RAD-MIB :: sysSClkSrc

MIB Reference — IPNetwork Monitor

All MIBsRAD-MIBsysSClkSrc

sysSClkSrc

Module: RAD-MIB

OID (symbolic): RAD-MIB::sysSClkSrc

OID (numeric): 1.3.6.1.4.1.164.3.3.1.3.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description:

This entry indicates the source of the system clock.

What is sysSClkSrc?

This object identifies which clock source is currently being used to synchronize the system time, with options including master (primary), fallback (secondary), internal, or manual (ML) sources. The system automatically selects among available sources based on signal quality and availability. Network and telecom operators monitor this to ensure reliable timing, particularly in systems where synchronization is critical for data or voice services.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.3.1.3.7
snmpwalk -v2c -c public <target> RAD-MIB::sysSClkSrc

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.3.1.3.7.1
snmpget -v2c -c public <target> RAD-MIB::sysSClkSrc.1

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.3dacsMuxDACS-MIB
1.3.6.1.4.1.164.3.3.1systemDacsMuxDACS-MIB
1.3.6.1.4.1.164.3.3.1.3sysStatusDACS-MIB
1.3.6.1.4.1.164.3.3.1.3.7sysSClkSrcRAD-MIB