All MIBs › RAD-MIB › prtExTsTxSignaling
prtExTsTxSignaling
Module: RAD-MIB
OID (symbolic): RAD-MIB::prtExTsTxSignaling
OID (numeric): 1.3.6.1.4.1.164.3.1.4.2.1.1.9
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-only
Description:
Link - Tx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is sent to Link for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.1.4.2.1.1.9 snmpwalk -v2c -c public <target> RAD-MIB::prtExTsTxSignaling
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.1.4.2.1.1.9.1 snmpget -v2c -c public <target> RAD-MIB::prtExTsTxSignaling.1
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.164 | rad | DACS-MIB |
| 1.3.6.1.4.1.164.3 | radWan | DACS-MIB |
| 1.3.6.1.4.1.164.3.1 | wanGen | DACS-MIB |
| 1.3.6.1.4.1.164.3.1.4 | prtWanGen | DACS-MIB |
| 1.3.6.1.4.1.164.3.1.4.2 | cnfgPrtGen | DACS-MIB |
| 1.3.6.1.4.1.164.3.1.4.2.1 | prtExTsSplitTable | DACS-MIB |
| 1.3.6.1.4.1.164.3.1.4.2.1.1 | prtExTsSplitEntry | DACS-MIB |
| 1.3.6.1.4.1.164.3.1.4.2.1.1.9 | prtExTsTxSignaling | RAD-MIB |