RAD-MIB :: prtGenTsIConPrt

MIB Reference — IPNetwork Monitor

All MIBsRAD-MIBprtGenTsIConPrt

prtGenTsIConPrt

Module: RAD-MIB

OID (symbolic): RAD-MIB::prtGenTsIConPrt

OID (numeric): 1.3.6.1.4.1.164.3.3.3.1.3.1.5

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description:

This attribute indicates the internally (In Mux) connected port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside ports will be for example, the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . * noConnection - will be indicated as 10 for DXC and FCD-E1/T1. - will be indicated as 100 for FCD-E1/I and SMODs. * Split TS (same TS is Split to several ports) - 11. * notApplicable- will be indicated as 100 for LRS IMODs.

All HS port's timeslots must have the same destination port.

What is prtGenTsIConPrt?

This parameter specifies which internal crossconnect port an E1/T1 time slot is connected to within a DXC (Digital Cross-Connect) unit's multiplexer, following RAD convention for port numbering based on IO slot number and card type. The valid port ranges depend on the installed hardware configuration. An operator would set this to establish internal circuit paths through the DXC, enabling traffic routing between external ports and internal switching matrices.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.3.3.1.3.1.5
snmpwalk -v2c -c public <target> RAD-MIB::prtGenTsIConPrt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.3.3.1.3.1.5.1
snmpget -v2c -c public <target> RAD-MIB::prtGenTsIConPrt.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.164.3.3.3.1.3.1.5.1 i <value>

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.3dacsMuxDACS-MIB
1.3.6.1.4.1.164.3.3.3prtDacsMuxDACS-MIB
1.3.6.1.4.1.164.3.3.3.1prtGenDACS-MIB
1.3.6.1.4.1.164.3.3.3.1.3prtGenTsTableDACS-MIB
1.3.6.1.4.1.164.3.3.3.1.3.1prtGenTsEntryDACS-MIB
1.3.6.1.4.1.164.3.3.3.1.3.1.5prtGenTsIConPrtRAD-MIB