay; Non-voice bundles are sensitive to data errors.
INT ip2IfOAMBundleIdent1.3.6.1.4.1.164.3.1.6.7.1.1.80INTEGERread-createDenotes if an OAM bundle is identified according to the Bundle Number (0x3fff), or according to the value of the first nibble in the VCCV control word sent in the frame. controlWord - applicable only when ip2IfProtocolVersion = v2(2). When ip2IfProtocolVersion = v1(1), only bundleNumber is applicable.
U32 ip2IfMaxTxQueue1.3.6.1.4.1.164.3.1.6.7.1.1.81Unsigned32read-createMax Tx Queue buffer size, measured in msec (milliseconds). Low buffer size may cause the buffer to overflow and discard packets in case of burst of packets on the network. High buffer size allows to store this burst and not lose packets.
U32 ip2IfMaxGprsTxQueue1.3.6.1.4.1.164.3.1.6.7.1.1.82Unsigned32read-createMax GPRS Tx Queue buffer size, measured in msec (milliseconds). Low buffer size may cause the buffer to overflow and discard packets in case of burst of packets on the network. High buffer size allows to store this burst and not lose packets.
INT ip2IfV23HD1.3.6.1.4.1.164.3.1.6.7.1.1.83INTEGERread-createThis parameter shows whether V.23 Half Duplex Modem Protocol is enabled on the bundle.
OCT ip2IfModemProtocolMode1.3.6.1.4.1.164.3.1.6.7.1.1.84OCTET STRINGread-createThis octet string contains the mode of each Modem Protocol used on the bundle. For each protocol one octet will be used. Octet #1 will be used for V.22 Protocol. Octet #2, #3, #4... are reserved for future protocols. Octet #1 values: 0 - Not Applicable 1 - VBD: Voice Band Data. 2 - Relay: Pulse Code Modulated (PCM) data is sent via the bundle. For V.22: This MIB object is relevant only when ip2IfModemCalls = relay (4).
U32 ip2IfCdisCngDetectionTime1.3.6.1.4.1.164.3.1.6.7.1.1.85Unsigned32read-createWhen working with CDIS (Call DIScrimination method) or CNG (Comfort Noise Generation): The time in msec that the device will detect 1100Hz & 2100Hz signals on the line before switching to modem or fax. For Vmux: the values will be in steps of 10 msec.
OCT ip2IfSuperTandemBitMask1.3.6.1.4.1.164.3.1.6.7.1.1.86OCTET STRINGread-createThis MIB object enables controlling the Time Slot/Channel rate. Valid values: 1 - FF HEX Each BIT represents 1/8 of the TS. Example: 7E (0111 1110) means that 6/8 of the TS (the center ones) are masked and data will be Tx/Rx only through them. This MIB object is relevant only when Super Tandem is enabled.
U32 ip2IfVbdSwitchbackTime1.3.6.1.4.1.164.3.1.6.7.1.1.87Unsigned32read-createTime in msec required for the DSP to switch back from VBD (Voice Band Data) to Voice. For Vmux: the values will be in steps of 30 msec.
I32 ip2IfCallerIdTxGain1.3.6.1.4.1.164.3.1.6.7.1.1.88Integer32read-createThe gain value in dBm units used for transmitting the Caller ID signal on the bundle.
I32 ip2IfCallerIdRxGain1.3.6.1.4.1.164.3.1.6.7.1.1.89Integer32read-createThe gain value in dBm units of the Caller ID signal received on the bundle.
INT ip2IfUdpMuxMethod1.3.6.1.4.1.164.3.1.6.7.1.1.90INTEGERread-createThis parameter determines according to which field the multiplexing is made: srcPort (2) - multiplexing according to the UDP Source Port (Dest=0x085e). This should be the default value, for backwards compatibility. destPort (3) - multiplexing according to the UDP Destination Port (standard multiplexing). The UDP Source and Destination ports' range is determined according to ip2IfUdpMuxMethod value: For srcPort (2) the range is 1-7000 For destPort (3) the range is 49152-65535.
INT ip2IfCallerIdDetection1.3.6.1.4.1.164.3.1.6.7.1.1.91INTEGERread-createEnable/Disable Caller ID Detection for this bundle.
INT ip2IfWap1.3.6.1.4.1.164.3.1.6.7.1.1.92INTEGERread-createEnable/Disable WAP (Wireless Application Protocol) for this bundle. WAP allows users to access the internet from wireless devices.
I32 ip2IfTDMFrameBytes1.3.6.1.4.1.164.3.1.6.7.2Integer32read-writeThe number of TDM bytes to be placed in a single IP frame payload.
I32 ip2IfTosValue1.3.6.1.4.1.164.3.1.6.7.3Integer32read-writeThe TOS value to write in the IP frame.
INT ip2IfVlanTagging1.3.6.1.4.1.164.3.1.6.7.4INTEGERread-writeVLAN support. no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame.
I32 ip2IfVlanID1.3.6.1.4.1.164.3.1.6.7.5Integer32read-writeVLAN ID.
I32 ip2IfVlanPriority1.3.6.1.4.1.164.3.1.6.7.6Integer32read-writeFrame priority.
ip2IfStatTable1.3.6.1.4.1.164.3.1.6.7.7not-accessibleChannels (Bundles) Statistics Table.
ip2IfStatEntry1.3.6.1.4.1.164.3.1.6.7.7.1not-accessibleIP Statistics per bundle
I32 ip2IfStatChIndex1.3.6.1.4.1.164.3.1.6.7.7.1.1Integer32read-onlyThe channel index, which is actualy the bundle ID.
I32 ip2IfStatSeqErrors1.3.6.1.4.1.164.3.1.6.7.7.1.2Integer32read-onlyNumber of events that the sequence number of an incoming Frame causes a transition from the 'sync' state to the 'out of sequence' state.
I32 ip2IfStatBufUnderflows1.3.6.1.4.1.164.3.1.6.7.7.1.3Integer32read-onlyNumber of events that the buffer underflows. This records the count of the number of events the Receive (Eth to TDM) buffer underflows. In the case of a continuous underflow caused by a loss of Frame flow, a single buffer underflow should be counted.
I32 ip2IfStatBufOverflows1.3.6.1.4.1.164.3.1.6.7.7.1.4Integer32read-onlyNumber of events that the buffer overflows. This records the count of the number of events the Receive (Eth to TDM) buffer overflows.
C32 ip2IfStatTxOnTimeInterval1.3.6.1.4.1.164.3.1.6.7.7.1.5Counter32read-onlyNumber of frames that were transmitted due to time interval elapse. The user can choose to Tx the Frame when it reaches the Max size or when the packetizing time interval elapses. The packetizing time interval is the interval in msec that it takes to build a Max. size frame.
C32 ip2IfStatTxOnMaxSize1.3.6.1.4.1.164.3.1.6.7.7.1.6Counter32read-onlyNumber of frames that were transmitted due to reaching max. frame size. The user can choose to Tx the Frame when it reaches the Max size or when the packetizing time interval elapses.
C32 ip2IfStatRxSignaling1.3.6.1.4.1.164.3.1.6.7.7.1.7Counter32read-onlyNumber of signaling frames that were received.
C32 ip2IfStatRxVoice1.3.6.1.4.1.164.3.1.6.7.7.1.8Counter32read-onlyNumber of voice frames that were received.
C32 ip2IfStatRxHdlc1.3.6.1.4.1.164.3.1.6.7.7.1.9Counter32read-onlyNumber of HDLC frames that were received.
C32 ip2IfStatTxSignaling1.3.6.1.4.1.164.3.1.6.7.7.1.10Counter32read-onlyNumber of signaling frames that were transmitted.
C32 ip2IfStatTxVoice1.3.6.1.4.1.164.3.1.6.7.7.1.11Counter32read-onlyNumber of voice frames that were transmitted.
C32 ip2IfStatTxHdlc1.3.6.1.4.1.164.3.1.6.7.7.1.12Counter32read-onlyNumber of HDLC frames that were transmitted.
C32 ip2IfStatRdnFlip1.3.6.1.4.1.164.3.1.6.7.7.1.13Counter32read-onlyNumber of redundancy flips occured. This parameter counts only flips from this bundle to the other bundle in the redundancy couple.
I32 ip2IfFarEndTdmStatus1.3.6.1.4.1.164.3.1.6.7.7.1.14Integer32read-onlyThis variable indicates the Status of the Far-End TDM Line. It contains failure state information. The variable is a bit map represented as a sum, therefore, it can represent multiple failures simultaneously. The farEndTdmNoDefect must be set if and only if no other flag is set. The various bit positions are: 1 farEndTdmNoDefect 2 farEndTdmAIS Alarm Indication Signal 4 farEndTdmRDI Remote Defect Indication
C32 ip2IfStatPsnTxFrames1.3.6.1.4.1.164.3.1.6.7.7.1.15Counter32read-onlyNumber of frames that were transmitted to PSN.
C32 ip2IfStatPsnRxFrames1.3.6.1.4.1.164.3.1.6.7.7.1.16Counter32read-onlyNumber of frames that were recieved from PSN.
U32 ip2IfStatMinJittBufLevel1.3.6.1.4.1.164.3.1.6.7.7.1.17Unsigned32read-onlyThe Minimum jitter buffer level (in msec).
U32 ip2IfStatMaxJittBufLevel1.3.6.1.4.1.164.3.1.6.7.7.1.18Unsigned32read-onlyThe Maximum jitter buffer level (in msec).
U32 ip2IfStatRecommendedJittBufSize1.3.6.1.4.1.164.3.1.6.7.7.1.19Unsigned32read-onlyThe Recommended jitter buffer Size (in msec). 0= not applicable.
C32 ip2IfStatPsnSeqErrors1.3.6.1.4.1.164.3.1.6.7.7.1.20Counter32read-onlyNumber of times that the sequence number of an incoming Frame indicates Loss of Frame or Out of order occured in PSN.
C32 ip2IfStatPsnReorderFrames1.3.6.1.4.1.164.3.1.6.7.7.1.21Counter32read-onlyNumber of times that Frames had been reordered in PSN.
U32 ip2IfStatMinRoundTripDelay1.3.6.1.4.1.164.3.1.6.7.7.1.22Unsigned32read-onlyThe minimum Round Trip delay (in msec). 0= not applicable.
U32 ip2IfStatMaxRoundTripDelay1.3.6.1.4.1.164.3.1.6.7.7.1.23Unsigned32read-onlyThe maximum Round Trip delay (in msec). 0= not applicable.
U32 ip2IfStatAvrRoundTripDelay1.3.6.1.4.1.164.3.1.6.7.7.1.24Unsigned32read-onlyThe avarage Round Trip delay (in msec). 0= not applicable.
C32 ip2IfStatFrameTrackDupDrop1.3.6.1.4.1.164.3.1.6.7.7.1.25Counter32read-onlyThe number of packets dropped due to being duplicated. (duplicated packet means a packet that has the same sequential number as a packet being received previously).
C32 ip2IfStatFrameTrackMissing1.3.6.1.4.1.164.3.1.6.7.7.1.26Counter32read-onlyThe number of packets that are missing. (Missing packet means an expected packet- according to the current sequential number - that was not received).
I32 ip2IfStatFrameTrackLongSerMiss1.3.6.1.4.1.164.3.1.6.7.7.1.27Integer32read-onlyThe longest series of consecutive missing sequential numbers. Missing sequential numbers represent missing packets that was expected to be received successively.
I32 ip2IfStatTxMeasuredSilence1.3.6.1.4.1.164.3.1.6.7.7.1.28Integer32read-onlyThis object shows the percentage of Silence that was measured by the device for the current bundle in the transmitted payload. Relevant values: 0..100, 255. Default value is 50. 0 means that there is no silence on the line. 100 means that there is only silence. In this case, there might be no traffic. 255 - value for not applicable or unknown.
I32 ip2IfStatRxMeasuredSilence1.3.6.1.4.1.164.3.1.6.7.7.1.29Integer32read-onlyThis object shows the percentage of Silence that was measured by the device for the current bundle in the received payload. Relevant values: 0..100, 255. Default value is 50. 0 means that there is no silence on the line. 100 means that there is only silence. In this case, there might be no traffic. 255 - value for not applicable or unknown.
C32 ip2IfStatHdlcCrcErr1.3.6.1.4.1.164.3.1.6.7.7.1.30Counter32read-onlyThis counter indicates the number of received HDLC frames with CRC errors.
C32 ip2IfStatHdlcAlignErr1.3.6.1.4.1.164.3.1.6.7.7.1.31Counter32read-onlyThis counter indicates the number of received HDLC frames with alignment errors.
C32 ip2IfStatHdlcOversize1.3.6.1.4.1.164.3.1.6.7.7.1.32Counter32read-onlyThis counter indicates the number of received HDLC frames longer than 1470.
C32 ip2IfStatHdlcUndersize1.3.6.1.4.1.164.3.1.6.7.7.1.33Counter32read-onlyThis counter indicates the number of received HDLC frames shorter than 4.
C32 ip2IfStatHdlcAbort1.3.6.1.4.1.164.3.1.6.7.7.1.34Counter32read-onlyThis counter indicates the number of received HDLC frames with abort indication.
C32 ip2IfStatRxCorrectFrames1.3.6.1.4.1.164.3.1.6.7.7.1.35Counter32read-onlyNumber of received correct frames.
C32 ip2IfStatHdlcErroredFrames1.3.6.1.4.1.164.3.1.6.7.7.1.36Counter32read-onlyNumber of received errored HDLC frames.
I32 ip2IfRateLimit1.3.6.1.4.1.164.3.1.6.7.8Integer32read-writeThe maximum rate permitted to transfer via the network portin Mbps.
ip2IfPortTable1.3.6.1.4.1.164.3.1.6.7.9not-accessiblePort Table.
ip2IfPortEntry1.3.6.1.4.1.164.3.1.6.7.9.1not-accessibleApplication layer configuration per Port
I32 ip2IfPortIndex1.3.6.1.4.1.164.3.1.6.7.9.1.1Integer32read-onlyThe Port index, which is actualy the ifIndex.
I32 ip2IfPortUsage1.3.6.1.4.1.164.3.1.6.7.9.1.2Integer32read-onlyThis parameter indicates the usage of the port (percents).
INT ip2IfPortMask1.3.6.1.4.1.164.3.1.6.7.9.1.3INTEGERread-writeThis parameter defines whether Agent will mask port's alarms and statistics or not.
I32 ip2IfPortTotalThroughput1.3.6.1.4.1.164.3.1.6.7.9.1.4Integer32read-onlyThis parameter indicates the total Throughput of the port in bps.
ip2IfCurrentStatTable1.3.6.1.4.1.164.3.1.6.7.10not-accessibleChannels (Bundles) Current Statistics Table.
ip2IfCurrentStatEntry1.3.6.1.4.1.164.3.1.6.7.10.1not-accessibleIP Current Statistics per bundle
C32 ip2IfCurrentStatSeqErrors1.3.6.1.4.1.164.3.1.6.7.10.1.1Counter32read-onlyNumber of seconds that the sequence number of an incoming Frame causes a transition from the 'sync' state to the 'out of sequence' state in the current interval.
C32 ip2IfCurrentStatBufUnderflows1.3.6.1.4.1.164.3.1.6.7.10.1.2Counter32read-onlyNumber of seconds that the buffer underflows in the current interval. This records the count of the number of seconds the Receive (Eth to TDM) buffer underflows in the current interval. In the case of a continuous underflow caused by a loss of Frame flow, a single buffer underflow should be counted.
C32 ip2IfCurrentStatBufOverflows1.3.6.1.4.1.164.3.1.6.7.10.1.3Counter32read-onlyNumber of seconds that the buffer overflows in the current interval. This records the count of the number of seonds the Receive (Eth to TDM) buffer overflows in the current interval.
I32 ip2IfCurrentStatMaxDelayVar1.3.6.1.4.1.164.3.1.6.7.10.1.4Integer32read-onlyThe maximum deviation from the center of the buffer (in msec) for the current interval.
U32 ip2IfCurrentStatMinJittBufLevel1.3.6.1.4.1.164.3.1.6.7.10.1.5Unsigned32read-onlyThe Minimum jitter buffer level (in msec) for the current interval.
U32 ip2IfCurrentStatMaxJittBufLevel1.3.6.1.4.1.164.3.1.6.7.10.1.6Unsigned32read-onlyThe Maximum jitter buffer level (in msec) for the current interval.
C32 ip2IfCurrentStatTxErrFrameSec1.3.6.1.4.1.164.3.1.6.7.10.1.7Counter32read-onlyThe number of seconds in which errored frames were transmitted during the current interval. The error may be one of the following: CRC error, Alignment error, Oversized frame, Undersized frame, Aborted frame.
ip2IfIntervalStatTable1.3.6.1.4.1.164.3.1.6.7.11not-accessibleChannels (Bundles) Interval Statistics Table.
ip2IfIntervalStatEntry1.3.6.1.4.1.164.3.1.6.7.11.1not-accessibleIP Interval Statistics per bundle
I32 ip2IfIntervalStatIndex1.3.6.1.4.1.164.3.1.6.7.11.1.1Integer32read-onlyThe Interval index, which is actualy the Interval number.
C32 ip2IfIntervalStatSeqErrors1.3.6.1.4.1.164.3.1.6.7.11.1.2Counter32read-onlyNumber of seconds that the sequence number of an incoming Frame causes a transition from the 'sync' state to the 'out of sequence' state in the selected interval.
C32 ip2IfIntervalStatBufUnderflows1.3.6.1.4.1.164.3.1.6.7.11.1.3Counter32read-onlyNumber of seconds that the buffer underflows in the selected interval. This records the count of the number of seconds the Receive (Eth to TDM) buffer underflows in the selected interval. In the case of a continuous underflow caused by a loss of Frame flow, a single buffer underflow should be counted.
C32 ip2IfIntervalStatBufOverflows1.3.6.1.4.1.164.3.1.6.7.11.1.4Counter32read-onlyNumber of seconds that the buffer overflows in the selected interval. This records the count of the number of seconds the Receive (Eth to TDM) buffer overflows in the selected interval.
I32 ip2IfIntervalStatMaxDelayVar1.3.6.1.4.1.164.3.1.6.7.11.1.5Integer32read-onlyThe maximum size of the buffer (in 10's of usec) in the selected interval.
U32 ip2IfIntervalStatMinJittBufLevel1.3.6.1.4.1.164.3.1.6.7.11.1.6Unsigned32read-onlyThe Minimum jitter buffer level (in msec) for the selected interval.
U32 ip2IfIntervalStatMaxJittBufLevel1.3.6.1.4.1.164.3.1.6.7.11.1.7Unsigned32read-onlyThe Maximum jitter buffer level (in msec) for the selected interval.
C32 ip2IfIntervalStatTxErrFrameSec1.3.6.1.4.1.164.3.1.6.7.11.1.8Counter32read-onlyThe number of seconds in which errored frames were transmitted during the selected interval. The error may be one of the following: CRC error, Alignment error, Oversized frame, Undersized frame, Aborted frame.
INT ip2IfLogEvents1.3.6.1.4.1.164.3.1.6.7.12INTEGERread-writeThis parameter defines whether all Jitter Buffer and Sequence Number events will enter to Log File, or enter those events to Log file in one minute steps.
INT ip2IfEthSwitchMode1.3.6.1.4.1.164.3.1.6.7.13INTEGERread-writeThis parameter defines whether Eth Switch is in VLAN Tagged mode.
broadbandIf1.3.6.1.4.1.164.3.1.6.8
bdbandConfig1.3.6.1.4.1.164.3.1.6.8.1
prtBdbandIndTable1.3.6.1.4.1.164.3.1.6.8.1.1not-accessibleThe Indication Signal table.
prtBdbandIndEntry1.3.6.1.4.1.164.3.1.6.8.1.1.1not-accessibleAn entry in the Indication Signal table.
I32 prtBdbandCnfgIdx1.3.6.1.4.1.164.3.1.6.8.1.1.1.1Integer32read-onlyThis object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1.
I32 prtBdbandIdx1.3.6.1.4.1.164.3.1.6.8.1.1.1.2Integer32read-onlyThis object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex.
INT prtBdbandIndSig1.3.6.1.4.1.164.3.1.6.8.1.1.1.3INTEGERread-onlyThis object indicates a unique Indication Signal. ais(1) = AIS = Alarm Indication Signal. rdi(2) = RDI = Remote Defect Indication.
INT prtBdbandIndEvent1.3.6.1.4.1.164.3.1.6.8.1.1.1.4INTEGERread-onlyThis object indicates a unique Event that can cause the Indication Signal. slm(2) = SLM = Signal Label Mismatch eed(4) = EED = Excessive Error Defect pathTrace(5) = the end-to-end source/destination of information is wrong. lom(6) = LOM = Loss of Multiframe. lop(7) = LOP = Loss of Pointer. slu(8) = SLU = Signal Label Unequipped.
INT prtBdbandIndSigEnable1.3.6.1.4.1.164.3.1.6.8.1.1.1.5INTEGERread-createThis object allows user to define if the event specified by prtBdbandIndEvent will cause creation of the Indication Signal specified by prtBdbandIndSig or not. disable - will not enable causing the signal enable - will enable causing the signal.
ROW prtBdbandRowStatus1.3.6.1.4.1.164.3.1.6.8.1.1.1.6RowStatusread-createCreation/Deletion of rows in the table.
prtPhyConfigTable1.3.6.1.4.1.164.3.1.6.8.1.2not-accessibleThe Phy Config table. Used now for Phy25.6 Mbps.
prtPhyConfigEntry1.3.6.1.4.1.164.3.1.6.8.1.2.1not-accessibleAn entry in the Phy Config table.
I32 prtPhyTimeElapsed1.3.6.1.4.1.164.3.1.6.8.1.2.1.1Integer32read-onlyThe number of seconds that have elapsed since the beginning of the current error-measurement period.
I32 prtPhyValidIntervals1.3.6.1.4.1.164.3.1.6.8.1.2.1.2Integer32read-onlyThe number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute since the interface has been online.
prtPhyPerfHistory1.3.6.1.4.1.164.3.1.6.8.2
prtPhyCurrentTable1.3.6.1.4.1.164.3.1.6.8.2.1not-accessibleThe 25.6 Mbps Section/Line Current table.
prtPhyCurrentEntry1.3.6.1.4.1.164.3.1.6.8.2.1.1not-accessibleAn entry in the 25.6 Mbps Line Current table. ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps.
G32 prtPhyCurrentLOS1.3.6.1.4.1.164.3.1.6.8.2.1.1.1Gauge32read-onlyThe counter associated with the number of Loss Of Sync seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
G32 prtPhyCurrentLSV1.3.6.1.4.1.164.3.1.6.8.2.1.1.2Gauge32read-onlyThe counter associated with the number of Line symbol violation seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
G32 prtPhyCurrentUAS1.3.6.1.4.1.164.3.1.6.8.2.1.1.3Gauge32read-onlyThe counter associated with the number of UAS encountered by a 25.6 Mbps interface in the current 15 minute interval.
G32 prtPhyCurrentSES1.3.6.1.4.1.164.3.1.6.8.2.1.1.4Gauge32read-onlyThe counter associated with the number of SES encountered by a 25.6 Mbps interface in the current 15 minute interval.
G32 prtPhyCurrentES1.3.6.1.4.1.164.3.1.6.8.2.1.1.5Gauge32read-onlyThe number of Errored Seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
OCT prtPhyCurrentStatus1.3.6.1.4.1.164.3.1.6.8.2.1.1.6OCTET STRINGread-onlyThe statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out.
G32 prtPhyCurrentLOF1.3.6.1.4.1.164.3.1.6.8.2.1.1.7Gauge32read-onlyThe number of Loss of Frames, encountered by an interface in the current 15 minute interval.
prtPhyIntervalTable1.3.6.1.4.1.164.3.1.6.8.2.2not-accessibleThe Line Interval table.
prtPhyIntervalEntry1.3.6.1.4.1.164.3.1.6.8.2.2.1not-accessibleAn entry in the 25.6 Mbps Line Interval table. ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps.
I32 prtPhyIntervalNumber1.3.6.1.4.1.164.3.1.6.8.2.2.1.1Integer32read-onlyA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
G32 prtPhyIntervalLOS1.3.6.1.4.1.164.3.1.6.8.2.2.1.2Gauge32read-onlyThe counter associated with the number of Loss Of Sync seconds , encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
G32 prtPhyIntervalLSV1.3.6.1.4.1.164.3.1.6.8.2.2.1.3Gauge32read-onlyThe counter associated with the number of line symbol violation seconds , encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
G32 prtPhyIntervalUAS1.3.6.1.4.1.164.3.1.6.8.2.2.1.4Gauge32read-onlyThe counter associated with the number of UAS encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
G32 prtPhyIntervalSES1.3.6.1.4.1.164.3.1.6.8.2.2.1.5Gauge32read-onlyThe counter associated with the number of SES encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
G32 prtPhyIntervalES1.3.6.1.4.1.164.3.1.6.8.2.2.1.6Gauge32read-onlyThe number of Errored Seconds, encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
OCT prtPhyIntervalStatus1.3.6.1.4.1.164.3.1.6.8.2.2.1.7OCTET STRINGread-onlyThe statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out.
G32 prtPhyIntervalLOF1.3.6.1.4.1.164.3.1.6.8.2.2.1.8Gauge32read-onlyThe number of Loss of Frames, encountered by an interface in one of the previous 96, individual 15 minute intervals.
muxHub1.3.6.1.4.1.164.3.2
muxHubEvents1.3.6.1.4.1.164.3.2.0The events for .
NTF alarmsTrap1.3.6.1.4.1.164.3.2.0.1This trap is sent whenever alarm occurs in the agent.
NTF sanityTrap1.3.6.1.4.1.164.3.2.0.2This trap is sent after a data base update. It returns the sanity result status and the configuration no. checked. If the result is of Flip DB Sanity Check, the configuration no. sent will be 0. If the result is of Variant Sanity Check, the configuration no. sent will be 100.
NTF cnfgFlipTrap1.3.6.1.4.1.164.3.2.0.3This trap is sent upon change of the active Configuration DB. Attached, is the new active Configuration no.
NTF flipDbChangeTrap1.3.6.1.4.1.164.3.2.0.4This trap is sent upon change of the active Flip tables (Flip DB).
NTF statusChangedTrap1.3.6.1.4.1.164.3.2.0.5This trap is sent upon any change of the LEDs status.
agnMux1.3.6.1.4.1.164.3.2.1
mdlMux1.3.6.1.4.1.164.3.2.2
cnfgMdlMux1.3.6.1.4.1.164.3.2.2.1
mdlPbxFramerCnfg1.3.6.1.4.1.164.3.2.2.1.1
mdlPbxFramerCnfgTable1.3.6.1.4.1.164.3.2.2.1.1.1not-accessibleThis table contains parameters relevant to a module belonging to a digital voice system, except mdlPbxFraEnhEcho which is relevant also for analog cards.
mdlPbxFramerCnfgEntry1.3.6.1.4.1.164.3.2.2.1.1.1.1not-accessibleAn entry in table.
I32 mdlPbxFraCnfgIdx1.3.6.1.4.1.164.3.2.2.1.1.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT mdlPbxFraSltIdx1.3.6.1.4.1.164.3.2.2.1.1.1.1.2INTEGERread-onlyThe slot relevant to this module.
INT mdlPbxFraEnhEcho1.3.6.1.4.1.164.3.2.2.1.1.1.1.3INTEGERread-writeRefers to external ports of an analogue module and to the internal ports of the other mvc4 types of modules. ms16(3) means that the four voice ports have enhanced echo of 16ms. ms32(4) means that the two first ports have enhanced echo of 32 ms while the last two ports have no enhanced echo.
INT mdlPbxFraTSGroupAss1.3.6.1.4.1.164.3.2.2.1.1.1.1.4INTEGERread-writeIn case of T1 modules: group1=(1,2,3,4), ...., group6=(21,22,23,24) while in case of E1 modules: - If prtExPh1MlLineType=g732sE1 or g732sE1CRC: group1=(1,2,3,4),..,group4=(13,14,15,17), group5=(18,19,20,21),...,group7=(26,27,28,29) group8=(30,31). - If prtExPh1MlLineType=g732nE1 or g732nE1CRC: group1=(1,2,3,4),..,group4=(13,14,15,16), group5=(17,18,19,20),...,group7=(25,26,27,28) group8=(29,30,31).
INT mdlPbxFraSignalMode1.3.6.1.4.1.164.3.2.2.1.1.1.1.5INTEGERread-writeRefers to the signaling mode of the Framer module. tieTrunk(2), tieInvert(3), casTrans(4) are standard coding of the signaling protocol. casTrans(4) is Channel Associated Signaling (the signaling is within the channels time slot). ccsTrans(6) is Transparent Common Channel Signaling (the signaling is not within the channels time slot - a TS for signaling is used). userDefined(5) allows the user to define the signaling protocol he wants. In this case, the next two MIB fields are relevant.
OCT mdlPbxFraSignalVector1.3.6.1.4.1.164.3.2.2.1.1.1.1.6OCTET STRINGread-writeIn the case of mdlPbxFraSignalMode = userDefined(5), this field defines the A,B,C Bits. D bit is supplied for future versions. Bit 1 = Bit A ON Hook - Local Bit 2 = Bit B ON Hook - Local Bit 3 = Bit C ON Hook - Local Bit 4 = Bit D ON Hook - Local Bit 5 = Bit A OFF Hook - Local Bit 6 = Bit B OFF Hook - Local Bit 7 = Bit C OFF Hook - Local Bit 8 = Bit D OFF Hook - Local Bit 9 = Bit A ON Hook - Remote Bit 10 = Bit B ON Hook - Remote Bit 11 = Bit C ON Hook - Remote Bit 12 = Bit D ON Hook - Remote Bit 13 = Bit A OFF Hook - Remote Bit 14 = Bit B OFF Hook - Remote Bit 15 = Bit C OFF Hook - Remote Bit 16 = Bit D OFF Hook - Remote In conjunction with the Mask, mdlPbxFraSignalMask, it is possible to compute the signal mode.
OCT mdlPbxFraSignalMask1.3.6.1.4.1.164.3.2.2.1.1.1.1.7OCTET STRINGread-writeIn the case of mdlPbxFraSignalMode = userDefined(5), this field defines the 'don't care' A,B,C Bits. D bit is supplied for future versions. Bit 1 = Bit A ON Hook - Local Bit 2 = Bit B ON Hook - Local Bit 3 = Bit C ON Hook - Local Bit 4 = Bit D ON Hook - Local Bit 5 = Bit A OFF Hook - Local Bit 6 = Bit B OFF Hook - Local Bit 7 = Bit C OFF Hook - Local Bit 8 = Bit D OFF Hook - Local Bit 9 = Bit A ON Hook - Remote Bit 10 = Bit B ON Hook - Remote Bit 11 = Bit C ON Hook - Remote Bit 12 = Bit D ON Hook - Remote Bit 13 = Bit A OFF Hook - Remote Bit 14 = Bit B OFF Hook - Remote Bit 15 = Bit C OFF Hook - Remote Bit 16 = Bit D OFF Hook - Remote.
INT mdlPbxFraFramerSlot1.3.6.1.4.1.164.3.2.2.1.1.1.1.8INTEGERread-writeSlot where is sitting the Framer.
INT mdlPbxFraSignaling1.3.6.1.4.1.164.3.2.2.1.1.1.1.9INTEGERread-writeSignaling - describes the way the signaling ABCD bits pass from the local extension to the remote extension and vice-versa. endToEnd = the signaling ABCD bits pass without change from local to remote extension. localTermination = the signaling ABCD bits received from the local extension are translated to different ON Hook/OFF Hook bit values and then passed to remote extension. This is relevant when the Local and Remote ON Hook/OFF Hook values are different.
I32 mdlPbxFraTransSigTs1.3.6.1.4.1.164.3.2.2.1.1.1.1.10Integer32read-writeThis is the Time Slot that is used for Transparent CCS signaling. The values of this TS are 1-24 for T1 & 1-31 for E1. The default for E1 is 16 & for T1 it is 24. If no signaling is used then the TS should be 255 (None).
mdlProtIpTable1.3.6.1.4.1.164.3.2.2.1.2not-accessibleThis table contains Protected IP Addresses for ML-IP cards when working in IP Ring Mode.
mdlProtIpEntry1.3.6.1.4.1.164.3.2.2.1.2.1not-accessibleAn entry in table.
I32 mdlProtIpCnfgIdx1.3.6.1.4.1.164.3.2.2.1.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg being accessed. Idx 255 relates to the TmpCnfg. For Agents having several configuration, Write operation is allowed only to the Temporary Configuration.
INT mdlProtIpSlotIdx1.3.6.1.4.1.164.3.2.2.1.2.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the module is inserted. In the 2104 Unit the entries io6(10)..io16) are not valid.
IP mdlProtIpAddress1.3.6.1.4.1.164.3.2.2.1.2.1.3IpAddressread-onlyA Protected IP address.
ROW mdlProtIpRowStatus1.3.6.1.4.1.164.3.2.2.1.2.1.4RowStatusread-createThis parameter allows creating/deleting entries of this table.
statMdlMux1.3.6.1.4.1.164.3.2.2.2
mdlStatTable1.3.6.1.4.1.164.3.2.2.2.1not-accessibleA table.
mdlStatEntry1.3.6.1.4.1.164.3.2.2.2.1.1not-accessibleAn entry in table.
INT mdlStatSltIdx1.3.6.1.4.1.164.3.2.2.2.1.1.1INTEGERread-onlyA unique number to identify a slot position in the mux. In the 2104 Unit the entries psB(2),clB(4),io6(10)..io12(16) are not valid.
IP mdlStatHostIP1.3.6.1.4.1.164.3.2.2.2.1.1.2IpAddressread-onlyThe host interface IP address when DHCP Client=Yes. This object is relevant only when DHCP Client=Yes
IP mdlStatHostMask1.3.6.1.4.1.164.3.2.2.2.1.1.3IpAddressread-onlyThe host interface subnet mask when DHCP Client=Yes. This object is relevant only when DHCP Client=Yes
IP mdlStatDefaultGateway1.3.6.1.4.1.164.3.2.2.2.1.1.4IpAddressread-onlyDefault Gateway's IP Address when DHCP Client=Yes. This object is relevant only when DHCP Client=Yes
prtMux1.3.6.1.4.1.164.3.2.3
statPrtMux1.3.6.1.4.1.164.3.2.3.1
prtSExHsfStatTable1.3.6.1.4.1.164.3.2.3.1.6not-accessibleA table.
prtSExHsfStatEntry1.3.6.1.4.1.164.3.2.3.1.6.1not-accessibleAn entry in table.
INT prtSExHsfSltIdx1.3.6.1.4.1.164.3.2.3.1.6.1.1INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
INT prtSExHsfPrtIdx1.3.6.1.4.1.164.3.2.3.1.6.1.2INTEGERread-onlyThis attribute indicates a unique port number.
INT prtSExHsfInterfaceTyp1.3.6.1.4.1.164.3.2.3.1.6.1.3INTEGERread-onlyThis attribute indicates a unique interface type of a selected port.
INT prtSExHsfRts1.3.6.1.4.1.164.3.2.3.1.6.1.4INTEGERread-onlyThis attribute indicates a unique RTS control signal state.
prtIsdnStatusTable1.3.6.1.4.1.164.3.2.3.1.16not-accessibleThis table contains ISDN Statistics parameters that do not appear in the standard MIBs or for agents that don't support the standard Index of Call Set Up Time.
prtIsdnStatusEntry1.3.6.1.4.1.164.3.2.3.1.16.1not-accessibleEntries for ISDN Statistics parameters that do not appear in the standard MIBs or for agents that don't support the standard Index of Call Set Up Time.
INT prtIsdnStatusDspMode1.3.6.1.4.1.164.3.2.3.1.16.1.1INTEGERread-onlyThe DSP can be in one of the following Modes: Voice, Idle, Fax, Voice Band Data (VBD)- Modem.
INT prtIsdnStatusCallState1.3.6.1.4.1.164.3.2.3.1.16.1.2INTEGERread-onlyThe state that the current call is in.
STR prtIsdnStatusCallingNumber1.3.6.1.4.1.164.3.2.3.1.16.1.3DisplayStringread-onlyThis is the local Number (ISDN Address) associated with this entry.
STR prtIsdnStatusCalledNumber1.3.6.1.4.1.164.3.2.3.1.16.1.4DisplayStringread-onlyThis is the remote Number (ISDN Address) associated with this entry.
IP prtIsdnStatusCalledIP1.3.6.1.4.1.164.3.2.3.1.16.1.5IpAddressread-onlyThis is the remote IP Address associated with this entry.
INT prtIsdnStatusCallDirection1.3.6.1.4.1.164.3.2.3.1.16.1.6INTEGERread-onlyAttribute indicating the Direction of the Call. The value of notApplicable will be used for example when prtIsdnStatusCallState = notActive(14).
cnfgPrtMux1.3.6.1.4.1.164.3.2.3.2
prtClCnfg1.3.6.1.4.1.164.3.2.3.2.1
prtExClCnfgTable1.3.6.1.4.1.164.3.2.3.2.1.1not-accessibleA table.
prtExClCnfgEntry1.3.6.1.4.1.164.3.2.3.2.1.1.1not-accessibleAll the entries at this table are identical (have the same value) for all the configurations (1..100) except the TmpCnfg. The write operation into the Table Objects is valid only to the TmpCnfg entry.
I32 prtExClCnfgIdx1.3.6.1.4.1.164.3.2.3.2.1.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtExClSltIdx1.3.6.1.4.1.164.3.2.3.2.1.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. Because the second Cl is only for redundancy, all the parameters are identical in the two modules, i.e. change of any parameter in one module will change automatically the value of the other module.. In the ?004 Unit the entry clB(4) is not valid.
INT prtExClPrtIdx1.3.6.1.4.1.164.3.2.3.2.1.1.1.3INTEGERread-onlyThis attribute indicates a unique port number.
INT prtExClUsage1.3.6.1.4.1.164.3.2.3.2.1.1.1.4INTEGERread-onlyThis attribute indicates what is the usage of the port.
INT prtExClRate1.3.6.1.4.1.164.3.2.3.2.1.1.1.5INTEGERread-onlyThis attribute indicates the operation rate of the port.
INT prtExClDataBits1.3.6.1.4.1.164.3.2.3.2.1.1.1.6INTEGERread-onlyThis attribute indicates the number of data bits in async frame
INT prtExClParity1.3.6.1.4.1.164.3.2.3.2.1.1.1.7INTEGERread-onlyThis attribute indicates if the parity operation mode in async frame
INT prtExClStopBits1.3.6.1.4.1.164.3.2.3.2.1.1.1.8INTEGERread-onlyThis attribute indicates the minimum number of stop bits in the tx async frame
INT prtExClRoutingProtocol1.3.6.1.4.1.164.3.2.3.2.1.1.1.9INTEGERread-onlyThis attribute indicates the routing protocol of the port. When prtExClUsage is nmsSlip or nmsPpp - all values are applicable . Else - only 'none' is applicable.
INT prtExClEnabled1.3.6.1.4.1.164.3.2.3.2.1.1.1.10INTEGERread-onlyThis attribute indicates if Ethernet port of CL is enabled or not for management. It is applicable only on the ETH port of the CL, when the MP includes an ML-IP card. disabled - will happen when there is Inband Management via the ML-IP link/s enabled - will happen when ML-IP link/s is not used for Inband Management, but CL's ETH port .
prtPh1MlCnfg1.3.6.1.4.1.164.3.2.3.2.2
prtExPh1MlCnfgTable1.3.6.1.4.1.164.3.2.3.2.2.1not-accessible- For products supporting more than one configuration, the write operation into the Table is valid only to the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table will be to prtExPh1MlCnfgIdx=1.
prtExPh1MlCnfgEntry1.3.6.1.4.1.164.3.2.3.2.2.1.1not-accessibleAn entry in table.
I32 prtExPh1MlCnfgIdx1.3.6.1.4.1.164.3.2.3.2.2.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtExPh1MlSltIdx1.3.6.1.4.1.164.3.2.3.2.2.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid. For the Vmux2100 Main Board notApplicable (1) is used.
INT prtExPh1MlPrtIdx1.3.6.1.4.1.164.3.2.3.2.2.1.1.3INTEGERread-onlyThis attribute indicates a unique port number. MP-2100/2200: MTML-1/E1 and MTML-1/T1 cards have only one external interface. inPrt1, inPrt2 - for MTML-H/2E1 and HSH cards. inPrt1..inPrt4 - for MTML-E2 and MSL-4 cards. exPrt2..exPrt4 - for MTML-4 cards and others exPrt1..exPrt8 - for ML-8 cards. inPrt1..inPrt8 - for MSL-8 and VF-30 card family. MP-104/204: only exPrt3 (3) is applicable. MP-4100: intPrt1...intPrt84 - for CLX cards. For other products' index see their specification.
INT prtExPh1MlConnect1.3.6.1.4.1.164.3.2.3.2.2.1.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the card considerations because it may indicate that the module has only one physical interface.
INT prtExPh1MlLineType1.3.6.1.4.1.164.3.2.3.2.2.1.1.5INTEGERread-writeThis attribute is the line type parameter for T1/E1 interface. The user should select only the values which are relevant to the specific port: (2),(3), (8) - for T1 port (4)..(7), (9) - for E1 port. (101) framed - This value does not exist in standard MIB and is used for a non-standard E1 port that doesn't has real framer. Note: for old devices, g732unframed(8) was used as E1 Unframed. That was because at the time this value did not exist in the standard MIB (RFC-1406), so we added it in private MIB. Now that it was added to standard MIB, private MIB was updated as well. This parameter has the same values as dsx1LineType in DS1 MIB (RFC-3895). The parameters in dsx1LineType are: other (1) esfT1 dsx1ESF (2) sfT1 dsx1D4 (3) g732nE1 dsx1E1 (4) g732nE1CRC dsx1E1-CRC (5) g732sE1 dsx1E1-MF (6) g732sE1CRC dsx1E1-MF-CRC (7) g732unframed dsx1Unframed (8) --from RFC-3895 e1Unframed dsx1E1Unframed (9) --from RFC-3895
INT prtExPh1MlLineCode1.3.6.1.4.1.164.3.2.3.2.2.1.1.6INTEGERread-writeThis attribute is the line code parameter used for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for MPH.1/T1 E1 line code parameters for MPH.1/E1. This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)
INT prtExPh1MlLineLen1.3.6.1.4.1.164.3.2.3.2.2.1.1.7INTEGERread-writeThis attribute is the line length parameter used only for T1/DSU interfaces. lenXXXpXXXft = len-XXX-XXXft.
INT prtExPh1MlRestoreTime1.3.6.1.4.1.164.3.2.3.2.2.1.1.8INTEGERread-writeThe time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface.
INT prtExPh1MlTxGain1.3.6.1.4.1.164.3.2.3.2.2.1.1.9INTEGERread-writeThis attribute is the tx gain parameter used only for T1/CSU interfaces.
INT prtExPh1MlRxSensitivity1.3.6.1.4.1.164.3.2.3.2.2.1.1.10INTEGERread-writeThis attribute is the rx line sensitivity parameter. low26dBm, high36dBm - applicable for T1-CSU shortHaul, longHaul - applicable for MTML-4 cards low15dbm was added for vmux110/210 T1 ports.
I32 prtExPh1MlIdleCode1.3.6.1.4.1.164.3.2.3.2.2.1.1.11Integer32read-writeDetermines the code for transmission in empty time slots. Type value(00-FFH), Excluding 0H,8H,10H,12H,21H,24H,42H,49H, 84H,92H
INT prtExPh1MlTdmTrunk1.3.6.1.4.1.164.3.2.3.2.2.1.1.12INTEGERread-writeThis attribute indicates whether the port is used to transfer TDM cards data and through which Bus.
INT prtExPh1MlClkMode1.3.6.1.4.1.164.3.2.3.2.2.1.1.13INTEGERread-writeDefines the clock operation mode of the T1/E1 interface. Ports that are connected to the TDM Buses must be in nodalTiming(3) clock mode.
INT prtExPh1MlMfClkSrcSlt1.3.6.1.4.1.164.3.2.3.2.2.1.1.14INTEGERread-writeThis attribute indicates whether the port Tx multiframe is synchronized with Rx multiframe of another port and the slot position of that port. This operation is required in order to bypass signaling of PCM voice channels. Its value is always local(2) when the port isn't connected to any TDM bus. When it's value is local(2) there is no meaning to 'prtExPh1MlMfClkSrcPrt' parameter. In the ?004 Unit the entries io6(10)..io16) are not valid
INT prtExPh1MlMfClkSrcPrt1.3.6.1.4.1.164.3.2.3.2.2.1.1.15INTEGERread-writeA unique number to identify a port position in the mux. It has no effect when the prtExPh1MlMfClkSrcSlt selected is Local. inPrt1 - for MTML-H/E1 cards.
INT prtExPh1MlFdlType1.3.6.1.4.1.164.3.2.3.2.2.1.1.16INTEGERread-writeA unique number to identify the side of the FDL operation. Normal: 'response' for the user side and 'command' for the PTT side. Applicable only when working with ESF-T1 link
INT prtExPh1MlInbandMng1.3.6.1.4.1.164.3.2.3.2.2.1.1.17INTEGERread-writeA unique number to identify an Inband management over the link.
INT prtExPh1MlInbandMngRate1.3.6.1.4.1.164.3.2.3.2.2.1.1.18INTEGERread-writeA unique number to identify the rate of the Inband management (Kbps). E1 port - it is not applicable when prtExPh1MlInbandMng selected is off. T1 port - it is not applicable when prtExPh1MlInbandMng selected is off OR fdlOrTs0.
INT prtExPh1MlRedundType1.3.6.1.4.1.164.3.2.3.2.2.1.1.19INTEGERread-writeThis object determines the ML redundancy type: none - no ML redundacy dualCableAIS - each ML card is connected by a separate dualCableParallelTx cable to the other MUX (two cables connect two MUXes). There are two types of dual redundancy. yCable - Y cable is connected to both ML cards (one cable connects two MUXes). Default=none When only one ML card exists, the type can be only 'none'. The value should be the same for both ML slots.
INT prtExPh1MlRedundSlot1.3.6.1.4.1.164.3.2.3.2.2.1.1.20INTEGERread-writeThis object indicates the slot containing the redundacy ML card, coupled with the current ML (prtExPh1MlSltIdx). When prtExPh1MlRedundType=none (no ML redundancy) this object will be 'notApplicable'. In the ?004 Unit the entries io6(10)..io12(16) are not valid When value is not 'none', it should be mutual to the redundant ML slot.
INT prtExPh1MlRedundPort1.3.6.1.4.1.164.3.2.3.2.2.1.1.21INTEGERread-writeThis object indicates the redundacy ML port, coupled with the current ML port (prtExPh1MlPrtIdx). When prtExPh1MlRedundType=none (no ML redundancy) this object will be 'notApplicable'. When value is not 'none', it should be mutual to the redundant ML port. inPrt1 - for MTML-H/E1 cards. inPrt1..inPrt4 - for MTML-E2 cards. exPrt2..exPrt4 - for MTML-4 cards.
I32 prtExPh1MlRedundRecTime1.3.6.1.4.1.164.3.2.3.2.2.1.1.22Integer32read-writeRedundancy Recovery Time (sec). After switching the ML card to the current (prtExPh1MlSltIdx), the next ML switch can be performed only after a minimum time, indicated by this object.
INT prtExPh1MlInbandMngRoutProt1.3.6.1.4.1.164.3.2.3.2.2.1.1.23INTEGERread-writeThis attribute indicates the Inband Mng routing protocol of the port.
INT prtExPh1MlIfType1.3.6.1.4.1.164.3.2.3.2.2.1.1.24INTEGERread-writeInterface type of the port. For T1 - csu, dsu are the valid values For E1 - dsu, ltu are the valid values.
INT prtExPh1MlMultiplier1.3.6.1.4.1.164.3.2.3.2.2.1.1.25INTEGERread-writeThe data rate of each TS. The multiplier values can be 56 kbps or 64 kbps.
I32 prtExPh1MlSupportedTS1.3.6.1.4.1.164.3.2.3.2.2.1.1.26Integer32read-onlyNumber of Supported Time Slots by the agent. For Vmux-110 there is HW that supports less than 31/24 Time Slots for the E1/T1 port.
INT prtExPh1MlImpedance1.3.6.1.4.1.164.3.2.3.2.2.1.1.27INTEGERread-writeThe Line Impedance. For T1 (always balanced), impedance is 100 ohm. For E1: - balanced = 120 ohm - unbalanced = 75 ohm.
INT prtExPh1MlQ50BwControl1.3.6.1.4.1.164.3.2.3.2.2.1.1.28INTEGERread-writeThis object enables configuration of Q.50 Bandwidth Control on the port. If the bandwidth exceeds a certain threshold it is possible to disable new calls in the PBX via Q.50 protocol. Q.50 supports only E1 ports with Line Types: E1-MF (G.732S), E1-CRC-MF(G.732SCRC ) It does not support T1 ports. Annex A - the basic type of Q.50 which focuses only on the bandwidth control. Can use one of the following pairs of signaling bits: A&B or C&D. Annex B - Expansion of Annex A which includes also call release messages and Maintenance Messages. Uses A&B bits only.
INT prtExPh1MlQ50SignalPair1.3.6.1.4.1.164.3.2.3.2.2.1.1.29INTEGERread-writeQ.50 Signaling bits Pair that is currently in use: A&B bits or C&D bits. For Annex B it will always be: aAndB (2).
INT prtExPh1MlInternalSwitch1.3.6.1.4.1.164.3.2.3.2.2.1.1.30INTEGERread-writeThis parameter shows whether the data will be transferred from one port to the other port within the same group of 2 ports. The default value is: Enable. Disable value might be necessary for security implementations or for ring applications. For Vmux-2100 device this parameter is used on the Channelized Cards. Both ports in each group should have the same value for this parameter.
INT prtExPh1MlSigService1.3.6.1.4.1.164.3.2.3.2.2.1.1.31INTEGERread-writeSignaling Service given by this link. notApplicable - for T1 links normal - usual Signaling advanced - V5 Signaling.
I32 prtExPh1MlFragmentSize1.3.6.1.4.1.164.3.2.3.2.2.1.1.32Integer32read-writeThis parameter indicates the maximum number of bytes permitted in a packet send over the Link. Exceeding this size will cause packet fragmentation.
prtExPh1MlTsTable1.3.6.1.4.1.164.3.2.3.2.2.2not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry, except prtExPh1MlTsTest that will be written directly to the Active Configuration.
prtExPh1MlTsEntry1.3.6.1.4.1.164.3.2.3.2.2.2.1not-accessibleAn entry in table.
I32 prtExPh1MlTsCnfgIdx1.3.6.1.4.1.164.3.2.3.2.2.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtExPh1MlTsSltIdx1.3.6.1.4.1.164.3.2.3.2.2.2.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid. For the Vmux2100 Main Board notApplicable (255) is used.
INT prtExPh1MlTsPrtIdx1.3.6.1.4.1.164.3.2.3.2.2.2.1.3INTEGERread-onlyThis attribute indicates a unique port number. MPH.1/E1 and MPH.1/T1 cards have only one external interface. exPrt2 - for ME1-2, MT1-2 and mhsPri cards. exPrt3, exPrt4 - for mhsPri cards. inPrt1 - for MTML-H/E1 cards.
I32 prtExPh1MlTsIdx1.3.6.1.4.1.164.3.2.3.2.2.2.1.4Integer32read-onlyThis attribute indicates a unique time slot position. The valid time slots are 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling.
INT prtExPh1MlTsIConSlot1.3.6.1.4.1.164.3.2.3.2.2.2.1.5INTEGERread-writeThis attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io16) are not valid. split - will be used when the Src TS is connected to more than one slot OR more than one port (each needing less than a whole TS).
I32 prtExPh1MlTsIConPrt1.3.6.1.4.1.164.3.2.3.2.2.2.1.6Integer32read-writeThis attribute indicates the internally (In Mux) connected/routed port. For MP, the values will be: { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) } For other products see specific values at spec.
I32 prtExPh1MlTsIConTs1.3.6.1.4.1.164.3.2.3.2.2.2.1.7Integer32read-writeThis attribute indicates a unique time slot position. The valid time slots are 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated to multiframe synchronization and voice signaling.
OID prtExPh1MlTsExt1.3.6.1.4.1.164.3.2.3.2.2.2.1.8OBJECT IDENTIFIERread-onlyA pointer to an extension of this table: prtExTsSplitTable. - If prtExPh1MlTsIConSlot='split', its value should be set to the OBJECT IDENTIFIER of the prtExTsSplitTable, with its relevant CnfgIdx, SltIdx, PrtIdx, TsIdx and 1st TsBit. - If prtExPh1MlTsIConSlot is not 'split', its value should be set to the OBJECT IDENTIFIER { 0 0 }.
INT prtExPh1MlTsTest1.3.6.1.4.1.164.3.2.3.2.2.2.1.9INTEGERread-writeThis attribute indicates a test to be activated on the selected TS. It is applicable only when prtSTstCmd=testPerTS(31). notApplicable - when prtSTstCmd is NOT testPerTS(31). none - no test is applied for the selected TS. split - when the tests are per Bit of the selected TS.
INT prtExPh1MlTsType1.3.6.1.4.1.164.3.2.3.2.2.2.1.10INTEGERread-writeThe Time Slot Type. Transparent - means that the Time Slot will be Rx/Tx as is without processing it. If the device requires more than 1 unique data or ss7 Time Slot, options with numbers can be used like: data...data4. Each numbered Type can go to a different destination. ss7n2 - means the 2nd group of ss7 Time Slots. data2,data3, data4 mean group 2,3,4 of Data Time Slots. subCh1...subCh8 mean Sub Channel 1...8, respectively. trau, qmux, dynamic, signaling - are used by GSM devices.
I32 prtExPh1MlTsBundle1.3.6.1.4.1.164.3.2.3.2.2.2.1.11Integer32read-writeThe number of the bundle containing this Time Slot. If no bundle exists for this TS or the bundle number is irrelevant, the value will be 0.
I32 prtExPh1MlTsTestDuration1.3.6.1.4.1.164.3.2.3.2.2.2.1.12Integer32read-writeThis attribute indicates the maximum duration of executing a test on the specific TS. This entry applies to all the test operations. For the Vmux2100 the values are: 0 - 60 seconds. A zero value specifies no time limitation. When the test isn't active, the agent initiates this object to 2 when the duration is needed and to 0 if its not required. The user should set this parameter after setting the 'prtExPh1MlTsTest' parameter.
INT prtExPh1MlTsSubChType1.3.6.1.4.1.164.3.2.3.2.2.2.1.13INTEGERread-writeThe Time Slot Sub-Channel Type. This variable is relevant only when Time-Slot Type is SubCh (e.g. prtExPh1MlTsType = subCh1...subCh8).
I32 prtExPh1MlTsSubChMask1.3.6.1.4.1.164.3.2.3.2.2.2.1.14Integer32read-writeThe Sub-Channel Type Mask. This variable is relevant only when Time-Slot Type is SubCh (e.g. prtExPh1MlTsType = subCh1...subCh8).
INT prtExPh1MlTsChRate1.3.6.1.4.1.164.3.2.3.2.2.2.1.15INTEGERread-writeThe Rate of the Signaling Channel. notApplicable(1) when TS Type is other than Signaling or Transparent
INT prtExPh1MlTsByteReversal1.3.6.1.4.1.164.3.2.3.2.2.2.1.16INTEGERread-writeByte Reversal. This variable defines whether the LSB or MSB is transmitted first. no(2) - MSB is transmitted first yes(3) - LSB is transmitted first.
INT prtExPh1MlTsSigProfile1.3.6.1.4.1.164.3.2.3.2.2.2.1.17INTEGERread-writeThis object indicates the Signaling Profile of the port. It is applicable only when prtMl4SigProfile=perTS. p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4 p5 = profile 5
prtInPh1MlCnfgTable1.3.6.1.4.1.164.3.2.3.2.2.3not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtInPh1MlCnfgEntry1.3.6.1.4.1.164.3.2.3.2.2.3.1not-accessibleAn entry in table.
I32 prtInPh1MlCnfgIdx1.3.6.1.4.1.164.3.2.3.2.2.3.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtInPh1MlSltType1.3.6.1.4.1.164.3.2.3.2.2.3.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. For ISDN BRI port of MX300/30: io1(5) = isdn1(5) and io2(6) = isdn2(6) In the ?004 Unit the entries io6(10)..io12(16) are not valid
I32 prtInPh1MlPrtIdx1.3.6.1.4.1.164.3.2.3.2.2.3.1.3Integer32read-onlyThis attribute indicates a unique port number. MPH.1/E1 and MPH.1/T1 cards have three internal interfaces. MX3000 modules may have up to 50 internal ports.
INT prtInPh1MlConnect1.3.6.1.4.1.164.3.2.3.2.2.3.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtInPh1MlRate1.3.6.1.4.1.164.3.2.3.2.2.3.1.5INTEGERread-writeThis attribute indicates the port speed.
INT prtInPh1MlProtocol1.3.6.1.4.1.164.3.2.3.2.2.3.1.6INTEGERread-writeThis attribute indicates the applied protocol.
INT prtInPh1MlConnectionTyp1.3.6.1.4.1.164.3.2.3.2.2.3.1.7INTEGERread-writeThis attribute indicates the link connection type. It is required for three reasons: FR/CR Inband management operation (LMI,CLMM...). CIR check. NMS network management. SameNetManaged - indicates network internal line. SameNetNotMana - indicates network internal line, but the remote mux is not managed by the nms. User - User to Network Interface. OtherNet - Network To Network Interfce. PubNet - Access Mux To PubNet Interface.
INT prtInPh1MlCongResponse1.3.6.1.4.1.164.3.2.3.2.2.3.1.8INTEGERread-writeThis attribute indicates how to handle the congestion indication to/from the mux internal connection side (for example transmit/receive becn to/from the network). no - do nothing FlowControl - translate the congestion indication between the port and the internal connection port according to the definition of the prtInPh1MlFlowControl parameters. The operation is done in both directions.
I32 prtInPh1MlCongLevel1.3.6.1.4.1.164.3.2.3.2.2.3.1.9Integer32read-writeThis attribute indicates the level of delayed data in precents of the total available dynamic memory, for which the port will start to operate . The resolution of the parameter is 5 percent. Valid values: 10..70, 255. 255=notApplicable.
INT prtInPh1MlTc1.3.6.1.4.1.164.3.2.3.2.2.3.1.10INTEGERread-writeThis attribute indicates the Tc parameter which is the time period of the sliding window in which the Bc/Be are tested. The value of this parameter is identical for all the ports in the specific card. 255=notApplicable.
INT prtInPh1MlFlowControl1.3.6.1.4.1.164.3.2.3.2.2.3.1.11INTEGERread-writeThis attribute indicates the required flow control betweeen the port and the remote equipment.
INT prtInPh1MlSegment1.3.6.1.4.1.164.3.2.3.2.2.3.1.12INTEGERread-writeThis object is the Segmentation in Bytes. In protocol FR+, ISDN internals, MX 30/300 the segmentation is: 50 (2) ,158 (3) ,266 (4) ,376 (5), 484 (6) In MX 3000/4: For protocol FR+ (internal ISDN ports of MHS.S, MHS.U, MHS.E1, MHS.T1 cards) segmentation values are: 236 (7),472 (8), 708 (9), 944 (10) ,1180 (11)
INT prtInPh1MlFrMngProt1.3.6.1.4.1.164.3.2.3.2.2.3.1.13INTEGERread-writeThis object indicates the Frame-Relay management protocol. ansiT1 = ANSI T1.617 Annex D (this is the default value). This parameter is applicable only for FR and FR+ protocols. When prtInPh1MlConnectionTyp = sameNetManaged, this object will be RO (internally determined).
I32 prtInPh1MlEnqPeriod1.3.6.1.4.1.164.3.2.3.2.2.3.1.14Integer32read-writeThis object is the Status Enquiry Period, in seconds. It determines the frequency of the Status Enquiry message as sent by the FR user side. At the FR network side, it determines the timeout for this message reception. Default = 4 seconds. This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
I32 prtInPh1MlFullRptPeriod1.3.6.1.4.1.164.3.2.3.2.2.3.1.15Integer32read-writeThis object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite (never sent). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
I32 prtInPh1MlFrWindowSize1.3.6.1.4.1.164.3.2.3.2.2.3.1.16Integer32read-writeThis object is the FR Window Size. It determines the number of samplings in the sliding window that counts the errors. This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
I32 prtInPh1MlErrorsThreshold1.3.6.1.4.1.164.3.2.3.2.2.3.1.17Integer32read-writeThis object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
I32 prtInPh1MlMaxIdleTime1.3.6.1.4.1.164.3.2.3.2.2.3.1.18Integer32read-writeMove to higher prioritized connected link after this period of seconds of silence on the current link. 0=Never. Never move to higher prioritized connected link. UNIT is seconds. Valid values are: 0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60, 120, 180, 240, 300, 360, 420, 480, 540, 600, 900, 1200, 1500, 1800. Attempt to Set an invalid value will result in getting the default value.
INT prtInPh1MlBearerCh1.3.6.1.4.1.164.3.2.3.2.2.3.1.19INTEGERread-writeDefines which B (bearer) channels are used for transferring ISDN data. Default value is: none (255). anyChannel (2) is skipped because it is not in use here.
INT prtInPh1MlAssociatedExCh1.3.6.1.4.1.164.3.2.3.2.2.3.1.20INTEGERread-writeThis object indicates the external port associated to this internal port. At present, it is used by the Hybrid (mp2100h), MHS-4 cards which can have up to 64 dynamic internal ports associated with External ports. For ISDN cards, the value will be: notApplicable (255). The associated external of an ISDN internal port is represented by the MIB object: prtIsdnDirectoryPrtNu.
INT prtInPh1MlClockEncoding1.3.6.1.4.1.164.3.2.3.2.2.3.1.21INTEGERread-writeThis object is the Encoding type of the Line. This parameter is applicable only for FR and FR+ protocols.
I32 prtInPh1MlMinSeparators1.3.6.1.4.1.164.3.2.3.2.2.3.1.22Integer32read-writeMinimum number of bytes separating between two adjacent frames (HDLC item). 0 = notApplicable
INT prtInPh1MlCcittCrc1.3.6.1.4.1.164.3.2.3.2.2.3.1.23INTEGERread-writeThis object indicates how many Bits are used for CRC (HDLC item).
INT prtInPh1MlFrameSeparator1.3.6.1.4.1.164.3.2.3.2.2.3.1.24INTEGERread-writeThis object indicates what should be transferred on the line when there are no frames to pass (HDLC item). idles: mean that FF will pass on the line flags: mean that 7E will pass on the line.
prtInPh1MlDlciTable1.3.6.1.4.1.164.3.2.3.2.2.4not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtInPh1MlDlciEntry1.3.6.1.4.1.164.3.2.3.2.2.4.1not-accessibleAn entry in table.
I32 prtInPh1MlDlciCnfgIdx1.3.6.1.4.1.164.3.2.3.2.2.4.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtInPh1MlDlciSltIdx1.3.6.1.4.1.164.3.2.3.2.2.4.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
INT prtInPh1MlDlciPrtIdx1.3.6.1.4.1.164.3.2.3.2.2.4.1.3INTEGERread-onlyThis attribute indicates a unique internal port number. MPH.1/E1 and MPH.1/T1 cards have three internal ports.
I32 prtInPh1MlDlciIdx1.3.6.1.4.1.164.3.2.3.2.2.4.1.4Integer32read-onlyThis attribute indicates a unique index for each possible used dlci(16..991). When the protocol is not Multiplexing protocol, then its type is 'user' and the only valid index is 1.
INT prtInPh1MlDlciValid1.3.6.1.4.1.164.3.2.3.2.2.4.1.5INTEGERread-writeThis attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object
INT prtInPh1MlDlciIConSlt1.3.6.1.4.1.164.3.2.3.2.2.4.1.6INTEGERread-writeThis attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. In the ?004 Unit the entries io6(10)..io16) are not valid
INT prtInPh1MlDlciIConPrt1.3.6.1.4.1.164.3.2.3.2.2.4.1.7INTEGERread-writeThis attribute indicates a unique port id which the dlci is routed to.
I32 prtInPh1MlDlciIConDlci1.3.6.1.4.1.164.3.2.3.2.2.4.1.8Integer32read-writeThis attribute indicates a unique internal connection dlci number which the src dlci is routed to.
INT prtInPh1MlDlciTxBc1.3.6.1.4.1.164.3.2.3.2.2.4.1.9INTEGERread-writeThis attribute indicates a unique Tx committed bandwidth on the user transmit line or at the port receive line.
INT prtInPh1MlDlciTxBe1.3.6.1.4.1.164.3.2.3.2.2.4.1.10INTEGERread-writeThis attribute indicates a unique Tx excess bandwidth on the user transmit line or at the port receive line.
INT prtInPh1MlDlciRxBc1.3.6.1.4.1.164.3.2.3.2.2.4.1.11INTEGERread-writeThis attribute indicates a unique Rx committed bandwidth on the user receive line or at the port transmit line.
INT prtInPh1MlDlciRxBe1.3.6.1.4.1.164.3.2.3.2.2.4.1.12INTEGERread-writeThis attribute indicates a unique Rx excess bandwidth on the user receive line or at the port transmit line.
I32 prtInPh1MlDlciPriority1.3.6.1.4.1.164.3.2.3.2.2.4.1.13Integer32read-writeThis attribute indicates a unique priority of the pcv. 1 is the lowest priority and 8 is the highest priority.
INT prtInPh1MlDlciStatus1.3.6.1.4.1.164.3.2.3.2.2.4.1.14INTEGERread-onlyThis attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
prtPhMlCnfgTable1.3.6.1.4.1.164.3.2.3.2.2.5not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtPhMlCnfgEntry1.3.6.1.4.1.164.3.2.3.2.2.5.1not-accessibleAn entry in table.
I32 prtPhMlCnfgIdx1.3.6.1.4.1.164.3.2.3.2.2.5.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtPhMlSltIdx1.3.6.1.4.1.164.3.2.3.2.2.5.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For the Vmux2100 Main Board notApplicable (1) is used.
INT prtPhMlPrtIdx1.3.6.1.4.1.164.3.2.3.2.2.5.1.3INTEGERread-onlyThis attribute indicates a unique port number. ML-20 cards have just one external interface.
INT prtPhMlConnect1.3.6.1.4.1.164.3.2.3.2.2.5.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtPhMlRate1.3.6.1.4.1.164.3.2.3.2.2.5.1.5INTEGERread-writeThis attribute indicates the configured port speed. auto - rate is adapted automatically to the attached modem rate.
INT prtPhMlCAS1.3.6.1.4.1.164.3.2.3.2.2.5.1.6INTEGERread-writeThis attribute indicates whether Channel Associated Signaling (CAS) is used.
INT prtPhMlClockMode1.3.6.1.4.1.164.3.2.3.2.2.5.1.7INTEGERread-writeClock mode.
INT prtPhMlSatBuffer1.3.6.1.4.1.164.3.2.3.2.2.5.1.8INTEGERread-writeSatellite Buffer (+/- 256).
INT prtPhMlDialProcess1.3.6.1.4.1.164.3.2.3.2.2.5.1.9INTEGERread-writeDial Process.
I32 prtPhMlSyncRestore1.3.6.1.4.1.164.3.2.3.2.2.5.1.10Integer32read-writeSync Restoration time, in seconds. notApplicable=0.
INT prtPhMlBus1.3.6.1.4.1.164.3.2.3.2.2.5.1.11INTEGERread-writeThe TDM BUS this port is linked to.
INT prtPhMlMfSyncSlot1.3.6.1.4.1.164.3.2.3.2.2.5.1.12INTEGERread-writeThis attribute indicates whether the sync is synchronized according to a certain card and the slot of this card. This operation is required in order to bypass signaling of PCM voice channels. In the ?004 Unit the entries io6(10)..io12(16) are not valid
INT prtPhMlClockSource1.3.6.1.4.1.164.3.2.3.2.2.5.1.13INTEGERread-writeThe Clock Source: TC (Tx Clock) or RC (Rx Clock) signals.
INT prtPhMlErrCorrection1.3.6.1.4.1.164.3.2.3.2.2.5.1.14INTEGERread-writeThis object indicates if Error Correction mechanism should be applied or not. It will be applicable only if the interface HW includes the Error Correction chip.
INT prtPhMlCorrectionMode1.3.6.1.4.1.164.3.2.3.2.2.5.1.15INTEGERread-writeThis object is applicable only when prtPhMlErrCorrection=yes. random - enables to correct up to 3 random errors in an 23 bit frame built from 12 data bits and 11 appended parity bits. bursty - interleaving 3 frames, allows correcting bursts of 9 bit length.
INT prtPhMlControlSignals1.3.6.1.4.1.164.3.2.3.2.2.5.1.16INTEGERread-writeThis object shows whether the Port will ignore or implement the control signals like DCD, CTS, DTR.
INT prtPhMlInterfaceType1.3.6.1.4.1.164.3.2.3.2.2.5.1.17INTEGERread-writeThe SW Configurable Interface Type.
INT prtPhMlClockPolarity1.3.6.1.4.1.164.3.2.3.2.2.5.1.18INTEGERread-writeThis object indicates the clock polarity.
prtPhPlCnfg1.3.6.1.4.1.164.3.2.3.2.3
prtExPhPlCnfgTable1.3.6.1.4.1.164.3.2.3.2.3.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExPhPlCnfgEntry1.3.6.1.4.1.164.3.2.3.2.3.1.1not-accessibleAn entry in table.
I32 prtExPhPlCnfgIdx1.3.6.1.4.1.164.3.2.3.2.3.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtExPhPlSltIdx1.3.6.1.4.1.164.3.2.3.2.3.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid
INT prtExPhPlPrtIdx1.3.6.1.4.1.164.3.2.3.2.3.1.1.3INTEGERread-onlyThis attribute indicates a unique port number. In case of PH.1 card, only exPrt(1) is valid.
INT prtExPhPlConnect1.3.6.1.4.1.164.3.2.3.2.3.1.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtExPhPlHRate1.3.6.1.4.1.164.3.2.3.2.3.1.1.5INTEGERread-writeThis attribute indicates the port speed for HIGH speed cards. The card has limitations about the maximum sigma channel speeds and about the possible rates for each clock mode . N - The rate is valid for DCE and EXT-DCE Nodal clock mode. L - The rate is valid for DCE and EXT-DCE Local clock mode. E - The rate is valid for DTE External clock mode. 'r9d6KbpsNLE' means rate of 9.6 Kbps ('d'=dot). Note: Some rate attributes have been changed. As the MIB was already released with the old attributes, the names of the options were not changed. The new names + attributes are in a comment. Example: r2048KbpsE (63), -- r2048KbpsNLE
INT prtExPhPlLRate1.3.6.1.4.1.164.3.2.3.2.3.1.1.6INTEGERread-writeThis attribute indicates the port speed for LOW speed cards. The card has limitations about the possible rates for each clock mode. N - The rate is valid for DCE and EXT-DCE Nodal clock mode. L - The rate is valid for DCE and EXT-DCE Local clock mode. E - The rate is valid for DTE External clock mode. Note: Some rate attributes have been changed. As the MIB was already released with the old attributes, the names of the options were not changed. The new names + attributes are in a comment. Example: r57600bpsLE (16), -- r57600bpsNLE
INT prtExPhPlProtocol1.3.6.1.4.1.164.3.2.3.2.3.1.1.7INTEGERread-writeThis object indicates the applied protocol.
INT prtExPhPlConnectionTyp1.3.6.1.4.1.164.3.2.3.2.3.1.1.8INTEGERread-writeThis attribute indicates the link connection type. It is required for three reasons: FR/CR Inband management opration (LMI,CLMM...). CIR check. NMS network management. SameNetManaged - indicates network internal line. SameNetMotMana - indicates network internal line, but the remote mux is not managed by the NMS. User - User to Network Interface. OtherNet - Network To Network Interface. PubNet - Access Mux To PubNet Interface.
INT prtExPhPlClkMode1.3.6.1.4.1.164.3.2.3.2.3.1.1.9INTEGERread-writeClock mode.
INT prtExPhPlDceClkSrc1.3.6.1.4.1.164.3.2.3.2.3.1.1.10INTEGERread-writeThis attribute indicates the source of the clock when working in dce or ext-dce clock mode. notApplicable(1) - is applied for dte(3) and lbt(5) clock modes. When clock mode is dte, the clock source is always external, therefore this object's value is notApplicable. local(2) and nodalTiming(3) - are valid in dce(1), extDce(2) or int(4) clock modes. The recommended clock source is local(2).
INT prtExPhPlCongResponse1.3.6.1.4.1.164.3.2.3.2.3.1.1.11INTEGERread-writeThis attribute indicates how to handle the congestion indication to/from the mux internal connection side (for example transmit/received becn to/from the network). no - do nothing flowControl - translates the congestion indication between the port and the internal connection port according to the definition of the prtInPh1MlFlowControl parameters. The operation is done on both directions. toFlowControl- translates the backward congestion indication received from the internal connection port (normally the network side) to flow control and do nothing in the other direction.
I32 prtExPhPlCongLevel1.3.6.1.4.1.164.3.2.3.2.3.1.1.12Integer32read-writeThis attribute indicates the level of delayed data in precents of total available dynamic memory, for which the port will start to operate as congested. The resolution of the parameter is 5 percent.
INT prtExPhPlTc1.3.6.1.4.1.164.3.2.3.2.3.1.1.13INTEGERread-writeThis attribute indicates the Tc parameter which is the time period of the sliding window in which the Bc/Be are tested. The value of this parameter is identical for all the ports of a specific card .
INT prtExPhPlFlowControl1.3.6.1.4.1.164.3.2.3.2.3.1.1.14INTEGERread-writeThis attribute indicates the required flow control betweeen the port and the remote equipment. fecnBecn - is valid only for FR, FR+ and CR protocols. xonXoff,dtrCts - are valid only for Async protocols. speedReduction - is valid only for DLC protocol when the Clock Mode is DCE and the Clock Source is Local.
INT prtExPhPlDcdRts1.3.6.1.4.1.164.3.2.3.2.3.1.1.15INTEGERread-writeProtocol may require end to end connect indication over the network. End to end link connection establishment over the FR network will be indicated to the user by using DCD or RTS control signals, depending on the clock mode: DCE or DTE respectively. The options are : - On : DCD(DCE)/RTS(DTE) will be constantly ON no matter if the End to End connection is established or not. - End to End: The DCD(DCE)/RTS(DTE) will be according to the status of the End to End connection.
INT prtExPhPlDcdRtsControlPath1.3.6.1.4.1.164.3.2.3.2.3.1.1.16INTEGERread-writeProtocol may require end to end connect indication over the network. This parameter defines whether to take the user connection status (RTS(DCE)/DCD(DTE)) and forward it to the network side. - on : Transmit active connection to the network regardless the RTS/DCD control lines status. - off: Transmit active connection to the network according to the status of the RTS/DCD pin.
INT prtExPhPlDataBits1.3.6.1.4.1.164.3.2.3.2.3.1.1.17INTEGERread-writeThis attribute indicates the number of data bits in async frame. It is relevant only for Async protocols.
INT prtExPhPlParity1.3.6.1.4.1.164.3.2.3.2.3.1.1.18INTEGERread-writeThis attribute indicates the parity operation mode in async frame. It is relevant only for Async protocols.
INT prtExPhPlStopBits1.3.6.1.4.1.164.3.2.3.2.3.1.1.19INTEGERread-writeThis attribute indicates the minimum number of stop bits in the tx async frame. It is relevant only for Async protocols.
I32 prtExPhPlLXon1.3.6.1.4.1.164.3.2.3.2.3.1.1.20Integer32read-writeThis attribute indicates the character used as X-On to notify receive enable. This parameter is valid only for async protocols. Valid values: 0..255. The value 256 indicates that it's not applicable
I32 prtExPhPlLXoff1.3.6.1.4.1.164.3.2.3.2.3.1.1.21Integer32read-writeThis attribute indicates the character used as X-Off to notify receive disable. This parameter is valid only for async protocols. Valid values: 0..255. The value 256 indicates that it's not applicable
INT prtExPhPlFrMngProt1.3.6.1.4.1.164.3.2.3.2.3.1.1.22INTEGERread-writeThis object indicates the Frame-Relay management protocol. ansiT1 = ANSI T1.617 Annex D (this is the default value). This parameter is applicable only for FR and FR+ protocols. When prtExPhPlConnectionTyp = sameNetManaged, this object will be RO (internally determined).
I32 prtExPhPlEnqPeriod1.3.6.1.4.1.164.3.2.3.2.3.1.1.23Integer32read-writeThis object is the Status Enquiry Period, in seconds. It determines the frequency of the Status Enquiry message as sent by the FR user side. At the FR network side, it determines the timeout for this message reception. Default = 4 seconds. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
I32 prtExPhPlFullRptPeriod1.3.6.1.4.1.164.3.2.3.2.3.1.1.24Integer32read-writeThis object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
I32 prtExPhPlFrWindowSize1.3.6.1.4.1.164.3.2.3.2.3.1.1.25Integer32read-writeThis object is the FR Window Size. It determines the number of samplings in the sliding window that counts the errors. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
I32 prtExPhPlErrorsThreshold1.3.6.1.4.1.164.3.2.3.2.3.1.1.26Integer32read-writeThis object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
INT prtExPhPlPvcCreateMsg1.3.6.1.4.1.164.3.2.3.2.3.1.1.27INTEGERread-writeThis object is Update Message (if required or not). It determines whether a message of a New PVC Creation is requested or not (yes/no). Default = no. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
INT prtExPhPlCllmMsg1.3.6.1.4.1.164.3.2.3.2.3.1.1.28INTEGERread-writeThis object is CLLM Message (if required or not). It determines whether to send (or not) a congestion message when the port is Rx congested. Default = no. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
INT prtExPhPlProtDelayLevel1.3.6.1.4.1.164.3.2.3.2.3.1.1.29INTEGERread-writeThis object is the Segmentation in Bytes. In some cases, the enumerated values will mean other segmentation values than specified: Product: MX-3000 MX-3000 MX-300/MX-30 Protocol: FR+ Transparent FR+ ----------------------------------------------------- level 1 50 Bytes 44 Bytes 50 Bytes level 2 158 Bytes 155 Bytes 158 Bytes level 3 266 Bytes 266 Bytes 266 Bytes level 4 376 Bytes 377 Bytes 376 Bytes level 5 484 Bytes 488 Bytes 484 Bytes Defval=level 1 value This parameter is applicable only for FR+ and transparent protocols.
INT prtExPhPlClockEncoding1.3.6.1.4.1.164.3.2.3.2.3.1.1.30INTEGERread-writeThis object is the Encoding type of the Line. This parameter is applicable only for FR and FR+ protocols. For MAXCESS 3000 & MP2100H: when setting to nrzI (3) the nrzI works as nrzI Mark. For MAXCESS 30/300 when setting to nrzI (3) the nrzI works as nrzI Space.
I32 prtExPhPlMinSeparators1.3.6.1.4.1.164.3.2.3.2.3.1.1.31Integer32read-writeMinimum number of bytes separating between two adjacent frames (HDLC item). 0 = notApplicable
INT prtExPhPlCcittCrc1.3.6.1.4.1.164.3.2.3.2.3.1.1.32INTEGERread-writeThis object indicates how many Bits are used for CRC (HDLC item).
INT prtExPhPlFrameSeparator1.3.6.1.4.1.164.3.2.3.2.3.1.1.33INTEGERread-writeThis object indicates what should be transferred on the line when there are no frames to pass (HDLC item). idles: mean that FF will pass on the line flags: mean that 7E will pass on the line.
I32 prtExPhPlIdleCode1.3.6.1.4.1.164.3.2.3.2.3.1.1.34Integer32read-writeDetermines the code for transmission when there are no frames to transmit on the line. The value should be 0 to FFH.
I32 prtExPhPlJitter1.3.6.1.4.1.164.3.2.3.2.3.1.1.35Integer32read-writeMaximum variant delay of the FR network, in msec.
prtExPhPlDlciTable1.3.6.1.4.1.164.3.2.3.2.3.2not-accessibleThe write operation into the Table Objects is valid only at the TmpCnfg entry.
prtExPhPlDlciEntry1.3.6.1.4.1.164.3.2.3.2.3.2.1not-accessibleAn entry in table.
I32 prtExPhPlDlciCnfgIdx1.3.6.1.4.1.164.3.2.3.2.3.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtExPhPlDlciSltIdx1.3.6.1.4.1.164.3.2.3.2.3.2.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
INT prtExPhPlDlciPrtIdx1.3.6.1.4.1.164.3.2.3.2.3.2.1.3INTEGERread-onlyThis attribute indicates a unique internal port number. PH.1/E1 and PH.1/T1 cards have three internal ports. Stand-alone units may have six such ports.
I32 prtExPhPlDlciIdx1.3.6.1.4.1.164.3.2.3.2.3.2.1.4Integer32read-onlyThis attribute indicates a unique index for each possible used dlci(16..991). When the protocol is not Multiplexing protocol, its type is 'user' and the only valid index is 1.
INT prtExPhPlDlciValid1.3.6.1.4.1.164.3.2.3.2.3.2.1.5INTEGERread-writeThis attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object
INT prtExPhPlDlciIConSlt1.3.6.1.4.1.164.3.2.3.2.3.2.1.6INTEGERread-writeThis attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. cl - will represent any of the CL slots. This value can be selected for multiple DLCIs of the product. In the ?004 Unit the entries io6(10)..io16) are not valid
INT prtExPhPlDlciIConPrt1.3.6.1.4.1.164.3.2.3.2.3.2.1.7INTEGERread-writeThis attribute indicates a unique port id which the dlci is routed to. clNMS - will be used for NMS SNMP messages. It can be any port of the CL card. This value will be selectable only if prtExPhPlDlciIConSlt='cl' or 'notApplicable'.
I32 prtExPhPlDlciIConDlci1.3.6.1.4.1.164.3.2.3.2.3.2.1.8Integer32read-writeThis attribute indicates a unique internal connection dlci number, the dlci is routed to.
INT prtExPhPlDlciTxBc1.3.6.1.4.1.164.3.2.3.2.3.2.1.9INTEGERread-writeThis attribute indicates a unique Tx committed bandwidth on the user transmit line (or at the port receive line).
INT prtExPhPlDlciTxBe1.3.6.1.4.1.164.3.2.3.2.3.2.1.10INTEGERread-writeThis attribute indicates a unique Tx excess bandwidth on the user transmit line (or at the port receive line).
INT prtExPhPlDlciRxBc1.3.6.1.4.1.164.3.2.3.2.3.2.1.11INTEGERread-writeThis attribute indicates a unique Rx committed bandwidth on the user receive line (or at the port transmit line).
INT prtExPhPlDlciRxBe1.3.6.1.4.1.164.3.2.3.2.3.2.1.12INTEGERread-writeThis attribute indicates a unique Rx excess bandwidth on the user receive line (or at the port transmit line).
I32 prtExPhPlDlciPriority1.3.6.1.4.1.164.3.2.3.2.3.2.1.13Integer32read-writeThis attribute indicates a unique priority of the pcv. 1 is the lowest priority and 8 is the highest priority.
INT prtExPhPlDlciStatus1.3.6.1.4.1.164.3.2.3.2.3.2.1.14INTEGERread-onlyThis attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
prtExPhPlModemTable1.3.6.1.4.1.164.3.2.3.2.3.3not-accessibleExternal Modem Parameters. The write operation into the Table Objects is valid only for the TmpCnfg entry.
prtExPhPlModemEntry1.3.6.1.4.1.164.3.2.3.2.3.3.1not-accessibleAn entry in table.
I32 prtExPhPlModemCnfgIdx1.3.6.1.4.1.164.3.2.3.2.3.3.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtExPhPlModemSltIdx1.3.6.1.4.1.164.3.2.3.2.3.3.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid
INT prtExPhPlModemPrtIdx1.3.6.1.4.1.164.3.2.3.2.3.3.1.3INTEGERread-onlyThis attribute indicates a unique port number. In case of PH.1 card, only exPrt(1) is valid.
