All MIBs › RAD-MIB › prtExPVc4WinkMinDuration
prtExPVc4WinkMinDuration
Module: RAD-MIB
OID (symbolic): RAD-MIB::prtExPVc4WinkMinDuration
OID (numeric): 1.3.6.1.4.1.164.3.2.3.2.9.1.1.26
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description:
This parameter is used only for Wink Protocol. Min Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.2.3.2.9.1.1.26 snmpwalk -v2c -c public <target> RAD-MIB::prtExPVc4WinkMinDuration
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.2.3.2.9.1.1.26.1 snmpget -v2c -c public <target> RAD-MIB::prtExPVc4WinkMinDuration.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.164.3.2.3.2.9.1.1.26.1 i <value>