RAD-MIB :: prtExVcPbxTsMode

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsRAD-MIBprtExVcPbxTsMode

prtExVcPbxTsMode

Module: RAD-MIB

OID (symbolic): RAD-MIB::prtExVcPbxTsMode

OID (numeric): 1.3.6.1.4.1.164.3.2.3.2.15.4.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute indicates the usage, process and way of the specific PABX TS towards its destination: unused - the TS is not used (no processing, no destination). compressed - the TS is used, sent for compression to an internal port (for VF-PBX cards: 1..6 for of either the same card or a VF-PBX card of the same group). For VF-24/30/48/60 - 'compressed' represents 'compressed Voice' (to differentiate it from 'compressedCcs'). In this case, the TS is compressed by an internal port (1..8). transparent - the TS is used; no processing. It is sent directly for Bypass to a ML card the VF port/TS is linked to. compressedCcs - supported only by VF-24/30/48/60 cards. The TS is used; sent for compression to the CPU. mng - the TS is used for Management (this option is used when the external port is connected to another product that has to be managed via this dedicated TS. ccs1..ccs8 - supported only by VF-24/30/48/60 cards. Compressed TS that comes from a bundle of V5.1 or V5.2 PBX. ss7n1..ss7n8 - supported only by VF-24/30/48/60 cards. Compressed TS that comes from a bundle of V5.1 or V5.2 PBX. ss7n1 can work versus Vmux having prtExPh1MlTsType=ss7(6).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.2.3.2.15.4.1.5
snmpwalk -v2c -c public <target> RAD-MIB::prtExVcPbxTsMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.2.3.2.15.4.1.5.1
snmpget -v2c -c public <target> RAD-MIB::prtExVcPbxTsMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.164.3.2.3.2.15.4.1.5.1 i <value>

Start monitoring RAD Data Communications access/transmission/multiplexer equipment, entire product line (base enterprise MIB) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAD-MIB::prtExVcPbxTsMode OID value, configure state conditions and alerts, and monitor any RAD Data Communications access/transmission/multiplexer equipment, entire product line (base enterprise MIB) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.2muxHubDACS-MIB
1.3.6.1.4.1.164.3.2.3prtMuxDACS-MIB
1.3.6.1.4.1.164.3.2.3.2cnfgPrtMuxDACS-MIB
1.3.6.1.4.1.164.3.2.3.2.15prtVcPbxCnfgDACS-MIB
1.3.6.1.4.1.164.3.2.3.2.15.4prtExVcPbxTsTableDACS-MIB
1.3.6.1.4.1.164.3.2.3.2.15.4.1prtExVcPbxTsEntryDACS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.164.3.2.3.2.15.4.1.5prtExVcPbxTsModeRAD-MIB