INT prtExPhPlModemStatus1.3.6.1.4.1.164.3.2.3.2.3.3.1.4INTEGERread-writeThis object indicates whether a Dial Up Modem is enabled on this port. Default: disable For Vmux devices this object shows whether there is Modem Relay support.
INT prtExPhPlModemActivate1.3.6.1.4.1.164.3.2.3.2.3.3.1.5INTEGERread-writeThis object indicates whether the Dial Up Modem is activated when the first frame is received or it is always activated. Default: onFirstFrame
I32 prtExPhPlModemMaxIdleTime1.3.6.1.4.1.164.3.2.3.2.3.3.1.6Integer32read-writeMax Time allowed in Seconds without any traffic before the line is disconnected. Legal Values are: 1 sec, 2 sec .. 5 sec, 10 sec, 20 sec.. 1 min, 2 min .. 10 min, 15 min, 20 min, 25 min, 30 min. 65535 sec. means that this parameter is not applicable. Default: 1 sec.
I32 prtExPhPlModemTimeBtwnCalls1.3.6.1.4.1.164.3.2.3.2.3.3.1.7Integer32read-writeMinimum Time in Seconds which is required after a call was disconnected. In this time no other call will be initiated from this Modem port even if there were frames transmitted to this port. This time is required for some Modems which have initializations that take a few seconds. Legal Values are: 0 sec. - 30 sec., 1-5 min. 65535 sec. means that this parameter is not applicable. Default: 0 sec
I32 prtExPhPlModemCallDelay1.3.6.1.4.1.164.3.2.3.2.3.3.1.8Integer32read-writeTime in Seconds that the device will wait before dialing to the remote device. This feature is mostly used when there is a backup modem to the main link and the main link is down. In this case it is important to prevent the 2 devices from dialing through the backup modems to each other at the same time. It is advised to configure one side with a small call delay and the other side with a large call delay. Legal Values are: 0 - 30, 60, 120, 180, 240, 300, 600, 900, 1200, 1500, 1800 . 65535 sec. means that this parameter is not applicable. Default: 0 sec
prtLs2Cnfg1.3.6.1.4.1.164.3.2.3.2.4
prtExLs2CnfgTable1.3.6.1.4.1.164.3.2.3.2.4.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExLs2CnfgEntry1.3.6.1.4.1.164.3.2.3.2.4.1.1not-accessibleAn entry in table.
I32 prtExLs2CnfgIdx1.3.6.1.4.1.164.3.2.3.2.4.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtExLs2SltIdx1.3.6.1.4.1.164.3.2.3.2.4.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
INT prtExLs2PrtIdx1.3.6.1.4.1.164.3.2.3.2.4.1.1.3INTEGERread-onlyThis attribute indicates a unique port index. For the Ls2/X.58 exPrt(7)..exPrt(10) are not valid.
INT prtExLs2Connect1.3.6.1.4.1.164.3.2.3.2.4.1.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtExLs2Rate1.3.6.1.4.1.164.3.2.3.2.4.1.1.5INTEGERread-writePort rates.
INT prtExLs2ClkMode1.3.6.1.4.1.164.3.2.3.2.4.1.1.6INTEGERread-writeThis attribute indicates a unique port operation clock mode.
INT prtExLs2Cts1.3.6.1.4.1.164.3.2.3.2.4.1.1.7INTEGERread-writeCTS.
INT prtExLs2Dcd1.3.6.1.4.1.164.3.2.3.2.4.1.1.8INTEGERread-writeDCD.
I32 prtExLs2EnvIdx1.3.6.1.4.1.164.3.2.3.2.4.1.1.9Integer32read-writeEnvelope Index. When prtInLs2EnvAssign=auto, the value is 0 (not applicable).
prtInLs2CnfgTable1.3.6.1.4.1.164.3.2.3.2.4.2not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtInLs2CnfgEntry1.3.6.1.4.1.164.3.2.3.2.4.2.1not-accessibleAn entry in table.
I32 prtInLs2CnfgIdx1.3.6.1.4.1.164.3.2.3.2.4.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtInLs2SltIdx1.3.6.1.4.1.164.3.2.3.2.4.2.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
INT prtInLs2PrtIdx1.3.6.1.4.1.164.3.2.3.2.4.2.1.3INTEGERread-onlyThis attribute indicates a unique internal port index.
INT prtInLs2Connect1.3.6.1.4.1.164.3.2.3.2.4.2.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the module considerations because the module has only one Internal interface which is the composite channel.
I32 prtInLs2Group1.3.6.1.4.1.164.3.2.3.2.4.2.1.5Integer32read-writeThis attribute indicates the group number of the port. LS-2 internal ports with the same group number share the same Time slot of the main link
I32 prtInLs2Member1.3.6.1.4.1.164.3.2.3.2.4.2.1.6Integer32read-writeThis attribute indicates the group member id of the port. This parameter is for the automatic envelope assignment algorithm.
INT prtInLs2LinkTo1.3.6.1.4.1.164.3.2.3.2.4.2.1.7INTEGERread-writeIt indicates the slot of the main link card to which the LS2 card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
INT prtInLs2EnvAssign1.3.6.1.4.1.164.3.2.3.2.4.2.1.8INTEGERread-writeEnvelope assignment type.
prtVc2CnfgTable1.3.6.1.4.1.164.3.2.3.2.5not-accessible- For products supporting more than one configuration, the write operation into the Table is valid only to the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table will be to prtVc2CnfgIdx=1.
prtVc2CnfgEntry1.3.6.1.4.1.164.3.2.3.2.5.1not-accessibleAn entry in table.
I32 prtVc2CnfgIdx1.3.6.1.4.1.164.3.2.3.2.5.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtVc2SltIdx1.3.6.1.4.1.164.3.2.3.2.5.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. For Stand Alone products like WR: notApplicable (255)
I32 prtVc2PrtIdx1.3.6.1.4.1.164.3.2.3.2.5.1.3Integer32read-onlyA unique identifier of the port, within the card. For MP-2100/2200 card ports, Web Ranger and FCD-IP Voice ports the values will be: exPrt1 (1) exPrt2 (2) exPrt3 (3) exPrt4 (4) exPrt5 (5) exPrt6 (6) exPrt7 (7) exPrt8 (8) exPrt9 (9) exPrt10 (10) exPrt11 (11) exPrt12 (12) exPrt13 (13) exPrt14 (14) exPrt15 (15) exPrt16 (16) For LA-240: The index for fixed voice ports will be - exPrt6 (6) exPrt7 (7) exPrt8 (8) exPrt9 (9) The index for voice card ports will be - Slot number * 100 + ch (for IO-1: 101..104, for IO-2: 201..204). For other products' index see their specification.
INT prtExVc2Connect1.3.6.1.4.1.164.3.2.3.2.5.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
I32 prtExVc2TransGain1.3.6.1.4.1.164.3.2.3.2.5.1.5Integer32read-writeTransmit gain in dBm. For ports of MP-104/204, MP-2100/2200 VC-6A, VC-6AG, VC-8 VC-4/Omni and VC-16 cards, the units will be 0.1dBm because valid values can be in 0.5dBm steps.
I32 prtExVc2ReceiveGain1.3.6.1.4.1.164.3.2.3.2.5.1.6Integer32read-writeReceive gain in dBm. For ports of MP-104/204, MP-2100/2200 VC-6A, VC-6AG, VC-8 VC-4/Omni and VC-16 cards, the units will be 0.1dBm because valid values can be in 0.5dBm steps.
INT prtExVc2Wire1.3.6.1.4.1.164.3.2.3.2.5.1.7INTEGERread-writeFor some cards, this object is equal for all the ports in the specific card because of HW limitations. For FXO & FXS this parameter is not applicable.
INT prtExVc2CodingLaw1.3.6.1.4.1.164.3.2.3.2.5.1.8INTEGERread-writeThis attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links. This object is equal for all the ports in the specific module because of HW limitations
INT prtExVc2Sig1.3.6.1.4.1.164.3.2.3.2.5.1.9INTEGERread-writeThis attribute indicates the method for decoding/encoding the signaling information(on/off hook). noSignaling (1) - not using signaling (only voice). robbedBitMultiFrame(2) - is the standard method for T1 links and proprietary method for E1 links. chAssociatedE1 (3) - is valid only for E1 G.732S links. robbedBitFrame (4) - is proprietary method implimenting 7 bit for the voice and 1 bit dedicated for signaling. For some cards, this object is equal for all the ports in the specific module because of HW limitations.
INT prtExVc2Oos1.3.6.1.4.1.164.3.2.3.2.5.1.10INTEGERread-writeThis object is equal for all the ports in the specific card because of HW limitations
INT prtExVc2LinkTo1.3.6.1.4.1.164.3.2.3.2.5.1.11INTEGERread-writeThis attribute indicates the slot of the ML card to which the VC card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
INT prtExVc2OperMode1.3.6.1.4.1.164.3.2.3.2.5.1.12INTEGERread-writeThis object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request.
INT prtExVc2SigProfile1.3.6.1.4.1.164.3.2.3.2.5.1.13INTEGERread-writeThis object indicates the Signaling Profile of the port. notApplicable - for VC-2 family and when prtExVc2Sig=noSignaling(1) p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4
INT prtExVc2CallEnable1.3.6.1.4.1.164.3.2.3.2.5.1.14INTEGERread-writeThis object indicates the Enabled Call direction. notApplicable - for all cards except VC-2/R2. both - incoming + outgoing.
INT prtExVc2R2Delay1.3.6.1.4.1.164.3.2.3.2.5.1.15INTEGERread-writeThis object indicates the R2 Delay. notApplicable - for all cards except VC-2/R2.
INT prtExVc2CasStd1.3.6.1.4.1.164.3.2.3.2.5.1.16INTEGERread-writeThis object indicates the CAS (Channel Associated Signaling) Standard. notApplicable - for all cards except VC-2/R2.
INT prtExVc2EchoCanceler1.3.6.1.4.1.164.3.2.3.2.5.1.17INTEGERread-writeEcho canceler activation. notApplicable - for VC-2 and VC-6 cards.
INT prtExVc2IfType1.3.6.1.4.1.164.3.2.3.2.5.1.18INTEGERread-writeInterface Type.
INT prtExVc2Encoding1.3.6.1.4.1.164.3.2.3.2.5.1.19INTEGERread-writeVoice Encoding Mode. linear - is relevant only for the ports of VC-16A card.
OCT prtExVc2TxBitCode1.3.6.1.4.1.164.3.2.3.2.5.1.20OCTET STRINGread-write- - - For MP & FCD - - - This object represents 4 parameters, by 2 Octets : Tx D Bit Code-MSB nibble, Tx C Bit Code- nibble, Tx B Bit Code- nibble, Tx A Bit Code-LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = M lead 2 hex = 0010 = M lead inverse 3 hex = 0011 = Reverse Polarity 4 hex = 0100 = Metering Pulse 5 hex = 0101 = Forced 1 6 hex = 0110 = Forced 0 7-F hex - not used (invalid values) This object will be RO if prtExVc2SigProfile is NOT manual. - - - For WR II - - - This object represents the following 4 parameters by 2 Octets: 1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1). 2. Default signaling bits that are not in use (nibble 2). 3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3). 4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4). Each nibble: --------------------------------------------------------------------------------------- Value On/Off Hook Default sig. Ring Detect. M (Mouth) --------------------------------------------------------------------------------------- 0 hex = 0000 Not Applicable Not Applicable. Not Applicable Not Applicable 1 hex = 0001 Tx A bit Values 1-3 are Tx A bit Tx A bit 2 hex = 0010 Tx A bit inverse for On/Off Hook Tx A bit inv. Tx A bit inv. 3 hex = 0011 Tx B bit A,B,A Inv,B Inv. Tx B bit Tx B bit 4 hex = 0100 Tx B bit inverse Values 4-7 are Tx B bit inv. Tx B bit inv. 5 hex = 0101 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid 6 hex = 0110 not Used-invalid A, A Inverse. not Used-invalid not Used-invalid 7 hex = 0111 not Used-invalid not Used-invalid not Used-invalid 8 hex = 1000 not Used-invalid Values 8-11 are not Used-invalid not Used-invalid 9 hex = 1001 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid A hex = 1010 not used-invalid B, B Inverse. not Used-invalid not Used-invalid B hex = 1011 not used-invalid The Bits order: not Used-invalid not Used-invalid C-F hex not used-invalid ABCD not Used-invalid not Used-invalid Default value: 11 11
OCT prtExVc2RxBitOutput1.3.6.1.4.1.164.3.2.3.2.5.1.21OCTET STRINGread-write- - - For MP (VC-Q card only) & FCD - - - This object represents 3 parameters by 2 Octets: Spare -MSB nibble, always=0 hex E Lead Output - nibble, Reverse Polarity Output- nibble, Metering Pulse Output -LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = Rx A bit 2 hex = 0010 = Rx A bit inverse 3 hex = 0011 = Rx B bit 4 hex = 0100 = Rx B bit inverse 5 hex = 0101 = Rx C bit 6 hex = 0110 = Rx C bit inverse 7 hex = 0111 = Rx D bit 8 hex = 1000 = Rx D bit inverse 9 hex = 1001 = none A-F hex - not used (invalid values) This object will be RO if prtExVc2SigProfile is NOT manual. - - - For MP (VC-8, VC-16, VC-16A cards) - - - This object represents 4 parameters, by 2 Octets : Tx D Bit Code-MSB nibble, Tx C Bit Code- nibble, Tx B Bit Code- nibble, Tx A Bit Code-LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = not used (invalid value) 2 hex = 0010 = not used (invalid value) 3 hex = 0011 = not used (invalid value) 4 hex = 0100 = not used (invalid value) 5 hex = 0101 = Forced 1 6 hex = 0110 = Forced 0 7-F hex - not used (invalid values) This object will be RO. - - - For WR II - - - This object represents the following 2 parameters in 1 Octet: 1. On/Off hook signaling receive mode from the T1/E1 into the FXS/FXO (MSB nibble 1). 2. E (Ear) Signaling receive mode from the T1/E1 into the E&M (LSB nibble 2). Each nibble: --------------------------------------------------------------------------------------- Value On/Off Hook E (Ear) --------------------------------------------------------------------------------------- 0 hex = 0000 Not Applicable Not Applicable 1 hex = 0001 Rx A bit Rx A bit 2 hex = 0010 Rx A bit inverse Rx A bit inverse 3 hex = 0011 Rx B bit Rx B bit 4 hex = 0100 Rx B bit inverse Rx B bit inverse 5-F hex not used-invalid not Used-invalid Default value: 11
INT prtExVc2MeterRate1.3.6.1.4.1.164.3.2.3.2.5.1.22INTEGERread-writeThis entry is applicable only for VC-6A/FXO, VC-6A/FXS, VC-8/FXO, VC-8/FXS, VC-16/FXO and VC-16/FXS. Meter Rate means rate of Call Meter in Public Phones, in KHz units. For some cards, the value must be the same for all card's ports.
INT prtExVc2IfSignaling1.3.6.1.4.1.164.3.2.3.2.5.1.23INTEGERread-writeThis entry is applicable only for VC-6A, VC-6AG, VC-8/FXO, VC-8/FXS, VC-16/FXO and VC-16/FXS cards. Interface Analog Signaling. Must be the same for all card's ports. loopStart - for the usual trunk/phone types. groundStart - for trunks that need Ground signaling . winkStart - for trunks that need Reverse Polarity.
INT prtExVc2SeizeAck1.3.6.1.4.1.164.3.2.3.2.5.1.24INTEGERread-writeThis parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal. Default value for WR FXO: no(2).
INT prtExVc2EandMType1.3.6.1.4.1.164.3.2.3.2.5.1.25INTEGERread-writeThis is the signaling type on the E&M analog side. The analog signaling includes voltage, no. of pins and other parameters.
INT prtExVc2RemType1.3.6.1.4.1.164.3.2.3.2.5.1.26INTEGERread-writeRemote Type. Applicable for VC-6A/4LB card & for IPMUX-1E Far End Type - E1,T1(T1-ESF) or T1-D4 .
INT prtExVc2ConvTime1.3.6.1.4.1.164.3.2.3.2.5.1.27INTEGERread-writeConversation Time in minutes. Applicable for VC-6A/4LB card.
INT prtExVc2SigFeedback1.3.6.1.4.1.164.3.2.3.2.5.1.28INTEGERread-writeSignaling Feedback. Applicable for VC-8/FXO and VC-16/FXO cards.
INT prtExVc2EchoCancelerModule1.3.6.1.4.1.164.3.2.3.2.5.1.29INTEGERread-onlyThis parameter indicates whether Echo canceler module exists for this port.
INT prtExVc2ReversePolarity1.3.6.1.4.1.164.3.2.3.2.5.1.30INTEGERread-writeThis object Enables/Disables Reverse Polarity for this port.
INT prtExVc2RingerFrequency1.3.6.1.4.1.164.3.2.3.2.5.1.31INTEGERread-writeThis object selects the Ringer Frequency (Hz) for this port.
INT prtExVc2SigService1.3.6.1.4.1.164.3.2.3.2.5.1.32INTEGERread-writeSignaling Service. advanced - is relevant only for ports of VC-8, VC-16 FXS cards. It is used for Signaling Services of V5.1 or R2.
INT prtExVc2CallerIdEnable1.3.6.1.4.1.164.3.2.3.2.5.1.33INTEGERread-writeThis object Enables/Disables Receiving the Caller Id number from the remote side, for this port/channel.
INT prtExVc2CompressMethod1.3.6.1.4.1.164.3.2.3.2.5.1.34INTEGERread-writeThis object is applicable only when prtExVc2Encoding=adpcm. It defines which method is used for Compression. g726 - for 4 bits (the standard method). g726 - for 3 bits. It is especially needed for T1 applications with signaling.
INT prtExVc2ObMode1.3.6.1.4.1.164.3.2.3.2.5.1.35INTEGERread-writeThis object defines the Net operation mode of the Omni-Bus card's port. pointToPoint - only 2 end-point ports talk; like any other voice card omniBus - many talk and listen. Like conference call. All can listen to all. pointToMultiPointSrc - There is one Master who can be heard by all. All can talk, but only the Master can hear all. Others can hear only the Master. This port is of the Master (Src). pointToMultiPointDst - There is one Master who can be heard by all. All can talk, but only the Master can hear all. Others can hear only the Master. This port is of a Destination (NOT Master).
INT prtExVc2VAD1.3.6.1.4.1.164.3.2.3.2.5.1.36INTEGERread-writeThis object defines whether Voice Activation Detector (VAD) will be On or Off. off - will be usually selected when a Modem is connected to the port; not a phone. notApplicable - when prtExVc2DspMode=pointToPoint.
INT prtExVc2NoiseLevelForVAD1.3.6.1.4.1.164.3.2.3.2.5.1.37INTEGERread-writeThis object defines the Level of Noise on the line, the Voice Activation Detector (VAD) will have to deal with. notApplicable - when prtExVc2VAD=off.
INT prtExVc2WesternSigMode1.3.6.1.4.1.164.3.2.3.2.5.1.38INTEGERread-writeThis object defines the Western Signaling Mode. detector - detects signal and passes it as is. generator - generates the signal. notApplicable - when Western HW is not installed.
INT prtExVc2BusProtectionPoint1.3.6.1.4.1.164.3.2.3.2.5.1.39INTEGERread-writeThis object defines if the port is Bus Protection Point or not. notApplicable - when prtExVc2DspMode=pointToPoint. When we have a chain of devices where the edge devices ports are the Bus Protection Point, user must configure one of these ports as 'first' and the other as 'last'. It does not matter which one, it just matters that they will be different.
INT prtExVc2ImpedanceStandard1.3.6.1.4.1.164.3.2.3.2.5.1.40INTEGERread-writeThis object defines the Standard used for Impedance. -G.712 - 600 Ohm - used in USA and other countries. -Q552/ETSI - used in some countries in Europe -Q522/Italy - used in Italy.
prtHsfCnfgTable1.3.6.1.4.1.164.3.2.3.2.6not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtHsfCnfgEntry1.3.6.1.4.1.164.3.2.3.2.6.1not-accessibleAn entry in table.
I32 prtHsfCnfgIdx1.3.6.1.4.1.164.3.2.3.2.6.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relate to the TmpCnfg.
INT prtHsfSltIdx1.3.6.1.4.1.164.3.2.3.2.6.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
INT prtHsfPrtIdx1.3.6.1.4.1.164.3.2.3.2.6.1.3INTEGERread-onlyThis attribute indicates a unique external port index. Hs2 has only two ports (exPrt1,exPrt2). Hs3 has three ports (exPrt1,exPrt2,exPrt3). Hsq and hsqN has four ports. Hs6 has six external ports. Hs12 has twelve external ports. inPrt1, inPrt2 - are relevant for VID card.
INT prtExHsfConnect1.3.6.1.4.1.164.3.2.3.2.6.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtExHsfRate1.3.6.1.4.1.164.3.2.3.2.6.1.5INTEGERread-writeThis attribute indicates the port speed.
INT prtExHsfClkMode1.3.6.1.4.1.164.3.2.3.2.6.1.6INTEGERread-writeThis attribute indicates a unique port operation clock mode.
INT prtExHsfCts1.3.6.1.4.1.164.3.2.3.2.6.1.7INTEGERread-writeThis attribute indicates a unique CTS control line operation mode.
INT prtExHsfFifoSize1.3.6.1.4.1.164.3.2.3.2.6.1.8INTEGERread-writeSize in bits.
INT prtExHsfLinkTo1.3.6.1.4.1.164.3.2.3.2.6.1.9INTEGERread-writeThis attribute indicates a slot of Main Link module, that the port is linked to. This object is the same for all the ports in the specific card because of HW limitations. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
INT prtExHsfOperMode1.3.6.1.4.1.164.3.2.3.2.6.1.10INTEGERread-writeThis object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request. bidirBcastRing = Bidirectional Broadcast Ring. When this value is selected, AND RTS=On, the port opens its transmission channel.
INT prtExHsfInbandLoopback1.3.6.1.4.1.164.3.2.3.2.6.1.11INTEGERread-writeThis object indicates if Inband Loopback from the Network should be enabled or disabled.
INT prtExHsfClkPolarity1.3.6.1.4.1.164.3.2.3.2.6.1.12INTEGERread-writeThis object indicates the clock polarity. For FCD-M this object will be applicable only for the fixed HS port (the fixed port on the device).
INT prtExHsfControlSignal1.3.6.1.4.1.164.3.2.3.2.6.1.13INTEGERread-writeThis object indicates the Control Signal according to G.797 ITU-T standard. For FCD-M this object will be applicable for the fixed HS port (the fixed port on the device) and HS-Q/N channels. Local and End to End are applicable only when channel Interface type is RS-530, else it will be Not Applicable.
INT prtExHsfBcastRingSrcPort1.3.6.1.4.1.164.3.2.3.2.6.1.14INTEGERread-writeThis object is applicable only when prtExHsfOperMode= bidirBcastRing. In this case, the values mean: - none - this port will be connected to ML in TSA as usual. - exPrt1.. exPrtX ; X=maximum ports of the card in focus : it means that the same TS that is assigned in TSA to this port is actually connected also to this port, for Broadcast Ring mode. Therefore, this port should NOT be connected to ML in TSA.
prtHs4Cnfg1.3.6.1.4.1.164.3.2.3.2.7
prtExHs4CnfgTable1.3.6.1.4.1.164.3.2.3.2.7.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExHs4CnfgEntry1.3.6.1.4.1.164.3.2.3.2.7.1.1not-accessibleAn entry in table.
I32 prtExHs4CnfgIdx1.3.6.1.4.1.164.3.2.3.2.7.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtExHs4SltIdx1.3.6.1.4.1.164.3.2.3.2.7.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted.
INT prtExHs4PrtIdx1.3.6.1.4.1.164.3.2.3.2.7.1.1.3INTEGERread-onlyA unique identifier of the port, within the card.
INT prtExHs4Connect1.3.6.1.4.1.164.3.2.3.2.7.1.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithm. It also affects all the module considerations because the card has only one external (physical) interface.
INT prtExHs4LineType1.3.6.1.4.1.164.3.2.3.2.7.1.1.5INTEGERread-writeThis attribute is the line type parameter for T1/E1 interface. The user should select only the parameters relevant to the specific card: T1 line code parameters for the HS-4/1 and E1 line code parameters for the HS-4/2. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) dsx1ESF (2) dsx1D4 (3) dsx1E1 (4) dsx1E1-CRC (5) dsx1E1-MF (6) dsx1E1-MF-CRC (7)
INT prtExHs4LineCode1.3.6.1.4.1.164.3.2.3.2.7.1.1.6INTEGERread-writeThis attribute is the line code parameter used for T1/E1 interface. The user should select only the parameters relevant to the specific card: T1 line code parameters for the MPH.1/T1 and E1 line code parameters for the MPH.1/E1. This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)
INT prtExHs4LineLen1.3.6.1.4.1.164.3.2.3.2.7.1.1.7INTEGERread-writeThis attribute is the line length parameter used only for T1 interfaces. len399p533ft=len-399-533ft
INT prtExHs4RestoreT1.3.6.1.4.1.164.3.2.3.2.7.1.1.8INTEGERread-writeTime passing from the disappearance of the loss of synchronization condition (red alarm), to the restoration of normal service.
INT prtExHs4OosSig1.3.6.1.4.1.164.3.2.3.2.7.1.1.9INTEGERread-writeOut of Service signal type.
INT prtExHs4OosCode1.3.6.1.4.1.164.3.2.3.2.7.1.1.10INTEGERread-writeOOS Code
I32 prtExHs4IdleCode1.3.6.1.4.1.164.3.2.3.2.7.1.1.11Integer32read-writeType value(00 - FF HEX), excluding 0H,8H,10H,12H,21H,24H, 42H,49H,84H,92H
INT prtExHs4MfClkSrcSlt1.3.6.1.4.1.164.3.2.3.2.7.1.1.12INTEGERread-writeThis attribute indicates whether the port Tx is multiframe synchronized with Rx multiframe of another port and the slot position of that port. This opration is required in order to bypass signaling of PCM voice channels. When its value is Local(2) there is no meaning to 'prtExHs4MfClkSrcPrt' parameter. In the ?004 Unit the entries io6(10)..io16) are not valid
INT prtExHs4MfClkSrcPrt1.3.6.1.4.1.164.3.2.3.2.7.1.1.13INTEGERread-writeA unique number to identify a port position in the mux if the MultiFrame clock source is valid (YES). inPrt1 - for MTML-H/E1 cards.
prtExHs4TsCnfgTable1.3.6.1.4.1.164.3.2.3.2.7.2not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExHs4TsEntry1.3.6.1.4.1.164.3.2.3.2.7.2.1not-accessibleAn entry in table.
I32 prtExHs4TsCnfgIdx1.3.6.1.4.1.164.3.2.3.2.7.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtExHs4TsSltIdx1.3.6.1.4.1.164.3.2.3.2.7.2.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
INT prtExHs4TsPrtIdx1.3.6.1.4.1.164.3.2.3.2.7.2.1.3INTEGERread-onlyThis attribute indicates a unique port number. Hs4/T1 and Hs4/T1 cards have only one external interface.
I32 prtExHs4TsIdx1.3.6.1.4.1.164.3.2.3.2.7.2.1.4Integer32read-onlyThis attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines, time slot 16 is not valid for data, it is dedicated to multiframe synchronization bits and voice signaling.
INT prtExHs4TsIConSlot1.3.6.1.4.1.164.3.2.3.2.7.2.1.5INTEGERread-writeThis attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io16) are not valid. split - will be used when the Src TS is connected to more than one slot OR more than one port (each needing less than a whole TS).
INT prtExHs4TsIConPrt1.3.6.1.4.1.164.3.2.3.2.7.2.1.6INTEGERread-writeThis attribute indicates the internally (In Mux) connected/routed port.
I32 prtExHs4TsIConTs1.3.6.1.4.1.164.3.2.3.2.7.2.1.7Integer32read-writeThis attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Module and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling.
prtHsiCnfg1.3.6.1.4.1.164.3.2.3.2.8
prtExHsiCnfgTable1.3.6.1.4.1.164.3.2.3.2.8.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExHsiCnfgEntry1.3.6.1.4.1.164.3.2.3.2.8.1.1not-accessibleAn entry in table.
I32 prtExHsiCnfgIdx1.3.6.1.4.1.164.3.2.3.2.8.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtExHsiSltIdx1.3.6.1.4.1.164.3.2.3.2.8.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted.
I32 prtExHsiPrtIdx1.3.6.1.4.1.164.3.2.3.2.8.1.1.3Integer32read-onlyA unique port identifier within the card. For MP : 1..12 For DXC: 111 .. 2531. See DXC R6 spec for port index convention. For FCD-A, 'S' Interface external ports: 131, 141, 151, 161.
INT prtExHsiConnect1.3.6.1.4.1.164.3.2.3.2.8.1.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms. v51 - this port is connected to a V5.1 interface. All rest of the values will be 'notApplicable' in this case. V5 MIB will be used instead. v52 - this port is connected to a V5.2 interface. All rest of the values will be 'notApplicable' in this case. V5 MIB will be used instead.
INT prtExHsiRate1.3.6.1.4.1.164.3.2.3.2.8.1.1.5INTEGERread-writeThis attribute indicates the port speed.
INT prtExHsiLinkTo1.3.6.1.4.1.164.3.2.3.2.8.1.1.6INTEGERread-writeIt indicates the slot of the main link card to which the HS-? card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
INT prtExHsiInterface1.3.6.1.4.1.164.3.2.3.2.8.1.1.7INTEGERread-writeIt indicates the interface type: lt = line termination nt = network termination te = terminal equipment. lt1 - for ASMi-31 connection (not ISDN) For MP: For HS-U/I only 'lt' and 'nt' are applicable. For HS-U/1 only 'lt' is applicable. For HS-S , only 'te' and 'nt' are applicable. For HS-U, this object is not applicable. For HS-U6, HS-U12, are applicable: 'lt'=lt-i,'nt'=nt-i, lt1. For DXC: For HS-U8, HS-U16, are applicable: 'lt'=LT-I,'nt'=NT-I, 'lt1'=LT-1.
INT prtExHsiActType1.3.6.1.4.1.164.3.2.3.2.8.1.1.8INTEGERread-writeIt indicates the Activation Type. Activation Type is the Synchronization type towards the PBX. It is applicable only when prtExHsiInterface=nt. notApplicable - for cards that do not support this object, or when prtExHsiInterface is NOT nt.
prtInHsiCnfgTable1.3.6.1.4.1.164.3.2.3.2.8.2not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry. This table is not applicable for MP-2100 HS-U card type.
prtInHsiCnfgEntry1.3.6.1.4.1.164.3.2.3.2.8.2.1not-accessibleAn entry in table.
I32 prtInHsiCnfgIdx1.3.6.1.4.1.164.3.2.3.2.8.2.1.1Integer32read-onlyThis object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtInHsiSltIdx1.3.6.1.4.1.164.3.2.3.2.8.2.1.2INTEGERread-onlyThis object indicates a unique slot position where the card is inserted.
I32 prtInHsiPrtIdx1.3.6.1.4.1.164.3.2.3.2.8.2.1.3Integer32read-onlyA unique port identifier within the card. Valid values for MP: inPrt1 (101) .. inPrt48 (148). Valid values for DXC: 11012.. 25316. See DXC R6 spec for port index convention.
INT prtInHsiConnect1.3.6.1.4.1.164.3.2.3.2.8.2.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtInHsiRate1.3.6.1.4.1.164.3.2.3.2.8.2.1.5INTEGERread-writeThis object indicates the port speed. For HS-U/I and HS-S ports: 2 bit - up to 9600bps 4 bit - 19200bps 8 bit - 38400bps .. 64kbps. concentrated - this D channel goes to a Concentration channel, that represents many channels that this value was selected for them. The Concentrated channel is an Internal D Channel of the same card. This value is applicable only for D channels, except Concentration channel itself. --for HS-S and HS-U/I cards the Concentration channel will always be: internal-13 --for MP-2200 HS-S12, HS-S6, HS-U12, HS-U6 and DXC HS-U8 and HS-U16 cards, the Concentration channel is selected via the prtInHsiConcentratedTo object. notConnected - same as prtInHsiConnect=no.
I32 prtInHsiConcentratedTo1.3.6.1.4.1.164.3.2.3.2.8.2.1.6Integer32read-writeThe Concentration D Channel of the prtInHsiPrtIdx port. The port always belongs to the same card as prtInHsiPrtIdx port. This object is applicable only when prtInHsiRate=concentrated. Valid values: - notApplicable: 255 - for MP-2200: HS-S12, HS-U12 cards: inPrt37 (137) .. inPrt48 (148). HS-S6, HS-U6 cards: inPrt19 (119) .. inPrt24 (124). - for DXC: HS-U8 cards: 112 .. 254 HS-U16 cards: 112 .. 258. See DXC R6 spec for port index convention.
prtPVc4Cnfg1.3.6.1.4.1.164.3.2.3.2.9
prtExPVc4CnfgTable1.3.6.1.4.1.164.3.2.3.2.9.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExPVc4CnfgEntry1.3.6.1.4.1.164.3.2.3.2.9.1.1not-accessibleAn entry in table.
I32 prtExPVc4CnfgIdx1.3.6.1.4.1.164.3.2.3.2.9.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtExPVc4SltIdx1.3.6.1.4.1.164.3.2.3.2.9.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted.
INT prtExPVc4PrtIdx1.3.6.1.4.1.164.3.2.3.2.9.1.1.3INTEGERread-onlyThis object indicates the port number in the selected card (slot).
INT prtExPVc4PrtType1.3.6.1.4.1.164.3.2.3.2.9.1.1.4INTEGERread-writeThis object indicates the type of the selected port. In Mx 30/300 phase 4: s0 & u are for Voice over ISDN. In MX 30/300 phase 5: sQsig & uQsig are used for Voice over ISDN with Qsig option. In MX MVC4 voice cards, each pair of ports 1-2, 3-4 may have a different type: E&M, FXO, FXS. In MVC4 compressed voice cards ports 1..4 have the same interface for all ports. In MVC8 compressed voice cards each group of ports 1..4, 5..8 may have a different type: E&M, FXO, FXS.
INT prtExPVc4Connect1.3.6.1.4.1.164.3.2.3.2.9.1.1.5INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtExPVc4IfType1.3.6.1.4.1.164.3.2.3.2.9.1.1.6INTEGERread-writeThis attribute indicates the interface type of the port. eAndM4wires and eAndM2wires - are valid only for E&M port type eAndM4wires - means 2/4 wires fxoGnd and fxoLoop - are valid only for FXO port type fxsGnd and fxsLoop - are valid only for FXS port type e1Framer, e1Slave, t1Framer, t1Slave - are applicable for the mvc4Pbx cards only.
I32 prtExPVc4TxGain1.3.6.1.4.1.164.3.2.3.2.9.1.1.7Integer32read-writeTransmission gain in dB.
I32 prtExPVc4RxGain1.3.6.1.4.1.164.3.2.3.2.9.1.1.8Integer32read-writeReception gain in dBm.
INT prtExPVc4MaxRate1.3.6.1.4.1.164.3.2.3.2.9.1.1.9INTEGERread-writeVoice rate.
INT prtExPVc4Tc1.3.6.1.4.1.164.3.2.3.2.9.1.1.10INTEGERread-writeTime interval for CIR control, in seconds. The value will be the same for all cards' ports.
INT prtExPVc4Oos1.3.6.1.4.1.164.3.2.3.2.9.1.1.11INTEGERread-writeHandling type, when connection is lost.
INT prtExPVc4EchoCanceler1.3.6.1.4.1.164.3.2.3.2.9.1.1.12INTEGERread-writeEcho canceler activation.
I32 prtExPVc4VarDelay1.3.6.1.4.1.164.3.2.3.2.9.1.1.13Integer32read-writeMaximum variant delay of the FR network, in msec.
I32 prtExPVc4CongLevel1.3.6.1.4.1.164.3.2.3.2.9.1.1.14Integer32read-writeThis object indicates the level of delayed data in precents of total available dynamic memory, for which the port will start to operate as congested. The resolution of the parameter is 5%.
INT prtExPVc4Wire1.3.6.1.4.1.164.3.2.3.2.9.1.1.15INTEGERread-writeThis object indicates the wiring of the E&M port. It is applicable only for E&M card type.
INT prtExPVc4ExtensionType1.3.6.1.4.1.164.3.2.3.2.9.1.1.16INTEGERread-writeThis object indicates the type of extension relevant for this port. ipForceConnect (6) is used for automatic connection or automatic dialing when the phone is off hook (hot line). permanentDial (7) means that the call is established upon power up. The hook may be on or off. Permanent Dialing can be used when there is no signaling. autoAccept (8) means that the called party in the Permanent Dialing will accept the call from the remote side automatically upon on or off hook.
STR prtExPVc4ExtensionNumber1.3.6.1.4.1.164.3.2.3.2.9.1.1.17DisplayStringread-writeThis is the extension number of this port. This field is relevant only when the extension type is voice switching and is read only if the port is member of a hunt group.
INT prtExPVc4OutPulsing1.3.6.1.4.1.164.3.2.3.2.9.1.1.18INTEGERread-writeThis field indicates whether to outpulse the received digits. It is notApplicable(1) when the extension type is forceConnect(2).
INT prtExPVc4HuntGroupMb1.3.6.1.4.1.164.3.2.3.2.9.1.1.19INTEGERread-writeThis object indicates if this port belongs to an hunt group.
I32 prtExPVc4HuntGroupIdx1.3.6.1.4.1.164.3.2.3.2.9.1.1.20Integer32read-writeIf it belongs to an hunt group, this fields indicates the index of the relevant hunt group. 0 = notApplicable
INT prtExPVc4AutoFaxMode1.3.6.1.4.1.164.3.2.3.2.9.1.1.21INTEGERread-writeThis object indicates if the system will switch automatically to FAX mode when detecting FAX activity. Default=Yes.
INT prtExPVc4FaxRate1.3.6.1.4.1.164.3.2.3.2.9.1.1.22INTEGERread-writeFAX initial rate. Default=9600 bps.
INT prtExPVc4SeizeAck1.3.6.1.4.1.164.3.2.3.2.9.1.1.23INTEGERread-writeThis parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal. Example: If Seize Ack Parameter = YES, when the MVC.4 receives a seize signal (Off Hook) from the PBX it will send an Off Hook to the PBX. The Seize Parameter is relevant for all the following cards: MVC-4 MVC-4/E1-Framer MVC-4/T1-DSU-Framer MVC-4/T1-CSU-Framer MVC-4/E1-SLAVE MVC-4/T1-SLAVE Default values: Analog FXS - No (value can't be changed). Analog FXO - Yes (value can't be changed). Analog E&M - No (values NO/YES). Digital E1/T1 Framer & Slave - No.
INT prtExPVc4SignalingProtocol1.3.6.1.4.1.164.3.2.3.2.9.1.1.24INTEGERread-writeThe signaling protocol that will be used between the PABX & the voice port. Delay Start Protocol: the line is seized by sending an Off hook signal and after a delay, if the called party is available (On hook) DTMF (Dual Tone Multi Frequency) digits are sent towards the called party. Immediate Start Protocol: the line is seized by sending an Off Hook signal and immediately DTMF digits are sent towards the called party. Wink start protocol: the line is seized by sending an Off Hook signal and then the called party sends a short Off Hook wink signal. Now the calling party starts sending DTMF digits.
I32 prtExPVc4DelayStart1.3.6.1.4.1.164.3.2.3.2.9.1.1.25Integer32read-writeThis parameter is used only for Delay Protocol. This is the time that the calling party will wait after sending an Off hook signal and before sending DTMF digits to the called party. The delay values are 100..5000 msec in intervals of 100 msec.
I32 prtExPVc4WinkMinDuration1.3.6.1.4.1.164.3.2.3.2.9.1.1.26Integer32read-writeThis parameter is used only for Wink Protocol. Min Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec.
I32 prtExPVc4WinkMaxDuration1.3.6.1.4.1.164.3.2.3.2.9.1.1.27Integer32read-writeThis parameter is used only for Wink Protocol. Max Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec.
INT prtExPVc4GenerateTone1.3.6.1.4.1.164.3.2.3.2.9.1.1.28INTEGERread-writeThis parameter indicates whether the device (MX or MPH) should generate dial tones for the channel. If the value is yes (3), it generates dial tones. If the value is no (2), the connected equipment will generate dial tones. For example for some ISDN sets the dial tone is generated by the phone itself while for others sets it is generated by the MX.
INT prtExPVc4CodingLaw1.3.6.1.4.1.164.3.2.3.2.9.1.1.29INTEGERread-writeThis attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links. This object is equal for all the ports in the specific module because of HW limitations
INT prtExPVc4GenerateRingBack1.3.6.1.4.1.164.3.2.3.2.9.1.1.30INTEGERread-writeDetermines whether the Ring Back tone is generated locally or from the remote end. The default is - NO (Meaning coming from the remote end). Yes means that the Ring Back Tone is generated locally. Applicable only for Force Connect.
I32 prtExPVc4ChannelId1.3.6.1.4.1.164.3.2.3.2.9.1.1.31Integer32read-writeChannel Identifier. According to FRF11 each voice port that works as force connect should add a CH Id after the DLCI in the frame header. Default : 1 Applicable only for Force Connect. Not Applicable value will be 0.
INT prtExPVc4PortConnection1.3.6.1.4.1.164.3.2.3.2.9.1.1.32INTEGERread-writePort connection determines whether the port is connected to a PABX (Trunk) or to Telephone set (Line) . It determines whether to send certain messages to the port or not. If the type is LINE then the port generates a ring back tone , if TRUNK it doesn't (The PBX does it).
INT prtExPVc4CoderAndRate1.3.6.1.4.1.164.3.2.3.2.9.1.1.33INTEGERread-writeCoder and Rate for the Voice Compression. In MPH: Relevant for MVC-8 card only.
STR prtExPVc4DestinationNum1.3.6.1.4.1.164.3.2.3.2.9.1.1.34DisplayStringread-writeThe destination phone number: 0 to 22 digits. Applicable for Auto Dial - ipForceConnect(6), Permanent Dial and Auto Accept Extension Types. Default: Null String
INT prtExPVc4DtmfRelay1.3.6.1.4.1.164.3.2.3.2.9.1.1.35INTEGERread-writeWhen DTMF RELAY is disabled, the DTMF digits (dialed by the user) are transmitted as compressed voice and in the remote unit are decompressed. When DTMF RELAY is enabled, the DTMF digits are detected at the near side and not transmitted as voice. Instead, only an indication of what digits were dialed are transmitted and in the far end the tone is regenerated.
I32 prtExPVc4DiscOnSilence1.3.6.1.4.1.164.3.2.3.2.9.1.1.36Integer32read-writeNo. of silenced seconds after which the call will be disconected. A value of 0 means that there will be no disconnect when there is silence. Possible values: 0 - 900 sec.
INT prtExPVc4DynamicJitter1.3.6.1.4.1.164.3.2.3.2.9.1.1.37INTEGERread-writeThe MVC8 uses two mechanisms to overcome the network delay. The first one is a static jitter buffer which holds a constant buffer of up to 300 Msec and can be controled by the JITTER parameter (prtExPVc4VarDelay). The second one is the dynamic jitter which calculates, in real time, the network delay and handles a jitter buffer dynamically. The dynamic mechanism that is implemented in MVC8, was intended to overcome network delay yet when the network bursts, the MVC8 dynamic mechanism is not able to overcome the delay. Therefore it is better not to use the dynamic jitter (DISABLE - should be the default) where bursts may occur often.
INT prtExPVc4EandMType1.3.6.1.4.1.164.3.2.3.2.9.1.1.38INTEGERread-writeThis is the signaling type on the E&M analog side. The analog signaling includes voltage, no. of pins and other parameters.
I32 prtExPVc4Rate1.3.6.1.4.1.164.3.2.3.2.9.1.1.39Integer32read-writeThis is the Rate of the port in TS units. It is used by VF-30 card family. 0 = NA = port is not intended to be connected; therefore, no Rate.
I32 prtExPVc4FrameSize1.3.6.1.4.1.164.3.2.3.2.9.1.1.40Integer32read-writeDefines the maximum size in Bytes of the multiplexed frame. In some cases this must be limited to avoid IP fragmentation, which makes the multiplexing useless, and can also decrease the damage in case of frame loss. Valid range: 100..1461. notApplicable=0.
I32 prtExPVc4MultiplexInterval1.3.6.1.4.1.164.3.2.3.2.9.1.1.41Integer32read-writeDefines the maximum amout of time (msec.) between multiplexed frames that are sent. For Vmux-400/420 devices: It defines the Payload Packetizing Interval. Valid values: 10-90 msec. notApplicable=0.
INT prtExPVc4TransportProtocol1.3.6.1.4.1.164.3.2.3.2.9.1.1.42INTEGERread-writeTransport Protocol. ptp = point to point. aal2oMpls = AAL2 over MPLS.
INT prtExPVc4MultiFreqRelay1.3.6.1.4.1.164.3.2.3.2.9.1.1.43INTEGERread-writeThis object enables/disables Multi Frequency Signaling Detection.
I32 prtExPVc4MinPulseWidth1.3.6.1.4.1.164.3.2.3.2.9.1.1.44Integer32read-writeDefines the minimum Pulse Width in msec. Valid values: 45-100 msec. notApplicable=0.
I32 prtExPVc4MinPowerLevel1.3.6.1.4.1.164.3.2.3.2.9.1.1.45Integer32read-writeDefines the minimum Power Level in dBm. Valid values: -1..-35 dBm.
INT prtExPVc4SuperTandem1.3.6.1.4.1.164.3.2.3.2.9.1.1.46INTEGERread-writeThe Super Tandem feature provides end to end compression over multiple hops, solving the double compression problem detected in Voice compressing systems. The Super Tandem, when enabled, allows transmission of compressed voice between a few devices and eliminates the need to decompress an recompress it over each voice card and PBX, thus improving voice quality and reducing delay.
IP prtExPVc4DestIp1.3.6.1.4.1.164.3.2.3.2.9.1.1.47IpAddressread-writeThis object defines the destination IP Address.
I32 prtExPVc4DestBundle1.3.6.1.4.1.164.3.2.3.2.9.1.1.48Integer32read-writeThis object defines the destination Bundle at the far-end device.
IP prtExPVc4SrcIpAddress1.3.6.1.4.1.164.3.2.3.2.9.1.1.49IpAddressread-writeThis object defines the Source IP Address.
IP prtExPVc4SrcIpMask1.3.6.1.4.1.164.3.2.3.2.9.1.1.50IpAddressread-writeThis object defines the Source IP Mask.
IP prtExPVc4DefaultGateway1.3.6.1.4.1.164.3.2.3.2.9.1.1.51IpAddressread-writeThis object defines the Default Gateway for this interface.
U32 prtExPVc4SigPacketInterval1.3.6.1.4.1.164.3.2.3.2.9.1.1.52Unsigned32read-writeDefines the Signaling Packetizing Interval, which is the maximum time interval, measured in msec (milliseconds), between multiplexed signaling frames.
prtExPVc4DlciTable1.3.6.1.4.1.164.3.2.3.2.9.2not-accessibleThe write operation into the Table Objects is valid only at the TmpCnfg entry.
prtExPVc4DlciEntry1.3.6.1.4.1.164.3.2.3.2.9.2.1not-accessibleAn entry in table.
I32 prtExPVc4DlciCnfgIdx1.3.6.1.4.1.164.3.2.3.2.9.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtExPVc4DlciSltIdx1.3.6.1.4.1.164.3.2.3.2.9.2.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
INT prtExPVc4DlciPrtIdx1.3.6.1.4.1.164.3.2.3.2.9.2.1.3INTEGERread-onlyThis attribute indicates a unique internal port number. VC4 cards have four external ports.
INT prtExPVc4DlciValid1.3.6.1.4.1.164.3.2.3.2.9.2.1.4INTEGERread-writeThis attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object
INT prtExPVc4DlciIConSlt1.3.6.1.4.1.164.3.2.3.2.9.2.1.5INTEGERread-writeThis attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. In the ?004 Unit the entries io6(10)..io16) are not valid
INT prtExPVc4DlciIConPrt1.3.6.1.4.1.164.3.2.3.2.9.2.1.6INTEGERread-writeThis attribute indicates a unique port id which the dlci is routed to.
I32 prtExPVc4DlciIConDlci1.3.6.1.4.1.164.3.2.3.2.9.2.1.7Integer32read-writeThis attribute indicates a unique internal connection dlci number, the dlci is routed to.
INT prtExPVc4DlciTxBc1.3.6.1.4.1.164.3.2.3.2.9.2.1.8INTEGERread-writeThis attribute indicates a unique Tx committed bandwidth on the user transmit line (or at the port receive line).
INT prtExPVc4DlciTxBe1.3.6.1.4.1.164.3.2.3.2.9.2.1.9INTEGERread-writeThis attribute indicates a unique Tx excess bandwidth on the user transmit line (or at the port receive line).
INT prtExPVc4DlciRxBc1.3.6.1.4.1.164.3.2.3.2.9.2.1.10INTEGERread-writeThis attribute indicates a unique Rx committed bandwidth on the user receive line (or at the port transmit line).
INT prtExPVc4DlciRxBe1.3.6.1.4.1.164.3.2.3.2.9.2.1.11INTEGERread-writeThis attribute indicates a unique Rx excess bandwidth on the user receive line (or at the port transmit line).
I32 prtExPVc4DlciPriority1.3.6.1.4.1.164.3.2.3.2.9.2.1.12Integer32read-writeThis attribute indicates a unique priority of the pvc. 6 is the lowest priority and 8 is the highest priority.
INT prtExPVc4DlciStatus1.3.6.1.4.1.164.3.2.3.2.9.2.1.13INTEGERread-onlyThis attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
prtHsrCnfg1.3.6.1.4.1.164.3.2.3.2.10
prtExHsrCnfgTable1.3.6.1.4.1.164.3.2.3.2.10.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExHsrCnfgEntry1.3.6.1.4.1.164.3.2.3.2.10.1.1not-accessibleAn entry in table.
I32 prtExHsrCnfgIdx1.3.6.1.4.1.164.3.2.3.2.10.1.1.1Integer32read-onlyThis object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtExHsrSltIdx1.3.6.1.4.1.164.3.2.3.2.10.1.1.2INTEGERread-onlyThis object indicates a unique slot position where the card is inserted.
I32 prtExHsrPrtIdx1.3.6.1.4.1.164.3.2.3.2.10.1.1.3Integer32read-onlyA unique prt identifier within the card. Valid values: For MP: - For HS-R cards: exPrt1 (1) .. exPrt4 (4) - For HS-U/1 cards: inPrt1 (101) .. inPrt4 (104) - For HS-S12, HS-S6, HS-U12, HS-U6 cards: exPrt1 (1) .. exPrt12 (12). This MIB table is used only for LT-1 interface. For DXC: - For HS-U8, HS-U16 cards: 111 .. 2531 (See DXC R6 spec for port index convention). This MIB table is used only for LT-1 interface.
INT prtExHsrConnect1.3.6.1.4.1.164.3.2.3.2.10.1.1.4INTEGERread-writeThis object indicates whether the port should be considered in any of the mux algorithms.
INT prtExHsrProtocol1.3.6.1.4.1.164.3.2.3.2.10.1.1.5INTEGERread-writeThis object indicates the protocol.
INT prtExHsrRate1.3.6.1.4.1.164.3.2.3.2.10.1.1.6INTEGERread-writeThis object indicates the port speed. The 16,32,48,56,64 and 128 kbps rates are applicable only for Sync protocol. The 57.6 and 115.2 kbps rates are applicable only for Async protocol. notConnected= 0 rate.
INT prtExHsrDataBits1.3.6.1.4.1.164.3.2.3.2.10.1.1.7INTEGERread-writeData Bits. This object is applicable for Async protocol only.
INT prtExHsrParity1.3.6.1.4.1.164.3.2.3.2.10.1.1.8INTEGERread-write- For HS-R card, this object indicates if the parity bit is needed or not. Therefore, the 'no' and 'yes; values are applicable. - For HS-S12, HS-U12, the parity type is selected: no, odd, even. This object is applicable for Async protocol only.
INT prtExHsrStopBits1.3.6.1.4.1.164.3.2.3.2.10.1.1.9INTEGERread-writeThis object indicates the minimum number of stop bits in the tx async frame. This object is applicable for Async protocol only.
INT prtExHsrCts1.3.6.1.4.1.164.3.2.3.2.10.1.1.10INTEGERread-writeCTS. This object is applicable for Async protocol only.
INT prtExHsrClkMode1.3.6.1.4.1.164.3.2.3.2.10.1.1.11INTEGERread-writeClock mode. This object is applicable for Sync protocol only.
INT prtExHsrLinkTo1.3.6.1.4.1.164.3.2.3.2.10.1.1.12INTEGERread-writeIt indicates the slot of the main link card to which the HS-R card is mapped. notApplicable - for HS-U/1 internal ports. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
INT prtExHsrDcdDsr1.3.6.1.4.1.164.3.2.3.2.10.1.1.13INTEGERread-writeDCD & DSR.
INT prtExHsrOperMode1.3.6.1.4.1.164.3.2.3.2.10.1.1.14INTEGERread-writeThis object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request.
INT prtExHsrRtsDtr1.3.6.1.4.1.164.3.2.3.2.10.1.1.15INTEGERread-writeRTS & DTR.
INT prtExHsrLlbEnable1.3.6.1.4.1.164.3.2.3.2.10.1.1.16INTEGERread-writeEnable/Disable LLB.
INT prtExHsrRlbEnable1.3.6.1.4.1.164.3.2.3.2.10.1.1.17INTEGERread-writeEnable/Disable RLB.
INT prtExHsrRateAdapt1.3.6.1.4.1.164.3.2.3.2.10.1.1.18INTEGERread-writeRate Adaptation - takes a low rate and adapts it to 64Kbps. This object specifies the means this adaptation is done by.
INT prtExHsrRemoteModem1.3.6.1.4.1.164.3.2.3.2.10.1.1.19INTEGERread-writeRemote modem. asmi31s2 = ASMi-31/2
INT prtExHsrEncapsMode1.3.6.1.4.1.164.3.2.3.2.10.1.1.20INTEGERread-writeLow Speed encapsulation method over PCM. When Encapsulation mode is Latency optimized, only rates up to 19.2 are supported. In this case a double number of bits occupy the Time Slot. For up to 9.6 Kbps - 4 bits are occupied. For 14.4 & 19.2 Kbps - 8 bits are occupied. When Encapsulation Mode is Bandwidth Optimized: For up to 9.6 Kbps - 2 bits are occupied. For 14.4 & 19.2 Kbps - 4 bits are occupied. For higher rates - 8 bits are occupied.
prtMbeCnfg1.3.6.1.4.1.164.3.2.3.2.11
prtExMbeCnfgTable1.3.6.1.4.1.164.3.2.3.2.11.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExMbeCnfgEntry1.3.6.1.4.1.164.3.2.3.2.11.1.1not-accessibleAn entry in table.
I32 prtExMbeCnfgIdx1.3.6.1.4.1.164.3.2.3.2.11.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtExMbeSltIdx1.3.6.1.4.1.164.3.2.3.2.11.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
INT prtExMbePrtIdx1.3.6.1.4.1.164.3.2.3.2.11.1.1.3INTEGERread-onlyA unique port identifier within the card.
INT prtExMbeLan1.3.6.1.4.1.164.3.2.3.2.11.1.1.4INTEGERread-writeThis attribute indicates whether the MBE port is operated as main or remote bridge.
prtInMbeCnfgTable1.3.6.1.4.1.164.3.2.3.2.11.2not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtInMbeCnfgEntry1.3.6.1.4.1.164.3.2.3.2.11.2.1not-accessibleAn entry in table.
I32 prtInMbeCnfgIdx1.3.6.1.4.1.164.3.2.3.2.11.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtInMbeSltIdx1.3.6.1.4.1.164.3.2.3.2.11.2.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
INT prtInMbePrtIdx1.3.6.1.4.1.164.3.2.3.2.11.2.1.3INTEGERread-onlyA unique port identifier within the card.
INT prtInMbeConnect1.3.6.1.4.1.164.3.2.3.2.11.2.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtInMbeRate1.3.6.1.4.1.164.3.2.3.2.11.2.1.5INTEGERread-writeThis attribute indicates the port speed.
INT prtInMbeLinkTo1.3.6.1.4.1.164.3.2.3.2.11.2.1.6INTEGERread-writeIt indicates the slot of the main link card to which the MBE card is mapped. In the ?004 Unit the entries io6(10)..io16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
prtTreCnfg1.3.6.1.4.1.164.3.2.3.2.12
prtExTreCnfgTable1.3.6.1.4.1.164.3.2.3.2.12.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExTreCnfgEntry1.3.6.1.4.1.164.3.2.3.2.12.1.1not-accessibleAn entry in table.
I32 prtExTreCnfgIdx1.3.6.1.4.1.164.3.2.3.2.12.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtExTreSltIdx1.3.6.1.4.1.164.3.2.3.2.12.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
INT prtExTrePrtIdx1.3.6.1.4.1.164.3.2.3.2.12.1.1.3INTEGERread-onlyA unique port identifier within the card.
INT prtExTreLan1.3.6.1.4.1.164.3.2.3.2.12.1.1.4INTEGERread-writeThis attribute indicates whether the TRE port is operated as main or remote bridge. Default=remote.
INT prtExTreLanRate1.3.6.1.4.1.164.3.2.3.2.12.1.1.5INTEGERread-writeThis attribute indicates the Rate of the TRE port in Mbit/sec. Default-r4M.
prtInTreCnfgTable1.3.6.1.4.1.164.3.2.3.2.12.2not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtInTreCnfgEntry1.3.6.1.4.1.164.3.2.3.2.12.2.1not-accessibleAn entry in table.
I32 prtInTreCnfgIdx1.3.6.1.4.1.164.3.2.3.2.12.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtInTreSltIdx1.3.6.1.4.1.164.3.2.3.2.12.2.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
INT prtInTrePrtIdx1.3.6.1.4.1.164.3.2.3.2.12.2.1.3INTEGERread-onlyA unique port identifier within the card.
INT prtInTreConnect1.3.6.1.4.1.164.3.2.3.2.12.2.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtInTreRate1.3.6.1.4.1.164.3.2.3.2.12.2.1.5INTEGERread-writeThis attribute indicates the port speed.
INT prtInTreLinkTo1.3.6.1.4.1.164.3.2.3.2.12.2.1.6INTEGERread-writeIt indicates the slot of the main link card to which the MBE card is mapped. In the ?004 Unit the entries io6(10)..io16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
prtLs6Cnfg1.3.6.1.4.1.164.3.2.3.2.13
prtExLs6CnfgTable1.3.6.1.4.1.164.3.2.3.2.13.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExLs6CnfgEntry1.3.6.1.4.1.164.3.2.3.2.13.1.1not-accessibleAn entry in table.
I32 prtExLs6CnfgIdx1.3.6.1.4.1.164.3.2.3.2.13.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtExLs6SltIdx1.3.6.1.4.1.164.3.2.3.2.13.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
INT prtExLs6PrtIdx1.3.6.1.4.1.164.3.2.3.2.13.1.1.3INTEGERread-onlyThis attribute indicates a unique port index.
INT prtExLs6Connect1.3.6.1.4.1.164.3.2.3.2.13.1.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtExLs6Protocol1.3.6.1.4.1.164.3.2.3.2.13.1.1.5INTEGERread-writeThis attribute indicates the protocol. async - can be selected only for ports 1-2.
INT prtExLs6Rate1.3.6.1.4.1.164.3.2.3.2.13.1.1.6INTEGERread-writePort rates in bps. g1 - contains the values : (2)-(6),(9),(12),(16) g2 - contains the values : (7),(10),(14),(19) g3 - contains the values : (8),(11),(13),(15),(17),(18),(20); it is not applicable when using Async protocol. Rates of pair ports (1-2, 3-4, 5-6) must be from the same group.
INT prtExLs6ClkMode1.3.6.1.4.1.164.3.2.3.2.13.1.1.7INTEGERread-writeThis attribute indicates a unique port operation clock mode. It is applicable for Sync protocol only .
INT prtExLs6CtrlSignal1.3.6.1.4.1.164.3.2.3.2.13.1.1.8INTEGERread-writeControl Signal.
INT prtExLs6DataBits1.3.6.1.4.1.164.3.2.3.2.13.1.1.9INTEGERread-writeData Bits. This object is applicable for Async protocol only.
INT prtExLs6Cts1.3.6.1.4.1.164.3.2.3.2.13.1.1.10INTEGERread-writeThis object indicates the CTS control line operation mode.
INT prtExLs6LinkToInternal1.3.6.1.4.1.164.3.2.3.2.13.1.1.11INTEGERread-writeThis object indicates which internal port of the card, the external port is linked to.
prtExLs6VCnfgTable1.3.6.1.4.1.164.3.2.3.2.13.2not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExLs6VCnfgEntry1.3.6.1.4.1.164.3.2.3.2.13.2.1not-accessibleAn entry in table.
I32 prtExLs6VCnfgIdx1.3.6.1.4.1.164.3.2.3.2.13.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtExLs6VSltIdx1.3.6.1.4.1.164.3.2.3.2.13.2.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
INT prtExLs6VPrtIdx1.3.6.1.4.1.164.3.2.3.2.13.2.1.3INTEGERread-onlyA unique identifier of the port, within the card.
INT prtExLs6VConnect1.3.6.1.4.1.164.3.2.3.2.13.2.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtExLs6VRate1.3.6.1.4.1.164.3.2.3.2.13.2.1.5INTEGERread-writeRate (bps) used for FAX transmission and Voice coding.
INT prtExLs6VEchoCanceler1.3.6.1.4.1.164.3.2.3.2.13.2.1.6INTEGERread-writeEcho canceler activation.
INT prtExLs6VIfType1.3.6.1.4.1.164.3.2.3.2.13.2.1.7INTEGERread-writeThis attribute indicates the interface type of the port. w4wire - is applicable only for E&M port type.
I32 prtExLs6VTxGain1.3.6.1.4.1.164.3.2.3.2.13.2.1.8Integer32read-writeTransmit gain in dBm. E&M - values range: -17 .. 8 FXO - values range: -16 .. 4 FXS - values range: -13 .. 8
I32 prtExLs6VRxGain1.3.6.1.4.1.164.3.2.3.2.13.2.1.9Integer32read-writeReceive gain in dBm. E&M - values range: -17 .. 2 FXO - values range: -17 .. -1 FXS - values range: -17 .. 2
INT prtExLs6VOos1.3.6.1.4.1.164.3.2.3.2.13.2.1.10INTEGERread-writeOut of Service signaling mode.
prtInLs6CnfgTable1.3.6.1.4.1.164.3.2.3.2.13.3not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtInLs6CnfgEntry1.3.6.1.4.1.164.3.2.3.2.13.3.1not-accessibleAn entry in table.
I32 prtInLs6CnfgIdx1.3.6.1.4.1.164.3.2.3.2.13.3.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtInLs6SltIdx1.3.6.1.4.1.164.3.2.3.2.13.3.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
INT prtInLs6PrtIdx1.3.6.1.4.1.164.3.2.3.2.13.3.1.3INTEGERread-onlyThis attribute indicates a unique internal port index.
INT prtInLs6Connect1.3.6.1.4.1.164.3.2.3.2.13.3.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the module considerations because the module has only one Internal interface which is the composite channel.
INT prtInLs6TandemMode1.3.6.1.4.1.164.3.2.3.2.13.3.1.5INTEGERread-writeThis object indicates the Tandem Mode. tandemSlave - is valid only for an LS-6 card having on the (current slot-1) an LS-6 card with 'tandemMaster' mode.
INT prtInLs6Rate1.3.6.1.4.1.164.3.2.3.2.13.3.1.6INTEGERread-writeMain Rate in Kbps.
INT prtInLs6RemoteType1.3.6.1.4.1.164.3.2.3.2.13.3.1.7INTEGERread-writeRemote Type. notApplicable - when prtInLs6TandemMode=tandemSlave
INT prtInLs6LinkTo1.3.6.1.4.1.164.3.2.3.2.13.3.1.8INTEGERread-writeIt indicates the slot of the main link card to which the Ls6 card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - when prtInLs6TandemMode=tandemSlave. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
prtVc3Cnfg1.3.6.1.4.1.164.3.2.3.2.14
prtExVc3CnfgTable1.3.6.1.4.1.164.3.2.3.2.14.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExVc3CnfgEntry1.3.6.1.4.1.164.3.2.3.2.14.1.1not-accessibleAn entry in table.
I32 prtExVc3CnfgIdx1.3.6.1.4.1.164.3.2.3.2.14.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtExVc3SltIdx1.3.6.1.4.1.164.3.2.3.2.14.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
INT prtExVc3PrtIdx1.3.6.1.4.1.164.3.2.3.2.14.1.1.3INTEGERread-onlyA unique identifier of the port, within the card.
INT prtExVc3Connect1.3.6.1.4.1.164.3.2.3.2.14.1.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
I32 prtExVc3TransGain1.3.6.1.4.1.164.3.2.3.2.14.1.1.5Integer32read-writeTransmit gain in dBm.
I32 prtExVc3ReceiveGain1.3.6.1.4.1.164.3.2.3.2.14.1.1.6Integer32read-writeReceive gain in dBm.
INT prtExVc3Wire1.3.6.1.4.1.164.3.2.3.2.14.1.1.7INTEGERread-writeThis object is equal for all the ports in the specific card because of HW limitations
INT prtExVc3Rate1.3.6.1.4.1.164.3.2.3.2.14.1.1.8INTEGERread-writeRate in bps.
INT prtExVc3EchoCanceler1.3.6.1.4.1.164.3.2.3.2.14.1.1.9INTEGERread-writeEcho canceler activation. The value will be the same for all the card's external ports.
prtInVc3CnfgTable1.3.6.1.4.1.164.3.2.3.2.14.2not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtInVc3CnfgEntry1.3.6.1.4.1.164.3.2.3.2.14.2.1not-accessibleAn entry in table.
I32 prtInVc3CnfgIdx1.3.6.1.4.1.164.3.2.3.2.14.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtInVc3SltIdx1.3.6.1.4.1.164.3.2.3.2.14.2.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
INT prtInVc3PrtIdx1.3.6.1.4.1.164.3.2.3.2.14.2.1.3INTEGERread-onlyA unique identifier of the port, within the card.
INT prtInVc3Connect1.3.6.1.4.1.164.3.2.3.2.14.2.1.4INTEGERread-writeThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtInVc3Rate1.3.6.1.4.1.164.3.2.3.2.14.2.1.5INTEGERread-writeRate in bps.
INT prtInVc3Oos1.3.6.1.4.1.164.3.2.3.2.14.2.1.6INTEGERread-writeThis object is equal for all the ports in the specific card because of HW limitations
INT prtInVc3LinkTo1.3.6.1.4.1.164.3.2.3.2.14.2.1.7INTEGERread-writeThis attribute indicates the slot of the ML card to which the VC card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
prtVcPbxCnfg1.3.6.1.4.1.164.3.2.3.2.15
prtExVcPbxCnfgTable1.3.6.1.4.1.164.3.2.3.2.15.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtExVcPbxCnfgEntry1.3.6.1.4.1.164.3.2.3.2.15.1.1not-accessibleAn entry in table.
I32 prtExVcPbxCnfgIdx1.3.6.1.4.1.164.3.2.3.2.15.1.1.1Integer32read-onlyThis object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtExVcPbxSltIdx1.3.6.1.4.1.164.3.2.3.2.15.1.1.2INTEGERread-onlyThis object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
INT prtExVcPbxPrtIdx1.3.6.1.4.1.164.3.2.3.2.15.1.1.3INTEGERread-onlyA unique identifier of the port, within the card.
INT prtExVcPbxConnect1.3.6.1.4.1.164.3.2.3.2.15.1.1.4INTEGERread-writeThis object indicates whether the port should be considered in any of the mux algorithms.
INT prtExVcPbxGroup1.3.6.1.4.1.164.3.2.3.2.15.1.1.5INTEGERread-onlyThe group object links together several VC-PBX cards, concerning compression of the same input T1/E1 link time-slots. When ports of different slots have the same group, they are linked. When ports have a different group, they are not linked. For VC-PBX/T1 and E1 cards, this object is - their own IO Slot. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
INT prtExVcPbxTransparent1.3.6.1.4.1.164.3.2.3.2.15.1.1.6INTEGERread-writeThis object indicates whether the Transparent transfer of Time-Slots is required or not. Time-Slots transferred by Transparent, will not be compressed. no - applicable only for VC-PBX/T1 and VC-PBX/E1 cards yes - applicable only for VC-PBX/T1 and VC-PBX/E1 cards notApplicable - only for VC-PBX cards.
I32 prtExVcPbxTransSignalTs1.3.6.1.4.1.164.3.2.3.2.15.1.1.7Integer32read-writeThis object specifies the ML Time-Slot dedicated to the signaling of the PABX Transparent TSs. None = 255. When prtExVcPbxTransparent=no this object's value=None (255) When prtExVcPbxTransparent=notApplicable, this object's value=None (255). When prtExVcPbxTransparent=yes: - for VC-PBX/T1 ports, this object's valid values are 1..16 or None (255). - for VC-PBX/E1 ports, this object's value will be 16 or None (255).
INT prtExVcPbxFrame1.3.6.1.4.1.164.3.2.3.2.15.1.1.8INTEGERread-writeThis object is the frame parameter for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 values for the VC-PBX/T1 card. E1 values for the VC-PBX/E1 card. notApplicable - for the VC-PBX card. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) esfT1 dsx1ESF (2) sfT1 dsx1D4 (3) g732nE1 dsx1E1 (4) g732nE1CRC dsx1E1-CRC (5) g732sE1 dsx1E1-MF (6) g732sE1CRC dsx1E1-MF-CRC (7)
INT prtExVcPbxRestoreTime1.3.6.1.4.1.164.3.2.3.2.15.1.1.9INTEGERread-writeThe time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface. ccittE1 - is applicable only for VC-PBX/E1 card notApplicable - is applicable for VC-PBX card
INT prtExVcPbxLineCode1.3.6.1.4.1.164.3.2.3.2.15.1.1.10INTEGERread-writeThis object is the line code parameter used for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for VC-PBX/T1 E1 line code parameters for VC-PBX/E1 notApplicable - for VC-PBX This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)
INT prtExVcPbxLineLength1.3.6.1.4.1.164.3.2.3.2.15.1.1.11INTEGERread-writeThis object is the line length parameter. It is applicable only for the VC-PBX/T1 card. notApplicable - for the VC-PBX and VC-PBX/E1 card. lenXXXpXXXft = len-XXX-XXXft.
INT prtExVcPbxLinkTo1.3.6.1.4.1.164.3.2.3.2.15.1.1.12INTEGERread-writeThis object indicates the slot of the ML card to which the VC-PBX/T1, VC-PBX/E1 card Transparent TSs are mapped. notApplicable - for VC-PBX card AND for VC-PBX/T1, VC-PBX/E1 cards, when prtExVcPbxTransparent=no . In the ?004 Unit the entries io6(10)..io12(16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
INT prtExVcPbxSignalOper1.3.6.1.4.1.164.3.2.3.2.15.1.1.13INTEGERread-writeThis object indicates the Signaling Operation of the VC-PBX/T1, VC-PBX/E1 external port. notApplicable - for VC-PBX card normal - all 4 signaling bits are transferred. bEqA - copy the A bit into the B bit. Applicable only for VC-PBX/T1.
INT prtExVcPbxIdleCode1.3.6.1.4.1.164.3.2.3.2.15.1.1.14INTEGERread-writeDetermines the code for transmission in empty time slots. notApplicable - for VC-PBX card .
prtIn1p6VcPbxCnfgTable1.3.6.1.4.1.164.3.2.3.2.15.2not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtIn1p6VcPbxCnfgEntry1.3.6.1.4.1.164.3.2.3.2.15.2.1not-accessibleAn entry in table.
I32 prtIn1p6VcPbxCnfgIdx1.3.6.1.4.1.164.3.2.3.2.15.2.1.1Integer32read-onlyThis object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtIn1p6VcPbxSltIdx1.3.6.1.4.1.164.3.2.3.2.15.2.1.2INTEGERread-onlyThis object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
INT prtIn1p6VcPbxPrtIdx1.3.6.1.4.1.164.3.2.3.2.15.2.1.3INTEGERread-onlyA unique identifier of the port, within the card.
INT prtIn1p6VcPbxConnect1.3.6.1.4.1.164.3.2.3.2.15.2.1.4INTEGERread-writeThis object indicates whether the port should be considered in any of the mux algorithms.
INT prtIn1p6VcPbxRate1.3.6.1.4.1.164.3.2.3.2.15.2.1.5INTEGERread-writeThis object indicates the port Rate. For Normal mode (prtIn7p8VcPbxMode=normal), only part of the values are valid (constant rate). For Server mode (prtIn7p8VcPbxMode=server), all values are applicable (user can select the desired compression rate).
INT prtIn1p6VcPbxEchoCanceler1.3.6.1.4.1.164.3.2.3.2.15.2.1.6INTEGERread-writeEcho canceler activation.
I32 prtIn1p6VcPbxPabxTs1.3.6.1.4.1.164.3.2.3.2.15.2.1.7Integer32read-onlyThis object defines the PABX Time-Slot assigned to this internal port. For a T1 link, the valid values are: 1 .. 24. For an E1 link, the valid values are: 1 .. 31. This object is NOT applicable when prtIn1p6VcPbxConnect=no. This object is applicable for all cards of VC-PBX family. Default=the internal port index (1..6).
prtIn7p8VcPbxCnfgTable1.3.6.1.4.1.164.3.2.3.2.15.3not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtIn7p8VcPbxCnfgEntry1.3.6.1.4.1.164.3.2.3.2.15.3.1not-accessibleAn entry in table.
I32 prtIn7p8VcPbxCnfgIdx1.3.6.1.4.1.164.3.2.3.2.15.3.1.1Integer32read-onlyThis object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
INT prtIn7p8VcPbxSltIdx1.3.6.1.4.1.164.3.2.3.2.15.3.1.2INTEGERread-onlyThis object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
INT prtIn7p8VcPbxPrtIdx1.3.6.1.4.1.164.3.2.3.2.15.3.1.3INTEGERread-onlyA unique identifier of the port, within the card.
INT prtIn7p8VcPbxConnect1.3.6.1.4.1.164.3.2.3.2.15.3.1.4INTEGERread-writeThis object indicates whether the port should be considered in any of the mux algorithms.
INT prtIn7p8VcPbxMode1.3.6.1.4.1.164.3.2.3.2.15.3.1.5INTEGERread-writeThis object indicates the working mode of the port: - normal - the compressed voice will be sent to an MTML card inside the Mux. - server - the compressed voice will be sent to the Digital Voice connector, as a service to an outside user.
INT prtIn7p8VcPbxRate1.3.6.1.4.1.164.3.2.3.2.15.3.1.6INTEGERread-writeThis object indicates the port Main Rate. For Server mode (prtIn7p8VcPbxMode=server), the value will be notApplicable.
INT prtIn7p8VcPbxSignalMode1.3.6.1.4.1.164.3.2.3.2.15.3.1.7INTEGERread-writeThis object indicates the Signal Mode. For Server mode (prtIn7p8VcPbxMode=server), the only valid values are: - none - aBit
INT prtIn7p8VcPbxOos1.3.6.1.4.1.164.3.2.3.2.15.3.1.8INTEGERread-writeOut of service Signaling mode.
INT prtIn7p8VcPbxLinkTo1.3.6.1.4.1.164.3.2.3.2.15.3.1.9INTEGERread-writeThis object indicates the slot of the ML card to which the VC card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For Server mode (prtIn7p8VcPbxMode=server), this object is not applicable. Both ports, 7 and 8 should be linked to the same Slot. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
prtExVcPbxTsTable1.3.6.1.4.1.164.3.2.3.2.15.4not-accessibleThe write operation into the table objects is valid only to the TmpCnfg entry.
prtExVcPbxTsEntry1.3.6.1.4.1.164.3.2.3.2.15.4.1not-accessibleAn entry in table.
I32 prtExVcPbxTsCnfgIdx1.3.6.1.4.1.164.3.2.3.2.15.4.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtExVcPbxTsSltIdx1.3.6.1.4.1.164.3.2.3.2.15.4.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid
INT prtExVcPbxTsPrtIdx1.3.6.1.4.1.164.3.2.3.2.15.4.1.3INTEGERread-onlyThis attribute indicates a unique port number. VCPBX/E1, VCPBX/T1, VFPBX/E1, VFPBX/T1, VF-24/T1 and VF-30 cards have only one external interface. VF-48/T1 and VF-60/E1 cards have two external interfaces. VFS cards have also internal ports.
I32 prtExVcPbxTsIdx1.3.6.1.4.1.164.3.2.3.2.15.4.1.4Integer32read-onlyThis attribute indicates a unique PABX time slot position. The valid time slots are 1..24 for T1 cards and 1..31 for E1 cards.
INT prtExVcPbxTsMode1.3.6.1.4.1.164.3.2.3.2.15.4.1.5INTEGERread-writeThis attribute indicates the usage, process and way of the specific PABX TS towards its destination: unused - the TS is not used (no processing, no destination). compressed - the TS is used, sent for compression to an internal port (for VF-PBX cards: 1..6 for of either the same card or a VF-PBX card of the same group). For VF-24/30/48/60 - 'compressed' represents 'compressed Voice' (to differentiate it from 'compressedCcs'). In this case, the TS is compressed by an internal port (1..8). transparent - the TS is used; no processing. It is sent directly for Bypass to a ML card the VF port/TS is linked to. compressedCcs - supported only by VF-24/30/48/60 cards. The TS is used; sent for compression to the CPU. mng - the TS is used for Management (this option is used when the external port is connected to another product that has to be managed via this dedicated TS. ccs1..ccs8 - supported only by VF-24/30/48/60 cards. Compressed TS that comes from a bundle of V5.1 or V5.2 PBX. ss7n1..ss7n8 - supported only by VF-24/30/48/60 cards. Compressed TS that comes from a bundle of V5.1 or V5.2 PBX. ss7n1 can work versus Vmux having prtExPh1MlTsType=ss7(6).
INT prtExVcPbxTsIConSlot1.3.6.1.4.1.164.3.2.3.2.15.4.1.6INTEGERread-writeFor VF-PBX cards, the io1..io12 values are applicable only when prtExVcPbxTsMode=compressed. Otherwise, its value should be noConnect. For VF-24/30/48/60 cards: - when prtExVcPbxTsMode=transparent or voiceTransparent, the io1..io12 values are applicable, indicating the ML Slot this TS is connected to. - when prtExVcPbxTsMode=compressed or compressedCcs, the value will be the same as prtExVcPbxTsSltIdx, since the compression is done within the same card. - for rest of the prtExVcPbxTsMode values, the value will be: noConnect. This object indicates whether the specified compressed/transparent time slot is connected/routed internally in the Agent and to which card it is connected. For VF-PBX card, the valid selectable slots are either the current one, (prtExVcPbxTsSltIdx), or a slot containing a VF-PBX card. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
INT prtExVcPbxTsIConPrt1.3.6.1.4.1.164.3.2.3.2.15.4.1.7INTEGERread-writeThis attribute indicates the port to which this TS is connected. For VF-PBX cards, only inPrt1..inPrt6 ports are valid. For VF-24/30/48/60 cards: - for prtExVcPbxTsMode=transparent or voiceTransparent, the valid ports are ML ports (exPrt1.. exPrt8, inPrt1.. inPrt8) - for prtExVcPbxTsMode=compressed or compressedCcs, the valid ports are internal ports of the same card (inPrt1..inPrt8) noConnect - when prtExVcPbxTsIConSlot=noConnect.
I32 prtExVcPbxTsIConTs1.3.6.1.4.1.164.3.2.3.2.15.4.1.8Integer32read-writeThis attribute indicates the ML TS to which this TS is connected. This object is not applicable for VF-PBX cards. For VF-24/30/48/60 cards it is applicable only when prtExVcPbxTsMode=transparent or voiceTransparent. The valid time slots are 1..24 for ML T1 cards and 1..31 for ML E1 cards. notApplicable - 255.
INT prtExVcPbxTsRemPrt1.3.6.1.4.1.164.3.2.3.2.15.4.1.9INTEGERread-writeThis attribute indicates the end-point port on the Remote unit. VF-24/T1 and VF-30/E1 cards have one external interface. VF-48/T1 and VF-60/E1 cards have two external interfaces. noConnect - when prtExVcPbxTsMode=unused, transparent, voiceTransparent or mng.
I32 prtExVcPbxTsRemTs1.3.6.1.4.1.164.3.2.3.2.15.4.1.10Integer32read-writeThis attribute indicates the end-point TS on the Remote unit. The valid time slots are 1..24 for T1 ports and 1..31 for E1 ports. notApplicable - 255.
U32 prtExVcPbxTsRemConnID1.3.6.1.4.1.164.3.2.3.2.15.4.1.11Unsigned32read-writeThis attribute indicates the Connection ID with the Remote unit. notApplicable = 0.
INT prtExVcPbxTsSourceSlot1.3.6.1.4.1.164.3.2.3.2.15.4.1.12INTEGERread-writeFor VFS cards. These cards offer Compresed Voice Services for Analog Voice ports of the MP. This object indicates the Source Slot of the Analog Voice port we want to compress. io1..io12 values are applicable only when prtExVcPbxTsMode=compressed(voice). Otherwise, its value should be noConnect. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
U32 prtExVcPbxTsSourcePrt1.3.6.1.4.1.164.3.2.3.2.15.4.1.13Unsigned32read-writeFor VFS cards. These cards offer Compresed Voice Services for Analog Voice ports of the MP. This object indicates the Source Port within the Slot of the Analog Voice Card, we want to compress. exPrt1 - exPrt16 = 1 - 16 noConnect=100 - when prtExVcPbxTsCvServiceSlot=noConnect.
prtIsdnCnfg1.3.6.1.4.1.164.3.2.3.2.16
prtIsdnCnfgTable1.3.6.1.4.1.164.3.2.3.2.16.1not-accessibleThe write operation into the table objects is valid only to the TmpCnfg entry.
prtIsdnCnfgEntry1.3.6.1.4.1.164.3.2.3.2.16.1.1not-accessibleAn entry in table.
I32 prtIsdnCnfgIdx1.3.6.1.4.1.164.3.2.3.2.16.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtIsdnSltIdx1.3.6.1.4.1.164.3.2.3.2.16.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'
I32 prtIsdnPrtIdx1.3.6.1.4.1.164.3.2.3.2.16.1.1.3Integer32read-onlyThis attribute indicates a unique port number. For MAXcess the values will be: exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), For KM-2100 the port index is calculated as follows: 100*Slot+Ch
INT prtIsdnConnect1.3.6.1.4.1.164.3.2.3.2.16.1.1.4INTEGERread-writeThis attribute indicates if the port is connected.
INT prtIsdnSignalingProtocol1.3.6.1.4.1.164.3.2.3.2.16.1.1.5INTEGERread-writeThis attribute fixes which signaling protocol is used at this port (D-Channel). It is equivalent to isdnSignalingProtocol in the isdn MIB.
INT prtIsdnBasicRateLineTopology1.3.6.1.4.1.164.3.2.3.2.16.1.1.6INTEGERread-writeThis attribute is relevant for ISDN BRI only. It is equivalent to isdnBasicRateLineTopology in the isdn MIB.
INT prtIsdnMode1.3.6.1.4.1.164.3.2.3.2.16.1.1.7INTEGERread-writeThis attribute allows the user to configure the port as leased(2) in case of connection to a TDM network.
INT prtIsdnFilter1.3.6.1.4.1.164.3.2.3.2.16.1.1.8INTEGERread-writeThis attribute allows the user to configure the port: answerAll(2): accept all incoming calls, rejectAll(3): reject all incoming calls, selective(4): accept or reject according directory table. callBack (5): In this mode the ISDN Ch will reject incoming calls and will initiate call back to the rejected phone number.
