RAD-MIB :: agnNoOfCurrentConns

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsRAD-MIBagnNoOfCurrentConns

agnNoOfCurrentConns

Module: RAD-MIB

OID (symbolic): RAD-MIB::agnNoOfCurrentConns

OID (numeric): 1.3.6.1.4.1.164.6.2.48

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: This variable indicates the number of connections currently configured for the agent.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.6.2.48
snmpwalk -v2c -c public <target> RAD-MIB::agnNoOfCurrentConns

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.6.2.48.1
snmpget -v2c -c public <target> RAD-MIB::agnNoOfCurrentConns.1

Start monitoring RAD Data Communications access/transmission/multiplexer equipment, entire product line (base enterprise MIB) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAD-MIB::agnNoOfCurrentConns OID value, configure state conditions and alerts, and monitor any RAD Data Communications access/transmission/multiplexer equipment, entire product line (base enterprise MIB) from a single console.

How to Use in IPNetwork Monitor

Select a RAD Data Communications access, transmission, or multiplexer device as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type agnNoOfCurrentConns into the Find box to locate it in the OID tree, then select it and click OK. It reports the current number of connections configured on this agent. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the count changes from its expected baseline, since that would indicate a connection was added or removed unexpectedly. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.6radGenDACS-MIB
1.3.6.1.4.1.164.6.2agntDACS-MIB
Numeric OIDNameModule