RAD-MIB :: prtExPVc4SeizeAck

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsRAD-MIBprtExPVc4SeizeAck

prtExPVc4SeizeAck

Module: RAD-MIB

OID (symbolic): RAD-MIB::prtExPVc4SeizeAck

OID (numeric): 1.3.6.1.4.1.164.3.2.3.2.9.1.1.23

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal.

Example: If Seize Ack Parameter = YES, when the MVC.4 receives a seize signal (Off Hook) from the PBX it will send an Off Hook to the PBX.

The Seize Parameter is relevant for all the following cards: MVC-4 MVC-4/E1-Framer MVC-4/T1-DSU-Framer MVC-4/T1-CSU-Framer MVC-4/E1-SLAVE MVC-4/T1-SLAVE

Default values: Analog FXS - No (value can't be changed). Analog FXO - Yes (value can't be changed). Analog E&M - No (values NO/YES). Digital E1/T1 Framer & Slave - No.

What is prtExPVc4SeizeAck?

This object controls whether the MVC.4 voice card will acknowledge an on-hook or off-hook signal received from a PBX by transmitting a matching signal back. When set to 'yes', the device echoes the seize signal; when set to 'no', it ignores the signal without responding. An operator configures this based on the PBX integration requirements and signal protocol expectations.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.2.3.2.9.1.1.23
snmpwalk -v2c -c public <target> RAD-MIB::prtExPVc4SeizeAck

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.2.3.2.9.1.1.23.1
snmpget -v2c -c public <target> RAD-MIB::prtExPVc4SeizeAck.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.164.3.2.3.2.9.1.1.23.1 i <value>

Start monitoring RAD Data Communications access/transmission/multiplexer equipment, entire product line (base enterprise MIB) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAD-MIB::prtExPVc4SeizeAck OID value, configure state conditions and alerts, and monitor any RAD Data Communications access/transmission/multiplexer equipment, entire product line (base enterprise MIB) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.2muxHubDACS-MIB
1.3.6.1.4.1.164.3.2.3prtMuxDACS-MIB
1.3.6.1.4.1.164.3.2.3.2cnfgPrtMuxDACS-MIB
1.3.6.1.4.1.164.3.2.3.2.9prtPVc4CnfgDACS-MIB
1.3.6.1.4.1.164.3.2.3.2.9.1prtExPVc4CnfgTableDACS-MIB
1.3.6.1.4.1.164.3.2.3.2.9.1.1prtExPVc4CnfgEntryDACS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.164.3.2.3.2.9.1.1.23prtExPVc4SeizeAckRAD-MIB