INT prtIsdnSimultaneousCall1.3.6.1.4.1.164.3.2.3.2.16.1.1.9INTEGERread-writeIn case of simultaneous call (local,remote and remote,local): accept(2): accept the incoming call, reject(3): reject the incoming call.
I32 prtIsdnNumOfAbstractTerm1.3.6.1.4.1.164.3.2.3.2.16.1.1.10Integer32read-writeAn object for KM2100/4 agents. 255=Not Applicable When ISDN Standard = ETSI or NTT (European) the value should be 255 (NotApplicable) else If ML speed is 64Kbps value should be 1. If ML speed is 128Kbps value can be either 1 or 2 (user selection).
INT prtIsdnSwitchMode1.3.6.1.4.1.164.3.2.3.2.16.1.1.11INTEGERread-writeFor KM2100. auto - The call is initiated automatically by one of the IO cards connected to KML.10(ISDN card) having ISDN Switch Mode. manual - The call is initiated by the user manually, for KML.10 having ISDN Switch Mode (via mdlSCmd). connect- The call is initiated 'immediately', for KML.10 having ISDN Switch Mode. 'immediately'- means: immediately after power-up (when product performed Reset) OR, since this value appears in the active configuration. In this case, the call can be disconnected only by power-off of the product or by changing this object to another value (or actual Remove of the KML.10 relevant card). notApplicable - For other card types.
INT prtIsdnAbSide1.3.6.1.4.1.164.3.2.3.2.16.1.1.12INTEGERread-writeThis parameter indicates the QSIG side in layer 3. This definition is from the QSIG Standard.
INT prtIsdnQsigRole1.3.6.1.4.1.164.3.2.3.2.16.1.1.13INTEGERread-writeThis parameter indicates the QSIG side in layer 1 & 2.
INT prtIsdnInterface1.3.6.1.4.1.164.3.2.3.2.16.1.1.14INTEGERread-writeIt indicates the interface type: lt = line termination nt = network termination te = terminal equipment.
INT prtIsdnCallMode1.3.6.1.4.1.164.3.2.3.2.16.1.1.15INTEGERread-writeThis object indicates the acceptance of incoming calls. Initiate - Callout Listen - Callin.
I32 prtIsdnCallBackTimeout1.3.6.1.4.1.164.3.2.3.2.16.1.1.16Integer32read-writeThis object is applicable only if 'prtIsdnFilter' is 'CallBack' and determines how long to wait from receiving the incoming call until initiating the call back call. The vaules range should be '1..20 sec' and the default 10 sec.
prtIsdnEndpointTable1.3.6.1.4.1.164.3.2.3.2.16.2not-accessibleThe write operation into the table objects is valid only to the TmpCnfg entry.
prtIsdnEndpointEntry1.3.6.1.4.1.164.3.2.3.2.16.2.1not-accessibleAn entry in table.
I32 prtIsdnEndpointCnfgIdx1.3.6.1.4.1.164.3.2.3.2.16.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtIsdnEndpointSltIdx1.3.6.1.4.1.164.3.2.3.2.16.2.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. In ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'
I32 prtIsdnEndpointPrtIdx1.3.6.1.4.1.164.3.2.3.2.16.2.1.3Integer32read-onlyThis attribute indicates a unique port number. For MAXcess the values will be: exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), For KM-2100 the port index is calculated as follows: 100*Slot+Ch
INT prtIsdnEndpointIdx1.3.6.1.4.1.164.3.2.3.2.16.2.1.4INTEGERread-onlySince more than one endpoint may be defined per isdn entity, this field is a simple index. It corresponds to isdnEndpointIdx in the isdn MIB.
INT prtIsdnEndpointTeiType1.3.6.1.4.1.164.3.2.3.2.16.2.1.5INTEGERread-createThe type of TEI (Terminal Endpoint Identifier) used for this Terminal Endpoint. In case of dynamic(1), the TEI value is selected by the switch. In case of static(2), a valid TEI value has to be entered in the isdnEndpointTeiValue object. interface type as well as the Terminal Endpoint type. static(2). On Basic Rate interfaces the default value is dynamic(1) for isdn(63) Terminal Endpoints. It corresponds to isdnEndpointTeiType in the isdn MIB.
I32 prtIsdnEndpointTeiValue1.3.6.1.4.1.164.3.2.3.2.16.2.1.6Integer32read-createWhen the TEI Type is static, the value of the TEI should be between 0 and 63. Else, it is not selectable by user. 255 = notApplicable. It corresponds to isdnEndpointTeiValue in the isdn MIB
STR prtIsdnEndpointSpid1.3.6.1.4.1.164.3.2.3.2.16.2.1.7DisplayStringread-createThe Service profile IDentifier (SPID) information for this Terminal Endpoint. It is is composed of 9-20 numeric characters. It corresponds to isdnEndpointSpid in the isdn MIB.
INT prtIsdnEndpointBearerCh1.3.6.1.4.1.164.3.2.3.2.16.2.1.8INTEGERread-createThis is the selected dialing channel. anyChannel - the system selects the dialing channel.
ROW prtIsdnEndpointRowStatus1.3.6.1.4.1.164.3.2.3.2.16.2.1.9RowStatusread-createThis field indicates whether to consider this endpoint or not. The only possible supported RowStatus vaules are active (1) and destroy (6).
prtIsdnDirectoryTable1.3.6.1.4.1.164.3.2.3.2.16.3not-accessibleThe write operation into the table objects is valid only to the TmpCnfg entry.
prtIsdnDirectoryEntry1.3.6.1.4.1.164.3.2.3.2.16.3.1not-accessibleAn entry in table.
I32 prtIsdnDirectoryCnfgIdx1.3.6.1.4.1.164.3.2.3.2.16.3.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtIsdnDirectorySltIdx1.3.6.1.4.1.164.3.2.3.2.16.3.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the card is inserted. For MX300/30 ports: io1(5) = isdn1(5) and io2(6) = isdn2(6). In ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'
I32 prtIsdnDirectoryPrtIdx1.3.6.1.4.1.164.3.2.3.2.16.3.1.3Integer32read-onlyFor MAXcess this is the internal port number: 101, 102,.... For KM-2100 the port index is calculated as follows: 100*Slot+Ch
STR prtIsdnDirectoryLocalAddr1.3.6.1.4.1.164.3.2.3.2.16.3.1.4DisplayStringread-createThis is the local address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)
STR prtIsdnDirectoryLocalSubAddr1.3.6.1.4.1.164.3.2.3.2.16.3.1.5DisplayStringread-createThis is the local subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
STR prtIsdnDirectoryRemoteAddr1.3.6.1.4.1.164.3.2.3.2.16.3.1.6DisplayStringread-createThis is the remote address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)
STR prtIsdnDirectoryRemoteSubAddr1.3.6.1.4.1.164.3.2.3.2.16.3.1.7DisplayStringread-createThis is the remote subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
I32 prtIsdnDirectoryPrtNu1.3.6.1.4.1.164.3.2.3.2.16.3.1.8Integer32read-createThis is the external port number connected to this entry.
I32 prtIsdnDirectoryTeiId1.3.6.1.4.1.164.3.2.3.2.16.3.1.9Integer32read-createThis is the abstract terminal id if relevant, connected to this entry.
ROW prtIsdnDirectoryRowStatus1.3.6.1.4.1.164.3.2.3.2.16.3.1.10RowStatusread-createThis is the status for the row. It allows to know whether to consider this row or not. The only possible supported RowStatus vaules are active (1) and destroy (6).
STR prtIsdnDirectoryLocalAddr21.3.6.1.4.1.164.3.2.3.2.16.3.1.11DisplayStringread-createThis is the second local address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)
STR prtIsdnDirectoryLocalSubAddr21.3.6.1.4.1.164.3.2.3.2.16.3.1.12DisplayStringread-createThis is the second local subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
STR prtIsdnDirectoryRemoteAddr21.3.6.1.4.1.164.3.2.3.2.16.3.1.13DisplayStringread-createThis is the second remote address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank(20 characters)
STR prtIsdnDirectoryRemoteSubAddr21.3.6.1.4.1.164.3.2.3.2.16.3.1.14DisplayStringread-createThis is the second remote subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
prtLogicalCnfg1.3.6.1.4.1.164.3.2.3.2.17
prtLogicalCnfgTable1.3.6.1.4.1.164.3.2.3.2.17.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtLogicalCnfgEntry1.3.6.1.4.1.164.3.2.3.2.17.1.1not-accessibleAn entry in table.
I32 prtLogicalCnfgIdx1.3.6.1.4.1.164.3.2.3.2.17.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtLogicalSltIdx1.3.6.1.4.1.164.3.2.3.2.17.1.1.2INTEGERread-onlySlot Index. For ISDN BRI Ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6).
I32 prtLogicalPrtIdx1.3.6.1.4.1.164.3.2.3.2.17.1.1.3Integer32read-onlyThis attribute indicates a unique port number. This port number should be an internal port number: inPrt1(101)->inPrt50(150), linkSel1(200)->linkSel50(250), encaps1(300)-> encaps50(350), huntGr1(101) -> huntGr10(110).
INT prtLogicalConnect1.3.6.1.4.1.164.3.2.3.2.17.1.1.4INTEGERread-createThis attribute indicates whether the port should be considered in any of the mux algorithms.
INT prtLogicalFunction1.3.6.1.4.1.164.3.2.3.2.17.1.1.5INTEGERread-createThis parameter defines the function of the relevant channel.
ROW prtLogicalRowStatus1.3.6.1.4.1.164.3.2.3.2.17.1.1.6RowStatusread-createThis parameter allows the NMS to create/delete logical ports. The only possible supported RowStatus vaules are active (1) and destroy (6).
linkSelectorCnfgTable1.3.6.1.4.1.164.3.2.3.2.17.2not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
linkSelectorCnfgEntry1.3.6.1.4.1.164.3.2.3.2.17.2.1not-accessibleAn entry in table.
I32 linkSelectorCnfgIdx1.3.6.1.4.1.164.3.2.3.2.17.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT linkSelectorSltIdx1.3.6.1.4.1.164.3.2.3.2.17.2.1.2INTEGERread-onlySlot Index
I32 linkSelectorPrtIdx1.3.6.1.4.1.164.3.2.3.2.17.2.1.3Integer32read-onlyThis attribute indicates a unique port number. This port number should be internal port number: higher or equal to linkSeL1(201).
I32 linkSelectorMaxIdleTime1.3.6.1.4.1.164.3.2.3.2.17.2.1.4Integer32read-writeMove to higher prioritized connected link after this period of seconds of silence on the current link. 0=move immediately to higher prioritized connected link. UNIT is seconds.
INT linkSelectorMode1.3.6.1.4.1.164.3.2.3.2.17.2.1.5INTEGERread-writeIf the link selector is in mode: backup(2)=then the link with the lower priority will be used in case of failure of the higher priority link, bod(3)=bandwidth on demand or dynamic bandwidth allocation means that links with lower priority will be used whenever additional bandwidth is required.
INT linkSelectorRevert1.3.6.1.4.1.164.3.2.3.2.17.2.1.6INTEGERread-writeIf the link selector is in mode backup: auto(2)=return automatically to Main link when it is OK. manual(3)=stays connected to backup link.
I32 linkSelectorMinBUSession1.3.6.1.4.1.164.3.2.3.2.17.2.1.7Integer32read-writeMinimum duration of a backup session before returning to Main Link. Relevant in Backup Mode and when Revert is auto(2). Value 255 is for NEVER which means never return to Main Link. UNIT is minutes.
linkSelectorPLinkTable1.3.6.1.4.1.164.3.2.3.2.17.3not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
linkSelectorPLinkEntry1.3.6.1.4.1.164.3.2.3.2.17.3.1not-accessibleAn entry in table.
I32 pLinkCnfgIdx1.3.6.1.4.1.164.3.2.3.2.17.3.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT pLinkSltIdx1.3.6.1.4.1.164.3.2.3.2.17.3.1.2INTEGERread-onlySlot Index
I32 pLinkPrtIdx1.3.6.1.4.1.164.3.2.3.2.17.3.1.3Integer32read-onlyThis attribute indicates a unique port number. This port number should be the link selector number.
I32 pLinkIdx1.3.6.1.4.1.164.3.2.3.2.17.3.1.4Integer32read-onlyThis index is the row number.
INT pLinkSlotNu1.3.6.1.4.1.164.3.2.3.2.17.3.1.5INTEGERread-writeThe slot of the prioritized link. For ISDN BRI ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6).
I32 pLinkPortNu1.3.6.1.4.1.164.3.2.3.2.17.3.1.6Integer32read-writeThe port of the prioritized link. Value 100 is for noConnect.
I32 pLinkPrioNu1.3.6.1.4.1.164.3.2.3.2.17.3.1.7Integer32read-writeThe priority of the prioritized link. MIN=1...., MAX=8.
INT pLinkVRate1.3.6.1.4.1.164.3.2.3.2.17.3.1.8INTEGERread-writeThe rate to use with this link.
prtFrPlusCnfg1.3.6.1.4.1.164.3.2.3.2.18
prtFrPlusCnfgTable1.3.6.1.4.1.164.3.2.3.2.18.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry.
prtFrPlusCnfgEntry1.3.6.1.4.1.164.3.2.3.2.18.1.1not-accessibleAn entry in table.
I32 prtFrPlusCnfgIdx1.3.6.1.4.1.164.3.2.3.2.18.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
INT prtFrPlusSltIdx1.3.6.1.4.1.164.3.2.3.2.18.1.1.2INTEGERread-onlySlot Index. For ISDN BRI Ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6).
I32 prtFrPlusPrtIdx1.3.6.1.4.1.164.3.2.3.2.18.1.1.3Integer32read-onlyThis attribute indicates a unique port number. This port number should be: - for ISDN cards: inPrt1(101)->inPrt50(150) - for MHS1 card : exPrt1(1) - for MHS3, MLS3 cards: exPrt1(1)->exPrt3(3) - for MLS6 cards: exPrt1(1)->exPrt6(6).
OCT prtFrPlusNotSegmentedPriorities1.3.6.1.4.1.164.3.2.3.2.18.1.1.4OCTET STRINGread-writeThis parameter is relevant only for FR+ protocol and asks the MXcess NOT to segment data with specified priorities: from LSB: bit 1 is for priority 1, bit 2 is for priority 2, .... till bit 7 for priority 7. - a priority selected to be segmented : its bit will be '0' - a priority not to be segmented : its bit will be '1' Default is 00000000; i.e, segment all priorities.
prtMl4Cnfg1.3.6.1.4.1.164.3.2.3.2.19
prtMl4CnfgTable1.3.6.1.4.1.164.3.2.3.2.19.1not-accessibleThis is an extension table for MTML-4 card parameters.
prtMl4CnfgEntry1.3.6.1.4.1.164.3.2.3.2.19.1.1not-accessibleAn entry in table.
I32 prtMl4CnfgIdx1.3.6.1.4.1.164.3.2.3.2.19.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
INT prtMl4SltIdx1.3.6.1.4.1.164.3.2.3.2.19.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the module is inserted.
INT prtMl4PrtIdx1.3.6.1.4.1.164.3.2.3.2.19.1.1.3INTEGERread-onlyThis attribute indicates a unique port number.
INT prtMl4SigProfile1.3.6.1.4.1.164.3.2.3.2.19.1.1.4INTEGERread-writeThis object indicates the Signaling Profile of the port. none - when the Frame is G732N (no MF) or Unframed. p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4 p5 = profile 5 perTS = when Signaling Profile is selected per TS.
INT prtMl4CGA1.3.6.1.4.1.164.3.2.3.2.19.1.1.5INTEGERread-writeThis object selects the method used to signal the CGA state to the other end, through the main link. 'none' - non-transparent mode. When one of the links (main) will be in Out Of Service state, both 'Data/Voice Oos' and 'Oos' will be transmitted to the other end. 'trans' - when one of the links (main) will be in Out Of Service state, 'Data/Voice Oos' will be transmitted to the other end. 'full' - fully-transparent mode. When one of the links (main) will be in Out Of Service state, neither 'Data/Voice Oos' nor 'Oos' will be transmitted to the other end.
INT prtMl4Oos1.3.6.1.4.1.164.3.2.3.2.19.1.1.6INTEGERread-write'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. 'busyIdle' = MK_SP = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. 'idleBusy' = SP_MK = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0
OCT prtMl4VoiceOos1.3.6.1.4.1.164.3.2.3.2.19.1.1.7OCTET STRINGread-writeVoice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
OCT prtMl4DataOos1.3.6.1.4.1.164.3.2.3.2.19.1.1.8OCTET STRINGread-writeData Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
INT prtMl4Service1.3.6.1.4.1.164.3.2.3.2.19.1.1.9INTEGERread-writeLink Service. leasedLine - usual TDM interface. v51 - V5.1 interface. v52Master - V5.2 Link to Local Exchange. v52Slave - a ML that is transferred to the v52Master.
IP prtMl4IpAddress1.3.6.1.4.1.164.3.2.3.2.19.1.1.10IpAddressread-writeIP Address of the port.
IP prtMl4IpMask1.3.6.1.4.1.164.3.2.3.2.19.1.1.11IpAddressread-writeIP subnet mask of the port.
INT prtMl4SignalingMode1.3.6.1.4.1.164.3.2.3.2.19.1.1.12INTEGERread-writeRefers to the signaling mode of the port (or framer module). notApplicable(1)- means that no framer is needed for this port (no signaling), or that this object is not relevant. cas(2) means Channel Associated Signaling. Used for E1 Links. ccs(3) is the Common Channel Signaling (the signaling is not within the channels time slot - a TS for signaling is used). robbedBit(4) is a method implementing 7 bits for the voice and 1 bit dedicated for signaling. Used for T1 Links. other (5)- Signaling generally exists though not specifically according to one of the values listed ; this port uses a framer in this case.
INT prtMl4EchoCanceler1.3.6.1.4.1.164.3.2.3.2.19.1.1.13INTEGERread-writeEcho canceler activation.
INT prtMl4OosErrorSource1.3.6.1.4.1.164.3.2.3.2.19.1.1.14INTEGERread-writeOOS (Out-of-Service) Error Source. This object is applicable for T1 ports only.
I32 prtMl4OosEntryThreshold1.3.6.1.4.1.164.3.2.3.2.19.1.1.15Integer32read-writeThis object defines the number of Errors per Second that determine the minimum unacceptable noise level. This value will be the Entry Threshold to the OOS (Out-of-Service) state. This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4). 0=notApplicable.
I32 prtMl4OosExitThreshold1.3.6.1.4.1.164.3.2.3.2.19.1.1.16Integer32read-writeThis object defines the number of consecutive Error-Free-Seconds before going from OOS state to Normal state. This value will be the Exit Threshold from the OOS (Out-of-Service) state. Units=seconds This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4). 0=notApplicable.
I32 prtMl4LogicalLinkId1.3.6.1.4.1.164.3.2.3.2.19.1.1.17Integer32read-writeThis object defines for a V5.2 Master ML the Logical Link Id. Valid values are: 0..256. NA=257.
I32 prtMl4DedicatedTs1.3.6.1.4.1.164.3.2.3.2.19.1.1.18Integer32read-writeA unique number to identify Dedicated TS of the E1 port (V5.2). It is applicable only when prtMl4Service=v52Slave and prtExPh1MlInbandMng selected is dedicatedTs, dedicatedPpp or dedicatedFr. 1..31 - Dedicated TS of E1 255 - notApplicable Other values are invalid.
INT prtMl4RemCrc1.3.6.1.4.1.164.3.2.3.2.19.1.1.19INTEGERread-writeThis object indicates whether the E1 of the Remote device connected to this E1 port, will have CRC-4 or not.
INT prtMl4CrossConnectLevel1.3.6.1.4.1.164.3.2.3.2.19.1.1.20INTEGERread-writeThis object indicates whether the cross connect is on DS1 or DS0 (time-slots) level. When cross connect level is ds1, Destination Slot is indicated by prtGenCnfgLinkToSlot, Destination Port is indicated by prtGenCnfgLinkToPort. For Unframed Line Type, cross connect level can be either notApplicable (NC=not connected) or DS1. Otherwise, default value is ds0.
INT prtMl4PppEchoFailDetection1.3.6.1.4.1.164.3.2.3.2.19.1.1.21INTEGERread-writeThis object indicates whether the PPP Echo is taken into account for its Fail Detection. This object is relevant when Inband Mng between devices is Dedicated TS PPP. Default=Disable. Enable - will be selected mainly when a T1/E1 Ring exists and between 2 adjacent Ring devices there is another device or Net, that causes these Ring devices not to sense that the PPP connection between them is lost. In this case, Echo Request should be initiated by the port.
prtAcmCnfg1.3.6.1.4.1.164.3.2.3.2.20
prtAcmCnfgTable1.3.6.1.4.1.164.3.2.3.2.20.1not-accessibleThis is a table for ACM port parameters.
prtAcmCnfgEntry1.3.6.1.4.1.164.3.2.3.2.20.1.1not-accessibleAn entry in table.
I32 prtAcmCnfgIdx1.3.6.1.4.1.164.3.2.3.2.20.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
INT prtAcmSltIdx1.3.6.1.4.1.164.3.2.3.2.20.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the module is inserted.
INT prtAcmPrtIdx1.3.6.1.4.1.164.3.2.3.2.20.1.1.3INTEGERread-onlyThis attribute indicates a unique port number.
INT prtAcmConnect1.3.6.1.4.1.164.3.2.3.2.20.1.1.4INTEGERread-writeThis attribute indicates whether the port should be connected or not. Only a connected port can perform activity.
INT prtAcmActiveState1.3.6.1.4.1.164.3.2.3.2.20.1.1.5INTEGERread-writeThis attribute indicates the Electric Active State of the port.
STR prtAcmAlrString1.3.6.1.4.1.164.3.2.3.2.20.1.1.6DisplayStringread-writeAlarm string selected by user for the Inbound ports. This object is applicable only for the Inbound Ports: ext-5..ext-12. For the Outbound Ports (ext-1..ext-4), the size of this string will be 0.
prtE2Cnfg1.3.6.1.4.1.164.3.2.3.2.21
prtE2CnfgTable1.3.6.1.4.1.164.3.2.3.2.21.1not-accessibleThis is a table for E2 port parameters.
prtE2CnfgEntry1.3.6.1.4.1.164.3.2.3.2.21.1.1not-accessibleAn entry in table.
I32 prtE2CnfgIdx1.3.6.1.4.1.164.3.2.3.2.21.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
INT prtE2SltIdx1.3.6.1.4.1.164.3.2.3.2.21.1.1.2INTEGERread-onlyThis attribute indicates a unique slot position where the module is inserted.
INT prtE2PrtIdx1.3.6.1.4.1.164.3.2.3.2.21.1.1.3INTEGERread-onlyThis attribute indicates a unique port number.
INT prtE2Connect1.3.6.1.4.1.164.3.2.3.2.21.1.1.4INTEGERread-writeThis attribute indicates whether the port should be connected or not. Only a connected port can perform activity.
INT prtE2MngOnNationalBit1.3.6.1.4.1.164.3.2.3.2.21.1.1.5INTEGERread-writeThis attribute indicates whether National Bit will be used for Management or not.
prtLanWanCnfg1.3.6.1.4.1.164.3.2.3.2.22
prtLanWanCnfgTable1.3.6.1.4.1.164.3.2.3.2.22.1not-accessibleThis is a table for Lan-Wan port parameters.
prtLanWanCnfgEntry1.3.6.1.4.1.164.3.2.3.2.22.1.1not-accessibleAn entry in table.
I32 prtLanWanCnfgIdx1.3.6.1.4.1.164.3.2.3.2.22.1.1.1Integer32not-accessibleThis object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
INT prtLanWanSltIdx1.3.6.1.4.1.164.3.2.3.2.22.1.1.2INTEGERnot-accessibleThis object indicates a unique slot position where the module is inserted.
I32 prtLanWanPrtIdx1.3.6.1.4.1.164.3.2.3.2.22.1.1.3Integer32not-accessibleThis object indicates a unique number to identify a port in a specific card. Generally, for MP-210X/2200, the Port Index will be according to the external/internal port number: - exPrtX : X - inPrtX : 100 + X For FCD-155, refer to device specification
INT prtLanWanMode1.3.6.1.4.1.164.3.2.3.2.22.1.1.4INTEGERread-writeThis object determines the working mode of this port. For FCD155, layer3SubnetSwitch is not applicable
I32 prtLanWanDestIf1.3.6.1.4.1.164.3.2.3.2.22.1.1.5Integer32read-writeThis object determines the Destination Interface for the frames received by this port. - Switching Table = 100 (it means that the destination interface will be determined by the Switching Table) - inPrtX (internal-X port): 100 + X . For FCD-155 this object is not applicable =0
INT prtLanWanEgressVlanMode1.3.6.1.4.1.164.3.2.3.2.22.1.1.6INTEGERread-writeThis object determines what to do with the VLAN frames that exit via the WAN side of the port. This object is not applicable when prtLanWanMode=l3SubnetSwitch(4).
INT prtLanWanL2Protocol1.3.6.1.4.1.164.3.2.3.2.22.1.1.7INTEGERread-writeL2 Protocol. When prtLanWanMode=l3SubnetSwitch(4), the only valid value is ppp(3).
I32 prtLanWanStpPriority1.3.6.1.4.1.164.3.2.3.2.22.1.1.8Integer32read-writeThe value of the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID.
I32 prtLanWanStpCost1.3.6.1.4.1.164.3.2.3.2.22.1.1.9Integer32read-writeThe contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN.
INT prtLanWanToLanVlanMode1.3.6.1.4.1.164.3.2.3.2.22.1.1.10INTEGERread-writeThis object determines what to do with the VLAN frames that come from WAN side of the port and exit towards one of the LAN ports. This object is applicable only when prtLanWanDestIf=100 or 101 (Switching Table or inPrt1).
I32 prtLanWanVlanId1.3.6.1.4.1.164.3.2.3.2.22.1.1.11Integer32read-writeThis is the VLAN Id attached to a frame, when the relevant Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is tag or doubleTag. 0=not applicable.
I32 prtLanWanVlanPriority1.3.6.1.4.1.164.3.2.3.2.22.1.1.12Integer32read-writeThis is the VLAN Priority attached to a frame, when the relevant Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is tag or doubleTag. Valid values: 0..7 255=not applicable.
I32 prtLanWanMtu1.3.6.1.4.1.164.3.2.3.2.22.1.1.13Integer32read-writeThe size of the largest packet which can be sent/received on the interface, specified in octets. Valid values change per device. 0=not applicable.
INT prtLanWanVlanType1.3.6.1.4.1.164.3.2.3.2.22.1.1.14INTEGERread-writeThis oject indicates type of VLAN this port is assigned to. Port Base Vlan parameters are defined by objects under radBridgePortBaseVlan
dacsMux1.3.6.1.4.1.164.3.3
dacsMuxEvents1.3.6.1.4.1.164.3.3.0The events for DACS MUX.
NTF sanityCheckTrap1.3.6.1.4.1.164.3.3.0.1This trap is sent after a data base download attempt. It returns the sanity result status and the configuration no.checked.
NTF dacsMuxAlarmsTrap1.3.6.1.4.1.164.3.3.0.2This trap is sent when an alarm occurs.
NTF mdlConnectTrap1.3.6.1.4.1.164.3.3.0.3This trap is sent when a card is removed.
NTF sysAlrStatusTrap1.3.6.1.4.1.164.3.3.0.4This trap is sent upon any change in the value of any of the variables.
NTF sysStatusChangedTrap1.3.6.1.4.1.164.3.3.0.5This trap is sent when Leds status is changed.
NTF cnfgUpdateTrap1.3.6.1.4.1.164.3.3.0.6This trap is sent upon change of the active Configuration DB.
NTF sysRedundancyStatusTrap1.3.6.1.4.1.164.3.3.0.7The trap is sent upon change in Redundancy Status.
NTF sysRedundancyActiveCardTrap1.3.6.1.4.1.164.3.3.0.8The trap is sent upon change of Active Main/CL Card.
NTF sysRedundancyActivePortTrap1.3.6.1.4.1.164.3.3.0.9The trap is sent upon change of Active Port of Redundancy Group.
systemDacsMux1.3.6.1.4.1.164.3.3.1
sysSa1.3.6.1.4.1.164.3.3.1.1
I32 sysSaSwchStatus1.3.6.1.4.1.164.3.3.1.1.1Integer32read-onlyThis object indicates the status of the switches on the SA unit. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits. For SMODs products see modem's specification. For DXC product see the following: There are 4 switches: bit 0 SP-PAR (LSB) '1' - Default parameters bit 1 PSWRD '1' - Password=default '0' - Password=user selected bit 2 DB-INIT '1' - DB initiated with default '0' - DB initiated with NVRAM contents bit 3 PC-SP (MSB) '1' - Management by terminal only '0' - Management by NMS Example: If SP-PAR and PSWRD bits are set ('1'), the value will be 3 (2**1 + 2**0). When the status of the switches is unknown, the value of this object will be 255.
STR sysSaSwRevision1.3.6.1.4.1.164.3.3.1.1.2DisplayStringread-onlyThis object indicates the Software revision of the system.
STR sysSaHwVersion1.3.6.1.4.1.164.3.3.1.1.3DisplayStringread-onlyThis object indicates the Hardware version of the system.
I32 sysSaPorts1.3.6.1.4.1.164.3.3.1.1.4Integer32read-onlyThis object indicates the ports that are present in the system. Each possible port is represented by a bit. The value of this object is a sum of 2**n, n=number of bits. '1' - means that the port exists '0' - means that the port does not exist For detailed bit assignment, see product's spec. Bit 0 = LSB When this object is not relevant, the value will be 0. In some cases, this object may represent ports configuration of the system AND its far-end unit.
I32 sysSaReadSwch1.3.6.1.4.1.164.3.3.1.1.5Integer32read-writeThis object indicates wether the configuration will be read from the DIP switches on the SA (stand alone) unit. Each switch is represented by a bit. If the bit is 1: the configuration will be read from the HW switch position. If the bit is 0: the configuration will be read from the SW user configuration. The DIP switches are different in each of the RAD devices. In the Tiny Router (starting from the LSB) the following switches exist: Bit 0: WAN Loop Bit 1: LAN Full Duplex (When LAN AUI connector, it is SQE) Bit 2: PPP (When WAN 4 Wire connector, it is LONG) Bit 3: IP Learn
INT sysSaBuActivePort1.3.6.1.4.1.164.3.3.1.1.6INTEGERread-onlyThis object shows through which port the traffic is flowing (the current Active Port) when the Backup mechanism exists. When No Backup exists in the device, the value should be: notApplicable(1).
sysHub1.3.6.1.4.1.164.3.3.1.2
sysChas1.3.6.1.4.1.164.3.3.1.2.1
I32 chassTotalNoOfSlt1.3.6.1.4.1.164.3.3.1.2.1.1Integer32read-onlyThis object indicates the number of physical slots in the Hub chassis.
I32 chassTotalNoOfIoSlt1.3.6.1.4.1.164.3.3.1.2.1.2Integer32read-onlyThis object indicates the total number of physical IO slots in the chassis, (not all slots must be occupied and active).
I32 chassTotalNoOfPsSlt1.3.6.1.4.1.164.3.3.1.2.1.3Integer32read-onlyThis object indicates the number of physical Power Supply slots in the chassis.
I32 chassTotalNoOfClSlt1.3.6.1.4.1.164.3.3.1.2.1.4Integer32read-onlyThis object indicates the number of physical Common Logic slots in the chassis.
I32 chassTotalNoOfMlSlt1.3.6.1.4.1.164.3.3.1.2.1.5Integer32read-onlyThis object indicates the number of physical Main Link slots in the chassis (Kmux).
sysDcl1.3.6.1.4.1.164.3.3.1.2.2
sysDclTable1.3.6.1.4.1.164.3.3.1.2.2.1not-accessibleAll the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
sysDclEntry1.3.6.1.4.1.164.3.3.1.2.2.1.1not-accessibleAn entry in table.
I32 sysDclCnfgIdx1.3.6.1.4.1.164.3.3.1.2.2.1.1.1Integer32read-onlyThis object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg. This object is identical for all the configurations (1..255). Only the TmpCnf(255) might have a different value. For devices that work on line with NMS (no Temp configuration in NMS), Get and Set will be performed with index value of sysDclCnfgIdx = 1.
INT sysDclRedundancy1.3.6.1.4.1.164.3.3.1.2.2.1.1.2INTEGERread-writeDCL redundancy desired state.
INT sysDclActiveCl1.3.6.1.4.1.164.3.3.1.2.2.1.1.3INTEGERread-writeActive desired DCL. When 'auto' is selected, the system automatically selects the active DCL.
I32 sysDclFlipDelay1.3.6.1.4.1.164.3.3.1.2.2.1.1.4Integer32read-writeIf one DCL flip occurred and a second one should be performed, the time from the previous flip is checked. If the time is shorter than the delay specified here, the system should delay the flip operation until time reaches the specified delay. For DXC the values are 1 minute to 4 minutes (1..4). For Optimux-155-1 and Optimux-155-3 the values are: 0...60 Sec. 0 means No Delay.
INT sysDclFlipUponStnClk1.3.6.1.4.1.164.3.3.1.2.2.1.1.5INTEGERread-writeThis object allows user to decide (yes/no) if Agent should Flip from one DCL card to another, when there is Station Clock Fail in the Online DCL card.
I32 sysDclChFailThreshold1.3.6.1.4.1.164.3.3.1.2.2.1.1.6Integer32read-writeThis object indicates the number of failed channels that will trigger the redundancy procedure.
OCT sysDclChPriority1.3.6.1.4.1.164.3.3.1.2.2.1.1.7OCTET STRINGread-writeThis object indicates the Priority for all the channels in the Main Access (Common Logic) card. Each channel is represented by 1 bit. The order of the bits in each byte is from Right to Left (LSB Bit to MSB) starting from BIT 0: 7 6 5 4 3 2 1 0 Channel no. 1 is represented by bit 0. Channel no. 2 is represented by bit 1. Channel no. n is represented by bit n-1. The value of the bit shows the priority. For bit value = 1, Priority = High. For bit value = 0, Priority = Low.
INT sysDclConfigDownloadSrc1.3.6.1.4.1.164.3.3.1.2.2.1.1.8INTEGERread-writeIn case of mismatch between the 2 CL card's configuration, the user can decide which card has the suitable configuration. The selected configuration will be downloaded from card A to card B if the value is dclA(2) or from card B to card A if the value is dclB(3). off(1) is used by part of the devices. In this case, after operation ends - value should be automatically set to off(1), which is the default state.
INT sysDclSwDownloadSrc1.3.6.1.4.1.164.3.3.1.2.2.1.1.9INTEGERread-writeIn case of mismatch between the 2 CL card's software, the user can decide which card has the suitable SW. The selected SW will be downloaded from card A to card B if the value is dclA(2) or from card B to card A if the value is dclB(3). off(1) is used by part of the devices. In this case, after operation ends - value should be automatically set to off(1), which is the default state.
BIT sysDclRedundancyStatus1.3.6.1.4.1.164.3.3.1.2.2.1.1.10Bitsread-onlyBit map representing current Redundancy Status. bit 0 - Indicates mismatch between the 2 CL cards' Configuration bit 1 - Indicates mismatch between the 2 CL cards' Software. bit 2 - Indicates CL card A Absence. bit 3 - Indicates CL card B Absence. bit 4 - Indicates Loss of Communication between the 2 CL cards. bit 5 - Indicates mismatch between the 2 CL cards' Hardware. bit 6 - Indicates Configuraton update is in process. bit 7 - Indicates Software update is in process.
INT sysDclOnline1.3.6.1.4.1.164.3.3.1.2.2.2INTEGERread-onlyThe active Dcl card of the agent.
sysDclCopyDbTable1.3.6.1.4.1.164.3.3.1.2.2.3not-accessibleThis table enables to copy a cofiguration from the Offline Dcl to the Online Dcl.
sysDclCopyDbEntry1.3.6.1.4.1.164.3.3.1.2.2.3.1not-accessibleAn entry in table.
I32 sysDclCopyDbIdx1.3.6.1.4.1.164.3.3.1.2.2.3.1.1Integer32read-onlyThis object indicates the Idx of the Cnfg(1..255) being accessed.
INT sysDclCopyDbCmd1.3.6.1.4.1.164.3.3.1.2.2.3.1.2INTEGERread-writeWhen this command is sent to the agent, on(3), the Database specified (Db Idx), will be copied from the Offline Dcl to the Online Dcl. Afterwards the value of this object will automatically change to off(2).
INT sysDclFlipCmd1.3.6.1.4.1.164.3.3.1.2.2.4INTEGERread-writeWhen the 'flip(3)' command is received by Agent, it will flip (switch) between Offline Dcl and Online Dcl cards. Afterwards the value of this object will automatically change to off(2).
sysStatus1.3.6.1.4.1.164.3.3.1.3
INT sysSDateFormat1.3.6.1.4.1.164.3.3.1.3.1INTEGERread-writeThis object indicates the date and time format used for the sysSDateAndTimeCmd and for the alarm buffer report.
STR sysSDateCmd1.3.6.1.4.1.164.3.3.1.3.2DisplayStringread-writeThis object indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the sysSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent. * For KM-2100 V1 and FCD-T1/E1 - the string should contain '/' signs between day, month and year. Example: 12/08/1998. * For DXC and rest of the products - the string should contain '-' signs between day, month and year. Example: 12-08-1998. The day value will be in the range: 1..31. The month value will be in the range: 1..12. The year value will be in the range: 1996..2050 for products supporting the '-' format.
STR sysSTimeCmd1.3.6.1.4.1.164.3.3.1.3.3DisplayStringread-writeThis object indicates the current time as it is known by the agent using its own real-time clock. This parameter can be set for time synchronization between the NMS and the Agent. The string should contain ':' signs between hour, minute and second. Example: 11:05:58.
I32 sysSActiveCnfg1.3.6.1.4.1.164.3.3.1.3.4Integer32read-onlyThis object specifies the configuration number, that is currently active and running.
I32 sysSEditCnfg1.3.6.1.4.1.164.3.3.1.3.5Integer32read-onlyThis object indicates the unique configuration number that is currently loaded into the tmp working space for manipulation and update operations. Value of 255 means no config. is under editing process.
INT sysSEditBy1.3.6.1.4.1.164.3.3.1.3.6INTEGERread-onlyThis entry indicates which MMI application is working on the edited config. The editing phase starts at the first modify operation and ends after a load operation.
INT sysSClkSrc1.3.6.1.4.1.164.3.3.1.3.7INTEGERread-onlyThis entry indicates the source of the system clock.
INT sysSAlrStatus1.3.6.1.4.1.164.3.3.1.3.8INTEGERread-onlyIndicates the current alarm state only for system level. This object will be : - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
INT sysSAlrStatusAll1.3.6.1.4.1.164.3.3.1.3.9INTEGERread-onlyIndicates the current alarm state including all levels: system, card, port. - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
INT sysSTestStatus1.3.6.1.4.1.164.3.3.1.3.10INTEGERread-onlyIndicates the current test status (for all levels: system, card, port). This attribute will be set to: - on(3): when there is at least one test in progress on the system/card/port otherwise the value will be off(2).
INT sysSSanityCheckStatus1.3.6.1.4.1.164.3.3.1.3.11INTEGERread-onlyUpon completion of the Sanity Check process on the TmpCnfg this object will be set to: - fail(2): when there is at least one error (which is not just a warning) encountered otherwise, - warning(3): when there are only warnings otherwise, - ok(4). The value should be unknown(1), if the TmpCnfg was changed after the last Sanity check.
I32 sysSNoOfSanityCheckErr1.3.6.1.4.1.164.3.3.1.3.12Integer32read-onlyThis object indicates the number of errors/warnings discovered by the last Sanity Check process.
sysSErrListTable1.3.6.1.4.1.164.3.3.1.3.13not-accessibleA table.
sysSErrListEntry1.3.6.1.4.1.164.3.3.1.3.13.1not-accessibleAn entry in table.
INT sysSErrType1.3.6.1.4.1.164.3.3.1.3.13.1.1INTEGERread-onlyThe errors are recorded in the agent, in two separate lists, according to their type: error or warning.
I32 sysSErrIdx1.3.6.1.4.1.164.3.3.1.3.13.1.2Integer32read-onlyUnique index number to identify an entry in the error or warning list . The maximum value cannot exceed the value of 'sysSNoOfSanityCheckErr' (actually, the sum of the Errors list max. index and the Warning list max. index should equal the value of'sysSNoOfSanityCheckErr').
STR sysSErrDescription1.3.6.1.4.1.164.3.3.1.3.13.1.3DisplayStringread-onlyThis object is a full text description of the sanity check error including error code, IO slot and port numbers related to the code .
I32 sysSMaxNoOfCnfg1.3.6.1.4.1.164.3.3.1.3.14Integer32read-onlyMaximum number of configurations that can be defined and stored in the DACS agent. If the DACS agent has a large capacity, the maximum will be limited to 254.
I32 sysSSelfTestResult1.3.6.1.4.1.164.3.3.1.3.15Integer32read-onlyThe test is performed by the active Common Logic card. The result will be a sum of 2**n according to the following bit convention: For DXC: bit 0 Database 1 Checksum Error (LSB) bit 1 Database 2 Checksum Error bit 2 I/O Expander Error bit 3 Counter Error bit 4 Matrix DPR Error bit 5 PS-A 5 Volt Error bit 6 PS-A 12 Volt Error bit 7 PS-B 5 Volt Error bit 8 PS-B 12 Volt Error bit 9 EPROM Failure For FCD: bit 0 I/O Expander Error (LSB) bit 1 Counter Error bit 2 EPROM Failure bit 3 Illegal Sys Config bit 4 SFIFO bit 5 EPIC Failure (ISDN) bit 6 XL Flash Fail -- for MSDSL interface bit 7 XL MITEL Fail -- for MSDSL interface bit 8 XL Framer Fail -- for MSDSL interface bit 9 XL DSP Fail -- for MSDSL interface For LRS52 - refer to product's spec When a bit is ('1'), the error exists. When NO ERROR is encountered, this object's value will be 0.
INT sysSRelayState1.3.6.1.4.1.164.3.3.1.3.16INTEGERread-onlyIndicates the current state of the alarm relay. notApplicable - for agents that do not support this object.
INT sysSInvertedAlr1.3.6.1.4.1.164.3.3.1.3.17INTEGERread-onlyIndicates if there is any Inverted alarm at any level of the system (sys, card, port). notApplicable - for agents that do not support this object.
sysSRdnFlipTable1.3.6.1.4.1.164.3.3.1.3.18not-accessibleThis table includes all the Flip events due to I/O Redundancy since last Clear command of this table.
sysSRdnFlipEntry1.3.6.1.4.1.164.3.3.1.3.18.1not-accessibleAn entry in table.
I32 sysSRdnFlipIdx1.3.6.1.4.1.164.3.3.1.3.18.1.1Integer32read-onlyUnique index number to identify an entry in the Redundancy Flip list.
INT sysSRdnFlipSlot1.3.6.1.4.1.164.3.3.1.3.18.1.2INTEGERread-onlyThe slot number from which Flip was performed.
I32 sysSRdnFlipPort1.3.6.1.4.1.164.3.3.1.3.18.1.3Integer32read-onlyThe port number from which Flip was performed. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 100=notApplicable (when Redundancy is at card level).
STR sysSRdnFlipCause1.3.6.1.4.1.164.3.3.1.3.18.1.4DisplayStringread-onlyThe last cause that caused the Flip from the Slot (Port) of sysSRdnSlot, sysSRdnPort.
STR sysSRdnFlipDate1.3.6.1.4.1.164.3.3.1.3.18.1.5DisplayStringread-onlyFlip event Date. The format will be the one selected by user for sysSDateFormat.
STR sysSRdnFlipTime1.3.6.1.4.1.164.3.3.1.3.18.1.6DisplayStringread-onlyFlip event Time. The format will be hh:mm:ss.
INT sysSRdnFlipTableClearCmd1.3.6.1.4.1.164.3.3.1.3.19INTEGERread-writeThis command, when Set to 'on', clears the Redundancy Flip table (sysSRdnFlipTable). After clear is performed, the agent will turn the value to 'off' automatically.
OID sysSRdnFlipCmd1.3.6.1.4.1.164.3.3.1.3.20OBJECT IDENTIFIERread-writeThis object enables the user to send a command to the Agent, to Flip from a current Online IO card to its Redundant card. The value sent will be an Object Identifier of an entry in the sysCRdnTable. This entry defines the Redundant couple of Slots on which the Flip is applied. Setting this object, will cause the Agent to Flip from current Online card to its Redundant card. This manual flip command is applicable only for entries having Redundancy Mode=Y Cable. For Vmux: This command will cause flipping from Secondary or Third Link to the Primary Link. If the active link is the primary link, the agent will flip to the secondary link. The value sent will be the Object Identifier of the following Table: agnCBuMlTable. Agent will send the value 0 for Get.
sysSBusTable1.3.6.1.4.1.164.3.3.1.3.21not-accessibleThis table includes data and status about the internal DXC BUS.
sysSBusEntry1.3.6.1.4.1.164.3.3.1.3.21.1not-accessibleAn entry in table.
I32 sysSBusPortIdx1.3.6.1.4.1.164.3.3.1.3.21.1.1Integer32read-onlyThe DXC BUS port number: - first two digits will be: (IO slot number+10) - last one/two digits will be the Bus port number, in odd numbers: port1 = 1 port2 = 3 Example: port2 of IO slot 11 will be: 213.
INT sysSBusStatus1.3.6.1.4.1.164.3.3.1.3.21.1.2INTEGERread-onlyThe Status of sysSBusPortIdx. free - not used physical - captured by the port of the card physically installed virtual - captured virtually by another port. Example: DIM port (by Destination) or by Transparent T3/E3 port.
I32 sysSBusCapturePort1.3.6.1.4.1.164.3.3.1.3.21.1.3Integer32read-onlyThe Port that Captured the sysSBusPortIdx. - if sysSBusStatus=free, the value will be 'none'=0 - else, if sysSBusStatus=fixed, the value will be: sysSBusPortIdx - else, the value will be according to the port index that captured this Bus Port (according to DXC port index convention): - xx1, xx3, xx11, xx13, xx31, xx33, xx2..xx56(even numbers) - xx = (IO slot number+10)
I32 sysSBusUtilization1.3.6.1.4.1.164.3.3.1.3.21.1.4Integer32read-onlyUtilization of sysSBusPortIdx resources, in percent [%].
sysSRdnCmdTable1.3.6.1.4.1.164.3.3.1.3.22not-accessibleThis table includes commands used for IO Redundancy.
sysSRdnCmdEntry1.3.6.1.4.1.164.3.3.1.3.22.1not-accessibleAn entry in table.
INT sysSRdnEnforcedChannel1.3.6.1.4.1.164.3.3.1.3.22.1.1INTEGERread-writeThis is a command to override all switching considerations and enforce use of primary/ secondary connection only. noEnforcement - cancels the state of override and goes back to usual switching considerations. Default = noEnforcement(2).
INT sysSRdnLockFlip1.3.6.1.4.1.164.3.3.1.3.22.1.2INTEGERread-writeThis is a command to lock the Redundancy flip for this redundancy couple. Default = off(2).
INT sysSRdnManualFlip1.3.6.1.4.1.164.3.3.1.3.22.1.3INTEGERread-writeThis is a command to move to manual Redundancy flip mode for this redundancy couple. Default = off(2).
I32 sysSAlrAttrIndication1.3.6.1.4.1.164.3.3.1.3.23Integer32read-onlyThis object indicates the status of the Alarm Attributes for the whole device. It is a sum of 2**(Bit-1). A Bit will be '1', when any alarm in the device is Filtered/Masked/Inverted (respectively). The Bit assignment is: Bit 1: Filter (LSB) Bit 2: Mask Bit 3: Invert (MSB). Examples: - Alarms are filtered and masked but not inverted: value=3 - Alarm is Inverted (not filtered or masked): value=4 - Alarm is masked (not inverted or filtered): value=2
sysCurrentAlr1.3.6.1.4.1.164.3.3.1.4
sysSAlrTable1.3.6.1.4.1.164.3.3.1.4.1not-accessibleList of system level current existing alarms .
sysSAlrEntry1.3.6.1.4.1.164.3.3.1.4.1.1not-accessibleAn entry in table.
I32 sysSAlrIdx1.3.6.1.4.1.164.3.3.1.4.1.1.1Integer32read-onlyAn index number of the current system alarms.
I32 sysSAlrCode1.3.6.1.4.1.164.3.3.1.4.1.1.2Integer32read-onlyThis object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable.
INT sysSAlrState1.3.6.1.4.1.164.3.3.1.4.1.1.3INTEGERread-onlyThis object indicates the alarm Severity.
INT sysSAlarmMask1.3.6.1.4.1.164.3.3.1.4.1.1.4INTEGERread-onlyAlarm Mask is : on/off.
INT sysSAlarmInvert1.3.6.1.4.1.164.3.3.1.4.1.1.5INTEGERread-onlyAlarm Invert is : on/off.
INT sysSAlarmOnOff1.3.6.1.4.1.164.3.3.1.4.1.1.6INTEGERread-onlyAlarm state is : on/off.
I32 sysSAlarmCounter1.3.6.1.4.1.164.3.3.1.4.1.1.7Integer32read-onlyA counter - how many times the alarm occured (ON) since last clear operation or since last Reset.
INT sysSAlrClearCmd1.3.6.1.4.1.164.3.3.1.4.2INTEGERread-writeSetting this attribute to ON, will enforce a clear operation on the system level alarms . Upon completion, the value will automatically change to off(2).
INT sysSAlrClearAllCmd1.3.6.1.4.1.164.3.3.1.4.3INTEGERread-writeSetting this attribute to ON, will enforce a clear operation on all levels alarms . Upon completion, the value will automatically change to off(2).
INT sysSAlrMaskAll1.3.6.1.4.1.164.3.3.1.4.4INTEGERread-writeon(3) - will cause masking of all the system level alarms. These alarms will not be sent to NMS and will not be taken into account for Alarms Status. off(2) - will unmask all system level alarms except those masked via the sysSAlrMask.
OCT sysSAlrMask1.3.6.1.4.1.164.3.3.1.4.5OCTET STRINGread-writeThis object is a mask that indicates which system level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the system level will be 0. This object is applicable only when sysSAlrMaskAll=off (otherwise all system alarms are masked). Example: When Alarms having the codes 6 and 11 are masked, the value of this object will be 840 (hex).
INT sysSAlrDataUpdateCmd1.3.6.1.4.1.164.3.3.1.4.6INTEGERread-writeon(3) - will cause Update of the Alarms Severity, Attributes and Report tables. off(2) - Upon completion, the value will automatically change to off(2).
sysBufferAlr1.3.6.1.4.1.164.3.3.1.5
sysBufferAlrTable1.3.6.1.4.1.164.3.3.1.5.1not-accessibleList of current existing alarms (of all levels).
sysBufferAlrEntry1.3.6.1.4.1.164.3.3.1.5.1.1not-accessibleAn entry in table.
I32 sysBufferAlrIdx1.3.6.1.4.1.164.3.3.1.5.1.1.1Integer32read-onlyAn index number of the current alarms.
I32 sysBufferAlrCode1.3.6.1.4.1.164.3.3.1.5.1.1.2Integer32read-onlyThis object indicates a code related to a specific alarm description. The list of codes and thir related descriptions will be known by the NMS (for display purpose) and will appear in the unit's user manual.
INT sysBufferAlrState1.3.6.1.4.1.164.3.3.1.5.1.1.3INTEGERread-onlyThis object indicates the alarm type. minor/major/warning/critical - indicates appearance of the problem and the type. event - indicates occurence of an event. off - indicates disappearance of an alarm.
INT sysBufferAlrSlot1.3.6.1.4.1.164.3.3.1.5.1.1.4INTEGERread-onlyThe slot number this alarm refers to. When the alarm refers to a system function OR the DACS agent is a stand-alone unit, the value will be 'notApplicable(255)'. local/remote - for OP-4 device.
I32 sysBufferAlrPort1.3.6.1.4.1.164.3.3.1.5.1.1.5Integer32read-onlyThe port number this alarm refers to. If the port number is irrelevant to this alarm (if it is a system/card level alarm) the value will be 9999.
STR sysBufferAlrDate1.3.6.1.4.1.164.3.3.1.5.1.1.6DisplayStringread-onlyThe date when the alarm occured. The format will be according to sysSDateFormat.
STR sysBufferAlrTime1.3.6.1.4.1.164.3.3.1.5.1.1.7DisplayStringread-onlyThe time when the alarm occured.
TIK sysBufferAlrUpTime1.3.6.1.4.1.164.3.3.1.5.1.1.8TimeTicksread-onlyThe time when the alarm occured. This parameter holds the sysUpTime value when the alarm occured.
STR sysBufferAlrInfo1.3.6.1.4.1.164.3.3.1.5.1.1.9SnmpAdminStringread-onlyThis parameter includes information about the alarm (additional to the Description).
INT sysBufferAlrClearCmd1.3.6.1.4.1.164.3.3.1.5.2INTEGERread-writeSetting this attribute to ON, will enforce a clear operation on the Alarms Buffer. Upon completion, the value will automatically change to off(2).
sysConfig1.3.6.1.4.1.164.3.3.1.6
sysCClkSrcTable1.3.6.1.4.1.164.3.3.1.6.1not-accessibleAll the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. For devices with more than one configuration: The write operation into the Table Objects is valid only for the TmpCnfg entry.
sysCClkSrcEntry1.3.6.1.4.1.164.3.3.1.6.1.1not-accessibleAn entry in table.
I32 sysCClkCnfgIdx1.3.6.1.4.1.164.3.3.1.6.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg being accessed ; Idx of 255 relates to the TmpCnfg. It can be also a combination of the configuration number and the Card/Port/Other System index.
INT sysCClkSrcIdx1.3.6.1.4.1.164.3.3.1.6.1.1.2INTEGERread-onlyAn index in the table. There are only two entries in the table. master - refers Master clock parameters fallback - refers Fallback clock parameters
INT sysCClkSrcMode1.3.6.1.4.1.164.3.3.1.6.1.1.3INTEGERread-writeThis entry indicates the source the nodal timing is locked to. none - is an invalid option for Master clock. internal - is an invalid option for Fallback clock . station - is an invalid option for a stand-alone unit. lbt - loop-back timing ntr - Network Time Reference adaptive - clock locking is achieved by altering the clock according to the data load system - irrelevant when sysCClkCnfgIdx refers to System Clock. sSubSystem - SONET/SDH Sub System. recovered - clock recovery. notApplicable - for ML source of Kmux or ML Timing combinations when Master/Fallback clock are not applicable.
I32 sysCClkSrcPrt1.3.6.1.4.1.164.3.3.1.6.1.1.4Integer32read-writeThis entry is valid only when working in rxClk mode (for IPmux1000 this entry will be valid whe working in LBT mode). For ACE2002 in case of invalid entry the return value will be 0. For other products in case of invalid entry the return value will be 9999. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The SP ports will be numbered as follows: - SP port 1 : 1 - SP port 2 : 2 For external ports the convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For Kmux, the port will be according to : Slot*100+Ch. For ACE2002, LA140 and IPmux1000 (GMUX), the port will be ifIndex.
INT sysCClkStationFreq1.3.6.1.4.1.164.3.3.1.6.1.1.5INTEGERread-writeThis entry indicates the frequency of the station clock when the source is 'station'. The value will be applicable only when the sysCClkSrcMode is 'station'.
I32 sysCClkRevertiveTimeout1.3.6.1.4.1.164.3.3.1.6.1.1.6Integer32read-writeThe time in seconds in which the system will monitor the higher level clock source, before decision to revert to that clock. In case the time is zero, revertive mode will be disabled.
INT sysCClkStationIf1.3.6.1.4.1.164.3.3.1.6.1.1.7INTEGERread-writeThis entry indicates the electrical interface connected to the station clock, when the source is 'station'. The value will be applicable only when the sysCClkSrcMode is 'station'.
INT sysCClkStationCableMode1.3.6.1.4.1.164.3.3.1.6.1.1.8INTEGERread-writeThis parameter indicates whether both Station clocks get their clock from the same source (Y Cable)or each one get its clock independently. The value will be applicable only when the sysCClkSrcMode is 'station'.
INT sysCClkStationOutState1.3.6.1.4.1.164.3.3.1.6.1.1.9INTEGERread-writeThis parameter indicates whether station clock can send its clock to another device. The value will be applicable only when the sysCClkSrcMode is 'station'.
INT sysCClkSsmBased1.3.6.1.4.1.164.3.3.1.6.1.1.10INTEGERread-writeThis parameter indicates whether clock source will be selected based on receive clock quality, indicated in S1 byte inside SONET/SDH overhead, (encoded as SSM - Synchronization Status Messaging). It is relevant only for sysCClkSrcIdx=master. When the value is Yes, sysCClkSrcMode must be notApplicable.
INT sysCClkSSubsystemSlot1.3.6.1.4.1.164.3.3.1.6.1.1.11INTEGERread-writeThis entry indicates the Slot from which the S Subsytem Source will be taken. The value will be applicable only when the sysCClkSrcMode is 'sSubsystem'.
U32 sysCClkRecoveredID1.3.6.1.4.1.164.3.3.1.6.1.1.12Unsigned32read-writeThis entry indicates the Recovered Clock ID. The value will be applicable only when sysCClkSrcMode is 'recovered'.
sysCnfgTable1.3.6.1.4.1.164.3.3.1.6.2not-accessibleAll the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
sysCnfgEntry1.3.6.1.4.1.164.3.3.1.6.2.1not-accessibleAn entry in table.
I32 sysCnfgIdx1.3.6.1.4.1.164.3.3.1.6.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg. For Gmux2000 the range limitation (1..255) was discarded since the Idx is computed as: x 1000 + 255.
INT sysCMatrixMode1.3.6.1.4.1.164.3.3.1.6.2.1.2INTEGERread-writeIndicates the TS Matrix Mode: bidirectional - TS Assignment Matrix is symmetric. unidirectional - TS Assignment Matrix can be asymmetric. notApplicable - for agents that do not support this feature.
INT sysCIsdnFormat1.3.6.1.4.1.164.3.3.1.6.2.1.3INTEGERread-writeISDN format. This parameter controls the operation mode of the ISDN ports. te - ISDN timing is derived from the signal received from the equipment it is connected to. nt - timing of the transmit path is locked to the nodal timing source. notApplicable - for agents that do not support this feature.
INT sysCRoutingOnEth1.3.6.1.4.1.164.3.3.1.6.2.1.4INTEGERread-writeMng Routing Protocol on the online CL Ethernet port, or on device Ethernet port dedicated for mangement.
INT sysCAutoConfigEnable1.3.6.1.4.1.164.3.3.1.6.2.1.5INTEGERread-writeThis object enables user to enable/disable activating the Auto Configuration. When Auto Configuration is activated, the device learns its configuration Automatically from the Net it is connected to.
INT sysCIntTsAllocMode1.3.6.1.4.1.164.3.3.1.6.2.1.6INTEGERread-writeThis object enables user to select the mode of Internal TS Allocation. static - user has to select for each Dynamic card port, the Maximum TSs expected to be connected (including future growth). This number will be allocated to the ports, so that if number of connected TSs will grow within the limits of this Maximum TS limit, no disruption of data flow will occur for other ports. dynamic- TS allocation is done dynamically according to the connected TSs. No future reservations are done. This mode may cause data disruption on other ports/slots if user will want to change the number of connected TSs for a Dynamic card port. staticOneToOne - user has to select for each Dynamic card port, the Maximum TSs expected to be connected (including future growth). In addition, the TSs themselves cannot be higher than this defined Maximum (e.g if Maximum TSs=5 user cannot selects TSs higher than 5). This mode ensures that if number of TSs grow within the limits of this Maximum TS limit, no disruption of data flow will occur for other ports AND for the selected port itself. Default=static(2).
INT sysCBuPrimaryPort1.3.6.1.4.1.164.3.3.1.6.2.1.7INTEGERread-writeThis object enables the user to configure a Backup mechanism. If a backup mechanism exists, it is possible to configure the primary port. The traffic will flow via the primary port when the port functionality is OK. In Vmux-2100 device the backup mechanism is relevant for the Main Board only. The primary port can be the E1/T1/Serial port or the ETH port.
INT sysCEnableLanOverTdm1.3.6.1.4.1.164.3.3.1.6.2.1.8INTEGERread-writeThis object enables/disables transferring traffic from the LAN port to the TDM port. It is possible to enable only part of the traffic on the TDM port for security reasons or in order to minimize the bandwidth .
I32 sysCSs7FisuSuppression1.3.6.1.4.1.164.3.3.1.6.2.1.9Integer32read-writeSS7 Suppresion is used for SS7 Spoofing. The SS7 spoofing terminates the keep alive messages from the local VMUX without sending them over the network, thus improving the bandwidth utilization. FISU means Fill in Service Unit - Keep alive that is sent when no one is talking on the line. This object enables the configuration of the SS7 Keep Alive packet % that will be discarded. Legal Values: 0 - No Suppression, 10%, 20%, 30% .. 90% Example: For a value of 10, 1 keep alive packet will be discarded out of 10 keep alive packets that were supposed to be sent over the network.
INT sysCBuRecMode1.3.6.1.4.1.164.3.3.1.6.2.1.10INTEGERread-writeRecovery Mode. This object determines if after recovery of the Primary Link (used in Vmux) it will become on-line again or not: auto - automatic. In this case, the failed Link will become on-line again after recovery, automatically. manual - In this case, the failed Link will not become on-line again after recovery but user can manually flip to this Link.
sysCRdnTable1.3.6.1.4.1.164.3.3.1.6.3not-accessibleConfiguration of all Redundant I/O cards and ports. The write operation into the table objects is valid only for the TmpCnfg. A Slot/Port that have no Redundancy, will not exist in this table.
sysCRdnEntry1.3.6.1.4.1.164.3.3.1.6.3.1not-accessibleAn entry in table.
I32 sysCRdnCnfgIdx1.3.6.1.4.1.164.3.3.1.6.3.1.1Integer32read-onlyThis object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
INT sysCRdnPrimeSlot1.3.6.1.4.1.164.3.3.1.6.3.1.2INTEGERread-onlyThe slot number of the Primary card of Redundancy. The Primary card should be the card that user wishes to be the online card (usually the more important one). For some Redundancy modes the importance of the redundant cards/ports is the same.
I32 sysCRdnPrimePort1.3.6.1.4.1.164.3.3.1.6.3.1.3Integer32read-onlyThe port number. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 For IP Bundles, the value will be the Bundle ifIndex. For an IP Bundle that is in an External Device (not in this MP), the value will be: 70,000 + ifIndex of Secondary Bundle. For other products - refer to product specification. 100=notApplicable (when Redundancy is at card level).
INT sysCRdnSecSlot1.3.6.1.4.1.164.3.3.1.6.3.1.4INTEGERread-createThe slot number of the Secondary card of Redundancy matching the Primary slot.
I32 sysCRdnSecPort1.3.6.1.4.1.164.3.3.1.6.3.1.5Integer32read-createThe port number. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 For IP Bundles, the value will be the Bundle ifIndex. For an IP Bundle that is in an External Device (not in this MP), the value will be: 0. For other products - refer to product specification. 100=notApplicable (when Redundancy is at card level).
INT sysCRdnMode1.3.6.1.4.1.164.3.3.1.6.3.1.6INTEGERread-createRedundancy Mode. DXC supports: yCable(3), singleSlotProtection(6) and dualCableParallelTx(4) MP supports: yCable(3), dualCableParallelTx(4), onePlusOne(7) and oneToOne(8). (dualCableAIS and backup were planned for MP but were not implemented). backup - will be used when a port is backup of more than one port. IPmux: onePlusOne(7) and oneToOne(8) are used for Bundle redundancy.
INT sysCRdnRecMode1.3.6.1.4.1.164.3.3.1.6.3.1.7INTEGERread-createRecovery Mode. This object determines if after recovery of the failed Primary card/port it will become on-line again or not: auto - automatic . In this case, the failed card/port will become on-line again after recovery, automatically. manual - In this case, the failed card/port will not become on-line again after recovery. But, user can manually flip to this card/port. nonRevertive - same as manual, but here user CANNOT manually flip to this card/port. It will become on-line again, only if the Secondary/Backup card/port will fail.
I32 sysCRdnRecTime1.3.6.1.4.1.164.3.3.1.6.3.1.8Integer32read-createRedundancy Recovery Time (sec). After switching to the current online card, the next switch can be performed only after a minimum time, indicated by this object. Valid Values: 0..300, 65535. 65535=NA. This object is applicable only when sysCRdnRecMode=auto.
INT sysCRdnHwSwFlip1.3.6.1.4.1.164.3.3.1.6.3.1.9INTEGERread-createHW or SW decision for Redundancy Flip. This object is applicable only for sysCRdnMode=singleSlotProtection. HW - decision is by I/O card SW - decision is by CL SW.
ROW sysCRdnRowStatus1.3.6.1.4.1.164.3.3.1.6.3.1.10RowStatusread-createThis parameter allows NMS to create/delete entries of this table. The possible supported RowStatus values are active (1) and destroy (6). For Vmux-2100 the supported values are: active (1), createAndGo (4) and destroy (6).
INT sysCRdnOnline1.3.6.1.4.1.164.3.3.1.6.3.1.11INTEGERread-onlyStatus - who is the Online (current) Redundancy Slot/Port. This object shows only the Online Slot/Port regarding the Redundancy. mdlSActivity or prtGenActiveStatus of the same Slot/Port may be Offline.
INT sysCRdnSwitchingMode1.3.6.1.4.1.164.3.3.1.6.3.1.12INTEGERread-createThis object defines which Self Healing Ring (SHR) SDH ring is used: Uni Directional or BiDirectional. The type of the ring is defined according to the direction of traffic flow under normal working conditions. In Bi Directional ring, the duplex traffic is on the same path and transverses the same set of nodes for both directions of transmission. In Uni Directional ring, the duplex traffic travels over opposite path (per direction) and all the node of the ring are involved. For Uni Directional SHR Protection Switching (Single Ended Switching) is controlled by one node of the SDH ring, and does not require a protocol. For Bi Directional SHR Protection Switching (Dual Ended switching) is controlled by some nodes of the ring and requires a protocol
I32 sysCRdnFlipUponEvent1.3.6.1.4.1.164.3.3.1.6.3.1.13Integer32read-createThis object allows user to define if Flip to the other port will be performed (or not), for certain possible events. Each event is represented by a bit. The value of the object is a sum of 2**n, according to the bits having '1' value. '1' - means that Flip should occur due to this event. Bit 0 (LSB) = SD (Signal Degraded). For IPmux: Bit 0 (LSB) = TDM Line LOS/LOF. Bit 1 = Sequence Number. Bit 2 = Jitter Buffer errors.
I32 sysCRdnLosOrLofTime1.3.6.1.4.1.164.3.3.1.6.3.1.14Integer32read-createThis parameter determines how much time to wait before switching, after LOF or LOS are detected on the TDM Line. For Ipmux time is counted in msec.
I32 sysCRdnEventsTimeWindow1.3.6.1.4.1.164.3.3.1.6.3.1.15Integer32read-createThis parameter determines the time window in which to count events to trigger protection switching. For Ipmux time is counted in seconds.
I32 sysCRdnSequenceNumberThreshold1.3.6.1.4.1.164.3.3.1.6.3.1.16Integer32read-createThis parameter determines the number of Sequence Number errors that should occur in the time window in order to cause switching.
I32 sysCRdnBufferErrorsThreshold1.3.6.1.4.1.164.3.3.1.6.3.1.17Integer32read-createThis parameter determines the number of Buffer undeflow/ overflow events occured in the time window that cause switching.
I32 sysCRdnBuffUnderrunTime1.3.6.1.4.1.164.3.3.1.6.3.1.18Integer32read-createThis parameter determines how much time to wait before switching, after jitter buffer underrun. Switching occurs if no frame arrives within that time. For Ipmux time is counted in msec.
INT sysCRdnPrimePriority1.3.6.1.4.1.164.3.3.1.6.3.1.19INTEGERread-createThe Primary port priority. In ETX2xx/2xxA: When selecting sysCRdnMode = manual (10), this parameter determines the forced active port: low - means that the secondary port is selected to be active high - means that the primary port is selected to be active.
INT sysCRdnSecPriority1.3.6.1.4.1.164.3.3.1.6.3.1.20INTEGERread-createThe Secondary port priority.
U32 sysCRdnWTR1.3.6.1.4.1.164.3.3.1.6.3.1.21Unsigned32read-createRedundancy Wait to Restore (sec). Valid Values: 0..999, 65535. 65535=NA. When the value <> 65535, the value of sysCRdnRecTime must be 65535.
STR sysCRdnName1.3.6.1.4.1.164.3.3.1.6.3.1.22SnmpAdminStringread-createA textual name for the redundancy group.
U32 sysCRdnTxDownDurationUponFlip1.3.6.1.4.1.164.3.3.1.6.3.1.23Unsigned32read-createThis object defines the duration (in seconds) the active port transmission is shut down after flip occurs. The transmission is shut down and then opened again (after the duration defined by this object), in order to cause the other side to flip to the new active port. 0 = no shut-down. This object is applicable only when sysCRdnMode = oneToOne(8) and mainly when each of the links of our device is connected to a different device.
sysDbase1.3.6.1.4.1.164.3.3.1.7
INT sysDbaseSanityCheckCmd1.3.6.1.4.1.164.3.3.1.7.1INTEGERread-writeSetting this attribute to on(3) will initiate the process of Sanity check on the TmpCnfg. Upon completion, the value will automatically change to off(2).
I32 sysDbaseDownloadCnfgIdxCmd1.3.6.1.4.1.164.3.3.1.7.2Integer32read-writeThis attribute specifies the Id of the target RealCnfg to which the TmpCnfg should be transferred. Upon set command, the DACS agent will initiate the Sanity-Check process. If successful, the actual transfer will be performed. If there will be errors, the user will have to perform the command again after errors correction. The operation is valid only on configuration numbers that do not exceed sysSMaxNoOfCnfg.
I32 sysDbaseUploadCnfgIdxCmd1.3.6.1.4.1.164.3.3.1.7.3Integer32read-writeThis attribute specifies the Id of the source Cnfg to be loaded into the TmpCnfg. Upon set operation the actual transfer will be initiated. The operation is valid only on configuration numbers that do not exceed sysSMaxNoOfCnfg.
sysDbaseFlipTable1.3.6.1.4.1.164.3.3.1.7.4not-accessibleDbase Flip time and activation for every configuration.
sysDbaseFlipEntry1.3.6.1.4.1.164.3.3.1.7.4.1not-accessibleAn entry in table.
I32 sysDbaseFlipIdx1.3.6.1.4.1.164.3.3.1.7.4.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg being the target Configuration.
STR sysDbaseFlipTime1.3.6.1.4.1.164.3.3.1.7.4.1.2DisplayStringread-writeThis attribute indicates the time (HH:MM) when this data base will start being used by the Tmp config.
INT sysDbaseFlipActivation1.3.6.1.4.1.164.3.3.1.7.4.1.3INTEGERread-writeThis attribute indicates if the Dbase flip will be activated at the time specified for this configuration (enable) or not (disable). No more than one flip should be enabled for the same time.
mdlDacsMux1.3.6.1.4.1.164.3.3.2
mdlGen1.3.6.1.4.1.164.3.3.2.1
mdlSTable1.3.6.1.4.1.164.3.3.2.1.1not-accessibleA table.
mdlSEntry1.3.6.1.4.1.164.3.3.2.1.1.1not-accessibleAn entry in table.
INT mdlSSltIdx1.3.6.1.4.1.164.3.3.2.1.1.1.1INTEGERread-onlyA unique number to identify a slot position in the DACS. The Kilomux should use enumerated values starting with kmx. For IPmux100 use values 1-13, 20.
INT mdlSCardType1.3.6.1.4.1.164.3.3.2.1.1.1.2INTEGERread-onlyThis attribute indicates the type of the card installed in the specific slot position. Only PS's are possible in the PS slots. Only CL's are possible in the CL slots. Only IO modules are possible in the IO slots. Kmux card type start with the letter k. LA card type start with the letters la.
STR mdlSHwVer1.3.6.1.4.1.164.3.3.2.1.1.1.3DisplayStringread-onlyThis attribute indicates the Hardware version of the card installed in the specific slot position.
STR mdlSSwVer1.3.6.1.4.1.164.3.3.2.1.1.1.4DisplayStringread-onlyThis attribute indicates the Software version of the card installed in the specific slot position.
INT mdlSAlarmStatus1.3.6.1.4.1.164.3.3.2.1.1.1.5INTEGERread-onlyIndicates the current alarm state only for card level. This object will be set to: - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
INT mdlSAlarmStatusAll1.3.6.1.4.1.164.3.3.2.1.1.1.6INTEGERread-onlyIndicates the current card alarm state including the lower level: card, port. This object will be set to: - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
INT mdlSTestStatus1.3.6.1.4.1.164.3.3.2.1.1.1.7INTEGERread-onlyThis attribute will be on(3) when there is at least one test running on a port of the module; otherwise the value will be off(2).
INT mdlSHwStatus1.3.6.1.4.1.164.3.3.2.1.1.1.8INTEGERread-onlyThis attribute will be fail(2) when a HW FAIL exists on this module (discovered by periodic self test); otherwise the value will be ok(3).
INT mdlSActivity1.3.6.1.4.1.164.3.3.2.1.1.1.9INTEGERread-onlynotApplicable - when the slot is empty (no module) offline(1) - when the module is not active (redundant) online (2) - when the module is active .
INT mdlSAlrClearCmd1.3.6.1.4.1.164.3.3.2.1.1.1.10INTEGERread-writeSetting this attribute to ON, will enforce a clear operation on the card level alarms . Upon completion, the value will automatically change to off(2).
INT mdlSAlrClearAllCmd1.3.6.1.4.1.164.3.3.2.1.1.1.11INTEGERread-writeSetting this attribute to ON, will enforce a clear operation on card and port level alarms . Upon completion, the value will automatically change to off(2).
INT mdlSAlrMaskAll1.3.6.1.4.1.164.3.3.2.1.1.1.12INTEGERread-writeon(3) - will cause masking of all the card level alarms. These alarms will not be sent to NMS and will not be taken into account for Alarms Status. off(2) - will unmask all card level alarms except those masked via the mdlAlrMaskTable.
I32 mdlSCmd1.3.6.1.4.1.164.3.3.2.1.1.1.13Integer32read-writeGeneral object for any special command at card level. 0=NotApplicable, for cards that don't support this object. For KML.10(ISDN) card of KM-2100, the object will indicate Manual Call Command in Switch mode. It is applicable only when for KML.10, prtIsdnSwitchMode=manual. KML.10 valid values: '1' = noOp, will be used by agents that do not support this feature or object (old KM agents) '2' = off, Set call command mode to disconnect state. Disconnects the call. '3' = on, Set call command mode to connect state. Connects the call. For DXC IO cards, the object will be used for IO Card Reset HW command: '2' = off, this will be always the Get value for these cards. '3' = on, this is the Set command used to Reset the IO card. Upon completing the operation, the value will automatically change to off(2), by Agent. For Slots that are NOT IO Slots and for empty IO Slots, the Get value will be always '0' (NotApplicable).
INT mdlSReset1.3.6.1.4.1.164.3.3.2.1.1.1.14INTEGERread-writeReset action to be performed on the module.
INT mdlSRebuildFrame1.3.6.1.4.1.164.3.3.2.1.1.1.15INTEGERread-writeApplicable only for KiloMux Main Link cards only. '2' = off, this will be always the Get value. '3' = on, this is the Set command used to Rebuild the Frame. Upon completing the operation, the value will automatically change to off(2), by Agent.
STR mdlSBackupSwVer1.3.6.1.4.1.164.3.3.2.1.1.1.16DisplayStringread-onlyThis attribute indicates the Backup Software version of the card installed in the specific slot position.
STR mdlSSecondaryBackupSwVer1.3.6.1.4.1.164.3.3.2.1.1.1.17DisplayStringread-onlyThis attribute indicates the Secondary Backup Software version of the card installed in the specific slot position.
STR mdlSPiggybackVer1.3.6.1.4.1.164.3.3.2.1.1.1.18SnmpAdminStringread-onlyThis attribute indicates the Piggyback version of the card installed in the specific slot position.
mdlCTable1.3.6.1.4.1.164.3.3.2.1.2not-accessibleA table.
mdlCEntry1.3.6.1.4.1.164.3.3.2.1.2.1not-accessibleAn entry in table.
I32 mdlCConfigIdx1.3.6.1.4.1.164.3.3.2.1.2.1.1Integer32read-onlyThis object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch).
INT mdlCSlotIdx1.3.6.1.4.1.164.3.3.2.1.2.1.2INTEGERread-onlyThis object indicates a unique number of the slot position in which the module is inserted. The Kilomux should use enumerated values starting with kmx.
INT mdlCProgCardType1.3.6.1.4.1.164.3.3.2.1.2.1.3INTEGERread-writeThis object indicates the card type assigned to the specific slot in the common configuration. This object is identical for all the configurations (1..255). Only the TmpCnf(255) might have a different value. The write operation is valid only for the TmpCnfg entry.
I32 mdlCNoOfExtPrt1.3.6.1.4.1.164.3.3.2.1.2.1.4Integer32read-onlyNumber of external ports in the programmed module of the specific slot position
I32 mdlCNoOfIntPrt1.3.6.1.4.1.164.3.3.2.1.2.1.5Integer32read-onlyNumber of internal ports in the programmed module of the specific slot position.
I32 mdlCParam1.3.6.1.4.1.164.3.3.2.1.2.1.6Integer32read-writeGeneral configuration object at card level (per configuration). NotApplicable=0, for cards that don't support this object. For D8U and D16U cards of DXC, the object will indicate the port on which BERT will be performed. The port can be one of the external ports, any of its associated B1, B2, D ports or no port of the card (None=0). For port indexes see DXC R6 spec. For Gmux-2000, this parameter used for determining the Gigabit ETH exit port
mdlAlr1.3.6.1.4.1.164.3.3.2.1.3
mdlAlrTable1.3.6.1.4.1.164.3.3.2.1.3.1not-accessibleThe list of card alarms.
mdlAlrEntry1.3.6.1.4.1.164.3.3.2.1.3.1.1not-accessibleAn entry in table.
I32 mdlAlrIdx1.3.6.1.4.1.164.3.3.2.1.3.1.1.1Integer32read-onlyA unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive
INT mdlAlrSltIdx1.3.6.1.4.1.164.3.3.2.1.3.1.1.2INTEGERread-onlyThis attribute indicates the desired slot position. The Kilomux should use enumerated values starting with kmx.
I32 mdlAlrCode1.3.6.1.4.1.164.3.3.2.1.3.1.1.3Integer32read-onlyThis object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable.
INT mdlAlrState1.3.6.1.4.1.164.3.3.2.1.3.1.1.4INTEGERread-onlyThis object indicates the card alarm severity.
INT mdlAlarmMask1.3.6.1.4.1.164.3.3.2.1.3.1.1.5INTEGERread-onlyAlarm Mask is : on/off.
INT mdlAlarmInvert1.3.6.1.4.1.164.3.3.2.1.3.1.1.6INTEGERread-onlyAlarm Invert is : on/off.
INT mdlAlarmOnOff1.3.6.1.4.1.164.3.3.2.1.3.1.1.7INTEGERread-onlyAlarm state is : on/off.
I32 mdlAlarmCounter1.3.6.1.4.1.164.3.3.2.1.3.1.1.8Integer32read-onlyA counter - how many times the alarm occured (ON) since last clear operation or since last Reset.
mdlAlrMaskTable1.3.6.1.4.1.164.3.3.2.1.3.2not-accessibleThe list of card masked alarms.
mdlAlrMaskEntry1.3.6.1.4.1.164.3.3.2.1.3.2.1not-accessibleAn entry in table.
INT mdlAlrMaskSltIdx1.3.6.1.4.1.164.3.3.2.1.3.2.1.1INTEGERread-onlyThis attribute indicates the desired slot position. The Kilomux should use enumerated values starting with kmx.
OCT mdlAlrMask1.3.6.1.4.1.164.3.3.2.1.3.2.1.2OCTET STRINGread-writeThis object is a mask that indicates which card level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the card level will be 0. This object is applicable only when mdlSAlrMaskAll=off (otherwise all card alarms are masked). Example: When Alarm having the code 8 is masked, the value of this object will be 100 (hex).
mdlCl1.3.6.1.4.1.164.3.3.2.2
mdlClTable1.3.6.1.4.1.164.3.3.2.2.1not-accessibleA table.
mdlClEntry1.3.6.1.4.1.164.3.3.2.2.1.1not-accessibleAn entry in table.
INT mdlClIdx1.3.6.1.4.1.164.3.3.2.2.1.1.1INTEGERread-onlyThis object indicates the Cl slot referred.
I32 mdlClSwchStatus1.3.6.1.4.1.164.3.3.2.2.1.1.2Integer32read-onlyThis object indicates the status of the switches on the referred DCL card. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits. There are 4 switches: bit 0 SP-PAR (LSB) '1' - Default parameters bit 1 PSWRD '1' - Password=default '0' - Password=user selected bit 2 DB-INIT '1' - DB initiated with default '0' - DB initiated with NVRAM contents bit 3 PC-SP (MSB) '1' - Management by terminal only '0' - Management by NMS Example: If SP-PAR and PSWRD bits are set ('1'), the value will be 3 (2**1 + 2**0). When the status of the switches is unknown, the value of this object will be 255.
STR mdlClLastFlipDate1.3.6.1.4.1.164.3.3.2.2.1.1.3DisplayStringread-onlyDate when last flip occured. The format would be as specified by the sysSDateFormat.
STR mdlClLastFlipTime1.3.6.1.4.1.164.3.3.2.2.1.1.4DisplayStringread-onlyTime when last flip occured.
STR mdlClLastFlipCause1.3.6.1.4.1.164.3.3.2.2.1.1.5DisplayStringread-onlyThe cause of last flip.
mdlPs1.3.6.1.4.1.164.3.3.2.3
mdlPsTable1.3.6.1.4.1.164.3.3.2.3.1not-accessibleA table.
mdlPsEntry1.3.6.1.4.1.164.3.3.2.3.1.1not-accessibleAn entry in table.
INT mdlPsIdx1.3.6.1.4.1.164.3.3.2.3.1.1.1INTEGERread-onlyThis object indicates the PS card referred.
INT mdlPsStatus1.3.6.1.4.1.164.3.3.2.3.1.1.2INTEGERread-onlyThis object indicates the status of the PS card.
INT mdlPsTestResult1.3.6.1.4.1.164.3.3.2.3.1.1.3INTEGERread-onlyThis object indicates the result of the PS card test. ok (1) - the test passed successfully. f12V (2) - 12V FAIL was detected f5V (3) - 5V FAIL was detected.
prtDacsMux1.3.6.1.4.1.164.3.3.3
prtGen1.3.6.1.4.1.164.3.3.3.1
prtGenParamTable1.3.6.1.4.1.164.3.3.3.1.1not-accessibleA table.
prtGenEntry1.3.6.1.4.1.164.3.3.3.1.1.1not-accessibleAn entry in table.
I32 prtGenPrtIdx1.3.6.1.4.1.164.3.3.3.1.1.1.1Integer32read-onlyThis attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
INT prtGenSlt1.3.6.1.4.1.164.3.3.3.1.1.1.2INTEGERread-onlyThis attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used. The Kilomux should use the enumerated starting with kmx.
INT prtGenExtInt1.3.6.1.4.1.164.3.3.3.1.1.1.3INTEGERread-onlyThis attribute describes the type of the designated port. Exteral port is a port with a physical connector. Internal port might be of two types, one is a composite port which collects data of a few external ports into a common bandwidth (usually routed trough DS1 link); the other type is internal ports which get only part of external port data (usually a few DS0's). In the Kilomux-2100, the internal(3) value is used for composite channels or sub-channels of an ISDN Ch.
