All MIBs › RAD-MIB › prtBertResult
prtBertResult
Module: RAD-MIB
OID (symbolic): RAD-MIB::prtBertResult
OID (numeric): 1.3.6.1.4.1.164.3.3.3.1.5.1.13
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description:
This object indicates Result of BERT for the selected port (number of error bits divided to the total number of data bits.) Applicable only if BERT is running on this port
Agents that do not support this feature will send SIZE 0.
What is prtBertResult?
This object reports the results of a BERT (Bit Error Rate Test) that measures line quality on a selected port by counting erroneous bits as a ratio of total bits transmitted. The value represents the error rate as a fraction (e.g., 1 in 10,000 bits). Network technicians use BERT results to validate port health and identify problematic circuits before deploying production traffic.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.3.3.1.5.1.13 snmpwalk -v2c -c public <target> RAD-MIB::prtBertResult
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.3.3.1.5.1.13.1 snmpget -v2c -c public <target> RAD-MIB::prtBertResult.1
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.164 | rad | DACS-MIB |
| 1.3.6.1.4.1.164.3 | radWan | DACS-MIB |
| 1.3.6.1.4.1.164.3.3 | dacsMux | DACS-MIB |
| 1.3.6.1.4.1.164.3.3.3 | prtDacsMux | DACS-MIB |
| 1.3.6.1.4.1.164.3.3.3.1 | prtGen | DACS-MIB |
| 1.3.6.1.4.1.164.3.3.3.1.5 | prtBertTable | DACS-MIB |
| 1.3.6.1.4.1.164.3.3.3.1.5.1 | prtBertEntry | DACS-MIB |
| 1.3.6.1.4.1.164.3.3.3.1.5.1.13 | prtBertResult | RAD-MIB |