RAD-MIB :: dsx1IntervalLOCRCMF

MIB Reference — IPNetwork Monitor

All MIBsRAD-MIBdsx1IntervalLOCRCMF

dsx1IntervalLOCRCMF

Module: RAD-MIB

OID (symbolic): RAD-MIB::dsx1IntervalLOCRCMF

OID (numeric): 1.3.6.1.4.1.164.3.1.6.4.1.3.1.10

Node type: OBJECT-TYPE

Type: PerfIntervalCount

Access: read-only

Description:

Loss of CRC4 Multi-Frame sequence in E1.

What is dsx1IntervalLOCRCMF?

This object counts the number of Loss of CRC4 Multi-Frame sequence (LRCMF) errors detected on an E1 (European 2 Mbps) channel during a specific 15-minute interval. The CRC4 frame format enables error detection on E1 lines. An operator would monitor this counter to track E1 line quality and detect framing synchronization issues.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.4.1.3.1.10
snmpwalk -v2c -c public <target> RAD-MIB::dsx1IntervalLOCRCMF

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.4.1.3.1.10.1
snmpget -v2c -c public <target> RAD-MIB::dsx1IntervalLOCRCMF.1

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.1wanGenDACS-MIB
1.3.6.1.4.1.164.3.1.6diverseIfWanGenDACS-MIB
1.3.6.1.4.1.164.3.1.6.4ds1InterfaceRAD-DS1-MIB
1.3.6.1.4.1.164.3.1.6.4.1prtDs1PerfHistoryRAD-DS1-MIB
1.3.6.1.4.1.164.3.1.6.4.1.3dsx1XIntervalTableRAD-DS1-MIB
1.3.6.1.4.1.164.3.1.6.4.1.3.1dsx1XIntervalEntryRAD-DS1-MIB
1.3.6.1.4.1.164.3.1.6.4.1.3.1.10dsx1IntervalLOCRCMFRAD-MIB