I32 prtGenIfIndex1.3.6.1.4.1.164.3.3.3.1.1.1.4Integer32read-onlyThis attribute indicates the unique interface number assigned to the port. The specific interface of this attribute is the same as the interface identified by the value of ifindex in MIB-II.If there is no interface for the specific prtIdx, the value will be '7fffffff'h.
INT prtGenActiveStatus1.3.6.1.4.1.164.3.3.3.1.1.1.5INTEGERread-onlyThis attribute describes the activity status of the port. unknown(1) indicates that the information is not supported. notUsed(2) indicates that the port is not connected according to the active config. offLine(3) indicates that the port is down (not working) due to any problem. onLine (4) indicates that the port is up (working) offLineRedundancy(5) indicates that the port is down because it is a redundant port. onLineRedundancy (6) indicates that this is a redundant port which is up and works as the active link.
INT prtGenAlrStatus1.3.6.1.4.1.164.3.3.3.1.1.1.6INTEGERread-onlyIndicates the alarm state at port (ch) agent level. This object will be: - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
INT prtGenTestStatus1.3.6.1.4.1.164.3.3.3.1.1.1.7INTEGERread-onlyThis attribute will be on(3) when there is at least one test in progress (running) on the port; otherwise the value will be off(2).
I32 prtGenTestMask1.3.6.1.4.1.164.3.3.3.1.1.1.8Integer32read-onlyThis is a mask which indicates which tests from the 'prtGenTestCmd' list are allowed for the selected port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
I32 prtGenTestCmd1.3.6.1.4.1.164.3.3.3.1.1.1.9Integer32read-writeSetting this object to a value as detailed furter on (except 0) will initiate a test on the specific port, if the operation is allowed (according to TestMask). If the operation is not allowed, the mux will ignore the operation. The test/s requested will be set according to the respective bit: TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 e.g : If the requested value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the requested tests are : local-loop remote-loop Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port; it will NOT stop the tests initiated by the system.
I32 prtGenTestRunning1.3.6.1.4.1.164.3.3.3.1.1.1.10Integer32read-onlyThis object indicates which tests are running currently on the selected port (initiated by user and/or by the system). If a specific test is currently running on the port, its respective bit will be SET: TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 llb 5 txInband 6 rxInband 7 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 DDS DSU loop 11 DDS CSU loop 12 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 Local DTE loop (HSSI)17 Local Line loop (HSSI)18 Remote Line loop (HSSI)19 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Network Line Loopback 24 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the running tests are : local-loop remote-loop llb (Bit 5) - can be initiated by system only!
INT prtGenType1.3.6.1.4.1.164.3.3.3.1.1.1.11INTEGERread-onlyThis object describes the type of the selected port. idsl - applicable for external ports of HS-U cards (of DXC) when interface is LT-1.
STR prtGenInterfaceType1.3.6.1.4.1.164.3.3.3.1.1.1.12DisplayStringread-onlyThis attribute indicates a unique HW interface type of the selected port. Examples: - for T1 cards: DSU, CSU - for E1 cards: DSU, LTU - for HS cards: v35, rs422, x21 etc...
INT prtGenAlrClearCmd1.3.6.1.4.1.164.3.3.3.1.1.1.13INTEGERread-writeSetting this attribute to ON, will enforce a clear operation on the port level alarms . Upon completion, the value will automatically change to off(2). noOp - will be used by agents that do not support this feature or object.
INT prtGenAlrMaskAll1.3.6.1.4.1.164.3.3.3.1.1.1.14INTEGERread-writeon(3) - will mask all the alarms of the selected port off(2)- will unmask all alarms of the selected port except the ones selected by the prtAlrMaskTable. noOp - will be used by agents that do not support this feature or object.
OCT prtGenParamStatus1.3.6.1.4.1.164.3.3.3.1.1.1.15OCTET STRINGread-onlyThis object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For HS cards (Dxc cards) - 1 octet: Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 0 and 1 indicates RTS control signal state: Bit 1: '1'=active ; '0'=notActive Bit 0 (LSB): '1'=unknown ; '0'=NA - For HS-U/1 external port (MP card, used in FCD-M) - 1 Octet: Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For VC-6, VC-12, VC-12/6 external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - --- CTS DSR DCD RJ TM DTR RTS Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) '---' will always have the value 00 Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=Unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For KM2100, KVF.5 cards - indicates the status of A and B signaling for each internal channel. 1 Octet: Bit - 7 6 5 4 3 2 1 0 |_____| |_| |_| spare B A Bit 0 (LSB) and Bit 1 : A status Bit 2 and Bit 3 : B status 00 - Off 01 - On 11 - Unknown - For FCD-W, NETWORK and USER ports - 1 Octet Status of Control Signals: '1'=On ; '0'=Off or when not applicable Bit - 7 6 5 4 3 2 1 0 Bit 7 (MSB) - Signal Loss (applicable only for G.703 interface) Bit 6 - CONTROL (applicable only for X.21 interface) Bit 5 - INDICATION (applicable only for X.21 interface) Bit 4 - DSR (applicable only for V.35 interface) Bit 3 - RTS (applicable only for V.35 interface) Bit 2 - CTS (applicable only for V.35 interface) Bit 1 - DTR (applicable only for V.35 interface) Bit 0 - DCD (applicable only for V.35 interface) - For DXC R6 , D8U, D16U External ports - 1 Octet Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For DXC DE1-HDSL, DT1-HDSL, D16GSDSL, D8SL External ports - 2 Octets MSB octet: far-end modem channel interface LSB octet: Sub Link existence (Y/N), far-end modem type, synchronization with far-end modem MSB octet: 0000 0000 = no interface 0000 0001 = db15 (X21) 0000 0010 = IR-IP 0000 0011 = IR-ETH-Q 0000 0100 = V35 0000 0101 = ETH-RJ45 0000 0110 = G703 0000 0111 = db25 (RS530) 0000 1000 = ETH-BNC 0000 1001 = E1(Balanced) 0000 1010 = E1(Unbalanced) 0000 1011 = IR-ETH-QN Rest of the combinations: reserved LSB octet: Bit 7 6 5 4 3 2 1 0 LSB | |___________| |__| SL modem sync or Box material SL: modem: 00000 = other sync: 00 = not sync 0=not exist 00001 = unknown 01 = sync 1=exists 00010 = ASMi-31/2 10 = reserved 00011 = HCD-E1 11 = reserved Box material 00100 = HTU-E1 (for D8SL card): 00101 = HTU-2 0=metal 00110 = ASMi-52 SA/2W/Slave 1=plastic 00111 = ASMi-52 SA/2W/Master 01000 = ASMi-52/CQ card of LRS-24 01001 = ASMi-52/CD card of LRS-24 01010 = D16GSDSL card of DXC-3000 01011 = LRS-52 01100 = FCD 01110 = D8GSDSL card of DXC-3000 01111 = ASMi-52A Rest = reserved
INT prtGenRdnStatus1.3.6.1.4.1.164.3.3.3.1.1.1.16INTEGERread-onlyThis object indicates if this port is part of a redundant pair and in this case, if it is On or Off. none(1) - No redundancy or Not Applicable off (2) - the port is part of a redundant pair and it is Off from Redundancy point of view (not the port used). on (3) - the port is part of a redundant pair and it is On from Redundancy point of view (it is the port used).
OCT prtGenTestMaskXP1.3.6.1.4.1.164.3.3.3.1.1.1.17OCTET STRINGread-onlyThis is an Expanded test mask of the prtGenTestMask object. The prtGenTestMask object reached its maximum, being an Integer with 31 bits. This object indicates which tests from the 'prtGenTestCmdXP' list are allowed for the selected port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- localLoop 1 =LSB remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 Downstream-AIS 32 Upstream-AIS 33 Send-RDI 34 Test Per TS 35 e.g : If the return value is 00000003 hex -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
OCT prtGenTestCmdXP1.3.6.1.4.1.164.3.3.3.1.1.1.18OCTET STRINGread-writeThis is an Expanded test command of the prtGenTestCmd object. The prtGenTestCmd object reached its maximum, being an Integer with 31 bits. Setting this object to a value as detailed furter on (except 0) will initiate a test on the specific port, if the operation is allowed (according to TestMaskXP). If the operation is not allowed, the mux will ignore the operation. The test/s requested will be set according to the respective bit: TEST BIT ----------- --- localLoop 1 =LSB remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 Downstream-AIS 32 Upstream-AIS 33 Send-RDI 34 Test Per TS 35 e.g : If the requested value is 00000003 hex -> Bits 1 & 2 are set -> the requested tests are : local-loop remote-loop Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port; it will NOT stop the tests initiated by the system.
OCT prtGenTestRunningXP1.3.6.1.4.1.164.3.3.3.1.1.1.19OCTET STRINGread-onlyThis is an Expanded object of the prtGenTestRunning object. The prtGenTestRunning object reached its maximum, being an Integer with 31 bits. This object indicates which tests are running currently on the selected port (initiated by user and/or by the system). If a specific test is currently running on the port, its respective bit will be SET: TEST BIT ----------- --- localLoop 1 =LSB remoteLoop 2 bert 3 plb 4 llb 5 txInband 6 rxInband 7 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 DDS DSU loop 11 DDS CSU loop 12 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 Local DTE loop (HSSI)17 Local Line loop (HSSI)18 Remote Line loop (HSSI)19 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Network Line Loopback 24 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 Downstream-AIS 32 Upstream-AIS 33 Send-RDI 34 Test Per TS 35 e.g : If the return value is 00000003 hex -> Bits 1 & 2 are set -> the running tests are : local-loop remote-loop llb (Bit 5) - can be initiated by system only!
prtGenTestDurationTable1.3.6.1.4.1.164.3.3.3.1.2not-accessibleA table.
prtGenTestDurationEntry1.3.6.1.4.1.164.3.3.3.1.2.1not-accessibleAn entry in table.
I32 prtGenTestPrtIdx1.3.6.1.4.1.164.3.3.3.1.2.1.1Integer32read-onlyThis attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
INT prtGenTestIdx1.3.6.1.4.1.164.3.3.3.1.2.1.2INTEGERread-onlyThis attribute indicates the test, the duration refers.
I32 prtGenTestDuration1.3.6.1.4.1.164.3.3.3.1.2.1.3Integer32read-writeThis attribute indicates the maximum duration of executing a test on the specific port. This entry applies to the specified test . The resolution will be a minute, and the maximum duration is limited to 30 minutes . A zero value specifies no time limitation. When the test isn't active the agent initiates this object to 2 min. when the duration is needed and to 0 if it's not required.
prtGenTsTable1.3.6.1.4.1.164.3.3.3.1.3not-accessibleThe write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch),exept some products which enable direct writing to the ActiveCnfg. This is written in the respective product's spec.
prtGenTsEntry1.3.6.1.4.1.164.3.3.3.1.3.1not-accessibleAn entry in table.
I32 prtGenTsCnfgIdx1.3.6.1.4.1.164.3.3.3.1.3.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
I32 prtGenTsPrtIdx1.3.6.1.4.1.164.3.3.3.1.3.1.2Integer32read-onlyThis attribute indicates a unique port number. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
I32 prtGenTsIdx1.3.6.1.4.1.164.3.3.3.1.3.1.3Integer32read-onlyThis attribute indicates a unique time slot position. The valid time slots are 1..25 for T1 Card (25=Fbit) 0..31 for E1 or HS Card . In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling.
INT prtGenTsType1.3.6.1.4.1.164.3.3.3.1.3.1.4INTEGERread-writeThe type of Timeslot. If the source or destination port is an HS port,'TS Type' must be 'data'. nc - means that this TimeSlot is not connected. voice, data, vcMP - also mean that this TS is connected. mng - means that this TS is dedicated to Management (not connected to another port.
I32 prtGenTsIConPrt1.3.6.1.4.1.164.3.3.3.1.3.1.5Integer32read-writeThis attribute indicates the internally (In Mux) connected port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside ports will be for example, the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . * noConnection - will be indicated as 10 for DXC and FCD-E1/T1. - will be indicated as 100 for FCD-E1/I and SMODs. * Split TS (same TS is Split to several ports) - 11. * notApplicable- will be indicated as 100 for LRS IMODs. All HS port's timeslots must have the same destination port.
I32 prtGenTsIConTs1.3.6.1.4.1.164.3.3.3.1.3.1.6Integer32read-writeThis attribute indicates a unique time slot position. The valid time slots are 1..25 for T1 Card (25=Fbit) 0..31 for E1 (or HS) Card. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling. * For DXC: All HS port's timeslots must start with Timeslot no.1
prtAlr1.3.6.1.4.1.164.3.3.3.1.4
prtSAlarmTable1.3.6.1.4.1.164.3.3.3.1.4.1not-accessibleA table.
prtSAlarmEntry1.3.6.1.4.1.164.3.3.3.1.4.1.1not-accessibleAn entry in table.
I32 prtSAlarmIdx1.3.6.1.4.1.164.3.3.3.1.4.1.1.1Integer32read-onlyA unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive.
I32 prtSAlarmPrtIdx1.3.6.1.4.1.164.3.3.3.1.4.1.1.2Integer32read-onlyThis attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
I32 prtSAlarmCode1.3.6.1.4.1.164.3.3.3.1.4.1.1.3Integer32read-onlyThis object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable.
INT prtSAlarmState1.3.6.1.4.1.164.3.3.3.1.4.1.1.4INTEGERread-onlyThis object indicates the port alarm severity.
INT prtSAlarmMask1.3.6.1.4.1.164.3.3.3.1.4.1.1.5INTEGERread-onlyAlarm Mask is : on/off.
INT prtSAlarmInvert1.3.6.1.4.1.164.3.3.3.1.4.1.1.6INTEGERread-onlyAlarm Invert is : on/off.
INT prtSAlarmOnOff1.3.6.1.4.1.164.3.3.3.1.4.1.1.7INTEGERread-onlyAlarm state is : on/off.
I32 prtSAlarmCounter1.3.6.1.4.1.164.3.3.3.1.4.1.1.8Integer32read-onlyA counter - how many times the alarm occured (ON) since last clear operation or since last Reset.
prtAlrMaskTable1.3.6.1.4.1.164.3.3.3.1.4.2not-accessibleA table.
prtAlrMaskEntry1.3.6.1.4.1.164.3.3.3.1.4.2.1not-accessibleAn entry in table.
I32 prtAlrMaskPrtIdx1.3.6.1.4.1.164.3.3.3.1.4.2.1.1Integer32read-onlyThis attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
OCT prtAlrMask1.3.6.1.4.1.164.3.3.3.1.4.2.1.2OCTET STRINGread-writeThis object is a mask that indicates which port level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the port level will be 0. This object is applicable only when prtGenAlrMaskAll=off (otherwise all port alarms are masked). Example: When Alarms having the codes 31 and 40 are masked, the value of this object will be 10080000000 (hex).
prtBertTable1.3.6.1.4.1.164.3.3.3.1.5not-accessibleThis table includes the BERT parameters, counters and commands. The configurable parameters: - prtBertPattern - prtBertInjectRate - prtBertTs are not Set per configuration (same for all Configurations) but start being applied by the Agent only upon successful Update/Download operation. Therefore, Set will enter the values to the Temporary Configuration of the agent, while Get will get the values of the Active Configuration.
prtBertEntry1.3.6.1.4.1.164.3.3.3.1.5.1not-accessibleAn entry in table.
I32 prtBertPrtIdx1.3.6.1.4.1.164.3.3.3.1.5.1.1Integer32read-onlyThis attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . In the MP : - first two digits will be: (IO slot number+10) - last one/two digits will be according to the external port number within the card: exPrt1 -> 1 exPrt2 -> 3 exPrt3 -> 5 exPrt4 -> 7 .
INT prtBertPattern1.3.6.1.4.1.164.3.3.3.1.5.1.2INTEGERread-writeThis object indicates the pattern of the BERT. p2Exxm1 = 2Exx-1. pxx = pattern xx. This object is the same for all configurations. notApplicable - when this object is not supported.
INT prtBertInjectRate1.3.6.1.4.1.164.3.3.3.1.5.1.3INTEGERread-writeThis object indicates the error rate injection of the BERT. r10Emx = 10E-x This object is the same for all configurations. single - single error injection. notApplicable - when this object is not supported.
INT prtBertInjectErrRateCmd1.3.6.1.4.1.164.3.3.3.1.5.1.4INTEGERread-writeThis object controls activation/deactivation of the Error Rate Injection during BERT.
INT prtBertInjectSingleErrCmd1.3.6.1.4.1.164.3.3.3.1.5.1.5INTEGERread-writeThis object enables to initiate a Single Error Injection during BERT (on). Upon completion, the value will automatically change to off(2).
I32 prtBertRunTime1.3.6.1.4.1.164.3.3.3.1.5.1.6Integer32read-onlyThis object indicates how much time (seconds) passed since BERT started to run.
I32 prtBertESs1.3.6.1.4.1.164.3.3.3.1.5.1.7Integer32read-onlyHow many Errored Seconds were detected since BERT started to run. Counter for Kmux and MP.
I32 prtBertSyncLoss1.3.6.1.4.1.164.3.3.3.1.5.1.8Integer32read-onlyHow many times Sync Loss was detected since BERT started to run. For some products: number of seconds in which Sync Loss occured since BERT started to run. See product specification.
I32 prtBertErrorBits1.3.6.1.4.1.164.3.3.3.1.5.1.9Integer32read-onlyHow many Error Bits were detected since BERT started to run.
INT prtBertClearCounters1.3.6.1.4.1.164.3.3.3.1.5.1.10INTEGERread-writeSetting this object to ON, will enforce a clear operation of some BERT Counters. Upon completion, the value will automatically change to off(2).
INT prtBertSyncStatus1.3.6.1.4.1.164.3.3.3.1.5.1.11INTEGERread-onlySync Status while BERT runs.
OCT prtBertTs1.3.6.1.4.1.164.3.3.3.1.5.1.12OCTET STRINGread-writeThis object indicates on which TSs of the selected port, BERT should be applied. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - BERT should be applied on this TS. For a T1 port, the valid raised bits ('1') are: 1..25. For an E1 port, the valid raised bits ('1') are: 1..31. Agents that do not support this feature will send SIZE 0.
STR prtBertResult1.3.6.1.4.1.164.3.3.3.1.5.1.13DisplayStringread-onlyThis object indicates Result of BERT for the selected port (number of error bits divided to the total number of data bits.) Applicable only if BERT is running on this port Agents that do not support this feature will send SIZE 0.
I32 prtBertTxBits1.3.6.1.4.1.164.3.3.3.1.5.1.14Integer32read-onlyHow many data bits were transmitted since BERT started to run, or since last counter clear (prtBertClearCounters set to on).
I32 prtBertRxBits1.3.6.1.4.1.164.3.3.3.1.5.1.15Integer32read-onlyHow many data bits were Received since BERT started to run, or since last counter clear (prtBertClearCounters set to on).
I32 prtBertTxErrorBits1.3.6.1.4.1.164.3.3.3.1.5.1.16Integer32read-onlyNumber of injected error bits since BERT started to run, or since last counter clear (prtBertClearCounters set to on).
prtMonTable1.3.6.1.4.1.164.3.3.3.1.6not-accessibleFor DXC, the write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch).
prtMonEntry1.3.6.1.4.1.164.3.3.3.1.6.1not-accessibleAn entry in table.
I32 prtMonCnfgIdx1.3.6.1.4.1.164.3.3.3.1.6.1.1Integer32read-onlyThis object indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg. For products that do not support configurations, 1 will be always used.
I32 prtMonitoringIdx1.3.6.1.4.1.164.3.3.3.1.6.1.2Integer32read-onlyThis object indicates the Monitoring Port Index. For DXC: The valid port number depends on the IO slot no., the installed card type and the port type: external, internal. * The external ports will according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The internal ports will be according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For Optimux-T3: 255 (Not Applicable) will be always used. The Monitoring port is always the Station Clock (not considered an interface).
INT prtMonitoringEnable1.3.6.1.4.1.164.3.3.3.1.6.1.3INTEGERread-writeThis object indicates if the prtMonitoringIdx is configured as a monitoring port or not. disabled = the port is NOT configured to monitor. Setting this object to this value will cause reset (to 0) of the prtMonitoringTSs and prtMonitoredTSs objects. enabled = the port IS configured to monitor. For Optimux-T3: always enabled (RO supported).
OCT prtMonitoringTSs1.3.6.1.4.1.164.3.3.3.1.6.1.4OCTET STRINGread-writeThis object indicates which TSs of the Monitoring port, the test equipment should monitor. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - this TS should be monitored. For a T1 port, the valid raised bits ('1') are: 1..24. For an E1 port, the valid raised bits ('1') are: 1..31. Default: all bits='0' Agents that do not support this feature will send SIZE 0. This object can be Set as described only if prtMonitoringEnable=enabled.
I32 prtMonitoredPort1.3.6.1.4.1.164.3.3.3.1.6.1.5Integer32read-writeThis object indicates the MONITORED Port Index that the Monitoring port monitors. For DXC: The valid port number depends on the IO slot no., the installed card type and the port type: external, internal. * The external ports will according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The internal ports will be according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . * 100 - no port monitored For Optimux-T3: The valid channels are: 0 = no Ch monitored 1..21 or 1..28 (=CH1..CH21 or CH1..CH28) according to product's configuration.
OCT prtMonitoredTSs1.3.6.1.4.1.164.3.3.3.1.6.1.6OCTET STRINGread-writeThis object indicates which TSs of the Monitored port, should be monitored. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - this TS should be monitored. For a T1 port, the valid raised bits ('1') are: 1..24. For an E1 port, the valid raised bits ('1') are: 1..31. Default: all bits='0' Agents that do not support this feature will send SIZE 0. This object can be Set as described only if prtMonitoringEnable=enabled.
prtCfgParam1.3.6.1.4.1.164.3.3.3.1.7
prtCfgParamTable1.3.6.1.4.1.164.3.3.3.1.7.1not-accessibleThe write operation into the Table Objects is valid only to the TmpCnfg entry. KMUX parameters are for the cards: KMBE/New, KVF.6 family.
prtCfgParamEntry1.3.6.1.4.1.164.3.3.3.1.7.1.1not-accessibleAn entry in table.
I32 prtCfgParamCnfgIdx1.3.6.1.4.1.164.3.3.3.1.7.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
I32 prtCfgParamIdx1.3.6.1.4.1.164.3.3.3.1.7.1.1.2Integer32read-onlyA unique identifier of the port (within the card when applicable). - For KM-2100: Slot*100+Ch external ports: Ch=1..10 internal ports (sub-channels): Ch=11..20. - For FCD-T1/E1(L): MAIN=111, SUB=113, CH1=122, CH2=124. - For other devices, see specific device's spec.
INT prtCfgParamSlt1.3.6.1.4.1.164.3.3.3.1.7.1.1.3INTEGERread-onlyThis attribute indicates a unique number to identify the slot where the card is inserted in. In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid. notApplicable(255) - for products that do not have Slots.
INT prtCfgParamOperatedMl1.3.6.1.4.1.164.3.3.3.1.7.1.1.4INTEGERread-writeThe main link for this channel. The field is relevant only for ML modes of Dual, Priority Bumping and Switched Backup.
INT prtCfgParamMlAtoMlBPrio1.3.6.1.4.1.164.3.3.3.1.7.1.1.5INTEGERread-writeML-A to ML-B Priority. The field is relevant only for ML modes of Priority Bumping and Switched Backup.
INT prtCfgParamMlBtoMlAPrio1.3.6.1.4.1.164.3.3.3.1.7.1.1.6INTEGERread-writeML-B to ML-A Priority. The field is relevant only for ML modes of Priority Bumping.
INT prtCfgParamInbandLoopDetection1.3.6.1.4.1.164.3.3.3.1.7.1.1.7INTEGERread-writeInband Loop Detection. The field is relevant for FCD-T1/E1(L) ports.
INT prtCfgParamInbandLoopPatternCfg1.3.6.1.4.1.164.3.3.3.1.7.1.1.8INTEGERread-writeThis object indicates if Inband Loop polynomial pattern will be according to RDL Loop (the standard) or User Configurated according to prtCfgParamInbandLoopActPattern and prtCfgParamInbandLoopDeactPattern.
STR prtCfgParamInbandLoopActPattern1.3.6.1.4.1.164.3.3.3.1.7.1.1.9DisplayStringread-writeThis object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1' characters are valid. The string determines coefficients of the polynomial pattern sent to the port in order to Activate the Inband Loop. This object is relevant only when prtCfgParamInbandLoopPatternCfg=userConfig.
STR prtCfgParamInbandLoopDeactPattern1.3.6.1.4.1.164.3.3.3.1.7.1.1.10DisplayStringread-writeThis object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1' characters are valid. The string determines coefficients of the polynomial pattern sent to the port in order to Deactivate the Inband Loop. This object is relevant only when prtCfgParamInbandLoopPatternCfg=userConfig.
prtT1E11.3.6.1.4.1.164.3.3.3.2
prtT1E1StatTable1.3.6.1.4.1.164.3.3.3.2.1not-accessibleT1/E1 port statistics table.
prtT1E1StatEntry1.3.6.1.4.1.164.3.3.3.2.1.1not-accessibleAn entry in the T1/E1 port statistics table.
I32 prtT1E1SPrtIdx1.3.6.1.4.1.164.3.3.3.2.1.1.1Integer32read-onlyThis attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 .
INT prtT1E1SSlt1.3.6.1.4.1.164.3.3.3.2.1.1.2INTEGERread-onlyThis attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
G32 prtT1E1OosCount1.3.6.1.4.1.164.3.3.3.2.1.1.3Gauge32read-onlyThis object is applicable only for an E1 active port. It provides the number of red alarm events since the last count clearing.
G32 prtT1E1BpvLastMin1.3.6.1.4.1.164.3.3.3.2.1.1.4Gauge32read-onlyThis object is applicable only for an E1 active port. It provides the number of BPV (BiPolar Violation) events detected during the last minute.
G32 prtT1E1BpvMax1.3.6.1.4.1.164.3.3.3.2.1.1.5Gauge32read-onlyThis object is applicable only for an E1 active port. It provides the maximal number of BPV (BiPolar Violation) events (per minute), detected during the worst minute.
prtT1E1CnfgTable1.3.6.1.4.1.164.3.3.3.2.2not-accessibleT1/E1 port configuration table.
prtT1E1CnfgEntry1.3.6.1.4.1.164.3.3.3.2.2.1not-accessibleAn entry in the T1/E1 port configuration table.
I32 prtT1E1CnfgIdx1.3.6.1.4.1.164.3.3.3.2.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config.
I32 prtT1E1PrtIdx1.3.6.1.4.1.164.3.3.3.2.2.1.2Integer32read-onlyThis attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20.
INT prtT1E1Slt1.3.6.1.4.1.164.3.3.3.2.2.1.3INTEGERread-onlyThis attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
INT prtT1E1LineType1.3.6.1.4.1.164.3.3.3.2.2.1.4INTEGERread-writeThis variable indicates the variety of T1/E1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: TITLE: SPECIFICATION: esf Extended SuperFrame DS1 d4 AT&T D4 format DS1 - SF e1 CCITT Recommendation G.704 (Table 4a) - G732N e1Crc CCITT Recommendation G.704 (Table 4b) - G732N with CRC e1MF G.704 (Table 4a) with TS16 multiframing enabled - G732S e1CrcMF G.704 (Table 4b) with TS16 multiframing enabled - G732S with CRC unframed T1 - applicable values: (1),(2),(3),(8) E1 - applicable values: (1),(4),(5),(6),(7),(8)
INT prtT1E1LineCode1.3.6.1.4.1.164.3.3.3.2.2.1.5INTEGERread-writeThis variable describes the variety of Zero Code Suppression used on the link, which in turn affects a number of its characteristics. jbzs=b7zs refers the Jammed Bit Zero Suppres- sion, in which the AT&T specification of at least one pulse every 8 bit periods is literal- ly implemented by forcing a pulse in bit 8 of each channel. Thus, only seven bits per chan- nel, or 1.344 Mbps, is available for data (used for T1). b8zs refers to the use of a specified pattern of normal bits and bipolar violations which are used to replace a sequence of eight zero bits (used for T1). ANSI Clear Channels may use zbtsi, or Zero Byte Time Slot Interchange. E1 links, with or without CRC, use hdb3 or ami (= TRAN). amI (=TRAN) refers to a mode wherein no zero code suppression is present and the line encoding does not solve the problem directly. In this application, the higher layer must provide data which meets or exceeds the pulse density re- quirements, such as inverting HDLC data.
INT prtT1E1SignalMode1.3.6.1.4.1.164.3.3.3.2.2.1.6INTEGERread-write'none' indicates that no bits are reserved for signaling on this channel. 'robbedBit' indicates that T1 Robbed Bit Signaling is in use. 'bitOriented' indicates that E1 Channel Associated Signaling (CAS) is in use. 'messageOriented' indicates that Common Channel Signaling (CCS) is in use either on channel 16 of an E1 link or channel 24 of a T1.
INT prtT1E1Fdl1.3.6.1.4.1.164.3.3.3.2.2.1.7INTEGERread-writeThis bitmap describes the use of the facili- ties data link, and is the sum of the capabili- ties: 'other' indicates that a protocol other than one following is used. 'ansi-T1-403' refers to the FDL exchange recommended by ANSI. 'att-54016' refers to ESF FDL exchanges. 'fdl-none' indicates that the device does not use the FDL. 'transFdl' indicates transition between two ports of the same card.
INT prtT1E1FdlMode1.3.6.1.4.1.164.3.3.3.2.2.1.8INTEGERread-writeFdl Mode of the T1 selected port. notApplicable - will be used for an E1 port.
INT prtT1E1Sync1.3.6.1.4.1.164.3.3.3.2.2.1.9INTEGERread-writeThis object enables returning to normal operation, after the end of a main/sub link red alarm event, in reduced time. 'tr62411' - complies with AT&T TR-62411 (after 10 seconds). Applicable for both T1 and E1 interfaces. 'ccitt' - complies with CCITT standard. Applicable only for E1 interfaces. 'fast' - after 1 second.
INT prtT1E1CGA1.3.6.1.4.1.164.3.3.3.2.2.1.10INTEGERread-writeThis object selects the method used to signal the CGA state to the other end, through the main/sub link. 'none' - non-transparent mode. When one of the links (main/sub) will be in Out Of Service state, both 'Data/Voice Oos' and 'Oos Signal' will be transmitted to the other end. 'trans' - when one of the links (main/sub) will be in Out Of Service state, 'Data/Voice Oos' will be transmitted to the other end. 'full' - fully-transparent mode. When one of the links (main/sub) will be in Out Of Service state, neither 'Data/Voice Oos' nor 'Oos Signal' will be transmitted to the other end.
OCT prtT1E1IdleCode1.3.6.1.4.1.164.3.3.3.2.2.1.11OCTET STRINGread-writeThis object selects the code transmitted to fill idle (unused) time slots in the main link frame. Valid range: (0 - FF HEX) .
INT prtT1E1OosSignal1.3.6.1.4.1.164.3.3.3.2.2.1.12INTEGERread-write'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. 'busyIdle' = MK_SP = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. 'idleBusy' = SP_MK = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0
OCT prtT1E1VoiceOos1.3.6.1.4.1.164.3.3.3.2.2.1.13OCTET STRINGread-writeVoice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
OCT prtT1E1DataOos1.3.6.1.4.1.164.3.3.3.2.2.1.14OCTET STRINGread-writeData Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
INT prtT1E1LineLengthMask1.3.6.1.4.1.164.3.3.3.2.2.1.15INTEGERread-writeThis attribute is the line length mask parameter used only for T1/DSU interfaces. len400p533ft=length range: 400ft to 533ft 'fcc68' - provides compliance with the FCC 68.308 Option A output pulse mask.
INT prtT1E1TxGainMask1.3.6.1.4.1.164.3.3.3.2.2.1.16INTEGERread-writeThis attribute is the tx gain mask parameter (dB), used only for T1/CSU interfaces.
INT prtT1E1InbandMng1.3.6.1.4.1.164.3.3.3.2.2.1.17INTEGERread-writeA unique number to identify an Inband management over the link. internal - supported by KM-2100 only. It means that the management is internal to the frame. It takes part of the ML Frame bits (instead of data).
INT prtT1E1InbandMngRate1.3.6.1.4.1.164.3.3.3.2.2.1.18INTEGERread-writeA unique number to identify the rate of the Inband management. It is required only for E1 links and is applicable only when prtExT1E1InbandMng selected is FdlOrTs0 or dedicatedTs.
I32 prtT1E1DedicatedTs1.3.6.1.4.1.164.3.3.3.2.2.1.19Integer32read-writeThe value is differently determined for different products. There are two methods: 1) A unique number to identify Dedicated TS of the T1/E1 port. It is applicable only when prtExT1E1InbandMng selected is dedicatedTs. 1..24 - Dedicated TS of T1 1..31 - Dedicated TS of E1 255 - notApplicable (for agents that do not support this feature) Other values are invalid. 2) For FCD-STM, up to five TSs may be dedicated to management. This object value is the Sum (sigma) of 2**n, where n =TS-1 e.g. Time slots 3,5,7,9,11 are dedicated to management: 2** 2 +2** 4 +2** 6 +2** 8 +2**10 = 4+16+64+256+1024=1364 User should consult the product specification, to find out the method employed.
INT prtT1E1InbandMngRoutProt1.3.6.1.4.1.164.3.3.3.2.2.1.20INTEGERread-writeInband Mng Routing Protocol of the port. When prtT1E1InbandMng is 'dedicatedPpp'-'proprietary' and 'rip2' are applicable. For other values - only 'proprietary' is applicable. For FCD-M and FCD-A: When prtT1E1InbandMng is 'dedicatedPpp' or 'dedicatedFr': 'None', 'proprietary' and 'rip2' are applicable. When prtT1E1InbandMng is 'fdlOrTS0' or 'dedicatedTs': 'None' and 'proprietary' are applicable. When prtT1E1InbandMng is 'off': 'None' is applicable.
INT prtT1E1LinkMode1.3.6.1.4.1.164.3.3.3.2.2.1.21INTEGERread-writeregular - TSs are connected by user via TS Assignment only transparent - when a port with this Link Mode is connected to an internal T1/E1 port of a T3/E3 card, TS0, TS16 and Fbit are transparently transferred to the E3/T3 stream.
INT prtT1E1Multiplier1.3.6.1.4.1.164.3.3.3.2.2.1.22INTEGERread-writeThe data rate of each TS. The multiplier values can be 56 kbps or 64 kbps. For T1 only.
INT prtT1E1RxGain1.3.6.1.4.1.164.3.3.3.2.2.1.23INTEGERread-writeThis attribute is the rx volume (dB).
INT prtT1E1RAI1.3.6.1.4.1.164.3.3.3.2.2.1.24INTEGERread-writeRemote Alarm Signal
INT prtT1E1LineMode1.3.6.1.4.1.164.3.3.3.2.2.1.25INTEGERread-writeInterface type of the port. For T1 - csu, dsu are the valid values For E1 - dsu, ltu are the valid values
OCT prtT1E1TS0SaBits1.3.6.1.4.1.164.3.3.3.2.2.1.26OCTET STRINGread-writeThis object is applicable only for E1 ports. For T1, string size will be 0. For E1, it enables user to select the use of TS0 Sa Bits 4..8, by 3 octets: The order (in hexa display): free Sa-Bit-4 Sa-Bit-5 Sa-Bit-6 Sa-Bit-7 Sa-Bit-8 |___________| |________________| |________________| MSByte LSByte Each Sa Bit will be represented by a nibble, having the following meaning: 0000 = zero 0001 = one 0010 = management 0011 = transparent the rest are reserved for future use.
INT prtT1E1ConnectedTS1.3.6.1.4.1.164.3.3.3.2.2.1.27INTEGERread-onlyThis parameter indicates if there is any connected TS for this interface.
INT prtT1E1Ts0SaBit1.3.6.1.4.1.164.3.3.3.2.2.1.28INTEGERread-writeThis parameter indicates whether to send TS 0, or not. noMng= TS 0 is looped, therefore not sent. mng= TS 0 isn't looped, therefore it is sent.
INT prtT1E1SameFeCnfg1.3.6.1.4.1.164.3.3.3.2.2.1.29INTEGERread-writeThis parameter indicates whether the same E1 configuration parameters and TS assignment are set both to the local and remote device. Read-Write access is applicable only in G732N framed mode. For G732S and UNFRAMED this parameter is set by agent to YES and is Read Only. In Case of conflict during power-up between the central and remote, the value set by the central unit is the valid one.
INT prtT1E1RemCrc41.3.6.1.4.1.164.3.3.3.2.2.1.30INTEGERread-writeThis object indicates whether the E1 of the Remote device connected to this E1 port, will have CRC-4 or not.
I32 prtT1E1MaxTSs1.3.6.1.4.1.164.3.3.3.2.2.1.31Integer32read-writeThis object is applicable only for DXC D4T1, D4E1, D8T1, D8E1 external ports and D8GSL internal E1 ports. It is relevant only when sysCIntTsAllocMode=static(2). 255=not applicable If prtT1E1LineType=unframed(8), the value of this object must be 32. Else, the valid values are 0..31.
INT prtT1E1EocTsConfig1.3.6.1.4.1.164.3.3.3.2.2.1.32INTEGERread-writeThis object indicates whether the use of EOC for TS Configuration is enabled or not.
INT prtT1E1Role1.3.6.1.4.1.164.3.3.3.2.2.1.33INTEGERread-writeThis object indicates whether this port behaves as SUB or Main link.
INT prtT1E1PppEchoFailDetection1.3.6.1.4.1.164.3.3.3.2.2.1.34INTEGERread-writeThis object indicates whether the PPP Echo is taken into account for its Fail Detection. This object is relevant when Inband Mng between devices is Dedicated TS PPP. Default=Disable. Enable - will be selected mainly when a T1/E1 Ring exists and between 2 adjacent Ring devices there is another device or Net, that causes these Ring devices not to sense that the PPP connection between them is lost. In this case, Echo Request should be initiated by the port.
prtT1E1FdlMsgTable1.3.6.1.4.1.164.3.3.3.2.3not-accessibleThis table is applicable for a T1 interface with 'esf' LineType or E1 interface, when CRC is enabled (LineType).
prtT1E1FdlMsgEntry1.3.6.1.4.1.164.3.3.3.2.3.1not-accessibleAn entry in table.
I32 prtT1E1FdlMsgPrtIdx1.3.6.1.4.1.164.3.3.3.2.3.1.1Integer32read-onlyThis attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 .
INT prtT1E1FdlMsgFdlType1.3.6.1.4.1.164.3.3.3.2.3.1.2INTEGERread-onlyThe Fdl type reference of the Fdl message.
INT prtT1E1FdlMsgSlt1.3.6.1.4.1.164.3.3.3.2.3.1.3INTEGERread-onlyThis attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
OCT prtT1E1FdlMsg1.3.6.1.4.1.164.3.3.3.2.3.1.4OCTET STRINGread-onlyFDL message.
prtHS1.3.6.1.4.1.164.3.3.3.3
prtHSParamTable1.3.6.1.4.1.164.3.3.3.3.1not-accessibleA table.
prtHSParamEntry1.3.6.1.4.1.164.3.3.3.3.1.1not-accessibleAn entry in table.
I32 prtHSCnfgIdx1.3.6.1.4.1.164.3.3.3.3.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config.
I32 prtHSPrtIdx1.3.6.1.4.1.164.3.3.3.3.1.1.2Integer32read-onlyThis attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
INT prtHSSlt1.3.6.1.4.1.164.3.3.3.3.1.1.3INTEGERread-onlyThis attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
INT prtHSRate1.3.6.1.4.1.164.3.3.3.3.1.1.4INTEGERread-writeThis object indicates the port rate (speed). auto - rate is selected automatically by system.
INT prtHSFifoSize1.3.6.1.4.1.164.3.3.3.3.1.1.5INTEGERread-writeThis object selects the size of the user data channel buffer FIFO used in the DTE2 mode. In the other modes, buffer size is automatically set by the DACS agent. Buffer FIFO size in bits, corresponds to FIFO lengths of +/-16, +/-30, +/-52, +/-72 bits.
INT prtHSClkMode1.3.6.1.4.1.164.3.3.3.3.1.1.6INTEGERread-writeClock Mode of the user data channel. dce - DACS operates as a DCE and provides transmit and receive clocks to the synchronous user DTE. dte1- DACS supplies the receive clock to the user equipment and accepts the user transmit clock. dte2- DACS requires transmit and receive clocks from the user equipment.
INT prtHSCTS1.3.6.1.4.1.164.3.3.3.3.1.1.7INTEGERread-writeSelection of CTS line state in the user data channel. on - CTS continuously ON. rts - CTS line follows the RTS line.
INT prtHSRtsState1.3.6.1.4.1.164.3.3.3.3.1.1.8INTEGERread-onlyRTS state of the port.
INT prtHSInbandLoopback1.3.6.1.4.1.164.3.3.3.3.1.1.9INTEGERread-writeThis object indicates if Inband Loopback from the Network should be enabled or disabled.
INT prtHSInbandLoopPatternCfg1.3.6.1.4.1.164.3.3.3.3.1.1.10INTEGERread-writeThis object indicates if Inband Loop polynomial pattern will be according to RDL Loop (the standard) or User Configurated according to prtHSActivatePolyPattern and prtHSDeactivatePolyPattern.
STR prtHSInbandLoopActPattern1.3.6.1.4.1.164.3.3.3.3.1.1.11DisplayStringread-writeThis object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1' characters are valid. The string determines coefficients of the polynomial pattern sent to the port in order to Activate the Inband Loop. This object is relevant only when prtHSInbandLoopPatternCfg=userConfig.
STR prtHSInbandLoopDeactPattern1.3.6.1.4.1.164.3.3.3.3.1.1.12DisplayStringread-writeThis object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1' characters are valid. The string determines coefficients of the polynomial pattern sent to the port in order to Deactivate the Inband Loop. This object is relevant only when prtHSInbandLoopPatternCfg=userConfig.
INT prtHSDCD1.3.6.1.4.1.164.3.3.3.3.1.1.13INTEGERread-writeSelection of DCD line state in the user data channel. linkOK - DCD line is ON only when active link is OK. on - DCD continuously ON.
INT prtHSClkPolarity1.3.6.1.4.1.164.3.3.3.3.1.1.14INTEGERread-writeThis object indicates the clock polarity.
INT prtHSInterfaceType1.3.6.1.4.1.164.3.3.3.3.1.1.15INTEGERread-writeThis object indicates the selected electrical interface type.
INT prtHSUnframed1.3.6.1.4.1.164.3.3.3.3.1.1.16INTEGERread-writeUnframed line for HS ports. yes - means that all TSs must be transferred, including TS0. In this case, prtHSRate must be r31x56eq1736Kbps OR r31x64eq1984Kbps.
prtHSBertTable1.3.6.1.4.1.164.3.3.3.3.2not-accessibleA table.
prtHSBertEntry1.3.6.1.4.1.164.3.3.3.3.2.1not-accessibleAn entry in table.
I32 prtHSBertPrtIdx1.3.6.1.4.1.164.3.3.3.3.2.1.1Integer32read-onlyThis attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
INT prtHSBertSlt1.3.6.1.4.1.164.3.3.3.3.2.1.2INTEGERread-onlyThis attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
INT prtHSBertCountClr1.3.6.1.4.1.164.3.3.3.3.2.1.3INTEGERread-writeSetting this object (to on) initiate bert counter clear operation. Valid only when bert test is active on the specific port. (Every time a new bert test starts, the counter is automatically cleared; this command enables clearing the counter while the test is running).
I32 prtHSBertTestResult1.3.6.1.4.1.164.3.3.3.3.2.1.4Integer32read-onlyThis object indicates the number of Bit Error Rate indicated during the BERT test. Active only when bert test is running on the selected port.
prtSP1.3.6.1.4.1.164.3.3.3.4
prtSpCnfgTable1.3.6.1.4.1.164.3.3.3.4.1not-accessibleA table.
prtSpCnfgEntry1.3.6.1.4.1.164.3.3.3.4.1.1not-accessibleAll the entries at this table are identical(have the same value) at all the configurations(1..255) except at the TmpCnfg. - For products supporting more than one configuration, the write operation into the Table Objects is valid only at the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table Objects will be to prtSpCnfgIdx=1.
I32 prtSpCnfgIdx1.3.6.1.4.1.164.3.3.3.4.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
I32 prtSpPrtIdx1.3.6.1.4.1.164.3.3.3.4.1.1.2Integer32read-onlyThis attribute indicates a unique port number of the SPor DP port. For DXC, it is the port in the active DCL card: - SP = 1 - NP ; DP = 2 For Kilomux, the port index is calculated as follows: 100*Slot+Ch. For FCD, PRBi, the SP port index=1. For Optimux-T3, the SP port index=71.
INT prtSpUsage1.3.6.1.4.1.164.3.3.3.4.1.1.3INTEGERread-writeThis attribute indicates what is the usage of the port.
INT prtSpRate1.3.6.1.4.1.164.3.3.3.4.1.1.4INTEGERread-writeThis attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent.
INT prtSpDataBits1.3.6.1.4.1.164.3.3.3.4.1.1.5INTEGERread-writeThis attribute indicates the number of data bits in async frame
INT prtSpParity1.3.6.1.4.1.164.3.3.3.4.1.1.6INTEGERread-writeThis attribute indicates the parity mode in async frame
INT prtSpCallOutMode1.3.6.1.4.1.164.3.3.3.4.1.1.7INTEGERread-writeThis attribute indicates the call-out mode. For DXC - this object is applicable only for the DP port (2).
INT prtSpInterface1.3.6.1.4.1.164.3.3.3.4.1.1.8INTEGERread-writeThis attribute indicates the supervisory port interface. dce - the DACS appears as a DCE for the port. dte - the DACS operates as a DTE, for connection via modem, for the port.
INT prtSpCTS1.3.6.1.4.1.164.3.3.3.4.1.1.9INTEGERread-writeCTS line state. This object is applicable only for port (1) = SP
INT prtSpDcdDelay1.3.6.1.4.1.164.3.3.3.4.1.1.10INTEGERread-writeDCD delay in msec. d10 = delay of 10msec. This object is applicable only for port (1) = SP
INT prtSpDsr1.3.6.1.4.1.164.3.3.3.4.1.1.11INTEGERread-writeDSR line state. This object is applicable only for port (1) = SP
I32 prtSpNoOfRetries1.3.6.1.4.1.164.3.3.3.4.1.1.12Integer32read-writeFor DXC - this object is applicable only for port (2) = DP. The number of dialing retries requested. Default = 0
INT prtSpWaitForConnect1.3.6.1.4.1.164.3.3.3.4.1.1.13INTEGERread-writeFor DXC - this object is applicable only for port (2) = DP. Waiting time for connect, in seconds. Default = 30 sec.
INT prtSpDialMode1.3.6.1.4.1.164.3.3.3.4.1.1.14INTEGERread-writeFor DXC - this object is applicable only for port (2) = DP. Dialing mode. Default=tone
INT prtSpAltNumMode1.3.6.1.4.1.164.3.3.3.4.1.1.15INTEGERread-writeFor DXC - this object is applicable only for port (2) = DP. It determines wether to use the alternate number or not. Default = no.
STR prtSpPrimaryNum1.3.6.1.4.1.164.3.3.3.4.1.1.16DisplayStringread-writeFor DXC - this object is applicable only for port (2) = DP. It is the Primary dialing number.
STR prtSpAltNum1.3.6.1.4.1.164.3.3.3.4.1.1.17DisplayStringread-writeFor DXC - this object is applicable only for port (2) = DP. It is the Alternate dialing number. This number is applicable only if prtSpAltNumMode is 'yes'.
INT prtSpRoutProtocol1.3.6.1.4.1.164.3.3.3.4.1.1.18INTEGERread-writeThis attribute indicates the routing protocol of the port. notApplicable - for DP.
OCT prtSpCmd1.3.6.1.4.1.164.3.3.3.4.1.1.19OCTET STRINGread-writeSP Command. For LRS this parameter will be used for a Modem Command. Upon NMS's Get operation for devices that this parameter is notApplicable, agent will send NULL string.
INT prtSpActCallOut1.3.6.1.4.1.164.3.3.3.4.1.1.20INTEGERread-writeThis object indicates when to Activate Call-Out. It is used by FCD-T1/E1. always - to activate call-out always. linkFail - to activate call-out only when Link of Inband Management fails.
INT prtSpAlrRelayMode1.3.6.1.4.1.164.3.3.3.4.1.1.21INTEGERread-writeThis attribute indicates the Alarm Relay Mode. notApplicable - for DP.
INT prtSpStopBits1.3.6.1.4.1.164.3.3.3.4.1.1.22INTEGERread-writeThis attribute indicates number of stop bits in an async frame.
prtDim1.3.6.1.4.1.164.3.3.3.5
prtDimCnfgTable1.3.6.1.4.1.164.3.3.3.5.1not-accessibleA table.
prtDimCnfgEntry1.3.6.1.4.1.164.3.3.3.5.1.1not-accessibleThe write operation into the Table Objects is valid only for the TmpCnfg entry (prtDimCnfgIdx=255).
I32 prtDimCnfgIdx1.3.6.1.4.1.164.3.3.3.5.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
I32 prtDimIdx1.3.6.1.4.1.164.3.3.3.5.1.1.2Integer32read-onlyThis attribute indicates a unique port number of the DIM card. The convention used for DXC: (IO slot number+10)*10 + 1 Example: port1 of IO slot 11 will be: 211 .
INT prtDimTxMode1.3.6.1.4.1.164.3.3.3.5.1.1.3INTEGERread-writeTx mode. regularTx - the links are connected to a similar outfit on the other side. In this mode, if a link fails, the transmitted bandwidth is decreased accordingly. broadcast - the links are connected to MORE than one similar outfit on the other side. In this mode, if a link fails, the transmitted bandwidth is not affected
INT prtDimPolarity1.3.6.1.4.1.164.3.3.3.5.1.1.4INTEGERread-writePolarity.
INT prtDimClkMode1.3.6.1.4.1.164.3.3.3.5.1.1.5INTEGERread-writeClock Mode. smooth - a clock that is not 'pulsed'(has no 'gaps'). In this mode the DXC does NOT receive back the clock signal. extSmooth - same as 'smooth' but in this mode, the DXC receives back the clock signal.
INT prtDimMaxDelay1.3.6.1.4.1.164.3.3.3.5.1.1.6INTEGERread-writeMax Delay permitted between the links, in msec.
INT prtDimMng1.3.6.1.4.1.164.3.3.3.5.1.1.7INTEGERread-writeUse of DIM port for management. disabled - no management on DIM ts1 - 1 bit of TS1 is used for management.
INT prtDimMngRoutProt1.3.6.1.4.1.164.3.3.3.5.1.1.8INTEGERread-writeMng Routing Protocol of the port. none - when prtDimMng is 'disabled'.
prtDimDestTable1.3.6.1.4.1.164.3.3.3.5.2not-accessibleA table.
prtDimDestEntry1.3.6.1.4.1.164.3.3.3.5.2.1not-accessibleThe write operation is valid only for the TmpCnfg entry (prtDimDestCnfgIdx=255).
I32 prtDestCnfgIdx1.3.6.1.4.1.164.3.3.3.5.2.1.1Integer32read-onlyThis attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
I32 prtDestDimIdx1.3.6.1.4.1.164.3.3.3.5.2.1.2Integer32read-onlyThis attribute indicates a unique port number of the DIM card. The convention used for DXC: (IO slot number+10) & 1 Example: port1 of IO slot 11 will be: 211 .
I32 prtDestIdx1.3.6.1.4.1.164.3.3.3.5.2.1.3Integer32read-onlyThis attribute indicates a destination number of the DIM card.
I32 prtDest1.3.6.1.4.1.164.3.3.3.5.2.1.4Integer32read-writeDestination port,(of a T1/E1 port), that is connected to the DIM card, for the specified Destination number. 0 = No destination port. Else: For external ports: (IO Slot+10) & 1 for port 1 (IO Slot+10) & 3 for port 2 Example: port2 of IO slot 12 will be: 223 . For internal ports : (IO Slot+10) & 2 for port 1 (IO Slot+10) & 4 for port 2 (IO Slot+10) & 6 for port 3 (IO Slot+10) & 8 for port 4, etc...
INT prtDestConnect1.3.6.1.4.1.164.3.3.3.5.2.1.5INTEGERread-onlyConnection Status of the specified destination number. For a specified destination port, it depends both on the status of the port and on the status of the far-end port. Since this is a RO object, same value will be received for all configurations.
prtI1.3.6.1.4.1.164.3.3.3.6
prtICnfgTable1.3.6.1.4.1.164.3.3.3.6.1not-accessibleA table.
prtICnfgEntry1.3.6.1.4.1.164.3.3.3.6.1.1not-accessibleAn entry in table.
I32 prtICnfgIdx1.3.6.1.4.1.164.3.3.3.6.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config.
I32 prtIIdx1.3.6.1.4.1.164.3.3.3.6.1.1.2Integer32read-onlyThis attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The ISDN B1, B2, D channels will be inside ports. For port index, see product specification.
INT prtIRate1.3.6.1.4.1.164.3.3.3.6.1.1.3INTEGERread-writeThis object indicates the port rate in bits. Each TS contains 8 bits. Thus, 1 bit is equivalent to 8Kbps rate.
INT prtIConnect1.3.6.1.4.1.164.3.3.3.6.1.1.4INTEGERread-writeD channel connection. no - disconnected yes - connected.
prtHdsl1.3.6.1.4.1.164.3.3.3.7
prtHdslTable1.3.6.1.4.1.164.3.3.3.7.1not-accessibleHDSL port table.
prtHdslEntry1.3.6.1.4.1.164.3.3.3.7.1.1not-accessibleAn entry in table.
I32 prtHdslIdx1.3.6.1.4.1.164.3.3.3.7.1.1.1Integer32read-onlyThis attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The HDSL ports will be external. For port index, see product specification.
INT prtHdslMode1.3.6.1.4.1.164.3.3.3.7.1.1.2INTEGERread-writeThis object indicates the HDSL mode.
INT prtHdslRptrType1.3.6.1.4.1.164.3.3.3.7.1.1.3INTEGERread-onlyThe Repeater between Near and Far modem. none - no repeater exists between the modems hrpt - HRPT repeater exists between the modems.
INT prtHdslMaxRate1.3.6.1.4.1.164.3.3.3.7.1.1.4INTEGERread-writeMaximum Rate of the xDSL Line, in Kbps units. This object can be Set only for a Central unit.
INT prtHdslLinkType1.3.6.1.4.1.164.3.3.3.7.1.1.5INTEGERread-onlyThe Link Type. msdsl2w - MSDSL 2 Wire hdsl2w - HDSL 2 Wire hdsl4w - HDSL 4 Wire gDsl - G.DSL
STR prtHdslCompSwVer1.3.6.1.4.1.164.3.3.3.7.1.1.6DisplayStringread-onlyThis object indicates the Software Version of the component (Piggyback card) supporting this interface.
STR prtHdslCompHwVer1.3.6.1.4.1.164.3.3.3.7.1.1.7DisplayStringread-onlyThis object indicates the Hardware Version of the component (Piggyback card) supporting this interface.
prtT3E31.3.6.1.4.1.164.3.3.3.8
prtT3E3CnfgTable1.3.6.1.4.1.164.3.3.3.8.1not-accessibleT3/E3 port configuration table.
prtT3E3CnfgEntry1.3.6.1.4.1.164.3.3.3.8.1.1not-accessibleAn entry in the T3/E3 port configuration table.
I32 prtT3E3CnfgIdx1.3.6.1.4.1.164.3.3.3.8.1.1.1Integer32read-onlyThis attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For DXC, write operations can be performed only on the Temp Config. For products that do not support configurations, always 1 will be used.
I32 prtT3E3PrtIdx1.3.6.1.4.1.164.3.3.3.8.1.1.2Integer32read-onlyThis attribute indicates a unique port number. For DXC: The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The external ports convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For Optimux-T3: Link-A: 51 Link-B: 61 .
INT prtT3E3Slt1.3.6.1.4.1.164.3.3.3.8.1.1.3INTEGERread-onlyThis attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
INT prtT3E3LineLength1.3.6.1.4.1.164.3.3.3.8.1.1.4INTEGERread-writeThis object is the length of the ds3 line in feet. It provides information for line build out circuitry if it exists and can use this object to adjust the line build out. len0p450ft = 0 - 450 feet len451p900ft = 451 - 900 feet.
INT prtT3E3InbandMng1.3.6.1.4.1.164.3.3.3.8.1.1.5INTEGERread-writeA unique number to identify the Frame Type over the link. For Optimux-T3: only values (4), (7) are supported.
INT prtT3E3AisFrame1.3.6.1.4.1.164.3.3.3.8.1.1.6INTEGERread-writeThis object is applicable only for Optimux-T3. It allows user to select whether the AIS sent will be framed or unframed.
INT prtT3E3TxClockSource1.3.6.1.4.1.164.3.3.3.8.1.1.7INTEGERread-writeTx Clock Source.
INT prtT3E3RoutProt1.3.6.1.4.1.164.3.3.3.8.1.1.8INTEGERread-writeRouting Protocol of the port. This object is applicable only for T3 ports.
INT prtT3E3AisTransmit1.3.6.1.4.1.164.3.3.3.8.1.1.9INTEGERread-writeIndicates if AIS signal will be transmitted over the tributary E3/DS3 upon failure.
genDacsMux1.3.6.1.4.1.164.3.3.4
cmprTable1.3.6.1.4.1.164.3.3.4.1not-accessibleA table.
cmprEntry1.3.6.1.4.1.164.3.3.4.1.1not-accessibleAn entry in table.
I32 cmprTypeIdx1.3.6.1.4.1.164.3.3.4.1.1.1Integer32read-onlyThis object indicates the Type of the Compressed data referred (which table, which level, etc). The type is a code according to a convention between agent and NMS.
I32 cmprCnfgIdx1.3.6.1.4.1.164.3.3.4.1.1.2Integer32read-onlyThis object indicates the configuration number the Compressed information relates to.
I32 cmprVersion1.3.6.1.4.1.164.3.3.4.1.1.3Integer32read-onlyThis object indicates the version of the internal format of the Compressed data (the version of the convention used).
INT cmprSltIdx1.3.6.1.4.1.164.3.3.4.1.1.4INTEGERread-onlyThis attribute indicates a unique number of the slot position where the card is inserted. When the unit is stand-alone or this object is not applicable, 255 will be used.
I32 cmprPrtIdx1.3.6.1.4.1.164.3.3.4.1.1.5Integer32read-onlyThis object indicates a unique identifier of the port, the compressed information relates to. For DXC - according to the order in the card of cmprSltIdx: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For FCD: see product's specification. If the port number is irrelevant to this parameter (if it is a system/card level alarm) the value will be 9999.
OCT cmprObj1.3.6.1.4.1.164.3.3.4.1.1.6OCTET STRINGread-writeThis object is the compressed information itself, according to a predefined format, both agent and NMS agreed about.
mapLinkTable1.3.6.1.4.1.164.3.3.4.2not-accessibleA table.
mapLinkEntry1.3.6.1.4.1.164.3.3.4.2.1not-accessibleAn entry in table.
I32 mapLinkIdx1.3.6.1.4.1.164.3.3.4.2.1.1Integer32read-onlyA unique identifier of the link
INT mapLinkSlotIdx1.3.6.1.4.1.164.3.3.4.2.1.2INTEGERread-writeThis attribute indicates a unique slot position where the module is inserted.
I32 mapLinkPortIdx1.3.6.1.4.1.164.3.3.4.2.1.3Integer32read-writeThis attribute indicates a unique port number. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
INT mapLinkState1.3.6.1.4.1.164.3.3.4.2.1.4INTEGERread-onlyThis attribute indicates the status of the link between the two muxes
alrGenTable1.3.6.1.4.1.164.3.3.4.3not-accessibleA table.
alrGenEntry1.3.6.1.4.1.164.3.3.4.3.1not-accessibleAn entry in table.
I32 alrGenCode1.3.6.1.4.1.164.3.3.4.3.1.1Integer32read-onlyThis object is a unique code number, identifying a certain alarm.
STR alrGenDescription1.3.6.1.4.1.164.3.3.4.3.1.2DisplayStringread-onlyThis entry is a unique text description, of the alarm corresponding to the specified code.
INT alrGenLevel1.3.6.1.4.1.164.3.3.4.3.1.3INTEGERread-onlyAlarm level.
INT alrGenSlotType1.3.6.1.4.1.164.3.3.4.3.1.4INTEGERread-onlySlot type that the alarm is relevant to. clAndIo - an alarm that is relevant for both CL and IO slots.
INT alrGenSeverity1.3.6.1.4.1.164.3.3.4.3.1.5INTEGERread-writeThis object enables the user to select a severity for each alarm. The severity is set per alarm code (same for all slots/ports using this code).
I32 alrGenDebounce1.3.6.1.4.1.164.3.3.4.3.1.6Integer32read-writeDebounce time for each alarm code, in seconds. The meaning is, that an alarm will be 'declared' as ON (or OFF), only after it was actually ON/OFF the Debouncing time selected by user. 0 = default debounce selection (each alarm has a default value). 250 = maximum value of seconds for debounce. 253 = mask = the alarm will Never be reported. 254 = default debounce selection (each alarm has a default value). 255 = not applicable
INT alrGenDefSeverity1.3.6.1.4.1.164.3.3.4.3.1.7INTEGERread-onlyThis object reports the default severity of each alarm. User can change the severity of the alarms defined by this default via the alrGenSeverity object.
radBridges1.3.6.1.4.1.164.4
genBridge1.3.6.1.4.1.164.4.1
INT radBridgeAction1.3.6.1.4.1.164.4.1.1INTEGERread-writeThis variable enables the operator to perform one of the specified actions on the tables maintained by the network device. Send actions are not currently implemented. Not all actions can be performed on all bridges.
I32 radBridgeInactiveArpTimeOut1.3.6.1.4.1.164.4.1.2Integer32read-writeThis variable defines the maximum time period that can pass between ARP requests concerning an entry in the ARP table. After this time period, the entry is deleted from the table.
radBridgeMaskTable1.3.6.1.4.1.164.4.1.3not-accessibleMask tables enable definition of forwarding restrictions and control of message flow in the internetwork. Each entry in this table defines a mask statement consisting of up to three mask definitions and an action defined by radBridgeMaskOper. Different types of mask entries are supported, as defined by radBridgeMaskType.
radBridgeMaskEntry1.3.6.1.4.1.164.4.1.3.1not-accessibleAn entry in table radBridgeMaskTable.
INT radBridgeMaskType1.3.6.1.4.1.164.4.1.3.1.1INTEGERread-onlyDefines the type of mask entry.
I32 radBridgeMaskIfIndex1.3.6.1.4.1.164.4.1.3.1.2Integer32read-onlySpecifies the if Index of the interface to which the mask is applied.
I32 radBridgeMaskNum1.3.6.1.4.1.164.4.1.3.1.3Integer32read-onlyThe Mask entry number, defined by its line number in the mask table.
INT radBridgeMaskDest1.3.6.1.4.1.164.4.1.3.1.4INTEGERread-writeSpecifies the type of destination address carried by the frame to which the mask will be applied. Unassigned-condition deactivates the mask entry.
OCT radBridgeMaskPat11.3.6.1.4.1.164.4.1.3.1.5OCTET STRINGread-writeDescribes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern.
OCT radBridgeMaskActiveBit11.3.6.1.4.1.164.4.1.3.1.6OCTET STRINGread-writeSpecifies the positions of the wild card characters (*) in the radBridgeMaskPat1 field.
INT radBridgeMaskFrom11.3.6.1.4.1.164.4.1.3.1.7INTEGERread-writeOffset base of radBridgeMaskPat1 within the frame. Net can be in some cases the data start point.
I32 radBridgeMaskOffset11.3.6.1.4.1.164.4.1.3.1.8Integer32read-writeSpecifies the radBridgeMaskPat1 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm1.The mask offset is an even decimal number in the range of 0 to 1518.
INT radBridgeMaskCond11.3.6.1.4.1.164.4.1.3.1.9INTEGERread-writeSpecifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset1 the packet contains data that matches the content of radBridgeMaskPat1. false - Condition is valid if at the position specified by radBridgeMaskOffset1 the packet contains data that does not match the content of radBridgeMaskPat1.
OCT radBridgeMaskPat21.3.6.1.4.1.164.4.1.3.1.10OCTET STRINGread-writeDescribes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern.
OCT radBridgeMaskActiveBit21.3.6.1.4.1.164.4.1.3.1.11OCTET STRINGread-writeSpecifies the positions of the wild card characters (*) in the radBridgeMaskPat2 field.
INT radBridgeMaskFrom21.3.6.1.4.1.164.4.1.3.1.12INTEGERread-writeOffset base of radBridgeMaskPat2 within the frame. Net can be in some cases the data start point.
I32 radBridgeMaskOffset21.3.6.1.4.1.164.4.1.3.1.13Integer32read-writeSpecifies the radBridgeMaskPat2 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm2.The mask offset is an even decimal number in the range of 0 to 1518.
INT radBridgeMaskCond21.3.6.1.4.1.164.4.1.3.1.14INTEGERread-writeSpecifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset2 the packet contains data that matches the content of radBridgeMaskPat2. false - Condition is valid if at the position specified by radBridgeMaskOffset2 the packet contains data that does not match the content of radBridgeMaskPat2.
OCT radBridgeMaskPat31.3.6.1.4.1.164.4.1.3.1.15OCTET STRINGread-writeDescribes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern.
OCT radBridgeMaskActiveBit31.3.6.1.4.1.164.4.1.3.1.16OCTET STRINGread-writeSpecifies the positions of the wild card characters (*) in the radBridgeMaskPat3 field.
INT radBridgeMaskFrom31.3.6.1.4.1.164.4.1.3.1.17INTEGERread-writeOffset base of radBridgeMaskPat3 within the frame. Net can be in some cases the data start point.
I32 radBridgeMaskOffset31.3.6.1.4.1.164.4.1.3.1.18Integer32read-writeSpecifies the radBridgeMaskPat3 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm3. The mask offset is an even decimal number in the range of 0 to 1518.
INT radBridgeMaskCond31.3.6.1.4.1.164.4.1.3.1.19INTEGERread-writeSpecifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset3 the packet contains data that matches the content of radBridgeMaskPat3 false - Condition is valid if at the position specified by radBridgeMaskOffset3 the packet contains data that does not match the content of radBridgeMaskPat3.
INT radBridgeMaskOper1.3.6.1.4.1.164.4.1.3.1.20INTEGERread-writeThe type of action to be taken if the frame meets the conditions of the mask. noOp = disabled (mask remains on list, but is not active) delete = mask is removed from the list.
radBridgeCOD1.3.6.1.4.1.164.4.1.4
radBridgeCODParamTable1.3.6.1.4.1.164.4.1.4.1not-accessibleThe table of COD parameters
radBridgeCODEntry1.3.6.1.4.1.164.4.1.4.1.1not-accessibleEach radBridgeCODEntry consists of the following parameters
I32 radBridgeCODIfIndex1.3.6.1.4.1.164.4.1.4.1.1.1Integer32read-onlyThe interface to which this COD entry is applicable.
INT radBridgeCODManualConnect1.3.6.1.4.1.164.4.1.4.1.1.2INTEGERread-writeThe management station can start connection manually by setting this parameter
INT radBridgeCODMode1.3.6.1.4.1.164.4.1.4.1.1.3INTEGERread-writeIn answer mode only one incoming call may be accepted at a time. Other nodes attempting to access the local modem will receive a busy signal until the connection is terminated. (Answer mode has no difficulty supporting multiple remote connections to one local port, as blocking multiple incoming calls is just a modem function. Originate mode, on the other hand will only support a single local port to remote port connection). The disable parameter disables the COD utility for this interface. Choosing any other mode will enable the COD utility.
I32 radBridgeCODConnectDelay1.3.6.1.4.1.164.4.1.4.1.1.4Integer32read-writeThe connect delay defines the minimum time period that the link must stay disconnected, between 2 succesive connections (in seconds).
I32 radBridgeCODisConnectDelay1.3.6.1.4.1.164.4.1.4.1.1.5Integer32read-writeThe disconnect delay defines the minimum time period the link must stay connected, between 2 succesive disconnections (in seconds).
INT radBridgeCODImplicitSwitch1.3.6.1.4.1.164.4.1.4.1.1.6INTEGERread-writeThe inplicit switch allows the user to ignore implicit triggers provided by the COD software.
C32 radBridgeCODNumAccess1.3.6.1.4.1.164.4.1.4.1.1.7Counter32read-onlyThe number of successful connections that have been established since the COD has been reset.
I32 radBridgeCODTotalConnecTime1.3.6.1.4.1.164.4.1.4.1.1.8Integer32read-onlyThe sum of all the connect time intervals since the COD was reset.
radBridgeCODTimeTriggerTable1.3.6.1.4.1.164.4.1.4.2not-accessibleThe table of COD parameters
radBridgeCODTimeTriggerEntry1.3.6.1.4.1.164.4.1.4.2.1not-accessibleEach radBridgeCODTimeTriggerEntry consists of the following parameters
I32 radBridgeCODTimeIfIndex1.3.6.1.4.1.164.4.1.4.2.1.1Integer32read-onlyThe interface to which this COD Time Trigger entry is applicable.
INT radBridgeCODDay1.3.6.1.4.1.164.4.1.4.2.1.2INTEGERread-onlyThe day of the week in which the dial up connection operates.
I32 radBridgeCODTimeTriggerNum1.3.6.1.4.1.164.4.1.4.2.1.3Integer32read-onlyEvery day of the week the user can configure 3 dial up connections.
STR radBridgeCODTimeTriggerFrom1.3.6.1.4.1.164.4.1.4.2.1.4DisplayStringread-writeTime to start Dial Up connection, in format hh:mm.
STR radBridgeCODTimeTriggerTo1.3.6.1.4.1.164.4.1.4.2.1.5DisplayStringread-writeTime to terminate Dial Up connection, in format HH:MM.
INT radBridgeCODTimeTriggerStatus1.3.6.1.4.1.164.4.1.4.2.1.6INTEGERread-writeThe status of a table entry.
radBridgeCODTraffic1.3.6.1.4.1.164.4.1.4.3
radBridgeCODTrafficTable1.3.6.1.4.1.164.4.1.4.3.1not-accessibleThe table of COD Traffic trigger
radBridgeCODTrafficEntry1.3.6.1.4.1.164.4.1.4.3.1.1not-accessibleEach radBridgeCODTrafficEntry consists of the following parameters.
INT radBridgeCODProtocolType1.3.6.1.4.1.164.4.1.4.3.1.1.1INTEGERread-onlyThe Protocol Type of the Traffic Table
INT radBridgeCODTrafficTriggerStatus1.3.6.1.4.1.164.4.1.4.3.1.1.2INTEGERread-writeCommand of Status of the Protocol Traffic Trigger
IP radBridgeCODRemoteIPAddr1.3.6.1.4.1.164.4.1.4.3.2IpAddressread-writeThis is the Remote IP Address
IP radBridgeCODIPMask1.3.6.1.4.1.164.4.1.4.3.3IpAddressread-writeThis is the Mask of the Remote IP Address
OCT radBridgeCODTrafficTriggerProtType1.3.6.1.4.1.164.4.1.4.3.4OCTET STRINGread-writeProtocol Type for the User Defined Protocol Traffic Trigger (3).
radBridgeCODCondTable1.3.6.1.4.1.164.4.1.4.4not-accessibleThe table of COD Condition parameters
radBridgeCODCondEntry1.3.6.1.4.1.164.4.1.4.4.1not-accessibleEach radBridgeCODCondEntry consists of the following parameters
I32 radBridgeCODCondIfIndex1.3.6.1.4.1.164.4.1.4.4.1.1Integer32read-onlyThe interface, this COD entry is applicable to.
INT radBridgeCODOriginateConnectCondition1.3.6.1.4.1.164.4.1.4.4.1.2INTEGERread-writeThis condition, allows the user to specify the condition under which the link is connected. The options are onPowerOn - On power on. whenAnyStationOnLan - When any station on lan. onTraffic - On traffic. The user can specify the condition/s for connection. The connection will be defined in CODSpecificOnTrafficConditionOID . onManualConnect - depends on radBridgeCODManualConnect OBJECT-TYPE (=connect).
INT radBridgeCODOriginateDisConnectCondition1.3.6.1.4.1.164.4.1.4.4.1.3INTEGERread-writeThis condition allows the user to specify the condition under which the link is disconnected. The options are: noStationOnLan - When there is no station on lan. Counts 15 minutes from the point the last frame from lan has been received. If no frame have been transmitted on lan by the end of this period, disconnect the connection. onTraffic - On traffic. The user can specify the condition/s for disconnection. The disconnection will be defined in CODSpecificOnTrafficConditionOID . onDelayFromConnectionOnRequest - On Delay From Connection On Request . The delay time period will be defined in CODOriginateDisConnectDelay . onManualDisConnect - depends on radBridgeCODManualConnect OBJECT-TYPE (=disconnect).
I32 radBridgeCODOriginateDisConnectDelay1.3.6.1.4.1.164.4.1.4.4.1.4Integer32read-writeDelay time in seconds.
INT radBridgeCODAnswerConnectCondition1.3.6.1.4.1.164.4.1.4.4.1.5INTEGERread-writeCODCondAnswerConnect allows the user to specify the condition under which the link is connected. The options are: onPowerOn - On power on. whenAnyStationOnLan - When any station on lan. onTraffic - On traffic. The user can specify the condition/s for connection. The connection will be defined in CODSpecificOnTrafficConditionOID . onManualConnect - depends on radBridgeCODManualConnect OBJECT-TYPE .
OID radBridgeCODSpecificOnTrafficOIDCondition1.3.6.1.4.1.164.4.1.4.4.1.6OBJECT IDENTIFIERread-onlyA reference to a specific entry in the radBridgeMaskTable, which describes the particular COD condition . If Connect or Disconnect Conditions are not onTraffic, its value should be set to the OBJECT IDENTIFIER { 0 0 }.
I32 radBridgeCODDisConnectMinimunFramesNumber1.3.6.1.4.1.164.4.1.4.4.1.7Integer32read-writeFrames rate.
radBridgeIPX1.3.6.1.4.1.164.4.1.5
radBridgeIPXdriver1.3.6.1.4.1.164.4.1.5.1
INT radBridgeIPXForwarding1.3.6.1.4.1.164.4.1.5.1.1INTEGERread-writeThe indication of whether this entity is acting as an IPX gateway in respect to the forwarding of datagrams received by, but not addressed to, this entity. IPX gateways forward datagrams. IPX hosts do not. Note that changing this parameter requiers RESET of the router.
radBridgeIPXRip1.3.6.1.4.1.164.4.1.5.2
C32 radBridgeIPXRipOutPackets1.3.6.1.4.1.164.4.1.5.2.1Counter32read-onlyThe total number of packets transmitted by RIP.
C32 radBridgeIPXRipInPackets1.3.6.1.4.1.164.4.1.5.2.2Counter32read-onlyThe total number of packets received by RIP. This will include any packets that are subsequently discarded.
C32 radBridgeIPXRipInDiscards1.3.6.1.4.1.164.4.1.5.2.3Counter32read-onlyThe number of received packets discarded by RIP.
I32 radBridgeIPXRipTblNoOfEntries1.3.6.1.4.1.164.4.1.5.2.4Integer32read-onlyThe max number of entries that exist in the RIP routing table.
I32 radBridgeIPXRipTblBcastTrigUpdateInterval1.3.6.1.4.1.164.4.1.5.2.5Integer32read-writeThe default time interval (in seconds)between triggered RIP updates on a broadcast type interface. A triggered update occurs when a change is detected in the routing database. This time interval delays the broadcasting of these updates so that changes on the network will not result in a lot of triggered updates.
radBridgeIPXRipTable1.3.6.1.4.1.164.4.1.5.2.6not-accessibleThe routing table used by RIP to calculate routes to remote desination networks.
radBridgeIPXRipTableEntry1.3.6.1.4.1.164.4.1.5.2.6.1not-accessibleThe routing information for one of this entity's destination networks.
OCT radBridgeIPXRipDestNetwork1.3.6.1.4.1.164.4.1.5.2.6.1.1OCTET STRINGread-onlyThe destination network address to which this entry's routing information pertains.
INT radBridgeIPXRipPolicy1.3.6.1.4.1.164.4.1.5.2.6.1.2INTEGERread-onlyA value specifying the precidence of the route. A value of zero means that the route is the best route, a value of one means that the route is the second best route and so on.
OCT radBridgeIPXRipForwardingRouter1.3.6.1.4.1.164.4.1.5.2.6.1.3OCTET STRINGread-writeThe IPX node address of the next hop (router) for the entry's associated destination network.
I32 radBridgeIPXRipNIC1.3.6.1.4.1.164.4.1.5.2.6.1.4Integer32read-writeAn interface identifier specifying what IPX interface the next hop can be found on.
I32 radBridgeIPXRipTickMetric1.3.6.1.4.1.164.4.1.5.2.6.1.5Integer32read-writeThe metric, in terms of transit time, associated with the route given by the entry. This time is in terms of 1/18ths of a second.
I32 radBridgeIPXRipHopMetric1.3.6.1.4.1.164.4.1.5.2.6.1.6Integer32read-writeThe metric, in terms of distance , associated with the route given by the entry.
TIK radBridgeIPXRipAgingTime1.3.6.1.4.1.164.4.1.5.2.6.1.7TimeTicksread-onlyThe last time that the entry was updated. The time will be provided in terms of the MIB-I object sysUpTime.
INT radBridgeIPXRipValueStatus1.3.6.1.4.1.164.4.1.5.2.6.1.8INTEGERread-writeThe entry status value; whether the entry is permanent (added statically), reachable or unreachable. In the latter two cases it would be added by RIP. A semiDynamic entry is an entry enterd manualy by the user and can be updated by the router.
INT radBridgeIPXRipForwardType1.3.6.1.4.1.164.4.1.5.2.6.1.9INTEGERread-writeThe type of route. Note that local(2) refers to a route for which the next hop is the final destination; remote(3) refers to a route for which the next hop is not the final destination.
radBridgeIPXRipInfTable1.3.6.1.4.1.164.4.1.5.2.7not-accessibleThe RIP interface table.
radBridgeIPXRipInfEntry1.3.6.1.4.1.164.4.1.5.2.7.1not-accessibleEach entry corresponds to one ifindex.
I32 radBridgeIPXRipInfIfIndex1.3.6.1.4.1.164.4.1.5.2.7.1.1Integer32read-onlyThis value of Ifindex is same as radBridgeIPXIfIndex in the IPX Interface Table.
I32 radBridgeIPXRipInfBcastUpdate1.3.6.1.4.1.164.4.1.5.2.7.1.2Integer32read-writeThe RIP periodic update interval, in seconds. Zero value corresponds to infinite interval.
I32 radBridgeIPXRipInfAgeMultiplier1.3.6.1.4.1.164.4.1.5.2.7.1.3Integer32read-writeThe holding multiplier for information received in RIP periodic updates. Zero value corresponds to infinite aging time.
radBridgeIPXSap1.3.6.1.4.1.164.4.1.5.3
C32 radBridgeIPXSapOutPackets1.3.6.1.4.1.164.4.1.5.3.1Counter32read-onlyThe total number of packets transmitted by SAP.
C32 radBridgeIPXSapInPackets1.3.6.1.4.1.164.4.1.5.3.2Counter32read-onlyThe total number of packets received by SAP. This will include any packets that are subsequently discarded.
C32 radBridgeIPXSapInDiscards1.3.6.1.4.1.164.4.1.5.3.3Counter32read-onlyThe number of received packets discarded by SAP.
I32 radBridgeIPXSapTblNoOfEntries1.3.6.1.4.1.164.4.1.5.3.4Integer32read-onlyThe max number of entries that exist in the SAP Server Information table.
I32 radBridgeIPXSapTblBcastTrigUpdateInterval1.3.6.1.4.1.164.4.1.5.3.5Integer32read-writeThe default time interval (in seconds) between triggered SAP updates on a broadcast style interface. A triggered update occurs when a change is detected in the service database. This time interval delays the transmission of these updates so that changes on the network will not result in a lot of triggered updates.
radBridgeIPXSapTable1.3.6.1.4.1.164.4.1.5.3.6not-accessibleThe Server Information table is used by SAP to store information of services which are available on the internetwork.
radBridgeIPXSapTableEntry1.3.6.1.4.1.164.4.1.5.3.6.1not-accessibleThe server information for one of this entity's server entries.
I32 radBridgeIPXSapServerType1.3.6.1.4.1.164.4.1.5.3.6.1.1Integer32read-onlyThe type of the server for which this entry pertains.
STR radBridgeIPXSapName1.3.6.1.4.1.164.4.1.5.3.6.1.2DisplayStringread-onlyThe name of the server for which this entry pertains.
OCT radBridgeIPXSapNetwork1.3.6.1.4.1.164.4.1.5.3.6.1.3OCTET STRINGread-writeThe IPX network address of the host on which this server exists.
OCT radBridgeIPXSapNode1.3.6.1.4.1.164.4.1.5.3.6.1.4OCTET STRINGread-writeThe IPX node address of the host on which this server exists.
I32 radBridgeIPXSapSocket1.3.6.1.4.1.164.4.1.5.3.6.1.5Integer32read-writeThe IPX socket number that is being used by the server to which this entry pertains.
I32 radBridgeIPXSapHopsToServer1.3.6.1.4.1.164.4.1.5.3.6.1.6Integer32read-writeThe number of hops to the entity on which this server exists.
I32 radBridgeIPXSapNIC1.3.6.1.4.1.164.4.1.5.3.6.1.7Integer32read-writeAn Network Interface Card identifier specifying what IPX interface the next hop can be found on.
TIK radBridgeIPXSapAgingTime1.3.6.1.4.1.164.4.1.5.3.6.1.8TimeTicksread-onlyThe last time that the entry was updated. The time will be provided in terms of the MIB-I object sysUpTime.
INT radBridgeIPXSapStatus1.3.6.1.4.1.164.4.1.5.3.6.1.9INTEGERread-writeThe status of the entry.
radBridgeIPXSapInfTable1.3.6.1.4.1.164.4.1.5.3.7not-accessibleThe Sap interface table.
radBridgeIPXSapInfEntry1.3.6.1.4.1.164.4.1.5.3.7.1not-accessibleEach entry corresponds to one ifindex.
I32 radBridgeIPXSapInfIfIndex1.3.6.1.4.1.164.4.1.5.3.7.1.1Integer32read-onlyThis value of Ifindex is same as radBridgeIPXIfIndex in the IPX Interface Table.
I32 radBridgeIPXSapInfBcastUpdate1.3.6.1.4.1.164.4.1.5.3.7.1.2Integer32read-writeThe SAP periodic update interval, in seconds. Zero value corresponds to infinite interval.
I32 radBridgeIPXSapInfAgeMultiplier1.3.6.1.4.1.164.4.1.5.3.7.1.3Integer32read-writeThe holding multiplier for information received in SAP periodic updates. Zero value corresponds to infinite aging time.
newMasking1.3.6.1.4.1.164.4.1.6
I32 maskingMaxEntries1.3.6.1.4.1.164.4.1.6.1Integer32read-onlyThe maximum number of entries in the masking table.
I32 maskingCurrentEntries1.3.6.1.4.1.164.4.1.6.2Integer32read-onlyThe number of entries in the mask table.
maskingTable1.3.6.1.4.1.164.4.1.6.3not-accessibleThis is the new masking scheme. Mask tables enable definition of forwarding restrictions and control of message flow in the internetwork. Each entry in this table defines a mask statement and an action defined by maskingOperation.
maskingEntry1.3.6.1.4.1.164.4.1.6.3.1not-accessibleDefines the contents of each line in the mask table.
INT maskingType1.3.6.1.4.1.164.4.1.6.3.1.1INTEGERread-onlyDefines the type of mask entry.
