RAD-MIB :: dot3OamPeerEvent

MIB Reference — IPNetwork Monitor

All MIBsRAD-MIBdot3OamPeerEvent

dot3OamPeerEvent

Module: RAD-MIB

OID (symbolic): RAD-MIB::dot3OamPeerEvent

OID (numeric): 1.3.6.1.4.1.164.3.1.6.1.6.0.2

Node type: NOTIFICATION-TYPE

Description:

This trap is sent when value of dot3OamXPeerState changes from any value to one of the following values: linkFault, dyingGasp, criticalEvent. This trap has no recovery (clearing value).

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' RAD-MIB::dot3OamPeerEvent
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.164.3.1.6.1.6.0.2

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:60431->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (66950671) 7 days, 17:58:26.71
  SNMPv2-MIB::snmpTrapOID.0 = OID: RAD-MIB::dot3OamPeerEvent

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.1wanGenDACS-MIB
1.3.6.1.4.1.164.3.1.6diverseIfWanGenDACS-MIB
1.3.6.1.4.1.164.3.1.6.1ethIfDACS-MIB
1.3.6.1.4.1.164.3.1.6.1.6ethIfOamEfmRAD-MIB
1.3.6.1.4.1.164.3.1.6.1.6.0dot3OamEventsRAD-MIB
1.3.6.1.4.1.164.3.1.6.1.6.0.2dot3OamPeerEventRAD-MIB