All MIBs › RAD-MIB › radMepTransmitLtmTargetIsMepId
radMepTransmitLtmTargetIsMepId
Module: RAD-MIB
OID (symbolic): RAD-MIB::radMepTransmitLtmTargetIsMepId
OID (numeric): 1.3.6.1.4.1.164.3.1.6.1.3.1.1.31
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-create
Description:
yes (3) indicates that MEPID of the target MEP is used for Linktrace transmission. no (2) indicates that unicast destination MAC address of the target MEP is used. 802.1ag clause 12.14.7.4.2:c.
What is radMepTransmitLtmTargetIsMepId?
This object determines whether linktrace messages target a remote Maintenance End Point (MEP) by its MEPID or by unicast MAC address, per IEEE 802.1ag Connectivity Fault Management. Setting yes(3) uses MEPID-based targeting; no(2) uses destination MAC addresses. This controls the lookup method for tracing paths through Ethernet OAM domains.
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.164 | rad | DACS-MIB |
| 1.3.6.1.4.1.164.3 | radWan | DACS-MIB |
| 1.3.6.1.4.1.164.3.1 | wanGen | DACS-MIB |
| 1.3.6.1.4.1.164.3.1.6 | diverseIfWanGen | DACS-MIB |
| 1.3.6.1.4.1.164.3.1.6.1 | ethIf | DACS-MIB |
| 1.3.6.1.4.1.164.3.1.6.1.3 | ethIfOamCfm | RAD-MIB |
| 1.3.6.1.4.1.164.3.1.6.1.3.1 | radMepTable | RAD-MIB |
| 1.3.6.1.4.1.164.3.1.6.1.3.1.1 | radMepEntry | RAD-MIB |
| 1.3.6.1.4.1.164.3.1.6.1.3.1.1.31 | radMepTransmitLtmTargetIsMepId | RAD-MIB |