I32 maskingIfIndex1.3.6.1.4.1.164.4.1.6.3.1.2Integer32read-onlySpecifies the ifIndex of the interface to which the mask is applied.
I32 maskingIndex1.3.6.1.4.1.164.4.1.6.3.1.3Integer32read-onlyAn index to the masking table. This number should not be greater than maskingMaxEntries
INT maskingProtocolType1.3.6.1.4.1.164.4.1.6.3.1.4INTEGERread-writeThe base protocol for masking. IPX, IP, others.
OID maskingSmartMaskOID1.3.6.1.4.1.164.4.1.6.3.1.5OBJECT IDENTIFIERread-onlyA reference to a specific Smart mask table (old radBridgeMaskTable) which enables a more specific mask type. If this information is not available, its value should be set to the OBJECT IDENTIFIER { 0 0 }.
INT maskingFrameType1.3.6.1.4.1.164.4.1.6.3.1.6INTEGERread-writeEnables the user to decide about frame type * all frame * just broadcast * just multicast.
INT maskingFrameTypeCondition1.3.6.1.4.1.164.4.1.6.3.1.7INTEGERread-writeSpecifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingFrameType the packet contains data that matches the content of maskingFrameType. fa lse - Condition is valid if at the position specified by maskingFrameType the packet contains data that does not match the content of maskingFrameType.
ADR maskingSourceAddress1.3.6.1.4.1.164.4.1.6.3.1.8GenAddressread-writeThe source address is according to the maskingMacOrNet and maskingProtocolType variables. In case of 'MAC' enter 6 bytes (48 bit) of source address. In case of 'NET' if the maskingProtocolType is IP, this is the IP address if the maskingProtocolType is IPX, this is the IPX address (nnnnmmmmmmss) nnnn - IPX net address mmmmmm - Node address (Mac) ss - IPX socket In case of 'Apple' nn - net address (4 nibbles) ss - socket (4 nibbles).
ADR maskingSourceActiveBits1.3.6.1.4.1.164.4.1.6.3.1.9GenAddressread-writeSpecifies the positions of the wild card characters (*) in the maskingSourceAddress field. Only the 1's bit will be taken in considerations.
INT maskingSourceMacOrNet1.3.6.1.4.1.164.4.1.6.3.1.10INTEGERread-writeThe variable maskingSourceAddress and maskingSourceActiveBits will be treated as MAC, or NET address. - If maskingProtocolType = 'all', 'sna', 'netbios', dec or 'unknown', the maskingSourceMacOrNet can be macAddress only! - If maskingProtocolType = 'ip' the maskingSourceMacOrNet can be macAddress or netAddress or appleAddress. - If maskingProtocolType = 'ipx', the maskingSourceMacOrNet can be either macAddress or netAddress. - If maskingProtocolType = 'apple', the maskingSourceMacOrNet can be either macAddress or appleAddress.
INT maskingSourceCondition1.3.6.1.4.1.164.4.1.6.3.1.11INTEGERread-writeSpecifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingSourceAddress (in conjunction with maskingSourceActiveBits) the packet contains data that matches the content of maskingSourceAddress. false - Condition is valid if at the position specified by maskingSourceAddress (in conjunction with maskingSourceActiveBits) the packet contains data that does not match the content of maskingSourceAddress.
ADR maskingDestAddress1.3.6.1.4.1.164.4.1.6.3.1.12GenAddressread-writeIf maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. The destination address is according to the maskingMacOrNet and maskingProtocolType variables. In case of 'MAC' enter 6 bytes (48 bit) of source address. In case of 'NET' if the maskingProtocolType is IP, this is the IP address if the maskingProtocolType is IPX, this is the IPX address (nnnnmmmmmmss) nnnn - IPX net address mmmmmm - Node address (Mac) ss - IPX socket. In case of 'Apple' nn - net address (4 nibbles) ss - socket (4 nibbles). The IPX socket entered here has priority over the value of maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx, unless the entered IPX socket is don't care.
ADR maskingDestActiveBits1.3.6.1.4.1.164.4.1.6.3.1.13GenAddressread-writeIf maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. Specifies the positions of the wild card characters (*) in the maskingDestAddress field. Only the 1's bit will be taken in considerations.
INT maskingDestMacOrNet1.3.6.1.4.1.164.4.1.6.3.1.14INTEGERread-writeIf maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. - If maskingProtocolType = 'all', 'sna', 'netbios', dec or 'unknown', the maskingDestMacOrNet can be macAddress only! - If maskingProtocolType = 'ip' the maskingDestMacOrNet can be macAddress or netAddress or appleAddress. - If maskingProtocolType = 'ipx', the maskingDestMacOrNet can be either macAddress or netAddress. - If maskingProtocolType = 'apple', the maskingDestMacOrNet can be either macAddress or appleAddress. The variable maskingDestAddress and maskingDestActiveBits will be treated as MAC, or NET address.
INT maskingDestCondition1.3.6.1.4.1.164.4.1.6.3.1.15INTEGERread-writeIf maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingDestAddress (in conjunction with maskingDestActiveBits) the packet contains data that matches the content of maskingDestAddress. false - Condition is valid if at the position specified by maskingDestAddress (in conjunction with maskingDestActiveBits) the packet contains data that does not match the content of maskingDestAddress.
INT maskingLowLevelProt1.3.6.1.4.1.164.4.1.6.3.1.16INTEGERread-writeThis field is set in conjunction with the maskingProtocolType variable. This variable specifies the low level protocol. The IPX socket entered in maskingDestAddress has priority over the value of maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx, unless the entered IPX socket is don't care.
INT maskingLowLevelProtCondition1.3.6.1.4.1.164.4.1.6.3.1.17INTEGERread-writeSpecifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingLowLevelProt the packet contains data that matches the content of maskingLowLevelProt. false - Condition is valid if at the position specified by maskingLowLevelProt the packet contains data that does not match the content of maskingLowLevelProt.
I32 maskingHighLevelProt1.3.6.1.4.1.164.4.1.6.3.1.18Integer32read-writeThis field is set in connection to the maskingProtocolType variable. This variable specifies the high level protocols (application). As for today it supports just IP protocol stack. The object's value is a sum of the following instances values (selected by user): none (0), -- don't care ftp (1), ftpC (2), telnet (4), smtp (8), tftp (16), snmp (32), snmpTrap (64), ipRip (128), www (256), email (512), dns (1024), For Apple Protocol only: rtmp (2048), nbp (4096), atp (8192), aep (16384), zip (32768), adsp (65536), pap (131072), asp (262144) Example: if ftp(1), snmp(32) and snmpTrap(64) instances were selected, the value should be 97 (=1+32+64).
INT maskingHighLevelProtCondition1.3.6.1.4.1.164.4.1.6.3.1.19INTEGERread-writeSpecifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingHighLevelProt the packet contains data that matches the content of maskingHighLevelProt. false - Condition is valid if at the position specified by maskingHighLevelProt the packet contains data that does not match the content of maskingHighLevelProt.
I32 maskingPortNum1.3.6.1.4.1.164.4.1.6.3.1.20Integer32read-writeThe port number is the same as in high level protocol. It specifies the dest. port in IP case or the dest. socket in case of IPX & apple protocols. IP - This object is applicable only if none (0) value was selected in maskingHighLevelProt. IPX - This object is applicable only if the socket entered in maskingDestAddress is 'don't care'(00) AND maskingLowLevelProt is NOT ipxRip or ipxSap. Apple - This option is applicable only if the socket entered in maskingDestAddress is 'don't care'(00).
INT maskingPortNumCondition1.3.6.1.4.1.164.4.1.6.3.1.21INTEGERread-writeSpecifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingPortNum the packet contains data that matches the content of maskingPortNum. false - Condition is valid if at the position specified by maskingPortNum the packet contains data that does not match the content of maskingPortNum. This object is applicable only when maskingPortNum is applicable.
INT maskingOperation1.3.6.1.4.1.164.4.1.6.3.1.22INTEGERread-writeThe type of action to be taken if the frame meets the conditions of the mask. noOp = disabled (mask remains on list, but is not active) delete = mask is removed from the list. smartMask = the operation and destination of the mask will be determined by the objects of the Smart Table (old masking table: radBridgeMaskTable). If maskingType is codConnect, the 'block' value is NOT allowed. If maskingType is codDisconnect, the 'forward' value is NOT allowed.
I32 maskingSrcPortNum1.3.6.1.4.1.164.4.1.6.3.1.23Integer32read-writeThe source port number. For IP: No Condition. For IPX: This object is applicable only if the socket entered in maskingSourceAddress is don't care (00) and maskingLowLevelProt is NOT ipxRip or ipxSap. For Apple:This object is applicable only if the socket entered in maskingSourceAddress is don't care (00).
INT maskingSrcPortNumCondition1.3.6.1.4.1.164.4.1.6.3.1.24INTEGERread-writeThe same as 'maskingPortNumCondition'. Relates to source port.
radBridgePerformance1.3.6.1.4.1.164.4.1.7
radBridgeCurrentTable1.3.6.1.4.1.164.4.1.7.1not-accessibleThe RAD Bridge Current table.
radBridgeCurrentEntry1.3.6.1.4.1.164.4.1.7.1.1not-accessibleAn entry in the RAD Bridge Current table.
I32 radBridgeCurrentIndex1.3.6.1.4.1.164.4.1.7.1.1.1Integer32read-onlyThe index of the Bridge interface or Bridge Port. It may be ifIndex.
G32 radBridgeCurrentIngressFilteringDiscardedFrames1.3.6.1.4.1.164.4.1.7.1.1.2Gauge32read-onlyThe counter associated with the number of Discarded Frames upon Ingress Filtering, encountered by a Bridge interface in the current 15 minute interval.
G32 radBridgeCurrentFrameTypeDiscardedFrames1.3.6.1.4.1.164.4.1.7.1.1.3Gauge32read-onlyThe counter associated with the number of Discarded Frames upon Frame Type and Tagging Mismatch, encountered by a Bridge interface in the current 15 minute interval.
G32 radBridgeCurrentRxCorrectFrames1.3.6.1.4.1.164.4.1.7.1.1.4Gauge32read-onlyThe counter associated with the number of Received Correct Frames, encountered by a Bridge Port in the current 15 minute interval.
G32 radBridgeCurrentRxCorrectBytes1.3.6.1.4.1.164.4.1.7.1.1.5Gauge32read-onlyThe counter associated with the number of Received Correct Bytes, encountered by a Bridge Port in the current 15 minute interval.
G32 radBridgeCurrentRxCorrectBytesHCOverflow1.3.6.1.4.1.164.4.1.7.1.1.6Gauge32read-onlyThe counter associated with the number of times the associated radBridgeCurrentRxCorrectBytes counter has overflowed.
G32 radBridgeCurrentRxBcastFrames1.3.6.1.4.1.164.4.1.7.1.1.7Gauge32read-onlyThe counter associated with the number of Received Broadcast Frames, encountered by a Bridge Port in the current 15 minute interval.
G32 radBridgeCurrentRxMcastFrames1.3.6.1.4.1.164.4.1.7.1.1.8Gauge32read-onlyThe counter associated with the number of Received Multicast Frames, encountered by a Bridge Port in the current 15 minute interval.
G32 radBridgeCurrentTxCorrectFrames1.3.6.1.4.1.164.4.1.7.1.1.9Gauge32read-onlyThe counter associated with the number of Transmitted Correct Frames, encountered by a Bridge Port in the current 15 minute interval.
G32 radBridgeCurrentTxCorrectBytes1.3.6.1.4.1.164.4.1.7.1.1.10Gauge32read-onlyThe counter associated with the number of Transmitted Correct Bytes, encountered by a Bridge Port in the current 15 minute interval.
G32 radBridgeCurrentTxCorrectBytesHCOverflow1.3.6.1.4.1.164.4.1.7.1.1.11Gauge32read-onlyThe counter associated with the number of times the associated radBridgeCurrentTxCorrectBytes counter has overflowed.
G32 radBridgeCurrentTxBcastFrames1.3.6.1.4.1.164.4.1.7.1.1.12Gauge32read-onlyThe counter associated with the number of Transmitted Broadcast Frames, encountered by a Bridge Port in the current 15 minute interval.
G32 radBridgeCurrentTxMcastFrames1.3.6.1.4.1.164.4.1.7.1.1.13Gauge32read-onlyThe counter associated with the number of Transmitted Multicast Frames, encountered by a Bridge Port in the current 15 minute interval.
G32 radBridgeCurrentTxDropFrames1.3.6.1.4.1.164.4.1.7.1.1.14Gauge32read-onlyThe counter associated with the number of Transmitted Dropped Frames, encountered by a Bridge Port in the current 15 minute interval.
radBridgeIntervalTable1.3.6.1.4.1.164.4.1.7.2not-accessibleThe RAD Bridge Interval table.
radBridgeIntervalEntry1.3.6.1.4.1.164.4.1.7.2.1not-accessibleAn entry in the RAD Bridge Interval table.
I32 radBridgeIntervalIndex1.3.6.1.4.1.164.4.1.7.2.1.1Integer32read-onlyThe index of the bridge interface or Bridge Port. It may be ifIndex.
I32 radBridgeIntervalNumber1.3.6.1.4.1.164.4.1.7.2.1.2Integer32read-onlyA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist).
G32 radBridgeIntervalIngressFilteringDiscardedFrames1.3.6.1.4.1.164.4.1.7.2.1.3Gauge32read-onlyThe counter associated with the number of Discarded Frames upon Ingress Filtering, encountered by a Bridge interface in one of the previous 96, individual 15 minute, intervals.
G32 radBridgeIntervalFrameTypeDiscardedFrames1.3.6.1.4.1.164.4.1.7.2.1.4Gauge32read-onlyThe counter associated with the number of Discarded Frames upon Frame Type and Tagging Mismatch, encountered by a Bridge interface in one of the previous 96, individual 15 minute, intervals.
G32 radBridgeIntervalRxCorrectFrames1.3.6.1.4.1.164.4.1.7.2.1.5Gauge32read-onlyThe counter associated with the number of Received Correct Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
G32 radBridgeIntervalRxCorrectBytes1.3.6.1.4.1.164.4.1.7.2.1.6Gauge32read-onlyThe counter associated with the number of Received Correct Bytes, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
G32 radBridgeIntervalRxCorrectBytesHCOverflow1.3.6.1.4.1.164.4.1.7.2.1.7Gauge32read-onlyThe counter associated with the number of times the associated radBridgeIntervalRxCorrectBytes counter has overflowed.
G32 radBridgeIntervalRxBcastFrames1.3.6.1.4.1.164.4.1.7.2.1.8Gauge32read-onlyThe counter associated with the number of Received Broadcast Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
G32 radBridgeIntervalRxMcastFrames1.3.6.1.4.1.164.4.1.7.2.1.9Gauge32read-onlyThe counter associated with the number of Received Multicast Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
G32 radBridgeIntervalTxCorrectFrames1.3.6.1.4.1.164.4.1.7.2.1.10Gauge32read-onlyThe counter associated with the number of Transmitted Correct Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
G32 radBridgeIntervalTxCorrectBytes1.3.6.1.4.1.164.4.1.7.2.1.11Gauge32read-onlyThe counter associated with the number of Transmitted Correct Bytes, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
G32 radBridgeIntervalTxCorrectBytesHCOverflow1.3.6.1.4.1.164.4.1.7.2.1.12Gauge32read-onlyThe counter associated with the number of times the associated radBridgeIntervalTxCorrectBytes counter has overflowed.
G32 radBridgeIntervalTxBcastFrames1.3.6.1.4.1.164.4.1.7.2.1.13Gauge32read-onlyThe counter associated with the number of Transmitted Broadcast Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
G32 radBridgeIntervalTxMcastFrames1.3.6.1.4.1.164.4.1.7.2.1.14Gauge32read-onlyThe counter associated with the number of Transmitted Multicast Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
G32 radBridgeIntervalTxDropFrames1.3.6.1.4.1.164.4.1.7.2.1.15Gauge32read-onlyThe counter associated with the number of Transmitted Dropped Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
radBridgePortBaseVlan1.3.6.1.4.1.164.4.1.8
radBridgePortBaseVlanTable1.3.6.1.4.1.164.4.1.8.1not-accessibleA table containing static configuration information for each VLAN configured into the device by management. All entries are permanent and will be restored after the device is reset.
radBridgePortBaseVlanEntry1.3.6.1.4.1.164.4.1.8.1.1not-accessibleStatic information for a VLAN configured into the device by (local or network) management.
I32 radBridgePortBaseVlanCnfgIdx1.3.6.1.4.1.164.4.1.8.1.1.1Integer32not-accessibleThis object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1.
I32 radBridgePortBaseVlanIdx1.3.6.1.4.1.164.4.1.8.1.1.2Integer32not-accessibleIndex of the port based VLAN.
STR radBridgePortBaseVlanName1.3.6.1.4.1.164.4.1.8.1.1.3SnmpAdminStringread-createAn administratively assigned string, which may be used to identify the the port based VLAN.
POR radBridgePortBaseVlanEgressPorts1.3.6.1.4.1.164.4.1.8.1.1.4PortListread-createThe set of ports which are permanently assigned to the egress list for this port based VLAN by management. The default value of this object is a string of zeros.
POR radBridgePortBaseVlanVirtualGroups1.3.6.1.4.1.164.4.1.8.1.1.5PortListread-createThe set of Virtual Groups which are permanently assigned to this port based VLAN by management. (read Virtual Group instead of port in PortList Textual Convention) The default value of this object is a string of zeros.
ROW radBridgePortBaseVlanRowStatus1.3.6.1.4.1.164.4.1.8.1.1.6RowStatusread-createThis object enable user to create/delete entries in this table.
INT radBridgePortBaseVlanMng1.3.6.1.4.1.164.4.1.8.1.1.7INTEGERread-createThis object allows user to enable/disable management traffic on this VLAN. disable - only non-management data is allowed. enable - mixture of management traffic 0with other types of data is allowed.
radBridgePortVlanMemberTable1.3.6.1.4.1.164.4.1.8.2not-accessibleThe Bridge Ports-VLAN Membership table. This table enables the user to assign: - Several VLANs to a Port. - Several Ports to a VLAN.
radBridgePortVlanMemberEntry1.3.6.1.4.1.164.4.1.8.2.1not-accessibleAn entry in the Bridge Ports-VLANs Memebership table.
I32 radBridgePortVlanMemberBridgeIdx1.3.6.1.4.1.164.4.1.8.2.1.1Integer32read-onlyThis object indicates the Bridge Index.
I32 radBridgePortVlanMemberPortIdx1.3.6.1.4.1.164.4.1.8.2.1.2Integer32read-onlyThis object indicates the Bridge's Port Index. For some cases, it can be used as the Port ofIndex.
I32 radBridgePortVlanMemberVlanId1.3.6.1.4.1.164.4.1.8.2.1.3Integer32read-onlyThis object indicates the VLAN ID.
ROW radBridgePortVlanMemberRowStatus1.3.6.1.4.1.164.4.1.8.2.1.4RowStatusread-createThis object enables the user to create/delete entries in this table.
radBridgeGenCnfg1.3.6.1.4.1.164.4.1.9
radBridgeGenFlowTable1.3.6.1.4.1.164.4.1.9.1not-accessibleA table containing static configuration information for Bridge configured into the device by (local or network) management. All entries are permanent and will be restored after the device is reset.
radBridgeGenFlowEntry1.3.6.1.4.1.164.4.1.9.1.1not-accessibleStatic information for a Bridge configured into the device by management.
I32 radBridgeGenFlowCnfgIdx1.3.6.1.4.1.164.4.1.9.1.1.1Integer32not-accessibleThis object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1. This object can be used to carry additional indexing (e.g port index) when needed.
I32 radBridgeGenFlowIdx1.3.6.1.4.1.164.4.1.9.1.1.2Integer32not-accessibleFor Agent having more than one bridge, this index may be used as bridge index
ROW radBridgeGenFlowRowStatus1.3.6.1.4.1.164.4.1.9.1.1.3RowStatusread-createThis object enable user to create/delete entries in this table.
I32 radBridgeGenFlowFloodOrBcastMaxRate1.3.6.1.4.1.164.4.1.9.1.1.4Integer32read-createThis object controls maximum Flooding or Broadcast Rate: Max number of multicast along with unknown or flooded unicast frames allowed to enter any port. The number can be presented either as percentage of bandwidth, or bandwidth in Kbps. Once the limit is exceeded, any multicast or flooded frame entering from the port is discarded For RIC-155, and FCD-155 valid values are 3% , 6%, 12% and 100% = No Limit
INT radBridgeGenFlowQosMode1.3.6.1.4.1.164.4.1.9.1.1.5INTEGERread-createThis object controls Quality of Service mode. User may select which field(s) (in case of fields - which one has precedence) will affect prioritization of data between egress queues.
INT radBridgeGenFlowSchedulingMode1.3.6.1.4.1.164.4.1.9.1.1.6INTEGERread-createThis object controls which scheduling mode is used: Weighted Fair Queuing (WFQ) scheme, Strict Priority (SP) or ATM CoS
INT radBridgeGenFlowBasicClassification1.3.6.1.4.1.164.4.1.9.1.1.7INTEGERread-createThis object defines whether Classification based on Port should be taken into account (either as default, or in addition to other classifications).
I32 radBridgeGenFlowMulticastTrafficClass1.3.6.1.4.1.164.4.1.9.1.1.8Integer32read-createThe Traffic Class the received Multicast frame is mapped to.
I32 radBridgeGenFlowBroadcastTrafficClass1.3.6.1.4.1.164.4.1.9.1.1.9Integer32read-createThe Traffic Class the received Broadcast frame is mapped to.
I32 radBridgeGenFlowUnkownUnicastTrafficClass1.3.6.1.4.1.164.4.1.9.1.1.10Integer32read-createThe Traffic Class the received Unkonwn Unicast frame is mapped to.
radBridgeDot1qVlanStaticTable1.3.6.1.4.1.164.4.1.9.2not-accessibleA table containing static configuration information for each VLAN configured into the device by (local or network) management. All entries are permanent and will be restored after the device is reset.
radBridgeDot1qVlanStaticEntry1.3.6.1.4.1.164.4.1.9.2.1not-accessibleStatic information for a VLAN configured into the device by (local or network) management.
POR radBridgeDot1qVlanTaggedPorts1.3.6.1.4.1.164.4.1.9.2.1.1PortListread-createThe set of ports which should transmit egress packets for this VLAN as tagged.
POR radBridgeDot1qVlanUnmodifiedPorts1.3.6.1.4.1.164.4.1.9.2.1.2PortListread-createThe set of ports which should transmit egress packets for this VLAN as unmodified.
INT radBridgeDot1qVlanSplitHorizon1.3.6.1.4.1.164.4.1.9.2.1.3INTEGERread-createWhen 'enable (3)', packets having this VLAN will not be switched back to other bridge ports which are members of this VLAN.
radDot1qPortVlanTable1.3.6.1.4.1.164.4.1.9.3not-accessibleA table containing control and status information for VLAN configuration per port.
radDot1qPortVlanEntry1.3.6.1.4.1.164.4.1.9.3.1not-accessibleInformation controlling VLAN configuration for a port. This is indexed by dot1dBasePort.
INT radDot1qPortStacking1.3.6.1.4.1.164.4.1.9.3.1.1INTEGERread-writeThis object indicates the port stacking operation: unmodify (2) = Do not add Tag. tag (3) = Add Tag to Untagged Frames. stack (4) = Add Tag to all Frames.
INT radDot1qPortCopyOriginVlanPriority1.3.6.1.4.1.164.4.1.9.3.1.2INTEGERread-writeThis object indicates whether use the original VLAN Priority of the frame, as the priority of the VLAN added by this port.
I32 radDot1qPortDefaultVlanPriority1.3.6.1.4.1.164.4.1.9.3.1.3Integer32read-writeDefault VLAN Frame priority of the VLAN added by this port.
INT radDot1qPortTagStripping1.3.6.1.4.1.164.4.1.9.3.1.4INTEGERread-writeThis object indicates whether remove a tag from the frame on this port, frame with double tag will remain with one tag and frame with one tag will remain untagged.
INT radDot1qPortEgressTagHandling1.3.6.1.4.1.164.4.1.9.3.1.5INTEGERread-writeThis object indicates how is the Egress VLAN Tag processed. It is mainly for use with Double Tagging.
INT radDot1qPortIngressTagHandling1.3.6.1.4.1.164.4.1.9.3.1.6INTEGERread-writeThis object indicates how is the Ingress VLAN Tag processed. It is mainly for use with Double Tagging.
INT radDot1qPortReplaceVlanPriority1.3.6.1.4.1.164.4.1.9.3.1.7INTEGERread-writeThis object indicates whether for each received tagged frame on this Bridge Port - VLAN Priority will be replaced by another Priority. no(2) = no repacement yes(3) = VLAN Priority will be replaced For Egate-100: When value is 'yes', the original Priority is replaced by the Default Priority.
U32 radDot1qPortVlanEthType1.3.6.1.4.1.164.4.1.9.3.1.8Unsigned32read-writeThis object indicates the Ethernet Type. For some devices, it is applicable only when radDot1qPortStacking = stack.
INT radDot1qPortVlanCnodeLevel1Agent1.3.6.1.4.1.164.4.1.9.3.1.9INTEGERread-writeSpecify if a Level 1 cNode agent is enabled or not for the bridge port.
radBridgeGenCfgTable1.3.6.1.4.1.164.4.1.9.4not-accessibleA table containing Bridge configuration parameters.
radBridgeGenCfgEntry1.3.6.1.4.1.164.4.1.9.4.1not-accessibleDescribes an entry in the radBridgeGenCfgTable.
I32 radBridgeGenCfgIdx1.3.6.1.4.1.164.4.1.9.4.1.1Integer32not-accessibleThis object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg. For Agents that support only one Configuration, this object will be constant=1.
I32 radBridgeGenCfgIdx21.3.6.1.4.1.164.4.1.9.4.1.2Integer32not-accessibleFor Agents having more than one bridge, this index may be used as bridge index
INT radBridgeGenCfgBridgeAction1.3.6.1.4.1.164.4.1.9.4.1.3INTEGERread-writeThis variable enables the operator to perform one of the specified actions on the tables maintained by the Bridge. After performing the action, Agent will automatically Set the value of this variable to noOp(255).
INT radBridgeAgingTimeSec1.3.6.1.4.1.164.4.1.9.4.1.4INTEGERread-writeThis variable duplicates scalar object dot1dTpAgingTimeThe of BRIDGE-MIB with configuration index and Bridge index. It defines the timeout period in seconds for aging out dynamically learned forwarding information. 802.1D-1990 recommends a default of 300 seconds.
U32 radBridgeMngVlanId1.3.6.1.4.1.164.4.1.9.4.1.5Unsigned32read-writeThis variable indicates the VLAN ID used for remote management traffic. 0 = Not Applicable.
U32 radBridgeLoopDetectVlanId1.3.6.1.4.1.164.4.1.9.4.1.6Unsigned32read-writeThis variable indicates the VLAN ID used for Loop Detection packets. Valid values: 1 - 4095: VLAN ID 0 - Means that the Loop Detection is Disabled.
INT radBridgeSplitHorizon1.3.6.1.4.1.164.4.1.9.4.1.7INTEGERread-writeThis object configure 'split horizon' switching between bridge Ports. - disable - normal (VLAN aware) bridge behavior. - enable - all packets, regardless their VLAN, coming from user side are blocked from being switched back to other user side bridge ports. - vlanBased - split horizon behavior is applicable only for specific VLANs, according to radBridgeDot1qVlanSplitHorizon.
U32 radBridgeEthType1.3.6.1.4.1.164.4.1.9.4.1.8Unsigned32read-writeValue of Ethertype field in Ethernet frame. This field indicates which protocol is being transported in an ethernet frame.
INT radBridgeAgingTime1.3.6.1.4.1.164.4.1.9.5INTEGERread-writeThis variable defines whether the Aging Time will be finite or infinite. When selecting the finite (3) value, the exact time will be determined by another variable of the standard MIB (ex. 1493.dot1dTpAgingTime). or by radBridgeAgingTime below.
INT radBridgeMngFlow1.3.6.1.4.1.164.4.1.9.6INTEGERread-writeThis variable defines whether the Management Flow is passed through the bridge (enable) or not (disable).
radBridgeStatus1.3.6.1.4.1.164.4.1.10
radBridgeInvBasePortTable1.3.6.1.4.1.164.4.1.10.1not-accessibleAn inversed table to dot1dBasePortTable from RFC1493 with reduced information. This table index is known to the NMS and this way the needed information can be received by just one Get command, instead of searching the entire dot1dBasePortTable (where it is an attribute).
radBridgeInvBasePortEntry1.3.6.1.4.1.164.4.1.10.1.1not-accessibleThe bridge port number for each bridge port interface index.
I32 radBridgeInvBasePortIfIndex1.3.6.1.4.1.164.4.1.10.1.1.1Integer32read-onlyThe value of the instance of the ifIndex object, defined in MIB-II, for the interface corresponding to this Bridge port.
I32 radBridgeInvBasePort1.3.6.1.4.1.164.4.1.10.1.1.2Integer32read-onlyThe Bridge port number.
radBridgeStp1.3.6.1.4.1.164.4.1.11
radBridgeStpCnfgTable1.3.6.1.4.1.164.4.1.11.1not-accessibleSTP Configuration table. STP=Spanning Tree Protocol. It includes STP configurable parameters that in BRIDGE-MIB are scalars, while we need them per card/bridge/interface and per different configurations.
radBridgeStpCnfgEntry1.3.6.1.4.1.164.4.1.11.1.1not-accessibleAn entry in the radBridgeStpCnfgTable.
I32 radBridgeStpCnfgIdx11.3.6.1.4.1.164.4.1.11.1.1.1Integer32not-accessibleThis object indicates the Index of the Agent Configuration the following objects refer to. For Agents that support more than one configuration: 255=Temporary Cnfg ; Set can be done only to this configuration. For Agents that support only one configuration, this object will be constant=1.
I32 radBridgeStpCnfgIdx21.3.6.1.4.1.164.4.1.11.1.1.2Integer32not-accessibleFor Agents having the table objects per Card/Bridge/Interface this will be the index of the Card/Bridge/Interface used.
TIM radBridgeStpCnfgForwardDelay1.3.6.1.4.1.164.4.1.11.1.1.3Timeoutread-writeThe value that the bridge of radBridgeStpCnfgIdx2 uses for Forward Delay when this bridge is acting as the root. Note that the range for this parameter is related to the value of radBridgeStpCnfgMaxAge (according to 802.1D-1990 for the similar scalars of BRIDGE-MIB). The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
TIM radBridgeStpCnfgMaxAge1.3.6.1.4.1.164.4.1.11.1.1.4Timeoutread-writeThe value that the bridge of radBridgeStpCnfgIdx2 uses for MaxAge when this bridge is acting as the root. Note that the range for this parameter is related to the value of radBridgeStpCnfgHelloTime (according to 802.1D-1990 for the similar scalars of BRIDGE-MIB). The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
TIM radBridgeStpCnfgHelloTime1.3.6.1.4.1.164.4.1.11.1.1.5Timeoutread-writeThe value that the bridge of radBridgeStpCnfgIdx2 uses for Hello Time when this bridge is acting as the root. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
I32 radBridgeStpCnfgPriority1.3.6.1.4.1.164.4.1.11.1.1.6Integer32read-writeThe value of the write-able portion of the Bridge ID, i.e., the first two octets of the (8 octet long) Bridge ID, per radBridgeStpCnfgIdx2 instance.
INT radBridgeStpCnfgStpVersion1.3.6.1.4.1.164.4.1.11.1.1.7INTEGERread-writeThis object determines the STP version used: stp - usual Spanning Tree Protocol. rstp - Rapid Spanning Tree Protocol.
radBridgeStpStatTable1.3.6.1.4.1.164.4.1.11.2not-accessibleSTP Status table. STP=Spanning Tree Protocol. It includes STP status parameters that in BRIDGE-MIB are scalars, while we need them per card/bridge/interface. For devices that have several configurations, this table is for Status of the Active configuration.
radBridgeStpStatEntry1.3.6.1.4.1.164.4.1.11.2.1not-accessibleAn entry in the radBridgeStpStatTable.
I32 radBridgeStpStatIdx1.3.6.1.4.1.164.4.1.11.2.1.1Integer32not-accessibleFor Agents having the table objects per Card/Bridge/Interface this will be the index of the Card/Bridge/Interface used.
TIM radBridgeStpStatForwardDelay1.3.6.1.4.1.164.4.1.11.2.1.2Timeoutread-onlyThis time value, measured in units of hundredths of a second, controls how fast a port changes its spanning state when moving towards the Forwarding state. The value determines how long the port stays in each of the Listening and Learning states, which precede the Forwarding state. This value is also used, when a topology change has been detected and is underway, to age all dynamic entries in the Forwarding Database. [Note that this value is the one that this bridge is currently using, in contrast to radBridgeStpCnfgForwardDelay which is the value that this bridge would start using if/when this bridge were to become the root.]
TIM radBridgeStpStatMaxAge1.3.6.1.4.1.164.4.1.11.2.1.3Timeoutread-onlyThe maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is the actual value that this bridge is currently using.
TIM radBridgeStpStatHelloTime1.3.6.1.4.1.164.4.1.11.2.1.4Timeoutread-onlyThe amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become so, in units of hundredths of a second. This is the actual value that this bridge is currently using.
BRI radBridgeStpStatDesignatedRoot1.3.6.1.4.1.164.4.1.11.2.1.5BridgeIdread-onlyThe bridge identifier of the root of the spanning tree as determined by the Spanning Tree Protocol as executed by this node. This value is used as the Root Identifier parameter in all Configuration Bridge PDUs originated by this node.
I32 radBridgeStpStatRootCost1.3.6.1.4.1.164.4.1.11.2.1.6Integer32read-onlyThe cost of the path to the root as seen from this bridge.
INT radBridgeForwardingMode1.3.6.1.4.1.164.4.1.12INTEGERread-writeThis object determines the Bridge Forwarding Mode: transparent - Forward all frames received (not dependent on VLAN). filter - Filter frames received according to MAC Address. filterTagged = Filter frames received according to VLAN. transparentTagged = VLAN aware + Transparent.
radBridgePort1.3.6.1.4.1.164.4.1.13
radBridgePortCnfgTable1.3.6.1.4.1.164.4.1.13.1not-accessibleThe Bridge Port Configuration Table.
radBridgePortCnfgEntry1.3.6.1.4.1.164.4.1.13.1.1not-accessibleAn entry in the table.
I32 radBridgePortCnfgIdx1.3.6.1.4.1.164.4.1.13.1.1.1Integer32not-accessibleThe first index of the table. It can serve for Configuration index, Bridge index or other.
I32 radBridgePortCnfgPrtIdx1.3.6.1.4.1.164.4.1.13.1.1.2Integer32not-accessibleThis object indicates the Bridge Port index.
I32 radBridgePortCnfgMaxMacAddr1.3.6.1.4.1.164.4.1.13.1.1.3Integer32read-writeThis object indicates the maximum number of total MAC Addresses (static and learned) supported by this Bridge Port.
INT radBridgePortCnfgMngFlow1.3.6.1.4.1.164.4.1.13.1.1.4INTEGERread-writeThis object indicates whether this Bridge Port is dedicated for management flow.
INT radBridgePortCnfgMcastMode1.3.6.1.4.1.164.4.1.13.1.1.5INTEGERread-writeThis object indicates this Bridge Port's Multicast Mode: flooding (1) - flood multicast MAC addresses forwarding (2) - forward multicast MAC addresses to the subnet indicated.
I32 radBridgePortCnfgDefaultVpi1.3.6.1.4.1.164.4.1.13.1.1.6Integer32read-writeThis object indicates the VPI of this Bridge Port's Default VCL. An incoming frame with priority that is not assigned to any VCL will be transferred to the Default VCL.
I32 radBridgePortCnfgDefaultVci1.3.6.1.4.1.164.4.1.13.1.1.7Integer32read-writeThis object indicates the VCI of this Bridge Port's Default VCL. An incoming frame with priority that is not assigned to any VCL will be transferred to the Default VCL.
I32 radBridgePortCnfgStatVlanId1.3.6.1.4.1.164.4.1.13.1.1.8Integer32read-writeThis object indicates the selected VlanId of the bridge port on which statistics are being collected. 0=no Statistics collected for VLAN on this bridge port.
I32 radBridgePortCnfgIngressMtu1.3.6.1.4.1.164.4.1.13.1.1.9Integer32read-writeThe size of the largest packet which can be received on the interface, specified in octets.
I32 radBridgePortCnfgEgressMtu1.3.6.1.4.1.164.4.1.13.1.1.10Integer32read-writeThe size of the largest packet which can be sent on the interface, specified in octets.
INT radBridgePortCnfgDot1x1.3.6.1.4.1.164.4.1.13.1.1.11INTEGERread-writeThis feature is currently supported via the variable ethIfTable.ethDot1xEnable. Determnines if the Port-Based Network Access Protocol (IEEE-802.1x)is enabled for the bridge Port.
radConverters1.3.6.1.4.1.164.5
radGen1.3.6.1.4.1.164.6
systems1.3.6.1.4.1.164.6.1
systemsEvents1.3.6.1.4.1.164.6.1.0The events for RAD products.
NTF tftpStatusChangeTrap1.3.6.1.4.1.164.6.1.0.1This trap is sent whenever the status of tftp changed.
NTF agnStatusChangeTrap1.3.6.1.4.1.164.6.1.0.2This trap is sent whenever the state of the entity the agent is responsible for changed. TDM devices will send agnTestStatus variable to indicate the current test status.
NTF prtStatusChangeTrap1.3.6.1.4.1.164.6.1.0.3This trap is sent whenever the state of a port changed. Attached, will be parameter/s that indicate the new port status. The attached variables will be specified in the specifications of the products supporting this trap.
NTF swdlStatusResult1.3.6.1.4.1.164.6.1.0.4This notification is sent when Software Down Load is finished. The attached object indicates the File Name.
NTF intSwdlSlotFileMismatch1.3.6.1.4.1.164.6.1.0.5This notification is sent when the card in the chosen slot doesn't match the chosen file. The attached object indicates the File Name.
NTF agnCounterChange1.3.6.1.4.1.164.6.1.0.6This notification is sent when the value of a specific Counter is changed. Agent can send as attached object the updated Counter. For details about this Counter and attached object, see spec of the relevant application.
NTF prtClkSrcChangeTrap1.3.6.1.4.1.164.6.1.0.7This trap is sent upon any port clock change.
NTF moduleFailTrap1.3.6.1.4.1.164.6.1.0.8This trap is sent upon a module failure.
NTF moduleInitFailTrap1.3.6.1.4.1.164.6.1.0.9This trap is sent upon a module initialization failure.
NTF clkSrcChangeTrap1.3.6.1.4.1.164.6.1.0.10This trap is sent upon any change in Clock Source.
NTF agnUploadDataTrap1.3.6.1.4.1.164.6.1.0.11This trap is sent upon an upload data session termination. For more details see product specification.
NTF enrollmentTrap1.3.6.1.4.1.164.6.1.0.12This trap is a periodically trap, which sent to manager untill Agent get any response (Get or Set) from this manager.
NTF agnPowerFailureTrap1.3.6.1.4.1.164.6.1.0.13This trap is sent upon power failure. It is applicable for the following devices: 1. Devices having one PS unit, which sense the failure in advance, and still have time to send this trap before it goes off. 2. Devices having 2 PS units and send this trap in order to notify a failure in one of the units.
NTF agnFanFailureTrap1.3.6.1.4.1.164.6.1.0.14This trap is sent upon fan failure/recovery.
NTF agnSystemParameterChangeTrap1.3.6.1.4.1.164.6.1.0.15This trap is sent upon any change of the systemParameter value.
NTF agnConfigDBChecksumError1.3.6.1.4.1.164.6.1.0.16This trap indicates that the database currently stored in the non-volatile memory of the device is corrupted
NTF agnAlarmBufferOverflow1.3.6.1.4.1.164.6.1.0.17This trap indicates that the quantity of alarm messages which have been written in the alarm buffer, since the last clear command, exceeds predefined threshold. (Buffer size) The new alarms are overwriting the oldest alarms (the first alarms written in the buffer). For LA-110,threshold value is 200 alarms.
NTF agnAlarmBufferClear1.3.6.1.4.1.164.6.1.0.18This trap indicates that alarm buffer has been cleared.
NTF agnParametersValueChanged1.3.6.1.4.1.164.6.1.0.19This trap indicates that due to software upgrade, some of the parameters are assigned new values
NTF agnDriverSwMismatch1.3.6.1.4.1.164.6.1.0.20There is mismatch between the SW driver and the HW of the device uplink interface.
NTF agnActualLowRate1.3.6.1.4.1.164.6.1.0.21The main link is synchronized at a rate lower than expected.
NTF xModemFileTransferStatusTrap1.3.6.1.4.1.164.6.1.0.22This trap is sent in the following cases: - When an xModem File Transfer Session begins. In this case, the trapVal.1 string sent will be: 'Start'. - When an xModem File Transfer Session ends. In this case, the trapVal.1 string sent will be one of the following, according to the way the session ended : - 'End: OK' - 'End: Failed'
NTF agnStationClkFailureTrap1.3.6.1.4.1.164.6.1.0.23This trap is sent upon Station Clock failure.
NTF successfulLogin1.3.6.1.4.1.164.6.1.0.24This trap is sent when a user performed successful Login via Terminal/Telnet/Web. This trap is used when the device is located at End-User's premises while management is at Service Provider's premises.
NTF failedLogin1.3.6.1.4.1.164.6.1.0.25This trap is sent when a user tried to Login via Terminal/Telnet/Web and failed. This trap is used when the device is located at End-User's premises while management is at Service Provider's premises.
NTF modlChangeTrap1.3.6.1.4.1.164.6.1.0.26This trap is sent whenever a module is inserted or removed. The trap should include the new module type (e.g. modlParamType).
NTF licenseUpdateTrap1.3.6.1.4.1.164.6.1.0.27This trap is sent whenever a license is successfully downloaded or whenever a license's demo duration is expired.
NTF agnClkSrcStateChangeTrap1.3.6.1.4.1.164.6.1.0.28The trap is sent upon change in Recovery Clock State.
NTF agnSelfTestResultChangeTrap1.3.6.1.4.1.164.6.1.0.29The trap is sent upon each change in the result of a Self State operation.
NTF agnClkSrcFrequencyAlarmTrap1.3.6.1.4.1.164.6.1.0.31The trap is sent upon Recovered Clock Frequency alarm.
radSysTR1.3.6.1.4.1.164.6.1.1
radRADring1.3.6.1.4.1.164.6.1.1.1
radTMA1.3.6.1.4.1.164.6.1.1.2
radRingMonitor1.3.6.1.4.1.164.6.1.1.3
radSysFddi1.3.6.1.4.1.164.6.1.2
radFDX1001.3.6.1.4.1.164.6.1.2.1
radSysWan1.3.6.1.4.1.164.6.1.3
radSysWanEvents1.3.6.1.4.1.164.6.1.3.0The events for RAD Wan products.
NTF alarmStatusTrap1.3.6.1.4.1.164.6.1.3.0.5The trap is sent whenever there is a transition from a no alarm state to a state with at least one active alarm.
NTF systemTrap1.3.6.1.4.1.164.6.1.3.0.6This trap alerts of major problems in the device.
NTF alarmLOS1.3.6.1.4.1.164.6.1.3.0.7This trap indicates Loss Of Signal.
NTF alarmLOF1.3.6.1.4.1.164.6.1.3.0.8This trap indicates Loss Of Frame.
NTF channelOperStatusTrap1.3.6.1.4.1.164.6.1.3.0.9This trap is sent upon any change in one or more channels.
NTF alarmAIS1.3.6.1.4.1.164.6.1.3.0.10This trap indicates AIS.
NTF alarmRDI1.3.6.1.4.1.164.6.1.3.0.11This trap indicates RDI.
NTF alarmFEBE1.3.6.1.4.1.164.6.1.3.0.12This trap indicates FEBE.
NTF localConnStatusTrap1.3.6.1.4.1.164.6.1.3.0.13This trap is sent upon a change in Local connectivity of Bundle connection.
NTF remoteConnStatusTrap1.3.6.1.4.1.164.6.1.3.0.14This trap is sent upon a change in Remote connectivity of Bundle connection.
NTF bundleConnectionStatusTrap1.3.6.1.4.1.164.6.1.3.0.15This trap is sent upon any change in the connectivity status of a Bundle (ip2IfOperStatus). The ifAlias index is the ifIndex of the bundle that its status has been changed.
radMP21001.3.6.1.4.1.164.6.1.3.1
radMP21041.3.6.1.4.1.164.6.1.3.2
radMP2100B1.3.6.1.4.1.164.6.1.3.3
radMP2100F1.3.6.1.4.1.164.6.1.3.4
radMP2100H1.3.6.1.4.1.164.6.1.3.5
radMP2104H1.3.6.1.4.1.164.6.1.3.6
radMP2200B1.3.6.1.4.1.164.6.1.3.7
radMP2200F1.3.6.1.4.1.164.6.1.3.8
radMX30001.3.6.1.4.1.164.6.1.3.9
radMX30041.3.6.1.4.1.164.6.1.3.10
radMX301.3.6.1.4.1.164.6.1.3.11
radMX3001.3.6.1.4.1.164.6.1.3.12
radVOIP1.3.6.1.4.1.164.6.1.3.13
radKM21001.3.6.1.4.1.164.6.1.3.15
radKM21041.3.6.1.4.1.164.6.1.3.16
radDXC301.3.6.1.4.1.164.6.1.3.20
radDXC10A1.3.6.1.4.1.164.6.1.3.21
radDXC8R1.3.6.1.4.1.164.6.1.3.22
radDXC30E1.3.6.1.4.1.164.6.1.3.23
radDXC30001.3.6.1.4.1.164.6.1.3.24
radDXC8RNew1.3.6.1.4.1.164.6.1.3.25
radFcdT1LC1.3.6.1.4.1.164.6.1.3.26
radFcdE1LC1.3.6.1.4.1.164.6.1.3.27
radFcdT1L1.3.6.1.4.1.164.6.1.3.28
radFcdE1L1.3.6.1.4.1.164.6.1.3.29
radFcdT11.3.6.1.4.1.164.6.1.3.30
radFcdE11.3.6.1.4.1.164.6.1.3.31
radFcdE1I1.3.6.1.4.1.164.6.1.3.32
radFcdT1M1.3.6.1.4.1.164.6.1.3.33
radFcdE1M1.3.6.1.4.1.164.6.1.3.34
radFcdIP1.3.6.1.4.1.164.6.1.3.35
radFcdT1A1.3.6.1.4.1.164.6.1.3.36
radFcdE1A1.3.6.1.4.1.164.6.1.3.37
radFcdW1.3.6.1.4.1.164.6.1.3.38
radFcdSTM1.3.6.1.4.1.164.6.1.3.39
radHtuE1Sa1.3.6.1.4.1.164.6.1.3.40
radHtuE11.3.6.1.4.1.164.6.1.3.41
radHtu2Sa1.3.6.1.4.1.164.6.1.3.42
radHtu21.3.6.1.4.1.164.6.1.3.43
radAsmi450R768Sa1.3.6.1.4.1.164.6.1.3.44
radAsmi450R7681.3.6.1.4.1.164.6.1.3.45
radAsmi450R1152Sa1.3.6.1.4.1.164.6.1.3.46
radAsmi450R11521.3.6.1.4.1.164.6.1.3.47
radLrs12F1.3.6.1.4.1.164.6.1.3.48
radLrs12B1.3.6.1.4.1.164.6.1.3.49
radLrs521.3.6.1.4.1.164.6.1.3.50
radHcdE1Sa1.3.6.1.4.1.164.6.1.3.51
radHcdE11.3.6.1.4.1.164.6.1.3.52
radHtuT1Sa1.3.6.1.4.1.164.6.1.3.53
radHtuT11.3.6.1.4.1.164.6.1.3.54
radOptimux4E11.3.6.1.4.1.164.6.1.3.55
radOptimux4T11.3.6.1.4.1.164.6.1.3.56
radOptimuxXLE11.3.6.1.4.1.164.6.1.3.57
radOptimuxXLT11.3.6.1.4.1.164.6.1.3.58
radOptimuxXL16E11.3.6.1.4.1.164.6.1.3.59
radImx641.3.6.1.4.1.164.6.1.3.60
radImx6L1.3.6.1.4.1.164.6.1.3.61
radImx21.3.6.1.4.1.164.6.1.3.62
radImx4T11.3.6.1.4.1.164.6.1.3.63
radImx4E11.3.6.1.4.1.164.6.1.3.64
radImx2T1E11.3.6.1.4.1.164.6.1.3.65
radIMXI41.3.6.1.4.1.164.6.1.3.66
radOptimux1551.3.6.1.4.1.164.6.1.3.67
radOptimux4T1L1.3.6.1.4.1.164.6.1.3.68
radOptimux4E1L1.3.6.1.4.1.164.6.1.3.69
radHtuE1SaV21.3.6.1.4.1.164.6.1.3.70
radHtuE1V21.3.6.1.4.1.164.6.1.3.71
radFomiE31.3.6.1.4.1.164.6.1.3.72
radFomiT31.3.6.1.4.1.164.6.1.3.73
radOpt4E1C1.3.6.1.4.1.164.6.1.3.74
radOpt4T1C1.3.6.1.4.1.164.6.1.3.75
radPrbiE31.3.6.1.4.1.164.6.1.3.76
radPrbiT31.3.6.1.4.1.164.6.1.3.77
radHcd4Sa1.3.6.1.4.1.164.6.1.3.78
radOptimuxT31.3.6.1.4.1.164.6.1.3.79
radFRmon1.3.6.1.4.1.164.6.1.3.80
radIpMux41.3.6.1.4.1.164.6.1.3.81
radIpMux11.3.6.1.4.1.164.6.1.3.82
radIpMux161.3.6.1.4.1.164.6.1.3.83
radIpMux1E1.3.6.1.4.1.164.6.1.3.84
radVmux21001.3.6.1.4.1.164.6.1.3.85
radMP1041.3.6.1.4.1.164.6.1.3.86
radMP2041.3.6.1.4.1.164.6.1.3.87
radVmux1101.3.6.1.4.1.164.6.1.3.88
radFcd1551.3.6.1.4.1.164.6.1.3.90
radIpMux81.3.6.1.4.1.164.6.1.3.91
radOptimux155DS31.3.6.1.4.1.164.6.1.3.92
radOptimuxT3L1.3.6.1.4.1.164.6.1.3.93
radGmux20001.3.6.1.4.1.164.6.1.3.94
radOp16E1L1.3.6.1.4.1.164.6.1.3.95
radOp16E1LS1.3.6.1.4.1.164.6.1.3.96
radPRBm201.3.6.1.4.1.164.6.1.3.97
radPRBm221.3.6.1.4.1.164.6.1.3.98
radAsmi52A1.3.6.1.4.1.164.6.1.3.99
radOpXLE11.3.6.1.4.1.164.6.1.3.100
radOpXLT11.3.6.1.4.1.164.6.1.3.101
radOpXL16E11.3.6.1.4.1.164.6.1.3.102
radOp4E11.3.6.1.4.1.164.6.1.3.103
radOp4T11.3.6.1.4.1.164.6.1.3.104
radDxc41.3.6.1.4.1.164.6.1.3.105
radIpMux111.3.6.1.4.1.164.6.1.3.106
radIpMux141.3.6.1.4.1.164.6.1.3.107
radOp15501.3.6.1.4.1.164.6.1.3.108
radFdsl1011.3.6.1.4.1.164.6.1.3.110
radFdsl2011.3.6.1.4.1.164.6.1.3.111
radVmux1201.3.6.1.4.1.164.6.1.3.112
radVmux22001.3.6.1.4.1.164.6.1.3.113
radVmux4001.3.6.1.4.1.164.6.1.3.114
radIpMux1161.3.6.1.4.1.164.6.1.3.115
radOp4E1LNew1.3.6.1.4.1.164.6.1.3.116
radOp4T1LNew1.3.6.1.4.1.164.6.1.3.117
radFcd155E1.3.6.1.4.1.164.6.1.3.118
radFcd155ES1.3.6.1.4.1.164.6.1.3.119
radMP41001.3.6.1.4.1.164.6.1.3.120
radAsmi52L1.3.6.1.4.1.164.6.1.3.121
radVmux2101.3.6.1.4.1.164.6.1.3.122
radOp34E11.3.6.1.4.1.164.6.1.3.123
radVmux3121.3.6.1.4.1.164.6.1.3.124
radVmux4041.3.6.1.4.1.164.6.1.3.125
radVmux4201.3.6.1.4.1.164.6.1.3.126
radIpMux121.3.6.1.4.1.164.6.1.3.127
radOptimux4E1V3dot51.3.6.1.4.1.164.6.1.3.128
radOptimux4E1Mar061.3.6.1.4.1.164.6.1.3.129
radFcd155EwAPS1.3.6.1.4.1.164.6.1.3.130
radOptimux4T1Mar061.3.6.1.4.1.164.6.1.3.131
radFcd155EwAPS2pdh1.3.6.1.4.1.164.6.1.3.132
radVmux3201.3.6.1.4.1.164.6.1.3.133
radMP2100VoIP1.3.6.1.4.1.164.6.1.3.134
radMP2104VoIP1.3.6.1.4.1.164.6.1.3.135
radIpMux241.3.6.1.4.1.164.6.1.3.136
radOp4E1NG11.3.6.1.4.1.164.6.1.3.137
radOp4T1NG11.3.6.1.4.1.164.6.1.3.138
radOp251.3.6.1.4.1.164.6.1.3.139
radAsmi541.3.6.1.4.1.164.6.1.3.140
radVmux3141.3.6.1.4.1.164.6.1.3.141
radFcd6221.3.6.1.4.1.164.6.1.3.142
radLrs221.3.6.1.4.1.164.6.1.3.143
radUNT20E11.3.6.1.4.1.164.6.1.3.144
radIpMux2L1.3.6.1.4.1.164.6.1.3.145
radUNT20Fcd1.3.6.1.4.1.164.6.1.3.146
radIpMux2161.3.6.1.4.1.164.6.1.3.147
radLrs1021.3.6.1.4.1.164.6.1.3.148
radGmux20041.3.6.1.4.1.164.6.1.3.149
radLrs102unbal1.3.6.1.4.1.164.6.1.3.150
radLrs161.3.6.1.4.1.164.6.1.3.151
radVmux4051.3.6.1.4.1.164.6.1.3.152
radVmux4251.3.6.1.4.1.164.6.1.3.153
radMiniCVS1.3.6.1.4.1.164.6.1.3.154
radSysBRG1.3.6.1.4.1.164.6.1.4
radTRE11.3.6.1.4.1.164.6.1.4.1
radTRE1D1.3.6.1.4.1.164.6.1.4.2
radTRE81.3.6.1.4.1.164.6.1.4.3
radTRE8D1.3.6.1.4.1.164.6.1.4.4
radMBE11.3.6.1.4.1.164.6.1.4.5
radMBE1D1.3.6.1.4.1.164.6.1.4.6
radMBE81.3.6.1.4.1.164.6.1.4.7
radMBE8D1.3.6.1.4.1.164.6.1.4.8
radMLBT1.3.6.1.4.1.164.6.1.4.9
radFEB4DAS1.3.6.1.4.1.164.6.1.4.10
radTrimBrg101.3.6.1.4.1.164.6.1.4.11
radTrimBrg161.3.6.1.4.1.164.6.1.4.12
radRRTRE81.3.6.1.4.1.164.6.1.4.13
radRRTRE8D1.3.6.1.4.1.164.6.1.4.14
radRRMLBT1.3.6.1.4.1.164.6.1.4.15
radRRMLBTF1.3.6.1.4.1.164.6.1.4.16
radRRTRE1D1.3.6.1.4.1.164.6.1.4.17
radTRERAS1.3.6.1.4.1.164.6.1.4.18
radTRERASa1.3.6.1.4.1.164.6.1.4.19
radMBERAS1.3.6.1.4.1.164.6.1.4.20
radMBERASa1.3.6.1.4.1.164.6.1.4.21
radFEB4FDX1.3.6.1.4.1.164.6.1.4.22
radFEB4SAS1.3.6.1.4.1.164.6.1.4.23
radRRFTBDAS1.3.6.1.4.1.164.6.1.4.24
radRRFTBSAS1.3.6.1.4.1.164.6.1.4.25
radFTBDAS1.3.6.1.4.1.164.6.1.4.26
radFTBSAS1.3.6.1.4.1.164.6.1.4.27
radFastWay1001.3.6.1.4.1.164.6.1.4.28
radSysCnvrtr1.3.6.1.4.1.164.6.1.5
radSTC11.3.6.1.4.1.164.6.1.5.1
radSTC21.3.6.1.4.1.164.6.1.5.3
radSTC1UDP1.3.6.1.4.1.164.6.1.5.4
radSTC2UDP1.3.6.1.4.1.164.6.1.5.6
radFTC11.3.6.1.4.1.164.6.1.5.10
radFTC21.3.6.1.4.1.164.6.1.5.12
radFTC1UDP1.3.6.1.4.1.164.6.1.5.13
radFTC2UDP1.3.6.1.4.1.164.6.1.5.15
radSEC11.3.6.1.4.1.164.6.1.5.20
radSEC21.3.6.1.4.1.164.6.1.5.22
radSEC1UDP1.3.6.1.4.1.164.6.1.5.23
radSEC2UDP1.3.6.1.4.1.164.6.1.5.25
radFEC11.3.6.1.4.1.164.6.1.5.30
radFEC21.3.6.1.4.1.164.6.1.5.32
radFEC1UDP1.3.6.1.4.1.164.6.1.5.33
radFEC2UDP1.3.6.1.4.1.164.6.1.5.35
radRIC1551.3.6.1.4.1.164.6.1.5.36
radRICE11.3.6.1.4.1.164.6.1.5.37
radETX1021.3.6.1.4.1.164.6.1.5.38
radRIC155GE1.3.6.1.4.1.164.6.1.5.39
radRiciT31.3.6.1.4.1.164.6.1.5.40
radRiciE31.3.6.1.4.1.164.6.1.5.41
radRiciT11.3.6.1.4.1.164.6.1.5.42
radETX2021.3.6.1.4.1.164.6.1.5.43
radETX1051.3.6.1.4.1.164.6.1.5.44
radETX2051.3.6.1.4.1.164.6.1.5.45
radRiciSE1.3.6.1.4.1.164.6.1.5.46
radRIC622GE1.3.6.1.4.1.164.6.1.5.47
radSPH1.3.6.1.4.1.164.6.1.5.48
radMiricE1T11.3.6.1.4.1.164.6.1.5.49
radMiricE3T31.3.6.1.4.1.164.6.1.5.50
radEthAccess1.3.6.1.4.1.164.6.1.6
radETX5101.3.6.1.4.1.164.6.1.6.1
radEGate1001.3.6.1.4.1.164.6.1.6.2
radEGate201.3.6.1.4.1.164.6.1.6.3
radRici8E11.3.6.1.4.1.164.6.1.6.4
radRici8T11.3.6.1.4.1.164.6.1.6.5
radRici4E11.3.6.1.4.1.164.6.1.6.6
radRici4T11.3.6.1.4.1.164.6.1.6.7
radETX5501.3.6.1.4.1.164.6.1.6.9
radRici161.3.6.1.4.1.164.6.1.6.10
radETX102A1.3.6.1.4.1.164.6.1.6.11
radETX202A1.3.6.1.4.1.164.6.1.6.12
radETX201A1.3.6.1.4.1.164.6.1.6.13
radETX2011.3.6.1.4.1.164.6.1.6.14
radUNT20Ric1.3.6.1.4.1.164.6.1.6.15
radRici4E1L1.3.6.1.4.1.164.6.1.6.16
radRici8E1L1.3.6.1.4.1.164.6.1.6.17
radRici155GE1.3.6.1.4.1.164.6.1.6.18
radRici622GE1.3.6.1.4.1.164.6.1.6.19
radETX2081.3.6.1.4.1.164.6.1.6.20
radETX202AW1.3.6.1.4.1.164.6.1.6.21
radETX102H1.3.6.1.4.1.164.6.1.6.22
radETX202H1.3.6.1.4.1.164.6.1.6.23
radSysStkHub1.3.6.1.4.1.164.6.1.7
radRBHE1.3.6.1.4.1.164.6.1.7.1
radRBHEEvents1.3.6.1.4.1.164.6.1.7.1.0The events for RAD Stackable products.
radRBHT1.3.6.1.4.1.164.6.1.7.2
radRBHTEvents1.3.6.1.4.1.164.6.1.7.2.0The events for RAD Stackable products.
radETS4fddiDAS1.3.6.1.4.1.164.6.1.7.3
radETS4fddiSAS1.3.6.1.4.1.164.6.1.7.4
radSAHEMX1.3.6.1.4.1.164.6.1.7.5
radSAHTM1.3.6.1.4.1.164.6.1.7.6
radETS41.3.6.1.4.1.164.6.1.7.7
radSAHEMU1.3.6.1.4.1.164.6.1.7.8
unknown1.3.6.1.4.1.164.6.1.7.9
radSAH16Eint1.3.6.1.4.1.164.6.1.7.10
radSAH16Tint1.3.6.1.4.1.164.6.1.7.11
radSAH16Eext1.3.6.1.4.1.164.6.1.7.12
radSAH16Text1.3.6.1.4.1.164.6.1.7.13
radSysPS1.3.6.1.4.1.164.6.1.8
radSysPSEvents1.3.6.1.4.1.164.6.1.8.0The events for RAD Packet Switch (PS) products.
radSPS21.3.6.1.4.1.164.6.1.8.1
radSPS31.3.6.1.4.1.164.6.1.8.2
radSPS61.3.6.1.4.1.164.6.1.8.3
radSPS91.3.6.1.4.1.164.6.1.8.4
radSPS121.3.6.1.4.1.164.6.1.8.5
radAPD21.3.6.1.4.1.164.6.1.8.6
radAPD81.3.6.1.4.1.164.6.1.8.7
radAPS81.3.6.1.4.1.164.6.1.8.8
radAPS161.3.6.1.4.1.164.6.1.8.9
radAPS241.3.6.1.4.1.164.6.1.8.10
radSPS3S1.3.6.1.4.1.164.6.1.8.11
radFPS81.3.6.1.4.1.164.6.1.8.12
radFPS121.3.6.1.4.1.164.6.1.8.13
radSPS3ScSL1.3.6.1.4.1.164.6.1.8.14
radSPS3Sc2S1.3.6.1.4.1.164.6.1.8.15
radFPS8c1.3.6.1.4.1.164.6.1.8.16
radFPS41.3.6.1.4.1.164.6.1.8.17
radSPS41.3.6.1.4.1.164.6.1.8.18
radSysEth1.3.6.1.4.1.164.6.1.9
radEP8T1.3.6.1.4.1.164.6.1.9.1
radEP4TAUI1.3.6.1.4.1.164.6.1.9.2
radEP4T2FL1.3.6.1.4.1.164.6.1.9.3
radEP4TFL1.3.6.1.4.1.164.6.1.9.4
radEP4FL1.3.6.1.4.1.164.6.1.9.5
radEPR8T1.3.6.1.4.1.164.6.1.9.7
radEPR4TAUI1.3.6.1.4.1.164.6.1.9.8
radEPR4T2FL1.3.6.1.4.1.164.6.1.9.9
radEPR4TFL1.3.6.1.4.1.164.6.1.9.10
radEPR4FL1.3.6.1.4.1.164.6.1.9.11
radSysRtr1.3.6.1.4.1.164.6.1.11
radSysRtrEvents1.3.6.1.4.1.164.6.1.11.0The events for RAD Router products.
radRTED1.3.6.1.4.1.164.6.1.11.1
radRTEM1.3.6.1.4.1.164.6.1.11.2
radRTEC1.3.6.1.4.1.164.6.1.11.3
radWebRanger1.3.6.1.4.1.164.6.1.11.4
radTinyRouter1.3.6.1.4.1.164.6.1.11.5
radLA2401.3.6.1.4.1.164.6.1.11.6
radSuperLan1.3.6.1.4.1.164.6.1.11.7
radLA240I1.3.6.1.4.1.164.6.1.11.8
radFcdIsdn1.3.6.1.4.1.164.6.1.11.9
radEFcdIp1.3.6.1.4.1.164.6.1.11.10
radFcdIpD1.3.6.1.4.1.164.6.1.11.11
radFcdIpM1.3.6.1.4.1.164.6.1.11.12
radFcdIpL1.3.6.1.4.1.164.6.1.11.13
radSysAtm1.3.6.1.4.1.164.6.1.12
radSysAtmEvents1.3.6.1.4.1.164.6.1.12.0The events for RAD ATM products.
NTF atmAceSystemTrap1.3.6.1.4.1.164.6.1.12.0.6This trap alerts of major problems in the device.
NTF atmAceAlarmForwardingTrap1.3.6.1.4.1.164.6.1.12.0.7This trap is sent upon starting or stopping Alarm Forwarding Mechanism.
NTF atmAceDateAndTimeRequest1.3.6.1.4.1.164.6.1.12.0.8This trap is sent upon restart. Upon recieving this trap the NMS will set the device's date and time. This trap's purpose is to fix a problem in ACE2002, ACE-2002E, ACE-202. The problem is that the Date and Time is stored in the NVRAM, and when the NVRAM's battery is empty, the device loses this information.
NTF atmAceAlarmLOS1.3.6.1.4.1.164.6.1.12.0.16This trap indicates Loss Of Signal.
NTF atmAceAlarmLOF1.3.6.1.4.1.164.6.1.12.0.17This trap indicates Loss Of Frame.
NTF atmAceAlarmLCD1.3.6.1.4.1.164.6.1.12.0.18This trap indicates Loss of Cell Delineation.
NTF atmAceAlarmSLM1.3.6.1.4.1.164.6.1.12.0.19This trap indicates Signal Line Mismatch.
NTF atmAceAlarmLOP1.3.6.1.4.1.164.6.1.12.0.20This trap indicates Loss of Pointer.
NTF atmAceAlarmLineAIS1.3.6.1.4.1.164.6.1.12.0.21This trap indicates Line AIS.
NTF atmAceAlarmPathAIS1.3.6.1.4.1.164.6.1.12.0.22This trap indicates Path AIS.
NTF atmAceAlarmLineRDI1.3.6.1.4.1.164.6.1.12.0.23This trap indicates Line RDI.
NTF atmAceAlarmPathRDI1.3.6.1.4.1.164.6.1.12.0.24This trap indicates Path RDIand Path RAI(Yellow) for DS1 interfaces.
NTF atmAceAlarmSectionBIP1.3.6.1.4.1.164.6.1.12.0.25This trap indicates Section Bit Interleave Parity.
NTF atmAceAlarmLineBIP1.3.6.1.4.1.164.6.1.12.0.26This trap indicates Line Bit Interleave Parity.
NTF atmAceAlarmPathBIP1.3.6.1.4.1.164.6.1.12.0.27This trap indicates Path Bit Interleave Parity.
NTF atmAceAlarmLineFEBE1.3.6.1.4.1.164.6.1.12.0.28This trap indicates Line Far End Block Error.
NTF atmAceAlarmPathFEBE1.3.6.1.4.1.164.6.1.12.0.29This trap indicates Path Far End Block Error.
NTF atmAceAlarmPlcpLOF1.3.6.1.4.1.164.6.1.12.0.30This trap indicates T3 PLCP Loss Of Frame.
NTF atmAceAlarmPlcpYELLOW1.3.6.1.4.1.164.6.1.12.0.31This trap indicates T3 Plcp Yellow.
NTF atmAceAlarmPlcpBIP1.3.6.1.4.1.164.6.1.12.0.32This trap indicates T3 Plcp Bit Interleave Parity.
NTF atmAceAlarmPlcpFEBE1.3.6.1.4.1.164.6.1.12.0.33This trap indicates T3 Plcp Far End Block Error.
NTF atmAceAlarmPlcpP1P21.3.6.1.4.1.164.6.1.12.0.34This trap indicates T3 Plcp Parity errors in P1/P2 bytes.
NTF atmAceAlarmUAS1.3.6.1.4.1.164.6.1.12.0.35This trap is sent upon UAS start or end per port.
NTF atmAceAlarmCluster1.3.6.1.4.1.164.6.1.12.0.36This trap is sent upon atmNteAlarmType start or end, for a cluster of VPs/VCs (according to atmNteLevel) with the same alarm on the same physical port. This trap replaces sending the same alarm for a big quantity (the quantity described in the product specification document) of VPs/VCs in order to prevent flooding the NMS and the network with traps.
NTF atmAceHwFailure1.3.6.1.4.1.164.6.1.12.0.37This trap is sent upon HW failure per port.
NTF atmAceUnavailableBwTrap1.3.6.1.4.1.164.6.1.12.0.38This trap is sent when Bandwidth allocation is > max possible value for the installed card. For ACE2002 this trap will be sent for the following cases: Card insertion - if the total Input and/or Output Bandwidth is over allocated, then the specific card rate will be set to 0 and this trap will be sent with the Input/Output rates values. Upgrade from former version - when an over allocated Bandwidth is detected, this trap will be sent with atmConfIfInputRate=atmConfIfOutputRate=0xFFFFFFFF.
NTF atmAceAlarmVpContinuityLoss1.3.6.1.4.1.164.6.1.12.0.40This trap indicates Loss of Continuity Check on a VP Connection.
NTF atmAceAlarmVpAISReception1.3.6.1.4.1.164.6.1.12.0.41This trap indicates AIS Reception on a VP Connection.
NTF atmAceAlarmVpRDIReception1.3.6.1.4.1.164.6.1.12.0.42This trap indicates RDI Reception on a VP Connection.
NTF atmAceAlarmVpErroredCells1.3.6.1.4.1.164.6.1.12.0.43This trap indicates Errored Cells on a VP Connection reported by PM.
NTF atmAceAlarmVpLostCells1.3.6.1.4.1.164.6.1.12.0.44This trap indicates Lost Cells on a VP Connection reported by PM.
NTF atmAceAlarmVpMisinsertedCells1.3.6.1.4.1.164.6.1.12.0.45This trap indicates Misinserted Cells on a VP Connection reported by PM.
NTF atmAceAlarmVpUAS1.3.6.1.4.1.164.6.1.12.0.46This trap is sent upon UAS start or end per VP.
NTF atmAceAlarmVpLoopback1.3.6.1.4.1.164.6.1.12.0.47This trap is sent upon OAM LoopBack fail status per VP.
NTF atmAceAlarmVpGCRAViolation1.3.6.1.4.1.164.6.1.12.0.48This trap indicates GCRA violation on a VP Connection reported by UPC device.
NTF atmAceAlarmVcContinuityLoss1.3.6.1.4.1.164.6.1.12.0.56This trap indicates Loss of Continuity Check on a VC Connection.
NTF atmAceAlarmVcAISReception1.3.6.1.4.1.164.6.1.12.0.57This trap indicates AIS Reception on a VC.
NTF atmAceAlarmVcRDIReception1.3.6.1.4.1.164.6.1.12.0.58This trap indicates RDI Reception on a VC Connection.
NTF atmAceAlarmVcErroredCells1.3.6.1.4.1.164.6.1.12.0.59This trap indicates Errored Cells on a VC Connection reported by PM.
NTF atmAceAlarmVcLostCells1.3.6.1.4.1.164.6.1.12.0.60This trap indicates Lost Cells on a VC Connection reported by PM.
NTF atmAceAlarmVcMisinsertedCells1.3.6.1.4.1.164.6.1.12.0.61This trap indicates Misinserted Cells on a VC Connection reported by PM.
NTF atmAceAlarmVcUnexpectedCell1.3.6.1.4.1.164.6.1.12.0.62This trap indicates an unexpected cell from user or network port.
NTF atmAceAlarmVcUAS1.3.6.1.4.1.164.6.1.12.0.63This trap is sent upon UAS start or end per VC.
NTF atmAceAlarmVcLoopback1.3.6.1.4.1.164.6.1.12.0.64This trap is sent upon OAM LoopBack fail status per VC.
NTF atmAceAlarmVcGCRAViolation1.3.6.1.4.1.164.6.1.12.0.65This trap indicates GCRA violation on a VC Connection reported by UPC device.
radStarSwitch1.3.6.1.4.1.164.6.1.12.1
radStarSwitchATM251.3.6.1.4.1.164.6.1.12.1.1
radStarSwitchATM25L1.3.6.1.4.1.164.6.1.12.1.2
radStarSwitchATM1551.3.6.1.4.1.164.6.1.12.1.3
radAtmCsuDsu1.3.6.1.4.1.164.6.1.12.2
radAmcdE11.3.6.1.4.1.164.6.1.12.2.1
radAmcdT11.3.6.1.4.1.164.6.1.12.2.2
radAce20E1.3.6.1.4.1.164.6.1.12.2.3
radAce20T1.3.6.1.4.1.164.6.1.12.2.4
radAce20051.3.6.1.4.1.164.6.1.12.2.5
radAce20021.3.6.1.4.1.164.6.1.12.2.6
radAce2002E1.3.6.1.4.1.164.6.1.12.2.7
radAce2E1.3.6.1.4.1.164.6.1.12.2.8
radAce2T1.3.6.1.4.1.164.6.1.12.2.9
radMlAtmE11.3.6.1.4.1.164.6.1.12.2.10
radMlAtmT11.3.6.1.4.1.164.6.1.12.2.11
radAmc1021.3.6.1.4.1.164.6.1.12.2.12
radAmc102c1.3.6.1.4.1.164.6.1.12.2.13
radAce2021.3.6.1.4.1.164.6.1.12.2.14
radAce1.3.6.1.4.1.164.6.1.12.3
radAce1011.3.6.1.4.1.164.6.1.12.3.1
radAce1021.3.6.1.4.1.164.6.1.12.3.2
radAce501.3.6.1.4.1.164.6.1.12.3.3
radAce521.3.6.1.4.1.164.6.1.12.3.4
radAce52L1.3.6.1.4.1.164.6.1.12.3.5
radAce2011.3.6.1.4.1.164.6.1.12.3.7
radAce32001.3.6.1.4.1.164.6.1.12.3.8
radAce31001.3.6.1.4.1.164.6.1.12.3.9
radAce34001.3.6.1.4.1.164.6.1.12.3.10
radAce34021.3.6.1.4.1.164.6.1.12.3.11
radAce3100PSN1.3.6.1.4.1.164.6.1.12.3.12
radAce3200PSN1.3.6.1.4.1.164.6.1.12.3.13
radAce3400PSN1.3.6.1.4.1.164.6.1.12.3.14
radAce3402PSN1.3.6.1.4.1.164.6.1.12.3.15
radAce36001.3.6.1.4.1.164.6.1.12.3.16
radAce32051.3.6.1.4.1.164.6.1.12.3.17
radAce31051.3.6.1.4.1.164.6.1.12.3.18
radSysLA1.3.6.1.4.1.164.6.1.13
radLA1401.3.6.1.4.1.164.6.1.13.1
radLA1101.3.6.1.4.1.164.6.1.13.2
radLA1041.3.6.1.4.1.164.6.1.13.3
radLA1301.3.6.1.4.1.164.6.1.13.4
radLA2101.3.6.1.4.1.164.6.1.13.5
radSysTerminal1.3.6.1.4.1.164.6.1.100
agnt1.3.6.1.4.1.164.6.2
STR agnHwVersion1.3.6.1.4.1.164.6.2.1DisplayStringread-writeASCII string for description and display of the agent hardware version, as it is known by the agent software.The user can update the version upon request when he changes components in the agent's module
I32 agnTrapMask1.3.6.1.4.1.164.6.2.2Integer32read-writeThe value of this attribute determines the type of traps the agent should mask and not send to the management console. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed.
OCT agnTrapValue1.3.6.1.4.1.164.6.2.3OCTET STRINGread-onlyThe value of the trap decoded in internal RAD format. Full description is given in the Trap definition file
C32 agnChangeCnt1.3.6.1.4.1.164.6.2.4Counter32read-onlyThe number of changes in system configuration that were reported to the manager since last cold start
OID agnSpecific1.3.6.1.4.1.164.6.2.5OBJECT IDENTIFIERread-onlyObject identifier of entity containing additional information regarding this instance.
OCT agnConfigMsg1.3.6.1.4.1.164.6.2.6OCTET STRINGread-onlyFull configuration message coded in internal RAD application format. This entry describes agent's configuration. For MP-2200 R3, this object describes agent's support of the V5.1 feature: 1 octet ; bit 0 (LSB). '1' - V5.1 feature is supported '0' - V5.1 feature is not supported.
mngTrapIpTable1.3.6.1.4.1.164.6.2.7not-accessibleThis table indicates the destination address of the traps. Internally it will be limited to ten addresses.
mngEntry1.3.6.1.4.1.164.6.2.7.1not-accessibleAn entry in table.
I32 mngID1.3.6.1.4.1.164.6.2.7.1.1Integer32read-onlyThis value indicates an index of a specific IP address
IP mngIP1.3.6.1.4.1.164.6.2.7.1.2IpAddressread-writeThis value indicates the destination address of the traps. IP 0.0.0.0 removes the entry.
IP mngIPMask1.3.6.1.4.1.164.6.2.7.1.3IpAddressread-writeThis value indicates the mask of the destination addresses of the traps.
I32 mngTrapMask1.3.6.1.4.1.164.6.2.7.1.4Integer32read-writeThe value of this attribute determines the type of traps the agent should mask and not send to this NMS. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed.
OCT mngAlarmTrapMask1.3.6.1.4.1.164.6.2.7.1.5OCTET STRINGread-writeThe value of this object determines the alarm traps that the agent should mask (not send to this manager). The value is an Octet String, where each bit is assigned to a certain trap. If the bit = 1, the trap will be masked. If the bit = 0, the trap will not be masked. For more details on the specific alarm traps masked, see product specification.
U32 mngSnmpTrapUdpPort1.3.6.1.4.1.164.6.2.7.1.6Unsigned32read-writeThis variable enables to set the UDP port (socket) used for SNMP traps.
INT agnIndication1.3.6.1.4.1.164.6.2.8INTEGERread-onlyAttribute describing the state of the entity the agent is responsible for. In case of a modular entity, the value of this attribute will be according to the component which is in the worst state. The order of severity (from top to bottom) is: critical-> major (or faulty)-> minor-> event-> warning-> normal (off).
INT agnMonitorModeCmd1.3.6.1.4.1.164.6.2.9INTEGERread-writeSetting this attribute to ON, will enforce the agent to change its mode of operation to Monitor Mode
OCT agnLed1.3.6.1.4.1.164.6.2.10OCTET STRINGread-onlyThis entry specifies the LEDs status of the agent module . Each led will be represented by 4 bits where the first 2 bits (left) will specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) will specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY)
trapTable1.3.6.1.4.1.164.6.2.11not-accessibleThis table may include the last few traps generated by the agent, for future retrieval. The table has a limited capacity. If traps are not retrieved in proper time, they will be over-written by new traps. For other devices, it can include generic variables that will be attached to traps as 'accessible-for-notify'.
trapEntry1.3.6.1.4.1.164.6.2.11.1not-accessibleAn entry in trapTable.
I32 trapID1.3.6.1.4.1.164.6.2.11.1.1Integer32read-onlyThis object indicates an index of a specific trap. Can be used also for any trap, while trapVal is used as 'accessible-for-notify' or trapNumeric is used.
STR trapVal1.3.6.1.4.1.164.6.2.11.1.2DisplayStringread-onlyThis object is the actual ASCII description of the trap. It can be used also as attached variable of traps, in order to detail in explicit ASCII text, data of the trap. In this case, it is used as 'accessible-for-notify'.
TIK trapTimeSinceOccurrence1.3.6.1.4.1.164.6.2.11.1.3TimeTicksread-onlyThis object indicates the amount of time passed since the occurrence of the event that triggered this trap.
I32 trapNumeric1.3.6.1.4.1.164.6.2.11.1.4Integer32accessible-for-notifyThis object is a numeric general parameter, that can be attached to any trap. Values can be positive or negative.
fileTransfer1.3.6.1.4.1.164.6.2.12
IP fileServerIP1.3.6.1.4.1.164.6.2.12.1IpAddressread-writeThe IP address of the server from which the file is loaded
STR fileName1.3.6.1.4.1.164.6.2.12.2DisplayStringread-writeThe name of the file to be loaded. For protection, read returns NULL.
INT fileTransCmd1.3.6.1.4.1.164.6.2.12.3INTEGERread-writeThe command to be executed on fileName at fileServerIP.
I32 tftpRetryTimeOut1.3.6.1.4.1.164.6.2.12.4Integer32read-writeGeneral Retransmission time-out value (seconds)
I32 tftpTotalTimeOut1.3.6.1.4.1.164.6.2.12.5Integer32read-writeTotal Retransmission time-out value (seconds)
INT tftpStatus1.3.6.1.4.1.164.6.2.12.6INTEGERread-writeStatus of tftp session. When a session ended with success, the tftpStatus should be endedOk(6). Before restarting a tftp session, the NMS should set the tftpStatus to noOp(2). That's the reason of MAX-ACCESS read-write to this field.
OCT tftpError1.3.6.1.4.1.164.6.2.12.7OCTET STRINGread-onlyThe MSB represents the standard error code. The LSB represents the private error code. 0x0000 is No Error 0x0100 is File Not Found 0x0200 is Access violation 0x0300 is Disk full or allocation exceeded 0x0400 is Illegal TFTP operation 0x0500 is Unknown transfer ID 0x0600 is File already exists 0x0700 is No such user 0x0001 is Server Overflow 0x0002 is No empty UDP port 0x0003 is No empty connection 0x0004 is Illegal File Mode 0x0007 is Illegal PDU size 0x0008 is TFTP Server does not exist 0x0009 is Incorrect File 0x000A is Wrong License format 0x000B is License ID already used
OCT fileTransferToSubSystems1.3.6.1.4.1.164.6.2.12.8OCTET STRINGread-writeThis object represents the sub-systems the fileTransCmd refers to. It should be used when a system is divided to sub-systems and each sub-system (or part of them) can have a different SW/Configuration. Each bit of this object will represent one of the sub-systems. Bit='1' - APPLY to respective sub-system Bit='0' - DO NOT APPLY to respective sub-system For the meaning of each bit, see product's specification. User will select the sub-systems envolved by filling-in the bits that represent these sub-systems. In this case, the file represented by 'fileName' will include several parts, each representing one of the sub-systems. The agent will refer only to the part/s indicated by this object. 0 Octet Strings = not applicable DEFVAL = 0h for the products that support this object.
STR fileNameWithinProduct1.3.6.1.4.1.164.6.2.12.9DisplayStringread-writeThe file name used by the product within the product file system.
intSwdlTable1.3.6.1.4.1.164.6.2.12.10not-accessibleThis parameters table is for internal Software down load. It also includes data about all files contained in the Object from which down-load is performed.
intSwdlEntry1.3.6.1.4.1.164.6.2.12.10.1not-accessibleAn entry in table.
I32 intSwdlObjIdx1.3.6.1.4.1.164.6.2.12.10.1.1Integer32read-onlyThe index of the object from which down-load is performed.
I32 intSwdlFileIdx1.3.6.1.4.1.164.6.2.12.10.1.2Integer32read-onlyThe index of the files included in intSwdlObjIdx. One of these files can be selected to be internally downloaded.
STR intSwdlFileName1.3.6.1.4.1.164.6.2.12.10.1.3DisplayStringread-onlyThe name of the file.
STR intSwdlFileSwVer1.3.6.1.4.1.164.6.2.12.10.1.4DisplayStringread-onlyThe software version of the file.
STR intSwdlSwDate1.3.6.1.4.1.164.6.2.12.10.1.5DisplayStringread-onlyThe software version date of the file.
STR intSwdlSize1.3.6.1.4.1.164.6.2.12.10.1.6DisplayStringread-onlyThe size of the file.
INT intSwdlCmd1.3.6.1.4.1.164.6.2.12.10.1.7INTEGERread-writeThe command to down-load a SW file to an object. The Agent will change the value of this MIB object to off(2) automatically, after accepting the command.
OCT intSwdlToSubSystem1.3.6.1.4.1.164.6.2.12.10.1.8OCTET STRINGread-writeThis object defines the subsystem for download. Bit='1'- APPLY to respective sub system. Bit='0'- DO NOT APPLY to respective sub system. For more details see product specification. For every octet bit0=LSB, bit7=MSB
INT intSwdlCardType1.3.6.1.4.1.164.6.2.12.10.1.9INTEGERread-onlyThis object defines the Card type that this file is relevant for.
I32 intSwdlFlashIdx1.3.6.1.4.1.164.6.2.12.10.1.10Integer32read-onlyThe index of the flash memory this file is stored in (1 or 2) (Example: 1= The file is stored in flash No.1). ASMi52 file will always be stored in Flash No.2 (intSwdlFlashIdx=2).
swdlStatusTable1.3.6.1.4.1.164.6.2.12.11not-accessibleThis parameters table is for software download status. It also includes data about the files down-loaded or attempted to be down-loaded.
swdlStatusEntry1.3.6.1.4.1.164.6.2.12.11.1not-accessibleAn entry in table.
I32 swdlStatusTypeIdx1.3.6.1.4.1.164.6.2.12.11.1.1Integer32read-onlyThe index of the down-load type (e.g. external (1) or internal (2)).
I32 swdlStatusIdx1.3.6.1.4.1.164.6.2.12.11.1.2Integer32read-onlyThe index of the status rows.
STR swdlStatusFileName1.3.6.1.4.1.164.6.2.12.11.1.3DisplayStringread-onlyThe name of the file.
STR swdlStatusSlot1.3.6.1.4.1.164.6.2.12.11.1.4DisplayStringread-onlyThe slot of the updated (or attempted to be updated) object.
STR swdlStatusSubSystem1.3.6.1.4.1.164.6.2.12.11.1.5DisplayStringread-onlyThe subsystem that updated (or attempted to be updated).
I32 swdlStatusStatus1.3.6.1.4.1.164.6.2.12.11.1.6Integer32read-onlyThe status of the down load process. Value: Fail (2), OK (3), InProcess (4).
STR swdlStatusTime1.3.6.1.4.1.164.6.2.12.11.1.7DisplayStringread-onlyThis MIB parameter indicates the time SW download was finished. The format shuld be YYYY-MM-DD, hh:mm:ss
I32 clearDwldStatusLog1.3.6.1.4.1.164.6.2.12.12Integer32read-writeThis object clears the status log. Value: off(2), external(3), internal(4) The Agent will change the value of this MIB object to off(2) automatically, after accepting the command .
autoFileTransfer1.3.6.1.4.1.164.6.2.12.13
autoFileTransferTable1.3.6.1.4.1.164.6.2.12.13.1not-accessibleScheduling configuration table for Agent initiated file transfer.
autoFileTransferEntry1.3.6.1.4.1.164.6.2.12.13.1.1not-accessibleAn entry in the table.
INT autoFileTransferType1.3.6.1.4.1.164.6.2.12.13.1.1.1INTEGERread-onlyThis object defines the type of file to be transferred by agent.
IP autoFileTransferServerIp1.3.6.1.4.1.164.6.2.12.13.1.1.2IpAddressread-writeThis object defines the IP Address of the server to which the file is uploaded.
STR autoFileTransferFileName1.3.6.1.4.1.164.6.2.12.13.1.1.3SnmpAdminStringread-writeThis object defines the name of the file to be uploaded.
INT autoFileTransferScheduling1.3.6.1.4.1.164.6.2.12.13.1.1.4INTEGERread-writeThis object defines schedule for TFTP Automatic session(s) initiated by Agent, according to the value selected: now - initiate immediate single session. recurrence- initiate single session 'every M time units'. or 'every N occurrences' or upon both, (earliest event). Time reccurence period (M) is defined by fileTransferTimeRecurrence. Occurrence reccurence (N) is defined by fileTransferOccurrenceRecurrence. Zero value means that the object is not relevant (not taken into account for the recurrence). It is invalid that both will have zero values in our case (recurrence). When both are non zero, file is transferred upon earliest event
I32 autoFileTransferTimeRecurrence1.3.6.1.4.1.164.6.2.12.13.1.1.5Integer32read-writeThis object defines time reccurence interval, e.g. M can be 'every M days', 'every M hours' etc. Zero is used to indicate there's no time reccurence (0= notApplicable). This object is taken into account only if autoFileTransferScheduling = recurrence For LA-110 time units are days.
I32 autoFileTransferOccurrenceRecurrence1.3.6.1.4.1.164.6.2.12.13.1.1.6Integer32read-writeThis object defines Occurrence reccurence interval, e.g N can be in 'every N alarms', 'every N log entries' etc. zero is used to indicate There's no Event Reccurence. (0= notApplicable) This object is taken into account only if autoFileTransferScheduling = recurrence Occurence Type (Alarms, etc.) is according to autoFileTransferType.
U32 fileTransferServerPort1.3.6.1.4.1.164.6.2.12.14Unsigned32read-writeServer Port number used for File Transfer. Applicable for SFTP. Valid values: 0..65535.
INT fileTransferProtocol1.3.6.1.4.1.164.6.2.12.15INTEGERread-writeFile Transfer protocol used.
INT systemReset1.3.6.1.4.1.164.6.2.13INTEGERread-writeReset action to be performed on the system. - resetMapping - reset SDH/SONET mapping to default for all SDH/SONET links. - resetStandby(6) - can be used only by devices with redundancy on MAIN/CL.
systemTiming1.3.6.1.4.1.164.6.2.14
STR systemDate1.3.6.1.4.1.164.6.2.14.1DisplayStringread-writeSystem date.
STR systemTime1.3.6.1.4.1.164.6.2.14.2DisplayStringread-writeSystem time.
I32 systemTimeElapsed1.3.6.1.4.1.164.6.2.14.3Integer32read-onlyThe number of seconds that have elapsed since the beginning of the current error-measurement period. Same for all ports of the device.
systemNtp1.3.6.1.4.1.164.6.2.14.4
INT systemNtpMode1.3.6.1.4.1.164.6.2.14.4.1INTEGERread-writeThis variable represents the NTP Mode.
I32 systemNtpGmt1.3.6.1.4.1.164.6.2.14.4.2Integer32read-writeThis variable represents the NTP GMT (Greenwich Mean Time), Possible values range is -12..12. For new devices/versions this variable will be in minutes.
IPt systemNtpServerAddressType1.3.6.1.4.1.164.6.2.14.4.3InetAddressTyperead-writeThis variable represents the NTP Server Address Type.
IP systemNtpServerAddress1.3.6.1.4.1.164.6.2.14.4.4InetAddressread-writeThis variable represents the NTP Server Address.
U32 systemNtpUpdateInterval1.3.6.1.4.1.164.6.2.14.4.5Unsigned32read-writeThis variable represents the NTP Update Interval, measured in seconds.
INT systemNtpCmd1.3.6.1.4.1.164.6.2.14.4.6INTEGERread-writeThis variable represents NTP possible commands. After the Agent accepts a command, it will automatically change the value to off(2).
schedXTable1.3.6.1.4.1.164.6.2.14.5not-accessibleAn Augment to the Schedule table (schedTable in DISMAN-SCHEDULE-MIB; RFC-3231).
schedXEntry1.3.6.1.4.1.164.6.2.14.5.1not-accessibleAn entry in the table.
U32 schedYear1.3.6.1.4.1.164.6.2.14.5.1.1Unsigned32read-createThe year during which the scheduled action should take place.
INT schedWeekInMonth1.3.6.1.4.1.164.6.2.14.5.1.2INTEGERread-createThe week in month (schedMonth) during which the scheduled action should take place.
I32 schedParam1.3.6.1.4.1.164.6.2.14.5.1.3Integer32read-createA Parameter that might be used whenever the scheduled action takes place. For summer-time schedule - This variable represents the time offset (in minutes), meaning: the number of minutes that should be added for summer-time.
systemPort1.3.6.1.4.1.164.6.2.15
physicalConnectorTable1.3.6.1.4.1.164.6.2.15.1not-accessibleThis table includes the connector type of ports or interfaces.
physicalConnectorEntry1.3.6.1.4.1.164.6.2.15.1.1not-accessibleAn entry in table.
I32 portIdx1.3.6.1.4.1.164.6.2.15.1.1.1Integer32read-onlyThis object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
INT physicalConnector1.3.6.1.4.1.164.6.2.15.1.1.2INTEGERread-onlyThe connector of the port/interface. other - none of the specified connectors none - no connector.
INT portOptWaveLength1.3.6.1.4.1.164.6.2.15.1.1.3INTEGERread-onlyWave Length of an Optical interface/port in [nm] and specification if Laser or not. notApplicable - for non-optical ports.
INT portOptMode1.3.6.1.4.1.164.6.2.15.1.1.4INTEGERread-onlyLaser Mode of an Optical Laser interface/port. notApplicable - for non-Laser ports.
INT portBalance1.3.6.1.4.1.164.6.2.15.1.1.5INTEGERread-writeThis object is according to the port Impedance. For T1 - always balanced. For E1 - there are different impedance values for balanced and unbalanced.
INT portDdmSupport1.3.6.1.4.1.164.6.2.15.1.1.6INTEGERread-onlySFP (Small Form Pluggable) port -support Digital Diagnostics Monitoring.
STR portMfgName1.3.6.1.4.1.164.6.2.15.1.1.7SnmpAdminStringread-only(SFP) Port Manufacturer name (Maximum - 16 characters).
U32 portTypicalMaxRange1.3.6.1.4.1.164.6.2.15.1.1.8Unsigned32read-onlyMaximum range supported by SFP port, in meter units.
STR physicalConnectorString1.3.6.1.4.1.164.6.2.15.1.1.9SnmpAdminStringread-only(SFP) connector type. It can be Vendor Specific (unknown in advance). Being a string, the object is not affected by any future new connectors. This object will usually not be used for drawing the connector.
STR portVendorPartNo1.3.6.1.4.1.164.6.2.15.1.1.10SnmpAdminStringread-onlySFP Vendor Part Number. Being a string, the object is not affected by any future new SFPs.
prtSupervisory1.3.6.1.4.1.164.6.2.15.2
prtSpTable1.3.6.1.4.1.164.6.2.15.2.1not-accessibleA table.
prtSpEntry1.3.6.1.4.1.164.6.2.15.2.1.1not-accessibleSupervisory port parameter table.
I32 prtSupervisoryIndex1.3.6.1.4.1.164.6.2.15.2.1.1.1Integer32read-onlyThe SP port index. For some products, having modules (cards): The LS byte of the integer is the port index 1..255. The MS byte is different than 0 only if the port belongs to a module. In that case it is the module number. For other products' index see their specification.
INT prtSupervisoryRate1.3.6.1.4.1.164.6.2.15.2.1.1.2INTEGERread-writeThis attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent.
INT prtSupervisoryDataBits1.3.6.1.4.1.164.6.2.15.2.1.1.3INTEGERread-writeThis attribute indicates the number of data bits in an async frame
INT prtSupervisoryParity1.3.6.1.4.1.164.6.2.15.2.1.1.4INTEGERread-writeThis attribute indicates the parity mode in an async frame
INT prtSupervisoryStopBits1.3.6.1.4.1.164.6.2.15.2.1.1.5INTEGERread-writeThis attribute indicates the parity mode in an async frame.
INT prtSupervisoryUsage1.3.6.1.4.1.164.6.2.15.2.1.1.6INTEGERread-writeThis attribute indicates the usage of the SP port.
INT prtSupervisoryInterface1.3.6.1.4.1.164.6.2.15.2.1.1.7INTEGERread-writeThis attribute indicates the supervisory port interface.
INT prtSupervisoryCTS1.3.6.1.4.1.164.6.2.15.2.1.1.8INTEGERread-writeCTS line state.
INT prtSupervisoryDcdDelay1.3.6.1.4.1.164.6.2.15.2.1.1.9INTEGERread-writeDCD delay in msec.
INT prtSupervisoryDSR1.3.6.1.4.1.164.6.2.15.2.1.1.10INTEGERread-writeDSR line state.
INT prtSupervisoryRoutProtocol1.3.6.1.4.1.164.6.2.15.2.1.1.11INTEGERread-writeThis attribute indicates the routing protocol of the port. notApplicable - for DP.
prtPerformance1.3.6.1.4.1.164.6.2.15.3
prtPerfTable1.3.6.1.4.1.164.6.2.15.3.1not-accessibleThis table includes G.826 ports or interfaces.
prtPerfEntry1.3.6.1.4.1.164.6.2.15.3.1.1not-accessibleAn entry in table.
I32 prtPerfIdx1.3.6.1.4.1.164.6.2.15.3.1.1.1Integer32read-onlyThis object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
INT prtPerfPeriodRef1.3.6.1.4.1.164.6.2.15.3.1.1.2INTEGERread-onlyThis object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last prtPerfSaveAndResetCmd received or since Start-up (if no prtPerfSaveAndResetCmd was received since Start-up) until now. lastPeriod - the period between last two commands of prtPerfSaveAndResetCmd. - If only one command occured since Start-up: the period between Start-up and last command. - If no command occured since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
I32 prtPerfElapsedTime1.3.6.1.4.1.164.6.2.15.3.1.1.3Integer32read-onlyElapsed Time in seconds. - for prtPerfPeriodRef=currentPeriod: The period since last prtPerfSaveAndResetCmd received or since Start-up (if no prtPerfSaveAndResetCmd was received since Start-up) until now. - for prtPerfPeriodRef=lastPeriod: The value of prtPerfElapsedTime when last prtPerfSaveAndResetCmd was received.
I32 prtPerfUAS1.3.6.1.4.1.164.6.2.15.3.1.1.4Integer32read-onlyNumber of Unavailable Seconds for the reference period (prtPerfPeriodRef).
I32 prtPerfES1.3.6.1.4.1.164.6.2.15.3.1.1.5Integer32read-onlyNumber of Errored Seconds for the reference period (prtPerfPeriodRef).
I32 prtPerfSES1.3.6.1.4.1.164.6.2.15.3.1.1.6Integer32read-onlyNumber of Severely Errored Seconds for the reference period (prtPerfPeriodRef).
I32 prtPerfBBE1.3.6.1.4.1.164.6.2.15.3.1.1.7Integer32read-onlyNumber of Background Block (or Frame) Errors for the reference period (prtPerfPeriodRef).
I32 prtPerfBlocksPerSec1.3.6.1.4.1.164.6.2.15.3.1.1.8Integer32read-onlyBlocks per second (or frames per second) of the port/interface indicated by portIdx. This object is constant for a certain port/interface. It is not affected by the prtPerfPeriodRef index.
TIK prtPerfTimeTag1.3.6.1.4.1.164.6.2.15.3.1.1.9TimeTicksread-onlyTime Tag of Last Period: sysUpTime when last prtPerfSaveAndResetCmd was executed. This object is applicable only for prtPerfPeriodRef=lastPeriod. For prtPerfPeriodRef=currentPeriod, the value will always be 0.
INT prtPerfSaveAndResetCmd1.3.6.1.4.1.164.6.2.15.3.1.1.10INTEGERread-writeA command per port/interface, to Save data of Current Period in Last Period data-set and start a new counting period for Current Period. This object is applicable only for prtPerfPeriodRef=currentPeriod. Setting this object to on(3) for prtPerfPeriodRef=last, will cause the agent to return: Bad Value response. When setting validly this object to on(3), agent will perform the required command and will reset automatically the value of this object to off(2). Setting this object to off(2), will do nothing.
prtTest1.3.6.1.4.1.164.6.2.15.4
prtTestTable1.3.6.1.4.1.164.6.2.15.4.1not-accessibleThis table includes test data for ports or interfaces.
prtTestEntry1.3.6.1.4.1.164.6.2.15.4.1.1not-accessibleAn entry in table.
I32 prtTestIdx1.3.6.1.4.1.164.6.2.15.4.1.1.1Integer32read-onlyThis object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
I32 prtTestCmdAndStatus1.3.6.1.4.1.164.6.2.15.4.1.1.2Integer32read-writeSetting this object to a value as detailed further on (except 0) will initiate a test on the specific port. The test/s requested will be set according to the respective bit. The value of this object will be a sum of (2**n), where n is the Bit: TEST BIT VALUE ----------- --- ------ reserved 0 1 PayloadLoop=RLB 1 (=Remote Loopback) 2 LineLoop=DIG 2 (=Digital) 4 OtherLoop 3 8 InwardLoop=LLB 4 (=Local Loopback) 16 BERT 5 32 LC 6 64 ToneInjection 7 128 Inband 8 256 BERT Remote (or E1/T1 RLB) 9 512 Downstream-AIS (or E1/T1 LLB) 10 1024 Upstream-AIS 11 2048 Rem-Loop-on-Rem-Unit 12 4096 MacSwapLoop 13 8192 OamETHLoopback 14 16384 OamETHLinkTrace 15 32768 e.g : If the requested value is 20 -> 010100 -> Bits 2 & 4 are set -> the requested tests are : LineLoopback=DIG InwardLoopback=LLB Not all tests combinations are valid. For valid test combination, see each product's specification. For LRS52, only single test is allowed simultaneously The terminology and order of the first tests (except BERT) is according to the one used for Test Status of DS1 and DS3 standards. The notations : RLB, LLB, DIG are the most used in RAD's products, but they can be different. For exact definition see product's spec. Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port. When no test is running on the port, the Get value (test status) will be 0. PayloadLoop=RLB The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function. LineLoop=DIG The received signal at this interface does not go through the device (minimum penetration) but is looped back out. OtherLoop Loopbacks that are not defined here. InwardLoop=LLB The sent signal at this interface is looped back through the device. LC This loop is applicable only for HSSI interface, towards the router . ToneInjection This loop is applicable for analog voice (like FXS). Downstream-AIS E1 AIS signal (all ones) is transmitted in the relevant channel toward the STM-1 line. Upstream-AIS E1 AIS signal (all ones) is generated in the relevant channel toward the local received tributary channel output Rem-Loop-on-Rem-Unit Request from far end device to activate remote loopback towards near-end device MacSwapLoop This loop is applicable for ethernet port. Loop is implemented by swapping the MAC addresses of the incoming message. OamETHLoopback Ethernet Loopback is used to verify connectivity of a MEP with a MIP or peer MEP(s) (ITU-T Y.1731, Clause 7.2). OamETHLinkTrace Ethernet Link Trace is an on-demand OAM function which can be used for the two following purposes: - Adjacent Relation Retrieval - Fault Localization (ITU-T Y.1731, Clause 7.3).
I32 prtBertCounter1.3.6.1.4.1.164.6.2.15.4.1.1.3Integer32read-onlyThis object indicates the number of BERT errors encountered during the BERT operation. It is valid only when BERT (Bit Error Rate Test) is active on the specific port. The Counter starts from zero (0) anytime BERT is initiated.
INT prtTestInitiator1.3.6.1.4.1.164.6.2.15.4.1.1.4INTEGERread-onlyThis object indicates who initiated this port's test/s.
I32 prtTestTimeout1.3.6.1.4.1.164.6.2.15.4.1.1.5Integer32read-writeThis object is applicable only when a single test is running. It indicates the test activation timeout in minutes. For RICi-E1T1, RICi-E3T3 the measurement unit is in seconds. When the timeout expires, the test is stopped. Value of 0 indicates test may run Forever
INT prtTestVctRxResult1.3.6.1.4.1.164.6.2.15.4.1.1.6INTEGERread-onlyThis object indicates the result of the Vct on the cable connected to the RX connector.
INT prtTestVctTxResult1.3.6.1.4.1.164.6.2.15.4.1.1.7INTEGERread-onlyThis object indicates the result of the Vct on the cable connected to the TX connector.
I32 prtTestVctRxDistance1.3.6.1.4.1.164.6.2.15.4.1.1.8Integer32read-onlyThis object indicates the distance in Meters to the RX cable Open/ Short location discovered by the Vct. This parameter is applicable for Vct Result = Normal or Fail only, Else the value of this parameter will be equal to 0.
I32 prtTestVctTxDistance1.3.6.1.4.1.164.6.2.15.4.1.1.9Integer32read-onlyThis object indicates the distance in Meters to the TX cable Open/ Short location discovered by the Vct. This parameter is applicable for Vct Result = Normal or Fail only, Else the value of this parameter will be equal to 0.
INT prtTestVctCmd1.3.6.1.4.1.164.6.2.15.4.1.1.10INTEGERread-writeVct command. on (3) = Start Vct on both cables connected to RX and TX connectors of this port. Agent will perform the required command and change automatically the value of this object to off(2).
I32 prtTestVctRxCrossPair1.3.6.1.4.1.164.6.2.15.4.1.1.11Integer32read-onlyThis object should be equal to the Index (prtTestIdx) of the Rx cross pair. This object is applicable only for Vct Result = shortToCrossPair or coupleWithCrossPair. This object was especially created for ETX-202. Currently not in use.
I32 prtTestVctTxCrossPair1.3.6.1.4.1.164.6.2.15.4.1.1.12Integer32read-onlyThis object should be equal to the Index (prtTestIdx) of the Tx cross pair. This object is applicable only for Vct Result = shortToCrossPair or coupleWithCrossPair.
U32 prtTestActivationDelay1.3.6.1.4.1.164.6.2.15.4.1.1.13Unsigned32read-writeThis object is applicable only when a single test is running. It indicates test activation delay in seconds. A Value of 0 indicates that the test starts immediately.
INT prtTestMacSwapLoopDataMode1.3.6.1.4.1.164.6.2.15.4.1.1.14INTEGERread-writeThis object defines which part of the data will be looped back.
I32 prtTestMacSwapLoopVlanId1.3.6.1.4.1.164.6.2.15.4.1.1.15Integer32read-writeThis object specifies the VLAN ID for prtTestMacSwapLoopDataMode=specificVlan.
INT prtTestMacSwapLoopDirection1.3.6.1.4.1.164.6.2.15.4.1.1.16INTEGERread-writeThis object defines the direction of the performed loopback. In ETX102 'local' corresponds to Ingress loop (either on User port or on Network port), and 'remote' corresponds to Egress loop (either on User port or on Network port).
MAC prtTestMacSwapLoopDestAddr1.3.6.1.4.1.164.6.2.15.4.1.1.17MacAddressread-writeConfigures the MAC address that will be sent in the Destination field of the packet in the outgoing direction.
MAC prtTestMacSwapLoopSrcAddr1.3.6.1.4.1.164.6.2.15.4.1.1.18MacAddressread-writeConfigures the MAC address that will be sent in the Source field of the packet in the outgoing direction.
U32 prtTestOamMinRoundTripDelay1.3.6.1.4.1.164.6.2.15.4.1.1.19Unsigned32read-onlyThe mininal value of round trip delay of loopback message for a session of OAM loopback.Units are msec.
U32 prtTestOamMaxRoundTripDelay1.3.6.1.4.1.164.6.2.15.4.1.1.20Unsigned32read-onlyThe maximum value of round trip delay of loopback message for a session of OAM loopback.Units are msec.
U32 prtTestOamAvgRoundTripDelay1.3.6.1.4.1.164.6.2.15.4.1.1.21Unsigned32read-onlyThe average round trip delay of loopback message for a session of OAM loopback.Units are msec.
U32 prtTestOamTxInterval1.3.6.1.4.1.164.6.2.15.4.1.1.22Unsigned32read-writeIndicates the interval between loopback sent messages.Units are msec.
IP prtTestDestinationIpAddress1.3.6.1.4.1.164.6.2.15.4.1.1.23IpAddressread-writeIndicates the destination IP Address in the transmitted messages that are looped back.
U32 prtTestTTL1.3.6.1.4.1.164.6.2.15.4.1.1.24Unsigned32read-writeTime-to-live.Number of hops the loopback message will go through the net before deciding to discard it.
U32 prtTestBwProfile1.3.6.1.4.1.164.6.2.15.4.1.1.25Unsigned32read-writeIndicates the BW profile (from bwProfileTable) that is assigned to the loopback test in order to limit the traffic that is looped back.
prtParam1.3.6.1.4.1.164.6.2.15.5
prtParamTable1.3.6.1.4.1.164.6.2.15.5.1not-accessibleThis table includes general port parameters. The meaning is different for every product that supports it due to a general parameter - prtControlCnfg. For ACE2002: -This table is used as a mechanism to create the next interface index. The algorithm description: The NMS will send the agent the following get command: get(nextIfIndex.index), where index=interface on which the new index is dependent on. Upon this command the agent will generate and return the new index to the NMS. - This table is partially supported according to the interface type. Upon getNext function the irrelevant parameters will be skipped.
prtParamEntry1.3.6.1.4.1.164.6.2.15.5.1.1not-accessibleAn entry in table.
I32 prtParamIdx1.3.6.1.4.1.164.6.2.15.5.1.1.1Integer32read-onlyThis object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used. For ACE2002: This parameter is the physical layer ifIndex of the slot on which the NMS requires the next interface index.
I32 prtControlCnfg1.3.6.1.4.1.164.6.2.15.5.1.1.2Integer32read-writeThis object may be used for port RW general parameter/s. For detailed meaning, see product's spec. Supported by: PRBi-E3/T3. For ACE2002: This parameter will include the value of the new index generated by agent. For Optimux-T3 and OP-155-1: This parameter will be used for Release Remote LLB Command: on=2= Set value only. Command to release LLB of Remote Unit. Agent will return automatically to 'off' value after performing the command. off=3=Get value only. For LA140 This parameter will be used as EchoCanceler per timeslot off = 2 Echo Canceler is disabled on = 3 Echo Canceler is enabled For FCD-155 This parameter will be used to select the port that is clock source for a PDH port, For E1/T1 PDH VC12/VT1.5 = 2 SDH/SONET = 3 For E3/T3 PDH VC3/DS3 = 2 SDH/SONET = 3 For ACE-52 This parameter will be used as Transmit Frame Type, i.e. which type of frame the corresponding bridge port will transmit: Untagged = 2 Tagged = 3 .
INT prtParamClkSrc1.3.6.1.4.1.164.6.2.15.5.1.1.3INTEGERread-writeThe source of Transmit Clock. 'loopTiming' or 'loopback' indicates that the recovered receive clock is used as the transmit clock. 'localTiming' or 'internal' indicates that a local clock source is used or when an external clock is attached to the box containing the interface. 'throughTiming' or 'external' indicates that recovered receive clock from another card or interface is used as the transmit clock. 'adaptive' indicates that the clock is recovered according to the received data flow rate. 'master' and 'fallback' values may be used RO to indicate active clock. 'station' - indicate clock received from station port is used as transmit clock.
INT prtParamPhantom1.3.6.1.4.1.164.6.2.15.5.1.1.4INTEGERread-writePower feeding to another device.
INT prtParamResetStatsCmd1.3.6.1.4.1.164.6.2.15.5.1.1.5INTEGERread-writeReset statistics of the selected port.
TIM prtParamLastResetStatsTime1.3.6.1.4.1.164.6.2.15.5.1.1.6TimeStampread-onlyThe value of MIB II's sysUpTime object at the last time that prtParamResetStatsCmd was Set to on(3) for this port. If prtParamResetStatsCmd was never Set to on(3) since last re-initialization of the agent, then this object contains a zero value. This object enables calculating the running time of Statistics counters for this port, by: [sysUpTime-prtParamLastResetStatsTime]. For some devices other types of 'Reset' may affect this parameter
INT prtParamInterfaceType1.3.6.1.4.1.164.6.2.15.5.1.1.7INTEGERread-writeThe type of the port.
INT prtParamClearAlarm1.3.6.1.4.1.164.6.2.15.5.1.1.8INTEGERread-writeSetting this attribute to ON, will enforce a clear operation on the Port Alarms. Upon completion, the value will automatically change to off(2).
OCT prtParamLeds1.3.6.1.4.1.164.6.2.15.5.1.1.9OCTET STRINGread-onlyThis entry specifies the LEDs status of the port. Each led is represented by 4 bits where the first 2 bits (left) specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY). The order of the LEDS is from top to bottom, left to right: For each row starting from the top, the LEDS are returned from left to right.
INT prtParamLineLength1.3.6.1.4.1.164.6.2.15.5.1.1.10INTEGERread-writeLine Length of the line connected to this port.
INT prtParamUsage1.3.6.1.4.1.164.6.2.15.5.1.1.11INTEGERread-writeDefines whether this port works as User port or as Network port.
INT prtParamMappingMode1.3.6.1.4.1.164.6.2.15.5.1.1.12INTEGERread-writeThis object defines path protection on SONET/SDH link Auto - SONET/SDH mapping for port is copied automatically to same TU on the redundant SONET/SDH local (reside on same slot) link by agent. Manual - the user can configure the redundant mapping for port on the same link or to the other link on any TU Adjacent - similar to auto, but mapping is copied automatically by agent to link on adjacent slot .
INT prtParamAlarmIndication1.3.6.1.4.1.164.6.2.15.5.1.1.13INTEGERread-onlyThis object indicates status-aggregation of non-masked alarms associated with all interface layers, related to this physical port. When at least one non-masked alarm exists on any layer, value of this object is on (3). Indication will be off (2) only when there's no active non-masked alarm on any interface layer related to this port. Masking an Alarm, will consider it as not exist for this indication. Example: When a port has an ATM higher layer and at least one VC has alarm, value of this object will be on (3)
OCT prtParamClkQualityLevel1.3.6.1.4.1.164.6.2.15.5.1.1.14OCTET STRINGread-onlyThis parameter indicates quality level of clock signal. Quality is encoded according to SSM (Synchronization Status Messages) encoding. Bits 8 -5 of byte are encoded as follows (when bit1=0): Left most bit - MSB(8) ---> LSB(5) 8765 0000 Quality Unknown 0010 PRC (Primary Reference Clock) - Rec. G.811 0100 SSU-T (Sync. Source Unit-Transit)- Rec. G.812 Transit 1000 SSU-L (Sync. Source Unit Local) - Rec. G.812 Local 1011 SEC (SDH Equipment Clock) 1111 DNU (do not use for synchronization) 0001 PRS (=ST1 = Stratum 1 Traceable) 0111 ST2 (Stratum 2 Traceable) 1010 ST3 (Stratum 3 Traceable) 1100 SMC (SONET Minimum Clock Traceable) 1101 Stratum 3E Traceable bit1 = '1' - indicates all octet is Not Applicable
INT prtParamClkWaveShape1.3.6.1.4.1.164.6.2.15.5.1.1.15INTEGERread-writeWave shape of station clock source signal.
INT prtParamStatus1.3.6.1.4.1.164.6.2.15.5.1.1.16INTEGERread-onlyStation clock source Status.
I32 prtParamSignalLevel1.3.6.1.4.1.164.6.2.15.5.1.1.17Integer32read-onlyThis object indicates signal level (in thenth of dB units) on selected port.
OCT prtParamClkUserQualityLevel1.3.6.1.4.1.164.6.2.15.5.1.1.18OCTET STRINGread-writeThis parameter allows user to mark quality level of clock. Quality is encoded according to SSM (Synchronization Status Messages) encoding. Bits 8 -5 of byte are encoded as follows: Left most bit - MSB(8) ---> LSB(5) 8765 0000 Quality Unknown 0010 PRC (Primary Reference Clock) - Rec. G.811 0100 SSU-T (Sync. Source Unit-Transit) Rec. G.812 Transit 1000 SSU-L (Sync. Source Unit Local) - Rec. G.812 Local 1011 SEC (SDH Equipment Clock) 1111 DNU (do not use for synchronization)
U32 prtParamDataRate1.3.6.1.4.1.164.6.2.15.5.1.1.19Unsigned32read-writeRate of serial data port (V.11, V.24, V.35) in kbps units.
INT prtParamLoopDetect1.3.6.1.4.1.164.6.2.15.5.1.1.20INTEGERread-writeEnable/disable Loop Detection on a port. Examples of ports: physical, Channelized Bundle over TDM Uplink, Bridge Ports.
OCT prtParamActUponLoopDetect1.3.6.1.4.1.164.6.2.15.5.1.1.21OCTET STRINGread-writeThis parameter is used to indicate which actions should be taken in case a loop is detected in the network the port is part of. Each action is represented by a bit. Currently defined (for RIC155GE/RIC622GE): Bit 0 - Transmit Shut Down Bit 1 - Forward Alarms If bit value = '1' then the action is taken. If bit value = '0' then the actions is not taken.
INT prtParamPSNLayer1.3.6.1.4.1.164.6.2.15.5.1.1.22INTEGERread-writeThis object indicates the network layer from which clock is derived.
INT prtParamRxSsm1.3.6.1.4.1.164.6.2.15.5.1.1.23INTEGERread-writeThis object indicates if Station Clock SSM messages received will serve as criteria for clock selection.
INT prtParamClkSsmRxSource1.3.6.1.4.1.164.6.2.15.5.1.1.24INTEGERread-writeThis object indicates the Sa-bit of the E1 frame, in which SSM messages are carried.
U32 prtParamFarEndDevice1.3.6.1.4.1.164.6.2.15.5.1.1.26Unsigned32read-writeProgrammed Far-End device connected to this port. This object is relevant for products having multiple DBs. It will enable configuring offline, the relevant data. For MP-4100, LRS-102 OP-108/106 cards, the options will be: 1 = None (when a port is not connected to any remote device) 2 = OP-108 3 = OP-108/ETH 4 = OP-106 5 = OP-106/ETH 6 = card of MP or LRS-102
INT prtParamTxClk1.3.6.1.4.1.164.6.2.15.5.1.1.27INTEGERread-writeenable/disable station clock signal output.
prtIP1.3.6.1.4.1.164.6.2.15.6
prtIpParamTable1.3.6.1.4.1.164.6.2.15.6.1not-accessibleA table - Parameters for IP Ports.
prtIpParamEntry1.3.6.1.4.1.164.6.2.15.6.1.1not-accessibleAn entry in table.
I32 prtIpParamConfigIdx1.3.6.1.4.1.164.6.2.15.6.1.1.1Integer32read-onlyThis object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). For products having Agent and Edit configurations, Write operation for the table entries is allowed only to Config=255.
I32 prtIpParamSlotIdx1.3.6.1.4.1.164.6.2.15.6.1.1.2Integer32read-onlyThis object indicates a unique number of the slot position in which the module is inserted. notApplicable = 255 (for products that don't have slots). For KM: kmxMlA (103), kmxMlB (104).
I32 prtIpParamIdx1.3.6.1.4.1.164.6.2.15.6.1.1.3Integer32read-onlyThis object indicates a unique Port Index.
IP prtIpParamHostIP1.3.6.1.4.1.164.6.2.15.6.1.1.4IpAddressread-writeThe host interface IP address.
IP prtIpParamHostMask1.3.6.1.4.1.164.6.2.15.6.1.1.5IpAddressread-writeThe host interface subnet mask.
IP prtIpParamDefaultGateway1.3.6.1.4.1.164.6.2.15.6.1.1.6IpAddressread-writeDefault Gateway's IP Address.
INT prtIpParamMediaMode1.3.6.1.4.1.164.6.2.15.6.1.1.7INTEGERread-onlyThis object indicates the real Media Mode.
INT prtIpParamMediaRate1.3.6.1.4.1.164.6.2.15.6.1.1.8INTEGERread-onlyThis object indicates the real Media Rate (Mbps).
INT prtIpParamMngVlanSupport1.3.6.1.4.1.164.6.2.15.6.1.1.9INTEGERread-writeManagement VLAN support (Tagging). no - No support of VLAN Tagging. yes - 4 VLAN bytes will be added to the frame.
I32 prtIpParamMngVlanId1.3.6.1.4.1.164.6.2.15.6.1.1.10Integer32read-writeManagement VLAN ID.
I32 prtIpParamMngVlanPriority1.3.6.1.4.1.164.6.2.15.6.1.1.11Integer32read-writeManagement VLAN Frame priority.
INT prtIpParamRingMode1.3.6.1.4.1.164.6.2.15.6.1.1.12INTEGERread-writeThis object indicates If Ring Mode is enabled or not.
INT prtIpParamProtIpEnable1.3.6.1.4.1.164.6.2.15.6.1.1.13INTEGERread-writeThis object indicates whether a list of Protected IP Addresses is enabled or not. This object is applicable only if prtIpParamRingMode=enable.
INT prtIpParamTrafficPriority1.3.6.1.4.1.164.6.2.15.6.1.1.14INTEGERread-writeThis object indicates the traffic priority of this port.
IP prtIpParamRemoteIP1.3.6.1.4.1.164.6.2.15.6.1.1.15IpAddressread-writeThis is the IP Address of the remote device that is connected to the current device (Point to Point Application). It is used for sending OAM packets on the LAN to the remote side in order to check that the connection is OK.
INT prtIpParamMaxTxBandwidth1.3.6.1.4.1.164.6.2.15.6.1.1.16INTEGERread-writeThis object shows the Max Bandwidth allowed on the LAN. Full - means that a Maximum of 100 Mega Byte Rate may go through the LAN. e1(3) means that the maximum is an E1 rate. t1(4) is for a maximum of a T1 rate.
I32 prtIpParamTos1.3.6.1.4.1.164.6.2.15.6.1.1.17Integer32read-writeTOS = Type of Service transmitted. Valid values: 0..255.
INT prtIpParamConnect1.3.6.1.4.1.164.6.2.15.6.1.1.18INTEGERread-writePort Connection.
I32 prtIpParamAgingTime1.3.6.1.4.1.164.6.2.15.6.1.1.19Integer32read-writeAging Time in seconds.
INT prtIpParamEncapsulationProt1.3.6.1.4.1.164.6.2.15.6.1.1.20INTEGERread-writeEncapsulation Protocol.
I32 prtIpParamEncapProtPort1.3.6.1.4.1.164.6.2.15.6.1.1.21Integer32read-writeEncapsulation Protocol Port (TCP/UDP Port).
INT prtIpParamVlanSupport1.3.6.1.4.1.164.6.2.15.6.1.1.22INTEGERread-writeVLAN support (Tagging). 'no' - No support of VLAN Tagging. 'yes' - 4 VLAN bytes will be added to the frame.
I32 prtIpParamVlanId1.3.6.1.4.1.164.6.2.15.6.1.1.23Integer32read-writeVLAN Identifier.
I32 prtIpParamVlanPriority1.3.6.1.4.1.164.6.2.15.6.1.1.24Integer32read-writeVLAN Frame priority.
I32 prtIpParamDoubleTagVlanId1.3.6.1.4.1.164.6.2.15.6.1.1.25Integer32read-writeVLAN Identifier of the Double Tagging VLAN.
I32 prtIpParamDoubleTagVlanPriority1.3.6.1.4.1.164.6.2.15.6.1.1.26Integer32read-writeVLAN Frame priority of the Double Tagging VLAN.
INT prtIpParamVlanTagging1.3.6.1.4.1.164.6.2.15.6.1.1.27INTEGERread-writeVLAN Tagging. 'unmodified' - No change will be done to the Frame. 'tag' - Add Tag to Untagged Frames. 'doubleTag' - Add Tag to all Frames. 'doubleTagAndFallBack' - Double Tagging will have different rules for VLANs that this port is member in, than these it is not a member in. 'untag' - Remove Tag from tagged frames.
I32 prtIpParamRateLimit1.3.6.1.4.1.164.6.2.15.6.1.1.28Integer32read-writeThe maximum rate permitted to transfer via this port, in Kbps.
I32 prtIpParamDefInterface1.3.6.1.4.1.164.6.2.15.6.1.1.29Integer32read-writeThe Default Interface for packets with unresolved destination subnet. For internal-X port: 100 + X .
INT prtIpParamMng1.3.6.1.4.1.164.6.2.15.6.1.1.30INTEGERread-writeThis object indicates whether Management is enabled/disabled via this port.
I32 prtIpParamFloodedRateLimit1.3.6.1.4.1.164.6.2.15.6.1.1.31Integer32read-writeThe maximum rate permitted to transfer broadcast, multicast, and unicast flooded frames via this port, in Kbps. 0 - Disable. In Ipmux14 this parameter is applicable when prtIpParamRateLimit=0 (disable).
U32 prtIpParamBurstSize1.3.6.1.4.1.164.6.2.15.6.1.1.32Unsigned32read-writeThe burst size that the port can support beyond rate limitation determined in prtIpParamRateLimit. Burst Size is measured in bytes.
INT prtIpParamLimitPacketType1.3.6.1.4.1.164.6.2.15.6.1.1.33INTEGERread-writeThe packet type that will be rate limited. Rate limitation determined in prtIpParamRateLimit. all - All packet types are rate limited. broadMultiFloodedUnicast - Broadcast, Multicast and Flooded Unicast packets are rate limited. broadcastMulticast - Broadcast and Multicast packets are rate limited. broadcast - Broadcast packets are rate limited.
I32 prtIpParamKeepAliveInterval1.3.6.1.4.1.164.6.2.15.6.1.1.34Integer32read-writeThis parameter indicates the period of time (in msec.) between two consequent Keep Alive messages.
I32 prtIpParamKeepAliveThresh1.3.6.1.4.1.164.6.2.15.6.1.1.35Integer32read-writeThis parameter indicates the maximum number of missed Keep Alive answer messages acceptable, after which link status will be failed.
I32 prtIpParamP2pKeepAliveVlanId1.3.6.1.4.1.164.6.2.15.6.1.1.36Integer32read-writeDedicated VLAN ID for keep alive messages.
I32 prtIpParamP2pKeepAliveVlanPrio1.3.6.1.4.1.164.6.2.15.6.1.1.37Integer32read-writeVLAN priority for P2P keep alive messages .
MAC prtIpParamRingAdjacentMacAddr1.3.6.1.4.1.164.6.2.15.6.1.1.38MacAddressread-onlyThe MAC address of the adjacent NE connected to this port in an ETH ring. If the port is not a member of a ring, the value of this parameter will be 00-00-00-00-00-00.
prtClkSrc1.3.6.1.4.1.164.6.2.15.7
prtClkSrcTable1.3.6.1.4.1.164.6.2.15.7.1not-accessibleA table - Parameters for master and fallback clock source of ports .
prtClkSrcEntry1.3.6.1.4.1.164.6.2.15.7.1.1not-accessibleAn entry in table.
I32 prtClkSrcCnfgIdx1.3.6.1.4.1.164.6.2.15.7.1.1.1Integer32not-accessibleThis attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
I32 prtClkSrcPrtIdx1.3.6.1.4.1.164.6.2.15.7.1.1.2Integer32not-accessibleThis object indicates a unique Port Index (receiving clock). Refer to device specification for port Index
INT prtClkSrcIdx1.3.6.1.4.1.164.6.2.15.7.1.1.3INTEGERnot-accessibleAn index in the table. master - refers Master clock parameters fallback - refers Fallback clock parameters
INT prtClkSrcMode1.3.6.1.4.1.164.6.2.15.7.1.1.4INTEGERread-writeThis entry indicates the source the nodal timing is locked to.
I32 prtClkSrcPrt1.3.6.1.4.1.164.6.2.15.7.1.1.5Integer32read-writeThis entry is valid only when working in rxClk mode. It specifies the port from which the clock willl be taken. Refer to device specification for source port Index
opticalPort1.3.6.1.4.1.164.6.2.15.8
optPrtMonitorTable1.3.6.1.4.1.164.6.2.15.8.1not-accessibleA table - optical port (e.g SFP) monitoring parameters, according to SFF-8472 Specification for Diagnostic Monitoring Interface for Optical Xcvrs. and ITU-T rec. G.958
optPrtMonitorEntry1.3.6.1.4.1.164.6.2.15.8.1.1not-accessibleAn entry in table.
I32 optPrtMonitorPrtIdx1.3.6.1.4.1.164.6.2.15.8.1.1.1Integer32not-accessibleThis object indicates a unique (optical) Port Index . Refer to device specification for port Index.
INT optPrtMonitorSample1.3.6.1.4.1.164.6.2.15.8.1.1.2INTEGERnot-accessibleThis index indicates historic and current values - minimum, maximum and actual (current) value.
I32 optPrtMonitorTxPower1.3.6.1.4.1.164.6.2.15.8.1.1.3Integer32read-onlyTransmitted optical power level. Value is given in units of hundredth (1/100) of dBm.
I32 optPrtMonitorLaserBias1.3.6.1.4.1.164.6.2.15.8.1.1.4Integer32read-onlyLASER bias current level. Value is given in units of microAmper (uA).
I32 optPrtMonitorLaserTemp1.3.6.1.4.1.164.6.2.15.8.1.1.5Integer32read-onlyLASER temperature level, in hundredth (1/100) (C) degrees.
I32 optPrtMonitorRxPower1.3.6.1.4.1.164.6.2.15.8.1.1.6Integer32read-onlyReceived optical power in units of hundredth (1/100) of dBm.
I32 optPrtMonitorSupplyVoltage1.3.6.1.4.1.164.6.2.15.8.1.1.7Integer32read-onlySupply voltage, in hundredth (1/100) of volts (V).
optPrtCnfgTable1.3.6.1.4.1.164.6.2.15.8.2not-accessibleA table - optical port configuration
optPrtCnfgEntry1.3.6.1.4.1.164.6.2.15.8.2.1not-accessibleAn entry in table.
U32 optPrtCnfgIdx1.3.6.1.4.1.164.6.2.15.8.2.1.1Unsigned32not-accessibleThis attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.x.
U32 optPrtCnfgPrtIdx1.3.6.1.4.1.164.6.2.15.8.2.1.2Unsigned32not-accessibleThis object indicates a unique (optical) Port Index . Refer to device specification for port Index.
INT optPrtCnfgALS1.3.6.1.4.1.164.6.2.15.8.2.1.3INTEGERread-writeenable/disable Automatic Laser Shutdown
INT systemResetAllStatsCmd1.3.6.1.4.1.164.6.2.16INTEGERread-writeReset statistics of all ports and connections of the device.
INT systemClearTablesCmd1.3.6.1.4.1.164.6.2.17INTEGERread-writetempCnfgTables - Set *RowStatus = destroy for all entries of some tables having *RowStatus object, for temporary configuration only! (255). For the relevant tables, see product's specification. This object should be used by WAN product applications before performing the Update operation, in order to clear old entries of these tables. For MP-104/204 the entries will be destroyed for cnfg=1. off - agent will automatically change to this value, after performing the command.
I32 systemParameter1.3.6.1.4.1.164.6.2.18Integer32read-writeThis parameter can be used for different purposes: - TELNET session time-out in seconds. - Ace20: when trying to create row in a table that already has row with the same values, if set of values has to be unique in table, this attribute is set to the index of the existing row. - Optimux-T3: when CH interfaces are RJ-45, user can select via this object, the interface type for each Group of channels: T1 or E1: The selection will be a sum of the following Bits. '0' = T1 '1' = E1 Bit Group Value for each Bit having '1' 1 1 (CH-1..CH-8) 1 2 2 (CH-9..CH-12) 2 3 3 (CH-13..CH-20) 4 4 4 (CH-21..CH-28) 8 Examples: 15 = all Groups are selected to be E1 6 = Group 2 and Group 3 are selected to be E1 (Group 1 and Group 4 are T1). - FCD-A, FCD-M: user can select via this object the configuration used for Get values of MSDSL parameters that don't have configuration index. 1 =active configuration 255=temporary configuration. Set of this object should be done before Getting the MSDSL RW parameters. - Ace2002: This parameter indicates the number of intervals that were successfully uploaded upon statistics collection session. - FCD-IP, WR, FCD-IPD, LA-240: This parameter indicates whether Telnet Access is enabled/disabled: Values: 2 - Telnet Access is Disabled. 3 - Telnet Access is Enabled. -Vmux-110: This parameter value equals to maximum number of bundles. -Optimux-155: Simmilar usage to Optimux T3. user can select via this object, interface type T1 or E1 for each Group of channels (LIU): LIU group consists of 7 channels. Up to 12 LIUs are represented (84 T1 Channels). The selection will be a sum of the 2**n For each bit:'0' = T1 ,'1' = E1 Bit Group 1 1 (CH-1 .. CH-7) 2 2 (CH-8 .. CH-14) 3 3 (CH-15 ..CH-21) ... 9 9 (CH-56.. CH-63) ... 10 10 (CH-64..CH-70) 11 11 (CH-71..CH-77) 12 12 (CH-78..CH-84)
OCT agnGlobalAlarmMask1.3.6.1.4.1.164.6.2.19OCTET STRINGread-writeThe value of this attribute determines the alarm traps the agent should mask and not send to the managers. Each bit from a certain octet represents a certain alarm.
INT alarmSeverity1.3.6.1.4.1.164.6.2.20INTEGERread-onlyThis object specifies the severity of the alarms.
INT alarmState1.3.6.1.4.1.164.6.2.21INTEGERread-only.
INT agnTestStatus1.3.6.1.4.1.164.6.2.22INTEGERread-onlyIndicates the current test status (for all levels: system, card, port). This attribute will be set to: on(3): when there is at least one test in progress on the system/card/port off(2): when there is NO test in progress on the system/card/port
INT systemSaveAndResetAllStatsCmd1.3.6.1.4.1.164.6.2.23INTEGERread-writeon - a command to Save data of Current Period in Last Period data-set and start a new counting period for Current Period. off - agent will automatically change to this value, after performing the command.
IP systemDefaultGateway1.3.6.1.4.1.164.6.2.24IpAddressread-writeDefault Gateway's IP Address.
systemPsTable1.3.6.1.4.1.164.6.2.25not-accessibleThis table describes the PS types of a device. Usage of this table is specified in the device's NMS SRS
systemPsEntry1.3.6.1.4.1.164.6.2.25.1not-accessibleAn entry in table.
I32 systemPsIndex11.3.6.1.4.1.164.6.2.25.1.1Integer32read-onlyFirst Index. In HUBs: 1 = PS-A slot 2 = PS-B slot 3 = PS-C slot. In SA units: 1 = PS1 2 = PS2 Default = 1
I32 systemPsIndex21.3.6.1.4.1.164.6.2.25.1.2Integer32read-onlySecond Index. In HUBs: 1 always. In SA units: 1 = Local 2 = Remote Default = 1.
INT systemPsType1.3.6.1.4.1.164.6.2.25.1.3INTEGERread-onlyThe type of PS, for a stand-alone product. acDc - PS that supports both AC and DC. acPF - Power Feeding (phantom) box that is feeding another box by external AC. dcPF - Power Feeding (phantom) box that is feeding another box by external DC.
INT systemPsStatus1.3.6.1.4.1.164.6.2.25.1.4INTEGERread-onlyThe Status of the PS unit.
INT systemPsHotSwap1.3.6.1.4.1.164.6.2.25.1.5INTEGERread-onlyIs PS unit hot swap or fixed.
OCT agnFans1.3.6.1.4.1.164.6.2.26OCTET STRINGread-onlyThis entry specifies the FANs existence and status. Each fan will be represented by 2 bits, where the first bit (right) will specify the existence: (0= Not exist, 1=exist), and the left bit will specify it's status (0= OK, 1=FAIL), so for each fan: 00 - FAN does not exist 01 - FAN exists and OK (Low Mode) 10 - High Mode (FAN OK) 11 - FAN exists and is Failed bits 0-1 are for first fan bits 2-3 are for 2nd fan (if exists) bits 4-5 are for 3nd fan (if exists) bits 6-7 are for 4nd fan (if exists) bits 8-9 are for 5nd fan (if exists) bits 10-11 are for 6nd fan (if exists) bits 12-13 are for 7nd fan (if exists) bits 14-15 are for 8nd fan (if exists).
I32 agnSendTrapParameter1.3.6.1.4.1.164.6.2.27Integer32read-writeThis object specifies if the agent will attach a specific parameter to a trap. For ACE2002 the agent will attach or not the openViewSeverity parameter according to the value of this parameter: 1 - will attach openViewSeverity. 0 - will not attach openViewSeverity.
OCT agnSensorsStatus1.3.6.1.4.1.164.6.2.28OCTET STRINGread-onlyThis entry specifies the Sensors (Temperature sensors or others) existence and status. Each sensor will be represented by 2 bits, where the first bit (right) will specify the existence: (0= Not exist, 1=exist), and the left bit will specify it's status (0= OK, 1=FAIL), so for each sensor: 00 - sensor does not exist 01 - sensor exists and status is OK 11 - sensor exists and status is not OK ( e.g. temperature exceeds pre-defined threshold) bits 0-1 are for first sensor bits 2-3 are for 2nd sensor (if exists) and so on... Bit 0 is the LSB.
INT agnStationClockCard1.3.6.1.4.1.164.6.2.29INTEGERread-onlyThis entry specifies the station clock card existence and status. notExist - station clock card (piggy) does not exist. notValid - station clock card exists but clock status is not valid. ok - station clock card exists, and its status is OK When the sepcific reason for clock status not being valid is known, it may be reported by lossOfSync or lossOfSignal values.
I32 xcIndexNext1.3.6.1.4.1.164.6.2.30Integer32read-onlyThis object contains an appropriate value to be used for xcIndex when creating entries in the xcTable. The value 0 indicates that no unassigned entries are available. To obtain the xcIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index. After a manager retrieves a value the agent will determine through its local policy when this index value will be made available for reuse.
xcTable1.3.6.1.4.1.164.6.2.31not-accessibleConfiguration of system cross-connect entries. The table follows the behavior described in RFC 2515, RFC 1604 regarding the creation deletion and modification of an entry within the table.
xcEntry1.3.6.1.4.1.164.6.2.31.1not-accessibleAn entry in table.
I32 xcIndex1.3.6.1.4.1.164.6.2.31.1.1Integer32not-accessibleCross Connect Identifier.
I32 xcIfIndex11.3.6.1.4.1.164.6.2.31.1.2Integer32not-accessibleThe interface Index from the ifTable, which identify one side of the connection.
I32 xcVpi1.3.6.1.4.1.164.6.2.31.1.3Integer32not-accessibleThe VPI value.
I32 xcVci1.3.6.1.4.1.164.6.2.31.1.4Integer32not-accessibleThe VCI value.
I32 xcIfIndex21.3.6.1.4.1.164.6.2.31.1.5Integer32not-accessibleThe interface Index from the ifTable, which identifies the other side of the connection.
ROW xcRowStatus1.3.6.1.4.1.164.6.2.31.1.6RowStatusread-createThis parameter allows NMS to create/delete entries of this table.
STR xcDescr1.3.6.1.4.1.164.6.2.31.1.7DisplayStringread-createA textual string containing information about the xc entry.
INT xcAdminStatus1.3.6.1.4.1.164.6.2.31.1.8INTEGERread-createThe desired administrative status of this bi-directional cross-connect.
INT xcOperStatus1.3.6.1.4.1.164.6.2.31.1.9INTEGERread-onlyThe operational status of this bi-directional cross-connect.
INT xcAttachedIfType1.3.6.1.4.1.164.6.2.31.1.10INTEGERread-onlyThis object indicates if the specific VCC is already attached to any interface, and indicates the type of the interface. This object's purpose is to ease the checking to the NMS. notApplicable - used for entries that are not LAN (as HDLC), or when the VCC was attached to a bridge, or when this parameter is irrelevant. free - the LAN VCC wasn't attached yet to any router interface. routerAtm - attached to an ATM router interface. lis - attached to a LIS interface.
I32 xcInputPriority1.3.6.1.4.1.164.6.2.31.1.11Integer32read-createThis object is the priority, by which the LAN frames will be internaly sent to the ATM HW. This parameter is applicable if atmNteMdlInputPriorityMechanism=enabled. 1 - Highest priority. Will be the first to be sent to the ATM HW. 4 - Lowest priority. Will be the last to be sent to the ATM HW.
I32 xcBitMapping1.3.6.1.4.1.164.6.2.31.1.12Integer32read-onlyThis object maps this entry to a bit of an octet string. For ACE2002 this object maps the LAN VCC to the bit of the VLAN Port Lists. If the value is '0' then it means that this VCC is not mapped to a port list or it may be an HDSL entry.
systemModule1.3.6.1.4.1.164.6.2.32
modlParam1.3.6.1.4.1.164.6.2.32.1
modlParamTable1.3.6.1.4.1.164.6.2.32.1.1not-accessibleThis table include parameters for system modules.
modlParamEntry1.3.6.1.4.1.164.6.2.32.1.1.1not-accessibleAn entry in table.
I32 modlParamIndex1.3.6.1.4.1.164.6.2.32.1.1.1.1Integer32read-onlyThe module index. The index can be the slot number or any other module index as described in the specifications of the device. For Vmux-2100 device, the index will have values of: 1..4 for slots 1..4.
INT modlParamReset1.3.6.1.4.1.164.6.2.32.1.1.1.2INTEGERread-writeReset action to be performed on the module. Set the parameter will be done always to on(3) or factory (4). After performing the Reset operation, Agent will automatically set the parameter to off(2).
INT modlParamSwdlStatus1.3.6.1.4.1.164.6.2.32.1.1.1.3INTEGERread-onlyThis parameter indicates whatever the swdl is in process or not.
OCT modlParamLeds1.3.6.1.4.1.164.6.2.32.1.1.1.4OCTET STRINGread-onlyThis entry specifies the LEDs status of the module. Each led is represented by 4 bits where the first 2 bits (left) specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY). The order of the LEDS is from top to bottom, left to right: For each row starting from the top, the LEDS are returned from left to right.
INT modlParamType1.3.6.1.4.1.164.6.2.32.1.1.1.5INTEGERread-onlyThis attribute indicates the Module Type.
STR modlParamSwVer1.3.6.1.4.1.164.6.2.32.1.1.1.6DisplayStringread-onlyThis attribute indicates the Module's Software Version.
INT agnNearFarConnection1.3.6.1.4.1.164.6.2.33INTEGERread-onlyThis parameter describes the connection between near-end and far-end agents.
agnAccess1.3.6.1.4.1.164.6.2.34
INT agnTelnetAccess1.3.6.1.4.1.164.6.2.34.1INTEGERread-writeEnable/Disable accessing the device via Telnet. disable - no one will be allowed to access the device via Telnet. enable - all users are allowed Telnet Access. managersOnly - Only manager stations listed in the manager's list are allowed. enableSecure - same as 'enable' above + only Secure data will be accepted (SSH) managersOnlySecure - same as 'managersOnly' above + only Secure data will be accepted (SSH).
INT agnWebAccess1.3.6.1.4.1.164.6.2.34.2INTEGERread-writeEnable/Disable accessing the device via Web. disable - no one will be allowed to access the device via Web. enable - all users are allowed Web Access. managersOnly - Only manager stations listed in the manager's list are allowed. enableSecure - same as 'enable' above + only Secure data will be accepted (SSL) managersOnlySecure - same as 'managersOnly' above + only Secure data will be accepted (SSL).
INT agnRadiusAccess1.3.6.1.4.1.164.6.2.34.3INTEGERread-writeEnable/Disable authentication via RADIUS server.
INT agnSshAccess1.3.6.1.4.1.164.6.2.34.4INTEGERread-writeEnable/Disable accessing the device via SSH. disable - no one will be allowed to access the device via SSH. enable - all users are allowed SSH Access. managersOnly - Only manager stations listed in the manager's list are allowed.
systemInterface1.3.6.1.4.1.164.6.2.35
ifCreateTable1.3.6.1.4.1.164.6.2.35.1not-accessibleThe Interface Configuration Table. This table enables to create interfaces of Entities.
ifCreateEntry1.3.6.1.4.1.164.6.2.35.1.1not-accessibleAn entry in the Interface Configuration table.
SYS ifCreateEntityType1.3.6.1.4.1.164.6.2.35.1.1.1SysIfEntityTyperead-onlyThis object indicates the Type of the Entity that exists above the created interface. For a Logical Port, this value can be: other (1) when there is no fixed entity above it.
I32 ifCreateEntityIdx1.3.6.1.4.1.164.6.2.35.1.1.2Integer32read-onlyThis object indicates the Index of the Entity that exists above the created interface. For a Logical Port, this value can be: 9999 - N/A when there is no fixed entity above it.
I32 ifCreateNumber1.3.6.1.4.1.164.6.2.35.1.1.3Integer32read-onlyThis object indicates the number of the Interface that is created.
ROW ifCreateRowStatus1.3.6.1.4.1.164.6.2.35.1.1.4RowStatusread-createThis object enables the user to create/delete entries in this table.
IAN ifCreateType1.3.6.1.4.1.164.6.2.35.1.1.5IANAifTyperead-createThis object indicates the Type of the Interface that is created.
I32 ifCreateIndex1.3.6.1.4.1.164.6.2.35.1.1.6Integer32read-onlyThis object indicates the ifIndex of the created Interface. The ifIndex is assigned by the device.
I32 ifCreateConnectedTo1.3.6.1.4.1.164.6.2.35.1.1.7Integer32read-createThis object indicates the entity connected to the created Interface. The value of this object can be ifIndex of the connected entity or any other number that can identify it.
U32 ifCreateParams1.3.6.1.4.1.164.6.2.35.1.1.8Unsigned32read-createThis object represents one or more parameters of the created Interface. Each group of bits (one or more bits) represents a specific parameter and its possible values. This object's mapping and interpretation will be specified in each device's specification documents. The parameter should be used within the create PDU assuming atomic operation.
NUM ifCreateConnectionPointer1.3.6.1.4.1.164.6.2.35.1.1.9RowPointerread-createThis parameter represents the entity that is connected to this Interface. It can be used instead of ifCreateConnectedTo. It is an OBJECT IDENTIFIER. This parameter's SYNTAX allows the following possibilities: - can be simply used for entity that is not an interface - is not limited to include up to 32 bits The value of this parameter is a pointer to an existing row of a table, where the entity connected to this Interface is defined (i.e. the pointer uniquely identifies the connected entity). Examples: In case of an interface (from 2863.ifTable): points to 'ifEntry' of corresponding row = . In case of a VPI/VCI (from 2515.atmVclTable): points to 'atmVclEntry' of corresponding row = ..VPI.VCI In case no entity is connected, value = 0 .
interfacePerformance1.3.6.1.4.1.164.6.2.35.2
ifPerfTable1.3.6.1.4.1.164.6.2.35.2.1not-accessibleInterface Performance Table. The propose of this table is to support statistics counters having 64 bit by using 2 parameters with syntax= Integer32. This is because SNMPv1 does not support Counter64 properly. For SNMPv3, ifPerfHCCounter (Counter64) may be supported.
ifPerfEntry1.3.6.1.4.1.164.6.2.35.2.1.1not-accessibleAn entry in the Interface Performance Table.
I32 ifPerfCounterType1.3.6.1.4.1.164.6.2.35.2.1.1.1Integer32not-accessible2nd index of the ifPerfTable. This parameter represents the Counter Type. Each application can have a different association between this object's value and counter type - see relevant application spec. For VPLS-MTU application use the following values: 1= Rx Octets, 2= Tx Octets, 3= Rx Frames, 4= Tx Frames, 5=Rx Dropped Frames, 6= Tx Dropped Frames. Optionally, counter type description appears in agnListDecodingTable
U32 ifPerfLowCounterPart1.3.6.1.4.1.164.6.2.35.2.1.1.2Unsigned32read-onlyIn order to support Counters having 64 bit length, the performance counter is divided into two 32 bit parameters as follows: [ 64 bit parameter ] = [ High 32 bit parameter ][ Low 32 bit parameter ]. This parameter holds the Low 32 bits of the counter, while the following parameter holds the High 32 bits of the counter.
U32 ifPerfHighCounterPart1.3.6.1.4.1.164.6.2.35.2.1.1.3Unsigned32read-onlyThis parameter holds the High 32 bits of the counter (see description in the above parameter).
C64 ifPerfHCCounter1.3.6.1.4.1.164.6.2.35.2.1.1.4Counter64read-onlyThis High Capacity counter holds whole 64 bits of the counter indicated by ifPerfCounterType (concatenates both counter parts ifPerfHighCounterPart&ifPerfLowCounterPart) This object can be supported only by agents using SNMPv2 or SNMPv3.
systemOam1.3.6.1.4.1.164.6.2.36
systemOamTable1.3.6.1.4.1.164.6.2.36.1not-accessibleThe OAM Configuration Table.
systemOamEntry1.3.6.1.4.1.164.6.2.36.1.1not-accessibleAn entry in the OAM table.
I32 systemOamCnfgIdx1.3.6.1.4.1.164.6.2.36.1.1.1Integer32not-accessibleThis attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
I32 systemOamFrequency1.3.6.1.4.1.164.6.2.36.1.1.2Integer32read-writeTime in sec. between 2 OAM packets.
I32 systemOamTimeoutCycles1.3.6.1.4.1.164.6.2.36.1.1.3Integer32read-writeNo. of cycles the agent will send OAM packets without receiving a response from the remote device before declaring that the connection to the remote side is down - Time Out.
INT systemOamLinkCheck1.3.6.1.4.1.164.6.2.36.1.1.4INTEGERread-writeThis MIB object determines whether continuous connectivity Link checks will be performed by the device for uplinks. For Vmux-2100: enable (3) value can be set upon device installation. In this case, TDM Link Connectivity checks can be performed even before the user configures the Links of the device.If the value is enable (3) and there is no connection with the remote side, the Test LED will blink on the Main Board Module.
systemOamDescrTable1.3.6.1.4.1.164.6.2.36.2not-accessibleThe OAM Descriptors Configuration Table.
systemOamDescrEntry1.3.6.1.4.1.164.6.2.36.2.1not-accessibleAn entry in the OAM table.
I32 systemOamDescrIdx1.3.6.1.4.1.164.6.2.36.2.1.1Integer32not-accessibleThe OAM Descriptor Index.
ROW systemOamDescrRowStatus1.3.6.1.4.1.164.6.2.36.2.1.2RowStatusread-createEnables the user to create/delete entries in this table.
INT systemOamDescrMode1.3.6.1.4.1.164.6.2.36.2.1.3INTEGERread-createThe OAM Mode of the Descriptor.
INT systemOamDescrCCDirection1.3.6.1.4.1.164.6.2.36.2.1.4INTEGERread-createOAM Continuity Check function mode. both(2) - Agent sends OAM CC cells and checks received OAM CC cells. none(3) - Agent does not send and does not check received OAM CC cells. source(4)- Agent sends OAM CC cells. sink(5) - Agent checks received OAM CC cells.
INT systemOamDescrLoopbackOperation1.3.6.1.4.1.164.6.2.36.2.1.5INTEGERread-createThe OAM Loopback function mode. off(2) - Stop sending loopback OAM cells. on(3) - Start loopback OAM cells.
OCT systemOamDescrLoopbackDestAddr1.3.6.1.4.1.164.6.2.36.2.1.6OCTET STRINGread-createLoopback Destination Address.
G32 systemOamDescrXcCounter1.3.6.1.4.1.164.6.2.36.2.1.7Gauge32read-onlyThe number of connections that use this OAM Descriptor.
INT agnDeviceView1.3.6.1.4.1.164.6.2.37INTEGERread-onlyThis variable denotes the view of the device: Look: old look, new look or new look 2. Material: Plastic or Metal.
bitMappingTable1.3.6.1.4.1.164.6.2.38not-accessibleThis table maps bits of an octet string to an interface. For ACE-2002 this table is used to map bits of VLAN port lists to LAN VCC's. This table is the opposite view of the xcTable for xcBitMapping. It is used to ease the bit translation for the NMS.
bitMappingEntry1.3.6.1.4.1.164.6.2.38.1not-accessibleEach entry in the table describes a correlation of a bit location to an interface. For ACE-2002 - Upon creation of a new LAN VCC the agent will add an entry to this table that will define the bit location for that VCC.
I32 bitMappingLocation1.3.6.1.4.1.164.6.2.38.1.1Integer32not-accessibleThe bit location in an octet string.
I32 bitMappingIndex1.3.6.1.4.1.164.6.2.38.1.2Integer32read-onlyThe interface index or any other index that should be mapped.
OCT bitMappingView1.3.6.1.4.1.164.6.2.39OCTET STRINGread-onlyA view of the bitMappingTable in one object - each entry in the biMappingTable will have the corresponding Bit of this object (bitMappingLocation) = '1'. For ACE-2002 it is used to describe all the existing LAN VCC's So that the NMS can easily calculate which VCC's can be selected as members for a VLAN, instead of reading all the bitMapping Table.
hostTable1.3.6.1.4.1.164.6.2.40not-accessibleHost interface table.
hostEntry1.3.6.1.4.1.164.6.2.40.1not-accessibleAn entry in the Host Table. The hostParam1, hostParam2, and hostParam3 entries may have different use in different applications.
I32 hostIndex1.3.6.1.4.1.164.6.2.40.1.1Integer32not-accessibleThe Host Table Index. This index can have the same value as Host No.
IP hostIP1.3.6.1.4.1.164.6.2.40.1.2IpAddressread-createThe host interface IP address.
IP hostIPMask1.3.6.1.4.1.164.6.2.40.1.3IpAddressread-createThe host interface subnet mask.
IP hostDefaultNextHop1.3.6.1.4.1.164.6.2.40.1.4IpAddressread-createThe host interface Default Next Hop address.
I32 hostMode1.3.6.1.4.1.164.6.2.40.1.5Integer32read-createThis parameter represents the Host mode of operation. There can be different values for each application. For example: Not Applicable = 1.
I32 hostParam11.3.6.1.4.1.164.6.2.40.1.6Integer32read-createThis parameter represents the first Host parameter. There can be different values for each application. For example: Not Applicable = 1.
I32 hostParam21.3.6.1.4.1.164.6.2.40.1.7Integer32read-createThis parameter represents the 2nd Host parameter. There can be different values for each application.
I32 hostParam31.3.6.1.4.1.164.6.2.40.1.8Integer32read-createThis parameter represents the 3nd Host parameter. There can be different values for each application.
ROW hostRowStatus1.3.6.1.4.1.164.6.2.40.1.9RowStatusread-createCreation/Deletion of rows in the table.
INT hostVlanTagging1.3.6.1.4.1.164.6.2.40.1.10INTEGERread-createHost VLAN support (Tagging). untag - No support of VLAN Tagging. tag - 4 VLAN bytes will be added to the frame.
I32 hostVlanId1.3.6.1.4.1.164.6.2.40.1.11Integer32read-createHost VLAN ID.
I32 hostVlanPriority1.3.6.1.4.1.164.6.2.40.1.12Integer32read-createHost VLAN Frame priority.
invNameXCTable1.3.6.1.4.1.164.6.2.41not-accessibleInverse Name XC Table. This table can be used to ease the search for a connection first index by the connection name.
invNameXCEntry1.3.6.1.4.1.164.6.2.41.1not-accessibleAn entry in the table.
STR invNameXC1.3.6.1.4.1.164.6.2.41.1.1SnmpAdminStringnot-accessibleThe unique Connection name, associated to a Cross-Connection.
OID invNameXCType1.3.6.1.4.1.164.6.2.41.1.2OBJECT IDENTIFIERread-onlyThe OBJECT IDENTIFIER of the respective XC Table. Examples: XC Table invNameXCType --------------------------------------------------- atmVpCrossConnectTable 1.3.6.1.2.1.37.1.9 atmVcCrossConnectTable 1.3.6.1.2.1.37.1.11 atmfCESConfTable 1.3.6.1.4.1.353.5.2.2.1.1 .
I32 invNameXCIndex1.3.6.1.4.1.164.6.2.41.1.3Integer32read-onlyThe XC Table (invNameXCType) may include more than one index. This object represents the value of the first XC Index.
OCT agnDeviceCapabilities1.3.6.1.4.1.164.6.2.42OCTET STRINGread-onlyIndicates the optional capabilities that are implemented by this device and are manageable through this MIB. For each capability 1 BIT is allocated in each Octet starting from the LSB. If the value of the BIT = 1, the capability is Enabled. If the value of the BIT = 0, the capability is Disabled. For bit assignment, refer to device specification. Capabilities example: Router - BIT 0 (0000 0001 = 01 Hex = 1 Decimal). The 2nd octet (MSB) will represent the maximum number of intervals that the Agent can keep in its DB (same for all ports). For Vmux, this object describes agent's support of LBRAD coder feature: 1 octet ; bit 0 (LSB). '1' - LBRAD feature is supported '0' - LBRAD feature is not supported.
rowInfoTable1.3.6.1.4.1.164.6.2.43not-accessibleThis table holds information of other tables.
rowInfoEntry1.3.6.1.4.1.164.6.2.43.1not-accessibleAn entry in the table.
OID rowInfoTableId1.3.6.1.4.1.164.6.2.43.1.1OBJECT IDENTIFIERnot-accessibleThe OBJECT IDENTIFIER of the Table, which its information is held by this table (rowInfoTable). Examples: Table Name rowInfoTableId --------------------------------------------------- atmTrafficDescrParamTable 1.3.6.1.2.1.37.1.5 atmVpCrossConnectTable 1.3.6.1.2.1.37.1.9 atmVcCrossConnectTable 1.3.6.1.2.1.37.1.11 atmfCESConfTable 1.3.6.1.4.1.353.5.2.2.1.1 .
I32 rowInfoCounter1.3.6.1.4.1.164.6.2.43.1.2Integer32read-onlyThe Number of rows in the table, indicated by rowInfoTableId.
I32 rowInfoIndexNext1.3.6.1.4.1.164.6.2.43.1.3Integer32read-onlyThe First Free Index of the table, indicated by rowInfoTableId.
I32 rowInfoMaxNoOfRows1.3.6.1.4.1.164.6.2.43.1.4Integer32read-onlyThe maximum possible number of rows in the table, indicated by rowInfoTableId.
INT agnStoreCmd1.3.6.1.4.1.164.6.2.44INTEGERread-writeStore command. inFlash(3) = store the current Agent configuration in Flash memory. asDefConfigFile(4) = store the current Agent configuration as Default Configuration file (e.g. 'DefConfig.cfg'). Agent will perform the required command and change automatically the value of this object to off(2).
agnFunctionTable1.3.6.1.4.1.164.6.2.45not-accessibleThis table is used in order to activate/deactivate device functions. The index indicates the function. Each function can be Enabled or Disabled.
agnFunctionEntry1.3.6.1.4.1.164.6.2.45.1not-accessibleAn entry in the table.
INT agnFunction1.3.6.1.4.1.164.6.2.45.1.1INTEGERnot-accessibleThis MIB object indicates the function that will be enabled or disabled in the device. alarmForwarding= Fault Propagation (usually towards user port). For Vmux: routing (2) - enable/disable Router backup (3) - enable/disable Backup between E1/T1/Serial Link and ETH. uplinkLoopDetect (5) - enable/disable Loop Detection on the TDM Uplink. systemClock (6) - enable/disable the System Clock.
INT agnFunctionActivation1.3.6.1.4.1.164.6.2.45.1.2INTEGERread-writeThis MIB object indicates the activation of the current function.
I32 agnManagerConfigPorts1.3.6.1.4.1.164.6.2.46Integer32read-writeThis variable defines from which port/s this manager can manage the device. The value is a sum of 2**n, where n is a bit assigned to a certain port. For RIC-E1 and ETX 102 the value will be according to the ports combination: Network = bit 0 User= bit 1 For Example: All = 3.
INT agnEgressRateRange1.3.6.1.4.1.164.6.2.47INTEGERread-writeThis variable defines the valid ranges of egress rate. For example, for ETX 102: range 1 (2)= 128KBPS - 8MBPS, range 2 (3)= 256KBPS - 16MBPS, range 3 (4)= 512KBPS - 32MBPS, range 4 (5)= 1MBPS - 64MBPS, range 5 (6)= 1.5MBPS - 80MBPS.
I32 agnNoOfCurrentConns1.3.6.1.4.1.164.6.2.48Integer32read-onlyThis variable indicates the number of connections currently configured for the agent.
INT agnIngressRateRange1.3.6.1.4.1.164.6.2.49INTEGERread-writeThis variable defines the valid ranges of ingress rate. For example, for ETX 102: range 1 (2)= 128KBPS - 8MBPS, range 2 (3)= 256KBPS - 16MBPS, range 3 (4)= 512KBPS - 32MBPS, range 4 (5)= 1MBPS - 64MBPS, range 5 (6)= 1.5MBPS - 80MBPS.
alarmForwardingTable1.3.6.1.4.1.164.6.2.50not-accessibleThe Alarm Forwarding Mechanism will be operated for this table entries.
alarmForwardingEntry1.3.6.1.4.1.164.6.2.50.1not-accessibleEach entry in this table is a pair of ports that the Alarm Forwarding Mechanism is determined for.
I32 alarmForwardingFailPort1.3.6.1.4.1.164.6.2.50.1.1Integer32not-accessibleAn Index of the port on which a fail occurs.
I32 alarmForwardingToPort1.3.6.1.4.1.164.6.2.50.1.2Integer32not-accessibleAn Index of the port that will be affected upon the failure of the alarmForwardingFailPort.
ROW alarmForwardingRowStatus1.3.6.1.4.1.164.6.2.50.1.3RowStatusread-createCreation/ Deletion of rows in the table.
I32 alarmForwardingRecoveryTime1.3.6.1.4.1.164.6.2.50.1.4Integer32read-createThis parameter defines the maximum time (sec) the affected port will hold the down state.
I32 alarmForwardingGroupConditions1.3.6.1.4.1.164.6.2.50.1.5Integer32read-createThis parameter is applicable when there is a group of interfaces in which a fault may occur, and one interface to which alarm is propagated (forwarded). 0 = All - Forwarding will take place only when all interfaces of the same group are faulty. 1 = Single - Forwarding will take place when at least one (single) interface of the same group (any of them) is faulty. n - forwarding will take place only when n (n < all) interfaces of the same group fail.
BIT alarmForwardingCause1.3.6.1.4.1.164.6.2.50.1.6Bitsread-createBit map representing the cause upon which alarm forwarding will take place. bit 0 - LOSS (LINE DOWN) bit 1 - AIS bit 2 - RDI bit 3 - PROTOCOL DOWN.
INT alarmForwardingRecoveryMode1.3.6.1.4.1.164.6.2.50.1.7INTEGERread-createThis parameter determines the Recovery Mode. manual - The user should stop the alarm forwarding by using the alarmForwardingRecoveryCommand. automatic - Alarm forwarding will be automatically stopped upon alarmForwardingFailPort recovery.
INT alarmForwardingRecoveryCommand1.3.6.1.4.1.164.6.2.50.1.8INTEGERread-createThis parameter is a command. It is applicable when alarmForwardingRecoveryMode = manual. on - Will stop alarm forwarding. After setting to 'On', the agent will set this parameter back to 'Off'.
U32 alarmForwardingDelay1.3.6.1.4.1.164.6.2.50.1.9Unsigned32read-createThis parameter determines the period of time (in seconds) the alarm of the alarmForwardingFailPort should exist before starting alarm forwarding.
INT alarmForwardingDirection1.3.6.1.4.1.164.6.2.50.1.10INTEGERread-createThis parameter determines the Direction of the Alarm Forwarding. unidirectional - alarmForwardingFailPort affects the alarmForwardingToPort. bidirectional - alarmForwardingFailPort affects the alarmForwardingToPort AND vice-versa. For such cases, this value will be selected, instead of entering an additional unidirectional entry in the table, where the indexes are swapped.
BIT alarmForwardingAction1.3.6.1.4.1.164.6.2.50.1.11Bitsread-createBit map representing the action to be performed when alarm forwarding will take place. bit 0 - No Action. '1' value - device should NOT perform any action, though other bits indicate the action to be taken. '0' value - device should perform the action/s indicated by rest of the bits. In this case, one of the other bits should be '1'. bit 1 - Interface Deactivation (of the affected Port: alarmForwardingToPort) bit 2 - OAM Signaling. Affected Port (alarmForwardingToPort) will send special OAM Signaling to the Far-End unit about the Failure. This object will be used only for devices that support Deactivation per entry OR can support more than one action.
INT agnSwVersionSwapCmd1.3.6.1.4.1.164.6.2.51INTEGERread-writeSW switch command. mainAndBackup (3) = Swap between Main SW and the backup one. Agent will perform the required command and change automatically the value of this object to off(2).
agnClockSource1.3.6.1.4.1.164.6.2.52
agnClkSrcPortTable1.3.6.1.4.1.164.6.2.52.1not-accessiblePool of Ports for the Master/Fallback Clock Source and of Recovered IDs. For devices with more than one configuration: Set operation is valid only to the TmpCnfg entry.
agnClkSrcPortEntry1.3.6.1.4.1.164.6.2.52.1.1not-accessibleAn entry in the table.
I32 agnClkSrcPortCnfgIdx1.3.6.1.4.1.164.6.2.52.1.1.1Integer32not-accessibleThis object indicates the Idx of the Cnfg being accessed ; Idx of 255 relates to the TmpCnfg. For product supporting a single configuration, the value will be 1.
INT agnClkSrcPortSrcIdx1.3.6.1.4.1.164.6.2.52.1.1.2INTEGERnot-accessibleClock Source Index. master - refers to Master clock fallback - refers to Fallback clock recovered - refers to Recovered clock.
I32 agnClkSrcPortIdx1.3.6.1.4.1.164.6.2.52.1.1.3Integer32not-accessibleThis object indicates the running Idx of the port that is to be used as Clock Source, for each agnClkSrcPortSrcIdx instance. In case of Recovered Clock - it indicates the Clock ID.
I32 agnClkSrcPort1.3.6.1.4.1.164.6.2.52.1.1.4Integer32read-createThis object indicates the Port/Interface Index of the port that is to be used as Clock Source. In case of Recovered Clock - it indicates the PW number.
ROW agnClkSrcPortRowStatus1.3.6.1.4.1.164.6.2.52.1.1.5RowStatusread-createThis object enables Creation/ Deletion of rows in the table.
INT agnClkSrcPortAdminStatus1.3.6.1.4.1.164.6.2.52.1.1.6INTEGERread-createThis object indicates the Recovered Clock Administrative Status.
INT agnClkSrcPortType1.3.6.1.4.1.164.6.2.52.1.1.7INTEGERread-createThis object is relevant only in case of Recovery Clock. It indicates the Clock Type.
INT agnClkSrcPortQuality1.3.6.1.4.1.164.6.2.52.1.1.8INTEGERread-createThis object indicates the Clock Source Quality.
INT agnClkSrcPortNetType1.3.6.1.4.1.164.6.2.52.1.1.9INTEGERread-createThis object is relevant only in case of Recovery Clock. It indicates the Clock Network Type, i.e. the PSN network characteristics and behavior.
INT agnClkSrcPortState1.3.6.1.4.1.164.6.2.52.1.1.10INTEGERread-onlyThis object indicates the Clock State. freeRun(1) - Clock recovery is not locked to any clock. frequencyAcquisition(2) - Adaptive clock recovery is learning the frequency. rapidPhaseLock(3) - Clock recovery is in training process till it reaches fine phase lock. finePhaseLock(4) - Clock is locked and clock recovery is qualified and stable. holdover(5) - Clock recovery is in holdover mode. notApplicable(6) - Clock recovery is not applicable. .
agnCurrClkTable1.3.6.1.4.1.164.6.2.52.2not-accessibleCurrent Clock Source.
agnCurrClkEntry1.3.6.1.4.1.164.6.2.52.2.1not-accessibleAn entry in the table.
I32 agnCurrClkObjIdx1.3.6.1.4.1.164.6.2.52.2.1.1Integer32not-accessibleThis MIB object identifies the object for which the Clock Source is used (System, Other System, Card).
INT agnCurrClkMode1.3.6.1.4.1.164.6.2.52.2.1.2INTEGERread-onlyCurrent Clock Source Mode. master - refers Master clock fallback - refers Fallback clock internal - only when both Master and Fallback Sources failed
INT agnCurrClkSrc1.3.6.1.4.1.164.6.2.52.2.1.3INTEGERread-onlyThis object indicates the Current Clock Source.
I32 agnCurrClkPort1.3.6.1.4.1.164.6.2.52.2.1.4Integer32read-onlyThis object indicates the Port/Interface Index of the port that is Currently used as Clock Source.
INT agnCurrClkHoldover1.3.6.1.4.1.164.6.2.52.2.1.5INTEGERread-onlyCurrent Clock Holdover State. As a last resort, in the absence of higher quality timing: - a SONET/SDH object can enter 'holdover' state, until higher quality external timing becomes available again. In this state (value=yes) the SONET/SDH object uses its own timing circuits for clock of the SONET/SDH signal. - for other objects, the 'holdover'=yes state means that the object uses last available clock (stored by the object) for a pre-defined time, until another clock source is used.
INT agnCurrClkSsmBased1.3.6.1.4.1.164.6.2.52.2.1.6INTEGERread-onlyThis parameter indicates whether clock source is selected based on receive clock quality. Clock quality is indicated in S1 byte inside SONET/SDH overhead, (encoded as SSM - Synchronization Status Messaging).
INT agnCurrClkState1.3.6.1.4.1.164.6.2.52.2.1.7INTEGERread-onlyThis object indicates the Current Clock State. freeRun(1) - Current clock state machine is not locked and run from the internal oscillator. rapidPhaseLock(2) - Current clock state machine is locked. finePhaseLock(3) - Current clock state machine is in pre-locking. holdover(4) - Current clock state machine is in holdover mode (due to loss of event). .
INT agnCurrClkQualification1.3.6.1.4.1.164.6.2.52.2.1.8INTEGERread-onlyThis object indicates the Current Clock Qualification and defines whether the PLL can locked according to the stratum definitions.
agnClockMonitoring1.3.6.1.4.1.164.6.2.52.3
agnClkCurrentTable1.3.6.1.4.1.164.6.2.52.3.1not-accessibleThe Clock Current table.
agnClkCurrentEntry1.3.6.1.4.1.164.6.2.52.3.1.1not-accessibleAn entry in the Clock Current table.
U32 agnClkCurrentIndex1.3.6.1.4.1.164.6.2.52.3.1.1.1Unsigned32not-accessibleAn Index that is uniquely represents the Clock.
G32 agnClkCurrentRxPackets1.3.6.1.4.1.164.6.2.52.3.1.1.2Gauge32read-onlyThe counter associated with the number of Received Packets, encountered by a Bridge Port in the current 15 minute interval.
G32 agnClkCurrentLostPackets1.3.6.1.4.1.164.6.2.52.3.1.1.3Gauge32read-onlyThe counter associated with the number of Lost Packets, encountered by a Bridge Port in the current 15 minute interval.
G32 agnClkCurrentOutOfOrderPackets1.3.6.1.4.1.164.6.2.52.3.1.1.4Gauge32read-onlyThe counter associated with the number of times Out-of-Order Packets encountered by a Bridge Port in the current 15 minute interval.
G32 agnClkCurrentBufferUnderflow1.3.6.1.4.1.164.6.2.52.3.1.1.5Gauge32read-onlyThe counter associated with the number of times Underflow event encountered by a Bridge Port in the current 15 minute interval.
agnClkIntervalTable1.3.6.1.4.1.164.6.2.52.3.2not-accessibleThe Clock Interval table.
agnClkIntervalEntry1.3.6.1.4.1.164.6.2.52.3.2.1not-accessibleAn entry in the Clock Interval table.
U32 agnClkIntervalIndex1.3.6.1.4.1.164.6.2.52.3.2.1.1Unsigned32not-accessibleAn Index that is uniquely represents the Clock.
U32 agnClkIntervalNumber1.3.6.1.4.1.164.6.2.52.3.2.1.2Unsigned32not-accessibleA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist).
G32 agnClkIntervalRxPackets1.3.6.1.4.1.164.6.2.52.3.2.1.3Gauge32read-onlyThe counter associated with the number of Received Packets, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
G32 agnClkIntervalLostPackets1.3.6.1.4.1.164.6.2.52.3.2.1.4Gauge32read-onlyThe counter associated with the number of Lost Packets, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
G32 agnClkIntervalOutOfOrderPackets1.3.6.1.4.1.164.6.2.52.3.2.1.5Gauge32read-onlyThe counter associated with the number of times Out-of-Order Packets are detected, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
G32 agnClkIntervalBufferUnderflow1.3.6.1.4.1.164.6.2.52.3.2.1.6Gauge32read-onlyThe counter associated with the number of times Underflow event is detected, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
I32 agnMaxNoOfConns1.3.6.1.4.1.164.6.2.53Integer32read-onlyThis variable indicates the maximum number of connections that can be configured for the agent.
lag1.3.6.1.4.1.164.6.2.54
lagTable1.3.6.1.4.1.164.6.2.54.1not-accessibleA table defining Link Aggregation Groups port association, and other parameters.
lagEntry1.3.6.1.4.1.164.6.2.54.1.1not-accessibleAn entry in the LAG table.
U32 lagCnfgIdx1.3.6.1.4.1.164.6.2.54.1.1.1Unsigned32not-accessibleThis object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
U32 lagIdx1.3.6.1.4.1.164.6.2.54.1.1.2Unsigned32not-accessibleThis object indicates LAG unique index.
POR lagPortMembers1.3.6.1.4.1.164.6.2.54.1.1.3PortListread-createThe set of ports which are permanently assigned to the Link Aggregation Group. The default value of this object is a string of zeros.
INT lagDistributionMethod1.3.6.1.4.1.164.6.2.54.1.1.4INTEGERread-createThis object defines the criteria for the 802.3ad (LAG) to split the traffic between ports
INT lagRecoveryMode1.3.6.1.4.1.164.6.2.54.1.1.5INTEGERread-createThis object defines whether traffic will be returned to a port after its recovery. This object is applicable only when lagDistributionMethod= oneToOne (3).
U32 lagWaitToRestore1.3.6.1.4.1.164.6.2.54.1.1.6Unsigned32read-createThis object defines traffic recovery time (in seconds) to the port after its recovery. This object is applicable only when lagRecoveryMode= revertive (3).
ROW lagRowStatus1.3.6.1.4.1.164.6.2.54.1.1.7RowStatusread-createThis object enables user to create/delete entries of this table. Note: When using LAG standard package, this table is static, hence, only the values active(1), notInService(2) are used.
U32 lagShutDownDurationUponFlip1.3.6.1.4.1.164.6.2.54.1.1.8Unsigned32read-createThis object defines the duration (in seconds) the active port transmission is shut down after LAG Flip occurs. The transmission is shut down and then opened again (after the duration defined by this object), in order to cause the other side to flip to the new active port. 0=no shut-down. This object is applicable only when lagDistributionMethod=oneToOne(3) and mainly when each of the Links of our device is connected to a different device.
INT lagRdnMethod1.3.6.1.4.1.164.6.2.54.1.1.9INTEGERread-createThis object defines the redundancy method.
INT lagLacpEnable1.3.6.1.4.1.164.6.2.54.1.1.10INTEGERread-createEnabling/Disabling the LACP for a LAG. The LACP will be enabled for all ports belonging to this LAG.
lagStatTable1.3.6.1.4.1.164.6.2.54.2not-accessibleA table defining Link Aggregation Groups Redundancy. This table is applicable only when lagDistributionMethod = oneToOne.
lagStatEntry1.3.6.1.4.1.164.6.2.54.2.1not-accessibleAn entry in the LAG Status table.
U32 lagStatForcePort1.3.6.1.4.1.164.6.2.54.2.1.1Unsigned32read-writeThis object enables user to enforce the active port. 0 = No Enforcement; Otherwise the ifIndex of the port.
U32 lagStatActivePort1.3.6.1.4.1.164.6.2.54.2.1.2Unsigned32read-onlyThis object indicates the current active port. It is applicable only when lagDistributionMethod = oneToOne. The value is the ifIndex of the port. 0 = none of the ports is active.
gfp1.3.6.1.4.1.164.6.2.55
gfpCnfgTable1.3.6.1.4.1.164.6.2.55.1not-accessibleConfiguration table for GFP (General Framing Protocol).
gfpCnfgEntry1.3.6.1.4.1.164.6.2.55.1.1not-accessibleAn entry in the GFP configuration table.
U32 gfpCnfgIdx1.3.6.1.4.1.164.6.2.55.1.1.1Unsigned32not-accessibleIndex to GFP configuration table.
INT gfpPayloadFcs1.3.6.1.4.1.164.6.2.55.1.1.2INTEGERread-writeThis object defines whether protocol header will include FCS.
INT gfpRxTxScramble1.3.6.1.4.1.164.6.2.55.1.1.3INTEGERread-writeThis object defines whether transmission will be scrambled.
INT gfpVcatHeader1.3.6.1.4.1.164.6.2.55.1.1.4INTEGERread-writeVCAT header is LCAS CONTROL packet as described in the G-7043. one control packet is transmitted in a period of 16 Multi frame
agnGroupTable1.3.6.1.4.1.164.6.2.56not-accessibleA table that enables associating components to Group/s (or removing components of a group). The Group Idx can then be used in other tables (e.g alarmForwardingTable).
agnGroupEntry1.3.6.1.4.1.164.6.2.56.1not-accessibleAn entry in the agnGroupTable.
U32 agnGroupCnfgIdx1.3.6.1.4.1.164.6.2.56.1.1Unsigned32not-accessibleThis object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
U32 agnGroupIdx1.3.6.1.4.1.164.6.2.56.1.2Unsigned32not-accessibleThis object indicates a unique Group Index.
U32 agnGroupComponentIdx1.3.6.1.4.1.164.6.2.56.1.3Unsigned32not-accessibleThis object indicates a unique Component Index that belongs to the Group defined by agnGroupIdx.
ROW agnGroupRowStatus1.3.6.1.4.1.164.6.2.56.1.4RowStatusread-createThis object enables user to create/delete entries of this table. destroy - If a Group is used in another table, Agent may not allow destroying the entry/ies that belong to this Group Index.
I32 agnStatNoOfUploadedIntervals1.3.6.1.4.1.164.6.2.57Integer32read-onlyThis parameter indicates the Number of Intervals that were successfully collected and uploaded in the last statistics collection session.
agnSyslog1.3.6.1.4.1.164.6.2.58
U32 agnSyslogDeviceUdpPort1.3.6.1.4.1.164.6.2.58.1Unsigned32read-writeThe UDP Port of the device, from which Syslog messages are sent. Default=514.
INT agnSyslogFacility1.3.6.1.4.1.164.6.2.58.2INTEGERread-writeA user defined SW module, task or function, from which Syslog messages are sent to the remote Server.
INT agnSyslogSeverityLevel1.3.6.1.4.1.164.6.2.58.3INTEGERread-writeDevice will send events equal or exceeding this severity level (configured by user).
INT agnNetworkInterfaceType1.3.6.1.4.1.164.6.2.59INTEGERread-writeThis MIB object indicates the network interface type to be used by the device. It is used for devices that use only one network port type.
U32 agnTrapDelay1.3.6.1.4.1.164.6.2.60Unsigned32read-writeThis variable enables the user to set a delay (in seconds) before a trap is sent. This delay will be used only for traps that need to be sent during device initialization. It is needed because the device connected to our device starts transmitting traps later. The delay starts from the end of the Boot process. The device will keep the init traps in the correct order, and cancel those which clear former ones in the list. After this init delay, traps will be sent without a delay.
agnStringToIndexTable1.3.6.1.4.1.164.6.2.62not-accessibleThis table holds the conversions of tables from unique String to numeric index.
agnStringToIndexEntry1.3.6.1.4.1.164.6.2.62.1not-accessibleAn entry in the table.
OID agnStringToIndexTableId1.3.6.1.4.1.164.6.2.62.1.1OBJECT IDENTIFIERnot-accessibleThe OBJECT IDENTIFIER of the Table, having as index numeric values. In this table, the value of agnStringToIndexUserName is an attribute.
STR agnStringToIndexUserName1.3.6.1.4.1.164.6.2.62.1.2SnmpAdminStringnot-accessibleThis object indicates a unique name used by agnStringToIndexTableId, although it is not it's index.
U32 agnStringToIndexTableIndex1.3.6.1.4.1.164.6.2.62.1.3Unsigned32read-onlyThe numeric Index of agnStringToIndexTableId.
agnRowPointerTable1.3.6.1.4.1.164.6.2.63not-accessibleThis table holds information about a specific entry in a table. For example, number of usages of this row.
agnRowPointerEntry1.3.6.1.4.1.164.6.2.63.1not-accessibleAn entry in the table.
OID agnRowPointerIndex1.3.6.1.4.1.164.6.2.63.1.1OBJECT IDENTIFIERnot-accessibleThe OBJECT IDENTIFIER of an entry in a table.
U32 agnRowPointerNoOfUsages1.3.6.1.4.1.164.6.2.63.1.2Unsigned32read-onlyThe number of usages of specific entry in a table, which is pointed by agnRowPointerIndex.Usually, when the value of this counter is greater than 0,the entry cannot be removed.
services1.3.6.1.4.1.164.6.3
wfq1.3.6.1.4.1.164.6.3.1
wfqTable1.3.6.1.4.1.164.6.3.1.1not-accessibleThis table allows user to define several WFQ tables per output port. WFQ supports flows with different bandwidth requirements by giving each queue a weight that assigns it a different percentage of output port bandwidth. When Weighted Fair Queuing is used, it is possible to precisely attribute bandwidth partitioning among the queues. When there is congestion, each class (queue) is not allowed to use more bandwidth than the amount allocated to it.
wfqEntry1.3.6.1.4.1.164.6.3.1.1.1not-accessibleAn entry in the Weighted Fair Queueing table.
I32 wfqCnfgIdx1.3.6.1.4.1.164.6.3.1.1.1.1Integer32not-accessibleThis object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1.
I32 wfqPrtIdx1.3.6.1.4.1.164.6.3.1.1.1.2Integer32not-accessibleThis object indicates a unique port or interface number, for which Weighted Fair Queueing table is applicable . For numbering, see product's spec. For some products, the numbering can equal ifIndex. Value of 255 (not applicable) refer to system level queue
I32 wfqTblIdx1.3.6.1.4.1.164.6.3.1.1.1.3Integer32not-accessibleThis object indicates which Weighted Fair Queueing (WFQ) Table is being used. There can be several tables. For FCD-155 User will select which one will be used for a virtual concatenation group.Valid values are 1,2
I32 wfqQueueIdx1.3.6.1.4.1.164.6.3.1.1.1.4Integer32not-accessibleThis object indicates a queue index. For FCD-155, valid queues are 1..3. The 4th queue is not in MIB. Its weight will be RO, Calculated according to the sum of the 3 first queues.
ROW wfqRowStatus1.3.6.1.4.1.164.6.3.1.1.1.5RowStatusread-createThis object enables Creation/Deletion of rows in the WFQ table. For FCD-155, rows are not created nor destroyed by user.
I32 wfqWeightValue1.3.6.1.4.1.164.6.3.1.1.1.6Integer32read-createThis object indicates a relative weight value. User should make sure that the sum of values for all queues will not exceed 100% (sum should be BELOW 100% in order to leave some BW percentage for last queue) Note that when this attribute is being used, the wfqMinRateAbsolute attribute is NA.
INT wfqSchedulingMode1.3.6.1.4.1.164.6.3.1.1.1.7INTEGERread-createThis object controls which scheduling mode is used: Weighted Fair Queuing (WFQ) scheme or priority Queue (Strict Priority).
U32 wfqMinRateAbsolute1.3.6.1.4.1.164.6.3.1.1.1.8Unsigned32read-createThe minimum absolute rate, in kbps, that should be allocated to this queue. If the value is zero, then there is effectively no minimum rate guarantee. If the value is non-zero, then the servicing of this queue in at least this rate is assured. Note that when this attribute is being used, the wfqWeightValue attribute is NA.
U32 wfqMaxPacketSize1.3.6.1.4.1.164.6.3.1.1.1.9Unsigned32read-createThe size of the largest packet which can be received on this queue, specified in octets. Packets larger than this size will be discarded.
dscpMapping1.3.6.1.4.1.164.6.3.2
dscpMappingTable1.3.6.1.4.1.164.6.3.2.1not-accessibleMapping of DSCP value to a regenerated priority level.
dscpMappingEntry1.3.6.1.4.1.164.6.3.2.1.1not-accessibleAn entry in dscpMappingTable.
I32 dscpMappingCnfgIdx1.3.6.1.4.1.164.6.3.2.1.1.1Integer32not-accessibleThis object indicates the Idx of the Agent Cnfg the following objects refer to. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1. This object can be used to carry additional indexing (e.g port index) when needed.
DSC dscpMappingDscpIdx1.3.6.1.4.1.164.6.3.2.1.1.2Dscpnot-accessibleDSCP value of the incoming IP packet
I32 dscpMappingRegenPriority1.3.6.1.4.1.164.6.3.2.1.1.3Integer32read-writeThe Regenerated Priority level the incoming DSCP value is mapped to. For FCD-155, valid values are 0,1,2,3
ifTeQos1.3.6.1.4.1.164.6.3.3
ifTeQosTable1.3.6.1.4.1.164.6.3.3.1not-accessibleThe TE QOS Interface Table.
ifTeQosEntry1.3.6.1.4.1.164.6.3.3.1.1not-accessibleAn entry in the TE QOS Interface table.
I32 ifTeQosIdx11.3.6.1.4.1.164.6.3.3.1.1.1Integer32not-accessibleThis object indicates the 1st Index of the table.
I32 ifTeQosIdx21.3.6.1.4.1.164.6.3.3.1.1.2Integer32not-accessibleThis object indicates the 2nd Index of the table.
I32 ifTeQosIdx31.3.6.1.4.1.164.6.3.3.1.1.3Integer32not-accessibleThis object indicates the 3rd Index of the table.
OCT ifTeQosParam1.3.6.1.4.1.164.6.3.3.1.1.4OCTET STRINGread-writeThis object is used for QOS attributes of the entry's entities.
OCT ifTeQosParam21.3.6.1.4.1.164.6.3.3.1.1.5OCTET STRINGread-writeThis object is used for 2nd group QOS attributes of the entry's entities.
INT ifTeQosStatus1.3.6.1.4.1.164.6.3.3.1.1.6INTEGERread-writeThis object is used to create, activate and destroy entries of this table.
portQos1.3.6.1.4.1.164.6.3.4
prtPriorityTable1.3.6.1.4.1.164.6.3.4.1not-accessibleA table - Parameters per port per Priority .
prtPriorityEntry1.3.6.1.4.1.164.6.3.4.1.1not-accessibleAn entry in table.
I32 prtPriorityIdx11.3.6.1.4.1.164.6.3.4.1.1.1Integer32not-accessibleThis attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg. or any other Index.
I32 prtPriorityPrtIdx1.3.6.1.4.1.164.6.3.4.1.1.2Integer32not-accessibleThis object indicates a unique Port Index. Refer to device specification for port Index.
I32 prtPriorityIdx1.3.6.1.4.1.164.6.3.4.1.1.3Integer32not-accessibleThis object indicates the Traffic Priority Index.
I32 prtPriorityIngressRateLimit1.3.6.1.4.1.164.6.3.4.1.1.4Integer32read-writeThe maximum rate permitted at Ingress of this port with this Traffic Priority, in Kbps.
prtQosTable1.3.6.1.4.1.164.6.3.4.2not-accessiblePort QoS (Quality of Service) table.
prtQosEntry1.3.6.1.4.1.164.6.3.4.2.1not-accessibleAn entry in table.
U32 prtQosIdx1.3.6.1.4.1.164.6.3.4.2.1.1Unsigned32not-accessibleThe first index of the table. This attribute might indicate the Idx of the Cnfg (1..255) being accessed ; Idx of 255 relates to the TmpCnfg or any other Index.
U32 prtQosPrtIdx1.3.6.1.4.1.164.6.3.4.2.1.2Unsigned32not-accessibleThis object indicates a unique Port Index. Refer to device specification for port Index.
INT prtQosDirection1.3.6.1.4.1.164.6.3.4.2.1.3INTEGERnot-accessibleThis object indicates the port's QoS Direction.
INT prtQosRateLimitPacketType1.3.6.1.4.1.164.6.3.4.2.1.4INTEGERread-writeThis object indicates the Type of Packets on which Rate Limitation is applied.
U32 prtQosRateLimitCIR1.3.6.1.4.1.164.6.3.4.2.1.5Unsigned32read-writeThis object indicates the port's CIR (Committed Information Rate) in Kbps. Value=0 represents best effort.
U32 prtQosRateLimitCBS1.3.6.1.4.1.164.6.3.4.2.1.6Unsigned32read-writeThis object indicates the port's CBS (Committed Burst Size) in KB. Value=0 represents best effort.
U32 prtQosRateLimitEIR1.3.6.1.4.1.164.6.3.4.2.1.7Unsigned32read-writeThis object indicates the port's EIR (Excess Information Rate) in Kbps.
U32 prtQosRateLimitEBS1.3.6.1.4.1.164.6.3.4.2.1.8Unsigned32read-writeThis object indicates the port's EBS (Excess Burst Size) in KB.
prtTrafficClass1.3.6.1.4.1.164.6.3.5
portTrafficClassTable1.3.6.1.4.1.164.6.3.5.1not-accessibleMapping of port to Traffic Class level.
portTrafficClassEntry1.3.6.1.4.1.164.6.3.5.1.1not-accessibleAn entry in portTrafficClassTable.
I32 portTrafficClassIdx11.3.6.1.4.1.164.6.3.5.1.1.1Integer32not-accessibleThis attribute indicates the 1st index of the table. This may be the Idx of the Cnfg(1..255) being accessed; Idx of 255 relates to the TmpCnfg, or any other Index.
I32 portTrafficClassPortIdx1.3.6.1.4.1.164.6.3.5.1.1.2Integer32not-accessibleThis object indicates a unique Port Index. Refer to device specification for port Index.
I32 portTrafficClass1.3.6.1.4.1.164.6.3.5.1.1.3Integer32read-writeThis object indicates the Traffic Class level of this port.
serviceTable1.3.6.1.4.1.164.6.3.6not-accessibleTable of services.
serviceEntry1.3.6.1.4.1.164.6.3.6.1not-accessibleAn entry in the Service Table.
U32 flowIndex1.3.6.1.4.1.164.6.3.6.1.1Unsigned32not-accessibleDefines the Flow ID the service is associated to.
U32 serviceIndex1.3.6.1.4.1.164.6.3.6.1.2Unsigned32not-accessibleDefines the Service ID - according to the CoS.
ROW serviceRowStatus1.3.6.1.4.1.164.6.3.6.1.3RowStatusread-createThis attribute is used to create a new row or to delete an existing row in the table.
STR serviceName1.3.6.1.4.1.164.6.3.6.1.4SnmpAdminStringread-createThis attribute defines the service name.
U32 serviceBwProfileId1.3.6.1.4.1.164.6.3.6.1.5Unsigned32read-createThis variable holds the index of the Ingress BW profile assigned to that service.
evcCosTable1.3.6.1.4.1.164.6.3.7not-accessibleThis table defines mapping of Ethernet Virtual Connection (EVC) ID to Class of Service (CoS) ID
evcCosEntry1.3.6.1.4.1.164.6.3.7.1not-accessibleAn entry in table.
U32 evcCosCnfgIdx1.3.6.1.4.1.164.6.3.7.1.1Unsigned32not-accessibleThis attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
U32 evcCosEvcIdx1.3.6.1.4.1.164.6.3.7.1.2Unsigned32not-accessibleThis attribute indicates EVC Id.
ROW evcCosRowStatus1.3.6.1.4.1.164.6.3.7.1.3RowStatusread-createThis attribute allows to create/delete a row in this table.
STR evcCosEvcName1.3.6.1.4.1.164.6.3.7.1.5SnmpAdminStringread-createA string that identifies the EVC. It should be unique in the Maintenance Domain (i.e., in the managed network) Used as MEG ID field in OAM messages.
U32 evcCosSpVlanId1.3.6.1.4.1.164.6.3.7.1.6Unsigned32read-createThis object indicates the SP (Service Provider) VLAN used when sending an OAM message for the specified EVC.
serviceStatTable1.3.6.1.4.1.164.6.3.8not-accessibleService statistics table.
serviceStatEntry1.3.6.1.4.1.164.6.3.8.1not-accessibleAn entry in the Service Statistics Table.
INT serviceStatDirection1.3.6.1.4.1.164.6.3.8.1.1INTEGERnot-accessibleThe direction in wich the measurement is taken.
G32 srvForwardGreenPackets1.3.6.1.4.1.164.6.3.8.1.2Gauge32read-onlyThis attribute displays the counted number of forwarded packets that where marked Green.
G32 srvForwardGreenPacktesOverflow1.3.6.1.4.1.164.6.3.8.1.3Gauge32read-onlyThis attribute displays the number of times that the forwardGreenPackets counter has overflowed.
G32 srvForwardYellowPackets1.3.6.1.4.1.164.6.3.8.1.4Gauge32read-onlyThis attribute displays the counted number of forwarded packets that where marked Yellow.
G32 srvForwardYellowPacketsOverflow1.3.6.1.4.1.164.6.3.8.1.5Gauge32read-onlyThis attribute displays the number of times that the forwardYellowPackets counter has overflowed.
G32 srvDiscardGreenPacket1.3.6.1.4.1.164.6.3.8.1.6Gauge32read-onlyThis attribute displays the counted number of discarded packets that where marked Green.
G32 srvDiscardGreenPacketOverflow1.3.6.1.4.1.164.6.3.8.1.7Gauge32read-onlyThis attribute displays the number of times that the discardGreenPacket counter has overflowed.
G32 srvDiscardYellowRedPackets1.3.6.1.4.1.164.6.3.8.1.8Gauge32read-onlyThis attribute displays the counted number of discarded packets that where marked Yellow or Red.
G32 srvDiscardYellowRedPacketsOverflow1.3.6.1.4.1.164.6.3.8.1.9Gauge32read-onlyThis attribute displays the number of times that the discardYellowRedPackets counter has overflowed.
G32 srvForwardGreenBytes1.3.6.1.4.1.164.6.3.8.1.10Gauge32read-onlyThis attribute displays the counted number of forwarded bytes that where marked Green.
G32 srvForwardGreenBytesOverflow1.3.6.1.4.1.164.6.3.8.1.11Gauge32read-onlyThis attribute displays the number of times that the forwardGreenBytes counter has overflowed.
G32 srvForwardYellowBytes1.3.6.1.4.1.164.6.3.8.1.12Gauge32read-onlyThis attribute displays the counted number of forwarded bytes that where marked Yellow.
G32 srvForwardYellowBytesOverflow1.3.6.1.4.1.164.6.3.8.1.13Gauge32read-onlyThis attribute displays the number of times that the forwardYellowBytes counter has overflowed.
G32 srvDiscardGreenBytes1.3.6.1.4.1.164.6.3.8.1.14Gauge32read-onlyThis attribute displays the counted number of discarded bytes that where marked Green.
G32 srvDiscardGreenBytesOverflow1.3.6.1.4.1.164.6.3.8.1.15Gauge32read-onlyThis attribute displays the number of times that the discardGreenBytes counter has overflowed.
G32 srvDiscardYellowRedBytes1.3.6.1.4.1.164.6.3.8.1.16Gauge32read-onlyThis attribute displays the counted number of discarded bytes that where marked Yellow or Red.
G32 srvDiscardYellowRedBytesOverflow1.3.6.1.4.1.164.6.3.8.1.17Gauge32read-onlyThis attribute displays the number of times that the discardYellowRedBytes counter has overflowed.
INT srvResetStatsCmd1.3.6.1.4.1.164.6.3.8.1.18INTEGERread-createReset statistic counters of the service.
G32 srvDiscardYellowPackets1.3.6.1.4.1.164.6.3.8.1.19Gauge32read-onlyThis attribute displays the counted number of discarded packets that where marked Yellow.
G32 srvDiscardYellowPacketsOverflow1.3.6.1.4.1.164.6.3.8.1.20Gauge32read-onlyThis attribute displays the number of times that the discardYellowPackets counter has overflowed.
G32 srvDiscardYellowBytes1.3.6.1.4.1.164.6.3.8.1.21Gauge32read-onlyThis attribute displays the counted number of discarded bytes that where marked Yellow.
G32 srvDiscardYellowBytesOverflow1.3.6.1.4.1.164.6.3.8.1.22Gauge32read-onlyThis attribute displays the number of times that the discardYellowBytes counter has overflowed.
G32 srvDiscardRedPackets1.3.6.1.4.1.164.6.3.8.1.23Gauge32read-onlyThis attribute displays the counted number of discarded packets that where marked Red.
G32 srvDiscardRedPacketsOverflow1.3.6.1.4.1.164.6.3.8.1.24Gauge32read-onlyThis attribute displays the number of times that the discardRedPackets counter has overflowed.
G32 srvDiscardRedBytes1.3.6.1.4.1.164.6.3.8.1.25Gauge32read-onlyThis attribute displays the counted number of discarded bytes that where marked Red.
G32 srvDiscardRedBytesOverflow1.3.6.1.4.1.164.6.3.8.1.26Gauge32read-onlyThis attribute displays the number of times that the discardRedBytes counter has overflowed.
mappingProfileObjects1.3.6.1.4.1.164.6.3.9
flowMappingProfileTable1.3.6.1.4.1.164.6.3.9.1not-accessibleThis table holds flow mapping profiles.
flowMappingProfileEntry1.3.6.1.4.1.164.6.3.9.1.1not-accessibleEach entry in this table describes one Flow mapping profile with one of its Flow Mapping supported, according to the Priority order. The information includes a reference to a Flow Mapping index.
U32 flowMappingProfileIndex1.3.6.1.4.1.164.6.3.9.1.1.1Unsigned32not-accessibleA running index for the Flow Mapping Profile table.
INT flowMappingProfilePriority1.3.6.1.4.1.164.6.3.9.1.1.2INTEGERnot-accessibleThe priority of the Mapping selected by flowMappingProfileMapIndex within the Flow Mapping Profile.
ROW flowMappingProfileRowStatus1.3.6.1.4.1.164.6.3.9.1.1.3RowStatusread-createThis attribute is used to create a new row or to delete an existing row in the table.
U32 flowMappingProfileNumOfMaps1.3.6.1.4.1.164.6.3.9.1.1.4Unsigned32read-createThis attribute determines the number of the mappings associated to the Flow Mapping Profile.
U32 flowMappingProfileMapIndex1.3.6.1.4.1.164.6.3.9.1.1.5Unsigned32read-createThis attribute holds a reference to the mapping index. It specifies the mapping selected for the Mapping Profile for the selected Priority. When flowMappingProfileNumOfMaps=0, this attribute is not relevant.
STR flowMappingProfileName1.3.6.1.4.1.164.6.3.9.1.1.6SnmpAdminStringread-createThis attribute defines the name assigned to flowMappingIndex profile.
qosFlowMappingTable1.3.6.1.4.1.164.6.3.9.2not-accessibleA table of Flow Mapping.
qosFlowMappingEntry1.3.6.1.4.1.164.6.3.9.2.1not-accessibleEach entry in this table describes one Flow Mapping. The information includes combination (AND function) of all the classifications, as defined in the qosFlowMappingCriteria field. Classifiers are: TOS, DSCP, VLAN ID, MAC and IP source and destination addresses, IP protocol, IP Precedence, TCP and UDP source and destination ports.
U32 qosFlowMappingIdx11.3.6.1.4.1.164.6.3.9.2.1.1Unsigned32not-accessible- In case the table is accessed via flowMappingProfileTable this is a running index for the QoS Flow Mapping table. - In case the table is not accessed via flowMappingProfileTable, this will be the ifIndex of the XNI (bridge port) to which the QoS mapping applies.
U32 qosFlowMappingIdx21.3.6.1.4.1.164.6.3.9.2.1.2Unsigned32not-accessibleAn index for the QoS Flow Mapping table. - In case the table is accessed via flowMappingProfileTable the index will be fixed = 1. - In case the table is not accessed via flowMappingProfileTable, this will be the index of the Flow (EVC) to which the QoS mapping applies.
U32 qosFlowMappingIdx31.3.6.1.4.1.164.6.3.9.2.1.3Unsigned32not-accessibleAn index for the QoS Flow Mapping table. - In case the table is accessed via flowMappingProfileTable the index will be fixed = 1. - In case the table is not accessed via flowMappingProfileTable, this will be the Priority to which the QoS mapping applies.
ROW qosFlowMappingRowStatus1.3.6.1.4.1.164.6.3.9.2.1.4RowStatusread-createThis attribute is used to create a new row or to delete an existing row in the table.
BIT qosFlowMappingCriteria1.3.6.1.4.1.164.6.3.9.2.1.5Bitsread-createThis attribute determines upon which criterion the flow will be mapped.
U32 qosFlowMappingIeee802dot1p1.3.6.1.4.1.164.6.3.9.2.1.6Unsigned32read-createThis attribute determines which TOS values are applicable for that flow. Each bit (0..7) represents a different 802.1 P-bit value. Setting '1' to the bit means that the corresponding 802.1 P-bit value is applicable. It is relevant only in case the ieee802dot1p bit(0) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingTos1.3.6.1.4.1.164.6.3.9.2.1.7Unsigned32read-createThis attribute determines which TOS values are applicable for that flow. Each bit (0..7) represents a different TOS value. Setting '1' to the bit means that the corresponding TOS value is applicable. It is relevant only in case the tos bit (1) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingFromDscp1.3.6.1.4.1.164.6.3.9.2.1.8Unsigned32read-createThis attribute determines the first DSCP value to compare with in a range. It is relevant only in case the dscp bit (2) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingToDscp1.3.6.1.4.1.164.6.3.9.2.1.9Unsigned32read-createThis attribute determines the first DSCP value to compare with in a range. It is relevant only in case the dscp bit (2) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingFromVlanId1.3.6.1.4.1.164.6.3.9.2.1.10Unsigned32read-createThis attribute determines the first VLAN ID value to compare with in a range. It is relevant only in case the vlanId bit (3) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingToVlanId1.3.6.1.4.1.164.6.3.9.2.1.11Unsigned32read-createThis attribute determines the last VLAN ID value to compare with in a range. It is relevant only in case the vlanId bit (3) in qosFlowMappingCriteria equals 1.
MAC qosFlowMappingFromSrcMacAddr1.3.6.1.4.1.164.6.3.9.2.1.12MacAddressread-createThis attribute determines the first source MAC address to compare with in a range. It is relevant only in case the macSrcAddr bit (4) in qosFlowMappingCriteria equals 1.
MAC qosFlowMappingToSrcMacAddr1.3.6.1.4.1.164.6.3.9.2.1.13MacAddressread-createThis attribute determines the last source MAC address to compare with in a range. It is relevant only in case the macSrcAddr bit (4) in qosFlowMappingCriteria equals 1.
MAC qosFlowMappingFromDestMacAddr1.3.6.1.4.1.164.6.3.9.2.1.14MacAddressread-createThis attribute determines the first destination MAC address to compare with in a range. It is relevant only in case the macDestAddr (5) bit in qosFlowMappingCriteria equals 1.
MAC qosFlowMappingToDestMacAddr1.3.6.1.4.1.164.6.3.9.2.1.15MacAddressread-createThis attribute determines the last destination MAC address to compare with in a range. It is relevant only in case the macDestAddr (5) bit in qosFlowMappingCriteria equals 1.
IP qosFlowMappingFromSrcIpAddr1.3.6.1.4.1.164.6.3.9.2.1.16IpAddressread-createThis attribute determines the first source IP address to compare with in a range. It is relevant only in case the ipSrcAddr (6) bit in qosFlowMappingCriteria equals 1.
IP qosFlowMappingToSrcIpAddr1.3.6.1.4.1.164.6.3.9.2.1.17IpAddressread-createThis attribute determines the last source IP address to compare with in a range. It is relevant only in case the ipSrcAddr (6) bit in qosFlowMappingCriteria equals 1.
IP qosFlowMappingFromDestIpAddr1.3.6.1.4.1.164.6.3.9.2.1.18IpAddressread-createThis attribute determines the first destination IP address to compare with in a range. It is relevant only in case the ipDestAddr (7) bit in qosFlowMappingCriteria equals 1.
IP qosFlowMappingToDestIpAddr1.3.6.1.4.1.164.6.3.9.2.1.19IpAddressread-createThis attribute determines the last destination IP address to compare with in a range. It is relevant only in case the ipDestAddr (7) bit in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingFromTcpSrcPort1.3.6.1.4.1.164.6.3.9.2.1.20Unsigned32read-createThis attribute determines the first TCP source port to compare with in a range. It is relevant only in case the tcpSrcPort bit (8) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingToTcpSrcPort1.3.6.1.4.1.164.6.3.9.2.1.21Unsigned32read-createThis attribute determines the last TCP source port to compare with in a range. It is relevant only in case the tcpSrcPort bit (8) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingFromTcpDestPort1.3.6.1.4.1.164.6.3.9.2.1.22Unsigned32read-createThis attribute determines the first TCP destination port to compare with in a range. It is relevant only in case the tcpDestPort bit (9) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingToTcpDestPort1.3.6.1.4.1.164.6.3.9.2.1.23Unsigned32read-createThis attribute determines the last TCP destination port to compare with in a range. It is relevant only in case the tcpDestPort bit (9) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingFromUdpSrcPort1.3.6.1.4.1.164.6.3.9.2.1.24Unsigned32read-createThis attribute determines the first UDP source port to compare with in a range. It is relevant only in case the udpSrcPort bit (10) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingToUdpSrcPort1.3.6.1.4.1.164.6.3.9.2.1.25Unsigned32read-createThis attribute determines the last UDP source port to compare with in a range. It is relevant only in case the udpSrcPort bit (10) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingFromUdpDestPort1.3.6.1.4.1.164.6.3.9.2.1.26Unsigned32read-createThis attribute determines the first UDP destination port to compare with in a range. It is relevant only in case the udpDestPort bit (11) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingToUdpDestPort1.3.6.1.4.1.164.6.3.9.2.1.27Unsigned32read-createThis attribute determines the last UDP destination port to compare with in a range. It is relevant only in case the udpDestPort bit (11) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingFromIpPrecedence1.3.6.1.4.1.164.6.3.9.2.1.28Unsigned32read-createThis attribute determines the first IpPrecedence value to compare with in a range. It is relevant only in case the IpPrecedence bit (12) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingToIpPrecedence1.3.6.1.4.1.164.6.3.9.2.1.29Unsigned32read-createThis attribute determines the last IpPrecedence value to compare with in a range. It is relevant only in case the IpPrecedence bit (12) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingInnerIeee802dot1p1.3.6.1.4.1.164.6.3.9.2.1.30Unsigned32read-createThis attribute determines which TOS values are applicable for that flow. Each bit (0..7) represents a different inner 802.1 P-bit value. Setting '1' to the bit means that the corresponding inner 802.1 P-bit value is applicable. It is relevant only in case the innerIeee802dot1p bit (13) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingFromInnerVlanId1.3.6.1.4.1.164.6.3.9.2.1.31Unsigned32read-createThis attribute determines the first inner VLAN ID value to compare with in a range. It is relevant only in case the innerVlanId bit(14) in qosFlowMappingCriteria equals 1.
U32 qosFlowMappingToInnerVlanId1.3.6.1.4.1.164.6.3.9.2.1.32Unsigned32read-createThis attribute determines the last inner VLAN ID value to compare with in a range. It is relevant only in case the innerVlanId bit(14) in qosFlowMappingCriteria equals 1.
cosProfileTable1.3.6.1.4.1.164.6.3.10not-accessibleClass of Service Profile table. Each profile holds a priority method, and a mappring function that maps the priority values (range according to the method) into CoS values.
cosProfileEntry1.3.6.1.4.1.164.6.3.10.1not-accessibleA conceptual row where each row contains one CoS attributes.
U32 cosProfileIndex1.3.6.1.4.1.164.6.3.10.1.1Unsigned32not-accessibleDefines the CoS Profile ID.
ROW cosProfileRowStatus1.3.6.1.4.1.164.6.3.10.1.2RowStatusread-createThis attribute is used to create a new row or to delete an existing row in the table.
INT cosProfileCosMethod1.3.6.1.4.1.164.6.3.10.1.3INTEGERread-createDefines the priority method upon CoS mapping is done.
STR cosProfileName1.3.6.1.4.1.164.6.3.10.1.4SnmpAdminStringread-createThis attribute defines the name assigned to CoS profile.
OCT cosProfileCosMapping1.3.6.1.4.1.164.6.3.10.1.5OCTET STRINGread-createThis attribute defines the value of the CoS that is assigned for each priority. The number of the valid octets depends upon the priority method selected: Octet 0 corresponds to priority = 0 Octet 1 corresponds to priority = 1 ... Octet 63 corresponds to priority = 63.
queueProfileObjects1.3.6.1.4.1.164.6.3.11
qProfileTable1.3.6.1.4.1.164.6.3.11.1not-accessibleThis table defines the profiles for a cluster of queues.
qProfileEntry1.3.6.1.4.1.164.6.3.11.1.1not-accessibleA conceptual row where each row contains one Queue Cluster attribute.
U32 qProfileIndex1.3.6.1.4.1.164.6.3.11.1.1.1Unsigned32not-accessibleDefines the Queue Cluster Profile ID.
ROW qProfileRowStatus1.3.6.1.4.1.164.6.3.11.1.1.2RowStatusread-createThis attribute is used to create a new row or to delete an existing row in the table.
STR qProfileName1.3.6.1.4.1.164.6.3.11.1.1.3SnmpAdminStringread-createThis attribute holds the name of the Queue cluster profile.
U32 qProfileNumberOfInternalQ1.3.6.1.4.1.164.6.3.11.1.1.4Unsigned32read-createThis attribute holds the number of the internal queue profiles that are pointed by qInternalQProfile.
OCT qProfileInternalQProfile1.3.6.1.4.1.164.6.3.11.1.1.5OCTET STRINGread-createThis attribute holds the indexes to the queue profiles in the qInternalProfileTable. Each couple of octets holds an index to the qInternalProfileTable.
qInternalProfileTable1.3.6.1.4.1.164.6.3.11.2not-accessibleThis table holds queue profiles.
qInternalProfileEntry1.3.6.1.4.1.164.6.3.11.2.1not-accessibleA conceptual row where each row contains one Queue attribute.
U32 qInternalProfileIndex1.3.6.1.4.1.164.6.3.11.2.1.1Unsigned32not-accessibleDefines the Queue Profile ID.
ROW qInternalProfileRowStatus1.3.6.1.4.1.164.6.3.11.2.1.2RowStatusread-createThis attribute is used to create a new row or to delete an existing row in the table.
INT qInternalProfileScheduling1.3.6.1.4.1.164.6.3.11.2.1.3INTEGERread-createThis attribute determines the queue scheduling method.
U32 qInternalProfileWFQWeight1.3.6.1.4.1.164.6.3.11.2.1.4Unsigned32read-createThis attribute determines the weight that each WFQ (Weighted Fair Queue) participant gets. It is applicable only when scheduling is configured to WFQ.
U32 qInternalProfileQueueLength1.3.6.1.4.1.164.6.3.11.2.1.5Unsigned32read-createThis attribute determines the length of the queue.
U32 qInternalProfileWredStartDropThresh1.3.6.1.4.1.164.6.3.11.2.1.6Unsigned32read-createThis attribute determines the length that the queue (Start Value) must reach before the packets colored yellow will start being dropped by the WRED (Weighted Random Early Detection/Discard) mechanism. WRED is one the most commonly used method for congestion avoidance.
U32 qInternalProfileWredDropAllThresh1.3.6.1.4.1.164.6.3.11.2.1.7Unsigned32read-createThis attribute determines the length that the queue (Stop Value) must reach before the WRED (Weighted Random Early Detection) shaper mechanism stops dropping randomly, and just drops all further packets marked as yellow.
U32 qInternalProfileWredDropProbability1.3.6.1.4.1.164.6.3.11.2.1.8Unsigned32read-createThis attribute determines the percentage of packets that are being dropped at the point when the length of the queue reaches the Stop value. So, effectively, this defines how quickly the rate of dropping packet must increase as the queue length grows from the Start Value to the Stop Value.
U32 qInternalProfileRateLimit1.3.6.1.4.1.164.6.3.11.2.1.9Unsigned32read-createThis attribute determines the Rate Limit of the queue in Kbps. Value=0 represents best effort.
U32 qInternalProfileShaperProfile1.3.6.1.4.1.164.6.3.11.2.1.10Unsigned32read-createThis attribute defines the Shaper Profile (bwProfileIndex from bwProfileTable) assigned to this qInternalProfile. Valid range of bwProfileIndex for Shaper Profiles is 0x8000001-0x8000041. If set to '0', no profile is assigned to this qInternalProfile.
queueGroupTable1.3.6.1.4.1.164.6.3.11.3not-accessibleThis table defines the queue groups/blocks,their level and connections between them.
queueGroupEntry1.3.6.1.4.1.164.6.3.11.3.1not-accessibleA conceptual row where each row contains one Queue group.
STR queueGroupName1.3.6.1.4.1.164.6.3.11.3.1.1SnmpAdminStringnot-accessibleDefines the Queue Group unique name.
U32 queueGroupQBlockLevel1.3.6.1.4.1.164.6.3.11.3.1.2Unsigned32not-accessibleThis attribute holds the Level of the Queue Block .First level is 1. NA=2^32-1.
U32 queueGroupQBlockIdx1.3.6.1.4.1.164.6.3.11.3.1.3Unsigned32not-accessibleThis attribute holds the ID of the Queue Block. NA=2^32-1.
ROW queueGroupRowStatus1.3.6.1.4.1.164.6.3.11.3.1.4RowStatusread-createThis attribute is used to create a new row or to delete an existing row in the table.
U32 queueGroupQBlockProfile1.3.6.1.4.1.164.6.3.11.3.1.5Unsigned32read-createThis attribute defines the Queue profile assigned to this Queue Block. This object points to qProfileIndex in qProfileTable.
U32 queueGroupQBlockShaperProfile1.3.6.1.4.1.164.6.3.11.3.1.6Unsigned32read-createThis attribute defines the Shaper profile assigned to this Queue Block.
STR queueGroupPointToQBlock1.3.6.1.4.1.164.6.3.11.3.1.7SnmpAdminStringread-createThis attribute defines the Queue Block name of the next Queue Block level that is pointed by this Queue Block.
U32 queueGroupPointToInternalQueue1.3.6.1.4.1.164.6.3.11.3.1.8Unsigned32read-createThis attribute defines the internal queue whithin queueGroupPointToQBlock that is pointed by this Queue Block.
STR queueGroupQBlockName1.3.6.1.4.1.164.6.3.11.3.1.9SnmpAdminStringread-createThis attribute holds the name of the Queue Block.
markingProfileTable1.3.6.1.4.1.164.6.3.12not-accessibleMarking profile table. Each profile holds a marking function which converts CoS values to Service Provider priority values.
markingProfileEntry1.3.6.1.4.1.164.6.3.12.1not-accessibleA conceptual row where each row contains one Marking attribute.
U32 markingProfileIndex1.3.6.1.4.1.164.6.3.12.1.1Unsigned32not-accessibleDefines the Marking Profile ID.
ROW markingProfileRowStatus1.3.6.1.4.1.164.6.3.12.1.2RowStatusread-createThis attribute is used to create a new row or to delete an existing row in the table.
STR markingProfileName1.3.6.1.4.1.164.6.3.12.1.3SnmpAdminStringread-createThis attribute defines the unique name assigned to the Marking profile.
OCT markingSpVlanPBit1.3.6.1.4.1.164.6.3.12.1.4OCTET STRINGread-createFor ETX-202A : This attribute defines the value of the SP VLAN P-Bit that is assigned for each CoS: Octet 0 corresponds to CoS = 0 Octet 1 corresponds to CoS = 1 ... Octet 7 corresponds to CoS = 7. For LA-210 from V1.5 : This attribute defines the value of the SP VLAN P-Bit that is assigned for each frame according to the value of markingProfileMethod parameter : Octet 0 corresponds to value 0 of 802.1 P-bit/DSCP/TOS. Octet 1 corresponds to value 1 of 802.1 P-bit/DSCP/TOS. ... Octet 7 corresponds to value 7 of 802.1 P-bit/DSCP/TOS. Octets 8-63 correspond to DSCP values 8-63.
INT markingProfileMethod1.3.6.1.4.1.164.6.3.12.1.5INTEGERread-createThis attribute defines the method upon which marking is done.
radTransport1.3.6.1.4.1.164.6.4
radTransportDomains1.3.6.1.4.1.164.6.4.1
radTransportDomainSnmpEfmOam1.3.6.1.4.1.164.6.4.1.1The SNMP over EFM OAM transport domain. The corresponding transport address is of type RadTransportAddressEfmOam for EFM OAM addresses (port).
radStkHub1.3.6.1.4.1.164.7
radRouter1.3.6.1.4.1.164.11
rtrBridge1.3.6.1.4.1.164.11.7
webranger1.3.6.1.4.1.164.11.7.2
wrSysConfig1.3.6.1.4.1.164.11.7.2.1
INT wrBraodcastCtrlCmd1.3.6.1.4.1.164.11.7.2.1.1INTEGERread-writeThis parameter is a command to the webranger CPU. It enables blocking or forwarding broadcast frames, which may cause a trigger to a connection. block (1) - blocks the broadcast frames. forward (2) - forwards the broadcast frames. blockLinkPropagation (3) - blocks the broadcast frames to the links, tx to the LAN.
INT wrFrSelfLearningMode1.3.6.1.4.1.164.11.7.2.1.2INTEGERread-writeThis parameter enables the webranger to learn the DLCi's configuration and maintanance protocol. off - will get the configuration by setting it. on - disables configuration and start self learning.
INT wrGratuitousArp1.3.6.1.4.1.164.11.7.2.1.3INTEGERread-writeThis parameter enables/disables the Gratuitous ARP feature. When enabled, the feature means: when receiving ARP with sender's Source IP Address that already exists in the ARP table - replace MAC Address with sender's Source MAC Address.
wrIpRouterInfo1.3.6.1.4.1.164.11.7.2.2
wrConfigIpDhcp1.3.6.1.4.1.164.11.7.2.2.1
INT wrDhcpAction1.3.6.1.4.1.164.11.7.2.2.1.1INTEGERread-writeActivating (disable/enable) DHCP server operation. Since DHCP Server and DHCP Relay cannot reside in same device, DHCP Relay may be enabled (per interface), only if server action is disabled. For some devices, this object is used in order to enable/disable the DHCP Client. See device SDS.
wrDhcpTable1.3.6.1.4.1.164.11.7.2.2.1.2not-accessibleA list of DHCP entries. The number of entries is up to DHCP current entries, according to the WEBRANger model.
wrDhcpEntry1.3.6.1.4.1.164.11.7.2.2.1.2.1not-accessibleDHCP parameters per entry of the DHCP table.
IP wrDhcpLowIpAddress1.3.6.1.4.1.164.11.7.2.2.1.2.1.1IpAddressread-createDHCP Low Ip Address.
IP wrDhcpHighIpAddress1.3.6.1.4.1.164.11.7.2.2.1.2.1.2IpAddressread-createDHCP High Ip Address.
IP wrDhcpIpMaskAddress1.3.6.1.4.1.164.11.7.2.2.1.2.1.3IpAddressread-createIP mask Address.
IP wrDhcpDefaultGateway1.3.6.1.4.1.164.11.7.2.2.1.2.1.4IpAddressread-createDefault Gateway's IP Address.
IP wrDhcpPrimaryDNS1.3.6.1.4.1.164.11.7.2.2.1.2.1.5IpAddressread-createPrimary DNS.
IP wrDhcpSecondaryDNS1.3.6.1.4.1.164.11.7.2.2.1.2.1.6IpAddressread-createSecondary DNS.
INT wrDhcpInterface1.3.6.1.4.1.164.11.7.2.2.1.2.1.7INTEGERread-createThe IP addresse allocation is done according to the interface type from which the DHCP request arrives.
ROW wrDhcpRowStatus1.3.6.1.4.1.164.11.7.2.2.1.2.1.8RowStatusread-createThis attribute allows to create/delete a row in this table. For creating a row, the NMS should set wrDhcpRowStatus.id = active(1). For destroying a row, the NMS should set: wrDhcpStatus.id = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
I32 wrDhcpIpAddressLeaseTime1.3.6.1.4.1.164.11.7.2.2.1.2.1.9Integer32read-createAllocated IP Address lease time in seconds. A zero value specifies no time limitation.
STR wrDhcpPoolName1.3.6.1.4.1.164.11.7.2.2.1.2.1.10SnmpAdminStringread-createDHCP pool name - string with max length of 10 characters
IP wrDhcpTftpServerIp1.3.6.1.4.1.164.11.7.2.2.1.2.1.11IpAddressread-createDHCP pool - TFTP-server IP Address.
STR wrDhcpConfigFileName1.3.6.1.4.1.164.11.7.2.2.1.2.1.12SnmpAdminStringread-createTFTP-name of the configuration File Name for DHCP pool.
dhcpPoolAllocTable1.3.6.1.4.1.164.11.7.2.2.1.3not-accessibleA list of DHCP Pool Allocation entries. Each entry (row) consist of a single IP Address belonging to DHCP pool whose lowest IP address is dhcpPoolAllocLowIpAddress. This IP address may be offered for leasing, or may already be leased (in use) by Host it's MacAddress is dhcpPoolAllocMacAddress. Time left for leasing period is indicated by dhcpPoolAllocTimeLeft. All posible statuses of IP address are indicated and controlled by dhcpPoolAllocFlags
dhcpPoolAllocEntry1.3.6.1.4.1.164.11.7.2.2.1.3.1not-accessibleDHCP Pool Allocation parameters per entry of the DHCP Pool Allocation table.
IP dhcpPoolAllocLowIpAddress1.3.6.1.4.1.164.11.7.2.2.1.3.1.1IpAddressread-onlyLowest IP address of this pool, value eqaul to wrDhcpLowIpAddress for the pool.
IP dhcpPoolAllocLeasingIpAddress1.3.6.1.4.1.164.11.7.2.2.1.3.1.2IpAddressread-onlySingle IP Address belonging to dhcp pool whose Lowest Ip Address is dhcpPoolAllocLowIpAddress. This IP address may be offered for leasing or may be leased by Host its MacAddress is dhcpPoolAllocMacAddress. All posible statuses of IP address are indicated by dhcpPoolAllocFlags
MAC dhcpPoolAllocMacAddress1.3.6.1.4.1.164.11.7.2.2.1.3.1.3MacAddressread-onlyMAC Address to which the IP address has been leased
I32 dhcpPoolAllocTimeLeft1.3.6.1.4.1.164.11.7.2.2.1.3.1.4Integer32read-onlyIP address leasing time left in seconds
INT dhcpPoolAllocFlags1.3.6.1.4.1.164.11.7.2.2.1.3.1.5INTEGERread-onlyThese flags indicates status of each IP address. User may change value to free, via dhcpPoolAllocFreeCmd
INT dhcpPoolAllocFreeCmd1.3.6.1.4.1.164.11.7.2.2.1.3.1.6INTEGERread-writeSetting this attribute to On (3), will enforce the agent to Free this entry. The Agent will change the value of this MIB object to off(2) automatically, after performing the command. Setting this object to off(2), will do nothing
dhcpRelayTable1.3.6.1.4.1.164.11.7.2.2.1.4not-accessibleA list of DHCP relay entries.
dhcpRelayEntry1.3.6.1.4.1.164.11.7.2.2.1.4.1not-accessibleDHCP Relay parameters per entry of the DHCP relay table.
INT dhcpRelayAction1.3.6.1.4.1.164.11.7.2.2.1.4.1.1INTEGERread-writeSetting this attribute to enable (3), will enable DHCP Relay action for this interface (Only if DHCP Server is disabled for device - wrDhcpAction=disable). dhcpRelayServerIpAddressaddress should not be 0.0.0.0 when enable is set
IP dhcpRelayServerIpAddress1.3.6.1.4.1.164.11.7.2.2.1.4.1.2IpAddressread-writeDHCP Server IP Address.
I32 dhcpRelayMaxHop1.3.6.1.4.1.164.11.7.2.2.1.4.1.3Integer32read-writeMaximum number of hops till DHCP Server. upper limit is 16 hops
INT wrDhcpPort1.3.6.1.4.1.164.11.7.2.2.1.5INTEGERread-writeThis parameter defines the port that DHCP flow will be actiavted.
dhcpClientTable1.3.6.1.4.1.164.11.7.2.2.1.6not-accessibleA list of DHCP client entries.
dhcpClientEntry1.3.6.1.4.1.164.11.7.2.2.1.6.1not-accessibleDHCP Client parameters per entry of the DHCP Client table.
INT dhcpClientAction1.3.6.1.4.1.164.11.7.2.2.1.6.1.1INTEGERread-writeThis parameter default value is enable(3). Setting this attribute to disable (2), will disable DHCP Client action for this interface. This parameter can be changed to disable (2) only (it cannot be changed from disable to enable).
IP dhcpClientServerIpAddress1.3.6.1.4.1.164.11.7.2.2.1.6.1.2IpAddressread-writeDHCP Server IP Address.
I32 dhcpClientLeaseExpirationTime1.3.6.1.4.1.164.11.7.2.2.1.6.1.3Integer32read-onlyThis parameter holds the time (in minutes) left until lease expiration.
STR dhcpClientStatus1.3.6.1.4.1.164.11.7.2.2.1.6.1.4DisplayStringread-onlyThis parametr displays the DHCP status.
dhcpIfClientTable1.3.6.1.4.1.164.11.7.2.2.1.7not-accessibleDHCP client entries for each Interface.
dhcpIfClientEntry1.3.6.1.4.1.164.11.7.2.2.1.7.1not-accessibleDHCP Clients per entry of the DHCP Interface Client table.
IP dhcpIfClientIpAddress1.3.6.1.4.1.164.11.7.2.2.1.7.1.2IpAddressread-createDHCP Client IP Address.
ROW dhcpIfClientRowStatus1.3.6.1.4.1.164.11.7.2.2.1.7.1.3RowStatusread-createThe row status used for creating, modifying, and deleting instances of the columnar objects in the dhcpIfClientTable. For Vmux Devices, it will be possible only to Delete instances. The addition of Clients will be done automatically by the Server according to Network messages that are sent by the Clients; not via SNMP. In order to Delete a Client, this MIB object should be set to: destroy (6).
INT dhcpServerAction1.3.6.1.4.1.164.11.7.2.2.1.8INTEGERread-writeThis variable enables the operator to perform one of the specified actions on the Server. deleteAllClients (3) is an option that is used for a device functioning as a server. It will remove all the clients from all the interfaces of the device. When the operation is complete, the agent will return a noOp (2) value.
wrConfigIpDNS1.3.6.1.4.1.164.11.7.2.2.2
INT wrDNSRelayAction1.3.6.1.4.1.164.11.7.2.2.2.1INTEGERread-writeWhen Enabled, device will act as a DNS Relay: whenever the device receives a DNS request from its host, it will forward it to the DNS server as if the request was initiated by the device itself. The reply from the DNS server is forwarded by the device to the host as if the device was answering the request.
wrConfigIpxRouterInfo1.3.6.1.4.1.164.11.7.2.3
INT wrAutoLearnLanIpxNets1.3.6.1.4.1.164.11.7.2.3.1INTEGERread-writeActivating (disable/enable) the auto-learn operation.
wrLanIpxNetTable1.3.6.1.4.1.164.11.7.2.3.2not-accessibleLan IPX nets Table.
wrLanIpxNetEntry1.3.6.1.4.1.164.11.7.2.3.2.1not-accessibleIPX Nets per frame type & LAN port. The table entries will be created by the agent
I32 wrLanIfIndex1.3.6.1.4.1.164.11.7.2.3.2.1.1Integer32read-onlyLAN port ifIndex.
INT wrLanIpxFrameType1.3.6.1.4.1.164.11.7.2.3.2.1.2INTEGERread-onlyFrame Type
IP wrIpxNetAddress1.3.6.1.4.1.164.11.7.2.3.2.1.3IpAddressread-writeNet address per Frame Type & LAN port.
IP wrDialInIpxNet1.3.6.1.4.1.164.11.7.2.3.3IpAddressread-writeNet address through a link.
ripSapIfConfTable1.3.6.1.4.1.164.11.7.2.3.4not-accessibleA list of Interfaces which require separate configuration in RIP/SAP.
ripSapIfConfEntry1.3.6.1.4.1.164.11.7.2.3.4.1not-accessibleA Single Routing Domain in a single Subnet.
I32 ripSapIfConfIfIndex1.3.6.1.4.1.164.11.7.2.3.4.1.1Integer32read-onlyThe interface ifIndex.
INT ripSapIfConfMode1.3.6.1.4.1.164.11.7.2.3.4.1.2INTEGERread-createThe ifIndex RIP/SAP mode.
ROW ripSapIfConfStatus1.3.6.1.4.1.164.11.7.2.3.4.1.3RowStatusread-createThis attribute allows to create/delete a row in this table. For creating a row, the NMS should set ripSapIfConfStatus.id1 = active(1). For destroying a row, the NMS should set: ripSapIfConfStatus.id1 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
wrInterface1.3.6.1.4.1.164.11.7.2.4
wrIpAddressTable1.3.6.1.4.1.164.11.7.2.4.1not-accessibleLink IP addresses Table.
wrIpAddressEntry1.3.6.1.4.1.164.11.7.2.4.1.1not-accessibleIp Address per Link
I32 wrIpIfIndex1.3.6.1.4.1.164.11.7.2.4.1.1.1Integer32read-onlyPort interface index.
IP wrIpAddress1.3.6.1.4.1.164.11.7.2.4.1.1.2IpAddressread-createLink IP Address.
IP wrIpMask1.3.6.1.4.1.164.11.7.2.4.1.1.3IpAddressread-createLink IP mask Address.
ROW wrIpRowStatus1.3.6.1.4.1.164.11.7.2.4.1.1.4RowStatusread-createThis attribute allows to create/delete a row in this table. For creating a row, the NMS should set wrIpRowStatus.id1 = active(1). For destroying a row, the NMS should set: wrIpRowStatus.id1 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
wrSpoofingTable1.3.6.1.4.1.164.11.7.2.4.2not-accessibleSpoofing Table.
wrSpoofingEntry1.3.6.1.4.1.164.11.7.2.4.2.1not-accessibleSpoofing per Link
I32 wrSpoofingIfIndex1.3.6.1.4.1.164.11.7.2.4.2.1.1Integer32read-onlyPort interface index.
I32 wrSpoofingAction1.3.6.1.4.1.164.11.7.2.4.2.1.2Integer32read-createSpoofing action is applied by bit code: enable : bit 0 set (disable: bit 0 is 0) keepAlive : bit 1 ... : bit 2 and so on. For the above example, to set spoofing to keepAlive action, the object's value will be 3 = [ 2**0 + 2**1 ] Only the Remote WEBRANger will accept this object ! -------
I32 wrSpoofingAgingStation1.3.6.1.4.1.164.11.7.2.4.2.1.3Integer32read-createAging time of stations list, in min. The agent 'translates' the time entered in minutes, to 10 min. resolution, as follows: 1..10 min - 10 min 11..20 min - 20 min and so on... 0 is not a valid value. Only the Remote WEBRANger will accept this object ! ----------------
ROW wrSpoofingRowStatus1.3.6.1.4.1.164.11.7.2.4.2.1.4RowStatusread-createThis attribute allows to create/delete a row in this table. For creating a row, the NMS should set wrSpoofingRowStatus.id1 = active(1). For destroying a row, the NMS should set: wrSpoofingRowStatus.id1 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
wrLanIfTable1.3.6.1.4.1.164.11.7.2.4.3not-accessibleLink IP addresses Table.
wrLanIfEntry1.3.6.1.4.1.164.11.7.2.4.3.1not-accessibleIp Address per Link
INT wrLanBridgeRouterMode1.3.6.1.4.1.164.11.7.2.4.3.1.2INTEGERread-writeThis parameter indicates whether the link is Bridge or Router and specifies the Router's type.
INT wrLanIfState1.3.6.1.4.1.164.11.7.2.4.3.1.3INTEGERread-writeThe LAN is disabled or enabled. For LAN 2 it can be also 'redundancy'.
I32 wrLanIfRdnTimeout1.3.6.1.4.1.164.11.7.2.4.3.1.4Integer32read-writeLAN Redundancy Timeout in seconds. Applicable when wrLanIfState=redundancy.
wrSyncCnfgTable1.3.6.1.4.1.164.11.7.2.4.4not-accessibleConfiguration table for Async interface.
wrSyncCnfgEntry1.3.6.1.4.1.164.11.7.2.4.4.1not-accessibleConfiguration table
I32 wrSyncIfIndex1.3.6.1.4.1.164.11.7.2.4.4.1.1Integer32read-onlySync interface index.
INT wrSyncClkMode1.3.6.1.4.1.164.11.7.2.4.4.1.2INTEGERread-writeClock Mode.
INT wrSyncClkRate1.3.6.1.4.1.164.11.7.2.4.4.1.3INTEGERread-writeClock Rate in. Rate can be changed if Clock Mode is Program only.
wrFrCnfgTable1.3.6.1.4.1.164.11.7.2.4.5not-accessibleConfiguration table for Fr parameters that do not exist in RFC2115.
wrFrCnfgEntry1.3.6.1.4.1.164.11.7.2.4.5.1not-accessibleConfiguration entry for Fr parameters that do not exist in RFC2115.
INT wrFrDlciLearningMode1.3.6.1.4.1.164.11.7.2.4.5.1.1INTEGERread-writeThis parameter enables the webranger to learn the DLCi's configuration and maintanance protocol for the current interface. off - the WR will read the user's configuration for this interface. on - the WR will begin self learning of the current interface's maintanance protocol and DLCIs.
INT wrFrCllmMessages1.3.6.1.4.1.164.11.7.2.4.5.1.2INTEGERread-writeThis parameter enables/disables the Webranger to Tx/Rx CLLM (Consolidated Link Layer Management) messages via DLCI 1023. The CLLM messages are link layer control messages. They can be used for example in cases of congestion. The CLLM message contains a code for cause of congestion and list of all DLCIs that should act to reduce data transmission.
radAtm1.3.6.1.4.1.164.12
atmGen1.3.6.1.4.1.164.12.2
atmPerfHistory1.3.6.1.4.1.164.12.2.1
atmIfPerformance1.3.6.1.4.1.164.12.2.1.1
atmIfDataTable1.3.6.1.4.1.164.12.2.1.1.1not-accessibleThe ATM interface Data table.
atmIfDataEntry1.3.6.1.4.1.164.12.2.1.1.1.1not-accessibleAn entry in the ATM interface Data table.
I32 atmIfTimeElapsed1.3.6.1.4.1.164.12.2.1.1.1.1.1Integer32read-onlyThe number of seconds that have elapsed since the beginning of the near end current error- measurement period.
I32 atmIfValidIntervals1.3.6.1.4.1.164.12.2.1.1.1.1.2Integer32read-onlyThe number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online.
C32 atmIfTxCells1.3.6.1.4.1.164.12.2.1.1.1.1.3Counter32read-onlyThe counter associated with the total number of transmitted cells, encountered by an ATM interface.
C32 atmIfRxCells1.3.6.1.4.1.164.12.2.1.1.1.1.4Counter32read-onlyThe counter associated with the total number of received cells, encountered by an ATM interface.
C32 atmIfUncorrectedHecs1.3.6.1.4.1.164.12.2.1.1.1.1.5Counter32read-onlyThe counter associated with the total number of cells with uncorrected HEC errors, encountered by an ATM interface.
atmIfCurrentTable1.3.6.1.4.1.164.12.2.1.1.2not-accessibleThe ATM interface Current table.
atmIfCurrentEntry1.3.6.1.4.1.164.12.2.1.1.2.1not-accessibleAn entry in the ATM interface Current table.
G32 atmIfCurrentTxCells1.3.6.1.4.1.164.12.2.1.1.2.1.1Gauge32read-onlyThe counter associated with the number of transmitted cells, encountered by an ATM interface in the current 15 minute interval.
G32 atmIfCurrentRxCells1.3.6.1.4.1.164.12.2.1.1.2.1.2Gauge32read-onlyThe counter associated with the number of received cells, encountered by an ATM interface in the current 15 minute interval.
G32 atmIfCurrentCorrectedHecs1.3.6.1.4.1.164.12.2.1.1.2.1.3Gauge32read-onlyThe counter associated with the number of cells with corrected HEC errors, encountered by an ATM interface in the current 15 minute interval.
G32 atmIfCurrentUncorrectedHecs1.3.6.1.4.1.164.12.2.1.1.2.1.4Gauge32read-onlyThe counter associated with the number of cells with uncorrected HEC errors, encountered by an ATM interface in the current 15 minute interval.
G32 atmIfCurrentHecErrorSeconds1.3.6.1.4.1.164.12.2.1.1.2.1.5Gauge32read-onlyThe counter associated with the number of seconds with HEC errors, encountered by an ATM interface in the current 15 minute interval.
atmIfIntervalTable1.3.6.1.4.1.164.12.2.1.1.3not-accessibleThe ATM interface Interval table.
atmIfIntervalEntry1.3.6.1.4.1.164.12.2.1.1.3.1not-accessibleAn entry in the ATM interface Interval table.
I32 atmIfIntervalNumber1.3.6.1.4.1.164.12.2.1.1.3.1.1Integer32read-onlyA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
G32 atmIfIntervalTxCells1.3.6.1.4.1.164.12.2.1.1.3.1.2Gauge32read-onlyThe counter associated with the number of transmitted cells , encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
G32 atmIfIntervalRxCells1.3.6.1.4.1.164.12.2.1.1.3.1.3Gauge32read-onlyThe counter associated with the number of received cells, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
G32 atmIfIntervalCorrectedHecs1.3.6.1.4.1.164.12.2.1.1.3.1.4Gauge32read-onlyThe counter associated with the number of cells with corrected HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
G32 atmIfIntervalUncorrectedHecs1.3.6.1.4.1.164.12.2.1.1.3.1.5Gauge32read-onlyThe counter associated with the number of cells with uncorrected HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
G32 atmIfIntervalHecErrorSeconds1.3.6.1.4.1.164.12.2.1.1.3.1.6Gauge32read-onlyThe counter associated with the number of seconds with HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
atmPvcPerformance1.3.6.1.4.1.164.12.2.1.2
atmVpPerformance1.3.6.1.4.1.164.12.2.1.2.1
atmVpCurrentTable1.3.6.1.4.1.164.12.2.1.2.1.1not-accessibleThe ATM VP Current table.
atmVpCurrentEntry1.3.6.1.4.1.164.12.2.1.2.1.1.1not-accessibleAn entry in the ATM VP Current table.
I32 atmVpCurrentVpi1.3.6.1.4.1.164.12.2.1.2.1.1.1.1Integer32read-onlyThe VPI of the VPL.
G32 atmVpCurrentRxCellsClp011.3.6.1.4.1.164.12.2.1.2.1.1.1.2Gauge32read-onlyThe counter associated with the number of transmitted cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpCurrentRxCellsClp01.3.6.1.4.1.164.12.2.1.2.1.1.1.3Gauge32read-onlyThe counter associated with the number of received cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpCurrentGcra0Violations1.3.6.1.4.1.164.12.2.1.2.1.1.1.4Gauge32read-onlyThe counter associated with the number of cells violating GCRA0, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpCurrentGcra1Violations1.3.6.1.4.1.164.12.2.1.2.1.1.1.5Gauge32read-onlyThe counter associated with the number of cells violating GCRA1, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpCurrentRxAIS1.3.6.1.4.1.164.12.2.1.2.1.1.1.6Gauge32read-onlyThe counter associated with the number of received AIS cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpCurrentTxAIS1.3.6.1.4.1.164.12.2.1.2.1.1.1.7Gauge32read-onlyThe counter associated with the number of transmitted AIS cells, encountered by the VPL of this ATM interface in the current 15 minute interval. Not Supported in the first phase.
G32 atmVpCurrentRxRDI1.3.6.1.4.1.164.12.2.1.2.1.1.1.8Gauge32read-onlyThe counter associated with the number of received RDI cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpCurrentTxRDI1.3.6.1.4.1.164.12.2.1.2.1.1.1.9Gauge32read-onlyThe counter associated with the number of transmitted RDI cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpCurrentContinuityLoss1.3.6.1.4.1.164.12.2.1.2.1.1.1.10Gauge32read-onlyThe counter associated with the number of loss of continuity cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpCurrentUAS1.3.6.1.4.1.164.12.2.1.2.1.1.1.11Gauge32read-onlyThe counter associated with the number of Unavailable Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpCurrentSES1.3.6.1.4.1.164.12.2.1.2.1.1.1.12Gauge32read-onlyThe counter associated with the number of Severerly Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpCurrentCDC1.3.6.1.4.1.164.12.2.1.2.1.1.1.13Gauge32read-onlyAmount of cells dropped in the current 15 minute interval of the VP connection.
G32 atmVpCurrentTotalDiscards1.3.6.1.4.1.164.12.2.1.2.1.1.1.14Gauge32read-onlyThe total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
G32 atmVpCurrentClp0Discards1.3.6.1.4.1.164.12.2.1.2.1.1.1.15Gauge32read-onlyThe total number of valid ATM cells received with CLP=0 and discarded by the traffic policing entity.
G32 atmVpCurrentTotalCellOuts1.3.6.1.4.1.164.12.2.1.2.1.1.1.16Gauge32read-onlyThe total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
G32 atmVpCurrentClp0CellOuts1.3.6.1.4.1.164.12.2.1.2.1.1.1.17Gauge32read-onlyThe total number of valid ATM cells transmitted with CLP=0 by this VPL.
G32 atmVpCurrentTaggedOuts1.3.6.1.4.1.164.12.2.1.2.1.1.1.18Gauge32read-onlyThe total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
G32 atmVpCurrentPCR1.3.6.1.4.1.164.12.2.1.2.1.1.1.19Gauge32read-onlyThe maximum traffic rate encountered in the last interval of the VP connection (monitored once a second).
G32 atmVpCurrentSCR1.3.6.1.4.1.164.12.2.1.2.1.1.1.20Gauge32read-onlyThe average traffic rate during the last interval of the VP connection.
G32 atmVpCurrentMCR1.3.6.1.4.1.164.12.2.1.2.1.1.1.21Gauge32read-onlyMCR - The minimum traffic rate encountered in the last interval of the VP connection (monitored once a second).
G32 atmVpCurrentShaperTotalDiscards1.3.6.1.4.1.164.12.2.1.2.1.1.1.22Gauge32read-onlyThe total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
G32 atmVpCurrentShaperClp0Discards1.3.6.1.4.1.164.12.2.1.2.1.1.1.23Gauge32read-onlyThe total number of CLP0 cells discarded due to congestion by the traffic shaper.
G32 atmVpCurrentShaperClp1Discards1.3.6.1.4.1.164.12.2.1.2.1.1.1.24Gauge32read-onlyThe total number of CLP1 cells discarded due to congestion by the traffic shaper.
atmVpPMCurrentTable1.3.6.1.4.1.164.12.2.1.2.1.2not-accessibleThe ATM VP Current table for Performance Management.
atmVpPMCurrentEntry1.3.6.1.4.1.164.12.2.1.2.1.2.1not-accessibleAn entry in the ATM VP Current table for Performance Management.
I32 atmVpPMCurrentVpi1.3.6.1.4.1.164.12.2.1.2.1.2.1.1Integer32read-onlyThe VPI of the VPL.
INT atmVpPMCurrentDir1.3.6.1.4.1.164.12.2.1.2.1.2.1.2INTEGERread-onlyThe direction of performance management.
G32 atmVpPMCurrentTxClp011.3.6.1.4.1.164.12.2.1.2.1.2.1.3Gauge32read-onlyThe counter associated with the number of transmitted CLP 0+1 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpPMCurrentTxClp01.3.6.1.4.1.164.12.2.1.2.1.2.1.4Gauge32read-onlyThe counter associated with the number of transmitted CLP 0 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpPMCurrentRxClp011.3.6.1.4.1.164.12.2.1.2.1.2.1.5Gauge32read-onlyThe counter associated with the number of received CLP 0+1 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpPMCurrentRxClp01.3.6.1.4.1.164.12.2.1.2.1.2.1.6Gauge32read-onlyThe counter associated with the number of received CLP 0 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpPMCurrentErroredCells1.3.6.1.4.1.164.12.2.1.2.1.2.1.7Gauge32read-onlyThe counter associated with the number of errored cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpPMCurrentLostCells1.3.6.1.4.1.164.12.2.1.2.1.2.1.8Gauge32read-onlyThe counter associated with the number of lost cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpPMCurrentMisinsertedCells1.3.6.1.4.1.164.12.2.1.2.1.2.1.9Gauge32read-onlyThe counter associated with the number of misinserted cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpPMCurrentECB1.3.6.1.4.1.164.12.2.1.2.1.2.1.10Gauge32read-onlyThe counter associated with the number of ECB, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpPMCurrentSECB1.3.6.1.4.1.164.12.2.1.2.1.2.1.11Gauge32read-onlyThe counter associated with the number of SECB, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpPMCurrentES1.3.6.1.4.1.164.12.2.1.2.1.2.1.12Gauge32read-onlyThe counter associated with the number of Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpPMCurrentSES1.3.6.1.4.1.164.12.2.1.2.1.2.1.13Gauge32read-onlyThe counter associated with the number of Severely Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
G32 atmVpPMCurrentUAS1.3.6.1.4.1.164.12.2.1.2.1.2.1.14Gauge32read-onlyThe counter associated with the number of Unavailable Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
INT atmVpPMCurrentIntervalQuality1.3.6.1.4.1.164.12.2.1.2.1.2.1.15INTEGERread-onlyIf the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
INT atmVpPMCurrentLastDayQuality1.3.6.1.4.1.164.12.2.1.2.1.2.1.16INTEGERread-onlyIf the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
atmVpIntervalTable1.3.6.1.4.1.164.12.2.1.2.1.3not-accessibleThe ATM Vp Interval table.
atmVpIntervalEntry1.3.6.1.4.1.164.12.2.1.2.1.3.1not-accessibleAn entry in the ATM Vp Interval table.
I32 atmVpIntervalVpi1.3.6.1.4.1.164.12.2.1.2.1.3.1.1Integer32read-onlyThe VPI of the VPL.
I32 atmVpIntervalNumber1.3.6.1.4.1.164.12.2.1.2.1.3.1.2Integer32read-onlyA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
G32 atmVpIntervalRxCellsClp011.3.6.1.4.1.164.12.2.1.2.1.3.1.3Gauge32read-onlyThe counter associated with the number of transmitted cells , encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalRxCellsClp01.3.6.1.4.1.164.12.2.1.2.1.3.1.4Gauge32read-onlyThe counter associated with the number of received cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalGcra0Violations1.3.6.1.4.1.164.12.2.1.2.1.3.1.5Gauge32read-onlyThe counter associated with the number of cells violating GCRA0, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalGcra1Violations1.3.6.1.4.1.164.12.2.1.2.1.3.1.6Gauge32read-onlyThe counter associated with the number of cells violating GCRA1, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalRxAIS1.3.6.1.4.1.164.12.2.1.2.1.3.1.7Gauge32read-onlyThe counter associated with the number of received AIS cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalTxAIS1.3.6.1.4.1.164.12.2.1.2.1.3.1.8Gauge32read-onlyThe counter associated with the number of transmitted AIS cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals. Not supported in the first phase.
G32 atmVpIntervalRxRDI1.3.6.1.4.1.164.12.2.1.2.1.3.1.9Gauge32read-onlyThe counter associated with the number of received RDI cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalTxRDI1.3.6.1.4.1.164.12.2.1.2.1.3.1.10Gauge32read-onlyThe counter associated with the number of transmitted RDI cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalContinuityLoss1.3.6.1.4.1.164.12.2.1.2.1.3.1.11Gauge32read-onlyThe counter associated with the number of Continuity Loss cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalUAS1.3.6.1.4.1.164.12.2.1.2.1.3.1.12Gauge32read-onlyThe counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalSES1.3.6.1.4.1.164.12.2.1.2.1.3.1.13Gauge32read-onlyThe counter associated with the number of Severerly Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalCDC1.3.6.1.4.1.164.12.2.1.2.1.3.1.14Gauge32read-onlyAmount of cells dropped in the 15 minute interval of the VP connection.
G32 atmVpIntervalTotalDiscards1.3.6.1.4.1.164.12.2.1.2.1.3.1.15Gauge32read-onlyThe total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
G32 atmVpIntervalClp0Discards1.3.6.1.4.1.164.12.2.1.2.1.3.1.16Gauge32read-onlyThe total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity.
G32 atmVpIntervalTotalCellOuts1.3.6.1.4.1.164.12.2.1.2.1.3.1.17Gauge32read-onlyThe total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
G32 atmVpIntervalClp0CellOuts1.3.6.1.4.1.164.12.2.1.2.1.3.1.18Gauge32read-onlyThe total number of valid ATM cells transmitted with CLP=0 by this VPL.
G32 atmVpIntervalTaggedOuts1.3.6.1.4.1.164.12.2.1.2.1.3.1.19Gauge32read-onlyThe total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
G32 atmVpIntervalPCR1.3.6.1.4.1.164.12.2.1.2.1.3.1.20Gauge32read-onlyThe maximum traffic rate encountered in the last interval of the VP connection (monitored once a second) encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalSCR1.3.6.1.4.1.164.12.2.1.2.1.3.1.21Gauge32read-onlyThe average traffic rate during the last interval of the VP connection , encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalMCR1.3.6.1.4.1.164.12.2.1.2.1.3.1.22Gauge32read-onlyMCR - The minimum traffic rate encountered in the last interval of the VP connection (monitored once a second) encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpIntervalShaperTotalDiscards1.3.6.1.4.1.164.12.2.1.2.1.3.1.23Gauge32read-onlyThe total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
G32 atmVpIntervalShaperClp0Discards1.3.6.1.4.1.164.12.2.1.2.1.3.1.24Gauge32read-onlyThe total number of CLP0 cells discarded due to congestion by the traffic shaper.
G32 atmVpIntervalShaperClp1Discards1.3.6.1.4.1.164.12.2.1.2.1.3.1.25Gauge32read-onlyThe total number of CLP1 cells discarded due to congestion by the traffic shaper.
atmVpPMIntervalTable1.3.6.1.4.1.164.12.2.1.2.1.4not-accessibleThe ATM Vp Interval table for Performance Management.
atmVpPMIntervalEntry1.3.6.1.4.1.164.12.2.1.2.1.4.1not-accessibleAn entry in the ATM Vp Interval table for Performance Management.
I32 atmVpPMIntervalVpi1.3.6.1.4.1.164.12.2.1.2.1.4.1.1Integer32read-onlyThe VPI of the VPL.
INT atmVpPMIntervalDir1.3.6.1.4.1.164.12.2.1.2.1.4.1.2INTEGERread-onlyThe direction of performance management.
I32 atmVpPMIntervalNumber1.3.6.1.4.1.164.12.2.1.2.1.4.1.3Integer32read-onlyA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
G32 atmVpPMIntervalTxClp011.3.6.1.4.1.164.12.2.1.2.1.4.1.4Gauge32read-onlyThe counter associated with the number of transmitted CLP 0+1 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpPMIntervalTxClp01.3.6.1.4.1.164.12.2.1.2.1.4.1.5Gauge32read-onlyThe counter associated with the number of transmitted CLP 0 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpPMIntervalRxClp011.3.6.1.4.1.164.12.2.1.2.1.4.1.6Gauge32read-onlyThe counter associated with the number of received CLP 0+1 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpPMIntervalRxClp01.3.6.1.4.1.164.12.2.1.2.1.4.1.7Gauge32read-onlyThe counter associated with the number of received CLP 0 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpPMIntervalErroredCells1.3.6.1.4.1.164.12.2.1.2.1.4.1.8Gauge32read-onlyThe counter associated with the number of Errored cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpPMIntervalLostCells1.3.6.1.4.1.164.12.2.1.2.1.4.1.9Gauge32read-onlyThe counter associated with the number of Lost cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpPMIntervalMisinsertedCells1.3.6.1.4.1.164.12.2.1.2.1.4.1.10Gauge32read-onlyThe counter associated with the number of Misinserted cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpPMIntervalECB1.3.6.1.4.1.164.12.2.1.2.1.4.1.11Gauge32read-onlyThe counter associated with the number of ECBs encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpPMIntervalSECB1.3.6.1.4.1.164.12.2.1.2.1.4.1.12Gauge32read-onlyThe counter associated with the number of SECBs encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpPMIntervalES1.3.6.1.4.1.164.12.2.1.2.1.4.1.13Gauge32read-onlyThe counter associated with the number of Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpPMIntervalSES1.3.6.1.4.1.164.12.2.1.2.1.4.1.14Gauge32read-onlyThe counter associated with the number of Severely Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
G32 atmVpPMIntervalUAS1.3.6.1.4.1.164.12.2.1.2.1.4.1.15Gauge32read-onlyThe counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
INT atmVpPMIntervalQuality1.3.6.1.4.1.164.12.2.1.2.1.4.1.16INTEGERread-onlyIf the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
INT atmVpPMIntervalLastDayQuality1.3.6.1.4.1.164.12.2.1.2.1.4.1.17INTEGERread-onlyIf the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
atmVpQoSTable1.3.6.1.4.1.164.12.2.1.2.1.5not-accessibleThe VP QoS table.
atmVpQoSEntry1.3.6.1.4.1.164.12.2.1.2.1.5.1not-accessible.
INT atmVpQoSPeriodRef1.3.6.1.4.1.164.12.2.1.2.1.5.1.1INTEGERread-onlyThis object is an index that specifies which period of time, the next 2 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
I32 atmVpQoSElapsedTime1.3.6.1.4.1.164.12.2.1.2.1.5.1.2Integer32read-onlyElapsed Time in seconds. - for atmVpQoSPeriodRef = currentPeriod: The period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. - for atmVpQoSPeriodRef = lastPeriod: The value of atmVpQoSElapsedTime when last systemResetAllStatsCmd was received.
G32 atmVpQoSUAS1.3.6.1.4.1.164.12.2.1.2.1.5.1.3Gauge32read-onlyNumber of Unavailable Seconds for the reference period (atmVpQoSPeriodRef).
atmVpPMQoSTable1.3.6.1.4.1.164.12.2.1.2.1.6not-accessibleThe PM VP QoS table.
atmVpPMQoSEntry1.3.6.1.4.1.164.12.2.1.2.1.6.1not-accessible.
INT atmVpPMQoSDirection1.3.6.1.4.1.164.12.2.1.2.1.6.1.1INTEGERread-onlyThe direction of performance management.
INT atmVpPMQoSPeriodRef1.3.6.1.4.1.164.12.2.1.2.1.6.1.2INTEGERread-onlyThis object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
G32 atmVpPMQoSCLR1.3.6.1.4.1.164.12.2.1.2.1.6.1.3Gauge32read-onlyCell Loss Ratio counter for the reference period (atmVpPMQoSPeriodRef)- defined in accordance with I.356 , in %. The value will be multipuled by 100.
G32 atmVpPMQoSCER1.3.6.1.4.1.164.12.2.1.2.1.6.1.4Gauge32read-onlyCell Error Ratio counter for the reference period (atmVpPMQoSPeriodRef) defined in accordance with I.356 , in %. The value will be multipuled by 100.
G32 atmVpPMQoSCMR1.3.6.1.4.1.164.12.2.1.2.1.6.1.5Gauge32read-onlyCell Misinsertion Ratio counter for the reference period (atmVpPMQoSPeriodRef) defined in accordance with I.356 , cells/sec .
atmVpShaperStatTable1.3.6.1.4.1.164.12.2.1.2.1.7not-accessibleThe ATM VP shaper statistics table.
atmVpShaperStatEntry1.3.6.1.4.1.164.12.2.1.2.1.7.1not-accessibleAn entry in the ATM VP shaper statistics table.
C32 atmVpShaperDiscarded1.3.6.1.4.1.164.12.2.1.2.1.7.1.1Counter32read-onlyThe number of Cells that were discarded in the shaper on that VPC due to buffer overflow. This counter counts till it reaches its MAX value (20 bits) and then rolls over.
I32 atmVpShaperOccupation1.3.6.1.4.1.164.12.2.1.2.1.7.1.2Integer32read-onlyThe number of Cells that are currently stored in the buffer. This parameter is limited to 20 bits.
I32 atmVpShaperMaxOccupation1.3.6.1.4.1.164.12.2.1.2.1.7.1.3Integer32read-onlyThe Maximum number of Cells that were stored in the buffer, since this VP was activated. This parameter is limited to 20 bits.
INT atmVpShaperLevel1.3.6.1.4.1.164.12.2.1.2.1.7.1.4INTEGERread-onlyThe occupation of the buffer according to a predefined threshold. empty - buffer is Empty full - buffer is Full below - buffer is Below the threshold above - buffer is Above the threshold. This is also the trigger to start EPD\PPD mechanism, if set for the VPC.
C32 atmVpShaperEpdDropped1.3.6.1.4.1.164.12.2.1.2.1.7.1.5Counter32read-onlyThe number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last second. This parameter is limited to 24 bits. Applicable for a EPD/PPD VP only.
C32 atmVpShaperTotalEpdDropped1.3.6.1.4.1.164.12.2.1.2.1.7.1.6Counter32read-onlyThe Total number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last 15 minutes. This counter automatically reset itself every 15 minutes. Applicable for a EPD/PPD VP only.
atmVcPerformance1.3.6.1.4.1.164.12.2.1.2.2
atmVcCurrentTable1.3.6.1.4.1.164.12.2.1.2.2.1not-accessibleThe ATM VC Current table.
atmVcCurrentEntry1.3.6.1.4.1.164.12.2.1.2.2.1.1not-accessibleAn entry in the ATM VC Current table.
I32 atmVcCurrentVpi1.3.6.1.4.1.164.12.2.1.2.2.1.1.1Integer32read-onlyThe VPI of the VCL.
I32 atmVcCurrentVci1.3.6.1.4.1.164.12.2.1.2.2.1.1.2Integer32read-onlyThe VCI of the VCL.
G32 atmVcCurrentRxCellsClp011.3.6.1.4.1.164.12.2.1.2.2.1.1.3Gauge32read-onlyThe counter associated with the number of transmitted cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcCurrentRxCellsClp01.3.6.1.4.1.164.12.2.1.2.2.1.1.4Gauge32read-onlyThe counter associated with the number of received cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcCurrentGcra0Violations1.3.6.1.4.1.164.12.2.1.2.2.1.1.5Gauge32read-onlyThe counter associated with the number of cells violating GCRA0, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcCurrentGcra1Violations1.3.6.1.4.1.164.12.2.1.2.2.1.1.6Gauge32read-onlyThe counter associated with the number of cells violating GCRA1, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcCurrentRxAIS1.3.6.1.4.1.164.12.2.1.2.2.1.1.7Gauge32read-onlyThe counter associated with the number of received AIS cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcCurrentTxAIS1.3.6.1.4.1.164.12.2.1.2.2.1.1.8Gauge32read-onlyThe counter associated with the number of transmitted AIS cells, encountered by the VCL of this ATM interface in the current 15 minute interval. Not Supported in the first phase.
G32 atmVcCurrentRxRDI1.3.6.1.4.1.164.12.2.1.2.2.1.1.9Gauge32read-onlyThe counter associated with the number of received RDI cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcCurrentTxRDI1.3.6.1.4.1.164.12.2.1.2.2.1.1.10Gauge32read-onlyThe counter associated with the number of transmitted RDI cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcCurrentContinuityLoss1.3.6.1.4.1.164.12.2.1.2.2.1.1.11Gauge32read-onlyThe counter associated with the number of loss of continuity cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcCurrentUAS1.3.6.1.4.1.164.12.2.1.2.2.1.1.12Gauge32read-onlyThe counter associated with the number of Unavailable Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcCurrentSES1.3.6.1.4.1.164.12.2.1.2.2.1.1.13Gauge32read-onlyThe counter associated with the number of Severerly Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcCurrentCDC1.3.6.1.4.1.164.12.2.1.2.2.1.1.14Gauge32read-onlyAmount of cells dropped in the current 15 minute interval of the VC connection.
G32 atmVcCurrentTotalDiscards1.3.6.1.4.1.164.12.2.1.2.2.1.1.15Gauge32read-onlyThe total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
G32 atmVcCurrentClp0Discards1.3.6.1.4.1.164.12.2.1.2.2.1.1.16Gauge32read-onlyThe total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity.
G32 atmVcCurrentTotalCellOuts1.3.6.1.4.1.164.12.2.1.2.2.1.1.17Gauge32read-onlyThe total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
G32 atmVcCurrentClp0CellOuts1.3.6.1.4.1.164.12.2.1.2.2.1.1.18Gauge32read-onlyThe total number of valid ATM cells transmitted with CLP=0 by this VPL.
G32 atmVcCurrentTaggedOuts1.3.6.1.4.1.164.12.2.1.2.2.1.1.19Gauge32read-onlyThe total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
G32 atmVcCurrentPCR1.3.6.1.4.1.164.12.2.1.2.2.1.1.20Gauge32read-onlyThe maximum traffic rate encountered in the last interval of the VC connection (monitored once a second).
G32 atmVcCurrentSCR1.3.6.1.4.1.164.12.2.1.2.2.1.1.21Gauge32read-onlyThe average traffic rate during the last interval of the VC connection.
G32 atmVcCurrentMCR1.3.6.1.4.1.164.12.2.1.2.2.1.1.22Gauge32read-onlyMCR - The minimum traffic rate encountered in the last interval of the VC connection (monitored once a second).
G32 atmVcCurrentShaperTotalDiscards1.3.6.1.4.1.164.12.2.1.2.2.1.1.23Gauge32read-onlyThe total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
G32 atmVcCurrentShaperClp0Discards1.3.6.1.4.1.164.12.2.1.2.2.1.1.24Gauge32read-onlyThe total number of CLP0 cells discarded due to congestion by the traffic shaper.
G32 atmVcCurrentShaperClp1Discards1.3.6.1.4.1.164.12.2.1.2.2.1.1.25Gauge32read-onlyThe total number of CLP1 cells discarded due to congestion by the traffic shaper.
atmVcPMCurrentTable1.3.6.1.4.1.164.12.2.1.2.2.2not-accessibleThe ATM VC Current table for Performance Management.
atmVcPMCurrentEntry1.3.6.1.4.1.164.12.2.1.2.2.2.1not-accessibleAn entry in the ATM VC Current table for Performance Management.
I32 atmVcPMCurrentVpi1.3.6.1.4.1.164.12.2.1.2.2.2.1.1Integer32read-onlyThe VPI of the VCL.
I32 atmVcPMCurrentVci1.3.6.1.4.1.164.12.2.1.2.2.2.1.2Integer32read-onlyThe VCI of the VCL.
I32 atmVcPMCurrentDir1.3.6.1.4.1.164.12.2.1.2.2.2.1.3Integer32read-onlyThe direction of Performance Management.
G32 atmVcPMCurrentTxClp011.3.6.1.4.1.164.12.2.1.2.2.2.1.4Gauge32read-onlyThe counter associated with the number of transmitted CLP 0+1 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcPMCurrentTxClp01.3.6.1.4.1.164.12.2.1.2.2.2.1.5Gauge32read-onlyThe counter associated with the number of transmitted CLP 0 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcPMCurrentRxClp011.3.6.1.4.1.164.12.2.1.2.2.2.1.6Gauge32read-onlyThe counter associated with the number of received CLP 0+1 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcPMCurrentRxClp01.3.6.1.4.1.164.12.2.1.2.2.2.1.7Gauge32read-onlyThe counter associated with the number of received CLP 0 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcPMCurrentErroredCells1.3.6.1.4.1.164.12.2.1.2.2.2.1.8Gauge32read-onlyThe counter associated with the number of errored cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcPMCurrentLostCells1.3.6.1.4.1.164.12.2.1.2.2.2.1.9Gauge32read-onlyThe counter associated with the number of lost cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcPMCurrentMisinsertedCells1.3.6.1.4.1.164.12.2.1.2.2.2.1.10Gauge32read-onlyThe counter associated with the number of misinserted cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcPMCurrentECB1.3.6.1.4.1.164.12.2.1.2.2.2.1.11Gauge32read-onlyThe counter associated with the number of ECBs encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcPMCurrentSECB1.3.6.1.4.1.164.12.2.1.2.2.2.1.12Gauge32read-onlyThe counter associated with the number of SECBs encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcPMCurrentES1.3.6.1.4.1.164.12.2.1.2.2.2.1.13Gauge32read-onlyThe counter associated with the number of Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcPMCurrentSES1.3.6.1.4.1.164.12.2.1.2.2.2.1.14Gauge32read-onlyThe counter associated with the number of Severely Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
G32 atmVcPMCurrentUAS1.3.6.1.4.1.164.12.2.1.2.2.2.1.15Gauge32read-onlyThe counter associated with the number of Severely Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
INT atmVcPMCurrentIntervalQuality1.3.6.1.4.1.164.12.2.1.2.2.2.1.16INTEGERread-onlyIf the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
INT atmVcPMCurrentLastDayQuality1.3.6.1.4.1.164.12.2.1.2.2.2.1.17INTEGERread-onlyIf the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
atmVcIntervalTable1.3.6.1.4.1.164.12.2.1.2.2.3not-accessibleThe ATM Vc Interval table.
atmVcIntervalEntry1.3.6.1.4.1.164.12.2.1.2.2.3.1not-accessibleAn entry in the ATM Vc Interval table.
I32 atmVcIntervalVpi1.3.6.1.4.1.164.12.2.1.2.2.3.1.1Integer32read-onlyThe VPI of the VCL.
I32 atmVcIntervalVci1.3.6.1.4.1.164.12.2.1.2.2.3.1.2Integer32read-onlyThe VCI of the VCL.
I32 atmVcIntervalNumber1.3.6.1.4.1.164.12.2.1.2.2.3.1.3Integer32read-onlyA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
G32 atmVcIntervalRxCellsClp011.3.6.1.4.1.164.12.2.1.2.2.3.1.4Gauge32read-onlyThe counter associated with the number of transmitted cells , encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalRxCellsClp01.3.6.1.4.1.164.12.2.1.2.2.3.1.5Gauge32read-onlyThe counter associated with the number of received cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalGcra0Violations1.3.6.1.4.1.164.12.2.1.2.2.3.1.6Gauge32read-onlyThe counter associated with the number of cells violating GCRA0, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalGcra1Violations1.3.6.1.4.1.164.12.2.1.2.2.3.1.7Gauge32read-onlyThe counter associated with the number of cells violating GCRA1, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalRxAIS1.3.6.1.4.1.164.12.2.1.2.2.3.1.8Gauge32read-onlyThe counter associated with the number of received AIS cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalTxAIS1.3.6.1.4.1.164.12.2.1.2.2.3.1.9Gauge32read-onlyThe counter associated with the number of transmitted AIS cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals. Not supported in the first phase.
G32 atmVcIntervalRxRDI1.3.6.1.4.1.164.12.2.1.2.2.3.1.10Gauge32read-onlyThe counter associated with the number of received RDI cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalTxRDI1.3.6.1.4.1.164.12.2.1.2.2.3.1.11Gauge32read-onlyThe counter associated with the number of transmitted RDI cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalContinuityLoss1.3.6.1.4.1.164.12.2.1.2.2.3.1.12Gauge32read-onlyThe counter associated with the number of Continuity Loss cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalUAS1.3.6.1.4.1.164.12.2.1.2.2.3.1.13Gauge32read-onlyThe counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalSES1.3.6.1.4.1.164.12.2.1.2.2.3.1.14Gauge32read-onlyThe counter associated with the number of Severerly Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalCDC1.3.6.1.4.1.164.12.2.1.2.2.3.1.15Gauge32read-onlyAmount of cells dropped in the 15 minute interval of the VC connection.
G32 atmVcIntervalTotalDiscards1.3.6.1.4.1.164.12.2.1.2.2.3.1.16Gauge32read-onlyThe total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
G32 atmVcIntervalClp0Discards1.3.6.1.4.1.164.12.2.1.2.2.3.1.17Gauge32read-onlyThe total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity.
G32 atmVcIntervalTotalCellOuts1.3.6.1.4.1.164.12.2.1.2.2.3.1.18Gauge32read-onlyThe total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
G32 atmVcIntervalClp0CellOuts1.3.6.1.4.1.164.12.2.1.2.2.3.1.19Gauge32read-onlyThe total number of valid ATM cells transmitted with CLP=0 by this VPL.
G32 atmVcIntervalTaggedOuts1.3.6.1.4.1.164.12.2.1.2.2.3.1.20Gauge32read-onlyThe total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
G32 atmVcIntervalPCR1.3.6.1.4.1.164.12.2.1.2.2.3.1.21Gauge32read-onlyThe maximum traffic rate encountered in the last interval of the VC connection (monitored once a second) encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalSCR1.3.6.1.4.1.164.12.2.1.2.2.3.1.22Gauge32read-onlyThe average traffic rate during the last interval of the VC connection, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalMCR1.3.6.1.4.1.164.12.2.1.2.2.3.1.23Gauge32read-onlyMCR - The minimum traffic rate encountered in the last interval of the VC connection (monitored once a second) encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcIntervalShaperTotalDiscards1.3.6.1.4.1.164.12.2.1.2.2.3.1.24Gauge32read-onlyThe total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
G32 atmVcIntervalShaperClp0Discards1.3.6.1.4.1.164.12.2.1.2.2.3.1.25Gauge32read-onlyThe total number of CLP0 cells discarded due to congestion by the traffic shaper.
G32 atmVcIntervalShaperClp1Discards1.3.6.1.4.1.164.12.2.1.2.2.3.1.26Gauge32read-onlyThe total number of CLP1 cells discarded due to congestion by the traffic shaper.
atmVcPMIntervalTable1.3.6.1.4.1.164.12.2.1.2.2.4not-accessibleThe ATM Vc Interval table for Performance Management.
atmVcPMIntervalEntry1.3.6.1.4.1.164.12.2.1.2.2.4.1not-accessibleAn entry in the ATM Vc Interval table for Performance Management.
I32 atmVcPMIntervalVpi1.3.6.1.4.1.164.12.2.1.2.2.4.1.1Integer32read-onlyThe VPI of the VCL.
I32 atmVcPMIntervalVci1.3.6.1.4.1.164.12.2.1.2.2.4.1.2Integer32read-onlyThe VCI of the VCL.
INT atmVcPMIntervalDir1.3.6.1.4.1.164.12.2.1.2.2.4.1.3INTEGERread-onlyThe direction of Performance Management.
I32 atmVcPMIntervalNumber1.3.6.1.4.1.164.12.2.1.2.2.4.1.4Integer32read-onlyA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
G32 atmVcPMIntervalTxClp011.3.6.1.4.1.164.12.2.1.2.2.4.1.5Gauge32read-onlyThe counter associated with the number of transmitted CLP 0+1 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcPMIntervalTxClp01.3.6.1.4.1.164.12.2.1.2.2.4.1.6Gauge32read-onlyThe counter associated with the number of transmitted CLP 0 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcPMIntervalRxClp011.3.6.1.4.1.164.12.2.1.2.2.4.1.7Gauge32read-onlyThe counter associated with the number of received CLP 0+1 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcPMIntervalRxClp01.3.6.1.4.1.164.12.2.1.2.2.4.1.8Gauge32read-onlyThe counter associated with the number of received CLP 0 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcPMIntervalErroredCells1.3.6.1.4.1.164.12.2.1.2.2.4.1.9Gauge32read-onlyThe counter associated with the number of Errored cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcPMIntervalLostCells1.3.6.1.4.1.164.12.2.1.2.2.4.1.10Gauge32read-onlyThe counter associated with the number of Lost cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcPMIntervalMisinsertedCells1.3.6.1.4.1.164.12.2.1.2.2.4.1.11Gauge32read-onlyThe counter associated with the number of Misinserted cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcPMIntervalECB1.3.6.1.4.1.164.12.2.1.2.2.4.1.12Gauge32read-onlyThe counter associated with the number of ECBs encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcPMIntervalSECB1.3.6.1.4.1.164.12.2.1.2.2.4.1.13Gauge32read-onlyThe counter associated with the number of SECBs encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcPMIntervalES1.3.6.1.4.1.164.12.2.1.2.2.4.1.14Gauge32read-onlyThe counter associated with the number of Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcPMIntervalSES1.3.6.1.4.1.164.12.2.1.2.2.4.1.15Gauge32read-onlyThe counter associated with the number of Severely Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
G32 atmVcPMIntervalUAS1.3.6.1.4.1.164.12.2.1.2.2.4.1.16Gauge32read-onlyThe counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
INT atmVcPMIntervalQuality1.3.6.1.4.1.164.12.2.1.2.2.4.1.17INTEGERread-onlyIf the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
INT atmVcPMIntervalLastDayQuality1.3.6.1.4.1.164.12.2.1.2.2.4.1.18INTEGERread-onlyIf the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
atmVcQoSTable1.3.6.1.4.1.164.12.2.1.2.2.6not-accessibleThe ATM VP QoS table.
atmVcQoSEntry1.3.6.1.4.1.164.12.2.1.2.2.6.1not-accessibleAn entry in the ATM VP table.
INT atmVcQoSPeriodRef1.3.6.1.4.1.164.12.2.1.2.2.6.1.1INTEGERread-onlyThis object is an index that specifies which period of time, the next 2 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
I32 atmVcQoSElapsedTime1.3.6.1.4.1.164.12.2.1.2.2.6.1.2Integer32read-onlyElapsed Time in seconds. - for atmVcQoSPeriodRef = currentPeriod: The period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. - for atmVcQoSPeriodRef = lastPeriod: The value of atmVcQoSElapsedTime when last systemResetAllStatsCmd was received.
G32 atmVcQoSUAS1.3.6.1.4.1.164.12.2.1.2.2.6.1.3Gauge32read-onlyNumber of Unavailable Seconds for the reference period (atmVcQoSPeriodRef).
atmVcPMQoSTable1.3.6.1.4.1.164.12.2.1.2.2.7not-accessibleThe PM VC QoS table.
atmVcPMQoSEntry1.3.6.1.4.1.164.12.2.1.2.2.7.1not-accessibleAn entry in the VC PM QoS table.
INT atmVcPMQoSDirection1.3.6.1.4.1.164.12.2.1.2.2.7.1.1INTEGERread-onlyThe direction of performance management.
INT atmVcPMQoSPeriodRef1.3.6.1.4.1.164.12.2.1.2.2.7.1.2INTEGERread-onlyThis object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
G32 atmVcPMQoSCLR1.3.6.1.4.1.164.12.2.1.2.2.7.1.3Gauge32read-onlyCell Loss Ratio counter for the reference period (atmVcPMQoSPeriodRef)- defined in accordance with I.356 , in %. The value will be multipuled by 100.
G32 atmVcPMQoSCER1.3.6.1.4.1.164.12.2.1.2.2.7.1.4Gauge32read-onlyCell Error Ratio counter for the reference period (atmVcPMQoSPeriodRef) defined in accordance with I.356 , in %. The value will be multipuled by 100.
G32 atmVcPMQoSCMR1.3.6.1.4.1.164.12.2.1.2.2.7.1.5Gauge32read-onlyCell Miss-insertion Ratio counter for the reference period (atmVcPMQoSPeriodRef) defined in accordance with I.356 , cells/sec .
atmVcShaperStatTable1.3.6.1.4.1.164.12.2.1.2.2.8not-accessibleThe ATM VC shaper statistics table.
atmVcShaperStatEntry1.3.6.1.4.1.164.12.2.1.2.2.8.1not-accessibleAn entry in the ATM VC shaper statistics table.
C32 atmVcShaperDiscarded1.3.6.1.4.1.164.12.2.1.2.2.8.1.1Counter32read-onlyThe number of Cells that were discarded in the shaper on that VCC due to buffer overflow. This counter counts till it reaches its MAX value (20 bits) and then rolls over.
I32 atmVcShaperOccupation1.3.6.1.4.1.164.12.2.1.2.2.8.1.2Integer32read-onlyThe number of Cells that are currently stored in the buffer. This parameter is limited to 20 bits.
I32 atmVcShaperMaxOccupation1.3.6.1.4.1.164.12.2.1.2.2.8.1.3Integer32read-onlyThe Maximum number of Cells that were stored in the buffer, since this VC was activated. This parameter is limited to 20 bits.
INT atmVcShaperLevel1.3.6.1.4.1.164.12.2.1.2.2.8.1.4INTEGERread-onlyThe occupation of the buffer according to a predefined threshold. empty - buffer is Empty full - buffer is Full below - buffer is Below the threshold above - buffer is Above the threshold. This is also the trigger to start EPD\PPD mechanism, if set for the VCC.
C32 atmVcShaperEpdDropped1.3.6.1.4.1.164.12.2.1.2.2.8.1.5Counter32read-onlyThe number of Cells that were dropped in the shaper on that VCC due to EPD\PPD mechanism in the last second. This parameter is limited to 24 bits. Applicable for a EPD/PPD VC only.
C32 atmVcShaperTotalEpdDropped1.3.6.1.4.1.164.12.2.1.2.2.8.1.6Counter32read-onlyThe Total number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last 15 minutes. This counter automatically reset itself every 15 minutes. Applicable for a EPD/PPD VC only.
atmIntervalDateTable1.3.6.1.4.1.164.12.2.1.3not-accessibleThe agent will keep in this group the date & time corresponding to each interval.
atmIntervalDateEntry1.3.6.1.4.1.164.12.2.1.3.1not-accessibleThe date & time for the given interval.
I32 atmIntervalDateInterval1.3.6.1.4.1.164.12.2.1.3.1.1Integer32read-onlyThe interval number defining this entry.
STR atmIntervalDateDate1.3.6.1.4.1.164.12.2.1.3.1.2DisplayStringread-onlyThe date corresponding to this interval.
STR atmIntervalDateTime1.3.6.1.4.1.164.12.2.1.3.1.3DisplayStringread-onlyThe time corresponding to this interval.
atmGenSystem1.3.6.1.4.1.164.12.2.2
atmGenSysGen1.3.6.1.4.1.164.12.2.2.1
atmGenSysSelfTestTable1.3.6.1.4.1.164.12.2.2.1.1not-accessibleA table containing the results of the initial testing of the device.
atmGenSysSelfTestEntry1.3.6.1.4.1.164.12.2.2.1.1.1not-accessibleAn entry in table.
I32 atmGenSysSelfTestIndex1.3.6.1.4.1.164.12.2.2.1.1.1.1Integer32read-onlyA running index for the table.
STR atmGenSysSelfTestResult1.3.6.1.4.1.164.12.2.2.1.1.1.2DisplayStringread-onlyThe results of the initial testing of the device.
STR atmGenSysSelfTestModule1.3.6.1.4.1.164.12.2.2.1.1.1.3DisplayStringread-onlyThe name of module on which the test was performed.
INT atmGenSysLogClearAll1.3.6.1.4.1.164.12.2.2.1.2INTEGERread-writeSetting the variable to clear(3) removes all entries in the Log Buffer of the agent. The agent will immediately reset the variable to off(2).
atmGenSysLogTable1.3.6.1.4.1.164.12.2.2.1.3not-accessibleA copy of the log buffer.
atmGenSysLogEntry1.3.6.1.4.1.164.12.2.2.1.3.1not-accessibleAn entry in table.
I32 atmGenSysLogIndex1.3.6.1.4.1.164.12.2.2.1.3.1.1Integer32read-onlyThe index of the log buffer.
STR atmGenSysLogMessage1.3.6.1.4.1.164.12.2.2.1.3.1.2DisplayStringread-onlyThe log buffer entry message text.
INT atmGenSysSetDefaultConfg1.3.6.1.4.1.164.12.2.2.1.4INTEGERread-writeWhen set to on(3), the agent will set all the configuration parameters to their default values. The variable is then reset to off(2) by the agent. The agent must be reset for the default configuration to apply.
atmGenSysCxRefTable1.3.6.1.4.1.164.12.2.2.1.5not-accessibleA Cross Reference table. The table maintains an index of an object which is also the table index, and a counter that indicates how many times this object was referenced. When using this table for more than one referenced table, which uses the same range of indexes, then the index should be shifted by a unique offset per table. In ACE2002 this table is used for TD and for FR Desc. Thus, the index for FR Descriptor is: FR Descriptor index + offset. The offset is described in the ACE2002 NMS SRS.
atmGenSysCxRefEntry1.3.6.1.4.1.164.12.2.2.1.5.1not-accessibleThe entries will be added by the agent upon an entry addition in the referenced tables (TD table, FR Descriptor etc.)
I32 atmGenSysCxRefIndex1.3.6.1.4.1.164.12.2.2.1.5.1.1Integer32read-onlyThe index specifies an entry in the table of the object.
G32 atmGenSysCxRefCounter1.3.6.1.4.1.164.12.2.2.1.5.1.2Gauge32read-onlyThe counter counts the number of references that have been made to the object .
atmNte1.3.6.1.4.1.164.12.3
atmNteEvents1.3.6.1.4.1.164.12.3.0The events for RAD ATM products.
NTF atmAceStatusChange1.3.6.1.4.1.164.12.3.0.1The trap is sent every time there is a change in the state of one of the LEDs.
NTF atmAceAlarmTrap1.3.6.1.4.1.164.12.3.0.2The trap is sent whenever there is a transition from a no alarm state to a state with at least one active alarm. An active alarm state exists if: 1) The atmInterfaceActiveAlarms vector is different than 0. 2) The atmNteAlarmVpTable contains entries. 3) The atmNteAlarmVcTable contains entries. The trap is also sent when a transition into the no alarm state occurs. The second variable will be atmInterfaceActiveAlarms to indicate the kind of the alarm. The trap is not sent more than once in a 10 second interval.
NTF atmAceModuleChangeTrap1.3.6.1.4.1.164.12.3.0.3The trap is sent every time a module is changed (Hot swapping). The second variable will be atmNteCardType to indicate the type of card that was inserted. The value empty(255) indicates that a card was taken out.
NTF atmAceRedundancyTrap1.3.6.1.4.1.164.12.3.0.4The trap is sent upon change in link as a result of redundancy. The ifIndex parameter indicates the current active link.
NTF atmAceModuleMismatchTrap1.3.6.1.4.1.164.12.3.0.5The trap is sent upon starting or stopping of a module mismatch state. A possible mismatch is when the inserted module is other than the programmed one.
atmNteSys1.3.6.1.4.1.164.12.3.1
atmNteSysConfig1.3.6.1.4.1.164.12.3.1.1
atmNteManagerTable1.3.6.1.4.1.164.12.3.1.1.1not-accessibleThe Manager Table includes all the NMSs that receive traps from this agent. A single manager can receive traps on more than one PVC. The agent will set implicitly the correct ifIndex, VPI, VCI values to all relevant entries in the table when the user changes them for one of the PVCs.
atmNteManagerEntry1.3.6.1.4.1.164.12.3.1.1.1.1not-accessibleA single manager and the PVC for receiving traps.
IP atmNteManagerIP1.3.6.1.4.1.164.12.3.1.1.1.1.1IpAddressread-onlyThe IP address of the NMS.
I32 atmNteManagerPvc1.3.6.1.4.1.164.12.3.1.1.1.1.2Integer32read-onlyA PVC index. The range is 1..8. There are four PVCs on the User Port and four PVCs on the Network Port. The default VPI, VCI values are specified below.
I32 atmNteManagerIfIndex1.3.6.1.4.1.164.12.3.1.1.1.1.3Integer32read-createThe ATM interface index of the management port.
I32 atmNteManagerVpi1.3.6.1.4.1.164.12.3.1.1.1.1.4Integer32read-createThe VPI of the management VCL. Default: 0.
I32 atmNteManagerVci1.3.6.1.4.1.164.12.3.1.1.1.1.5Integer32read-createThe VCI of the management VCL. Defaults: 32,33,34,35.
I32 atmNteManagerTrapMask1.3.6.1.4.1.164.12.3.1.1.1.1.6Integer32read-createThe value of this attribute determines the type of traps the agent should mask and not send to this NMS. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed.
ROW atmNteManagerRowStatus1.3.6.1.4.1.164.12.3.1.1.1.1.7RowStatusread-createCreation/Deletion of rows in the table.
IP atmNteManagerNextHop1.3.6.1.4.1.164.12.3.1.1.1.1.8IpAddressread-createThis parameter is relevant to Ethernet out of band host only (PVC=10). The Next Hop IP address of the entry route.
INT atmNteManagerVlanSupport1.3.6.1.4.1.164.12.3.1.1.1.1.9INTEGERread-createVLAN support (Tagging). no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame.
I32 atmNteManagerVlanIdentifier1.3.6.1.4.1.164.12.3.1.1.1.1.10Integer32read-createVLAN ID. Range is 0..4095.
I32 atmNteManagerVlanFramePriority1.3.6.1.4.1.164.12.3.1.1.1.1.11Integer32read-createVLAN Frame priority.Range is 0..7.
OCT atmNteManagerAlarmTrapMask1.3.6.1.4.1.164.12.3.1.1.1.1.12OCTET STRINGread-createThe value of this object determines the alarm traps that the agent should mask and not send to this NMS. The value is an Octet String, where each bit is assigned to a certain trap. If the bit = 1, the trap will be masked. If the bit = 0, the trap will not be masked. More details on the masked traps exist in the product specification. For products that do not mask specific traps, the value of the bits will be 0.
I32 atmNteManagerConfigPorts1.3.6.1.4.1.164.12.3.1.1.1.1.13Integer32read-createThis variable defines from which port/s this manager can configure the device. For IPmux 11 the value of this variable will be according to the ports combination: Network =1 User1=2 User2=4 (For Example: All ports = 7).
I32 atmNteUPLTCR1.3.6.1.4.1.164.12.3.1.1.2Integer32read-writeThe Unacceptable ES Limit threshold for Performance Management.
I32 atmNteDPLTCR1.3.6.1.4.1.164.12.3.1.1.3Integer32read-writeThe Degraded ES Limit threshold for Performance Management.
INT atmNteSysLogClearAll1.3.6.1.4.1.164.12.3.1.1.4INTEGERread-writeSetting the variable to clear(3) removes all entries in the Log Buffer of the agent. The agent will immediately reset the variable to off(2).
I32 atmNteUSESLTCR1.3.6.1.4.1.164.12.3.1.1.5Integer32read-writeThe Unacceptable SES Limit threshold for Performance Management.
I32 atmNteDSESLTCR1.3.6.1.4.1.164.12.3.1.1.6Integer32read-writeThe Degraded ES Limit threshold for Performance Management.
atmNteProtection1.3.6.1.4.1.164.12.3.1.1.8
INT atmNteProtectionMode1.3.6.1.4.1.164.12.3.1.1.8.1INTEGERread-writeProtection Mode. MspOn - Multiplex section protection. pathOn - High order path protection. mspUniOn - Multiplex section Uni-directional protection. mspOneToN - Multiplex section protection.
INT atmNteProtectionWorkingLink1.3.6.1.4.1.164.12.3.1.1.8.2INTEGERread-writeSelects the working link when atmNteProtectionMode is off.
INT atmNteProtectionSwitchLink1.3.6.1.4.1.164.12.3.1.1.8.3INTEGERread-writeForceSwitch - will force Switching from the working link to the backup link. Afterwards the agent will set atmNteProtectionSwitchLink back to off(1). atmNteProtectionMode must be either mspOn or pathOn.
atmNteConfOam1.3.6.1.4.1.164.12.3.1.1.9
INT atmNteConfOamSupport1.3.6.1.4.1.164.12.3.1.1.9.1INTEGERread-writeOAM support mode, which determines the device location in a segment wise.
atmNteConfOamTransmission1.3.6.1.4.1.164.12.3.1.1.9.2
INT atmNteConfOamAIS1.3.6.1.4.1.164.12.3.1.1.9.2.1INTEGERread-writeDefines if a F4 segment OAM cell is transmitted due to problems in the other port, i.e. physical layer alarm or F4 defect. This is valid only when the ACE101 has ATM UNI interfaces in both sides and is configured for 'Non-Intrusive' mode. none - AIS is not sent to any of the ports. user - F4 AIS will be sent toward the user when defect is detected in the network port. network - F4 AIS will be sent toward the network when defect is detected in the user port. both - F4 AIS will be sent toward the network when defect is detected in the user port and toward the user when defect is detected in the network port.
INT atmNteConfOamRDI1.3.6.1.4.1.164.12.3.1.1.9.2.2INTEGERread-writeDefines if an F4 OAM RDI cell is transmitted due to physical layer problems in the port (in addition to F4 RDI cells transmitted due to ATM layer problems). The type of F4 RDI (Segment or End-to-End) is according to the ACE-101 OAM mode. For example, If it is enabled for Network port, then physical layer defect will initiate the transmission of F4 RDI cell back to the trunk.
atmNteConfOamAddressing1.3.6.1.4.1.164.12.3.1.1.9.3
INT atmNteConfLoopbackAddMode1.3.6.1.4.1.164.12.3.1.1.9.3.1INTEGERread-writeLoopback addressing mode. on - will enable loopback addressing. off - will disable loopback addressing.
OCT atmNteConfLoopbackSourceAdd1.3.6.1.4.1.164.12.3.1.1.9.3.2OCTET STRINGread-writeLoopback source address. This field is relevant when atmNteConfOamAddMode is on.
atmNteConfOamIfTable1.3.6.1.4.1.164.12.3.1.1.9.4not-accessibleOAM support per ATM interface.
atmNteConfOamIfEntry1.3.6.1.4.1.164.12.3.1.1.9.4.1not-accessible.
INT atmNteConfOamIfAisRdi1.3.6.1.4.1.164.12.3.1.1.9.4.1.1INTEGERread-writeThis parameter controls the generation of F4/F5 AIS and RDI due to lower order problems such as physical layer problems. For AIS: Defines if F4/F5 AIS cell is transmitted due to problems such as physical layer alarm or F4/F5 defect. This is applicable for all ports . off - Problems in this port will not trigger F4/F5 AIS transmition to the ajacent port (e.g. from USER to NETWORK) of a VPC/VCC. on - Problems in this port will trigger F4/F5 AIS transmition to the ajacent port (e.g. from USER to NETWORK) of a VPC/VCC. For RDI: Defines if F4/F5 RDI cell will be transmitted due to physical layer problems in that port (in addition to F4/F5 RDI cells transmitted due to ATM layer problems). For example, If it is enabled for Network port, then physical layer defect will initiate the transmission of F4/F5 RDI cell back to the trunk. The type of F4/F5 (Segment or End-to-End) is according to the configuration of the VPC/VCC.
atmNteConfCAC1.3.6.1.4.1.164.12.3.1.1.10
INT atmNteConfCACMode1.3.6.1.4.1.164.12.3.1.1.10.1INTEGERread-writeCAC support mode. For ACE2002, the following are the applicable values: disable(1), enable(2), 10 - 1000.
atmNteHostIfTable1.3.6.1.4.1.164.12.3.1.1.11not-accessibleHost IP interface table.
atmNteHostIfEntry1.3.6.1.4.1.164.12.3.1.1.11.1not-accessible.
I32 atmNteHostPvcIndex1.3.6.1.4.1.164.12.3.1.1.11.1.1Integer32read-onlyA PVC index. The range is 1..10.
IP atmNteHostIP1.3.6.1.4.1.164.12.3.1.1.11.1.2IpAddressread-createThe host interface IP address.
IP atmNteHostMask1.3.6.1.4.1.164.12.3.1.1.11.1.3IpAddressread-createThe host interface subnet mask.
I32 atmNteHostAtmIfIndex1.3.6.1.4.1.164.12.3.1.1.11.1.4Integer32read-createATM interface index. Will be 1 for user port, and 2 for network port.
I32 atmNteHostVpi1.3.6.1.4.1.164.12.3.1.1.11.1.5Integer32read-createVPI of the PVC connected to that host interface.
I32 atmNteHostVci1.3.6.1.4.1.164.12.3.1.1.11.1.6Integer32read-createVCI of the PVC connected to that host interface.
ROW atmNteHostRowStatus1.3.6.1.4.1.164.12.3.1.1.11.1.7RowStatusread-createCreation/Deletion of rows in the table.
I32 atmNteHostRdnVpi1.3.6.1.4.1.164.12.3.1.1.11.1.8Integer32read-createThe VPI of the redundant management VCL. This parameter is applicable only if atmNteRdnManagement=enable(3).
I32 atmNteHostRdnVci1.3.6.1.4.1.164.12.3.1.1.11.1.9Integer32read-createThe VCI of the redundant management VCL. This parameter is applicable only if atmNteRdnManagement=enable(3).
IP atmNteHostDefaultNextHop1.3.6.1.4.1.164.12.3.1.1.11.1.10IpAddressread-createThe host interface Default Next Hop address. This address will be used as default next hop for every Bundle mapped to this Host.
INT atmNteHostVlanTagging1.3.6.1.4.1.164.12.3.1.1.11.1.11INTEGERread-createVLAN Tag support. no - No support to VLAN. yes - 4 VLAN bytes will be added to each frame connected to this Host.
I32 atmNteHostDefaultVlanID1.3.6.1.4.1.164.12.3.1.1.11.1.12Integer32read-createDefault VLAN ID of this Host.
I32 atmNteHostDefaultVlanPriority1.3.6.1.4.1.164.12.3.1.1.11.1.13Integer32read-createDefault VLAN priority for this Host.
INT atmNteShaperMode1.3.6.1.4.1.164.12.3.1.1.12INTEGERread-writeShaper Mode. vpInbandMng - Vcc within a Vp for management.
I32 atmNteOutputRate1.3.6.1.4.1.164.12.3.1.1.13Integer32read-writeAggregate shaping output rate in Cells per Seconds units. Default value is the Network port rate.
INT atmNteTosMode1.3.6.1.4.1.164.12.3.1.1.14INTEGERread-writeTOS Mode.
OCT atmNteTosMask1.3.6.1.4.1.164.12.3.1.1.15OCTET STRINGread-writeThis parameter determines the seqence of bits that will be used for TOS. For ACE101 this parameter is applicable only if atmNteTosMode = enable. Valid only for IP-TOS process.
OCT atmNteTosHighPriority1.3.6.1.4.1.164.12.3.1.1.16OCTET STRINGread-writePriorities options are High or Low. High priority will be represented by bit = 1. Low priority will be represented by bit = 0. Each TOS value will be represented by the bit location. For example, the string for TOS 2, 9, 15 with High priority, will be: |0000 0000|... ...|0000 0000|1000 0010|0000 0100| ...98 7654 3210 (Bit #) 8 ... 3 2 1 (Byte #).
INT atmNtePlugAndPlayActivity1.3.6.1.4.1.164.12.3.1.1.17INTEGERread-writeActivity control for Manager Plug And Play. disable - disable the feature. offline - Automatic learn IP address into offline memory. online - Automatic learn IP address into online memory.
INT atmNteSlotUsage1.3.6.1.4.1.164.12.3.1.1.18INTEGERread-writeApplicable to ace2002. Slot 2 might be configured as user slot or as network slot.
INT atmNteConnectionsMaxNumber1.3.6.1.4.1.164.12.3.1.1.19INTEGERread-writeThe MAX number of connections supported by system. Setting this parameter will affect the number of MAX intervals supported. This parameter will affect the system only after reset. Changing this parameter from high value to a low value, will be accepted by agent only if the actual used connection <= the desired connection Max number. Applicable to ace2002.
I32 atmNteDefaultVpi1.3.6.1.4.1.164.12.3.1.1.20Integer32read-writeDefault Vpi for management.
I32 atmNteDefaultVci1.3.6.1.4.1.164.12.3.1.1.21Integer32read-writeDefault Vci for management.
I32 atmNteReservedVpi1.3.6.1.4.1.164.12.3.1.1.22Integer32read-writeInternal use VPI, where shaperMode=vpInbandMng.
INT atmNteRdnManagement1.3.6.1.4.1.164.12.3.1.1.23INTEGERread-onlyThe redundancy management status.
NUM atmNtePlugAndPlayIfIndex1.3.6.1.4.1.164.12.3.1.1.24InterfaceIndexread-writeThe ifIndex of the Plug and Play VCC.
I32 atmNteLoopbackTimeout1.3.6.1.4.1.164.12.3.1.1.25Integer32read-writeThe Loopback state timeout in minutes. A value of zero means no timeout (for ever). Default is 5 min.
atmNteOamTable1.3.6.1.4.1.164.12.3.1.1.26not-accessibleThis table is a static table, which is created by agent once upon initialization. The created entries are actually, only the supported OAM features. This table enables addition of new features by adding new entries rather than adding scalar parameters. An OAM feature is defined by the indexes values combination.
atmNteOamEntry1.3.6.1.4.1.164.12.3.1.1.26.1not-accessibleAn entry in the OAM table. Each entry in this table will indicate a special OAM.
INT atmNteOamMode1.3.6.1.4.1.164.12.3.1.1.26.1.1INTEGERread-onlyThe OAM cell path. endToEnd(1) - the entire path.
INT atmNteOamCellType1.3.6.1.4.1.164.12.3.1.1.26.1.2INTEGERread-onlyThis object indicates a unique Indication Signal. aisAndRdi(1) - Alarm Indication Signal (AIS) and Remote Defect Indication (RDI) cell. loopback(2) - Loopback cell.
INT atmNteOamLevel1.3.6.1.4.1.164.12.3.1.1.26.1.3INTEGERread-onlyThe level of the OAM cell. -- f4 (2) - VP level, f5 (3) - VC level.
INT atmNteOamEnable1.3.6.1.4.1.164.12.3.1.1.26.1.4INTEGERread-writeThis parameter determines if the specified OAM cells will be enabled.
I32 atmNteDefaultLoopbackThreshold1.3.6.1.4.1.164.12.3.1.1.27Integer32read-writeThe Default OAM Loopback Failure Threshold value that will be used for configuration.
I32 atmNteMaxBurstSize1.3.6.1.4.1.164.12.3.1.1.28Integer32read-writeThe Maximum allowed burst size (cell units). This object is applicable for each Physical port.
I32 atmNteGranularityFactor1.3.6.1.4.1.164.12.3.1.1.29Integer32read-writeThis parameter affects the granularity of the guaranteed Rate (SCR+MCR) in spaced connection (cell/sec units). It is also defines the minimum guaranteed rate in spaced connection.
I32 atmNteTotalInputRate1.3.6.1.4.1.164.12.3.1.1.30Integer32read-onlyThis parameter indicates the total input rate of the device in cells/sec.
I32 atmNteTotalOutputRate1.3.6.1.4.1.164.12.3.1.1.31Integer32read-onlyThis parameter indicates the total output rate of the device in cells/sec.
atmAlarmForwardingTable1.3.6.1.4.1.164.12.3.1.1.32not-accessibleThe Alarm Forwarding Mechanism will be operated for this table entries.
atmAlarmForwardingEntry1.3.6.1.4.1.164.12.3.1.1.32.1not-accessibleEach entry in this table is a pair of ports that the Alarm Forwarding Mechanism is determined for.
I32 atmAlarmForwardingFailPort1.3.6.1.4.1.164.12.3.1.1.32.1.1Integer32not-accessibleAn Index of the port on which a fail occurs.
I32 atmAlarmForwardingToPort1.3.6.1.4.1.164.12.3.1.1.32.1.2Integer32not-accessibleAn Index of the port that will be affected upon the failure of the atmAlarmForwardingFailPort.
ROW atmAlarmForwardingRowStatus1.3.6.1.4.1.164.12.3.1.1.32.1.3RowStatusread-createCreation/Deletion of rows in the table.
BIT atmAlarmForwardingFailureLevel1.3.6.1.4.1.164.12.3.1.1.32.1.4Bitsread-createThis parameter determines the level of failure that will operate the Alarm Forwarding Mechanism.
INT atmAlarmForwardingRecoveryMode1.3.6.1.4.1.164.12.3.1.1.32.1.5INTEGERread-createThis parameter determines the Recovery Mode. manual - The user should stop the RDI transmission by using the atmAlarmForwardingRecoveryCommand. automatic - The RDI transmission will be automatically stopped upon atmAlarmForwardingFailPort recovery.
INT atmAlarmForwardingRecoveryCommand1.3.6.1.4.1.164.12.3.1.1.32.1.6INTEGERread-createThis parameter is a command. It is applicable when atmAlarmForwardingRecoveryMode = manual. on - Will stop the RDI transmission. After setting to 'On' the agent will set this parameter back to 'Off'.
U32 atmAlarmForwardingTimeFilterWindow1.3.6.1.4.1.164.12.3.1.1.32.1.7Unsigned32read-createThis parameter determines the Time Filter Window, meaning: how much time (in seconds) should the alarm exist in order to start the Alarm Forwarding operation.
atmSysConfigCellTest1.3.6.1.4.1.164.12.3.1.1.33
NUM atmSysConfigCellTestPort1.3.6.1.4.1.164.12.3.1.1.33.1InterfaceIndexread-writeAn Index of the port on which the cell test will be sent.
I32 atmSysConfigCellTestVpi1.3.6.1.4.1.164.12.3.1.1.33.2Integer32read-writeThe VPI on which the cell test will be sent.
I32 atmSysConfigCellTestVci1.3.6.1.4.1.164.12.3.1.1.33.3Integer32read-writeThe VCI on which the cell test will be sent.
INT atmSysConfigCellTestPti1.3.6.1.4.1.164.12.3.1.1.33.4INTEGERread-writeThe cell type.
INT atmSysConfigCellTestClp1.3.6.1.4.1.164.12.3.1.1.33.5INTEGERread-writeThe type of the Cell.
INT atmSysConfigCellTestOamType1.3.6.1.4.1.164.12.3.1.1.33.6INTEGERread-writeThe OAM type of the Cell. This object is applicable if atmSysConfigCellTestPti = oamSegment/oamEndToEnd .
OCT atmSysConfigCellTestPayload1.3.6.1.4.1.164.12.3.1.1.33.7OCTET STRINGread-writeThe payload of the cell. For OAM cell the payload is set automatically to 6A.
I32 atmSysConfigCellTestQuantity1.3.6.1.4.1.164.12.3.1.1.33.8Integer32read-writeQuantity of cells to send.
INT atmSysConfigCellTestSendCmd1.3.6.1.4.1.164.12.3.1.1.33.9INTEGERread-writeSetting the variable to send(3) perfroms cell test. The agent will immediately reset the variable to off(2).
atmVpCrossConnectExtenTable1.3.6.1.4.1.164.12.3.1.1.34not-accessibleAn extension to the ATM VP Cross Connect table (RFC2515 - atmVpCrossConnectTable).
atmVpCrossConnectExtenEntry1.3.6.1.4.1.164.12.3.1.1.34.1not-accessibleAn entry in the table.
STR atmVpCrossConnectName1.3.6.1.4.1.164.12.3.1.1.34.1.1SnmpAdminStringread-createThe Connection's name.
atmVcCrossConnectExtenTable1.3.6.1.4.1.164.12.3.1.1.35not-accessibleAn extension to the ATM VC Cross Connect table (RFC2515 - atmVcCrossConnectTable).
atmVcCrossConnectExtenEntry1.3.6.1.4.1.164.12.3.1.1.35.1not-accessibleAn entry in the table.
STR atmVcCrossConnectName1.3.6.1.4.1.164.12.3.1.1.35.1.1SnmpAdminStringread-createThe Connection's name.
INT atmNteQosMode1.3.6.1.4.1.164.12.3.1.1.37INTEGERread-writeThis variable defines the QoS Mode. disable(1) - QoS is disabled. multipleVc(2) - QoS is enabled and multiple VCs can be bound per bridge port. singleVc(3) - QoS is enabled and only single VC can be bound per bridge port.
atmTrafficDescrParamXTable1.3.6.1.4.1.164.12.3.1.1.38not-accessibleAn Augment to ATM Traffic Descriptor Parameter Table (atmTrafficDescrParamTable in ATM-MIB; RFC-2515).
atmTrafficDescrParamXEntry1.3.6.1.4.1.164.12.3.1.1.38.1not-accessibleAn entry in the table.
INT atmTrafficDescrParamMode1.3.6.1.4.1.164.12.3.1.1.38.1.1INTEGERread-createThe Mode of the Traffic Descriptor.
atmNteSysInfo1.3.6.1.4.1.164.12.3.1.2
atmNteIdTable1.3.6.1.4.1.164.12.3.1.2.1not-accessibleThe IDs of the cards and of the system.
atmNteIdEntry1.3.6.1.4.1.164.12.3.1.2.1.1not-accessible.
I32 atmNteIdIndex1.3.6.1.4.1.164.12.3.1.2.1.1.1Integer32read-onlyAn Index of the Unit ID table. The following units have IDs in this table: 1 - System 2 - ATM Board 3 - User Card 4 - Trunk 1 card 5 - Trunk 2 card 6 - Shaper 7 - Clock Unit 8 - Slot 1 card 9 - Slot 2 card 10 - Slot 3 card 11 - Slot 4 card 12 - Fan1 13 - Fan2 14 - Control Unit.
I32 atmNteUnitId1.3.6.1.4.1.164.12.3.1.2.1.1.2Integer32read-onlyThe ID of the Unit. For index = 6, the id will describe the validity of a shaper in the system: 0 - Shaper Not exist 1 - Shaper exist. For index = 7, the id will describe the validity of a clock in the system: 0 - Clock Not exist 1 - Clock exist. 2- Clock exist but failed. For index = 12,13 the id will describe the functionality of a FAN1 : 0 - OK 1 - Failed.
STR atmNteUnitVersion1.3.6.1.4.1.164.12.3.1.2.1.1.3DisplayStringread-onlyHardware and Software version of the module.
INT atmNteCardType1.3.6.1.4.1.164.12.3.1.2.1.1.4INTEGERread-onlyThe card type.
INT atmNteCardStatus1.3.6.1.4.1.164.12.3.1.2.1.1.5INTEGERread-onlyStatus of the card in the selected slot. notActive - Connections are in NotReady state. No configuration is available for the card. The access to the card HW is blocked. This state is relevant for an extracted card, and for a case in which the card was deactivated. active - The module installed and functions. A card that in this state can be configured. inProgress - The status during proccessing of a command from atmNteCardCmd. empty - No information is valid for the selected slot. This status is relevant to a case in which the card configaration was deleted, or in case in which a slot was empty since the device startup.
INT atmNteCardCmd1.3.6.1.4.1.164.12.3.1.2.1.1.6INTEGERread-writeCommand on the card that is installed in the selected slot. The commands are applicable according to the value of atmNteCardStatus. See the specification document for details. deleteConfig - Deletes the card configuration. deactivate - All the connections state will be changed to NotReady. The card configuration will be blocked. activate - Does the same as done upon card insertion: Initiates the relevant parameters, activates the physical layer, ATM layer and logical layer.
INT atmNteProgCardType1.3.6.1.4.1.164.12.3.1.2.1.1.7INTEGERread-writeThe programmed card type.
I32 atmSysPSunits1.3.6.1.4.1.164.12.3.1.2.2Integer32read-onlyThe number of power supply units.
INT atmSysPSunitsInUse1.3.6.1.4.1.164.12.3.1.2.3INTEGERread-onlyThe main power supply in this unit.
I32 atmSysFanUnits1.3.6.1.4.1.164.12.3.1.2.4Integer32read-onlyThe number of fan units.
I32 atmSysNetPrts1.3.6.1.4.1.164.12.3.1.2.5Integer32read-onlyThe number of network ports.
INT atmSysNetPrtInUse1.3.6.1.4.1.164.12.3.1.2.6INTEGERread-onlyThe network port in use.
INT atmNteBridgingMode1.3.6.1.4.1.164.12.3.1.2.7INTEGERread-writeBridging mode can be one of the following: ATM <> Ethernet - Bridging is between the Ethernet port and the ATM port (there is no bridging between VCs). ATM <> Ethernet + ATM - Bridging is done both between the Ethernet port and the ATM port and also between VCs.
atmSysStats1.3.6.1.4.1.164.12.3.1.2.8
G32 atmSysCurrentCdc1.3.6.1.4.1.164.12.3.1.2.8.1Gauge32read-onlySeconds in which cells dropped was occured in the current 15 minutes interval.
atmSysIntervalTable1.3.6.1.4.1.164.12.3.1.2.8.2not-accessibleThe system level Interval table.
atmSysIntervalEntry1.3.6.1.4.1.164.12.3.1.2.8.2.1not-accessible.
I32 atmSysIntervalNumber1.3.6.1.4.1.164.12.3.1.2.8.2.1.1Integer32read-onlyA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
G32 atmSysIntervalCdc1.3.6.1.4.1.164.12.3.1.2.8.2.1.2Gauge32read-onlySeconds in which cells dropped was occured in 15 minutes interval.
INT atmNteEventType1.3.6.1.4.1.164.12.3.1.2.9INTEGERread-onlyThis parameter identifies the event. On - the problem exist. Off - the problem not exist. InvalidLogin - Invalid login on local console. CorrectLogin - Successful login operation.
I32 atmNteIntervalMaxNumber1.3.6.1.4.1.164.12.3.1.2.10Integer32read-onlyThe MAX number of connections intervals supported by system. This parameter value is a function of atmNteConnectionsMaxNumber parameter. This parameter should affect the threshold values selected by user. Applicable to ace2002.
INT atmNteAlarmType1.3.6.1.4.1.164.12.3.1.2.11INTEGERread-onlyThis object specifies the type of the alarm.
INT atmNteLevel1.3.6.1.4.1.164.12.3.1.2.12INTEGERread-onlyThis object specifies the ATM level.
I32 atmNteConnectionsNumber1.3.6.1.4.1.164.12.3.1.2.13Integer32read-onlyThis object specifies a quantity of connections.
I32 atmNteTotalLb1.3.6.1.4.1.164.12.3.1.2.14Integer32read-onlyThis parameter counts the total number of end-points that were configured with Loopback (LB).
I32 atmNteTotalCc1.3.6.1.4.1.164.12.3.1.2.15Integer32read-onlyThis parameter counts the total number of end-points that were configured with Continuity Check (CC).
I32 atmNteTotalPm1.3.6.1.4.1.164.12.3.1.2.16Integer32read-onlyThis parameter counts the total number of end-points that were configured with PM.
atmNtePrt1.3.6.1.4.1.164.12.3.2
atmNtePrtConfig1.3.6.1.4.1.164.12.3.2.1
atmNteConfIfTable1.3.6.1.4.1.164.12.3.2.1.1not-accessibleThe Physical interface configuration table.
atmNteConfIfEntry1.3.6.1.4.1.164.12.3.2.1.1.1not-accessibleAn entry in the Physical interface configuration table. The ifIndex is of the lowest physical layer.
INT atmConfIfTransmitClk1.3.6.1.4.1.164.12.3.2.1.1.1.1INTEGERread-writeThe transmit clock of the port.
INT atmConfIfLoopback1.3.6.1.4.1.164.12.3.2.1.1.1.2INTEGERread-writeInterface Loopback.
INT atmConfIfFrameType1.3.6.1.4.1.164.12.3.2.1.1.1.3INTEGERread-writeThe frame type. Valid values for a 155M interface: sonet(2), sdh(3). Valid values for a T3 interface: direct(4), plcpInternal(5), plcpExternal(6), directNoScrmbling(10), plcpInternalNoScrmbling(11), plcpExternalNoScrmbling(12). Valid values for Ethernet interface: ethCrcTrans (8), ethCrcNotTrans(9). (DS1 interfaces frame type is specified in the DSX1 mib).
INT atmConfIfCardType1.3.6.1.4.1.164.12.3.2.1.1.1.4INTEGERread-onlyThe card type.
INT atmConfAtmIfVpiVciLimit1.3.6.1.4.1.164.12.3.2.1.1.1.5INTEGERread-onlyThe limit on the sum of the VPI+VCI bits for this interface.
INT atmConfIfHwFeatures1.3.6.1.4.1.164.12.3.2.1.1.1.6INTEGERread-writeHW features command.
I32 atmConfIfOutputRate1.3.6.1.4.1.164.12.3.2.1.1.1.7Integer32read-writeThis parameter indicates the output rate in cells/sec, which is supported per port. Successfully setting this parameter is dependent on all other ports values calculations, which are described in the NMS SRS.
I32 atmConfIfInputRate1.3.6.1.4.1.164.12.3.2.1.1.1.8Integer32read-writeThis parameter indicates the input rate in cells/sec, which is supported per port. Successfully setting this parameter is dependent on all other ports values calculations, which are described in the NMS SRS.
INT atmConfAlarmForwarding1.3.6.1.4.1.164.12.3.2.1.1.1.9INTEGERread-writeEnables Path AIS Alarm forwarding upon a failure detection. The following might be considered as a failure: LOS, LOF, LOC, SLM, LOP, Path AIS and Line AIS. disable(2) - will not forward an alarm upon a failure on this port. enable(3) - will forward an alarm upon a failure on this port.
I32 atmConfIfAllocatedBw1.3.6.1.4.1.164.12.3.2.1.1.1.10Integer32read-onlyTotal VC Bandwidth Allocation.
I32 atmConfIfLowerVpi1.3.6.1.4.1.164.12.3.2.1.1.1.11Integer32read-writeThe Lower possible VPI.
INT atmConfIfOamMode1.3.6.1.4.1.164.12.3.2.1.1.1.12INTEGERread-writeOAM support Mode, which determines the interface's location in a segment wise.
INT atmConfIfOamFailureInd1.3.6.1.4.1.164.12.3.2.1.1.1.13INTEGERread-writeThis object allows user to define the type of indication (if any) that will be created upon a LB cell failure, for all VCs on which OAM loopback traffic is activated. disabled(2) - no indication will be created. ais(3) - will cause Tx of AIS. rdi(4) - will cause Tx of RDI. aisAndRdi(5) - will cause Tx of AIS & RDI. For LA-110, indication will be sent only for VCs with atmConfVcLoopbackFailureInd <> disabled
atmNteAlarmIfTable1.3.6.1.4.1.164.12.3.2.1.2not-accessibleThe interface Alarm table.
atmNteAlarmIfEntry1.3.6.1.4.1.164.12.3.2.1.2.1not-accessibleAn entry in the interface Alarm table.
I32 atmInterfaceActiveAlarms1.3.6.1.4.1.164.12.3.2.1.2.1.1Integer32read-onlyA Bit String of the active alarms on this interface. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - LOS 2 - LOF 3 - Line AIS (SONET)/ PLCP LOF (DS3) 4 - LOP 5 - Path AIS 6 - SLM 7 - LCD 8 - Line RDI (SONET)/ PLCP Yellow (DS3) 9 - Path RDI (SONET)/ RDI (DS3) 10 - Section BIP (SONET)/ P1/P2 (DS3) > Threshold 11 - Line BIP (SONET)/ PLCP BIP (DS3) > Threshold 12 - Line FEBE (SONET)/ PLCP FEBE (DS3) > Threshold 13 - Path BIP > Threshold 14 - Path FEBE > Threshold 15 - HW Failure
I32 atmThresholdSectionBIP1.3.6.1.4.1.164.12.3.2.1.2.1.2Integer32read-writeWhen Section BIPs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface.
I32 atmThresholdLineBIP1.3.6.1.4.1.164.12.3.2.1.2.1.3Integer32read-writeWhen Line BIPs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface.
I32 atmThresholdLineFEBE1.3.6.1.4.1.164.12.3.2.1.2.1.4Integer32read-writeWhen Line FEBEs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface.
I32 atmThresholdPathBIP1.3.6.1.4.1.164.12.3.2.1.2.1.5Integer32read-writeWhen Path BIPs are greater than this threshold, an active alarm is raised.
I32 atmThresholdPathFEBE1.3.6.1.4.1.164.12.3.2.1.2.1.6Integer32read-writeWhen Path FEBEs are greater than this threshold, an active alarm is raised.
I32 atmThresholdErroredCells1.3.6.1.4.1.164.12.3.2.1.2.1.7Integer32read-writeWhen Errored Cells are greater than this threshold, an active alarm is raised.
I32 atmThresholdLostCells1.3.6.1.4.1.164.12.3.2.1.2.1.8Integer32read-writeWhen Lost Cells are greater than this threshold, an active alarm is raised.
I32 atmThresholdMisinsertedCells1.3.6.1.4.1.164.12.3.2.1.2.1.9Integer32read-writeWhen Misinserted Cells are greater than this threshold, an active alarm is raised.
INT atmInterfaceAlarmStatus1.3.6.1.4.1.164.12.3.2.1.2.1.10INTEGERread-onlyThe variable is on(3) when there is any active alarm on this interface.
I32 atmInterfaceMaskAlarms1.3.6.1.4.1.164.12.3.2.1.2.1.11Integer32read-writeA Bit String of alarms mask on this interface. An up bit (1) means that the respective alarm is masked. A down bit (0) means no mask. The mask is supported for the following alarms: 1 - LOS
atmNteConfVpTable1.3.6.1.4.1.164.12.3.2.1.3not-accessibleThe ATM VP configuration table. The table is an extension to the atmVplTable of RFC-1695.
atmNteConfVpEntry1.3.6.1.4.1.164.12.3.2.1.3.1not-accessibleAn entry in the ATM VP configuration table. ifIndex of the ATM layer.
INT atmConfVpPolicing1.3.6.1.4.1.164.12.3.2.1.3.1.1INTEGERread-writePolicing method desired for this VPL.
INT atmConfVpCCAdminStatus1.3.6.1.4.1.164.12.3.2.1.3.1.2INTEGERread-writeup(2) - Activate Continuity Check (CC). down(3) - Deactivate CC. source(4) - Activate OAM CC(Continuity Check) of local agent ( start sending Oam cells to the remote side ). sink(5) - Activate CC of remote agent ( start receiving Oam cells from remote side ). listenToActivationCells (6) - Passive listener till gets an activation request originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection.
INT atmConfVpLoopbackAdminStatus1.3.6.1.4.1.164.12.3.2.1.3.1.3INTEGERread-writeup(2) - Start loopback OAM cells. down(3) - Stop sending loopback OAM cells. For ace2002: up(2) - Transmitting LB cells with llid all ones (i.e. FFFF..FF) down(3) - Not transmitting LB cells. llid(4) - Transmitting LB cells with llid indicated in the address field. segment(5) - Transmitting Segment LB cells with llid all ones. endToEnd(6) - Transmitting End to End LB cells with llid all ones. segmentLlid(7) - Transmitting Segment LB cells with llid indicated in the address field. endToEndLlid(8) - Transmitting LB cells with llid indicated in the address field. This parameter value might be in conflict with atmConfVpOamSupport value, since this parameter is for LB, while atmConfVpOamSupport is for any other OAM cells.
OCT atmConfVpLoopbackSinkAddress1.3.6.1.4.1.164.12.3.2.1.3.1.4OCTET STRINGread-writeDestination address. For ace101: 2 bytes are used. For ace2002: 16 bytes are used.
OCT atmConfVpCongestionControl1.3.6.1.4.1.164.12.3.2.1.3.1.5OCTET STRINGread-writeEach bit indicates a selection of one option as the following description. All combinations are possible and legal. The codes are: 1 - EPD 2 - CLP 4 - EFCI
INT atmConfVpCCDirection1.3.6.1.4.1.164.12.3.2.1.3.1.6INTEGERread-writeboth(2) - Agent send OAM CC cells and check received OAM CC cells source(4)- Agent send OAM CC cells. sink(5) - Agent checks received OAM CC cells.
DAT atmConfVpCreationTime1.3.6.1.4.1.164.12.3.2.1.3.1.7DateAndTimeread-onlyA date-time in which the VP was created.
INT atmConfVpOamSupport1.3.6.1.4.1.164.12.3.2.1.3.1.8INTEGERread-writeOAM support mode, which determines the device location in a segment wise.
INT atmConfVpCCOperStatus1.3.6.1.4.1.164.12.3.2.1.3.1.9INTEGERread-onlyinitial(1) - The CC activation process is not started. source(4) - Agent sends OAM CC cells. sink(5) - Agent checks received OAM CC cells. both (8) - OAM CC of local and remote agents activation. timeout (9) - Timeout occured on receiving answer from the remote agent. denied (10) - CC activation process rejected by remote agent. conflict (11) - local and remote sides requested activation simultaneously. manual (12) - OAM CC of local agent activated manually.
INT atmConfVpLoopbackTraffic1.3.6.1.4.1.164.12.3.2.1.3.1.10INTEGERread-writeThis parameter has both command and status meanings: off(2) - Set to 'Off' will Stop traffic loop. Getting this value means that the loop is not running. on (3) - Set to 'On' will start traffic loop. Getting this value means that the loop is currently running.
INT atmConfVpLoopbackFailureInd1.3.6.1.4.1.164.12.3.2.1.3.1.11INTEGERread-writeThis object allows user to define the Indication that will be created upon a LB cell failure. disabled(2) - no indication will be created. segmentAis(3) - will cause Tx of a segment AIS. segmentRdi(4) - will cause Tx of a segment RDI. segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI. endToEndAis(6) - will cause Tx of an End to End AIS. endToEndRdi(7) - will cause Tx of an End to End RDI. endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI. Default: disabled(2).
I32 atmConfVpLoopbackFailureThreshold1.3.6.1.4.1.164.12.3.2.1.3.1.12Integer32read-writeThe number of the LB failures before starting transmission of the Indication defined by atmConfVcLoopbackFailureInd. Range: 1..16. Default: 1.
INT atmConfVpOamDirection1.3.6.1.4.1.164.12.3.2.1.3.1.13INTEGERread-writeThe direction of OAM cell insertion. downStream(2) - The OAM cell will be inserted in downStream. upStream(3) - The OAM cell will be inserted in upStream.
I32 atmConfVpOamDescrIndex1.3.6.1.4.1.164.12.3.2.1.3.1.14Integer32read-writeThis parameter indicates the VPL's OAM Descriptor index, according to the OAM Descriptor Configuration Table.
INT atmConfVpConnected1.3.6.1.4.1.164.12.3.2.1.3.1.15INTEGERread-writeThis object indicates whether this VP is connected and if connected, what is it connected to.
atmNteAlarmVpTable1.3.6.1.4.1.164.12.3.2.1.5not-accessibleThe ATM VP Alarm table.
atmNteAlarmVpEntry1.3.6.1.4.1.164.12.3.2.1.5.1not-accessibleAn entry in the ATM VP Alarm table. ifIndex of the ATM layer.
I32 atmNteVpAlarmVpi1.3.6.1.4.1.164.12.3.2.1.5.1.1Integer32read-onlyThe VPI on which there is an active alarm.
I32 atmNteVpActiveAlarms1.3.6.1.4.1.164.12.3.2.1.5.1.2Integer32read-onlyA Bit String of the active alarms on this VP. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - VP AIS 2 - VP Loss Of Continuity 3 - VP RDI Reception 4 - VP Errored Cells > Threshold 5 - VP Lost Cells > Threshold 6 - VP Misinserted Cells > Threshold 9 - VP Loopback Failure
atmNteAlarmVcTable1.3.6.1.4.1.164.12.3.2.1.6not-accessibleThe ATM VC Alarm table.
atmNteAlarmVcEntry1.3.6.1.4.1.164.12.3.2.1.6.1not-accessibleAn entry in the ATM VC Alarm table. ifIndex of the ATM layer.
I32 atmNteVcAlarmVpi1.3.6.1.4.1.164.12.3.2.1.6.1.1Integer32read-onlyThe VPI of the VC on which there is an active alarm.
I32 atmNteVcAlarmVci1.3.6.1.4.1.164.12.3.2.1.6.1.2Integer32read-onlyThe VCI of the VC on which there is an active alarm.
I32 atmNteVcActiveAlarms1.3.6.1.4.1.164.12.3.2.1.6.1.3Integer32read-onlyA Bit String of the active alarms on this VC. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - VC AIS 2 - VC Loss Of Continuity 3 - VC RDI 4 - VC Errored Cells > Threshold 5 - VC Lost Cells > Threshold 6 - VC Misinserted Cells > Threshold 7 - Tx VC AIS 8 - Tx VC RDI 9 - VC Loopback Failure
atmNteLoopback1.3.6.1.4.1.164.12.3.2.2
atmLoopbackVpTable1.3.6.1.4.1.164.12.3.2.2.1not-accessibleThis table contains parameters for an OAM VP loopback test.
atmLoopbackVpEntry1.3.6.1.4.1.164.12.3.2.2.1.1not-accessibleAn entry in table atmLoopbackVpTable.
I32 atmLoopbackVpIfIndex1.3.6.1.4.1.164.12.3.2.2.1.1.1Integer32read-onlyThe interface index of the ATM layer.
I32 atmLoopbackVpVpi1.3.6.1.4.1.164.12.3.2.2.1.1.2Integer32read-onlyThe VPI of the OAM VPL.
INT atmLoopbackVpOperStatus1.3.6.1.4.1.164.12.3.2.2.1.1.3INTEGERread-only-noActive(1) means that the loopback test has not been activated for this VP. -inProgress(2) means that the test has been activated and there is currently no problem. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was stopped and all was OK.
I32 atmLoopbackVpCDV1.3.6.1.4.1.164.12.3.2.2.1.1.4Integer32read-onlyCell Delay Variation for this sampling.
I32 atmLoopbackVpAverageDelay1.3.6.1.4.1.164.12.3.2.2.1.1.5Integer32read-onlyAverage delay without including lost cells.
I32 atmLoopbackVpMaxDelay1.3.6.1.4.1.164.12.3.2.2.1.1.6Integer32read-onlyMaximum delay without including lost cells.
I32 atmLoopbackVpMinDelay1.3.6.1.4.1.164.12.3.2.2.1.1.7Integer32read-onlyMinimum delay.
I32 atmLoopbackVpErrSessions1.3.6.1.4.1.164.12.3.2.2.1.1.8Integer32read-onlyErrored Sessions. Will be updated once in 5 seconds.
atmLoopbackVcTable1.3.6.1.4.1.164.12.3.2.2.2not-accessibleThis table contains parameters for an OAM VC loopback test.
atmLoopbackVcEntry1.3.6.1.4.1.164.12.3.2.2.2.1not-accessibleAn entry in table.
I32 atmLoopbackVcIfIndex1.3.6.1.4.1.164.12.3.2.2.2.1.1Integer32read-onlyThe interface index of the ATM layer.
I32 atmLoopbackVcVpi1.3.6.1.4.1.164.12.3.2.2.2.1.2Integer32read-onlyThe VPI of the OAM VCL.
I32 atmLoopbackVcVci1.3.6.1.4.1.164.12.3.2.2.2.1.3Integer32read-onlyThe VCI of the OAM VCL.
INT atmLoopbackVcOperStatus1.3.6.1.4.1.164.12.3.2.2.2.1.4INTEGERread-only-noActive(1) means that the loopback test has not been activated for this VP. -inProgress(2) means that the test has been activated and there is currently no problem. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was stopped and all was OK.
I32 atmLoopbackVcCDV1.3.6.1.4.1.164.12.3.2.2.2.1.5Integer32read-onlyCell Delay Variation for this sampling.
I32 atmLoopbackVcAverageDelay1.3.6.1.4.1.164.12.3.2.2.2.1.6Integer32read-onlyAverage delay without including lost cells.
I32 atmLoopbackVcMaxDelay1.3.6.1.4.1.164.12.3.2.2.2.1.7Integer32read-onlyThe maximum delay without including lost cells.
I32 atmLoopbackVcMinDelay1.3.6.1.4.1.164.12.3.2.2.2.1.8Integer32read-onlyThe minimum delay.
I32 atmLoopbackVcErrSessions1.3.6.1.4.1.164.12.3.2.2.2.1.9Integer32read-onlyErrored Sessions. Will be updated once in 5 seconds.
atmLoopbackVpIvlTable1.3.6.1.4.1.164.12.3.2.2.3not-accessibleThis table contains parameters for an OAM VP loopback test, according interval number.
atmLoopbackVpIvlEntry1.3.6.1.4.1.164.12.3.2.2.3.1not-accessibleAn entry in table.
I32 atmLoopbackVpIvlIfIndex1.3.6.1.4.1.164.12.3.2.2.3.1.1Integer32read-onlyThe interface index of the ATM layer.
I32 atmLoopbackVpIvlVpi1.3.6.1.4.1.164.12.3.2.2.3.1.2Integer32read-onlyThe VPI of the OAM VPL.
I32 atmLoopbackVpIvlIvl1.3.6.1.4.1.164.12.3.2.2.3.1.3Integer32read-onlyThe relevant interval number.
INT atmLoopbackVpIvlOperStatus1.3.6.1.4.1.164.12.3.2.2.3.1.4INTEGERread-only-noActive(1) means that the loopback test has not been activated for this VP during this interval. -inProgress(2) has no meaning for an ended interval. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was OK.
I32 atmLoopbackVpIvlCDV1.3.6.1.4.1.164.12.3.2.2.3.1.5Integer32read-onlyCell Delay Variation for this interval.
I32 atmLoopbackVpIvlAverageDelay1.3.6.1.4.1.164.12.3.2.2.3.1.6Integer32read-onlyAverage delay without including lost cells for this interval.
I32 atmLoopbackVpIvlMaxDelay1.3.6.1.4.1.164.12.3.2.2.3.1.7Integer32read-onlyThe maximum delay without including lost cells for this interval.
I32 atmLoopbackVpIvlMinDelay1.3.6.1.4.1.164.12.3.2.2.3.1.8Integer32read-onlyThe minimum delay for this interval.
I32 atmLoopbackVpIvlErrSessions1.3.6.1.4.1.164.12.3.2.2.3.1.9Integer32read-onlyErrored Sessions. Will be updated once in 5 seconds.
atmLoopbackVcIvlTable1.3.6.1.4.1.164.12.3.2.2.4not-accessibleThis table contains parameters for an OAM VC loopback test.
atmLoopbackVcIvlEntry1.3.6.1.4.1.164.12.3.2.2.4.1not-accessibleAn entry in table.
I32 atmLoopbackVcIvlIfIndex1.3.6.1.4.1.164.12.3.2.2.4.1.1Integer32read-onlyThe interface index of the ATM layer.
I32 atmLoopbackVcIvlVpi1.3.6.1.4.1.164.12.3.2.2.4.1.2Integer32read-onlyThe VPI of the OAM VCL.
I32 atmLoopbackVcIvlVci1.3.6.1.4.1.164.12.3.2.2.4.1.3Integer32read-onlyThe VCI of the OAM VCL.
I32 atmLoopbackVcIvlIvl1.3.6.1.4.1.164.12.3.2.2.4.1.4Integer32read-onlyThe relevant interval number.
INT atmLoopbackVcIvlOperStatus1.3.6.1.4.1.164.12.3.2.2.4.1.5INTEGERread-only-noActive(1) means that the loopback test has not been activated for this VC during this interval. -inProgress(2) has no meaning per interval. -failed(3) means there was problem for this test during this interval. -endSuccessfully(4) means that the test was OK.
I32 atmLoopbackVcIvlCDV1.3.6.1.4.1.164.12.3.2.2.4.1.6Integer32read-onlyCell Delay Variation for this interval.
I32 atmLoopbackVcIvlAverageDelay1.3.6.1.4.1.164.12.3.2.2.4.1.7Integer32read-onlyAverage delay without including lost cells.
I32 atmLoopbackVcIvlMaxDelay1.3.6.1.4.1.164.12.3.2.2.4.1.8Integer32read-onlyThe maximum delay without including lost cells.
I32 atmLoopbackVcIvlMinDelay1.3.6.1.4.1.164.12.3.2.2.4.1.9Integer32read-onlyThe minimum delay.
I32 atmLoopbackVcIvlErrSessions1.3.6.1.4.1.164.12.3.2.2.4.1.10Integer32read-onlyErrored Sessions. Will be updated once in 5 seconds.
atmNtePM1.3.6.1.4.1.164.12.3.2.3
atmVpPmTable1.3.6.1.4.1.164.12.3.2.3.1not-accessibleThis table contains parameters for VP performance monitoring.
atmVpPmEntry1.3.6.1.4.1.164.12.3.2.3.1.1not-accessibleAn entry in table.
I32 atmVpPmIfIndex1.3.6.1.4.1.164.12.3.2.3.1.1.1Integer32read-onlyThe interface index of the ATM layer.
I32 atmVpPmVpi1.3.6.1.4.1.164.12.3.2.3.1.1.2Integer32read-onlyThe VPI of the Performance Monitoring VPL.
INT atmVpPmAdminStatus1.3.6.1.4.1.164.12.3.2.3.1.1.3INTEGERread-createup(2) - Activate PM. down(3) - Deactivate PM. listenToActivationCells(4) - . originateActivationCells(5) - .
INT atmVpPmDirection1.3.6.1.4.1.164.12.3.2.3.1.1.4INTEGERread-createThe direction of PM.
I32 atmVpPmBlockSize1.3.6.1.4.1.164.12.3.2.3.1.1.5Integer32read-createValid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768.
ROW atmVpPmRowStatus1.3.6.1.4.1.164.12.3.2.3.1.1.6RowStatusread-createCreation/Deletion of rows in the table.
INT atmVpPmSink1.3.6.1.4.1.164.12.3.2.3.1.1.7INTEGERread-createoff (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
INT atmVpPmSource1.3.6.1.4.1.164.12.3.2.3.1.1.8INTEGERread-createoff (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
atmVcPmTable1.3.6.1.4.1.164.12.3.2.3.2not-accessibleThis table contains parameters for VC performance monitoring.
atmVcPmEntry1.3.6.1.4.1.164.12.3.2.3.2.1not-accessibleAn entry in table.
I32 atmVcPmIfIndex1.3.6.1.4.1.164.12.3.2.3.2.1.1Integer32read-onlyThe interface index of the ATM layer.
I32 atmVcPmVpi1.3.6.1.4.1.164.12.3.2.3.2.1.2Integer32read-onlyThe VPI of the Performance Monitoring VCL.
I32 atmVcPmVci1.3.6.1.4.1.164.12.3.2.3.2.1.3Integer32read-onlyThe VCI of the PM VCL.
INT atmVcPmAdminStatus1.3.6.1.4.1.164.12.3.2.3.2.1.4INTEGERread-createup(2) - Activate PM. down(3) - Deactivate PM. listenToActivationCells(4) - . originateActivationCells(5) - .
INT atmVcPmDirection1.3.6.1.4.1.164.12.3.2.3.2.1.5INTEGERread-createThe direction of PM.
I32 atmVcPmBlockSize1.3.6.1.4.1.164.12.3.2.3.2.1.6Integer32read-createValid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768.
ROW atmVcPmRowStatus1.3.6.1.4.1.164.12.3.2.3.2.1.7RowStatusread-createCreation/Deletion of rows in the table.
INT atmVcPmSink1.3.6.1.4.1.164.12.3.2.3.2.1.8INTEGERread-createoff (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
INT atmVcPmSource1.3.6.1.4.1.164.12.3.2.3.2.1.9INTEGERread-createoff (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
atmNteMdl1.3.6.1.4.1.164.12.3.3
atmNteMdlConfig1.3.6.1.4.1.164.12.3.3.1
atmNteMdlConfigTable1.3.6.1.4.1.164.12.3.3.1.1not-accessibleModule configuration table.
atmNteMdlConfigEntry1.3.6.1.4.1.164.12.3.3.1.1.1not-accessibleThere is an entry in this table just for those modules that have parameters that are relevant to module level only.
I32 atmNteMdlSlotIndex1.3.6.1.4.1.164.12.3.3.1.1.1.1Integer32not-accessibleThe slot number.
INT atmNteMdlPrtCpuSharing1.3.6.1.4.1.164.12.3.3.1.1.1.2INTEGERread-writeThis object lets the user decide what will be the CPU sharing between the ports of the module. This object is applicable for modules in which the same CPU handles the traffic of all ports. equal - All ports will have the same CPU resource. port1 - Port 1 will have higher priority than the other ports.
INT atmNteMdlInputPriorityMechanism1.3.6.1.4.1.164.12.3.3.1.1.1.3INTEGERread-writeThis object allows the user to Enable/Disable the Input priority mechanism. This object is applicable for modules with more than one port, in which the total ports input may be greater than the port output. disabled - all LAN VCCs will be transmitted through the same queue (queue 1). Upon congestion frames will be dropped randomly. enabled - the user should configure each port/connection priority. Upon congestion frames will be dropped according to priority.

RFC description

RAD Data Communications enterprise MIB for WAN access device management.

Start monitoring RAD Data Communications access/transmission/multiplexer equipment, entire product line (base enterprise MIB) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download RAD-MIB